Loading...
HomeMy WebLinkAboutPermit M16-0072 - BOX LUNCH - DIFFUSER, DUCT BRANCH AND THERMOSTATBOX LUNCH 800 SOUTHCENTER MAIL M16-0072 City of Tukwila ' Department of Community Development • 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Inspection Request Line: 206-438-9350 Web site: http://www.TukwilaWA.gov MECHANICAL PERMIT Parcel No: 9202470010 Permit Number: M16-0072 Address: 800 SOUTHCENTER MALL Issue Date: 6/28/2016 Permit Expires On: 12/25/2016 Project Name: BOX LUNCH Owner: 2012 National Electrical Code: Name: WESTFIELD PROPERTY TAX DEPT 2012 Address: PO BOX 130940, CARLSBAD, MO, International Mechanical Code Edition: 2012 92013 2014 Contact Person: 2012 WA State Energy Code: Name: SAMANTHA IGOU Phone: (314) 415-2400 Address: 1950 CRAIG RD, STE 300, ST LOUIS, C MO, 63146 Contractor: 1 Name: RT STEVENS CONSTRUCTION INC Phone: (951) 280-9361 Address: 420 MCKINLEY #111-313, CORONA, CA, 92879 License No: RTSTESC885C7 Expiration Date: 5/1/2018 Lender: Name: Address: DESCRIPTION OF WORK: EXISTING SPLIT SYSTEM, EXISTING DUCT WORK, EXISTING DIFFUSERS/GRILLES TO REMAIN. EXISTING CEILING TO REMAIN. ADDING ONE DIFFUSER TO NEW FITTING ROOM WITH NEW DUCT BRANCH. RELOCATING ONE RETURN GRILLE IN SALES. REPLACING THERMOSTAT WITH NEW THERMOSTAT AND REMOTE SENSOR Valuation of Work: $15,000.00 Fees Collected: $389.62 Type of Work: REPLACEMENT Electrical Service Provided by: PUGEST SOUND ENERGY Fuel type: ELECT Water District: TUKWILA Sewer District: TUKWILA Current Codes adopted by the City of Tukwila: International Building Code Edition: 2012 National Electrical Code: 2014 International Residential Code Edition: 2012 WA Cities Electrical Code: 2014 International Mechanical Code Edition: 2012 WAC 296-466: 2014 Uniform Plumbing Code Edition: 2012 WA State Energy Code: 2012 International Fuel Gas Code: 2012 C Permit Center Authorized Signature: 1 Date: I hearby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this development permit and agree to the conditions attached to this permit. Signature:_ QGR - Date: in Print Name: G This permit shall become null and void if the work is not commenced within 180 days for the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. PERMIT CONDITIONS: 1: Work shall be installed in accordance with the approved construction documents, and any changes made during construction that are not in accordance with the approved construction documents shall be resubmitted for approval. 2: All permits, inspection record card and approved construction documents shall be kept at the site of work and shall be open to inspection by the Building Inspector until final inspection approval is granted. 3: All construction shall be done in conformance with the Washington State Building Code and the Washington State Energy Code. 4: Remove all demolition rubble and loose miscellaneous material from lot or parcel of ground, properly cap the sanitary sewer connections, and properly fill or otherwise protect all basements, cellars, septic tanks, wells, and other excavations. Final inspection approval will be determined by the building inspector based on satisfactory completion of this requirement. 5: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206-431-3670). 6: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center. 7: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. 8: `MECHANICAL PERMIT CONDITIONS' 9: All mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center (206/431-3670). 10: Manufacturers installation instructions shall be available on the job site at the time of inspection. PERMIT INSPECTIONS REQUIRED Permit Inspection Line: (206) 438-9350 1800 MECHANICAL FINAL 0701 ROUGH -IN MECHANICAL CITY OF TUKWILA Community Development Department Permit Center • 6300 Southcenter Blvd., Suite 100 Tukwila, 1,VA 98188 http://www.TukwilaWA.gov Mechanical Permit No. 0 I � --- 001 - Project No. Date Application Accepted: Date Application Expires: _ use MECHANICAL PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. "please print" SITE LOCATION DKing Co Assessor's Tax No.: Site Address: Southcenter Mall Suite Number: 228 Floor: Tenant Name: Box Lunch New Tenant: ® .....Yes ❑ ..No PROPERTY OWNER Name: Westfield Address: 633 Southcenter Mall City: S e a t t l e State: WA Zip: 98188 CONTACT PERSON — person receiving all project communication Name: Samantha Igou Address:1950 Craig Rd, Ste 300 City: St . Louis State: MO Zip:6314 6 Phone: 314-415-2400 Fax: 314-415-2300 Email:sigou@arcv.com Valuation of project (contractor's bid price): $ MECHANICAL CONTRACTOR INFORMATION Company Name: to be determined Address: City: State: Zip: Phone: Fax: Contr Reg No.: Exp Date: Tukwila Business License No.: Describe the scope of work in detail: Existing split system, existing duct work, existing diffusers/grilles to remain. Existing ceiling to remain. Adding one diffuser to new fitting room with new duct branch. Relocating one return grille in sales. Replacing thermostat with new thermostat and remote sensor Use: Residential: New .......... ❑ Replacement ........ ❑ Commercial: New .......... ❑ Replacement ........ FKI Fuel Type: Electric ..... ® Gas ....... ❑ Other: hea t pump w/ e 1 eptric h P a H:Wpplications\Fotms-Applications On Line\2011 Applicationswlechanical Permit Application Revised 9-9.1 l.docz Revised: August 2011 Page t of 2 bh Indicate type of mechanical work being installed and the quantity below: Unit Type Qty Furnace <100k btu Furnace >100k btu 1 Floor furnace 1 Suspended/wall/floor mounted heater Appliance vent Repair or addition to heat/refrig/cooling system Air handling unit <10,000 cfm Unit Type Qty Air handling unit >I 0 000 cfm Evaporator cooler 1 Ventilation fan connected to single duct 1 Ventilation system Hood and duct Incinerator — domestic Incinerator — comm/industrial PERMIT APPLICATION NOTES - Unit Type Qty Fire damper Diffuser 1 Thermostat 1 Wood/gas stove Emergency enerator Other mechanical equipment Boiler/Compressor E 0-3 hp/100,000 btu 3-15 h /500,000 btu 15-30 hp/1,000,000 btu 30-50 hp/1,750,000 btu 50+ hp/1,750,000 btu Value of construction — in all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the permit center to comply with current fee schedules. Expiration of plan review — applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The building official may grant one extension of time for additional periods not to exceed 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. OR AUTHORIZED AGENT: Print Mailing Address: Date: S. (.' ' 1 `0 Day Telephone:�l q -0 Is -QqW C ou cs Mo 10511-1 Co City State Zip H:Wpplications\Forms-Applications On Line\201 1 ApplicationsWechanical Permit Application Revised 8-9-1 Ldocx Revised: August 2011 Page 2 of 2 bh $2,559.79 PermitTRAK D16-0119 Address: 800 SOUTHCENTER MALL Apn: 9202470010 $1,680.93 $1,601.10 DEVELOPMENT R000.322.100.00.00 0.00 $1,596.60 f PERMIT FEE WASHINGTON STATE SURCHARGE B640.237.114 0.00 $4.50 $79.83 TECHNOLOGY FEE 11000.322.900.04.00 0.00 $79.83 TECHNOLOGY FEE EL16-0413 Address: 800 SOUTHCENTER MALL Apn: 9202470010 $564.17 $537.30 ELECTRICAL PERMIT FEE MULTI-FAM/COMM 8000.322.101.00.00 0.00 $537.30 $26.87 TECHNOLOGY FEE 8000.322.900.04.00 0.00 $26.87 -' TECHNOLOGY FEE M16-0072 Address: 800 SOUTHCENTER MALL Apn: 9202470010 $314.69 $299.70 MECHANICAL PERMIT ISSUANCE BASE FEE 8000.322.100.00.00 0.00 $32.50 ,-' PERMIT FEE 5000.322.100.00.00 0.00 $267.20 $14.99 TECHNOLOGY FEE 8000.322.900.04.00 0.00 $14.99 r TECHNOLOGY FEE ad, t .: I i City of Tukwila 6200 Southcenter Blvd, Tukwila, WA --•l i, i 1 Finance Departmentrn r" 1618001-1 06/26/2016 BR1 T121 Z 'T' f ,; Tue Jun28,2016 02:54PM Trans#14-16 =-,., 14 $2555.29 DCDGEN - DCD Permits PluM- - General Fund ID: RT STEVENS CONSTRUCTION' 115 $4.50 MISC - Miscellaneous Desc: WA ST SIJRCHARGE DCD PERMIT FEE 16 $67.00 BUSLCN - Business Licenses 4ft ' Customer#: 00068415 Activity# : 00025822 3 ITEM(S): TOTAL: $2626.79 Check (002233) PAID $2626.79 Date Paid: Tuesday, June 28, 2016 Paid By: RT STEVENS CONSTRUCTION INC wwwAukwilawa.gov 206-433-1835 -' Pay Method: CHECK 2233 -2�1•on244aPWAU*'ttai,-1W fffiNi Totl4a*� 1of SYSTEMS 1- 1 Tr-.r,—rri71--7iQf7 Q1FI17I T-Tr_O819T DESCRIPTIONS • QUANTITY PAID PermitTRAK $1,247.05 D16-0119 Address: 800 SOUTHCENTER MALL Apn: 9202470010 $1,037.79 DEVELOPMENT $1,037.79 PLAN CHECK FEE R000.345.830.00.00 0.00 $1,037.79 EL16-0413 Address: 800 SOUTHCENTER MALL Apn: 9202470010 $134.33 ELECTRICAL $134.33 PLAN CHECK FEE R000.345.832.00.00 0.00 $134.33 M16-0072 Address: 800 SOUTHCENTER MALL Apn: 9202470010 $74.93 MECHANICAL $74.93 PLAN CHECK FEE TOTALR8410 R000.322.102.00.00 0.00 $74.93 $1,247.05 Date Paid: Monday, May 09, 2016 Paid By: ARCVISION Pay Method: CHECK 34897 Printed: Monday, May 09, 2016 11:02 AM 1 of 1 (r7L! SYSTEMS INSPECTION RECORD r Retain a copy with permit�� INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Proje X nf�N Type of Inspection: C(I+ A)1(AL rA/ L Address: Date Called: 0 MALL Special Instructions: Date Want Requester: %71 Phone No: 977-- 0 9- 2367 ®Approved per applicable codes. Corrections required prior to approval. Inspector: /I_ Date: REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call. to schedule reinspection. INSPECTION RECORD INSPECTIONN0. Retain a copy with permit �lV PERMIT oZ CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Project:Ty RI2 y- e of Inspection: N Address: L Date Called: Special Instructions: Date Wanted: , m Z7 G p.m. Requester: Phone No: IKApproved per applicable codes. LJ Corrections required prior to approval. Iinspector: —" IDate: 7k7I10 REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. rt"RMiT COORD COPY PLAN REVIEW/ROUTING SLIP PERMIT NUMBER: M16-007 DATE: 05/16/16 PROJECT NAME: BOX LUNCH SITE ADDRESS: 800 SOUTHCENTER MALL X Original Plan Submittal Response to Correction Letter # Revision # before Permit Issued Revision # after Permit Issued DEPARTMENTS: - 4K, N//4- E- uilding Division Fire Prevention Planning Division Public Works ❑ Structural ❑ Permit Coordinator ❑ PRELIMINARY REVIEW: DATE: 05/17/16 Not Applicable ❑ Structural Review Required ❑ (n.o approval/review required) REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: DUE DATE: 06/09/16 Approved a Corrections Required ❑ (corrections entered in Reviews) Notation: REVIEWER'S INITIALS: Approved with Conditions Denied n (ie: Zoning Issues) DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: 12/18/2013 RT STEVENS CONSTRUCTION TNTC inWashington State Department of Labor & Industries Page 1 of 2 Horne Espanol Contact Search L&I A-7Index Help Tv�vU-I Safety & Health Claims & Insurance Workplace Rights Trades & Licensing RT STEVENS CONSTRUCTION INC Owner or tradesperson STEVENS, TROY JAMES Principals STEVENS, TROY JAMES, PRESIDENT STEVENS, PATRICIA, VICE PRESIDENT WA UBI No. License 420 MCKINLEY#111-313 CORONA, CA 92879 951-280-9361 Business type Verify the contractor's active registration / license / certification (depending on trade) and any past violations. Construction Contractor Active. ...................................................... . Meets current requirements. License specialties GENERAL License no. RTSTESC885C7 Effective — expiration 04/20/2012— 05/01/2018 Bond American Contractors Indem CO $12,000.00 Bond account no. 100187673 Received by L&I Effective date 03/19/2012 02/14/2012 Expiration date Until Canceled Insurance ..................... Ironshore Specialty Ins Co $1,000,000.00 Policy no. AGS0096000 Received by L&I Effective date 03/23/2016 03121/2016 Expiration date 03/21/2017 Insurance history Savings No savings accounts during the previous 6 year period. Lawsuits against the, bond or savings No lawsuits against the bond or savings accounts during the previous 6 year period. L&I Tax debts ............................... No L&I tax debts are recorded for this contractor license during the previous 6 year period, but some debts may be recorded by other agencies. License Violations No license violations during the previous 6 year period. https:Hsecure.Ini.wa.gov/verify/Detail.aspx?UBI=603094978&LIC=RTSTESC885C7&SAW= 6/28/2016 MECHANICAL CONTRACTORS TES- IT IS THE RESPONSIBILITY OF THE CONTRACTOR TO NOTIFY THE ARCHITECT, LANDLORD OR TENANT OF ANY DISCREPANCIES ENCOUNTERED ON THE PLANS OR IN EXISTING SITE CONDITIONS PRIOR TO SUBMISSION OF BID. BIDDERS ARE TO VISIT THE SITE AND FAMILIARIZE THEMSELVES WITH EXISTING CONDITIONS AND SATISFY THEMSELVES AS TO THE NATURE AND SCOPE OF THE WORK. THE BASE BID SHALL REFLECT MODIFICATIONS TO SYSTEMS AND DEVICES AS REQUIRED BY STATE, LOCAL AND FEDERAL CODES WHETHER INDICATED OR NOT ON CONTRACT DOCUMENTS. THE SUBMISSIONS OF A BID WILL BE EVIDENCE THAT SUCH AN EXAMINATION AND COMPLIANCE WITH GOVERNING CODES/REQUIREMENTS HAS BEEN MADE. LATER CLAIMS FOR LABOR, EQUIPMENT, OR MATERIALS REQUIRED, OR FOR DIFFICULTIES ENCOUNTERED WHICH COULD HAVE BEEN FORSEEN HAD AN EXAMINATION AND CODE/REQUIREMENTS REVIEW BEEN MADE, WILL NOT BE ALLOWED. THE OWNER RESERVES THE RIGHT TO CHECK CONSTRUCTION COMPLIANCE WITH PLANS AND SPECIFICATIONS. SHOULD THE OWNER FIND CORRECTIVE WORK TO BE NECESSARY, HE WILL NOTIFY CONTRACTOR OF SUCH WORK IN WRITING AND EXPECT COMPLIANCE PERFORMED WITH DUE DILIGENCE. IF ANY CORRECTIVE WORK IS DEEMED TO BE NECESSARY, THE COST OF RE -INSPECTIONS WILL BE BORNE BY THE CONTRACTOR. IF WORK IS REQUIRED BY OWNER IN ORDER TO IMPROVE, CHANGE OR CORRECT AIR CONDITIONING OPERATIONAL CONDITIONS DUE TO: PART MALFUNCTION, WARRANTY OR OTHER INABILITY TO PROVIDE THE COMFORT CONDITIONS REQUIRED BY THE STORE, CONTRACTOR SHALL BE DIRECTED BY OWNER, TO ADDRESS THIS WORK IN A TIMELY MANNER. IF IT BECOMES EVIDENT THAT THE CONTRACTOR CAN NOT ACCOMPLISH THE TASK, THEN AFTER 72 HOURS OF WRITTEN NOTICE, THE OWNER MAY AT HIS DISCRETION TAKE OVER SUCH WORK AND BACKCHARGE THE CONTRACTOR FOR ANY CORRECTIVE WORK THAT WAS REQUIRED DUE TO LACK OF PERFORMANCE, WORKMANSHIP AND/OR ADHERENCE TO PLANS AND SPECIFICATIONS. REUSEOF EXISTING EWIPMENT 1. EXISTING AIR CONDITIONING EQUIPMENT SHALL BE REUSED AS INDICATED ON THE DRAWINGS. POINTS OF SERVICE SHALL INCLUDE, BUT NOT BE LIMITED TO, THE FOLLOWING: 2. REMOVE EXISTING AIR FILTERS AND REPLACE WITH NEW PLEATED AIR FILTERS. THOROUGHLY CLEAN ALL INTAKE LOUVERS OR SCREENS AND BOTH SIDES OF EVAPORATOR AND CONDENSING COILS. 3. CHECK ALL BELTS FOR WEAR, ALIGNMENT AND PROPER TENSION (ADJUST AND REPLACE AS NEEDED). 4. TIGHTEN MOTOR MOUNTS AS REQUIRED. 5. INSPECT AND LUBRICATE MOTORS, BEARINGS, AND SHAFTS AS PER MANUFACTURERS REQUIREMENTS. 6. INSPECT REFRIGERANT SYSTEM FOR LEAKS AND PROPER CHARGE, REPAIR LINES AND ADD REFRIGERANT IF NECESSARY. INSPECT FILTER/DRYER AND REPAIR/REPLACE AS REQUIRED. INSPECT INSULATION ON SUCTION LINE AND REPLACE AS NEEDED. 7. THOROUGHLY CLEAN INTERIOR of UNIT, INCLUDING COILS, CONDENSATE DRAIN PAN(VERIFY DRAINS PROPERLY), BLOWER WHEEL, AND DAMPER BLADES. 8. CONTRACTOR MAY CLEAN AND REUSE EXISTING DUCTWORK, SUPPLY AIR DIFFUSER, AND RETURN AIR GRILLE IF THEY ARE IN GOOD CONDITION AND MATCH THE SIZE AND SPECIFICATIONS OF WHAT IS CALLED OUT ON THESE CONSTRUCTION DOCUMENTS. 9. CONTRACTOR SHALL PROVIDE NEW DUCTWORK AND SUPPLY DIFFUSERS AS NECESSARY TO SATISFY THE INTENT OF THESE DRAWINGS. 10. ENTIRE HVAC SYSTEM SHALL CONFORM TO THE EXISTING BUILDING CONSTRUCTION AND ALL APPLICABLE STATE AND LOCAL CODES AND ALL LANDLORD CRITERIA. 11. THE MECHANICAL CONTRACTOR MUST VERIFY ALL EXISTING CONDITIONS AND SERVICES AT THE JOB SITE, 12. ALL WORK SHALL BE SCHEDULED SO AS NOT TO INTERRUPT THE NORMAL OPERATION OF OTHER CONTRACTORS. 13. VERIFY AND RESET 0/A THRU AIR HANDLING UNIT TO SPACE AS SCHEDULED. 14. ALL WORK, EQUIPMENT AND ACCESSORIES TO BRING EXISTING SYSTEM TO GOOD WORKING CONDITION SHALL BE COVERED UNDER CONTRACTOR'S ORIGINAL BID AND AT NOT ADDITIONAL EXPENSE. CONTRACTOR SHALL VERIFY ALL ON SITE CONDITIONS PRIOR TO BID. BMW M HANDILM HVAC SYMBOLS LE UNIT SCHEDULE -1) , ® SUPPLY AIR DIFFUSER SD SMOKE DETECTOR Z RETURN AIR GRILLE R.A.G. RETURN AIR GRILLE O.A. OUTDOOR AIR DIFF. DIFFUSER R.A. RETURN AIR M.D. MANUAL DAMPER S.A. SUPPLY AIR F.D. FIRE DAMPER TE TOILET EXHAUST F.C. FLEXIBLE CONNECTION �M MOTORIZED DAMPER S.E. SMOKE EXHAUST OS SMOKE DETECTION DEVICEAIR DEVICE TYPE QT THERMOSTAT WB AIR VOLUME IN CUBIC FEET/MINUTE (CFM) QS TEMPERATURE SENSOR L_ DAMPER BMW M HANDILM MANUFACTURER UNIT SCHEDULE -1) O MANUFACTURER MODEL N0. PH VOLTS HZ PH MCA MIN. OUTSIDE AIR CFM TOTAL CFM SIZE (TONS) BASE UNIT WEIGHT TRANE TWE09OD300AA 34.4 208 60 3 *45.7 480 2,700 7.5 323 LBS ENTERING AIR LEAVING AIR COOLING COIL 68.1 MBH EVAP. FAN MOTOR ELECTRIC HEAT FILTERS SUPPORTS PER S.M.A.C.N.A. (TYPICAL). USE FLEXIBLE DUCT FOR FINAL RUNOUT TO DB WB DB WB FACE ROWS FINS INCH NO. SIZE TYPE 78.4 66.4 64.8 61.9 S8*1 4 14 1.5 HP *11.24 KW 3 16x25x1 T/A ACCESSORIES: EXISTING TO REMAIN. ENSURE IN GOOD WORKING ORDER. * FIELD VERIFY IF THERE IS AN EXISTING ELECTRIC HEATER AND KW. VERIFY EXISTING MCA. EXISTING T PUW UNIT SCH (HPICU-1) MANUFACTURER MODEL NO. O REFRIG. VOLTAGE PH HZ MCA SIZE (TONS) NET MAX UNIT WEIGHT TRANE TWA090D30RAA R-41 OA 208 3 60 34.4 7,5 340 LBS LIQUID LINE SUCTION LINE COMBINED COOLING CAPACITY EER HEATPUMP CAPACITY HEATING OUTPUT REMARKS SEE BELOW TOTAL SENSIBLE 6" RD 1-3/8" 94.7 MBH 68.1 MBH 11.0 47.7 I MBH N/A ACCESSORIES: EXISTING TO REMAIN. ENSURE IN GOOD WORKING ORDER. * OR APPROVED EQUAL EXIST. i HPCU-1 i C + SM1NIQ59 KEYED O PLAN QTY' 13 *TITUS FACE NECK FLEX TYPE NOTES MARK ...........:...::.4:j�...o# ;-•..; PATH DIMENSIONS. HOLD ALL DUCTWORK AS HIGH AS POSSIBLE/PRACTICAL. CONNECT MODEL NO. SIZE SIZE SIZE Oi..'_M...:.:... m.: #....v n.w ................ »1.:.......li A 1 O2 TDCA 12"x12" 6" RD 6" RD DIFF. 1,2,3,4 FLEXIBLE DUCT, MAXIMUM LENGTH 5'-0". PROVIDE SMOOTH TRANSITIONS AND PROPER U CD3 W Z Yw U W S 1 � Lo SUPPORTS PER S.M.A.C.N.A. (TYPICAL). USE FLEXIBLE DUCT FOR FINAL RUNOUT TO O3 EXISTING SPRINKLER HEAD TO REMAIN. FIELD VERIFY EXACT LOCATION. SPRINKLER O ; CEILING MOUNT DIFFUSER ONLY. REFER TO SCHEDULE FOR FLEXIBLE DUCT SIZES. NOTES: 1. DIFFUSERS TO HAVE 4 -WAY THROW UNLESS NOTED 2. PROVIDE TRIM (TRM) RING FOR GYPSUM BOARD CEILING FOR CONCEALED SPRINKLER HEADS IN SALES AREA. VERIFY THAT HEADS ARE ABLE TO15 3. PROVIDE & INSTALL MANUAL VOLUME DAMPER 4. SURFACE MOUNTED. PAINT TO MATCH CEILING. * OR APPROVED EQUAL EXIST. i HPCU-1 i (NP) C + SM1NIQ59 KEYED TES O O1 EXISTING HVAC EQUIPMENT, DUCTWORK, HANGERS, ASSOCIATED CONTROLS, ETC. NOT 13 NEW LOW PRESSURE AIR DUCT SUPPLIED & INSTALLED BY MECHANICAL CONTRACTOR. as SCHEDULED TO BE RELOCATED OR RE -USED SHALL BE DISCONNECTED AND REMOVED f PROVIDE TRANSITIONS AS REQUIRED. DUCT SIZES SHOWN ARE CLEAR INTERNAL AIR o: y .,ail FROM JOB SITE. DO NOT JUST ABANDON. FIELD VERIFY EXACT CONDITIONS AND ...........:...::.4:j�...o# ;-•..; PATH DIMENSIONS. HOLD ALL DUCTWORK AS HIGH AS POSSIBLE/PRACTICAL. CONNECT t LOCATIONS PRIOR TO SUBMITTING A BID. � TO EXISTING DUCTWORK AS REQUIRED. REFER TO MECHANICAL SPECS FOR ADDITIONAL Oi..'_M...:.:... m.: #....v n.w ................ »1.:.......li i. INFORMATION, SHEET M3. O2 EXISTING 4" SPRINKLER MAIN @ 14'-6" A.F.F. FIELD VERIFY LOCATION, SIZE, AND Z ROUTING. 14 FLEXIBLE DUCT, MAXIMUM LENGTH 5'-0". PROVIDE SMOOTH TRANSITIONS AND PROPER U CD3 W Z Yw U W S 1 � Lo SUPPORTS PER S.M.A.C.N.A. (TYPICAL). USE FLEXIBLE DUCT FOR FINAL RUNOUT TO O3 EXISTING SPRINKLER HEAD TO REMAIN. FIELD VERIFY EXACT LOCATION. SPRINKLER O ; CEILING MOUNT DIFFUSER ONLY. REFER TO SCHEDULE FOR FLEXIBLE DUCT SIZES. CONTRACTOR TO REMOVE EXISTING WHITE CAP AND REPLACE WITH NEW BLACK CAP FOR CONCEALED SPRINKLER HEADS IN SALES AREA. VERIFY THAT HEADS ARE ABLE TO15 INSTALL MANUAL VOLUME DAMPER AT BRANCH DUCT TAKE -OFF (TYPICAL). HAVE INTERCHANGEABLE CAPS, IF NOT COORDINATE WITH BOX LUNCH P.M. PRIOR TO REPLACING WHITE CAPS WITH BLACK ONES. 16 EXISTING SMOKE DETECTION DEVICE LOCATED IN RETURN AIR DUCT. ENSURE DEVICE IS INTERLOCKED WITH HVAC UNIT SO AS TO SHUT THE UNIT DOWN UPON THE DETECTION ®PROVIDE NEW SPRINKLER HEAD. COORDINATE WITH NEW LIGHTS, CEILING, AND OF SMOKE. ACTIVATION OF A SMOKE DETECTOR SHALL ACTIVATE A VISIBLE AND DUCTWORK AS REQUIRED. MODIFY SUPPLY PIPING AS REQUIRED.. REFER TO MECHANICAL AUDIBLE SIGNAL IN AN APPROVED LOCATION. DUCT SMOKE DETECTOR TROUBLE SPECIFICATIONS FOR SPRINKLER HEAD TYPE. CONDITIONS SHALL ACTIVATE A VISIBLE OR AUDIBLE SIGNAL IN AN APPROVED LOCATION AND SHALL BE IDENTIFIED AS AIR DUCT DETECTOR TROUBLE. COORDINATE WITH O5 EXISTING AIR HANDLING UNIT @ 11'-S" A.F.F. TO REMAIN. CONTRACTOR TO CLEAN LANDLORD'S DESIGNATED FIRE ALARM CONTRACTOR FOR ALL DEVICES CONTROLS AND COILS, LUBRICATE MOTOR, ADJUST/REPLACE BELTS, CHANGE FILTERS, REPAIR LEAKS, PROGRAMMING REQUIRED. PROVIDE NEW IF REQUIRED. FIELD VERIFY EXISTING AND PROVIDE GENERAL MAINTENANCE AS REQUIRED. ADVISE BOX LUNCH'S ON-SITE CONDITION. REP. OF ANY DEFICIENCIES PRIOR TO MAKING REPAIRS. ADJUST CONTROLS PER MANUFACTURER'S DIRECTIONS. FIELD VERIFY EXACT LOCATION AND CONDITIONS PRIOR 17 EXISTING OUTSIDE AIR DUCT TO REMAIN. FIELD VERIFY EXACT LOCATION AND SIZE. TO SUBMITTING BID. REFER TO SCHEDULE FOR ADDITIONAL INFORMATION. CLEAN, REPAIR/REPLACE AND RE -INSULATE AS REQUIRED. © EXISTING AIR COOLED CONDENSING UNIT LOCATED ON ROOF TO REMAIN. MECHANICAL 1 g EXISTING MIXING BOX TO REMAIN. CONTRACTOR IS TO CLEAN AIR INTAKE, INSPECT FOR LEAKS, ADD REFRIGERANT AS REQUIRED PER MANUFACTURER'S SPECIFICATIONS, AND PROVIDE GENERAL MAINTENANCE. 19 EXISTING LINEAR SLOT SUPPLY AIR DIFFUSER TO REMAIN. FIELD VERIFY._ EXACT ADVISE BOX LUNCH'S ON-SITE REPRESENTATIVE OF ANY DEFICIENCIES PRIOR TO LOCATION AND CONDITION. CLEAN, REPAIR/REPLACE, AND PAINT TO MATCH ADJACENT-­ DJACENT_.MAKING MAKINGREPAIRS. FIELD VERIFY EXACT LOCATION AND CONDITION PRIOR TO SUBMITTING CEILING AS REQUIRED. BID. REFER TO SCHEDULE FOR ADDITIONAL INFORMATION. 20 EXISTING RETURN AIR GRILLE TO REMAIN. FIELD VERIFY EXACT LOCATION AND O7 EXISTING REFRIGERANT SUPPLY AND RETURN LINES TO REMAIN. FIELD VERIFY EXACT CONDITION. CLEAN, REPAIR/REPLACE, AND PAINT TO MATCH ADJACENT CEILING AS SIZES, LOCATIONS AND CONDITION. REPAIR/REPLACE AND RE -INSULATE AS REQUIRED. REQUIRED. ® EXISTING CONDENSATE DRAIN LINE TERMINATING AT FLOOR DRAIN IN TOILET ROOM TO 21 EXISTING RETURN AIR GRILLE TO BE RELOCATED TO ACCOMMODATE NEW CEILING AND REMAIN. FIELD VERIFY EXACT LOCATION. ENSURE ROUTING PER LANDLORD'S LIGHTS. PAINT TO MATCH ADJACENT CEILING AS REQUIRED. SPECIFICATIONS. ENSURE P -TRAP AND PROPER AIR GAP PER CODE. INSULATE AS REQUIRED, �2 EXISTING TOILET EXHAUST FAN AND DUCT SYSTEM TO REMAIN. CONTRACTOR SHALL INSPECT, PERFORM GENERAL MAINTENANCE, AND CLEAN AS REQUIRED. FIELD VERIFY O9 HVAC CONTRACTOR TO PROVIDE AND INSTALL NEW PROGRAMMABLE HEATING AND EXACT LOCATION AND CONDITION. COOLING THERMOSTAT. TOP OF THERMOSTAT TO BE MOUNTED AT 46.5" ABOVE FINISHED FLOOR IN LOCATION (NEAR STOCK ROOM DESK) SHOWN ON PLAN. COORDINATE EXACT �3 ENSURE TOILET ROOM DOOR IS UNDERCUT 3/4" (MIN.) TO FACILITATE AIR FLOW. MOUNTING LOCATION WITH BOX LUNCH PM PRIOR TO INSTALL. FAILURE TO DO SO MAY COORDINATE WITH GENERAL CONTRACTOR. RESULT IN HVAC CONTRACTOR RELOCATING T -STAT TO APPROVED LOCATION AT HVAC CONTRACTOR'S SOLE COST. THERMOSTAT' MUST BE FULLY COMPATIBLE WITH HVAC UNIT EXISTING MALL DUCT IN SPACE TO REMAIN. SHOWN FOR REFERENCE. AVOID WITH NEW USED FOR PROJECT. REFER TO M3 FOR ADDITIONAL INFORMATION. CONSTRUCTION. 10 REMOTE TEMPERATURE SENSOR FOR THERMOSTAT MOUNTED 5 FT ABOVE FINISHED 25 EXISTING EXHAUST DUCT @ 13'-0" A.F.F. TO REMAIN. SHOWN FOR REFERENCE. AVOID FLOOR. REFER TO PLAN FOR DIMENSION OFF EDGE OF WALL. COORDINATE EXACT WITH NEW CONSTRUCTION. MOUNTING LOCATION WITH BOX LUNCH PM PRIOR TO INSTALL. FAILURE TO DO SO MAY RESULT IN HVAC CONTRACTOR RELOCATING SENSOR TO APPROVED LOCATION AT HVAC2�6 EXISTING 1" DOMESTIC COLD WATER LINE @ 13'-0" A.F.F. TO REMAIN. SHOWN FOR CONTRACTOR'S SOLE COST. REFERENCE. AVOID WITH NEW CONSTRUCTION. 11 EXISTING SUPPLY AIR DUCTWORK TO REMAIN. FIELD VERIFY EXACT LOCATIONS. DUCT 27 EXISTING 1" DOMESTIC COLD WATER LINE @ 10'-4" A.F.F. TO REMAIN. SHOWN FOR DIMENSIONS ARE CLEAR INTERNAL AIR PATH DIMENSIONS. PATCH/REPAIR/SEAL AIR REFERENCE. AVOID WITH NEW CONSTRUCTION. TIGHT/REPLACE, AND PROVIDE NEW INSULATION AS REQUIRED. REFER TO M3 FOR 28 EXISTING TOILET ROOM AND PLUMBING FIXTURES TO REMAIN. CLEAN/REPAIR/REPLACE ADDITIONAL INFORMATION. AS REQUIRED. FIELD VERIFY EXISTING CONDITIONS. 12 EXISTING RETURN AIR DUCTWORK WITH OPEN ENDED AIR DUCT TO REMAIN. FIELD VERIFY EXACT LOCATIONS. ENSURE SCREEN OVER OPENING. PROVIDE NEW INSULATION AS REQUIRED. REFER TO M3 FOR ADDITIONAL INFORMATION. (NP) .. ..... ... ................... ....... ......... ... .... .... ...........RLE�C�Opy .............. .... .. Pe -mit No. Ei al'u��nt�l ia �ubioof to 9i'I'ot9 and !¢ i171j?. C3 `C f SPe ii�t� documents ftm no-& P f 1 �dpy pq �d Qe..9 • F 01 E i v d s p i' r c a • ; �` � Copy HliG Ca�ri�sl.:?C� :� is �i,ietl%�ii'e�6 s��t�: OL P1 A" MECHAm Lr%[N Data: L -),E City of Tukwila BUILDING DIVISION Yom,: 5 J :FOR: as F f I as Piping o: y .,ail ukhvila ...........:...::.4:j�...o# ;-•..; ............. ;...:-:.r.c.rcl..tZ!\aflCtAtkt. .. ..... ... ................... ....... ......... ... .... .... ...........RLE�C�Opy .............. .... .. Pe -mit No. Ei al'u��nt�l ia �ubioof to 9i'I'ot9 and !¢ i171j?. C3 `C f SPe ii�t� documents ftm no-& P f 1 �dpy pq �d Qe..9 • F 01 E i v d s p i' r c a • ; �` � Copy HliG Ca�ri�sl.:?C� :� is �i,ietl%�ii'e�6 s��t�: OL P1 A" MECHAm Lr%[N Data: L -),E City of Tukwila BUILDING DIVISION Yom,: 5 as F f Q_ o: y .,ail O t ... � - Oi..'_M...:.:... m.: A REVIEWED FOR 00'0:,COMPLIANCE `. APPROVED MAY 2 4 2416 Atatty df Tuim to SUILDI C DIVISIO IIr CITY OF TUKWILA Wi 0 9 2016 PERMIT CENTER o 0 !.I 5 as F f Q_ o: y .,ail F 1 � f t � Oi..'_M...:.:... m.: #....v n.w ................ »1.:.......li i. U CD Y O N 1 Z m Q S 5 O ' ` (V1 U CD3 W Z Yw U W S 1 � Lo W cn O ; HEATING. VENTILATING AND AIR CONDITIONING GENERAL A. THE WORK COVERED BY THIS SECTION OF THESE SPECIFICATIONS SHALL BE ACCOMPLISHED IN ACCORDANCE WITH THE RESPECTIVE DRAWINGS, INFORMATION OR INSTRUCTIONS TO BIDDERS, GENERAL CONDITIONS, ADDENDA, OR DIRECTIVES WHICH MAY BE ISSUED BY THE OWNER, SHALL BE COMPLIED WITH IN EVERY ASPECT. B. THE LISTING HEREIN OF AN ARTICLE OR MATERIAL, OPERATION OR METHOD, REQUIRES THAT THE CONTRACTOR SHALL FURNISH AND INSTALL EACH ITEM LISTED, UNLESS SPECIFICALLY NOTED TO THE CONTRARY. THE CONTRACTOR SHALL PERFORM EACH OPERATION PRESCRIBED OR LISTED ACCORDING TO THE CONDITIONS STATED. C. REFERENCE IS MADE TO REQUISITES FOR BIDDERS AND CONTRACTORS UNDER OTHER SECTIONS OF THESE SPECIFICATIONS, WHICH SHALL BE CONSIDERED BINDING, UNLESS OTHERWISE NOTED UNDER THIS SECTION. SCOPE A. EACH CONTRACTOR SHALL THOROUGHLY ACQUAINT HIMSELF WITH THE CONSTRUCTION DETAILS, BOTH ON TENANT CONSTRUCTION DRAWINGS AND LANDLORD'S AS REFERRED TO, BEFORE SUBMITTING HIS BID AS NO ALLOWANCES WILL BE MADE BECAUSE OF CONTRACTOR'S UNFAMILIARITY WITH THESE DETAILS. B. ALL PERFORMANCE OF CONSTRUCTION SHALL BE AS REQUIRED BY THE PACE OF THE GENERAL CONSTRUCTION. FU RNISH ALL MATERIALS, EQUIPMENT, AND LABOR NECESSARY FOR A COMPLETE AND FULLY OPERATIONAL HEATING, VENTILATING, AND AIR CONDITIONING SYSTEM EXCEPT AS SPECIFICALLY EXCLUDED BY DRAWINGS AND/OR BY TENANT'S DIRECTIONS. INSPECTION OF SITE A. ALL PROPOSALS SHALL PRECLUDE THAT CONTRACTOR IS FAMILIAR WITH JOBSITE CONDITIONS AND UTILITY LOCATIONS AND THE LACK OF SPECIFIC INFORMATION ON THE DRAWINGS SHALL NOT RELIEVE THE CONTRACTOR OF ANY RESPONSIBILITY. B. ALL CONTRACTORS SUBMITTING PROPOSALS FOR THIS WORK SHALL FIRST EXAMINE THE SITE AND ALL EXISTING CONDITIONS AFFECTING HIS WORK. ALL PROPOSALS SHALL SPECIFY, IN WRITING, ALL SUCH CONDITIONS THAT MAY ALTER OR AFFECT THE WORK UNDER THIS CONTRACT. PERMITS ALL PERMITS AND LICENSES NECESSARY FOR THE PROPER EXECUTION OF THE WORK SHALL BE SECURED AND PAID FOR BY THE SUBCONTRACTOR INVOLVED. CODE REQUIREMENTS EACH SUBCONTRACTOR SHALL COMPLY WITH ALL LAWS, ORDINANCES, RULES AND REGULATIONS BEARING ON THE CONDUCT OF THE WORK AS DRAWN AND SPECIFIED. IF A SUBCONTRACTOR OBSERVES THAT THE DRAWINGS AND SPECIFICATIONS ARE AT A VARIANCE, HE SHALL PROMPTLY NOTIFY THE GENERAL CONTRACTOR AND THE TENANT IN WRITING. IF ANY SUBCONTRACTOR PERFORMS ANY WORK KNOWING IT TO BE CONTRARY TO LAWS, ORDINANCES, RULES AND REGULATIONS AND WITHOUT GIVING SUCH NOTICE, THE SUBCONTRACTOR SHALL BEAR ALL COSTS ARISING THEREFROM. MATERIALS AND WORKMANSHIP A. ALL MANUFACTURED ARTICLES, MATERIALS, AND EQUIPMENT SHALL BE APPLIED AS RECOMMENDED BY THE MANUFACTURERS, AND UNLESS OTHERWISE SPECIFIED SHALL BE NEW, AND FREE FROM ANY AND ALL DEFECTS. LIKE MATERIALS USED SHALL BE OF THE SAME MANUFACTURE AND QUALITY UNLESS OTHERWISE SPECIFIED. B. ALL WORK UNDER THIS CONTRACT SHALL BE PERFORMED BY COMPETENT WORKMEN AND EXECUTED IN A NEAT AND WORKMANLIKE MANNER. WORK SHALL BE PROPERLY PROTECTED DURING CONSTRUCTION AND COMPLETION, INSTALLATION SHALL BE THOROUGHLY CLEANED OF ALL DEBRIS PRESENT AS A RESULT OF THIS CONTRACT AND SHALL BE REMOVED FROM THE PREMISES, DO NOT ABANDON. C. MANUFACTURERS ARE LISTED ON PLANS TO ESTABLISH A STANDARD. THE PRODUCTS OF OTHER MANUFACTURERS WILL BE ACCEPTABLE, IF IN THE OPINION OF THE TENANT, THE SUBSTITUTE MATERIAL IS OF / QUALITY EQUAL TO OR BETTER THAN THE MATERIAL SPECIFIED, AND WILL SERVE WITH EQUAL EFFICIENCY AND DEPENDABILITY, FOR THE PURPOSE OF WHICH THE ITEMS SPECIFIED WERE INTENDED. ALL SUBSTITUTION REQUESTS SHALL BE SUBMITTED TO THE TENANT'S REPRESENTATIVE FOR APPROVAL PRIOR TO ORDERING. PROTECTION OF WORK AND PROPERTY A. EACH SUBCONTRACTOR SHALL CONTINUOUSLY MAINTAIN ADEQUATE PROTECTION OF ALL HIS WORK FROM DAMAGE AND SHALL PROTECT THE OWNER'S PROPERTY FROM INJURY OR LOSS ARISING FROM HIS WORK. ANY SUCH DAMAGE, INJURY, OR LOSS, EXCEPT SUCH AS MAY BE DIRECTLY DUE TO CAUSES BEYOND HIS CONTROL AND NOT TO HIS FAULT OR NEGLIGENCE, SHALL BE THE RESPONSIBILITY OF THE SUBCONTRACTOR. HE SHALL ADEQUATELY PROTECT ADJACENT PROPERTY AS WELL. r B. EACH SUBCONTRACTOR SHALL TAKE ALL NECESSARY PRECAUTIONS FOR THE SAFETY OF THEIR EMPLOYEES ON THE WORK AND SHALL COMPLY WITH ALL PROVISIONS OF FEDERAL, STATE AND LOCAL BUILDING CODES AND SAFETY LAWS TO PREVENT ACCIDENTS OR INJURY TO PERSONS ON OR ADJACENT TO THE PREMISES WHERE THE WORK IS BEING PERFORMED. EACH SUBCONTRACTOR SHALL MAINTAIN ALL INSURANCE REQUIRED TO PROTECT HIMSELF, THE OWNER AND TENANT FOR THE DURATION OF THE WORK AGAINST PROPERTY DAMAGE AND PUBLIC LIABILITY. CHANGES IN THE WORK THE TENANT, WITHOUT INVALIDATING THE CONTRACT, MAY ORDER EXTRA WORK OR MAKE CHANGES BY ALTERING, ADDING TO, OR DEDUCTING FROM THE WORK, WITH CONTRACT SUM BEING ADJUSTED ACCORDINGLY. COOPERATION ALL WORK UNDER THESE SPECIFICATIONS SHALL BE ACCOMPLISHED IN CONJUNCTION WITH OTHER CONTRACTORS AND TRADES OF THIS PROJECT IN A MANNER WHICH WILL ALLOW EACH CONTRACTOR AND TRADE SUFFICIENT TIME AT THE PROPER STAGE OF CONSTRUCTION TO FULFILL HIS CONTRACTS. CONTRACTORS SHALL CONTACT OWNER FOR INSTRUCTIONS SHOULD ANY QUESTIONS ARISE BETWEEN TRADES AS TO THE INSTALLATION OF LINES, DUCTS, CONDUITS, FIXTURES, OR EQUIPMENT, OR SHOULD IT APPEAR DESIRABLE TO ANY GENERAL CONSTRUCTION WHICH WOULD AFFECT THE APPEARANCE OR STRENGTH OF THE STRUCTURE. DRAWINGS AND SPECIFICATIONS A. THE DRAWINGS DIAGRAMMATICALLY INDICATE THE LOCATIONS OF THE VARIOUS LINES, DUCTS, CONDUITS, FIXTURES, AND EQUIPMENT AND THE METHOD OF CONNECTING AND CONTROLLING THEM. IT IS NOT INTENDED TO SHOW EVERY CONNECTION IN DETAIL AND ALL FITTINGS REQUIRED FOR A COMPLETE SYSTEM. B. SHOULD ANY CHANGES BE DEEMED NECESSARY BY THE CONTRACTOR, TO ANY ITEMS SHOWN ON CONTRACT DRAWINGS, SHOP DRAWINGS, DESCRIPTIONS, AND THE REASON FOR THE PROPOSED CHANGES SHALL BE SUBMITTED TO THE OWNER FOR APPROVAL. DRAWINGS AND SPECIFICATIONS (CONTINUED) C. SHOP DRAWINGS AND CATALOG DATA ON ALL MAJOR ITEMS OF EQUIPMENT AND SYSTEMS, AND OTHER SUCH ILLUSTRATIVE MATERIAL THAT MAY BE CONSIDERED NECESSARY BY THE TENANT, SHALL BE SUBMITTED BY THIS CONTRACTOR IN ADEQUATE TIME TO PREVENT DELAY AND/OR CONSTRUCTION MODIFICATIONS. RESPONSIBILITY A. THE CONTRACTOR WILL BE HELD RESPONSIBLE FOR THE SATISFACTORY AND COMPLETE EXECUTION OF ALL WORK INCLUDED IN HIS CONTRACT. HE SHALL PRODUCE COMPLETE AND FULLY OPERATIONAL SYSTEMS AND PROVIDE ALL INCIDENTAL ITEMS REQUIRED AS PART OF HIS WORK, REGARDLESS OF WHETHER SUCH ITEM IS PARTICULARLY SPECIFIED OR INDICATED. FOR EXAMPLE, ON SINK INSTALLATIONS, ESCUTCHEONS SHALL BE PROVIDED FOR COUNTERTOP PENETRATIONS, ALTHOUGH THEY WERE NOT SPECIFICALLY IDENTIFIED IN THE CONTRACT DOCUMENTS. B. CONTRACTOR SHALL SUPPLY TO LANDLORD AND TENANT A CERTIFIED AIR BALANCE REPORT AT COMPLETION OF PROJECT. THIS SHALL BE REQUIRED FOR BOTH REMODELED AND NEW STORES. DUCTWORK A. SQUARE/RECTANGULAR/ROUND CONCEALED ROUND DUCTWORK SHALL BE CONSTRUCTED OF NEW GALVANIZED PRIME GRADE SHEET STEEL. B. EXPOSED ROUND DUCTWORK SHALL BE SPIRAL AND CONSTRUCTED OF NEW GALVANIZED PRIME GRADE SHEET STEEL. C. ALL 90 DEGREE ELBOWS FOR ROUND DUCTWORK SHALL BE FIVE (5) PIECE. D. ALL LONGITUDINAL SEAMS SHALL BE FORMED BY PITTSBURGH, DRIVE SUP OR HEMMED S SLIP LOCKS. E. ALL JOINTS, LONGITUDINAL AND TRANSVERSE SEAMS, AND CONNECTIONS IN DUCTWORK MUST BE SECURELY SEALED USING WELDMENTS; MECHANICAL FASTENERS WITH SEALS, GASKETS, OR MASTICS; MESH AND MASTIC SEALING SYSTEMS; OR TAPES. TAPES AND MASTICS MUST BE LISTED AND LABELED IN ACCORDANCE WITH UL181A OR UL181 B. ALL LONGITUDINAL AND TRANSVERSE JOINTS, SEAMS AND CONNECTIONS OF SUPPLY AND RETURN DUCTS OPERATING AT STATIC PRESSURES LESS THAN OR EQUAL TO 2" W.G. SHALL BE SECURELY FASTENED AND SEALED WITH WELDS GASKETS, MASTICS (ADHESIVES), MASTIC -PLUS -EMBEDDED FABRIC SYSTEMS OR TAPES INSTALLED IN ACCORDANCE WITH MANUFACTURER'S INSTALLATION INSTRUCTIONS. F. JOINTS SHALL BE SWAGGED WITH ONE-HALF INCH (1/2") OVERLAP. G. ALL CONCEALED SUPPLY AIR DUCTS, CONCEALED RETURN AIR DUCTS AND ALL OUTSIDE AIR DUCTS SHALL BE INSULATED WITH 2.5" (R=6.0) THICK (MINIMUM) EXTERNAL ACOUSTICAL AND THERMAL INSULATION WHEN LOCATED IN UNCONDITIONED SPACE. H. DUCTWORK LOCATED IN OPEN TO DECK CONDITIONED SPACE DOES NOT REQUIRE INSULATION. I. FLEXIBLE AIR DUCT FOR CONNECTIONS BETWEEN MAIN DUCTS AND AIR DEVICES SHALL BE AIR DUCT LISTED BY UNDERWRITERS LABORATORIES UNDER UL STANDARD 181 AS A CLASS 1 FLEXIBLE AIR DUCT AND COMPLY WITH NFPA STANDARDS 90A AND 90B. FLEXDUCT SHALL BE FACTORY MADE AND COMPOSED OF A CPE LINER DUCT PERMANENTLY BOUNDED TO A COATED SPRING STEEL WIRE HELIX SUPPORTING A FIBER GLASS INSULATING BLANKET R.-6.0. A LOW PERMEABILITY OUTER VAPOR BARRIER OF FIBER GLASS REINFORCED FILM LAMINATE SHALL COMPLETE THE COMPOSITION. J. CONTRACTOR SHALL SUPPLY AND INSTALL INSECT SCREENS ON ALL DUCT OPENINGS WHICH TERMINATE OUTDOORS AND ALL RETURN AIR PLENUM DUCT DROPS. INSECT SCREENS SHALL BE 10 GAUGE, ONE-HALF INCH (1/2") MESH IN REMOVABLE GALVANIZED STEEL FRAMES. K. ALL DUCTWORK SHALL BE DESIGNED IN ACCORDANCE WITH THE PROCEDURES DESCRIBED IN THE LATEST EDITION OF THE AMERICAN SOCIETY OF HEATING REFRIGERATION AND AIR CONDITIONING ENGINEERS GUIDE (ASHRAE), FABRICATED AND INSTALLED IN ACCORDANCE WITH THE METHODS RECOMMENDED IN THE SHEET METAL AND AIR CONDITIONING CONTRACTORS NATIONAL ASSOCIATION (SMACNA) HVAC DUCT CONSTRUCTION STANDARDS - METAL AND FLEXIBLE. L. MECHANICAL FASTENERS AND SEALS, MASTICS, OR GASKETS MUST BE USED WHEN CONNECTING DUCTS TO FANS AND OTHER AIR DISTRIBUTION EQUIPMENT. HANGERS AND SUPPORTS A. HANGER DESIGN SHALL BE AS DESCRIBED IN THE LATEST EDITION OF THE "SMACNA" MANUAL. REINFORCEMENT MEMBERS MAY BE USED TO SUPPORT DUCT SYSTEM PROVIDED DETAILS OUTLINED IN THE "SMACNA" MANUAL ARE ADHERED TO. B. DUCTS SHALL BE SUPPORTED AT ALL TURNS AND TRANSITIONS AND NOT MORE THAN 8'-0" O.C. STRAIGHT DUCTS UP TO 59" MAX. DIMENSIONS SHALL BE SUPPORTED 6'-0" O.C. DUCTS OVER 60" MAX. DIMENSIONS SHALL BE SUPPORTED AT 4'-0" O.C. C. ALL HORIZONTAL DUCTS HAVING A DIMENSION OF 40 INCHES AND LESS SHALL BE SUPPORTED BY MEANS OF BAND IRON HANGERS OF NO. 18 U.S. GAUGE ATTACHED TO DUCT BY MEANS OF RIVETS, SCREWS OR CLAMPS, AND FASTENED TO STRUCTURE ABOVE BY TOGGLE BOLTS OR OTHER MEANS. EACH SECTION OF DUCTWORK SHALL HAVE AT LEAST ONE PAIR OF SUPPORTS. VERTICAL DUCTS SHALL BE SUPPORTED WITH 1-1/4" x 1-1/4" x 1-1/4" ANGLES AT FLOOR PENETRATIONS. D. ALL HORIZONTAL DUCTS HAVING A DIMENSION OF 40 INCHES AND MORE SHALL BE SUPPORTED BY MEANS OF ANGLE IRON TRAPEZE HANGERS. EACH SECTION OF DUCTWORK SHALL HAVE AT LEAST ONE PAIR OF SUPPORTS. E. ALL DUCTS SHALL BE REINFORCED ACCORDING TO THE LATEST EDITION OF "SMACNA" MANUAL. MATERIALS FOR REINFORCEMENT MEMBERS SHALL BE GALVANIZED STEEL. ALL SCREWS AND WASHERS SHALL BE PLATED OR GALVANIZED. FLASHING A. CONTRACTOR SHALL PROVIDE WATER TIGHT 24 GA. SHEET METAL FLASHING AT ALL EXTERIOR WALLS AND ROOF PENETRATIONS. B. ALL CUTTING OF ROOF OPENINGS, SUPPORTS FOR ROOF OPENINGS, PITCH PANS, ROOF CURBS, FLASHING, COUNTER FLASHING, REPAIR TO ROOF, ETC. ASSOCIATED WITH HVAC SUBCONTRACTOR SHALL BE INCLUDED IN THE RESPONSIBILITY OF THE HVAC SUBCONTRACTOR. HE SHALL EMPLOY THE LANDLORD'S ROOFERS FOR THIS WORK TO MAINTAIN THE ROOF WARRANTY. DAMPERS A. SPLITTER DAMPERS SHALL BE FABRICATED OF SHEET STEEL NOT LESS THAN NO. 16 U.S. GAUGE WITH THE LEADING EDGE HEMMED. EACH DAMPER TO BE SIZED ADEQUATELY TO COVER THE SMALLER OF THE TWO OPENINGS IT CONTROLS. DAMPERS SHALL BE CONTROLLED AS FOLLOWS: 1. EXPOSED OR ACCESSIBLE DUCTWORK - LOCKING QUADRANTS EQUAL TO YOUNG REGULATOR NO. 1 WITH DAMPER ROD END BEARINGS ON OPPOSITE END. 2. CONCEALED DUCTWORK - LOCKING QUADRANT EQUAL TO YOUNG REGULATOR NO. 315 (CHROMIUM PLATED WITH DAMPER ROD END BEARINGS ON BOTH ENDS). B. VOLUME DAMPERS SHALL BE OF THE OPPOSED INTERLOCKING TYPE AS MANUFACTURED BY AMERICAN FOUNDRY AND FURNACES CO. (AFFCO) OR EQUAL. BLADES SHALL BE OF NO. 16 GAUGE SHEET METAL AND SHALL NOT EXCEED 48" IN LENGTH OR 12" IN WIDTH. BLADES SHALL BE ON ONE-HALF INCH (1/2") DIAMETER RUSTPROOF AXLE. BEARINGS TO BE OF THE SELF-LUBRICATING FERRULE TYPE. C. FIRE DAMPERS SHALL BE SUPPLIED AND INSTALLED BY HVAC CONTRACTOR AT DUCT PENETRATIONS IN FIRE RATED WALLS, FLOORS, CEILINGS AND ROOF AS REQUIRED. COORDINATE WITH LANDLORD, LOCAL FIRE MARSHALL AND ALL CODES AND GOVERNING AUTHORITIES HAVING JURISDICTION. D. FIELD FABRICATED TURNING VANES SHALL BE ACCEPTABLE IN SQUARE ELBOWS. PROVIDE AND INSTALL BARBER-COLMAN AIRTURNS OR EQUAL. TURNING VANES SHALL BE OF THE SAME GAUGE METAL AS THE DUCT IN WHICH THEY ARE INSTALLED. RADIUS ELBOWS SHALL HAVE A CENTER LINE RADIUS OF ONE AND ONE-HALF (1-1/2) TIMES THE DUCT WIDTH. DUCTWORK - EXCEPTIONS DUCTWORK FOR EXHAUST OR OUTSIDE SUPPLY AIR SHALL BE ALL METAL AND CONSTRUCTED ACCORDING TO RECOMMENDED PRACTICES OF THE LATEST ISSUE OF ASHRAE AND SMACNA STANDARDS. ACCESSORY ITEMS ALL MANUAL DAMPERS, FIRE DAMPERS, TURNING VANES, REGISTER CONNECTIONS, ACCESS DOORS OR OTHER ASSOCIATED ACCESSORIES SHALL BE INSTALLED ACCORDING TO THE LATEST EDITION OF "SMACNA" MANUAL. TESTING AND ADJUSTING CONTRACTOR SHALL EMPLOY AN INDEPENDANT, CERTIFIED TEST AND BALANCE CONTRACTOR TO DEMONSTRATE OPERATION OF SYSTEM TO FULL SATISFACTION OF TENANT, SHALL BALANCE AIR FLOW AND TEMPERATURES IN ACCORDANCE WITH AIR QUANTITIES ON DRAWINGS AND SHALL RECORD VOLUME READINGS IN ACCORDANCE WITH ASHRAE AND PROVIDE SAME TO TENANT AND LANDLORD'S REPRESENTATIVE. OPERATION AND MAINTENANCE DOCUMENTATION MUST BE PROVIDED TO THE OWNER THAT INCLUDES AT LEAST THE FOLLOWING INFORMATION: A. EQUIPMENT CAPACITY (INPUT AND OUTPUT) AND REQUIRED MAINTENANCE ACTIONS. B. EQUIPMENT OPERATION AND MAINTENANCE MANUALS. C. HVAC SYSTEM CONTROL MAINTENANCE AND CALIBRATION INFORMATION, INCLUDING WIRING DIAGRAMS, SCHEMATICS, AND CONTROL SEQUENCE DESCRIPTIONS; DESIRED OR FIELD -DETERMINED SET POINTS MUST BE PERMANENTLY RECORDED ON CONTROL DRAWINGS, AT CONTROL DEVICES, OR, FOR DIGITAL CONTROL SYSTEMS, IN PROGRAMMING COMMENTS. D. COMPLETE NARRATIVE OF HOW EACH SYSTEM IS INTENDED TO OPERATE. E. EWB/EDB AND LWB/LDB FOR THE COOLING/HEATING COIL. ALL PIPING SHALL WITHSTAND AIR PRESSURE TESTiNG PER GOVERNING PLUMBING CODE. GUARANTEE ALL MATERIALS, EQUIPMENT, AND WORKMANSHIP SHALL BE GUARANTEED FOR A PERIOD OF ONE (1) YEAR AFTER DATE OF ACCEPTANCE. THE COMPLETED SYSTEM SHALL BE FULLY OPERATIONAL AND ACCEPTANCE BY TENANT SHALL BE A CONDITION OF THIS CONTRACT. ALL WORK FOUND TO BE DEFECTIVE SHALL BE REPAIRED OR REPLACED BY THIS SUBCONTRACTOR WITHOUT ADDITIONAL COST TO THE TENANT. EQUIPMENT A. EXHAUST FANS. EXISTING TO REMAIN. B. THERMOSTATS ALL HVAC UNITS SHALL BE EQUIPPED HONEYWELL #TB8220U" VISION PRO", 7 -DAY PROGRAMMABLE THERMOSTAT. T -STAT SHALL HAVE 2 HEAT/2 COOL CYCLE, AUTO CHANGE OVER, AND HEAT PUMP COMPATIBLE. THERMOSTAT SHALL BE PROVIDED WITH REMOTE WALL MOUNTED TEMPERATURE SENSOR MODEL # C7189U. DESIGN AND STANDARD CONDITIONS FOR THERMOSTAT OPERATION SHALL BE AS FOLLOWS: COOLING: 757 MAXIMUM OCCUPIED COOLING TEMPERATURE 857 COOLING NIGHT SETBACK. HEATING: 707 MAXIMUM OCCUPIED HEATING TEMPERATURE 60'F HEATING NIGHT SETBACK. FAN: CONTINUOUS IN OCCUPIED AND RECOVERY MODE AND WITH HEATING OR COOLING EQUIPMENT IN UNOCCUPIED MODE. DEADBAND: CAPABLE OF MAINTAINING A 27 DEADBAND. BACKUP: CAPABLE OF MAINTAINING PROGRAMMED SETTING FOR AT LEAST 24 HOURS WITHOUT POWER. T -STAT SHALL BE INSTALLED PER MANUFACTURERS RECOMMENDATIONS AND MOUNTED SO THAT THE HIGHEST OPERABLE CONTROL IS NOT MORE THAN 48" A.F.F. CONTACT THE LOCAL HONEYWELL DISTRIBUTOR FOR ORDERING. C. EXISTING SPLIT SYSTEM TO REMAIN. REFER TO SHEET M1 FOR ADDITIONAL INFORMATION. SPRINKLER SYSTEM A. SPRINKLER SYSTEM SHALL BE DESIGNED AND INSTALLED BY SPRINKLER CONTRACTOR EMPLOYED BY GENERAL CONTRACTOR AND SHALL BE IN COMPLIANCE WITH NFPA 13 AND ALL APPLICABLE CODES, RULES AND REGULATIONS. CONTRACTOR SHALL OBTAIN AND PAY FOR ALL PERMITS, CERTIFICATES OF INSPECTION AND APPROVALS REQUIRED. THE INSTALLATION OF ALL SPRINKLER WORK SHALL CONFORM TO THE APPLICABLE LOCAL CODES AND STATUES AND LOCAL FIRE DEPARTMENT REGULATIONS. B. SHOP DRAWINGS -THE SPRINKLER CONTRACTOR SHALL SUBMIT SHOP DRAWINGS TO THE TENANT'S LANDLORD AND TO THE APPROPRIATE AUTHORITIES AND INSURANCE UNDERWRITER FOR THEIR APPROVAL. A COPY OF THE APPROVAL LETTER FROM THESE AUTHORITIES SHALL BE FORWARDED TO THE TENANT, LANDLORD AND DESIGN ARCHITECT. C. SPRINKLER HEAD TYPES SHALL BE AS FOLLOWS: 1. STOREFRONT: CONCEALED, CAP TO BE BLACK 2. EXISTING CONCEALED HEADS TO REMAIN, REPLACE WHITE CAP WITH NEW BLACK CAP IN SALES AREA. REFER TO KEYED NOTE 3 ON SHEET M1. 3. EXISTING CONCEALED SPRINKLER HEADS IN STOCK AND FITTING ROOM WITH WHITE CAPS TO REMAIN. NOTE FOR GENERAL CONTRACTOR: IT IS THE RESPONSIBILITY OF THE TENANT'S GENERAL CONTRACTOR TO MAKE USE OF APPLICABLE NOTES AND SPECIFICATIONS LISTED ON THIS SHEET AS THEY MAY PERTAIN TO THE SPECIFIC JOB. OUTSIDE AIR SCHEDULE DESCRIPTION AREA AREA AREA OCCUPANT OCCUPANCY OCCUPANT OCCUPANT BREATHING ZONE AIR ZONE ZONE SUPPLY OUTDOOR 0 (SQ. FT.) OUTDOOR OUTDOOR LOAD RATE C x E/1000 OUTDOOR OUTDOOR ZONE DISTRIBUTION OUTDOOR OUTDOOR AIR AIR 9185 - AIR RATE AIR PER IMC (Pz) AIR RATE AIR OUTDOOR EFFECTIVENESS AIR AIR DESIGN FRACTION 0 - PERIMC (RaAz) TABLE Door Loads PER IMC (RpPz) AIR (Ez) (Voz= REQUIRED (Vpz) (Zp=Voz/Vpz) 0 - TABLE 0 403.3 Partitions TABLE 1926 (Vbz = RpPz 1257 ft2 Vbz/Ez) - Ceiling 0 ft2 0 - 403.3 0 (PEOPLE/1000 Overhead Lighting 403.3 5995 + RaAz) 0 0 - Task Lighting ow 0 - (RA) 0 SQ.FT.) Electric Equipment (Rp) 4704 - 0 0 - People 28 SALES/FITT 1348 0.12 161.8 15 21.0 7.5 157.5 319.3 0.8 399.1 444.0 2300 0.17 STOCK 191 0.12 22.9 0 0.0 20%/20% 0.0 22.9 0.8 28.7 32.0 400 0.07 TOTALS 1539 - ` 14235 0 Zone Conditioning - 32237 6873 - 427.7 0 Plenum Wall Load 0% Ev TOTAL REQUIRED OUTDOOR AIR 475 TOTAL OUTDOOR AIR PROVIDED BY HVAC UNITS 480 0.9 CALCULATIONS BASED ON 2012 MC NOTE: TOILET ROOM SQUARE FOOTAGE IS NOT INCLUDED IN THE OUTSIDE AIR AND TOTAL CFM AMOUNTS FORTHIS SCHEDULE is 111111115iI iI111,11- ik 11, CityName............................................................................................. Seattle IAP DESIGN COOLING DESIGN HEATING Washington COOLING DATA AT Jul 1400:::,,HEATING,DATA':AT.DES COOLING OA DB / WB 84.5 °F / 64.8 OF HTG HEATING OA DB / WB 23:0 F / :19.2 OF ZONE LOADS Details Sensible (BT.0/hr) Latent (BTWhr) Details Sensible >s(BTU/hr) Latent (BTU/hr) Window & Skylight Solar Loads 0 ft2 0 - 0 ft2 - - Wall Transmission 0 ft2 0 - 0 ft2 0 - Roof Transmission 1539 ft2 9185 - 1539 ft2 8720 - Window Transmission 0 ft2 0 - 0 ft2 0 - Skylight Transmission 0 ft2 0 - 0 ft2 0 - Door Loads 0 ft2 0 - 0 ft2 0 - Floor Transmission 0 ft2 0 - 0 ft2 0 - Partitions 1257 ft2 1926 - 1257 ft2 3143 - Ceiling 0 ft2 0 - 0 ft2 0 - Overhead Lighting 2022 W 5995 - 0 0 - Task Lighting ow 0 - 0 0 - Electric Equipment 1539 W 4704 - 0 0 - People 28 4847 5728 0 0 0 Infiltration - 0 0 - 0 0 Miscellaneous - 0 0 - 0 0 Safety Factor 20%/20% 5331 1146 20% 2372 0 Total Zone Loads _ 319$9 6873 - ` 14235 0 Zone Conditioning - 32237 6873 - 13506 0 Plenum Wall Load 0% 0 - 0 0 - Plenum Roof Load 0% 0 - 0 0 - Plenum Lighting Load 0% 0 - 0 0 - Return Fan Load 2700 CFM 0 - 2700 CFM 0 - Ventilation Load 480 CFM 3757 -6854 480 CFM 23746 0 Supply Fan Load 2700 CFM 3002 - 2700 CFM -3002 - Space Fan Coil Fans - 0 - - 0 - Duct Heat Gain / Loss 0% 0 - 0% 0 - Total System Loads 38996 19 3.4249 0 Central Cooling Coil - 38996 0 - 0 0 Central Heating Coil - 0 - - 34249 - »Total Conditioning - 38996 0 34249 0. Key: Positive values are clg loads Negative values are htg loads Positive values are htg loads Negative values are clg loads CityName............................................................................................. Seattle IAP Location.............................................................................................. Washington Latitude............................................................................................................ 47.5 Deg. Longitude....................................................................................................... 122.3 Deg. Elevation........................................................................................................ 449.0 ft Summer Design Dry-Bulb............................................................................... 85.0 OF Summer Coincident Wet-Bulb........................................................................... 65.0 OF SummerDaily Range........................................................................................ 18.3 OF Winter Design Dry -Bulb ................. :.................................................................. 23.0 Winter Design Wet-Bulb.................................................................................... 19.2 of F Atmospheric Clearness Number........................................................................ 1.05 Average Ground Reflectance............................................................................ 0.20 Soil Conductivity............................................................................................. 0.800 BTU/(hr-ft- Local Time Zone (GMT +/- N hours).................................................................... 8.0 hours Consider Daylight Savings Time.......................................................................... No Simulation Weather Data................................................................................... N/A Current Data is............................................................... 2001 ASHRAE Handbook Design Cooling Months......................................................... January to December PMVIEVVED FOR ODE CO PL ANCE APPROVED Y MAY 2 4 2016 RECEIVED CITY OF TUKWIL INIAY 0.9 2015 PERMIT CENTER 0 2 a_ �n