Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Permit M16-0074 - GLASSHAPE - ROOFTOP HVAC UNIT REPLACEMENTS
This record contains information which is exempt from public disclosure pursuant to the Washington State Public Records Act, Chapter 42.56 RCW as identified on the Digital Records Exemption Log shown below. M16-0074 GLASSHAPE 3425S116 TH ST #101 RECORDSDIGITAL D-) EXEMPTION LOG THE ABOVE MENTIONED PERMIT FILE INCLUDES THE FOLLOWING REDACTED INFORMATION Page # Coda Exemption, � � � I3ri6f Explanatory 6escrlofion, Sfatutte/Ruilo The Privacy Act of 1974 evinces Congress' intent that social security numbers are a private concern. As such, individuals' social security Personal Information — numbers are redacted to protect those Social Security Numbers individuals' privacy pursuant to 5 U.S.C. sec. 5 U.S.C. sec. DR1 Generally — 5 U.S.C. sec. 552(a), and are also exempt from disclosure 552(a); RCW 552(a); RCW under section 42.56.070(1) of the Washington 42.56.070(1) 42.56.070(1) State Public Records Act, which exempts under the PRA records or information exempt or prohibited from disclosure under any other statute. Redactions contain Credit card numbers, debit card numbers, electronic check numbers, credit Personal Information — expiration dates, or bank or other financial RCW 43 DR2 Financial Information — account numbers, which are exempt from 42.56.230(5) RCW 42.56.230(4 5) disclosure pursuant to RCW 42.56.230(5), except when disclosure is expressly required by or governed by other law. Personal Information — Redactions contain information used to prove RCW DR3 Driver's License. — RCW identity, age, residential address, social security 42.56.230 (7a 42.56.230 number or other personal information required to & c) (7a & c) apply for a driver's license or identicard. Redacted content contains a communication between client and attorney for the purpose of obtaining or providing legal advice exempt from RCW Attorney -Client Privilege — disclosure pursuant to RCW 5.60.060(2)(a), 5.60.060(2)(a); DR4 RCW 5.60.060(2)(a); RCW which protects attorney-client privileged RCW 42.56.070(1) communications, and RCW 42.56.070(1), which 42.56.070(1) protects, under the PRA, information exempt or prohibited from disclosure under another statute. GLASSHAPE 3425 S 116 ST SUITE 101 EXPIRED 06/27/17 M 1 6-0074 City of Tukwila Department of Community Development • 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Inspection Request Line: 206-438-9350 Web site: http://www.TukwilaWA.eov MECHANICAL PERMIT Parcel No: 1023049043 Permit Number: M16-0074 Address: 3425 S 116TH ST 101 Issue Date: 5/27/2016 WA Cities Electrical Code: 2014 Permit Expires On: 11/23/2016 Project Name: GLASSHAPE 2014 Owner: 2012 WA State Energy Code: Name: EPROPERTY TAX INC DEPT 207 2012 Address: PO BOX 4900, SCOTTSDALE, WA, Permit Center Authorized Signature: 85261 Date:—6 �� Contact Person: Name: DAWNA PETET Phone: (253) 939-9495 Address: 899 W MAIN ST, AUBURN, WA, 98001 Contractor: Name: IECS INC Phone: (206) 939-9495 Address: PO BOX 19252, SEATTLE, WA, 98109- 1252 License No: IECS***044QL Expiration Date: 11/20/2016 Lender: Name: Address: DESCRIPTION OF WORK: REPLACE (2) EXISTING CARRIER 4 TON ROOFTOP HVAC UNITS WITH (2) NEW CARRIER 4 TON ROOFTOP HVAC UNITS Valuation of Work: $18,620.00 Fees Collected: $441.88 Type of Work: REPLACEMENT Electrical Service Provided by: SEATTLE CITY LIGHT Fuel type: GAS Water District: TUKWILA Sewer District: VALLEY VIEW Current Codes adopted by the City of Tukwila: International Building Code Edition: 2012 National Electrical Code: 2014 International Residential Code Edition: 2012 WA Cities Electrical Code: 2014 International Mechanical Code Edition: 2012 WAC 296-466: 2014 Uniform Plumbing Code Edition: 2012 WA State Energy Code: 2012 International Fuel Gas Code: 2012 Permit Center Authorized Signature: Date:—6 �� I hearby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this development permit and agree to theMditions attached to this permit. �' Date: � -� o6 Print Nam This permit shall become null and void if the work is not commenced within 180 days for the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. PERMIT CONDITIONS: 1: Work shall be installed in accordance with the approved construction documents, and any changes made during construction that are not in accordance with the approved construction documents shall be resubmitted for approval. 2: All permits, inspection record card and approved construction documents shall be kept at the site of work and shall be open to inspection by the Building Inspector until final inspection approval is granted. 3: Readily accessible access to roof mounted equipment is required. 4: All construction shall be done in conformance with the Washington State Building Code and the Washington State Energy Code. 5: Remove all demolition rubble and loose miscellaneous material from lot or parcel of ground, properly cap the sanitary sewer connections, and properly fill or otherwise protect all basements, cellars, septic tanks, wells, and other excavations. Final inspection approval will be determined by the building inspector based on satisfactory completion of this requirement. 6: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206-431-3670). 7: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center. 8: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. 9: `MECHANICAL PERMIT CONDITIONS' 10: All mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center (206/431-3670). 11: Manufacturers installation instructions shall be available on the job site at the time of inspection. PERMIT INSPECTIONS REQUIRED Permit Inspection Line: (206) 438-9350 0703 MECH EQUIP EFF 1800 MECHANICAL FINAL 0705 REFRIGERATION EQUIP 0701 ROUGH -IN MECHANICAL 0702 SMOKE DETECTOR TEST CITY OF TUKWILA Community Development Department • Permit Center • 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://www.TukwilaWA.gov SITE LOCATION Site Address Tenant Nam Mechanical Permit No. b _ 0M I Project No. Date Application Accepted: —IV--' (0 Date Application Expires: .� t (For office use only) MECHANICAL PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. "please print" King Co Assessor's Tax No.: In )LLQ ')U "-�,_ Number: A �J i Floor: New Tenant: ❑ .....Yes �..No PROPERTY OWNER Name: b I O Address . City: State: Zip projectCONTACT PERSON — person receiving all communication Address:0-0 1.J.� A �� `i 107 MECHANICAL CONTRACTOR INFORMATION Company Name: Address: Q 11), City: State: M4Zip: / Phone: Contr Reg Exp Date: 'V2- Tukwila Business License No.: Valuation of project (contractor's bid price): $ , �� o , Describe the scope of work in detail:R e x(S, l � �� r Tgn 0f 4voc, turLE+S (2) N w C�a Ton Rco�� Use: Residential: New .......... Replacement ........ ❑ Commercial: New .......... Replacement.......:' Fuel Tvne: Electric ..... ❑ Gas ....... Other: H:Wpplications\Fomr,Applications On Line\2016 Applications\Mwhanical Permit Application Revised 1-4-16.docx Revised: January 2016 Paee 1 of Indicate type of mechanical work being installed and the quantity below: Unit Type Qty Furnace <100k btu Residential, Nighttime Furnace >100k btu Industrial Floor furnace 55 dB(A) Suspended/wall/floor mounted heater 57 dB(A) Appliance vent Commercial Repair or addition to heat/refrig/cooling system 47 dB(A) Air handling unit <10,000 cfm 65 dB(A) Unit Type Qty Air handling unit >I 0 000 cfm Residential, Nighttime Evaporator cooler Industrial Ventilation fan connected to single duct 55 dB(A) Ventilation system 57 dB(A) Hood and duct Commercial Incinerator — domestic 47 dB(A) Incinerator — comm/industrial 65 dB(A) Unit Type Qty Fire damper Diffuser Thermostat Wood/gas stove EmerRencv venerator Other mechanical equipment R bof,o HVA-cun �5 Boiler/Compressor Qty 0-3 hp/100,000 btu 3-15 bp/500,000 btu 15-30 hp/1,000,000 btu 30-50 hp/1,750,000 btu 50+ hp/1,750,000 btu Noise Mechanical units need to be in compliance with the Tukwila Noise Code. Maximum permissible sound levels are based on from where the sound is created and where the sound is heard. Additionally, if sound can be heard from within a house at night in a residential zone it may not be allowed. For more details, see TMC 8.22 District of Sound Producing Source District of Receiving Property Residential, Daytime* Residential, Nighttime Commercial Industrial Residential 55 dB(A) 45 dB(A) 57 dB(A) 60 dB(A) Commercial 57 dB(A) 47 dB(A) 60 dB(A) 65 dB(A) Industrial 60 dB(A) 50 dB(A) 65 dB(A) 70 dB(A) *Daytime means 7AM-IOPM, Monday through Friday and 8AM-1 OPM, Saturday, Sunday and State -recognized holidays. A few sounds are exempt from the noise code, including: Warning devices; Construction and property maintenance during the daytime hours (lam -1 Opm); Testing of backup generators during the day. PERMIT APPLICATION NOTES - Value of construction — in all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the permit center to comply with current fee schedules. Expiration of plan review— applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The building official may grant one extension of time for additional periods not to exceed 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. Date: �T—,2 V6 City State Zip H:\Applicatiorts\Forms-Applicatiors On Line\2016 ApplicatiorsWechanical Permit Application Revised 1-4-16.docx Revised: Januarv2016 Pam 2 of l DESCRIPTIONS ACCOUNT QUANTITY PAID PermitTRAK $779.24 M16-0074 Address: 3425 S 116TH ST 101 Apn: 1023049043 $441.88 MECHANICAL $424.88 PERMIT ISSUANCE BASE FEE R000.322.100.00.00 0.00 $32.50 PERMIT FEE R000.322.100.00.00 0.00 $307.40 PLAN CHECK FEE R000.322.102.00.00 0.00 $84.98 TECHNOLOGY FEE $17.00 TECHNOLOGY FEE R000.322.900.04.00 0.00 $17.00 M16-0075 Address: 12870 INTERURBAN AVE S Apn: 2716000010 $337.36 MECHANICAL $324.38 PERMIT ISSUANCE BASE FEE R000.322.100.00.00 0.00 $32.50 PERMIT FEE R000.322.100.00.00 0.00 $227.00 PLAN CHECK FEE R000.322.102.00.00 0.00 $64.88 TECHNOLOGY FEE $12.98 TECHNOLOGY FEE TOTAL FEES • +R8426 R000.322.900.04.00 0.00 $12.98 $779.24 Date Paid: Tuesday, May 10, 2016 Paid By: SEATTLE MECHANICAL INC Pay Method: CHECK 9687 Printed: Tuesday, May 10, 2016 11:11 AM 1 of 1 rW SYSTEMS INSPECTION RECORD Retain a copy with permit�� INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Project: Type o pin�s-pgction: Addr s 1 �t d Date Called: Special Instructions: /A �.✓" 1'" Date tan d: ) ( a.m. 1 b p.m. Requester: Phone No: 11 Approved per applicable codes. a Corrections required prior to approval. I4-1 j l inspector: r/ / uate6 y 2 -(6 I REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. r REVISIONS r No changes shell be made to the scope of vrork tnrithout prior approval of I i uk-wila Building Division_ will require anew plan submittal grid may irt;;lude additional plan review fees. FILE COPY Permit No. J4 Pan approval is subject to errors and omissions. Ar -11 -oval of construetion documents does not authorize t 'J vioioticn ;+ any adopted code or ordinance. Receipt of approved ^� Copy and con its n� is cknov�ledged: Lona PX - Date: - (� City of Tukwila BUILDING DIVISION Ml 6- 00711 ,SFP P, i F PERMIT RHOU ED FOR: ❑ Mechanicei fry' lectricei C&iumbing Cas Piplr1 Clay of Tukwila St...l"_DIN'' DIVISI, REVIEWED FOR ODE COMPLIANCE APPR41iED I . MAY 2 4 2016 o -f VIS City of Tukwila BUILDING DIVISION RECEIVED CITY OF TUKWILA MAY 10 2016 PERMIT CENTER pr i t � lio cul St 14 6 f0o rrvq &IOW CA Rlrulc r SYSIAG PER ► S 7"' fTu �t . hit"..,r- N A VVED FOR 24 2096 Ma Tula I'M 4 # 0 DIVISION Ak • A` -Y ■ ■ YlLaViY® Ifs- ® - Inn n Y 102016 OTCENTER rr� dy f �• ��� U 1. �E� ��IL �i a � `' C .. sr � � " s • r S � _ — i. .. . � - �z.� t ..1� ..11a :'� . �. 4 ;.r �`• �� i . '!.�.Y r - qi/'i . Goo(Sle- earth eel' 1300 meters 100 2012 Washington State Energy Code Project Info IL Forms for Commercial, Group R1, and > 3 story R2 & R3 Revised June 2013 ect Address Al ' p c' / Date S, 116.tYU1 —4t For Building Dept. Use (Applicant Name: ADDllcant Address n^— Project ^.. Project Description Tl Cat �'-S-i l Calk 4 Tim Briefly describe mechanical -rI + x1 l % ii�tw system type and features. �'i! A- Includes Plans � tU 4cP C Include documentation requiring compliance with commissioning provisions per Section C408. Compliance Option imple System Domplex System Oystems Analysis Equipment Schedules The following information is required to be incorporated with the mechanical equipment schedules on the plans. For projects without plans, fill in the required information below. 41DType Brand Name' Model No.' eating Equipment Schedule quip. Equip ID Type Brand Name' Model No.' Fan E ui ment Schedule Equip. Equip ID Type Brand Name' Model No.' Service Water Heating Equipment Schedule Btu/h I or Econo? I or EER I (PLV' I Option or I Recovery Exceptions Y/N 0 Btu/h I or Econo?I Input Btuh I Output Btuh I Efficiency' I Recovery Y/N CFM I SP' I HP/BHP Equip. ID Equip Type Brand Name' Model No.' Input Capacity Sub - Category EF' Location of Service A!l MUMMY— IL LU 4L�� " dvdnaoie. , As testeo according to Table C403.2.3(1)A thru C403.2.3(8). 3 If required. 4 COP, HSPF, Combus riMllb applicable. S Flow control types: variable air volume (VAV), constant volume (CV), or variable speed (VS). 6 Econom¢ Svstems C403.3.1 or Complex Svstems C403.4.1. 7 Efficiencv Factor per Table C404.2. �ple 12012 Washington State Energy Code Compliance Forms for Commercial, Group R t, and > 3 story R2 & R3 r a Revised June The following information is necessary to check a mechanics permit application for commercial provision compliance with the 2012 WSEC. NOTE: Define Printarea In Excel priorto printing MECH-CHK pages. Applicability Code Section (yes,no,ne) _Code Information Required Location on Building Department Plans Notes GENERAL PROVISIONS Ipment Sizing & Performance C403.2.1 Load calculations Load calculations performed per ASHRAE Std 183 or equivalent per Chapter 3 C403.2.2 Equipment and system sizing Output capacity of heating and cooling equipment and systems do not exceed calculated loads, note exceptions taken C403.2.5 Minimum ventilation Ventilation (natural or mechanical) provided per IMC; indicate mechanical ventilation is capable of being reduced to minimum requirement per IMC C403.2.3 & C403.2.3.2 & Equipment minimum efficiencl Provide equipment schedules or complete MECH-SUM tables with type, capacity, efficiency, test C403.2.12.1 standard (or other efficiency source) for all mechanical equipment C403.2.13 Electric motor efficiency Provide equipment schedule with hp, rpm, efficiency for all motors; note except. C403.2.10 Fan power limitation Fan system motor hp or bhp does not exceed limits per Table C403.2.10.1(1) C403.2 & C403.10.3 & C403.2.13 Fractional hp fan motors Indicate fan motors 1/12 to 1 h are ECM p type or meet minimum efficiency req. C403.2.3 Maximum air cooled chiller Indicate air-cooled chiller capacity does capacity not exceed air-cooled chiller limit C403.2.1 Non-standard water-cooled Full -load and NPLV values for water-cooled centrifugal chiller adjusted for non - chillers standard operational conditions C403.2.12.1.2 Centrifugal fan cooling towers Large capacity cooling towers with centrifugal fan(s) meet efficiency requirements for axial fan open circuit cooling towers C403.2.3 Forced air furnace and unit heaters Indicate intermittent ignition or IID, flue/draft damper & jacket loss C403.2.3.3 Packaged electric heatin /coolin ui ment List equipment required to be heat pumps on schedule C403.2.3.4 Humidification Indicate method of humidification (note requirements for systems with economizer System Controls & Criteria C403.2.4.1 Thermostatic controls Indicate locations of thennostafic control zones on plans, including perimeter systems C403.2.4.1.1 Heat pump supplementary heat Indicate staged heating (compression/supplemental) & outdoor lock -out temp C403.2.4.2 Setpoint overlap (deadband) Indicate 5°F deadband minimum for systems controlling both heating & cooling 0403.2.4.3 Automatic setback and shutdown Indicate zone t -stat controls with required automatic setback & manual override C403.2.4.3.3 Automatic (optimum) start Indicate system controls that adjust equip start time to match load conditions C402.4.5.2 & C403.2.4.4 Damper; Indicate location of OSA, exhaust, relief and return air dampers; include AMCA rated leakage and control motorized or gravity; note exceptions taken C403.2.11 Heating outside a building Indicate radiant heat system and occupancy controls C403.2.4.5 Snow melt systems Indicate shut-off controls based on outdoor conditions C403.2.4.6 - Combustion heating ui ment eqC403.2.4.7 Indicate modulating or staged control Group R1 hotel/motel systems Indicate method for guest room automatic setback & set-up of 5"F minimum C403.2.4.8 / g Group R2/R3Edwellingnit Indicate52 programmable thermostats in primary spaces with minimum of two s stems setback eriods; note excetions taken C403.2.5.1 Demand contlation Indicate high -occupancy spaces and systems requiring DCV 0403.2.5.2 Occupancy sensors Indicate spaces requiring occupancy -based system control and method; or alternate means provided to automaticall reduce OSA when partially occupied Enclosed loading C403.2.5.3 dock/parking garage Indicate enclosed loading dock and enclosed parking garage ventilation system ventilation activation and control method C403.2.5.4.1 Kitchen exhaust hoods Indicate kitchen hoods requiring make-up air; indicate make-up air source and conditioning method C403.2.5.4.2 Laboratory exhaust systems Indicate lab exhaust systems requiring heat recovery, method & efficiency; or alternative method taken (VAV, semi -conditioned makeup, or CERM calculation) C403.2.6.1 Energy systems recovery - ventilation Indicate ventilation systems requiring ER, method & efficiency; note exceptions Energy recoveE-condensate stems Indicate on-site steam heatin s stems re uirin encs 9 Y q g rgy recovery Energy Ms recoveenser stems Indicate remote refrig, condensers requiring ER and use of captured energy 2012 Washington State Energy Code Compliance Forms for Commercial, Group R1, and > 3 story R2 8 R3 Revised June 2013 Project Address ~ ,A— Date The following information is necessary to check a mechanical p rmit application for commercial provision compliance with the 2012 WSEC. NOTE: Define print area in Excel prior to printing MECH-CHK pages. Applicability o,na) (yes,no,na) Code Section Code Provision Information Required Location on Building Department 9 P Plans Notes (ENEPAUP I MSION$'00 f1NU® HVAC System Controls & Criteria, Continued C403.2.12 Variable Flow control - Indicate fan & pump motors requiring VF control & method (VSD or equiv fans/ um s controls C403.2.12.1 Variable flow control - cooling towers Indicate cooling tower fans requiring variable flow control and method C403.2.12.2 Large volume fan systems Indicate fan systems requiring airflow reduction based on heating and cooling demand; or exception taken C403.2.12.2 Single zone AC systems Indicate method of cooling demand -based fan control for sys. > 110,000 btuh C403.2.4.10 DDC system capabilities Identify all DDC system input/output control points and indicate capability for Itrencling and demand respon olnt adiustment Ducting Systems C403.2.7.1 & Duct construction Indicate all ductwork constructed and sealed per IMC, C402 leakage C403.2.7.3 requirements and IBC vapor retarder requirements C403.2.7.3.1 -21 Duct pressure classifications Identify location of low, medium and high pressure ductwork on plans C403.2.7.3.3 High pressure duct leakage Indicate high pressure duct leakage testing requirements on plans; provide test test results to jurisdiction when completed C403.2.7.1 / 2 Duct insulation Indicate R -value of insulation on ductwork Piping Systems i A)/ C403.2.8 Piping insulation 1PIping R-value of insulation on piping EIndicate C403.2.8.1 insulation exposed to method of protection from damage/degredation SIM PLESYSTEM S Qualifying Systems C403.3 Qualifying single zone Verify unitary or packaged equipment does not exceed capaciA limits, does not If-ty systems have active humidifcation or simultaneous heating/cooling C403.3 Qualifying 2 -pipe heating systems Verify 2 -pipe heating -only system does not exceed capacity limits C403.3.2 Hydronic system controls Refer to Complex Systems Section C403.4.3 Simple System Economizers C403.3.1 Air economizer required Indicate cooling systems requiring economizer controls; note in equip sched. C403.3.1.1.1 Air economizer capacity Indicate modulating OSA control capability up to 100% OSA, or exception C403.3.1.1.3 Air controls economizer high limit Indicate high limit shutoff control method per Table C403.3.1.1.3(2) C403.1.1.2 Integrated air economizer Indicate capability for partial air economizer operation for systems with capacity o eration > 65,000 btuh C403.3.1 Air economizer exceptions Indicate eligible exception(s) taken and provisions to comply with exception(s) 40M RIX&STEM S Complex System Economizers C403.4.1 Air economizer required Indicate cooling systems requiring economizer controls; note in equip sched. C403.4.1.4 Economizer heating system Verify control method of HVAC systems with economizers does not increase impact building heating energy usage during normal operation C403.4.1.3 Integrated economizer Indicate capability for partial economizer operation for air or water econo operation systems Moved Water economizer capacity Indicate water econo capable of 100% cooling capacity at 50°F db/45°F wb OSA C403.4.1.2 Water pressure economizer maximum drop Indicate precooling coils and heat exchangers do not exceed pressure drop limit C403.3.1 Air economizer exceptions Indicate eligible exception(s) taken and provisions to comply with exception(s) 2012 Washington State Energy Code Compliance Forms for Commercial, Group R1, and > 3 story R2 & R3 Revised June 2013 Project Address Date The following infonnatlon is necessary to check a mechanical Pettmit application for commercial provision compilance with the 2012 WSEC. NOTE: Define print area in Excel prior to rintin MECH-CHK pages. Applicability Code Section (yes,no,na Code Provision Information Required Location on Building Department 9 Pa Plans Notes ��(�'WS(�N71NU® Specific System Requirements 0400403.2.12 3.4.2 & Variable flow control - fans Indicate fans requiring variable flow control and method C403.4.2.1 VAV fan static pressure Indicate sensor locations on plans; include at least one sensor per major duct sensors branch C403.4.2.2 VAV fan static pressure Indicate fan system static pressure setpoint based on zone requiring most setpoint pressure C403.4.5 VAV systems serving multi- Indicate supply air systems serving multiple zones that are required to be VAV, zones method of primary air control, and zones served; note exceptions taken C403.4.5.4 VAV system supply air reset Indicate controls that automatically reset supply air temp in response to loads C403.4 Large capacity cooling Indicate method of multi -stage or variable control for building cooling system systems capacity > 300 tons C403.4.7 Hot gas bypass limitation Indicate cooling equipment unloading or capacity modulation method C403.4.3 Large capacity boiler systems Indicate multi -stage or modulating burner for single boilers > 500,000 btuh C403.4.3 Boiler sequencing Indicate automatic controls that sequence operation of multiple boilers C403.4.3.5 Chiller / boiler plant pump Indicate capability to automatically reduce overall plant flow and shutoff flow Isolation through chillers & boilers when not In use 0403.4.2 & 0403.4.3.6 Variable flow control - pumps Indicate pumps requiring variable flow control & method Variable flow control -cooling & & 040 C403.4.4.4.4 towers Indicate cooling tower fans requiring variable flow control and method 0403.4.3.4 I Hydronic system part load Indicate heating & chilled water systems have the capability to automatically controls reset supply water temp AND reduce flow by 2 50% fors stems > 300,000 btuh C403.4.3.2 Two-plpe changeover Indicate deadband, heating/cooling mode scheduling and changeover systems temperature range C403.4.3.3.1 Water loop heat pump - Indicate capability of central equipment to provide min. 20°F water supply temp deadband deadband between heat rejection and heat addition modes C403.4.3.3 Water loop heat pump - heat Provide heat exchanger that separates cooling tower and heat pump loop in rejection Climate Zone 5 0403.4.3.3.3 Water loop heat pump - Indicate 2 -way isolation valve on each heat pump and variable flow control for isolation systems with total Dump power > 10 h ip 0403.4.6 Condenser water heat recovery Indicate system provided to pre -heat service water and efficiency C403.5 Cooler / freezer - anti -sweat heaters Indicate w/sf & control method for walk-in cooler/freezer door anti -sweat heaters 0403.5 / 6 Cooler / freezer - evaporator a tans indicate moor p t type for eva orator and condenser fans < 1 hp n SER/I9QWATW<H6411NG Service Water Systems 0404.2 Water -heating equip min. Provide equipment schedule or complete MECH-SUM table with type, capacity, efficiency efficiency, test standard or other effcienc I source C404.3 Temperature controls Indicate temperature controls have required selpoint capability 0404.4 Heat traps Indicate piping connected to equipment have heat traps on supply & discharge C404.5 Insulation under water heater Indicate R-10 insulation under tank 0404.6 Service insulation water piping Indicate R -value of insulation on piping; note exceptions taken C404.7 / g Circulation trace systems and heat shutoff Indicate shutoff capability based on occupancy and periods of limited demand C404.9 Group meters R-2 service hot water Indicate method of usage metering for dwell. units served by central HW system Pools & In -Ground Permanently Installed Spas If C404.10.1 Pool heating equip min. Provide equipment schedule or complete MECHSUM table with type, capacity, (� f efficiency efficiency, test standard (or other eft. source); heat pump heaters z 4 COP C404.10.1 / 2 Pool heater on / off controls Indicate automatic on/off control based on scheduling & accessible on/off switch on heater that operates independent of thermostat setting; or exception taken C404.10.3 Pool covers Indicate vapor retardant cover and insulation rating as required C404.10.3 Pool assembly insulation Indicate rating of insulation on sides and bottom of pools heated to > 90°F 0404.10.4 Heat recovery Indicate method, exhaust air temperature reduction and recovered energy use parrier Technologies SUBMITTAL Project Glasshape Date Wednesday, March 16, 2016 Contractor Seattle Mechanical REVIEWED FOR CODE CQMFLWNCE APPROVED MAY 2 4 2016 City of Tadd BUILDING om$I0N M I (oft- Doti CITY OF TUKWILA MAY 101016 PERMIT CENTER A Unit Project: Glasshape 04/04/2016 Prepared By: 04:54PM M Unit Tag Cover Sheet Unit Report Certified Drawing Performance Report Unit Feature Sheet Spec Sheet Packaged Rooftop Builder 1.40 Page 2 of 11 Unit Report For 4t Unit Project: Glasshape 04/04/2016 Prepared By: 04:54PM Unit Parameters Description Quantity Rooftop Unit 2 Dimensions (ft. in.) & Weight (lb.) *** Unit Model:. -------- ...... ................... . 48KCDA05A2A6-0A0A0 Unit Length:.-.--.- ---- .------- ..---- ..--- 2.375'• Unit Size: ............................. -------------------------- ---.05 (4 Tons) ------- -------------- _---_6' Unit Width:-- ------------- ------ 3' 10.75" Volts -Phase -Hertz: -----------------...................... .-------------- 460-3-60 -......................... Unit Height: ---------_----........ -............ 2' 9.375.. Heating Type----------------------- ----- ------------_------------- ------------------- Gas .................... .., Total Operating Weight:....................... Ib Duct Cfg:--------- ------ ..... Vertical Supply / Vertical Return --- ---.....604 Low Heat '•' Weights and Dimensions are approximate. Weight does Single Stage Compressor Models not include unit packaging. Approximate dimensions are provided primarily for shipping purposes. For exact dimensions and weights, refer to appropriate product data catalog. Lines and Filters Return Air Filter Type ............... Throwaway Return Air Filter Quantity Return Air Filter Size: --------------------------------- x 25 x 2 Unit Configuration Medium Static Option Belt Drive AI/Cu - AI/Cu Base Electromechanical Controls Standard Packaging Warranty Information 1 -Year parts(std.) 5 -Year compressor parts(std.) 10 -Year heat exchanger - Aluminized(std.) No optional warranties were selected. NOTE: Please see Warranty Catalog 500-089 for explanation of policies and ordering methods. Ordering Information Part Number 48KCDA05A2A6-OAOA6 Description Quantity Rooftop Unit 2 Accessories CRECOMZR067A00 Ultra LOW LEAK - Vertical EconoMi$er X with solid-state W7220 2 controller Packaged Rooftop Builder 1.40 Page 3 of 11 Certified Drawing for 4t Unit Project: Glasshad B pe 04/04/2016 Pre ace 04:54 )M 11 I utast BACK °ROLE VI TM 11-1/ I I r usu u-tn 1/-w Ir -v1 oat aoI Ina CONVERSER 0111. OPTIONAL— FACT T PTIONALFACTONT RAALLEO COMMERCE MLLT San nm aan - aten LEFT Packaged Rooftop Builder 1.40 Ila/e 184 3e -I11 • fCONONRR IIOOO 1� � lorrtaw u uoa MRL IEESS SLOWER ACCESS CC 1. I,AfA7)DInAFJIY �Ill11RCR[TFpi 1MER°IONS J OITIONAL YAIi J N L.1 PNAIEI R a SHARE)] !. CENTER OF GRAY17YIIIfC rkc 11111 I6fellEO SI 11 !le 11111 II TIL. [J111 II 1 71 1/ 1] 1 1. M10, DIRECTION! Qi AIN FILM11111 ZINC L.1 J7 Sle 10 In IJi/l 11 7I1 1117] dU LT AIA All /deco 11 mi a 1n a ae nose nm ula 11 I utast BACK °ROLE VI TM 11-1/ I I r usu u-tn 1/-w Ir -v1 oat aoI Ina CONVERSER 0111. OPTIONAL— FACT T PTIONALFACTONT RAALLEO COMMERCE MLLT San nm aan - aten LEFT Packaged Rooftop Builder 1.40 Ila/e 184 3e -I11 • fCONONRR IIOOO 1� � lorrtaw u uoa FRONT CORRECTION SIZE[ A 1 711. 1751 DIA FIELD PONER SIPFLY NOL[ 0 [' Ism DIA POWER Sarni RNDCRWf C 1 J/1• I5I1 DIA RAISE ACCESS PLOD D las' ler] DER FIELD CONTROL. 91116 ROLE E 3//'-11 6T CONDE6ATE MAIN E I1e'-11 RPT SAS CONNECTION D z IR , [SII DIA POWER SUIPLI RaN-0V1 TM-THE-IASE CHJAf TRICE HOLE' AEODIIEI PON USE C6TMITMIAOI, IDJAOI TWAOED RIR[ A[O'D RDI[ CONOI]I '1't VSE Jlrfe IW.I R Ilr' ACC. ll1' [le.ei ' yr z/r yr IR.a T . mr mol 071 POWER 1 RAH• tze.a Z•• nml ve• rrI ass 'FIR• ,.IO.e FOR 'TA6-TRE-IAS[IAA' FACTORT OI11ON rITTI6S FON DRIP C./, A' ARE PAMIDto (ELECT EI7HE' J/1• rONFI, RIEIDI6 q p Ile' FOR 916 !IR 10011 PAOu6c nraDR 1 11/• 7rI6.AT THIU cub MRL IEESS SLOWER ACCESS CC J OITIONAL W11 tONOC11SIIR. DAAEA rkc 11111 I6fellEO ,I i-pAAME OISCONAECT Es-ve : 00 r��fR-318 dU LT AIA All AAIRRSIDE 4m Iau 1 / nm nsa — N -ill 3e21 71-1H RA TAX RELIEF 1' rLON FRONT CORRECTION SIZE[ A 1 711. 1751 DIA FIELD PONER SIPFLY NOL[ 0 [' Ism DIA POWER Sarni RNDCRWf C 1 J/1• I5I1 DIA RAISE ACCESS PLOD D las' ler] DER FIELD CONTROL. 91116 ROLE E 3//'-11 6T CONDE6ATE MAIN E I1e'-11 RPT SAS CONNECTION D z IR , [SII DIA POWER SUIPLI RaN-0V1 TM-THE-IASE CHJAf TRICE HOLE' AEODIIEI PON USE C6TMITMIAOI, IDJAOI TWAOED RIR[ A[O'D RDI[ CONOI]I '1't VSE Jlrfe IW.I R Ilr' ACC. ll1' [le.ei ' yr z/r yr IR.a T . mr mol 071 POWER 1 RAH• tze.a Z•• nml ve• rrI ass 'FIR• ,.IO.e FOR 'TA6-TRE-IAS[IAA' FACTORT OI11ON rITTI6S FON DRIP C./, A' ARE PAMIDto (ELECT EI7HE' J/1• rONFI, RIEIDI6 q p Ile' FOR 916 !IR 10011 PAOu6c nraDR 1 11/• 7rI6.AT THIU cub MRL IEESS SLOWER ACCESS CC J OITIONAL W11 tONOC11SIIR. DAAEA rkc 11111 I6fellEO ,I i-pAAME OISCONAECT Es-ve : 00 r��fR-318 dU LT AIA All FRONT CORRECTION SIZE[ A 1 711. 1751 DIA FIELD PONER SIPFLY NOL[ 0 [' Ism DIA POWER Sarni RNDCRWf C 1 J/1• I5I1 DIA RAISE ACCESS PLOD D las' ler] DER FIELD CONTROL. 91116 ROLE E 3//'-11 6T CONDE6ATE MAIN E I1e'-11 RPT SAS CONNECTION D z IR , [SII DIA POWER SUIPLI RaN-0V1 TM-THE-IASE CHJAf TRICE HOLE' AEODIIEI PON USE C6TMITMIAOI, IDJAOI TWAOED RIR[ A[O'D RDI[ CONOI]I '1't VSE Jlrfe IW.I R Ilr' ACC. ll1' [le.ei ' yr z/r yr IR.a T . mr mol 071 POWER 1 RAH• tze.a Z•• nml ve• rrI ass 'FIR• ,.IO.e FOR 'TA6-TRE-IAS[IAA' FACTORT OI11ON rITTI6S FON DRIP C./, A' ARE PAMIDto (ELECT EI7HE' J/1• rONFI, RIEIDI6 q p Ile' FOR 916 !IR 10011 PAOu6c nraDR 1 11/• 7rI6.AT THIU cub Page 4 of 11 u -RAE mm 1-lu Ra tONOC11SIIR. DAAEA 11.711 Es-ve n7u RETURN dU LT AIA All AAIRRSIDE 4m Iau 1 / nm nsa — N -ill 3e21 71-1H RA TAX RELIEF [1111 Sop brro rLON RMT AE,UAN ELECTRICAL HEAT O8K0000281 Page 4 of 11 Project: Glasshape Certified Drawing for 4t Unit Prepared By: 04/04/2016 04 54PM UXITEO J TO. DNIi COIINFR COAXER CORXCR COANCR TFCMroLOGIFb nu[R.T [`nm UNIT RI6NT RI6XT IAI RIBXi f61 RIGHT ICT RIGHT IDT C.G. NE IGNi CARR I[A Ase nlwe un Sn 165. IS. LBS. N6. 1t81.1 M. I NG. I 265. I R6. I 1 I y II I6NC 01 130 iii 720 3/ 111 SO IES 61 133 11 55 Ill I/P61 2/ J/1 1it61 10 1/6 [111] I5AC OS 511 211 110 le 116 11 112 11 1If 11 JI 1/1 11111 21 1/1 16261 I6 1/6 [1111 /6Af 00 531 ITS 111 it 156 10 155 it 112 fl J! 116 19131 IJ 1/i 15911 zl I6 1311] FORSTARDAID UNIT OTHER OPTIONS AID ACCESSORIEIGHT IS WITH S, REOW FER TAS O IN[ APR WITHOUT DATA CATALOG CORNER A CORNER B O F A y CORNER D I.- CORNER C A TOP ir 0 FRONT �" """`"' 48NC 0l -O6 SINGLE ZONE ELECTRICAL 48KC000281 .7". aF09-16-14 ITH GAS HEAT - COOLING W - Packaged Rooftop Builder 1.40 Page 5 of 11 Project: Glasshape Certified Drawing for 4t Unit Prepared B : 04/04/2016 04:54PM Service Clearance LOCATION DIMENSION CONDMMON 4A4n 1219 mm • UM N,— Is mwmed m rwl A 1B -In (457 mm) • No discm—t, i—ariL ce outlet option • 0.ecommended s A'edorarm 12dn 305 mm • Friar_dearance 42•In 1067 mm •Sx1m behhxl serMceris ounded e.., metaImam. rMs wa A 35an 914mm •Siafa bMrid servke Is electrical rlontrorrdudire e.., wood,flber lass tasdaces Nflue L Nn 10. .dung meshalr IM.M h.W C 3" 14mm • Side caMerNate dramis used 1 -in 457 mml mim— C1.1 - 1.1 a4&m 484n1219 mm •NofluedNc eaccas mstelled,surfl-11—bint6NmaterNl 424n 1067 mm •Sraha hemnd 3lnrkef is rounded e. ., metal, mas waA, another umt 0 36 -In 914 mm speclal •Sudaw hehirid servicer is elec I rwrvcorasuctise e..,wood,hber lass •� for adpcerRUNts m WAdhy mesh air Makes wANn l6 ft. of INS unit's _. __ _ _ _—.•.__ ._ ._... _._..___...,.,,......,...M,..,,..yy,..ar,ur cr,gneenng sor guoance on erry appflcatbn plamm" overhead obstnrtlan vvertkbl de..—. Packaged Rooftop Builder 1.40 Page 6 of 11 Performance Summary For 4t Unit Project: Glasshape 04/04/201E Prepared By: 04:54PIV Part Number:48KCDAO5A2A6-OAOAO ARISEER: ..............__..... .........-..... --........ -..... - - ....------_ ----- ----------- 14.00 Base Unit Dimensions UnitLength--------------------------- ----------------------- ..... _.._. Unit Width:. --------------- ----------------------- Unit -------- Unit Height:....... ...... --------------------------- ------------ ------._... --- ------ Operating Weight BaseUnit Weight: - ................ -------------------------------------------------------------_----- -- Medium Static Option Belt Drive:--- ------------ ----------------------------------------------- ............. - - Accessories Ultra LOW LEAK - Vertical EconoMi$er X with solid-state W7220 controller: Total Operating Weight:.----- ----------------------- ---- Unit Unit Voltage -Phase -Hertz:.....---------------------------- -------------- ------- -- AirDischarge:---------- -------------------- ------------------- ------------------------ FanDrive Type: ----------- ----------------------------------------- -----_._..- -------------- Actual Airflow:........- Site Altitude:------ -- ----- ------------ Heating Performance ------- _--------------------- ......74.4 in ------------ -- ----------- 46.8 in ------------------------- -- ... ------------ 33.4 in ..................------------ - ---544 Ib --------- --------------- --- ------- ....._---- _ 10 Ib ----------- --- - ............... .................50 Ib ------------------- ---- ------ .....604 Ib - -------- ---------- ---- 460-3-60 . ............_ - - --- ----- .--- ... - - - - -- 600 .. -------._------------------------------ ------ -- Vertical EnteringAir Temp:-- ---------- --- ...------------ ------ -- -- ---.....__---- ---------------------------------------- --------------- Belt F ----------------------------- ..... ..... ..--- ...._........----------- -------- ..-.....1600 CFM --- -- -------- ------------------------------- ...... Gas Heating Input Capacity: ------------------------ ---------------- ---------------- -- ......... - -- ....... - .-------- 95.0 F _...--------------------- --........... 80.0 F ... ...... ----.67.0 F --------------------------...--------------------------------------31.44 BTU/Ib ....... --....................... -----------58.3 F -------------------------- ------------------------- ------- __. - .... .57.4 F ----------------------------- -.......... - ---------------------- ---. 24.67 BTU/Ib .. -------------- ---- -------- ------ - --..48.73 MBH ------------------------------------- -......37.51 MBH ------------ ..................... ------------ .----------- ................... ------------ 4.00 kW ----- - - - - --- -----.146 HeatingAirflow:............ ------------------------------------------------------- ------ ------ --..--------- . ............_ - - --- ----- .--- ... - - - - -- 600 CFM EnteringAir Temp:-- ---------- --- ...------------ ------ -- -- ---.....__---- _1 .-- -----...----------------- ..................... ----------- 70.0 F LeavingAir Temp:.- --------------------------------------------------------------- ------ --- --------- .... - - --.........--------------- 104.1 F Gas Heating Input Capacity: ------------------------ ---------------- ..... -- - - 72.0 .... - MBH Gas Heating Output Capacity: _...._._ ................................ ------- . __. 0.0 159.0 MBH Temperature Rise: - - --- ----------------------- ----- -_------- - -- --------------....--- ------ .34.1 F Supply Fan Electrical Data VoltageRange:.. ------------------------------------------------------------- -------- ......_.._..--------------- . . ..................414.506 Compressor#1 RLA:------------ ------------------- ----------- ---------- ..---- .2 Compressor#1 LRA:----------------------------------------_-----------.------------------------- - --------------- --------------------------_------- -------------....41 --- - Outdoor Fan Motor Qty:........ ------- -- ----------------------------------------------- -----...----------- ------------------ 1 Outdoor Fan FLA (ea)--------------........----------------------------------------- -- --------------- - - _-- Indoor Fan Motor Type: ---------- _------------ ---------------------- ---.....0.8 ---- MED Packaged Rooftop Builder 1.40 Page 7 of 11 Performance Summary For 4t Unit Project: Glasshape 04/04/201E Prepared By: 04:54PIVI Control Panel SCCR: SkA RMS at Rated Symmetrical Voltage Acoustics Sound Power Levels, db re 10E-12 Watts Advanced Acoustics Advanced Accoustics Parameters 1. Unit height above ground: ................... _-- Discharge Inlet Outdoor 63 Hz 85.8 86.5 90.9 125 Hz 79.8 76.8 84.6 250 Hz 71.3 63.1 79.5 500 Hz 67.5 61.5 77.9 1000 Hz 64.1 60.9 76.5 2000 Hz 58.4 54.8 71.1 4000 Hz 59.9 50.2 66.9 8000 Hz 54.8 42.6 62.5 A -Weighted 71.1 67.0 81.0 Advanced Acoustics Advanced Accoustics Parameters 1. Unit height above ground: ................... _-- 30.0 ft 2. Horizontal distance from unit to receiver: ---------------- - 50.0 ft 3. Receiver height above ground: ----------------------------------- _----- 5.7 ft 4. Height of obstruction:-------------------------------------------------- ft 5. Horizontal distance from obstruction to receiver:..... 0.0 ft 6. Horizontal distance from unit to obstruction: ------- ---- 0.0 ft Detailed Acoustics Information ............. .. ---......2.5 .......... .-------- ----- - - ..... _0.26 -------- ---- ...--- --- ...--- ------------ ----- .......12 -- --------------- --------------- -------------- 15 -------------------------------------- ------ -------------11 .................... ---------- - .........61 ----------------- - --------- None Octave Band Center Freq. Hz 63 125 250 500 1k 2k 4k 8k I Overall A 90.9 84.6 79.5 77.9 76.5 71.1 66.9 62.5 92.4 Lw B 64.7 68.5 70.9 74.7 76.5 72.3 67.9 61.4 80.8 LwA C 58.5 52.2 47.1 45.5 44.1 38.7 34.5 30.1 60.0 L 32.3 36.1 38.5 42.3 44.1 39.9 35.5 29.0 48.4 L A Legend Packaged Rooftop Builder 1.40 Page 8 of 11 Performance Summary For 4t Unit Project: Glasshape 04/04/2016 Prepared By: 04 54PM A Sound Power Levels at Unit's Acoustic Center, Lw B A -Weighted Sound Power Levels at Units Acoustic Center, LwA C Sound Pressure Levels at Specific Distance from Unit, Lp D A -Weighted Sound Pressure Levels at Specific Distance from Unit, LpA Calculation methods used in this program are patterned after the ASHRAE Guide; other ASHRAE Publications and the AHRI Acoustical Standards. While a very significant effort has been made to insure the technical accuracy of this program, it is assumed that the user is knowledgeable in the art of system sound estimation and is aware of the tolerances involved in real world acoustical estimation. This program makes certain assumptions as to the dominant sound sources and sound paths which may not always be appropriate to the real system being estimated. Because of this, no assurances can be offered that this software will always generate an accurate sound prediction from user supplied input data. If in doubt about the estimation of expected sound levels in a space, an Acoustical Engineer or a person with sound prediction expertise should be consulted. 2D 00 00 FanCurve 05 1b 15 2D 25 35 46 AR W(CW-thwsands) RPM=1 107BEP=0.78MaxnntunRPM=2100 MaximumBHP=2.90 Note: Pleasecontactapphcationengineeringforselection outsidetheshadedregion. SC -System Curve RP-RatedPomt Packaged Rooftop Builder 1.40 Page 9 of 11 COPPflq 1 r \ \ 9M1*M �� 700FRN \ \ \ \�S.00BFP ` d AO" \ \ \1 42 BFP \ \\ 3OO;FM bOBFP 05 1b 15 2D 25 35 46 AR W(CW-thwsands) RPM=1 107BEP=0.78MaxnntunRPM=2100 MaximumBHP=2.90 Note: Pleasecontactapphcationengineeringforselection outsidetheshadedregion. SC -System Curve RP-RatedPomt Packaged Rooftop Builder 1.40 Page 9 of 11 Unit Feature Sheet for 4t Unit Project: Glasshape 04/04/2016 Prepared By: 04:54PM arrier WeatherMaker — 48KC PACKAGED ROOFTOP GAS HEATING/ELECTRIC COOLING UNITS -14 SEER 3, 4, 5 TONS Puron. coMruwKt� WEATHERMAKER SERIES WeatherMaker 48KC (14 -SEER) units are one-piece gas heating, electric cooling units that are pre -wired and charged with Puran (R-410) refrigerant They are factory tested in both heating and,cooling modes, and rated In accordancewith AHRI Standards 210240. WeatherMaker units are designed in accordance with UL Standard 1995, and listed by the Underwriters' Laboratories. Approved and certified by: w C US r ompemw.;ef , amnxw•ebMN>rry e�ma a.w..aore.o Certified to ISO 9D01 STANDARD FEATURES INCLUDE: ' Pumn (R4 10A) HFC refrigerant • Meets and exceeds ASHRAE90.1energyeffroiencylevels ' Scmi aamPressms with internal fine break and overload protection • Single -stage cooing capacity control • SEEf7s upto 14.0. EER'sup to 12.0 • AcutroP• refrigerant metering system • Exclusive noncorrosive composite condensate panin accordance with ASHRAE Standard 62, sloping design, side croenterdran • Standard coaling operation up to 115"F(46•C)and down to 40°F (41C) - down to 251F(4*C)we" winter startWd. • Pre -painted exteriorpanekand primer -coated interiorpanelstested to 500 hours salt sorry protection • Fully insulated cabinet • ExalusiveIGC said -state control for on -board diagnostics with LED error code designation bumercontrof logic and energy saving indoor fan motor delay • Low NOx models that meet California Air Quality Management • Induced draft gas heat combustion design • Redundant gas valves with up to two stages of heating • Low pressure and high pressure switch protected. MAINTENANCE FEATURES: • Acoesspanelkvhh easygrip handles • Innovative easy starting, no -strip screws on unit access panels • Twoynchdisposable return airfttersand Tbcl*ssfilter access door • Direct Dave —ECM indoormotoris standard with options[ belt drive systems • Temninal board facilitating simple safety circuit troubleshooting and simplified control box arrangement • Exclusive IGC soFd-state control for onboard diagnostics with LED error code designation, bumercentrol logic and energy saving indoor fan motor delay. INSTALLATION FEATURES: • Thnr-thebottompowerentrycapabAly • Single point gas and electric connections • Full perimeter base Tall with burlt-n f9gng adapters and forksbts • Field convertible from vertical to hor¢ontatakilow STANDARD WARRANTY: • 10-yearheatexohanger-15-yearstanlesssteel option • 5-yearaompressor • lryearparts • Many optional upgrades also available OPTIONS INCLUDE BUT ARE NOT LIMITED TO: • Paenieri-i nk and RTU Open Multi Protocol DDC Controls • Suppyand Return Air Smoke Detectors, high statncmotors • Louvered condenserooigusids • Disconnect switch and convenience outat options • Stainless Steel heat exchangeroption • Corrosion resistant cod coating. • High static motor options • Patented Humidi-MiZee adaptive dehunidrTication system. This option also ncludesMotonnaster I controls • liangedaccess panels • Integrated ecenommersystem. Standard and Ultra Low Leak versions For a complete rat of options and accessories referto the Product Data Catalog forthis unit. Packaged Rooftop Builder 1.40 Page 10 of 11 Spec Sheet for 4t Unit Project: Glasshape 04/04/2016 Prepared By: 04:54PM Packaged Rooftop Builder 1.40 Page 11 of 11 3 STRUCTURAL CALCULATIONS Glasshapes RTU 3425 South 116th Street, Suite 101 Tukwila, Washington APRIL 12, 2016 PREPARED FOR: Seattle Mechanical 899 West Main Street �C� . Auburn, Washington 98001 MAY 242016 CK, Oil Tt1wis BvI1.D1 M• 4 WASyf� PREPARED BY: Moore Engineering Group 21902 96th Avenue SE Snohomish, Washington 18959 tw R�L Gw`� Moore ��� �► Engineering �z t? Group %IAA*741 RECEIVED CITY OF TUKWILA MAY 10 2016 PERMIT CENTER GENERAL STRUCTURAL NOTES: �. AI.I, MATERIALS, WORKMANSHIP, DESIGN. AND +C`OW17RUCTION SHALL CON1rORM 'Ix) THESE NC)'n:...S AND THE Off RNATIONAl. RUII n[NG CODE (MCS 2012 M- 1-I10N. 2. DI--'sl(:N tk)ADJNG CRMTERIA: ROOT= LIVE LOAD ....... ............ . 25 PSI' MECHANICAL 11NIT ............. . ....... 869 POUNDS EARTHQUAKE....._.. .,..�.. e. �.._._.. Sus =0.963 SITF, CLASS D 10 E WIND ..................... ............ 85 MPK EXIK)Sl IRF' R 3. STRIJ(7rURAL C'.AL.GUL.A'IIONS ANI) SKF..T(.I S SHALL BE IJSFD IN MNJIJNC71ON WMI MECHANICAL DRAWINGS POR BIDDING AND CONSTRUCTION. C '1'RA("i'()R SHALL VERIFY DlwNSIONS AND CONDITIONS POP, C-OMPAT113MY AND SHALL N(Irl"IFY E NfTINFER OF ALL DISCREPANCIES PRIOR TO CONSTFtuC'I'I()N. 4. CONTRACTOR SHALL VERITY ALL EX[SrWi THMENSIONS. MEMBER S17FS AND CONDITIONS Pl IOR TO X)MMFNCING ANY WORK. AI , DIMENSIONS O1` EXIS'T'ING CONS CR( ICTI()N SHOWN APE- INI1?r DET) AS L'r(.JIf)ELINES ONLY AND MUST BF YF: U TIED. 7I1E EMSTING (X)NDFTIONS SHOWN ON THL SKVft;HF S ARE BASED ETT IE -R ON 8117, ORSERVATTON, ORIGINAL. DRAWINGS OR Wm- ASSUMED HA» FD ON FXPECTED CONDITIC)N4. 1 F THF, EXISTING C ONDri-IONS Ix) NOT CLOSELY MATC 14 THE CON SHOWN ON DIl:, SKI:11;,:[ F-5, OR IF TI -IE EXISTING MA'13 RTAI.S ARE OF QUESTIONA-Bix o Sl.IR STANDARD QUA Ll'I'Y:, NU'['IPY THE ENGINEER PRIOR To C)OMMFNCING ANY WORK. 5. CONTRACTOR SILkLL !PROVIDF. TEMPORARY BRACIN(, p()R T7 -Hi STRUCTLIRi AND STRUCTURAL (A)MPONIENTS UNTIL ALL FINAL c:ONN'F47TIONS 1 TAVG JaM-N COMPLETED IN ACCORDANCE WITH THE, T)RAVrjT1uS. 6. CC1L1F`17 ASC FOR SHALL IIERESPONSiBLE FOR ALL SAFETYPRECAUTK)NS ANF?T F . METHODS. TECHNIQUE—S, SFQUENCES OR P'ROCCE7t RNR RFQUIRED FOR TTJE COMP'L TION OF THE WORK. 3, S)Ils M METAL SCREWS SHALL (_:UNFORM TO 711E AMERICAN IRON AND STEEL :lN9iI7WL'* (AISO' SP1 CIFICATIONS I"OR THE. DM- GN OF COLD -FORMED S'IVFI, S*rRIJC: IZJRAI, MEMBERS". 8. CONNEC r INE UNIT TO TIIC E-XI91'ING MFsTAI. CURB WMI A MINIMUM OF (3) #10 SHFF.T' METAL SCREWS ON EACH STOE or. IIID UN I'I : PIACI; ONE SCREW AT fi ` To S FROM EAC+ i C ()RN1+R OF TIM UNIT AND -1 -1 -IF TH[RD SCREW AT APPROXIMATFLY T1 LE MIDDL E OF THE UNIT ON EACH SIDE. A Maori E'ri ine.e i ng roup PROJECT: I� Air SLE: 71� :SMS F-iDJCr DESCRiPrI N.- The Prat Consists of the replacement of two Witting rooftop mcchartical units with now units, LOAi1Sc TAVF 25 PSF DEAD Roofing and re-rwf 5 n DEAD f T,.IVE WIND SETS C EQUIPMENT Unit Existsng Curb Curb, Adapter Total 1/2 Plywood sheathing 2x6 0 2V ot. 4x1.4 @ W o�c, Insulation h+iEP Ceiling & Lights Tafel Dead 85 mph, Exposure 8 Latitude Lmq;itude Site Class, Sw (D) Existing M. s 574 115 689 pounds 1 r5 1.0 2.0 2.9 IFF 39 PSP 47-9W -1^.2.294 .DtoE WA ONfR 1,014 0_x}'12 0,963 Neter RTUs 604 115 719 pounds 74"W"x57" high Moore "WEC`. ENGW. KWM Engineering GLAssi i DATC 4/12/116 Group SCALE; SHEET 0mign Maps Summary Report Page 1 of 2 MUM Design Maps Summary report User—Specified Input Report Title Glass Shape RTUs Sdt ADn', 4, 701 f+ 17:16; l3 UTC Building Cade drat Document 2012 Intematlonai Building Code N'fLch USG5 11<l.'0rd data avri!ab'e in 2001x; Sita Coordinates h7.5°N, 122.294OW Sipe SOR Cla Ui nation Site Class D -"Stiff soil" Risk Category► IVIVIII . 00 %A Y!L S I.'BIKA� aE enton J' �IJI'111t1i .:. �, 'Y Vashaq -A,.,,, VA At TL i Maio* Valf.y USES—provided Output !9�= 1.5209 Sw= 1.5209 Sm= 1.0149 S, = 0.5 71. 9 56L ' = 4.857 9 S. = 0. 571 9 f=ar infoamat:lon rel how thw SS and S1 values above have teen ta".rsriaw Uvrn p7uba5ilisisc (nsk_targew) and detcrmdnt nc ground rnoUons In the dirertepn of rrta emurn itoraolltal response, pleasue rP.lctnt to the appixatmn and .W-P.d Thr,,' M9 WENRP bvildinf] code reference documeSAi_ l MCEa Response Spectrum Design Response Spectnrm TG 1.40 11, 1_10 1.44 6.99 1- 0.92 1.12 0.17 3 &SC d 0 i4 O.9V ass a.Li 0.44 0.40 o•IL � ort n p On 040 0..60 0.20 1. 0 1.29 1.40 1.0 J_t4 2_02 0 POFSO& T (slel PWia4L T Is") http:I/ehp T -earthquake_cr.us&s,pavId-siPmaWuslsummmy-php?templaoe=mini mW&kitiwd... 4/9f2A16 Design Maps Stumrwy Rcport Page 1 n C 2 MUM design Mapes Summary Report User -Sped Input Report Title Glass Shape RFUs sw April n, 7016 17.15:46 UTC Building Code Reference Document 2012.Inters monal Building Code (vr uch trHllarc EISC;S hMid daLd dvddeW"c as zwHj Site Coordinates 47.5°N, 127.294-W Site Sohl Classification SKL Class E —'Soft Clay Soil" Risk Category ]:lHAH .A 1iRiLW 4A V'4! f WVAP Iti $45 E �C•xfk•_ git� - 1 S�itli�lifl AN AAPOR Y ,I *RmtOn VA010 ti q Arr.€ - L Mapl* Valley US+GS•-Prov[&W Output Sr a f.S20 g Sm = 1.368 g SM = 0;512 g S. = 0.571 g S*. 1.371 g S6! 0.914 g Fvr InfonTLation On haw tlac SS and S1 values above have heon w1culated from probablnMlc (rl.*-tarydcd) and ftcrminisvc ground mobons In Me direcion 0 m=imum hor=tal respanfe. pitmse mtum to the appl�mLiCn and select the `2flM NFNRP- building code reference dacumftk. MCER Response Spectrum 1. to 1.2L l.lz 4.73 OLL`1 0.70 O.SC O d2 6.70 o.ao aao am ata 8.40 ntaf Ito i.3a 1,1a LQa 1.0 zoo Pe iD41(=ad .._ Design Response Spectrum a.w n.2a A40 OU 0n 1.00 1.20 I.aa 1.t3 L,CO ZW VWI&d. 7 (see) htipJfchpl-carthquskc.or.usg.govldesignmapslUs/wmmm-y.php?tcmplat�—minit ai&latitud... 4/9/2016 Physical data DAM Um as Houma taRGO� wum M UnAw �4 Sw ato Eft t 10 000oft Ce 3-M CONGEMMM se 611 q 0 cilias16 4 NOW 906 -- 1S 4009NDENB"M: 4106 % M L a ED TONFaRMAM(MIQ tib 1'.17 t817 2-17 ETAFCNU=R FM 1i}am 103L 18 Chu 10� 13�Q l2M IV Cft �Oee�,r.sI�p l4 ' SCID t4 240 N><akfl � t A8 CJD 1- i.� EAD to � �so E � T0104CM mm pwRF gum oftmdw AM — > 4 L&9A vy rum 45 C"ufirlfaSlOtf►! FkwiWr9mof _ _ /l �C 1A ASS JL.ap 141`ta5 N raw ftm Am {X4 Z-15 r 17 b6 44T S_ 15 4-1 asSo etas.► aft D1i+SM.D..alfa f.} ���fts AM13m —pMentttfft�>p tt� 1L1qm 4 .rC! ampIla 33 IOw tl fpj�ii���� r MMWmm ROMP 7�lip 00 to t � 16 16�A0a 11ee�1e %M& %35 as 1t1h itl 3L5 LS 35 as 8 QiLClOflaallJa$A}� .0 p 5 E LEDGM OW — tow tinaepwm `s t4be �L7 ofd ��oM1 014004 9�F 7* ae1. 7 014= 8ti11ti u� tfMM S I:rxA NM a 6ecas� treats UritModel: ...... � M*t - _.a"Z#7S' UFA Slues _ _ (Tetra) Urdt vUieth -� _ _3"0�m 1 A ow � 8vppy a rir6Gal;pfetrlrlai om I� <•• wklfs tee ommu m acr e, yid,,, SErQb uer p,*Oq App-imftwan 'a�sxw�t Fareeod debfedrk� C and Plum Re*um +Jr FEw Type:.,-.__ __ R8WMAJtFftrQLmnW. Rat�um Air FW* S-� _._� 16x23It 2 -LMKGeWOUMDM !Medan Std ovum m D" AlCu-AVCu Bug Eft mrd P=MgDV Wamidy mon 1 -Year(.} 4-Yeff p Mf$td.) 1C -Year heft Wmh9rOff- Akm*gwd(mw.) NO o were aid. Ntr1TE: Pieaae tem WUMIW CM109 SM -0a9 lw 9OWUMbn of radw See 0.00 rg'a Wwode.. tine kdonesum Mm- 3. 10 3.10 m"Y*Orr sr It�um�rons �r ae M Aa L4 I !!tl L4.mmson «o r L r I� L�6 ri Z-1$ MIO, rl MT tce Y n GK Illi �cii 1 1 t 'rl.�� ■�i'1 C'9CC 24'. CSJI:'/i:ll- • �%s�'a�rf{ am N t: Fin1 +�'c gat A . wit ut �C!-1:FJ1f � �. - cater/IiF4aa�k1 maw, AQ 8 1 �1 ROO= G*S*Wc Pefforinance Summary For 4-t Unit 04MIU2015 PWO" I* 04:s4pM PsrtNLwnbqr.48KCDA05A2AG_oAcAo AM SUR BUvftDMuwajw& LM Length: Unit Heowt- Qww"Welo am " Y"he Madon StM 0ow 9* omw A4*4**orbs Uhm LOW LEAK - WOW ecwooMisw x oft sab$• W7220 conrdlw, Toftfolwali MOO*—, - unit Uh*VbbqwMaw4trtr__ A!rDkdwgw- Fen Oft Typ&. Adisd Akftw. Gft Aftds.;.. C."Mo p"fennwMe 001*wMr Enft" Air DR — EvaVonftor Entaft Air 08% _ F:'wwowwEroorigAJr%W _ EvWotRtDrLevying AWM-.--__ BvVwgdor Lw*q Air WM . - Eor LwwV Air Enthalpy: cMf*c4oftcWow&f__- GM" aunt* cmaw__ CaMN"W Pftw b1put Gail Bypm Fe*r.- H F%domwnce HoW" Ajrfkw__ - EnkftAJrT&Tgt LWftAlrTempe Can Mo6v bpA cam2ty! G" "w3ft OUOA CAPORr— WOW Fan ExbwrW Smo pmsww 006= 1 Acmeswus, MW pnmm Emnombw_ TOWI Appfimlon Stg*-- (EV + UMR OpWA=� Fan RPM: - Fan Power: NOTE: _14M In __4LI in AM in JIM 6 'Fa by G" lb -ASO MA F ULD F _ ..07.0 F 34A4 UTUfM ML3 F F ffTLvb ..___4LTl M13H MBH -.---4A* M _low CRA _7LG F -IM.1 F _72.D M13H M13H Ul F --AN in mg -DAY in wg OXY inag Mip add rWRPURvrvwlw.-t3c: EkcbtW Daft voaw R*M9w____414 - IN ccnvnmw #I L2 OCPVrc=w#1 LRk_ OVOW Fan MworW_. Ou6dbor Fan FLA (any- Inwor F*n Vokkr Typw.— MW Pa&AWd Rooft Mw IA Page 7 ff-lT- 4�z i Eb cir—Bew f,77 -f c" �4 7) Tey' & 4kg:,(,4vlo "x - ,19&c -- Iori-tcspt L 4f nw* ei-J-1 Moore PFt omar. E n9in-eering Lo, Group SCALM, cli-6-? t 4kg:,(,4vlo "x - ,19&c -- Iori-tcspt L 4f nw* ei-J-1 Moore PFt omar. E n9in-eering Lo, Group SCALM, 5/1/2017 City of Tukwila Department of Community Development DAWNA PETET 899 W MAIN ST AUBURN, WA 98001 RE: Permit No. M 16-0074 GLASSHAPE 3425 S 116 ST - SUITE 101 Dear Permit Holder: Allan Ekberg, Mayor Jack Pace, Director In reviewing our current records, the above noted permit has not received a final inspection by the City of Tukwila Building Division. Per the International Building Code, International Mechanical Code, Uniform Plumbing Code and/or the National Electric Code, every permit issued by the Building Division under the provisions of these codes shall expire by limitation and become null and void if the building or work authorized by such permit has not begun within 180 days from the issuance date of such permit, or if the building or work authorized by such permit is suspended or abandoned at any time after the work has begun for a period of 180 days. Your permit will expire on 6/27/2017. Based on the above, you are hereby advised to: 1) Call the City of Tukwila Inspection Request Line at 206-438-9350 to schedule for the next or final inspection. Each inspection creates a new 180 day period, provided the inspection shows progress. -or- 2) Submit a written request for permit extension to the Permit Center at least seven(7) days before it is due to expire. Address your extension request to the Building Official and state your reason(s) for the need to extend your permit. The Building Code does allow the Building Official to approve one extension of up to 180 days. If it is determined that your extension request is granted, you will be notified by mail. In the event you do not call for an inspection and/or receive an extension prior to 6/27/2017, your permit will become null and void and any further work on the project will require a new permit and associated fees. Thank you for your cooperation in this matter. Sincerely, Bill Rambo Permit Technician File No: M16-0074 6300 Southcenter Boulevard Suite #100 e Tukwila, Washington 98188 9 Phone 206-431-3670 • Fax 206-431-3665 City of Tukwila Allan Ekberg, Mayor Department of Community Development - Jack Pace, Director December 28, 2016 Kelly Parfitt 899 W Main St Auburn, WA 98001 RE: Request for Extension #1 Permit Number M16-0074 Dear Ms. Parfitt, This letter is in response to your written request for an extension to Permit M16-0074. The Building Official, Jerry Hight, has reviewed your letter and considered your request to extend the above referenced permit. It has been determined that the City of Tukwila Building Division will be granting an extension to the permit through June 28, 2017. If you should have any questions, please contact our office at (206) 431-3670. Sincerely, Rachelle Ripley P Y Permit Technician File: Permit No. M1.5-0074 Tukwila City Hall - 6200 Southcenter Boulevard - Tukwila, WA 98188 - 206-433-1800 - Website: TukwilaWA.gov Attention: Building Inspector. I am submitting a written request for a permit extension on M16-0074. We had a Mechanical Inspection and Waiting on the electrical contractor to complete his work and finalize the electrical permit so we can finalize our mechanical permit. Thank You Kelly Parfitt Seattle Mechanical .w RECEIVED CITY OF TUKWILA DEC 2 0 2016 PERMIT CENTER 1 Request for Extension # _1 Current Expiration Date: 1 Extension Request: VApproved for / 0L d days ❑ Denied (provide explanation) SignaturePnitials 11/1/2016 City of Tukwila Allan Ekberg, Mayor Department of Community Development Jack Pace, Director DAWNA PETET 899 W MAIN ST AUBURN, WA 98001 RE: Permit No. M16-0074 GLASSHAPE 3425 S 116 ST - SUITE 101 Dear Permit Holder: In reviewing our current records, the above noted permit has not received a final inspection by the City of Tukwila Building Division. Per the International Building Code, International Mechanical Code, Uniform Plumbing Code and/or the National Electric Code, every permit issued by the Building Division under the provisions of these codes shall expire by limitation and become null and void if the building or work authorized by such permit has not begun within 180 days from the issuance date of such permit, or if the building or work authorized by such permit is suspended or abandoned at any time after the work has begun for a period of 180 days. Your permit will expire on 12/27/2016. Based on the above, you are hereby advised to: 1) Call the City of Tukwila Inspection Request Line at 206-438-9350 to schedule for the next or final inspection. Each inspection creates a new 180 day period, provided the inspection shows progress. -or- 2) Submit a written request for permit extension to the Permit Center at least seven(7) days before it is due to expire. Address your extension request to the Building Official and state your reason(s) for the need to extend your permit. The Building Code does allow the Building Official to approve one extension of up to 180 days. If it is determined that your extension request is granted, you will be notified by mail. In the event you do not call for an inspection and/or receive an extension prior to 12/27/2016, your permit will become null and void and any further work on the project will require a new permit and associated fees. Thank you for your cooperation in this matter. Sincerely, t Bill Rambo Permit Technician File No: M 16-0074 6300 Southcenter Boulevard Suite #100 • Tukwila, Washington 98188 • Phone 206-431-3670 • Fax 206-431-3665 PERMIT COORD COPY PLAN REVIEW/ROUTING SLIP PERMIT NUMBER: M16-0074 PROJECT NAME: GLASSHAPE SITE ADDRESS: 3425 S 116 ST X Original Plan Submittal Response to Correction Letter # DEPARTMENTS: A-74wc." s-p'Lh Building Division 6 Public Works ❑ PRELIMINARY REVIEW: Not Applicable ❑ (no approvallreview required) REVIEWER'S INITIALS: APPROVALS OR CORRECTIONS: Approved ❑ Corrections Required ❑ (corrections entered in Reviews) Notation: REVIEWER'S INITIALS: A$ - Fire Prevention DATE: 05/10/16 Revision # before Pen -nit Issued Revision # after Permit Issued Structural ❑ Planning Division ❑ Permit Coordinator Is DATE: 05/12/16 Structural Review Required ❑ DATE: DUE DATE: 06/09/16 Approved with Conditions e Denied ❑ (ie: Zoning Issues) DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: 12/1812013 IECS INC Horne Espafiol Contact. Safety & Health Washington State Department of i_ab©r & Industries IECS INC Page 1 of 2 Search l r '+t r A -Z .Index Help Daly I.& I Claims & Insurance Workplace Rights Trades & Licensing Owner or tradesperson PO Box 19252 SEATTLE, WA 98109-1252 Principals 206-939-9495 HUMPHREY, GEORGE, PRESIDENT KING County Doing business as IECS INC WA UBI No. Business type 601 639 846 Corporation License Verify the contractor's active registration / license / certification (depending on trade) and any past violations. Construction Contractor. Active. Meets current requirements. License specialties Heating/Vent/Air-Conditioning and Refrig (HVAC/R) License no. IECS***0440L Effective — expiration 11/13/1996-11/20/2016 Bond No bond accounts during the previous 6 year period. I.nsu......ra.nce ............ Nationwide Mutual Ins Co $1,000,000.00 Policy no. ACPACT07515636456 Received by L&I Effective date 07/29/2015 08/01/2013 Expiration date 08/01/2016 Insurance history Savngs ........i..... (in lieu of bond) $6,000.00 Received by L&I Effective date 11/20/2001 11/20/2001 Release date Impaired date N/A N/A Savings account ID Savings history Lawsuits against the bond or savings No lawsuits against the bond or savings accounts during the previous 6 year period. L&I Tax debts No L&I taz debts are recorded for this contractor license during the previous 6 year period, but some debts may be recorded by other agencies. https://secure.lnima.gov/verify/Detail.aspx?UBI=60163 9846&LIC=IECS * * * 044QL&SAW= 5/26/2016