Loading...
HomeMy WebLinkAboutPermit M16-0082 - MARINERS TEAM - UNIT CHANGE OUT13 F* "-� I �IL I m OR by 0 VA 51 1220 SOUTHCENTER MALL M16-0082 City of Tukwila ' Department of Community Development • 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Inspection Request Line: 206-438-9350 Web site: http://www.TukwilaWA.Rov MECHANICAL PERMIT Parcel No: 9202470010 Permit Number: M16-0082 Address: 1220 SOUTHCENTER MALL Issue Date: 6/8/2016 Permit Expires On: 12/5/2016 Project Name: MARINERS TEAM Owner: Name: WESTFIELD PROPERTY TAX DEPT Address: PO BOX 130940, CARLSBAD, WA, Address: , , , DESCRIPTION OF WORK: UNIT CHANGE OUT, CONNECTION TO EXISTING DUCT Valuation of Work: $12,000.00 Type of Work: REPLACEMENT Fuel type: Phone: (360) 362-7663 Phone: (360) 405-0723 Expiration Date: 12/27/2016 Fees Collected: $350.42 Electrical Service Provided by: PUGEST SOUND ENERGY Water District: TUKWILA Sewer District: TUKWILA Current Codes adopted by the City of Tukwila: International Building Code Edition: 92013 Contact Person: 2014 Name: TED HANKE Address: 5373 AUTO CENTER WAY, International Mechanical Code Edition: BREMERTON, WA, 98312 Contractor: 2014 Name: SULLIVAN HEATING & COOLING INC Address: 5373 AUTO CENTER WAY - STE 205, International Fuel Gas Code: BREMERTON, WA, 98312 License No: SULLIHC063QT Lender: Name: 0 Address: , , , DESCRIPTION OF WORK: UNIT CHANGE OUT, CONNECTION TO EXISTING DUCT Valuation of Work: $12,000.00 Type of Work: REPLACEMENT Fuel type: Phone: (360) 362-7663 Phone: (360) 405-0723 Expiration Date: 12/27/2016 Fees Collected: $350.42 Electrical Service Provided by: PUGEST SOUND ENERGY Water District: TUKWILA Sewer District: TUKWILA Current Codes adopted by the City of Tukwila: International Building Code Edition: 2012 National Electrical Code: 2014 International Residential Code Edition: 2012 WA Cities Electrical Code: 2014 International Mechanical Code Edition: 2012 WAC 296-4613: 2014 Uniform Plumbing Code Edition: 2012 WA State Energy Code: 2012 International Fuel Gas Code: 2012 ` 0 Permit Center Authorized Signature: Date: I hearby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulati 'g constru5tion or the performance of work. I am authorized to sign and obtain this development permit gyee to JF# conditions attached to this permit. Signature: Print Name: Date: `b This permit shall become null and void if the work is not commenced within 180 days for the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. PERMIT CONDITIONS: 1: Work shall be installed in accordance with the approved construction documents, and any changes made during construction that are not in accordance with the approved construction documents shall be resubmitted for approval. 2: All permits, inspection record card and approved construction documents shall be kept at the site of work and shall be open to inspection by the Building Inspector until final inspection approval is granted. 3: The special inspections and verifications for concrete construction shall be as required by IBC Chapter 17, Table 1705.3. 4: All construction shall be done in conformance with the Washington State Building Code and the Washington State Energy Code. 5: Remove all demolition rubble and loose miscellaneous material from lot or parcel of ground, properly cap the sanitary sewer connections, and properly fill or otherwise protect all basements, cellars, septic tanks, wells, and other excavations. Final inspection approval will be determined by the building inspector based on satisfactory completion of this requirement. 6: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206-431-3670). 7: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center. 8: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. 9: `MECHANICAL PERMIT CONDITIONS' 10: All mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center (206/431-3670). 11: All permits, inspection record card and approved construction documents shall be kept at the site of work and shall be open to inspection by the Building Inspector until final inspection approval is granted. 12: Manufacturers installation instructions shall be available on the job site at the time of inspection. 13: Readily accessible access to roof mounted equipment is required. 14: The attached set of mechanical plans have been reviewed by The Tukwila Fire Marshals Office and are acceptable with the following concerns: 15: H.V.A.C. units rated at greater than 2,000 cfm require auto -shutdown devices. These devices shall be separately zoned in the alarm panel and local U.L. central station supervision is required. (City Ordinance #2437) 16: H.V.A.C. systems supplying air in excess of 2,000 cubic feet per minute to enclosed spaces within buildings shall be equipped with an automatic shutoff. Automatic shutoff shall be accomplished by interrupting the power source of the air -moving equipment upon detection of smoke in the main return -air duct served by such equipment. Smoke detectors shall be labeled by an approved agency for air -duct installation and shall be installed in accordance with the manufacturer's installation instructions. (IMC 606.1, 606.2.1) 17: Remote indicator lights are required on all above ceiling smoke detectors. (City Ordinance #2437) 18: Duct smoke detectors shall be capable of being reset from a single point near the alarm panel. (City Ordinance #2437)- 19: Duct detectors shall send a supervisory signal only upon activation. (City Ordinance #2437) 20: All new fire alarm systems or modifications to existing systems shall have the written approval of The Tukwila Fire Prevention Bureau. No work shall commence until a fire department permit has been obtained. (City Ordinance #2437) (IFC 901.2) 21: An electrical permit from the City of Tukwila Building Department Permit Center (206-431-3670) is required for this project. 22: Contact The Tukwila Fire Prevention Bureau to witness all required inspections and tests. (City Ordinances #2436 and #2437) 23: Any overlooked hazardous condition and/or violation of the adopted Fire or Building Codes does not imply approval of such condition or violation. 24: These plans were reviewed by Inspector 511. If you have any questions, please call Tukwila Fire Prevention Bureau at (206)575-4407. PERMIT INSPECTIONS REQUIRED Permit Inspection Line: (206) 438-9350 1400 FIRE FINAL 0703 MECH EQUIP EFF 1800 MECHANICAL FINAL 0609 PIPE/DUCT INSULATION 0705 REFRIGERATION EQUIP 0701 ROUGH -IN MECHANICAL 0702 SMOKE DETECTOR TEST o CITY OF TUK. -4 Community Development Department Permit Center W 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 '4411110''' http://www.TukwilaWA.gov SITE LOCATION Site Address: Tenant Mechanical Permit No. Project No. ''AA Date Application Accepted: P1 Date Application Expires: or office use only) MECHANICAL PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. "please print" PROPERTY OWNER NameA sf S g. Ick Address: ap City. 1 Nl/ . State; i) Zi CONTACT PERSON — person receiving all project Communication Name: _.._. ht Address: City: State: Zip: Phone'? 11� an 4nr Email: r .......... ❑ G King Co Assessor's Tax No.: Suite Number: New Tenant: Floor: ❑ ..... Yes .No MECHANICAL CONTRACTOR INFORMATION Company Name: Su p ' VIA Address: S 3 7 fit. City: State: Zi!. Pho e: r D s, O ax: Contr Reg No.: 0 ate: 1 Tukwila Business License No.: Valuation of project (contractor's bid price): $% R MPPD Describe the scope of work in detail: fAn j .�, Chawl5 ,I+ G J)n t41 h } 40 C,C �J rr ✓ q ID kc t Use: Residential: New .......... ❑ Replacement ........ ❑ Commercial: New .......... ❑ Replacement ....-.. g Fuel Type: Electric..... ❑ Gas ....... ❑ Other: H:Wpplications\Forms-Applications On Line\2016 Applications\Mcchanical Pemtit Application Revised 1-4-16.docx Revised: January 2016 Page 1 of t bh 09 Indicate type of mechanical work being installed and the quantity below: Unit Type Qty Furnace <100k btu Residential, Nighttime Furnace >100k btu Industrial Floor furnace 55 dB(A) Suspended/wall/floor mounted heater 57 dB(A) Appliance vent Commercial Repair or addition to heat/refiig/cooling system 47 dB(A) Air handling unit <10,000 cfin 65 dB(A) Unit Type Qty Air handling unit >10,000 cfin Residential, Nighttime Evaporator cooler Industrial Ventilation fan connected to single duct 55 dB(A) Ventilation system 57 dB(A) Hood and duct Commercial Incinerator — domestic 47 dB(A) Incinerator — comm/industrial 65 dB(A) Unit Type Qty Fire damper Residential, Nighttime Diffuser Industrial Thermostat 55 dB(A) Wood/gas stove 57 dB(A) Emergency enerator Commercial Other mechanical equipment 47 dB(A) 60 dB(A) 65 dB(A) Boiler/Compressor Qty 0-3 hp/100,000 btu 3-15 h /500,000 btu 15-30 hp/1,000,000 btu 30-50 hp/1,750,000 btu 50+ h /1,750,000 btu Noise: Mechanical units need to be in compliance with the Tukwila Noise Code. Maximum permissible sound levels are based on from where the sound is created and where the sound is heard. Additionally, if sound can be heard from within a house at night in a residential zone it may not be allowed. For more details, see TMC 8.22 District of Sound Producing Source District of Receiving Property Residential, Daytime* Residential, Nighttime Commercial Industrial Residential 55 dB(A) 45 dB(A) 57 dB(A) 60 dB(A) Commercial 57 dB(A) 47 dB(A) 60 dB(A) 65 dB(A) Industrial 60,dB(A) 50 dB(A) 65 dB(A) 70 dB(A) *Daytime means 7AM-I OPM, Monday through Friday and 8AM-1 OPM, Saturday, Sunday and State -recognized holidays. A few sounds are exempt from the noise code, including: Warning devices; Construction and property maintenance during the daytime hours (lam -1 Opm); Testing of backup generators during the day. PERMIT APPLICATION NOTES - Value of construction — in all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the permit center to comply with current fee schedules. Expiration of plan review — applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The building official may grant one extension of time for additional periods not to exceed 90 days each. The extension shall be requested in writing and justifiable cause dem6nstrated. Section 105.3.2 International Building Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. Day Telephone: 3( n H:\Applications\Fomm Applications On Line\2016 ApplicationsWechanical Permit Application Revised 1-4-16.docx Revised: January 2016 Page 2 of 2 DESCRIPTIONS ACCOUNT QUANTITYPAID PermitTRAK $350.42 M16-0082 Address: 1220 SOUTHCENTER MALL Apn: 9202470010 $350.42 MECHANICAL $336.94 PERMIT ISSUANCE BASE FEE R000.322.100.00.00 0.00 $32.50 PERMIT FEE R000.322.100.00.00 0.00 $237.05 PLAN CHECK FEE R000.322.102.00.00 0.00 $67.39 TECHNOLOGY FEE $13.48 TECHNOLOGY FEE TOTAL+ ' R000.322.900.04.00 0.00 $13.48 i Date Paid: Thursday, May 19, 2016 Paid By: THEODORE HANKE Pay Method: CREDIT CARD 044541 Printed: Thursday, May 19, 2016 11:43 AM 1 of 1 (r11 SYSTEMS INSPECTION RECORD Retain a copy with permit I M16 "60�2 INS ECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Project: �e Type of Inspect�io : Address: Date Called: 220 L pecial Instructions: Date Wanted: 7116 p. . Requester: Phone No: 3Gd - 0 Approved per applicable codes. 11 Corrections required prior to approval. I paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. INSPECTION RECORD Retain a cop;/ with permit INSPECTION NO. PERM! TI NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit. Inspection Request Line (206) 438-9350 Project: Type of Inspection: aMMe► �' Address: Date Called: )= 5QJjM4dCA)TW &4 11 - Special Instructions: . Date Wanted&7,& P.m, Requester: Phone No: o- RApproved per applicable codes. LJ Corrections required prior to approval. Inspector: Date: REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call. to schedule reinspection. INSPECTION RECORD Retain a copy permit ermit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Approved per applicable codes. LJ Corrections required prior to approval. I paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. A41 .i I pop m ��Q m s� m r Harbor Consulting Engineers, Inc. STRUCTURAL ENGINEERING CALCULATIONS for the MARINERS TEAM STORE ROOF TOP HVAC UNIT REVIEWED FOR CODECOMPUANCE i APPROVED JUN 0 3 2016 City of Tukwila BUILDING DIVISION REPLACEMENT Westfield Southcenter Mall Tukwila, WA ,y SCOTT jQ WA L1444177600'- IONALti�G 17 May 2016 Prepared for: Westfield, LLC Contact: Mr. Wayne Johnson, A.I.A. 2800 Southcenter Seattle, WA 98188 Tel: (206)-714-3485 Prepared bv: Harbor Consulting Engineers, Inc. 3316 Fuhrman Avenue East Suite 250 Seattle, WA 98102 BILE RECEIVED CITY OF TUKWILA t;Ay 19 2016 PERMIT CENTER 3316 Fuhrman Avenue East Suite 250 • Seattle, Washington 98102 • Telephone 206.709.2397 • Facsimile 206.709.2398 Harbor Consulting Engineers, Inc. INDEX TO STRUCTURAL CALCULATIONS: ITEM: Structural Installation Design --------------------- PAGES: S1 -- S5 Structural Installation Details ----------------------------- ----------------------------- D1-- D5 HVAC Unit Reference Materials----------------------------------------------------.--- R1— R11 index 3316 Fuhrman Avenue East Suite 250 • Seattle, Washington 98102 • Telephone 206.709.2397 • Facsimile 206.709.2398 �i r O g C.- -SpJ' ItiP % c- L ' G7 his le e� = Q, 8g-1 k vc-XA��lv ii 25 F/ M14 = /, 6 S,l 1P We = /, L (h a) (/, Z, 4)(. 3SA ) = 2. '7k E V = � 0, 2 Sv r We = 4, 2 (z o) (i 3 S" k ) = 0, 27 k ASG::' . J-/SA11 C J57h = 0.7 _ = 0,5-,91 /c E v = 0,7 (C-4 0,7( 0, 27kJ '=7 0, / 89k BYD� J7o/vte: /(' M" i6 Z- 1,,A 7-101V Checked: Date: Job #: HARBOR CONSULTING ENGINEERS, INC. Seattle; Washington Phone: (206) 709-2397www.harborengincers.com Scale: Sheet: ze y�rz/� 1�v'+C O g C.- -SpJ' ItiP % c- L ' G7 his le e� = Q, 8g-1 k vc-XA��lv ii 25 F/ M14 = /, 6 S,l 1P We = /, L (h a) (/, Z, 4)(. 3SA ) = 2. '7k E V = � 0, 2 Sv r We = 4, 2 (z o) (i 3 S" k ) = 0, 27 k ASG::' . J-/SA11 C J57h = 0.7 _ = 0,5-,91 /c E v = 0,7 (C-4 0,7( 0, 27kJ '=7 0, / 89k BYD� J7o/vte: /(' M" i6 Z- 1,,A 7-101V Checked: Date: Job #: HARBOR CONSULTING ENGINEERS, INC. Seattle; Washington Phone: (206) 709-2397www.harborengincers.com Scale: Sheet: I A 189 - o, 6 0) Fm = 7 7 3, 5 # Do wa wA-zD FL- 15 2, S # V PLr F'r it = 5 9 I FL- Fn off, zt?-f S9/ z.)zi M�eirnv n� De7 w� r✓Po� a L o,�--vi.,.� � -� +Fc. 4- 4-z'mA S9! W7) -) 54(2.1/ + F, (4.Z) = c FR = J 23Z ' pa w, FL = 3 0 C, 5 -ir wap V = S 9 1 .,I,*- k) aVe, 2 0.-j 1-,4 c. o �..��= 59 / # t/ oe� a or✓TA� sji�=�rR ! z � Atti/', 57 -ORE 9 C- �S �oy.,/�T�Nuat �l//1/6 ROOF To � / " Sr/1 —10"VChecked: Date: Job #: JTFQ HARBOR CONSULTING ENGINEERS, INC. Seattle, Washington Phone: (206) 709-2397 www.harborengineers.com Scale: Sheat: 521,5-5 � V'A 11.5- 0, Yv -!5, J: 4' z -JpF 9L Z 95 k - WSB Date: �xwl'7- //v Checked: Date: HARBOR CONSULTING ENGINEERS, INC. Job #: Seattle, Washington Phone: (206) 709-2397 www.harborengincers.com Scale: Sheer. H -Series • 5 - 239 STANDARD LOAD TABLE OPEN WEB STEEL JOISTS, H -SERIES Allowable total safe loads in pounds per linear foot based on allowable stress of 30,000 psi Joist Designation 141-13 141-14 141-15 14H6 14H7 16H4 16H5 16H6 16H7 16H8 *Depth in Inches 14 14 14 14 14 16 16 16 16 16 Resisting Moment in Inch Kips 165 212 259 307 369 221 289 344 413 478 Maximum End Reaction in Pounds 3200 3500 3800 4200 4600 3800 4300 4600 4900 5200 **Approximate Weight in Pounds per Foot 5.5 6.5 7.4 8.6 10.0 6.6 7.8 8.6 10.3 11.4 - Span in Feet 14 457 500 543 600 657 15 427 467 507 560 613 16 400 438 475 525 575 475 538 575 613 650 17 376 412 447 494 541 447 506 541 570 612 346 _ 18 340 389 422 467 511 422 478 511 544 578 292 354 19 305 368 400 442 484 400 453 484 516 547 248 301 364 437 399 20 275 350 380 420 460 368 430 460 490 520 212 258 312 374 435 342 413 21 249 320 362 400 438 334 410 438 467 495 183 223 270 323 375 295 357 429 22 227 292 345 382 418 304 391 418 445 473 159 194 235 281 326 257 310 373 434 23 208 267 326 365 400 279 364 400 426 452 _. _..___......._..... 140 _ 191 169 .... 245 205 . _ 300 246 ....» 350 286 ..... ,. 383 225 272 326 379 434 24 256 334 383 408 1 433 m 123 149 181 1 217 251 198 239 287 334 382 25 176 226 276 327 368 236 308 367 392 416 109 132 160 191 222 175 211 254 295 338 26 163 209 255 303 354 218 285 339 377 400 96 117 142 170 198 155 188 264 226 X315 ! 262_ 363 300_ 385 27 151 194 237 281 337 �202� 86 104 127 152 176 139 168 201 234 268 28 140 180 220, 261 314 188 246 293 350 371 77 94 114 136 158 124 150 181 210 240 29 175 229 273 327 359 112 135 162 189 216 30 164 214 255 306 347 101 122 147 171 195 31 153 200 239 287 332 91 111 133 155 177 32 144 1 188 224 269 311 83 101 121 141 161 W fi-V A�hT of fiE'a.�pJr h'��� vivit YV/l XZZ 436 1 f So Z So Z- JF Z.9, 0 F'a . 4L = /-7'S-f# 9Gcoo Rk- 91Q3 x /Z 32CzgJ r 3v6S(J9,8i (? , 2 i J93 34>268 vpf J� of G/ /a000 G l 3,7 ( laoG+S 0, 949 = o- 2 90�:? = 6 G D 7`✓Z 0 0 (Q kV / 5` h Z?- A 3 l- F�A-M 4,,A7r-- Tom' Syt�F7arzT Pl2®i�OJ'E� L/Y!� G li�v/�` L.. � /�7,��-✓ �' lam✓/Ty! �l�G, c- .�C, t S L t��.Datc: ll 00F TQA GAN/ 1" /�v i�tGG�%I T/ O/V ;���ti«,: Mac: HARBOR CONSULTING ENGINEERS, INC. Seattle, Washington Phone: (206) 709-2397 www.harborengineers.com `kale: Sheet: S� -El s5 YRoPasEv f/Y.R c E/N/T NOTA; I LA�i or% C) /"✓�%/ 44/mss L 3 k 3 x.3/8 ,A 3 6 JU PPS McA4,06R, «1 lNl� `X2`2 1�YESTPi� sovey cC.,.7�2 ?vi�w���, w�, J'� v v v, o 'o V 111:11AR43 oR MAY 209 .v/ IA05 /v07.z-- 11 3W3"12"'4 x 5z A q e /C L R00,45- 77 0,o-1 GL -/P e /Z "O. C' op/,P,A �r//-'/4 klr-14'aT 1 'P4-�7? h1�Co z2e'e4s MA,VV,11:AcT,v,ehw S- C'61,Ce$ WY7A1 RVe Ax))r-4,oe C61 -vi- cv";Po /a >r 7-0 /E'0 014:"- -Z)E-G k � F, - fly: Date: Checked: Date: HARBOR CONSULTING ENGINEERS, INC. Job #: Seattle, Washington Phone: (206) 709-2397 wwwharborengineers,com Scale: Sheet: Na?c /� ,�LTQ�N� C�i'✓NEC T/ON :' �. �JlliiG (.>N//' /r✓ST Gi'4 L 3`g ��y�/,G� �c ,y " / � �.� # Td T/1 L ..5 �•f' � h/ �S C*� /,6 "D, C; /r,l P,��13�� CJP&�'.�?7niGJ' ,l-/aG�S (/P ��'D�y Ar✓�c.� i„/?-� W�l�f/y'� P�7P Coiv�'�CTlo�vs Pe "(0 12 x 2 %2 S, s - ►'✓O 0'p . S�r.F% ry S P, i. -fix( 01--#2 cc/vi- C L44p'8 P. T, 2 '< 2 t%'r s'EC i/ oma/ W57- NIAz�s .To`�-vsfio.�!ate1710r.,ty r6 Checked: Date: G/ Jib #: HARBOR CONSULTING ENGINEERS, INC. Seattle, Washington Phone: (206) 709-2397 www.harborengineers.corn sate: sheet: I-111AC vAilr �✓- �'` GOrvN�C<Jo�s '`� PES MPGR r ,C'/r YV/ G3 -oma•,,, 65:� o, rv, s,,;r, / ..,....__._ cow. vv/ !v .66Eftm s�cT. a,v TU ee AAM W.5 7- illtC Date: Checked: Date: KTTa HARBOR CONSULTING ENGINEERS, INC. Job #: Seattle, Washington Phone: (2016) 7119-2397 www,harborengineers.eoni Scale: Sheet: p�/p7 FE/ TV,;'C- t ��) p, ✓v. 5 3- ,96S' PES' F'4,41V L. 31"( ax 3/e A-;36 KAI tilgNvF.�cTvc�4s G491V^f Pct Air(:FR #/2� YYQar� sce�r�Ss G'ovT GvRB P. i 2 x v/ '9� v 111 "VIA x ri L A � ..s?'A-� Y*V -s' y/G'1oc /r-1CR' C--�jOl2C—D �-I L f' 3/g x 3 x L F" ; 7-y W/ (9) - 5/8 '01A oGT�f Aj sil o"ev s « B c�i-nn C G -A l P �--� �Secrooy ,A -A 3 Gko)er� 51,v4ce L AA/�I-E 121pp R T TO ��) O V115'7 w5 IW ARWL— 's S i a/4E �-/ 1r'�t G ins.. Dale: D (-. � / /z, -5' Checked: Dale,: Joh #: HARBOR CONSULTING ENGINEERS, INC. Seattle, Washington Phone: (206) 709-2397 www.harborengineers.eorn scale: Sheet: Z /) 57S f' 3/g x 3 x L F" ; 7-y W/ (9) - 5/8 '01A oGT�f Aj sil o"ev s « B c�i-nn C G -A l P �--� �Secrooy ,A -A 3 Gko)er� 51,v4ce L AA/�I-E 121pp R T TO ��) O V115'7 w5 IW ARWL— 's S i a/4E �-/ 1r'�t G ins.. Dale: D (-. � / /z, -5' Checked: Dale,: Joh #: HARBOR CONSULTING ENGINEERS, INC. Seattle, Washington Phone: (206) 709-2397 www.harborengineers.eorn scale: Sheet: Z /) i SUBMITTAL DATA For: Quotation Order #: Date: 01/29/2016 Project: SOUTHCENTER TEAM RTU Project #: RWS01292016-04 Location: WASHINGTON Purchaser: SULLIVAN HEATING -TED Submitter: YORK NW -RYAN unitarySales loos vl .b,9.0 Information is subject to change without notice. Check local codes. Printed 01 rMo16 /e/ Al Date 01/29/2016 Project Name SOUTHCENTER TEAM RTU Project Number MYORK RWS01292016-04 Client / Purchaser SULLIVAN HEATING-TED Submittal Summary Page Qty Tag # Model # Description 1 XP090C00B2B1 BAA1A1 7.5 Ton, Single Packaged R-410A Heat Pump, Standard Efficiency, 11.2 EER / 12 JEER / 3.35 COP, Two Stage Cooling, No Factory Installed Electric Heat, 208/230-3-60, Standard Evaporator Coil, Standard Cabinet with Composite Drain Pan • 1.5 HP Standard Static Belt Drive Blower • Dry Bulb Low Leak Economizer w/Barometric Relief and Hoods (Bottom or Horizontal End Return Only) • Standard 2" Throwaway Filters • Copper Tube/Aluminum Fin Condenser Coil • Phase Monitor • Simplicity® SE Controller with Discharge Air, Return Air, and Outside Air Sensor {1l t:t)4 i X Roof Curb 44' H I Ft t, Urttrlsula Fu!! f'er rll to ,�Stt�pp d ..� Focket9iDPwn} .....s> �.a., �.. _2 1 2TP04532425 24 kW 2081230-3 Electric Heat Equipment start-up and commissioning by a factory trained technician is recommended. Contact your supplying distributor or sales representative for additional information & guidance. Unitary Sales Tool 0.5.9.0 Information is subject to change without notice Check local codes. Printed 01129/2016 Re/!V// Single Package R -410A Heat (Pump Project Name: SOUTHCENTER TEAM RTU Unit Model #: XP09000OB2131 BAA1A1 Quantity: 1 System: XP090C00B2B1BAA1A1 coming h•errormance 1 Total capacity 94.9 MBH Sensible capacity 68.7 MBH Refrigerant type R-41 OA Efficiency (at ARI) 11.20 EER Integrated eff. (at ARI) 12.00 IEER Ambient DB temp. 95.0 °F Entering DB temp. 80,0 °F Entering WB temp, 67.0 °F Leaving DB temp, 58.8 °F Leaving WB temp. 57.0 °F Power input (w/o blower) 7.30 kW Sound power 83 dB(A) Heat Pump Performance Ambient DB temp. 47 •F Capacity @ 47 °F 88.00 MBH COP @ 17 °F 2.25 COP @ 47 °F 3.35 Ca acity Cad 17 °F ............__..... _........ ...._.__..........___- 51.00 MBH Heating Performance Entering DB temp. 60 °F Heating output capacity (Max) 81,8 MBH Nominal electric heat 24 kW Applied electric heat 24.0 kW Installed Field Supply air 3000 CFM Leaving D8 temp. 85,2 °F Air temp. rise 25,2 °F Stages 2 Supply Air Blower Performance Supply air 3000 CFM Ext. static pressure 0.6 IWG Addl. Unit Losses (Options/Accessories) 0.46 IWG Blower speed 964 RPM Max BHP of Motor (including service factor) 1.73 HP Duct location Bottom Motor rating 1.50 HP Actual required BHP 1,65 HP Power input 1.54 kW Elevation 0 ft. Drive type BELT Electrical Data Power supply _ 230-3-60 Unit min circuit ampacity 112.4 Amps Unit max over -current protection 125 Amps Dimensions &Weight Hgt 51 in. Len 89 in. Wth 59 in. Weight with facto installed options 1185 lbs. Clearances Right 12 in. Front 36 in. Back 36 in. Ton 72 in. Rnttnm n in 1 oft zFZ in Note: Please refer to the tech guide for listed maximum static pressures 7.5 Ton • York Predator units are manufactured at an ISO 9001 registered facility and each rooftop is completely computer -run tested prior to shipment. Unit Features • Unit Cabinet Constructed of Powder Painted Steel, Certified At 1000 Hours Salt Spray Test (ASTM B-117 Standards) • Through -the -Curb and Through -the -Base Utility Connections • Full perimeter base rails with built in rigging capabilities • Hinged Access Panels • Standard Cabinet with Composite Drain Pan • Scroll Compressors • Dual refrigerant circuits for efficient part load operation • Two Stage Cooling • Solid Core Liquid Line Filter Driers • Copper Tube/Aluminum Fin Condenser Coil • Standard Evaporator Coil • Field Installed Electric Heat • 1.5 HP Standard Static Belt Drive Blower • Unit Ships with 2"'Throwaway Filters with a Standard Filter Rack that will Accept up to 4" Filters • Single Point Power Connection • Dry Bulb Low Leak Economizer w/Barometric Relief and Hoods (Bottom or Horizontal End Return Only) • Short Circuit Current: 5kA RMS Symmetrical Standard Unit Controller: Simplicity Control Board • An Integrated Low -,Ambient Control, Anti -Short Cycle Protection, Lead -Lag, Fan On and Fan off Delays, Low Voltage Protection, On -Board Diagnostic and Fault Code Display. Allows all units to operate in the cooling mode down to 0 °F outdoor ambient without • Safety Monitoring - Monitors the high and low-pressure switches, the freezestats, the gas valve, if applicable, and the temperature limit switch on gas and electric heat units. The unit control board will alarm on ignition failures, safety lockouts and re BAS Controller • Simplicity SE Controller with Discharge Air, Return Air, and Outside Air Sensor Warranty • One (1) Year Limited Warranty on the Complete Unit • Five (5) Year Warranty - Compressors and Electric Heater Elements inrormanon is sugect to change without notice, Check local codes, Punted 01/29/2016 R3/ 9// N Single Package R -410A Heat Pump Project Name: SOUTHCENTER TEAM RTU Unit Model #: XP090C00B2B1BAA1A1 If Quantity: 1 System: XP090C00B2B1BAA1A1 Factory Installed Options XPO9000OB2B1 BAAW Product Category: Nominal Cooling Capacity: Heat Type and Nominal Heat Capacity: Airflow: Voltage: Economizer / Damper: Service Options: Sensor Options: Controlls: Refrigeration: Additional! Options: Cabinet Options: Product Generation: 1 RC0471 - Roof Curb - 14" High, Flat, Uninsulated, Full Perimeter (Shipped Knocked Down) (135.0 lbs) 2TP04532425 - 24 kW 208/230-3 Electric Heat (30.0 lbs) Unitary Sales Tool vl.5 9.0 Single Packaged R-41 OA Heat Pump, Standard Efficien0y 11.2 ESR / 12 IEER 13.35 COP 7.5 Ton Two Stage Cooling No Factory Installed Electric Heat 1.5 HP Standard Static Belt Drive Blower 208/230.3.60 Dry Bulb Low Leak Economizer w/Barometric Relief and Hoods (Bottom or Horizontal End Return Only) SimplichyS SE Controller with Discharge AIr, Return Air, and Outside Air Sensor Copper Tube/Aluminum Fin Condenser Coil Standard Evaporator Coil Standard 2" Throwaway Fitters Phase Monitor Standard Cabinet with Composite Drain Pan Field Installed Accessories Inionn8tl0n is subject to change without notice Check local codes. I a�nano�� R51 R1, ......... � tii +hE',»Uy5 e.Av�ffi 1Lt'. to ca M rr;w l�•�,K� ,w-IH CD ei 0 U bM b. VJl t•. iib b w i`• 6n �'M fM f � I � 4, � e r+� z � i I t � 4 � 0% owZC C. X d X !£II Y7 M,.-1 iii ; �: 1 .E< £ : .I fW a•t O � � W ' � tKS vb v7 W aG ux.ut� w�✓. +`-1 .. ryr _, �. ! ' 4J Xt 0. 41G�v tlT4C 03 (aD (�Eiq ca3,U3• � � � i zs xot�lm+m m m mjw I y. Q CL asmv. m u FJ eCm MQa..b 's I�€'fi" U M t/i ui Rl+ A/�J1 4fi '• �' 1 � 'i � CLfla � iSSJ E � W: "�b .J9 to 1 3 [C -. _SCK w^' E - E £ '�..p�. }• I...- I _ _ _...... _i IT (�'# w w w 0 +M W HO 2j dna �� QJVI OMI--I H � W33 F wjm NwV �mVl O �O Q U�Vn m JWOSS '2 W bd... .. L,�w0 J Ot4pNO i alb iaxxnom vr. W i d € :� V u¢O VZOHO ZA LLQt—HUN02 ar !~y J $ ��w 000F-wom>ar4 a dzo ff'f�••d W ar �✓x-i¢`�'�... i•'O.mtrt,�MMtmt Oi ¢W QUM= Z ZMQviwwn `«0,0 i i•' 7 �- O o r-v,w 4,- ovar t{ 32 •• S ¢g 'VZ�N�MOZ Hit +F� ~ � �: � o4w �ry� ar»O�w.�r-z o ar ,z„ [j arcs f �N G T gtzi+a oo zsw>OmF af-�Ov v~izucan o u � F-..,,..m �' ._7 do4 G Wv1H-.?MQZJ 3argCU0 OJNOX ,. SZ 111 F-V,.J to .. .EO�--n K�I--O�OmO f3 H4H¢ '^ 4s ,.-1_, wOwp "".x •---• � F 1#r ' C : ..OwH S�,LL ¢1-mVCJ�S Op OOtnKHOi ,-inU2X =Zv G N�--v`y 1-ACF-LL UOtrNl.i Vlm g�DOLL,Q OH ' ,� ►� � W tib a` a z,N R51 R1, RG1 R11 ei>.~itl � — t'+ P P 'A :tp uY +i3 ♦li qy h. � � m 03 iii m > . P............ � _ U C U F m V un m .n ds +raw+» .•. zG�4� m > z '� f tttp Qv N N N 1! X IOC ry m m c.� ar m rm w m s71 Via'3 ._ ' ,.e vf � ,. .' m e•� m @fid: m as Ov �FUF I�4 Q1 E z 3 m .l �l4 ilw n.: �) t[ �� i : t#tJr �• a y 1 ....z....a Fb #GY6 Cal tV -m G3lsart led a`icp ' c :� 1 P€ .e, O � iPil.'� aL ap e�Li=� +F . Wi...�.•rmi.it�f �, W.arh S , » { x ;{ miC JYOw (SY m.m mar mmmm• z m m+-+ f w na i- +�. � EJ �} 3r 3_. ,.,.. � ��✓+� rti ,vatm of ..N;�33$ ..ua i� 1P�1�aa � p2y� 3 3 w a✓� NM Z p'� � �� Q «� (C � i � C _€ a. LN N..✓ %t^ C'i() € V nv armor ✓'.. amo ren a ✓` n f w atgE F O W ¢w O > > w O V J N QfN-t-t 1- ¢ hVii rr:= w}m wZ V.>J a>p Vl O jO V 2F ZM'-QCI. CJC e-i NwON G`• I� OZ bwMawp Ol•Jwb _ WNOjM QVw l�S V12¢ K F .-Y wus a <zKNt�wx x i IL H1� s-cu. H rzi O �tZ-a�wpFnw SZI�i �wSw 3 3'P i `i ,� e-":: i� S o a z i - �--'�m .., ', 77 �C4 F i jom:r�:� w aux z Qlnwwa m°•1ti W wVH I-�G. F-OW pZ�� O l7 f \ ! )(7 E �d � i- 2 b Q�Q. Q.N.b H¢ N�V1M4 OHS•-K' i Os~ r� y J •Jab FS-VIw ZQaI�-� �OV¢w N O v1KW M'fMmr,�l t�m�Ew JWQtrf}b Q2�Zl7 �-47HV� w ¢ � , ( w�.: �r I i K� uzbvP vPoz Hti ¢= y i �! ' N E P aar.. g� bw � ob u vo�vlu rr _w4. b vl tti . � QZV 3� OCVb O_+NOK .r , Fnw In EO vn¢ t-OO�mO "c33 Q'-+c. 'n"' C� " V ������ Z U « r..M OPV 21-2K..�W CZO�UwVV p$Op V1ZrQr- v ¢�-f21--iwawO4 Qw¢Z_i0 OOt-2w �h-ObV .41 C ..bwi-ym�wrc l-mO¢¢2OOOOv,¢i--tOi-eS Ho.V K ww3� HmbE-u..Vb¢'H VNm�I-�OwKw a` @ C7 'S {I RG1 R11 ig Predator Page :',i Single Package R -410A Heat Pump KK Project Name: SOUTHCENTER TEAM RTU Unit Model #: XPO9000OB2B1BAA1A1 Quantity: 1 System: XP09000OB2B1BAA1A1 Low Leak Downftow Econom zer Low Leak Downflow Economizer (shown with optional Power Exhaust) RCIICI UdillipuI (included) Hood (included) Low leak economizers are capable achieving low leakage rates of 3 cfm/sq, ft at 1" of static pressure, meeting or exceeding the following standards: ASHRAE 90.1-2010 ASHRAE 62 AMCA 511 (licensed as Class 1A damper) International Energy Conservation Code (IECC) California Title 24 The outdoor intake opening shall be covered with a rain hood that matches the exterior of the unit. Water eliminator/filters shall be provided. Simultaneous economizer/compressor operation is also possible. Dampers shall fully close on power loss. tod led) �_" �__� w • imor auon is suolec[ to change without notice. Check local codes, Panted 01!2912016 R 7/ R11 unitary aaies loot v i,o: a,u Intonnabon Is subject to change without notice. Check local codes, Printed 01/29/2016 /? $/ /R // �Predator Page: 8 nnSingle Package R -410A Heat Pump Project Name: SOUTHCENTER TEAM RTU Unit Model #: XP090C00621318AAl Ai Quantity: 1 System: XP0900006281 BAAI Al Sound Performance Sound Performance Indoor Sound Power Levels Size ESP Sound Power, dB (10*12) watts Blower Sound Ratings Octave Band Centerline Frequency (Hz) (Tons) Model CFM MG) 63 125 250 500 1000 2000 4000 8000 RPM BHP dB (A) 078 (6.5) ZH/ZR/XP 2600 0.6 812 1.14 74 71 73 73 71 69 65 65 60 090 (7.5) ZH/ZRIXP 3000 0.6 854 1.47 77 74 76 76 74 72 68 68 63 102 (8.5) ZH/ZR/XP 3400 0.6 872 1.65 80 77 79 79 77 75 71 71 66 120 (10) ZH/ZR/XP 4000 0.6 959 2.29 83 80 82 82 80 78 74 74 69 150 (12.5) ZH/ZR/XP 5000 0.6 1132 3.74 87 84 86 86 84 82 78 78 73 1. These values have been accessed using a model of sound propagation from a point source into the hemispheric/free field. The dBA values provided are to be used for reference only. Calculation of dBA values cover matters of system design and the fan manufacture has no way of knowing the details of each system. This constitutes an exception to any specification or guarantee requiring a dBA value of sound data in any other form than sound power level ratings. Outdoor Sound Power Levels ZH/ZR1XP078-150 Size Model Sound Rating Octave Band Centerline Frequency (Hz) (Tons) dS (A) 125 250 500 1000 1 2000 4000 8000 078 ZH 83 88.0 82.5 81.5 78.0 73.0 69.0 62.0 (6.5) 090 (7.5) ZH 83 89.5 83.5 82.0 78.0 72.5 68.0 60.5 102 (8,5) ZH 90 93.5 92.5 88,0 84.5 79.0 45 68.0 120 (10) ZH 90 94,0 92.0 88.5 84.5 80.0 75.5 68.5 150 i ZH 84 Kill 84.5 81,5 77.5 72.0 68.5 61.5 078 (6.5) 62.0 ZR/XP 83 88.0 82.5 81.5 78.0 73.0 69.0 090 (7.5) ZRlXP 83 89.5 83.5 82.0 78.0 72.5 68.0 60.5 102 (8,5) ZR/XP 83 89.0 84.5 81,5 78,0 72.5 68.5 70.5 120 (10) ZRAP 83 89.5 83.5 81.0 78.0 72.0 68.5 70,5 150 ZR/XP 84 90.0 84.5 81.5 77.5 72.0 68.5 61,5 (12.5) 1. Rated in accordance with ARI 270 standard. unitary aaies loot v i,o: a,u Intonnabon Is subject to change without notice. Check local codes, Printed 01/29/2016 /? $/ /R // ayonv- Predator Page: 9 glum Single Package R-41 OA Heat Pump Project Name: SOUTHCENTER TEAM RTU Unit Model #: XP09000OB2BI BAA1A1 Quantity: 1 System: XP090GOOB2BIBAAIA1 SimpiicityTMControl board w/screw connec- tors for T -stat wiring and network connection Terminal block for hi -voltage connection Second Model Nameplate Inside Control Door Dual stage cooling for maximum comfort Compressor #2 Access(High-Eff Compressor) ' Base Rails w/ Fork lift Slots (3 Sides) & Lifting Holes Roof curbs in eight- and fourteen -inch heights, Disconnect location (optional disconnect switch) Filter access F /2" nr d" altar nntinnalilter drier (solid core) f Side entry power DCompressor #1 Access oo and control wiring (High-Eff Compressor) Doorr Latch knockouts Condenser Slide -out motor and blower assembly for easy adjustment and service. Belt -drive blower motor Slide -out drain pain with steel 3/4" NPT, Female Connection nna,y om=� o,y,u inrormauon is suoiecl to change without notice Check local codes. Printed 01/2912016 �� ,/ ,qct Predator Single Package R -410A Heat Pump Page: 10 Project Name: SOUTHCENTER TEAM RTU 1 Unit Model #: XP090C00B2B1BAA1A1 Quantity: 1 System: XP090C00B2B1BAA1A1 ATED DECK UNDER CENSER SECTION DUCT SIZES: Return 19.5 x 29.5 Supply 19.5 x 29.5 ROOF OPENING: 46 Long 30 Wide " Supply and Return Air (Including duct support rails) as shown, are typical for bottom duct applications. For location of horizontal duct applications (On rear of unit), refer to Unit Dimensions details. Unitary Sales Tool 0.5,9,13 1RC0471 Roof Curb Dimensions Information is subject to change without notice, Check local codes Printed n1 mannir h'/ 0/ R// S=Tr PR SHOP SEAFOOD CITY 2226sf rY SEAFOOD CITY (CHOWKING) 2702sf MORf- BEAUTY I 896sf Ln IROS IROS C 0 IX LIS uj Of to L> co x8 x ct, res ry —354 1_15f 48'— 0' PRECISION TIME r 9090 1 50s f 150sf SEAFOOD CITY 2226sf rY SEAFOOD CITY (CHOWKING) 2702sf MORf- BEAUTY I 896sf —o" 23'-0" 1.6`—Q" 20'— M-OBILE MONEY ATM POTATO ATIV12 BOBA CORNER I SMOOTHIES RI) 1"q11 Ln IROS IROS C 0 IX LIS I lYY d k" Of to L> co x8 x ct, res ry —354 1_15f —o" 23'-0" 1.6`—Q" 20'— M-OBILE MONEY ATM POTATO ATIV12 BOBA CORNER I SMOOTHIES RI) 1"q11 ?ERM!i COORD COPY PLAN REVIEW/ROUTING SLIP PERMIT NUMBER: M16-0082 DATE: 05/25/16 PROJECT NAME: MARINERS TEAM SITE ADDRESS: 1220 SOUTHCENTER MALL X Original Plan Submittal Revision # before Permit Issued Response to Correction Letter # Revision # after Permit Issued DEPARTMENTS: Ni�G ��-��-Ili A-rA 4wc- G -1-1p ing Division IN Fire Prevention IN Planning Division Public Works F-1 Structural F-1 Permit Coordinator PRELIMINARY REVIEW: DATE: 05/26/16 Not Applicable El Structural Review Required (no approval/review required) REVIEWER'S INITIALS: APPROVALS OR CORRECTIONS: Approved ❑ Corrections Required ❑ (corrections entered in Reviews) Notation: DATE: DUE DATE: 06/23/16 Approved with Conditions 1K Denied El (ie: Zoning Issues) REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: 12/18/2013 SULLIVAN HEATING & COOLIP- INC Home Espahol Contact Safety & Health Claims & Insurance CA Washington State Department of Labor & Industries SULLIVAN HEATING & COOLING INC Owner or tradesperson Principals SULLIVAN, DANIEL T, PRESIDENT SULLIVAN, JILL M, SECRETARY Doing business as SULLIVAN HEATING & COOLING INC Page I of 2 Search L&I it A -'Z., Videx Help iv v I'm Workplace Rights Trades & Licensing 5373 AUTO CENTER WAY SUITE 205 BREMERTON, WA 98312 360-405-0723 KITSAP County WA UBI No. Business type 601 588 396 Corporation Governing persons DANIEL THOMAS SULLIVAN JILL MARLENE SULLIVAN; License Verify the contractor's active registration / license / certification (depending on trade) and any past violations. Construction Contractor Active. .......................................................... Meets current requirements. License specialties Heating/Vent/Air-Conditioning and Refrig (HVAC/R) License no. SULLIHCO63QT Effective — expiration 11/30/1994-12/27/2016 Bond RLI INSURANCE CO $6,000.00 Bond account no. LSM0021773 Received by L&I Effective date 11/29/2007 11/28/2007 Expiration date Until Canceled Insurance ...................... American Hallmark Ins Co of Te $1,000,000.00 Policy no. 44CL486050 Received by L&I Effective date 11/13/2015 11/29/2014 Expiration date 11/29/2016 Insurance history Savings .............. . No savings accounts during the previous 6 year period. https:Hsecure.Ini.wa.gov/verify/Detail.aspx?UBI=601588396&LIC=SULLIHCO63QT&SAW= 6/6/2016 Page 1 2 S._Y uYL�� R U.r ED FCR: ® Me, --?;arnica! 153 -Plumbing CD,,das Piping City of Tukwila 1!.n1MG DIVISION REVISIONS No changes shall be made to the scope of v,,ork WiftUt prior approval of �.C�';ti•ri�1 Building Division. will require a new plan submittal and may in;.iude additional plan review fees. Fl n ,,&) j Morcx,Ps I is su7bjact to errors and omissions. ion �'ocurnonts door not auAhoriza t vlola"6' n, -' Ealy a dopiod oodo or ordinance. Recc.jpt c; a r u°v I `i iFi Copy and conditi ,;is is acknowledgod: 131 -y. Date: City of -1 BUILDING DIVISION tea: ;� ✓ 1 RECLiVED CITY OF TUKWILA MAY 19 2916 PERMIT CENTER Google earth all$] -REVIE(V�1ED FOR APPROVED JUN 0 3 2016 �s ViV of TukvAla WILDING ®I�/I�I®� RECEIVED CITY OF TUKWILA MAY 1 .9 2016 PERMIT CENTER D