HomeMy WebLinkAboutPermit M16-0086 - MOR BEAUTY - ROOFTOP UNIT CHANGE OUT1387 SOUTHCENTER MALL M16-0086 City of Tukwila Department of Community Development • 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Inspection Request Line: 206-438-9350 Web site: http://www.TukwilaWA.gov MECHANICAL PERMIT Parcel No: 9202470010 Permit Number: M16-0086 Address: 1387 SOUTHCENTER MALL Issue Date: 6/8/2016 Permit Expires On: 12/5/2016 Project Name: MOR BEAUTY Owner: Name: WESTFIELD PROPERTY TAX DEPT Address: PO BOX 130940, CARLSBAD, WA, 92013 Contact Person: Name: TED HANKE Phone: (360) 405-0723 Address: 5373 AUTOCENTER WAY, BREMERTON, WA, 98312 Contractor: Name: SULLIVAN HEATING & COOLING INC Phone: (360) 405-0723 Address: 5373 AUTO CENTER WAY - STE 205, BREMERTON, WA, 98312 License No: SULLIHCO63QT Expiration Date: 12/27/2016 Lender: Name: Address: DESCRIPTION OF WORK: CHANGE OUT ROOFTOP UNIT. REDO GAS LINE Valuation of Work: $5,000.00 Fees Collected: $258.96 Type of Work: REPLACEMENT Electrical Service Provided by: PUGEST SOUND ENERGY Fuel type: GAS Water District: TUKWILA Sewer District: TUKWILA Current Codes adopted by the City of Tukwila: International Building Code Edition: 2012 National Electrical Code: 2014 International Residential Code Edition: 2012 WA Cities Electrical Code: 2014 International Mechanical Code Edition: 2012 WAC 296-46B: 2014 Uniform Plumbing Code Edition: 2012 WA State Energy Code: 2012 International Fuel Gas Code: 2012 Permit Center Authorized Signature: "16 Date: D I hearby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this development permit and agree tq/the conditions attached to this permit. Signature: Print Nam Date: This permit shall become null and void if the work is not commenced within 180 days for the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. f1� 1►5iit�I�I►11�iL�I`��l 1: Work shall be installed in accordance with the approved construction documents, and any changes made during construction that are not in accordance with the approved construction documents shall be resubmitted for approval. 2: All permits, inspection record card and approved construction documents shall be kept at the site of work and shall be open to inspection by the Building Inspector until final inspection approval is granted. 3: Readily accessible access to roof mounted equipment is required. 4: All construction shall be done in conformance with the Washington State Building Code and the Washington State Energy Code. 5: Remove all demolition rubble and loose miscellaneous material from lot or parcel of ground, properly cap the sanitary sewer connections, and properly fill or otherwise protect all basements, cellars, septic tanks, wells, and other excavations. Final inspection approval will be determined by the building inspector based on satisfactory completion of this requirement. 6: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206-431-3670). 7: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center. 8: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. 9: `MECHANICAL PERMIT CONDITIONS' 10: All mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center (206/431-3670). 11: All permits, inspection record card and approved construction documents shall be kept at the site of work and shall be open to inspection by the Building Inspector until final inspection approval is granted. 12: Manufacturers installation instructions shall be available on the job site at the time of inspection. PERMIT INSPECTIONS REQUIRED Permit Inspection Line: (206) 438-9350 0703 MECH EQUIP EFF 1800 MECHANICAL FINAL 0609 PIPE/DUCT INSULATION 0705 REFRIGERATION EQUIP 0701 ROUGH -IN MECHANICAL CITY OF TUKW, Community Development Department • Permit Centel -6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://www.Tukwi]aNVA.gov SITE LOCATION Site Address: ) 3 Tenant Name Mechanical Permit No. — 00 Project No. Date Application Accepted: Date Application Expires: (For g1fice use only) MECHANICAL PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. **please print** PROPERTY OWNER Name: e ' Address: DO City State: Zip: CONTACT PERSON — person receiving all project communication Na► Address: City: Sate: Zip: Phone:.v Fax- , Email: King Co Assessor's Tax No.: Suite Number: Floor: New Tenant: .....Yes ❑..No MECHANICAL CONTRACTOR INFORMATION Company NameSu .......... ❑ Replacement ........ ❑ "J/ 11 i Address .......... Replacement .......0� mi tj welN) City State: ►p;�g�% Phone:O D 07-73 Fax: Conti Reg No.: ,• /' Ge (0 g ate: / J Tukwila Business License No.: Valuation of project (contractor's bid price): $ J ")OQ e Describe the scope of work in detail: 4"e, © 4� g0c +P (An' + (� 0(D Gas Use: Residential: New .......... ❑ Replacement ........ ❑ Commercial: New .......... Replacement .......0� Fuel Type: Electric..... ❑ Gas ....." Other: - l I %Applications\Forms-Applications On Line\2016 ApplicationsWechanical Permit Application Revised 1-4-16.doex Re%iacd: January 2016 Page 1 of 2 hh 01 Indicate type of mechanical work being installed and the quantity below: Unit Type Qty Furnace <100k btu Residential, Nighttime Furnace >100k btu Industrial Floor furnace 55 dB(A) Suspended/wall/floor mounted heater 57 dB(A) Appliance vent Commercial Repair or addition to heat/refrig/cooling system 47 dB(A) Air handling unit <I0,000 cfm 65 dB(A) Unit Type Qty Air handling unit >I0,000 cfm Evaporator cooler Residential, Nighttime Ventilation fan connected to single duct Industrial Ventilation system 55 dB(A) Hood and duct 57 dB(A) Incinerator — domestic Commercial Incinerator — comm/industrial 47 dB(A) Unit Type Qty Fire damper Residential, Nighttime Diffuser Industrial Thermostat 55 dB(A) Wood/gas stove 57 dB(A) Emergency generator Commercial Other mechanical equipment 47 dB(A) 60 dB(A) 65 dB(A) Boiler/Compressor Qty 0-3 lip/ 100,000 btu 3-15 h /500,000 btu 15-30 hp/1,000,000 btu 30-50 hp/1,750,000 btu 50+ h /1,750,000 but Noise: Mechanical units need to be in compliance with the Tukwila Noise Code. Maximum permissible sound levels are based on from where the sound is created and where the sound is heard. Additionally, if sound can be heard from within a house at night in a residential zone it may not be allowed. For more details, see TMC 8.22 District of Sound Producing Source District of Receiving Property Residential, Daytime* Residential, Nighttime Commercial Industrial Residential 55 dB(A) 45 dB(A) 57 dB(A) 60 dB(A) Commercial 57 dB(A) 47 dB(A) 60 dB(A) 65 dB(A) Industrial 60 dB(A) 50 dB(A) 65 dB(A) 70 dB(A) *Daytime means /AM -t OrM, Monday through Friday and 8AM-IOPM, Saturday, Sunday and State -recognized holidays. A few sounds are exempt from the noise code, including: Warning devices; Construction and property maintenance during the daytime hours (lam-IOpm); Testing of backup generators during the day. PERMIT APPLICATION NOTES - Value of construction — in all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the permit center to comply with current fee schedules. Expiration of plan review — applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The building official may grant one extension of time for additional periods not to exceed 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDII\ Signature: Print Name: �� ,� 1 IJ4 04f% Mailing Address: -Id? dQk � nS r -a h �e iz e. to r I I lAA pp l ications\Forms-Applications On Linc\2016 Applications\Mechanical Permit Applical ion Revised 1-4-I6.docx Revised: January 2016 blt Date: $'/a j 6 Day Telephone: 3 60 - Vas ' 0,707 City Zip Page 2 of 2 DESCRIPTIONS PermitTRAK ACCOUNT QUANTITY PAID $258.96 M16-0086 Address: 1387 SOUTHCENTER MALL Apn: 9202470010 $258.96 MECHANICAL $249.00 PERMIT ISSUANCE BASE FEE R000.322.100.00.00 0.00 $32.50 PERMIT FEE 8000.322.100.00.00 0.00 $166.70 PLAN CHECK FEE R000.322.102.00.00 0.00 $49.80 TECHNOLOGY FEE $9.96 TECHNOLOGY FEE TOTAL FEES PAID BY RECEIPT: R8569 R000.322.900.04.00 0.00 $9.96 $258.96 Date Paid: Wednesday, May 25, 2016 Paid By: THEODORE HANKE Pay Method: CREDIT CARD 028309 Printed: Wednesday, May 25, 2016 1:16 PM 1 of 1 ?" SYSTEMS SULLIVAN HEATING & COOLING INC Page 1 of 2 f-- , Home Espanol t:OntilCt Search L&I A -Z Index Help My L&I Safety & Health Claims & Insurance Workplace Rights Trades & Licensing Washington State Department of Labor & Industries SULLIVAN HEATING & COOLING INC Owner or tradesperson Principals SULLIVAN, DANIEL T, PRESIDENT SULLIVAN, JILL M, SECRETARY Doing business as SULLIVAN HEATING & COOLING INC 5373 AUTO CENTER WAY SUITE 205 BREMERTON, WA 98312 360-405-0723 KITSAP County WA UBI No. Business type 601 588 396 Corporation Governing persons DANIEL THOMAS SULLIVAN JILL MARLENE SULLIVAN; License Verify the contractor's active registration / license / certification (depending on trade) and any past violations. Construction Contractor Active. ...................................................... . Meets current requirements. License specialties Heating/Vent/Air-Conditioning and Refrig (HVAC/R) License no. SULLIHCO63QT Effective — expiration 11/30/1994-12/2712016 Bond RLI INSURANCE CO $6,000.00 Bond account no. LSM0021773 Received by L&I Effective date 11/29/2007 11/28/2007 Expiration date Until Canceled Insurance American Hallmark Ins Co of Te $1,000,000.00 Policy no. 44CL486050 Received by L&I Effective date 11/1312015 11129/2014 Expiration date 11/29/2016 Insurance history Savings No savings accounts during the previous 6 year period. https:Hsecure.Ini.wa.gov/verify/Detail.aspx?UBI=601588396&LIC=SULLIHCO63QT&SAW= 6/3/2016 INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request line (206) 438-9350 KApproved per applicable codes. t,J Corrections required prior to approval. COMMENTS: Inspector: Dater REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. 31 Small Sunline L543 Page:3 Y- 0 R, K, Single Package R -410A Air Conditioner Project Name: BROW ARC -SO. CENTER -REV -1 Unit Model #: ZF036NO8N2AAA2 Quantity: 1 Tag #: 1 IN STOCK -TODAY System: ZF036NO8N2AAA2 pooling verrormance Total capacity 37.5 MBH Sensible capacity 27.1 MBH Refrigerant type R-41 OA Seasonal Efficiency (at ARI) 13.00 SEER Efficiency (at ARI) 11.00 EER Ambient DB temp. 95.0 °F Entering DB temp. 80.0 °F Entering WB temp. 67.0 °F Leaving DB temp. 59.1 °F Leaving WB temp. 57.1 °F Power. input (v✓/o blower) 2.79 kW Sound power 81 dB(A) Gas Heating Performance Entering DB temp. 60 °F Heating output capacity (Max) 79 MBH Supply air 1200 CFM Heating input capacity (Max) 100 MBH Leaving DB temp. 121.0 °F Air temp. rise 61.0 °F SSE 80.8 % Stages 1 Supply Air Blower Performance Supply air 1200 CFM Ext. static pressure 0.6 IWG Blower speed 881 RPM Max BHP of Motor (including service factor) 1.73 HP Duct location Bottom Motor rating 1.50 HP Actual required BHP 0.59 HP Power input 0.55 kW Elevation 0 ft. Drive type BELT Electrical Data Power supply 230-3-60 Unit min circuit ampacity 18.9 Amps Unit max over -current protection 25 Amps Dimensions & Weight Hgt 33 in. Len 83 in. Wth 4541'., Weight with factory installed options 538 lbs': Clearances Right 24 in. Front 32 in. Back 12 in. Ton 72 in Rottnm n In I off on Ir Note: Please refer to the tech guide for listed maximum static pressures l07^ nc RECEIVED CITY OF TUK% MAY 2 5 2016 3 Ton • York Units are Manufactured at an ISO 9001 Registered Facility and Each Rooftop is Completely Computer -Run Tested Prior to Shipment. Unit Features • Unit Cabinet Constructed of Powder Painted Steel, Certified At 1000 Hours Salt Spray Test (ASTM B-117 Standards) • Through -the -Curb and Through -The -Base Utility Connections • Either Supply and/or Return can be Field Converted from Vertical to Horizontal Configuration without Cutting Panels. • Full Perimeter Base Rails with Built in Rigging Capabilities • Galvanized Steel Drain Pan • Reciprocating Compressor • Single Stage Cooling • Solid Core Liquid Line Filter Driers • Microchannel Condenser Coil • 79 MBH Output Aluminized Steel, Single Stage Gas Nominal Heat • 1.5 HP Standard Static Belt Drive Blower • Unit Ships with 1" Throwaway Filters with a Standard Filter Rack That Will Accept up to 2" Filters • Replacement Filters: 2 - (15" x 20" x 1" or 2") and 1 - (14" x 25" x 1" or 2"). Unit accepts 1" or 2" wide filters. • Single Point Power Connection • Short Circuit Current: 5kA RMS Symmetrical Standard Unit Controller: Simplicity Control Board • An Integrated Low -Ambient Control, Anti -Short Cycle Protection, Lead -Lag, Fan On and Fan off Delays, Low Voltage Protection, On -Board Diagnostic E.'`' LAIC cnp a Fault Code Display. Allows all units to operate in the cooling mode down Yv WED FOR to °F outdoor ambient without additional components or intervention. CODE COMPLIANCe ety Monitoring - Monitors the High and Low -Pressure Switches, the APPROVED on zestats, the Gas Valve, if Applicable, and the Temperature Limit Switch on as and Electric Heat Units. The Unit Control Board will Alarm on Ignition MAY 2 2016 Fa ures, Safety Lockouts and Repeated Limit Switch Trips. Wa anty • O e (1) Year Warranty on the Complete Unit • O e (1) Year Warranty - Compressors City of Tukwila • T (10) Year Warranty - Aluminized Steel Tubular Heat Exchangers ILDING DIVISION PERMIT CENTER 110-'L Unitary Sales Tool 0.5.9.0 Information is subject to change without notice. Check local codes. Printed 05/23/2016 Weights Table W 1 — Maximum Unit And Comer Weights (Lbs) And Center Of Gravity Dimensions (in.) Unit Maximum Weights (Lbs)' Corner Weights (Lbs)' Center of Gravity (In.) Tons Model No. Shipping Net A B C D Length Width YS0036A X72 480 151 124 96 109 32 YHCO36A �' � � 497 158 128 101 110 32 YSCO48A \ 597 J 505 159 130 108 109 33 YHC048A 631 539 166 133 114 126 32 5 Note : YSCO60A 614 522 169 134 105 114 32 18 — YHC060A 666 574 179 140 119 136 32 20 6 YSC072A 878 735 249 193 132 161 39 21 YHCO72A 915 772 249 198 141 184 39 22 CENTER YSCO90A 963 820 273 208 146 193 38 22 71/2 YSCO92A 965 822 277 222 147 175 40 21 YHC092A 1066 923 306 243 165 210 39 22 81/2 YSC102A 1042 899 297 243 165 194 40 21 YHC102A 1100 957 310 252 175 220 40 22 10 YSC120A 1063 958 317 261 177 202 41 21 YHC120A 1203 1060 342 277 197 245 40 2T— 2 Notes: 1. Corner weights are given for information only. 2. Weights are approximate. CENTER OF GRAVITY l �— LENGTH — A CEF(G1; �r���\V JWIDTH� CENTER OF GRAVITY REVIEWED FOR CODE COMPLIANCE APPROVED MAY 2 7 2016 City of Tukwila BUILDING DIVISION Table W2 — Factory -installed Options Net Weights (Lbs)' z Accessory 3-57ons Net Weight 6-101ons Economizer 26 36 Barometric Relief 7 10 Powered Exhaust — 80 Motorized Outside Air Damper 20 30 Manual Outside Air Damper 16 26 Roof Curb 70 115 Oversized Motor 5 8 Belt Drive Motor 31 — Smoke Detector, Return 7 7 RECEIVED CITY OF TUKWILA Smoke Detector, Supply Coll Guards Hinged Doors 5 12 10 5 20 12 Powered Convenience Outlet 38 38 MAY2 5 2016 Through the Base Electrical Through the Base Gas 8 5 13 5 Unit Mounted Circuit Breaker 5 5 Unit Mounted Disconnect 5 5 NovarControPERMIT 8 8 CENTER Dehumidification Dehumidification (Hot Gas Reheat) Coil 15 25 94 Notes: i.Weights for options not listed are < 5lbs. 2.Net weight should be added to unit weight when ordering factory -installed accessories, �%-0086 RT-PRC006-EN i PERMIT COORD COPY PLAN REVIEW/ROUTING SLIP PERMIT NUMBER: M16-0086 DATE: 05/25/16 PROJECT NAME: MOR BEAUTY SITE ADDRESS: 1387 SOUTHCENTER MALL X Original Plan Submittal Revision # before Permit Issued Response to Correction Letter # Revision # after Permit Issued DEPARTMENTS: o Ail✓ 5-U-10 Building Division Public Works ❑ PRELIMINARY REVIEW: Not Applicable ❑ (no approval/review required) REVIEWER'S INITIALS: APPROVALS OR CORRECTIONS: Approved ❑ Corrections Required ❑ (corrections entered in Reviews) Notation: REVIEWER'S INITIALS: ' -t� Firevention Structural ❑ Planning Division ❑ Permit Coordinator 99 DATE: 05/26/16 Structural Review Required ❑ DATE: DUE DATE: 06/23/16 Approved with Conditions Denied ❑ (ie: Zoning Issues) DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: 12/18/2013 SHEET INDEX ARCHITECTURAL G-0.0 COVER SHEET AD -2.0 DEMOLITION FLOOR PLAN + DEMOLITION REFLECTED CEILING PLAN A-2.0 FLOOR PLAN / REFLECTED CEILING PLAN/ DETAILS A-5.0 STOREFRONT ELEVATION Landlord W- Tenant Entra.nce Alteration FILE COPY Permit Nos --JAA- I -� -, VO� MOR BeautTenant a ce C-2 1 Play review a0prov l is subject to errors and cm, !A— iop s. y ;approval of construction documents d®as not au'h0fi7e e vlotatlon Of fflY 8010p' ed cod or ordinance. Roceipft 1387 SOUTHCENTER MALL--- - , of approvad Field Co and coditions is acknowledgod: REVISIONS TUKWILA, WA 981 8 No changes shall be made to the scope S ; of work without prior approval of Tukwila Building Division. Date: NOTE: Revisions will require a new plan submittal PERMIT SET - 0 3.22.2 016 and may include additional plan review fees. City of ` ukiwila SEPARATE PERMITS / DESIGN BUILD FIRE ALARM SYSTEM SPRINKLER SYSTEM ELECTRICAL PROJECT DESCRIPTION SCOPE OF WORK INCLUDES THE DEMOLITION OF AN EXISTING FASCIA STRIP WITHIN A MALL CONCOURSE. ONE EXISTING NEUTRAL PIER WILL BE EXTENDED AND A NEW BULKHEAD AT THE FRONT WILL BE INSTALLED IN THE EXISTING TENANT SPACE. THERE IS NO STRUCTURAL WORK WITHIN THIS SCOPE. PROJECT TEAM ARCHITECT PROPERTY MANAGEMENT JJW ARCHITECTS AND PLANNERS WESTFIELD SOUTHCENTER 5628 AIRPORT WAY SOUTH, SUITE 112 2800 SOUTHCENTER MALL SEATTLE, WA 98108 TUKWILA, WA 98188 P: 206.420.2242 P: 206.714.3485 F: 206.260.9595 ATTN: WAYNE E. JOHNSON ATTN: JEFF WASSERMAN E: WJOHNSON@US.WESTFIELD.COM E: JWASSERMAN@JJWARCH.COM SYMBOLS J14 (ARCHITECTURAL) - (ALL SYMBOLS ARE NOT NECESSARILY USED) ROOM NUMBER DOOR NUMBER WINDOW TYPES KEY TO WALL FINISH SCHEDULE KEY TO FLOOR FINISH SCHEDULE CEILING FINISH CEILING HEIGHT A 11'-11" KEY TO CEILING FINISH SCHEDULE 0— KEY TO WALL TYPES (S1 ) COLUMN CENTERLINE 1 0 REFER TO DETAIL NUMB SEE 2/A-1 LV-- SHEET NUMB SECTION MARK ENLARGED PLAN/ DETAIL REFERENCE ELEVATION KEY REVISION CLOUD WITH REVISION DELTA TAG HOLD CLOUD NOT TO SCALE CODE INFORMATION Level 1 7n AI I nI ('-" It. ndover Park W. Q Family m Parking LL VICINITY MAP TUKWILA URBAN CENTER (TUC) APPLICABLE CODES 2012 INTERNATIONAL BUILDING CODE (IBC) + WAC 51-50' + ORD. 6113, CHAP. 23.05 & 23.10" + ICC Al 17.1-2009 ACCESSIBLE AND USABLE BUILDINGS AND FACILITIES 2012 INTERNATIONAL RESIDENTIAL CODE (IRC) + WAC 51-51 + ORD. 6113, CHAP. 23.12" 2012 WASHINGTON STATE ENERGY CODE (WSEC) + WAC 51-11' 2012 INTERNATIONAL FIRE CODE (IFC) + WAC51-54A' +ORD. 6114, CHAP. 23.11"' CONSTRUCTION TYPE 2008 NATIONAL ELECTRICAL CODE (NEC) (NEPA 70) + PART 1 AND PART 3, 2009 WASHINGTON CITIES ELECTRICAL CODE"" 2012 INTERNATIONAL MECHANICAL CODE (IMG + WAC 51-52' +ORD. 6113, CHAP. 23.50" 2012 INTERNATIONAL NATIONAL FUEL AND GAS CODE (IFGC) + WAC 51-52-21000• 2012 UNIFORM PLUMBING CODE (UPC) + WAC 51-56' + ORD. 6113, CHAP. 23.60•• EXISTING BUILDING - TYPE IIB CONSTRUCTION FULLY SPRINKLED (PER NAFPA 13) NEW CONSTRUCTION - TYPE IIB CONSTRUCTION REVIEWED FOR CODE COMPLIARICE OCCUPANCY CLASSIFICATION APPROVEID MERCANTILE: (NO CHANGE TO EXISTING) MAY 2 7 2016 AREA OF WORK = 460 SF (NO CHANGE TO EXISTING) PARKING CircfTukwila NO CHANGE TO EXISTING BUILDING DIVISION NOTE ao THIS SCOPE OF WORK IS FOR COSMETIC WORK ONLY AND DOES NOT AFFECT OCCUPANCY COUNTS OR EXITING REQUIREMENTS. SEPARATE PERMIT REQUIRED FOR: ❑ Mechanical E'Iectricaf L.ojPlumbing C Gas Piping City of Tukwila lull -DING DIVISION OUTHCENTER IALL )URCE: GOOGLE EARTH, 2015 RECEIVED CITY OF TUKWILA MAY 2 5 2016 PERMIT CENTER: NOT TO SCALEPLAN ORTH N EARTH GRAVEL/BALLAST r SAND m CONCRETE L PRECAST CONCRETE ® STEEL Q GYM FLOOR U ® WOOD (CONTINUOUS BLOCKING) 07 00ca WOOD (NON -CONTINUOS BLOCKING) ® WOOD (TRIM/FINISH) �ooLo �rn� GLASS ® STONE O SHINGLES 2 ca. N 0 CONCRETE MASONRY UNIT QQ ��co BRICK VENEER CO oo N N N METAL STUDS U PRECAST (IN PLAN) �Li-,;-:4) STEEL (LARGE SCALE) J PLYWOOD (LARGE SCALE) GYPSUM WALL BOARD (LARGE SCALE) BATT INSULATION RIGID INSULATION PROTECTION BOARD Z CARPET (LARGE SCALE) ACOUSTICAL TILE (LARGE SCALE) TILE (LARGE SCALE) NOT TO SCALE CODE INFORMATION Level 1 7n AI I nI ('-" It. ndover Park W. Q Family m Parking LL VICINITY MAP TUKWILA URBAN CENTER (TUC) APPLICABLE CODES 2012 INTERNATIONAL BUILDING CODE (IBC) + WAC 51-50' + ORD. 6113, CHAP. 23.05 & 23.10" + ICC Al 17.1-2009 ACCESSIBLE AND USABLE BUILDINGS AND FACILITIES 2012 INTERNATIONAL RESIDENTIAL CODE (IRC) + WAC 51-51 + ORD. 6113, CHAP. 23.12" 2012 WASHINGTON STATE ENERGY CODE (WSEC) + WAC 51-11' 2012 INTERNATIONAL FIRE CODE (IFC) + WAC51-54A' +ORD. 6114, CHAP. 23.11"' CONSTRUCTION TYPE 2008 NATIONAL ELECTRICAL CODE (NEC) (NEPA 70) + PART 1 AND PART 3, 2009 WASHINGTON CITIES ELECTRICAL CODE"" 2012 INTERNATIONAL MECHANICAL CODE (IMG + WAC 51-52' +ORD. 6113, CHAP. 23.50" 2012 INTERNATIONAL NATIONAL FUEL AND GAS CODE (IFGC) + WAC 51-52-21000• 2012 UNIFORM PLUMBING CODE (UPC) + WAC 51-56' + ORD. 6113, CHAP. 23.60•• EXISTING BUILDING - TYPE IIB CONSTRUCTION FULLY SPRINKLED (PER NAFPA 13) NEW CONSTRUCTION - TYPE IIB CONSTRUCTION REVIEWED FOR CODE COMPLIARICE OCCUPANCY CLASSIFICATION APPROVEID MERCANTILE: (NO CHANGE TO EXISTING) MAY 2 7 2016 AREA OF WORK = 460 SF (NO CHANGE TO EXISTING) PARKING CircfTukwila NO CHANGE TO EXISTING BUILDING DIVISION NOTE ao THIS SCOPE OF WORK IS FOR COSMETIC WORK ONLY AND DOES NOT AFFECT OCCUPANCY COUNTS OR EXITING REQUIREMENTS. SEPARATE PERMIT REQUIRED FOR: ❑ Mechanical E'Iectricaf L.ojPlumbing C Gas Piping City of Tukwila lull -DING DIVISION OUTHCENTER IALL )URCE: GOOGLE EARTH, 2015 RECEIVED CITY OF TUKWILA MAY 2 5 2016 PERMIT CENTER: NOT TO SCALEPLAN ORTH N r m L E U Q U 0- O N 07 00ca ?' m Z �ooLo �rn� W 1✓ Q N 0 E. 2 ca. N 0 (U QQ ��co CO oo N N N . U �Li-,;-:4) � i- 0 - Q W m Z W .-. OWN O U � � J UW OC) Z Z 00 9wo, LUQ Z= O w1 --Q 0 Z O J Z Q U) <WM� _I E— T— F -- DATE I ISSUE 03.22.2016 IREVIEWSET G-0.0 2016-05-00