Loading...
HomeMy WebLinkAboutPermit M16-0101 - MORRIS RESIDENCE - GAS FURNACE REPLACEMENT AND HEAT PUMPMORRIS RESIDENCE 4412 S 150 ST M16-0101 City of Tukwila • Department of Community Development • 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Inspection Request Line: 206-438-9350 Web site: http://www.TukwilaWA.gov MECHANICAL OTC PERMIT Parcel No: 0042000074 Address: 4412 S 150TH ST Project Name: MORRIS RESIDENCE Owner: Name: MORRIS EDNA M Address: 4412 S 150TH ST, TUKWILA, WA, 98168 Contact Person: Name: ETHAN ONAT Address: 3909 196TH ST SW, EDMONDS, WA, International Residential Code Edition: 98036 Contractor: 2014 Name: WASHINGTON ENERGY SVCS CO LLC Address: 3909 196TH ST SW, LYNNWOOD, WA, Uniform Plumbing Code Edition: 98036 License No: WASHIES851NS Lender: 2012 Name: Address: , , , DESCRIPTION OF WORK: Permit Number: M16-0101 Issue Date: 6/15/2016 Permit Expires On: 12/12/2016 Phone: (206) 378-6927 Phone: Expiration Date: 9/7/2017 REPLACING GAS FURNACE LIKE FOR LIKE - ADDING HEAT PUMP. Valuation of Work: $10,872.00 Fees Collected: $272.48 Type of Work: REPLACEMENT Fuel type: GAS Electrical Service Provided by: SEATTLE CITY LIGHT Water District: 125 Sewer District: VALLEY VIEW Current Codes adopted by the City of Tukwila: International Building Code Edition: 2012 National Electrical Code: 2014 International Residential Code Edition: 2012 WA Cities Electrical Code: 2014 International Mechanical Code Edition: 2012 WAC 296-468: 2014 Uniform Plumbing Code Edition: 2012 WA State Energy Code: 2012 International Fuel Gas Code: 2012 Permit Center Authorized Signature: Nm A LL-- Date: `� I hearby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this development permit and agree to the conditions attached to this permit. Signatu Print N are: Date: S ` / me:e,Z This permit shall become null and void if the work is not commenced within 180 days for the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. PERMIT CONDITIONS: 1: `MECHANICAL PERMIT CONDITIONS' 2: All mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center (206/431-3670). 3: All permits, inspection record card and approved construction documents shall be kept at the site of work and shall be open to inspection by the Building Inspector until final inspection approval is granted. 4: Manufacturers installation instructions shall be available on the job site at the time of inspection. 5: Except for direct -vent appliances that obtain all combustion air directly from the outdoors; fuel -fired appliances shall not be located in, or obtain combustion air from, any of the following rooms or spaces: Sleeping rooms, bathrooms, toilet rooms, storage closets, surgical rooms. 6: Equipment and appliances having an ignition source and located in hazardous locations and public garages, PRIVATE GARAGES, repair garages, automotive motor -fuel dispensing facilities and parking garages shall be elevated such that the source of ignition is not less than 18 inches above the floor surface on which the equipment or appliance rests. 7: Type 1 Hoods, the required grease duct leakage test and Ilight test shall be performed by a special inspection and testing agency in accordance with I.M.C. Chapter 5. PERMIT INSPECTIONS REQUIRED Permit Inspection Line: (206) 438-9350 1800 MECHANICAL FINAL 0701 ROUGH -IN MECHANICAL CITY OF TUKWl-,-_ _ Comm niity Development Department Permit Center • ' 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://www.Tukwi]aWA.gov Mechanical Permit No. U 10 1 Project No. Date Application Accepted: Date Application Expires:' use MECHANICAL PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. "please print" SITE LOCATION King Co Assessor's Tax No.: 0042000074 Site Address: 4412 S 150th St Tukwila WA 98188 Suite Number: Floor: Tenant Name: Edna Morris New Tenant: ❑ .....Yes ®..No PROPERTY OWNER Name: Edna Morris Address: 4412 S 150th St City: Tukwila State: WA Zip: 98188 CONTACT PERSON — person receiving all project communication Name: Ethan Onat Address: 3909 196th St SW City: Lynnwood State: WA Zip: 98036 Phone: (206) 378-6927 Fax: E►nail: eonat@washingtonenergy.com Valuation of project (contractor's bid price): $ 10,872 MECHANICAL CONTRACTOR INFORMATION Company Name: Washington Energy Services Address: 3909 196th St SW City: Lynnwood State: WA Zip: 98036 Phone: (206) 378-6927 Fax: Contr Reg No.: WASHIES851NS Exp Date: 09/07/2017 Tukwila Business License No.: BUS -0996555 Describe the scope of work in detail: Replacing gas furnace like for like; adding heat pump Use: Residential: New .......... ® Replacement ........ Commercial: New .......... ❑ Replacement ........ ❑ Fuel Type: Electric..... ® Gas ....... 0 Other:_ I \ApplicaiionsUorms-Applicai ions On 1-ineL016 Applications\Uechanical Permit Application Revised 1-4-16.doc\ Revised. Januan.2016 11a2e I of t bh Indicate type of mechanical work being installed and the quantity below: Unit Type Qty Furnace <100k btu 1 Furnace >I 00k btu Industrial Floor furnace 55 dB(A) Suspended/wall/floor mounted heater 57 dB(A) Appliance vent Commercial Repair or addition to heat/refrig/cooling system 47 dB(A) Air handling unit <I0,000 cfm 1 .;s Unit Type w Qty, Air handling unit ->I 0,000 cfm Residential, Nighttime Evaporator cooler Industrial Ventilation fan connected to single duct 55 dB(A) Ventilation system 57 dB(A) Hood and duct Commercial Incinerator — domestic 47 dB(A) — Incinerator _T1 comm/industrial 65 dB(A) Unit Type ' - Qty Fire damper Residential, Nighttime Diffuser Industrial Thermostat 55 dB(A) Wood/gas stove 57 dB(A) Emergency generator Commercial Other mechanical equipment 47 dB(A) 60 dB(A) 65 dB(A) A. Boiler/Compressor Qty 0-3 hp/100,000 btu 3-15 h /500,000 btu 15-30 hp/1,000,000 btu 30-50 hp/1,750,000 btu 50+ h /1,750,000 btu Noise: Mechanical units need to be in compliance with the Tukwila Noise Code. Maximum permissible sound levels are based on from where the sound is created and where the sound is heard. Additionally, if sound can be heard from within a house at night in a residential zone it may not be allowed. For more details, see TMC 8.22 District of Sound Producing Source District of Receiving Property Residential, Daytime* Residential, Nighttime Commercial Industrial Residential 55 dB(A) 45 dB(A) 57 dB(A) 60 dB(A) Commercial 57 dB(A) 47 dB(A) 60 dB(A) 65 dB(A) Industrial 60 dB(A) 50 dB(A) 65 dB(A) 70 dB(A) *Daytime means 7AM-I OPM, Monday through Friday and 8AM-IOPM, Saturday, Sunday and State -recognized holidays. A few sounds are exempt from the noise code, including: Warning devices-, Construction and property maintenance during the daytime hours (lam -I Opm); Testing of backup generators during the day. PERMIT APPLICATION NOTES s ""O"w„ � i yc •. Value of construction — in all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the permit center to comply with current fee schedules. Expiration of plan review — applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The building official may grant one extension of time for additional periods not to exceed 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND 1 AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER OR AKrHORIZED AGENT: Print Name: Ethan Date: 06/07/2016 Day Telephone: (206) 378-6927 Mailing Address: 3909 196th St SW Lynnwood WA 98036 City Statc Zip li:\Applications\Forms-Applications On Line\2016 ApplicationAMechanical Permit Application Revised 1-4-16.docs Revised. January 2016 Pate 2 of 2 bh DESCRIPTIONS PermitTRAK • QUANTITY $272.48 M16-0101 Address: 4412 S 150TH ST Apn: 0042000074 $272.48 MECHANICAL $259.50 PERMIT FEE R000.322.100.00.00 0.00 $227.00 PERMIT ISSUANCE BASE FEE R000.322.100.00.00 0.00 $32.50 TECHNOLOGY FEE $12.98 TECHNOLOGY FEE TOTALRECEIPT:R8741 R000.322.900.04.00 0.00 $12.98 $272.48 Date Paid: Wednesday, June 15, 2016 Paid By: WASHINGTON ENERGY SVCS CO LLC Pay Method: CHECK 3297 Printed: Wednesday, lune 15, 2016 11:25 AM 1 of 1 �l !l l �/l._fsysrEMs k INSPECTION RECORD 106`"0 f Retain a copy with permit INSPECTION N0, PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Kw4 k —1-4. + Project: _ C Type of Inspe tion: ` . 'A' Date Called: Special lnstructions:I Date anti.._= a.m. p.m. Requester: Phone No: IInspector: IDate: o/ —2—, f`/6 REINSPECTION FEE REQUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. WASHINGTON ENERGY SVCS C LLC Washington State Department of Labor & Industries Page 1 of 2 Home Isspafiol Contact Search L&1 A -'L Index help My L&I Safety & Health Claims & Insurance Workplace Rights Trades & Licensing WASHINGTON ENERGY SVCS CO LLC Owner or tradesperson 3909196TH STREET SW LYNNWOOD, WA 98036 Principals 206-282-4700 OLSON, CRAIG E, PARTNER/MEMBER SNOHOMISH County OLSON, VERA A, PARTNER/MEMBER NG, YUN-KWAN WINNIE, AGENT Doing business as WASHINGTON ENERGY SVCS CO LLC WA UBI No. Business type 603 522 032 Limited Liability Company Governing persons CRAIG E OLSON LLC FIRST POINT; VERN A OLSON; License Verify the contractor's active registration / license / certification (depending on traded and any past violations. Construction Contractor ......................1...11.1.................... Active. _....._..........._ Meets current requirements. License specialties GENERAL License no. WASHIES851NS Effective — expiration 09/07/2015— 09/07/2017 Bond ................. North American Spec Ins Cc $12,000.00 Bond account no. 2198899 Received by L&I Effective date 08/10/2015 09/07/2015 Expiration date Until Canceled Insurance .............................. United Specialty Insurance Com $1,000,000.00 Policy no. BV01673641 Received by L&I Effective date 04/29/2016 05/01/2016 Expiration date 05/01/2017 Insurance history https:Hsecure.Ini.wa.gov/verify/Detail.aspx?UBI=603522032&LIC=WASHIES851NS&SAW= 6/15/2016 WASHINGTON ENERGY SVCS C1_' 1 LC S.a.....vings .................. No savings accounts during the previous 6 year period. Lawsuits against the bond or savings No lawsuits against the bond or savings accounts during the previous 6 year period. L&I Tax debts ......................................... No L&I tax debts are recorded for this contractor license during the previous 6 year period, but some debts may be recorded by other agencies. License Violations Infraction no. PZETDO0865Satisfied .......................... Issue date RCW/WAC 05/06/2016 18.106.020 Violation city Violation amount LYNNWOOD $250.00 Type of violation PLUMBER INFRACTION Description Contractor employed a person to engage in the trade of plumbing without a current journeyman, specialty or trainee certificate, temporary permit or medical gas endorsement as required. Danny H Padilla Workers' comp Do you know if the business has employees? If so, verify the business is up-to-date on workers' comp premiums. This company has multiple workers' comp accounts. Active accounts L&I Account ID Account is current. 224,000-17 .. ........... I................... Doing business as WENERGY LLC Estimated workers reported Quarter 1 of Year 2016 "Greater than 100 Workers" L&I account representative T2 / SUSAN BETTS (360)902-4828 - Email: BETT235@lni.wa.gov Track this contractor io Workplace safety and health Check for any past safety and health violations found on jobsites this business was responsible for. O Washington Slate Dept. of Labor & Industries. Use of this site is subject to the laws of the state of Washington. Page 2 of 2 https:Hsecure.Ini.wa.gov/verify/Detail.aspx?UBI=603522032&LIC=WASHIES851NS&SAW= 6/15/2016