Loading...
HomeMy WebLinkAboutPermit M16-0102 - HOLSTINE RESIDENCE - GAS FURNACE REPLACEMENT AND A/C UNITHOLSTINE RESIDENCE 4251 S 160 ST M16-0102 City of Tukwila ' Department of Community Development • 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Inspection Request Line: 206-438-9350 Web site: http://www.TukwilaWA.gov MECHANICAL OTC PERMIT Parcel No: 5379800070 Permit Number: M16-0102 Address: 4251 S 160TH ST Issue Date: 6/15/2016 WA Cities Electrical Code: 2014 Permit Expires On: 12/12/2016 Project Name: HOLSTINE RESIDENCE 2014 Owner: 2012 WA State Energy Code: Name: HOLSTINE WILLIAM C+ARDIS L 2012 Address: 4251 S 160TH ST, SEATTLE, WA, 98188 Permit Center Authorized Signature: Contact Person: r Date: Name: SARAH TURNER Phone: (206) 244-1136 Address: 12462 DES MOINES MEMORIAL DR, BURIEN, WA, 98168 Contractor: Name: GLENDALE HEATING & A/C INC Phone: (206) 243-7700 Address: 12462 DES MOINES MEMORIAL DR, SEATTLE, WA, 98168-2266 License No: GLENDHA053Q2 Expiration Date: 11/2/2017 Lender: Name: Address: DESCRIPTION OF WORK: REMOVE EXISTING GAS FURNACE AND REPLACE WITH NEW GAS FURNACE AND ADD AIR CONDITIONER Valuation of Work: $12,098.00 Fees Collected: $293.58 Type of Work: REPLACEMENT Electrical Service Provided by: PUGEST SOUND ENERGY Fuel type: GAS Water District: HIGHLINE Sewer District: VALLEY VIEW Current Codes adopted by the City of Tukwila: International Building Code Edition: 2012 National Electrical Code: 2014 International Residential Code Edition: 2012 WA Cities Electrical Code: 2014 International Mechanical Code Edition: 2012 WAC 296-4613: 2014 Uniform Plumbing Code Edition: 2012 WA State Energy Code: 2012 International Fuel Gas Code: 2012 Permit Center Authorized Signature: r Date: I hearby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this development per 'and agree t e ditions attached to this permit. LL� Signature: Date: J /� Print Name: This permit shall become null and void if the work is not commenced within 180 days for the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. PERMIT CONDITIONS: 1: `MECHANICAL PERMIT CONDITIONS' 2: All mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center (206/431-3670). 3: All permits, inspection record card and approved construction documents shall be kept at the site of work and shall be open to inspection by the Building Inspector until final inspection approval is granted. 4: Manufacturers installation instructions shall be available on the job site at the time of inspection. 5: Except for direct -vent appliances that obtain all combustion air directly from the outdoors; fuel -fired appliances shall not be located in, or obtain combustion air from, any of the following rooms or spaces: Sleeping rooms, bathrooms, toilet rooms, storage closets, surgical rooms. 6: Equipment and appliances having an ignition source and located in hazardous locations and public garages, PRIVATE GARAGES, repair garages, automotive motor -fuel dispensing facilities and parking garages shall be elevated such that the source of ignition is not less than 18 inches above the floor surface on which the equipment or appliance rests. 7: Type 1 Hoods, the required grease duct leakage test and Ilight test shall be performed by a special inspection and testing agency in accordance with I.M.C. Chapter 5. PERMIT INSPECTIONS REQUIRED Permit Inspection Line: (206) 438-9350 1800 MECHANICAL FINAL 0701 ROUGH -IN MECHANICAL CITY OF TUKWILA Community Development Department Permit Center • 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://www.TukwilaWA.gov Mechanical Permit No. Btb—oto� Project No. Date Application Accepted: Date Application Expires: use MECHANICAL PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. **please print** SITE LOCATION King Co Assessor's Tax No.: 5379800070 Site Address: 4251 S 160th St Tukwila WA 98188 Tenant Name: PROPERTY OWNER Name: William Holstine Address: 4251 S 160th St City: Tukwila State: WA Zip: 98188 CONTACT PERSON — person receiving all project communication Name: Glendale Heating and Air Conditioning Address: 12462 Des Moines Memorial Drive City: Burien State: WA Zip: 98168 Phone: (206) 244-11.36 Fax: (206) 243-8344 Email: email@glendaleheating.com Valuation of project (contractor's bid price): $ 12,098 Describe the scope of work in detail: Suite Number: Floor: New Tenant: ❑ .....Yes ❑ ..No MECHANICAL CONTRACTOR INFORMATION Company Name: Glendale Heating and Air Conditionij Address: 12462 Des Moines Memorial Dr City: Burien State: WA Zip: 98168 Phone: (206) 244-1.1.36 Fax: (206) 243-8344 Contr Reg No.: GLENDHA053Q2 Exp Date: 11/02/2017 Tukwila Business License No.: BUS -0993977 Remove existing gas furnace and replace with new gas furnace and add air conditioner Use: Residential: New .......... ❑ Replacement ........ 0 Commercial: New .......... ❑ Replacement ........ ❑ Fuel Type: Electric..... ❑ Gas ....... m Other:_ H:Wpplications\Forms-Applications On Line\2016 AppliwtionsWechanical Perrot Application Revised 14-16.docx Revised: January 2016 Page 1 of 2 bh Indicate type of mechanical work being installed and the quantity below: Unit Type Qty Furnace <I OOk btu ] Furnace >I OOk btu Industrial Floor f imace 55 dB(A) Suspended/wall/floor mounted heater 57 dB(A) Appliance vent Commercial Repair or addition to heat/refrig/cooling system ] Air handling unit <10,000 elm 65 dB(A) Unit Type Qty Air handling unit >I0.000 cfm Residential, Nighttime Evaporator cooler Industrial Ventilation fan connected to single duct 55 dB(A) Ventilation system 57 dB(A) Hood and duct Commercial Incinerator — domestic 47 dB(A) Incinerator — comm/industrial 65 dB(A) Unit Type Qty Fire damper Residential, Nighttime Diffuser Industrial Thermostat 55 dB(A) Wood/gas stove 57 dB(A) Emergency enerator Commercial Other mechanical equipment 47 dB(A) 60 dB(A) 65 dB(A) Boiler/Compressor Qty 0-3 hp/100,000 btu 3-15 h /500,000 btu 15-30 hp/1,000,000 btu 30-50 hp/1,750,000 btu 50+ h /1,750,000 btu Noise: Mechanical units need to be in compliance with the Tukwilalloise Code. Maximum permissible sound levels are based on from where the sound is created and where the sound is heard. Additionally, if sound can be heard from within a house at night in a residential zone it may not be allowed. For more details, see TMC 8.22 District of Sound Producing Source District of Receiving Property Residential, Daytime* Residential, Nighttime Commercial Industrial Residential 55 dB(A) 45 dB(A) 57 dB(A) 60 dB(A) Commercial 57 dB(A) 47 dB(A) 60 dB(A) 65 dB(A) Industrial 60 dB(A) 50 dB(A) 65 dB(A) 70 dB(A) *Daytime means 7AM-IOPM, Monday through Friday and 8AM-I OPM, Saturday, Sunday and State -recognized holidays. A few sounds are exempt from the noise code, including: Warning devices; Construction and property maintenance during the daytime hours (lam -1 Opm); Testing of backup generators during the day. PERMIT APPLICATION NOTES - Value of construction — in all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the permit center to comply with current fee schedules. Expiration of plan review — applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The building official may grant one extension of time for additional periods not to exceed 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING Date: 06/14/2016 Print Name: Sarah Turner Day Telephone: (206) 244-1136 Mailing address: 12462 Des Moines Memorial Drive Burien WA 98168 City State Zip H:\Applications\Forms-Applications On Line\2016 Applications\Mechanical Permit Application Revised 1-4-16.docx Revised: January 2016 Page 2 of 2 bh DESCRIPTIONS PermitTRAK ACCOUNT QUANTITY PAID $356.42 EL16-0548 Address: 4251 S 160TH ST Apn: 5379800070 $62.84 ELECTRICAL $59.85 PERMIT FEE SINGLE FAMILY R000.322.101.00.00 0.00 $59.85 TECHNOLOGY FEE $2.99 TECHNOLOGY FEE R000.322.900.04.00 0.00 $2.99 M16-0102 Address: 4251 S 160TH ST Apn: 5379800070 $293.58 MECHANICAL $279.60 PERMIT FEE R000.322.100.00.00 0.00 $247.10 PERMIT ISSUANCE BASE FEE R000.322.100.00.00 0.00 $32.50 TECHNOLOGY FEE $13.98 TECHNOLOGY FEE TOTAL FEES PAID BY RECEIPT: R8744 R000.322.900.04.00 0.00 $13.98 $356.42 Date Paid: Wednesday, June 15, 2016 Paid By: GLENDALE HEATING & A/C INC Pay Method: CHECK 008111 Printed: Wednesday, June 15, 2016 1:32 PM 1 of 1 rmSYS7EM5 a/INSPECTION RECORD _ O ilRetain a copy with permit INSPE N N0. PERMIT N0. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 06) 431-3670 Permit Inspection Request Line (206) 438-9350 Ko avk -y (�, Proj ct: s he, A� Type of =-i r( 'P'a A rerr b f � � Li 7TSpecial Date Called: Inlstructions:� ItA Date Wante�j / a.m. to —%b p.m. Requester: Phone No: Approved per applicable codes. 11 Corrections required prior to approval. In Iinspector: /� Iuate: //?7 116 f6 I REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. GLENDALE HEATING & A/C INC Home Espanol Contact Safety & Health Claims & Insurance A^ Washington State Department of kj Labor & Industries GLENDALE HEATING & A/C INC Owner or tradesperson Principals HOEFER, GERALD ARTHUR, PRESIDENT FULTON, DAVID CURTIS, SECRETARY ATWOOD, STANLEY, AGENT (End: 06/26/2012) HOEFER, ARTHUR A, TREASURER (End: 09/30/2011) Doing business as GLENDALE HEATING & A/C INC WA UBI No. 600 003167 License Page 1 of 2 Search L&I \-'Z, Index Ifelp My L I Workplace Rights 12462 DES MOINES MEMORIAL DR SEATTLE, WA 98168-2266 206.243-7700 KING County Business type Corporation Governing persons DAVID C FULTON GERALD A HOEFER; Verify the contractor's active registration / license / certification (depending on trade) and any past violations. CContract ................................onstruction..........................................or Active. Meets current requirements. License specialties GENERAL License no. GLENDHA053Q2 Effective — expiration 11/22/1995-11/02/2017 Bond ................. No bond accounts during the previous 6 year period. Insurance ............... _.............. Continental Western Ins Co $1,000,000.00 Policy no. CDP2976203 Received by L&1 Effective date 08/1112015 11/02/2012 Expiration date 11/02/2016 Insurance history Saving.s _.........._..... (in lieu of bond) $12,000.00 Received by L&I Effective date 10/15/2001 10/15/2001 Trades & Licensing -77 https:Hsecure.Ini.wa.gov/verify/Detail.aspx?UBI=600003167&LIC=GLENDHAO53Q2&SAW= 6/15/2016