HomeMy WebLinkAboutPermit M16-0117 - 14520 INTERURBAN BUILDING / VACANT SPACE - ROOFTOP UNIT AND DUCT SYSTEMVACANT EXPENSE 14520 INTERURBAN AVE S M16-0117 City of Tukwila Department of Community Development • 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Inspection Request Line: 206-438-9350 Web site: http://www.TukwilaWA.Rov MECHANICAL PERMIT Parcel No: 3365901630 Permit Number: M16-0117 Address: 14520 INTERURBAN AVE S Issue Date: 8/3/2016 Permit Expires On: 1/30/2017 Project Name: VACANT SPACE Owner: Name: SANFT LOUIE Address: 6120 52ND AVE S, SEATTLE, WA, Lender: Name: Address: DESCRIPTION OF WORK: INSTALL ONE 7.5 TON ROOF TOP UNIT AND DUCT SYSTEM Phone: (425) 754-8759 Phone: (425) 303-0828 `" Expiration Date: 10/1/2017 Valuation of Work: $14,800.00 Fees Collected: $389.62 Type of Work: NEW Electrical Service Provided by: PUGET SOUND ENERGY Fuel type: GAS Water District: TUKWILA Sewer District: TUKWILA SEWER SERVICE Current Codes adopted by the City of Tukwila: International Building Code Edition: 2015 National Electrical Code: 2014 International Residential Code Edition: 2015 WA Cities Electrical Code: 2014 International Mechanical Code Edition: 2015 WAC 296-466: 2014 Uniform Plumbing Code Edition: 2015 WA State Energy Code: 2015 International Fuel Gas Code: 2015 98118 Contact Person: Name: BILL ALSEPT Address: 3903 SMITH AVE, EVERETT, WA, 98201 Contractor: Name: WILLIAMS MECHANICAL INC Address: 3903 SMITH AVE, EVERETT, WA, 98201 License No: WILLIM1088PA Lender: Name: Address: DESCRIPTION OF WORK: INSTALL ONE 7.5 TON ROOF TOP UNIT AND DUCT SYSTEM Phone: (425) 754-8759 Phone: (425) 303-0828 `" Expiration Date: 10/1/2017 Valuation of Work: $14,800.00 Fees Collected: $389.62 Type of Work: NEW Electrical Service Provided by: PUGET SOUND ENERGY Fuel type: GAS Water District: TUKWILA Sewer District: TUKWILA SEWER SERVICE Current Codes adopted by the City of Tukwila: International Building Code Edition: 2015 National Electrical Code: 2014 International Residential Code Edition: 2015 WA Cities Electrical Code: 2014 International Mechanical Code Edition: 2015 WAC 296-466: 2014 Uniform Plumbing Code Edition: 2015 WA State Energy Code: 2015 International Fuel Gas Code: 2015 I hearby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this development permit and agree to the conditions attached to this permit. ��Signature: c Date: Print This permit shall become null and void if the work is not commenced within 180 days for the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. PERMIT CONDITIONS: 1: Work shall be installed in accordance with the approved construction documents, and any changes made during construction that are not in accordance with the approved construction documents shall be resubmitted for approval. 2: All permits, inspection record card and approved construction documents shall be kept at the site of work and shall be open to inspection by the Building Inspector until final inspection approval is granted. 3: Readily accessible access to roof mounted equipment is required. 4: All construction shall be done in conformance with the Washington State Building Code and the Washington State Energy Code. 5: Remove all demolition rubble and loose miscellaneous material from lot or parcel of ground, properly cap the sanitary sewer connections, and properly fill or otherwise protect all basements, cellars, septic tanks, wells, and other excavations. Final inspection approval will be determined by the building inspector based on satisfactory completion of this requirement. 6: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206-431-3670). 7: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center. 8: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. 9: ***MECHANICAL PERMIT CONDITIONS*** 10: All mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center (206/431-3670). 11: Manufacturers installation instructions shall be available on the job site at the time of inspection. 12: The attached set of mechanical plans have been reviewed by The Tukwila Fire Marshals Office and are acceptable with the following concerns: 13: H.V.A.C. units rated at greater than 2,000 cfm require auto -shutdown devices. These devices shall be separately zoned in the alarm panel and local U.L. central station supervision is required. (City Ordinance #2437) 14: H.V.A.C. systems supplying air in excess of 2,000 cubic feet per minute to enclosed spaces within buildings shall be equipped with an automatic shutoff. Automatic shutoff shall be accomplished by interrupting the power source of the air -moving equipment upon detection of smoke in the main return -air duct served by such equipment. Smoke detectors shall be labeled by an approved agency for air -duct installation and shall be installed in accordance with the manufacturer's installation instructions. (IMC 606.1, 606.2.1) 15: Remote indicator lights are required on all above ceiling smoke detectors. (City Ordinance #2437) 16: Duct smoke detectors shall be capable of being reset from a single point near the alarm panel. (City Ordinance #2437) 17: Duct detectors shall send a supervisory signal only upon activation. (City Ordinance #2437) 18: All new fire alarm systems or modifications to existing systems shall have the written approval of The Tukwila Fire Prevention Bureau. No work shall commence until a fire department permit has been obtained. (City Ordinance #2437) (IFC 901.2) 19: An electrical permit from the City of Tukwila Building Department Permit Center (206-431-3670) is required for this project. 20: Contact The Tukwila Fire Prevention Bureau to witness all required inspections and tests. (City Ordinances #2436 and #2437) 21: Any overlooked hazardous condition and/or violation of the adopted Fire or Building Codes does not imply approval of such condition or violation. 22: These plans were reviewed by Inspector 511. If you have any questions, please call Tukwila Fire Prevention Bureau at (206)575-4407. PERMIT INSPECTIONS REQUIRED Permit Inspection Line: (206) 438-9350 1400 FIRE FINAL 0703 MECH EQUIP EFF 1800 MECHANICAL FINAL 0609 PIPE/DUCT INSULATION 0705 REFRIGERATION EQUIP 0701 ROUGH -IN MECHANICAL CITY OF TUKR__,A Community Development Department Permit Center • 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 ' http://www.TukwilaWA.gov SITE LOCATION Mechanical Permit No. Project No. Date Application Accepted: �-- Date Application Expires: For office use MECHANICAL PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. **please print** > j _ - e�v�_ Lam, King Co Assessor's Tax No.: Site Address:_ (`f ( �//7' <, 4 ZZ4 Suite Number: Floor:—2 Tenant Name: I New Tenant: 5�-- . Yes ❑.. No PROPERTY OWNER Name: Address: City: State: Zip: CONTACT PERSON — person receiving all project communication Name: `/ / LL l�Zs �7 Address: City: State: Zip: PhoneW // vv % Fax: Email: MECHANICAL CONTRACTOR INFORMATION Company Name: Address: S1%% City: Zy State: W. zip: P3 26 Phone: Fax: Contr Reg No.: �D Exp Date: Tukwila Business License No.: Valuation of project (contractor's bid price): $_ /`9 , W Describe the scope of work in detail: 0iS/C� 7" Use: Residential: New.......... ❑ Replacement........ ❑ Commercial: New.......... ❑ Replacement........ ❑ Fuel Type: Electric...... ❑ Gas ........ ❑ Other: H:\Applications\Forms-Applications On Line\2016 Applications\Mechanical Permit Application Revised 1-4-16.docx Revised: January 2016 Page 1 of 2 bh Indicate type of mechanical work being installed and the quantity below: Unit Type Qty Furnace <100k btu Residential, Nighttime Furnace >100k btu ��II N Floor furnace 55 dB(A) Suspended/wall/floor mounted heater 57 dB(A) Appliance vent Commercial Repair or addition to heat/refrig/cooling system 47 dB(A) Air handling unit <10,000 cfm 65 dB(A) Unit Type Qty Air handling unit >I0,000 cfm Residential, Nighttime Evaporator cooler Industrial Ventilation fan connected to single duct Ventilation system 55 dB(A) Hood and duct 57 dB(A) Incinerator — domestic Commercial Incinerator — comm/industrial 47 dB(A) Unit Type Qty Fire damper Residential, Nighttime Diffuser Industrial Thermostat 55 dB(A) Wood/gas stove 57 dB(A) Emergency enerator Commercial Other mechanical equipment 47 dB(A) 60 dB(A) 65 dB(A) Boiler/Compressor Qty 0-3 hp/100,000 btu 3-15 h /500,000 btu 15-30 hp/1,000,000 btu 30-50 hp/1,750,000 btu 50+ h /1,750,000 btu Noise: Mechanical units need to be in compliance with the Tukwila Noise Code. Maximum permissible sound levels are based on from where the sound is created and where the sound is heard. Additionally, if sound can be heard from within a house at night in a residential zone it may not be allowed. For more details, see TMC 8.22 District of Sound Producing Source District of Receiving Property Residential, Daytime* Residential, Nighttime Commercial Industrial Residential 55 dB(A) 45 dB(A) 57 dB(A) 60 dB(A) Commercial 57 dB(A) 47 dB(A) 60 dB(A) 65 dB(A) r77�strial 60 dB(A) 50 dB(A) 65 dB(A) 70 dB(A) *Daytime means 7AM-IOPM, Monday through Friday and 8AM-IOPM, Saturday, Sunday and State -recognized holidays. A few sounds are exempt from the noise code, including: Warning devices; Construction and property maintenance during the daytime hours (lam-IOpm); Testing of backup generators during the day. PERMIT APPLICATION NOTES - Value of construction — in all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the permit center to comply with current fee schedules. Expiration of plan review — applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The building official may grant one extension of time for additional periods not to exceed 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER OR AUTHORIZED AGENT: Signature: 4'1/ Print Name: t4---1Q117k 1 /'1G.;/ Mailing Address: Date: Day Telephone: T66- 1� U � / City State Zip H:\Applications\Forms-Applications On Linc\2016 ApplicationsWechanical Permit Application Revised 1-4-16.docx Revised: January 2016 Page 2 of 2 bh DESCRIPTIONS PermitTRAK ACCOUNT QUANTITY PAID $589.15 EL16-0644 Address: 14520 INTERURBAN AVE S Apn: 3365901630 $72.77 ELECTRICAL $69.30 PERMIT FEE MULTI-FAM/COMM R000.322.101.00.00 0.00 $69.30 TECHNOLOGY FEE $3.47 TECHNOLOGY FEE R000.322.900.04.00 0.00 $3.47 M16-0117 Address: 14520 INTERURBAN AVE S Apn: 3365901630 $389.62 MECHANICAL $374.63 PERMIT ISSUANCE BASE FEE R000.322.100.00.00 0.00 $32.50 PERMIT FEE R000.322.100.00.00 0.00 $267.20 PLAN CHECK FEE R000.322.102.00.00 0.00 $74.93 TECHNOLOGY FEE $14.99 TECHNOLOGY FEE R000.322.900.04.00 0.00 $14.99 PG16-0098 Address: 14520 INTERURBAN AVE S Apn: 3365901630 $126.76 GAS $121.88 PERMIT ISSUANCE BASE FEE 11000.322.100.00.00 0.00 $32.50 PERMIT FEE R000.322.100.00.00 0.00 $65.00 PLAN CHECK FEE R000.322.103.00.00 0.00 $24.38 TECHNOLOGY FEE $4.88 TECHNOLOGY FEE TOTAL FEES PAID BY RECEIPT: .. R000.322.900.04.00 0.00 $4.88 .. .15 Date Paid: Tuesday, July 12, 2016 Paid By: WILLIAM ALSEPT Pay Method: CREDIT CARD 01936D Printed: Tuesday, July 12, 2016 10:23 AM 1 of 1 ��' I��WSYSTEir15 INSPECTION RECORD �= Retain a copy with permit ml& -011 -7 INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Approved per applicable codes. L, Corrections required prior to approval. COMMENTS: Inspector: Date: ( ?7 REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. INSPECTION RECORD —] \W Retain a copy with permit M 16 -0/17 INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Proj t: Type of Inspection: /kG+ivF7 SPICE Com - 6AIaL Address: Date Called: Q Special Instructions: Date Wante• a.m. >/ /6 p.m. Requeste PJICL Phone No: q25 --075N- 67SI 0 Approved per applicable codes. R Corrections required prior to approval. U paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. INSPECTION RECORD 022 Retain a copy with permit mi&._Cj! % INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Project: Type of Inspection: CC— M EC 14A -AA C4 jAIAL Address:Date Called: 4r2o , .tesm7/ - S Special Instructions: Date Wanted: a.m. �� ail ►. � �O P. Requeste RILL Phone No: Approved per applicable codes. 21 Corrections required prior to approval. • ! •tWWW r% •� �� ail ►. � ;. ' �-. IInspector: AA, IDate: 1,/Iq/l6 I REINSPECTION FEE REQUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. INSPECTION RECORD Retain a copy with permitJ�"©fit ? INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd.., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 9Approved per applicable codes. Q Corrections required prior to approval. Inspector: Date//U f REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. INSPECTION RECORD rMlrl Retain, a copy with permit 'fit 0 10 INSPECTION NUMBER PERMIT NUMBERS CITY OF TUKWILA FIRE DEPARTMENT 206-S7S-4407 Project:! 1f^-% tl;�T.. Type of Inspection: Address:- Suite #: a:A- j I `� Cont ct Person: Special Instructions: Phone No.: Approved per applicable codes. F� Corrections required prior to approval. COMMENTS: Sprinklers: Fire Alarm: Hood & Duct: Monitor: Pre -Fire: Permits: Occupancy Type: YQ� Needs Shift Inspection: Sprinklers: Fire Alarm: Hood & Duct: Monitor: Pre -Fire: Permits: Occupancy Type: Inspector:, Date: 1 v/t 2,Ljt H rs.: ❑ $100.00 REINSPECTION FEE REQUIRED. You will receive an invoice from the City of Tukwila Finance Department. Call to schedule a reinspection. Billing Address Attn: Company Name: Address: Ci State: Zi Word/Inspection Record Form.Doc 3/14/14 T.F.D. Form F.P. 113 BALANCING REPORT REPORT REPORT BALANCI REPORT ON � I w J — — __ --- — -- -- ---Co 1. C J I I I I I EGA S-2' CLEAR r---------1 am m r ---------- I I I I I I I I L ---------J IW 3 c � 'c 3 ��ma fa -7 ' '............ .... .................. m p � rpp �0oa r I I I I w r�\V1 I I L----------- �w 1 Zone Checksums By RICE Group Lower Open Office COOLING COIL PEAK Peaked at Time: Mo/Hr: 8 / 18 Outside Air: OADB/WB/HR: 75 / 60 / 57 Space Plenum Net Percent Sens. + Lat. Sens. + Lat Total Of Total Btu/h Btu/h Btu/h (%) Envelope Loads Skylite Solar 0 0 0 0 Skylite Cond 0 0 0 0 Roof Cond 0 0 0 0 CLG SPACE PEAK Mo/Hr: 8 / 18 OADB: 75 Space Percent Sensible Of Total Btu/h (%) 0 0 0 0 0 0 Envelope Loads Skylite Solar Skylite Cond Roof Cond HEATING COIL PEAK Mo/Hr: Heating Design OADB: 26 Space Peak Coil Peak Percent Space Sens Tot Sens Of Total Btu/h Btu/h (%) 0 0 0.00 0 0 0.00 0 0 0.00 TEMPERATURES Cooling Heating SADB 59.0 73.8 Ra Plenum 72.0 69.9 Return 72.0 69.9 Ret/OA 72.1 68.9 Fn MtrTD 0.0 0.0 Fn BIdTD 0.0 0.0 Fn Frict 0.0 0.0 Ent Glass Solar 44,752 0 44,752 81 44,752 83 Glass Solar 0 0 0.00 AIRFLOWS 54.5 3,781 Glass/Door Cond 719 0 719 1 719 1 Glass/Door Cond -8,246 -8,246 40.51 0.0 Cooling Heating Wall Cond 917 158 1,075 2 917 2 Wall Cond -2,410 -2,826 13.88 Partition/Door 0 0 0 0 0 Partition/Door 0 0 0.00 Diffuser 3,781 3,781 Floor 0 0 0 0 0 Floor 0 0 0.00 Terminal 3,781 3,781 Adjacent Floor 0 0 0 0 0 0 Adjacent Floor 0 0 0.00 Main Fan 3,781 3,781 Infiltration 107 107 0 305 1 Infiltration -4,994 -4,994 24.53 Sec Fan 0 0 Sub Total =_> 46,495 158 46,653 84 46,693 86 Sub Total =_> -15,650 -16,066 78.92 Nom Vent 89 89 Vent 89 89 Internal Loads Internal Loads nfU 103 103 Lights 4,166 0 4,166 8 4,166 8 Lights 0 0 0.00 MinStop/Rh 0 0 People 2,955 0 2,955 5 1,642 3 People 0 0 0.00 Return 3,884 3,884 Misc 1,602 0 1,602 3 1,602 3 Misc 0 0 0.00 Exhaust 192 192 Sub Total =_> 8,724 0------8- 7,410 14 Sub Total =_> 0 0 0.00 Rm Exh 0 0 REVIEWEb FOR; Auxiliary 0 0 Ceiling Load 10 10 0,�0 CODEOCOMPIJANCEo 10 0 Ceiling Load -27 0 0.00 Leakage Dwn 0 0 Ventilation Load 0 0 0 Ventilation Load 0 -4,311 21.18 Leakage Ups 0 0 Ad' Air Trans Heat I 0 APPROVED 0 0 0 Ad' Air Trans Heat � 0 0 0 Dehumid. Ov Sizing0 0 Ov/Undr Sizing¢'. RECEIV VIE. 0 0.00 Ov/Undr Sizing Exhaust Heat 0 ti 2 0 0 0 0 Exhaust Heat 19 OA Preheat Di CI` Y OF TUKWILA 0 -0.09 0.00 ENGINEERING CKS Sup. Fan Heat 0 0 RA Preheat Diff. 0 0.00 Cooling Heating Ret. Fan Heat Duct Heat Pkup 0 0 0 0 0 0 Additional Reheat System Plenum Heat JUL 12 2016 0 0 0.00 0.00 % OA cfm/ft2 2.4 4.03 2.4 4.03 Underflr Sup Ht Pkup {�0' olf(3y �f ��'"(if� 0 Underflr Sup Ht Pkup 0 0.00 cfm/ton 818.00 Supply Air Leakage 0 Supply Air Leakage 0 0.00 ft2/ton 203.17 BUILDING DIVISIONE�I� �� Btu/hr•ft2 59.06 -21.29 Grand Total =_> 55,228 54,114 100.00 Grand Total == 5, 358 100.00 No. People 7 Total 4.6 55.5 Project Name: Dataset Name: Interurban.i)-2.trc Leave DB/WB/HR °F °F gr/Ib 59.0 55.0 59.0 0.0 0.0 0.0 0.0 0.0 0.0 7 AREAS COOLING COIL SELECTION Gross Total Total Capacity Ent Sens Cap. Coil Airflow Enter DB/WB/HR ton MBh MBh cfm °F °F gr/Ib Main Clg 4.6 55.5 54.5 3,781 72.1 60.1 59.4 Aux Clg 0.0 0.0 0.0 0 0.0 0.0 0.0 Opt Vent 0.0 0.0 0.0 0 0.0 0.0 0.0 Total 4.6 55.5 Project Name: Dataset Name: Interurban.i)-2.trc Leave DB/WB/HR °F °F gr/Ib 59.0 55.0 59.0 0.0 0.0 0.0 0.0 0.0 0.0 7 HEATING COIL SELECTION AREAS Gross Total Glass Ent Lvg ft2 (%) Floor 939 °F Part 0 -20.0 Int Door 0 73.8 ExFlr 0 0 Roof 0 0 0 Wall 1,050 432 41 Ext Door 42 0 0 HEATING COIL SELECTION CapacityCoil Airflow Ent Lvg MBh cfm °F °F Main Htg -20.0 3,781 69.0 73.8 Aux Htg 0.0 0 0.0 0.0 Preheat 0.0 0 0.0 0.0 Humidif 0.0 0 0.0 0.0 Opt Vent 0.0 0 0.0 0.0 Total -20.0 TRACE® 700 v6.3.1 calculated at 05:11 PM on 03/29/2016 Alternative - 1 System Checksums Report Page 2 of 6 41 Mezzanine Storage COOLING COIL PEAK Tot Sens Of Total Btu/h Peaked at Time: Mo/Hr: 7 / 19 3,851 Outside Air: OADB/WB/HR: 74 / 58 / 49 People Space Plenum Net Percent Sens. + Lat. Sens. + Lat Total Of Total Btu/h Btu/h Btu/h (%) Envelope Loads 0 8,064 27 Skylite Solar 997 0 997 3 Skylite Cond 0 13 13 0 Roof Cond 0 1,120 1,120 4 Glass Solar 19,077 0 19,077 64 Glass/Door Cond 216 0 216 1 Wall Cond 318 100 417 1 Partition/Door 0 Exhaust Heat 0 0 Floor 0 0 0 0 Adjacent Floor 0 0 0 0 Infiltration -10 0 -10 0 Sub Total =_> 20,598 1,233 21,831 73 Internal Loads Tot Sens Of Total Btu/h COOLING COIL SELECTION 0 Lights 3,851 0 3,851 13 People 2,731 0 2,731 9 Misc 1,481 0 1,481 5 Sub Total =_> 8,064 0 8,064 27 Ceiling Load 203 -203 0 0 Ventilation Load 0 0 -9 0 Adj Air Trans Heat 0 0.0 0.0 0 0 Dehumid. Ov Sizing Leakage Dwn 0 0 0 Ov/Undr Sizing 0 0 0 Exhaust Heat -137 -137 0 Sup. Fan Heat 0 0 Ret. Fan Heat 0 0 0 Duct Heat Pkup 0 0 0 Underflr Sup Ht Pkup 0 0 Supply Air Leakage 0 0 0 Grand Total ==> 28,865 893 29,749 100.00 Zone Checksums By RICE Group CLG SPACE PEAK Mo/Hr: 7 / 19 OADB: 74 Space Percent Sensible Of Total Btu/h (%) 997 4 0 0 0 0 19,077 69 216 1 318 1 0 0 0 0 0 0 152 1 20,760 75 3,851 14 1,517 5 1,481 5 6,850 25 203 1 0 0 0 0 0 0 27,813 100.00 Total 2.5 29.8 Project Name: Dataset Name: Interurban C-2.trc HEATING COIL PEAK Mo/Hr: Heating Design OADB: 26 °nvelope Loads Skylite Solar Skylite Cond Roof Cond Glass Solar Glass/Door Cond Wall Cond Partition/Door Floor Adjacent Floor Infiltration Sub Total =_> nternal Loads Lights People Mise Sub Total =_> veiling Load /entilation Load kdj Air Trans Heat )v/Undr Sizing ?xhaustHeat )A Preheat Diff. ZA Preheat Diff. \dditional Reheat iystem Plenum Heat Jnderflr Sup Ht Pkup Supply Air Leakage 3rand Total ==> Leave DB/WB/HR °F °F gr/Ib 55.0 51.2 50.8 0.0 0.0 0.0 0.0 0.0 0.0 Space Peak Space Sens Btu/h 0 0 0 0 -2,403 -929 0 0 0 -4,197 -7,529 MI H N -288 0 0 0 -7,817 Coil Peak Percent Tot Sens Of Total Btu/h COOLING COIL SELECTION 0 0.00 Total Capacity 1.34 Sens Cap. Coil Airflow Enter DB/WB/HR 0.00 ton MBh MBh cfm °F °F gr/Ib Main Clg 2.5 29.8 28.9 1,489 72.8 58.5 51.5 Aux Clg 0.0 0.0 0.0 0 0.0 0.0 0.0 Opt Vent 0.0 0.0 0.0 0 0.0 0.0 0.0 Total 2.5 29.8 Project Name: Dataset Name: Interurban C-2.trc HEATING COIL PEAK Mo/Hr: Heating Design OADB: 26 °nvelope Loads Skylite Solar Skylite Cond Roof Cond Glass Solar Glass/Door Cond Wall Cond Partition/Door Floor Adjacent Floor Infiltration Sub Total =_> nternal Loads Lights People Mise Sub Total =_> veiling Load /entilation Load kdj Air Trans Heat )v/Undr Sizing ?xhaustHeat )A Preheat Diff. ZA Preheat Diff. \dditional Reheat iystem Plenum Heat Jnderflr Sup Ht Pkup Supply Air Leakage 3rand Total ==> Leave DB/WB/HR °F °F gr/Ib 55.0 51.2 50.8 0.0 0.0 0.0 0.0 0.0 0.0 Space Peak Space Sens Btu/h 0 0 0 0 -2,403 -929 0 0 0 -4,197 -7,529 MI H N -288 0 0 0 -7,817 Coil Peak Percent Tot Sens Of Total Btu/h (%) 0 0.00 -179 1.34 -1,145 8.53 0 0.00 -2,403 17.90 -1,228 9.15 0 0.00 0 0.00 0 0.00 -4,197 31.26 -9,152 68.18 0 0.00 0 0.00 0 0.00 0 0.00 0 0.00 -3,985 29.69 0 0 0 0.00 195 -1.45 0 0.00 0 0.00 0 0.00 -480 3.58 0 0.00 0 0.00 -13,423 100.00 TEMPERATURES AREAS Cooling Heating Gross Total Glass 74.8 Ra Plenum 72.7 ft2 (%) Floor 868 Ret/OA 72.8 Part 0 0.0 0.0 Int Door 0 0.0 Fn Frict ExFlr 0 87 MinStop/Rh Roof 868 8 1 Wall 402 132 33 Ext Door 0 0 0 TEMPERATURES Cooling Heating SADB 55.0 74.8 Ra Plenum 72.7 69.0 Return 72.7 69.0 Ret/OA 72.8 66.6 Fn MtrTD 0.0 0.0 Fn BIdTD 0.0 0.0 Fn Frict 0.0 0.0 AIRFLOWS Cooling Heating Cooling Heating Diffuser 1,489 1,489 Terminal 1,489 1,489 Main Fan 1,489 1,489 Sec Fan 0 0 Nom Vent 82 82 AHU Vent 82 82 Infil 87 87 MinStop/Rh 0 0 Return 1,576 1,576 Exhaust 169 169 Rm Exh 0 0 Auxiliary 0 0 Leakage Dwn 0 0 Leakage Ups 0 0 ENGINEERING CKS Cooling Heating % OA 5.5 5.5 cfm/ft, 1.72 1.72 cfm/ton 600.63 ft2/ton 350.13 Btu/hr•ft2 34.27 -13.60 No. People 6 HEATING COIL SELECTION CapacityCoil Airflow Ent Lvg MBh cfm °F °F Htg -11.8 1,489 67.6 74.8 Htg 0.0 0 0.0 0.0 eat 0.0 0 0.0 0.0 idif 0.0 0 0.0 0.0 lent 0.0 0 0.0 0.0 1 -11.8 TRACE® 700 v6.3.1 calculated at 05:11 PM on 03/29/2016 Alternative - 1 System Checksums Report Page 4 of 6 k WYORK [FaLm SUBMITTAL DATA For: Approval Order #: Date: 04/22/2016 Project: 1)200 Williams Mech. Project #: EH04222016-01 Location: Purchaser: BILL WILLIAMS MECH. Submitter: ERIK YORK NW JCI REVIEWED FOR CODE COMPLIANCE APPROVED JUL 2 6 2016 city of Tukwila BUILDING DIVISION Unitary Sales Tool 0.5.9.0 RECEIVED CITY OF TUKWILA Mid-oiii Information is subject to change without notice. Check local codes. JUL 12 2016 PERMIT CENTER Printed 04/22/2016 Date 04/22/2016 Project Name C 200 Williams Mech. Project Number WYORK EH04222016-01 Client / Purchaser BILL WILLIAMS MECH. Submittal Summary Page Qty Tag # Model # Description 1 ZXG08E4B1AA1 B111A2 7.5 Ton, York Direct Fit Single Packaged R-41 OA Air Conditioner, 11.0 EER / 11.5 IEER, Two Stage Cooling, Gas Heat, 180 Mbh Two Stage Input Medium Heat Aluminized Gas, 460-3-60 • Medium Static Belt Drive Blower • Copper Tube/Aluminum Fin Indoor Coil • Tube and Fin Condenser Coil • Simplicity® SE Controller including Discharge Air, Return Air, and Outdoor Air Temperature Sensors • Dry Bulb Economizer (Downflow only) (with Barometric Relief) with Economizer Fault Detection & Diagnostic 1 1RC0457 Curb Rigid 14" Large Footprint Equipment start-up and commissioning by a factory trained technician is recommended. 1 .. Contact your supplying distributor or sales representative for additional information & guidance. Unitary Sales Tool 0.5.9.0 Information is subject to change without notice. Check local codes. Printed 04/22/2016 0211111111111111 Prestige Page: 3 i3YORK Single Package R-410A Air Conditioner Project Name: C 200 Williams Mech. Unit Model* ZXG08E4B1AA1B111A2 Quantity: 1 System: ZXG08E4B1AA1B111A2 L;ooiing verrormance Total capacity 94.9 MBH Sensible capacity 67.4 MBH Refrigerant type R -410A Efficiency (at ARI) 11.00 EER Integrated eff. (at ARI) 11.50 IEER Ambient DB temp. 95.0 °F Entering DB temp. 80.0 °F Entering WB temp. 67.0 °F Leaving DB temp. 59.2 °F Leaving WB temp. 57.0 °F Power input (w/o blower) 6.63 kW Sound power - 84 dB(A) Gas Heating Performance Entering DB temp. 60 °F Heating output capacity (Max) 144 MBH Supply air 3000 CFM Heating input capacity (Max) 180 MBH Leaving DB temp. 104.4 °F Air temp. rise 44.4 °F SSE 80.0 % Stages 2 Supply Air Blower Performance Supply air 3000 CFM Ext. static pressure 0.6 IWG Addl. Unit Losses (Options/Accessories) 0.17 IWG Blower speed 815 RPM Max BHP of Motor (including service factor) 2.90 HP Duct location Bottom Actual required BHP 1.56 HP Power input 1.44 kW Elevation 0 ft. Drive type BELT Electrical Data Power supply 460-3-60 Unit min circuit ampacity 19.7 Amps Unit min over -current protection 20 Amps Unit max over -current protection 25 Amps Dimensions & Weight Hgt 41 in. Len 87 in. Wth 62 in. Weight with factory installed options 903 lbs. Clearances Right 18 in. Front 48 in. Back 36 in. _r__ 77 in a—++-- 1 in 1 vN 17 in Note: Please refer to the tech guide for listed maximum static pressures c us,= 7.5 Ton • All units are manufactured at an ISO 9001 registered facility and each rooftop is completely computer -run tested prior to shipment. Unit Features • Unit Cabinet Constructed of Powder Painted Steel, Certified At 1000 Hours Salt Spray Test (ASTM B-117 Standards) • Either supply and/or return can be field converted from vertical to horizontal configuration without cutting panels. • Full perimeter base rails with built in rigging capabilities • Scroll Compressors • Solid Core Liquid Line Filter Driers • Tube and Fin Condenser Coil • 180 Mbh Two Stage Input Medium Heat Aluminized Gas • Medium Static Belt Drive Blower • Unit Ships with 2" Throwaway Filters with a Standard Filter Rack that will Accept up to 4" Filters • Replacement Filters: 4 - (16" x 20"). Unit accepts 2" wide filter. • Single Point Power Connection • Short Circuit Current: 5kA RMS Symmetrical Standard Unit Controller: Simplicity SE Control Board • An Integrated Low -Ambient Control, Anti -Short Cycle Protection, Lead -Lag, Fan On and Fan off Delays, Low Voltage Protection, On -Board Diagnostic and Fault Code Display. Allows all units to operate in the cooling mode down to 0 °F outdoor ambient without additional components or intervention. • Safety Monitoring - Monitors the high and low-pressure switches, the freezestats, the gas valve, if applicable, and the temperature limit switch on gas and electric heat units. The unit control board will alarm on ignition failures, safety lockouts and repeated limit switch trips. BAS Controller • Simplicity SE Controller including Discharge Air, Return Air, and Outdoor Air Temperature Sensors Warranty • One (1) Year Limited Warranty on the Complete Unit • Five (5) Year Warranty - Compressors • Ten (10) Year Warranty -Aluminized Steel Tubular Heat Exchangers Unitary Sales Tool 0.5.9.0 Information is subject to change without notice. Check local codes. Printed 04/22/2016 I Prestige Single Package R410A Air Conditioner Project Name: C 200 Williams Mech. Unit Model* ZXG08E4B1AA1B111A2I Quantity: 1 System: ZXG08E461AA16111A2 Factory Installed Options ZXG08E4B1 AA1 B111 A2 Product category: ZX Neat Type: G Nominal Cooling Capacity: 08 Heat Size: I E voltage: 4 Airflow: B Airflow Options: 1 Coil Options: I A Controls: I A Sensor Options: 1 Economizer l Damper: B Convenience Outlet: 1 Electrical Options: 1 Cabinet Options: 1 Special Options: A 1 RC0457 - Curb Rigid 14" Large Footprint (135.0 lbs) Product Generation:) 2 York Direct Fit Single Packaged R-41 OA Air Conditioner J Gas Heat 7.5 Ton 11.0 EER / 11.5 JEER Two Stage Cooling 180 Mbh Two Stage Input Medium Heat Aluminized Gas 460-3-60 Medium Static Belt Drive Blower Copper Tube/Aluminum Fin Indoor Coil Tube and Fin Condenser Coil Simplicity® SE Controller including Discharge Air, Return Air, and Outdoor Air Temperature Sensors Dry Bulb Economizer (Downflow only) (with Barometric Relief) with Economizer Fault Detection & Diagnostic Field Installed Accessories nitary Sales Tool 0.5.9.0 Information is subject to change without notice. Check local codes. Printed 04/22/2016 d C O O U m = a o T i� Y V t0 CL _d co C a N N a a T T T T MT TTM W W as LU w Go co ti CD N N k E co Q: C0 U) G C m m 1000 V u W Q 'y u N �zs � M N C d � V1 C rV 1 N M �D 1- M u�i p �m u � V u M N n c� n M n Q O 3 V E V d 00 � V1 Z d O O Q t) CZ c H p m H W A vi eC• a d O w O O Z ono =Uo Ooc Wv Q r- r Q O N} w w C> CD 3C O N w p l.9 V 5 3 3 C W mm O Q2 W N DO W N o E m M Q C W LL r > 3 V `�'��~'�vdpOZaZpLLpzo3pzar ..Oww¢�LLm�.m 3 C O Z OOONC62�d2 Ow V C�-I V �r DOvi 1-2 00 c� m X Z W M M M , N � ^ � N n °O r-1 \O T •- nM Mu CCS N 2 R m m 1000 V u W Q 'y u N �zs � M N C d � V1 C rV 1 N M �D 1- 3 i) 0 V M u�i p � m m m m u � V u M N n c� n M n Q O 3 V E V d 00 � V1 Z d O O t) CZ c H p m H W A vi eC• a d O w O O Z ono =Uo Ooc Wv Q r- r Q O N} w w C> CD E m ovi a N w p l.9 V 5 3 3 C W mm O Q2 W N DO W N o E W V V S E S C L O p Q V O H O d ri Z Z O w I~- i S O 1¢�- F~a- ~ m W dp -~Q la/1QQ ul=7 `n�uzovi oz .Z.J Vl O C- Z lN/1 I --I wig Q C W cc Z a > 3 V `�'��~'�vdpOZaZpLLpzo3pzar ..Oww¢�LLm�.m 3 C O Z OOONC62�d2 Ow V C�-I V �r DOvi 1-2 00 c� m 3 i) 0 V M u�i p � m m m m u � V u M N n c� n M n N M NOAH } 1I n 00 N t!1 u 1 u u 7 d C I W i C9 Prestige Page: 6 w RK Single Package R -410A Air Conditioner Project Name: C 200 Williams Mech. Unit Model #: ZXG08E4B1AA1B111A2 Quantity: 1 System: ZXG08E4B1AA1B111A2 Vertical Flow Dry Bulb Economizer Small Footprint 55 Vertical Flow Dry Bulb Economizer Large Footprint 60 Horizontal Flow Dry Bulb Economizer Small Footprint Short 74 Horizontal Flow Dry Bulb Economizer Small Footprint Tall 76 Horizontal Flow Dry Bulb Economizer Large Footprint Short 79 Horizontal Flow Dry Bulb Economizer Large Footprint Tall 82 Power Exhaust Vert Flow Small Footprint 55 Power Exhaust Vert Flow Large Footprint 75 Power Exhaust Horiz Flow Small Footprint 40 Power Exhaust Horiz Flow Large Footprint 80 Hail Guard Kit Small Short Factory Installed 18 Hail Guard Kit Small Tall Factory Installed 23 Hail Guard Kit Large Short Factory Installed 36 Hail Guard Kit Large Tall Factory Installed 44 Curb Rigid 14" Small Footprint 94 Curb Rigid 14" Large Footprint 126 Curb Rigid 24" Small Footprint 148 Curb Rigid 24" Large Footprint 222 Unitary Sales Tool 0.5.9.0 Information is subject to change without notice. Check local codes. Printed 04/22/2016 WYORK Prestige Page: 7 Single Package R -410A Air Conditioner Project Name: C 200 Williams Mech. Unit Model #: ZXG08E4B1AA1B111A2 Quantity: 1 System: ZXG08E4B1AA1B111A2 81.750 O.D. 78.250 I.D. 15.469 50.00 I. D. Qv RIGHT 34.313 �JQ 31.531 11.417 15.813 6.043 4.173 26.00 FRONT 24.813 84.00 O.D. X 53.50 O.D. 81.746 —►I 53.496 1 RC0457 X= 14" Height 1 RC0459 X= 24" Height Notes: 1. Sides, ends, unit locator and cross support are 18-G90. Deck pans, R/A & S/A supports are 20-G90. 2. Full perimeter wood nailer. 3. Insulated deck pans. Unit Models used with 1 RC0457, 1 RC0459 Roof Curb ZX08 ZY07 ZX09 ZY08 ZX12 ZY09 ZX14 ZY12 Unitary Sales Tool 0.5.9.0 Information is subject to change without notice. Check local codes. Printed 04/22/2016 MYORK Guide Specification for Page:8 Prestige 3 00 00 HEATING VENTILATING, AND AIR-CONDITIONING(HVAC) 23 06 00 Schedules for HVAC 23 06 80 Schedules for Decentralized HVAC Equipment 23 06 80. 13 Decentralized Unitary HVAC Equipment Schedule 23 06 80. 13.A Rooftop unit schedule 23 07 00 HVAC Insulation 23 07 16 HVAC Equipment Insulation 23 07 16. 13 Decentralized, Rooftop Units 23 07 16. 13.A Evaporator fan compartment 1. Interior cabinet surfaces shall be insulated with a minimum 1/2- in. thick, minimum 1 1/2 Ib density, flexible fiberglass insulation bonded with a phenolic binder, neoprene coated on the air side. 2. Insulation and adhesive shall meet NFPA 90A requirements for flame spread and smoke generation. 23 07 16. 13.6 Gas heat compartment 1. Aluminum foil -faced fiberglass insulation shall be used. 2. Insulation and adhesive shall meet NFPA 90A requirements for flame spread and smoke generation. 23 09 00 Instrumentation and Control for HVAC 23 09 13. 23 Sensors and Transmitters 23 09 13. 23.A Thermostats 1. Thermostat must: a. energize "G" when calling for fan only or continuous fan. b. have capability to energize 2 different stages of cooling, and 2 different stages of heating. c. include capability for occupancy scheduling. 23 09 23 Direct -digital Control system for HVAC 23 09 23. 13 Decentralized, Rooftop Units 23 09 23. 13.A Simplicity SE (Unit based microprocessor control) 1. Shall be ASHRAE 62-2001 compliant. 2. Shall include an integrated economizer controller to support an economizer with 4 to 20 mA actuator input. 3. Controller shall accept the following inputs: space temperature, setpoint adjustment, outdoor air temperature, indoor air quality, outdoor air quality, indoor relative humidity, compressor lockout, fire shutdown, enthalpy, fan status, remote time clock/door switch. 4. Shall accept a CO2 sensor in the conditioned space, and be Demand Control Ventilation ready. 5. Unit shall provide surge protection for the controller through a circuit breaker. 6. Shall have an LED display independently showing the status of activity on the communication bus, and processor operation. 7. Software upgrades will be accomplished by local download. Software upgrades through chip replacements are not allowed. -i acs Guide Specification for Page:9 MY01K Prestige A. Unit shall be complete with self-contained low-voltage control circuit protected by a resettable circuit breaker on the 24-volt transformer side. B. Unit shall incorporate a lockout circuit which provides reset capability at the space thermostat or base unit should any of the following standard safety devices trip and shut off compressor: C. Loss-of-charge/Low-pressureswitch. D. High-pressure switch. E. Freeze-protection thermostat, evaporator coil. If any of the above safety devices trip, an LED (light-emitting diode) indicator shall flash a diagnostic code that indicates which safety switch has tripped. F. Unit shall incorporate "AUTO RESET" compressor over temperature, over current protection. G. Unit shall operate with conventional thermostat designs and have a low voltage terminal strip for easy hook-up. H. Unit control board shall have on -board diagnostics and fault code display. I. Standard controls shall include anti -short cycle and low voltage protection, and permit cooling operation down to 0 OF. J. Control board shall monitor each refrigerant safety switch independently. K. Control board shall retain last 5 fault codes in non-volatile memory, which will not be lost in the event of a power loss. 23 09 23. 13.6 RTU Open -multi -protocol, direct digital controller 1. Shall be ASHRAE 62-2001 compliant. 2. Shall include built-in protocol for BACNET , Modbus , and Johnson N2. 3. Shall allow access of up to 62 network variables (SNVT). Shall be compatible with all open controllers 4. Baud rate Controller shall be selectable using a dipswitch. 5. Shall have an LED display independently showing the status of serial communication, running, errors, power, all digital outputs, and all analog inputs. 6. Shall accept the following inputs: space temperature, setpoint adjustment, outdoor air temperature, indoor air quality, outdoor air quality, compressor lock- out, fire shutdown, enthalpy switch, and fan status/filter status/ humidity/ remote occupancy. 7. Software upgrades will be accomplished by either local or remote download. No software upgrades through chip replacements are allowed. 23 09 33 Electric and Electronic Control System for HVAC 23 09 33. 13 Decentralized, Rooftop Units 23 09 33. 13.A General 1. Shall be complete with self- contained low- voltage control circuit protected by a resettable circuit breaker on the 24-v transformer side. Transformer shall have 75VA capability. 2. Shall utilize color -coded wiring. 3. Shall include a central control terminal board to conveniently and safely provide connection points for vital control functions such as: smoke detectors, phase monitor, gas controller, economizer, thermostat, DDC control options, and low and high pressure switches. 4. The heat exchanger shall be controlled by an integrated gas controller (IGC) microprocessor. See heat exchanger section of this specification. 23 09 33. 23.13 Safeties 1. Compressor over -temperature, over -current. High internal pressure differential. 2. Low-pressure switch. a. Units with 2 compressors shall have different sized connectors for the circuit 1 and circuit 2 low and high pressure switches. They shall physically prevent the cross- wiring of the safety switches between circuits 1 and 2. b. Low pressure switch shall use different color wire than the high pressure switch. The purpose is to assist the installer and service technician to correctly wire and or troubleshoot the rooftop unit. 3. High pressure switch. a. Units with 2icompressors shail�have different sized connectors for the circuit 1 and circuit 2 low:and high pressure switches. They shall physically prevent the cross -wiring of the safety switches between circuits 1 and 2. 00111111111111yo Guide Specification for Page: 10 im RK Prestige b. High pressure switch shall use different color wire than the low pressure switch. The purpose is to assist the installer and service technician to correctly wire and or troubleshoot the rooftop unit. 4. Automatic reset,/motor thermal overload protector. 5. Heating section shall be provided with the following minimum protections: a. High-temperature limit switches. b. Induced draft motor speed sensor. c. Flame rollout switch. d. Flame proving controls 23 09 93 Sequence of Operations for HVAC Controls 23 09 93. 13 Decentralized, Rooftop Units 23 09 93. 13 INSERT SEQUENCE OF OPERATION 23 40 13 Panel Air Filters 23 40 13. 13 Decentralized, Rooftop Units 23 40 13. 13.A Standard filter section 1. Shall consist of factory -installed, low velocity, disposable 2" thick fiberglass filters of commercially available sizes. 2. Units can accept 2" or 4" filters and have a field convertible toolless 3. Filters shall be accessible through an access panel with toolless removal as described in the unit cabinet section of this specification (23 81 19.13.H). 23 81 19 Self -Contained Air Conditioners 23 81 19. 13 Small -Capacity Self -Contained Air Conditioners 23 81 19. 13.A General 1. Outdoor, rooftop mounted, electrically controlled, heating and cooling unit utilizing a fully hermetic scroll compressor(s) for cooling dutyand gas combustion for heating duty. 2. Factory assembled, single -piece heating and cooling rooftop unit. Contained within the unit enclosure shall be all factory wiring, piping, controls, and special features required prior to field start-up. 3. Unit shall use environmentally sound, R -410A refrigerant. 4. Unit shall be installed in accordance with the manufacturer's instructions. 5. Unit must be selected and installed in compliance with local, state, and federal codes. 23 81 19. 13.13 Quality Assurance 1. Unit meets ASHRAE 90.1 minimum efficiency requirements. 3. Unit shall be rated in accordance with AHRI Standards 210/240 and 340/360. 4. Unit shall be designed to conform to ASHRAE 15, 2001. 5. Unit shall be UL -tested and certified in accordance with ANSI Z21.47 Standards and UL -listed and certified under Canadian standards as a total package for safety requirements. 6. Insulation and adhesive shall meet NFPA 90A requirements for flame spread and smoke generation. 7. Unit casing shall be capable of withstanding 1000 -hour salt spray exposure per ASTM 8117 (scribed specimen). 8. Unit shall be designed in accordance with ISO 9001, and shall be manufactured in a facility registered by; ISO 9001. 9. Roof curb shall be designed to conform to NRCA Standards. 10. Unit shall be subjected to a completely automated run test on the assembly line. The data for each unit; will be stored at the factory, and must be available upon request. 11. Unit shall be designed in accordance with UL Standard 1995, including tested to withstand rain. 12. - Unit shake tested to assurance level 1, ASTM D4169 to ensure shipping reliability. .,.. .. ... � is � 13. High Efficient Motors listed shall meet section X13 of the Eriergy Independence and Security Act of 20157; ( 15`Q 6 7). MYORK Guide Specification for Page: 11 Prestige 23 81 19. 13.6 Delivery, Storage, and Handling 1. Unit shall be stored and handled per manufacturer's recommendations. 23 81 19. 13.E Project Conditions 1. As specified in the contract. 23 81 19. 131 Operating Characteristics 1. Unit shall be capable of starting and running at 125°F (52°C)ambient outdoor temperature, meeting maximum load criteria of AHRI Standard 210/240 or 340/360 at t 10% voltage. 1. Compressor with standard controls shall be capable of operation down to 0°F (2°C), ambient outdoor temperatures. See below for head pressure control package or winter start kit. 3. Unit shall discharge supply air vertically or horizontally as shown on contract drawings. 4. Unit shall be factory configured for vertical supply & return configurations. 5. Unit shall be field convertible from vertical to horizontal airflow on all models. 6. Unit shall be capable of mixed operation: vertical supply with horizontal return or horizontal supply with vertical return. 23 81 19. 13.G Electrical Requirements 1. Main power supply voltage, phase, and frequency must match those required by the manufacturer. 23 81 19. 13.H Unit Cabinet 1. Unit cabinet shall be constructed of galvanized steel with exterior surfaces coated with a non -chalking, powder paint finish, certified at 1000 hour salt spray test per ASTM -8117 standards. 2. Evaporator fan compartment interior cabinet insulation shall conform to AHRI Standards 210/240 or 340/360 minimum exterior sweat criteria. Interior surfaces shall be insulated with a minimum 1/2- in. thick, 1 Ib density, flexible fiberglass insulation, neoprene coated on the air side. Aluminum foil- faced fiberglass insulation shall be used in the gas heat compartment. Fan shall be a belt drive assembly and include an adjustable pitch motor pulley. Fan wheel shall be double inlet type with forward curve blades, dynamically balanced to operate smoothly throughout the entire range of operation. Airflow design shall be constant volume. Bearings shall be sealed and permanently lubricated for longer life and no maintenance. Entire blower assembly and motor shall be slide out design. 3. Condenser Fan Assembly: The outdoor fans shall be of the direct drive type, discharge air vertically, have aluminum blades riveted to corrosion resistant steel spider brackets and shall be dynamically balanced for smooth operation. The outdoor fan motors shall have permanently lubricated bearings internally protected against overload conditions and staged independently. A cleaning window shall be provided on two sides of the units for coil cleaning. 4. Base of unit shall have a minimum of four locations for thru-the-base gas and electrical connections (factory installed or field installed), standard. 5. Base Rail a. Unit shall have base rails on a minimum of 4 sides. b. Holes shall be provided in the base rails for rigging shackles to facilitate maneuvering and overhead rigging. c. Holes shall be provided in the base rail for moving the rooftop by fork truck.. d. Base rail shall be a minimum of 16 gauge thickness. 6. Condensate pan and connections a. Shall be an internally sloped condensate drain pan made of a non -corrosive material. b. Shall comply with ASHRAE Standard 62. c. Shall use a 3/4" - 14 NPT drain connection, possible either through the bottom or side of the drain pan. Connection shall be made per manufacturer's recommendations. 7. Top panel a. Shall be a single piece top panel. 8. Gas Connections a. All gas piping connecting to unit gas valve shall enter the unit cabinet at a single location on side of unit b. Thru-the-base capability (1.) Standard unit shall have a thru-the-base gas- line location using a raised, embossed portion of the unit basepan. (2.) Optional, factory- approved, water- tight connection method must be used for thru-the-base gas connections. (3.) No basepan penetration, other than those authorized by the manufacturer, is permitted. `i6 ' MYORK Guide Specification for Page: 12 Prestige 9. Electrical Connections a. All unit power wiring shall enter unit cabinet at a single, factory -prepared, knockout location. b. Thru-the-base capability. (1.) Standard unit shall have a thru-the-base electrical location(s) using a raised, embossed portion of the unit basepan. (2.) Optional, factory- approved, water -tight connection method must be used for thru-the-base electrical connections. (3.) No basepan penetration, other than those authorized by the manufacturer, is permitted. 10. Component access panels (standard) a. Cabinet panels shall be easily removable for servicing. b. Unit shall have one factory installed, toolless, removable, filter access panel. c. Panels covering control box, indoor fan, indoor fan motor, gas components(where applicable), and compressors shall have a molded composite handles. d. Handles shall be UV modified, composite. They shall be permanently attached, and recessed into the panel. e. Screws on the vertical portion of all removable access panel shall engage into heat resistant, molded composite collars. f. Collars shall be removable and easily replaceable using manufacturer recommended parts. 23 81 19. 13.1 Gas Heat 1. General a. Heat exchanger shall be an induced draft design. Positive pressure heat exchanger designs shall not be allowed. b. Shall incorporate a direct- spark ignition system and redundant main gas valve. c. Gas supply pressure at the inlet to the rooftop unit gas valve must match that required by the manufacturer. 2. The heat exchanger shall be controlled by an integrated gas controller (IGC) microprocessor. a. IGC board shall notify users of fault using an LED (light -emitting diode). b. The LED shall be visible without removing the control box access panel. c. IGC board shall contain algorithms that modify evaporator -fan operation to prevent future cycling on high temperature limit switch. d. Unit shall be equipped with anti -cycle protection with one short cycle on unit flame rollout switch or 4 continuous short cycles on the high temperature limit switch. Fault indication shall be made using an LED. 3. Standard Heat Exchanger construction a. Heat exchanger shall be of the tubular -section type constructed of a minimum of 20 -gauge steel coated with a nominal 1.2 mil aluminum -silicone alloy for corrosion resistance. b. Burners shall be of the in -shot type constructed of aluminum -coated steel. c. Burners shall incorporate orifices for rated heat output up to 2000 ft (610m) elevation. Additional accessory kits may be required for applications above 2000 ft (610m) elevation, depending on local gas supply conditions. d. Each heat exchanger tube shall contain multiple dimples for increased heating effectiveness. 6. Induced draft combustion motor and blower a. Shall be a direct -drive, single inlet, forward -curved centrifugal type. b. Shall be made from steel with a corrosion -resistant finish. c. Shall have permanently lubricated sealed bearings. d. Shall have inherent thermal overload protection. e. Shall have an automatic reset feature. 23 81 19. 13.J Coils Standard Aluminum Fin/Copper Tube Coils a. Standard evaporator and condenser coils shall have aluminum lanced plate fins mechanically bonded to seamless internally grooved copper tubes with all joints brazed. b. Evaporator coils shall be leak tested to 150 psig, pressure tested to 450 psig, and qualified to UL 1995 burst test at 1775 psig. F c. Condenser coils sh`all-be leak tested to'155,0'ps`ig, pressure tested to 650 psig, and qualified to UL 1995 burstlest at 1980 psig. OYORK Guide Specification for Page: 13 Prestige 23 81 19. 13.K Refrigerant Components 1. Refrigerant circuit shall include the following control, safety, and maintenance features a. Thermostatic Expansion Valve (TXV) shall help provide optimum performance across the entire operating range. Shall contain removable power element to allow change out of power element and bulb without removing the valve body.(Orifice on 3-5 Ton Units) b. Refrigerant filter drier - Solid core design. c. Service gauge connections on suction and discharge lines. d. Pressure gauge access through a specially designed access port in the top panel of the unit. 2. There shall be gauge line access port in the skin of the rooftop, covered by a black, removable plug. a. The plug shall be easy to remove and replace. b. When the plug is removed, the gauge access port shall enable maintenance personnel to route their pressure gauge lines. c. This gauge access port shall facilitate correct and accurate condenser pressure readings by enabling the reading with the compressor access panel on. d. The plug shall be.made of a leak proof, UV- resistant, composite material. 3. Compressors a. Unit shall use fully hermetic, scroll compressor for each independent refrigeration circuit. b. Compressor motors shall be cooled by refrigerant gas passing through motor windings. c. Compressors shall be internally protected from high discharge temperature conditions. d. Compressors shall be protected from an over -temperature and over -amperage conditions by an internal, motor overload device. e. Compressor shall be factory mounted on rubber grommets. f. Compressor motors shall have internal line break thermal, current overload and high pressure differential protection. g. Crankcase heaters shall not be required for normal operating range, unless provided by the factory. 23 81 19. 131 Filter Section 1. Filters access is specified in the unit cabinet section of this specification. 2. Shall consist of factory -installed, low velocity, throw -away 2" thick fiberglass filters. 3. Units can accept 2" or 4" filters and have a field convertible toolless 23 81 19. 13.M Evaporator Fan and Motor 1. Evaporator fan motor a. Shall have permanently lubricated bearings. b. Shall have inherent automatic -reset thermal overload protection or circuit breaker. 3. Belt -driven Evaporator Fan a. Belt drive shall include an adjustable -pitch motor pulley. b. Shall use sealed, permanently lubricated ball-bearing type. c. Blower fan shall be double -inlet type with forward -curved blades. d. Shall be constructed from steel with a corrosion resistant finish and dynamically balanced. 23 81 19. 13.N Condenser Fans and Motors The outdoor fans shall be of the direct drive type, discharge air vertically, have aluminum blades riveted to corrosion resistant steel spider brackets and shall be dynamically balanced for smooth operation. The outdoor fan motors shall have permanently lubricated bearings internally protected against overload conditions and staged independently. A cleaning window shall be provided on two sides of the units for coil cleaning. 1. Condenser fan motors a. Shall be a totally enclosed motor. b. Shall use permanently lubricated bearings. c. Shall have inherent thermal overload protection with an automatic reset feature. d.�, :;AI'models shall use a.shaft-down design except shaft -up or-, ZX'i4 x ZY12 size with rain shield. 2. Condenser Fans K'vMlY0jFKGuide Specification for Page: 14 0 Prestige a. Shall be a direct -driven propeller type fan. b. Shall have aluminum blades riveted to corrosion -resistant steel spiders and shall be dynamically balanced. 23 81 19. 13.0 Special Features Options and Accessories 3. Standard Integrated Economizers: a. Integrated, gear -driven opposing modulating blade design type capable of simultaneous economizer and compressor operation. b. Independent modules for vertical or horizontal return configurations shall be available. Vertical return modules shall be available as a factory installed option. c. Damper blades shall be galvanized steel with composite gears. Plastic or composite blades on intake or return shall not be acceptable. d. Shall include all hardware and controls to provide free cooling with outdoor air when temperature and/or humidity are below setpoints. e. Shall be equipped with gear driven dampers for both the outdoor ventilation air and the return air for positive air stream control. f. Standard models shall be equipped with low- leakage dampers, not to exceed 2% leakage at 1 in. wg pres- sure differential. Economizers will come with Actuator and module that is tied to Simplicity SE (1.) Combined minimum and DCV maximum damper position potentiometers with compressor staging re-lay. (2.) Functions with solid state analog enthalpy or dry bulb changeover control sensing. (3.) Contain LED indicates for:when free cooling is availablewhen module is in DCV mode when exhaust fan contact is closed SUBMITTAL DATA For: Approval Order #: Date: 04/22/2016 Project: C 200 Williams Mech. Project #: EH04222016-01 Location: Purchaser: BILL WILLIAMS MECH. Submitter: ERIK YORK NW JCI Unitary Sales Tool 0.5.9.0 Information is subject to change without notice. Check local codes. Printed 04/22/2016 Date 04/22/2016 Project Name C 200 Williams Mech. Project Number EH04222016-01 Client / Purchaser BILL WILLIAMS MECH. WYORK Submittal Summary Page Qty Tag # Model # Description ZXG08E4B1AA1B111A2 7.5 Ton, York Direct Fit Single Packaged R-41 OA Air Conditioner, 11.0 EER / 11.5 IEER, Two Stage Cooling, Gas Heat, 180 Mbh Two Stage Input Medium Heat Aluminized Gas, 460-3-60 • Medium Static Belt Drive Blower • Copper Tube/Aluminum Fin Indoor Coil • Tube and Fin Condenser Coil • Simplicity® SE Controller including Discharge Air, Return Air, and Outdoor Air Temperature Sensors • Dry Bulb Economizer (Downflow only) (with Barometric Relief) with Economizer Fault Detection & Diagnostic 1 1 RC0457 Curb Rigid 14" Large Footprint Equipment start-up and commissioning by a factory trained technician is recommended. Contact -your supplying distributor or sales representative for additional information & guidance. Unitary Sales Tool 0.5.9.0 Information is subject to change without notice. Check local codes. Printed 04/22/2016 Prestige Single Package R -410A Air Conditioner Project Name: C 200 Williams Mech. Unit Model #: ZXG08E4B1AA1B111A2I Quantity: 1 System: ZXG08E461AA16111A2I t,00nng rerrormance Total capacity 94.9 MBH Sensible capacity 67.4 MBH Refrigerant type R-41 OA Efficiency (at ARI) 11.00 EER Integrated eff. (at ARI) 11.50 IEER Ambient DB temp. 95.0 °F Entering DB temp. 80.0 °F Entering WB temp. 67.0 °F Leaving DB temp. 59.2 °F Leaving WB temp. 57.0 °F Power input (w/o blower) 6.63 kW Sound power 84 dB(A) Gas Heating Performance Entering DB temp. 60 °F Heating output capacity (Max) 144 MBH Supply air 3000 CFM Heating input capacity (Max) 180 MBH Leaving DB temp. 104.4 °F Air temp. rise 44.4 °F SSE 80.0 % Stages 2 Supply Air Blower Performance Supply air 3000 CFM Ext. static pressure 0.6 IWG Addl. Unit Losses (Options/Accessories) 0.17 IWG Blower speed 815 RPM Max BHP of Motor (including service factor) 2.90 HP Duct location Bottom Actual required BHP 1.56 HP Power input 1.44 kW Elevation 0 ft. Drive type BELT Electrical Data Power supply 460-3-60 Unit min circuit ampacity 19.7 Amps Unit min over -current protection 20 Amps Unit max over -current protection 25 Amps Dimensions & Weight Hgt 41 in. Len 87 in. Wth 62 in. Weight with factory installed options 903 lbs. Clearances Right 18 in. Front 48 in. Back 36 in. T-- 79 in RnHnm 1 in I cft 19 in Note: Please refer to the tech guide for listed maximum static pressures ' &cap ts.. 7.5 Ton • All units are manufactured at an ISO 9001 registered facility and each rooftop is completely computer -run tested prior to shipment. Unit Features • Unit Cabinet Constructed of Powder Painted Steel, Certified At 1000 Hours Salt Spray Test (ASTM B-117 Standards) • Either supply and/or return can be field converted from vertical to horizontal configuration without cutting panels. • Full perimeter base rails with built in rigging capabilities • Scroll Compressors • Solid Core Liquid Line Filter Driers • Tube and Fin Condenser Coil • 180 Mbh Two Stage Input Medium Heat Aluminized Gas • Medium Static Belt Drive Blower • Unit Ships with 2" Throwaway Filters with a Standard Filter Rack that will Accept up to 4" Filters • Replacement Filters: 4 - (16" x 20"). Unit accepts 2" wide filter. • Single Point Power Connection • Short Circuit Current: 5kA RMS Symmetrical Standard Unit Controller: Simplicity SE Control Board • An Integrated Low -Ambient Control, Anti -Short Cycle Protection, Lead -Lag, Fan On and Fan off Delays, Low Voltage Protection, On -Board Diagnostic and Fault Code Display. Allows all units to operate in the cooling mode down to 0 °F outdoor ambient without additional components or intervention. • Safety Monitoring - Monitors the high and low-pressure switches, the freezestats, the gas valve, if applicable, and the temperature limit switch on gas and electric heat units. The unit control board will alarm on ignition failures, safety lockouts and repeated limit switch trips. BAS Controller • Simplicity SE Controller including Discharge Air, Return Air, and Outdoor Air Temperature Sensors Warranty • One (1) Year Limited Warranty on the Complete Unit • Five (5) Year Warranty - Compressors • Ten (10) Year Warranty - Aluminized Steel Tubular Heat Exchangers Unitary Sales Tool 0.5.9.0 Information is subject to change without notice. Check local codes. Printed 04/22/2016 WYORK Prestige Page: 4 Single Package R -410A Air Conditioner Project Name: C 200 Williams Mech. Unit Model #: ZXG08E4B1AA16111A2 Quantity: 1 System: ZXG08E4B1AA1B111A2 Factory Installed Options ZXG08E4B1 AA1 B111 A2 I Product Category: ZX York Dkect Fill."le Packaged R -410A Air Conditioner G Gas Heat Heat Type: 7.6 Too Nominal Cooling Capacity: Q$ 11 t9 B 114fs 1 JW0 Stage .c E 180 Mbh Two Stage Input Medium Heat Aluminized Heat Size: Gas voltage: 4 460-3-6Q B Airflow: Medium Static Belt Drive Blower Airflow Options: p � A Copper Tube/Aluminum Fin Indoor Coil Coil Options: Tube and Fin Condenser Coil e A Simptic" SE Controller including Discharge Air, Return Controls: Air, and Outdoor Air Temperature Sensors Sensor Options: B Dry Bulb Economizer (Downilow only) (with Barometric Economizer /Damper: Relief) with Economizes Fault Detection & Diagnostic Convenience Outlet: 1 Electrical Options: 1 Cabinet Options: 1 Special Options: A Product Generation: 2 Field Installed Accessories 1 RC0457 - Curb Rigid 14" Large Footprint (135.0 lbs) Unitary Sales Tool v1.5.9.0 Information is subject to change without notice. Check local codes. Printed 04/22/2016 U') � N � N r m � � � � � ry u •--I CL m m V Q J a Q Q W � I � W � ® G a W W 00 00 m v � Vml m � N IG^ X IGI^^ X N O LL N^ m O O N N O m �� m N N u i ry^ u 9u m m �.J� Z pp u u 3 OVTo 4) N O wH W S'%' NNHd C Z N Nco dW m m W C OED C6 .4= u u N vii • . 1- ¢ w �D .o • � mm r- d W OV w J V V ¢ ZO� H J zz�z .6 M O 0 3 ^ ^ d ¢ O ZZ C aO I0 O Hill1 ` r G � w O RYCL W 3 sI s Z V fA X ti K r Imp I I ¢ NZ ry J O d M 0 -77 W O N � � ry � N K h — _ I ggn M H n^ o1Eli mN u ^ V V d m Vl O O o= a 8- � o D n M llh v v=v m4 WV ¢ _ VC) ID u H H Z¢ S¢N G 20 8vind � oa rnm �--� V� 3 3 C¢ �--� r, m �--� m ZO�i~iS�HH ¢ H Z Z H W VI wl7 K •, Z V Vl d O� Z o ppN � � Z� H H O JoJmmmmm °.-1° �� z m 8>..--. S ¢v, � o z V u .N -i J v� LL H a W fv: 6 azm�mmrym Wd `a vi�ut� 'n m w -- mN in � r r �n o i --i o j Z w3'o"wv or J> 33 m QQ Vin U H H �n8oo•mo z f l7 P m m Z o z Z r 1- Vl w Vf -• H •- ox x LL l,7 L7 u d Q F- O D m E¢ 6F iU JtJ U ��b' r v,¢ W - 1 H Z Li K. inz Wozd -¢w 3 i- v � '- C •sr -•eV JLL¢oomz ••OwwK m1 -m 8 p oEWHrod¢ 00 �Ovtm 2 V FH d'10W OOvt H S C19nN^'m�--� �. a Icy 1 Z m m m m u V1 u '"MYORK Prestige Page: 6 Single Package R -410A Air Conditioner is Project Name: C 200 Williams Mech. Unit Model #: ZXG08E4B1AA1 B111A2 Quantity: 1 System: ZXGME461AA1B111M ry Horizontal Flow Dry Bulb Economizer Large Footprint Tall 82 Power Exhaust Vert Flow Small Footprint 55 Power Exhaust Vert Flow Large Footprint 75 Power Exhaust Horiz Flow Small Footprint 40 Power Exhaust Horiz Flow Large Footprint 80 Hail Guard Kit Small Short Factory Installed 18 Hail Guard Kit Small Tall Factory Installed 23 ry 44 uurn Ktgla 14--,5maii r-ootprint V4 Curb Rigid 14" Large Footprint 126 Curb Rigid 24" Small Footprint 148 Curb Rigid 24" Large Footprint 222 Unitary Sales Tool 0.5.9.0 Information is subject to change without notice. Check local codes. Printed 04/22/2016 12YORK Prestige Page: 7 Single Package R -410A Air Conditioner Project Name: C 200 Williams Mech. Unit Model #: ZXG08E4B1AA1B111A2 Quantity: 1 System: ZXG08E4B1AA1B111A2 1RC0457 Roof Curb 81.750 O.D. 78.250 I.D. 740.188 Q� 15.469 I.D. Qv RIGHT 34.313 �JQ 31.531 11.417 0 15.813 6.043 4.173 __ __ FRONT 24.813 84.00 O.D. X 81.746 1 RC0457 X= 14" Height 1 RC0459 X= 24" Height 53.50 O.D. 53.496 Notes: 1. Sides, ends, unit locator and cross support are 18-G90. Deck pans, R/A & S/A supports are 20-G90. 2. Full perimeter wood nailer. 3. Insulated deck pans. Unit Models used with 1 RC0457, 1 RC0459 Roof Curb ZX08 ZY07 ZX09 ZY08 ZX12 ZY09 ZX14 ZY12 Unitary Sales Tool 0.5.9.0 Information is subject to change without notice. Check local codes. Printed 04/22/2016 r!MYO1K Guide Specification for Page:8 Prestige 100 00 HEATING VENTILATING, AND AIR-CONDITIONING(HVAC) 23 06 00 Schedules for HVAC 23 06 80 Schedules for Decentralized HVAC Equipment 23 06 80. 13 Decentralized Unitary HVAC Equipment Schedule 23 06 80. 13.A Rooftop unit schedule 23 07 00 HVAC Insulation 23 07 16 HVAC Equipment Insulation 23 07 16. 13 Decentralized, Rooftop Units 23 07 16. 13.A Evaporator fan compartment 1. Interior cabinet surfaces shall be insulated with a minimum 1/2- in. thick, minimum 1 1/2 Ib density, flexible fiberglass insulation bonded with a phenolic binder, neoprene coated on the air side. 2. Insulation and adhesive shall meet NFPA 90A requirements for flame spread and smoke generation. 23 07 16. 13.6 Gas heat compartment 1. Aluminum foil -faced fiberglass insulation shall be used. 2. Insulation and adhesive shall meet NFPA 90A requirements for flame spread and smoke generation. 23 09 00 Instrumentation and Control for HVAC 23 09 13. 23 Sensors and Transmitters 23 09 13. 23.A Thermostats 1. Thermostat must: a. energize "G" when calling for fan only or continuous fan. b. have capability to energize 2 different stages of cooling, and 2 different stages of heating. c. include capability for occupancy scheduling. 23 09 23 Direct -digital Control system for HVAC 23 09 23. 13 Decentralized, Rooftop Units 23 09 23. 13.A Simplicity SE (Unit based microprocessor control) 1. Shall be ASHRAE 62-2001 compliant. 2. Shall include an integrated economizer controller to support an economizer with 4 to 20 mA actuator input. 3. Controller shall accept the following inputs: space temperature, setpoint adjustment, outdoor air temperature, indoor air quality, outdoor air quality, indoor relative humidity, compressor lockout, fire shutdown, enthalpy, fan status, remote time clock/door switch. 4. Shall accept a CO2 sensor in the conditioned space, and be Demand Control Ventilation ready. 5. Unit shall provide surge protection for the controller through a circuit breaker. 6. Shall have an LED display independently showing the status of activity on the communication bus, and processor operatlon. 7. Software upgrades will be accomplished by local download. Software upgrades through chip replacements are not allowed. 102= Guide Specification for Page:9 iMY01FK Prestige A. Unit shall be complete with self-contained low-voltage control circuit protected by a resettable circuit breaker on the 24-volt transformer side. B. Unit shall incorporate a lockout circuit which provides reset capability at the space thermostat or base unit should any of the following standard safety devices trip and shut off compressor: C. Loss-of-charge/Low-pressureswitch. D. High-pressure switch. E. Freeze-protection thermostat, evaporator coil. If any of the above safety devices trip, an LED (light-emitting diode) indicator shall flash a diagnostic code that indicates which safety switch has tripped. F. Unit shall incorporate "AUTO RESET' compressor over temperature, over current protection. G. Unit shall operate with conventional thermostat designs and have a low voltage terminal strip for easy hook-up. H. Unit control board shall have on -board diagnostics and fault code display. I. Standard controls shall include anti -short cycle and low voltage protection, and permit cooling operation down to 0 OF. J. Control board shall monitor each refrigerant safety switch independently. K. Control board shall retain last 5 fault codes in non-volatile memory, which will not be lost in the event of a power loss. 23 09 23. 13.13 RTU Open -multi -protocol, direct digital controller 1. Shall be ASHRAE 62-2001 compliant. 2. Shall include built-in protocol for BACNET , Modbus , and Johnson N2. 3. Shall allow access of up to .62 network variables (SNVT). Shall be compatible with all open controllers 4. Baud rate Controller shall be selectable using a dipswitch. 5. Shall have an LED display independently showing the status of serial communication, running, errors, power, all digital outputs, and all analog inputs. 6. Shall accept the following inputs: space temperature, setpoint adjustment, outdoor air temperature, indoor air quality, outdoor air quality, compressor lock- out, fire shutdown, enthalpy switch, and fan status/filter status/ humidity/ remote occupancy. 7. Software upgrades will be accomplished by either local or remote download. No software upgrades through chip replacements are allowed. 23 09 33 Electric and Electronic Control System for HVAC 23 09 33. 13 Decentralized, Rooftop Units 23 09 33. 13.A General 1. Shall be complete with self- contained low- voltage control circuit protected by a resettable circuit breaker on the 24-v transformer side. Transformer shall have 75VA capability. 2. Shall utilize color -coded wiring. 3. Shall include a central control terminal board to conveniently and safely provide connection points for vital control functions such as: smoke detectors, phase monitor, gas controller, economizer, thermostat, DDC control options, and low and high pressure switches. 4. The heat exchanger shall be controlled by an integrated gas controller (IGC) microprocessor. See heat exchanger section of this specification. 23 09 33. 23.13 Safeties Compressor over -temperature, over -current. High internal pressure differential. 2. Low-pressure switch. a. Units with 2 compressors shall have different sized connectors for the circuit 1 and circuit 2 low and high pressure switches. They shall physically prevent the cross- wiring of the safety switches between circuits 1 and 2. b. Low pressure switch shall use different color wire than the high pressure switch. The purpose is to assist the installer and service technician to correctly wire and or troubleshoot the rooftop unit. 3. High pressure switch. a. Units with 2roompressors shalt -have- different sized connectors for the circuit 1 and circuit 2 low—and high pressure switches. They shall physically prevent the cross -wiring of the safety switches between circuits 1 and 2. KwZllllllllllY01W Guide Specification for Page: 10 is Prestige b. High pressure switch shall use different color wire than the low pressure switch. The purpose is to assist the installer and service technician to correctly wire and or troubleshoot the rooftop unit. 4. Automatic reset,/motor thermal overload protector. 5. Heating section shall be provided with the following minimum protections: a. High-temperature limit switches. b. Induced draft motor speed sensor. c. Flame rollout switch. d. Flame proving controls 23 09 93 Sequence of Operations for HVAC Controls 23 09 93. 13 Decentralized, Rooftop Units 23 09 93. 13 INSERT SEQUENCE OF OPERATION 23 40 13 Panel Air Filters 23 40 13. 13 Decentralized, Rooftop Units 23 40 13. 13.A Standard filter section 1. Shall consist of factory -installed, low velocity, disposable 2" thick fiberglass filters of commercially available sizes. 2. Units can accept 2" or 4" filters and have a field convertible toolless 3. Filters shall be accessible through an access panel with toolless removal as described in the unit cabinet section of this specification (23 81 19.13.1-1). 23 81 19 Self -Contained Air Conditioners 23 81 19. 13 Small -Capacity Self -Contained Air Conditioners 23 81 19. 13.A General 1. Outdoor, rooftop mounted, electrically controlled, heating and cooling unit utilizing a fully hermetic scroll compressor(s) for cooling dutyand gas combustion for heating duty. 2. Factory assembled, single -piece heating and cooling rooftop unit. Contained within the unit enclosure shall be all factory wiring, piping, controls, and special features required prior to field start-up. 3. Unit shall use environmentally sound, R -410A refrigerant. 4. Unit shall be installed in accordance with the manufacturer's instructions. 5. Unit must be selected and installed in compliance with local, state, and federal codes. 23 81 19. 13.6 Quality Assurance 1. Unit meets ASHRAE 90.1 minimum efficiency requirements. 3. Unit shall be rated in accordance with AHRI Standards 210/240 and 340/360. 4. Unit shall be designed to conform to ASHRAE 15, 2001. 5. Unit shall be UL -tested and certified in accordance with ANSI Z21.47 Standards and UL -listed and certified under Canadian standards as a total package for safety requirements. 6. Insulation and adhesive shall meet NFPA 90A requirements for flame spread and smoke generation. 7. Unit casing shall be capable of withstanding 1000 -hour salt spray exposure per ASTM 13117 (scribed specimen). 8. Unit shall be designed in accordance with ISO 9001, and shall be manufactured in a facility registered by; ISO 9001. 9. Roof curb shall be designed to conform to NRCA Standards. 10. Unit shall be subjected to a completely automated run test on the assembly line. The data for each unit; will be stored at the factory, and must be available upon request. 11. Unit shall be designed in accordance with UL Standard 1995, including tested to withstand rain. 1.2.-U.nit shake tested to assurance level 1, ASTM D4169 to ensure shipping reliability. 'v13:`'High Efficient Motors listed shall meet `sectionr313 of the Energy Independence and Security Act of 2007-t(EISA T007). w1YORK Guide Specification for Page: 11 Prestige 23 81 19. 13.13 Delivery, Storage, and Handling 1. Unit shall be stored and handled per manufacturer's recommendations. 23 81 19. 13.E Project Conditions 1. As specified in the contract. 23 81 19. 131 Operating Characteristics 1. Unit shall be capable of starting and running at 125°F (52°C)ambient outdoor temperature, meeting maximum load criteria of AHRI Standard 210/240 or 340/360 at ± 10% voltage. 1. Compressor with standard controls shall be capable of operation down to 0°F (2°C), ambient outdoor temperatures.See' below for head pressure control package or winter start kit. 3. Unit shall discharge supply air vertically or horizontally as shown on contract drawings. 4. Unit shall be factory configured for vertical supply & return configurations. 5. Unit shall be field convertible from vertical to horizontal airflow on all models. 6. Unit shall be capable of mixed operation: vertical supply with horizontal return or horizontal supply with vertical return. 23 81 19. 13.G Electrical Requirements 1. Main power supply voltage, phase, and frequency must match those required by the manufacturer. 23 81 19. 13.H Unit Cabinet 1. Unit cabinet shall be constructed of galvanized steel with exterior surfaces coated with a non -chalking, powder paint finish, certified at 1000 hour salt spray test per ASTM -6117 standards. 2. Evaporator fan compartment interior cabinet insulation shall conform to AHRI Standards 210/240 or 340/360 minimum exterior sweat criteria. Interior surfaces shall be insulated with a minimum 1/2- in. thick, 1 Ib density, flexible fiberglass insulation, neoprene coated on the air side. Aluminum foil- faced fiberglass insulation shall be used in the gas heat compartment. Fan shall be a belt drive assembly and include an adjustable pitch motor pulley. Fan wheel shall be double inlet type with forward curve blades, dynamically balanced to operate smoothly throughout the entire range of operation. Airflow design shall be constant volume. Bearings shall be sealed and permanently lubricated for longer life and no maintenance. Entire blower assembly and motor shall be slide out design. 3. Condenser Fan Assembly: The outdoor fans shall be of the direct drive type, discharge air vertically, have aluminum blades riveted to corrosion resistant steel spider brackets and shall be dynamically balanced for smooth operation. The outdoor fan motors shall have permanently lubricated bearings internally protected against overload conditions and staged independently. A cleaning window shall be provided on two sides of the units for coil cleaning. 4. Base of unit shall have a minimum of four locations for thru-the-base gas and electrical connections (factory installed or field installed), standard. 5. Base Rail a. Unit shall have base rails on a minimum of 4 sides. b. Holes shall be provided in the base rails for rigging shackles to facilitate maneuvering and overhead rigging. c. Holes shall be provided in the base rail for moving the rooftop by fork truck.. d. Base rail shall be a minimum of 16 gauge thickness. 6. Condensate pan and connections a. Shall be an internally sloped condensate drain pan made of a non -corrosive material. b. Shall comply with ASHRAE Standard 62. c. Shall use a 3/4" - 14 NPT drain connection, possible either through the bottom or side of the drain pan. Connection shall be made per manufacturer's recommendations. 7. Top panel a. Shall be a single piece top panel. 8. Gas Connections a. All gas piping connecting to unit gas valve shall enter the unit cabinet at a single location on side of unit b. Thru-the-base capability (1.) Standard unit shall have a thru-the-base gas- line location using a raised, embossed portion of the unit basepan. (2.) Optional, factory- approved, water- tight connection method must be used for thru-the-base gas connections. (3.) No basepan penetration, other than those authorized by the manufacturer, is'permitted. go Guide Specification for Page: 12 Prestige 9. Electrical Connections a. All unit power wiring shall enter unit cabinet at a single, factory -prepared, knockout location. b. Thru-the-base capability. (1.) Standard unit shall have a thru-the-base electrical location(s) using a raised, embossed portion of the unit basepan. (2.) Optional, factory- approved, water -tight connection method must be used for thru-the-base electrical connections. (3.) No basepan penetration, other than those authorized by the manufacturer, is permitted. 10. Component access panels (standard) a. Cabinet panels shall be easily removable for servicing. b. Unit shall have one factory installed, toolless, removable, filter access panel. c. Panels covering control box, indoor fan, indoor fan motor, gas components(where applicable), and compressors shall have a molded composite handles. d. Handles shall be UV modified, composite. They shall be permanently attached, and recessed into the panel. e. Screws on the vertical portion of all removable access panel shall engage into heat resistant, molded composite collars. f. Collars shall be removable and easily replaceable using manufacturer recommended parts. 23 81 19. 13.1 Gas Heat 1. General a. Heat exchanger shall be an induced draft design. Positive pressure heat exchanger designs shall not be allowed. b. Shall incorporate a direct- spark ignition system and redundant main gas valve. c. Gas supply pressure at the inlet to the rooftop unit gas valve must match that required by the manufacturer. 2. The heat exchanger shall be controlled by an integrated gas controller (IGC) microprocessor. a. IGC board shall notify users of fault using an LED (light -emitting diode). b. The LED shall be visible without removing the control box access panel. c. IGC board shall contain algorithms that modify evaporator -fan operation to prevent future cycling on high temperature limit switch. d. Unit shall be equipped with anti -cycle protection with one short cycle on unit flame rollout switch or 4 continuous short cycles on the high temperature limit switch. Fault indication shall be made using an LED. 3. Standard Heat Exchanger construction a. Heat exchanger shall be of the tubular -section type constructed of a minimum of 20 -gauge steel coated with a nominal 1.2 mil aluminum -silicone alloy for corrosion resistance. b. Burners shall be of the in -shot type constructed of aluminum -coated steel. c. Burners shall incorporate orifices for rated heat output up to 2000 ft (610m) elevation. Additional accessory kits may be required for applications above 2000 ft (610m) elevation, depending on local gas supply conditions. d. Each heat exchanger tube shall contain multiple dimples for increased heating effectiveness. 6. Induced draft combustion motor and blower a. Shall be a direct -drive, single inlet, forward -curved centrifugal type. b. Shall be made from steel with a corrosion -resistant finish. c. Shall have permanently lubricated sealed bearings. d. Shall have inherent thermal overload protection. e. Shall have an automatic reset feature. 23 81 19. 13.J Coils 1. Standard Aluminum Fin/Copper Tube Coils a. Standard evaporator and condenser coils shall have aluminum lanced plate fins mechanically bonded to seamless internally grooved copper tubes with all joints brazed. b. Evaporator coils shall be leak tested to 150 psig, pressure tested to 450 psig, and qualified to UL 1995 burst test at 1775 psig. c. Condenser coils shatl be leak tested ta:1`50`psig, pressure tested to 650 psig, and qualified to UL 1995 burn test at 1980 psig. IAYORK Guide Specification for Page: 13 Prestige 23 81 19. 13.K Refrigerant Components 1. Refrigerant circuit shall include the following control, safety, and maintenance features a. Thermostatic Expansion Valve (TXV) shall help provide optimum performance across the entire operating range. Shall contain removable power element to allow change out of power element and bulb without removing the valve body.(Orifice on 3-5 Ton Units) b. Refrigerant filter drier - Solid core design. c. Service gauge connections on suction and discharge lines. d. Pressure gauge access through a specially designed access port in the top panel of the unit. 2. There shall be gauge line access port in the skin of the rooftop, covered by a black, removable plug. a. The plug shall be easy to remove and replace. b. When the plug is removed, the gauge access port shall enable maintenance personnel to route their pressure gauge lines. c. This gauge access port shall facilitate correct and accurate condenser pressure readings by enabling the reading with the compressor access panel on. d. The plug shall be made of a leak proof, UV- resistant, composite material. 3. Compressors a. Unit shall use fully hermetic, scroll compressor for each independent refrigeration circuit. b. Compressor motors shall be cooled by refrigerant gas passing through motor windings. c. Compressors shall be internally protected from high discharge temperature conditions. d. Compressors shall be protected from an over -temperature and over -amperage conditions by an internal, motor overload device. e. Compressor shall be factory mounted on rubber grommets. f. Compressor motors shall have internal line break thermal, current overload and high pressure differential protection. g. Crankcase heaters shall not be required for normal operating range, unless provided by the factory. 23 81 19. 131 Filter Section 1. Filters access is specified in the unit cabinet section of this specification. 2. Shall consist of factory -installed, low velocity, throw -away 2" thick fiberglass filters. 3. Units can accept 2" or 4" filters and have a field convertible toolless 23 81 19. 13.M Evaporator Fan and Motor 1. Evaporator fan motor a. Shall have permanently lubricated bearings. b. Shall have inherent automatic -reset thermal overload protection or circuit breaker. 3. Belt -driven Evaporator Fan a. Belt drive shall include an adjustable -pitch motor pulley. b. Shall use sealed, permanently lubricated ball-bearing type. c. Blower fan shall be double -inlet type with forward -curved blades. d. Shall be constructed from steel with a corrosion resistant finish and dynamically balanced. 23 81 19. 13.N Condenser Fans and Motors The outdoor fans shall be of the direct drive type, discharge air vertically, have aluminum blades riveted to corrosion resistant steel spider brackets and shall be dynamically balanced for smooth operation. The outdoor fan motors shall have permanently lubricated bearings internally protected against overload conditions and staged independently. A cleaning window shall be provided on two sides of the units for coil cleaning. 1. Condenser fan motors a. Shall be a totally enclosed motor. b. Shall use permanently lubricated bearings. c. Shall have inherent thermal overload protection with an automatic reset feature. _._ _A.- <Aii'models.shall use a shaft -down design except shaft -up pn ZX14 &J ZY12 size with rain shield. 2. Condenser Fans I 10 WYORK Guide Specification for Page: 14 Prestige a. Shall be a direct -driven propeller type fan. b. Shall have aluminum blades riveted to corrosion -resistant steel spiders and shall be dynamically balanced. 23 81 19. 13.0 Special Features Options and Accessories 3. Standard Integrated Economizers: a. Integrated, gear -driven opposing modulating blade design type capable of simultaneous economizer and compressor operation. b. Independent modules for vertical or horizontal return configurations shall be available. Vertical return modules shall be available as a factory installed option. c. Damper blades shall be galvanized steel with composite gears. Plastic or composite blades on intake or return shall not be acceptable. d. Shall include all hardware and controls to provide free cooling with outdoor air when temperature and/or humidity are below setpoints. e. Shall be equipped with gear driven dampers for both the outdoor ventilation air and the return air for positive air stream control. f. Standard models shall be equipped with low- leakage dampers, not to exceed 2% leakage at 1 in. wg pres- sure differential. Economizers will come with Actuator and module that is tied to Simplicity SE (1.) Combined minimum and DCV maximum damper position potentiometers with compressor staging re-lay. (2.) Functions with solid state analog enthalpy or dry bulb changeover control sensing. (3.) Contain LED indicates for:when free cooling is availablewhen module is in DCV mode when exhaust fan contact is closed PERMIT COORD COPY PLAN REVIEW/ROUTING SLIP PERMIT NUMBER: M16-0117 DATE: 07/12/16 PROJECT NAME: VACANT SPACE SITE ADDRESS: 14520 INTERURBAN AVE S - SUITE 200 X Original Plan Submittal Revision # before Permit Issued Response to Correction Letter # Revision # after Permit Issued DEPARTMENTS: I "V L -7,114—[p �Q Building Division a AiA AWL -7-)0--1 � Fire Prevention a Planning Division ❑ Public Works ❑ Structural ❑ Permit Coordinator PRELIMINARY REVIEW: DATE: 07/14/16 Not Applicable ❑ Structural Review Required ❑ (no approval/review required) REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: DUE DATE: 08/1.1/16 Approved ❑ Approved with Conditions Corrections Required ❑ Denied ❑ (corrections entered in Reviews) (ie: Zoning Issues) Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: 12/18/2013 WILLIAMS MECHANICAL INC Home Ispanol Contact Safety & Health Claims & Insurance inWashington State Department of Labor & Industries Page 1 of 2 Search L&I� A-ZIndex Help M% L&I Workplace Rights Trades & Licensing WILLIAMS MECHANICAL INC $1,000,000.00 Owner or tradesperson 3903 SMITH AVE Principals EVERETT, WA 98201-4549 WILLIM1088PA 425-303-0828 WILLIAMS, BRADLEY PATRICK, PRESIDENT SNOHOMISH County WILLIAMS, DEBORAH KAY, SECRETARY Expiration date WILLIAMS, DEBORAH KAY, TREASURER 09130/2017 WILLIAMS, DEBORAH KAY, AGENT $12,000.00 ZUCCARINI, MICHAEL J, AGENT (End: 01/01/1980) Doing business as WILLIAMS MECHANICAL INC WA UBI No. Business type 601 413 863 Corporation License Verify the contractor's active registration / license / certification (depending on trade) and any past violations. Construction Contractor Active. ...................................................... . Meets current requirements. License specialties $1,000,000.00 GENERAL License no. WILLIM1088PA Effective date Effective — expiration 09/30/2015 10101/1992-10101/2017 Expiration date Bond 09130/2017 Merchants Bonding Co (Mutual) $12,000.00 Bond account no. WA33987 Received by L&I Effective date 0912312014 10/0112014 Expiration date Until Canceled Bond history Insurance Allied Property & Cas Ins Co $1,000,000.00 Policy no. ACP3007325217 Received by L&I Effective date 07/26/2016 09/30/2015 Expiration date 09130/2017 Insurance history Savings https:Hsecure.Ini.wa.gov/verify/Detail.aspx?UBI=601413 863 &LIC=WILLIMI088PA&SAW= 8/1/2016 ,` .. T b i._ . NOTES ■ 1. POST BUILDING ADDRESS SIGN ON FRONT OF BUILDING AS REQUIRED BY BUILDING OFFICIAL. COORDINATE WITH ARCHITECT. 2. CONTRACTOR IS SOLELY AND COMPLETELY RESPONSIBLE FOR CONDITIONS OF THE JOB SITE, INCLUDING SAFETY, PROTECTION OF PROPERTY AND THE LIKE DURING THE PERFORMANCE OF THE WORK. 3. THE CONTRACTOR IS REQUIRED TO COMPLY WITH ALL APPLICABLE REGULATIONS AND CODES OF THE GOVERNING AUTHORITIES AND OWNERS. 4. PROVIDE METHODS, MEANS AND FACILITIES REQUIRED TO PREVENT CONTAMINATION OF SOIL, WATER OR ATMOSPHERE. 5. INSURE MINIMUM INTERFERENCE WITH EXISTING ROADS, STREETS, SIDEWALKS, PARKING FACILITIES AND ADJACENT FACILITIES. DO NOT CLOSE OR OBSTRUCT WITHOUT PRIOR APPROVAL. 6. ALL SALVAGE WILL BECOME THE PROPERTY OF THE CONTRACTOR, UNLESS NOTED OTHERWISE (UNO). PROMPTLY REMOVE FROM SITE AND LEGALLY DISPOSE OF ALL SAID MATERIAL AT CONTRACTOR'S EXPENSE. 7. DIMENSIONS ARE TO: - FACE OF MASONRY OR CONCRETE, CENTER LINE OF COLUMNS, FACE OF STUD, OR FACE OF MULLION UNLESS NOTED OTHERWISE. - DIMENSIONS INDICATED CLEAR (CLR) ARE TO FINISH FACE. - DIMENSIONS TO DOOR AND WINDOW OPENINGS ARE ROUGH MASONRY OPENINGS UNO. - ALL MASONRY DIMENSIONS ARE NOMINAL. 8. SCRIBE GYPSUM BOARD OF WALLS AND PARTITIONS TO IRREGULARITIES OF STRUCTURE OR DECK ABOVE AND SEAL TIGHTLY AROUND ALL PENETRATIONS. 9. IT IS THE RESPONSIBILITY OF THE CONTRACTOR TO COORDINATE WITH THE OWNER'S WORK AND/OR SUPPLIED ITEMS THAT ARE "FURNISHED BY THE OWNER AND INSTALLED BY THE CONTRACTOR" OR "NOT IN CONTRACT" (NIC), BUT ARE ATTACHED TO CONTRACTOR'S WORK. 10. ALL RAMPS TO HAVE MAXIMUM 1:12 SLOPE. RAMPS WITH SLOPE OF 1:20 OR GREATER TO HAVE HANDRAILS PER WASHINGTON STATE HANDICAP CODE. 11. ALL STAIRS TO HAVE MINIMUM 11" TREADS AND MAXIMUM 7" RISERS, UNO. 12. MINIMUM ROOF SLOPE SHALL BE 1/4"=1'-0". _ 13. CONTRACTOR IS RESPONSIBLE FOR REVIEWING THE DRAWINGS AND SPECIFICATIONS AND WITH THE NOTIFICATION OF THE ARCHITECT OF ANY DISCREPENCIES WITHIN THE DOCUMENTS AND THE SCOPE OF WORK. CONTRACTOR IS RESPONSIBLE TO COORDINATE ANY AND ALL REVISIONS TO THE DRAWINGS. 14. FIRE EXTINGUISHERS TO BE LOCATED PER FIRE MARSHALL'S DIRECTION. AS REQ'D. 15. ALL ROUGH -INS SHALL BE APPROVED PRIOR TO FRAMING INSPECTION. 16. PROVIDE ONE 2A-10BC FIRE EXTINGUISHER PER 3,000 SQ.FT. OR EACH 75' OF TRAVEL DISTANCE, AS REQUIRED BY FIRE MARSHALL. 17. EXIT LIGHTING SHALL BE PROVIDED WHEN TWO EXITS ARE REQUIRED. THE EMERGENCY SYSTEM SHALL BE SUPPLIED BY A SEPARATE SOURCE OF POWER AND HAVE AN EMERGENCY BACK UP SYSTEM. EXITS SHALL BE ILLUMINATED AT ANY TIME THE BUILDING IS OCCUPIED WITH EMERGENCY LIGHTING HAVING THE INTENSITY OF NOT LESS THAN 1 FOOT CANDLE AT FLOOR LEVEL. IBC SECTION 1006.3. 18. EXIT DOORS SHALL BE OPENABLE FROM THE INSIDE WITHOUT THE USE OF A KEY OR ANY SPECIAL KNOWLEDGE OR EFFORT. 19. EXCEPTION: KEY -LOCKING HARDWARE MAY BE USED ON THE MAIN EXIT WHEN THE MAIN EXIT CONSISTS OF A SINGLE DOOR OR PAIR OF DOORS IF THERE IS A READILY VISIBLE, DURABLE SIGN ON OR ADJACENT TO THE DOOR STATING "THIS DOOR TO REMAIN UNLOCKED DURING BUSINESS HOURS." THE SIGN SHALL BE IN LETTERS NO LESS THAN 1 INCH HIGH ON CONTRASTING BACKGROUND. WHEN LOCKED, THE SINGLE DOOR OR BOTH LEAVES OF A PAIR OF DOORS MUST BE FREE TO SWING WITHOUT OPERATION OF ANY LATCHING DEVICE. 20. TRASH DUMPSTERS AND COMPACTORS SHALL BE PROVIDED WITH RUBBER WHEELS N.I.C. 21. EXTERIOR JOINTS AROUND WINDOWS AND DOOR FRAMES, OPENINGS BETWEEN WALLS AND FOUNDATIONS, BETWEEN WALLS AND ROOF AND WALL PANELS; OPENINGS AT PENETRATIONS OF UTILITY SERVICES THROUGH WALLS, FLOORS AND ROOFS; AND ALL OTHER OPENINGS IN THE BUILDING ENVELOPE SHALL BE SEALED, CAULKED, GASKETED OR WEATHERSTRIPPED TO LIMIT AIR LEAKAGE. t-{�pir Y F� % 1 1 k C ""�a, 1, s L� 22. BUILDING INSULATION SHALL BE PROVIDED AS INDICATED IN DWGS. W/ R VALUES PER ENERGY CALCULATIONS. 23. EVERY HANDICAPPED PARKING SPACE SHALL BE IDENTIFIED BY A SIGN CENTERED ON THE STALL. THE BOTTOM OF THE SIGN NEEDS TO BE 60 INCHES ABOVE THE PARKING SURFACE, AT THE HEAD OF THE PARKING SPACE. THE SIGN SHALL INCLUDE THE INTERNATIONAL SYMBOL OF ACCESS AND THE PHRASE "STATE DISABLED PARKING PERMIT REQUIRED". PROVISION UNDER SITE DEVELOPMENT PERMIT. 24. THIS DRAWING IS AN INSTRUMENT OF SERVICE ONLY. THE COPYRIGHT TO THIS DRAWING BELONGS TO THE ARCHITECT. NO PERSON MAY USE THIS DRAWING FOR ANY PURPOSE OTHER THAN THE INTENDED ORIGINAL PURPOSE FOR THE ORIGINAL CLIENT. THIS DRAWING MAY NOT BE REPRODUCED IN WHOLE OR IN PART, IN ANY MANNER OR STORED IN ANY FORM FOR REPRODUCTION WITHOUT THE EXPRESS PERMISSION OF THE ARCHITECT. NO VALUE SHOULD BE SCALED AND ALL VALUES SHOULD BE CHECKED AGAINST FIELD VALUES AND/OR CHECKED WITH THE ARCHITECT. IF ANY VALUES IS FOUND TO BE INCORRECT OR INVALID, THEN IT IS THE RESPONSIBILITY OF THE USER TO INFORM THE ARCHITECT AND TO OBTAIN THE CORRECT VALUE FROM THE ARCHITECT PRIOR TO ACTING. 25. PER W.S.E.C. SECTION 1416.3.2 ACCEPTANCE: FINAL CERTIFICATE OF OCCUPANCY SHALL NOT BE ISSUED UNTIL THE BUILDING OFFICIAL DETERMINES THAT THE PRELIMINARY COMMISSIONING REPORT REQUIRED BY SECTION 1416.2.6.2 HAS BEEN COMPLETED. IF THIS DRAWING WAS CREATED AND/OR TRANSFERRED ON ELECTRONIC MEDIA TO ANY OTHER PERSON OR BODY, THEN THE USER SHOULD BE AWARE THAT THE DRAWING MAY HAVE BEEN ALTERED AFTER ISSUE BY THE ARCHITECT. THE ONLY ORIGINAL OF THIS DRAWING RESIDES IN THE FILES OF THE ARCHITECT, AND SHALL TAKE PRECEDENT OVER ALL COPIES, PAPER OR ELECTRONIC. THIS DRAWING MAY CONTAIN MATERIAL WHICH WAS PROVIDED FOR INFORMATION ONLY TO THE ARCHITECT BY THE CLIENT OR CLIENTS CONSULTANTS. THE ARCHITECT ACCEPTS NO RESPONSIBILITY FOR THE ACCURACY OR THE COMPLETENESS OF THIS MATERIAL. IF VALUES IN THE DRAWING ARE FOUND TO BE CRITICAL TO THE SCOPE OF WORK, THEN THE USER IS ADVISED TO REFER BACK TO THE ORIGINAL MATERIALS IN THE HANDS OF THE CLIENT. FIRE CODE FIRE ADDRESS: APPROVED ADDRESS SHALL BE PROVIDED FOR ALL BUILDINGS IN SUCH A POSITION AS TO BE PLAINLY VISIBLE AND LEGIBLE FROM THE STREET OR ROAD FRONTING THE PROPERTY. FIRE ADDRESS/TEMPORARY: TEMPORARY ADDRESSING IS REQUIRED DURING CONSTRUCTION SHALL BE VISIBLE FROM THE STREET. FIRE KNOX BOX: IF THE BUILDING OR SUITE HAS A FIRE PROTECTION SYSTEM, A KNOX BOX SHALL BE INSTALLED IN AN APPROVED LOCATION AND ALL REQUIRED KEYS SHALL BE ON SITE FOR LOCK UP PRIOR TO BUILDING FIRE FINAL. FIRE OCCUPANT LOAD: OCCUPANT LOAD SHALL BE POSTED IN A CONSPICUOUS LOCATION AT OR AROUND THE MAIN EXIT. PORTABLE FIRE EXTINGUISHER: PORTABLE FIRE EXTINGUISHER WILL BE REQUIRED DURING CONSTRUCTION AND INSTALLED FOR FINAL INSPECTION. CLASS 2A 106C TYPE IS/ARE REQUIRED. PLEASE MOUNT THE EXTINGUISHER(S) IN A CONSPICUOUS LOCATION APPROVED BY THE FIRE DEPARTMENT AND LOCATE THE EXTINGUISHER(S) SO THAT THE TRAVEL DISTANCE FROM ANY POINT IN SPACE DOES NOT EXCEED 75 FEET TO AN EXTINGUISHER. (THE DISTANCE BETWEEN EXTINGUISHERS CAN BE 150 FEET), FIRE SPRINKLER SYSTEM: STRUCTURE SHALL HAVE A FIRE SPRINKLER INSTALLED PER NFPA AND EASTSIDE FIRE & RESCUE REQUIREMENTS. SUBMIT FOR A FIRE PERMIT. AC ACCOUSTIC FIXT FIXTURE OD OUTSIDE DIAMETER EXISTING BUILDING- NO CHANGES TO BUILDING ENVELOPE. ADD ADDENDUM FL FLASHING OFS OVERFLOW Type VB SPPINKLERED ADD'N ADDITION FLR FLOOR Wind Exposure / Seismic Zone SCUPPER Proposed Building Uses/Exits Required ABC AGGREGATE BASE F.D. FLOOR DRAIN OFD OVERFLOW DRAIN COURSE FLUOR FLUORESCENT AGG AGGREGATE FTG FOOTING PARA PARAPET A/C AIR CONDITIONING FND FOUNDATION PTD PAINTED AL ALUMINIUM FR FRAME PG PAGE ALT ALTERNATE FHC FIRE HOSE CABINET PR PAIR AB ANCHOR BOLT FV FIELD VERIFY PNL PANEL ABV ABOVE PTN PARTITION & AND GA GAUGE d PENNY ARCH ARCHITECT GI GALVANIZED IRON PL PLATE ASP ASPHALT GL GLASS PLBG PLUMBING GD GRADE PLYWD PLYWOOD BSMT BASEMENT GYP GYPSUM PT POINT BM BEAM GWB GYPSUM WALL PSI POUNDS PER BEL BELOW BOARD SQUARE INCH B.M. BENCHMARK GRND GROUND PSF POUNDS PER BLKG BLOCKING SQUARE FOOT BD BOARD HR HANDRAIL PC PRECAST BO BOTTOM OF HDN HARDENER PL PROPERTY LINE BLDG BUILDING HDW HARDWARE HDWD HARDWOOD R RADIUS CABT CABINET HTR HEATER REG REGISTER C.I.P. CAST IN PLACE HT HEIGHT REQ'D REQUIRED C.B. CATCH BASIN HP HIGH POINT REV REVISION CLG CEILING H.M. HOLLOW METAL RD ROOF DRAIN CEM CEMENT HORIZ HORIZONTAL RFG ROOFING CG CENTIGRAM HB HOSE BIB RM ROOM CL CENTER LINE HW HOT WATER RGH ROUGH CER CERAMIC RD ROUND C.T. CERAMIC TILE IN INCH CHAN. CHANNEL ID INSIDE DIAMETER SCR SCREW CLR CLEAR INSUL INSULATION SECT SECTION C.O. CLEAN OUT INT INTERIOR SEL SELECT CLOS CLOSET INV INVERT SHT SHEET COL COLUMN SDG SIDING CONIC CONCRETE JAN JANITOR Sim SIMILAR CONN CONNECTION JT JOINT SLDG SLIDING SYMB"OLS CONST CONSTRUCTION JST JOIST SM SMOOTH CJ. CONTROL JOINT SPEC SPECIFICATION _ CONSTRUCTION JOINT KP KICK PLATE SPL SPLASH CONT CONTINUOUS SQ SQUARE GRID LINE X - CONTR CONTRACTOR LAM LAMINATED STD STANDARD COR'G CORRUGATED LDG LANDING SS STAINLESS STEEL CTR COUNTER LAV LAVATORY STRUC STRUCTURE now CTSK COUNTERSINK LG LENGTH SUSP SUSPENDED NAML CMU CONCRETE LOC LOCATION SWBD SWITCHBOARD DRAWING TITLE MASONRY UNIT LT LIGHT SCALE CMS CORRUGATED LWC LIGHT WEIGHT TC TOP OF CURB METAL SIDING CONCRETE TG TEMPERED GLASS LVR LOUVER T.O. TOP OFX SHEET # D. A. DAMP PROOFING LOC LOCATION T.S. TUBE STEEL DIAG DIAGONAL TSD TOP OF STEEL EXTERIOR X INTERIOR X X. X DIAM DIAMETER MO MASONRY OPENING DECK ELEVATION KEY A4.X ELEVATION KEY X DIM DIMENSION MATL MATERIAL TYP TYPICAL DISP DISPENSER MFR MANUFACTURER DWL DOWEL MAX MAXIMUM U.N.O. UNLESS NOTEDX DN DOWN MCJ MAS CNTRL JNT OTHERWISE DETAIL X ENLARGED AX.X D. S. DOWNSPOUT MECH MECHANICAL U.N.P. UNDER SEPARATE REFERENCE AX.X PLAN DWG DRAWING MET METAL PERMIT MTL METAL X EA EACH ML METAL LATH V VENT EL ELECTRIC MID MIDWAY / MIDDLE VERT VERTICAL AX.X EDF ELECTRIC DRINKING MIN MINIMUM VEST VESTIBULE FOUNTAIN MLDG MOULDING VCT VINYL COMPOSITION c ELEV ELEVATION MULL MULLION TILE EQ EQUAL NG NATURAL GRADE WWM WELDED WIRE MESH WALL SECTION X BUILDING X X EQUIP EQUIPMENT A5.X SECTION A4.0 A4.0 EXH EXHAUST NOM NOMINAL WC WATER CLOSET EXP EXPANSION N.I.C. NOT IN CONTRACT WH WATER HEATER EJ EXPANSION JOINT 0/ OVER WF WIDE FLANGE Z EXIST EXISTING OBS OBSERVE W/ WITH DOOR NUMBER(WINDOW TYPE 101 OH OC ON CENTER W/0 WITHOUT FT FEET OPG OPENING FIN FINISH OA OVERALL WALL TYPE �--- FINISH TAG X -X L I I N.T.S. Building Identifier: C Applicable Code: IBC 2012 Edition Site Area: 3.3 ACRES Zoning: C/LI Occupancy Groups: B Mixed Use Class Non Separated Uses Construction: Type VB SPPINKLERED Height 32 ft+/- (highest point) Number of Stories Two Wind Exposure / Seismic Zone NIA, Existing Structure Proposed Building Uses/Exits Required HVAC NOTES Scope of work is for HVAC mechanical only including one package unit RTU -1. Other information on these plans is for reference only. All duct fabrication and insulations per SMACNNA and WSEC standards. System will be commissioned per 2012 WSEC C408. See sheet M-3 for RTU -1 specifications. A receptacle outlet will be provided near by per N"IFPA 70 Gas piping and low voltage will be submitted with other permit ap601 plications. RLECopy permflt No. _M,1 62,_- 0-1.) -7- F:� T "V18�id FtPpr©v8I 1s st1*ct to errors and omi3Sio fs. Appi ov I Of 00nsiP' iaiiondocuments does not author;=8 t10 visa!;; !ik--�,0 of any adopted codo or ordinance. Reipi of app; oiled ieid Cc py and conditions is acknowledged: 1311 Y: --, Date: City Of Tula BUILDING DIVISIOI Ui TE PEP -MIT ED Pi 7 F019: DMechanical M'66'1111Cat [j Aumbing ►s Piping Lite Of Tukwila ''e' �`"'"� DIVI.S►nni r� t1 ^ s� } -all b3mldo 11ENIISIONS }/1 h eop of w,07% 11, prior approval of Building DhAsion. r,gL-ire a ne%v plan submittal and may in ,,Llde adv;tional plan review fees. REVIEWl ED FOR CODE COMPLIANCE APPROVED JUL 2 G 2016 Ct I? Of TU11 IIa BU1L0IN1Q (0tq _ RECIADV=D CI TURWiLA OF JUL 12 2016 PERMIT CENTER Area Occ. Load Factor Occ. Load Warehouse 3,70C 500 7 Office 1,01E 100 10 Total 1st floor 4,71E 27 18 HVAC NOTES Scope of work is for HVAC mechanical only including one package unit RTU -1. Other information on these plans is for reference only. All duct fabrication and insulations per SMACNNA and WSEC standards. System will be commissioned per 2012 WSEC C408. See sheet M-3 for RTU -1 specifications. A receptacle outlet will be provided near by per N"IFPA 70 Gas piping and low voltage will be submitted with other permit ap601 plications. RLECopy permflt No. _M,1 62,_- 0-1.) -7- F:� T "V18�id FtPpr©v8I 1s st1*ct to errors and omi3Sio fs. Appi ov I Of 00nsiP' iaiiondocuments does not author;=8 t10 visa!;; !ik--�,0 of any adopted codo or ordinance. Reipi of app; oiled ieid Cc py and conditions is acknowledged: 1311 Y: --, Date: City Of Tula BUILDING DIVISIOI Ui TE PEP -MIT ED Pi 7 F019: DMechanical M'66'1111Cat [j Aumbing ►s Piping Lite Of Tukwila ''e' �`"'"� DIVI.S►nni r� t1 ^ s� } -all b3mldo 11ENIISIONS }/1 h eop of w,07% 11, prior approval of Building DhAsion. r,gL-ire a ne%v plan submittal and may in ,,Llde adv;tional plan review fees. REVIEWl ED FOR CODE COMPLIANCE APPROVED JUL 2 G 2016 Ct I? Of TU11 IIa BU1L0IN1Q (0tq _ RECIADV=D CI TURWiLA OF JUL 12 2016 PERMIT CENTER J Co Office 864 100 9 Warehouse Storage 146 300 1 Total Mezzanine 1,01C 10 TOTAL 5.726 27 HVAC NOTES Scope of work is for HVAC mechanical only including one package unit RTU -1. Other information on these plans is for reference only. All duct fabrication and insulations per SMACNNA and WSEC standards. System will be commissioned per 2012 WSEC C408. See sheet M-3 for RTU -1 specifications. A receptacle outlet will be provided near by per N"IFPA 70 Gas piping and low voltage will be submitted with other permit ap601 plications. RLECopy permflt No. _M,1 62,_- 0-1.) -7- F:� T "V18�id FtPpr©v8I 1s st1*ct to errors and omi3Sio fs. Appi ov I Of 00nsiP' iaiiondocuments does not author;=8 t10 visa!;; !ik--�,0 of any adopted codo or ordinance. Reipi of app; oiled ieid Cc py and conditions is acknowledged: 1311 Y: --, Date: City Of Tula BUILDING DIVISIOI Ui TE PEP -MIT ED Pi 7 F019: DMechanical M'66'1111Cat [j Aumbing ►s Piping Lite Of Tukwila ''e' �`"'"� DIVI.S►nni r� t1 ^ s� } -all b3mldo 11ENIISIONS }/1 h eop of w,07% 11, prior approval of Building DhAsion. r,gL-ire a ne%v plan submittal and may in ,,Llde adv;tional plan review fees. REVIEWl ED FOR CODE COMPLIANCE APPROVED JUL 2 G 2016 Ct I? Of TU11 IIa BU1L0IN1Q (0tq _ RECIADV=D CI TURWiLA OF JUL 12 2016 PERMIT CENTER ,sob Humber. 1005 Date: LARCH 02, 2016 Principal In Charge: VWAM RRIM Project Manager VMD KHASTDU Drawn By. AMY MCCURDY Sheet Title: COVER SHEET Williams Mechanical J Co o ti QCoto o to N r 5,ga H 0 o � F.: 0 N tC1 tt� N cn � UJ � d � H N M O IZ_ V_ ,sob Humber. 1005 Date: LARCH 02, 2016 Principal In Charge: VWAM RRIM Project Manager VMD KHASTDU Drawn By. AMY MCCURDY Sheet Title: COVER SHEET Williams Mechanical Co o ti QCoto o to N r 5,ga � 0 o � F.: 0 ,sob Humber. 1005 Date: LARCH 02, 2016 Principal In Charge: VWAM RRIM Project Manager VMD KHASTDU Drawn By. AMY MCCURDY Sheet Title: COVER SHEET Williams Mechanical 5,ga Y F.: ,sob Humber. 1005 Date: LARCH 02, 2016 Principal In Charge: VWAM RRIM Project Manager VMD KHASTDU Drawn By. AMY MCCURDY Sheet Title: COVER SHEET Williams Mechanical SITE PLAN (] ll /_ SIDEWALK 0o000o000000000000000o0 00 o 00000000 Oo 000000000 o c _ oo000000000000000000000 00 000 00 00000000000 00 000000000000000000000oo 0000000 o0ooa0000000oo00 CV 0000 00000E 00000000000 000 000000000000000000 PROVIDE TRUNCATED DOMES AT RAMP SETBACK TRUNCATED DOMES RAMP PER CHART ABOVE PER PLAN 6" TO 8" FROM CURB FACE �A D�A�C �UR�B /�R A�M�P �= �TY� P A i C 0 PLAN DETAIL C) T /____7r ELEVATION 1/4"=l 1 -0" TOP OF R; Vr R 25 , \ TRASH/RECYCLE\O ,p� oa ENCLOSURE \F�B9 DU'1�! S� /SFR, \ Wq TER Thi iki­Trn DOMES PER PLAN TOOLED JOINTS @ 3/4- )E BAND CURB & GUTTER CONDITION WHERE OCCURS TRANISITIONS FROM RAMP TO WALKS, GUTTERS, VECHICLAR WAYS SHALL BE FLUSH W/ NO ABRUPT CHANGES GREATER THAN 1/4" IN HEIGHT IF EITHER LANDING AREA IS LESS THAN 48" IN THE DIRECTION OF TRAVEL THE FLARED SIDE SLOPES SHALL BE REDUCED TO 1 TO 12 RISE TO RUN CURB RAMPS SHALL NOT BE POURED INTERGAL W/ SIDEWALKS AND SHALL BE ISOLATED BY 3/8" THICK EXPAN. JT. MATERIAL ON ALL SIDES ABUTTING THE SIDEWALK. 1/431=1 P-011 BACKGRO (2) COAT' 3" WIDE PAINTED STRIPES, PAINT (2) COATS WHITE BEADED REFLECTIVE PAINT INTERNATIONAL SYMBOL OF ACCESSIBILITY COMPLYING 0 ANSI A117.1-2003 SECTION A � A�C�C E�S �Sw '-0" CONC. SIDEWALK TRASH/RECYCLE CONCRETE CURB OR 4" WIDE STRIPING STRIPING AS OCCURS PER SITE PLAN OF STALL EQ 1'-6" L 1'-6" EQ NTS 0 i 'N WITH END OF ,31HLL STRIPING - J ", �ll lib T PARKING CALCULATIONS REQUIRED: ** R E C IW WAREHOUSE: 10 •1 �i RETAIL: 2,342 SF @ 2.5:1000 = 5.8 STALLS 58,737 SF 62.5 TOTAL PROVIDED: I 22 - LONG 10 x 30 011��� 0o000o000000000000000o0 00 o 00000000 Oo 000000000 o c _ oo000000000000000000000 00 000 00 00000000000 00 000000000000000000000oo 0000000 o0ooa0000000oo00 CV 0000 00000E 00000000000 000 000000000000000000 PROVIDE TRUNCATED DOMES AT RAMP SETBACK TRUNCATED DOMES RAMP PER CHART ABOVE PER PLAN 6" TO 8" FROM CURB FACE �A D�A�C �UR�B /�R A�M�P �= �TY� P A i C 0 PLAN DETAIL C) T /____7r ELEVATION 1/4"=l 1 -0" TOP OF R; Vr R 25 , \ TRASH/RECYCLE\O ,p� oa ENCLOSURE \F�B9 DU'1�! S� /SFR, \ Wq TER Thi iki­Trn DOMES PER PLAN TOOLED JOINTS @ 3/4- )E BAND CURB & GUTTER CONDITION WHERE OCCURS TRANISITIONS FROM RAMP TO WALKS, GUTTERS, VECHICLAR WAYS SHALL BE FLUSH W/ NO ABRUPT CHANGES GREATER THAN 1/4" IN HEIGHT IF EITHER LANDING AREA IS LESS THAN 48" IN THE DIRECTION OF TRAVEL THE FLARED SIDE SLOPES SHALL BE REDUCED TO 1 TO 12 RISE TO RUN CURB RAMPS SHALL NOT BE POURED INTERGAL W/ SIDEWALKS AND SHALL BE ISOLATED BY 3/8" THICK EXPAN. JT. MATERIAL ON ALL SIDES ABUTTING THE SIDEWALK. 1/431=1 P-011 BACKGRO (2) COAT' 3" WIDE PAINTED STRIPES, PAINT (2) COATS WHITE BEADED REFLECTIVE PAINT INTERNATIONAL SYMBOL OF ACCESSIBILITY COMPLYING 0 ANSI A117.1-2003 SECTION A � A�C�C E�S �Sw '-0" CONC. SIDEWALK TRASH/RECYCLE CONCRETE CURB OR 4" WIDE STRIPING STRIPING AS OCCURS PER SITE PLAN OF STALL EQ 1'-6" L 1'-6" EQ NTS 0 i 'N WITH END OF ,31HLL STRIPING - J ", �ll lib T PARKING CALCULATIONS REQUIRED: ** R E C IW WAREHOUSE: 56,990 SF @ 1:2000 = 28.5 STALLS OFFICE: 9,405 SF @ 3:1000 = 28.2 STALLS RETAIL: 2,342 SF @ 2.5:1000 = 5.8 STALLS 58,737 SF 62.5 TOTAL PROVIDED: I 22 - LONG 10 x 30 011��� 27 - STANDARD (9' X 19') i 4 - COMPACT STALLS (8' X 17' ANGLED) 5-0° MV 10 - COMPACT STALLS (8' X 16') c � 63 TOTAL INCL. 4 HC STALLS E_ !n1 i nAnn,in nnnvc, /nn' __ -l\ SITE AREA: 141,868 SF (3.3 ACRES) 1 PICNIC TABLE AREA TRUNCATED DOMES AT PED CROSSINGS - TYP. 100.7' PROPERTY LINE L 200' SETBACK w 65' BUS 6" 1 6" ACCESSIBLE PARKING SIGN "SAFE -HIT" FLEXIBLE POST W/ "SMT" TWIST LOCK BASE. BOLT TO CONCRETE WALKWAY OR ASPHALT SURFACE. LINE OF PAVING VAN ACCESSIBLE PARKING SIGN, SEE SITE PLAN FOR LOCATION(S) NOTES: 1. ACCESSIBLE PARKING SIGNS SHALL COMPLY WITH ICC/ANSI A117.1-2003. 2. BUILDING MOUNT (AS OCCURS): MOUNT SIGN ON WALL WITH (2) EXPANSION ANCHORS. `t,s�" �> R E C IW C4 CR 8 CITY OF U10PALA JUL 12 2016 C I PERPAIT CENTER I RESERVED PARKING 011��� i °°20 5-0° MV VAN - ACCESSIBLE `D VAN ACCESSIBLE PARKING SIGN, SEE SITE PLAN FOR LOCATION(S) NOTES: 1. ACCESSIBLE PARKING SIGNS SHALL COMPLY WITH ICC/ANSI A117.1-2003. 2. BUILDING MOUNT (AS OCCURS): MOUNT SIGN ON WALL WITH (2) EXPANSION ANCHORS. `t,s�" �> Job Numbs: 1005 Dots ARCH 02, 2016 Princlpd in Charge: 1MIM RATER Project Afanager: VARD KHASTDU Drawn 8y. AMY MOCURDY Sheet Me: SITE PLAN & SITE DETAILS S¢ N& J C4 CR 8 C I OD 011��� °°20 o i E4.2 c � u E_ N a 0 til v F Cn >lY W a Q rY F- r N i Q r o M LC3 Z r Job Numbs: 1005 Dots ARCH 02, 2016 Princlpd in Charge: 1MIM RATER Project Afanager: VARD KHASTDU Drawn 8y. AMY MOCURDY Sheet Me: SITE PLAN & SITE DETAILS S¢ N& C4 CR 8 C I OD 011��� °°20 o i E4.2 c � u N a 0 v Job Numbs: 1005 Dots ARCH 02, 2016 Princlpd in Charge: 1MIM RATER Project Afanager: VARD KHASTDU Drawn 8y. AMY MOCURDY Sheet Me: SITE PLAN & SITE DETAILS S¢ N& 011��� MIA r �s.,aurti Job Numbs: 1005 Dots ARCH 02, 2016 Princlpd in Charge: 1MIM RATER Project Afanager: VARD KHASTDU Drawn 8y. AMY MOCURDY Sheet Me: SITE PLAN & SITE DETAILS S¢ N& i J I, 1, ! ■ ■ ■VMM■CZM3 ■ EEM ■ a= ■ ■ IMEM ■ a= ■ 10011aman admimm ■ Emma■ comma ■ cisma ■ ■ a= ■ emma meams ■ ■ a= aimmin ■ Cimino ommais =ME ® Wma ■ C= ® MM acmami■ Emma messm amma ■ Mw ■ ■ ■am ■ a= ■ =m auman ■ ■ ■ ■ C=I Existing 21b Gas meter AL -425 MAOP 10 PSI ANSI class 400 Existing 75,000 gas unit heater Lndvalve LINE r o existing tap on a 21b - - - --I �- I j I 1 i I 1 I WAREHOUSE i 3,700 SF I � ; I W5 j I � � I' I RTU— with economizer 7'- 1 YORK ZXG08E4B1AA1B111A2 Total capacity 94.9 MBH Sensible capacity 67.4 MBH Refrigerant type R-41 OA _ Efficiency (at ARI) 11.00 EER Integrated eff. (at ARI) 11.50 IEER Ambient DB temp. 95.0 OF Entering DB temp. 80.0 OF Entering WB temp. 67.0 OF Leaving DB temp. 59.2 OF i Leaving WB temp. 57.0 OF ! Power Input (w/o blower) 6.63 kW Sound power 84 dB(A) Gas Heating Performance Entering DB temp. 60 OF Heating output capacity (Max) 144 MBH Supply air 3000 CFM Heating input capacity (Max) 180 MBH Leaving DB temp. 104.4 OF Air temp. rise 44.4 OF SSE 80.0 % Stages 2 Supply Air Blower Performance Supply air 3000 CFM Ext. static pressure 0.6 IWG Addl. Unit Losses (Options/Accessories) 0.17 IWG Blower speed 815 RPM Max BNP of Motor (including service factor) 2.90 HP Duct location Bottom Actual required BHP 1.56 HP Power input 1.44 kW Elevation 0 ft. Drive type BELT Electrical Data Power supply 460-3-60 Unit min circuit ampacity 19.7 Amps Unit min over -current protection 20 Amps Unit max over -current protection 25 Amps Dimensions & Weight Hgt 41 in. Len 87 in. Wth 62 in. Weight with factory installed options 903 lbs. Clearances Right 18 in. Front 48 in. Back 36 in. Top 72 in. Bottom 1 in. Left 12 in. 16'-4" ! I ! ' w3 is 103 3/4" drip, valve, union 101 STORAGE � 1 and regulator A2.4 I I (' 15'-8" RTU -1 On roof O W2 I I I W3 „ STORAG 60 RESTROOM SEE 2/A2'0 i i 105 I � ' 0 5'-4" ; 3'-4" ' O' C, I I,! co OPEN OFFICE #1 ADD INSULATION TO EXISITNG WALL 18'-5" W1 ! ! REVIEWED FOR J BODE COMPLIANCE APPROVED 4 !'' t !; JUL 2 6 2016 t�" j v i ! I 1 City of Tukwila BUILDING DIVISION i— ice—;U —_ {CITY OF TUKWILA ! t JUL 12 20e6 ! PERMIT CENTER I MECHANICAL SCHEDULE Gas sizing per International Fuel Code TAG MODE! CEM Gas input Economizer HP VOLTAGE AMPS Existing unit heater 75,000 BTU + RTU -1 180,000 BTU = 255,000 BTU Total RTU -1 York ZXG08E4B1AA1B111A2 3000 180.000 100% 2.9 460/3 20amp Existing 2 PSI meter EF -1+2 Nutone 80 115/1 1 " Line Capacity at 125ft table 1,530,000 BTU Capacity still available 1,175,000 BTU NOTE: American Meter regulator will be installed on roof reducing Gas — pressure to standard inches water column with vent to lbnoswde J O N � j t�" j v r CO F I� m J gr L I ai ; a g U2 v t/) H � cn Y W � a Q � IN cid r N w � QT co O z r O N � j t�" j v r CO I� m J gr L I ai ; a g U2 v .j iii c4 ff? 9 C4 i-7 co F1ch C8 C8 31 x15 supply up to R 1 TU -1 to and 16" supply down to lower level OPEN OFFICE 10'–C" A.F.F C8 A. C. T. C 8 [=C8 -- ----------- U el000� 7F14" 16" 47C8 C8 Ffl 46 fl �0" 375 10" 375 CFM T Typ of yp of 4 LETI— .j c4 ff? 9 C4 i-7 co F1ch 8 46 W LU < c. -I cf) 6-14TI I I I c4 ff? 9 C4 i-7 co F1ch 8 46 ,` .. T b i._ . NOTES ■ 1. POST BUILDING ADDRESS SIGN ON FRONT OF BUILDING AS REQUIRED BY BUILDING OFFICIAL. COORDINATE WITH ARCHITECT. 2. CONTRACTOR IS SOLELY AND COMPLETELY RESPONSIBLE FOR CONDITIONS OF THE JOB SITE, INCLUDING SAFETY, PROTECTION OF PROPERTY AND THE LIKE DURING THE PERFORMANCE OF THE WORK. 3. THE CONTRACTOR IS REQUIRED TO COMPLY WITH ALL APPLICABLE REGULATIONS AND CODES OF THE GOVERNING AUTHORITIES AND OWNERS. 4. PROVIDE METHODS, MEANS AND FACILITIES REQUIRED TO PREVENT CONTAMINATION OF SOIL, WATER OR ATMOSPHERE. 5. INSURE MINIMUM INTERFERENCE WITH EXISTING ROADS, STREETS, SIDEWALKS, PARKING FACILITIES AND ADJACENT FACILITIES. DO NOT CLOSE OR OBSTRUCT WITHOUT PRIOR APPROVAL. 6. ALL SALVAGE WILL BECOME THE PROPERTY OF THE CONTRACTOR, UNLESS NOTED OTHERWISE (UNO). PROMPTLY REMOVE FROM SITE AND LEGALLY DISPOSE OF ALL SAID MATERIAL AT CONTRACTOR'S EXPENSE. 7. DIMENSIONS ARE TO: - FACE OF MASONRY OR CONCRETE, CENTER LINE OF COLUMNS, FACE OF STUD, OR FACE OF MULLION UNLESS NOTED OTHERWISE. - DIMENSIONS INDICATED CLEAR (CLR) ARE TO FINISH FACE. - DIMENSIONS TO DOOR AND WINDOW OPENINGS ARE ROUGH MASONRY OPENINGS UNO. - ALL MASONRY DIMENSIONS ARE NOMINAL. 8. SCRIBE GYPSUM BOARD OF WALLS AND PARTITIONS TO IRREGULARITIES OF STRUCTURE OR DECK ABOVE AND SEAL TIGHTLY AROUND ALL PENETRATIONS. 9. IT IS THE RESPONSIBILITY OF THE CONTRACTOR TO COORDINATE WITH THE OWNER'S WORK AND/OR SUPPLIED ITEMS THAT ARE "FURNISHED BY THE OWNER AND INSTALLED BY THE CONTRACTOR" OR "NOT IN CONTRACT" (NIC), BUT ARE ATTACHED TO CONTRACTOR'S WORK. 10. ALL RAMPS TO HAVE MAXIMUM 1:12 SLOPE. RAMPS WITH SLOPE OF 1:20 OR GREATER TO HAVE HANDRAILS PER WASHINGTON STATE HANDICAP CODE. 11. ALL STAIRS TO HAVE MINIMUM 11" TREADS AND MAXIMUM 7" RISERS, UNO. 12. MINIMUM ROOF SLOPE SHALL BE 1/4"=1'-0". _ 13. CONTRACTOR IS RESPONSIBLE FOR REVIEWING THE DRAWINGS AND SPECIFICATIONS AND WITH THE NOTIFICATION OF THE ARCHITECT OF ANY DISCREPENCIES WITHIN THE DOCUMENTS AND THE SCOPE OF WORK. CONTRACTOR IS RESPONSIBLE TO COORDINATE ANY AND ALL REVISIONS TO THE DRAWINGS. 14. FIRE EXTINGUISHERS TO BE LOCATED PER FIRE MARSHALL'S DIRECTION. AS REQ'D. 15. ALL ROUGH -INS SHALL BE APPROVED PRIOR TO FRAMING INSPECTION. 16. PROVIDE ONE 2A-10BC FIRE EXTINGUISHER PER 3,000 SQ.FT. OR EACH 75' OF TRAVEL DISTANCE, AS REQUIRED BY FIRE MARSHALL. 17. EXIT LIGHTING SHALL BE PROVIDED WHEN TWO EXITS ARE REQUIRED. THE EMERGENCY SYSTEM SHALL BE SUPPLIED BY A SEPARATE SOURCE OF POWER AND HAVE AN EMERGENCY BACK UP SYSTEM. EXITS SHALL BE ILLUMINATED AT ANY TIME THE BUILDING IS OCCUPIED WITH EMERGENCY LIGHTING HAVING THE INTENSITY OF NOT LESS THAN 1 FOOT CANDLE AT FLOOR LEVEL. IBC SECTION 1006.3. 18. EXIT DOORS SHALL BE OPENABLE FROM THE INSIDE WITHOUT THE USE OF A KEY OR ANY SPECIAL KNOWLEDGE OR EFFORT. 19. EXCEPTION: KEY -LOCKING HARDWARE MAY BE USED ON THE MAIN EXIT WHEN THE MAIN EXIT CONSISTS OF A SINGLE DOOR OR PAIR OF DOORS IF THERE IS A READILY VISIBLE, DURABLE SIGN ON OR ADJACENT TO THE DOOR STATING "THIS DOOR TO REMAIN UNLOCKED DURING BUSINESS HOURS." THE SIGN SHALL BE IN LETTERS NO LESS THAN 1 INCH HIGH ON CONTRASTING BACKGROUND. WHEN LOCKED, THE SINGLE DOOR OR BOTH LEAVES OF A PAIR OF DOORS MUST BE FREE TO SWING WITHOUT OPERATION OF ANY LATCHING DEVICE. 20. TRASH DUMPSTERS AND COMPACTORS SHALL BE PROVIDED WITH RUBBER WHEELS N.I.C. 21. EXTERIOR JOINTS AROUND WINDOWS AND DOOR FRAMES, OPENINGS BETWEEN WALLS AND FOUNDATIONS, BETWEEN WALLS AND ROOF AND WALL PANELS; OPENINGS AT PENETRATIONS OF UTILITY SERVICES THROUGH WALLS, FLOORS AND ROOFS; AND ALL OTHER OPENINGS IN THE BUILDING ENVELOPE SHALL BE SEALED, CAULKED, GASKETED OR WEATHERSTRIPPED TO LIMIT AIR LEAKAGE. t-{�pir Y F� % 1 1 k C ""�a, 1, s L� 22. BUILDING INSULATION SHALL BE PROVIDED AS INDICATED IN DWGS. W/ R VALUES PER ENERGY CALCULATIONS. 23. EVERY HANDICAPPED PARKING SPACE SHALL BE IDENTIFIED BY A SIGN CENTERED ON THE STALL. THE BOTTOM OF THE SIGN NEEDS TO BE 60 INCHES ABOVE THE PARKING SURFACE, AT THE HEAD OF THE PARKING SPACE. THE SIGN SHALL INCLUDE THE INTERNATIONAL SYMBOL OF ACCESS AND THE PHRASE "STATE DISABLED PARKING PERMIT REQUIRED". PROVISION UNDER SITE DEVELOPMENT PERMIT. 24. THIS DRAWING IS AN INSTRUMENT OF SERVICE ONLY. THE COPYRIGHT TO THIS DRAWING BELONGS TO THE ARCHITECT. NO PERSON MAY USE THIS DRAWING FOR ANY PURPOSE OTHER THAN THE INTENDED ORIGINAL PURPOSE FOR THE ORIGINAL CLIENT. THIS DRAWING MAY NOT BE REPRODUCED IN WHOLE OR IN PART, IN ANY MANNER OR STORED IN ANY FORM FOR REPRODUCTION WITHOUT THE EXPRESS PERMISSION OF THE ARCHITECT. NO VALUE SHOULD BE SCALED AND ALL VALUES SHOULD BE CHECKED AGAINST FIELD VALUES AND/OR CHECKED WITH THE ARCHITECT. IF ANY VALUES IS FOUND TO BE INCORRECT OR INVALID, THEN IT IS THE RESPONSIBILITY OF THE USER TO INFORM THE ARCHITECT AND TO OBTAIN THE CORRECT VALUE FROM THE ARCHITECT PRIOR TO ACTING. 25. PER W.S.E.C. SECTION 1416.3.2 ACCEPTANCE: FINAL CERTIFICATE OF OCCUPANCY SHALL NOT BE ISSUED UNTIL THE BUILDING OFFICIAL DETERMINES THAT THE PRELIMINARY COMMISSIONING REPORT REQUIRED BY SECTION 1416.2.6.2 HAS BEEN COMPLETED. IF THIS DRAWING WAS CREATED AND/OR TRANSFERRED ON ELECTRONIC MEDIA TO ANY OTHER PERSON OR BODY, THEN THE USER SHOULD BE AWARE THAT THE DRAWING MAY HAVE BEEN ALTERED AFTER ISSUE BY THE ARCHITECT. THE ONLY ORIGINAL OF THIS DRAWING RESIDES IN THE FILES OF THE ARCHITECT, AND SHALL TAKE PRECEDENT OVER ALL COPIES, PAPER OR ELECTRONIC. THIS DRAWING MAY CONTAIN MATERIAL WHICH WAS PROVIDED FOR INFORMATION ONLY TO THE ARCHITECT BY THE CLIENT OR CLIENTS CONSULTANTS. THE ARCHITECT ACCEPTS NO RESPONSIBILITY FOR THE ACCURACY OR THE COMPLETENESS OF THIS MATERIAL. IF VALUES IN THE DRAWING ARE FOUND TO BE CRITICAL TO THE SCOPE OF WORK, THEN THE USER IS ADVISED TO REFER BACK TO THE ORIGINAL MATERIALS IN THE HANDS OF THE CLIENT. FIRE CODE FIRE ADDRESS: APPROVED ADDRESS SHALL BE PROVIDED FOR ALL BUILDINGS IN SUCH A POSITION AS TO BE PLAINLY VISIBLE AND LEGIBLE FROM THE STREET OR ROAD FRONTING THE PROPERTY. FIRE ADDRESS/TEMPORARY: TEMPORARY ADDRESSING IS REQUIRED DURING CONSTRUCTION SHALL BE VISIBLE FROM THE STREET. FIRE KNOX BOX: IF THE BUILDING OR SUITE HAS A FIRE PROTECTION SYSTEM, A KNOX BOX SHALL BE INSTALLED IN AN APPROVED LOCATION AND ALL REQUIRED KEYS SHALL BE ON SITE FOR LOCK UP PRIOR TO BUILDING FIRE FINAL. FIRE OCCUPANT LOAD: OCCUPANT LOAD SHALL BE POSTED IN A CONSPICUOUS LOCATION AT OR AROUND THE MAIN EXIT. PORTABLE FIRE EXTINGUISHER: PORTABLE FIRE EXTINGUISHER WILL BE REQUIRED DURING CONSTRUCTION AND INSTALLED FOR FINAL INSPECTION. CLASS 2A 106C TYPE IS/ARE REQUIRED. PLEASE MOUNT THE EXTINGUISHER(S) IN A CONSPICUOUS LOCATION APPROVED BY THE FIRE DEPARTMENT AND LOCATE THE EXTINGUISHER(S) SO THAT THE TRAVEL DISTANCE FROM ANY POINT IN SPACE DOES NOT EXCEED 75 FEET TO AN EXTINGUISHER. (THE DISTANCE BETWEEN EXTINGUISHERS CAN BE 150 FEET), FIRE SPRINKLER SYSTEM: STRUCTURE SHALL HAVE A FIRE SPRINKLER INSTALLED PER NFPA AND EASTSIDE FIRE & RESCUE REQUIREMENTS. SUBMIT FOR A FIRE PERMIT. AC ACCOUSTIC FIXT FIXTURE OD OUTSIDE DIAMETER EXISTING BUILDING- NO CHANGES TO BUILDING ENVELOPE. ADD ADDENDUM FL FLASHING OFS OVERFLOW Type VB SPPINKLERED ADD'N ADDITION FLR FLOOR Wind Exposure / Seismic Zone SCUPPER Proposed Building Uses/Exits Required ABC AGGREGATE BASE F.D. FLOOR DRAIN OFD OVERFLOW DRAIN COURSE FLUOR FLUORESCENT AGG AGGREGATE FTG FOOTING PARA PARAPET A/C AIR CONDITIONING FND FOUNDATION PTD PAINTED AL ALUMINIUM FR FRAME PG PAGE ALT ALTERNATE FHC FIRE HOSE CABINET PR PAIR AB ANCHOR BOLT FV FIELD VERIFY PNL PANEL ABV ABOVE PTN PARTITION & AND GA GAUGE d PENNY ARCH ARCHITECT GI GALVANIZED IRON PL PLATE ASP ASPHALT GL GLASS PLBG PLUMBING GD GRADE PLYWD PLYWOOD BSMT BASEMENT GYP GYPSUM PT POINT BM BEAM GWB GYPSUM WALL PSI POUNDS PER BEL BELOW BOARD SQUARE INCH B.M. BENCHMARK GRND GROUND PSF POUNDS PER BLKG BLOCKING SQUARE FOOT BD BOARD HR HANDRAIL PC PRECAST BO BOTTOM OF HDN HARDENER PL PROPERTY LINE BLDG BUILDING HDW HARDWARE HDWD HARDWOOD R RADIUS CABT CABINET HTR HEATER REG REGISTER C.I.P. CAST IN PLACE HT HEIGHT REQ'D REQUIRED C.B. CATCH BASIN HP HIGH POINT REV REVISION CLG CEILING H.M. HOLLOW METAL RD ROOF DRAIN CEM CEMENT HORIZ HORIZONTAL RFG ROOFING CG CENTIGRAM HB HOSE BIB RM ROOM CL CENTER LINE HW HOT WATER RGH ROUGH CER CERAMIC RD ROUND C.T. CERAMIC TILE IN INCH CHAN. CHANNEL ID INSIDE DIAMETER SCR SCREW CLR CLEAR INSUL INSULATION SECT SECTION C.O. CLEAN OUT INT INTERIOR SEL SELECT CLOS CLOSET INV INVERT SHT SHEET COL COLUMN SDG SIDING CONIC CONCRETE JAN JANITOR Sim SIMILAR CONN CONNECTION JT JOINT SLDG SLIDING SYMB"OLS CONST CONSTRUCTION JST JOIST SM SMOOTH CJ. CONTROL JOINT SPEC SPECIFICATION _ CONSTRUCTION JOINT KP KICK PLATE SPL SPLASH CONT CONTINUOUS SQ SQUARE GRID LINE X - CONTR CONTRACTOR LAM LAMINATED STD STANDARD COR'G CORRUGATED LDG LANDING SS STAINLESS STEEL CTR COUNTER LAV LAVATORY STRUC STRUCTURE now CTSK COUNTERSINK LG LENGTH SUSP SUSPENDED NAML CMU CONCRETE LOC LOCATION SWBD SWITCHBOARD DRAWING TITLE MASONRY UNIT LT LIGHT SCALE CMS CORRUGATED LWC LIGHT WEIGHT TC TOP OF CURB METAL SIDING CONCRETE TG TEMPERED GLASS LVR LOUVER T.O. TOP OFX SHEET # D. A. DAMP PROOFING LOC LOCATION T.S. TUBE STEEL DIAG DIAGONAL TSD TOP OF STEEL EXTERIOR X INTERIOR X X. X DIAM DIAMETER MO MASONRY OPENING DECK ELEVATION KEY A4.X ELEVATION KEY X DIM DIMENSION MATL MATERIAL TYP TYPICAL DISP DISPENSER MFR MANUFACTURER DWL DOWEL MAX MAXIMUM U.N.O. UNLESS NOTEDX DN DOWN MCJ MAS CNTRL JNT OTHERWISE DETAIL X ENLARGED AX.X D. S. DOWNSPOUT MECH MECHANICAL U.N.P. UNDER SEPARATE REFERENCE AX.X PLAN DWG DRAWING MET METAL PERMIT MTL METAL X EA EACH ML METAL LATH V VENT EL ELECTRIC MID MIDWAY / MIDDLE VERT VERTICAL AX.X EDF ELECTRIC DRINKING MIN MINIMUM VEST VESTIBULE FOUNTAIN MLDG MOULDING VCT VINYL COMPOSITION c ELEV ELEVATION MULL MULLION TILE EQ EQUAL NG NATURAL GRADE WWM WELDED WIRE MESH WALL SECTION X BUILDING X X EQUIP EQUIPMENT A5.X SECTION A4.0 A4.0 EXH EXHAUST NOM NOMINAL WC WATER CLOSET EXP EXPANSION N.I.C. NOT IN CONTRACT WH WATER HEATER EJ EXPANSION JOINT 0/ OVER WF WIDE FLANGE Z EXIST EXISTING OBS OBSERVE W/ WITH DOOR NUMBER(WINDOW TYPE 101 OH OC ON CENTER W/0 WITHOUT FT FEET OPG OPENING FIN FINISH OA OVERALL WALL TYPE �--- FINISH TAG X -X L I I N.T.S. Building Identifier: C Applicable Code: IBC 2012 Edition Site Area: 3.3 ACRES Zoning: C/LI Occupancy Groups: B Mixed Use Class Non Separated Uses Construction: Type VB SPPINKLERED Height 32 ft+/- (highest point) Number of Stories Two Wind Exposure / Seismic Zone NIA, Existing Structure Proposed Building Uses/Exits Required HVAC NOTES Scope of work is for HVAC mechanical only including one package unit RTU -1. Other information on these plans is for reference only. All duct fabrication and insulations per SMACNNA and WSEC standards. System will be commissioned per 2012 WSEC C408. See sheet M-3 for RTU -1 specifications. A receptacle outlet will be provided near by per N"IFPA 70 Gas piping and low voltage will be submitted with other permit ap601 plications. RLECopy permflt No. _M,1 62,_- 0-1.) -7- F:� T "V18�id FtPpr©v8I 1s st1*ct to errors and omi3Sio fs. Appi ov I Of 00nsiP' iaiiondocuments does not author;=8 t10 visa!;; !ik--�,0 of any adopted codo or ordinance. Reipi of app; oiled ieid Cc py and conditions is acknowledged: 1311 Y: --, Date: City Of Tula BUILDING DIVISIOI Ui TE PEP -MIT ED Pi 7 F019: DMechanical M'66'1111Cat [j Aumbing ►s Piping Lite Of Tukwila ''e' �`"'"� DIVI.S►nni r� t1 ^ s� } -all b3mldo 11ENIISIONS }/1 h eop of w,07% 11, prior approval of Building DhAsion. r,gL-ire a ne%v plan submittal and may in ,,Llde adv;tional plan review fees. REVIEWl ED FOR CODE COMPLIANCE APPROVED JUL 2 G 2016 Ct I? Of TU11 IIa BU1L0IN1Q (0tq _ RECIADV=D CI TURWiLA OF JUL 12 2016 PERMIT CENTER Area Occ. Load Factor Occ. Load Warehouse 3,70C 500 7 Office 1,01E 100 10 Total 1st floor 4,71E 27 18 HVAC NOTES Scope of work is for HVAC mechanical only including one package unit RTU -1. Other information on these plans is for reference only. All duct fabrication and insulations per SMACNNA and WSEC standards. System will be commissioned per 2012 WSEC C408. See sheet M-3 for RTU -1 specifications. A receptacle outlet will be provided near by per N"IFPA 70 Gas piping and low voltage will be submitted with other permit ap601 plications. RLECopy permflt No. _M,1 62,_- 0-1.) -7- F:� T "V18�id FtPpr©v8I 1s st1*ct to errors and omi3Sio fs. Appi ov I Of 00nsiP' iaiiondocuments does not author;=8 t10 visa!;; !ik--�,0 of any adopted codo or ordinance. Reipi of app; oiled ieid Cc py and conditions is acknowledged: 1311 Y: --, Date: City Of Tula BUILDING DIVISIOI Ui TE PEP -MIT ED Pi 7 F019: DMechanical M'66'1111Cat [j Aumbing ►s Piping Lite Of Tukwila ''e' �`"'"� DIVI.S►nni r� t1 ^ s� } -all b3mldo 11ENIISIONS }/1 h eop of w,07% 11, prior approval of Building DhAsion. r,gL-ire a ne%v plan submittal and may in ,,Llde adv;tional plan review fees. REVIEWl ED FOR CODE COMPLIANCE APPROVED JUL 2 G 2016 Ct I? Of TU11 IIa BU1L0IN1Q (0tq _ RECIADV=D CI TURWiLA OF JUL 12 2016 PERMIT CENTER J Co Office 864 100 9 Warehouse Storage 146 300 1 Total Mezzanine 1,01C 10 TOTAL 5.726 27 HVAC NOTES Scope of work is for HVAC mechanical only including one package unit RTU -1. Other information on these plans is for reference only. All duct fabrication and insulations per SMACNNA and WSEC standards. System will be commissioned per 2012 WSEC C408. See sheet M-3 for RTU -1 specifications. A receptacle outlet will be provided near by per N"IFPA 70 Gas piping and low voltage will be submitted with other permit ap601 plications. RLECopy permflt No. _M,1 62,_- 0-1.) -7- F:� T "V18�id FtPpr©v8I 1s st1*ct to errors and omi3Sio fs. Appi ov I Of 00nsiP' iaiiondocuments does not author;=8 t10 visa!;; !ik--�,0 of any adopted codo or ordinance. Reipi of app; oiled ieid Cc py and conditions is acknowledged: 1311 Y: --, Date: City Of Tula BUILDING DIVISIOI Ui TE PEP -MIT ED Pi 7 F019: DMechanical M'66'1111Cat [j Aumbing ►s Piping Lite Of Tukwila ''e' �`"'"� DIVI.S►nni r� t1 ^ s� } -all b3mldo 11ENIISIONS }/1 h eop of w,07% 11, prior approval of Building DhAsion. r,gL-ire a ne%v plan submittal and may in ,,Llde adv;tional plan review fees. REVIEWl ED FOR CODE COMPLIANCE APPROVED JUL 2 G 2016 Ct I? Of TU11 IIa BU1L0IN1Q (0tq _ RECIADV=D CI TURWiLA OF JUL 12 2016 PERMIT CENTER ,sob Humber. 1005 Date: LARCH 02, 2016 Principal In Charge: VWAM RRIM Project Manager VMD KHASTDU Drawn By. AMY MCCURDY Sheet Title: COVER SHEET Williams Mechanical J Co o ti QCoto o to N r 5,ga H 0 o � F.: 0 N tC1 tt� N cn � UJ � d � H N M O IZ_ V_ ,sob Humber. 1005 Date: LARCH 02, 2016 Principal In Charge: VWAM RRIM Project Manager VMD KHASTDU Drawn By. AMY MCCURDY Sheet Title: COVER SHEET Williams Mechanical Co o ti QCoto o to N r 5,ga � 0 o � F.: 0 ,sob Humber. 1005 Date: LARCH 02, 2016 Principal In Charge: VWAM RRIM Project Manager VMD KHASTDU Drawn By. AMY MCCURDY Sheet Title: COVER SHEET Williams Mechanical 5,ga Y F.: ,sob Humber. 1005 Date: LARCH 02, 2016 Principal In Charge: VWAM RRIM Project Manager VMD KHASTDU Drawn By. AMY MCCURDY Sheet Title: COVER SHEET Williams Mechanical SITE PLAN (] ll /_ SIDEWALK 0o000o000000000000000o0 00 o 00000000 Oo 000000000 o c _ oo000000000000000000000 00 000 00 00000000000 00 000000000000000000000oo 0000000 o0ooa0000000oo00 CV 0000 00000E 00000000000 000 000000000000000000 PROVIDE TRUNCATED DOMES AT RAMP SETBACK TRUNCATED DOMES RAMP PER CHART ABOVE PER PLAN 6" TO 8" FROM CURB FACE �A D�A�C �UR�B /�R A�M�P �= �TY� P A i C 0 PLAN DETAIL C) T /____7r ELEVATION 1/4"=l 1 -0" TOP OF R; Vr R 25 , \ TRASH/RECYCLE\O ,p� oa ENCLOSURE \F�B9 DU'1�! S� /SFR, \ Wq TER Thi iki­Trn DOMES PER PLAN TOOLED JOINTS @ 3/4- )E BAND CURB & GUTTER CONDITION WHERE OCCURS TRANISITIONS FROM RAMP TO WALKS, GUTTERS, VECHICLAR WAYS SHALL BE FLUSH W/ NO ABRUPT CHANGES GREATER THAN 1/4" IN HEIGHT IF EITHER LANDING AREA IS LESS THAN 48" IN THE DIRECTION OF TRAVEL THE FLARED SIDE SLOPES SHALL BE REDUCED TO 1 TO 12 RISE TO RUN CURB RAMPS SHALL NOT BE POURED INTERGAL W/ SIDEWALKS AND SHALL BE ISOLATED BY 3/8" THICK EXPAN. JT. MATERIAL ON ALL SIDES ABUTTING THE SIDEWALK. 1/431=1 P-011 BACKGRO (2) COAT' 3" WIDE PAINTED STRIPES, PAINT (2) COATS WHITE BEADED REFLECTIVE PAINT INTERNATIONAL SYMBOL OF ACCESSIBILITY COMPLYING 0 ANSI A117.1-2003 SECTION A � A�C�C E�S �Sw '-0" CONC. SIDEWALK TRASH/RECYCLE CONCRETE CURB OR 4" WIDE STRIPING STRIPING AS OCCURS PER SITE PLAN OF STALL EQ 1'-6" L 1'-6" EQ NTS 0 i 'N WITH END OF ,31HLL STRIPING - J ", �ll lib T PARKING CALCULATIONS REQUIRED: ** R E C IW WAREHOUSE: 10 •1 �i RETAIL: 2,342 SF @ 2.5:1000 = 5.8 STALLS 58,737 SF 62.5 TOTAL PROVIDED: I 22 - LONG 10 x 30 011��� 0o000o000000000000000o0 00 o 00000000 Oo 000000000 o c _ oo000000000000000000000 00 000 00 00000000000 00 000000000000000000000oo 0000000 o0ooa0000000oo00 CV 0000 00000E 00000000000 000 000000000000000000 PROVIDE TRUNCATED DOMES AT RAMP SETBACK TRUNCATED DOMES RAMP PER CHART ABOVE PER PLAN 6" TO 8" FROM CURB FACE �A D�A�C �UR�B /�R A�M�P �= �TY� P A i C 0 PLAN DETAIL C) T /____7r ELEVATION 1/4"=l 1 -0" TOP OF R; Vr R 25 , \ TRASH/RECYCLE\O ,p� oa ENCLOSURE \F�B9 DU'1�! S� /SFR, \ Wq TER Thi iki­Trn DOMES PER PLAN TOOLED JOINTS @ 3/4- )E BAND CURB & GUTTER CONDITION WHERE OCCURS TRANISITIONS FROM RAMP TO WALKS, GUTTERS, VECHICLAR WAYS SHALL BE FLUSH W/ NO ABRUPT CHANGES GREATER THAN 1/4" IN HEIGHT IF EITHER LANDING AREA IS LESS THAN 48" IN THE DIRECTION OF TRAVEL THE FLARED SIDE SLOPES SHALL BE REDUCED TO 1 TO 12 RISE TO RUN CURB RAMPS SHALL NOT BE POURED INTERGAL W/ SIDEWALKS AND SHALL BE ISOLATED BY 3/8" THICK EXPAN. JT. MATERIAL ON ALL SIDES ABUTTING THE SIDEWALK. 1/431=1 P-011 BACKGRO (2) COAT' 3" WIDE PAINTED STRIPES, PAINT (2) COATS WHITE BEADED REFLECTIVE PAINT INTERNATIONAL SYMBOL OF ACCESSIBILITY COMPLYING 0 ANSI A117.1-2003 SECTION A � A�C�C E�S �Sw '-0" CONC. SIDEWALK TRASH/RECYCLE CONCRETE CURB OR 4" WIDE STRIPING STRIPING AS OCCURS PER SITE PLAN OF STALL EQ 1'-6" L 1'-6" EQ NTS 0 i 'N WITH END OF ,31HLL STRIPING - J ", �ll lib T PARKING CALCULATIONS REQUIRED: ** R E C IW WAREHOUSE: 56,990 SF @ 1:2000 = 28.5 STALLS OFFICE: 9,405 SF @ 3:1000 = 28.2 STALLS RETAIL: 2,342 SF @ 2.5:1000 = 5.8 STALLS 58,737 SF 62.5 TOTAL PROVIDED: I 22 - LONG 10 x 30 011��� 27 - STANDARD (9' X 19') i 4 - COMPACT STALLS (8' X 17' ANGLED) 5-0° MV 10 - COMPACT STALLS (8' X 16') c � 63 TOTAL INCL. 4 HC STALLS E_ !n1 i nAnn,in nnnvc, /nn' __ -l\ SITE AREA: 141,868 SF (3.3 ACRES) 1 PICNIC TABLE AREA TRUNCATED DOMES AT PED CROSSINGS - TYP. 100.7' PROPERTY LINE L 200' SETBACK w 65' BUS 6" 1 6" ACCESSIBLE PARKING SIGN "SAFE -HIT" FLEXIBLE POST W/ "SMT" TWIST LOCK BASE. BOLT TO CONCRETE WALKWAY OR ASPHALT SURFACE. LINE OF PAVING VAN ACCESSIBLE PARKING SIGN, SEE SITE PLAN FOR LOCATION(S) NOTES: 1. ACCESSIBLE PARKING SIGNS SHALL COMPLY WITH ICC/ANSI A117.1-2003. 2. BUILDING MOUNT (AS OCCURS): MOUNT SIGN ON WALL WITH (2) EXPANSION ANCHORS. `t,s�" �> R E C IW C4 CR 8 CITY OF U10PALA JUL 12 2016 C I PERPAIT CENTER I RESERVED PARKING 011��� i °°20 5-0° MV VAN - ACCESSIBLE `D VAN ACCESSIBLE PARKING SIGN, SEE SITE PLAN FOR LOCATION(S) NOTES: 1. ACCESSIBLE PARKING SIGNS SHALL COMPLY WITH ICC/ANSI A117.1-2003. 2. BUILDING MOUNT (AS OCCURS): MOUNT SIGN ON WALL WITH (2) EXPANSION ANCHORS. `t,s�" �> Job Numbs: 1005 Dots ARCH 02, 2016 Princlpd in Charge: 1MIM RATER Project Afanager: VARD KHASTDU Drawn 8y. AMY MOCURDY Sheet Me: SITE PLAN & SITE DETAILS S¢ N& J C4 CR 8 C I OD 011��� °°20 o i E4.2 c � u E_ N a 0 til v F Cn >lY W a Q rY F- r N i Q r o M LC3 Z r Job Numbs: 1005 Dots ARCH 02, 2016 Princlpd in Charge: 1MIM RATER Project Afanager: VARD KHASTDU Drawn 8y. AMY MOCURDY Sheet Me: SITE PLAN & SITE DETAILS S¢ N& C4 CR 8 C I OD 011��� °°20 o i E4.2 c � u N a 0 v Job Numbs: 1005 Dots ARCH 02, 2016 Princlpd in Charge: 1MIM RATER Project Afanager: VARD KHASTDU Drawn 8y. AMY MOCURDY Sheet Me: SITE PLAN & SITE DETAILS S¢ N& 011��� MIA r �s.,aurti Job Numbs: 1005 Dots ARCH 02, 2016 Princlpd in Charge: 1MIM RATER Project Afanager: VARD KHASTDU Drawn 8y. AMY MOCURDY Sheet Me: SITE PLAN & SITE DETAILS S¢ N& i J I, 1, ! ■ ■ ■VMM■CZM3 ■ EEM ■ a= ■ ■ IMEM ■ a= ■ 10011aman admimm ■ Emma■ comma ■ cisma ■ ■ a= ■ emma meams ■ ■ a= aimmin ■ Cimino ommais =ME ® Wma ■ C= ® MM acmami■ Emma messm amma ■ Mw ■ ■ ■am ■ a= ■ =m auman ■ ■ ■ ■ C=I Existing 21b Gas meter AL -425 MAOP 10 PSI ANSI class 400 Existing 75,000 gas unit heater Lndvalve LINE r o existing tap on a 21b - - - --I �- I j I 1 i I 1 I WAREHOUSE i 3,700 SF I � ; I W5 j I � � I' I RTU— with economizer 7'- 1 YORK ZXG08E4B1AA1B111A2 Total capacity 94.9 MBH Sensible capacity 67.4 MBH Refrigerant type R-41 OA _ Efficiency (at ARI) 11.00 EER Integrated eff. (at ARI) 11.50 IEER Ambient DB temp. 95.0 OF Entering DB temp. 80.0 OF Entering WB temp. 67.0 OF Leaving DB temp. 59.2 OF i Leaving WB temp. 57.0 OF ! Power Input (w/o blower) 6.63 kW Sound power 84 dB(A) Gas Heating Performance Entering DB temp. 60 OF Heating output capacity (Max) 144 MBH Supply air 3000 CFM Heating input capacity (Max) 180 MBH Leaving DB temp. 104.4 OF Air temp. rise 44.4 OF SSE 80.0 % Stages 2 Supply Air Blower Performance Supply air 3000 CFM Ext. static pressure 0.6 IWG Addl. Unit Losses (Options/Accessories) 0.17 IWG Blower speed 815 RPM Max BNP of Motor (including service factor) 2.90 HP Duct location Bottom Actual required BHP 1.56 HP Power input 1.44 kW Elevation 0 ft. Drive type BELT Electrical Data Power supply 460-3-60 Unit min circuit ampacity 19.7 Amps Unit min over -current protection 20 Amps Unit max over -current protection 25 Amps Dimensions & Weight Hgt 41 in. Len 87 in. Wth 62 in. Weight with factory installed options 903 lbs. Clearances Right 18 in. Front 48 in. Back 36 in. Top 72 in. Bottom 1 in. Left 12 in. 16'-4" ! I ! ' w3 is 103 3/4" drip, valve, union 101 STORAGE � 1 and regulator A2.4 I I (' 15'-8" RTU -1 On roof O W2 I I I W3 „ STORAG 60 RESTROOM SEE 2/A2'0 i i 105 I � ' 0 5'-4" ; 3'-4" ' O' C, I I,! co OPEN OFFICE #1 ADD INSULATION TO EXISITNG WALL 18'-5" W1 ! ! REVIEWED FOR J BODE COMPLIANCE APPROVED 4 !'' t !; JUL 2 6 2016 t�" j v i ! I 1 City of Tukwila BUILDING DIVISION i— ice—;U —_ {CITY OF TUKWILA ! t JUL 12 20e6 ! PERMIT CENTER I MECHANICAL SCHEDULE Gas sizing per International Fuel Code TAG MODE! CEM Gas input Economizer HP VOLTAGE AMPS Existing unit heater 75,000 BTU + RTU -1 180,000 BTU = 255,000 BTU Total RTU -1 York ZXG08E4B1AA1B111A2 3000 180.000 100% 2.9 460/3 20amp Existing 2 PSI meter EF -1+2 Nutone 80 115/1 1 " Line Capacity at 125ft table 1,530,000 BTU Capacity still available 1,175,000 BTU NOTE: American Meter regulator will be installed on roof reducing Gas — pressure to standard inches water column with vent to lbnoswde J O N � j t�" j v r CO F I� m J gr L I ai ; a g U2 v t/) H � cn Y W � a Q � IN cid r N w � QT co O z r O N � j t�" j v r CO I� m J gr L I ai ; a g U2 v .j iii c4 ff? 9 C4 i-7 co F1ch C8 C8 31 x15 supply up to R 1 TU -1 to and 16" supply down to lower level OPEN OFFICE 10'–C" A.F.F C8 A. C. T. C 8 [=C8 -- ----------- U el000� 7F14" 16" 47C8 C8 Ffl 46 fl �0" 375 10" 375 CFM T Typ of yp of 4 LETI— .j c4 ff? 9 C4 i-7 co F1ch 8 46 W LU < c. -I cf) 6-14TI I I I c4 ff? 9 C4 i-7 co F1ch 8 46