Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Permit M16-0126 - KEYENCE - AIR DIFFUSERS AND GRILLES
KEYENCE 16040 CHRISTENSEN RD 205 M16-0126 City of Tukwila • Department of Community Development + 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Inspection Request Line: 206-438-9350 Web site: http://www.TukwilaWA.Rov MECHANICAL PERMIT Parcel No: 2523049039 Permit Number: M16-0126 Address: 16040 CHRISTENSEN RD 205 Issue Date: 9/6/2016 Permit Expires On: 3/5/2017 Project Name: KEYENCE Owner: Name: BRCP RIVERVIEW PLAZA LLC Address: 248 HOMER AVE, PALO ALTO, WA, 94301 Contact Person: Name: TOM REDDY Phone: (206) 933-6036 Address: 1400 AIRPORT WAY S SUITE 202, SEATTLE, WA, 98134 Contractor: Name: UNITED SYSTEMS MECHANICAL LLC Phone: (206) 933-6036 Address: 1400 AIRPORT WAY S #202, SEATTLE, WA, 98134 License No: UNITESM962QA Expiration Date: 11/1/2016 Lender: Name: Address: DESCRIPTION OF WORK: RELOCATE (13) SUPPLY AIR DIFFUSERS AND (4) RETURN AIR GRILLES. FURNISH AND INSTALL (1) NEW SUPPLY AIR GRILLE AND (4) NEW RETURN AIR GRILLES. Valuation of Work: $4,995.00 Fees Collected: $258.96 Type of Work: REPLACEMENT Fuel type: ELECT Electrical Service Provided by: PUGEST SOUND ENERGY Water District: TUKWILA Sewer District: TUKWILA Current Codes adopted by the City of Tukwila: International Building Code Edition: 2015 National Electrical Code: 2014 international Residential Code Edition: 2015 WA Cities Electrical Code: 2014 International Mechanical Code Edition: 2015 WAC 296-4613: 2014 Uniform Plumbing Code Edition: 2015 WA State Energy Code: 2015 International Fuel Gas Code: 2015 Permit Center Authorized Signature: I hearby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this development permit and agree totheconditions attached to this permit. Signature: Date: 4-1 r K� Print Name: This permit shall become null and void if the work is not commenced within 180 days for the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. PERMIT CONDITIONS: 1: Work shall be installed in accordance with the approved construction documents, and any changes made during construction that are not in accordance with the approved construction documents shall be resubmitted for approval. 2: All permits, inspection record card and approved construction documents shall be kept at the site of work and shall be open to inspection by the Building Inspector until final inspection approval is granted. 3: All construction shall be done in conformance with the Washington State Building Code and the Washington State Energy Code. 4: Remove all demolition rubble and loose miscellaneous material from lot or parcel of ground, properly cap the sanitary sewer connections, and properly fill or otherwise protect all basements, cellars, septic tanks, wells, and other excavations. Final inspection approval will be determined by the building inspector based on satisfactory completion of this requirement. 5: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206-431-3670). 6: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center. 7: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. 8: ***MECHANICAL PERMIT CONDITIONS*** 9: All mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center (206/431-3670). 10: Manufacturers installation instructions shall be available on the job site at the time of inspection. PERMIT INSPECTIONS REQUIRED Permit Inspection Line: (206) 438-9350 1800 MECHANICAL FINAL 0701 ROUGH -IN MECHANICAL CITY OF TUKWIL Community Development Department Permit Center • 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://www.TukwilaWA.gov Mechanical Permit No. I Q Project No. Date Application Accepted: Date Application Expires: 77 For office use only MECHANICAL PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. **please print** SITE LOCATION King Co Assessor's Tax No.: 252304-9039 Site Address: 16040 Christensen Road - Bldg 1 Suite Number: 202,205 Floor: 2 Tenant Name: Keyence New Tenant: © .....Yes ❑..No PROPERTY OWNER Name: ERCP Riverview Plaza, LLC Address: 248 Homer Avenue City: Palo Alto State: CA zip: 94301 CONTACT PERSON — person receiving all project communication Name: Tom Reddy Address: 1400 Airport Way South, Ste 202 City: Seattle State: WA Zip: 98134 Phone: (206) 933-6036 Fax: (206) 937-3084 Email: tom@us-mechanical.com Valuation of project (contractor's bid price): $ 4,995 Describe the scope of work in detail: MECHANICAL CONTRACTOR INFORMATION Company Name: United Systems Mechanical, LLC Address: 1400 Airport Way South, Ste 202 City: Seattle State: WA zip: 98134 Phone: (206) 933-6036 Fax: (206) 937-3084 Contr Reg No.: UNITESM962QA Exp Date: 11/01/2016 [Tukwila Business License No.: BUS -0993950 Relocate 13 supply air diffusers and 4 return air grilles. Furnish and install 1 new supply air grille and 4 new return air grilles. Use: Residential: New .......... ❑ Replacement ........ ❑ Commercial: New .......... ❑ Replacement ........ ❑ Fuel Type: Electric..... ❑ Gas ....... ❑ Other:_ li:\Applications\Forms-Applications On Line12016 ApplicationsWechanical Permit Application Revised 1-4-16.docx Revised: January 2016 Page 1 of 2 bh Indicate type of mechanical work being installed and the quantity below: Unit Type Qty Furnace <100k btu Residential, Nighttime Furnace > 100k btu ?" Floor furnace 55 dB(A) Suspended/wall/floor mounted heater 57 dB(A) Appliance vent Commercial Repair or addition to heat/refrig/cooling system 47 dB(A) Air handling unit <10,000 cfin 65 dB(A) Unit Type Qty Air handling unit >I 0,000 cfin Residential, Nighttime Evaporator cooler ?" Ventilation fan connected to single duct 55 dB(A) Ventilation system 57 dB(A) Hood and duct Commercial incinerator — domestic 47 dB(A) Incinerator — comm/industrial 65 dB(A) Unit Type Qty Fire damper Residential, Nighttime Diffuser ?" Thennostat 55 dB(A) Wood/gas stove 57 dB(A) Emergency enerator Commercial Other mechanical equipment 47 dB(A) 60 d13(A) 65 dB(A) Boiler/Compressor Qty 0-3 hp/100,000 btu 3-15 h /500,000 btu 15-30 hp/1,000,000 btu 30-50 hp/1,750,000 btu 50+ h /1,750,000 btu Noise: Mechanical units need to be in compliance with the Tukwila Noise Code. Maximum permissible sound levels are based on from where the sound is created and where the sound is heard. Additionally, if sound can be heard from within a house at night in a residential zone it may not be allowed. For more details, see TMC 8.22 District of Sound Producing Source District of Receiving Property Residential, Daytime* Residential, Nighttime Commercial Industrial Residential 55 dB(A) 45 dB(A) 57 dB(A) 60 dB(A) Commercial 57 dB(A) 47 dB(A) 60 d13(A) 65 dB(A) Industrial 60 dB(A) 50 dB(A) 65 dB(A) 70 dB(A) *Daytime means 7AM-1 OPM, Monday through Friday and 8AM-1 OPM, Saturday, Sunday and State -recognized holidays. A few sounds are exempt from the noise code, including: Warning devices; Construction and property maintenance during the daytime hours (7am-10pm); Testing of backup generators during the day. PERMIT APPLICATION NOTES - Value of construction — in all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the permit center to comply with current fee schedules. Expiration of plan review — applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The building official may grant one extension of time for additional periods not to exceed 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND 1 AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWER OR Signature: Print Name: Tom Reddy AGENT: Mailing Address: 1400 Airport Way South, Ste 202 Date: B ` 1 / I Day Telephone: (206) 604-1711. Seattle WA 98134 City State Zip H:UpplicationsWorms-Applications On Line\2016 Applications\Mechanical Permit Application Revised 1-4-16.doex Revised: January 2016 Page 2 of 2 bh DESCRIPTIONS ACC• QUANTITY PAID PermitTRAK $258.96 M16-0126 Address: 16040 CHRISTENSEN RD 205 Apn: 2523049039 $258.96 MECHANICAL $249.00 PERMIT ISSUANCE BASE FEE R000.322.100.00.00 0.00 $32.50 PERMIT FEE R000.322.100.00.00 0.00 $166.70 PLAN CHECK FEE R000.322.102.00.00 0.00 $49.80 TECHNOLOGY FEE $9.96 TECHNOLOGY FEE TOTAL FEES PAID .. R000.322.900.04.00 0.00 $9.96 $258.96 Date Paid: Monday, August 01, 2016 Paid By: THOMAS REDDY Pay Method: CREDIT CARD 01721G Printed: Monday, August 01, 2016 1:04 PM 1 of 1 �� SYSTEMS /� INSPECTION RECORD (i 0 Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350a,,,,,r7,d_lAl Project: / ITyp t InspectlorT-c,� / I C�'Q,Y Pi��� e14 I 1c.(( �/�r� a I* "` 6c - oSz'k I Approved per applicable codes. L A Corrections required prior to approval. COMMENTS: Inspector: Aht, Date: 19'14� REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. wfi '�r 1 AABC CERTIT717 00015 E. Main- 13047S.. 't Cushinwo. OR 74633 BeReme, IVA 93006 Phone: (910') 225-1660' Phone: %2S) 747-9356 Fa (913) 335-1687 Fax: (425) 641-5663 TEST rI-,ND Biil,AUNCE REPORT Proiezq: K�7 �NL� Loeatioz: V ,R V'y��✓ PLAZA &], &1 � 160y0 G�R�S7 �NS�N 1�bRD �S�I.165 2.O2i)0S�TyK►yLC{}�b✓A Architezi: En.cineer: Contractor:LINLTE D 5YSTf-MS LLL Project 4um.ber: This is to ceA-%Hy that Ea91e Test - Balance has balanced the 5 stenms described herein_ to d2ei- opdmumn perfortna-nca capabilities. The testing and balancing has been performed in asrordance with tate standard re-quiae:nent9 and procedures of the associated ALL Balance Council and the resWts of these tasi ars herein recorded. :associated Air Balance Council Certification dumber: 93-02-01 D ate: Test & Balance Engineer: Stephen D. Barites Form ;09010 W Q --- 0 We L� Project IK V -y f- NC. AMII �,- Date page Oi System _ VA-\/ - I, A, 3 , T , S AIR DISSII7IBUT11-DW 2 ESF S EEi Terminal I Room Terminal sign ' Test—FPM or CFM Fina{ [fit moer Number Type I. Size raciQr fpM CFM Test f Test 2 Test 3 FQM CFM VAVA p I Cr Iso So a � 10- C)a 1 a 350 IJD . 3 I O 1`-1'� .q77U SSS SyS_ ;i ,505 ILI pyo 13S ISO ! a _ VAv _ y k s 510 p ��v=5 _ iy'' g ' Soo Sao01 Remarks UVE-7 w 7 f LL- voc.0 M� naM ll I o��n1. Form *89044 i TWO Vale Project � y f- NL e system _-- Ufa V — & 117 PAIR DiSTR U T JON a EST SHED Terminal I Room Terminal Deen Ta-st--FPM or CFM Final --7 i�SumD8r Type'IJSizs ; uvicrs FPM CFM Tact f Test 2 Test 3 FFM CFM HVADer -� ' Q 1 n R 1 16", 0 135 ';N S NO 1� 0 l9 S 1445 110 150 X li E 9a 5D. d 3 E f� 6� 3 6S Sc� f C� 55 ° D 50 I �.� 1 �o 16b J Lfs I e )60— I f 135 '-'P 5 0I i -So �0 a lay u Y�L�T a go Remarlca , Four: #89"D U N ITE D SYSTEMS MECHANICAL ♦ HEATING & AIR CONDITIONING ♦ SE. ;E & MAINTENANCE ♦ CONTROLS ♦ ENERGY MANAGEMENT ♦ TEST, ADJUST & BALANCE ♦ ENERGY SAVINGS PROGRAMS John Lapham 1400 Airport Way South, #202 Seattle, WA 98134 October 6, 2011 1400 AIRPORT WAY SOUTH, SUITE 202 SEATTLE, WASHINGTON 98134 PHONE (206) 933-6036 FAX (206) 937-3084 Mr. Bill Rambo Permit Technician Tukwila Department of Community Development 6300 Southcenter Blvd, #100 Tukwila, WA 98188 RE: Correction letter #1 for permit #M16-0126 Dear Bill, This letter is in response to the correction letter referred to above. Responses are in order of correction notice items and are numbered as such. 1pa y10 rt,�ju�r�� Pyrlle.✓� 2. Code references now indicate the 2015 codes. �u� Un✓1Q,s'S�n Plan sheets that have been modified based on this review are being re -submitted along with this letter and any supporting documentation. The modified sheets are M-1, M-2. This concludes our response. Please feel free to contact me at 206-933-6036 if you have any questions regarding this document. Regards, John Lapham Project Engineer RECEIVED CITY OF TUKWILA AUG 17 2016 :HERMIT CENTER City of Tukwila Allan Ekberg, Mayor Department of Community Development Jack Pace, Director August 05, 2016 TOM REDDY 1400 AIRPORT WAY S SUITE 202 SEATTLE, WA 98134 RE: Correction Letter # 1 MECHANICAL Permit Application Number M16-0126 KEYENCE - 16040 CHRISTENSEN RD - SUITE 205 Dear TOM REDDY, This letter is to inform you of corrections that must be addressed before your development permit can be approved. All correction requests from each department must be addressed at the same time and reflected on your drawings. I have enclosed comments from the following departments: BUILDING - M DEPARTMENT: Allen Johannessen at 206-433-7163 if you have questions regarding these comments. (GENERAL NOTE) PLAN SUBMITTALS: (Min. size 1 l x 17 to maximum size of 24x36; all sheets shall be the same size. New revised plan sheets shall be the same size sheets as those previously submitted.) (If applicable) "STAMP AND SIGNATURES" "Every page of a plan set must contain the seal/stamp, signature of the licensee(s) who prepared or who had direct supervision over the preparation of the work, and date of signature. Specifications that are prepared by or under the direct supervision of a licensee shall contain the seal/stamp, signature of the licensee and the date of signature. If the "specifications" prepared by a licensee are a portion of a bound specification document that contains specifications other than that of an engineering or land surveying nature, the licensee need only seal/stamp that portion or portions of the documents for which the licensee is responsible." It shall not be required to have each page of "specifications" (calculations) to be stamped and signed; Front page only will be sufficient. (WAC 196-23-010 & 196-23-020) (BUILDING REVIEW NOTES) 1. Codes for compliance referenced in plan notes including Washington energy code duct insulation codes noted on the plan sheet refer to outdated 2012 codes. Provide revised plans to show compliance with the current 2015 codes and correct duct insulation code references per "2015" Washington State energy codes. Please address the comments above in an itemized format with applicable revised plans, specifications, and/or other documentation. The City requires that two_CZ) sets of revised plan pages, specifications and/or other documentation be resubmitted with the appropriate revision block. In order to better expedite your resubmittal, a 'Revision Submittal Sheet' must accompany every resubmittal. I have enclosed one for your convenience. Corrections/revisions must be made in person and will not be accepted through the mail or by a messenger service. If you have any questions, I can be reached at 206-431-3655. Sincerely, Bill Rambo Permit Technician File No. M16-0126 xmn c.,,.rL.,.., t— R....1 .... .-.1 Q..;*., 4 )nn - 7..1-41 Id7 G;. r nQ 199 m Di-- )n.< 121 2A7n – D.... 1/1K 42 7 2«c PERMIT COORD COPY PLAN REVIEW/ROUTING SLIP PERMIT NUMBER: M16-0126 DATE: 08/22/16 PROJECT NAME: KEYENCE SITE ADDRESS: 16040 CHRISTENSEN RD, STE 250 Original Plan Submittal Revision # before Permit Issued X Response to Correction Letter # 1 Revision # after Permit Issued DEPARTMENTS: rrww JUvW � • ' W Bui ing Division Fire Prevention ❑ Planning Division 11 Public Works ❑ Structural ❑ Permit Coordinator ❑ PRELIMINARY REVIEW: DATE: 08/23/16 Not Applicable ❑ Structural Review Required ❑ (no approval/review required) REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: Approved 07 Corrections Required ❑ (corrections entered in Reviews) Notation: REVIEWER'S INITIALS: DUE DATE: 09/20/16 Approved with Conditions d Denied ❑ (ie: Zoning Issues) DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: 12/18/2013 PERMIT COORD COPY PLAN REVIEW/ROUTING SLIP PERMIT NUMBER: M16-0126 DATE: 08/01/16 PROJECT NAME: KEYENCE SITE ADDRESS: 16040 CHRISTENSEN RD - SUITE 205 X Original Plan Submittal Response to Correction Letter # DEPARTMENTS: "BuldingDivision A-14 �)IA Fire Prevention Revision # before Permit Issued Revision # after Permit Issued Planning Division ❑ Public Works ❑ Structural ❑ Permit Coordinator PRELIMINARY REVIEW: DATE: 08/02/16 Not Applicable ❑ Structural Review Required ❑ (no approval/review required) REVIEWER'S INITIALS: APPROVALS OR CORRECTIONS: DATE: DUE DATE: 08/30/16 Approved ❑ Approved with Conditions ❑ Corrections Required & - Denied ❑ (corrections entered in Reviews) (ie: Zoning Issues) Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg W- Fire ❑ Ping ❑ PW ❑ Staff Initials: 12/18/2013 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Fax: 206-431-3665 Web site: http://www.ci.tukwila.wa.us REVISION SUBMITTAL Revision submittals must be submitted in person at the Permit Center. Revisions will not be accepted through the mail, fax, etc. Date: D l/ 7 (/ 6 ❑ Response to Incomplete Letter # Plan Check/Permit Number: M16-0126 ® Response to Correction Letter # 1 ❑ Revision # after Permit is Issued ❑ Revision requested by a City Building Inspector or Plans Examiner Project Name: Keyence Project Address: 16040 Christensen Rd —Suite 205 Contact Person: TOM R i Phone Number: C!-06) � 3 3 " 6 Summ/aryd of Revision: l^,r9GL� i^��Fi�Pi✓1.c2� Yf ow Sheet Number(s): t4 -1 RECEIVED "Cloud" or highlight all areas of revision including dat hof r ision CITY OF TUKWILA Received at the City of Tukwila Permit Center by: AUG 17. 2016 ❑ Entered in TRAKiT on PERMIT CENTER \applications\forms-applications on line\revision submittal Created: 8-13-2004 Revised: UNITED SYSTEMS MECHANICAT . LLC Page 1 of 2 Home Espanol Contact Search L&I A-% Index Help M} LST Safety & Health Claims & Insurance Workplace Rights Trades & Licensing (D Washington State Department of Labor & Industries UNITED SYSTEMS MECHANICAL LLC Owner or tradesperson Principals SARGEANT, LESLIE E, PRESIDENT GANGNES, TYLER JEFFREY, MEMBER LAPHAM, JOHN GORDON, MEMBER Doing business as UNITED SYSTEMS MECHANICAL LLC WA UBI No. 602 439 405 License 1400 AIRPORT WAY S #202 SEATTLE, WA 98134 206-933-6036 KING County Business type Corporation Verify the contractor's active registration / license / certification (depending on trade) and any past violations. Construction Contractor Active. ...................................................... . Meets current requirements. License specialties GENERAL License no. UNITESM962QA Effective — expiration 11/01/2004-11/01/2016 Bond ............ American States Insurance Co $12,000.00 Bond account no. 32s205383 Received by L&I Effective date 05/07/2012 04/20/2012 Expiration date Until Canceled Bond history I.ns.....u.race ..........n...... Scottsdale Ins Co $1,000,000.00 Policy no. BCS0032421 Received by L&I Effective date 10/30/2015 11/01/2015 Expiration date 11/01/2016 Insurance history Savings ................... No savings accounts during the previous 6 year period. Lawsuits against the bond or savings No lawsuits against the bond or savings accounts during the previous 6 year period. https:Hsecure.Ini.wa.gov/verify/Detail.aspx?UBI=602439405&LIC=UNITESM962QA&SAW= 8/31/2016 MECHANICAL ABBREVIATIONS A AMPS HZ HERTZ AC AIR CONDITIONING IBC INTERNATIONAL BUILDING CODE ACH AIR CHANGES PER HOUR ID INSIDE DIAMETER/DIMENSION ACT ACOUSTICAL TILE CEILING IMC INTERNATIONAL MECHANICAL CODE AD ACCESS DOOR IN INCHES ADD'L ADDITIONAL IN WG INCHES WATER GAUGE AFF ABOVE FINISHED FLOOR IPLV INTEGRATED PART LOAD VALUE AFG ABOVE FINISHED GRADE KW KILOWATTS AHU AIR HANDLING UNIT LAT LEAVING AIR TEMPERATURE ALUM ALUMINUM LB/LBS POUND/POUNDS AMP/AMPS AMPERAGE LD/LIN DIFF LINEAR DIFFUSER AP ACCESS PANEL LF/LIN FT LINEAL FOOT/FEET ARCH ARCHITECT LPG LIQUID PROPANE GAS BDD BACKDRAFT DAMPER LVG LEAVING BHP BRAKE HORSEPOWER LWG LOW WALL GRILLE BLDG BUILDING LWR LOW WALL REGISTER BOD BOTTOM OF DUCT LWT LEAVING WATER TEMPERATURE BOP BOTTOM OF PIPE MAX MAXIMUM BOT BOTTOM MAU MAKE UP AIR UNIT BTU BRITISH THERMAL UNIT MBH 1000 BRITISH THERMAL UNITS BTUH BRITISH THERMAL UNITS PER HOUR MCA MINIMUM CIRCUIT AMPACITY CAP CAPACITY MD MOTORIZED DAMPER CC CONTROLS CONTRACTOR MFR MANUFACTURER CD CONDENSATE DRAIN MISC MISCELLANEOUS CDWR CONDENSER WATER RETURN MIN MINIMUM CDWS CONDENSER WATER SUPPLY MT MOUNT CFM CUBIC FEET PER MINUTE MTD MOUNTED CHWR CHILLED WATER RETURN MUW MAKE-UP WATER CHWS CHILLED WATER SUPPLY N NEW CLG CEILING N/A NOT APPLICABLE COL COLUMN NC NORMALLY CLOSED CONC CONCRETE NG/NGAS NATURAL GAS COND CONDENSATE NIC NOT IN CONTRACT CONN CONNECT/CONNECTED/CONNECTION NO NORMALLY OPEN/NUMBER CONT CONTINUOUS/CONTINUATION OA/OSA OUTSIDE AIR CONTR CONTRACTOR OB OPPOSED BLADE COORD COORDINATE OBD OPPOSED BLADE DAMPER COP COEFFICIENT OF PERFORMANCE OD OUTSIDE DIAMETER/DIMENSION CT COOLING TOWER P PUMP CU CONDENSER UNIT PCF POUNDS PER CUBIC FOOT DB DUCTBOARD PD PRESSURE DROP DBA DECIBEL PH PHASE DDC DIRECT DIGITAL CONTROL POC POINT OF CONNECTION DEFL DEFLECTION PRESS PRESSURE DEG DEGREE/ DEGREES PSI POUNDS PER SQUARE INCH DIA DIAMETER PSIG POUNDS PER .SQUARE INCH GAUGE DMPR DAMPER QTY QUANITY DN DOWN R RELOCATE DWG DRAWING RA RETURN AIR E EXISTING RND ROUND EXH EXHAUST REF REFERENCE EA EACH REG REGISTER EAT ENTERING AIR TEMPERATURE REQ REQUIRED EC EGGCRATE GRILLE/END CAP/ELEC CONTRACTOR RESID RESIDENTIAL EER ENERGY EFFICIENT RATING RF RELIEF EF EXHAUST FAN RG RETURN GRILLE. EFF EFFICIENCY RPM REVOLUTIONS PER MINUTE EL ELEVATION S SUPPLY ELEC/ELECT ELECTRICAL/ELECTRIC SA SUPPLY AIR EMCS ENERGY MANAGEMENT CONTROL SYSTEM SD SMOKE DETECTOR ENT ENTERING SEER SEASONAL ENERGY EFFICIENCY RATING EQUIP EQUIPMENT SENS SENSIBLE ESP EXTERNAL STATIC PRESSURE SG SUPPLY GRILLE EWT ENTERING WATER TEMPERATURE SL SOUND LINED EXIST EXISTING SM SHEETMETAL F FAHRENHEIT SPEC SPECIFICATION FAC FIRE ALARM CONTRACTOR SP STATIC PRESSURE FD FIRE DAMPER SQ FT SQUARE FEET FF FINISHED FLOOR SWR SIDE WALL REGISTER FLA FULL LOAD AMPS SS STAINLESS STEEL FLEX FLEXIBLE STRUC STRUCTURAL FLR FLOOR TA TRANSFER AIR FOB FLAT ON BOTTOM TEMP TEMPERATURE/TEMPORARY FOS FLAT ON SIDE TBD TO BE DETERMINED FOT FLAT ON TOP TG TRANSFER GRILLE FP FIRE PROTECTION TQC TOP OF CONCRETE/CURB FPM FEET PER MINUTE TOD TOP OF DUCT FSD FIRE/SMOKE DAMPER TOS TOP OF STEEL/TOP OF SLAB FT FOOT/FEET TOT TOTAL FV FACE VELOCITY TSP TOTAL STATIC PRESSURE G GRILLE TSTAT THERMOSTAT GA GAUGE TYP TYPICAL GALV GALVANIZED UH UNIT HEATER GC GENERAL CONTRACTOR V VOLT GEN GENERAL VD VOLUME DAMPER . GPM GALLONS PER MINUTE VEL VELOCITY GR GRILLE VERT VERTICAL GRD GRILLE/REGISTER/DIFFUSER VFD VARIABLE FREQUENCY DRIVE GWB GYPSUM WALL BOARD VOL VOLUME HD HEAD WB WET BULB HORIZ HORIZONTAL WG WATER GAUGE HP HORSEPOWER W/ WITH HR HOUR W/0 WITHOUT HSPF HEATING SEASONAL PERFORMANCE FACTOR W/SF WATTS PER SQUARE FOOT HT HEIGHT WSEC WASHINGTON STATE ENERGY CODE HWTG HIGH WALL TRANSFER GRILLE HWR HOT WATER RETURN HWS HOT WATER SUPPLY HX HEAT EXCHANGER MIMIMUM HANGER SIZES FOR ROUND DUCT DIAMETER MAXIMUM SPACING WIRE DIAMETER ROD DIAMETER STRAP SIZE 10" 6r LESS 12' 1 @ 12 GA 1/4" 1" x 22 GA 11" TO 18" 12' 2@12 GA OR i@8GA 1/4" 1" x 22 GA 19" To 24" 12' 2 @ 10 GA 1/4" 1" x 22 GA 25" TO 36" 12' 2 @ 8 GA 3/8" 1" x 20 GA 37" TO 50" 12' n/a 2 @ 3/8" 1" x 20 GA 51" TO 60" 12' n/a 2 @ 3/8" 2 @ 1" x 18 GA 61" TO 84" 12' n/a 2 @ 3/8" 2 @ 1" x 16 GA PROJECT DATA MECHANICAL LEGEND 10X10 RECTANGULAR SUPPLY AIR DUCT - 10X10 TURNING UP OR TOWARD 10X10 t X RECTANGULAR SUPPLY A I R DUCT - 10X10 TURNING DOWN OR AWAY 10X10 RECTANGULAR EXHAUST OR RETURN AIR 10X10 DUCT - TURNING UP OR TOWARD 10X10.1,' RECTANGULAR EXHAUST OR RETURN AIR 1_2KL0_J__71 DUCT - TURNING DOWN OR AWAY � 100 �Q ROUND DUCT - TURNING UP OR TOWARD 100 r ROUND DUCT - TURNING DOWN OR AWAY 100. 0 i 100 FLATOVAL DUCT - TURNING UP OR (( TOWARD 100 ij FLATOVAL DUCT - TURNING DOWN OR AWAY 100 VOLUME DAMPER 10�}� TRANSITION TURNING VANES FLEXIBLE DUCT 1402 -SL I SOUNDLINED DUCT 14x12 -W WRAPPED DUCT 1402 -SMI BARE SHEETMETAL DUCT QT WALL MOUNTED THERMOSTAT co 5000 SQUARE FOOT RANGE CO SENSOR USE AIRTEST MODEL CT -1000 2 10000 SQUARE FOOT RANGE CO SENSOR USE CONSPEC MODEL P2621 FD O- 1.5 HOUR CURTAIN STYLE VERTICAL FIRE DAMPER 1.5 HFD C� 1,5 HOUR CURTAIN STYLE HORIZONTAL FIRE DAMPER FD 3 HOUR CURTAIN STYLE VERTICAL FIRE DAMPER HFD 3 HOUR CURTAIN STYLE HORIZONTAL FIRE DAMPER CFD 4® CEILING RADIATION DAMPER FS O®- 1.5.HOUR VERTICAL COMBINATION FIRE/SMOKE DAMPER 1.5 GRILLE ACCESS 1.5 HOUR VERTICAL COMBINATION D GAFIRE/SMOKE DAMPER HFSD 4- 1,5 HOUR HORIZONTAL COMBINATION FIRE/SMOKE DAMPER TESD 1.5 HOUR TUNNEL CORRIDOR COMBINATION FIRE/SMOKE DAMPER FSD 4-- 3 HOUR VERTICAL COMBINATION FIRE/SMOKE DAMPER 3 HFSD 0- 3 HOUR HORIZONTALCOMBINATION FIRE/SMOKE DAMPER 3 3 HOUR TUNNEL CORRIDOR COMBINATION FIRE/SMOKE TFSD G- DAMPER SD 41- VERTICAL SMOKE DAMPER MIMIMUM HANGER SIZES FOR RECTANGULAR DUCT - < C403.2.8.1 DUCts, Shafts and plenums conveying MAXIMUM PAIR @ 10' SPACING PAIR @ 8' SPACING PAIR @ V SPACING PAIR @ 4' SPACING building- eiivelo e. insulatioii're uirenients of Section g P,. q where located outside the building with a minimum C402, plus.building envelope vapor control _ .requirements Eton! the Iiiieriiatio mal B01ding Code. insulation in Climate Zone 5. -Where located within a extending continuously from the.building exterior to building envelope assetribly;' the duct or p enum shall HALF OF DUCT be separated froii the building exterior or equip! eni. For ilio purposes of building envelope unconditioned or exempt spaces by mititilluiii insulation requirements; duct surfaces shall meet the insulation value as required fol= exterior walls by requirements for metal fraiiied walls per; Table Section C402.1.3. C402J 4: Duct surfaces included as part of the PERIMETER STRAP WIRE/ROD STRAP WIRE/ROD STRAP WIRE/ROD STRAP WIRE/ROD P/2 = 30" 1" x 22 GA 10 GA 1" X 22 GA 10 GA 1" x 22 GA 12 GA 1" x 22 GA 12 GA P/2 = 72" 1" x 18 GA 3/8" 1" x 20 GA 1/4" 1" x 22 GA 1/4" 1" x 22 GA 1/4" P/2 = 96" 1" x 16 GA 3/8" 1" x 18 GA 3/8" 1" x 20 GA 3/8" 1" X 20 GA 3/8" P/2 =120" 1.5" x 16 GA 1/2" 1" x 16 GA 3/8" 1" x 18 GA 3/8" 1" x 18 GA: 3/8" P/2 =168" 1.5" X 16 GA 1/2" 1.5" x 16 GA 1/2" 1" X 16 GA 3/8" 1" x 16 GA 3/8" P/2 =192" NOT GIVEN 1/2" .1.5" X 16 GA 1/2" 1" x 16 GA 3/$" 1" x 16 GA 3/8" P/2 > 19Z" SPECIAL ANALYSIS REQUIRED WHEN STRAPS ARE LAP JOINED USE THESE MINIMUM SINGLE HANGER MAXIMUM ALLOWABLE LOAD IN LBS: FASTENERS STRAP WIRE OF ROD (DIA.) f 1. _- 1" x 22 GA i_ 260 0.106" 80 1" x 18, 20, 22 GA - TWO #10 OR ONE 1/4" BOLT 1" x 16 GA - TWO 1/4" DIA. 1" x 20 GA 320 0.135" 120 1.5" x 16 GA - TWO 3/8' DIA. I 1"x 18 GA __ 420 0162" 160 I 1" x 16 GA 700 1/4' 270 ._... ........ PLACE FASTENERS IN SERIES, NOT SIDE BY SIDE. ..... __.... ..- 1.5" x 22 GA �.. _ ........... . 1100 _..._._.._._.. .............. 3/8" _.......... 680 . . - - ._. 1/2.. ._....._.._.......__ 1250 _.._. __._.. --- - ._......... _ .._.. ..-_.__..._ .... _.._ .. _.._.............._....-"----- -------- ..__._... ___..... - 5/8" 2000 3/4" 3000 MECHANICAL GENERAL NOTES 1. ALL WORK SHALL CONFORM TO ALL APPLICABLE CODES AND REGULATIONS, INCLUDING, BUT NOT LIMITED TO THE 2015 IBC; 2015 WSEC, 2015 IMC. 2. DIMENSIONS ARE TO FACE OF STUD, CONCRETE, OR MASONRY UNLESS NOTED OTHERWISE. 3. DO NOT SCALE DRAWINGS, DIMENSIONS GOVERN. 4. VERIFY ALL EXISTING CONDITIONS, DIMENSIONS, DETAILS, ETC. NOTIFY ENGINEER OF ANY DISCREPANCIES PRIOR TO PROCEEDING WITH THE WORK: 5. WHEN CONSTRUCTION DETAILS ARE NOT SHOWN OR NOTED FOR ANY PART OF THE WORK DETAILS SHALL BE THE SAME AS FOR OTHER SIMILAR WORK. IF ADDITIONAL QUESTIONS REMAIN, CONTACT THE ENGINEER PRIOR TO PROCEEDING. 6. ALL STRUCTURAL OPENINGS AND PLATFORMS SHALL BE PROVIDED BY THE GENERAL CONTRACTOR UNLESS NOTED OTHERWISE. 7. DUCT SEALING AND CONSTRUCTION TO MEET SMACNA AND ENERGY CODE REQUIREMENTS. UNLESS OTHERWISE NOTED LOW PRESSURE DUCTWORK (DOWNSTREAM OF VAV BOXES, CONSTANT VOLUME AC SYSTEMS, TOILET EXHAUSTS, ETC.) TO MEET 2" CONSTRUCTION STANDARDS WITH SEAL CLASS C. MEDIUM PRESSURE DUCTWORK UPSTREAM OF VAV BOXES, HIGH VELOCITY EXHAUSTS, ETC.) TO MEET 4" CONSTRUCTION STANDARDS WITH SEAL CLAS A.. DUCT RISERS IN SHAFTS WITH DAMPERED PENETRATIONS TO MEET 6" CONSTRUCTION STANDARDS WITH SEAL CLASS A. 8. ALL CEILING DIFFUSERS ARE 4-4AY THROW UNLESS NOTED OTHERWISE. 9. ALL DUCT DIMENSIONS ARE CLEAR INSIDE DIMENSIONS AFTER LINING HAS BEEN INSTALLED. 10. OUTSIDE AIR INTAKES ON ALL AIR HANDLING UNITS SHALL BE 10 FEET AWAY FROM ANY FUEL BURNING EQUIPMENT, AND 10 FEET AWAY FROM, OR 3 FEET BELOW ANY PLUMBING VENT OR EXHAUST OUTLET. 11. ALL AIR ECONIMIZERS SHALL BE CAPABLE OF THE FOLLOWING: -0% TO 100% OF THE DESIGN SUPPLY AIR -CONTROLLED BY A CONTROL SYSTEM DETERMINING IF THE OUTSIDE AIR CAN MEET PART OR ALL OF.THE BUILDING COOLING LOADS. INTEGRATED TO PROVIDE PARTIAL COOLING EVEN WHEN MECHANICAL COOLING IS REQUIRED. 12. OUTSIDE AIR INTAKE, RELIEF, AN) EXHAUST OPENINGS SHALL BE EQUIPPED WITH MOTORIZED DAMPERS WHICH CLOSE AUTOMATICALLY WHEN SYSTEM IS CFF OR UPON POWER FAILURE, AS REQUIRED BY ENERGY CODE. 13. THE CONTROL SYSTEM SHALL BE 7 -)AY PROGRAMABLE, CAPABLE OF BEING SET FOR SEVEN (7) DIFFERENT DAY TYPES PER WEEK, AND CAPABLE OF A DEADBAND.SETTING OF AT LEAST 5 DEGREES F (10 F FOR RESIDENTIAL BETWEEN THE HEATING AND COOLING SETPOINTS. AHU CONTROL SYSTEM SHALL INCLUDE A MICROPROCESSOR AND BE CAPABLE OF ESETTING SUPPLY AIR TEMPERATURES BY REPRESENTATIVE BUILDING LOADS. 14, RECORD DRAWINGS OF THE ACTUAL INSTALLATION SHALL BE PROVIDED TO THE BUILDING OWNER WITHIN 90 DAYS OF THE DATE OF SYSTEM ACCEPTANCE PER THE WASHINGTON STATE ENERGY CODE. AN OPERATING MANUAL AND MAINTENANCE MANUAL .SHALL BE PROVIDED TO THE BUILDING OWNER. ALL HVAC SYSTEMS SHALL BE BALANCED AND A WRITTEN BALANCING REPORT SHALL BE PROVIDED TO THE OWNER. HVAC CONTROL SYSTEMS SHALL BE TESTED TO ENSURE THAT THEY OPERATE IN ACCORDANCE WITH SPECIFICATIONS AND APPROVED PLANS, A PRELIMINARY COMMISSIONING REPORT OF TEST PROCEDURES AND RESULTS SHALL BE PREPARED PRIOR TO ISSUANCE OF A FINAL CERTIFICATE OF OCCUPANCY. A COMPLETE FINAL COMMISSIONING REPORT OF TEST PROCEDURES AND RESULTS SHALL BE PROVIDED TO THE OWNER. COMMISSIONING, SYSTEM BALANCING, RECORD DRAWINGS AS REQUIRED PER THE WASHINGTON STATE ENERGY CODE. 15. MECHANICAL SYSTEMS SHALL COMPLY WITH SEISMIC RESTRAINT REQUIREMENTS OF THE BUILDING CODE SMACNA AND ASCE 7. ALL LIFE SAFETY HAZARDOUS MATERIAL RELATED SYSTEMS SHALL BE DEEMED AN Ip =1.5 FOR RESTRAINT METHODS OR AS NOTED ON THE DRAWINGS. REFER TO THE ABOVE NOTED CODES FOR INSTALLATION REQUIREMENTS AND EXCEPTIONS BASED ON SIZING, WEIGHTS AND MOUNTING HEIGHTS, 16. PROVIDE EARTHQUAKE RESTRAINTS FOR HVAC EQUIPMENT AS REQUIRED BY SMACNA SEISMIC RESTRAINT MANUAL, SEIZMIC HAZARD B. WIRES FOR CEILING SYSTEM ETC. SHALL NOT BE HUNG OFF HVAC EQUIPMENT OR HVAC EQUIPMENT SUPPORTS, 17. PROVIDE FIRE AND COMBINATION FIRE/SMOKE DAMPERS WHERE SHOWN ON PLANS AND WHERE REQUIRED PER CODE. 18. ALL PIPING PENETRATIONS THROUGH RATED ASSEMBLIES SHALL BE SEALED WITH A UL APPROVED FIRE CAULKING. 19. SMOKE DETECTORS PROVIDING AUTOVATIC SHUTDOWN SHALL BE PROVIDED FOR HVAC EQUIPMENT DELIVERING IN EXCESS OF 2000 CFM [INCLUDING MULTIPLE UNITS DUCTED INTO COMMON DISTRIBUTION OR RETURN, WITH AN AGGREGATE SUPPLY GREATER THAN 2000 CFM1 OR EACH STORY CF RETURN SYSTEMS OVER 15 000 CFM IN A MULTI -STORY INSTALLATION PER CODE. SMOKE DETECTOKKS SHALL BE FURNISHED AND NSTALLED BY ELE6TRICAL CONTRACTOR UNLESS NOTED OTHERWISE. POWER -WIRING AND INTERLOCK TO FIRE ALARM SYSTEM BY ELECTRICAL CONTRACTOR AS APPLICABLE. 20. ACCESS PANELS SHALL BE PROVIDED AND INSTALLED BY GENERAL CONTRACTOR. 21. ALL MOTOR STARTERS NOT SHOWN IN EQUIPMENT SCHEDULES SHALL BE FURNISHED AND INSTALLED BY ELECTRICAL CONTRACTOR. 22. FOR ALL "SEALED AIR TIGHT"•SHAFTS OR ROOMS THE FOLLOWING SHALL OCCUR: ALL VERTICAL JOINTS INSIDE .THE SHAFT SHALL BE PROVIDED WITH A CONTINUOUS SEAL FOR THE LENGTH OF THE JOINT, INCLUDING SHAFT CORNERS GC) -TOPANDBOTTOMWALL TRACKSSHOULD BE CAULKED ALONG THEIR ENTIRE LENGTH(BY GCG) -ANY PENETRATIONSGOFETHENSHAFTAR TO THE CONSTRUCTIONFT SHALL (DUCTWORK, CONDUITT,CAULKED (PIPINBY G, FIL>ISHALLTBEROCK SEALEDWOOL ONIBOTHNOT SIDESPTABLE OF THE PENETRATION. -USE SECTION 909.5 OF THE 2012 IBC FOR MAXIMUM ALLOWABLE LEAKAGE AREA, FOLLOWING THE GUIDELINES FOR TIGHT STAIR SHAFT CONSTRUCTION. -ALL DOORS SHALL BE PROVIDED WITH TIGHT FITTING GASKETS, AND OPEN AGAINST THE DIRECTION OF ROOWSHAFT PRESSURE, 23, MAXIMUM LENGTH OF FLEXIBLE DUCT SHALL BE 12 FEET. REFER TO INSTALLATION DETAILS FOR SUPPORT REQUIREMENTS, FLEXIBLE DUCT FLAME SPREAD RATING SHALL BE < 25 AND SMOKE DEVELOPED RATING SHALL BE < 50. USE FLEXIDUCT MODEL G -KM FOR LOW AND MEDIUM PRESSURE APPLICATIONS OR APPROVED EQUAL. INSULATE DUCT PER NOTE 11 ABOVE, 24. LOCATION AND DETAILS OF EQUIPMENT, DUCT ROUTING AND CONNECTIONS ARE APPROXIMATE, COORDINATE FINAL LOCATIONS WITH OTHER TRADES. INSTALL IN ACCORDANCE WITH APPROVED SUBMITTALS AND DETAIL DRAWINGS WHEN APPLICABLE. SEPARATE PERMIT REQUIRED FOR: 0 Mechanical dElectrica) ,Plumbing Gas Piping city of Tukwila REVISIONS _ No changes shall be made to the scope of work without prior approval of Tukwila Building Division. MOTE: Revisions will require a new plan submittal and may include additional plan review fees. Plan review approval is subject to errors and omission Approval of construction documents does not author 2 the violation of any adopted code or ordinance. Regi of approved Field Copy and conditions is acknowledg c- By: __?)� ILIx / Bate: % �l City of Tukwila BUILDING DIVISION 2015 WSEC DUCT INSULATION REQUIREMENTS C403.2.8 Duct and. plenutii ins ilatio>tI and sealing. - < C403.2.8.1 DUCts, Shafts and plenums conveying C403.2.8.2 All other supply and return air ducts and ' outside air from the exterior of.the building to the plenums shall be insulated with a minimum of R=6 ' tnechanical system shall meet all air leakage and insulation where located in Dliconditioi ed spaces and building- eiivelo e. insulatioii're uirenients of Section g P,. q where located outside the building with a minimum C402, plus.building envelope vapor control of R-8 hisulation in Climate Zone 4 and R42 .requirements Eton! the Iiiieriiatio mal B01ding Code. insulation in Climate Zone 5. -Where located within a extending continuously from the.building exterior to building envelope assetribly;' the duct or p enum shall an automatic S11L1tOffda111 er or heating.Or cooling": be separated froii the building exterior or equip! eni. For ilio purposes of building envelope unconditioned or exempt spaces by mititilluiii insulation requirements; duct surfaces shall meet the insulation value as required fol= exterior walls by requirements for metal fraiiied walls per; Table Section C402.1.3. C402J 4: Duct surfaces included as part of the Exceptions. building etwelap6 shall riot be used in the calculation 1. Whore located within c iii t11C1lt: q p of maximum glazing area as described in Section C402:4: 1. 2: Where the design temperature difference - beV W*een the ulterior and exterior of the duct . Exceptions: or plenum does not exceed 15°F (8°C). 1 Outside air ducts serving individual supply �. Where located wtthin conditioned space; supply air units with less than 2,800 cf1t1 of total supply air ca aci provided these are pP y p t'' ducts which conveysupply air at temperatures less pp Y p - insulated to R-7 than 55°F or greater than 105°F shall be insulated With a minimum of R=3:3 insulation. 2. Unheated ec ui ricent rooms with l p ` _ . Exception: Ductwork exposed to view within a coinbustion air louvers provided they are ' p. y - zone that serves that zone is not required to be isolated from conditioned space at sides, lop insulated. and bottoin of the room with R-1 l nominal insulation. All ducts, air Handlers, and filter boxes shall be sealed. Joints and seailis "81!811 cottiply With Section 603.9 of the Inteilhational Meehan ical .Code. L,....C. 'S UK�`,Yv I Nc;:� ARE 1 HE I-12UI EF; I r Uf UIJ I i LU SYS � 1 CMS AfE(.I I,aI,I I CAL LL.(, ,_Sl�i,i ,._ U �r�ILIX. LLC. AND h�IJ51 tdUT BE REPRODUCED, , AL I EkEO UF2 USED V� I 1 HOU t [ I IL F R I Uk 4YR I t I LN �,t, I I L,It I ( i OF Ur•I I Fk DkAlvVliiL".; ,..� S, _l:i[ IIlE�C UFa,ti. :,: ARE 10 6E US.D ..,.L: A� :.:i ._'_1.i_n i iCI f i_ i,.....II L1, __ ADDRESS OF PROJECT 16040 CHRISTENSEN ROAD TUKWILA, WASHINGTON 98188 ASSESSORS PARCEL NUMBER 252304-9039 LEGAL DISCRIPTION POR W H GILLIAM D C NO 40 & OF SW 1/4 OF SW 1/4 OF SEC 24-23-04 & OF GL 1 OF SEC 25-23-04.DAF - COMM NW COR OF PARCEL 2 OF CITY OF TUKWILA SHORT PLAT NO 78 -16 -SS RECORDING NO 7906050098 TH S 64-09-52 E 24.88 FT TAP OF CURVE TH ELY 168 FT ALG ARC OF TANGENT CURVE TO LFT RAD 935 FT.THRU C/A 10-17-42 TO TPOB TH CONTG ELY 146.87 FT ALG ARC OF NON TANGENT CURVE TO LFT RAD 935 FT TH RADIUS PT BEARING N 15-32-26 E THRU C/A OF 09-00-01 TAP ON SD CURVE TH N 06-34-56 E 66.28 FT TAP OF CURVE TH NELY 6.86 FT ALG ARC OF NON TANGENT CURVE TO RGT RAD 62 FT RADIUS PT BEARING S 22-03-30 E THRU C/A OF 06-20-30 TAP OF REV CURVE TH NELY 25.15 FT ALG ARC OF TANGENT CURVE TO LFT RAD 20 FT THRU C/A 72-03-23 TAP OF TANGENCY TH N 02-13-37 E..99 FT TH S 87=46-23 E 6.67 FT TH N 02-13-37 E 106.77 FT TH N 71-04-07 E 51,22 FT TH N 48-35-00 E. 60.21 FT TH S 89-47-00 E 110 FT TH N 48-19-41 E 55 FT TH S 41-40-19 E 48.19 FT TH S 29-47-54 E 49.69 FT TH S 03-44-56 W 40.48 FT TH S 24-03-53 W 48.37 .FT TH S 39-19-22 W 62.85 FT TH S 32-31-34 .W 59.80 FT TH S 35-18-26 W 59.79 FT TH S 39-40-01 W 63.82 FT TH S 40-00-29 W 66.84 FT TH S 29-07-34 W 35.76 FT TH S 31-16-45 W 11.29 FT TH N 77-25-04 W 105.59 FT TH N 12-34-56 E 28 FT TH N 77-25-04 W 30.59 FT TAP OF CURVE TH SWLY 52.96 FT ALG ARC OF NON TANGENT CURVE TO RGT RAD 320 FT RADIUS PT BEARING N 69-42-59 W THRU C/A 09-28-59 TAP OF TANGENCY TH S 29-46-00 W 49.36 FT TH N 60-14-00 W 17.19 FT TH S 89-46-00 W 24.61 FT TH S 00-14-00,E 8.50 FT TH S 89-46-00 W 29.50 FT TH N 00-14-00 W 144.50 FT TH S 89-46-00 W 29.50 FT TH N 00-14-00 W 34 FT TH N 16-05-55 E 20.97 FT TAP OF CURVE TH SELY 9.43 FT ALG ARC OF NON TANGENT CURVE TO LFT RAD 968.50. FT RADIUS PT BEARING N 16-05-55 E THRU C/A 00-33-29 TAP ON SD CURVE TH N 15-32-26 E 33.50 FT TO TPOB LESS POR LY WITHIN 30 FT. CITY OF SEATTLE P L R/W - AKA REVISED LOT 1 OF CITY OF TUKWILA BDRY LN ADJ NO 81-40 BLA RECORDING NO 8112160540 REVISING CITY OF TUKWILA BDRY LN ADJ NO 81-1 BLA RECORDING NO 8102050389 VICINITY MAP SITE MAP • CORMOT N LTR# U N ITED SYSTEMS LW MECHAN I CALL L LC A FULL SERVICE COMMERCIAL HVAC CONTRACTOR 1400 AIRPORT WAY SOUTH SUITE 202 SEATTLE, WASHINGTON 98134 (206)933-6036/FAX 937-3084 REVISIONS DATE DISCRIPTION_ _ 8-15=-16 UPDATED PER CITY PLAN REVIEW. 1 N J o. O Z L z O_ z:00 ~ W N I_Wz z (,V � 0 0 Z ® OW V) z N =0 � W (� W 0 W O W W OO H= Y 0- V) ♦- FILE NAME : K -M PROJECT ENGINEER : JGL DATE REVISED :8-16-2016 JOB NUMBER :9460 SHEET NUMBER DPD STAMP ii CElVED CITY OF i'l.lKWILA AU33 17 2016 :yERMIi CENTER NOTES: 1. EXISTING RE-HEATVAV BOX. 0�3 010 okl UNITED VAV TERMINAL BOX SCHEDULE USI' MF='CH^N I CAL UNIT ID AREA OF SERVICE MAKE. & MODEL INLET SIZE VALVE CFM. MAX MIN KW HEATER CFM VOLT/PH NOTES VAV- 1 SUITE 202 TEMPMASTER S5 6 .9`10 90 N/A 650 NIA VAV-2 SUITE 202 TEMPMASTER S5 N/A 505 50 N/A 505 NIA VAV-3 OVAV-54 SUITE 205 U TEMPMASTER S5 N/A 405 40 N/A .405 N/A. DATE- DISCRIPTION VAV-4 SUITE 205 TEMPMASTER S5 10 525 50 N/A 525 N/A i SUITE 205 TEMPMASTER S5 a 500 50 NIA 500 N/A 1 VAV-6 SUITE 205. TEMPMASTER S5 6 605 60 3.9 605 27711 1 VAV- 7 SUITE 205 TEMPMASTER S5 12 985 90 NA 700 N/A I 0 0 NOTES: 1. EXISTING RE-HEATVAV BOX. 0�3 010 okl UNITED SYSTEMS USI' MF='CH^N I CAL L. LC A FULL SERVICE COMMERCIAL HVAC CONTRACTOR 1400 AIRPORT WAY SOUTH SUITE 202 SEATTLE WASHINGTON 98134 (206)933-6036/FAX 937-3084 REVISIONS DATE- DISCRIPTION r. cl .j N 0 0 ry LO 00 7- W LLJ V) w z a Z > - N < W o elf 0 -T7 0 3i >- W -1 0 LL- *z: � g W > 0 (-) t (/) LLI 0 (D FILE NAME :K—M PROJECT ENGINEER :JGL DATE REVISED -, 8-16-2016 JOB NUMBER :9460 SHEET NUMBER M�2 DPD STAMP V E, D TUMILA AUS' 11 2016 om, ff/ -ERMI I'GENTER