Loading...
HomeMy WebLinkAboutPermit M16-0136 - PACIFIC NW IRON WORKERS - ROOFTOP GAS PACKAGED A/C UNITSPNWIRONWORKERS 4550 S 134 PL M16-0136 } City of Tukwila • Department of Community Development • 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Inspection Request Line: 206-438-9350 Web site: http://www.TukwilaWA.gov MECHANICAL PERMIT Parcel No: 2613200005 Permit Number: M16-0136 Address: 4550 S 134TH PL COMPLEX Issue Date: 9/15/2016 Permit Expires On: 3/14/2017 Project Name: PNW IRON WORKERS Owner: Name: PACIFIC NW IRONWORKERS&EMPL Address: 701 FIFTH AVE STE 2200 ATT:MILT Address: Phone: (206) 250-4530 Phone: (206) 248-9700 Expiration Date: 9/3/2017 DESCRIPTION OF WORK: INSTALL (3) ROOFTOP GAS PACKAGED AC UNITS W/ECONOMIZER, DUCTWORK, GIRDS & THERMOSTATS. RELOCATE (1) GAS FIRE UNIT HEATER AND (1) EXISTING DIFFUSER. ASSOCIATED GAS PIPING. INSTALL (1) CELING TRANSFER FAN Valuation of Work: $50,000.00 Type of Work: REPLACEMENT Fuel type: GAS Fees Collected: $846.88 Electrical Service Provided by: SEATTLE CITY LIGHT Water District: 125 Sewer District: TUKWILA Current Codes adopted by the City of Tukwila: International Building Code Edition: SMITH, SEATTLE, WA, 98104 Contact Person: 2014 Name: CONNIE HARDIN Address: 4600 S 134 PL, SEATTLE, WA, 98168 Contractor: 2015 Name: HOLADAY PARKS INC Address: 4600 S 134 PL, SEATTLE, WA, 98168 License No: HOLADPI379NO Lender: 2015 Name: Address: Phone: (206) 250-4530 Phone: (206) 248-9700 Expiration Date: 9/3/2017 DESCRIPTION OF WORK: INSTALL (3) ROOFTOP GAS PACKAGED AC UNITS W/ECONOMIZER, DUCTWORK, GIRDS & THERMOSTATS. RELOCATE (1) GAS FIRE UNIT HEATER AND (1) EXISTING DIFFUSER. ASSOCIATED GAS PIPING. INSTALL (1) CELING TRANSFER FAN Valuation of Work: $50,000.00 Type of Work: REPLACEMENT Fuel type: GAS Fees Collected: $846.88 Electrical Service Provided by: SEATTLE CITY LIGHT Water District: 125 Sewer District: TUKWILA Current Codes adopted by the City of Tukwila: International Building Code Edition: 2015 National Electrical Code: 2014 International Residential Code Edition: 2015 WA Cities Electrical Code: 2014 International Mechanical Code Edition: 2015 WAC 296-468: 2014 Uniform Plumbing Code Edition: 2015 WA State Energy Code: 2015 International Fuel Gas Code: 2015 Permit Center Authorized Signature: Date: , 1,5 I hearby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this development per it and agree to th cond :tions attached to this permit. A Signature: Date: I _- Print Name: This permit shall become null and void iMe work is not cb9menced withinki8q days for the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last in ection. PERMIT CONDITIONS: 1: Work shall be installed in accordance with the approved construction documents, and any changes made during construction that are not in accordance with the approved construction documents shall be resubmitted for approval. 2: All permits, inspection record card and approved construction documents shall be kept at the site of work and shall be open to inspection by the Building Inspector until final inspection approval is granted. 3: Readily accessible access to roof mounted equipment is required. 4: All construction shall be done in conformance with the Washington State Building Code and the Washington State Energy Code. 5: Remove all demolition rubble and loose miscellaneous material from lot or parcel of ground, properly cap the sanitary sewer connections, and properly fill or otherwise protect all basements, cellars, septic tanks, wells, and other excavations. Final inspection approval will be determined by the building inspector based on satisfactory completion of this requirement. 6: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206-431-3670). 7: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center. 8: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. 9: `MECHANICAL PERMIT CONDITIONS' 10: All mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center (206/431-3670). 11: Manufacturers installation instructions shall be available on the job site at the time of inspection. PERMIT INSPECTIONS REQUIRED Permit Inspection Line: (206) 438-9350 0703 MECH EQUIP EFF 1800 MECHANICAL FINAL 0609 PIPE/DUCT INSULATION 0705 REFRIGERATION EQUIP 0701 ROUGH -IN MECHANICAL V CITY OF TUKR--A Community Development Department Permit Center • 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 hgp://www.TukwilaWA.g_oo_v Mechanical Permit No. Project No. Date Application Accepted: _ Date Application Expires: or office use ons) MECHANICAL PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. **please print** SITE LOCATION �__-,. _ W 194 King Co Assessor's Tax No.: Z1370 [l W5--" Site Ad Tenant CONTACT PERSON — person receiving all project communication Name: _ — - 11 __ , Address: City: Email: Suite Number: Floor: New Tenant: ❑ .....Yes Q- o MECHANICAL CONTRACTOR INFORMATION Company Name: &�)� la -1, /--�/ Address:�. City: State: • Zi . Phon. ax:. Z .701 Contr Reg No Date: —a;40 Tukwila Business License No.: Valuation of project (contractor's bid price): $ Describe the scope of work in detail: 6-3) qCLS " -- qes Use: Residential: New .......... ❑ Replacement ........ ❑ Commercial: New .......... ❑ Replacement ........ ❑'— Fuel Type: Electric..... ❑ Gas ....... 9-1, Other: H:\Applications\Forms-Applications On Line\2016 Applications\Mechanical Permit Application Revised 14-16.doc Revised: January 2016 Page 1 of 2 bh J Indicate type of mechanical work being installed and the quantity below: Unit Type Qty Furnace <100k btu Residential Nighttime Furnace >100k btu Industrial Floor furnace 55 dB(A) Suspended/wall/floor mounted heater 57 dB(A) Appliance vent Commercial Repair or addition to heat/refrig/cooling system 47 dB(A) Air handling unit <10,000 cfin 3 Unit Type Qty Air handling unit >10,000 cfrn Residential Nighttime Evaporator cooler Industrial Ventilation fan connected to single duct 55 dB(A) Ventilation system 57 dB(A) Hood and duct Commercial Incinerator - domestic 47 dB(A) Incinerator - comm/industrial 3 Unit Type Qty Fire damper Residential Nighttime Diffuser Industrial Thermostat 55 dB(A) Wood/gas stove 57 dB(A) Emergency enerator Commercial Other mechanical equipment 47 dB(A) 60 dB(A) 3 Boiler/Compressor Qty 0-3 hp/100,000 btu Residential Nighttime 3-15 hp/500,000 btu Industrial 15-30 hp/1,000,000 btu 55 dB(A) 30-50 hp/l ,750,000 btu 57 dB(A) 50+ hp/1,750,000 btu Commercial 57 dB(A) 47 dB(A) 60 dB(A) 65 dB(A) Noise: Mechanical units need to be in compliance with the Tukwila Noise Code. Maximum permissible sound levels are based on from where the sound is created and where the sound is heard. Additionally, if sound can be heard from within a house at night in a residential zone it may not be allowed. For more details, see TMC 8.22 District of Sound Producing Source District of Receiving Property Residential, Daytime* Residential Nighttime Commercial Industrial Residential 55 dB(A) 45 dB(A) 57 dB(A) 60 dB(A) Commercial 57 dB(A) 47 dB(A) 60 dB(A) 65 dB(A) Industrial 60 dB(A) 50 dB(A) 65 dB(A) 70 dB(A) *Daytime means 7AM-1 OPM, Monday through Friday and 8AM-IOPM, Saturday, Sunday and State -recognized holidays. A few sounds are exempt from the noise code, including: Warning devices; Construction and property maintenance during the daytime hours (lam-IOpm); Testing of backup generators during the day. PERMIT APPLICATION NOTES - Value of construction - in all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the permit center to comply with current fee schedules. Expiration of plan review - applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The building official may grant one extension of time for additional periods not to exceed 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. Day Telephone M'9 ZZ LI's-3c ) City State Zip H:\Applications\Fomrs-Applications On Lme\2016 Applications\Mechanical Permit Application Revised 1-4-16.doex Revised: January 2016 Page 2 of 2 bh DESCRIPTIONS PermitTRAK PAID $846.88 M16-0136 Address: 4550 S 134TH PL COMPLEX Apn: 2613200005 $846.88 MECHANICAL $814.31 PERMIT ISSUANCE BASE FEE R000.322.100.00.00 0.00 $32.50 PERMIT FEE R000.322.100.00.00 0.00 $618.95 PLAN CHECK FEE R000.322.102.00.00 0.00 $162.86 TECHNOLOGY FEE $32.57 TECHNOLOGY FEE TOTAL FEES PAID BY RECEIPT: R9320 R000.322.900.04.00 0.00 $32.57 $846.88 Date Paid: Thursday, September 01, 2016 Paid By: CONNIE HARDIN Pay Method: CREDIT CARD 06134G Printed: Thursday, September 01, 2016 11:56 AM 1 of 1 WrV SYSTEMS INSPECTION RECORD Retain a copy with permit'����� INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-367 Permit Inspection Request Line (206) 438-9350 Project: i ufaA►elc �t2S Ty a of Inspection: L rn!' Address: 4 yM S 1,Sg714 pi, Date Called: Special Instructions: A Date Wanted: '7 /7 p.m. Requester: Phone No: Approved per applicable codes. E Corrections required prior to approval. COMMENTS: Inspector: Date: REINSPECTION FEE REQUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd.. Suite 100. Galt to schedule reinspection. INSPECTION RECORD Retain a copy with permit /6 -0 INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Proje t: ,�? i �U �e TypegNftspection: ✓✓ 14c— ddress• l 3u 171 L Date Called: Special Instructions: Date Want a.m. Requester Phone No: t� Approved per applicable codes. ElCorrectionsrequired prior to approval. Inspector:A&n I Date, jkelp L�t U REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Proj ct: 7*A/ 12 Type of Inspection: L04AA)) 64L'%k1A4 Address: sw S T), PL Date Called: Special Instructions: Date Wanted: m. l� 6 Requester: Phone No: Approved per applicable codes.Corrections required prior to approval. LJ paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. INSPECTION RECORD[70 1 K4 16 Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 9lP1A)j;, P 'ect: Ty a of Inspection: AL I Address: cJs S 13q 174 P1, Date Called: Special Instructions: Date Want a.m. ��. �(� p.m. IlRequest&: Phone No: ® Approved per applicable codes. 11 Corrections required prior to approval. Inspector Date /Z%� r REINSPECTION FEE REQUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. a �INSPECTION RECORD Retain a copy with permitFm j 36 I INSP OffMN N0. PERMIT N0. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Project: !'�/Af &A/ Ty a of Inspection: Address: SS"Z� S 30 771 21. Date Called: Special Instructions: Date Wanted* / a. 1 � /6 P.m. Requeste : Phone No: 21 Approved per applicable codes. 1 Corrections required prior to approval. Inspector Date: El REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. Air System Sizing Summary for RTU -210A Project Name: Iron Workers Union 08/23/2016 Prepared by: Holada -Parks 03:13PM Air System Information Air System Name: ................. . .......... ...._..______.RTU -210A Number of zones: .......... -................... -.......................... .._..- 1 Air System Type: ._... ................... ............Single Zone CAV Floor Area:.---....- ... _................. _................. ................. ---.....920.0 sqft Location: ........... ___ ..... ..___.......... Seattle IAP, Washington Sizing Calculation Information Calculation Months: ...... Jan to Dec Central Cooling Coil Sizing Data Total coil load:.. ................. __ ...... - ........... ............................. 2.3 Tons Total coil load:..-_.__ ........................... ... ___.._.____..---....2T.Q MBH Sensible coil load: ............... -............................... ..._.._.......22.5 MBH Coil airflow:...._ .................................. CFM Sensible heat ratio:_... Area per unit load:._.__.......................................................408.3 sgftrron Load per unit area: ............... .......... . . ............... 20.4 BTU/(hr-sqft) Central Heating Coil Sizing Data Max coil load: ......................... ................. ................ . .. __38.5 MBH Coil airflow: ................. .............................. __.____..........1008 CFM Load per unit area: .................... ......... 41.9 BTU/(hr-sqft) Supply Fan Sizing Data Actual max airflow: ... _.__.................. Standard airflow: .................... . . ....... Actual max airflow per unit area: Calculation method:.._. -.__...Transfer Function Method Load occurs at:--...-. ........ .___............... _...._....-.....Aug 1500 OADB / WB: .... _ ...... . .. . ............................... . .......... _85.0/65.0 F Entering DB / WB: ...---- _.....-._....__- ............... ..........77.8/64.7 F Leaving DB / WB:...__ ..... _.................... _.............. _..56.8/55.6 F CoilADP:.- ................._........- — - ._......... _....... ........... _54.5 F Bypass Factor:. ........ _................ .... ............... .........•......0.100 Resulting RH:.........._....-- -- ........_.... - - ...... ................60 % Design supply temp: ----- - ------- ------- ........... ...... _...... .__...... 56.5 F Load occurs at; ..............-----.......- .Des Htg Ent DB / Lvg DB: .-..--.------- ............_...._._.........._.----54.4/90.3 F .1008 CFM Fan motor BHP:..._. ... -_..... _........... -.._ ...............................D.44 BHP ..991 CFM Fan motor kW: ......... ... . . . ....... . ..................................... 0.33 kW .1.10 CFM/sqft Fan static:._. ........... -.............. .---- ----------------------------------------- ..1.50 in wg Outdoor Ventilation Air Data Design airflow:...._ ........................ - ...... ---....... ......- - ...332 CFM Airflow per unit floor area:. ............ . . . ........... .-0.36 CFM/sqft Space Sizing Data Airflow per person:. Space Name i Maximum Design Time of Peak Maximum Space Space Cooling; Airflows _ Load Heating Floor CFM/sgft Sens, lie CFM ± Load MBHi Aroaj MBHiscift4 Corridor 13.41 1841 Jul 15001 3.9 260.0 0.71 Training 210A 115.3 825 Jul 1600 19,6 660.0 1.25 Zone - -1 1008.1 Jul 1600 .1 23.5 .1 920.0! 1.10 Note: Table contains data for all spaces controlled by a single thermostat: Space sizing basis: ......... _.----.Peak space load Zone sizing basis: ................ . ..... Peak zone load REVIEWED FOR ODE COMPLIANCE {-- ' APPROVED ~; SEP 13 2016 w of TuWA(a BUILDING DIMSIM CFM/person RE_ CE1VE0 CITY OF TUKWILA SEP 0 1 20% PERMIT CENTER System Design Load Summary for RTU -21 OA Project Name: Iron Workers Union 08/23/2016 Prepared by: Holada -Parks 03:13PM Block Load 4.15 Page 2 of 3 DESIGN COOLING DESIGN HEATING Aug 1500 Design Heating Day OADBiWB85F185F Zone Loads based on TFM �;- DetaiWl Sensible Latent BTU/hr BTU/hr. . _OADBIWB23F119.2F Details_ Sensible Latent BT I r BTU/hr, l Window and Skylight Solar Loads 0 sqft 0 0 sgft - _ Wall Transmission 310 sqft 74 310 sqft 1821 - Roof Transmission 0 sqft 0 0 sqft 0 - Window Transmission 0 sqft 0 0 sqft 0 Skylight Transmission 0 sqft 0 0 sqft 0 Door Loads 0 sqft 0 - 0 sqft 0 Floor Transmission 820 sqft 0 820 sqft 0 - Partitions/Ceilings 2200 sqft 764 - 2200 sqft 18600 Overhead Lighting 1380 W 4303 - 0 W 0 Electric Equipment 1120W 3685 - 0 W 0 People 36 8021 7120 0 Q p Infiltration 0 0 - 0 0 Miscellaneous 0 0 - 0 0 Safety Factor 10%/10% 1685 712 150/0 3063 0 >>Total Zone. Loads 18531 .78321 23484; 0 Thermostat and Pulldown Adjustment -953 Q _308 0 Plenum Wall Load 0% 0 0 0 - Plenum Roof Load 0% 0 - p 0 _ Plenum Lighting Load 0% 0 0 0 Ventilation Load 332 CFM 3785 -3279 332 CFM 16461 0 Supply Fan Load 1008 CFM 1120 1008 CFM -1120 >> Total System Loads 22483 .45531 38517 0 Central Cooling Coil - 224931 4554 01 0 Central Heating Coil 0 - - 38517 >> Total Coil Loads Key: 224831 Positive values are clg loads Negative values are htg loads 4554 I 38517 Positive values are htg loads Negative values are clg loads _ 0 i Block Load 4.15 Page 2 of 3 t Air System Sizing Summary for RTU -2108 Project Name: Iron Workers Union 08/23/2016 Prepared b Holada -Parks 03:17PM Air System Information Air System Name: ................. . ................. _.____RTU -210B Number of zones: .._-----.... -.............................................. .....1 Air System Type: .................. ...._....... Single Zone CAV Floor Area:._.._._-.._...__.. .............. .._..____......._____....._.._.860.0 sqft Location: .... ._...... ................... __..Seattle IAP, Washington Sizing Calculation Information Calculation Months: -------- ...................... .................Jan to Dec Central Cooling Coil Sizing Data Total coil load:._...............__._._.___............_.._............._..........2.1 Tons Total coil load: ........... _............. ... _............ ... .............. ..25.8 MBH Sensible coil load: .................................... . ..................... . .. 21.7 MBH Coil airflow:...... .... .__........................... ....._...................._.1002 CFM Sensible heat ratio: ........... ____ .......... ................ 0.843 j Sensible Area per unit load: ................... . ... . .......... 400.7 sqf /Ton Load per unit area: ........... .............. . . . . ... . ............... . ... 30.0 BTU/(hr-sgft) Central Heating Coil Sizing Data Max coil load: .............. . . ................... . ............. 26.1 MBH Coil airflow, ........................_..........._._..._..........__..•........._1002 CFM Load per unit area:_._... .................... . ... . . . . ............... ...30.3 BTU/(hr-sqft) Supply Fan Sizing Data Actual max airflow:..---. ....... .......... .......... . _._ .............. 1002 CFM Standard airflow:._ ................................. ........... ......-........... 986 CFM Actual max airflow per unit area: ._.......... .......... ...... .-.1.17 CFM/sgft Outdoor Ventilation Air Data Design airflow: _.--............ ...................... 309 CFM Airflow per unit floor area: ............. . ............ . .......... .0.36 CFM/sqft Space Sizing Data Calculation method: Transfer Function Method Load occurs at: .... ................. _.......... ........................ Jul 1500 OA DB / WB:.___ ..... .................. --------..............-- ...85.0165.0 Entering DB / WB:-- .................._--.-.--_--- ..... -... .....77.7164.7 Leaving DB / WB:__._.......__ ........ ............. _.............. 57.3/56.1 Coil ADP:._... -..__..__....................._...... - .......--.55.0 Bypass Factor:------_ .............. ......... -- ..................... .......0.100 Resulting RH:-------- -........-..--- _...-...__---------------_.. ............. 60 Design supply temp:----.- ... __.... ... ....... ..... ._... .......... ._---57.6 Load occurs at:..._.._ .. __.......-.--_ ..................._.......Des Htg Ent DB / Lvg DB: ............ .............55.3179.7 F Fan motor BHP:. .......... ... __.......... _ .....44 BHP Fan motor kW:...- -_.....•. ------......---......------ ...............0.33 kW Fanstatic:...._ .............. ----------__-•--- ....... ............ 1.50 in wg Airflow per person: .................. . .. . . . .. . . ......... . . . . . ........... 9.48 CFM/person Space Name Maximum Design Time of Peak Maximum Space Space Cooling _ >Airflow:>- Load Heating! Floor! CFM/zgft j Sensible ,. CFM'` Load KISH 'Area±' MBH s CorridorB 3.4 196 Jul 1500 3.91 260.01 0.75 Training 210B 14.1 8081 Jul 1700 8.51 600.01 1.35 Zone 1 17.5'.10021 Jul 1600 :-12,41 860.0 1.17 Note: Table contains data for all spaces controlled by a single thermostat: Space sizing basis: ........ . .. . . . Peak space load Zone sizing basis: ............ __ ....... Peak zone load Block Load 4.15 Page 1 of 3 System Design Load Summary for RTU -210B Project Name: Iron Workers Union 08/23/2016 Prepared by: Holada -Parks 03:17PM _ DESIGN COOLING DESIGN HEATING Jul 1500 OADB/WB85FI65F tv__ Design Heating Day OADB/WB23F/19.2F Zone Loads based on TFM Detailsf_ Sensible Latent BTU/hr Details{ BTUlhr Sensible Latent BTU/hr BTU/hr Window and Skylight Solar Loads 0 sqft 0 - 0 sgft Wall Transmission 300 sqft 118 - 300 sqft 1763 - Roof Transmission 0 sqft 0 - 0 sqft 0 Window Transmission 0 sqft 0 0 sqft 0 _ Skylight Transmission 0 sqft 0 - 0 sqft 0 Door Loads 0 sqft 0 - 0 sqft 0 Floor Transmission 860 sqft 0 - 860 sqft 0 - Partitions/Ceilings 1240 sqft 861 - 1240 sqft 9000 Overhead Lighting 1290 W 4021 - O W 0 _ Electric Equipment 1030 W 3388 - 0 W 0 People Infiltration 33 7343 0 6520 0 0 0 0 0 0 Miscellaneous Safety Factor 10%/10% 0 1573 0 652 - 15% 0 1614 0 0 >>Total Zone Loads Thermostat and Pulldown Adjustment Plenum Wall Load 0% 173051. -200 0 7172 0 - - 0 12377 -529 0 0 0 Plenum Roof Load 0% 0 - 0 0 Plenum Lighting Load 0% 0 0 0 Ventilation Load Supply Fan Load 309 CFM 1002 CFMI 3487 1114 -3121 - 309 CFM 1002 CFM 15324 -1114 0 >> Total System Loads Central Cooling Coil Central Heating Coil - 21705 21705 0 4051 4052 - 26058 0 26058 <0 0 >> Total Coil Loads - 21705, 4_0.5�2j -� 26058 0 Key. Positive values are clg loads Negative values are htg loads ! Positive values are htg loads Negative values are clg loads Block Load 4.15 Page 2 of 3 Air System Sizing Summary for RTU -125a Project Name: Iron Workers Union 08/23/2016 Prepared by: Holaday-Parks 03.21PMi Air System Information Air System Name:-.... .................. ........... ____RTU -125a Air System Type:. --- __..... ..._....._ ...............Single Zone CAV Sizing Calculation Information Calculation Months:_____... _................ Jan to Dec Central Cooling Coil Sizing Data Maximum Total coil load:..... ........ ......... .................. -.............. -----............. 1.6 Total coil load:...-.. ------- -_------------- - - ... - ........._...._._..18.6 Sensible coil load:,.-, ............. ......... CFM/sqft Coil airflow:----.._.._. Sensible Sensible heat ratio:, .................. _........ .__..-._.,- ------- _.__.-.0.850 Area per unit load:..._.._..-.. _---------------------___...........,......._361.0 MSH Load per unit area:,-, ___ ........... _____33.2 Central Heating Coil Sizing Data Tons MBH MBH CFM sgft/Ton BTU/(hr-sqft) Max coil load:_.__.__ ........................... __--------....----- 28.7 MBH Coil airflow:--- ................ __...... ............ ---..................._....._..799 CFM Load per unit area: ....... ...,-51.3 BTU/(hr-sgft) Supply Fan Sizing Data Actual max airflow :.................................................._ _.._.._...799 CFM Standard airflow: ---...................... _ ..._...787 CFM Actual max airflow per unit area:-........._,. .................... 1.43 CFM/sqft Outdoor Ventilation Air Data Design airflow:------••------...-......_ Airflow per unit floor area:.,._. Space Sizing Data _...... --------------250 CFM - - ......................0.45 CFM/sgft Number of zones: .----------- ...----- ----- - ..................&1 Floor Area:,,.,--, ........... ........ ............ ....... 560.0 sqft Location:..............._.........._.._.__._.:Seattle IAP, Washington Calculation method: ............ ...Transfer Function Method Load occurs at:. ................ .......... _ OA DB / WB:------. ....................... Entering DB / WB: ................. Leaving DB / WB:..__.-_..__ ............. Coil ADP:.. ------- .......... Bypass Factor: .................... ........ Resulting RH:...._._-- .............. Design supply temp:.,,. Load occurs at:_ ................... Ent DB / Lvg DB:.._ .............. _....._.--..Jul 1600 -......._ 84.5/64.8 F .............77.4/65.3 F ...._..-58.8/57.7 F - ............ _..-56.7 F -----0.100 _._......_..... 64 % ......... ....58.9 F ._......,.-_Des Htg _..... .55.1 /88.9 F Fanmotor BHP: ............... _.... .................... ................_-----._.0.35 BHP Fan motor kW:.-.. ......................... __0.26 kW Fanstatic:--.-,,, ......... ............................... .-................. 1.50 in wg Airflow per person:___,.-__ .................___.....----..-----8.93 CFM/person Space Name Maximum Design I Time of Peak Maximums Space Space Cooling Airflow Load Heating, Floor CFM/sqft Sensible : CFMJ Load MSH1 Area MSH s ft. Training 125A 1 12.81 7991 Jul 16001 17,51 560.01 1.43 Block Load 4.15 Page 1 of 3 System Design Load Summary for RTU -125a Project Name: Iron Workers Union 08/23/2016 Prepared by: Holada -Parks 03:21PM Block Load 4.15 Page 2 of 3 DESIGN COOLING DESIGN HEATING _ Jul 1600 OA DBIWB84.5F164.8FOA ~v Design Heating Day DB: WB 23F119.2F Zone Loads based on TFM Details{ Sensible Latent BTU/hr BT�-_ Details Sensible! Latent BTU/hr BTU/hr Window and Skylight Solar Loads 0 sqft 0 - 0 sqft - - Wall Transmission 0 sqft 0 0 sqft 0 Roof Transmission 0 sqft 0 0 sqft 0 - Window Transmission 0 sqft 0 0 sqft 0 - Skylight Transmission 0 sqft 0 0 sqft 0 Door Loads 0 sgft 0 - 0 sqft 0 Floor Transmission 560 sqft 0 560 soft 0 Partitions/Ceilings 1520 sqft -188 1520 sqft 15200 - Overhead Lighting 840 W 2664 - 0 W 0 Electric Equipment 840 W 2779 - 0 W 0 People 28 6405 5600 0 0 0 Infiltration - 0 0 - 0 0 Miscellaneous 0 0 0 0 Safety Factor 10%/10% 1166 560 15% 2280 0 >>Total Zone Loads 12827, 61601 17480 0 Thermostat and Pulldown Ad'ustment - -599 0 - -248 0 Plenum Wall Load 0% 0 0 0 Plenum Roof Load 0% 0 0 0 Plenum Lighting Load 0% 0 - 0 0 Ventilation Load 250 CFM 2707 -3370 250 CFM 12399 0 Supply Fan Load 799 CFM 889 799 CFM -889 - >> Total System Loads 1 15824 2790 28742 0 Central Cooling Coil - 15824 2791 - 0 0 Central Heating Coil J- 0- >> Total Coil Loads Key- ��— - 15824 Positive values are cig loads Negative values are htg loads 2_791 - 28742 Positive values are htg loads Negative values are cig loads 0 Block Load 4.15 Page 2 of 3 16 1 k M 000 El Z j: =D, 3 '7ar --- 7 ° D 170a SMART M+echc#ry cvl Sol utivnsg NW Ironworkers Preliminary TABB Report FIRM: Holaday-Parks, Inc. 4600 S. 134th PI. Tukwila, WA 98168 PHONE: (206) 248-8705 FAX: (866) 745-0799 PROJECT: NW Ironworkers 4550 S. 134th PI. Seattle, WA 98168 DATE: 11/14/2016 CONTACT: Aaron Carter NOTES: Holaday-Parks, Inc. PROJECT #: 59863 RECEIVED CITY OF TUKWILA NOV 16 2016 PERMIT CENTER } 0 D a �0 0 SMART Mechanical Solutio S' Fan Unit PROJECT: NW Ironworkers DATE: 11/14/2016 LOCATION: Tukwila, CONTACT: Dave Petrie PROJECT #: AUTHOR: SYSTEM/UNIT: EF -01 AREA: Data closet Tested By: Dave Petrie Date: 11/14/2016 Motor Data Motor Rated Volts 120 Volts Motor Phase 1 Motor Hertz 60 Hz Sheave Data Drive Type Direct drive Air Test Data Total Fan Design Airflow 650 CFM Total Fan Actual Airflow 640 CFM Holaday-Parks, Inc. Page 1 of 1 Unit Data Unit Location Data closet Unit Serves Data closet Fan Manufacturer Greenheck Fan Model Number SP -710 -VG Test Data; Fan RPM Design 1080 RPM Fan RPM Actual 1080 RPM Motor Volts T1-T2 119 Volts Operating Hertz 60 Hertz Tested By: Dave Petrie Date: 11/14/2016 Motor Data Motor Rated Volts 120 Volts Motor Phase 1 Motor Hertz 60 Hz Sheave Data Drive Type Direct drive Air Test Data Total Fan Design Airflow 650 CFM Total Fan Actual Airflow 640 CFM Holaday-Parks, Inc. Page 1 of 1 HOLMMAYmm, INC SMART Mechanical Solutions® Roof Top Unit PROJECT: NW Ironworkers DATE: 11/14/2016 LOCATION: Tukwila, CONTACT: Dave Petrie PROJECT #: AUTHOR: SYSTEM/UNIT: RTU -01 Unit Data Unit Manufacturer Trane Unit Model Number 4YCC4030A1070A Unit Discharge Downblast RTU -01 Supply Outlet Summary Tested By: Dave Petrie Date: 11/14/2016 Motor Data RTU-01/Supply Fan Motor HP 1/2 HP Motor RPM 1050 RPM Motor Rated Volts 208-230 Volts Motor Phase 1 Motor Hertz 60 Hz Sheave Data RTU-01/Supply Fan Drive Type Direct Drive System/Unit Test Data Total Design Airflow 1000 CFM Total Actual Airflow 990 CFM Outside Air Design 100 CFM Outside Air Actual 110 CFM Return Air Design 900 CFM Return Air Actual 880 CFM RTU-01/Supply Fan Motor Volts T1-T2 119 Volts Operating Hertz 60 Hertz RTU -01 Supply Outlet Summary Tested By: Dave Petrie Date: 11/14/2016 Motor Data RTU-01/Supply Fan Motor HP 1/2 HP Motor RPM 1050 RPM Motor Rated Volts 208-230 Volts Motor Phase 1 Motor Hertz 60 Hz Sheave Data RTU-01/Supply Fan Drive Type Direct Drive System/Unit Area Served Design Reading Prelim Reading Final Reading % Final Deviation Outlet Type Outlet Size Type of Reading Outlet -01 Training 450 355 440 98 CD 12x12 Flowhood Outlet -02 Training 450 425 455 101 CD 12x12 Flowhood Outlet -03 Hallway 100 175 95 95 CD 8x8 Flowhood Totals: 1000 955 990 99 0 - - SYSTEM/UNIT: RTU -02 Unit Data Unit Manufacturer Trane Unit Model Number 4YCC403OA1070A Unit Discharge Downblast RTU -02 Supply Outlet Summary Tested By: Dave Petrie Date: 11/14/2016 Motor Data RTU-02/Supply Fan Motor HP 1/2 HP Motor RPM 1050 RPM Motor Rated Volts 208-230 Volts Motor Phase 1 Motor Hertz 60 Hz Sheave Data RTU-02/Supply Fan Drive Type Direct Drive System/Unit Test Data Total Design Airflow 1000 CFM Total Actual Airflow 1010 CFM Outside Air Design 100 CFM Outside Air Actual 105 CFM Return Air Design 900 CFM Return Air Actual 905 CFM RTU-02/Supply Fan Motor Volts T1-T2 119 Volts Operating Hertz 60 Hertz RTU -02 Supply Outlet Summary Tested By: Dave Petrie Date: 11/14/2016 Motor Data RTU-02/Supply Fan Motor HP 1/2 HP Motor RPM 1050 RPM Motor Rated Volts 208-230 Volts Motor Phase 1 Motor Hertz 60 Hz Sheave Data RTU-02/Supply Fan Drive Type Direct Drive System/Unit Area Served Design Reading Prelim Reading Final Reading % Final Deviation Outlet Type Outlet Size Type of Reading Outlet -01 Training 500 480 505 101 CD 12x12 Flowhood Outlet -02 Training 500 555 505 101 CD 12x12 Flowhood Totals: 1000 1035 1010 101 0 - - Holaday-Parks, Inc. Page 1 of 2 } MY=PA IN(* SMART Mechanical Solutions® Roof Top Unit PROJECT: NW Ironworkers DATE: 11/14/2016 LOCATION: Tukwila, CONTACT: Dave Petrie PROJECT M AUTHOR: SYSTEM/UNIT: RTU -03 Unit Data Unit Manufacturer Trane Unit Model Number 4YCC403OA1070A Unit Discharge Downblast RTU -03 Supply Outlet Summary Tested By: Dave Petrie Date: 11/14/2016 Motor Data RTU-03/Supply Fan Motor HP 1/3 HP Motor RPM 1050 RPM Motor Rated Volts 208-230 Volts Motor Phase 1 Motor Hertz 60 Hz Sheave Data RTU-03/Supply Fan Drive Type Direct Drive SystemlUnit Area Served Test Data Total Design Airflow 800 CFM Total Actual Airflow 855 CFM Outside Air Design 100 CFM Outside Air Actual 110 CFM Return Air Design 700 CFM Return Air Actual 745 CFM RTU-03/Supply Fan Motor Volts T1-T2 119 Volts Operating Hertz 60 Hertz RTU -03 Supply Outlet Summary Tested By: Dave Petrie Date: 11/14/2016 Motor Data RTU-03/Supply Fan Motor HP 1/3 HP Motor RPM 1050 RPM Motor Rated Volts 208-230 Volts Motor Phase 1 Motor Hertz 60 Hz Sheave Data RTU-03/Supply Fan Drive Type Direct Drive SystemlUnit Area Served Design Reading Prelim Reading Final Reading % Final Deviation Outlet Type Outlet Size Type of Reading Outlet -01 Training 400 480 430 108 CD 12x12 Flowhood Outlet -02 Training 400 420 425 106 CD 12x12 Flowhood Totals: 800 900 855 107 0 - - Holaday-Parks, Inc. Page 2 of 2 4/3/2017 City of Tukwila Allan Ekberg, Mayor Department of Community Development Jack Pace, Director CONNIE HARDIN 4600 S.134 PL SEATTLE, WA 98168 RE: Permit No. M16-0136 PNW IRON WORKERS 4550 S 134TH PL Dear Permit Holder: In reviewing our current records, the above noted permit has not received a final inspection by the City of Tukwila Building Division. Per the International Building Code, International Mechanical Code, Uniform Plumbing Code and/or the National Electric Code, every permit issued by the Building Division under the provisions of these codes shall expire by limitation and become null and void if the building or work authorized by such permit has not begun within 180 days from the issuance date of such permit, or if the building or work authorized by such permit is suspended or abandoned at any time after the work has begun for a period of 180 days. Your permit will expire on 5/15/2017. Based on the above, you are hereby advised to: 1) Call the City of Tukwila Inspection Request Line at 206-438-9350 to schedule for the next or final inspection. Each inspection creates a new 180 day period, provided the inspection shows progress. -or- 2) Submit a written request for permit extension to the Permit Center at least seven(7) days before it is due to expire. Address your extension request to the Building Official and state your reason(s) for the need to extend your permit. The Building Code does allow the Building Official to approve one extension of up to 180 days. If it is determined that your extension request is granted, you will be notified by mail. In the event you do not call for an inspection and/or receive an extension prior to 5/15/2017, your permit will become null and void and any further work on the project will require a new permit and associated fees. Thank you for your cooperation in this matter. Sincerely, r Rachelle Ripley Permit Technician File No: M16-0136 6300 Southcenter Boulevard Suite #100 • Tukwila, Washington 98188 • Phone 206-431-3670 • Fax 206-431-3665 PERMIT COORD COPY PLAN REVIEW/ROUTING SLIP PERMIT NUMBER: M16-0136 DATE: 09/07/16 PROJECT NAME: PNW IRON WORKERS SITE ADDRESS: 4550 S 134TH PL X I Original Plan Submittal Revision # before Permit Issued Response to Correction Letter # Revision # after Permit Issued DEPARTMENTS: k3- N C Building Division Public Works ❑ PRELIMINARY REVIEW: Not Applicable ❑ (no approval/review required) REVIEWER'S INITIALS: APPROVALS OR CORRECTIONS: Approved ❑ Corrections Required ❑ (corrections entered in Reviews) Notation: REVIEWER'S INITIALS: AV\ A)V/T q"I)—'t Fire Prevention 0 Structural ❑ Planning Division ❑ Permit Coordinator ❑ DATE: 09/08/16 Structural Review Required ❑ DATE: DUE DATE: 10/06/16 Approved with Conditions R— Denied ❑ (ie: Zoning Issues) DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Plug ❑ PW ❑ Staff Initials: 12/18/2013 HOLADAY PARKS INC Home Espanol Contact Safety & Health Washingtori State Department of Labor & industries HOLADAY PARKS INC Page I of 3 Search L&I w55�s1 A-'7., Index help My L&I Claims & Insurance Workplace Rights Trades & Licensing Owner or tradesperson 4600 S 134TH PL BECK, DAVID CARL SEATTLE, WA 98168 206-248-9700 Principals KING County BECK, DAVID CARL, PRESIDENT CONNELL, DANIEL A, PRESIDENT GIRI, BIJIT, PRESIDENT PIZZEY, GRACE K, VICE PRESIDENT FREEL, JERRY LEE, VICE PRESIDENT PARKS, GERALD T JR, PRESIDENT (End: 08/12/2015) NAILON, JUNE ANNETTE, VICE PRESIDENT (End: 08/12/2015) O'CONNOR, BONNY K, SECRETARY (End: 08/12/2015) BECK, DAVID CLARENCE, TREASURER (End: 08/12/2015) VAN DER VEEN, ERIC M, VICE PRESIDENT (End: 08/14/2013) PIZZEY, GRACE KATHERINE, VICE PRESIDENT (End: 08/14/2013) VAN DER VEEN, JULIE ELIZABETH, MEMBER (End: 08/14/2013) CONNELL, DANIEL AARON, MEMBER (End: 08/14/2013) GIRI, BUTT, MEMBER (End: 08/14/2013) KIEL, RINALD HOWARD, MEMBER (End: 08/14/2013) WHITMYRE, CHRISTIAN, MEMBER (End: 08/14/2013) NELSON, MICHAEL, SECRETARY (End: 11 /04/2010) PARKS, DAVID L, TREASURER (End: 11/04/2010) TALBOT, PAUL, TREASURER (End: 11/04/2010) WA UBI No. Business type 578 004 089 Corporation Help us improve https:Hsecure.Ini.wa.gov/verify/Detail.aspx?UBI=578004089&LIC=HOLADPI379NO&SAW= 9/15/2016 HOLADAY PARKS INC Page 2 of 3 License Verify the contractor's active registration / license / certification (depending on trade) and any past violations. Construction Contractor Active. Meets current requirements. License specialties GENERAL $1,000,000.00 License no. HOLADPI379NO Effective — expiration Effective date 01/21/1983— 09/03/2017 11101/2015 Bond Expiration date LIBERTY MUTUAL INS CO $12,000.00 Bond account no. 23000452 Received by L&I Effective date 08/23/2002 09/01/2002 Expiration date Until Canceled Insurance .............................. Charter Oak Fire Ins Co $1,000,000.00 Policy no. DTC01F465357PHX15 Received by L&I Effective date 10/30/2015 11101/2015 Expiration date 11/01/2016 Insurance history Savings No savings accounts during the previous 6 year period. Lawsuits against the bond or savings No lawsuits against the bond or savings accounts during the previous 6 year period. L&I Tax debts ............ .. No L&I tax debts are recorded for this contractor license during the previous 6 year period, but some debts may be recorded by other agencies. License Violations No l'icerise violations during the previous 6 year period. I Workers' comp Do you know if the business has employees? If so, verify the business is up-to-date on workers' comp premiums. L&I Account ID Account is current. 177,231-00 ................................. Doing business as HOLADAY PARKS INC Estimated workers reported Quarter 2 of Year 2016 "Greater than 100 Workers" L&I account representative T2 / LESLIE QUNELL (360)902-5631 - Email: BAKY235@lni.wa.gov Workplace safety and health Check for any past safety and health violations found on jobsites this business was responsible for. Inspection results date 08/09/2016 No violations Inspection no. 317940177 Location 1011 Western Ave, Suite 1000 Seattle, WA 98104 Help us improve https:Hsecure.Ini.wa.gov/verify/Detail.aspx?UBI=578004089&LIC=HOLADPI379NO&SAW= 9/15/2016 SHEET METAL NOTES 1. DUCT SIZES INDICATED ON PLANS ARE NET INSIDE DIMENSIONS. A CALL -OUT SUCH AS 12" X 12'/SL MEANS A 14' X 14' SHEET METAL DUCT WITH 1' SOUNDLINER, GIVING A NET CLEAR INSIDE DIMENSION OF 12' X 12'. 2. THROUGH PEINIETRATION AND MEMBRANE PENETRATION FIRE STOP AS REQUIRED IN THE IBC SHALL BE PROVIDED AND INSTALLED BY THE MECHANICAL CONTRACTOR. FIRE STOP SYSTEM SHALL BE 3M BRAND FIRE BARRIER CP 25WBT CAULKING OR APPROVED EQUIVALENT. 3. DUCTWORK SHALL BE CONSTRUCTED TO DIMENSIONS INDICATED ON PLANS. THE TOLERANCE OF THESE DIMENSIONS SHAD_ BE AS SPECIFIED IN HOLADAY-PARKS, INC. SHOP STANDARDS MANUAL LENGTHS, AND CRITICAL DIMENSIONS BETWEEN DUCTWORK AND OTHER BUILDING/SYSTEM ELEMENTS ARE INDICATED WHERE A LOCATION OR DIMENSION SCALED FROM THE DRAWING WILL NOT BE ADEQUATE. THE TOLERANCE OF CRITICAL DIMENSIONS, IF NOT INDICATED, SHALT. DEFAULT TO THAT OF THE INSTALLING MECHANIC'S MEASURE DEVICES. SCALED LOCATIONS OR DIMENSIONS ARE NOT SUBJECT TO TOLERANCE GUIDELINES. 4. THESE PLANS HAVE BEEN COORDINATED WITH THE ARCHITECTURAL, STRUCTURAL, SPRINKLER AND ELECTRICAL DRAWINGS. ANY CHANGES IN THIS LAY -OUT MUST BE REVIEWED BY HOLADAY-PARKS' ENGINEERING DEPARTMENT. 5. ALL DUCT INSULATION AND PIPING INSULATION SHALL CONFORM TO 2012 SEC SECTIONS: C403.2.7 AND C403.2.8. 6. DUCT ELBOWS SHAD_ BE RADIUS TYPE WITH FULL WIDTH THROAT RADIUS, UNLESS SHOWN OTHERWISE TURNING VANE ELBOWS SHALL HAVE DOUBLE THICKNESS TURNING VANES INSTALLED IN EVERY RAIL TAB. 7. MATERIALS: a. DUCTBOARD: 1' THICK, U.L LISTED, CLASS 1 FIBERGLASS DUCTBOARD, FABRICATED AND INSTALLED PER SMACNA STANDARDS AND THE MANUFACTURER'S RECOMMENDATIONS. USE ONLY HEAT BONDING TAPE. PRESSURE SENSITIVE TAPE IS NOT ACCEPTABLE. b. SOUNDUNER (INDOORS): 1' THICK, 1-1/2 I.B. DENSITY FIBERGLASS DUCTUNER WITH BLACK MAT FACING. SCHULLER-MANVILLE "PERMACOTE UNACOUSTIC STANDARD", OWENS CORNING 'AEROFLEX PLUS, OR CERTAINTEED TOUGHGARD DUCT LINER WITH ENHANCED SURFACE. (MINIMUM INSTALLED R -VALUE = 3.3) c. SOUNDUNER (OUTDOORS): 2' THICK, 1-1/2 LB. DENSITY FIBERGLASS DUCTUNER WITH BLACK MAT FACING.SCHULLER-MANVILLE T MACOTE UNACOUSTIC STANDARD', OWENS CORNING 'AEROFLEX PLUS ; OR CERTAINTEED TOUGHGARD DUCT LINER WITH ENHANCED SURFACE. (MINIMUM INSTALLED R -VALUE = 7.0) d. RIGID ROUND DUCT. 1' THICK, PRE -FORMED ROUND FIBERGLASS DUCT. JOHNS -MANVILLE 'MICRO-AIRE'. e. INSULATED FLEX DUCT (LOW AND HIGH PRESSURE): UL 181 CLASS 1 AIR DUCT. THERMAREX MK -E. f. UNINSULATED FLEX DUCT (LOW, HIGH PRESSURE, VAPOR PROOF): UL 181 CLASS 1 AIR DUCT. THERMAFLEX S -TL g. DUCIT INSULATION NA INDOORS)::TAUED R1 VA/LUE THICK 3/4 I.B. DENSITY FIBERGLASS WITH F.S.K. VAPOR BARRIER JACh. DUCT INSULATION (OUTDOORS): 3' FIBERGLASS, MINIMUM 3/4 LB. DENSITY, OR 2' FIBERGLASS 1.5 LB. DENSITY WITH VAPOR BARRIER AND WEATHERPROOF JACKET. (MINIMUM INSTALLED R -VALUE = 7.0) SEISMIC RESTRAINING NOTES 1. ANY BASE-MOUNTED/SPRING-MOUNTED EQUIPMENT SHALL HAVE TOTALLY ENCLOSED, SEISMIC RATED SPRINGS (MASON MODEL SSLFH OR EQUAL), OR OPEN SPRINGS PLUS SEISMIC 'SNUBBERS' (MASON MODEL Z-1225 OR EQUAL). 2. ALL SPRING MOUNTED, SUSPENDED EQUIPMENT SHALL HAVE SEISMIC CABLES INSTALLED IN ADDITION TO EQUIPMENT HANGERS. CABLES SHAD_ BE INSTALLED DIAGONALLY UP AND AND AWAY FROM EQUIPMENT CORNERS AND BE ATTACHED TO THE STRUCTURES ABOVE. CABLES SHALL BE LEFT PARTIALLY SLACK. SIZE AND INSTALL CABLES PER SMACNA SEISMIC RESTRAINT MANUAL 3. ANY EQUIPMENT MOUNTED RIGIDLY TO THE BUILDING STRUCTURE SHAD. NOT REQUIRE ADDITIONAL SEISMIC RESTRAINT. 4. RESTRAIN ALL RECTANGULAR DUCTS 6 SQ. FT. OF AREA AND LARGER AND ALL ROUND DUCTS 28' IN DIAMETER AND LARGER. RESTRAINTS SHALL OCCUR 30' O.C. MAXIMUM AND SHALL BE INSTALLED AT EVERY DUCT TURN AND AT THE END OF THE DUCT RUN. SIZE AND INSTALL RESTRAINTS PER SMACNA SEISMIC RESTRAINT MANUAL 5. ALL CEILING MOUNTED DIFFUSERS SHALL HAVE WIRES (16 GA.) ATTACHED TO THE ABOVE FLOOR SLAB OR STRUCTURE. SAFETY WIRES SHAD- BE LEFT PARTIALLY SLACK. ALTERNATE METHOD SHALL BE TO ATTACH DIFFUSERS TO T -BAR GRID WITH SCREWS, RIVETS, OR CEILING CUPS FOR TERMINALS WEIGHING LESS THAN 20 POUNDS. GENERAL NOTES 1. THESE DOCUMENTS ARE BASED ON HOLADAY PARKS ENGIN ERING AND SHOP FABRICATION STANDARDS WHICH ARE NOT SHOWN IN DETAIL ON THESE DRAWINGS. 2. ALL TRADES TO LEAVE 36' CLEARANCE IN FRONT OF MECHANICAL EQUIPMENT ACCESS PANELS FOR SERVICING. 3. CUTTING, FRAMING, PATCHING AND PAINTING OF WALL, CEILING, AND FLOOR OPENINGS SHALL BE BY GENERAL CONTRACTOR. 4. FINAL PAINTING OF GRILLES, REGISTERS AND DIFFUSERS, AS MAY BE REQUIRED BY OPENINGS SHALL BE BY GENERAL CONTRACTOR. 5. GENERAL CONTRACTOR IS RESPONSIBLE FOR TEMPORARY HEAT DURING CONSTRUCTION. 6. UNIT WEIGHTS AND LOCATIONS HAVE BEEN COORDINATED WITH ARCHITECT AND STRUCTURAL ENGINEER TO DETERMINE BUILDING STRUCTURAL ADEQUACY. IF IT IS NECESSARY TO RELOCATE A UNIT, NOTIFY HOLADAY-PARKS' ENGINEERING DEPARTMENT FOR RE -COORDINATION. 7. IN NO INSTANCE SHALL OTHER TRADES HANG OR SUPPORT EQUIPMENT, CEILING WIRES, LIGHT FIXTURE HANGERS, ETC., FROM HVAC EQUIPMENT OR DUCTWORK. B. PLUMBER SHAD_ ROUTE PLUMBING VENTS SO AS TO MAINTAIN MINIMUM 15 FEET OF CLEARANCE FROM OUTSIDE AIR INTAKES. I. WHERE INDICATED ON EXHAUST FAN SCHEDULES, SOME FANS MAY BE FURNISHED WITH A SPEED CONTROL SWITCH AND/OR UNE VOLTAGE THERMOSTAT. ELECTRICAL CONTRACTOR SHALL ROUGH -IN FOR, AND INSTALL SPEED SWITCHES ON FAN HOUSINGS AND T -STATS ON WALL NEXT TO ROOM LIGHT SWITCH UNLESS NOTED OTHERWISE. E.G. SHALL PROVIDE SERVICE AND A DISCONNECT PER CODE, AND DO ALL POWER WIRING, INCLUDING CONNECTING TO EQUIPMENT. MLLES, REGISTERS, DIFFUSERS LEGEND NOTE: THE '/FD' CALLOUT INDICATES A GRILLE WITH U.L. CLASSIFIED AREA SERVED RADIATION DAMPER TO BE INSTALLED IN RATED FLOOR/CEIUNG TYPE OR ROOF/CEIUNG ASSEMBLIES. USE RUSKIN MODEL CFD. INCLUDE WATT THERMAL INSULATION BLANKET FOR LAY -IN T -BAR CEILINGS. NOTE: ALL SUPPLY DIFFUSERS ARE TO BE INSTALLED WITH A DIFFUSER CAN EF -1 W/ PERF DIVIDER, GENSCO REGISTER BOX W/ FLEX COLLAR do DIFF, GREENHECK MODEL COLDC21 OR EQUIV. NOTE: FOR EXPOSED DUCTWORK WITH SUPPLY EXHAUST GRILLES TAKEOFFS 120/1 TO BE GRILLE SIZE PLUS 2' TO MATCH GRILLE FRAME. 1, 2 CLINGI ER (LAY -IN T -BAR CEILING DADDJUSTABLE, 24" XXX' CD 4FIIF CORE WITH FILLER FOR x 24' LAY -IN MODULE -D CFM 11TUS MODEL MCD, BORDER TYPE 3 - KRUEGER SERIES 1244, FRAME 23 I (USE X-0 RUNOUT) CEILING DIFFUSER WITH FIRE DAMPER (LAY -IN T -BAR CEILING) X'xX' CD FD 4 CORE ADJUSTABLE, ALL STEEL CONSTRUCTION, RADIATION - CFM DAMPER SHALL BE RUSKIN MODEL CFD W/ THERMAL INSULATING I BLANKET (USE X"0 RUNOUT) I - X' ACD P CEILING DIFFUSER (PLASTER CEILING) CFM 4 CORE ADJUSTABLE, N' FRAME CFM ESP RPM BHP MHP IN OUT TITUS MODEL MCD, BORDER TYPE 6 - KRUEGER SERIES 1244, FRAME 21 • y X XX CFM P FD CEILING DIFFUSER (PLASTER CEILING) WITH FIRE DAMPER SAME AS C.D./P WITH RADIATION DAMPER AS TRAINING 21 OA NOTED ABOVE 4YCC403OA1070A (USE X"0 RUNOUT) DOWNFLOW CEILING DIFFUSER WITH PERFORATED FACE (LAY -IN T -BAR CEILING). X xX' CD PF 4 CORE ADJUSTABLE, WITH FILLER FOR 24" x 24' LAY -IN MODULE -a- CFM KRUEGER SERIES 1244P, FRAME 23 (USE X' RUNOUT) 1 (USE X' RUNOUT) ®X xX' CLF CEILING LAMINAR FLOW DIFFUSER WITH PERFORATED FACE CFM TITUS TLF-SS JSLOT-INLETO SLOT DIFFUSER FOR LAY -IN CEILING I CFM KEES-100 (SLOT-INt.ET0/FD SLOT DIFFUSER FOR RATED LAY -IN CEILING WITH FIRE DAMPER 1 CFM TEMPMASTER FRD I ISLOT-INLETO/P SLOT DIFFUSER (PLASTER CEILING) CFM KESS K-100, FRAME OPTION 12 I #SLOT-IN.O FD/P SLOT DIFFUSER WITH FIRE DAMPER (PLASTER CEILING) CFM TEMPMASTER MODEL TFD-F OR FRD-F FOR SURFACE MOUNTING 310 SIDEWALL SUPPLY REGISTER S.S.R. DOUBLE DEFLECTION, HORIZONTAL FRONT BLADES, WITH O.B.D. 377 TITUS MODEL 272RL O.B.D. - KRUEGER MODEL 880H O.B.D. � SIDEWALL SUPPLY GRILLE S.S.G. 0 DOUBLE DEFLECTION, HORIZONTAL FRONT BLADES, WITH O.B.D. TITUS MODEL 272RL - KRUEGER MODEL 880H O.B.D. DOWNFLOW LINEAR WALL SUPPLY GRILLE LN.W.S.G. FIXED 15 DEGREE DEFLECTION BLADES (3}1 KRUEGER MODEL 1515, FRAME 415, ALUMINUM CONSTRUCTION 85 RETURN AIR GRILLE R.A.G. ALUMINUM EGGCRATE WITH '/z' x %2' x I2" CORE 24 TITUS MODEL 5OF - KRUEGER EG -5 358 RETURN AIR GRILLE PLASTER CEILING R.A.G./ACCESS INSTALLED IN TUTUS RAPID MOUNT FRAME (MODEL TRM) TO ALLOW WIRING AND DISCONNECTS CEILING ACCESS. FIXED 35 DEGREE REFLECTION BLADES. SINrJ F PnINT KRUEGER MODEL S80 - TITUS MODEL 350RL nnN_ RETURN AIR GRILLE (PLASTER CEILING) ® R.A.G./P. FIXED 35 DEGREE DEFLECTION BLADES KRUEGER MODEL S80H - TUTUS MODEL 35ORL ❑-- S.R.G. SIDEWALL RETURN GRILLE - FIXED 35 DEGREE DEFLECTION BLADES, WITHOUT O.B.D. TITUS MODEL 35ORL - KRUEGER MODEL S80H LINEAR WALL RETURN GRILLE LN.W.R.G. FIXED 0 DEGREE DEFLECTION BLADES KRUEGER MODEL 1500, FRAME 415 ALUMINUM CONSTRUCTION EXHAUST GRILLE E.G. ALUMINUM EGGCRATE WITH '/2" x Y2' x Y2' CORE TITUS MODEL 5OF - KRUEGER EG -5 RETURN AIR GRILLE (PLASTER CEILING) 0 E.G./P. FIXED 35 DEGREE DEFLECTION BLADES TITUS MODEL 35ORL - KRUEGER MODEL S80H EXHAUST REGISTER 0 E.R. FIXED 35 DEGREE DEFLECTION BLADES TITUS MODEL 35ORL O.B.D. - KRUEGER MODEL S80H O.B.D. TRANSFER GRILLE 121 T.G. ALUMINUM EGGCRATE WITH Y2' x Y2' x Y2' CORE TITUS MODEL 5OF - KRUEGER EG -5 TRANSFER GRILLE (PLASTER CEILING OR WALL) 0 T.G./P. FIXED 35 DEGREE DEFLECTION BLADES TITUS MODEL 35ORL - KRUEGER MODEL S8OH EXHAUST 4' STATIONARY LOUVER - LOUVER STEEL CONSTRUCTION RUSKIN MODEL ELF -375 INTAKE 4' STATIONARY LOUVER WITH DRAINABLE BLADES GALVANIZED STEEL CONSTRUCTION LOUVER RUSKIN MODEL ELF -375D FINISH: FACTORY APPLIED PRIME COAT SHEET INDEX DUCT UNDER POSITIVE PRESSURE SHEET SHEET TITLE 1 MO.01 LEGENDS AND NOTES DUCT UNDER NEGATIVE PRESSURE 1 M2.01 LEVEL 1 HVAC PLAN 1 M2.RF ROOF HVAC PLAN TURNING VANES ELEVATION FROM F.F.L. (INSULATION AND DUCT FLANGES EXTEND 1'/2" BELOW BOD CALLOUT) EQUIPMENT IDENTIFICATION THERMOSTAT SENSOR CEILING OR INUNE EXHAUST FAN 24" x 12' RETURN AIR GRILLE W/SOUNDUNED CAN SUPPLY AIR ARROW RETURN AIR ARROW SPEED SWITCH: FURNISHED BY HOLADAY-PARKS, INSTALLED BY ELECTR. CONTR. FUDGBLE CONNECTION SPIN -IN TAKE -OFF do VOLUME DAMPER INDICATES 14' x 14' O.D. SHEETMETAL WITH 1' SOUNDUNER (U.N.O.), 12' x 12" NET I.D. INDICATES UNLINED 12" x 12" S.M. DUCT INDICATES 12' x 12' I.D. DUCTBOARD INDICATES UNLINED 12" x 12' S.M. DUCT WITH INSULATED WRAP RISE OR DROP IN DIRECTION OF FLOW FLEXIBLE DUCT INDICATES FLAT OVAL DUCT SPIN -IN TAKE -OFF do VOLUME DAMPER WITH RIGID ROUND FIBERGLASS DUCT Sa i�P,tIaPERMIT f :CIUIRED F0R: Nlachanical 0- tectrical W-A5 Las Piping . Cib/ of Tukwila Parcel: 2613200005 FOSTORIA GARDEN TRS LOT 2 OF CITY OF TUKWILA SHORT PLAT NO 87 -04 -SS RECORDING NO 8804270766 SD SHORT PLAT DAF - LOT 4 OF CITY OF TUKWILA SHORT PLAT NO 81 -39 -SS RECORDING NO 8204280545 BEING A POR OF LOTS 9,10 & 11 BLK 1 SUBDIVISION OF LOTS 7,8 & 9 OF FOSTORIA TRACTS & BEING A POR OF TRACT 6 OF FOSTORIA GARDEN TRACTS TGW POR OF LOT B OF CITY OF TUKWILA SHORT PLAT NO 80 -13 -SS RECORDING NO 8009030472 BEING A POR OF LOTS 7 & 8 BLK 1 SUBDIVISION OF LOTS 7, 8 & 9 OF FOSTORIA GARDEN TRACTS LY NWLY OF NELY EXT OF SELY LN OF SD LOT 4 OF CITY OF TUKWILA SHORT PLAT NO 81 -39 -SS AS EXTENDED THRU SD LOT B OF CITY OF TUKWILA SHORT PLAT NO W13 -SS ALL BEING KNOWN AS PARCEL A OF CITY OF TUKWILA BDRY LN ADJ NO 84-35 BLA RECORDING NO 8501240853 PORTION TAXABLE I COMMISSIONING - - MECHANICAL SYSTEM SHALL BE COMMISSIONED IN FULL COMPLIANCE WITH THE 2012 WASEC SECTION C408 SYSTEM COMMISSIONING. SCOPE OF WORK Ilk 1. INSTALL THREE (3) ROOFTOP GAS PACKAGED AC UNITS WITH ECONOMIZER, DUCTWORK, GRDS & THERMOSTAT. RELOCATIE ONE_(1) GAS FIRE UNIT HEATER. S, RELOCATE ONE (1) EXISTING DIFFUSER. 4, INSTALL NEW GAS PIPING TO THREE (3) NEW AC UNITS, ONE (1) RELOCATE UNIT HEATER PER PLAN. S. hsrA-CL AmV C0 ec- a-lAm rwmsmR. r.4Aj . 8/31/2016 APPROVED FOR CONSTRUCTION FMcon ISSUE NAMEMATE Permit No.. M I (P` o ao PENDING CITY APPROVAL PERMIT ISSUE Plan review approvaj is sub'ed to errors and omisslons. f �pr®Vn1 Of consirl.Uion documents does not authorize 8/31/2016 t`; 3 vi0laticn Of any adopted code or ordinance. Raxipt REVISIONS OfElpro3s d M QId C py and conditi s is a wl god: No. Date By Description Ely: G 1 8/31/2016 RL PERMIT / CD ISSUE Date: - City of TukvAla BUILDING DIVISION - REVISIONS FNo chanes sh,"ll he made to the scope 1 of work �Arithr,!A prior approval of I Tulc!"ila Cu.Iding Division. 1ti0T4: f;evi=113 i.iil require a natio plan submittal and may include additional plan review fees. I HOLADAYmPARI(S, INC. SMART Mechanical Solutions 0 Mechanical Solutions • Energy Services Building Controis a Service & Maintenance 4600 S. 134TH PLACE SEATTLE, WA 98168 * (206) 249700 HOLADAYPARKS.com WA LICENSE NUMBER: HOLADPI379NO PROJECT DESIGN TEAM Desiqned bv: MC Drawn by: MLK, MV Approved by: Job Number. 43702 Filename: M001.DWG REGISTRATION FAN SCHEDULE FANPERFORMANCE NUMBER AREA SERVED MAKE TYPE DATA MODEL CFM S.P.RPM BHP WATT VOLTS/ PHASE WGT. LBS. REMARKS EF -1 DATA CLOSET GREENHECK CEILING SP -710 -VG 650 0.35 1080 285 120/1 41 1, 2 a_ wnn.n .►�n !11l.AA....f LT w TONS CURB (YIN) .. r191u11W row U1 LV. 2: INSTALL UNE VOLTAGE T -STAT. ROOFTOP CONWANT VOLUME GAS PACKAGED AIR CONDITIONING UNIT SCHEDULE TAG AREA SERVED MAKE MODEL NOM. CONFIGURATION FACTORY ECONOMIZER LOW AMBIENT CONTROL ENTERING AIR CONDENSING ARI EFFICIENCY COOLING CAPCITY OUTSIDE SUPPLY FAN DATA GAS HEAT MBH WINTER ELECTRICAL WEIGHT FILTERS TONS CURB (YIN) OPT. (Y/N) TYPE TEMP 'F AIR CFM DESIGN 'F (LBS) REMARKS Y/N DB/H FACT./FU) DB WB EER SEER TOTAL SENSIBLE CFM ESP RPM BHP MHP IN OUT VOLTS/PH MCA MFS QTYI SIZE RTU -1 TRAINING 21 OA TRANE 4YCC403OA1070A 2.5 DOWNFLOW Y Y DB FIELD N (3) 80 67 85 12.0 14.0 28.2 - 330 1000 0.6 1050 - 0.5 70 56.7 24 208/230/1 22.6 35 377 - - 1, 2, 3.4 RTU -2 TRAINING 210B TRANE 4YCC4030AI070A 2.5 DOWNFLOW Y Y DB FIELD N (3) 1 80 67 85 12.0 14.0 28.2 - 310 1000 0.6 1050 - 0.5 70 56.7 24 208/230/1 22.6 35 377 - - 11 2, 3, 4 RTU -3 TRAINING 125A TRANE 14YCC4030A1070AI 2.0 DOWNFLOW Y Y DB FIELD N (3}1 80 67 85 12.0 14.0 1 24.6 - 200 800 1 0.6 1050 - 0.33 60 48.1 24 208/230/1 19.1 30 358 - - 1, 2, 3, 4 1: WIRING AND DISCONNECTS RY EC_ SINrJ F PnINT POWFR CnNNFr nnN_ 2: ECONOMIZER AND RELIEF DAMPER PROVIDED BY FACTORY AND INSTALLED BY M.C. 3: PROVIDE 7 -DAYS PROGRAMMABLE THERMOSTAT. 4: FRESH AIR INTAKE, AND REUEF/EXHAUST SHALL BE EQUIPPED WITH LOW LEAK (4 CFM/SQ.FT.), CLASS 1A MOTORIZED DAMPER THAT AUTOMATICALLY CLOSE DURING UNOCCUPIED HOURS. REVIEWED FOR CODE COMPLIANCE APPROVED .af - t SEP 1 2016 Cita' of Tukwila CI T''r 0 IF i UK�'VILr - SIa� 0 1 2015 SHEET TITLE PERMIT CENTER ALL Mms fff.SFRYE4 THESE ORAWiMGg saow IN ANY FIXW TO ma"Y7ARM. (D--- - o Orr i CE I'll 11L-6] Ti�!NINS 11'.�41 ICE 7---1 12x1 2 1' Z 12x1 2: CD tt 5 -b7T—YP.2)- 4-Tyl �2)- 0 -A" J.1 --Now f 1 . --40 x q W --A x18- TG T - ------ ---- E L - - ------ --- ---- - - jj- 8'0 r ON Imms\\- L V, W CD z 0 10 % ---100 -J y2" - T T EXISTING GAS --------- UNIT HEATER ri '/77[p ,Y2 " W01 - Wit 44 C4:9CE 0i . -1 W-1 j 120 2 ZD T 4 - t 0 YF2) "j, - --- -- it L I 1 Y t VE f LL %OE ho TEE T T LEVEL 1 HVAC PLAN SCNm Vw - T -T ,Y2 UNIT HEATER EXISTING GAS UNIT HEATER FOR-,* �TCRAGH I FT5- j 0 REVIEWED FOR CODE COMPLIANCE APPROVED D PPROVED SEP 13 2016 City of Tu ala BUILDING DIVISION RECEIVED CITY OF TUKWILA SEP 0 1 2016 PERMIT CENTER UNETYPE-LEGEND EXISTING CONSTRUCTION NEW CONSTRUCTION -------- DEMOUTION I ALL M01M RESERVED. M*n OMW,*M SIMOW Of MY FORK M "M"Y-P&W. HOLADAYmPA91% INC. SMART Mechanical Solutions e Mechanical Solutions e Energy Services Building Controls * Service & Maintenance 4600 S. 134TH PLACE SEATTLE, WA 98168 * (206) 248-9700 HOLADAYPARKS.com WA LICENSE NUMBER: HOLADPI379N0 "mmmmmmll PROJECT I < U) C) Lo Z: cn Lo ,,I - DESIGN TEAM Designed bv: MC Drawn by: MLK, MV Approved by: Job Number 43702 Filename: M201.DWG REGISTRATION 8/31/20`16 APPROVED FOR CONSTRUCTION I ISSUE NANIMATE I PENDING CITY APPROVAL PERMIT ISSUE 8/31/2016 R-VISIONS_tf""""""""""""" No. Date By Description 1 8/31/2016 RL PERMIT / CD ISSUE SHEET TITLE LEVEL 1 HVAC PLAN --I SHEET NUMBER F' M2.01 W REPRODUCED IN ANY FOM OR BY ANY MEANS VMH= PE"SSM INWFdWO FROM HMADAY MOM W- o_ - TOP OF CURB MUST BE LEVEL & FLAT (SEE NOTES 1 & 2) 2x6 WOOD BACKING BY G.C. 16 GAUGE ROOF CURB (BY A/C MFG.) ml 0 4- WIDIT � 16GA SEISMIC RESTRAINTS QUANTITY AND CONNECTION PER TABLE BELOW No. 10)�i,-' SCREW SEAL &' AikE WATERTIGHT STOP ROOFING FELT._ BEFORE CURB LIP SHEETMETAL FLASHING INSTALLED OVER ROOFIN( FELT. (BY MECH.) BUILT—UP ROOFING (SEE NOTE 5) APPROXIMATE ED OF / BY G.C. i ROOF OPENING CANT STRIP (SEE NOTE 3) X,\ (SEE NOTE 5) ROOF DECK NOTES: 1. GENERAL CONTRACTOR SHALL PROVIDE SHIMS AS REQUIRED TO MAKE CURB LEVEL MAXIMUM ALLOWABLE SLOPE IS %4- PER 10'. 2. TOP OF CURB MUST BE TRUE (FLAT) TO PROVIDE AN ACCEPTABLE SEALING SURFACE. 3. ROOF STRUCTURE, ROOF DECK, INSULATION, CANT STRIP & BUILT—UP ROOFING BY GENERAL CONTRACTOR. 4. STRUCTURAL MEMBERS MUST NOT INTERFERE kATH ROOF OPENINGS. 5. FASTEN ROOF CURB SECURELY TO STRUCTURAL MEMBERS. kJJ78 w Ana ovua FASTENER SCHEDULE Lo EQUIP. SVM. UNI DIMENSIONS L I W H WEIGHT LBS. OF 16GA STRAPS OF FAST. INSIDE OF CURB DIMENSIONS PER STRAP(D L I W H WEIGHT RTU -1 49' 43' 35.5" 377 6 6 43.5' 36' 14- — RTU -2 49' 43' 35.5" 377 6 6 43.5" 1 36' 14" — RTU -3 49' 43' 35.5" 358 6 6 43.5' 36` 14" — (D SEE STRAP DETAIL FOR FASTENER TYPE AND SIZE DETAIL - CURB WITH SEISMIC RESTRAINT SCAE- NM 0 STRUCTURAL CALCULATION PROVIDED BY OTHERS IF REQUIRED BY CODE OFFICIAL , REVIEWED FOR 466E COMPLIANCE ' APPROVED ' SEP 13 2016 City ofrukvwita BUILDING DIVISION RECEIVEC) CIT`: OF TUKWILA SES 0 9 2416 PERMIT CENTER EXISTING CONSTRUCTION NEW CONSTRUCTION DBAOUTION AU III" S RESERVED. THESE MA`MNCi4 BELONG 114 ANY FOM TO HOtADAY-PAFM. NO.. NO PAW OF THS HOLADAY m SMART Mechanical Solutions Mechanical Solutions . Energy Services Building Controls s Service & Maintenance 4600 S. 134TH PLACE SEATTLE, WA 98168 . (206) 248-9700 HOLADAYPARKS.com WA LICENSE NUMBER: HOLADPI379NO PROJECT DESIGN TEAM Desiuned bv: MC Drawn by: MILK, MV Approved by: Job Number. 43702 Filename: M2RF.DWG REGISTRATION 8/31/2016 APPROVED FOR CONSTRUCTION ISSUE NAMFJDATE PENDING CITY APPROVAL PERMIT ISSUE 8131/2016 11 REVISIONS No. Date By Description 1 8/31/2016 RL PERMIT / CD ISSUE SHEET TITLE ROOF HVAC PLAN SHEET NUMBER FPIOM HOLIDAY PAW. BIG Lo Lo DESIGN TEAM Desiuned bv: MC Drawn by: MILK, MV Approved by: Job Number. 43702 Filename: M2RF.DWG REGISTRATION 8/31/2016 APPROVED FOR CONSTRUCTION ISSUE NAMFJDATE PENDING CITY APPROVAL PERMIT ISSUE 8131/2016 11 REVISIONS No. Date By Description 1 8/31/2016 RL PERMIT / CD ISSUE SHEET TITLE ROOF HVAC PLAN SHEET NUMBER FPIOM HOLIDAY PAW. BIG SHEET METAL NOTES 1. DUCT SIZES INDICATED ON PLANS ARE NET INSIDE DIMENSIONS. A CALL -OUT SUCH AS 12" X 12'/SL MEANS A 14' X 14' SHEET METAL DUCT WITH 1' SOUNDLINER, GIVING A NET CLEAR INSIDE DIMENSION OF 12' X 12'. 2. THROUGH PEINIETRATION AND MEMBRANE PENETRATION FIRE STOP AS REQUIRED IN THE IBC SHALL BE PROVIDED AND INSTALLED BY THE MECHANICAL CONTRACTOR. FIRE STOP SYSTEM SHALL BE 3M BRAND FIRE BARRIER CP 25WBT CAULKING OR APPROVED EQUIVALENT. 3. DUCTWORK SHALL BE CONSTRUCTED TO DIMENSIONS INDICATED ON PLANS. THE TOLERANCE OF THESE DIMENSIONS SHAD_ BE AS SPECIFIED IN HOLADAY-PARKS, INC. SHOP STANDARDS MANUAL LENGTHS, AND CRITICAL DIMENSIONS BETWEEN DUCTWORK AND OTHER BUILDING/SYSTEM ELEMENTS ARE INDICATED WHERE A LOCATION OR DIMENSION SCALED FROM THE DRAWING WILL NOT BE ADEQUATE. THE TOLERANCE OF CRITICAL DIMENSIONS, IF NOT INDICATED, SHALT. DEFAULT TO THAT OF THE INSTALLING MECHANIC'S MEASURE DEVICES. SCALED LOCATIONS OR DIMENSIONS ARE NOT SUBJECT TO TOLERANCE GUIDELINES. 4. THESE PLANS HAVE BEEN COORDINATED WITH THE ARCHITECTURAL, STRUCTURAL, SPRINKLER AND ELECTRICAL DRAWINGS. ANY CHANGES IN THIS LAY -OUT MUST BE REVIEWED BY HOLADAY-PARKS' ENGINEERING DEPARTMENT. 5. ALL DUCT INSULATION AND PIPING INSULATION SHALL CONFORM TO 2012 SEC SECTIONS: C403.2.7 AND C403.2.8. 6. DUCT ELBOWS SHAD_ BE RADIUS TYPE WITH FULL WIDTH THROAT RADIUS, UNLESS SHOWN OTHERWISE TURNING VANE ELBOWS SHALL HAVE DOUBLE THICKNESS TURNING VANES INSTALLED IN EVERY RAIL TAB. 7. MATERIALS: a. DUCTBOARD: 1' THICK, U.L LISTED, CLASS 1 FIBERGLASS DUCTBOARD, FABRICATED AND INSTALLED PER SMACNA STANDARDS AND THE MANUFACTURER'S RECOMMENDATIONS. USE ONLY HEAT BONDING TAPE. PRESSURE SENSITIVE TAPE IS NOT ACCEPTABLE. b. SOUNDUNER (INDOORS): 1' THICK, 1-1/2 I.B. DENSITY FIBERGLASS DUCTUNER WITH BLACK MAT FACING. SCHULLER-MANVILLE "PERMACOTE UNACOUSTIC STANDARD", OWENS CORNING 'AEROFLEX PLUS, OR CERTAINTEED TOUGHGARD DUCT LINER WITH ENHANCED SURFACE. (MINIMUM INSTALLED R -VALUE = 3.3) c. SOUNDUNER (OUTDOORS): 2' THICK, 1-1/2 LB. DENSITY FIBERGLASS DUCTUNER WITH BLACK MAT FACING.SCHULLER-MANVILLE T MACOTE UNACOUSTIC STANDARD', OWENS CORNING 'AEROFLEX PLUS ; OR CERTAINTEED TOUGHGARD DUCT LINER WITH ENHANCED SURFACE. (MINIMUM INSTALLED R -VALUE = 7.0) d. RIGID ROUND DUCT. 1' THICK, PRE -FORMED ROUND FIBERGLASS DUCT. JOHNS -MANVILLE 'MICRO-AIRE'. e. INSULATED FLEX DUCT (LOW AND HIGH PRESSURE): UL 181 CLASS 1 AIR DUCT. THERMAREX MK -E. f. UNINSULATED FLEX DUCT (LOW, HIGH PRESSURE, VAPOR PROOF): UL 181 CLASS 1 AIR DUCT. THERMAFLEX S -TL g. DUCIT INSULATION NA INDOORS)::TAUED R1 VA/LUE THICK 3/4 I.B. DENSITY FIBERGLASS WITH F.S.K. VAPOR BARRIER JACh. DUCT INSULATION (OUTDOORS): 3' FIBERGLASS, MINIMUM 3/4 LB. DENSITY, OR 2' FIBERGLASS 1.5 LB. DENSITY WITH VAPOR BARRIER AND WEATHERPROOF JACKET. (MINIMUM INSTALLED R -VALUE = 7.0) SEISMIC RESTRAINING NOTES 1. ANY BASE-MOUNTED/SPRING-MOUNTED EQUIPMENT SHALL HAVE TOTALLY ENCLOSED, SEISMIC RATED SPRINGS (MASON MODEL SSLFH OR EQUAL), OR OPEN SPRINGS PLUS SEISMIC 'SNUBBERS' (MASON MODEL Z-1225 OR EQUAL). 2. ALL SPRING MOUNTED, SUSPENDED EQUIPMENT SHALL HAVE SEISMIC CABLES INSTALLED IN ADDITION TO EQUIPMENT HANGERS. CABLES SHAD_ BE INSTALLED DIAGONALLY UP AND AND AWAY FROM EQUIPMENT CORNERS AND BE ATTACHED TO THE STRUCTURES ABOVE. CABLES SHALL BE LEFT PARTIALLY SLACK. SIZE AND INSTALL CABLES PER SMACNA SEISMIC RESTRAINT MANUAL 3. ANY EQUIPMENT MOUNTED RIGIDLY TO THE BUILDING STRUCTURE SHAD. NOT REQUIRE ADDITIONAL SEISMIC RESTRAINT. 4. RESTRAIN ALL RECTANGULAR DUCTS 6 SQ. FT. OF AREA AND LARGER AND ALL ROUND DUCTS 28' IN DIAMETER AND LARGER. RESTRAINTS SHALL OCCUR 30' O.C. MAXIMUM AND SHALL BE INSTALLED AT EVERY DUCT TURN AND AT THE END OF THE DUCT RUN. SIZE AND INSTALL RESTRAINTS PER SMACNA SEISMIC RESTRAINT MANUAL 5. ALL CEILING MOUNTED DIFFUSERS SHALL HAVE WIRES (16 GA.) ATTACHED TO THE ABOVE FLOOR SLAB OR STRUCTURE. SAFETY WIRES SHAD- BE LEFT PARTIALLY SLACK. ALTERNATE METHOD SHALL BE TO ATTACH DIFFUSERS TO T -BAR GRID WITH SCREWS, RIVETS, OR CEILING CUPS FOR TERMINALS WEIGHING LESS THAN 20 POUNDS. GENERAL NOTES 1. THESE DOCUMENTS ARE BASED ON HOLADAY PARKS ENGIN ERING AND SHOP FABRICATION STANDARDS WHICH ARE NOT SHOWN IN DETAIL ON THESE DRAWINGS. 2. ALL TRADES TO LEAVE 36' CLEARANCE IN FRONT OF MECHANICAL EQUIPMENT ACCESS PANELS FOR SERVICING. 3. CUTTING, FRAMING, PATCHING AND PAINTING OF WALL, CEILING, AND FLOOR OPENINGS SHALL BE BY GENERAL CONTRACTOR. 4. FINAL PAINTING OF GRILLES, REGISTERS AND DIFFUSERS, AS MAY BE REQUIRED BY OPENINGS SHALL BE BY GENERAL CONTRACTOR. 5. GENERAL CONTRACTOR IS RESPONSIBLE FOR TEMPORARY HEAT DURING CONSTRUCTION. 6. UNIT WEIGHTS AND LOCATIONS HAVE BEEN COORDINATED WITH ARCHITECT AND STRUCTURAL ENGINEER TO DETERMINE BUILDING STRUCTURAL ADEQUACY. IF IT IS NECESSARY TO RELOCATE A UNIT, NOTIFY HOLADAY-PARKS' ENGINEERING DEPARTMENT FOR RE -COORDINATION. 7. IN NO INSTANCE SHALL OTHER TRADES HANG OR SUPPORT EQUIPMENT, CEILING WIRES, LIGHT FIXTURE HANGERS, ETC., FROM HVAC EQUIPMENT OR DUCTWORK. B. PLUMBER SHAD_ ROUTE PLUMBING VENTS SO AS TO MAINTAIN MINIMUM 15 FEET OF CLEARANCE FROM OUTSIDE AIR INTAKES. I. WHERE INDICATED ON EXHAUST FAN SCHEDULES, SOME FANS MAY BE FURNISHED WITH A SPEED CONTROL SWITCH AND/OR UNE VOLTAGE THERMOSTAT. ELECTRICAL CONTRACTOR SHALL ROUGH -IN FOR, AND INSTALL SPEED SWITCHES ON FAN HOUSINGS AND T -STATS ON WALL NEXT TO ROOM LIGHT SWITCH UNLESS NOTED OTHERWISE. E.G. SHALL PROVIDE SERVICE AND A DISCONNECT PER CODE, AND DO ALL POWER WIRING, INCLUDING CONNECTING TO EQUIPMENT. MLLES, REGISTERS, DIFFUSERS LEGEND NOTE: THE '/FD' CALLOUT INDICATES A GRILLE WITH U.L. CLASSIFIED AREA SERVED RADIATION DAMPER TO BE INSTALLED IN RATED FLOOR/CEIUNG TYPE OR ROOF/CEIUNG ASSEMBLIES. USE RUSKIN MODEL CFD. INCLUDE WATT THERMAL INSULATION BLANKET FOR LAY -IN T -BAR CEILINGS. NOTE: ALL SUPPLY DIFFUSERS ARE TO BE INSTALLED WITH A DIFFUSER CAN EF -1 W/ PERF DIVIDER, GENSCO REGISTER BOX W/ FLEX COLLAR do DIFF, GREENHECK MODEL COLDC21 OR EQUIV. NOTE: FOR EXPOSED DUCTWORK WITH SUPPLY EXHAUST GRILLES TAKEOFFS 120/1 TO BE GRILLE SIZE PLUS 2' TO MATCH GRILLE FRAME. 1, 2 CLINGI ER (LAY -IN T -BAR CEILING DADDJUSTABLE, 24" XXX' CD 4FIIF CORE WITH FILLER FOR x 24' LAY -IN MODULE -D CFM 11TUS MODEL MCD, BORDER TYPE 3 - KRUEGER SERIES 1244, FRAME 23 I (USE X-0 RUNOUT) CEILING DIFFUSER WITH FIRE DAMPER (LAY -IN T -BAR CEILING) X'xX' CD FD 4 CORE ADJUSTABLE, ALL STEEL CONSTRUCTION, RADIATION - CFM DAMPER SHALL BE RUSKIN MODEL CFD W/ THERMAL INSULATING I BLANKET (USE X"0 RUNOUT) I - X' ACD P CEILING DIFFUSER (PLASTER CEILING) CFM 4 CORE ADJUSTABLE, N' FRAME CFM ESP RPM BHP MHP IN OUT TITUS MODEL MCD, BORDER TYPE 6 - KRUEGER SERIES 1244, FRAME 21 • y X XX CFM P FD CEILING DIFFUSER (PLASTER CEILING) WITH FIRE DAMPER SAME AS C.D./P WITH RADIATION DAMPER AS TRAINING 21 OA NOTED ABOVE 4YCC403OA1070A (USE X"0 RUNOUT) DOWNFLOW CEILING DIFFUSER WITH PERFORATED FACE (LAY -IN T -BAR CEILING). X xX' CD PF 4 CORE ADJUSTABLE, WITH FILLER FOR 24" x 24' LAY -IN MODULE -a- CFM KRUEGER SERIES 1244P, FRAME 23 (USE X' RUNOUT) 1 (USE X' RUNOUT) ®X xX' CLF CEILING LAMINAR FLOW DIFFUSER WITH PERFORATED FACE CFM TITUS TLF-SS JSLOT-INLETO SLOT DIFFUSER FOR LAY -IN CEILING I CFM KEES-100 (SLOT-INt.ET0/FD SLOT DIFFUSER FOR RATED LAY -IN CEILING WITH FIRE DAMPER 1 CFM TEMPMASTER FRD I ISLOT-INLETO/P SLOT DIFFUSER (PLASTER CEILING) CFM KESS K-100, FRAME OPTION 12 I #SLOT-IN.O FD/P SLOT DIFFUSER WITH FIRE DAMPER (PLASTER CEILING) CFM TEMPMASTER MODEL TFD-F OR FRD-F FOR SURFACE MOUNTING 310 SIDEWALL SUPPLY REGISTER S.S.R. DOUBLE DEFLECTION, HORIZONTAL FRONT BLADES, WITH O.B.D. 377 TITUS MODEL 272RL O.B.D. - KRUEGER MODEL 880H O.B.D. � SIDEWALL SUPPLY GRILLE S.S.G. 0 DOUBLE DEFLECTION, HORIZONTAL FRONT BLADES, WITH O.B.D. TITUS MODEL 272RL - KRUEGER MODEL 880H O.B.D. DOWNFLOW LINEAR WALL SUPPLY GRILLE LN.W.S.G. FIXED 15 DEGREE DEFLECTION BLADES (3}1 KRUEGER MODEL 1515, FRAME 415, ALUMINUM CONSTRUCTION 85 RETURN AIR GRILLE R.A.G. ALUMINUM EGGCRATE WITH '/z' x %2' x I2" CORE 24 TITUS MODEL 5OF - KRUEGER EG -5 358 RETURN AIR GRILLE PLASTER CEILING R.A.G./ACCESS INSTALLED IN TUTUS RAPID MOUNT FRAME (MODEL TRM) TO ALLOW WIRING AND DISCONNECTS CEILING ACCESS. FIXED 35 DEGREE REFLECTION BLADES. SINrJ F PnINT KRUEGER MODEL S80 - TITUS MODEL 350RL nnN_ RETURN AIR GRILLE (PLASTER CEILING) ® R.A.G./P. FIXED 35 DEGREE DEFLECTION BLADES KRUEGER MODEL S80H - TUTUS MODEL 35ORL ❑-- S.R.G. SIDEWALL RETURN GRILLE - FIXED 35 DEGREE DEFLECTION BLADES, WITHOUT O.B.D. TITUS MODEL 35ORL - KRUEGER MODEL S80H LINEAR WALL RETURN GRILLE LN.W.R.G. FIXED 0 DEGREE DEFLECTION BLADES KRUEGER MODEL 1500, FRAME 415 ALUMINUM CONSTRUCTION EXHAUST GRILLE E.G. ALUMINUM EGGCRATE WITH '/2" x Y2' x Y2' CORE TITUS MODEL 5OF - KRUEGER EG -5 RETURN AIR GRILLE (PLASTER CEILING) 0 E.G./P. FIXED 35 DEGREE DEFLECTION BLADES TITUS MODEL 35ORL - KRUEGER MODEL S80H EXHAUST REGISTER 0 E.R. FIXED 35 DEGREE DEFLECTION BLADES TITUS MODEL 35ORL O.B.D. - KRUEGER MODEL S80H O.B.D. TRANSFER GRILLE 121 T.G. ALUMINUM EGGCRATE WITH Y2' x Y2' x Y2' CORE TITUS MODEL 5OF - KRUEGER EG -5 TRANSFER GRILLE (PLASTER CEILING OR WALL) 0 T.G./P. FIXED 35 DEGREE DEFLECTION BLADES TITUS MODEL 35ORL - KRUEGER MODEL S8OH EXHAUST 4' STATIONARY LOUVER - LOUVER STEEL CONSTRUCTION RUSKIN MODEL ELF -375 INTAKE 4' STATIONARY LOUVER WITH DRAINABLE BLADES GALVANIZED STEEL CONSTRUCTION LOUVER RUSKIN MODEL ELF -375D FINISH: FACTORY APPLIED PRIME COAT SHEET INDEX DUCT UNDER POSITIVE PRESSURE SHEET SHEET TITLE 1 MO.01 LEGENDS AND NOTES DUCT UNDER NEGATIVE PRESSURE 1 M2.01 LEVEL 1 HVAC PLAN 1 M2.RF ROOF HVAC PLAN TURNING VANES ELEVATION FROM F.F.L. (INSULATION AND DUCT FLANGES EXTEND 1'/2" BELOW BOD CALLOUT) EQUIPMENT IDENTIFICATION THERMOSTAT SENSOR CEILING OR INUNE EXHAUST FAN 24" x 12' RETURN AIR GRILLE W/SOUNDUNED CAN SUPPLY AIR ARROW RETURN AIR ARROW SPEED SWITCH: FURNISHED BY HOLADAY-PARKS, INSTALLED BY ELECTR. CONTR. FUDGBLE CONNECTION SPIN -IN TAKE -OFF do VOLUME DAMPER INDICATES 14' x 14' O.D. SHEETMETAL WITH 1' SOUNDUNER (U.N.O.), 12' x 12" NET I.D. INDICATES UNLINED 12" x 12" S.M. DUCT INDICATES 12' x 12' I.D. DUCTBOARD INDICATES UNLINED 12" x 12' S.M. DUCT WITH INSULATED WRAP RISE OR DROP IN DIRECTION OF FLOW FLEXIBLE DUCT INDICATES FLAT OVAL DUCT SPIN -IN TAKE -OFF do VOLUME DAMPER WITH RIGID ROUND FIBERGLASS DUCT Sa i�P,tIaPERMIT f :CIUIRED F0R: Nlachanical 0- tectrical W-A5 Las Piping . Cib/ of Tukwila Parcel: 2613200005 FOSTORIA GARDEN TRS LOT 2 OF CITY OF TUKWILA SHORT PLAT NO 87 -04 -SS RECORDING NO 8804270766 SD SHORT PLAT DAF - LOT 4 OF CITY OF TUKWILA SHORT PLAT NO 81 -39 -SS RECORDING NO 8204280545 BEING A POR OF LOTS 9,10 & 11 BLK 1 SUBDIVISION OF LOTS 7,8 & 9 OF FOSTORIA TRACTS & BEING A POR OF TRACT 6 OF FOSTORIA GARDEN TRACTS TGW POR OF LOT B OF CITY OF TUKWILA SHORT PLAT NO 80 -13 -SS RECORDING NO 8009030472 BEING A POR OF LOTS 7 & 8 BLK 1 SUBDIVISION OF LOTS 7, 8 & 9 OF FOSTORIA GARDEN TRACTS LY NWLY OF NELY EXT OF SELY LN OF SD LOT 4 OF CITY OF TUKWILA SHORT PLAT NO 81 -39 -SS AS EXTENDED THRU SD LOT B OF CITY OF TUKWILA SHORT PLAT NO W13 -SS ALL BEING KNOWN AS PARCEL A OF CITY OF TUKWILA BDRY LN ADJ NO 84-35 BLA RECORDING NO 8501240853 PORTION TAXABLE I COMMISSIONING - - MECHANICAL SYSTEM SHALL BE COMMISSIONED IN FULL COMPLIANCE WITH THE 2012 WASEC SECTION C408 SYSTEM COMMISSIONING. SCOPE OF WORK Ilk 1. INSTALL THREE (3) ROOFTOP GAS PACKAGED AC UNITS WITH ECONOMIZER, DUCTWORK, GRDS & THERMOSTAT. RELOCATIE ONE_(1) GAS FIRE UNIT HEATER. S, RELOCATE ONE (1) EXISTING DIFFUSER. 4, INSTALL NEW GAS PIPING TO THREE (3) NEW AC UNITS, ONE (1) RELOCATE UNIT HEATER PER PLAN. S. hsrA-CL AmV C0 ec- a-lAm rwmsmR. r.4Aj . 8/31/2016 APPROVED FOR CONSTRUCTION FMcon ISSUE NAMEMATE Permit No.. M I (P` o ao PENDING CITY APPROVAL PERMIT ISSUE Plan review approvaj is sub'ed to errors and omisslons. f �pr®Vn1 Of consirl.Uion documents does not authorize 8/31/2016 t`; 3 vi0laticn Of any adopted code or ordinance. Raxipt REVISIONS OfElpro3s d M QId C py and conditi s is a wl god: No. Date By Description Ely: G 1 8/31/2016 RL PERMIT / CD ISSUE Date: - City of TukvAla BUILDING DIVISION - REVISIONS FNo chanes sh,"ll he made to the scope 1 of work �Arithr,!A prior approval of I Tulc!"ila Cu.Iding Division. 1ti0T4: f;evi=113 i.iil require a natio plan submittal and may include additional plan review fees. I HOLADAYmPARI(S, INC. SMART Mechanical Solutions 0 Mechanical Solutions • Energy Services Building Controis a Service & Maintenance 4600 S. 134TH PLACE SEATTLE, WA 98168 * (206) 249700 HOLADAYPARKS.com WA LICENSE NUMBER: HOLADPI379NO PROJECT DESIGN TEAM Desiqned bv: MC Drawn by: MLK, MV Approved by: Job Number. 43702 Filename: M001.DWG REGISTRATION FAN SCHEDULE FANPERFORMANCE NUMBER AREA SERVED MAKE TYPE DATA MODEL CFM S.P.RPM BHP WATT VOLTS/ PHASE WGT. LBS. REMARKS EF -1 DATA CLOSET GREENHECK CEILING SP -710 -VG 650 0.35 1080 285 120/1 41 1, 2 a_ wnn.n .►�n !11l.AA....f LT w TONS CURB (YIN) .. r191u11W row U1 LV. 2: INSTALL UNE VOLTAGE T -STAT. ROOFTOP CONWANT VOLUME GAS PACKAGED AIR CONDITIONING UNIT SCHEDULE TAG AREA SERVED MAKE MODEL NOM. CONFIGURATION FACTORY ECONOMIZER LOW AMBIENT CONTROL ENTERING AIR CONDENSING ARI EFFICIENCY COOLING CAPCITY OUTSIDE SUPPLY FAN DATA GAS HEAT MBH WINTER ELECTRICAL WEIGHT FILTERS TONS CURB (YIN) OPT. (Y/N) TYPE TEMP 'F AIR CFM DESIGN 'F (LBS) REMARKS Y/N DB/H FACT./FU) DB WB EER SEER TOTAL SENSIBLE CFM ESP RPM BHP MHP IN OUT VOLTS/PH MCA MFS QTYI SIZE RTU -1 TRAINING 21 OA TRANE 4YCC403OA1070A 2.5 DOWNFLOW Y Y DB FIELD N (3) 80 67 85 12.0 14.0 28.2 - 330 1000 0.6 1050 - 0.5 70 56.7 24 208/230/1 22.6 35 377 - - 1, 2, 3.4 RTU -2 TRAINING 210B TRANE 4YCC4030AI070A 2.5 DOWNFLOW Y Y DB FIELD N (3) 1 80 67 85 12.0 14.0 28.2 - 310 1000 0.6 1050 - 0.5 70 56.7 24 208/230/1 22.6 35 377 - - 11 2, 3, 4 RTU -3 TRAINING 125A TRANE 14YCC4030A1070AI 2.0 DOWNFLOW Y Y DB FIELD N (3}1 80 67 85 12.0 14.0 1 24.6 - 200 800 1 0.6 1050 - 0.33 60 48.1 24 208/230/1 19.1 30 358 - - 1, 2, 3, 4 1: WIRING AND DISCONNECTS RY EC_ SINrJ F PnINT POWFR CnNNFr nnN_ 2: ECONOMIZER AND RELIEF DAMPER PROVIDED BY FACTORY AND INSTALLED BY M.C. 3: PROVIDE 7 -DAYS PROGRAMMABLE THERMOSTAT. 4: FRESH AIR INTAKE, AND REUEF/EXHAUST SHALL BE EQUIPPED WITH LOW LEAK (4 CFM/SQ.FT.), CLASS 1A MOTORIZED DAMPER THAT AUTOMATICALLY CLOSE DURING UNOCCUPIED HOURS. REVIEWED FOR CODE COMPLIANCE APPROVED .af - t SEP 1 2016 Cita' of Tukwila CI T''r 0 IF i UK�'VILr - SIa� 0 1 2015 SHEET TITLE PERMIT CENTER ALL Mms fff.SFRYE4 THESE ORAWiMGg saow IN ANY FIXW TO ma"Y7ARM. (D--- - o Orr i CE I'll 11L-6] Ti�!NINS 11'.�41 ICE 7---1 12x1 2 1' Z 12x1 2: CD tt 5 -b7T—YP.2)- 4-Tyl �2)- 0 -A" J.1 --Now f 1 . --40 x q W --A x18- TG T - ------ ---- E L - - ------ --- ---- - - jj- 8'0 r ON Imms\\- L V, W CD z 0 10 % ---100 -J y2" - T T EXISTING GAS --------- UNIT HEATER ri '/77[p ,Y2 " W01 - Wit 44 C4:9CE 0i . -1 W-1 j 120 2 ZD T 4 - t 0 YF2) "j, - --- -- it L I 1 Y t VE f LL %OE ho TEE T T LEVEL 1 HVAC PLAN SCNm Vw - T -T ,Y2 UNIT HEATER EXISTING GAS UNIT HEATER FOR-,* �TCRAGH I FT5- j 0 REVIEWED FOR CODE COMPLIANCE APPROVED D PPROVED SEP 13 2016 City of Tu ala BUILDING DIVISION RECEIVED CITY OF TUKWILA SEP 0 1 2016 PERMIT CENTER UNETYPE-LEGEND EXISTING CONSTRUCTION NEW CONSTRUCTION -------- DEMOUTION I ALL M01M RESERVED. M*n OMW,*M SIMOW Of MY FORK M "M"Y-P&W. HOLADAYmPA91% INC. SMART Mechanical Solutions e Mechanical Solutions e Energy Services Building Controls * Service & Maintenance 4600 S. 134TH PLACE SEATTLE, WA 98168 * (206) 248-9700 HOLADAYPARKS.com WA LICENSE NUMBER: HOLADPI379N0 "mmmmmmll PROJECT I < U) C) Lo Z: cn Lo ,,I - DESIGN TEAM Designed bv: MC Drawn by: MLK, MV Approved by: Job Number 43702 Filename: M201.DWG REGISTRATION 8/31/20`16 APPROVED FOR CONSTRUCTION I ISSUE NANIMATE I PENDING CITY APPROVAL PERMIT ISSUE 8/31/2016 R-VISIONS_tf""""""""""""" No. Date By Description 1 8/31/2016 RL PERMIT / CD ISSUE SHEET TITLE LEVEL 1 HVAC PLAN --I SHEET NUMBER F' M2.01 W REPRODUCED IN ANY FOM OR BY ANY MEANS VMH= PE"SSM INWFdWO FROM HMADAY MOM W- o_ - TOP OF CURB MUST BE LEVEL & FLAT (SEE NOTES 1 & 2) 2x6 WOOD BACKING BY G.C. 16 GAUGE ROOF CURB (BY A/C MFG.) ml 0 4- WIDIT � 16GA SEISMIC RESTRAINTS QUANTITY AND CONNECTION PER TABLE BELOW No. 10)�i,-' SCREW SEAL &' AikE WATERTIGHT STOP ROOFING FELT._ BEFORE CURB LIP SHEETMETAL FLASHING INSTALLED OVER ROOFIN( FELT. (BY MECH.) BUILT—UP ROOFING (SEE NOTE 5) APPROXIMATE ED OF / BY G.C. i ROOF OPENING CANT STRIP (SEE NOTE 3) X,\ (SEE NOTE 5) ROOF DECK NOTES: 1. GENERAL CONTRACTOR SHALL PROVIDE SHIMS AS REQUIRED TO MAKE CURB LEVEL MAXIMUM ALLOWABLE SLOPE IS %4- PER 10'. 2. TOP OF CURB MUST BE TRUE (FLAT) TO PROVIDE AN ACCEPTABLE SEALING SURFACE. 3. ROOF STRUCTURE, ROOF DECK, INSULATION, CANT STRIP & BUILT—UP ROOFING BY GENERAL CONTRACTOR. 4. STRUCTURAL MEMBERS MUST NOT INTERFERE kATH ROOF OPENINGS. 5. FASTEN ROOF CURB SECURELY TO STRUCTURAL MEMBERS. kJJ78 w Ana ovua FASTENER SCHEDULE Lo EQUIP. SVM. UNI DIMENSIONS L I W H WEIGHT LBS. OF 16GA STRAPS OF FAST. INSIDE OF CURB DIMENSIONS PER STRAP(D L I W H WEIGHT RTU -1 49' 43' 35.5" 377 6 6 43.5' 36' 14- — RTU -2 49' 43' 35.5" 377 6 6 43.5" 1 36' 14" — RTU -3 49' 43' 35.5" 358 6 6 43.5' 36` 14" — (D SEE STRAP DETAIL FOR FASTENER TYPE AND SIZE DETAIL - CURB WITH SEISMIC RESTRAINT SCAE- NM 0 STRUCTURAL CALCULATION PROVIDED BY OTHERS IF REQUIRED BY CODE OFFICIAL , REVIEWED FOR 466E COMPLIANCE ' APPROVED ' SEP 13 2016 City ofrukvwita BUILDING DIVISION RECEIVEC) CIT`: OF TUKWILA SES 0 9 2416 PERMIT CENTER EXISTING CONSTRUCTION NEW CONSTRUCTION DBAOUTION AU III" S RESERVED. THESE MA`MNCi4 BELONG 114 ANY FOM TO HOtADAY-PAFM. NO.. NO PAW OF THS HOLADAY m SMART Mechanical Solutions Mechanical Solutions . Energy Services Building Controls s Service & Maintenance 4600 S. 134TH PLACE SEATTLE, WA 98168 . (206) 248-9700 HOLADAYPARKS.com WA LICENSE NUMBER: HOLADPI379NO PROJECT DESIGN TEAM Desiuned bv: MC Drawn by: MILK, MV Approved by: Job Number. 43702 Filename: M2RF.DWG REGISTRATION 8/31/2016 APPROVED FOR CONSTRUCTION ISSUE NAMFJDATE PENDING CITY APPROVAL PERMIT ISSUE 8131/2016 11 REVISIONS No. Date By Description 1 8/31/2016 RL PERMIT / CD ISSUE SHEET TITLE ROOF HVAC PLAN SHEET NUMBER FPIOM HOLIDAY PAW. BIG Lo Lo DESIGN TEAM Desiuned bv: MC Drawn by: MILK, MV Approved by: Job Number. 43702 Filename: M2RF.DWG REGISTRATION 8/31/2016 APPROVED FOR CONSTRUCTION ISSUE NAMFJDATE PENDING CITY APPROVAL PERMIT ISSUE 8131/2016 11 REVISIONS No. Date By Description 1 8/31/2016 RL PERMIT / CD ISSUE SHEET TITLE ROOF HVAC PLAN SHEET NUMBER FPIOM HOLIDAY PAW. BIG