Loading...
HomeMy WebLinkAboutPermit M16-0143 - KING COUNTY HOUSING AUTHORITY - ROOFTOP AHUKING COUNTY HOUSING AUTHORITY X11 � 1t •. M16-0143 City of Tukwila ' Department of Community Development • 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Inspection Request Line: 206-438-9350 Web site: http://www.TukwilaWA.Rov MECHANICAL PERMIT Parcel No: 2623049123 Permit Number: M16-0143 Address: 600 ANDOVER PARK W Issue Date: 10/4/2016 Permit Expires On: 4/2/2017 Project Name: KING COUNTY HOUSING AUTHORITY Owner: Name: KC HOUSING AUTHORITY Address: 600 ANDOVER PARK W, TUKWILA, WA, 98188 Contact Person: Name: KEN CARLSON Phone: (253) 627-8155 Address: 2701 S J ST, TACOMA, WA, 98409 2014 Contractor: 2015 Name: GENERAL MECHANICAL INC Phone: (253) 627-8155 Address: 2701 SOUTH J ST, TACOMA, WA, 2015 98409 2014 License No: GENERM*306QF Expiration Date: 9/30/2018 Lender: 2015 Name: 2015 Address: DESCRIPTION OF WORK: CHANGE ROOFTOP AHU Valuation of Work: $120,000.00 Fees Collected: $1,637.62 Type of Work: REPLACEMENT Electrical Service Provided by: PUGEST SOUND ENERGY Fuel type: GAS Water District: TUKWILA Sewer District: TUKWILA Current Codes adopted by the City of Tukwila: International Building Code Edition: 2015 National Electrical Code: 2014 International Residential Code Edition: 2015 WA Cities Electrical Code: 2014 International Mechanical Code Edition: 2015 WAC 296-466: 2014 Uniform Plumbing Code Edition: 2015 WA State Energy Code: 2015 International Fuel Gas Code: 2015 Permit Center Authorized Signatu Date: " I hearby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this development permit and agree to the conditions attached to this permit. Signature: �� Date: %U — PrintName: This permit shall become null and void if the work is not commenced within 180 days for the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. PERMIT CONDITIONS: 1: Work shall be installed in accordance with the approved construction documents, and any changes made during construction that are not in accordance with the approved construction documents shall be resubmitted for approval. 2: All permits, inspection record card and approved construction documents shall be kept at the site of work and shall be open to inspection by the Building Inspector until final inspection approval is granted. 3: Readily accessible access to roof mounted equipment is required. 4: All construction shall be done in conformance with the Washington State Building Code and the Washington State Energy Code. 5: Remove all demolition rubble and loose miscellaneous material from lot or parcel of ground, properly cap the sanitary sewer connections, and properly fill or otherwise protect all basements, cellars, septic tanks, wells, and other excavations. Final inspection approval will be determined by the building inspector based on satisfactory completion of this requirement. 6: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206-431-3670). 7: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center. 8: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. 9: ***MECHANICAL PERMIT CONDITIONS*** 10: All mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center (206/431-3670). 11: Manufacturers installation instructions shall be available on the job site at the time of inspection. 12: The attached set of mechanical plans have been reviewed by The Tukwila Fire Marshals Office and are acceptable with the following concerns: 13: H.V.A.C. units rated at greater than 2,000 cfm require auto -shutdown devices. These devices shall be separately zoned in the alarm panel and local U.L. central station supervision is required. (City Ordinance #2437) 14: H.V.A.C. systems supplying air in excess of 2,000 cubic feet per minute to enclosed spaces within buildings shall be equipped with an automatic shutoff. Automatic shutoff shall be accomplished by interrupting the power source of the air -moving equipment upon detection of smoke in the main return -air duct served by such equipment. Smoke detectors shall be labeled by an approved agency for air -duct installation and shall be installed in accordance with the manufacturer's installation instructions. (IMC 606.1, 606.2.1) 15: Remote indicator lights are required on all above ceiling smoke detectors. (City Ordinance #2437) 16: Duct smoke detectors shall be capable of being reset from a single point near the alarm panel. (City Ordinance #2437) 17: Duct detectors shall send a supervisory signal only upon activation. (City Ordinance #2437) 18: All new fire alarm systems or modifications to existing systems shall have the written approval of The Tukwila Fire Prevention Bureau. No work shall commence until a fire department permit has been obtained. (City Ordinance #2437) (IFC 901.2) 19: An electrical permit from the City of Tukwila Building Department Permit Center (206-431-3670) is required for this project. 20: Contact The Tukwila Fire Prevention Bureau to witness all required inspections and tests. (City Ordinances #2436 and #2437) 21: Any overlooked hazardous condition and/or violation of the adopted Fire or Building Codes does not imply approval of such condition or violation. 22: These plans were reviewed by Inspector 511. If you have any questions, please call Tukwila Fire Prevention Bureau at (206)575-4407. PERMIT INSPECTIONS REQUIRED Permit Inspection Line: (206) 438-9350 1400 FIRE FINAL 0703 MECH EQUIP EFF 1800 MECHANICAL FINAL 0609 PIPE/DUCT INSULATION 0705 REFRIGERATION EQUIP 0701 ROUGH -IN MECHANICAL 0702 SMOKE DETECTOR TEST CITY OF TUKWi" Community Development Department Permit Center • 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://www.TukwilaWA.Jzov Mechanical Permit No.� O l Project. No. Date Application Accepted: Date Application Expires: (For office use only MECHANICAL PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. **please print** SITE LOCATION �—o Site Addrl Tenant Q t-j42�— -�� i&- PROPERTY OWNER Nart� z Address: City: tate: i CONTACT PERSON — person receiving all proiect communication z Name: S -J— ` a 9M Address: � Fax: City: State- p: Tukwila Business License No. /2 Phone: Fax: -7z Email: Lr Valuation of project (contractor's bi, Describe the scope of work in detail id, or's Tax No.: Number: Floor: New Tenant: ❑ ..... Yes 11�-No MECHANICAL CONTRACTOR INFORMATION Company Name: z Address:. I S -J— City: State: Zip;6*5 Phone: , Fax: Contr Reg No.: /r e Exp Date: Tukwila Business License No. /2 Use: Residential: New.......... ❑ Replacement........ ❑ Commercial: New.......... ❑ Replacement...... ,ET— Fuel Type: Electric...... ❑ Gas .... Other: H:\Applications\Forms-Applications On Line\2016 ApplicationsNechanical Permit Application Revised 1-4-16.docx Revised: January 2016 Page 1 of 2 bh Indicate type of mechanical work being installed and the quantity below: Unit Type Qty Furnace <100k btu Residential, Nighttime Furnace >100k btu Industrial Floor furnace 55 dB(A) Suspended/wall/floor 57 dB(A) mounted heater Commercial Appliance vent 47 dB(A) Repair or addition to 65 dB(A) heat/refrig/cooling 60 dB(A) system 65 dB(A) Air handling unit <10,000 cfm Unit Type Qty Air handling unit >10,000 cfm Residential, Nighttime Evaporator cooler Industrial Ventilation fan connected to single duct 55 dB(A) Ventilation system 57 dB(A) Hood and duct Commercial Incinerator — domestic 47 dB(A) Incinerator — comm/industrial 65 dB(A) Unit Type Qty Fire damper Residential, Nighttime Diffuser Industrial Thermostat 55 dB(A) Wood/gas stove 57 dB(A) Emergency enerator Commercial Other mechanical equipment 47 dB(A) 60 dB(A) 65 dB(A) Boiler/Compressor Qty 0-3 hp/100,000 btu 3-15 h /500,000 btu 15-30 hp/1,000,000 btu 30-50 hp/1,750,000 btu 50+ h /1,750,000 btu Noise Mechanical units need to be in compliance with the Tukwila Noise Code. Maximum permissible sound levels are based on from where the sound is created and where the sound is heard. Additionally, if sound can be heard from within a house at night in a residential zone it may not be allowed. For more details, see TMC 8.22 District of Sound Producing Source District of Receiving Property Residential, Da time* Residential, Nighttime Commercial Industrial Residential 55 dB(A) 45 dB(A) 57 dB(A) 60 dB(A) Commercial 57 dB(A) 47 dB(A) 60 dB(A) 65 dB(A) Industrial 60 dB(A) 50 dB(A) 65 dB(A) 70 dB(A) *Daytime means 7AM-I OPM, Monday through Friday and 8AM-IOPM, Saturday, Sunday and State -recognized holidays. A few sounds are exempt from the noise code, including: Warning devices; Construction and property maintenance during the daytime hours (7am-10pm); Testing of backup generators during the day. PERMIT APPLICATION NOTES - Value of construction — in all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the permit center to comply with current fee schedules. Expiration of plan review — applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The building official may grant one extension of time for additional periods not to exceed 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNJKR OR Print AGENT: Date: Z T' Day Telephone :2C -e —6Z 7—�j(S—j Mailing Address: 27, S• '16"720'J City State Zip H:\Applications\Forms-Applications On Line\2016 ApplicationsWechanical Permit Application Revised 1-4-16.docx Revised: January 2016 Page 2 of 2 bh DESCRIPTIONS PermitTRAK $1,637.62 M16-0143 Address: 600 ANDOVER PARK W Apn: 2623049123 $1,637.62 MECHANICAL $1,574.63 PERMIT ISSUANCE BASE FEE R000.322.100.00.00 0.00 $32.50 PERMIT FEE R000.322.100.00.00 0.00 $1,227.20 PLAN CHECK FEE R000.322.102.00.00 0.00 $314.93 TECHNOLOGY FEE $62.99 TECHNOLOGY FEE TOTAL FEES PAID BY RECEIPT: R9392 R000.322.900.04.00 0.00 $62.99 $1,637.62 Date Paid: Monday, September 12, 2016 Paid By: KENNETH CARLSON Pay Method: CREDIT CARD 012108 Printed: Monday, September 12, 2016 11:57 AM 1 of 1 N?WY57EM5 INSPECTION RECORD e A/) Retain a copy with permit IMI (A Oi�� INSPEt4<N N0. PERMIT N0. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Project: Type of Inspection: WIA ac'l�tL 1� L Address: Date Called: M2 reK Special Instructions: Date Want d: a. p.m. Request9f: Phone No: 2S -S;- 6owl - CL. Approved per applicable codes. O Corrections required prior to approval. COMMENTS: Inspector: Date11117116 r 7 16 REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. INSPECTION RECORD Retain a copy with permit I& - O/ 3 INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Project: TyRe of Inspection: - Address: n JkO .UJI�' Date Called: Special Instructions: Date Wanted: -711 p.m. Requester: Phone No: 0 Approved per applicable codes. LJ Corrections required prior to approval. Date: I M REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. INSPECTION RECORD.r2) �� Retain a copy with permit INS ION N0. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 FlApproved per applicable codes. 1:1 Corrections required prior to approval. COMMENTS: Inspector: Date: %� , � 61 1 F] REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. 0 INSPECTION RECORD I(n `0/q - Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Project- )�CA A Type of Inspection: AjeCP Address: /� 1-17Uii 1/ OA -W- JAI Date Called: Special Instructions: Date Want a.m. //77/9 p.m. lRequestqf: Phone No: WApproved per applicable codes. Corrections required prior to approval. COMMENTS: Inspector: A>Aim Date:/ 4 -7 //4; REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. 01 INSPECTION RECORD Retain a copy with permit M 1 &- 6 hj 3 INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 FlApproved per applicable codes. Corrections required prior to approval. REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. INSPECTION RECORD Retain a copy with permit INSPECTION NUMBER PERMIT NUMBERS CITY OF TUKWILA FIRE DEPARTMENT 206-575-4407 Project: Type of Inspection:14 / Address: Contact Person:' Suite #: Pre -Fire:. Special Instructions: Phone No.: ❑ Approved per applicable codes. COMMENTS: ❑ Corrections required prior to approval. Needs Shift Inspection: Sprinklers: Fire Alarm: Hood & Duct: Monitor: Pre -Fire:. Permits: Occupancy Type: Inspector: m I Date: fl/tI116 Hrs.: ❑ $100.00 REINSPECTION FEE REQUIRED. You will receive an invoice from the City of Tukwila Finance Department. Call to schedule a reinspection. tsming Aaaress Attn: Company Name: Address: City: State: Zip: Word/Inspection Record Form.Doc 3/14/14 T.F.D. Form F.P. 113 PERMIT COORD COPY PLAN REVIEW/ROUTING SLIP PERMIT NUMBER: M16-0143 DATE: 09/14/16 PROJECT NAME: KING COUNTY HOUSING AUTHORITY SITE ADDRESS: 600 ANDOVER PARK W X Original Plan Submittal Revision # before Permit Issued Response to Correction Letter # Revision # after Permit Issued DEPARTMENTS: � L ���(04� Building Division Public Works ❑ PRELIMINARY REVIEW: Not Applicable ❑ (no approval/review required) REVIEWER'S INITIALS: APPROVALS OR CORRECTIONS: Approved ❑ Corrections Required ❑ (corrections entered in Reviews) Notation: REVIEWER'S INITIALS: lfw( P, A-�A - -,� -�I� Fire Prevention Ii Planning Division ❑ Structural ❑ Permit Coordinator ❑ DATE: 09/15/16 Structural Review Required ❑ DATE: DUE DATE: 10/13/16 Approved with Conditions Denied ❑ (i.e: Zoning Issues) I 13r.11 I is Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: 12118/zms GENERAL MECHANICAL INC. Home Espanol Contact Safety & Health Claims & Insurance 40*4 Washington State Department of Ch Labor & Industries GENERAL MECHANICAL INC Owner or tradesperson 2701 SOUTH J STREET TACOMA, WA 98409-8092 Principals 253-627-8155 CAMPBELL, MATTHEW R, PRESIDENT PIERCE County LONSFORD, MICHAEL C, VICE PRESIDENT HOOVER, STEPHEN ROSCOE, VICE PRESIDENT SMITH, ADAM THOMAS, SECRETARY HOOVER, DALE E, VICE PRESIDENT (End: 08/25/2014) BOYCE, ALAN T, VICE PRESIDENT (End: 08/25/2014) KEMPF, DANIEL A, SECRETARY (End: 09/06/2016) MANLEY, PETER T, PARTNER (End: 10/01/1998) COLEMAN, JAMES P, PRESIDENT (End: 10/01/2003) Doing business as GENERAL MECHANICAL INC WA UBI No. Business type 278 040 974 Corporation Governing persons ALAN T BOYCE DALE E HOOVER; MATTHEW CAMPBELL; MICHAEL LONSFORD; License Page 1 of 3 Search A -"L Index Help Roy U-1 Workplace Rights Verify the contractor's active registration / license / certification (depending on trade) and any past violations. Construction Contractor Active. ... _.........._................................ _..................... Meets current requirements. License specialties GENERAL License no. GENERM*306QF Effective — expiration 11/06/1970— 09/30/2018 Bond ............... Safeco Ins Co of America Bond account no. 69S000624 $12,000.00 Trades & Licensing Help us improve https:Hsecure.lni.Wa.gov/verify/Detail.aspx?UBI=278040974&LIC=GENERM*306QF&SAW= 10/4/2016 J A r C E G H i K L 5 P 7 6 10 E 11 PROJECT NOTES OMER: KING COUNTY HOUSING AUTHORITY (ANDOVER PARK WEST` TUKWILLA, 98188 CONTRACTOR: JOHNSON CONTROLS 4011 S.E. INTERNATIONAL WAY SUITE 605 MILWAUKEE, OR 97222 PROJECT MANAGER: VEERA VIJAY P.E. CEM 206_85D.A742 Yee ramijayaraghavanfti.cam ENGINEER: HULTZIBHU ENGINEERS 1111 FAWCETT AVENUE SUITE 100 TACOMA, WA 98402 PRIMEIMECHANICAL CONTACT: MICHAEL TAGLES, P.E. ELECTRICAL CONTACT: TOM URQUHART, RE STRUCTURAL ENGINEER: PCS STRUCTURAL SOLUTIONS 1250 PACIFIC AVE #7071 TACOMA. WA 98402 253.383.3257 FAX: 253.3$3.32$3 michaatt@)huhzbhu.com 251383.3257 FAX: 253.383.328 tomu@hultzbhb.com CONTACT; GARY BECKNER: P E 253-383.2797 GbL-ckner@psc-stL,ctural.com F— PROJECT GENERAL NOTES 1 ALL ITEMS ARE NEW UNLESS SPECIFICALLY NOTED AS EXISTING, 2 ALL WORK IS 13ASE BID UNLESS SPECIFICALLY NOTED AS ALTERNATE BID WORK. 3. REVIEW OF EXISTING CONDITIONS IS REQUIRED. 4. BUILDING IS OCCUPIED DURING CONSTRUCTION, UTILITY OUTAGES MUST BE AUTHORIZED BY OWNER, NO NOISE GENERATING ACTIVITIES BSPAIEEN 5 Phi AND 7 AM F DESCRIPTION OF WORD REPAIR HVAC SYSTEM AT MULTIPLE SITES IN KING COUNTY, LIST OF DRAWINGS G1.0 COVER SHEET MA)N OFFICE - (MO) M041,10.1 MECHANICAL LEGEND & NOTES MO -M1:0 SCHEDULES & SPECIFICATIONS MO -M4.0 ROOF PLAN MO -M4.1 DETAILS BRIAFRWOOD - (BVV) W.1 !,MECHANICAL LEGEND & NOTE -WO SCHEDULES & SPECtFICATTIO S SE— IAR.,T E P - ,`SIT l Olr,1Is' :-:D FOR: 0 IN-lechanica! 13,6cctrical 0 -Plumbing `J<✓`-`" pvmg 7 C-17 Cf Tulaw"'.a 5 no M4.0 ROOF PLAN YA-M1: SCHEDULES b SPECIR ATIONS LA OUSE - (LH) ROOF PLAN FRE COPY LH -#M0. MECHANICAL LEGEND QTES ,44x11.0 SCHEDULES & SPECIFICATIO LH -M1. SCHEDULES & SPECIE ATIONS�■ Perm 1 D LH -M4.0 ROOF PLAN .-M[.L NQRTiIRI N1-MO.1 1 -(N1) I CHANICAL LE ND & NOTES Flan ioYi3�1V �s ilC�%Pi !9 subject 1 ct to errors and omissions. N1 -M1.0 SC EDULES & ECIFICATIONStf-;r0'2I cf co 'Siri_�-:{ion documents does not aul:hoCize NI -WO R PLAN the Viciation Li ,.ny adopted code or ordinance. Pii000ipt N2 -M0,1 b(3E 2 . ( ) N2 -M0,1 MEGHAI LEGEND 8 NOTES of a f'ovod F, ., FP " � -- � •� d Copy and condiiaons is acknowledged: N2 -M1 o SCHEDU S & SPECIFICATIONS N2 -M4.0 ROOF By: SOUTHRIDGE H SE-( ) Date: — �� SR-MO.1 ME ICAL L GENA & NOTES z SR1.0 EDULES & S ECIFICATIONS SR:M?,14.0 F PLAN City of Tukwila YARDLEY RIMS - (YA) BUILDING DIVISION "—"- YA--N10.1 MECHANICAL LEGEN & NOTES YA-M1: SCHEDULES b SPECIR ATIONS YA-M :0 ROOF PLAN TMINSTER MANOR - MIA) 1-M0.1 MECHANICAL LEGEND & NO S ,44x11.0 SCHEDULES & SPECIFICATIO -M4.0 ROOF PLAN i APPROVALS chan� _ ---- of w^ to the s^npP _ TL "?Proval of `visiOn_ m ay i '-3wpl n submittal rev; REVIEWED FOR CODE COMPLIANCE APPROVED t SEP 2 2 2016 City of Tukwila BUILDING DIVISION 9 RECEIVED CITY OF TUKWILA SEP 12 2016 PERMIT CENTER 10 PERMIT SET C4 a <m ' 63 Cn w IZ 0 t WN n CL w (D z LL W W 0-01 0 `. CL ' _z LEO SIGNED d3.03-2DiS� t0 W z z Q � x cn W o a W e- I -- O Z e T W V3 C3 Q tL M, P/M S1 ET SIZE IS TRUE SCALE VN'I-EN: ASOVE LINS MEASURES AS NOTED J 0) 3 r 5 LTJ 7 �061 6 10 0 A B C Bellevue Jittl �,. WESY SEL t.EVj. � .j 1 ~ice .r Mercer Isimid ! CC) LUt UIt, Cir}' fi ' Newcastle ` t mount Regiol 7 7 �•� 4tr0rar7d White Center Coalfield ' Renton Highlands Tukwila 11x �.-=- 3 mapI 600 Andover Park W Heights - x SeaTac# Cascade-Faimood i1 Notmandy F rilt�a rt u Park t � East WJRK LOCATION VICR41TY SAP NTS F NORTH E I F I G I H AERIAL 'VIEW ^AR NTS NORTH SITE ADDRESS: KING COUNTY HOUSING AUTHORITY MAIN OFFICE 600 ANDOVER PARK WEST TUKWILLA, WA 98141 BLDG DATA: OCCUPANCY: R-2 (NO CHANGE) SPRINKLERED: YES (NO CHANGE) FIRE ALARM: YES (NO CHANGE) SCOPE OF WORK: 1 REPLACE EXISTING ELECTRIC ROOFTOP HVAC UNIT WITH NEW GAS FIRED ELECTRICAL COOL ROOFTOP HVAC UNIT E HA I AL E "ERAL DE OLITIO NOTES 1. DEMOLITION DRAWINGS NOTES ARE INTFNDED TO ONLY GIVE A GENERAL REPRESENTATION OF THE DEMOLITION INVOLVED, AND DO NOT CONSTITUTE A FULL LISTING OF ALL ITEMS REQUIRING REMOVAL NOT ALL ITEMS TO BE DEMO'D ARE SHOWN. CONTRACTOR IS RESPONSIBLE TO REVIEW EXISTING CONDITIONS. EXISTING DRAWINGS, AND MECHANICAL GENERAL DEMOLITION NOTES. 2 IT IS THE CONTRACTOR'S RESPONSIBILITY TO REVIEW SITE CONDITIONS AND TO IDENTIFY ALL DEMOLITION WORK, AND INCLUDE IN HIS BID ALL COSTS FOR DEMOLITION & DISPOSAL NOT ALL ITEMS TO BE DEMO'D ARE SHOWN: SEE GENERAL NOTES FOR REQUIREMI-NITS. 3. EXIST. DUCTS, EQUIPMENT. PIPING, AIR INLETSIOUTLETS, SHOWN DASHED REPRESENT MAJOR MECHANICAL. ITEMS TO 13E REMOVED SEE GENERAL NOTES. DRAWING NOTE=S 5 KEYED NOTES WHICH COVER ALL OTHER MISC. MECHANICAL ITEMS TO BE REMOVED. A ALL EXIST ITEMS NOT BEING REUSED SHALL BE REMOVED. THIS INCLUDES SUCH ITEMS AS THERMOSTATS, CONTROL DEVICES, CONTROL WIRING, PNEUMATIC TUBING, DUCTS, FANS, PIPING, SUPPORTS, VALVES, CURBS, AND RELATED ACCESSORIES. 5. PROVIDE TEMPORARY CAP -OFF OF ALL EXIST. SYSTEMS TO ALLOW CONTINUED USE OF ALL SYSTEMS UNTIL THE FINAL- SYSTEM COMPONENTS ARE INSTALLED AND CONNECTED S "OLD ALL REMOVED ITEMS FOR OWNERS REVIEW. ITE=MS SELECTED BY OWNE=R FOR SALVAGE SHALL BE MOVED BY THE CONTRACTOR TO THE OWNERS STORAGE ROOM (VERIFY EXACT LOCATION WITH OWNER). ITEMS NOT SELECTED BY OWNER FOR SALVAGE SHALL BE DISPOSED OF CFF SITE IBY CONTRACTOR. 7, ROUTING SHOWN OF EXISTING ITEMS IS APPROXIMATE= CONTRACTOR SHALL FIELD VERIFY LOCATIONS CONTENTS, AND FLOW DIRECTION OF ALL PIPING � DUCTS. LABELING SHOWN ON PLANS HAS NOT BEEN VERIFIED 8 _ SEE FLOOR PLANS FOR RECONNECTION OF NEW PIPING AND OUCTWORK. A I B I C I p I E I F K MECHANICAL LEGEND SYMBOL DESCRIPTION ABBREV. DESCRIPTION 201 p DUCT (FIRST FIGURE, SIDE SHOWN) AFF APPROX. ARCH AUTO) BOO 13TU BTUH BLDG C CAP CLG ABOVE FINISHED FLOOR APPROXIMATELY ARCHITECTURAL AUTOMATIC BACK DRAFT DAMPER BRITISH THERMAL. UNIT BRITISH THERMAL UNIT/HOUR BUILDING CONDENSATE CrAPACII Y CEILING 2a�2t 24„2t' LINED DUCT (DIM FOR NET FREE AREA) EOL= END i_' = r OF LINING TRICK LINING � R RISE (R) OR DROP ('D) ARROW IN DIRECTION OF FLOW cv DUCT SECTION (SUPPLY) ® DUCT SECTION (EXHAUST OR RETURN) 0 ROUND DUCT, DIAMETER CO CLEANOUT W Y VOLUME DAMPER (MANUAL) CONN CONNECTION Z CONT CONTINUE, CONTINUATION 0 a DAMPER CFM CUBIC FEET PER MINUTE LztMOTORIZED z DEG F, F° DEGREE FAHRENHEIT FLEXIBLE CONNECTION DIA, 0 DIAMETER DN DOWN BACK GRAFT DAMPER (BDD) DVVG DRAWING DS DRY BULB FLEXIBLE DUCT EA EACH EER EFF ELEC EOL ENERGY EFFICIENT RATIO EFFICIENCY ELECTRICAL, ELECTRIC END OF LINING FIRE DAMPER COMBINATION FIREISMOKE DAMPER II ELBOW WITH TURNING VANES XH EXIST. (E) EXHAUST EMSTING ���,ESts»�,t3at C� CEILING OUTLET' ESP FPM EXTERNAL STATIC PRESSURE FEET PER MINUTE CEILING INLET FLET{ FL FCC? FLA GAL GALV. GI HP INTEGR. IN KW MPEG MAX FLEXIBLE FLOOR FLOOR CLEAN OUT FULL LOAD AMPS GALLON GALVANIZED GREASE INTERCEPTOR HORSE POWER INTEGRAL INCH KILOWATT MANUFACTURER MAMMUM IStZE,sYMt3t>t. ---� WALL OUTLET (OR INLET) 7 OA G= WITH GUARD THERMOSTAT A= AVERAGED WITH OTHER (D SWITCH INTERVAL TIMER - - c -� ----- CONDENSATE LINE G GAS LINE MBH MECH THOUSAND BTUH MECHANICAL MIN MCA MINIMUM MINIMUM CIRCUIT AMPS MUA MAKE UP AIR MFS MINIMUM FUSE SIZE NIC NOT IN (CONTRACT NO, NUMBER NTS NOT TO SCALE OA OUTSIDE AIR OBD 0PP0$ED BLADE CLAMPER PH PHASE -PD PRESSURE DROP POC POINT OF CONNECTION RA RETURN AIR REF REFERENCE REO'D REOUIRED RLA RATED LOAD AMPS RPM REVOLUTIONS PER MINUTE RM ROOM $A SUPPLY AIR S.O. SCREEN OPENING TEMP TEMPERATURE TD TRANSFER DUCT TG TRANSFER GRILLE TYP TYPICAL UNC? UNLESS NOTED OTHERWISE V VF0 VOLTS. VOLTAGE, VENT VARIABLE FREQUENCY DRIVE WA WB WATT WET BULB 2 M3)�j DETAIL IDENTIFICATION NUMBER SHEET ON WHICH DETAIL IS SHOWN WL W1 WALL LOUVER WITH A SECTION IDENTIFICATION LETTER M3 �4 SHEET ON WHICH SECTION IS SHOWN i IE HA IAL GENERAL NOTES 1 ALL PIPING & DUCTWORK SHOWN IS SCHEMATIC. CONTRACTOR SHALL PROVIDE ALL OFFSETSIELBOWS AS REO'D TO ALLOW ROUTING AROUND STRUCTURE, ELECTRICAL, & OTHER INTERFERENCES 2. SALANCING NOTES: PROVIDE AIR BALANCING OF HVAC SYSTEM, SEE SECTION AND 23 05 93 FOR COMPLETE REGUIREMENTS 3 ALL PIPING AND DUCTWORK SHALL BE RUN CONGEALED, UNO h. PROVIDE TRANSITIONS FROM DUCT SIZES INDICATED TO CONNECTION SIZES AT EQUIPMENT. WHERE THE CONNEC;TINC; DUCT IS LINED, THE TRANSITION SHALL BE LINED USE Z' LINING (UNO) G it 2 3 a1 0 R u n s C') 0, a 0 ;Se Dzi�< W (000 ' C3) =--�Z z _~N. Lj%61- �- -- , Z10 WD �— I.L. _ILL 0 SIGNED 46.03-2016 Q) c C? L .. j C Uj tCi c� E ur E W2 x.o �w� f � C cv En .Q 2016 t s C') 0, a 0 ;Se Dzi�< W (000 ' C3) =--�Z z _~N. Lj%61- �- -- , Z10 WD �— I.L. _ILL 0 SIGNED 46.03-2016 Q) c C? W Uj F- MED w Y OZ C -UKWILA En L^t 2016 t .F I1.I W Y Z W 0 a LU F- z 9 c C? Uj MED w Y C -UKWILA En L^t 2016 t GENTER E` x= i r In i I _j K CI 10 0 J Co • ue 10 mr ROJ E OT PSE C I F ICIAATlOr4b 1. SECTION 23 1123 -GAS PIPING 2 STEEL PIPE FITTINGS. A THREADED FiTTLNGS• MALLEABLE IRON PER ASME B18 3- CAST IRON PER ASME 816.4. 3 GAS PIPING: SCHEDULE 40 STEEL PIPING {COMPLYING VMTH ASME A53} Wr~dTH THREADED CLASS 125 FITTINGS. 4. ZUL LISTED FOR GAS SERVICE. BRONZE TWO-PIECE BLOWOUT PROOF STEM, FULL PORT. NIBCO T -685 -70 -UL. 5. RATED AT MINIMUM 125 PSIG AT 200 DEGREES F; PROVIDE DIELECTRIC UNIONS WHERE DISSIMILAR METALS JOIN. PROVIDE UNIONS AT CONNECTIONS TO ALL EQUIPMENT 6. INSTALLATION: FOLLOW ESTABLISHED PROFESSIONAL PRACTICES FOR JOINING OF PIPING AND STT AS TO SUIT THE SYSTEM PRESSURES AND TEMPERATURES INVOLVED. 7. SECTION 23 81 53 - HVAC UNITS 8. HVAC UNITS ROOFTOP PACKAGED GAS HEAT ELECTERiC COOL ROOFTOP UNIT$ WITH AS A MINIMUM SCHEDULES CAPACITY. SEE SCHEDULE FOR ACCESSORIES MANUFACTURER AND MODELAS SCHEDULED. 9. PROVIDE WiTH 0-100% OA ECONOMIZER AND CUSTOM ROOF ADAPTOR CURB ENERMY COBE. - HVAC 1 LOAD CALCULATIONS HAVE BEEN PERFORMED IN ACCORDANCE WITH WSEC C4032.1..OR EQUIPMENT IS SELECTED AT SAME CAPACITY AS THE UNIT BEING REPLACED. 2 EQUIPMENT HAS BEEN SELECTSI3 PER WSEC 0403.2.2 3 VENTILATION AND THE ABILITY TO REDUCE OUTSIDE AIR TO IMG MINIMUM$ SHALL BE PROViDED PER WSEC 0403 2 5. 4 MOTORS i HP AND LARGER SHALL BE ENERGY EFFICIENT TYPE PER VVSEC C403.2.13: MOTORS 1112 HP TO 1 HP SHALL BE EiCM *TYPE OR MEET L41NIMUM EFFICIENCY REQUIREMENTS PER WSEC C403.2.10.3. S. TEMPERATURE CONTROL SYSTEM SHALL HAVE A MINIMUM DEAD BAND OF 5 DEGREES AS REQUIRED BY WSEC 0403.2.4.2. 6. HVAC SYSTEMS SHALL BE EQUIPPED VIATH AUTOMATIC CONTROLS CAPABLE OF PROVIDING NIGHT SETBACK. SEVEN DIFFERENT DAILY SCHEDULES, AND OPTIMUM START PER THE REQUIREMENTS OF WNSEC C403.2 4.3 7 OUTSIDE AIR INTAKES, EXHAUST OUTLETS, AND RELIEF OUTLETS SHALL BE PROVIDEDWMTH DAMPERS THAT COMPLY WITH WSEC C403.2.4.4. DAMPER SHALL AUTOMATLCALLY CLOSE VVI-IEN SYSTEM OR SPACES SERVED ARE NOT IN USE OR DURING WARM-UP. COOL4)OWN, AND SETBACK DAMPER MAXIMUM LEAKAGE RATE SHALL NOT EXCEED MAXiMUM ALLOWED BYVVSf:C 0402.4.52 a COMBUSTION HEATING EQUIPMENT WITH A CAPACITY OVER 225 MBH SHALL HAVE MODULATING OR STAGED COMBUSTION CONTROL PER WSEC C+403.Z4.6. 9. FAN SYSTEMS SERVING A ZONE OR MULTIPLE ZONES WViTHOUT SEPARATING WALLS WMTH TOTAL AIRFLOVV OVER 10,E: W CFM SHALL REDUCE AIRFLOWWi BASED ON SPAC E HEATING AND COOLING DEMAND PER WSEC 0403.2.122 10. ALL DUCTIM(3RK SHALL BE CONSTRUCTED AND SEALED IN ACCORDANCE VATH IMC, MEC C402 AND LSC REQUIREMENTS PER MEC C403.2.7. 11 DUCTS AND PLENUMS DESIGNED TO OPERATE AT A PRESSURE ABOVE 3' W.C. SHALL BE LEAK TESTED PER WNSSC 0403.2 7.3.3. DOCUMENT AND SUBMIT TEST RESULTS TO THE AHJ AS REQUIRED 12. DUCTWORK SHALL BE INSULATED TO THE APPROPRIATE R -VALUE AS REQUIRED BYyti EC 0403.2 7. 13 PROVIDE HIGH LIMiT SHUT-OFF CONTROL OF ECONOiySIZER COOLING PER TABLE C403.3.1.1.3(2) 14 ECONOMIZER DAMPERS SHALL BE CAPABLE OF BEING SEQUENCED WITH MECHANICAL COOLING EQUIPMENT. ECONOMIZERS ON SYSTEMS WViTH COOLING CAPACITY GREATER THAN 65 MBH SHALL BE CAPABLE OF PROVIDING PARTIAL COOLING PER MEC 0403.3.1.1.2 15. ECONOMIZER CONTROLS SHALL BE SUCH THAT ECONOMIZER OPERATION DOES NOT INCREASE BUILDING HEATING ENERGY DURING NORMAL OPERATIONS PER WSEC C403,4.1.4, AND SHALL BE INTEGRATED WITH MECHANICAL COOLING SYSTEM AND BE CAPABLE OF PROVIDING PARTIAL COOLING PER WSEC 0403.4.1.3 16. FORVAV SYSTEMS WITH ODD, PROVIDE STATIC PRESSURE RESET PER VWSEC 0403.4.2.2 17. SUPPLY ALR SYSTEMS SERVING MULTIPLE ZONES SHALL BE VAV TYPE DESIGNED AND CAPABLE OF $EING CONTROLLED TO REDUCE PRIMARY AiR SUPPLY TO EACH ZONE TO A MAXIMUM FLOW RATE AS ALLOWED BY WSEC 0403 4 5. IS. HVAC SYSTEMS NTH MULTIPLE ZONES SHALL REQUIRE TEMPERATURE RESET CONTROLS MICH AUTOMATICALLY RESET SUPPLY AIR TEMPERATURES PER WSEC 0403.4.5.4. 19. COOLING SYSTEMS SHALL. NOT USE HOT GAS BYPASS OR OTHER EVAPORATOR PRESSURE CONTROL SYSTEMS UNLESS THERE ARE MULTIPLE STEPS OF UNLOADING, HOT GAS BYPASS CAPACITY SHALL BE LIMITED PER TABLE 0403.4.7. DOES NOT APPLY TO UNITARY PACKAGED SYSTEMS 90 MBH OR SMALLER 20. AIR SHALL BE BALANCED AS REQUIRED IN SECTION 0408 2.21 AND C408.2.2 2 OF THE WSEC 21. PROVIDE COMMISSIONING PLAN 8 REPORT REQUIREMENTS FOR PRELIMINARY MID FiNAL COMMISSION048 PER SECTION C408.1. PROVIDE SECiLIENCE OF OPERATIONS AND TEST PROCEi3URES PER SECTION C•4U6.1.2 AND SUBMIT COMPLIANCE CHECKLIST PER SECTION 0108.1 3 4 OF THE WSEC TO THE BUILDING OFFICiAL UPON SUBSTANTIAL COMPLETION. 22. THESE'ENERGY CODE NOTES' ARE LiSTED TO SATISFY THE BUILDING DEPARTMENTS REQUIREMENT THAT CERTAIN INFORMATION BE PLACED ON THE PIANS, BUT DO NOT DIMINISH THE FULL PROJECT REQUIREMENTS PROVIDE ITEMS IN EXCESS OF CODE WHERE NOTED ON DRAWINGS AND IN SPECIFICATIONS. FOR OTHER ADDED REQUIREMENTS, SEE SPECIFICATIONS. SECTION 010000 -GENERAL 1. CODE CCMPLIANCE- ALL WORK SHALL COMPLY WITH ALL LOCAL CODES AND ORDINANCES 2 DRAW NGS. DRAW NGS ARE DIAGRAMMATIC AND SHOWN THE GENERAL ARRANGEMENT OF THE CONSTRUCTION, AND THEREFORE DO NOT SHOW ALL NECESSARY OFFSETS, FITTINGS, ALTERATIONS TO EXISTING ITEMS, AND ACCESSORIES WHICH ARE REQUIRED TO FORM COMPLETE AND OPERABLE SYSTEMS. 3 FIELD VERIFICATION: THE CONTRACTOR SHALL BE RESPONSIBLE FOR CHECKING FIELD CONDITIONS AND VERIFYING ALL MEASUREMENTS AND RELATIONSHIPS INDICATED ON THE DRAWINGS BEFORE SUBMITTING BIDS AND AGAIN BEFORE PROCEEDING WITH THE WORK 4. NOTiFY THE ARCH ITECT1ENGINEER OF ANY CiISCREPANCIES OR CONFLICTS BEFORE PROCEEDING WITH ANY MRK OR THE PURCHASING OF ANY MATERIALS FOR THE ARENS) OF CONFLICT UNTIL REQUESTING AND OBTAINING VVR ITTEN INSTRUCTIONS FROM THE ARCHITECTIENGINEER ON HOWTO PROCEED. WHERE CONFLICTS OCCUR, THE MOST EXPENSIVE AND STRINGENT REQUIREMENT(AS JUDGED BYTHE ARCHiTEICTIENGiNEER) SHALL PREVAIL. ANY WORKDONE AFTER DiSC,0VERY OF SUCH DISCREPANCIES OR CONFLICTS AND PRIOR TO OBTAINING THE ARCHITECTIENGINEER'S INSTRUCTIONS ON HOW TO PROCEED SHALL BE DONE AT THE CONTRACTOR'S EXPENSE. 5 DRAVWiNGS AND SPECIFICATIONS. DRAWINGS AND SPECIFICATIONS ARE COMPLEMENTARY AND WHAT IS CALLED FOR IN EITHER IS BINDING AS IF CALLED FOR IN BOTH. THE DRAWINGS ARE DIAGRAMMATIC AND SHOWTHe OENeRAL ARRANGEMENT OF THE CONSTRUCTION AND THEREFORE DO NOT SHOWALL- OFFSETS, FITTINGS AND ACCESSORIES MICH ARE REQUIRED TO FORM A COMPLETE AND OPERATING INSTALLATION. MECHANICAL WORK IS SHOWN ON MULTIPLE DRAWNNOS AND IS NOT LIMITED TO A PARTICULAR SET OF SHEETS, OR SHEETS PREFACED VOTH A PARTICULAR LETTER. 6. PERMITS AND FEES: THE CONTRACTOR SHALL OBTAIN AND PAY FOR ALL PERMITS. LICENSES, FEES AND INSPECTIONS AS REQUIRED 6Y THE GOVERNING CODES AND AS SPECIFIED HEREIN. 7. SUBMITTALS: CONTRACTOR SHALL SUBMIT SHOP DRAWW INGS FOR ALL PRODUCTS PROPOSED TO BE USED ON THIS PROJECT FOR OWNER REVIIEW- PRODUCTS SHALL NOT BE USED UNTIL APPROVED BY THE OVWMER OR HIS REPRESENTATIVE. SUBMIT 3 COPIES PLUS ANYADVITiONALQUANTITIES THE CONTRACTOR NEEDS (3 COPIES %MLL BE RETAINED BY THE OWNER). 6 RECORD DRAWINGS: THE CONTRACTOR SHALL MAINTAIN A SET OF CONTRACT PLANS AT THE PROJECT SITE UPON WHICH ALL CHANGES FROM THE AS -BID PLANS ARE NOTED. AT THE. COMPLETION OF THE PROJECT, THE CONTRACTOR SHALL DELIVER TO THE OWNER ONE COMPLETE SET OF THESE RECORD DRAWINGS. 9. PROTECTION: CONTRACTOR IS RESPONSIBLE FOR PROTECTION OF ALL MATERIAL, FOUIPMENTANDAPPARATUS PROVIDED UNDER THIS SECTION FROM DAMAGE. WATER, CORROSION, FREEZING AND DUST, BOTH IN STORAGE AND WHEN INSTALLEO, UNTIL FINAL PROJECT ACCEPTANCE 10 COORDINATION THE CONTRACTOR SHALL COORDINATE ALL CONSTRUCTION ACTIVITIES WITH THE OWNER AND COOPERATE FULLY SO AS TO MINIMIZE CONFLICTSAND TO ALLOW FULL OWNER USAGE (UNLESS INDICATED OTHERWIWiSE) OF ALL AREAS DURING CONSTRUCTION 11. CUTTING AND PATCHING: SHALL BE DONE BY SKILLED LA13OR EXPERIENCED IN PROVIDING OPENINGS AND PATCHING OF THE MATERIALS INVOLVED. AREAS SHALL BE PATCHEDAND RESTORED TO AFiNISHEO CONDITION, EQUAL TO ADJACENT FINAL FINISHED AREAS THAT HAVE NOT BEEN CUT 12. PAINTING: SHALL BE PROVIDEO VMERE INDICATED, BY SKILLED PAINTERS IN CONFORMANCE WITH STANDARD PROFESSIONAL PRACTICE INCLUDING CLEANING AND PRIMING OF MATERIALS TO BE PAINTED. COLORS SHALL BE SELECTED BY THE OWNER 13. FINAL INSPECTION: PRIOR TO ACCEPTANCE OF THEWORK THE CONTRACTOR SHALL PUT ALL SYSTEMS INTOOPERATION FORA PRRIOD OF NOT LESS THAN S WORKING DAYS 60 THAT THEY MAY BE INSPECTED BY THE OVWER. 14 INSTRUCTION! O S M MANUALS: DURING THE FINAL iNSPECTION PERIOD, THE CON7RAC70R SHALL PROVIDE INSTRUCTIONS AND DEMONSTRATIONS FOR THE OWNER'S REPRESENTATIVES ON THE OPERATION AND MAINTENANCE OF ALL EQUIPMENT, AND PROVIDE 3 SETS OF O&M MANUALS. O d M MANUAL SHALL INCLUDE CONTACT INFORMATION FOR CONTRACTOR AND MAJOR EQUIPMENT SUPPLIERS. INCLUDE A COPY OF THE PRODUCT SUBMITTAL DATAFOR ALL MAJOR EQUIPMENT ITEMS WITH THE 0 Iii M DATA. INCLUDE SPACE FOR REDUCED SIZE AS -BUILT DRAWINGS 15 WARRANTY: ALL WORK ANO EQUIPMENT SHALL BE WARRANTED TO BE. FREE FROM DEFECTS AND CAPABLE OF PROVIDING SATISFACTORY OPERATION FOR A PERIOD OF ONE YEAR AFTER FINAL ACCEPTANCE: 16 NEVWtMATERIALS: ALL ITEMS ARE NEW UNLESS SPECIFICALLY NOTED AS ENST'ING 17. COMPLETE SYSTEMS: NOT ALL NECESSARY MATERIALS TO PERFORM T89 WORK REQUiRED ARE SPECIFIED OR SHOWN- CONTRACTOR SHALL, PROVIDE ALL ITEMS NEEDED TO HAVE COMPLETED PROPERLY OPERATING SYSTEMS, ITEMS PROVIDED SHALL BE OF COiyAMERCIAL ANSTITUTiONAL QUALITY, CONSISTENT WiTH THE QUALITY OF RELATED ITEMiS PROVIDED ON THE PROJECT OR CURRENTLY BEING USED IN THE BUILDING. IS OFFSETS AND FITTINGS INCLUDE IN BILI ALL NECESSARY FITTINGS AND OFFSET TO COMPLETELY CONNECT UP ALL SYSTEMS, MAINTAIN CLEAR ACCESS PATHS TO EQUIPMENT, AND COMPLY WiTH ALL PROJECT REQUIREMENTS. OFFSETS ARE REQUIRED TO ROUTE. AROUND BUILDING STRUCTURAL ELEMENTS. ROOF SLOPES, MECHANICAL SYSTEMS, ELECTRICAL SYSTEMS, AND NUMEROUS OTHER ITEMS. DUE TO THE SCHEMATIC NATURE OF THE FLANS $UGH OFFSETS ARE TYPICALLY NOT SHOWN. CONTRACTOR IS RESPONSIBLE TO DETERMINE THE QUANTITY OF OFFSETS AND FITTINGS REQUIRED. AND THE LABOR INVOLVED. NO ADDED PAYMENT OR'EICTRAS' WILL BE GRANTED FOR THE CONTRACTOR'S FAILURE TO CORRECTLY ESTIMATE THE NUMBER OF OFFSETS AND FITTINGS AND LABOR REQUIRED. CONTRACTOR IS ADVISED THAT EQUIPMENT AND CONNECTIONS MAY REQUIRE MORE OFFSETS AND TRANSITIONS 19 CONTRACTOR LAY -OUT: THE CONTRACTOR IS REQUIRED TO DO FURTHER LAYOUT TO FINALIZE THE DESIGN SHOtM+1 ON THE PROJECT DRAWINGS. SUCH MRK INCLUDES FIELD INVESTIGATION OF ALL EXISTING CONDITIONS, LAYOUT SKETCHES TO VERIFY RISES AND ORCIPS IN PIPING AND DUCTWORK, COORDINATiON. OF ELEVATIONS %NITH OTHER TRADES, AND NOTIFYING OTHER TRADES OF ITEMS TO BE RELOCATED. ETC. 20. ALL ITEMS REQUIRING MAINTENANCE SHALL BE ARRANGED TO BE ACCESSIBLE A I B I E GE E TIONS SECTION 02 00 DO - SITEVMRK I. SITE CLEARING: CLEAR SITE AS NEEDED FOR NEW TRENCHING AND PAO INSTALLATION. DISPOSE OF ALL MATERIAL OFF SITE. PROVIDE PROTECTION OF AOJACENTAREA4S FROM DUSTIDIRTINOISEIEROSiON AND OTHERADVERSE AFFECTS DUE TO CONSTRUCTION. REPAIR ALL DISTURBED AREAS TO RE -CONSTRUCTION CONDITION OR BETTER. SECTION 06 10 00- ROUGH CARPENTRY 1. FRAMING AND TREATED LUMBER: DOUG-FIRILARCH NO- 2OR HEM -FIR NO.1 OR BETTER, MINIMUM F=1200 PSI (SINGLE USE). CONFIRM TO WEST COAST LUMBER INSPECTION 8UREAL UB OR WE WOOD (WCUB) PRODUCTS ASSOCIATiflN (VWMtPA). EACH PIECE OF LUMBER SHALL BEAR THE VVCLIS OR ~A GRADE TRADEMARK 2 FRAMING CONNECTORS AND BRIDGING: SHALL BE [.C.B.O. APPROVED AND SHALL BE MANUFACTURED BY SIMPSON OR BOWMAN OR APPROVED EQUAL, FURNISHED COMPLETE WITH ANY SPECIAL NAILS REQUIRED ALL FRAMING CONNECTORS SHALL. BE HOT -DIPPED GALVANIZED. 3. ROUGH HARDWARE' PROVIDE ROUGH HARDWARE OF THE TYPE AND SIZE NECESSARY FOR THE PROJECT REQUIREMENTS. SIZES. TYPES, AND SPACING OF FASTENINGS OF MANUFACTURED BUILDING MATERIALS SHALL SE AS RECOMMENDED BY THE PRODUCT MANUFACTURER UNLESS OTHERWISE INDICATED OR SPECIFIED. 4. PLYWOOD. GROUP 1 OR GROUP 2 SPECIES, C -D GRADE EXPOSURE 1 CONFORMING TO PS 1-83. EACH PIECE SHALL BEAR THE GRACE TRADEMARK OF THE AMERICAN PLYWOOD ASSOCIAT10N. PLYW 000 SHALL HAVE A SPAN RATING CIF 4w4. SECTION 20 0640- MECHANICAL GENERAL i IDENTIF[CAT[ON: ALL EQUIPMENT SHALL 8 I LARALLED WITH A MINIMUM 34N CH HIGH PHENOLIC LABEL CORRESPONDING TO THE SYBOL SHOWN ON THE PLANS. 2 TESTING: ALL PIPING AND SYSTEMS SHALL BE PRESSURE TESTED PER CODE REQUIREMENTS AND TO AT LEAST 1.5 TIMES THE SYSTEMS ALLOWED OPERATING PRESSURE, AS REQUIRED BY CODE, AND IN ACCORDANCE VOTH THE OWNER'S STANDARDS 3. SEISMIC: ALL PIPING, DUCTWORK, AND EQUIPMENT SHALL BE INSTALLED AND BRACED FOR THE SEISMIC CATEGORY FOR THIS PROJECT PER SMACNA "SEISMIC RESTRAINT MANUAL GUIDELINES FOR MECHANICAL SYSTEMS', LATEST EDITION, 4. PROVIE 2 SETS OF SPARE FILTERS FOR ALL UNITS %MTH FILTERS. 5. COMMISSIONING: ALL MECHANICAL SYSTEMS ARE TO BE COMMISSIONED PER CODE REQUIREMENTS THE CONTRACTOR HAS SPECIFIC RESPONSIBILITIES FOR SCHEDULING, COORDINATION, STARTUP, TEST DEVELOPMENT, TESTING AND DOCUMENTATION SECTION 20 05 29 - HANGERS SUPPORTS SLEEVES AND SEALS 1. SEISMIC RESTRAINTS: PROVIDE SEISMIC BRACING FOR EQUIPMENT IN ACCORDANCE VATH -SEISMiC RESTRAINT MANUAL GUIDELINES FOR MECHANICAL SYSTEMS' 2. DUCT sUPPORTS: SHALL BE SPACED ON MAxI?,AOM S FOOT CENTERS EXCEPT WHERE THE DUCT SIZE IS LARGER THAN 24' DIAMETER (OR RECTANGULAR EQUIVALENT, E.G 24X20} HANGERS SHALL $E ON MAXIMUM 6 FOOT CENTERS. SHALL COMPLY WITH SMACNA AND CODE REQUIREMENTS. 3. SECTION 20 05 93 -AIR BALANCING 4. GENERAL: SHALL BE BYA COMPANY SPECIALIZING IN THIS WORK. S. BALANCE: BALANCE SYSTEM TO VALUES SHOWN ON DRAWINGS, PROVIDE WRITTEN REPORT (MINIMUM 3 COPIES) DOCUMENTIN13 UNIT DATA AND ALL 8ALANCING WORK MARK FINAL DAMPER POSITIONS WITH PERMANENT MARKER. 6 CONTRACTOR SHALL COORDINATE AND ASSIST WITH BALANCER TO ALLOW FOR ACCESS TO ALL ITEMS. PROVIDE ADDED BALANCING DAMPERS AND VALVES AS THE ]BALANCER MAY REQUIRE SECTION 200740_ INSULATION 1. DUCTWORK BLANKET FIBERGLASS INSULATION, 0.75 LS PER CUBiC FOOT MINIMUM DENSITY, THERMAL CONDUCTIVITY NO GREATER THAN 0.2S BTU4NlHR-SQ FT -DEGREES F AT 75 DEGREES F WITH FACTORY APPLIED VAPOR PROOF JACKET CONSISTING OF ALUMINUM FOIL COVER WITH OPEN MESH FIBERGLASS REINFORCEMENT, LAMINATED TO UL RATED KRAFT, VAPOR TRANSMISSION RATE SHALL NOT EXCEED 0.45 PERMS 2. DUCT INSULATION INSTALLATION: A. ALL SUPPLY AIR DUCTS SHALL BE INSULATED AND ALL RETURN AIR "{f DUCTS LOCATED OUTSiDE CONDITIONED AREAS SHALL BE INSULATED. B INSULATION THICKNESSES SHALL BE AS FOLLOWS: 1. UNLINED SUPPLY AIR DUCT WITHIN CONDITIONED AREA: 7.0 INCH THICK 2. LINED SUPPLY AIR DUCT WITHIN CONDITIONED AREA: NO INSULATION REQUIRED. 3. UNLINED OR LINED SUPPLY AIR DUCT OUTSIDE CONDITIONED AREA (SUCH AS ABOVE ROOF)- 2 0 INCH THICK. SECTION 23 3100- DUCTWORK SYSTEMS I GENERAL FABRICATE AND INSTALL DUCTWORK IN ACCORDANCE WITH SMACNA DUCT CONSTRUCTION PUBLICATIONS AND ASHRAE HANDBOOKS. MATERIALS AND INSTALL.A71ONS SHALL COMPLY WWiTH NFPA 50A, NFPA 908, AND THE IMG. 2 DUCT SIZES: ALL DUCT SIZES ARE INSIDE CLEAR DIMENSIONS. WHERE INSIDE DUCT LINING IS SHOWN, DUCT 01MENSIONS ARE TO THE; INSIDE FACE OF LiNING 3 DUCT PRESSURE CLASS: A SUPPLY OUCTWIQDRK UPSTREAM OF VAV BOXES: +10' W.G B. SUPPLY DUCTMRKDOVMSTREAM OF VAV BOXES, AND OTHER SUPPLY DUCTWORK +2' WG_ C. EXHAUST AND RETURN DUCTWORK: -2' W.G 4 CONSTRUCT OF GALVANIZED SHEET STEEL. SUITABLE FOR LOCK FORMING WTHOUT FLAKING OR CRACKING, CONFORMING TO ASTM A527. HAVING A ZINC COATING OF U 90 F I G OUNCES TOTAL PER SQUARE FOOT FOR BOTH SiDES OF A SHEET, CORRESPONDING TO COATING DESIGNATION 090 PER ASTM A525. DUCT GAUGE. REINFORCEMENT, JOINTS. SEAMS AND CONNECTIONS SHALL BE AS SHOWN iN SMACNA HVAC DUCT CONSTRUCTION STANDARDS ACCORDING TO THE PRESSURE CLASSIFICATION OF THE SYSTEM AND THE DUCT DIMENSIONS. 5. DUCT LINING: FLEXIBLE, INORGANIC GLASS FIBER MATERIAL, MAXIMUio1 THERMAL CONDUCTIVITY OF 0.26 8TU-INCHfHR-SQ.FT.-DEGREES FAT 75 DEGREES F, COATED TQ PREVENT EROSION, AND CONFORMING TO SMACNA DUCT LINER APPLICATION STANDARD. LINING SHALL BE 1 -INCH THICK ADHESIVE, FASTENERS, AND INSTALLATION SHALL BE IN ACCORDANCE WITH SMACNA APPLICABLE STANDARDS S. EXHAUST DUCTS. ROUND EXHAUST DUCT MAY HAVE SPIRAL LOCKSTREAM OR BUTT -WELDED LONGITUDINAL SEAM CONSTRUCTION. CONNECTIONS SHALL BE WELDED: USING SLiP-TYPE OR FLANGED CONNECTIONS FOR DUCT SIZES LESS THAN 36 DIAMETER, AND FLANGED CONNECTIONS FOR LARGER DUCT SIZES. WELD SPACING AT FLANGES SHALL MATCH SMACNA REiNFORCEMENT TABLE REQUIREMENTS. BUT IN NO CASE BE LESS THAN V LONG ON 10` CENTERS. FLANGE SIZES SHALL BE PER SMACNA REQUIREMENTS. FITTINGS SHALL BE FULLY WELDED: WiTH ELBOWS HAVING 1-112' DUCT DIAMETER RADIUS 7. SUPPLY DUCTS: SHALL BE PER SMACNA STANDARDS FOR PRESSURE CLASS CITED. ROUND LINED DUCT SHALL CONSIST OF i -INCH ACOUSTIC INSULATION IN-BETWEEN A PERFORATED INTERIOR DUCT LiNER AND SOLID MAINTAIN POSITIVE CONCENTRICITY OF LINER WITH DUCT. INSULATION SHALL HAVE A M (MUM THERMAL CONOUCTIVITY OF 0.2$ BTU-iNCHfHR-SQ. FT. -DEGREES F AT 75 DEGREES F. UNITED-MCGILL UNITED SHEET METAL'ACOUSTt-K27 OR APPROVED. 8. MANUAL DAMPERS: SHALL BE FABRICATED OF GALVANIZED STEEL, TWO GAUGES HEAVIER THAN DUCT IN WHICH iNSTALLF0_ REGULATOR SETS SHALL HAVE QUADRANT DiAL REGULATOR WITH LOCKING NUT, SQUARE END BEARING ONE SIDE, AND SPRING OR ROUND END BEARING OTHER SIDE. 8. ACCESS DOORS: DOUBLE WALL, MINIMUM 14 GAUGE, HINGED iDR CAMLOCK ACCESS DOOR. DOORS IN INSULATED DUCT SHALL BE INSULATED TYPE. 10. DUCT INSTALLATION: INSTALL ALL DUCTWVQRK IN SIZES AND LOCATIONS AS SHOVW ON THE DRAWINGS. COMPLETE WITH ALL ACCESSORIES AND CONNECTIONS TO PROVIDE COMPLETE AND OPERABLE HEATING. VENTILATING, AIR COND)TIONING, AND EXHAUST SYSTEMS. DUCT SHALL BE INSTALLED LEVEL AND IN NEAT LINES WiTH THE BUILDING CONSTRUCTION. ALL DUCTS ARE TO BE INSTALLED CONCEALED UNLESS INDICATED OTHERWISE 11. DUCT SEALING: SEAL ALL JOINTS iN ACCORDANCE WITH SEAL CLASSIFICATION AS SHOWN IN SMACNAHVAC DUCT CONSTRUCTION STANDARDS. IN ADDITION TO APPLYING, SEALANT TO JOINTS IN ACCORDANCE WITH THE SMACNA REQUIREMENTS, ALL JOINTS AND SEAMS SHALL BE TAPED OVER WITH MINIMUM 34NCHWOE DUCT TAPE SUCH TAPE IS NOT REQUIRED ON EXPOSEO DUCTS, BUT ALL JOINT CORNERS SHALL HAVE ADHESIVE APPLIED. 12. FLEXIBLE DUCT: FACTORY INSULATED FULLY UNED FLEXIBLE DUCT. DUCT SHALL HAVE FULL INTERNAL LINER, REINFORCED WMTH ZINC COATED STEEL HELIX, LINER BONDED TO 1 -INCH THICK FIBERGLASS INSULATION, WITH MAXIMUM CONDUCTIVITY OF 0.26 5TU-INC:H1HRtiSQ FT. -DEGREE F AT 75 DEGREES AND HAVING, A POLYETHYLENE OUTER VAPOR BARRIER. PROVIDE ENDS WITH COMPRESSION CLAMPS FOR POSITiVE CONNECTION TO OVAL OR ROUND FITTINGS, SHALL COMPLY WITH NFPA 90A AND 908 AND SHALL. BE UL LISTED AND LABELED AS A CLASS 1 CONNECTOR PER UL STANDARD 161 FLEXIBLE DUCT SHALL ONLY BE USED AT DIFFUSER CONNECTION, AND SHALL NOT FiXCEED 2 FEET iN LENGTH, IN STRAIGHT RUNS ONLY (UNLESS SPECIFICALLY SHOWN OTHERWISE ON GLANS). DUCT PRESSURE RATINGS SHALL MATCH PRESSURE CLASS OF DUCT SYSTEM INSTALLER ON SECTION 25 0500 - CONTROLS 1. GENERAL: CONTROLS PROVIDER SHALL BE SIEMENS REMOVE EXISTING CONTROLS FROM DEMOLISHED UNIT. PROVIDE NEW CONTROLS FOR NEW UNIT, SAME CONTROL SEQUENCE AS EXISTING. PROVIDE ALL DOCUMENTATION OF START-UP INCLUDING POINT TO POiNT CHECKOUT SHEETS, UPDATED SEQUENCE OF OPERATION, AND UPDATED AS -BUILT DRAWINGS. SECTION 26 0540 - ELECTRICAL 1 GENERAL: ALL ELECTRICAL WORK SHALL BP PERFORMED BY WORKERS SKILLED IN THE ELECTRICAL TRADES, AND SHALL COMPLY WITH NEC AND LOCAL CODES. NOT ALL REQUIRED MATERIALS ARE SPECIFIED HEREIN OR NOTED ON THE PLANS, BUT ALL NEEDED ITEMS SHALL BE PROVIDED TO HAVE COMPLETE AND FUNCTIONING MEDICAL GAS ALARM SYSTEMS, POWER SERVICE TO TANK PAD, AND CYLINDER STORAGE ROOM LIGHTING. 2 RACEWAY: SHALL BE GALVANIZED RIGID STEEL (GRS) OR GALVANIZED FLEXIBLE STi F_L TYPE. SHALL BE INSTALLER CONCF-ALE0 EXCEPT WHERE SPECIFICALLY NOTEDAS EXPOSED RACEWAYS INSTALLED AS DIRECT BURY SHALL HAVE 15 MIL PVC COATING 3. COPPER, 600 VOLT, TYPE THW, THMI THHN OR XH14W1 WIRE MAYBE UTILIZED AT CONTRACTOR OPTION, SUBJECT TO CODE REQUIREMENTS. MINIMUM WIRE SIZE IS 12 AWG FOR POWER AND LIGHTING CIRCUITS 4, JUNCTION BOXES: SHALL BE CONSTRUCTED OF ZINC COATED STEEL, FOUR INCH SIZE MINIMUM, TYPE TO SUIT APPLICATION. S. DISCONNECTS: SHALL BE HEAVY DUTY, SINGLE THROW, LOCKABLE TYPE, HAVING DOOR INTERLOCK (TO PREVENT OPENING WHEN ENERGIZED), ENCLOSURE TO SUITE ENVIRONMENT REVIEWED FOR CODE COMPLIANCE APPROVED SEP 2 2 2016 City of Tukwila BUILDING DIVISION WSW Iigoomp i zo 2 m Rl a 11 9 F-CEIVED CIT OF TUKWILA Ptip 10ENT2 2016 M 1T ER 10 u I t OAS HEAT/ELECTRIC COOLING UNIT SCHEDULE SPECIFIED COOLING CAP.- HEATING CAP " _ SUPPLY FAN COMPRESSOR GOND. FAN COMB. FAN POWER EXHAUST FAN FILTERS MAS` MIN UNIT ELECTRICAL cl e SYMBOL MANUFACTURER AND NUMBER AREA SERVED �. __. - ----- ------.-• ---- -�� � to WEIGHT OAREMARKS.SERIES . CL O '2�pl -------- ---- j I MQH MBH EFF MSH f UE CFM ESP HP QTY RLA (E,A) O -r^ FLA (EA) PTY HP IEA) CFM ESP HP TYPE MiN SIZE LBS MCA MFS VOLTSiPH HVAC -i YORIVJCI V54AS54 MAIN OFFICE 475 8 475 8 EE'R 533 _ 426 4 80% 16,0(?0 2.51, 25 a 16.7 4 2 9 1 0.6 - 0.5" 7.5 } 11 SF 6,450 3300 132 150 48013 SEE NOTES BELOW ai 1.; I I SIGNE6 �4�43-2618 r= { L1J .�1 f Cil l =4 rz .i, 2Z it CI ZW 7'G d uj W(f) 1 W . c1 MERV 11 Q I �.r y m''.' ' COOLING CAPACITY IS AR.1 RATING: AT 80" F DB; 67° F WB INDOOR NOTES 1 PROVIDE ALL. UNITS WITH 0.100% LDA ECONOMIZER. DISCONNECT CUBES. 4 WEIGHT INCLUDES UNIT CURES 8 ACCESSORIES 8 SHALL NOT SEE EXCEEDED. COIL EAT, 95'F OUTDOOR COiL EAT, AND ARI NOMINAL CFM RELIEF AIR CAPABILITY, HINGED ACCESS DOORS, 9 SMOKE DETECTOR. 5. WITH CUSTOM OFFSET CURB ADAPTOR. 2 ALL UNITS SHALL USE R4 10A OR R407C REFRIGERANT (UNC}). RATED IN ACCORDANCE WITH ANSI IIID DOE STANDARDS 5. WITH DDC SYSTEM CONTROL INTERFACE, AND RA, SA, AND OA TEMPERATURE SENSORS 3 UNIT CAPACITIES SHALL BE WITHIN 5% OF THOSE SCHEDULED. 7. SINGLE POINT POWER WITH DISCONNECT AND CONVENIENCE OUTLET. mr ROJ E OT PSE C I F ICIAATlOr4b 1. SECTION 23 1123 -GAS PIPING 2 STEEL PIPE FITTINGS. A THREADED FiTTLNGS• MALLEABLE IRON PER ASME B18 3- CAST IRON PER ASME 816.4. 3 GAS PIPING: SCHEDULE 40 STEEL PIPING {COMPLYING VMTH ASME A53} Wr~dTH THREADED CLASS 125 FITTINGS. 4. ZUL LISTED FOR GAS SERVICE. BRONZE TWO-PIECE BLOWOUT PROOF STEM, FULL PORT. NIBCO T -685 -70 -UL. 5. RATED AT MINIMUM 125 PSIG AT 200 DEGREES F; PROVIDE DIELECTRIC UNIONS WHERE DISSIMILAR METALS JOIN. PROVIDE UNIONS AT CONNECTIONS TO ALL EQUIPMENT 6. INSTALLATION: FOLLOW ESTABLISHED PROFESSIONAL PRACTICES FOR JOINING OF PIPING AND STT AS TO SUIT THE SYSTEM PRESSURES AND TEMPERATURES INVOLVED. 7. SECTION 23 81 53 - HVAC UNITS 8. HVAC UNITS ROOFTOP PACKAGED GAS HEAT ELECTERiC COOL ROOFTOP UNIT$ WITH AS A MINIMUM SCHEDULES CAPACITY. SEE SCHEDULE FOR ACCESSORIES MANUFACTURER AND MODELAS SCHEDULED. 9. PROVIDE WiTH 0-100% OA ECONOMIZER AND CUSTOM ROOF ADAPTOR CURB ENERMY COBE. - HVAC 1 LOAD CALCULATIONS HAVE BEEN PERFORMED IN ACCORDANCE WITH WSEC C4032.1..OR EQUIPMENT IS SELECTED AT SAME CAPACITY AS THE UNIT BEING REPLACED. 2 EQUIPMENT HAS BEEN SELECTSI3 PER WSEC 0403.2.2 3 VENTILATION AND THE ABILITY TO REDUCE OUTSIDE AIR TO IMG MINIMUM$ SHALL BE PROViDED PER WSEC 0403 2 5. 4 MOTORS i HP AND LARGER SHALL BE ENERGY EFFICIENT TYPE PER VVSEC C403.2.13: MOTORS 1112 HP TO 1 HP SHALL BE EiCM *TYPE OR MEET L41NIMUM EFFICIENCY REQUIREMENTS PER WSEC C403.2.10.3. S. TEMPERATURE CONTROL SYSTEM SHALL HAVE A MINIMUM DEAD BAND OF 5 DEGREES AS REQUIRED BY WSEC 0403.2.4.2. 6. HVAC SYSTEMS SHALL BE EQUIPPED VIATH AUTOMATIC CONTROLS CAPABLE OF PROVIDING NIGHT SETBACK. SEVEN DIFFERENT DAILY SCHEDULES, AND OPTIMUM START PER THE REQUIREMENTS OF WNSEC C403.2 4.3 7 OUTSIDE AIR INTAKES, EXHAUST OUTLETS, AND RELIEF OUTLETS SHALL BE PROVIDEDWMTH DAMPERS THAT COMPLY WITH WSEC C403.2.4.4. DAMPER SHALL AUTOMATLCALLY CLOSE VVI-IEN SYSTEM OR SPACES SERVED ARE NOT IN USE OR DURING WARM-UP. COOL4)OWN, AND SETBACK DAMPER MAXIMUM LEAKAGE RATE SHALL NOT EXCEED MAXiMUM ALLOWED BYVVSf:C 0402.4.52 a COMBUSTION HEATING EQUIPMENT WITH A CAPACITY OVER 225 MBH SHALL HAVE MODULATING OR STAGED COMBUSTION CONTROL PER WSEC C+403.Z4.6. 9. FAN SYSTEMS SERVING A ZONE OR MULTIPLE ZONES WViTHOUT SEPARATING WALLS WMTH TOTAL AIRFLOVV OVER 10,E: W CFM SHALL REDUCE AIRFLOWWi BASED ON SPAC E HEATING AND COOLING DEMAND PER WSEC 0403.2.122 10. ALL DUCTIM(3RK SHALL BE CONSTRUCTED AND SEALED IN ACCORDANCE VATH IMC, MEC C402 AND LSC REQUIREMENTS PER MEC C403.2.7. 11 DUCTS AND PLENUMS DESIGNED TO OPERATE AT A PRESSURE ABOVE 3' W.C. SHALL BE LEAK TESTED PER WNSSC 0403.2 7.3.3. DOCUMENT AND SUBMIT TEST RESULTS TO THE AHJ AS REQUIRED 12. DUCTWORK SHALL BE INSULATED TO THE APPROPRIATE R -VALUE AS REQUIRED BYyti EC 0403.2 7. 13 PROVIDE HIGH LIMiT SHUT-OFF CONTROL OF ECONOiySIZER COOLING PER TABLE C403.3.1.1.3(2) 14 ECONOMIZER DAMPERS SHALL BE CAPABLE OF BEING SEQUENCED WITH MECHANICAL COOLING EQUIPMENT. ECONOMIZERS ON SYSTEMS WViTH COOLING CAPACITY GREATER THAN 65 MBH SHALL BE CAPABLE OF PROVIDING PARTIAL COOLING PER MEC 0403.3.1.1.2 15. ECONOMIZER CONTROLS SHALL BE SUCH THAT ECONOMIZER OPERATION DOES NOT INCREASE BUILDING HEATING ENERGY DURING NORMAL OPERATIONS PER WSEC C403,4.1.4, AND SHALL BE INTEGRATED WITH MECHANICAL COOLING SYSTEM AND BE CAPABLE OF PROVIDING PARTIAL COOLING PER WSEC 0403.4.1.3 16. FORVAV SYSTEMS WITH ODD, PROVIDE STATIC PRESSURE RESET PER VWSEC 0403.4.2.2 17. SUPPLY ALR SYSTEMS SERVING MULTIPLE ZONES SHALL BE VAV TYPE DESIGNED AND CAPABLE OF $EING CONTROLLED TO REDUCE PRIMARY AiR SUPPLY TO EACH ZONE TO A MAXIMUM FLOW RATE AS ALLOWED BY WSEC 0403 4 5. IS. HVAC SYSTEMS NTH MULTIPLE ZONES SHALL REQUIRE TEMPERATURE RESET CONTROLS MICH AUTOMATICALLY RESET SUPPLY AIR TEMPERATURES PER WSEC 0403.4.5.4. 19. COOLING SYSTEMS SHALL. NOT USE HOT GAS BYPASS OR OTHER EVAPORATOR PRESSURE CONTROL SYSTEMS UNLESS THERE ARE MULTIPLE STEPS OF UNLOADING, HOT GAS BYPASS CAPACITY SHALL BE LIMITED PER TABLE 0403.4.7. DOES NOT APPLY TO UNITARY PACKAGED SYSTEMS 90 MBH OR SMALLER 20. AIR SHALL BE BALANCED AS REQUIRED IN SECTION 0408 2.21 AND C408.2.2 2 OF THE WSEC 21. PROVIDE COMMISSIONING PLAN 8 REPORT REQUIREMENTS FOR PRELIMINARY MID FiNAL COMMISSION048 PER SECTION C408.1. PROVIDE SECiLIENCE OF OPERATIONS AND TEST PROCEi3URES PER SECTION C•4U6.1.2 AND SUBMIT COMPLIANCE CHECKLIST PER SECTION 0108.1 3 4 OF THE WSEC TO THE BUILDING OFFICiAL UPON SUBSTANTIAL COMPLETION. 22. THESE'ENERGY CODE NOTES' ARE LiSTED TO SATISFY THE BUILDING DEPARTMENTS REQUIREMENT THAT CERTAIN INFORMATION BE PLACED ON THE PIANS, BUT DO NOT DIMINISH THE FULL PROJECT REQUIREMENTS PROVIDE ITEMS IN EXCESS OF CODE WHERE NOTED ON DRAWINGS AND IN SPECIFICATIONS. FOR OTHER ADDED REQUIREMENTS, SEE SPECIFICATIONS. SECTION 010000 -GENERAL 1. CODE CCMPLIANCE- ALL WORK SHALL COMPLY WITH ALL LOCAL CODES AND ORDINANCES 2 DRAW NGS. DRAW NGS ARE DIAGRAMMATIC AND SHOWN THE GENERAL ARRANGEMENT OF THE CONSTRUCTION, AND THEREFORE DO NOT SHOW ALL NECESSARY OFFSETS, FITTINGS, ALTERATIONS TO EXISTING ITEMS, AND ACCESSORIES WHICH ARE REQUIRED TO FORM COMPLETE AND OPERABLE SYSTEMS. 3 FIELD VERIFICATION: THE CONTRACTOR SHALL BE RESPONSIBLE FOR CHECKING FIELD CONDITIONS AND VERIFYING ALL MEASUREMENTS AND RELATIONSHIPS INDICATED ON THE DRAWINGS BEFORE SUBMITTING BIDS AND AGAIN BEFORE PROCEEDING WITH THE WORK 4. NOTiFY THE ARCH ITECT1ENGINEER OF ANY CiISCREPANCIES OR CONFLICTS BEFORE PROCEEDING WITH ANY MRK OR THE PURCHASING OF ANY MATERIALS FOR THE ARENS) OF CONFLICT UNTIL REQUESTING AND OBTAINING VVR ITTEN INSTRUCTIONS FROM THE ARCHITECTIENGINEER ON HOWTO PROCEED. WHERE CONFLICTS OCCUR, THE MOST EXPENSIVE AND STRINGENT REQUIREMENT(AS JUDGED BYTHE ARCHiTEICTIENGiNEER) SHALL PREVAIL. ANY WORKDONE AFTER DiSC,0VERY OF SUCH DISCREPANCIES OR CONFLICTS AND PRIOR TO OBTAINING THE ARCHITECTIENGINEER'S INSTRUCTIONS ON HOW TO PROCEED SHALL BE DONE AT THE CONTRACTOR'S EXPENSE. 5 DRAVWiNGS AND SPECIFICATIONS. DRAWINGS AND SPECIFICATIONS ARE COMPLEMENTARY AND WHAT IS CALLED FOR IN EITHER IS BINDING AS IF CALLED FOR IN BOTH. THE DRAWINGS ARE DIAGRAMMATIC AND SHOWTHe OENeRAL ARRANGEMENT OF THE CONSTRUCTION AND THEREFORE DO NOT SHOWALL- OFFSETS, FITTINGS AND ACCESSORIES MICH ARE REQUIRED TO FORM A COMPLETE AND OPERATING INSTALLATION. MECHANICAL WORK IS SHOWN ON MULTIPLE DRAWNNOS AND IS NOT LIMITED TO A PARTICULAR SET OF SHEETS, OR SHEETS PREFACED VOTH A PARTICULAR LETTER. 6. PERMITS AND FEES: THE CONTRACTOR SHALL OBTAIN AND PAY FOR ALL PERMITS. LICENSES, FEES AND INSPECTIONS AS REQUIRED 6Y THE GOVERNING CODES AND AS SPECIFIED HEREIN. 7. SUBMITTALS: CONTRACTOR SHALL SUBMIT SHOP DRAWW INGS FOR ALL PRODUCTS PROPOSED TO BE USED ON THIS PROJECT FOR OWNER REVIIEW- PRODUCTS SHALL NOT BE USED UNTIL APPROVED BY THE OVWMER OR HIS REPRESENTATIVE. SUBMIT 3 COPIES PLUS ANYADVITiONALQUANTITIES THE CONTRACTOR NEEDS (3 COPIES %MLL BE RETAINED BY THE OWNER). 6 RECORD DRAWINGS: THE CONTRACTOR SHALL MAINTAIN A SET OF CONTRACT PLANS AT THE PROJECT SITE UPON WHICH ALL CHANGES FROM THE AS -BID PLANS ARE NOTED. AT THE. COMPLETION OF THE PROJECT, THE CONTRACTOR SHALL DELIVER TO THE OWNER ONE COMPLETE SET OF THESE RECORD DRAWINGS. 9. PROTECTION: CONTRACTOR IS RESPONSIBLE FOR PROTECTION OF ALL MATERIAL, FOUIPMENTANDAPPARATUS PROVIDED UNDER THIS SECTION FROM DAMAGE. WATER, CORROSION, FREEZING AND DUST, BOTH IN STORAGE AND WHEN INSTALLEO, UNTIL FINAL PROJECT ACCEPTANCE 10 COORDINATION THE CONTRACTOR SHALL COORDINATE ALL CONSTRUCTION ACTIVITIES WITH THE OWNER AND COOPERATE FULLY SO AS TO MINIMIZE CONFLICTSAND TO ALLOW FULL OWNER USAGE (UNLESS INDICATED OTHERWIWiSE) OF ALL AREAS DURING CONSTRUCTION 11. CUTTING AND PATCHING: SHALL BE DONE BY SKILLED LA13OR EXPERIENCED IN PROVIDING OPENINGS AND PATCHING OF THE MATERIALS INVOLVED. AREAS SHALL BE PATCHEDAND RESTORED TO AFiNISHEO CONDITION, EQUAL TO ADJACENT FINAL FINISHED AREAS THAT HAVE NOT BEEN CUT 12. PAINTING: SHALL BE PROVIDEO VMERE INDICATED, BY SKILLED PAINTERS IN CONFORMANCE WITH STANDARD PROFESSIONAL PRACTICE INCLUDING CLEANING AND PRIMING OF MATERIALS TO BE PAINTED. COLORS SHALL BE SELECTED BY THE OWNER 13. FINAL INSPECTION: PRIOR TO ACCEPTANCE OF THEWORK THE CONTRACTOR SHALL PUT ALL SYSTEMS INTOOPERATION FORA PRRIOD OF NOT LESS THAN S WORKING DAYS 60 THAT THEY MAY BE INSPECTED BY THE OVWER. 14 INSTRUCTION! O S M MANUALS: DURING THE FINAL iNSPECTION PERIOD, THE CON7RAC70R SHALL PROVIDE INSTRUCTIONS AND DEMONSTRATIONS FOR THE OWNER'S REPRESENTATIVES ON THE OPERATION AND MAINTENANCE OF ALL EQUIPMENT, AND PROVIDE 3 SETS OF O&M MANUALS. O d M MANUAL SHALL INCLUDE CONTACT INFORMATION FOR CONTRACTOR AND MAJOR EQUIPMENT SUPPLIERS. INCLUDE A COPY OF THE PRODUCT SUBMITTAL DATAFOR ALL MAJOR EQUIPMENT ITEMS WITH THE 0 Iii M DATA. INCLUDE SPACE FOR REDUCED SIZE AS -BUILT DRAWINGS 15 WARRANTY: ALL WORK ANO EQUIPMENT SHALL BE WARRANTED TO BE. FREE FROM DEFECTS AND CAPABLE OF PROVIDING SATISFACTORY OPERATION FOR A PERIOD OF ONE YEAR AFTER FINAL ACCEPTANCE: 16 NEVWtMATERIALS: ALL ITEMS ARE NEW UNLESS SPECIFICALLY NOTED AS ENST'ING 17. COMPLETE SYSTEMS: NOT ALL NECESSARY MATERIALS TO PERFORM T89 WORK REQUiRED ARE SPECIFIED OR SHOWN- CONTRACTOR SHALL, PROVIDE ALL ITEMS NEEDED TO HAVE COMPLETED PROPERLY OPERATING SYSTEMS, ITEMS PROVIDED SHALL BE OF COiyAMERCIAL ANSTITUTiONAL QUALITY, CONSISTENT WiTH THE QUALITY OF RELATED ITEMiS PROVIDED ON THE PROJECT OR CURRENTLY BEING USED IN THE BUILDING. IS OFFSETS AND FITTINGS INCLUDE IN BILI ALL NECESSARY FITTINGS AND OFFSET TO COMPLETELY CONNECT UP ALL SYSTEMS, MAINTAIN CLEAR ACCESS PATHS TO EQUIPMENT, AND COMPLY WiTH ALL PROJECT REQUIREMENTS. OFFSETS ARE REQUIRED TO ROUTE. AROUND BUILDING STRUCTURAL ELEMENTS. ROOF SLOPES, MECHANICAL SYSTEMS, ELECTRICAL SYSTEMS, AND NUMEROUS OTHER ITEMS. DUE TO THE SCHEMATIC NATURE OF THE FLANS $UGH OFFSETS ARE TYPICALLY NOT SHOWN. CONTRACTOR IS RESPONSIBLE TO DETERMINE THE QUANTITY OF OFFSETS AND FITTINGS REQUIRED. AND THE LABOR INVOLVED. NO ADDED PAYMENT OR'EICTRAS' WILL BE GRANTED FOR THE CONTRACTOR'S FAILURE TO CORRECTLY ESTIMATE THE NUMBER OF OFFSETS AND FITTINGS AND LABOR REQUIRED. CONTRACTOR IS ADVISED THAT EQUIPMENT AND CONNECTIONS MAY REQUIRE MORE OFFSETS AND TRANSITIONS 19 CONTRACTOR LAY -OUT: THE CONTRACTOR IS REQUIRED TO DO FURTHER LAYOUT TO FINALIZE THE DESIGN SHOtM+1 ON THE PROJECT DRAWINGS. SUCH MRK INCLUDES FIELD INVESTIGATION OF ALL EXISTING CONDITIONS, LAYOUT SKETCHES TO VERIFY RISES AND ORCIPS IN PIPING AND DUCTWORK, COORDINATiON. OF ELEVATIONS %NITH OTHER TRADES, AND NOTIFYING OTHER TRADES OF ITEMS TO BE RELOCATED. ETC. 20. ALL ITEMS REQUIRING MAINTENANCE SHALL BE ARRANGED TO BE ACCESSIBLE A I B I E GE E TIONS SECTION 02 00 DO - SITEVMRK I. SITE CLEARING: CLEAR SITE AS NEEDED FOR NEW TRENCHING AND PAO INSTALLATION. DISPOSE OF ALL MATERIAL OFF SITE. PROVIDE PROTECTION OF AOJACENTAREA4S FROM DUSTIDIRTINOISEIEROSiON AND OTHERADVERSE AFFECTS DUE TO CONSTRUCTION. REPAIR ALL DISTURBED AREAS TO RE -CONSTRUCTION CONDITION OR BETTER. SECTION 06 10 00- ROUGH CARPENTRY 1. FRAMING AND TREATED LUMBER: DOUG-FIRILARCH NO- 2OR HEM -FIR NO.1 OR BETTER, MINIMUM F=1200 PSI (SINGLE USE). CONFIRM TO WEST COAST LUMBER INSPECTION 8UREAL UB OR WE WOOD (WCUB) PRODUCTS ASSOCIATiflN (VWMtPA). EACH PIECE OF LUMBER SHALL BEAR THE VVCLIS OR ~A GRADE TRADEMARK 2 FRAMING CONNECTORS AND BRIDGING: SHALL BE [.C.B.O. APPROVED AND SHALL BE MANUFACTURED BY SIMPSON OR BOWMAN OR APPROVED EQUAL, FURNISHED COMPLETE WITH ANY SPECIAL NAILS REQUIRED ALL FRAMING CONNECTORS SHALL. BE HOT -DIPPED GALVANIZED. 3. ROUGH HARDWARE' PROVIDE ROUGH HARDWARE OF THE TYPE AND SIZE NECESSARY FOR THE PROJECT REQUIREMENTS. SIZES. TYPES, AND SPACING OF FASTENINGS OF MANUFACTURED BUILDING MATERIALS SHALL SE AS RECOMMENDED BY THE PRODUCT MANUFACTURER UNLESS OTHERWISE INDICATED OR SPECIFIED. 4. PLYWOOD. GROUP 1 OR GROUP 2 SPECIES, C -D GRADE EXPOSURE 1 CONFORMING TO PS 1-83. EACH PIECE SHALL BEAR THE GRACE TRADEMARK OF THE AMERICAN PLYWOOD ASSOCIAT10N. PLYW 000 SHALL HAVE A SPAN RATING CIF 4w4. SECTION 20 0640- MECHANICAL GENERAL i IDENTIF[CAT[ON: ALL EQUIPMENT SHALL 8 I LARALLED WITH A MINIMUM 34N CH HIGH PHENOLIC LABEL CORRESPONDING TO THE SYBOL SHOWN ON THE PLANS. 2 TESTING: ALL PIPING AND SYSTEMS SHALL BE PRESSURE TESTED PER CODE REQUIREMENTS AND TO AT LEAST 1.5 TIMES THE SYSTEMS ALLOWED OPERATING PRESSURE, AS REQUIRED BY CODE, AND IN ACCORDANCE VOTH THE OWNER'S STANDARDS 3. SEISMIC: ALL PIPING, DUCTWORK, AND EQUIPMENT SHALL BE INSTALLED AND BRACED FOR THE SEISMIC CATEGORY FOR THIS PROJECT PER SMACNA "SEISMIC RESTRAINT MANUAL GUIDELINES FOR MECHANICAL SYSTEMS', LATEST EDITION, 4. PROVIE 2 SETS OF SPARE FILTERS FOR ALL UNITS %MTH FILTERS. 5. COMMISSIONING: ALL MECHANICAL SYSTEMS ARE TO BE COMMISSIONED PER CODE REQUIREMENTS THE CONTRACTOR HAS SPECIFIC RESPONSIBILITIES FOR SCHEDULING, COORDINATION, STARTUP, TEST DEVELOPMENT, TESTING AND DOCUMENTATION SECTION 20 05 29 - HANGERS SUPPORTS SLEEVES AND SEALS 1. SEISMIC RESTRAINTS: PROVIDE SEISMIC BRACING FOR EQUIPMENT IN ACCORDANCE VATH -SEISMiC RESTRAINT MANUAL GUIDELINES FOR MECHANICAL SYSTEMS' 2. DUCT sUPPORTS: SHALL BE SPACED ON MAxI?,AOM S FOOT CENTERS EXCEPT WHERE THE DUCT SIZE IS LARGER THAN 24' DIAMETER (OR RECTANGULAR EQUIVALENT, E.G 24X20} HANGERS SHALL $E ON MAXIMUM 6 FOOT CENTERS. SHALL COMPLY WITH SMACNA AND CODE REQUIREMENTS. 3. SECTION 20 05 93 -AIR BALANCING 4. GENERAL: SHALL BE BYA COMPANY SPECIALIZING IN THIS WORK. S. BALANCE: BALANCE SYSTEM TO VALUES SHOWN ON DRAWINGS, PROVIDE WRITTEN REPORT (MINIMUM 3 COPIES) DOCUMENTIN13 UNIT DATA AND ALL 8ALANCING WORK MARK FINAL DAMPER POSITIONS WITH PERMANENT MARKER. 6 CONTRACTOR SHALL COORDINATE AND ASSIST WITH BALANCER TO ALLOW FOR ACCESS TO ALL ITEMS. PROVIDE ADDED BALANCING DAMPERS AND VALVES AS THE ]BALANCER MAY REQUIRE SECTION 200740_ INSULATION 1. DUCTWORK BLANKET FIBERGLASS INSULATION, 0.75 LS PER CUBiC FOOT MINIMUM DENSITY, THERMAL CONDUCTIVITY NO GREATER THAN 0.2S BTU4NlHR-SQ FT -DEGREES F AT 75 DEGREES F WITH FACTORY APPLIED VAPOR PROOF JACKET CONSISTING OF ALUMINUM FOIL COVER WITH OPEN MESH FIBERGLASS REINFORCEMENT, LAMINATED TO UL RATED KRAFT, VAPOR TRANSMISSION RATE SHALL NOT EXCEED 0.45 PERMS 2. DUCT INSULATION INSTALLATION: A. ALL SUPPLY AIR DUCTS SHALL BE INSULATED AND ALL RETURN AIR "{f DUCTS LOCATED OUTSiDE CONDITIONED AREAS SHALL BE INSULATED. B INSULATION THICKNESSES SHALL BE AS FOLLOWS: 1. UNLINED SUPPLY AIR DUCT WITHIN CONDITIONED AREA: 7.0 INCH THICK 2. LINED SUPPLY AIR DUCT WITHIN CONDITIONED AREA: NO INSULATION REQUIRED. 3. UNLINED OR LINED SUPPLY AIR DUCT OUTSIDE CONDITIONED AREA (SUCH AS ABOVE ROOF)- 2 0 INCH THICK. SECTION 23 3100- DUCTWORK SYSTEMS I GENERAL FABRICATE AND INSTALL DUCTWORK IN ACCORDANCE WITH SMACNA DUCT CONSTRUCTION PUBLICATIONS AND ASHRAE HANDBOOKS. MATERIALS AND INSTALL.A71ONS SHALL COMPLY WWiTH NFPA 50A, NFPA 908, AND THE IMG. 2 DUCT SIZES: ALL DUCT SIZES ARE INSIDE CLEAR DIMENSIONS. WHERE INSIDE DUCT LINING IS SHOWN, DUCT 01MENSIONS ARE TO THE; INSIDE FACE OF LiNING 3 DUCT PRESSURE CLASS: A SUPPLY OUCTWIQDRK UPSTREAM OF VAV BOXES: +10' W.G B. SUPPLY DUCTMRKDOVMSTREAM OF VAV BOXES, AND OTHER SUPPLY DUCTWORK +2' WG_ C. EXHAUST AND RETURN DUCTWORK: -2' W.G 4 CONSTRUCT OF GALVANIZED SHEET STEEL. SUITABLE FOR LOCK FORMING WTHOUT FLAKING OR CRACKING, CONFORMING TO ASTM A527. HAVING A ZINC COATING OF U 90 F I G OUNCES TOTAL PER SQUARE FOOT FOR BOTH SiDES OF A SHEET, CORRESPONDING TO COATING DESIGNATION 090 PER ASTM A525. DUCT GAUGE. REINFORCEMENT, JOINTS. SEAMS AND CONNECTIONS SHALL BE AS SHOWN iN SMACNA HVAC DUCT CONSTRUCTION STANDARDS ACCORDING TO THE PRESSURE CLASSIFICATION OF THE SYSTEM AND THE DUCT DIMENSIONS. 5. DUCT LINING: FLEXIBLE, INORGANIC GLASS FIBER MATERIAL, MAXIMUio1 THERMAL CONDUCTIVITY OF 0.26 8TU-INCHfHR-SQ.FT.-DEGREES FAT 75 DEGREES F, COATED TQ PREVENT EROSION, AND CONFORMING TO SMACNA DUCT LINER APPLICATION STANDARD. LINING SHALL BE 1 -INCH THICK ADHESIVE, FASTENERS, AND INSTALLATION SHALL BE IN ACCORDANCE WITH SMACNA APPLICABLE STANDARDS S. EXHAUST DUCTS. ROUND EXHAUST DUCT MAY HAVE SPIRAL LOCKSTREAM OR BUTT -WELDED LONGITUDINAL SEAM CONSTRUCTION. CONNECTIONS SHALL BE WELDED: USING SLiP-TYPE OR FLANGED CONNECTIONS FOR DUCT SIZES LESS THAN 36 DIAMETER, AND FLANGED CONNECTIONS FOR LARGER DUCT SIZES. WELD SPACING AT FLANGES SHALL MATCH SMACNA REiNFORCEMENT TABLE REQUIREMENTS. BUT IN NO CASE BE LESS THAN V LONG ON 10` CENTERS. FLANGE SIZES SHALL BE PER SMACNA REQUIREMENTS. FITTINGS SHALL BE FULLY WELDED: WiTH ELBOWS HAVING 1-112' DUCT DIAMETER RADIUS 7. SUPPLY DUCTS: SHALL BE PER SMACNA STANDARDS FOR PRESSURE CLASS CITED. ROUND LINED DUCT SHALL CONSIST OF i -INCH ACOUSTIC INSULATION IN-BETWEEN A PERFORATED INTERIOR DUCT LiNER AND SOLID MAINTAIN POSITIVE CONCENTRICITY OF LINER WITH DUCT. INSULATION SHALL HAVE A M (MUM THERMAL CONOUCTIVITY OF 0.2$ BTU-iNCHfHR-SQ. FT. -DEGREES F AT 75 DEGREES F. UNITED-MCGILL UNITED SHEET METAL'ACOUSTt-K27 OR APPROVED. 8. MANUAL DAMPERS: SHALL BE FABRICATED OF GALVANIZED STEEL, TWO GAUGES HEAVIER THAN DUCT IN WHICH iNSTALLF0_ REGULATOR SETS SHALL HAVE QUADRANT DiAL REGULATOR WITH LOCKING NUT, SQUARE END BEARING ONE SIDE, AND SPRING OR ROUND END BEARING OTHER SIDE. 8. ACCESS DOORS: DOUBLE WALL, MINIMUM 14 GAUGE, HINGED iDR CAMLOCK ACCESS DOOR. DOORS IN INSULATED DUCT SHALL BE INSULATED TYPE. 10. DUCT INSTALLATION: INSTALL ALL DUCTWVQRK IN SIZES AND LOCATIONS AS SHOVW ON THE DRAWINGS. COMPLETE WITH ALL ACCESSORIES AND CONNECTIONS TO PROVIDE COMPLETE AND OPERABLE HEATING. VENTILATING, AIR COND)TIONING, AND EXHAUST SYSTEMS. DUCT SHALL BE INSTALLED LEVEL AND IN NEAT LINES WiTH THE BUILDING CONSTRUCTION. ALL DUCTS ARE TO BE INSTALLED CONCEALED UNLESS INDICATED OTHERWISE 11. DUCT SEALING: SEAL ALL JOINTS iN ACCORDANCE WITH SEAL CLASSIFICATION AS SHOWN IN SMACNAHVAC DUCT CONSTRUCTION STANDARDS. IN ADDITION TO APPLYING, SEALANT TO JOINTS IN ACCORDANCE WITH THE SMACNA REQUIREMENTS, ALL JOINTS AND SEAMS SHALL BE TAPED OVER WITH MINIMUM 34NCHWOE DUCT TAPE SUCH TAPE IS NOT REQUIRED ON EXPOSEO DUCTS, BUT ALL JOINT CORNERS SHALL HAVE ADHESIVE APPLIED. 12. FLEXIBLE DUCT: FACTORY INSULATED FULLY UNED FLEXIBLE DUCT. DUCT SHALL HAVE FULL INTERNAL LINER, REINFORCED WMTH ZINC COATED STEEL HELIX, LINER BONDED TO 1 -INCH THICK FIBERGLASS INSULATION, WITH MAXIMUM CONDUCTIVITY OF 0.26 5TU-INC:H1HRtiSQ FT. -DEGREE F AT 75 DEGREES AND HAVING, A POLYETHYLENE OUTER VAPOR BARRIER. PROVIDE ENDS WITH COMPRESSION CLAMPS FOR POSITiVE CONNECTION TO OVAL OR ROUND FITTINGS, SHALL COMPLY WITH NFPA 90A AND 908 AND SHALL. BE UL LISTED AND LABELED AS A CLASS 1 CONNECTOR PER UL STANDARD 161 FLEXIBLE DUCT SHALL ONLY BE USED AT DIFFUSER CONNECTION, AND SHALL NOT FiXCEED 2 FEET iN LENGTH, IN STRAIGHT RUNS ONLY (UNLESS SPECIFICALLY SHOWN OTHERWISE ON GLANS). DUCT PRESSURE RATINGS SHALL MATCH PRESSURE CLASS OF DUCT SYSTEM INSTALLER ON SECTION 25 0500 - CONTROLS 1. GENERAL: CONTROLS PROVIDER SHALL BE SIEMENS REMOVE EXISTING CONTROLS FROM DEMOLISHED UNIT. PROVIDE NEW CONTROLS FOR NEW UNIT, SAME CONTROL SEQUENCE AS EXISTING. PROVIDE ALL DOCUMENTATION OF START-UP INCLUDING POINT TO POiNT CHECKOUT SHEETS, UPDATED SEQUENCE OF OPERATION, AND UPDATED AS -BUILT DRAWINGS. SECTION 26 0540 - ELECTRICAL 1 GENERAL: ALL ELECTRICAL WORK SHALL BP PERFORMED BY WORKERS SKILLED IN THE ELECTRICAL TRADES, AND SHALL COMPLY WITH NEC AND LOCAL CODES. NOT ALL REQUIRED MATERIALS ARE SPECIFIED HEREIN OR NOTED ON THE PLANS, BUT ALL NEEDED ITEMS SHALL BE PROVIDED TO HAVE COMPLETE AND FUNCTIONING MEDICAL GAS ALARM SYSTEMS, POWER SERVICE TO TANK PAD, AND CYLINDER STORAGE ROOM LIGHTING. 2 RACEWAY: SHALL BE GALVANIZED RIGID STEEL (GRS) OR GALVANIZED FLEXIBLE STi F_L TYPE. SHALL BE INSTALLER CONCF-ALE0 EXCEPT WHERE SPECIFICALLY NOTEDAS EXPOSED RACEWAYS INSTALLED AS DIRECT BURY SHALL HAVE 15 MIL PVC COATING 3. COPPER, 600 VOLT, TYPE THW, THMI THHN OR XH14W1 WIRE MAYBE UTILIZED AT CONTRACTOR OPTION, SUBJECT TO CODE REQUIREMENTS. MINIMUM WIRE SIZE IS 12 AWG FOR POWER AND LIGHTING CIRCUITS 4, JUNCTION BOXES: SHALL BE CONSTRUCTED OF ZINC COATED STEEL, FOUR INCH SIZE MINIMUM, TYPE TO SUIT APPLICATION. S. DISCONNECTS: SHALL BE HEAVY DUTY, SINGLE THROW, LOCKABLE TYPE, HAVING DOOR INTERLOCK (TO PREVENT OPENING WHEN ENERGIZED), ENCLOSURE TO SUITE ENVIRONMENT REVIEWED FOR CODE COMPLIANCE APPROVED SEP 2 2 2016 City of Tukwila BUILDING DIVISION WSW Iigoomp i zo 2 m Rl a 11 9 F-CEIVED CIT OF TUKWILA Ptip 10ENT2 2016 M 1T ER 10 u I t r t1. i I Y •y f cl e L ' '400 to t . CL j I i O 0 C' :D' W (Jwt 00 z'aw-'O a 3� Dow F- wCL M, w z �-- CL IL ' 0 i } 0 ai 1.; I I SIGNE6 �4�43-2618 r= { L1J .�1 f Cil l =4 rz .i, 2Z it CI ZW 7'G d uj W(f) 1 W . c1 F- .- O W W }- Q I �.r y m''.' SHEET SQE 13 TRUE SCALE W-41:4 ABOVE LME MEASURES AS NOTED X J 2 3 0 5 0 B I c I o I E I F I G I H GAS METER UY PUGET SOUND ENERGY, 533 CFH AT 2PSI OU-rLET PRESSUR F ,. - -- I I I I I . �. •, - I E I 1 I 1 I I II I I �✓ LADDER ACCESS I I (E)EXHAUST FAN I I I j I II I I 1 i , HVAC -I, PROVIDE � IPLATFORM I I WlCURB ADAPTOR O.6Cd. I APPROX LOCATION OF (E) RAILING ON I DUCT PENETRATION THRU I I I PLATFORM , ROOF. ODES NOT LINE UP W) _ +� a NEW UNIT OPENINGSYP) _ - I - � - - - - - - - - � (E) SKYLIGHT (I-) EXHAUST- - � - - - - - - � _------- - -- - - -- - - - � - - - -- - --- - - - - � - I ' STRUCTURE FAN ' 1 I 1 I I I I i ROOF PLAN HVAC � 1!8. . r SCALE: ', -�} NORTH SCAlE I!8' =1W 6I - J 6 IN 0 I 1 I 1 I { I I I I t , REMOVE (E) ADAPTOR CURS 1 lits it ' � —(•tti 11 .* REMOVE (E)+40 -TON REMOVE (E) ACCESS rELECTRICOOIPLATFORM PACKAGED UNIT -- - - -T- -^ —_!- - - - tI - —>I- - - - - - - - —� - I ' II ! I I FANHAUST I I I I �tOr - I I , I I I F 71 I , -I------ - - - _ ,,__..--- - -- - - -� -�- - - - - - - -- - - - - - - --t-- - - - - - - -- i 1 (I-) SKYLIGHT (E) EXHAUST FAN I , ' 0 c 21 ff ^AK mi ROOF PLAN - DEMO mm SCALE: 1I1M'=1'-0'U d' Is* NORTH SCALE 118'a I'-0' A E F G WN H J GENERAL DOTES: 1. PRc)viDE mrr P -TRAP AND CONOENSATE PIPING ELECTRICAL NOTES: 1 PROVIDE NEW ELECTRICAL CONNECTION TO NEW UNIT. PROVIDE NEW 150 AMP BREAKER IN ELECTRICAL PANEL BELOW GENERAL NOTE : I SEE GENERAL DEMOLITION NOTES ON SHEET MO -M1.0 2 EXISTING UNIT 18 A 40 -TON TRANS VOYAGER ELECTRIC HEAT, ELECTRIC COOL UNIT, MODEL TCD48044.. APPROX 87+99 LBS. (PER 00-08-05 BELLEVUE MECHANICAL AS -BUILT DRAWNGS). 3 REMOVE EXISTING CONTROLS AND POMR CONNECTIONS TO EXISTING UNIT. REMOVE DUCT CONNECTIONS ELECTRICAL NOTES: 1 REMOVE EXISTING ELECTRICAL CONNECTION TO UNIT REMOVE EXISTING BREAKER IN ELECTRICAL PANEL BELOW Is E_\At VED FOR CODE COMPLIANCE APPROVED SEP 2 2 2016 City of Tukwila BUILDING DIVISION PERMIT SET � I K K 3 0 5 2 9 9 REC-EWEI TY OF TUK SEP 12 2( ERMI i CEN A 0 —i K Ell z A � g UNIT SA CONNECTION LOCATION DIVIDER PLENUM TO ALLOW NEWOPENING LOCATIONS TO FUNCTION c HVAC -1 0 ^-„-y 1 I j i EXISTING CURB I r r I r I 1 EXISTING SA DUCT EXISTING? RA DUCT SI DE ELEVATION- EW UNIT RA CONNECTION LOCATION (E) ROOF r------- ------------------ i � REMOVE (E) UNIT r I � � I Lr-------_.—_.---------------.r.� REMOVE (E)CURBS EXISTING CURB -- tE] RC?{7F _..._' SIDE ELEVATION- DECO 0 F OFFSET CURB ADAPTOR To PROVIDE 48" CLEARANCE FROM (E) SKYLIGHT STRUCTURE G HVACA EXISTING CURB I PROVIDE WORKING PLATFORM WTH GUARD ON ONE SINE. 2.5'X2.5' ANGLE IRON VNTH STEEL GRATING, ALL HOT DIP GALVANIZED r (E) SKYLIGHT STRUCTURE jJ STEEL LADDER ACCESS J TO PLATFORM ESD ELEV,ATFO("'I' - NEW r ----------I REMOVE EXISTING REMOVE (E) UNIT i I PLATFORM I I � REMOVE (E) CURBS L �.-- - EXISTING CURB ROOFTOP UNIT ELEVATIONS SCALE. 1/4'7= 1'.Cr C.7 (6 M3.3 -- ROOF 6 10 END ELEVATIOIq - DE iO (E) SKYLIGHT STRUCTURE SIZE TO MATCH UNIT CONN (UNCI) EXTEND REGULATOR VENT FULL SIZE MINIMUM OF 10, FROM ADJACENT AIR INTAKE$ a 1'ASOVE GAS REGULATOR, SIZED FOR 2 LBS IN, 7' W.C. OUT. CAPACITY 70 MATCH UNIT � CAPACITY (U NO) SIZE PER PLAN I G MIN 6" DRIP LEG nt1c: n 1 1 U ALLVVV KQQM FOR DRIP LEG REMOVAL ROOFTOP UNGAS COAL I (E) ROOF (E) ROOF UNIT CURB NTS MU M4.1 s o 1 m c6 I tito Ln 2c8 .0 Im F v }i t t 3 T: t 4 < W0 r co ?.>cr) _ `'C oil woi j = Fry LU T 0 CL T 6 REVIEWED FOR CODE COMPLIANCE APPROVED SEP 2 2 2016 City of Tukwila BUILDING DIVISION SIGNED f til r O 6 W Q) W { ILL! LU C) W" }C fn 10 REVIEWED FOR CODE COMPLIANCE APPROVED SEP 2 2 2016 City of Tukwila BUILDING DIVISION m 0 i.x Am. 10 { i1 PERMIT SET I' SHEET 512E IS TRVE SCAEE WHEN 1 { ABOYE ur.£ WEi SJRES 115 NOTIjO A� r I � � ! F G P K } _C Y f til r O W w fn 10 I �1 E m 0 i.x Am. 10 { i1 PERMIT SET I' SHEET 512E IS TRVE SCAEE WHEN 1 { ABOYE ur.£ WEi SJRES 115 NOTIjO A� r I � � ! F G P K } _C J A r C E G H i K L 5 P 7 6 10 E 11 PROJECT NOTES OMER: KING COUNTY HOUSING AUTHORITY (ANDOVER PARK WEST` TUKWILLA, 98188 CONTRACTOR: JOHNSON CONTROLS 4011 S.E. INTERNATIONAL WAY SUITE 605 MILWAUKEE, OR 97222 PROJECT MANAGER: VEERA VIJAY P.E. CEM 206_85D.A742 Yee ramijayaraghavanfti.cam ENGINEER: HULTZIBHU ENGINEERS 1111 FAWCETT AVENUE SUITE 100 TACOMA, WA 98402 PRIMEIMECHANICAL CONTACT: MICHAEL TAGLES, P.E. ELECTRICAL CONTACT: TOM URQUHART, RE STRUCTURAL ENGINEER: PCS STRUCTURAL SOLUTIONS 1250 PACIFIC AVE #7071 TACOMA. WA 98402 253.383.3257 FAX: 253.3$3.32$3 michaatt@)huhzbhu.com 251383.3257 FAX: 253.383.328 tomu@hultzbhb.com CONTACT; GARY BECKNER: P E 253-383.2797 GbL-ckner@psc-stL,ctural.com F— PROJECT GENERAL NOTES 1 ALL ITEMS ARE NEW UNLESS SPECIFICALLY NOTED AS EXISTING, 2 ALL WORK IS 13ASE BID UNLESS SPECIFICALLY NOTED AS ALTERNATE BID WORK. 3. REVIEW OF EXISTING CONDITIONS IS REQUIRED. 4. BUILDING IS OCCUPIED DURING CONSTRUCTION, UTILITY OUTAGES MUST BE AUTHORIZED BY OWNER, NO NOISE GENERATING ACTIVITIES BSPAIEEN 5 Phi AND 7 AM F DESCRIPTION OF WORD REPAIR HVAC SYSTEM AT MULTIPLE SITES IN KING COUNTY, LIST OF DRAWINGS G1.0 COVER SHEET MA)N OFFICE - (MO) M041,10.1 MECHANICAL LEGEND & NOTES MO -M1:0 SCHEDULES & SPECIFICATIONS MO -M4.0 ROOF PLAN MO -M4.1 DETAILS BRIAFRWOOD - (BVV) W.1 !,MECHANICAL LEGEND & NOTE -WO SCHEDULES & SPECtFICATTIO S SE— IAR.,T E P - ,`SIT l Olr,1Is' :-:D FOR: 0 IN-lechanica! 13,6cctrical 0 -Plumbing `J<✓`-`" pvmg 7 C-17 Cf Tulaw"'.a 5 no M4.0 ROOF PLAN YA-M1: SCHEDULES b SPECIR ATIONS LA OUSE - (LH) ROOF PLAN FRE COPY LH -#M0. MECHANICAL LEGEND QTES ,44x11.0 SCHEDULES & SPECIFICATIO LH -M1. SCHEDULES & SPECIE ATIONS�■ Perm 1 D LH -M4.0 ROOF PLAN .-M[.L NQRTiIRI N1-MO.1 1 -(N1) I CHANICAL LE ND & NOTES Flan ioYi3�1V �s ilC�%Pi !9 subject 1 ct to errors and omissions. N1 -M1.0 SC EDULES & ECIFICATIONStf-;r0'2I cf co 'Siri_�-:{ion documents does not aul:hoCize NI -WO R PLAN the Viciation Li ,.ny adopted code or ordinance. Pii000ipt N2 -M0,1 b(3E 2 . ( ) N2 -M0,1 MEGHAI LEGEND 8 NOTES of a f'ovod F, ., FP " � -- � •� d Copy and condiiaons is acknowledged: N2 -M1 o SCHEDU S & SPECIFICATIONS N2 -M4.0 ROOF By: SOUTHRIDGE H SE-( ) Date: — �� SR-MO.1 ME ICAL L GENA & NOTES z SR1.0 EDULES & S ECIFICATIONS SR:M?,14.0 F PLAN City of Tukwila YARDLEY RIMS - (YA) BUILDING DIVISION "—"- YA--N10.1 MECHANICAL LEGEN & NOTES YA-M1: SCHEDULES b SPECIR ATIONS YA-M :0 ROOF PLAN TMINSTER MANOR - MIA) 1-M0.1 MECHANICAL LEGEND & NO S ,44x11.0 SCHEDULES & SPECIFICATIO -M4.0 ROOF PLAN i APPROVALS chan� _ ---- of w^ to the s^npP _ TL "?Proval of `visiOn_ m ay i '-3wpl n submittal rev; REVIEWED FOR CODE COMPLIANCE APPROVED t SEP 2 2 2016 City of Tukwila BUILDING DIVISION 9 RECEIVED CITY OF TUKWILA SEP 12 2016 PERMIT CENTER 10 PERMIT SET C4 a <m ' 63 Cn w IZ 0 t WN n CL w (D z LL W W 0-01 0 `. CL ' _z LEO SIGNED d3.03-2DiS� t0 W z z Q � x cn W o a W e- I -- O Z e T W V3 C3 Q tL M, P/M S1 ET SIZE IS TRUE SCALE VN'I-EN: ASOVE LINS MEASURES AS NOTED J 0) 3 r 5 LTJ 7 �061 6 10 0 A B C Bellevue Jittl �,. WESY SEL t.EVj. � .j 1 ~ice .r Mercer Isimid ! CC) LUt UIt, Cir}' fi ' Newcastle ` t mount Regiol 7 7 �•� 4tr0rar7d White Center Coalfield ' Renton Highlands Tukwila 11x �.-=- 3 mapI 600 Andover Park W Heights - x SeaTac# Cascade-Faimood i1 Notmandy F rilt�a rt u Park t � East WJRK LOCATION VICR41TY SAP NTS F NORTH E I F I G I H AERIAL 'VIEW ^AR NTS NORTH SITE ADDRESS: KING COUNTY HOUSING AUTHORITY MAIN OFFICE 600 ANDOVER PARK WEST TUKWILLA, WA 98141 BLDG DATA: OCCUPANCY: R-2 (NO CHANGE) SPRINKLERED: YES (NO CHANGE) FIRE ALARM: YES (NO CHANGE) SCOPE OF WORK: 1 REPLACE EXISTING ELECTRIC ROOFTOP HVAC UNIT WITH NEW GAS FIRED ELECTRICAL COOL ROOFTOP HVAC UNIT E HA I AL E "ERAL DE OLITIO NOTES 1. DEMOLITION DRAWINGS NOTES ARE INTFNDED TO ONLY GIVE A GENERAL REPRESENTATION OF THE DEMOLITION INVOLVED, AND DO NOT CONSTITUTE A FULL LISTING OF ALL ITEMS REQUIRING REMOVAL NOT ALL ITEMS TO BE DEMO'D ARE SHOWN. CONTRACTOR IS RESPONSIBLE TO REVIEW EXISTING CONDITIONS. EXISTING DRAWINGS, AND MECHANICAL GENERAL DEMOLITION NOTES. 2 IT IS THE CONTRACTOR'S RESPONSIBILITY TO REVIEW SITE CONDITIONS AND TO IDENTIFY ALL DEMOLITION WORK, AND INCLUDE IN HIS BID ALL COSTS FOR DEMOLITION & DISPOSAL NOT ALL ITEMS TO BE DEMO'D ARE SHOWN: SEE GENERAL NOTES FOR REQUIREMI-NITS. 3. EXIST. DUCTS, EQUIPMENT. PIPING, AIR INLETSIOUTLETS, SHOWN DASHED REPRESENT MAJOR MECHANICAL. ITEMS TO 13E REMOVED SEE GENERAL NOTES. DRAWING NOTE=S 5 KEYED NOTES WHICH COVER ALL OTHER MISC. MECHANICAL ITEMS TO BE REMOVED. A ALL EXIST ITEMS NOT BEING REUSED SHALL BE REMOVED. THIS INCLUDES SUCH ITEMS AS THERMOSTATS, CONTROL DEVICES, CONTROL WIRING, PNEUMATIC TUBING, DUCTS, FANS, PIPING, SUPPORTS, VALVES, CURBS, AND RELATED ACCESSORIES. 5. PROVIDE TEMPORARY CAP -OFF OF ALL EXIST. SYSTEMS TO ALLOW CONTINUED USE OF ALL SYSTEMS UNTIL THE FINAL- SYSTEM COMPONENTS ARE INSTALLED AND CONNECTED S "OLD ALL REMOVED ITEMS FOR OWNERS REVIEW. ITE=MS SELECTED BY OWNE=R FOR SALVAGE SHALL BE MOVED BY THE CONTRACTOR TO THE OWNERS STORAGE ROOM (VERIFY EXACT LOCATION WITH OWNER). ITEMS NOT SELECTED BY OWNER FOR SALVAGE SHALL BE DISPOSED OF CFF SITE IBY CONTRACTOR. 7, ROUTING SHOWN OF EXISTING ITEMS IS APPROXIMATE= CONTRACTOR SHALL FIELD VERIFY LOCATIONS CONTENTS, AND FLOW DIRECTION OF ALL PIPING � DUCTS. LABELING SHOWN ON PLANS HAS NOT BEEN VERIFIED 8 _ SEE FLOOR PLANS FOR RECONNECTION OF NEW PIPING AND OUCTWORK. A I B I C I p I E I F K MECHANICAL LEGEND SYMBOL DESCRIPTION ABBREV. DESCRIPTION 201 p DUCT (FIRST FIGURE, SIDE SHOWN) AFF APPROX. ARCH AUTO) BOO 13TU BTUH BLDG C CAP CLG ABOVE FINISHED FLOOR APPROXIMATELY ARCHITECTURAL AUTOMATIC BACK DRAFT DAMPER BRITISH THERMAL. UNIT BRITISH THERMAL UNIT/HOUR BUILDING CONDENSATE CrAPACII Y CEILING 2a�2t 24„2t' LINED DUCT (DIM FOR NET FREE AREA) EOL= END i_' = r OF LINING TRICK LINING � R RISE (R) OR DROP ('D) ARROW IN DIRECTION OF FLOW cv DUCT SECTION (SUPPLY) ® DUCT SECTION (EXHAUST OR RETURN) 0 ROUND DUCT, DIAMETER CO CLEANOUT W Y VOLUME DAMPER (MANUAL) CONN CONNECTION Z CONT CONTINUE, CONTINUATION 0 a DAMPER CFM CUBIC FEET PER MINUTE LztMOTORIZED z DEG F, F° DEGREE FAHRENHEIT FLEXIBLE CONNECTION DIA, 0 DIAMETER DN DOWN BACK GRAFT DAMPER (BDD) DVVG DRAWING DS DRY BULB FLEXIBLE DUCT EA EACH EER EFF ELEC EOL ENERGY EFFICIENT RATIO EFFICIENCY ELECTRICAL, ELECTRIC END OF LINING FIRE DAMPER COMBINATION FIREISMOKE DAMPER II ELBOW WITH TURNING VANES XH EXIST. (E) EXHAUST EMSTING ���,ESts»�,t3at C� CEILING OUTLET' ESP FPM EXTERNAL STATIC PRESSURE FEET PER MINUTE CEILING INLET FLET{ FL FCC? FLA GAL GALV. GI HP INTEGR. IN KW MPEG MAX FLEXIBLE FLOOR FLOOR CLEAN OUT FULL LOAD AMPS GALLON GALVANIZED GREASE INTERCEPTOR HORSE POWER INTEGRAL INCH KILOWATT MANUFACTURER MAMMUM IStZE,sYMt3t>t. ---� WALL OUTLET (OR INLET) 7 OA G= WITH GUARD THERMOSTAT A= AVERAGED WITH OTHER (D SWITCH INTERVAL TIMER - - c -� ----- CONDENSATE LINE G GAS LINE MBH MECH THOUSAND BTUH MECHANICAL MIN MCA MINIMUM MINIMUM CIRCUIT AMPS MUA MAKE UP AIR MFS MINIMUM FUSE SIZE NIC NOT IN (CONTRACT NO, NUMBER NTS NOT TO SCALE OA OUTSIDE AIR OBD 0PP0$ED BLADE CLAMPER PH PHASE -PD PRESSURE DROP POC POINT OF CONNECTION RA RETURN AIR REF REFERENCE REO'D REOUIRED RLA RATED LOAD AMPS RPM REVOLUTIONS PER MINUTE RM ROOM $A SUPPLY AIR S.O. SCREEN OPENING TEMP TEMPERATURE TD TRANSFER DUCT TG TRANSFER GRILLE TYP TYPICAL UNC? UNLESS NOTED OTHERWISE V VF0 VOLTS. VOLTAGE, VENT VARIABLE FREQUENCY DRIVE WA WB WATT WET BULB 2 M3)�j DETAIL IDENTIFICATION NUMBER SHEET ON WHICH DETAIL IS SHOWN WL W1 WALL LOUVER WITH A SECTION IDENTIFICATION LETTER M3 �4 SHEET ON WHICH SECTION IS SHOWN i IE HA IAL GENERAL NOTES 1 ALL PIPING & DUCTWORK SHOWN IS SCHEMATIC. CONTRACTOR SHALL PROVIDE ALL OFFSETSIELBOWS AS REO'D TO ALLOW ROUTING AROUND STRUCTURE, ELECTRICAL, & OTHER INTERFERENCES 2. SALANCING NOTES: PROVIDE AIR BALANCING OF HVAC SYSTEM, SEE SECTION AND 23 05 93 FOR COMPLETE REGUIREMENTS 3 ALL PIPING AND DUCTWORK SHALL BE RUN CONGEALED, UNO h. PROVIDE TRANSITIONS FROM DUCT SIZES INDICATED TO CONNECTION SIZES AT EQUIPMENT. WHERE THE CONNEC;TINC; DUCT IS LINED, THE TRANSITION SHALL BE LINED USE Z' LINING (UNO) G it 2 3 a1 0 R u n s C') 0, a 0 ;Se Dzi�< W (000 ' C3) =--�Z z _~N. Lj%61- �- -- , Z10 WD �— I.L. _ILL 0 SIGNED 46.03-2016 Q) c C? L .. j C Uj tCi c� E ur E W2 x.o �w� f � C cv En .Q 2016 t s C') 0, a 0 ;Se Dzi�< W (000 ' C3) =--�Z z _~N. Lj%61- �- -- , Z10 WD �— I.L. _ILL 0 SIGNED 46.03-2016 Q) c C? W Uj F- MED w Y OZ C -UKWILA En L^t 2016 t .F I1.I W Y Z W 0 a LU F- z 9 c C? Uj MED w Y C -UKWILA En L^t 2016 t GENTER E` x= i r In i I _j K CI 10 0 J Co • ue 10 mr ROJ E OT PSE C I F ICIAATlOr4b 1. SECTION 23 1123 -GAS PIPING 2 STEEL PIPE FITTINGS. A THREADED FiTTLNGS• MALLEABLE IRON PER ASME B18 3- CAST IRON PER ASME 816.4. 3 GAS PIPING: SCHEDULE 40 STEEL PIPING {COMPLYING VMTH ASME A53} Wr~dTH THREADED CLASS 125 FITTINGS. 4. ZUL LISTED FOR GAS SERVICE. BRONZE TWO-PIECE BLOWOUT PROOF STEM, FULL PORT. NIBCO T -685 -70 -UL. 5. RATED AT MINIMUM 125 PSIG AT 200 DEGREES F; PROVIDE DIELECTRIC UNIONS WHERE DISSIMILAR METALS JOIN. PROVIDE UNIONS AT CONNECTIONS TO ALL EQUIPMENT 6. INSTALLATION: FOLLOW ESTABLISHED PROFESSIONAL PRACTICES FOR JOINING OF PIPING AND STT AS TO SUIT THE SYSTEM PRESSURES AND TEMPERATURES INVOLVED. 7. SECTION 23 81 53 - HVAC UNITS 8. HVAC UNITS ROOFTOP PACKAGED GAS HEAT ELECTERiC COOL ROOFTOP UNIT$ WITH AS A MINIMUM SCHEDULES CAPACITY. SEE SCHEDULE FOR ACCESSORIES MANUFACTURER AND MODELAS SCHEDULED. 9. PROVIDE WiTH 0-100% OA ECONOMIZER AND CUSTOM ROOF ADAPTOR CURB ENERMY COBE. - HVAC 1 LOAD CALCULATIONS HAVE BEEN PERFORMED IN ACCORDANCE WITH WSEC C4032.1..OR EQUIPMENT IS SELECTED AT SAME CAPACITY AS THE UNIT BEING REPLACED. 2 EQUIPMENT HAS BEEN SELECTSI3 PER WSEC 0403.2.2 3 VENTILATION AND THE ABILITY TO REDUCE OUTSIDE AIR TO IMG MINIMUM$ SHALL BE PROViDED PER WSEC 0403 2 5. 4 MOTORS i HP AND LARGER SHALL BE ENERGY EFFICIENT TYPE PER VVSEC C403.2.13: MOTORS 1112 HP TO 1 HP SHALL BE EiCM *TYPE OR MEET L41NIMUM EFFICIENCY REQUIREMENTS PER WSEC C403.2.10.3. S. TEMPERATURE CONTROL SYSTEM SHALL HAVE A MINIMUM DEAD BAND OF 5 DEGREES AS REQUIRED BY WSEC 0403.2.4.2. 6. HVAC SYSTEMS SHALL BE EQUIPPED VIATH AUTOMATIC CONTROLS CAPABLE OF PROVIDING NIGHT SETBACK. SEVEN DIFFERENT DAILY SCHEDULES, AND OPTIMUM START PER THE REQUIREMENTS OF WNSEC C403.2 4.3 7 OUTSIDE AIR INTAKES, EXHAUST OUTLETS, AND RELIEF OUTLETS SHALL BE PROVIDEDWMTH DAMPERS THAT COMPLY WITH WSEC C403.2.4.4. DAMPER SHALL AUTOMATLCALLY CLOSE VVI-IEN SYSTEM OR SPACES SERVED ARE NOT IN USE OR DURING WARM-UP. COOL4)OWN, AND SETBACK DAMPER MAXIMUM LEAKAGE RATE SHALL NOT EXCEED MAXiMUM ALLOWED BYVVSf:C 0402.4.52 a COMBUSTION HEATING EQUIPMENT WITH A CAPACITY OVER 225 MBH SHALL HAVE MODULATING OR STAGED COMBUSTION CONTROL PER WSEC C+403.Z4.6. 9. FAN SYSTEMS SERVING A ZONE OR MULTIPLE ZONES WViTHOUT SEPARATING WALLS WMTH TOTAL AIRFLOVV OVER 10,E: W CFM SHALL REDUCE AIRFLOWWi BASED ON SPAC E HEATING AND COOLING DEMAND PER WSEC 0403.2.122 10. ALL DUCTIM(3RK SHALL BE CONSTRUCTED AND SEALED IN ACCORDANCE VATH IMC, MEC C402 AND LSC REQUIREMENTS PER MEC C403.2.7. 11 DUCTS AND PLENUMS DESIGNED TO OPERATE AT A PRESSURE ABOVE 3' W.C. SHALL BE LEAK TESTED PER WNSSC 0403.2 7.3.3. DOCUMENT AND SUBMIT TEST RESULTS TO THE AHJ AS REQUIRED 12. DUCTWORK SHALL BE INSULATED TO THE APPROPRIATE R -VALUE AS REQUIRED BYyti EC 0403.2 7. 13 PROVIDE HIGH LIMiT SHUT-OFF CONTROL OF ECONOiySIZER COOLING PER TABLE C403.3.1.1.3(2) 14 ECONOMIZER DAMPERS SHALL BE CAPABLE OF BEING SEQUENCED WITH MECHANICAL COOLING EQUIPMENT. ECONOMIZERS ON SYSTEMS WViTH COOLING CAPACITY GREATER THAN 65 MBH SHALL BE CAPABLE OF PROVIDING PARTIAL COOLING PER MEC 0403.3.1.1.2 15. ECONOMIZER CONTROLS SHALL BE SUCH THAT ECONOMIZER OPERATION DOES NOT INCREASE BUILDING HEATING ENERGY DURING NORMAL OPERATIONS PER WSEC C403,4.1.4, AND SHALL BE INTEGRATED WITH MECHANICAL COOLING SYSTEM AND BE CAPABLE OF PROVIDING PARTIAL COOLING PER WSEC 0403.4.1.3 16. FORVAV SYSTEMS WITH ODD, PROVIDE STATIC PRESSURE RESET PER VWSEC 0403.4.2.2 17. SUPPLY ALR SYSTEMS SERVING MULTIPLE ZONES SHALL BE VAV TYPE DESIGNED AND CAPABLE OF $EING CONTROLLED TO REDUCE PRIMARY AiR SUPPLY TO EACH ZONE TO A MAXIMUM FLOW RATE AS ALLOWED BY WSEC 0403 4 5. IS. HVAC SYSTEMS NTH MULTIPLE ZONES SHALL REQUIRE TEMPERATURE RESET CONTROLS MICH AUTOMATICALLY RESET SUPPLY AIR TEMPERATURES PER WSEC 0403.4.5.4. 19. COOLING SYSTEMS SHALL. NOT USE HOT GAS BYPASS OR OTHER EVAPORATOR PRESSURE CONTROL SYSTEMS UNLESS THERE ARE MULTIPLE STEPS OF UNLOADING, HOT GAS BYPASS CAPACITY SHALL BE LIMITED PER TABLE 0403.4.7. DOES NOT APPLY TO UNITARY PACKAGED SYSTEMS 90 MBH OR SMALLER 20. AIR SHALL BE BALANCED AS REQUIRED IN SECTION 0408 2.21 AND C408.2.2 2 OF THE WSEC 21. PROVIDE COMMISSIONING PLAN 8 REPORT REQUIREMENTS FOR PRELIMINARY MID FiNAL COMMISSION048 PER SECTION C408.1. PROVIDE SECiLIENCE OF OPERATIONS AND TEST PROCEi3URES PER SECTION C•4U6.1.2 AND SUBMIT COMPLIANCE CHECKLIST PER SECTION 0108.1 3 4 OF THE WSEC TO THE BUILDING OFFICiAL UPON SUBSTANTIAL COMPLETION. 22. THESE'ENERGY CODE NOTES' ARE LiSTED TO SATISFY THE BUILDING DEPARTMENTS REQUIREMENT THAT CERTAIN INFORMATION BE PLACED ON THE PIANS, BUT DO NOT DIMINISH THE FULL PROJECT REQUIREMENTS PROVIDE ITEMS IN EXCESS OF CODE WHERE NOTED ON DRAWINGS AND IN SPECIFICATIONS. FOR OTHER ADDED REQUIREMENTS, SEE SPECIFICATIONS. SECTION 010000 -GENERAL 1. CODE CCMPLIANCE- ALL WORK SHALL COMPLY WITH ALL LOCAL CODES AND ORDINANCES 2 DRAW NGS. DRAW NGS ARE DIAGRAMMATIC AND SHOWN THE GENERAL ARRANGEMENT OF THE CONSTRUCTION, AND THEREFORE DO NOT SHOW ALL NECESSARY OFFSETS, FITTINGS, ALTERATIONS TO EXISTING ITEMS, AND ACCESSORIES WHICH ARE REQUIRED TO FORM COMPLETE AND OPERABLE SYSTEMS. 3 FIELD VERIFICATION: THE CONTRACTOR SHALL BE RESPONSIBLE FOR CHECKING FIELD CONDITIONS AND VERIFYING ALL MEASUREMENTS AND RELATIONSHIPS INDICATED ON THE DRAWINGS BEFORE SUBMITTING BIDS AND AGAIN BEFORE PROCEEDING WITH THE WORK 4. NOTiFY THE ARCH ITECT1ENGINEER OF ANY CiISCREPANCIES OR CONFLICTS BEFORE PROCEEDING WITH ANY MRK OR THE PURCHASING OF ANY MATERIALS FOR THE ARENS) OF CONFLICT UNTIL REQUESTING AND OBTAINING VVR ITTEN INSTRUCTIONS FROM THE ARCHITECTIENGINEER ON HOWTO PROCEED. WHERE CONFLICTS OCCUR, THE MOST EXPENSIVE AND STRINGENT REQUIREMENT(AS JUDGED BYTHE ARCHiTEICTIENGiNEER) SHALL PREVAIL. ANY WORKDONE AFTER DiSC,0VERY OF SUCH DISCREPANCIES OR CONFLICTS AND PRIOR TO OBTAINING THE ARCHITECTIENGINEER'S INSTRUCTIONS ON HOW TO PROCEED SHALL BE DONE AT THE CONTRACTOR'S EXPENSE. 5 DRAVWiNGS AND SPECIFICATIONS. DRAWINGS AND SPECIFICATIONS ARE COMPLEMENTARY AND WHAT IS CALLED FOR IN EITHER IS BINDING AS IF CALLED FOR IN BOTH. THE DRAWINGS ARE DIAGRAMMATIC AND SHOWTHe OENeRAL ARRANGEMENT OF THE CONSTRUCTION AND THEREFORE DO NOT SHOWALL- OFFSETS, FITTINGS AND ACCESSORIES MICH ARE REQUIRED TO FORM A COMPLETE AND OPERATING INSTALLATION. MECHANICAL WORK IS SHOWN ON MULTIPLE DRAWNNOS AND IS NOT LIMITED TO A PARTICULAR SET OF SHEETS, OR SHEETS PREFACED VOTH A PARTICULAR LETTER. 6. PERMITS AND FEES: THE CONTRACTOR SHALL OBTAIN AND PAY FOR ALL PERMITS. LICENSES, FEES AND INSPECTIONS AS REQUIRED 6Y THE GOVERNING CODES AND AS SPECIFIED HEREIN. 7. SUBMITTALS: CONTRACTOR SHALL SUBMIT SHOP DRAWW INGS FOR ALL PRODUCTS PROPOSED TO BE USED ON THIS PROJECT FOR OWNER REVIIEW- PRODUCTS SHALL NOT BE USED UNTIL APPROVED BY THE OVWMER OR HIS REPRESENTATIVE. SUBMIT 3 COPIES PLUS ANYADVITiONALQUANTITIES THE CONTRACTOR NEEDS (3 COPIES %MLL BE RETAINED BY THE OWNER). 6 RECORD DRAWINGS: THE CONTRACTOR SHALL MAINTAIN A SET OF CONTRACT PLANS AT THE PROJECT SITE UPON WHICH ALL CHANGES FROM THE AS -BID PLANS ARE NOTED. AT THE. COMPLETION OF THE PROJECT, THE CONTRACTOR SHALL DELIVER TO THE OWNER ONE COMPLETE SET OF THESE RECORD DRAWINGS. 9. PROTECTION: CONTRACTOR IS RESPONSIBLE FOR PROTECTION OF ALL MATERIAL, FOUIPMENTANDAPPARATUS PROVIDED UNDER THIS SECTION FROM DAMAGE. WATER, CORROSION, FREEZING AND DUST, BOTH IN STORAGE AND WHEN INSTALLEO, UNTIL FINAL PROJECT ACCEPTANCE 10 COORDINATION THE CONTRACTOR SHALL COORDINATE ALL CONSTRUCTION ACTIVITIES WITH THE OWNER AND COOPERATE FULLY SO AS TO MINIMIZE CONFLICTSAND TO ALLOW FULL OWNER USAGE (UNLESS INDICATED OTHERWIWiSE) OF ALL AREAS DURING CONSTRUCTION 11. CUTTING AND PATCHING: SHALL BE DONE BY SKILLED LA13OR EXPERIENCED IN PROVIDING OPENINGS AND PATCHING OF THE MATERIALS INVOLVED. AREAS SHALL BE PATCHEDAND RESTORED TO AFiNISHEO CONDITION, EQUAL TO ADJACENT FINAL FINISHED AREAS THAT HAVE NOT BEEN CUT 12. PAINTING: SHALL BE PROVIDEO VMERE INDICATED, BY SKILLED PAINTERS IN CONFORMANCE WITH STANDARD PROFESSIONAL PRACTICE INCLUDING CLEANING AND PRIMING OF MATERIALS TO BE PAINTED. COLORS SHALL BE SELECTED BY THE OWNER 13. FINAL INSPECTION: PRIOR TO ACCEPTANCE OF THEWORK THE CONTRACTOR SHALL PUT ALL SYSTEMS INTOOPERATION FORA PRRIOD OF NOT LESS THAN S WORKING DAYS 60 THAT THEY MAY BE INSPECTED BY THE OVWER. 14 INSTRUCTION! O S M MANUALS: DURING THE FINAL iNSPECTION PERIOD, THE CON7RAC70R SHALL PROVIDE INSTRUCTIONS AND DEMONSTRATIONS FOR THE OWNER'S REPRESENTATIVES ON THE OPERATION AND MAINTENANCE OF ALL EQUIPMENT, AND PROVIDE 3 SETS OF O&M MANUALS. O d M MANUAL SHALL INCLUDE CONTACT INFORMATION FOR CONTRACTOR AND MAJOR EQUIPMENT SUPPLIERS. INCLUDE A COPY OF THE PRODUCT SUBMITTAL DATAFOR ALL MAJOR EQUIPMENT ITEMS WITH THE 0 Iii M DATA. INCLUDE SPACE FOR REDUCED SIZE AS -BUILT DRAWINGS 15 WARRANTY: ALL WORK ANO EQUIPMENT SHALL BE WARRANTED TO BE. FREE FROM DEFECTS AND CAPABLE OF PROVIDING SATISFACTORY OPERATION FOR A PERIOD OF ONE YEAR AFTER FINAL ACCEPTANCE: 16 NEVWtMATERIALS: ALL ITEMS ARE NEW UNLESS SPECIFICALLY NOTED AS ENST'ING 17. COMPLETE SYSTEMS: NOT ALL NECESSARY MATERIALS TO PERFORM T89 WORK REQUiRED ARE SPECIFIED OR SHOWN- CONTRACTOR SHALL, PROVIDE ALL ITEMS NEEDED TO HAVE COMPLETED PROPERLY OPERATING SYSTEMS, ITEMS PROVIDED SHALL BE OF COiyAMERCIAL ANSTITUTiONAL QUALITY, CONSISTENT WiTH THE QUALITY OF RELATED ITEMiS PROVIDED ON THE PROJECT OR CURRENTLY BEING USED IN THE BUILDING. IS OFFSETS AND FITTINGS INCLUDE IN BILI ALL NECESSARY FITTINGS AND OFFSET TO COMPLETELY CONNECT UP ALL SYSTEMS, MAINTAIN CLEAR ACCESS PATHS TO EQUIPMENT, AND COMPLY WiTH ALL PROJECT REQUIREMENTS. OFFSETS ARE REQUIRED TO ROUTE. AROUND BUILDING STRUCTURAL ELEMENTS. ROOF SLOPES, MECHANICAL SYSTEMS, ELECTRICAL SYSTEMS, AND NUMEROUS OTHER ITEMS. DUE TO THE SCHEMATIC NATURE OF THE FLANS $UGH OFFSETS ARE TYPICALLY NOT SHOWN. CONTRACTOR IS RESPONSIBLE TO DETERMINE THE QUANTITY OF OFFSETS AND FITTINGS REQUIRED. AND THE LABOR INVOLVED. NO ADDED PAYMENT OR'EICTRAS' WILL BE GRANTED FOR THE CONTRACTOR'S FAILURE TO CORRECTLY ESTIMATE THE NUMBER OF OFFSETS AND FITTINGS AND LABOR REQUIRED. CONTRACTOR IS ADVISED THAT EQUIPMENT AND CONNECTIONS MAY REQUIRE MORE OFFSETS AND TRANSITIONS 19 CONTRACTOR LAY -OUT: THE CONTRACTOR IS REQUIRED TO DO FURTHER LAYOUT TO FINALIZE THE DESIGN SHOtM+1 ON THE PROJECT DRAWINGS. SUCH MRK INCLUDES FIELD INVESTIGATION OF ALL EXISTING CONDITIONS, LAYOUT SKETCHES TO VERIFY RISES AND ORCIPS IN PIPING AND DUCTWORK, COORDINATiON. OF ELEVATIONS %NITH OTHER TRADES, AND NOTIFYING OTHER TRADES OF ITEMS TO BE RELOCATED. ETC. 20. ALL ITEMS REQUIRING MAINTENANCE SHALL BE ARRANGED TO BE ACCESSIBLE A I B I E GE E TIONS SECTION 02 00 DO - SITEVMRK I. SITE CLEARING: CLEAR SITE AS NEEDED FOR NEW TRENCHING AND PAO INSTALLATION. DISPOSE OF ALL MATERIAL OFF SITE. PROVIDE PROTECTION OF AOJACENTAREA4S FROM DUSTIDIRTINOISEIEROSiON AND OTHERADVERSE AFFECTS DUE TO CONSTRUCTION. REPAIR ALL DISTURBED AREAS TO RE -CONSTRUCTION CONDITION OR BETTER. SECTION 06 10 00- ROUGH CARPENTRY 1. FRAMING AND TREATED LUMBER: DOUG-FIRILARCH NO- 2OR HEM -FIR NO.1 OR BETTER, MINIMUM F=1200 PSI (SINGLE USE). CONFIRM TO WEST COAST LUMBER INSPECTION 8UREAL UB OR WE WOOD (WCUB) PRODUCTS ASSOCIATiflN (VWMtPA). EACH PIECE OF LUMBER SHALL BEAR THE VVCLIS OR ~A GRADE TRADEMARK 2 FRAMING CONNECTORS AND BRIDGING: SHALL BE [.C.B.O. APPROVED AND SHALL BE MANUFACTURED BY SIMPSON OR BOWMAN OR APPROVED EQUAL, FURNISHED COMPLETE WITH ANY SPECIAL NAILS REQUIRED ALL FRAMING CONNECTORS SHALL. BE HOT -DIPPED GALVANIZED. 3. ROUGH HARDWARE' PROVIDE ROUGH HARDWARE OF THE TYPE AND SIZE NECESSARY FOR THE PROJECT REQUIREMENTS. SIZES. TYPES, AND SPACING OF FASTENINGS OF MANUFACTURED BUILDING MATERIALS SHALL SE AS RECOMMENDED BY THE PRODUCT MANUFACTURER UNLESS OTHERWISE INDICATED OR SPECIFIED. 4. PLYWOOD. GROUP 1 OR GROUP 2 SPECIES, C -D GRADE EXPOSURE 1 CONFORMING TO PS 1-83. EACH PIECE SHALL BEAR THE GRACE TRADEMARK OF THE AMERICAN PLYWOOD ASSOCIAT10N. PLYW 000 SHALL HAVE A SPAN RATING CIF 4w4. SECTION 20 0640- MECHANICAL GENERAL i IDENTIF[CAT[ON: ALL EQUIPMENT SHALL 8 I LARALLED WITH A MINIMUM 34N CH HIGH PHENOLIC LABEL CORRESPONDING TO THE SYBOL SHOWN ON THE PLANS. 2 TESTING: ALL PIPING AND SYSTEMS SHALL BE PRESSURE TESTED PER CODE REQUIREMENTS AND TO AT LEAST 1.5 TIMES THE SYSTEMS ALLOWED OPERATING PRESSURE, AS REQUIRED BY CODE, AND IN ACCORDANCE VOTH THE OWNER'S STANDARDS 3. SEISMIC: ALL PIPING, DUCTWORK, AND EQUIPMENT SHALL BE INSTALLED AND BRACED FOR THE SEISMIC CATEGORY FOR THIS PROJECT PER SMACNA "SEISMIC RESTRAINT MANUAL GUIDELINES FOR MECHANICAL SYSTEMS', LATEST EDITION, 4. PROVIE 2 SETS OF SPARE FILTERS FOR ALL UNITS %MTH FILTERS. 5. COMMISSIONING: ALL MECHANICAL SYSTEMS ARE TO BE COMMISSIONED PER CODE REQUIREMENTS THE CONTRACTOR HAS SPECIFIC RESPONSIBILITIES FOR SCHEDULING, COORDINATION, STARTUP, TEST DEVELOPMENT, TESTING AND DOCUMENTATION SECTION 20 05 29 - HANGERS SUPPORTS SLEEVES AND SEALS 1. SEISMIC RESTRAINTS: PROVIDE SEISMIC BRACING FOR EQUIPMENT IN ACCORDANCE VATH -SEISMiC RESTRAINT MANUAL GUIDELINES FOR MECHANICAL SYSTEMS' 2. DUCT sUPPORTS: SHALL BE SPACED ON MAxI?,AOM S FOOT CENTERS EXCEPT WHERE THE DUCT SIZE IS LARGER THAN 24' DIAMETER (OR RECTANGULAR EQUIVALENT, E.G 24X20} HANGERS SHALL $E ON MAXIMUM 6 FOOT CENTERS. SHALL COMPLY WITH SMACNA AND CODE REQUIREMENTS. 3. SECTION 20 05 93 -AIR BALANCING 4. GENERAL: SHALL BE BYA COMPANY SPECIALIZING IN THIS WORK. S. BALANCE: BALANCE SYSTEM TO VALUES SHOWN ON DRAWINGS, PROVIDE WRITTEN REPORT (MINIMUM 3 COPIES) DOCUMENTIN13 UNIT DATA AND ALL 8ALANCING WORK MARK FINAL DAMPER POSITIONS WITH PERMANENT MARKER. 6 CONTRACTOR SHALL COORDINATE AND ASSIST WITH BALANCER TO ALLOW FOR ACCESS TO ALL ITEMS. PROVIDE ADDED BALANCING DAMPERS AND VALVES AS THE ]BALANCER MAY REQUIRE SECTION 200740_ INSULATION 1. DUCTWORK BLANKET FIBERGLASS INSULATION, 0.75 LS PER CUBiC FOOT MINIMUM DENSITY, THERMAL CONDUCTIVITY NO GREATER THAN 0.2S BTU4NlHR-SQ FT -DEGREES F AT 75 DEGREES F WITH FACTORY APPLIED VAPOR PROOF JACKET CONSISTING OF ALUMINUM FOIL COVER WITH OPEN MESH FIBERGLASS REINFORCEMENT, LAMINATED TO UL RATED KRAFT, VAPOR TRANSMISSION RATE SHALL NOT EXCEED 0.45 PERMS 2. DUCT INSULATION INSTALLATION: A. ALL SUPPLY AIR DUCTS SHALL BE INSULATED AND ALL RETURN AIR "{f DUCTS LOCATED OUTSiDE CONDITIONED AREAS SHALL BE INSULATED. B INSULATION THICKNESSES SHALL BE AS FOLLOWS: 1. UNLINED SUPPLY AIR DUCT WITHIN CONDITIONED AREA: 7.0 INCH THICK 2. LINED SUPPLY AIR DUCT WITHIN CONDITIONED AREA: NO INSULATION REQUIRED. 3. UNLINED OR LINED SUPPLY AIR DUCT OUTSIDE CONDITIONED AREA (SUCH AS ABOVE ROOF)- 2 0 INCH THICK. SECTION 23 3100- DUCTWORK SYSTEMS I GENERAL FABRICATE AND INSTALL DUCTWORK IN ACCORDANCE WITH SMACNA DUCT CONSTRUCTION PUBLICATIONS AND ASHRAE HANDBOOKS. MATERIALS AND INSTALL.A71ONS SHALL COMPLY WWiTH NFPA 50A, NFPA 908, AND THE IMG. 2 DUCT SIZES: ALL DUCT SIZES ARE INSIDE CLEAR DIMENSIONS. WHERE INSIDE DUCT LINING IS SHOWN, DUCT 01MENSIONS ARE TO THE; INSIDE FACE OF LiNING 3 DUCT PRESSURE CLASS: A SUPPLY OUCTWIQDRK UPSTREAM OF VAV BOXES: +10' W.G B. SUPPLY DUCTMRKDOVMSTREAM OF VAV BOXES, AND OTHER SUPPLY DUCTWORK +2' WG_ C. EXHAUST AND RETURN DUCTWORK: -2' W.G 4 CONSTRUCT OF GALVANIZED SHEET STEEL. SUITABLE FOR LOCK FORMING WTHOUT FLAKING OR CRACKING, CONFORMING TO ASTM A527. HAVING A ZINC COATING OF U 90 F I G OUNCES TOTAL PER SQUARE FOOT FOR BOTH SiDES OF A SHEET, CORRESPONDING TO COATING DESIGNATION 090 PER ASTM A525. DUCT GAUGE. REINFORCEMENT, JOINTS. SEAMS AND CONNECTIONS SHALL BE AS SHOWN iN SMACNA HVAC DUCT CONSTRUCTION STANDARDS ACCORDING TO THE PRESSURE CLASSIFICATION OF THE SYSTEM AND THE DUCT DIMENSIONS. 5. DUCT LINING: FLEXIBLE, INORGANIC GLASS FIBER MATERIAL, MAXIMUio1 THERMAL CONDUCTIVITY OF 0.26 8TU-INCHfHR-SQ.FT.-DEGREES FAT 75 DEGREES F, COATED TQ PREVENT EROSION, AND CONFORMING TO SMACNA DUCT LINER APPLICATION STANDARD. LINING SHALL BE 1 -INCH THICK ADHESIVE, FASTENERS, AND INSTALLATION SHALL BE IN ACCORDANCE WITH SMACNA APPLICABLE STANDARDS S. EXHAUST DUCTS. ROUND EXHAUST DUCT MAY HAVE SPIRAL LOCKSTREAM OR BUTT -WELDED LONGITUDINAL SEAM CONSTRUCTION. CONNECTIONS SHALL BE WELDED: USING SLiP-TYPE OR FLANGED CONNECTIONS FOR DUCT SIZES LESS THAN 36 DIAMETER, AND FLANGED CONNECTIONS FOR LARGER DUCT SIZES. WELD SPACING AT FLANGES SHALL MATCH SMACNA REiNFORCEMENT TABLE REQUIREMENTS. BUT IN NO CASE BE LESS THAN V LONG ON 10` CENTERS. FLANGE SIZES SHALL BE PER SMACNA REQUIREMENTS. FITTINGS SHALL BE FULLY WELDED: WiTH ELBOWS HAVING 1-112' DUCT DIAMETER RADIUS 7. SUPPLY DUCTS: SHALL BE PER SMACNA STANDARDS FOR PRESSURE CLASS CITED. ROUND LINED DUCT SHALL CONSIST OF i -INCH ACOUSTIC INSULATION IN-BETWEEN A PERFORATED INTERIOR DUCT LiNER AND SOLID MAINTAIN POSITIVE CONCENTRICITY OF LINER WITH DUCT. INSULATION SHALL HAVE A M (MUM THERMAL CONOUCTIVITY OF 0.2$ BTU-iNCHfHR-SQ. FT. -DEGREES F AT 75 DEGREES F. UNITED-MCGILL UNITED SHEET METAL'ACOUSTt-K27 OR APPROVED. 8. MANUAL DAMPERS: SHALL BE FABRICATED OF GALVANIZED STEEL, TWO GAUGES HEAVIER THAN DUCT IN WHICH iNSTALLF0_ REGULATOR SETS SHALL HAVE QUADRANT DiAL REGULATOR WITH LOCKING NUT, SQUARE END BEARING ONE SIDE, AND SPRING OR ROUND END BEARING OTHER SIDE. 8. ACCESS DOORS: DOUBLE WALL, MINIMUM 14 GAUGE, HINGED iDR CAMLOCK ACCESS DOOR. DOORS IN INSULATED DUCT SHALL BE INSULATED TYPE. 10. DUCT INSTALLATION: INSTALL ALL DUCTWVQRK IN SIZES AND LOCATIONS AS SHOVW ON THE DRAWINGS. COMPLETE WITH ALL ACCESSORIES AND CONNECTIONS TO PROVIDE COMPLETE AND OPERABLE HEATING. VENTILATING, AIR COND)TIONING, AND EXHAUST SYSTEMS. DUCT SHALL BE INSTALLED LEVEL AND IN NEAT LINES WiTH THE BUILDING CONSTRUCTION. ALL DUCTS ARE TO BE INSTALLED CONCEALED UNLESS INDICATED OTHERWISE 11. DUCT SEALING: SEAL ALL JOINTS iN ACCORDANCE WITH SEAL CLASSIFICATION AS SHOWN IN SMACNAHVAC DUCT CONSTRUCTION STANDARDS. IN ADDITION TO APPLYING, SEALANT TO JOINTS IN ACCORDANCE WITH THE SMACNA REQUIREMENTS, ALL JOINTS AND SEAMS SHALL BE TAPED OVER WITH MINIMUM 34NCHWOE DUCT TAPE SUCH TAPE IS NOT REQUIRED ON EXPOSEO DUCTS, BUT ALL JOINT CORNERS SHALL HAVE ADHESIVE APPLIED. 12. FLEXIBLE DUCT: FACTORY INSULATED FULLY UNED FLEXIBLE DUCT. DUCT SHALL HAVE FULL INTERNAL LINER, REINFORCED WMTH ZINC COATED STEEL HELIX, LINER BONDED TO 1 -INCH THICK FIBERGLASS INSULATION, WITH MAXIMUM CONDUCTIVITY OF 0.26 5TU-INC:H1HRtiSQ FT. -DEGREE F AT 75 DEGREES AND HAVING, A POLYETHYLENE OUTER VAPOR BARRIER. PROVIDE ENDS WITH COMPRESSION CLAMPS FOR POSITiVE CONNECTION TO OVAL OR ROUND FITTINGS, SHALL COMPLY WITH NFPA 90A AND 908 AND SHALL. BE UL LISTED AND LABELED AS A CLASS 1 CONNECTOR PER UL STANDARD 161 FLEXIBLE DUCT SHALL ONLY BE USED AT DIFFUSER CONNECTION, AND SHALL NOT FiXCEED 2 FEET iN LENGTH, IN STRAIGHT RUNS ONLY (UNLESS SPECIFICALLY SHOWN OTHERWISE ON GLANS). DUCT PRESSURE RATINGS SHALL MATCH PRESSURE CLASS OF DUCT SYSTEM INSTALLER ON SECTION 25 0500 - CONTROLS 1. GENERAL: CONTROLS PROVIDER SHALL BE SIEMENS REMOVE EXISTING CONTROLS FROM DEMOLISHED UNIT. PROVIDE NEW CONTROLS FOR NEW UNIT, SAME CONTROL SEQUENCE AS EXISTING. PROVIDE ALL DOCUMENTATION OF START-UP INCLUDING POINT TO POiNT CHECKOUT SHEETS, UPDATED SEQUENCE OF OPERATION, AND UPDATED AS -BUILT DRAWINGS. SECTION 26 0540 - ELECTRICAL 1 GENERAL: ALL ELECTRICAL WORK SHALL BP PERFORMED BY WORKERS SKILLED IN THE ELECTRICAL TRADES, AND SHALL COMPLY WITH NEC AND LOCAL CODES. NOT ALL REQUIRED MATERIALS ARE SPECIFIED HEREIN OR NOTED ON THE PLANS, BUT ALL NEEDED ITEMS SHALL BE PROVIDED TO HAVE COMPLETE AND FUNCTIONING MEDICAL GAS ALARM SYSTEMS, POWER SERVICE TO TANK PAD, AND CYLINDER STORAGE ROOM LIGHTING. 2 RACEWAY: SHALL BE GALVANIZED RIGID STEEL (GRS) OR GALVANIZED FLEXIBLE STi F_L TYPE. SHALL BE INSTALLER CONCF-ALE0 EXCEPT WHERE SPECIFICALLY NOTEDAS EXPOSED RACEWAYS INSTALLED AS DIRECT BURY SHALL HAVE 15 MIL PVC COATING 3. COPPER, 600 VOLT, TYPE THW, THMI THHN OR XH14W1 WIRE MAYBE UTILIZED AT CONTRACTOR OPTION, SUBJECT TO CODE REQUIREMENTS. MINIMUM WIRE SIZE IS 12 AWG FOR POWER AND LIGHTING CIRCUITS 4, JUNCTION BOXES: SHALL BE CONSTRUCTED OF ZINC COATED STEEL, FOUR INCH SIZE MINIMUM, TYPE TO SUIT APPLICATION. S. DISCONNECTS: SHALL BE HEAVY DUTY, SINGLE THROW, LOCKABLE TYPE, HAVING DOOR INTERLOCK (TO PREVENT OPENING WHEN ENERGIZED), ENCLOSURE TO SUITE ENVIRONMENT REVIEWED FOR CODE COMPLIANCE APPROVED SEP 2 2 2016 City of Tukwila BUILDING DIVISION WSW Iigoomp i zo 2 m Rl a 11 9 F-CEIVED CIT OF TUKWILA Ptip 10ENT2 2016 M 1T ER 10 u I t OAS HEAT/ELECTRIC COOLING UNIT SCHEDULE SPECIFIED COOLING CAP.- HEATING CAP " _ SUPPLY FAN COMPRESSOR GOND. FAN COMB. FAN POWER EXHAUST FAN FILTERS MAS` MIN UNIT ELECTRICAL cl e SYMBOL MANUFACTURER AND NUMBER AREA SERVED �. __. - ----- ------.-• ---- -�� � to WEIGHT OAREMARKS.SERIES . CL O '2�pl -------- ---- j I MQH MBH EFF MSH f UE CFM ESP HP QTY RLA (E,A) O -r^ FLA (EA) PTY HP IEA) CFM ESP HP TYPE MiN SIZE LBS MCA MFS VOLTSiPH HVAC -i YORIVJCI V54AS54 MAIN OFFICE 475 8 475 8 EE'R 533 _ 426 4 80% 16,0(?0 2.51, 25 a 16.7 4 2 9 1 0.6 - 0.5" 7.5 } 11 SF 6,450 3300 132 150 48013 SEE NOTES BELOW ai 1.; I I SIGNE6 �4�43-2618 r= { L1J .�1 f Cil l =4 rz .i, 2Z it CI ZW 7'G d uj W(f) 1 W . c1 MERV 11 Q I �.r y m''.' ' COOLING CAPACITY IS AR.1 RATING: AT 80" F DB; 67° F WB INDOOR NOTES 1 PROVIDE ALL. UNITS WITH 0.100% LDA ECONOMIZER. DISCONNECT CUBES. 4 WEIGHT INCLUDES UNIT CURES 8 ACCESSORIES 8 SHALL NOT SEE EXCEEDED. COIL EAT, 95'F OUTDOOR COiL EAT, AND ARI NOMINAL CFM RELIEF AIR CAPABILITY, HINGED ACCESS DOORS, 9 SMOKE DETECTOR. 5. WITH CUSTOM OFFSET CURB ADAPTOR. 2 ALL UNITS SHALL USE R4 10A OR R407C REFRIGERANT (UNC}). RATED IN ACCORDANCE WITH ANSI IIID DOE STANDARDS 5. WITH DDC SYSTEM CONTROL INTERFACE, AND RA, SA, AND OA TEMPERATURE SENSORS 3 UNIT CAPACITIES SHALL BE WITHIN 5% OF THOSE SCHEDULED. 7. SINGLE POINT POWER WITH DISCONNECT AND CONVENIENCE OUTLET. mr ROJ E OT PSE C I F ICIAATlOr4b 1. SECTION 23 1123 -GAS PIPING 2 STEEL PIPE FITTINGS. A THREADED FiTTLNGS• MALLEABLE IRON PER ASME B18 3- CAST IRON PER ASME 816.4. 3 GAS PIPING: SCHEDULE 40 STEEL PIPING {COMPLYING VMTH ASME A53} Wr~dTH THREADED CLASS 125 FITTINGS. 4. ZUL LISTED FOR GAS SERVICE. BRONZE TWO-PIECE BLOWOUT PROOF STEM, FULL PORT. NIBCO T -685 -70 -UL. 5. RATED AT MINIMUM 125 PSIG AT 200 DEGREES F; PROVIDE DIELECTRIC UNIONS WHERE DISSIMILAR METALS JOIN. PROVIDE UNIONS AT CONNECTIONS TO ALL EQUIPMENT 6. INSTALLATION: FOLLOW ESTABLISHED PROFESSIONAL PRACTICES FOR JOINING OF PIPING AND STT AS TO SUIT THE SYSTEM PRESSURES AND TEMPERATURES INVOLVED. 7. SECTION 23 81 53 - HVAC UNITS 8. HVAC UNITS ROOFTOP PACKAGED GAS HEAT ELECTERiC COOL ROOFTOP UNIT$ WITH AS A MINIMUM SCHEDULES CAPACITY. SEE SCHEDULE FOR ACCESSORIES MANUFACTURER AND MODELAS SCHEDULED. 9. PROVIDE WiTH 0-100% OA ECONOMIZER AND CUSTOM ROOF ADAPTOR CURB ENERMY COBE. - HVAC 1 LOAD CALCULATIONS HAVE BEEN PERFORMED IN ACCORDANCE WITH WSEC C4032.1..OR EQUIPMENT IS SELECTED AT SAME CAPACITY AS THE UNIT BEING REPLACED. 2 EQUIPMENT HAS BEEN SELECTSI3 PER WSEC 0403.2.2 3 VENTILATION AND THE ABILITY TO REDUCE OUTSIDE AIR TO IMG MINIMUM$ SHALL BE PROViDED PER WSEC 0403 2 5. 4 MOTORS i HP AND LARGER SHALL BE ENERGY EFFICIENT TYPE PER VVSEC C403.2.13: MOTORS 1112 HP TO 1 HP SHALL BE EiCM *TYPE OR MEET L41NIMUM EFFICIENCY REQUIREMENTS PER WSEC C403.2.10.3. S. TEMPERATURE CONTROL SYSTEM SHALL HAVE A MINIMUM DEAD BAND OF 5 DEGREES AS REQUIRED BY WSEC 0403.2.4.2. 6. HVAC SYSTEMS SHALL BE EQUIPPED VIATH AUTOMATIC CONTROLS CAPABLE OF PROVIDING NIGHT SETBACK. SEVEN DIFFERENT DAILY SCHEDULES, AND OPTIMUM START PER THE REQUIREMENTS OF WNSEC C403.2 4.3 7 OUTSIDE AIR INTAKES, EXHAUST OUTLETS, AND RELIEF OUTLETS SHALL BE PROVIDEDWMTH DAMPERS THAT COMPLY WITH WSEC C403.2.4.4. DAMPER SHALL AUTOMATLCALLY CLOSE VVI-IEN SYSTEM OR SPACES SERVED ARE NOT IN USE OR DURING WARM-UP. COOL4)OWN, AND SETBACK DAMPER MAXIMUM LEAKAGE RATE SHALL NOT EXCEED MAXiMUM ALLOWED BYVVSf:C 0402.4.52 a COMBUSTION HEATING EQUIPMENT WITH A CAPACITY OVER 225 MBH SHALL HAVE MODULATING OR STAGED COMBUSTION CONTROL PER WSEC C+403.Z4.6. 9. FAN SYSTEMS SERVING A ZONE OR MULTIPLE ZONES WViTHOUT SEPARATING WALLS WMTH TOTAL AIRFLOVV OVER 10,E: W CFM SHALL REDUCE AIRFLOWWi BASED ON SPAC E HEATING AND COOLING DEMAND PER WSEC 0403.2.122 10. ALL DUCTIM(3RK SHALL BE CONSTRUCTED AND SEALED IN ACCORDANCE VATH IMC, MEC C402 AND LSC REQUIREMENTS PER MEC C403.2.7. 11 DUCTS AND PLENUMS DESIGNED TO OPERATE AT A PRESSURE ABOVE 3' W.C. SHALL BE LEAK TESTED PER WNSSC 0403.2 7.3.3. DOCUMENT AND SUBMIT TEST RESULTS TO THE AHJ AS REQUIRED 12. DUCTWORK SHALL BE INSULATED TO THE APPROPRIATE R -VALUE AS REQUIRED BYyti EC 0403.2 7. 13 PROVIDE HIGH LIMiT SHUT-OFF CONTROL OF ECONOiySIZER COOLING PER TABLE C403.3.1.1.3(2) 14 ECONOMIZER DAMPERS SHALL BE CAPABLE OF BEING SEQUENCED WITH MECHANICAL COOLING EQUIPMENT. ECONOMIZERS ON SYSTEMS WViTH COOLING CAPACITY GREATER THAN 65 MBH SHALL BE CAPABLE OF PROVIDING PARTIAL COOLING PER MEC 0403.3.1.1.2 15. ECONOMIZER CONTROLS SHALL BE SUCH THAT ECONOMIZER OPERATION DOES NOT INCREASE BUILDING HEATING ENERGY DURING NORMAL OPERATIONS PER WSEC C403,4.1.4, AND SHALL BE INTEGRATED WITH MECHANICAL COOLING SYSTEM AND BE CAPABLE OF PROVIDING PARTIAL COOLING PER WSEC 0403.4.1.3 16. FORVAV SYSTEMS WITH ODD, PROVIDE STATIC PRESSURE RESET PER VWSEC 0403.4.2.2 17. SUPPLY ALR SYSTEMS SERVING MULTIPLE ZONES SHALL BE VAV TYPE DESIGNED AND CAPABLE OF $EING CONTROLLED TO REDUCE PRIMARY AiR SUPPLY TO EACH ZONE TO A MAXIMUM FLOW RATE AS ALLOWED BY WSEC 0403 4 5. IS. HVAC SYSTEMS NTH MULTIPLE ZONES SHALL REQUIRE TEMPERATURE RESET CONTROLS MICH AUTOMATICALLY RESET SUPPLY AIR TEMPERATURES PER WSEC 0403.4.5.4. 19. COOLING SYSTEMS SHALL. NOT USE HOT GAS BYPASS OR OTHER EVAPORATOR PRESSURE CONTROL SYSTEMS UNLESS THERE ARE MULTIPLE STEPS OF UNLOADING, HOT GAS BYPASS CAPACITY SHALL BE LIMITED PER TABLE 0403.4.7. DOES NOT APPLY TO UNITARY PACKAGED SYSTEMS 90 MBH OR SMALLER 20. AIR SHALL BE BALANCED AS REQUIRED IN SECTION 0408 2.21 AND C408.2.2 2 OF THE WSEC 21. PROVIDE COMMISSIONING PLAN 8 REPORT REQUIREMENTS FOR PRELIMINARY MID FiNAL COMMISSION048 PER SECTION C408.1. PROVIDE SECiLIENCE OF OPERATIONS AND TEST PROCEi3URES PER SECTION C•4U6.1.2 AND SUBMIT COMPLIANCE CHECKLIST PER SECTION 0108.1 3 4 OF THE WSEC TO THE BUILDING OFFICiAL UPON SUBSTANTIAL COMPLETION. 22. THESE'ENERGY CODE NOTES' ARE LiSTED TO SATISFY THE BUILDING DEPARTMENTS REQUIREMENT THAT CERTAIN INFORMATION BE PLACED ON THE PIANS, BUT DO NOT DIMINISH THE FULL PROJECT REQUIREMENTS PROVIDE ITEMS IN EXCESS OF CODE WHERE NOTED ON DRAWINGS AND IN SPECIFICATIONS. FOR OTHER ADDED REQUIREMENTS, SEE SPECIFICATIONS. SECTION 010000 -GENERAL 1. CODE CCMPLIANCE- ALL WORK SHALL COMPLY WITH ALL LOCAL CODES AND ORDINANCES 2 DRAW NGS. DRAW NGS ARE DIAGRAMMATIC AND SHOWN THE GENERAL ARRANGEMENT OF THE CONSTRUCTION, AND THEREFORE DO NOT SHOW ALL NECESSARY OFFSETS, FITTINGS, ALTERATIONS TO EXISTING ITEMS, AND ACCESSORIES WHICH ARE REQUIRED TO FORM COMPLETE AND OPERABLE SYSTEMS. 3 FIELD VERIFICATION: THE CONTRACTOR SHALL BE RESPONSIBLE FOR CHECKING FIELD CONDITIONS AND VERIFYING ALL MEASUREMENTS AND RELATIONSHIPS INDICATED ON THE DRAWINGS BEFORE SUBMITTING BIDS AND AGAIN BEFORE PROCEEDING WITH THE WORK 4. NOTiFY THE ARCH ITECT1ENGINEER OF ANY CiISCREPANCIES OR CONFLICTS BEFORE PROCEEDING WITH ANY MRK OR THE PURCHASING OF ANY MATERIALS FOR THE ARENS) OF CONFLICT UNTIL REQUESTING AND OBTAINING VVR ITTEN INSTRUCTIONS FROM THE ARCHITECTIENGINEER ON HOWTO PROCEED. WHERE CONFLICTS OCCUR, THE MOST EXPENSIVE AND STRINGENT REQUIREMENT(AS JUDGED BYTHE ARCHiTEICTIENGiNEER) SHALL PREVAIL. ANY WORKDONE AFTER DiSC,0VERY OF SUCH DISCREPANCIES OR CONFLICTS AND PRIOR TO OBTAINING THE ARCHITECTIENGINEER'S INSTRUCTIONS ON HOW TO PROCEED SHALL BE DONE AT THE CONTRACTOR'S EXPENSE. 5 DRAVWiNGS AND SPECIFICATIONS. DRAWINGS AND SPECIFICATIONS ARE COMPLEMENTARY AND WHAT IS CALLED FOR IN EITHER IS BINDING AS IF CALLED FOR IN BOTH. THE DRAWINGS ARE DIAGRAMMATIC AND SHOWTHe OENeRAL ARRANGEMENT OF THE CONSTRUCTION AND THEREFORE DO NOT SHOWALL- OFFSETS, FITTINGS AND ACCESSORIES MICH ARE REQUIRED TO FORM A COMPLETE AND OPERATING INSTALLATION. MECHANICAL WORK IS SHOWN ON MULTIPLE DRAWNNOS AND IS NOT LIMITED TO A PARTICULAR SET OF SHEETS, OR SHEETS PREFACED VOTH A PARTICULAR LETTER. 6. PERMITS AND FEES: THE CONTRACTOR SHALL OBTAIN AND PAY FOR ALL PERMITS. LICENSES, FEES AND INSPECTIONS AS REQUIRED 6Y THE GOVERNING CODES AND AS SPECIFIED HEREIN. 7. SUBMITTALS: CONTRACTOR SHALL SUBMIT SHOP DRAWW INGS FOR ALL PRODUCTS PROPOSED TO BE USED ON THIS PROJECT FOR OWNER REVIIEW- PRODUCTS SHALL NOT BE USED UNTIL APPROVED BY THE OVWMER OR HIS REPRESENTATIVE. SUBMIT 3 COPIES PLUS ANYADVITiONALQUANTITIES THE CONTRACTOR NEEDS (3 COPIES %MLL BE RETAINED BY THE OWNER). 6 RECORD DRAWINGS: THE CONTRACTOR SHALL MAINTAIN A SET OF CONTRACT PLANS AT THE PROJECT SITE UPON WHICH ALL CHANGES FROM THE AS -BID PLANS ARE NOTED. AT THE. COMPLETION OF THE PROJECT, THE CONTRACTOR SHALL DELIVER TO THE OWNER ONE COMPLETE SET OF THESE RECORD DRAWINGS. 9. PROTECTION: CONTRACTOR IS RESPONSIBLE FOR PROTECTION OF ALL MATERIAL, FOUIPMENTANDAPPARATUS PROVIDED UNDER THIS SECTION FROM DAMAGE. WATER, CORROSION, FREEZING AND DUST, BOTH IN STORAGE AND WHEN INSTALLEO, UNTIL FINAL PROJECT ACCEPTANCE 10 COORDINATION THE CONTRACTOR SHALL COORDINATE ALL CONSTRUCTION ACTIVITIES WITH THE OWNER AND COOPERATE FULLY SO AS TO MINIMIZE CONFLICTSAND TO ALLOW FULL OWNER USAGE (UNLESS INDICATED OTHERWIWiSE) OF ALL AREAS DURING CONSTRUCTION 11. CUTTING AND PATCHING: SHALL BE DONE BY SKILLED LA13OR EXPERIENCED IN PROVIDING OPENINGS AND PATCHING OF THE MATERIALS INVOLVED. AREAS SHALL BE PATCHEDAND RESTORED TO AFiNISHEO CONDITION, EQUAL TO ADJACENT FINAL FINISHED AREAS THAT HAVE NOT BEEN CUT 12. PAINTING: SHALL BE PROVIDEO VMERE INDICATED, BY SKILLED PAINTERS IN CONFORMANCE WITH STANDARD PROFESSIONAL PRACTICE INCLUDING CLEANING AND PRIMING OF MATERIALS TO BE PAINTED. COLORS SHALL BE SELECTED BY THE OWNER 13. FINAL INSPECTION: PRIOR TO ACCEPTANCE OF THEWORK THE CONTRACTOR SHALL PUT ALL SYSTEMS INTOOPERATION FORA PRRIOD OF NOT LESS THAN S WORKING DAYS 60 THAT THEY MAY BE INSPECTED BY THE OVWER. 14 INSTRUCTION! O S M MANUALS: DURING THE FINAL iNSPECTION PERIOD, THE CON7RAC70R SHALL PROVIDE INSTRUCTIONS AND DEMONSTRATIONS FOR THE OWNER'S REPRESENTATIVES ON THE OPERATION AND MAINTENANCE OF ALL EQUIPMENT, AND PROVIDE 3 SETS OF O&M MANUALS. O d M MANUAL SHALL INCLUDE CONTACT INFORMATION FOR CONTRACTOR AND MAJOR EQUIPMENT SUPPLIERS. INCLUDE A COPY OF THE PRODUCT SUBMITTAL DATAFOR ALL MAJOR EQUIPMENT ITEMS WITH THE 0 Iii M DATA. INCLUDE SPACE FOR REDUCED SIZE AS -BUILT DRAWINGS 15 WARRANTY: ALL WORK ANO EQUIPMENT SHALL BE WARRANTED TO BE. FREE FROM DEFECTS AND CAPABLE OF PROVIDING SATISFACTORY OPERATION FOR A PERIOD OF ONE YEAR AFTER FINAL ACCEPTANCE: 16 NEVWtMATERIALS: ALL ITEMS ARE NEW UNLESS SPECIFICALLY NOTED AS ENST'ING 17. COMPLETE SYSTEMS: NOT ALL NECESSARY MATERIALS TO PERFORM T89 WORK REQUiRED ARE SPECIFIED OR SHOWN- CONTRACTOR SHALL, PROVIDE ALL ITEMS NEEDED TO HAVE COMPLETED PROPERLY OPERATING SYSTEMS, ITEMS PROVIDED SHALL BE OF COiyAMERCIAL ANSTITUTiONAL QUALITY, CONSISTENT WiTH THE QUALITY OF RELATED ITEMiS PROVIDED ON THE PROJECT OR CURRENTLY BEING USED IN THE BUILDING. IS OFFSETS AND FITTINGS INCLUDE IN BILI ALL NECESSARY FITTINGS AND OFFSET TO COMPLETELY CONNECT UP ALL SYSTEMS, MAINTAIN CLEAR ACCESS PATHS TO EQUIPMENT, AND COMPLY WiTH ALL PROJECT REQUIREMENTS. OFFSETS ARE REQUIRED TO ROUTE. AROUND BUILDING STRUCTURAL ELEMENTS. ROOF SLOPES, MECHANICAL SYSTEMS, ELECTRICAL SYSTEMS, AND NUMEROUS OTHER ITEMS. DUE TO THE SCHEMATIC NATURE OF THE FLANS $UGH OFFSETS ARE TYPICALLY NOT SHOWN. CONTRACTOR IS RESPONSIBLE TO DETERMINE THE QUANTITY OF OFFSETS AND FITTINGS REQUIRED. AND THE LABOR INVOLVED. NO ADDED PAYMENT OR'EICTRAS' WILL BE GRANTED FOR THE CONTRACTOR'S FAILURE TO CORRECTLY ESTIMATE THE NUMBER OF OFFSETS AND FITTINGS AND LABOR REQUIRED. CONTRACTOR IS ADVISED THAT EQUIPMENT AND CONNECTIONS MAY REQUIRE MORE OFFSETS AND TRANSITIONS 19 CONTRACTOR LAY -OUT: THE CONTRACTOR IS REQUIRED TO DO FURTHER LAYOUT TO FINALIZE THE DESIGN SHOtM+1 ON THE PROJECT DRAWINGS. SUCH MRK INCLUDES FIELD INVESTIGATION OF ALL EXISTING CONDITIONS, LAYOUT SKETCHES TO VERIFY RISES AND ORCIPS IN PIPING AND DUCTWORK, COORDINATiON. OF ELEVATIONS %NITH OTHER TRADES, AND NOTIFYING OTHER TRADES OF ITEMS TO BE RELOCATED. ETC. 20. ALL ITEMS REQUIRING MAINTENANCE SHALL BE ARRANGED TO BE ACCESSIBLE A I B I E GE E TIONS SECTION 02 00 DO - SITEVMRK I. SITE CLEARING: CLEAR SITE AS NEEDED FOR NEW TRENCHING AND PAO INSTALLATION. DISPOSE OF ALL MATERIAL OFF SITE. PROVIDE PROTECTION OF AOJACENTAREA4S FROM DUSTIDIRTINOISEIEROSiON AND OTHERADVERSE AFFECTS DUE TO CONSTRUCTION. REPAIR ALL DISTURBED AREAS TO RE -CONSTRUCTION CONDITION OR BETTER. SECTION 06 10 00- ROUGH CARPENTRY 1. FRAMING AND TREATED LUMBER: DOUG-FIRILARCH NO- 2OR HEM -FIR NO.1 OR BETTER, MINIMUM F=1200 PSI (SINGLE USE). CONFIRM TO WEST COAST LUMBER INSPECTION 8UREAL UB OR WE WOOD (WCUB) PRODUCTS ASSOCIATiflN (VWMtPA). EACH PIECE OF LUMBER SHALL BEAR THE VVCLIS OR ~A GRADE TRADEMARK 2 FRAMING CONNECTORS AND BRIDGING: SHALL BE [.C.B.O. APPROVED AND SHALL BE MANUFACTURED BY SIMPSON OR BOWMAN OR APPROVED EQUAL, FURNISHED COMPLETE WITH ANY SPECIAL NAILS REQUIRED ALL FRAMING CONNECTORS SHALL. BE HOT -DIPPED GALVANIZED. 3. ROUGH HARDWARE' PROVIDE ROUGH HARDWARE OF THE TYPE AND SIZE NECESSARY FOR THE PROJECT REQUIREMENTS. SIZES. TYPES, AND SPACING OF FASTENINGS OF MANUFACTURED BUILDING MATERIALS SHALL SE AS RECOMMENDED BY THE PRODUCT MANUFACTURER UNLESS OTHERWISE INDICATED OR SPECIFIED. 4. PLYWOOD. GROUP 1 OR GROUP 2 SPECIES, C -D GRADE EXPOSURE 1 CONFORMING TO PS 1-83. EACH PIECE SHALL BEAR THE GRACE TRADEMARK OF THE AMERICAN PLYWOOD ASSOCIAT10N. PLYW 000 SHALL HAVE A SPAN RATING CIF 4w4. SECTION 20 0640- MECHANICAL GENERAL i IDENTIF[CAT[ON: ALL EQUIPMENT SHALL 8 I LARALLED WITH A MINIMUM 34N CH HIGH PHENOLIC LABEL CORRESPONDING TO THE SYBOL SHOWN ON THE PLANS. 2 TESTING: ALL PIPING AND SYSTEMS SHALL BE PRESSURE TESTED PER CODE REQUIREMENTS AND TO AT LEAST 1.5 TIMES THE SYSTEMS ALLOWED OPERATING PRESSURE, AS REQUIRED BY CODE, AND IN ACCORDANCE VOTH THE OWNER'S STANDARDS 3. SEISMIC: ALL PIPING, DUCTWORK, AND EQUIPMENT SHALL BE INSTALLED AND BRACED FOR THE SEISMIC CATEGORY FOR THIS PROJECT PER SMACNA "SEISMIC RESTRAINT MANUAL GUIDELINES FOR MECHANICAL SYSTEMS', LATEST EDITION, 4. PROVIE 2 SETS OF SPARE FILTERS FOR ALL UNITS %MTH FILTERS. 5. COMMISSIONING: ALL MECHANICAL SYSTEMS ARE TO BE COMMISSIONED PER CODE REQUIREMENTS THE CONTRACTOR HAS SPECIFIC RESPONSIBILITIES FOR SCHEDULING, COORDINATION, STARTUP, TEST DEVELOPMENT, TESTING AND DOCUMENTATION SECTION 20 05 29 - HANGERS SUPPORTS SLEEVES AND SEALS 1. SEISMIC RESTRAINTS: PROVIDE SEISMIC BRACING FOR EQUIPMENT IN ACCORDANCE VATH -SEISMiC RESTRAINT MANUAL GUIDELINES FOR MECHANICAL SYSTEMS' 2. DUCT sUPPORTS: SHALL BE SPACED ON MAxI?,AOM S FOOT CENTERS EXCEPT WHERE THE DUCT SIZE IS LARGER THAN 24' DIAMETER (OR RECTANGULAR EQUIVALENT, E.G 24X20} HANGERS SHALL $E ON MAXIMUM 6 FOOT CENTERS. SHALL COMPLY WITH SMACNA AND CODE REQUIREMENTS. 3. SECTION 20 05 93 -AIR BALANCING 4. GENERAL: SHALL BE BYA COMPANY SPECIALIZING IN THIS WORK. S. BALANCE: BALANCE SYSTEM TO VALUES SHOWN ON DRAWINGS, PROVIDE WRITTEN REPORT (MINIMUM 3 COPIES) DOCUMENTIN13 UNIT DATA AND ALL 8ALANCING WORK MARK FINAL DAMPER POSITIONS WITH PERMANENT MARKER. 6 CONTRACTOR SHALL COORDINATE AND ASSIST WITH BALANCER TO ALLOW FOR ACCESS TO ALL ITEMS. PROVIDE ADDED BALANCING DAMPERS AND VALVES AS THE ]BALANCER MAY REQUIRE SECTION 200740_ INSULATION 1. DUCTWORK BLANKET FIBERGLASS INSULATION, 0.75 LS PER CUBiC FOOT MINIMUM DENSITY, THERMAL CONDUCTIVITY NO GREATER THAN 0.2S BTU4NlHR-SQ FT -DEGREES F AT 75 DEGREES F WITH FACTORY APPLIED VAPOR PROOF JACKET CONSISTING OF ALUMINUM FOIL COVER WITH OPEN MESH FIBERGLASS REINFORCEMENT, LAMINATED TO UL RATED KRAFT, VAPOR TRANSMISSION RATE SHALL NOT EXCEED 0.45 PERMS 2. DUCT INSULATION INSTALLATION: A. ALL SUPPLY AIR DUCTS SHALL BE INSULATED AND ALL RETURN AIR "{f DUCTS LOCATED OUTSiDE CONDITIONED AREAS SHALL BE INSULATED. B INSULATION THICKNESSES SHALL BE AS FOLLOWS: 1. UNLINED SUPPLY AIR DUCT WITHIN CONDITIONED AREA: 7.0 INCH THICK 2. LINED SUPPLY AIR DUCT WITHIN CONDITIONED AREA: NO INSULATION REQUIRED. 3. UNLINED OR LINED SUPPLY AIR DUCT OUTSIDE CONDITIONED AREA (SUCH AS ABOVE ROOF)- 2 0 INCH THICK. SECTION 23 3100- DUCTWORK SYSTEMS I GENERAL FABRICATE AND INSTALL DUCTWORK IN ACCORDANCE WITH SMACNA DUCT CONSTRUCTION PUBLICATIONS AND ASHRAE HANDBOOKS. MATERIALS AND INSTALL.A71ONS SHALL COMPLY WWiTH NFPA 50A, NFPA 908, AND THE IMG. 2 DUCT SIZES: ALL DUCT SIZES ARE INSIDE CLEAR DIMENSIONS. WHERE INSIDE DUCT LINING IS SHOWN, DUCT 01MENSIONS ARE TO THE; INSIDE FACE OF LiNING 3 DUCT PRESSURE CLASS: A SUPPLY OUCTWIQDRK UPSTREAM OF VAV BOXES: +10' W.G B. SUPPLY DUCTMRKDOVMSTREAM OF VAV BOXES, AND OTHER SUPPLY DUCTWORK +2' WG_ C. EXHAUST AND RETURN DUCTWORK: -2' W.G 4 CONSTRUCT OF GALVANIZED SHEET STEEL. SUITABLE FOR LOCK FORMING WTHOUT FLAKING OR CRACKING, CONFORMING TO ASTM A527. HAVING A ZINC COATING OF U 90 F I G OUNCES TOTAL PER SQUARE FOOT FOR BOTH SiDES OF A SHEET, CORRESPONDING TO COATING DESIGNATION 090 PER ASTM A525. DUCT GAUGE. REINFORCEMENT, JOINTS. SEAMS AND CONNECTIONS SHALL BE AS SHOWN iN SMACNA HVAC DUCT CONSTRUCTION STANDARDS ACCORDING TO THE PRESSURE CLASSIFICATION OF THE SYSTEM AND THE DUCT DIMENSIONS. 5. DUCT LINING: FLEXIBLE, INORGANIC GLASS FIBER MATERIAL, MAXIMUio1 THERMAL CONDUCTIVITY OF 0.26 8TU-INCHfHR-SQ.FT.-DEGREES FAT 75 DEGREES F, COATED TQ PREVENT EROSION, AND CONFORMING TO SMACNA DUCT LINER APPLICATION STANDARD. LINING SHALL BE 1 -INCH THICK ADHESIVE, FASTENERS, AND INSTALLATION SHALL BE IN ACCORDANCE WITH SMACNA APPLICABLE STANDARDS S. EXHAUST DUCTS. ROUND EXHAUST DUCT MAY HAVE SPIRAL LOCKSTREAM OR BUTT -WELDED LONGITUDINAL SEAM CONSTRUCTION. CONNECTIONS SHALL BE WELDED: USING SLiP-TYPE OR FLANGED CONNECTIONS FOR DUCT SIZES LESS THAN 36 DIAMETER, AND FLANGED CONNECTIONS FOR LARGER DUCT SIZES. WELD SPACING AT FLANGES SHALL MATCH SMACNA REiNFORCEMENT TABLE REQUIREMENTS. BUT IN NO CASE BE LESS THAN V LONG ON 10` CENTERS. FLANGE SIZES SHALL BE PER SMACNA REQUIREMENTS. FITTINGS SHALL BE FULLY WELDED: WiTH ELBOWS HAVING 1-112' DUCT DIAMETER RADIUS 7. SUPPLY DUCTS: SHALL BE PER SMACNA STANDARDS FOR PRESSURE CLASS CITED. ROUND LINED DUCT SHALL CONSIST OF i -INCH ACOUSTIC INSULATION IN-BETWEEN A PERFORATED INTERIOR DUCT LiNER AND SOLID MAINTAIN POSITIVE CONCENTRICITY OF LINER WITH DUCT. INSULATION SHALL HAVE A M (MUM THERMAL CONOUCTIVITY OF 0.2$ BTU-iNCHfHR-SQ. FT. -DEGREES F AT 75 DEGREES F. UNITED-MCGILL UNITED SHEET METAL'ACOUSTt-K27 OR APPROVED. 8. MANUAL DAMPERS: SHALL BE FABRICATED OF GALVANIZED STEEL, TWO GAUGES HEAVIER THAN DUCT IN WHICH iNSTALLF0_ REGULATOR SETS SHALL HAVE QUADRANT DiAL REGULATOR WITH LOCKING NUT, SQUARE END BEARING ONE SIDE, AND SPRING OR ROUND END BEARING OTHER SIDE. 8. ACCESS DOORS: DOUBLE WALL, MINIMUM 14 GAUGE, HINGED iDR CAMLOCK ACCESS DOOR. DOORS IN INSULATED DUCT SHALL BE INSULATED TYPE. 10. DUCT INSTALLATION: INSTALL ALL DUCTWVQRK IN SIZES AND LOCATIONS AS SHOVW ON THE DRAWINGS. COMPLETE WITH ALL ACCESSORIES AND CONNECTIONS TO PROVIDE COMPLETE AND OPERABLE HEATING. VENTILATING, AIR COND)TIONING, AND EXHAUST SYSTEMS. DUCT SHALL BE INSTALLED LEVEL AND IN NEAT LINES WiTH THE BUILDING CONSTRUCTION. ALL DUCTS ARE TO BE INSTALLED CONCEALED UNLESS INDICATED OTHERWISE 11. DUCT SEALING: SEAL ALL JOINTS iN ACCORDANCE WITH SEAL CLASSIFICATION AS SHOWN IN SMACNAHVAC DUCT CONSTRUCTION STANDARDS. IN ADDITION TO APPLYING, SEALANT TO JOINTS IN ACCORDANCE WITH THE SMACNA REQUIREMENTS, ALL JOINTS AND SEAMS SHALL BE TAPED OVER WITH MINIMUM 34NCHWOE DUCT TAPE SUCH TAPE IS NOT REQUIRED ON EXPOSEO DUCTS, BUT ALL JOINT CORNERS SHALL HAVE ADHESIVE APPLIED. 12. FLEXIBLE DUCT: FACTORY INSULATED FULLY UNED FLEXIBLE DUCT. DUCT SHALL HAVE FULL INTERNAL LINER, REINFORCED WMTH ZINC COATED STEEL HELIX, LINER BONDED TO 1 -INCH THICK FIBERGLASS INSULATION, WITH MAXIMUM CONDUCTIVITY OF 0.26 5TU-INC:H1HRtiSQ FT. -DEGREE F AT 75 DEGREES AND HAVING, A POLYETHYLENE OUTER VAPOR BARRIER. PROVIDE ENDS WITH COMPRESSION CLAMPS FOR POSITiVE CONNECTION TO OVAL OR ROUND FITTINGS, SHALL COMPLY WITH NFPA 90A AND 908 AND SHALL. BE UL LISTED AND LABELED AS A CLASS 1 CONNECTOR PER UL STANDARD 161 FLEXIBLE DUCT SHALL ONLY BE USED AT DIFFUSER CONNECTION, AND SHALL NOT FiXCEED 2 FEET iN LENGTH, IN STRAIGHT RUNS ONLY (UNLESS SPECIFICALLY SHOWN OTHERWISE ON GLANS). DUCT PRESSURE RATINGS SHALL MATCH PRESSURE CLASS OF DUCT SYSTEM INSTALLER ON SECTION 25 0500 - CONTROLS 1. GENERAL: CONTROLS PROVIDER SHALL BE SIEMENS REMOVE EXISTING CONTROLS FROM DEMOLISHED UNIT. PROVIDE NEW CONTROLS FOR NEW UNIT, SAME CONTROL SEQUENCE AS EXISTING. PROVIDE ALL DOCUMENTATION OF START-UP INCLUDING POINT TO POiNT CHECKOUT SHEETS, UPDATED SEQUENCE OF OPERATION, AND UPDATED AS -BUILT DRAWINGS. SECTION 26 0540 - ELECTRICAL 1 GENERAL: ALL ELECTRICAL WORK SHALL BP PERFORMED BY WORKERS SKILLED IN THE ELECTRICAL TRADES, AND SHALL COMPLY WITH NEC AND LOCAL CODES. NOT ALL REQUIRED MATERIALS ARE SPECIFIED HEREIN OR NOTED ON THE PLANS, BUT ALL NEEDED ITEMS SHALL BE PROVIDED TO HAVE COMPLETE AND FUNCTIONING MEDICAL GAS ALARM SYSTEMS, POWER SERVICE TO TANK PAD, AND CYLINDER STORAGE ROOM LIGHTING. 2 RACEWAY: SHALL BE GALVANIZED RIGID STEEL (GRS) OR GALVANIZED FLEXIBLE STi F_L TYPE. SHALL BE INSTALLER CONCF-ALE0 EXCEPT WHERE SPECIFICALLY NOTEDAS EXPOSED RACEWAYS INSTALLED AS DIRECT BURY SHALL HAVE 15 MIL PVC COATING 3. COPPER, 600 VOLT, TYPE THW, THMI THHN OR XH14W1 WIRE MAYBE UTILIZED AT CONTRACTOR OPTION, SUBJECT TO CODE REQUIREMENTS. MINIMUM WIRE SIZE IS 12 AWG FOR POWER AND LIGHTING CIRCUITS 4, JUNCTION BOXES: SHALL BE CONSTRUCTED OF ZINC COATED STEEL, FOUR INCH SIZE MINIMUM, TYPE TO SUIT APPLICATION. S. DISCONNECTS: SHALL BE HEAVY DUTY, SINGLE THROW, LOCKABLE TYPE, HAVING DOOR INTERLOCK (TO PREVENT OPENING WHEN ENERGIZED), ENCLOSURE TO SUITE ENVIRONMENT REVIEWED FOR CODE COMPLIANCE APPROVED SEP 2 2 2016 City of Tukwila BUILDING DIVISION WSW Iigoomp i zo 2 m Rl a 11 9 F-CEIVED CIT OF TUKWILA Ptip 10ENT2 2016 M 1T ER 10 u I t r t1. i I Y •y f cl e L ' '400 to t . CL j I i O 0 C' :D' W (Jwt 00 z'aw-'O a 3� Dow F- wCL M, w z �-- CL IL ' 0 i } 0 ai 1.; I I SIGNE6 �4�43-2618 r= { L1J .�1 f Cil l =4 rz .i, 2Z it CI ZW 7'G d uj W(f) 1 W . c1 F- .- O W W }- Q I �.r y m''.' SHEET SQE 13 TRUE SCALE W-41:4 ABOVE LME MEASURES AS NOTED X J 2 3 0 5 0 B I c I o I E I F I G I H GAS METER UY PUGET SOUND ENERGY, 533 CFH AT 2PSI OU-rLET PRESSUR F ,. - -- I I I I I . �. •, - I E I 1 I 1 I I II I I �✓ LADDER ACCESS I I (E)EXHAUST FAN I I I j I II I I 1 i , HVAC -I, PROVIDE � IPLATFORM I I WlCURB ADAPTOR O.6Cd. I APPROX LOCATION OF (E) RAILING ON I DUCT PENETRATION THRU I I I PLATFORM , ROOF. ODES NOT LINE UP W) _ +� a NEW UNIT OPENINGSYP) _ - I - � - - - - - - - - � (E) SKYLIGHT (I-) EXHAUST- - � - - - - - - � _------- - -- - - -- - - - � - - - -- - --- - - - - � - I ' STRUCTURE FAN ' 1 I 1 I I I I i ROOF PLAN HVAC � 1!8. . r SCALE: ', -�} NORTH SCAlE I!8' =1W 6I - J 6 IN 0 I 1 I 1 I { I I I I t , REMOVE (E) ADAPTOR CURS 1 lits it ' � —(•tti 11 .* REMOVE (E)+40 -TON REMOVE (E) ACCESS rELECTRICOOIPLATFORM PACKAGED UNIT -- - - -T- -^ —_!- - - - tI - —>I- - - - - - - - —� - I ' II ! I I FANHAUST I I I I �tOr - I I , I I I F 71 I , -I------ - - - _ ,,__..--- - -- - - -� -�- - - - - - - -- - - - - - - --t-- - - - - - - -- i 1 (I-) SKYLIGHT (E) EXHAUST FAN I , ' 0 c 21 ff ^AK mi ROOF PLAN - DEMO mm SCALE: 1I1M'=1'-0'U d' Is* NORTH SCALE 118'a I'-0' A E F G WN H J GENERAL DOTES: 1. PRc)viDE mrr P -TRAP AND CONOENSATE PIPING ELECTRICAL NOTES: 1 PROVIDE NEW ELECTRICAL CONNECTION TO NEW UNIT. PROVIDE NEW 150 AMP BREAKER IN ELECTRICAL PANEL BELOW GENERAL NOTE : I SEE GENERAL DEMOLITION NOTES ON SHEET MO -M1.0 2 EXISTING UNIT 18 A 40 -TON TRANS VOYAGER ELECTRIC HEAT, ELECTRIC COOL UNIT, MODEL TCD48044.. APPROX 87+99 LBS. (PER 00-08-05 BELLEVUE MECHANICAL AS -BUILT DRAWNGS). 3 REMOVE EXISTING CONTROLS AND POMR CONNECTIONS TO EXISTING UNIT. REMOVE DUCT CONNECTIONS ELECTRICAL NOTES: 1 REMOVE EXISTING ELECTRICAL CONNECTION TO UNIT REMOVE EXISTING BREAKER IN ELECTRICAL PANEL BELOW Is E_\At VED FOR CODE COMPLIANCE APPROVED SEP 2 2 2016 City of Tukwila BUILDING DIVISION PERMIT SET � I K K 3 0 5 2 9 9 REC-EWEI TY OF TUK SEP 12 2( ERMI i CEN A 0 —i K Ell z A � g UNIT SA CONNECTION LOCATION DIVIDER PLENUM TO ALLOW NEWOPENING LOCATIONS TO FUNCTION c HVAC -1 0 ^-„-y 1 I j i EXISTING CURB I r r I r I 1 EXISTING SA DUCT EXISTING? RA DUCT SI DE ELEVATION- EW UNIT RA CONNECTION LOCATION (E) ROOF r------- ------------------ i � REMOVE (E) UNIT r I � � I Lr-------_.—_.---------------.r.� REMOVE (E)CURBS EXISTING CURB -- tE] RC?{7F _..._' SIDE ELEVATION- DECO 0 F OFFSET CURB ADAPTOR To PROVIDE 48" CLEARANCE FROM (E) SKYLIGHT STRUCTURE G HVACA EXISTING CURB I PROVIDE WORKING PLATFORM WTH GUARD ON ONE SINE. 2.5'X2.5' ANGLE IRON VNTH STEEL GRATING, ALL HOT DIP GALVANIZED r (E) SKYLIGHT STRUCTURE jJ STEEL LADDER ACCESS J TO PLATFORM ESD ELEV,ATFO("'I' - NEW r ----------I REMOVE EXISTING REMOVE (E) UNIT i I PLATFORM I I � REMOVE (E) CURBS L �.-- - EXISTING CURB ROOFTOP UNIT ELEVATIONS SCALE. 1/4'7= 1'.Cr C.7 (6 M3.3 -- ROOF 6 10 END ELEVATIOIq - DE iO (E) SKYLIGHT STRUCTURE SIZE TO MATCH UNIT CONN (UNCI) EXTEND REGULATOR VENT FULL SIZE MINIMUM OF 10, FROM ADJACENT AIR INTAKE$ a 1'ASOVE GAS REGULATOR, SIZED FOR 2 LBS IN, 7' W.C. OUT. CAPACITY 70 MATCH UNIT � CAPACITY (U NO) SIZE PER PLAN I G MIN 6" DRIP LEG nt1c: n 1 1 U ALLVVV KQQM FOR DRIP LEG REMOVAL ROOFTOP UNGAS COAL I (E) ROOF (E) ROOF UNIT CURB NTS MU M4.1 s o 1 m c6 I tito Ln 2c8 .0 Im F v }i t t 3 T: t 4 < W0 r co ?.>cr) _ `'C oil woi j = Fry LU T 0 CL T 6 REVIEWED FOR CODE COMPLIANCE APPROVED SEP 2 2 2016 City of Tukwila BUILDING DIVISION SIGNED f til r O 6 W Q) W { ILL! LU C) W" }C fn 10 REVIEWED FOR CODE COMPLIANCE APPROVED SEP 2 2 2016 City of Tukwila BUILDING DIVISION m 0 i.x Am. 10 { i1 PERMIT SET I' SHEET 512E IS TRVE SCAEE WHEN 1 { ABOYE ur.£ WEi SJRES 115 NOTIjO A� r I � � ! F G P K } _C Y f til r O W w fn 10 I �1 E m 0 i.x Am. 10 { i1 PERMIT SET I' SHEET 512E IS TRVE SCAEE WHEN 1 { ABOYE ur.£ WEi SJRES 115 NOTIjO A� r I � � ! F G P K } _C