HomeMy WebLinkAboutPermit M16-0150 - COURTYARD MARRIOTT - DUCTLESS SPLIT SYSTEM HEAT PUMPCOURTYARD MARRIOTT
400 ANDOVER PARK W
M16=0150
r; City of Tukwila
Department of Community Development
`� • 6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206-431-3670
Inspection Request Line: 206-438-9350
Web site: http://www.TukwilaWA.gov
MECHANICAL PERMIT
Parcel No: 2623049006 Permit Number: M16-0150
Address: 400 ANDOVER PARK W Issue Date: 10/4/2016
Permit Expires On: 4/2/2017
Project Name: COURTYARD MARRIOTT
Owner:
Name: CBM TWO HOTLES
Address: 1717 MCKINNEY AVE #1900 C/O
CLARION PARTNERS, DALLAS, WA,
75202
Contact Person:
Name: MONTE LONG
Address: 13620 IST AVE S, BURIEN, WA, 98168
Contractor:
2015
Name:
WASHINGTON HEATING & A/C INC
Address:
13620 FIRST AVE S, SEATTLE, WA,
WA Cities Electrical Code:
98114
License No:
WASHIHA012LQ
Lender:
2014
Name:
2015
Address:
2015
Phone: (206) 396-5528
Phone: (206) 860-3832
Expiration Date: 6/16/2018
DESCRIPTION OF WORK:
PROVIDE AND INSTALL ONE TON DUCTLESS SPLIT SYSTEM HEAT PUMP FOR EACH ELEVATOR MACHINE ROOM.
TYPICAL OF 2
Valuation of Work: $8,600.00 Fees Collected: $311.22
Type of Work: NEW Electrical Service Provided by: PUGEST SOUND ENERGY
Fuel type: ELECT Water District: TUKWILA
Sewer District: TUKWILA
Current Codes adopted by the City of Tukwila:
International Building Code Edition:
2015
National Electrical Code:
2014
International Residential Code Edition:
2015
WA Cities Electrical Code:
2014
International Mechanical Code Edition:
2015
WAC 296-466:
2014
Uniform Plumbing Code Edition:
2015
WA State Energy Code:
2015
International Fuel Gas Code:
2015
Permit Center Authorized Signature: ;Z' -5�/- Z'Z !/(/ Date: lU 4<
I hearby certify that I have read and examined this permit and know the same to be true and correct. All
provisions of law and ordinances governing this work will be complied with, whether specified herein or not.
The granting of this permit does not presume to give authority to violate or cancel the provisions of any other
state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this
development permit and agree to the conditions attached to this permit.
Signature: f_ _ _ _ _ Date:
Print Name: Lo N
This permit shall become null and void if the work is not commenced within 180 days for the date of issuance, or if
the work is suspended or abandoned for a period of 180 days from the last inspection.
PERMIT CONDITIONS:
1: Work shall be installed in accordance with the approved construction documents, and any changes made
during construction that are not in accordance with the approved construction documents shall be
resubmitted for approval.
2: All permits, inspection record card and approved construction documents shall be kept at the site of work
and shall be open to inspection by the Building Inspector until final inspection approval is granted.
3: Readily accessible access to roof mounted equipment is required.
4: All construction shall be done in conformance with the Washington State Building Code and the
Washington State Energy Code.
5: Remove all demolition rubble and loose miscellaneous material from lot or parcel of ground, properly cap
the sanitary sewer connections, and properly fill or otherwise protect all basements, cellars, septic tanks,
wells, and other excavations. Final inspection approval will be determined by the building inspector based
on satisfactory completion of this requirement.
6: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the
City of Tukwila Building Department (206-431-3670).
7: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila
Permit Center.
8: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an
approval of, any violation of any of the provisions of the building code or of any other ordinances of the City
of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other
ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction
documents and other data shall not prevent the Building Official from requiring the correction of errors in
the construction documents and other data.
9: `MECHANICAL PERMIT CONDITIONS'
10: All mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila
Permit Center (206/431-3670).
11: Manufacturers installation instructions shall be available on the job site at the time of inspection.
PERMIT INSPECTIONS REQUIRED
Permit Inspection Line: (206) 438-9350
0703
MECH EQUIP EFF
1800
MECHANICAL FINAL
0705
REFRIGERATION EQUIP
0701
ROUGH -IN MECHANICAL
CITY OF TUKfffLA
•
Community Development Department
Permit Center
• 6300 Southcenter Blvd., Suite 100
Tukwila, WA 98188
http://www.TukwilaWA.gov
Mechanical Permit No. 0
Project No.
Date Application Accepted:
Date Application Expires:
MECHANICAL PERMIT APPLICATION
Applications and plans must be complete in order to be accepted for plan review.
Applications will not be accepted through the mail or by fax.
**please print**
SITE LOCATION ::1
King Co Assessor's Tax No.:
Site Address: 400 Andover Park West Suite Number: Floor:
Tenant Name:— Courtyard by Marriott New Tenant: ❑ .....Yes ®..No
PROPERTY OWNER
Name:
Address:
City: State: Zip:
CONTACT PERSON — person receiving all project
communication
Name: Monte Long
Address: 136201st Ave. South
City: Burien State: WA Zip: 98168
Phone: (206) 396-5528 Fax: (206) 860-3832
Email: mrlong@washingtonheating.com
Valuation of project (contractor's bid price):
Describe the scope of work in detail:
•11
MECHANICAL CONTRACTOR INFORMATION
Company Name: Washington Heating & A/C Inc.
Address: 13620 1 st Ave. South
City: Burien State: WA Zip: 98168
Phone: (206) 860-3832 Fax: (206) 860-3799
Contr Reg No.: WASHIHAO12LQ Exp Date: 06/16/2017
Tukwila Business License No.: BUS -0996522
Provide and install (1) 1 ton ductless split system heat pump for each elevator machine room. Typical of 2
Use: Residential:
New
.......... ❑
Replacement ........
❑
Commercial:
New
.......... LZ
Replacement ........
❑
Fuel Type: Electric.....
LZ
Gas .......
❑ Other:_
H:1ApplicationslFomts-Applications On Line12016 Applications\Mechanical Permit Application Revised 14-16.docx
Revised: January 2016 Pagel of 2
bh
Indicate type of mechanical work being installed and the quantity below:
Unit Type
Qty
Furnace <100k btu
Residential, Nighttime
Furnace >100k btu
Industrial
Floor furnace
55 dB(A)
Suspended/wall/floor
mounted heater
57 dB(A)
Appliance vent
Commercial
Repair or addition to
heat/refrig/cooling
system
47 dB(A)
Air handling unit
<10,000 cfm
65 dB(A)
Air handling unit
>10,000 cfin
Evaporator cooler
Ventilation fan
connected to single duct
Ventilation system
Hood and duct
Incinerator — domestic
Incinerator —
comm/industrial
Unit Type
Fire damper
Diffuser
Thermostat
Wood/gas stove
Emergency enerator
Other mechanical 2
equipment
Boiler/Compressor Qty +
0-3 hp/100,000 btu
3-15 h /500,000 btu
15-30 hp/1,000,000 btu
30-50 hp/1,750,000 btu
50+ h /1,750,000 btu
Noise:
Mechanical units need to be in compliance with the Tukwila Noise Code. Maximum permissible sound levels are based on from where the sound is
created and where the sound is heard. Additionally, if sound can be heard from within a house at night in a residential zone it may not be allowed.
For more details, see TMC 8.22
District of Sound
Producing Source
District of Receiving Property
Residential, Daytime*
Residential, Nighttime
Commercial
Industrial
Residential
55 dB(A)
45 dB(A)
57 dB(A)
60 dB(A)
Commercial
57 dB(A)
47 dB(A)
60 dB(A)
65 dB(A)
Industrial
60 dB(A)
50 dB(A)
65 dB(A)
70 dB(A)
*Daytime means 7AM-10PM, Monday through Friday and 8AM-1 OPM, Saturday, Sunday and State -recognized holidays.
A few sounds are exempt from the noise code, including:
Warning devices;
Construction and property maintenance during the daytime hours (lam -1 Opm);
Testing of backup generators during the day.
PEI2MT APFIITCA�TIOlYtO + 5 x a
ti �5
Value of construction — in all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject
to possible revision by the permit center to comply with current fee schedules.
Expiration of plan review — applications for which no permit is issued within 180 days following the date of application shall expire by limitation.
The building official may grant one extension of time for additional periods not to exceed 90 days each. The extension shall be requested in writing
and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition).
I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER
PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT.
BUILDING OWNER OR AUTHORIZED AGENT:
Signature: i�''�_ f Date:
Print Name: Monte Long Day Telephone: (206) 860-3832
Mailing Address: 13620 1St. Ave. South
Burien
city
WA 98168
State Zip
H:\Applications\Fonns-Applications On Line\2016 ApplicationsWechanical Permit Application Revised 1-4-16.docx
Revised: January 2016 Page 2 of 2
bh
DESCRIPTIONS
ACCOUNT
QUANTITY
PAID
PermitTRAK
$311.22
M16-0150 Address: 400 ANDOVER PARK W
Apn: 2623049006
$311.22
MECHANICAL
$299.25
PERMIT ISSUANCE BASE FEE
R000.322.100.00.00
0.00
$32.50
PERMIT FEE
R000.322.100.00.00
0.00
$206.90
PLAN CHECK FEE
R000.322.102.00.00
0.00
$59.85
TECHNOLOGY FEE
$11.97
TECHNOLOGY FEE
TOTAL FEES PAID BY RECEIPT: ..48.
R000.322.900.04.00
0.00
$11.97
Date Paid: Friday, September 23, 2016
Paid By: WASHINGTON HEAT & AC
Pay Method: CREDIT CARD 01948G
Printed: Friday, September 23, 2016 2:25 PM 1 of 1 (rl r
SY57EM5
INSPECTION RECORD _
Retain a copy with permit riri 16
INSPECTION NO. PERMIT NO.
CITY OF TUKWILA BUILDING DIVISION
6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670
Permit Inspection Request Line (206) 438-9350
1% Approved per applicable codes. El Corrections required prior to approval.
COMMENTS:
Inspector: ---7* <-- Date:
F] REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be
paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection.
INSPECTION RECORD
Retain a copy with permit1�,��iS
INS P ION N0. PERMIT N0.
CITY OF TUKWILA BUILDING DIVISION
6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670
Permit Inspection Request Line (206) 438-9350
Pro' ct:
T ti, ,ajor -
Type of Inspection:
€ MVIat- rifAL
Address:
Date Called:
460 bn k
Special Instructions.
Date Wante": m
I MI 1 % P. .
Requester.
CALL
one No:
rZ106C,. 3q6 - S S-2-0
7
(inspector: (Date:)]/(7/l/7
]/(7/lj7 I
FJ REINSPECTION FEE REQUIRED. Prior to next inspehon, fee must be
paid at 6300 Southcenter Blvd., Suite 100. Call. to schedule reinspection.
PERMIT COORD COPY
PLAN REVIEW/ROUTING SLIP
PERMIT NUMBER: M16-0150 DATE: 09/26/16
PROJECT NAME: COURTYARD MARRIOTT
SITE ADDRESS: 400 ANDOVER PARK W
X Original Plan Submittal Revision # before Permit Issued
Response to Correction Letter # Revision # after Permit Issued
DEPARTMENTS:
-T- &
lding Divi
wision
Public Works ❑
PRELIMINARY REVIEW:
Not Applicable ❑
(no approvallreview required)
REVIEWER'S INITIALS:
APPROVALS OR CORRECTIONS:
Approved ❑
Corrections Required ❑
(corrections entered in Reviews)
Notation:
REVIEWER'S INITIALS:
/M 0/w
Fire Prevention
Structural ❑
Planning Division ❑
Permit Coordinator ❑
DATE: 09/27/16
Structural Review Required ❑
DATE:
DUE DATE: 10/25/16
Approved with Conditions e
Denied ❑
(ie: Zoning Issues)
DATE:
Permit Center Use Only
CORRECTION LETTER MAILED:
Departments issued corrections: Bldg ❑ Fire ❑ Plug ❑ PW ❑ Staff Initials:
12/19/2013
WASHINGTON HEATING & A/C TNC
4nWashington State Department of
Labor & Industries
Page 1 of 2
Home lspahol Cont'ad. Search L&I �
A-ZIndex Help MYL&I
Safety & Health Claims & Insurance Workplace Rights Trades & Licensing
WASHINGTON HEATING & A/C INC
Owner or tradesperson
13620 FIRST AVE S
Developers Surety & Indem Co
SEATTLE, WA 98168
Principals
206-860-3832
TRAN, STEVEN c, PRESIDENT
KING County
LONG, MONTHEA R, VICE PRESIDENT
Effective date
PECH, MAKARA, SECRETARY
06116/2011
(End: 05/30/2008)
Expiration date
LONG, MAKARA, PRESIDENT
Until Canceled
(End: 06/17/2008)
Doing business as
WASHINGTON HEATING & A/C INC
WA UBI No. Business type
601 962 099 Corporation
Governing persons
MONTHEA
R
LONG
STEVEN TRAN;
License
Verify the contractor's active registration / license / certification (depending on trade) and any past violations.
Construction Contractor. Active.
..........................................................
Meets current requirements.
License specialties
Heating[Vent/Air-Conditioning and Refrig
(HVAC/R)
License no.
WASHIHAO12LQ
Effective — expiration
06/18/1999— 06/16/2018
Bond
Developers Surety & Indem Co
$6,000.00
Bond account no.
252216C
Received by L&I
Effective date
05/25/2011
06116/2011
Expiration date
Until Canceled
Bond history
Insurance
.......................
Ohio Security Ins Co $1,000,000.00
Policy no.
BKS53513733
Received by L&I Effective date
05/12/2016 06/16/2011
https:Hsecure.Ini.wa.gov/verify/Detail.aspx?UBI=601962099&LIC=WASHIHAO 12LQ&SAW=
Help us improve
10/3/2016
EQUIPIENT SCHEDULE
TAGi
OHP -1
MAKE
DAIKIN
MODEL:
RX12NMVJU
COOLING:
12,000 BTU/H
ELECT:
208V 1PH AMP=15
SEERi
19 SEER
SOUND:.
45dBA
WEIGHT:
60 LBS
CFMi
PROJECT DATAi
COURTYARD BY MARRIOTT
400 ANDOVER PARK WEST
TUKWILA, WA 98188
PARCEL # 2626049006
FC -1
DAIKIN
FTX12NMVJU
12,000 BTU/H
208 V 1PH MCA=1
20 LBS
380
SCOPE OF WORK:
INSTALL (1) 1 TON DUCTLESS SPLIT HEAT
PUMP TO SERVE THE ELEVATOR MACHINE
ROOM.
LEGAL DESCRIPTION,
POR OF SE 1/4 OF NE 1/4 & OF SE 1/4 DAF COMM SW
COR OF SD SE 1/4 OF NE 1/4 TH N 01-05-05 E
ALG 4/ LN 609.06 FT TH S 88-16-17 E 30 FT TO E
MGN & POB TH CONTG S 88-16-77 E 376.72 FT TO W LN
OF LOT 4 OF ANDOVER INDUSTRIAL PARK NO 5 TH
SLY ALG W LOT LN ON THE CURVE TO LFT CENTER BEARING
S 76-02-44 E RAD OF 410,28 FT THRU C/A OF 12-09-48 ARC
DIST 87.10 FT TH CONTG ALG SD LOT LN S 01-47=28 W 136.73 FT
TH ALG CURVE TO THE RGT RAD OF 410.28 FT THRU C/A OF 82-57-36 ARC
DIST OF 594,06 FT TO SD E MGN OF RD TH N
01-47-28 E ALG SD MGN OF RD 21.10 FT TO S LN OF
SD SUBD TH N 01-05-05 E 608.90 FT TO POB PER
CITY OF TUKWILA BDRY LN ADJ NO 86-61--BLA
RECORDING NO 8612171457
OHP -1
CEILING
EC -1
ELEVATOR' I
MACHINE 7
ROOM
SITE PLAN
NTS
HVAC ELEVATION PLAN
SCALE= 1/4' = 1'-0"
MS.
ize
Diet
pd:
VILA
16
Washington Heating
and AC, inc
13620 1st Avenue South
Buden, Washington 98168
ph: (206) 860-3832 fax: (206) 860-3799
Contractor's License No.: WASHIHAO12LQ
www.washingtonheating.com
STAMP
t3
cn
Q
C5 a.
oc
DRAFSWNG 777LES
WAC FLOOR PIAN
PRO,ECT MANAGER
RSL
DESIGNED BY
ST
DRAVN BY
CHECKED BY
ST
ST
SCALE
PROSECT NO.
AS NOTED
201643
THIS DRAWING IS THE SOLE PROPERTY OF WASHINGTON
HEATING do AIR CONDITIONG, INC. ANY REPRODUCTION,
DUPLICATION, ADDITIONS AND/ MIODlRCATIONS REQUIRE
THE WRITTEN APPROVAL OF WASHINGTON HEATING do AIR
CONDITIONING. INC.
'ER I SHEET NUMBER
N
016, C A
EQUIPIENT SCHEDULE
TAGi
OHP -1
MAKE
DAIKIN
MODEL:
RX12NMVJU
COOLING:
12,000 BTU/H
ELECT:
208V 1PH AMP=15
SEERi
19 SEER
SOUND:.
45dBA
WEIGHT:
60 LBS
CFMi
PROJECT DATAi
COURTYARD BY MARRIOTT
400 ANDOVER PARK WEST
TUKWILA, WA 98188
PARCEL # 2626049006
FC -1
DAIKIN
FTX12NMVJU
12,000 BTU/H
208 V 1PH MCA=1
20 LBS
380
SCOPE OF WORK:
INSTALL (1) 1 TON DUCTLESS SPLIT HEAT
PUMP TO SERVE THE ELEVATOR MACHINE
ROOM.
LEGAL DESCRIPTION,
POR OF SE 1/4 OF NE 1/4 & OF SE 1/4 DAF COMM SW
COR OF SD SE 1/4 OF NE 1/4 TH N 01-05-05 E
ALG 4/ LN 609.06 FT TH S 88-16-17 E 30 FT TO E
MGN & POB TH CONTG S 88-16-77 E 376.72 FT TO W LN
OF LOT 4 OF ANDOVER INDUSTRIAL PARK NO 5 TH
SLY ALG W LOT LN ON THE CURVE TO LFT CENTER BEARING
S 76-02-44 E RAD OF 410,28 FT THRU C/A OF 12-09-48 ARC
DIST 87.10 FT TH CONTG ALG SD LOT LN S 01-47=28 W 136.73 FT
TH ALG CURVE TO THE RGT RAD OF 410.28 FT THRU C/A OF 82-57-36 ARC
DIST OF 594,06 FT TO SD E MGN OF RD TH N
01-47-28 E ALG SD MGN OF RD 21.10 FT TO S LN OF
SD SUBD TH N 01-05-05 E 608.90 FT TO POB PER
CITY OF TUKWILA BDRY LN ADJ NO 86-61--BLA
RECORDING NO 8612171457
OHP -1
CEILING
EC -1
ELEVATOR' I
MACHINE 7
ROOM
SITE PLAN
NTS
HVAC ELEVATION PLAN
SCALE= 1/4' = 1'-0"
MS.
ize
Diet
pd:
VILA
16
Washington Heating
and AC, inc
13620 1st Avenue South
Buden, Washington 98168
ph: (206) 860-3832 fax: (206) 860-3799
Contractor's License No.: WASHIHAO12LQ
www.washingtonheating.com
STAMP
t3
cn
Q
C5 a.
oc
DRAFSWNG 777LES
WAC FLOOR PIAN
PRO,ECT MANAGER
RSL
DESIGNED BY
ST
DRAVN BY
CHECKED BY
ST
ST
SCALE
PROSECT NO.
AS NOTED
201643
THIS DRAWING IS THE SOLE PROPERTY OF WASHINGTON
HEATING do AIR CONDITIONG, INC. ANY REPRODUCTION,
DUPLICATION, ADDITIONS AND/ MIODlRCATIONS REQUIRE
THE WRITTEN APPROVAL OF WASHINGTON HEATING do AIR
CONDITIONING. INC.
'ER I SHEET NUMBER
N
016, C A