Loading...
HomeMy WebLinkAboutPermit M16-0156 - MUSEUM OF FLIGHT - PIPE FAN COIL UNITMUSEUM OF FLIGHT M16-0156 City of Tukwila ' Department of Community Development + 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Inspection Request Line: 206-438-9350 Web site: http://www.TukwilaWA.Rov MECHANICAL PERMIT Parcel No: 3324049019 Permit Number: M16-0156 Address: 9404 E MARGINAL WAY S Issue Date: 10/18/2016 Permit Expires On: 4/16/2017 Project Name: MUSEUM OF FLIGHT Owner: Name: MUSEUM OF FLIGHT FOUNDATION Address: 9404 EAST MARGINAL WY S, SEATTLE, Phone: (206) 364-9900 Phone: (206) 364-9900 Expiration Date: 10/3/2018 DESCRIPTION OF WORK: (1) NEW 1,800 CFM 4 PIPE FAN COIL UNITWITH AIR ECONOMIZER. (1) INLINE EXHAUST FAN LOCATED ABOVE THE CEILING WITH AIR DISCHARGED THROUGH AN EXISTING WALL LOUVER AS DEPICTED ON THE PLANS. NEW GALVANIZED SHEET METAL DUCTWORK FOR SUPPLY, OUTSIDE AIR AND EXHAUST. NEW AIR DISTRIBUTION TO SERVE THE RENOVATED SPACE. NEW CHILLED WATER, HOT WATER AND CONDENSATE PIPING. Valuation of Work: $60,000.00 Fees Collected: $982.42 Type of Work: NEW Electrical Service Provided by: SEATTLE CITY LIGHT Fuel type: ELECT Water District: TUKWILA Sewer District: TUKWILA Current Codes adopted by the City of Tukwila: International Building Code Edition: WA, 98108 Contact Person: 2014 Name: ROBJOHNSON Address: 1161149 PL W, MUKILTEO, WA, International Mechanical Code Edition: 98275 Contractor: 2014 Name: UNIVERSITY MECH CONTR INC Address: 11611 49TH PL W, MUKILTEO, WA, International Fuel Gas Code: 98275-4255 License No: UNIVMC*343N9 Lender: Name: Address: Phone: (206) 364-9900 Phone: (206) 364-9900 Expiration Date: 10/3/2018 DESCRIPTION OF WORK: (1) NEW 1,800 CFM 4 PIPE FAN COIL UNITWITH AIR ECONOMIZER. (1) INLINE EXHAUST FAN LOCATED ABOVE THE CEILING WITH AIR DISCHARGED THROUGH AN EXISTING WALL LOUVER AS DEPICTED ON THE PLANS. NEW GALVANIZED SHEET METAL DUCTWORK FOR SUPPLY, OUTSIDE AIR AND EXHAUST. NEW AIR DISTRIBUTION TO SERVE THE RENOVATED SPACE. NEW CHILLED WATER, HOT WATER AND CONDENSATE PIPING. Valuation of Work: $60,000.00 Fees Collected: $982.42 Type of Work: NEW Electrical Service Provided by: SEATTLE CITY LIGHT Fuel type: ELECT Water District: TUKWILA Sewer District: TUKWILA Current Codes adopted by the City of Tukwila: International Building Code Edition: 2015 National Electrical Code: 2014 International Residential Code Edition: 2015 WA Cities Electrical Code: 2014 International Mechanical Code Edition: 2015 WAC 296-4613: 2014 Uniform Plumbing Code Edition: 2015 WA State Energy Code: 2015 International Fuel Gas Code: 2015 r &- ap Permit Center Authorized Signature: Date: I hearby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this development permit and agree to the cooitions attached to this permit. Signatu Print M Date: This permit shall become null and void if the work is not commenced within 180 days for the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. PERMIT CONDITIONS: 1: Work shall be installed in accordance with the approved construction documents, and any changes made during construction that are not in accordance with the approved construction documents shall be resubmitted for approval. 2: All permits, inspection record card and approved construction documents shall be kept at the site of work and shall be open to inspection by the Building Inspector until final inspection approval is granted. 3: Readily accessible access to roof mounted equipment is required. 4: All construction shall be done in conformance with the Washington State Building Code and the Washington State Energy Code. 5: Remove all demolition rubble and loose miscellaneous material from lot or parcel of ground, properly cap the sanitary sewer connections, and properly fill or otherwise protect all basements, cellars, septic tanks, wells, and other excavations. Final inspection approval will be determined by the building inspector based on satisfactory completion of this requirement. 6: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206-431-3670). 7: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center. 8: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. 9: `MECHANICAL PERMIT CONDITIONS' 10: All mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center (206/431-3670). 11: Manufacturers installation instructions shall be available on the job site at the time of inspection. PERMIT INSPECTIONS REQUIRED Permit Inspection Line: (206) 438-9350 0703 MECH EQUIP EFF 1800 MECHANICAL FINAL 0609 PIPE/DUCT INSULATION 0705 REFRIGERATION EQUIP 0701 ROUGH -IN MECHANICAL t CITY OF TUKWILA Community Development Department Permit Center `` _ • 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http:/,•'www.TukwilaWA.govv SITE LOCATION Mechanical Permit No. Project No. Date Application Accepted: Date Application Expires: use MECHANICAL PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. **please print** King Co Assessor's Tax No.: 3324049019 Site Address: 9404 E Marginal Way S, Seattle, WA 98108 Suite Number: n/a Floor: B, 1 Tenant Name: Museum of Flight New Tenant: ❑ .....Yes ®..No PROPERTY OWNER Name: Museum of Flight Address: 9404 E Marginal Way S City: Seattle State: WA Zip: 98108 CONTACT PERSON — person receiving all project communication Name: Rob Johnson Address: 1161149th Place West City: Mukilteo State: WA Zip: 98275 Phone: (206) 364-9900 Fax: (206) 365-1580 Email: rjohnson@umci.com Valuation of project (contractor's bid price): $ 60,000 Describe the scope of work in detail: MECHANICAL CONTRACTOR INFORMATION Company Name: University Mechanical Contractors, Address: 11611 49th Place West City: Mukilteo State: WA Zip: 98275 Phone: (206) 364-9900 Fax: (206) 365-1580 Contr Reg No.: UNIVMC*343N9 Exp Date: Tukwila Business License NO.: BUS -0994385 (1) New 1,800 CFM 4 pipe fan coil unit with air economizer. (1) Inline exhaust fan located above the ceiling with air discharged through an existing wall louver as depicted on the plans. New galvanized sheet metal ductwork for supply, outside air, and exhaust. New air distribution to serve the renovated space. New chilled water, hot water, and condensate piping. Use: Residential: New .......... ❑ Replacement ........ ❑ Commercial: New .......... 6d Replacement ........ ❑ Fuel Type: Electric..... ® Gas....... ❑ Other:_ 1J:\Applicalions\For -Applications On Line\2016 Applications\Mcchanical Permit Application Revised 1-4-16.docx Revised: January 2016 Page 1 of 2 bh Indicate type of mechanical work being installed and the quantity below: Unit Type Qty Furnace <I 00k btu Residential, Nighttime Furnace >I 00k btu 5 Floor furnace 1 Suspended/wall/floor mounted heater 57 dB(A) Appliance vent Commercial Repair or addition to heat/refrig/cooling system 47 dB(A) Air handling unit <I0,000 cfm 1 Unit Type Qty Air handling unit >I0,000 cfrn Residential, Nighttime Evaporator cooler 5 Ventilation fan connected to single duct 1 Ventilation system 57 dB(A) Hood and duct Commercial Incinerator — domestic 47 dB(A) Incinerator — comm/industrial 65 dB(A) Unit Type Qty Fire damper Residential, Nighttime Diffuser 5 Thermostat 1 Wood/gas stove 57 dB(A) Emergency enerator Commercial Other mechanical equipment 47 dB(A) 60 dB(A) 65 dB(A) Boiler/Compressor Qty 0-3 hp/100,000 btu 3-15.h2/500,000 btu 15-30 hp/1,000,000 btu 30-50 hp/1,750,000 btu 50+h /1,750,000 btu Noise: Mechanical units need to be in compliance with the Tukwila Noise Code. Maximum permissible sound levels are based on from where the sound is created and where the sound is heard. Additionally, if sound can be heard from within a house at night in a residential zone it may not be allowed. For more details, see TMC 8.22 District of Sound Producing Source District of Receiving Property Residential, Daytime* Residential, Nighttime Commercial Industrial Residential 55 dB(A) 45 dB(A) 57 dB(A) 60 dB(A) Commercial 57 dB(A) 47 dB(A) 60 dB(A) 65 dB(A) Industrial 60 dB(A) 50 dB(A) 65 dB(A) 70 dB(A) *Daytime means 7AM-IOPM, Monday through Friday and 8AM-IOPM, Saturday, Sunday and State -recognized holidays. A few sounds are exempt from the noise code, including: Warning devices; Construction and property maintenance during the daytime hours (7am-10pm); Testing of backup generators during the day. PERMIT APPLICATION NOTES - Value of construction — in all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the permit center to comply with current fee schedules. Expiration of plan review — applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The building official may grant one extension of time for additional periods not to exceed 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER OR AUTHORIZED AGENT: Signature: -z?� Date: 10/03/2016 Print Name: Robert Johnson Day Telephone: (206) 402-1774 Mailing Address: 11611 49th Place West Mukilteo WA 98275 City State Zip H:WpplicalionsWo—s-Applications On Line\2016 ApplicationsWechanical Permit Application Revised 1-4-16.docx Revised: Ianaary 2016 Page 2 of 2 bh DESCRIPTIONS PermitTRAK ACCOUNT QUANTITY PAID $982.42 M16-0156 Address: 9404 E MARGINAL WAY S Apn: 3324049019 $982.42 MECHANICAL $944.63 PERMIT ISSUANCE BASE FEE R000.322.100.00.00 0.00 $32.50 PERMIT FEE R000.322.100.00.00 0.00 $723.20 PLAN CHECK FEE R000.322.102.00.00 0.00 $188.93 TECHNOLOGY FEE $37.79 TECHNOLOGY FEE TOTAL.. R000.322.900.04.00 0.00 $37.79 $982.42 Date Paid: Tuesday, October 04, 2016 Paid By: JOEL PEREZ Pay Method: CREDIT CARD 046882 Printed: Tuesday, October 04, 2016 12:14 PM 1 of 1 07-1? SYSTEMS INSPECTION RECORD. Retain a copy with permit IN CTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-367 Permit Inspection Request Line (206) 438-9350 PAct: Type of Inspection: U n ECI+A-I'l CAA- PIA L Address: Date Called: Special Instructions: Date Wante a.m. 1 ZG Request r. N7— Phone No: XApproved per applicable codes. LJ Corrections required prior to approval. I I paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. INSPECTION RECORD r2-)- Retain a copy with permit I A40L 0 SPECTION NO. PERMIT N0. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Project: ft.s60M OF /O -7- Te of Ins ectton: )V6 b0CT— l s(JLA7-I ar i! Addr,eYss: _/ �Y� 1?(s-I /WIV k) Date Ca ed: Special Instructions: 01��%e � Date W��ed / p.m. Request Phone No: Inspector: Date (� F REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. INSPECTION RECORD Retain a copy with permit )G -01 n, E6 *tKPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 5outhcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Project: ^Ju ! {-r'' T e of Inspection: U �+ 'lel CQ4 ,Ja CAL Address: / Al- f: I S Date Called: Special Instructions: Date Wan ed: 100a.m. rn Reques er'' �,,{{�� �%�® t/w"LC, Phone No: i�-341w18- 7R J Inspector: Date: / REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. AIRTESTCo., Inc. N1 . 9 �13 Preliminary Report PROJECT: Museum Of Flight DATE: 12/29/2016 LOCATION: Seattle, WA CONTACT: Neal Otey PROJECT #: FIRM: Airtest Co Inc PHONE: 425-313-0172 PO Box 86 FAX: 425-313-5735 Issaquah, WA 98027 PROJECT: Museum Of Flight 9404 E. Marginal Way S. DATE: 12/29/2016 PROJECT #: Seattle, WA 98108 CONTACT: Otey, Neal NOTES: LE Airtest Co Inc m16-01s� RECEIVED CITY OF TUKWILA DEC 2 9 2016 PERMIT CENTER Preliminary TAB Report 1 of 4 AIRT'EST Co., Inc. Air Handling Unit PROJECT: Museum Of Flight DATE: 12/29/2016 LOCATION: Seattle, WA CONTACT: Neal Otey PROJECT #: SYSTEM/UNIT: AHU-01 Location Service Unit Manufacturer Unit Model Number Unit Serial Number Corridor Daikin LAH005ADH SLPD161000159 Fan Tvpe / Class BI/1 Final Operating Hz 40.5 Hz Motor Volts 1 480 Volts Motor Volts 2 485 Volts Motor Volts 3 482 Volts Motor Amps 1 1.7 Amps Motor Amps 2 1.7 Amps Motor Amos 3 1.7 Amps AHU-01 Supply Outlet Summary Tested By: Neal Otey Date: 12/28/2016 Motor Manufacturer Baldor Motor HP 2 HP Motor RPM 3450 RPM Motor Frame 145T Motor Rated Volts 230/460 Volts Motor Phase 3 Motor Hertz 60 Hz Motor FL Amps 5/2.5 Amps Motor Service Factor 1.15 VFD Model Daikin Sheave Data AHU-01/Supply Fan Size LxW / D 10 RD Drive Type Direct Drive Air Test Data Total Supply CFM Des. 1800 CFM Total Supply CFM Act. 1730 CFM 360 Filter Data AHU-01/SF Filter Bank 96 Filter Manufacturer AAF Filter Type Pleated Filter Quantity 2 Filter Size 24x20x4 Inches System/Unit Outlet -01 Area Served Corridor 104 Outlet Type LD -4 Size LxW / D 10 RD Design CFM 360 Reading 310 Reading 1 355 199 Outlet -02 Corridor 104 LD -4 10 RD 360 300 345 96 Outlet -03 Corridor 104 LD -4 10 RD 360 275 325 90 Outlet -04 Corridor 104 LD -4 10 RD 360 315 360 100 Outlet -05 Corridor 104 Totals::0i CD 10 RD 360 300 1500 345 1730 96 96 Airtest Co Inc Preliminary TAB Report 2 of 4 AIRTEST Co., Inc. Fan Unit PROJECT: Museum Of Flight DATE: 12/29/2016 LOCATION: Seattle, WA CONTACT: Neal Otey PROJECT #: SYSTEM/UNIT: EF -01 AREA: Restrooms Unit Location Mech Room Unit Serves Restrooms Unit Manufacturer Cook Model Number 135SQNH Serial Number 033SG6231 1 -00 Fan Tvoe / Class FC/1 Test Data Fan RPM Design 2082 RPM Fan RPM Actual N/A RPM External SP Design 2 in. we Tested By: Neal Otey Date: 12/28/2016 Motor Manufacturer Motor HP Motor RPM Motor Frame Motor Rated Volts Motor Phase Motor Hertz Motor FL Amps Motor Service Factor 1 1/2 HP 1760 RPM 143/5T 208 - 230 - 460 Volts 3 60 Hz 4.58-4.14/2.07 Amps 1.15 EF -01 Exhaust Inlet Summary System/Unit Inlet -01 Area Served Women's Restroom Drive Type Belt Electrical Test Data Motor Sheave 1 VL40 Motor Volts 1 477 Volts Motor Sheave Bore 7/8" in. Motor Volts 2 477 Volts Fan Sheave N/A Motor Volts 3 482 Volts Fan Sheave Bore 5/8 in. Motor Amps 1 1.6 Amps Belt Size AX40 Motor Amps 2 1.7 Amps Belt Quantity 1 Motor Amps 3 1.7 Amps Sheave Center Line 16 1/2 With Idler tensioner in. Inlet -05 Family Room 102 Totals:00 EG 8 RD Air Test Data 140 1255 93 97 Total Fan CFM Des. 1300 CFM Total Fan CFM Act. 1255 CFM EF -01 Exhaust Inlet Summary System/Unit Inlet -01 Area Served Women's Restroom Outlet .- EG Size LxW / D 12 RD Design CFM 495 Reading 765 Reading 500 101 Inlet -02 Men's Restroom 105 EG 12 RD 415 500 390 94 Inlet -03 First Aid 101 EG 8 RD 115 170 105 91 Inlet -04 Family Room 103 EG 8 RD 125 110 120 96 Inlet -05 Family Room 102 Totals:00 EG 8 RD 150 125 1670 140 1255 93 97 Airtest Co Inc Preliminary TAB Report 3 of 4 AIRTEST Co., Inc. Hydronic Pump PROJECT: Museum Of Flight LOCATION: Seattle, WA PROJECT #: (E) CHW-01 Balance Valve Summary DATE: CONTACT: System/Unit MFG Model Size GPM Actual GPM CBV Design DP Actual Setting Totals: - 12.0 0.0 (E) HW -01 Balance Valve Summary System/Unit MFG Model Size GPM Actual GPM CBV Design DP Actual Setting Totals: 17.0 0.0 Airtest Co Inc j 0 x 12/29/2016 Neal Otey Preliminary TAB Report 4 of 4 AIRTEST Co., Inc. Fan Unit PROJECT: Museum Of Flight LOCATION: Seattle, WA PROJECT #: SYSTEM/UNIT: EF -01 AREA: Restrooms Unit Location Mech Room Unit Serves Restrooms Unit Manufacturer Cook Model Number 135SQNH Serial Number 033SG6231 1 -00 Fan Type / Class FC/1 Test Data Fan RPM Design 2082 RPM Fan RPM Actual N/A RPM External SP Design 2 in. we Electrical Test Data Motor Volts 1 477 Volts Motor Volts 2 477 Volts Motor Volts 3 482 Volts Motor Amps 1 1.6 Amps Motor Amps 2 1.7 Amps Motor Amps 3 1.7 Amps EF -01 Exhaust Inlet Summary DATE: 12/29/2016 CONTACT: Neal Otey Tested By: Neal Otey Date: 12/28/2016 Motor Manufacturer Motor HP Motor RPM Motor Frame Motor Rated Volts Motor Phase Motor Hertz Motor FL Amps Motor Service Factor Drive Type Motor Sheave Motor Sheave Bore Fan Sheave Fan Sheave Bore Belt Size Belt Quantity Sheave Center Line 1 1/2 HP 1760 RPM 143/5T 208 - 230 - 460 Volts 3 60 Hz 4.58-4.14/2.07 Amps 1.15 1VL40 7/8" in. N/A 5/8 in. AX40 1 16 1/2 With Idler tensioner in. Data Total . - Total Fan CFM Des. 1300 CFM Total Fan CFM Act. 1255 CFM Inlet -01 Area Served Women's Restroom Outlet Type EG Size LxW / D 12 RD DesignSystem/Unit CFM 1 495 Reading 7651 Reading 500 11 101 Inlet -02 Men's Restroom 105 EG 12 RD 415 500 390 94 Inlet -03 First Aid 101 EG 8 RD 115 170 105 91 Inlet -04 Family Room 103 EG 8 RD 125 110 120 96 Inlet -05 Family Room 102 Totals:00 EG 8 RD 150 125 1670 140 1255 93 97 Airtest Co Inc Preliminary TAB Report 3 of 4 AIRTEST Co., Inc. Hydronic Pump PROJECT: Museum Of Flight LOCATION: Seattle, WA PROJECT M (E) CHW-01 Balance Valve Summary DATE: 12/29/2016 CONTACT: Neal Otey (E) HW -01 Balance Valve Summary Airtest Co Inc Preliminary TAB Report 4 of 4 AIRIEST Co., Inc. Preliminary Report PROJECT: Museum Of Flight DATE: 12/29/2016 LOCATION: Seattle, WA CONTACT: Neal Otey PROJECT M FIRM: Airtest Co Inc PHONE: 425-313-0172 PO Box 86 FAX: 425-313-5735 Issaquah, WA 98027 PROJECT: Museum Of Flight 9404 E. Marginal Way S. Seattle, WA 98108 NOTES: Airtest Co Inc DATE: 12/29/2016 PROJECT #: CONTACT: Otey, Neal Preliminary TAB Report 1 of 4 AIRTEST Co., Inc. MI 008 Air Handling Unit PROJECT: Museum Of Flight DATE: 12/29/2016 LOCATION: Seattle, WA CONTACT: Neal Otey PROJECT #: SYSTEM/UNIT: AHU-01 40.5 Hz Tested By: Neal Otey 480 Volts Motor Volts 2 Date: 12/28/2016 Motor Volts 3 482 Volts Motor Amps 1 1.7 Amps Motor Amps 2 ...MotorData Motor Amps 3 1.7 Amps Location Mechanical Room Filter Type AHU-01/Supply Fan Service Corridor Filter Size Motor Manufacturer Baldor Unit Manufacturer Daikin Outlet -04 Motor HP 2 HP Unit Model Number LAH005ADH 360 Motor RPM 3450 RPM Unit Serial Number SLPD161000159 Outlet -05 Motor Frame 145T Fan Tvoe / Class BI/1 Final Operating Hz 40.5 Hz Motor Volts 1 480 Volts Motor Volts 2 485 Volts Motor Volts 3 482 Volts Motor Amps 1 1.7 Amps Motor Amps 2 1.7 Amps Motor Amps 3 1.7 Amps AHU-01 Supply Outlet Summary Motor Rated Volts 230/460 Volts Motor Phase 3 Motor Hertz 60 Hz Motor FL Amps 5/2.5 Amps Motor Service Factor 1.15 VFD Model Daikin Sheave Data AHU-01/Suooly Fan Drive Type Direct Drive Design CFM 360 Prelim Reading 310 Total Supply CFM Des. 1800 CFM Total Supply CFM Act. 1730 CFM LD -4 Filter Data AHU-01/SF Filter Bank 1300 Filter Manufacturer AAF Filter Type Pleated Filter Quantity 2 Filter Size 24x20x4 Inches System/Unit Outlet -01 Area Served Corridor 104 Outlet Type LD -4 Size LxW / D 10 RD Design CFM 360 Prelim Reading 310 Final Reading 355 % Final 99 Outlet -02 Corridor 104 LD -4 10 RD 360 1300 345 96 Outlet -03 Corridor 104 LD -4 10 RD 360 275 325 90 Outlet -04 Corridor 104 LD -4 10 RD 360 315 360 100 Outlet -05 Corridor 104 Totals::00 CD 10 RD 360 300 1500 345 1730 96 96 Airtest Co Inc Preliminary TAB Report 2 of 4 vERMIT COOR© COPY.. PLAN REVIEW/ROUTING SLIP PERMIT NUMBER: M16-0156 DATE: 10/04/16 PROJECT NAME: MUSEUM OF FLIGHT SITE ADDRESS: 9404 E MARGINAL WAY S X Original Plan Submittal Revision # before Permit Issued Response to Correction Letter # Revision # after Permit Issued DEPARTMENTS: H AM/ lb Building Divisi a ky ��� 10 -t P ire Preven ton IP Planning Division ❑ Public Works ❑ Structural ❑ Permit Coordinator PRELIMINARY REVIEW: DATE: 10/06/16 Not Applicable ❑ Structural Review Required ❑ (no approval/review required) REVIEWER'S INITIALS: APPROVALS OR CORRECTIONS: Approved n Corrections Required ❑ (corrections entered in Reviews) Notation: DATE: DUE DATE: 11/03/16 Approved with Conditions Denied ❑ (ie: Zoning Issues) REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: 12/18/2013 UNIVERSITY MECH CONTR INC Washington State Department of 4LJ Labor & Industries Page 1 of 3 Horne. Espanol Contact Search L&I ^ l.; _1-L Index help My L&I Safety & Health Claims & Insurance Workplace Rights Trades & Licensing UNIVERSITY MECH CONTR INC Owner or tradesperson Principals BUSH, GERALD D, PRESIDENT SMITH, DOUG, VICE PRESIDENT GRANSTON, EDWARD B, SECRETARY PETTERSON, DEAN M, TREASURER BALDWIN, TERRY L, VICE PRESIDENT (End: 09/10/2003) KOMMERS, EDWARD D, VICE PRESIDENT (End: 09/13/2004) GRANSTON, FRANK, TREASURER (End: 12/23/2002) Doing business as UNIVERSITY MECH CONTR INC 11611 49TH PL W MUKILTEO, WA 98275-4255 206-364-9900 SNOHOMISH County WA UBI No. Business type 578 025 176 Corporation License Verify the contractor's active registration / license / certification (depending on trade) and any past violations. Construction Contractor Active. ................................_....................................... Meets current requirements. License specialties GENERAL License no. UNIVMC*343N9 Effective — expiration 08/29/1966-10/03/2018 Bond FIDELITY & DEPOSIT CO OF MD $12,000.00 Bond account no. 08965196 Received by L&I Effective date 06/04/2009 07/31/2009 Expiration date Until Canceled Insurance ...................... Phoenix Insurance Company, The $1,000,000.00 Policy 110, DTCO526D8270PHX11 Received by L&I Effective date 05/03/2016 06/0112011 https:Hsecure.Ini.wa.gov/verify/Detail.aspx?UBI=578025176&LIC=UNIVMC * 343N9&SAW= Help us improve 10/18/2016 ■ DUCT LINE EOUIVALENTS LEGEND SINGLE LINE DOUBLE LINE DESCRIPTION 9O' ELBOW UP (SUPPLY) 2 90' ELBOW UP (RETURN/EXHAUST) Q--� 90' ELBOW DOWN (SUPPLY) 90' ELBOW DOWN (RETURN/EXHAUST) �-I--� � RADIUS ELBOW UP (SUPPLY) Z4 ----e �� RADIUS ELBOW UP (RETURN/EXHAUST) X�-I--2 RADIUS ELBOW DOWN (SUPPLY) � RADIUS ELBOW DOWN (RETURN/EXHAUST) ROUND DUCT UP (S/R/E) �? ( ROUND DUCT DOWN (S/R/E) TURNING VANE ELBOW fe RADIUS ELBOW, RECT RADIUS ELBOW, ROUND TRANSITION (ROUND ORECTANGU A R ) �-®--2 TRANSITION (RECTANGULAR TO ROUND) RECT � SPIN -IN TAKEOFF -�-- ROUND -� ROUND CONICAL TEE �- ROUND -� TEE WITH TURNING VANES BRANCH TAKEOFF, RECT RECT BRANCH TAKEOFF, ROUND �- ROUND -� RECT BRANCH TEE, RECT RECT CONICAL SPIN -IN TAKEOFF �- ROUND .. ROUND BOOT TEE -E- ROUND4�v -�- 45 LATERAL 45' CONICAL LATERAL A71OCHANGE RRIISEEV (R)NOR DROP (D) I --Z AIR FLOW DIRECTION - SUPPLY -�--H-V -+-� AIR FLOW DIRECTION - RETURN OR EXHAUST ---I]] DUCT END CAP I Vz/46 ����IIIIIIII FLEXIBLE DUCTWORK tMANUAL VOLUME DAMPER R z- 1-� REMOTE VOLUME DAMPER FM FIRE/SMOKE APER -PROVIDE ACCESS FD FIRE DAMPER -PROVIDE ACCESS woo ❑ MOTOR OPERATED DAMPER BDD I eoo BACKDRAFT DAMPER HUMIDIFIER �♦ WALL MOUNTED TSTAT WiTH CONTROL LINE SUPPLY DIFFUSER ® SUPPLY GRILLE RETURN/EXHAUST GRILLE FE_F-_X_1 EQUIPMENT MARK 0 DIFFUSER/GRILLE DESIGNATION 0 ROUND DUCT T=. B=. TOP OF DUCT, BOTTOM OF DUCT Lo r I GENERAL SYMBOL ABBR DESCRIPTION 45 45 DOWN 90 AD ACCESS DOOR IN CEILING AD ACCESS DOOR IN WALL ALIGNMENT GUIDE _ ANCHOR AUTOMATIC CONTOL VALVE (3 -WAY) - AUTOMATIC CONTROL VALVE (2 -WAY) -� BALANCING VALVE �I- BV BALL VALVE oP XX' -XX" BOP BOTTOM OF PIPE ELEVATION BREAK BFV BUTTERFLY VALVE E CAP CENTERLINE xX'-XX" CL -EL CENTERLINE OF PIPE ELEVATION -- CHK CHECK VALVE CIRCUIT SETTER X DETAIL TAG X -X G DN DOWN X ELEVATION TAG i`',r, i 2 P" VA IT l#� )Ui,=D FOR: 0 & echanical Electrical [11'Plumbing Q43 a's Piping C i of Tukwilat St. R.DINO DIVISION PIPING SYMBOL ABBR FLOW ARROW _�- AAV GAS COCK - BFW- BFW GLOBE VALVE _ GV GATE VALVE IE xx'-xx" IE INVERT PIPE ELEVATION PITCH ,, PM W CHR PITCH LEFT PITCH CHS PITCH RIGHT -CR- CR PLUG -CS- POC POINT OF CONNECTION COOLING COIL PG PRESSURE GAUGE _ PRV PRESSURE REDUCING VALVE CEILING CNTFGL ROLLING 45 DOWN - FOR- FOR REDUCER - FOS- FOS REDUCING CONCENTRIC -� FOV REDUCING ECCENTRIC -G RV RELIEF VALVE - GLR- GLR SHEET NOTE DESIGNATION - GLS- GLS SLEEVE - SV SOLENOID VALVE }_ HG TEE DOWN -I- HPS TEE �L- TH THERMOMETER XxxxxxxxX HWS LONG TAG 9 CHARCTERS MAX xxxxxx LCR MEDIUM TAG 6 CHARCTERS MAX FX-X-X-xl LPS SHORT TAG 4 CHARCTERS MAX oP XX' -XX' TOP TOP OF PIPE ELEVATION ---NIH- U UNION _R_ o UP ® MG VERTICAL SLEEVE - MPS- MPS VALVE IN PIPE RISE OR DROP - STIR WYE TYPE STRAINER i`',r, i 2 P" VA IT l#� )Ui,=D FOR: 0 & echanical Electrical [11'Plumbing Q43 a's Piping C i of Tukwilat St. R.DINO DIVISION PIPING SYMBOL ABBR DESCRIPTION ` AAV AUTOMATIC AIR VENT - BFW- BFW BOILER FEED WATER -p- AMS BUCKET TRAP -CA- CA CONTROL AIR - CHR- CHR CHILLED WATER RETURN - CHS- CHS CHILLED WATER SUPPLY -CR- CR CONDENSER WATER RETURN -CS- CS CONDENSER WATER SUPPLY COOLING COIL CFM FLANGE CHLR CHILLER FLEX CEILING CNTFGL FLOAT AND THERMOSTATIC - FOR- FOR FUEL OIL RETURN - FOS- FOS FUEL OIL SUPPLY - FOV- FOV FUEL OIL VENT -G G NATURAL GAS - GLR- GLR GLYCOL RETURN - GLS- GLS GLYCOL SUPPLY - HCR- HCR HIGH PRESSURE CONDENSATE RETURN -HG- HG HOT GAS -HPS- HPS HIGH PRESSURE STEAM - HWR- HWR HEATING HOT WATER RETURN - HWS- HWS HEATING HOT WATER SUPPLY - LCR- LCR LOW PRESSURE CONDENSATE RETURN - LPS- LPS LOW PRESSURE STEAM 0 MAV MANUAL AIR VENT - MCR- MCR MEDIUM PRESSURE CONDENSATE RETURN _R_ o METER -MG- MG MEDIUM PRESSURE NATURAL GAS - MPS- MPS MEDIUM PRESSURE STEAM - PCR- PCR PUMPED CONDENSATE RETURN 0 PI PRESSURE INDICATOR -RL- RL REFER LIQUID -RS- RS REFER SUCTION T C X C- 0- L� TEMPERATURE PRESSURE TEST PLUG Q TI TEMPERATURE INDICATOR TS TS TEMPERATURE SENSOR VB VACUUM BREAKER VENTURI M 0 00 AC AIR CONDITIONING UNIT AF AIRFOIL AFF ABOVE FINISHED FLOOR AHU AIR HANDLING UNIT AMB AMBIENT AMS AIRFLOW MEAQJRING UNIT B BOILER BDD BACKDRAFT DAMPER BHP BRAKE HORSE'OWER BI BACKWARD INCLINED BOD BOTTOM OF DJCT BOT BOTTOM BTUH BRITISH THERMAL UNIT PER HOUR CC COOLING COIL CFM CUBIC FEET PER MINUTE CHLR CHILLER CLG CEILING CNTFGL CENTRIFUGAL COMB COMBUSTION COND CONDENSER / CONDENSATE CONT CONTINUE / CONTROL CONTR CONTRACTOR CP CIRCULATING PUMP CRAC COMPUTER ROOM AIR CONDITIONING UNIT CT COOLING TOWER CU CONDENSING UNIT / CUBIC Cv FLOW COEFFICIENT CV CONSTANT VOLUME CWP CHILLED WATER PUMP D DRAIN DB DRY BULB / )ECIBEL DEG DEGREE DIA DIAMETER DIM DIMENSION DISCH DISCHARGE DMPR DAMPER DN DOWN ... l • •, as EA EXHAUST AIR EAT ENTERING AIR TEMPERATURE ECONO ECONOMIZER EDH ELECTRIC DUCT HEATER EER ENERGY EFFICIENCY RATIO EF EXHAUST FAN EFF EFFICIENCY ELEC ELECTRIC ELEV ELEVATION EQUIV EQUIVALENT ESP EXTERNAL STATIC PRESSURE EVAP EVAPORATOR / EVAPORATIVE EWT ENTERING WATER TEMPERATURE EXH EXHAUST EXT EXTERIOR / EXTERNAL F FAHRENHEIT FC FORWARD CURVE FCU FAN COIL UNIT FD FIRE DAMPER / FLOOR DRAIN FLR FLOOR FLTR FILTER FOIC FURNISHED BY OWNER INSTALLED BY CONTRACTOR FPM FEET PER MINUTE FSD FIRE SMOKE DAMPER FT FEET FTU FAN TERMINAL UNIT FV FACE VELOCITY GA REVISiONS GAL rade to the SCOPO of ~ ,;` ,r approval of GPM Division. NOTE F 2 c a ns,� plan submittal and m--,% : ,_ :zonal pian review fees. 1 ... l • •, as EA EXHAUST AIR EAT ENTERING AIR TEMPERATURE ECONO ECONOMIZER EDH ELECTRIC DUCT HEATER EER ENERGY EFFICIENCY RATIO EF EXHAUST FAN EFF EFFICIENCY ELEC ELECTRIC ELEV ELEVATION EQUIV EQUIVALENT ESP EXTERNAL STATIC PRESSURE EVAP EVAPORATOR / EVAPORATIVE EWT ENTERING WATER TEMPERATURE EXH EXHAUST EXT EXTERIOR / EXTERNAL F FAHRENHEIT FC FORWARD CURVE FCU FAN COIL UNIT FD FIRE DAMPER / FLOOR DRAIN FLR FLOOR FLTR FILTER FOIC FURNISHED BY OWNER INSTALLED BY CONTRACTOR FPM FEET PER MINUTE FSD FIRE SMOKE DAMPER FT FEET FTU FAN TERMINAL UNIT FV FACE VELOCITY GA GAUGE GAL GALLONS GALV GALVANIZED GPM GALLONS PER MINUTE GWB GYPSUM WALLBOARD H HUMIDIFIER HC HEATING COIL HD HEAD HORIZ HORIZONTAL HP HORSEPOWER HT HEAT TRACE HVAC HEATING, VENTILATING, AND AIR CONDITIONING HVACDCS HVAC DUCT CONSTRUCTION STANDARDS, METAL AND FLEXIBLE (SMACNA) HX HEAT EXCHANGER ID INDIRECT DRAIN / INSIDE DIAMETER IN INCH KW KILOWATT L LONG / LENGTH LAT LEAVING AIR TEMPERATURE LB POUND LWT LEAVING WATER TEMPERATURE MBH THOUSAND BTU PER HOUR MECH MECHANICAL MOD MOTOR OPERATED DAMPER MTD MOUNTED MVD MANUAL VOLUME DAMPER NC NORMALLY CLOSED / NOISE CRITERIA NIC NOT IN CONTRACT NO NORMALLY OPEN / NUMBER NTS NOT TO SCALE OBD OPPOSED BLADE DAMPER OC ON CENTER OD OUTSIDE DIMENSION OR DIAMETER OSA OUTSIDE AIR P PUMP PBD PARALLEL BLADE DAMPER PD PRESSURE DROP / PUMPED DRAIN PL PLENUM POC POINT OF CONNECTION PT POST -TENSION SLAB QD QUICK DISCONNECT RA RETURN AIR REF REFERENCE REV REVISION RF RELIEF FAN RH RELATIVE HUMIDITY RIO ROUGH -IN ONLY RPM REVOLUTIONS PER MINUTE SA SUPPLY AIR SCFM STANDARD CUBIC FEET PER MINUTE SCH SCHEDULE SECT SECTION SENS SENSIBLE SF SUPPLY FAN / SQUARE FOOT SL SOUND LINE (INSIDE DUCT INSULATION ) SMACNA SHEET METAL AND AIR CONDITIONING CONTRACTORS NATIONAL ASSOCIATION SP STATIC PRESSURE SQ SQUARE SS STAINLESS STEEL ST SOUND TRAP TBV TOWER BYPASS VALVE TCV TEMPERATURE CONTROL VALVE TDH TOTAL DYNAMIC HEAD TOD TOP OF DUCT TOS TOP OF STEEL TP TOTAL PRESSURE TRNSN TRANSITION TSP TOTAL STATIC PRESSURE TYP TYPICAL UBD UPBLAST DISCHARGE UH UNIT HEATER UNO UNLESS NOTED OTHERWISE VA VALVE VAV VARIABLE AIR VOLUME VD VOLUME DAMPER VENT VENTILATION / VENTILATOR VEL VELOCITY VFO VARIABLE FREQUENCY CONTROLLER A VIBRATION ISOLATOR VIV VARIABLE INLET VANES W INSULATED DUCT / WATT / WIDE WB WET BULB (TEMPERATURE) WG WATER GAUGE WT WEIGHT M2.01 LEVEL 1 MECHANICAL PLAN Permit No, t�_l &-- 0 ( Is - Plan ravieln approval is subject to errors and omissions. Approval of consiruciion docurnents does not authoii1.e the violation of any adopters code or ordinance. Reco ipt of approved Field Copy and condi ' ns s acknovdedv,d: ey: - d 5 �X, XK Date: to Z/ City of Tukwila all III nlnirl nit/101AXII GENERAL NOTES 1. THE MECHANICAL SYSTEM SHALL CONSIST OF ALL WORK SHOWN ON DRAWINGS. DIAGRAMS, AND AS DESCRIBEDIN THE SPECIFICATIONS. 2 INSTALL MECHANICAL WORK AS HIGH AS POSSIBLE, TiGHT TO STRUCTURE ABOVE 3. THE MECHANICAL DRAWINGS ARE SCHEMATIC IN NATURE AND DO NOT ATTEMPT TO SHOW ALL REQUIRED RETAILS. OFFSETS. REFER TO ARCHITECTURAL AND STRUCTURAL DRAWINGS FOR CONSTRUCTION 4. ITEMS NOTED AS 'TYPICAL' OR 'TVP' ON ANY DRAWING APPLY TO THAT PARTICULAR DRAWING. 5. COORDINATE WiTH SPECIFICATIONS. IN CASE OF CONFLICT BETWEEN SPECIFICATIONS AND DRAWINGS THE MORE STRINGENT SHALL APPLY. 6. PROVIDE NEC CODE MINIMUM HORIZONTAL AND VERTICAL WORKING CLEARANCES FOR ALL ELECTRICAL. PANELS AND EQUIPMENT. OFFSET MECHANICAL WORK AS REQUIRED. 7. COORDINATE ALL M8>IAN CA. WORK WITH OTHER TRADES TO INSURE PROPER AND ADEQUATE INTERFACE OF THEIR WORK WiTH THE WORK OF THIS CONTRACTOR PROVIDE COORDINATED SHOP DRAWINGS PFJDR TO FABRICATION AND INSTALLATION. 8. MECHANICAL EQUIPMENT SHALL NOT BE USED FOR TEMPORARY HEAT DURING CONSTRUCTION. 9. VERIFY EXISTING CONDITIONS BEFORE COMMENCING ANY WORK ON AN DUSTING MECHANICAL SYSTEM. 10. ALL DUCTWORK SIZES SHOWN ARE INSIDE CLEAR. ADD APPROPRIATE DUMION FOR INSULATION OR DUCT LINER TO OBTAIN `TOTAL' DUCT SIZE 11. Ii+LSTALL COMBINATION RWSMOKE DAMPERS AT ALL LOCATIONS WHERE DUCTS PENETRATE FIRE RATED WALLS. DAMPER FIE RATING SHALL BE 1-1/2 HOUR UNLESS NOTED OTHERWISE COORDINATE DAMPER ACCESS WiTH GENERAL CONTRACTOR AND ELECTRICAL CONNECTIONS WITH ELECTRK:A. CONTRACTOR. 12 REFER TO ARCHITECTURAL REFLECTED CEILING PLANS AND ELEVATIONS FOR EXACT LOICATiON RE ALL DIFFUSERS AND GRILLES. PROVIDE SEPARATE COLING DIFFUSER SHOP DRAWINGS FOR APPROVAL 13. MAXIMUM FLEX DUCT LENGTH SHALL BE 6'-0' WiTH 0.5 x DUCT DIAMETER OFFSET, UNLESS NOW OTHERWISE. 14. PROVIDE REMOTE ACTUATED DAMPERS FOR ALL VOLUME DAMPERS OVER INACCESSIBLE CEILINGS AND SOFFITS. REFER TO ARCHITECTURAL DRAWINGS FOR CEILING TYPES. 15. PROVIDE TRANSITIONS AS REQUIRED TO CONNECT DUCTWORK TO AIR TERMINAL. UMTS. FANS, ANO OTHER MECHANICAL EQUIPMENT. 16. PROVIDE DIFFUSER AND GRILLE FRAMES COMPATIBLE WiTH ARCHITECTURAL COLING TYPE REFER TO ARCHITECTURAL REFLECTED COLING PLANS FOR CEE ING TYPE 17. COORDINATE EXACT LOCATIONS OF ALL ROOM THERMOSTATS AND/OR ROOM TEMPERATURE SENSORS WITH ARCHITECT PRIOR TO: INSTALLATION. PROVIDE A THERMOSTAT LOCATION SHOP DRAWING FOR APPROVAL MOUNT WALL THERMOSTATS AT 48' A.F.F. 18. PROVIDE A VOLUME DAMPER FOR EACH SUPPLY, RETURN, AND EXHAUST OPENING AND IN BRANCHES WHERE THREE OR MORE OPENINGS ARE ASSOCIATE) WiTH THE BRANCH AND ELSEWHERE AS NOTED ON THE DRAWINGS OR SPECIFICATIONS. 19. COORDINATE EXACT LOCATIONS OF MOUNTING HEIGHTS OF ALL PLUMBING FIXTURES WITH CASEWORK AND ARCHITECTURAL. DRAWINGS. 20. PROVIDE HJT -OFF AND CHIECK VALVES ON EACH HOT AND COLD WATER SUPPLY TO MOQNG VALVES. 21. STRUCTURAL CALCULATIORS FOR ALL MECHANICAL EQUIPMENT WEIGHTING 400 LBS OR MORE SHALL. BE PROVIDED AS PART OF THE PERMIT SUBMITTAL TO THE CITY. STRUCTURAL. CALCULATIONS SHWA. BE SIGNED AND SEALED BY A WASHINGTON STATE REGISTERED STRUCTURAL ENGINEER, FOR APPROVAL BY THE AHJ. 22. BUILDING STANDARD MATERIALS, EQUIPMENT, AND FIXTURES SHAM. BE USED ON ALL TENANT IMPROVEMENTS WITHOUT EXCEPTION. CONTRACTOR SHALL COMPLY WITH ALL APPUCABLE TENANT GUIDELINES AND STANDARDS. VICINITY MAP /LEGAL DESCRIPTION MECHANICAL INDEX OF DRAWINGS SHEET # DESCRIPTION SCALE MO.01 LEGEND NTS M1.01 MECHANICAL SCHEDULES NTS M1.02 STRUCTURAL CALCULATIONS NTS M1.03 STRUCTURAL CALCULATIONS NTS MD2.01 LEVEL 1 MECHANICAL DEMO PLAN 1/4'4-0° MD2.02 LEVEL 2 MECHANICAL DEMO PLAN MP2.OB LEVEL B MECHANICAL PIPING PLAN 1/4'4-0" M2.01 LEVEL 1 MECHANICAL PLAN 1/4°4-0° MP2.01 LEVEL 1 MECHANICAL PIPING PLAN 1/4-4-0- M2.02 LEVEL 2 MECHANICAL PLAN & CONTROLS 1/4°44" MP2.02 LEVEL 2 MECHANICAL PIPING PLAN 1/4°44 j REVIEWED FOR CODE COMPLIANCE APPROVED OCT 12 2.06 /k -,Ti � Clfy of Tukv414a DUiLDING DIVISION RECEIVED CITY OF TUKWILA► OCT 04 2016 PERMIT CENTER Legal: THIS DRAWING AND THE DESIGN HEREIN ARE THE PROPERTY OF UNIVERSITY MECHANICAL CONTRACTORS, INC. FOR THEIR USE IN CONSTRUCTION OF THIS PROJECT. NO OTHER USE SHALL BE PERMITTED WITHOUT THE WRITTEN CONSENT OF UNIVERSITY MECHANICAL CONTRACTORS, INC. V O ail 41 N � N O (3 a� 0 a� I -- w cn I-- LU n.. ai O 0) <C 00 0 z o T U. -100 o o x Q O LL U3 z d O pc o WN W< 0 o = LAJ o rn C n9 Ima o O N rn� O) N CO(O 0 0 " CN� (� 0 C X C- 0- L� (� J U-) N (� c (A z gee Q) O) a 9z UJ 0 r�UZ a W O m �a; ' �� 11 E U Z E w 3 WNEW3 a� i= OPS" V � �O of WAsy,� A C0 V Q a I �FGIST ERGO SSAONAL E� 09/26/2016 Drawn By KH Checked By RK Original Issue Date 08/24/16 Job No. 6880 Scale AS SHOWN Sheet No.. M0,01 AHU DESIGNATION AHU-01 SYSTEM CORRIDOR 104 CITY SUPPLY FAN MANUF. MODEL NUMBER CD I I MKIN LAHOOSA I 1,8DO 1 1.0 1 2,151 1 1.1 1 3 NOTES: 1. OJTSIDE AIR DUCTS SERVING INDIVIDUAL WRY AIR UNITS WITH LESS THAN 2,800 CM TOTAL SUPPLY ONLY NEED R-7 WWTION. 2. NOT REQUIRED IN UNHEATED EQUIPMENT ROOMS WITH COMBUSTION AIR LOUVERS PROVIDED THE ROOM IS ISOM FROM CONDITIONIED SPACE WITH R -I I INSULATION. I RMTE BETWEEN EXTERIOR ENVELOPE (WALL OR ROOF PENETRATION) AND ISOLATION MR 4. MINIMUM R -VALUE FOR GUM AIR DUCTS IS SAME AS FOR METAL FRAMED WALL PER TABLE C402.11. R-18 MEETS 1HIS EXTERIOR WALL REMIENT FOR CIMTE ZOO 4 AND 5. KING COUNTY IS 70NE 4C. USE R-21 FOR ZONE 6: FERRY, WNW, PEND OREILLF, AND STEVENS COUNTIES. 5 INSULATION NOT REQUIRED FOR MM WITHIN EQUIPMENT 6. FOR EXAMPLE, ABOVE CEILING PLENUMS WITH DUCTED MURN ARE CONSIDERED UNCONDITIONED SPACE; WVX MH DESIGN TEMPERATURE DIFFBEI'm BETWEEN THE INTERIOR AND EXTERIOR OF THE DUCT OR PLENUM DOES NOT EXCEED 15 F, NO INSULATION IS REQUIRED. 7. INSULATION FOR PLENUMS MALL BE THE SAME AS MOVE FOR DUCTS, DEPENDING ON SMVICE. REFER TO OUTSIDE AR MY, REM OR BMW SERVICE. B. PROVIDE ALL SERVICE ME FOR ALL DUCTS, EXCEPT PROVIDE WEATHERPROOF ALUMINUM YW FOR DUCTS OUTSIDE THE BUILDING. 9. PROVIDE VAPOR -RETARDER MASTIC ON SUPPLY AIR AND OUTSIDE AIR DUCTS 0 PLENUMS. 10. MURN AIR PLENUMS WITH PERMANENT OPENINGS TO CONMED SPACE ARE CONSIDEREI) CONDONED SPACE. CHILLED WATER AIR HANDLING UNIT SCHEDULE SCHEDULE 2' And Smaller DESIGNATION SERVICE LOCAON RETURN FAN HYDRONIC COOLING HYDRONIC HEATING COIL FINAL AIR FILTER P.D. = - (IN. WG.) !Q =E w =E INTERNAL VIBRATION ISOLATION ELECTRICAL DATA Ea C= w -Lr, ut =E c> cJ. MOTOR WEIGHT OPERATING WEIGHT (LBS) UFE. SAFETY EMERGENCY CONTROL rX. M Ce 9- MAT LAT CAPACITY U> E !T- �-=. g� Br- :2� cl: I COOK 135SQN-HP MAT [AT CAPACITY 2082 0.86 460/3 119 Q= cD R-6 BASE ISOLATION Z m m :t: m cz� �1_ m m m <55 OR >105 R-3.3 FIBERGLASS w �i I = 11 c_� - R_ : NONE NA <15 VrfFE Z 3 A3 80 65 55.2 53.9 59.7 48.9 12 45 55.1 0.21 8.00 346,8 35.0 85.5 1 99.9 17 120 108 0.11 3.90 M6.8 4- 286.2 0.2 0.4 1z MEW 8 DOWNSTREAM OF DAMPER [31 ALL R-18 [41 FIBERGLASS 460/3 MCD MOD CORE x LAY -IN ,COMPLIANT WITH 2012 WA STATE ENERGY CODE, COMMERCIAL PROVISIONS (WSEC) AND 2012 SEATTLE COMMERCIAL ENERGY CODE (SCEC) WITH UPDATES THROUGH 2015. 575.2 16X16 700 1 14 19 FdITE Z 3 AB can DIFFUSER TITUS In MW COE Sim LAY -IN BORDER TYPE 3 24x24 2OX20 1400 16 30-- VfUE Z 3 1-1/2' 2 - 00 LL.j (A Z M CHILLED WATER [4] Bi LWAR SUPPLY SLOT DIFFUSER Tam TBO-30 I -SLOT. I`W Ek Sim LAY -IN EDGE T -M 4FT LONG X 2* WIDE 6-1,4 X 5-1/4 OVAL 100 6 20 MiITE NOTES: 1. OJTSIDE AIR DUCTS SERVING INDIVIDUAL WRY AIR UNITS WITH LESS THAN 2,800 CM TOTAL SUPPLY ONLY NEED R-7 WWTION. 2. NOT REQUIRED IN UNHEATED EQUIPMENT ROOMS WITH COMBUSTION AIR LOUVERS PROVIDED THE ROOM IS ISOM FROM CONDITIONIED SPACE WITH R -I I INSULATION. I RMTE BETWEEN EXTERIOR ENVELOPE (WALL OR ROOF PENETRATION) AND ISOLATION MR 4. MINIMUM R -VALUE FOR GUM AIR DUCTS IS SAME AS FOR METAL FRAMED WALL PER TABLE C402.11. R-18 MEETS 1HIS EXTERIOR WALL REMIENT FOR CIMTE ZOO 4 AND 5. KING COUNTY IS 70NE 4C. USE R-21 FOR ZONE 6: FERRY, WNW, PEND OREILLF, AND STEVENS COUNTIES. 5 INSULATION NOT REQUIRED FOR MM WITHIN EQUIPMENT 6. FOR EXAMPLE, ABOVE CEILING PLENUMS WITH DUCTED MURN ARE CONSIDERED UNCONDITIONED SPACE; WVX MH DESIGN TEMPERATURE DIFFBEI'm BETWEEN THE INTERIOR AND EXTERIOR OF THE DUCT OR PLENUM DOES NOT EXCEED 15 F, NO INSULATION IS REQUIRED. 7. INSULATION FOR PLENUMS MALL BE THE SAME AS MOVE FOR DUCTS, DEPENDING ON SMVICE. REFER TO OUTSIDE AR MY, REM OR BMW SERVICE. B. PROVIDE ALL SERVICE ME FOR ALL DUCTS, EXCEPT PROVIDE WEATHERPROOF ALUMINUM YW FOR DUCTS OUTSIDE THE BUILDING. 9. PROVIDE VAPOR -RETARDER MASTIC ON SUPPLY AIR AND OUTSIDE AIR DUCTS 0 PLENUMS. 10. MURN AIR PLENUMS WITH PERMANENT OPENINGS TO CONMED SPACE ARE CONSIDEREI) CONDONED SPACE. FAN SCHEDULE SCHEDULE 2' And Smaller DESIGNATION SERVICE LOCAON NUMBER OF UNITS MANUFACTURER MODEL NUMBER (GREENHECK BASIS OF DESIGN) TYPE OPERATING CFM ESP (IN WG) RPM MOTOR WEIGHT TENANT EMERGENCY POWER UFE. SAFETY EMERGENCY CONTROL NOTES BHP VOLTAGE/ 'PHASE DISC. BY EC COMBO STARTER BY EC VFD BY MC (LBS) EF -1 RESTROOM DRUST FAN LEVEL I I COOK 135SQN-HP CENTRIFUGAL INLINE 1,300 2 2082 0.86 460/3 119 ALL R-6 FIBERGLASS X OUTSIDE THE BUILDING ALL R-8 FIBERGLASS TIM CONDITIONED SPACE <55 OR >105 R-3.3 FIBERGLASS BED TYPE 3 CONDITIONED SPACE 55-105 NONE NA <15 VrfFE Z 3 A3 COLN DIFFUSER REIURN AIR [5,61 NOTES: ALL R-6 [6] FIBERGIASS NOTES: 1. OJTSIDE AIR DUCTS SERVING INDIVIDUAL WRY AIR UNITS WITH LESS THAN 2,800 CM TOTAL SUPPLY ONLY NEED R-7 WWTION. 2. NOT REQUIRED IN UNHEATED EQUIPMENT ROOMS WITH COMBUSTION AIR LOUVERS PROVIDED THE ROOM IS ISOM FROM CONDITIONIED SPACE WITH R -I I INSULATION. I RMTE BETWEEN EXTERIOR ENVELOPE (WALL OR ROOF PENETRATION) AND ISOLATION MR 4. MINIMUM R -VALUE FOR GUM AIR DUCTS IS SAME AS FOR METAL FRAMED WALL PER TABLE C402.11. R-18 MEETS 1HIS EXTERIOR WALL REMIENT FOR CIMTE ZOO 4 AND 5. KING COUNTY IS 70NE 4C. USE R-21 FOR ZONE 6: FERRY, WNW, PEND OREILLF, AND STEVENS COUNTIES. 5 INSULATION NOT REQUIRED FOR MM WITHIN EQUIPMENT 6. FOR EXAMPLE, ABOVE CEILING PLENUMS WITH DUCTED MURN ARE CONSIDERED UNCONDITIONED SPACE; WVX MH DESIGN TEMPERATURE DIFFBEI'm BETWEEN THE INTERIOR AND EXTERIOR OF THE DUCT OR PLENUM DOES NOT EXCEED 15 F, NO INSULATION IS REQUIRED. 7. INSULATION FOR PLENUMS MALL BE THE SAME AS MOVE FOR DUCTS, DEPENDING ON SMVICE. REFER TO OUTSIDE AR MY, REM OR BMW SERVICE. B. PROVIDE ALL SERVICE ME FOR ALL DUCTS, EXCEPT PROVIDE WEATHERPROOF ALUMINUM YW FOR DUCTS OUTSIDE THE BUILDING. 9. PROVIDE VAPOR -RETARDER MASTIC ON SUPPLY AIR AND OUTSIDE AIR DUCTS 0 PLENUMS. 10. MURN AIR PLENUMS WITH PERMANENT OPENINGS TO CONMED SPACE ARE CONSIDEREI) CONDONED SPACE. DUCT INSULATION SCHEDULE 2' And Smaller ThL 2-1 L2 o" DUCT TYPE [7,8] LOCATION TEMP RANGE (DEGREES F) INSULATION R -VALUE REQUIREMENT INSULATION TYPE Pipe. Sch 40 Blk A530 ERW (Up to 101, Pipe, Sid Wt Blk A539 ERW (12' And. Larger) JOINT TYPE Swt - Leod-Free Solder, Silvabride 100 EQUIP. 0) NO. sow OUTSIDE AIR [1,2,91 UPSTREAM OF DAMPER [3] ALL R-18 [41 FIBERGLASS FRAME MODE DOWNSTREAM OF DAMPER, UNCONDITIONED SPACE ALL R-6 FIBERGLASS NC DOWNSTREAM OF DAMPER, CONDITIONED SPACE ALL R-8 FIBERGLASS TITUS NCO MOD CORE STEEL LAY -IN SUPPLY AIR [5,6,9] UNCONDITIONED SPACE ALL R-6 FIBERGLASS <15 OUTSIDE THE BUILDING ALL R-8 FIBERGLASS TIM CONDITIONED SPACE <55 OR >105 R-3.3 FIBERGLASS BED TYPE 3 CONDITIONED SPACE 55-105 NONE NA <15 VrfFE Z 3 A3 COLN DIFFUSER REIURN AIR [5,61 UNCONDITIONED SPACE ALL R-6 [6] FIBERGIASS BUM TYPE 3 CONDITIONED SPACE NA NONE [10] NA <15 OLffSIDE THE BUILDING ALL R-8 FIBERGLASS TIM MCD IN CORE STEEL LAY -IN OMST AIR UPSTREAM OF DAMPER ALL NONE 1z 18 DOWNSTREAM OF DAMPER [31 ALL R-18 [41 FIBERGLASS TITUS MCD MOD CORE Sim LAY -IN ,COMPLIANT WITH 2012 WA STATE ENERGY CODE, COMMERCIAL PROVISIONS (WSEC) AND 2012 SEATTLE COMMERCIAL ENERGY CODE (SCEC) WITH UPDATES THROUGH 2015. 24x24 NOTES: 1. OJTSIDE AIR DUCTS SERVING INDIVIDUAL WRY AIR UNITS WITH LESS THAN 2,800 CM TOTAL SUPPLY ONLY NEED R-7 WWTION. 2. NOT REQUIRED IN UNHEATED EQUIPMENT ROOMS WITH COMBUSTION AIR LOUVERS PROVIDED THE ROOM IS ISOM FROM CONDITIONIED SPACE WITH R -I I INSULATION. I RMTE BETWEEN EXTERIOR ENVELOPE (WALL OR ROOF PENETRATION) AND ISOLATION MR 4. MINIMUM R -VALUE FOR GUM AIR DUCTS IS SAME AS FOR METAL FRAMED WALL PER TABLE C402.11. R-18 MEETS 1HIS EXTERIOR WALL REMIENT FOR CIMTE ZOO 4 AND 5. KING COUNTY IS 70NE 4C. USE R-21 FOR ZONE 6: FERRY, WNW, PEND OREILLF, AND STEVENS COUNTIES. 5 INSULATION NOT REQUIRED FOR MM WITHIN EQUIPMENT 6. FOR EXAMPLE, ABOVE CEILING PLENUMS WITH DUCTED MURN ARE CONSIDERED UNCONDITIONED SPACE; WVX MH DESIGN TEMPERATURE DIFFBEI'm BETWEEN THE INTERIOR AND EXTERIOR OF THE DUCT OR PLENUM DOES NOT EXCEED 15 F, NO INSULATION IS REQUIRED. 7. INSULATION FOR PLENUMS MALL BE THE SAME AS MOVE FOR DUCTS, DEPENDING ON SMVICE. REFER TO OUTSIDE AR MY, REM OR BMW SERVICE. B. PROVIDE ALL SERVICE ME FOR ALL DUCTS, EXCEPT PROVIDE WEATHERPROOF ALUMINUM YW FOR DUCTS OUTSIDE THE BUILDING. 9. PROVIDE VAPOR -RETARDER MASTIC ON SUPPLY AIR AND OUTSIDE AIR DUCTS 0 PLENUMS. 10. MURN AIR PLENUMS WITH PERMANENT OPENINGS TO CONMED SPACE ARE CONSIDEREI) CONDONED SPACE. PIPE INSULATION SCHEDULE CHILLED WATER SUPPLY AND RETURN ITEMS 2' And Smaller ThL 2-1 L2 o" GRILLE, REGISTER AND DIFFUSER SCHEDULE INSULATION TYPE VAPOR BARRIER REQUIRED? PIPE MATERIALS Pipe, Copper Type L B88 Pipe. Sch 40 Blk A530 ERW (Up to 101, Pipe, Sid Wt Blk A539 ERW (12' And. Larger) JOINT TYPE Swt - Leod-Free Solder, Silvabride 100 EQUIP. 0) NO. sow MANUFACRW I%& STYLE MATERk FRAME FRAME MODE DESCRIPTION FACE SEE NECI( S[ZE UAX 99 Raw NC COLOR NOTES At CEILING DIFFUSER TITUS NCO MOD CORE STEEL LAY -IN BORDER TYPE 3 24x24 W 100 6 <15 ViITE Z 3 A2 CEILING DIFFUSER TIM Mco MOD CORE STEEL LAY -111 BED TYPE 3 24x24 1OXIO 210 8 <15 VrfFE Z 3 A3 COLN DIFFUSER TITUS MCD I% CORE Sim LAY -11 BUM TYPE 3 24x24 12X12 375 10 <15 WHffE Z 3 A4 CUM DIFFUSER TIM MCD IN CORE STEEL LAY -IN BUM TYPE3 24)Q4 1014 550 1z 18 M. 2.3 A5 CEILING DIFFUSER TITUS MCD MOD CORE Sim LAY -IN BORDER TYPE 3 24x24 16X16 700 1 14 19 FdITE Z 3 AB can DIFFUSER TITUS In MW COE Sim LAY -IN BORDER TYPE 3 24x24 2OX20 1400 16 30-- VfUE Z 3 1-1/2' 2 - 00 LL.j (A Z M CHILLED WATER [4] Bi LWAR SUPPLY SLOT DIFFUSER Tam TBO-30 I -SLOT. I`W Ek Sim LAY -IN EDGE T -M 4FT LONG X 2* WIDE 6-1,4 X 5-1/4 OVAL 100 6 20 MiITE 4 B2 LINEAR MY SLOT DIFFUSER TITUS ED -30 2 -SLOT, I -W EL STEEL LAY -IN EDGE T -BARS 4Ff LONG X 4* WIDE 9-318 X 5-1/4 OVAL 210 8 23 WHITE 4 83 UTAR SURKY SLOT DIFFUSER TITUS TBO-30 3 -SLOT, I' W Ek STEEL LAY -IN EDGE T -BARS 41`17 LONG X C WIDE 12-1/2 X 5�1/4 OVAL 32D to 25 WHITE 4 B4 LINEAR SLMY SLOT DIFFUSER TIM TBD -30 4 -SLOT, 1-W Ek Sim LAY -IN EDGE T -BARS 4Fr LONG X 8' WIDE 15-5t8 X 5-1/4 OVAL 425 12 26 WHITE 4 2-1/2' 2-1/2' 3. 3. 1 C1 RETM GRILLE TITUS 5OF EGGCRATE ALUMINUM LAY -IN BOW TYPE 1 2402 22XIO 600 PER PLAN <12 MfTE 1.2 C2 RETURN GRILLE TITUS 5OF EGGCRATE ALLIMINUM LAY -IN BORDER TYPEI 24x24 M 1200 PER PLAN <12 Mff 1,2 C3 RETM GRILLE THUS 5OF EGGCRATE ALUMINUM LAY -IN BUM TYPE I 24x48 22X46 2400 PER PLAN <12 Wiff 1, 2 C4 RETURN GRILLE TITUS 5OF EGGCFATE ALUMINUM SURFACE BORDER TYPE 3 2644 2012 ISDO PER PLAN <12 M 1,2 NO F 3' 4* 4-1/2' 4-1/2' 4-1/2* DI OHM GRILLE TITLIS 35ORL SINGLE DEF Sim SURFACE BOW TYPE I 10XIO 300 100 6 <10 3' 3- D2 DMIST GRILLE TIM Y)ORIL SINGLE DEF I Sim SURFACE BORDER TYPE1 1 12X12 1OXIO 210 8 <10 D3 MIAUST GRILLE TITUS I 35ORL SINGLE DEF Sim 11"111 BORDER TYPE 1 1014 I= 375 10 10 *UE D4 MKIST gaff TITUS 3M SINGLE DEF STEEL SURFACE BOW TYPE I I6X16 :J 1014 550 12 27 WIM ALL 0.20 - 0.26 75 ELASTOMERIC YES H 1/2' [6] 1/2' [6] NOTES* 1. PROVIDE RENLIM CAN FOR DUCTED SYSIEM IN CEILING APPLICATION (NOT EQUIRED FOR SIDEN.L APPLICATION); OR PROVIDE SOUND BOOT 9 N)ICATED ON PLANS. 2. DffUSER OR GRILLE MAY ALSO BE USED FOR HARDLID APPLICATIONS WtIERE A TITUS `TRM' RAM MOUNT FRAME IS MM, FRAME AS INDICATED ON RAE TRY PROVE ACCESS ABOVE CMN. 3. FOR LIMITED CEILING HMff APPLICATIONS, PROVIDE PLENUM CAN WITH BRANCH DUCT SIZED SIDE RLT, OMWtSE PROVIDE SQUARE TO ROUND TIRNNSITION WITH BRANCH DUCT SIZED TOP HE 4. FACTORY INSULATED PLENUM CAN PROVIDED WITH DIFFUSER COMPLIANT WITH 2012 WA STATE ENERGY CODEJ COMMERCIAL PROVISIONS (WSEC) AND 2012 SEATTLE COMME PIPE INSULATION SCHEDULE CHILLED WATER SUPPLY AND RETURN ITEMS 2' And Smaller ThL 2-1 L2 o" MEAN RATNG TEMP (DEGREES 0 INSULATION TYPE VAPOR BARRIER REQUIRED? PIPE MATERIALS Pipe, Copper Type L B88 Pipe. Sch 40 Blk A530 ERW (Up to 101, Pipe, Sid Wt Blk A539 ERW (12' And. Larger) JOINT TYPE Swt - Leod-Free Solder, Silvabride 100 9W FITTING MATERIAL Wrot Copper B16.22 Std Wt A234 WPB B16.9 BRANCH TAKEOFF Threod-O-Let, 30001 FS Blk, T -Drill Type 2 Bronchlet, Std Wt A106B SMLS FLANGES 1501 Swt Companion Flange, Cost Bronze 016.24 1501 WN Flange, A105 Std Wt B16.5 GASKETS Gasket. 1/8' Non -Asbestos Ring, B16.21 Gasket, 1/8' Non -Asbestos Ring, B16.21 BOLT TYPE Bolts, A307 Grade B Plated Bolts, A307 Grade B Plated DOMESTIC COLD NON -POTABLE COLD ALL 0.21 - 0.27 VALVES FIBERGLASS YES [11] BALL VALVES: SWT 1501 Boll Valve, Two -Piece Full Port SP -110 Bmz Swt - Nibco S-585-70 N/A Ir 1-1/2* GATE VALVES: THD FLG N/A 1251 Gate Valve, Bolted Bonnet OS&Y Solid Wedge SP -70 Cl Aq - Nibco F-617-0 (Exclude From Fill) Uj GLOBE VALVES: THO / FLG 1251 Globe Valve, Screw-in Bonnet Integral Seat SP -80 Bmz Thd - Nibco T -211-Y 1251 Globe Valve, Bolted Bonnet SP -85 Cl ng - Nibco F -718-B BUITERFLY VALVES: LUG NIA 2001 Butterfly Valve, SP -67 DI Lug Style - Nibco LD-2DOO (Up to 121 105-140 0.21 - 0.28 1501 Butterfly Valve, SP -67 DI Lug Style - Nibco LD -1000 (14! And Larger) FIBERGLASS NO SWING CHECK VALVES: THD FLG 1251 Check Valve, Horizontal SWing Y-Pottem SP -80 Bmz Thd - Nibco T -413-B 1251 Check Valve, Horizontal Swing Bolted Bonnet SP -71 Ci Ag - Nbico F -918-B 1-1/2' 1-1/2' C:) (0 (Z) C14 N -S WAFER CHECK: 1251 Ring Check Valve, Inline Lift Spring Actuated Bmz Thd - Nibco T-480 1251 Check Valve, Wafer Sye Spring Actuated SP -125 Ct - Nibco W-910 COY')) F4 < CIRCUIT BAL VALVE. THD / FLG 3001 Circuit Balancing Valve, Y- Pattern Bmz Thd - TA Hydronics 787 1251 Circuit Balancing Valve, Y- Pattern 01 Ag - TA Hydronics 788 to n SPECIALTIES STORM DRAIN ALL DIELECTRIC WATERWAYS Dielectric Nipple, Bmz (LF) Thd x Thd - Victoulic 647 -TT N/A PRESSURE RELIEF Pressure Relief Valve, CS Thd - Kunkle 910 Pressure Relief Valve, CS Thd - Kunkle 910 STRAINER, Y -PATTERN 1251 Strainer, Y -Pattern Bmz Thd - Mueller 351M 1251 Strainer, Y-Pattem Ct FIg - Mueller 758 PRESSURE GAUGE 0-1001 Pressure Gouge, Aluminum Case, Bmz Thd - Weiss 4PG-Nl Pressure Gauge, Aluminum Case, Bmz Thd - Weiss 4PG-Nl THERMOMEFER Thermometer, 9'Scale, 3-1/2' Stem, Variable Angle Thd - Weiss 9VU35-24O Thermometer, 9Scale, 3-1/2' Stem, Variable Angle Thd Weiss 9VU35-240 0 L2 HEATING WATER [4) HEATING WATER - LOW TEMP HEATING WATER - HIGH TEMP NOTES: 1 - Copper - Use 'Branch Takeoff* in lieu of fitting if branch piping is 1 sizes less than main or more. Example; Use 1-1/2* T-Dnll in lieu of 2'xl-1/2' Tee. 2 - Carbon Steel - Use *Branch Takeoff* in rieu of fitting if branch piping is 2 sizes less than main or more. Example; Use 2-1/1' shaped nipple (saddle) in lieu of 42-1/2" Tee. PIPE INSULATION SCHEDULE INSULATION SPEC PIPING SYSTEM TEMP RANGE (DEGREES F) CONDUCTIVITY BTU -IN/ (&Fr^2-0 MEAN RATNG TEMP (DEGREES 0 INSULATION TYPE VAPOR BARRIER REQUIRED? PIPE INSERT NOTE PIPE SIZE 1' TO <1 1/2' 1 11f To <4' 4' TO <8* 8*&oVER Z 00 C 0 1jL 00 0) DOMES11C COLD DOMESTIC COLD NON -POTABLE COLD ALL 0.21 - 0.27 75 FIBERGLASS YES [11] A 1/2' [6] 1/2' [61 Ir 1-1/2* La Uj 0 Uj < DOMESTIC HOT [1] DOMESTIC HOT NON -POTABLE HOT 105-140 0.21 - 0.28 100 FIBERGLASS NO 0 1-1/2' 1-1/2' 1-1/2' C:) (0 (Z) C14 COY')) F4 < to n STORM DRAIN [2,31 STORM DRAIN ALL 0.21 - 0.27 75 FIBERGLASS YES [111 B 1. 1. 1. 1. 1. 0 L2 HEATING WATER [4) HEATING WATER - LOW TEMP HEATING WATER - HIGH TEMP 105-140 141-200 0.21 - 0.28 0.25 - 0.29 100 125 FIBERGLASS FIBERGLASS NO NO C C 1. 1-1/2* 1. 1-1/2' 1-1/2' 2- 1-1/2* 2 1-1/2' 2 - 00 LL.j (A Z M CHILLED WATER [4] CHILLED NATER 40-60 0.21 - 0.27 75 FIBERGLASS YES D 1/2' [6] 1/2' [6] 1. 1. 1. E CONDENSER WATER [4,5] CONDENSEE WATER 40-60 0.21 - 0.27 75 FIBERGLASS YES [7] E 1/2' [6] 1/2' [6] 1. f 1. LU LOW PRESSURE STEAM STEAM - LOW PRESSURE 201-250 (0-151) 0.27 - 0.30 150 FIBERGLASS NO F 2-1/2' 2-1/2' 2-1/2' 3. 3. MED/HIGH PRESSURE STEAM STEAM - MED/HGH PRESSURE STEAM - HICH PRESS 251-350 (16-1201) >350 (>120P 0.29 - 0.32 0.32 - 0.34 200 250 FIBERGLASS FIBERGLASS NO NO F F 3- 4-1/2' 4' 5- 4-1/2' 5- 4-1/2' 51 4-1/2' 5 - STEAM CONDENSATE -LOW CONDENSATE - LON/MED TEMP <250 0.27 - 0.30 150 FIBERGLASS NO F 2-1/2' 2-1/2' 2-1/2' 3- 3 - STEAM CONDESTE-HIGH CONDENSATE - HIGH TENP >250 0.29 - 0.32 250 FIBERGLASS NO F 3' 4* 4-1/2' 4-1/2' 4-1/2* GENERATOR DRUST [8] GENERATOR DMUST UP TO 1100 0.45 300 CAL -SIL NO G 3' 3- 3- 3- 3 - REFRIGERATION [91 REFRIGERATIO11 SUCTION <40 0.20 - 0.26 75 ELASTOMERIC YES H 1/2' [6] 1. 1, 1, CONDENSATE DRAIN [10] COIL CONDENSATE DRAIN ALL 0.20 - 0.26 75 ELASTOMERIC YES H 1/2' [6] 1/2' [6] COMPLIANT WITH 2012 WA STATE ENERGY CODEJ COMMERCIAL PROVISIONS (WSEC) AND 2012 SEATTLE COMME ?CIAL ENERGY CODE (SCE� WITH UPDATES THROUGH 12015. 1 1 - I i NOTES: 1. MOM DOMESTIC HOT WATER RECIRCULATION PIPING. DO NOT USE RSERTS - INSUTE AROUND HMGER (INC STANDARD) 2. INSULATE ALL HORIZONTAL STORM DRAIN PIPING 16WO IN CONDITIM SPACE. DICULIDING PIPING FROM LOWER ROOFS AND DEOM MUTE ROOF DRAIN BODIES. (UMC SWIDARD) 3 INSULAEE FIRST 20 FEET OF HORIZONTAL OVERFLOW STORY DIRM PM INSIALLED IN CONDITIoNED SPACE, WJUE PIPING FROM WO ROOFS AND DECM INSLILATE ROOF DRAIN BODIES, (UMC STAN11%) t PIPING THAT 6 PART OF A HFATING OR COOLING SYSTEM ODNOM FWIDS BETWEEN 60 F RD 105 F DOES NOT REQUIRE INSULITION. (WSEC 2012) 5. IF DXSED CONDENSER WATER PIPING IS USED FOR HEM AND IS I]ETWEEN 60 F AND 105 F, NSULATE ALL MOVEI) PIPE 00 Wr NOT THE PIPE RUN - IN OCCUPIED AREAS ONLY. 6. MINIMUM TICIONESS OF 1/f IS REQUIRED of CODE FOR THIS PIPE SIZE. I- THU MULAE104 6 ALSO ACCEPIABLE AT NO ADDED COST IF PREFERRED BY SUBCONTRACTOR. 7. VAPOR BARRIER REQUIRED ONLY IF CONDENSER WATER IS 60 F OR BROW & GENERATOR OHM INSULATION IS FOR PERSONNEL PROTECTION - MWESS 6 NOT DRIVEN BY ENERGY CODE 9 VERIFY REQUIREMENTS FOR REFRIGERANT SUCTION LINES FOR EACH OLICAMI. to INSULATE COIL CONMISATE PIPING *01 LOCATED IN CONDITIONED SPACE OR ABOVE CMING OF COND7)ONE]) SPACE. It. IT IS ACCEPTABLE FOR HANGER TO PENETRATE VAPOR BMW AT TOP OF PIPE FOR COLD WER AND STORY DRAIN SI(STEMS. .......... .................. ... . .......... . 61111 .. .. ...... ... ,g Selection Info A ""I",""�"I",""""""""ll""IllI .............. ........... q 1? H/C/B CFM 3 50 401f AX B 1815 0 1� . ............ "I M 36 50 B 45 w� w W, 0 0 4 140", 50 8 45 p 8 5 U 115 50 tiz 52 0 All".," V 7V 50 a 176 50 B 176 0 "',"'a, M - ....... . .. 195 "", . . ... ..... 0 195 mw 0 Peak Totals 24,645 5,194 1,121 1,121 1 29,375 0 1,815 29,375 F_ 2.433 7 - PEAK OSA MAX % IN % IN % MAX % MAX % MAX % hN % IS REVIEWED FOR OCT 12 2016 QtV Of Tutwila U1 _112ING DIVISION RECEIVED CITY OF TUKWILA NOTES Lego 1: UNIVERSITY MECHANICAL CONTRACTORS, INC. FOR THEIR USE IN CONSTRUCTION OF THIS PROJECT. NO OTHER USE SHALL BE PERMITTED WITHOUT THE WRITTEN CONSENT OF UNIVERSITY MECHANICAL CONTRACTORS, INC. 1.0 Q) V_ _+1 0 0 CN 0, LU LU Q_ (3 U) o <<<<<<< i /()NAI- 'V�� Drawn By KH Checked By RK I I e a e Job No. 6880 Sheet No. M101 Z cl) 0 Z 00 C 0 1jL 00 0) L_ E X LL Uj Z< 0 0 Ir La Uj 0 Uj < Uj 0 L_ Lu -00 0 C: 3. a_ 0 C:) (0 (Z) C14 COY')) F4 < to n Lij C�l CD C14 04 F_ 0 L2 LU F_ CD Lr) 0 j cc r- �C,4 Z 00 LL.j (A Z M LLJ Uj r >, Z Z Uj 0 E 0 < E LU i /()NAI- 'V�� Drawn By KH Checked By RK I I e a e Job No. 6880 Sheet No. M101 1/2" DIA HILTI KWIK BOLT TZ, (E) 3" CONC OVER 3" MTL EMBED 3 5/8' TYP DECK (TYPE W) Attachment to Structural Steel 4' Min. P2785 0-16 8earn Clamp -------------------------------- --- — — — — — — — — MECH UNIT 0 Pi 000 UNISTRUT P1000 BRACING PER PLAN 3" MIN i 3° MIN PSO10 Hut vrith 45 Max. 4 :: HHcs HHCS 1/2' DIA .----- \ UNISTRUT P1000T P1843w Hinge VIBRATION ISOLATOR (BY OTHERS) P1000 Transverse or `' r Longitudinal Brace L3X3X1/4"' UNIT SUPPORT 1/2" DIA THREADED ROD C3X6 UNIT SUPPORT MAX SEISMIC BRACING TO EXISTING STEEL BEAM SEISMIC BRACING TO UNIT SUPPORT ANGLE Drawing By unistrut NTS NTS THREADED ROD TO EXISTING CONCRETE OVER MTL DECK NTS 1 CRITERIA 1. ALL MATERIALS, WORKMANSHIP, DESIGN, AND CONSTRUCTION SHALL CONFORM TO THE DRAWINGS, SPECIFICATIONS, AND THE 2012 SEATTLE BUILDING CODE. 2. DESIGN LOADING CRITERIA: a , MECHANICAL UNITS . . . . . . . . . . WEIGHTS FURNISHED BY MANUFACTURER ........ ............. I j N EARTHQUAKE ANALYSIS PROCEDURE: NONSTRUCTURAL COMPONENT DESIGN Spring Isolators SITE CLASS=D, SS=1.512, Sds=1.01, S1=0.58, SD1=0.58 SDC D, IP=1.0, RP=6.0, Ap 2.5 �— ANCHOR PER DETAIL 1/S1.0,TYP _ 19 t SEE PLANS FOR ADDITIONAL LOADING CRITERIA r (E) W1 8X40 3. CONTRACTOR SHALL BE RESPONSIBLE FOR ALL SAFETY PRECAUTIONS AND THE ! METHODS, TECHNIQUES, SEQUENCES OR PROCEDURES REQUIRED TO PERFORM THE 1/2' DIA THREADED ROD,TYP SUSPENDED CONTRACTORS WORK. THE STRUCTURAL ENGINEER HAS NO OVERALL SUPERVISORY MECHAMCALIUNIT; i AUTHORITY OR ACTUAL AND/OR DIRECT RESPONSIBILITY FOR THE SPECIFIC WORKING i CONDITIONS AT THE SITE AND/OR FOR ANY HAZARDS RESULTING FROM THE ACTIONS _ 8OOLEIS :MAXWEIGF(f OF ANY TRADE CONTRACTOR. THE STRUCTURAL ENGINEER HAS NO DUTY TO INSPECT, M P1aaa SUPERVISE, NOTE, CORRECT, OR REPORT ANY HEALTH OR SAFETY DEFICIENCIES TO rr THE OWNER, CONTRACTORS, OR OTHER fiNTITIES OR PERSONS AT THE PROJECT SITE. w Q — - C3X6 v ;� ANCHORAGE i ; UNISTRUT P1000 BRACING PER PLAN TO C3 LU ± T ; (E) STEEL BEAMS PER 3/S1.0, TYP cxo v; ; x 3 i o ®� 4 X- _ i m t i v 4. EXPANSION BOLTS INTO CONCRETE AND CONCRETE MASONRY UNITS SHALL BE "KWIK r, " w w Ll C3X6 t J tv) .�– __________�_w�___ �._. _ . _ .. P1000 ._... BOLT TZ" AS MANUFACTURED BY THE HILTI CORP., INSTALLED IN sTRlcr � L3X3X1/4 _.: o,.: � ACCORDANCE WITH ICC -ES REPORT NO. ESR -1917, INCLUDING MINIMUM EMBEDMENT t� w REQUIREMENTS. BOLTS INTO CONCRETE MASONRY OR BRICK MASONRY UNITS SHALL BE INTO FULLY GROUTED CELLS. SUBSTITUTES PROPOSED BY CONTRACTOR SHALL BE 0 0c SUBMITTED FOR REVIEW WITH .ICC REPORTS INDICATING EQUIVALENT OR GREATER LOAD CAPACITIES. SPECIAL INSPECTION IS REQUIRED FOR ALL EXPANSION BOLT ? EXTEND L3X3 FOR SEISMIC BRACING AS REVD, Q W14X26 n INSTALLATION. CONNECT PER DETAIL 2/S1.0 STEEL 03X6 5. STRUCTURAL STEEL SHALL CONFORM TO THE FOLLOWING REQUIREMENTS: ` C channels are required on all units. On unit sizes 007 and above, L -channels Q W1 022 on both ends are also required. TYPE OF MEMBER ASTM SPECIFICATION- FY A. WIDE FLANGE SHAPES A992 50 KSI ( C B. OTHER SHAPES, PLATES, AND RODS A36 36 xsI MECHANICAL UNIT SUPPORT I TAMING C. OTHER SHAPES AND PLATES A572 (GRADE 50) 50 KSI y LEVEL 2 MECHANICAL UNIT SUPPORT FRAMING PLAN (NOTED GRADE 50 ON PLANS) Drawing from Manufacturer, With Added Info b 5SF NTS D. PIPE COLUMNS A53 (E OR S, GR.B) 35 KSI N i S. STRUCTURAL TUBING A500 (GR.B) OR ASTM A1085 y 1/4"=1'-0" -SQUARE OR RECTANGULAR 46 KSI -ROUND 42 KSI { s 1 0/EM IIMCWML GI 2t24 Third Avenue - Suite tao - Seattle, WA 98121 p: 2o6.443.62t2 ssfengineers.com - Copyright 2015 Swensm Say Fagg - AR Rights 9/21/2016 DRAWN: EBG DESIGN: EBG CHECKED: ABB APPROVED: ABB REVISIONS: DPO: PROJECT TIRE: MUSEUM OF FLIGHT RESTROOM EXPANSION MECHANICAL UNIT SUPPORT 9404 E MARGINAL WAY. S SEATTLE, INA 98108: ARCHITECT: SH..KSAR.CHITECT'S 1050 N.38th St, 5eaWe. WA 98103> r r 206 676,9151 :'ti't.'N?Siiic53fCt=tBC?S.CC'R - ISSUE: PERMIT ;HEFT TIRE: MECHANICAL UNIT. STRUCTURAL SUPPORT ;CALF: VARIES )ATE: 9/21/2016 IROJECT NO: 00099-2016-07 HEFT NO: S .0 10: OF SHEETS: ECEIVED CITY OF TUKWILA OCT 042016 MM I 157(o PERMIT CENTER REVIEWED FOR CODE COMPLIANCE APPROVED OCT 12 2016 City ©f Tukwila BUILDING DIVISION Legal: THIS DRAWING AND THE DESIGN HEREIN ARE THE PROPERTY OF UNIVERSITY MECHANICAL CONTRACTORS, INC. FOR THEIR USE IN CONSTRUCTION OF THIS PROJECT. NO OTHER USE SHALL BE PERMITTED WITHOUT THE WRITTEN CONSENT OF UNIVERSITY MECHANICAL CONTRACTORS, INC. F— W u'1 Cie H W CL 6 N o z 0000000 Drawn By C Checked By RK Original Issue Date 4� �Z Job No. 6880 Scale V Z ' c o J OC 0 x Z� LU a 0 0 .� N �W 0 0 W p �Q I— rW� Q) LU ami et W LL O o- o c::) (D O CV rn — cD cD M r� (D(D 4 0 X 0— LL_ w+ Ln J c00 CV Z OC O N 0 LL U O1 Z _O C CL V iWi�— Vis' J�,/ � t� m m 5 V/r� cD E 0 U ZD c 3 F.— 3 Cr) Q) Drawn By KH Checked By RK Original Issue Date 08/24/16 Job No. 6880 Scale AS SHOWN Sheet No. M1.02 W Structural Calculations for: Museum of Flight Restroom Expansion Mechanical Unit Support 5404 E Marginal Way S Seattle, WA 98108 9/21/2016 Prepared for: SHKS Architects Job #: 00099-2016-07 Date: September 21, 2016 59A B 21247trrdAve:bu e1G0.5. 7tzt t:Aa3}2i 0 206.44967f2 c',rirt3e is;c�r - 7itCOME4 X34Or. oad>"r;:y,..$u�:etL�O. T5K0'h4,lY`A.9$403 0 2�3.26q;1470 _Mechanical Unit Support Summary: New mechanical unit to be suspended below existing floor. Criteria: Existing Floor Live Load (Office) = 50psf + 15psf partitions Existing Floor Dead Load = 65 psf (3" NW Conc on 3" W3 Deck + 10psf misc.) Mechanical unit weights = 575lbs per Mechanical Drawings, add 225 lbs for frame/mise. Seismic= (see attached USGS ground motion parameters) Gravity Framing: Check existing concrete over metal deck with added unit weight: P P w I P = 200 lbs @ Third Pts w (super) = 65psf LL +10 psf DL (superimposed) n L= 10.5' Mmax=1734 ft -lbs 3" NW Over 20ga W3 Deck: Allowable Superimposed Load=150psf (single span) Mmax < M. equiv -> OK M,equivalent = 2067 ft-lbs/ft (E) Conc Deck is OK w/ Added Loading Seismic Bracing: Design for Fp = 0.4apSdsWp/(R/1) (1+2z/h) = 0.4(2.5)(1.01)Wp/(6/1.0)(1t2) = 0.51Wp Fp= 0.51Wp = 0.51(800lbs) = 408 lbs Max brace force = 300 lbs. P1000 Pa = -2200 lbs @ L= 6ft -> OK Model Axial (0.9D+E) Design 9r2016 Design Maps Srnmary Report MUM Design Maps Summary Report User -Specified Input Building Code Reference Document 2012/2015 International Building Code (which utilizes USGS hazard data available In 2008) Site Coordinates 47.529080N, 122.30491°W Site Soil Classification Site pass D - "Stiff Soil' Risk Category LWIII USGS-Provided Output Ss = 1.512 g Sas = 1.512 g Sos = 1.008 g S, = . 0.576 g S,4i = 0.864 g Sol = 0.576 g For information on how the SS and S1 values above have been calculated from probabilistic (risk -targeted) and deterministic ground motions in the direction of maximum horizontal response, please return to the application and select the '2009 NEHRP' building code reference document. MCE,L Response Spectrum Design Response Spectrum 1.36 1.10- 0.93 .10 0.93 aea - 1.12 an Os6 - a66 N a80 N 0.55 O.0 au 0.48 a33 0.22- 0.16-- .32 ai6 all 0.00 D.00 0.00 0.20 0.40 0.60 0.80 1.00 1.20 1.40 1.60 1.80 2.00 - 0.00 0.20 0.40 0.60 012 1.00 1.20 1.40 1.60 1.80 2.00 Period T (sac) Period, T (sect Although this information is a product of the U.S. Geological Survey, we provide no warranty, expressed or implied, as to the accuracy of the data contained therein. This tool is not a substitute for technical subject -matter knowledge. 2of4 hftNfehp2-oa-tquakewr.tsgs.gov/desigmapsAWsLimmaryptp7templats=mirtmal&lafiWdEF=47. 46G&loVWde=-12230490 lMl78 siWms=... 111 Technical Data Sheet for Destiny 001 Job Number. ZZCP2J Page Prepared Date: 3 ot8l`31/2016 Job Name: MUSEUM OF FLIGHT 14 of 17 www.DaikinApplied.com Ifiswidij-'C66ilijilibbrit Channel - iii 1 §$' 413 �§• • 9S 22.2 9S sem. i .915' '� 2 J� 233 T1 41.113 + 1 1 - .710' t 1 - 2 COLUMN LOADING - P1000 BEAM LOADING - P1000 Naifmam ; Bea. at 24 (610) ilfill cod JtilawitIle Load hlaiininm Cafama Load kirpiied at Haig#1 'at5lotEaca- :R 60 (1524) K=1,2 11.50 1118 2,230 9.50 24 . 24 3,450 10,750 9,900 8,770 7,730 36 3,050 8,910 7,730 6,370 5,280 48 2,660 7,250 .5,980 4,660 3,770 60 2,290 5,890 4,660 3,600 2,940 72 2,000 4,800 3,770 2,940 2,380 84 1,760 4,010 3,170 2,460 1,970 96 1,570 3,450 2,730 2,090 1,650 108 1,410 3,020 2,380 1,800 340 120 1,270 2,680 2,090 - •' BEAM LOADING - P1000 P1000 BRACE DESIGN LOAD 0n8t1ppnded Length : -. a ; Bea. at 24 (610) 4,200 hllmvable Uni(atmthittang Loadlant at 0e6eIlion 16.00 Spsn tlalfom# load "load Pon/1814: �anJ24(1 `, Spanl300 60 (1524) 2,650 11.50 72 (1829) 2,230 9.50 24 1,690 0.06. 1,690 1,690 1,690 36 1,130 0.13 1,130 1,130 900 48 850 0.22 850 760 510 60 680 0.35 650 490 320 72 560 0.50 450 340 220 84 480 0.68 330 250 170 96 420 0.89 250 190 130 108 380 1.13 200 150 100 120 340 1.40 160 120 80 144 280 2.01 110 80 60 168 240 2.74 80 60 40 192 210 3.57 60 50 NR 216 190 4.52 50 40 NR 240 170 5.58 40 NR NR P1000 BRACE DESIGN LOAD 0n8t1ppnded Length : -. Compression Load' to 24 (610) 4,200 18.50 36 (914) 3,650 16.00 48 (1219) 3,130 13.50 60 (1524) 2,650 11.50 72 (1829) 2,230 9.50 84 (2134) 1,850 8.00 96 (2438) 1,570 6.50 108 (2743) 1,360 6.00 120 (3048) 1,200 5.00 'Note: i. Maximum axial load under seismic loading conditions. 2- The design bad shall not exceed the allowable loads for connection detall, ��'�,'% ✓"''dY �4ittt S� 22 �� ��yd+,Yh.44g!N': i wTN REVIEWED FOR CODE COMPLIANCE APPROVED OCT 12 2016 City of Tukwila BUILDING DIVISION' RECEIVED CITY OF TUKWILA OCT 04 2016 PERMIT CENTER Legal: THIS DRAWING AND THE DESIGN HEREIN ARE THE PROPERTY OF UNIVERSITY MECHANICAL CONTRACTORS, INC.. FOR THEIR USE IN CONSTRUCTION OF THIS PROJECT. NO OTHER USE SHALL BE PERMITTED. WITHOUT. THE WRITTEN CONSENT OF UNIVERSITY MECHANICAL CONTRACTORS, INC. <<<<<<< N Drawn By KH Checked By RK Original Issue Date 08/24/16 Job No. 6880 Scale AS SHOWN Sheet No. M1.03 1` © to Q V Z 00 o n Olt �'�' OD 0 Z 0) L_ L W -- O (9Q it 0 U)Q Q) 2W Q 1.11 Q F �W1� O p L_ 0) C0 c 0 O cfl O N rn r - M N 1 1 d' r- r� r7 cOMcD O O C14 V C 0 X ♦/mo/�w Vd LO Ci) Z rJ Cr. r - N +00 U) O0 _r � COV CO Z U Cr) O C Cr. 4C Fr. U) V W ~ Z CF)� �o Q ui O ca V 5 V g� Z3 E U ZD 7 Cie 3 3: I-- 3 N Drawn By KH Checked By RK Original Issue Date 08/24/16 Job No. 6880 Scale AS SHOWN Sheet No. M1.03 u - cn w � 0 L� a N s� U cD � N — H — — G _ __-. — g — — A — UP CORRIDOR 109 — A Q DEMO ALL CEILING HVAC SYSTEMS THAT SERVE THE SPACE SHOWN FIELD VERIFY ROUTING Q2 DEMO EXISTING EXHAUST DUCT SHOWN 18 19 20 21 I G { { E i t 1 y i S t 1 7 1 I t t i 110" L7 EAi' [10 , # Ey i - 1 [ # t t [ t tII C(1 Eli, 7 8 ( — D { tF B iF $- }— { t ! t r { # jj (/its 1 t # i e a 1 t 1 t - } ! 7 ! ; � I � i t - f }!""r'� t""YYtl ! f 7 1 t�tJ! 7 t ! t r� { {C � I�� �� FEC { ]jjj IC { -1 1,2 Cz f` C'Z C'T ♦ .I ♦� �4'♦� J J J J J J J 4, J j Fk J J - J J J J /' ell / ' ' J J ♦�I#S�SI AIB J J e ♦ e J J J e J � aee / ♦' J / / O J /' J ♦♦ /J''f ♦' /'!/' /' /♦ J'/J -JJ / ♦ ♦ /♦ ♦ / / / / / ♦J ♦ / ♦ / 0,♦ ♦ / J J J J ' J �J / J J J J J J J'J i i d ♦ e" ♦ ♦ ♦ / ♦ / .1♦'� / / / ,- ♦ / ♦ / ' J J J J J J J J ' ' ' ' ' ' ' J ♦I / ♦ ♦ ♦ / { —' r,>_=�T--r-T-s-T-r-r-s-7--s-�^-7--+^-T-"�^'-7---7-Y-�- J"�'�- r -T 1-7- l -T l T -T -T7 -T T-�T-T-T-T-T-r-T-T-7-T-T-T�7-T-7- 1-7- 1-7-T-7- 1-7- 1 -7 -7 -T7 -'T / ♦ ♦ ♦ ♦ I I ♦ / ♦ I ♦ / / I / ♦ / ♦ / i i : ♦ ♦ ♦ ♦ ♦ ♦ ♦ ♦ ♦ ♦ , ♦ ♦ ♦ ♦ / / / ♦ / ♦ ♦ ♦ ♦ ♦ ♦ ♦ / ♦ ♦ ♦ ♦ ♦ / ♦ / ♦ ♦ I ♦ ♦ ♦ ♦ ♦ ♦ ♦ ♦ / / / ♦ ♦ / ♦ ♦ ♦ ♦ / ♦ ♦ ♦ ♦ ♦ ♦ ♦ ♦ ♦ / ♦ ♦ / ♦ ♦ ♦ ♦ ♦ ♦ ♦ ♦ ♦ ♦ / / /J='7' �7J - /L-; - ,- , ;• i• J=`"' i yt� r :rte'-,"`—/�'' ;.'�—_....�.:_. �.._.__..-,.:.—,��.� -- ,'2,i `,`,i , , , , .`a fit J J J J J '-e J J J ; t J 1 I /E♦./ 'l' J J/6 J ' J ' J ' J%/� tl'�-°�'� �' J..���' ♦ �/ 'tJ ♦' r' �J ' J♦ Vis- �J J ,[{' (yp % J J J J J:,rt� -.ry�, J ,1��+ri�J ♦� !�'Jj j([♦J J' ♦/J♦/i y , J, �/— �O- �d-r J �Jt . iyJ J ' ' J ' i i J ' ' J ' J I # lU 1 � OF IJEY1! L� _�f 'i�4 ! f ! ! ! e J i' I ! /1 �.-,.Il�.s ./s 1 , # ♦ �tzr' J J t ♦i J J J J J J 1 ♦' n' I J J A J L/ ...r'i "i .t'i J i r' i� i i /i .� , ♦ ! ! ! ! ! /. " ! d i E /1 ! -♦' i CLOSE[ 108 { CPT �I FJ LEVEL 1 MECHANICAL DEMO PLAN SCALE: 1/4'= 1'-0' I CPT TO LATCHjj CPT t� I { REVIEW D FOR CODE COMPLIANCE APPROVED s; OCT 12 2016 BUILD .`'=" D1V4I# I— W 1— C tY W i C� Z `= 00 o .iILLM 4C o 00 0 x zrn o LL Uj C O vien cr �i Q N O p LL! \ LU Q W !— o = LU tW c n a - O O (0 O N 0) M N f'7 M co co O O N N w [ '� N V C z O x CO) � _ N 00rnrn LLJ V+ z 4' m W O O U Za � Lu = p m I At E � /1 U J E 1, J LU J —G)I- E I RECEIVED CITY OF TUKWILA OCT 04 2016 PERMIT CENTER Legal: THIS DRAWING AND THE DESIGN HEREIN ARE THE PROPERTY OF UNIVERSITY MECHANICAL CONTRACTORS, INC. FOR THEIR USE IN CONSTRUCTION OF THIS PROJECT. NO- OTHER USE SHALL BE PERMITTED WITHOUT THE WRITTEN CONSENT OF UNIVERSITY MECHANICAL CONTRACTORS, INC. V. A wASy�O�� c� v �'��ONA�- '- 09/26/2m16 Drawn By KH Checked By RK Original Issue Date 08/24/16 Job No. 6880 Scale AS SHOWN Sheet No. MD2.01 17 I I I I I I { I — A — UP CORRIDOR 109 — A Q DEMO ALL CEILING HVAC SYSTEMS THAT SERVE THE SPACE SHOWN FIELD VERIFY ROUTING Q2 DEMO EXISTING EXHAUST DUCT SHOWN 18 19 20 21 I G { { E i t 1 y i S t 1 7 1 I t t i 110" L7 EAi' [10 , # Ey i - 1 [ # t t [ t tII C(1 Eli, 7 8 ( — D { tF B iF $- }— { t ! t r { # jj (/its 1 t # i e a 1 t 1 t - } ! 7 ! ; � I � i t - f }!""r'� t""YYtl ! f 7 1 t�tJ! 7 t ! t r� { {C � I�� �� FEC { ]jjj IC { -1 1,2 Cz f` C'Z C'T ♦ .I ♦� �4'♦� J J J J J J J 4, J j Fk J J - J J J J /' ell / ' ' J J ♦�I#S�SI AIB J J e ♦ e J J J e J � aee / ♦' J / / O J /' J ♦♦ /J''f ♦' /'!/' /' /♦ J'/J -JJ / ♦ ♦ /♦ ♦ / / / / / ♦J ♦ / ♦ / 0,♦ ♦ / J J J J ' J �J / J J J J J J J'J i i d ♦ e" ♦ ♦ ♦ / ♦ / .1♦'� / / / ,- ♦ / ♦ / ' J J J J J J J J ' ' ' ' ' ' ' J ♦I / ♦ ♦ ♦ / { —' r,>_=�T--r-T-s-T-r-r-s-7--s-�^-7--+^-T-"�^'-7---7-Y-�- J"�'�- r -T 1-7- l -T l T -T -T7 -T T-�T-T-T-T-T-r-T-T-7-T-T-T�7-T-7- 1-7- 1-7-T-7- 1-7- 1 -7 -7 -T7 -'T / ♦ ♦ ♦ ♦ I I ♦ / ♦ I ♦ / / I / ♦ / ♦ / i i : ♦ ♦ ♦ ♦ ♦ ♦ ♦ ♦ ♦ ♦ , ♦ ♦ ♦ ♦ / / / ♦ / ♦ ♦ ♦ ♦ ♦ ♦ ♦ / ♦ ♦ ♦ ♦ ♦ / ♦ / ♦ ♦ I ♦ ♦ ♦ ♦ ♦ ♦ ♦ ♦ / / / ♦ ♦ / ♦ ♦ ♦ ♦ / ♦ ♦ ♦ ♦ ♦ ♦ ♦ ♦ ♦ / ♦ ♦ / ♦ ♦ ♦ ♦ ♦ ♦ ♦ ♦ ♦ ♦ / / /J='7' �7J - /L-; - ,- , ;• i• J=`"' i yt� r :rte'-,"`—/�'' ;.'�—_....�.:_. �.._.__..-,.:.—,��.� -- ,'2,i `,`,i , , , , .`a fit J J J J J '-e J J J ; t J 1 I /E♦./ 'l' J J/6 J ' J ' J ' J%/� tl'�-°�'� �' J..���' ♦ �/ 'tJ ♦' r' �J ' J♦ Vis- �J J ,[{' (yp % J J J J J:,rt� -.ry�, J ,1��+ri�J ♦� !�'Jj j([♦J J' ♦/J♦/i y , J, �/— �O- �d-r J �Jt . iyJ J ' ' J ' i i J ' ' J ' J I # lU 1 � OF IJEY1! L� _�f 'i�4 ! f ! ! ! e J i' I ! /1 �.-,.Il�.s ./s 1 , # ♦ �tzr' J J t ♦i J J J J J J 1 ♦' n' I J J A J L/ ...r'i "i .t'i J i r' i� i i /i .� , ♦ ! ! ! ! ! /. " ! d i E /1 ! -♦' i CLOSE[ 108 { CPT �I FJ LEVEL 1 MECHANICAL DEMO PLAN SCALE: 1/4'= 1'-0' I CPT TO LATCHjj CPT t� I { REVIEW D FOR CODE COMPLIANCE APPROVED s; OCT 12 2016 BUILD .`'=" D1V4I# I— W 1— C tY W i C� Z `= 00 o .iILLM 4C o 00 0 x zrn o LL Uj C O vien cr �i Q N O p LL! \ LU Q W !— o = LU tW c n a - O O (0 O N 0) M N f'7 M co co O O N N w [ '� N V C z O x CO) � _ N 00rnrn LLJ V+ z 4' m W O O U Za � Lu = p m I At E � /1 U J E 1, J LU J —G)I- E I RECEIVED CITY OF TUKWILA OCT 04 2016 PERMIT CENTER Legal: THIS DRAWING AND THE DESIGN HEREIN ARE THE PROPERTY OF UNIVERSITY MECHANICAL CONTRACTORS, INC. FOR THEIR USE IN CONSTRUCTION OF THIS PROJECT. NO- OTHER USE SHALL BE PERMITTED WITHOUT THE WRITTEN CONSENT OF UNIVERSITY MECHANICAL CONTRACTORS, INC. V. A wASy�O�� c� v �'��ONA�- '- 09/26/2m16 Drawn By KH Checked By RK Original Issue Date 08/24/16 Job No. 6880 Scale AS SHOWN Sheet No. MD2.01 Eel 1 LEVEL 2 MECHANICAL DEMO PLAN SCALE: 1/4' = 1'-0' REVIEWED FOR CODE COMPLIANCE APPROVED OCT 12 2016 I` I City of Tukwila BUILDING DIVISION., O i RECEIVED CITY OF TUKWILA OCT 042016 PERMIT CENTER Legal: THIS DRAWING AND THE DESIGN HEREIN ARE THE PROPERTY OF UNIVERSITY MECHANICAL CONTRACTORS, INC. FOR THEIR USE IN CONSTRUCTION OF THIS PROJECT. NO OTHER USE SHALL BE PERMITTED WITHOUT THE WRITTEN CONSENT OF UNIVERSITY MECHANICAL CONTRACTORS, INC. O �) O N � � N 1 C, O (3 v) N W G CC W C_ iv zi aaaaaaa O ¢ ' Z W �� o. va J LL. T 00 LL o W O ¢ �S ui � 0 WUj � ~ Q 0 _ LU O 0 iii 3 d a- O O (D O N a) 0) N to to M r7 O O C14 Z O X CL L? < {i `AW _r Lr) O Jr- N �� U Q7 � C Q Uv1 J Cr.� � 4 v_c_ U) t. � uiLIJ E O U E J LLJ 3 WNEW N �O of WASy,� A 5 d0 �0� FFG/ST ERF'O �SS�D NAI- EAG @9/26/2016 Drawn By KH Checked By RK Original Issue Date 08/24/16 Job No. 6880 Scale AS SHOWN Sheet No. MD2,02 w c a cJ f. cc Li V. -s- C Q; L CD O G° i as C w 'Kf Ln Vi LJ co 0 C5 LL f33 16 17 18 19 20 21 I � I I ► ( 8 i e - i I f I � I • I I I tI I I I I I l I l I I CV 1 a E a I I N 18X1 0 _ s EXHA U 1W9 U I—' W N L U i G W I FEF - L O r Vi � 0 z 00 O O E i I 18) !` L U Z O Q - M O (R Q a)W L w c 0 Uj Q F Q W 0 L O az I � I I 0000 i � I I 0 0 0 C) .v LEVEL 1 MECHANICAL PLAN 1 SCALE: 1/4' = 1'-0' a o N. C3 `� L � DRAWING NOTES: 01 CONNECT NEW EXHAUST DUCTWORK TO EXISTING EXHAUST LOUVER PLENUM 02 24X24 MAKEUP AIR LOUVER THROUGH RESTROOM DOOR PROVIDED BY OTHERS 3� MAKEUP AIR LOUVER MOUNTED IN WALL ABOVE DOOR BELOW CEILING AND DUCT ROUTED INTO SPACE AND DOWN TO CEILING GRILL IN RESTROOM SPACE REVIEWED FOR CODE COMPLIANCE APPROVED r OCT 12 2016 I City d TukWtla BUILDING DIVISION PERMIT CENTER Legal: THIS DRAWING AND THE DESIGN HEREIN ARE THE PROPERTY OF UNIVERSITY MECHANICAL CONTRACTORS, INC. FOR THEIR USE IN CONSTRUCTION OF THIS PROJECT. NO OTHER USE SHALL BE PERMITTED WITHOUT THE WRITTEN CONSENT OF UNIVERSITY MECHANICAL CONTRACTORS, INC. 1 o N I N 0 U U U I—' W N L W L O r Vi � 0 z 00 O O !` L U Z Q - M O (R Q a)W w 0 Uj Q F Q W 0 L a_ d O (O O N O) r- � N CSO Cfl M M Coco O O C14 ■ c O j< tel° C Lr) 0 N _ (� V C O / � /CO) �� Zv c . C Uj > V LL J L .o U !� U w 3 W J N OPS V � �O of Was e co v Q 5 40 /O NA t EAG 09/2612016 Drawn By KH Checked By RK Original Issue Date 08/24/16 Job No. 6880 Scale AS SHOWN Sheet No. M2.01 I Q e- U) CONTROLS SEQUENCE: O AIR HANDLING UNIT RESTROOM EXHAUST SEQUENCE OF OPERATION A. OPERATION A. OPERATION 1 THE INDOOR FAN COIL UNIT SHALL BE FURNISHED WITH A COMPLETE, FACTORY- 1 THE FAN PROVIDES EXHAUST FOR THE NEW SPACE RESTROOMS TO CONTROL THE SPREAD OF ODORS. INSTALLED, DDC CONTROL SYSTEM BASED ON AN OPEN PROTOCOL MATCHING BUILDING'S EXISTING PROTOCOL 2 THE FAN IS INTENDED TO OPERATE WHILE BUILDING IS OCCUPIED 2 THE UNIT IS TO BE FURNISHED COMPLETE WITH COOLING COIL, HEATING COIL, OSA MIXING BOX_ B. OCCUPIED MODE W/ ASSOCIATED DAMPER ACTUATORS, VARIABLE VOLUME SUPPLY FAN WITH VFD, AND FILTERS. 1 FAN START/STOP: ON COMMAND FROM THE BMS, SYSTEM STARTUP SEQUENCE SHALL BE INITIATED. THE FAN SHALL START 3 MICROPROCESSOR -BASED CONTROLS SHALL BE PROGRAMMED AT THE MANUFACTURER'S FACTORY. 2 THE EXHAUST FAN SHALL BE BALANCED TO MATCH OSA DAMPERS AND PROVIDE A NUTRAL SYSTEM PRESSURIZATION. INCLUDE PROGRAMS FOR VARIABLE VOLUME OPERATION FOR SUPPLY FANS C. UNOCCUPIED MODE VIA VARIABLE SPEED DRIVES, DRY BULB ECONOMIZER OPERATION, BUILDING PRESSURE CONTROL, 1 THE RESTROOM EXHAUST FAN IS INTENDED TO OPERATE WHILE BUILDING IS OCCUPIED. IF AHU IS RUNNING THIS EXHAUST FAN SHALL RUN DEMAND CONTROL VENTILATION, AND DISCHARGE AIR RESET BASED ON OUTDOOR AIR TEMPERATURE, D. ARE ALARM OCCUPIED/UNOCCUPIED CONTROL WITH MORNING WARM-UP OPTIMAL START SEQUENCE. 1 ON RECEIPT OF AFIRE ALARM SIGNAL THE EXHAUST FAN SHALL. STOP B. OCCUPIED MODE 1 UPON INITIATION OF THE OCCUPIED CYCLE AS DETERMINED BY THE BUILDING AUTOMATION SYSTEM, THE MANUFACTURER'S MICROPROCESSOR CONTROL SYSTEM SHALL ENABLE THE OCCUPIED CONTROL SEQUENCE. 2 WARMUP: MORNING WARMUP START SHALL BE CALCULATED BY THE MANUFACTURER'S OPTIMAL START Q PROGRAM. THE INTERNAL CONTROLS SHALL START THE SUPPLY FAN WITH ALL DAMPERS IN THE RECIRCULATION MODE. MORNING WARMUP SHALL CONTINUE UNTIL RETURN AIR TEMPERATURE REACHES HEATING SETPOINT. PLEASE NOTE THERE IS NO HEAT IN THE UNIT. 3 OCCUPIED MODE: ON COMPLETION OF THE WARMUP CYCLE, THE VENTILATION DAMPER SHALL OPEN TO U) MINIMUM POSITION. WHEN EQUIPPED WITH AN OSA MEASUREMENT STATION, THE OUTSIDE AIR DAMPER SHALL MODULATE TO MAINTAIN VENTILATION AIR SETPOINT. ECONOMIZER 0 MODULE CONTROLS SHALL SEQUENCE TO MAINTAIN DISCHARGE AIR SETPOINT. 4 SUPPLY FAN CONTROL: SUPPLY AIRFLOW SHALL BE CONTROLLED BY A DUCT STATIC PRESSURE SENSOR LU ¢ WHICH SHALL MODULATE THE SUPPLY FAN VARIABLE FREQUENCY DRIVE TO MAINTAIN SETPOINT. 7 ARE ALARM SIGNAL ON RECEIPT OF AFIRE ALARM FROM THE DIVISION 16 CONTRACTOR'S SYSTEM, THE V,r W BUILDING AUTOMATION SYSTEM SHALL STOP THE AIR HANDLING UNIT. C. UNOCCUPIED MODE 1 IN UNOCCUPIED MODE, AS ESTABLISHED BY THE BUILDING AUTOMATION SYSTEM OR MANUFACTURER'S INTEGRAL CONTROL PANEL, THE AIR HANDLING UNIT SHALL BE OFF WITH DAMPERS IN 100% RETURN AIR a POSITION. o — m — — B _ _ _ 3 __ ____ I 22x16 MPS — h — — A _ _— A _ —__ — , DRAWING NOTES: 01 OSA EXTERIOR LOUVER, LOUVER SIZE AND LOCATION TO BE COORDINATE WITH GC BASED ON EXTERIOR TILING. LOUVER SHALL HAVE GREATER THAN 50% FREE AREA AND INLET SHALL BE PROTECTED AGAINST LOCAL WEATHER CONDITIONS. 1 LEVEL 2 MECHANICAL PLAN SCALE: 1/4' = 1'-0' REVIEWED FOR CODE COMPLIANCE j = APPROVED A ..j. OCT 12 2016 City of Tukwila BUILDING DIVISION RECEIVED I CITY OF TUKWILA OCT 0 4 2016 PERMIT CENTER Legal:. THIS DRAWING AND THE DESIGN HEREIN ARE THE PROPERTY OF UNIVERSITY MECHANICAL CONTRACTORS, INC. FOR THEIR USE IN CONSTRUCTION OF THIS PROJECT. NO OTHER USE SHALL BE PERMITTED WITHOUT THE WRITTEN CONSENT OF UNIVERSITY MECHANICAL CONTRACTORS, INC. I -- w tn I— >j CL E1 ziaaaaaaa V. 9PoF WAS �O !�`�. 't GIST EF SS�O NA 1. Drawn By KH Checked By RK Original Issue Date 08/24/1.6 Job No. 6880 Scale AS SHOWN Sheet No. M2.02 O v/ Z ♦Vw/ 0 Z Q CD 0 4C T CO 0 0) Q c U) M LLj 3 0 W0 H LU ¢ 4- V,r W Q Q o 0 °- a o C) co O N 0)� of N I I �t c0 co r7 r� 0 C4 C4� z O 0 = X IL U .. J N 00+ J V 0 f2 a) v c J z d9r Im 4C '�-C— LU = H 0') U >oz � o z LU =' m V cp U LU E 0 CN LU 3 1.0 J N V. 9PoF WAS �O !�`�. 't GIST EF SS�O NA 1. Drawn By KH Checked By RK Original Issue Date 08/24/1.6 Job No. 6880 Scale AS SHOWN Sheet No. M2.02 � I ! ! o co Do W ! I LA � co up N O1 FIELD FABRICATE UNIT HANGING SYSTEM BASED ON STRUCTURAL CALCULATIONS AND SEISMIC REQUIREMENTS, REF STRUCTURAL SEE DRAWING M1.02 22 LEVEL 2 MECHANICAL PIPING PLAN 1 SCALE: 1/4' = 1'-0' 101 OWN � RECEIVED CITY OF TUKWILA N OCT 0 4 2016 PERMIT CENTER REVIEWED FOR CODE COMPLIANCE APPROVED Legal: THIS DRAWING AND THE DESIGN OCT 12 2016 UN VEIRSITY MECHANICALARE THE OF CONTRACTORS, INC. FOR THEIR City Of Tukwila BUILDING DIVISION USE IN CONSTRUCTION OF THIS PROJECT. NO OTHER USE SHALL BE PERMITTED WITHOUT THE WRITTEN CONSENT OF UNIVERSITY MECHANICAL CONTRACTORS, INC. � of N o � N ONO U co N N I—' W t!1 L W z co z �o 0 j r 0i 5= L. LL W Q O 0 S c 0 � Cf) Q �W oUj LU Q � = d' W o n W ( 2 �� c o o co C) N C r- 0') N � cp CDMCD 0 0 CN. ■ N C Z/ V ■■,� O X Q i c>_ ■` V J � >- �C © � N � °° CL --C■� °'� < Z � LIJ 0.E - U = � o Z Z W m e .Q! /O� cp LL1 L E O V N E Lu LLI 3 a� i= PL V �O °E wAsy�O�� Q c0 v ,p 5 40' FFG/ST6RF"O \��v S/O NA %-ENG 09/26/2016 Drawn By KH Checked By RK Original Issue Date 08/24/16 Job No. 6880 Scale AS SHOWN Sheet No. MP2.02 ■ DUCT LINE EOUIVALENTS LEGEND SINGLE LINE DOUBLE LINE DESCRIPTION 9O' ELBOW UP (SUPPLY) 2 90' ELBOW UP (RETURN/EXHAUST) Q--� 90' ELBOW DOWN (SUPPLY) 90' ELBOW DOWN (RETURN/EXHAUST) �-I--� � RADIUS ELBOW UP (SUPPLY) Z4 ----e �� RADIUS ELBOW UP (RETURN/EXHAUST) X�-I--2 RADIUS ELBOW DOWN (SUPPLY) � RADIUS ELBOW DOWN (RETURN/EXHAUST) ROUND DUCT UP (S/R/E) �? ( ROUND DUCT DOWN (S/R/E) TURNING VANE ELBOW fe RADIUS ELBOW, RECT RADIUS ELBOW, ROUND TRANSITION (ROUND ORECTANGU A R ) �-®--2 TRANSITION (RECTANGULAR TO ROUND) RECT � SPIN -IN TAKEOFF -�-- ROUND -� ROUND CONICAL TEE �- ROUND -� TEE WITH TURNING VANES BRANCH TAKEOFF, RECT RECT BRANCH TAKEOFF, ROUND �- ROUND -� RECT BRANCH TEE, RECT RECT CONICAL SPIN -IN TAKEOFF �- ROUND .. ROUND BOOT TEE -E- ROUND4�v -�- 45 LATERAL 45' CONICAL LATERAL A71OCHANGE RRIISEEV (R)NOR DROP (D) I --Z AIR FLOW DIRECTION - SUPPLY -�--H-V -+-� AIR FLOW DIRECTION - RETURN OR EXHAUST ---I]] DUCT END CAP I Vz/46 ����IIIIIIII FLEXIBLE DUCTWORK tMANUAL VOLUME DAMPER R z- 1-� REMOTE VOLUME DAMPER FM FIRE/SMOKE APER -PROVIDE ACCESS FD FIRE DAMPER -PROVIDE ACCESS woo ❑ MOTOR OPERATED DAMPER BDD I eoo BACKDRAFT DAMPER HUMIDIFIER �♦ WALL MOUNTED TSTAT WiTH CONTROL LINE SUPPLY DIFFUSER ® SUPPLY GRILLE RETURN/EXHAUST GRILLE FE_F-_X_1 EQUIPMENT MARK 0 DIFFUSER/GRILLE DESIGNATION 0 ROUND DUCT T=. B=. TOP OF DUCT, BOTTOM OF DUCT Lo r I GENERAL SYMBOL ABBR DESCRIPTION 45 45 DOWN 90 AD ACCESS DOOR IN CEILING AD ACCESS DOOR IN WALL ALIGNMENT GUIDE _ ANCHOR AUTOMATIC CONTOL VALVE (3 -WAY) - AUTOMATIC CONTROL VALVE (2 -WAY) -� BALANCING VALVE �I- BV BALL VALVE oP XX' -XX" BOP BOTTOM OF PIPE ELEVATION BREAK BFV BUTTERFLY VALVE E CAP CENTERLINE xX'-XX" CL -EL CENTERLINE OF PIPE ELEVATION -- CHK CHECK VALVE CIRCUIT SETTER X DETAIL TAG X -X G DN DOWN X ELEVATION TAG i`',r, i 2 P" VA IT l#� )Ui,=D FOR: 0 & echanical Electrical [11'Plumbing Q43 a's Piping C i of Tukwilat St. R.DINO DIVISION PIPING SYMBOL ABBR FLOW ARROW _�- AAV GAS COCK - BFW- BFW GLOBE VALVE _ GV GATE VALVE IE xx'-xx" IE INVERT PIPE ELEVATION PITCH ,, PM W CHR PITCH LEFT PITCH CHS PITCH RIGHT -CR- CR PLUG -CS- POC POINT OF CONNECTION COOLING COIL PG PRESSURE GAUGE _ PRV PRESSURE REDUCING VALVE CEILING CNTFGL ROLLING 45 DOWN - FOR- FOR REDUCER - FOS- FOS REDUCING CONCENTRIC -� FOV REDUCING ECCENTRIC -G RV RELIEF VALVE - GLR- GLR SHEET NOTE DESIGNATION - GLS- GLS SLEEVE - SV SOLENOID VALVE }_ HG TEE DOWN -I- HPS TEE �L- TH THERMOMETER XxxxxxxxX HWS LONG TAG 9 CHARCTERS MAX xxxxxx LCR MEDIUM TAG 6 CHARCTERS MAX FX-X-X-xl LPS SHORT TAG 4 CHARCTERS MAX oP XX' -XX' TOP TOP OF PIPE ELEVATION ---NIH- U UNION _R_ o UP ® MG VERTICAL SLEEVE - MPS- MPS VALVE IN PIPE RISE OR DROP - STIR WYE TYPE STRAINER i`',r, i 2 P" VA IT l#� )Ui,=D FOR: 0 & echanical Electrical [11'Plumbing Q43 a's Piping C i of Tukwilat St. R.DINO DIVISION PIPING SYMBOL ABBR DESCRIPTION ` AAV AUTOMATIC AIR VENT - BFW- BFW BOILER FEED WATER -p- AMS BUCKET TRAP -CA- CA CONTROL AIR - CHR- CHR CHILLED WATER RETURN - CHS- CHS CHILLED WATER SUPPLY -CR- CR CONDENSER WATER RETURN -CS- CS CONDENSER WATER SUPPLY COOLING COIL CFM FLANGE CHLR CHILLER FLEX CEILING CNTFGL FLOAT AND THERMOSTATIC - FOR- FOR FUEL OIL RETURN - FOS- FOS FUEL OIL SUPPLY - FOV- FOV FUEL OIL VENT -G G NATURAL GAS - GLR- GLR GLYCOL RETURN - GLS- GLS GLYCOL SUPPLY - HCR- HCR HIGH PRESSURE CONDENSATE RETURN -HG- HG HOT GAS -HPS- HPS HIGH PRESSURE STEAM - HWR- HWR HEATING HOT WATER RETURN - HWS- HWS HEATING HOT WATER SUPPLY - LCR- LCR LOW PRESSURE CONDENSATE RETURN - LPS- LPS LOW PRESSURE STEAM 0 MAV MANUAL AIR VENT - MCR- MCR MEDIUM PRESSURE CONDENSATE RETURN _R_ o METER -MG- MG MEDIUM PRESSURE NATURAL GAS - MPS- MPS MEDIUM PRESSURE STEAM - PCR- PCR PUMPED CONDENSATE RETURN 0 PI PRESSURE INDICATOR -RL- RL REFER LIQUID -RS- RS REFER SUCTION T C X C- 0- L� TEMPERATURE PRESSURE TEST PLUG Q TI TEMPERATURE INDICATOR TS TS TEMPERATURE SENSOR VB VACUUM BREAKER VENTURI M 0 00 AC AIR CONDITIONING UNIT AF AIRFOIL AFF ABOVE FINISHED FLOOR AHU AIR HANDLING UNIT AMB AMBIENT AMS AIRFLOW MEAQJRING UNIT B BOILER BDD BACKDRAFT DAMPER BHP BRAKE HORSE'OWER BI BACKWARD INCLINED BOD BOTTOM OF DJCT BOT BOTTOM BTUH BRITISH THERMAL UNIT PER HOUR CC COOLING COIL CFM CUBIC FEET PER MINUTE CHLR CHILLER CLG CEILING CNTFGL CENTRIFUGAL COMB COMBUSTION COND CONDENSER / CONDENSATE CONT CONTINUE / CONTROL CONTR CONTRACTOR CP CIRCULATING PUMP CRAC COMPUTER ROOM AIR CONDITIONING UNIT CT COOLING TOWER CU CONDENSING UNIT / CUBIC Cv FLOW COEFFICIENT CV CONSTANT VOLUME CWP CHILLED WATER PUMP D DRAIN DB DRY BULB / )ECIBEL DEG DEGREE DIA DIAMETER DIM DIMENSION DISCH DISCHARGE DMPR DAMPER DN DOWN ... l • •, as EA EXHAUST AIR EAT ENTERING AIR TEMPERATURE ECONO ECONOMIZER EDH ELECTRIC DUCT HEATER EER ENERGY EFFICIENCY RATIO EF EXHAUST FAN EFF EFFICIENCY ELEC ELECTRIC ELEV ELEVATION EQUIV EQUIVALENT ESP EXTERNAL STATIC PRESSURE EVAP EVAPORATOR / EVAPORATIVE EWT ENTERING WATER TEMPERATURE EXH EXHAUST EXT EXTERIOR / EXTERNAL F FAHRENHEIT FC FORWARD CURVE FCU FAN COIL UNIT FD FIRE DAMPER / FLOOR DRAIN FLR FLOOR FLTR FILTER FOIC FURNISHED BY OWNER INSTALLED BY CONTRACTOR FPM FEET PER MINUTE FSD FIRE SMOKE DAMPER FT FEET FTU FAN TERMINAL UNIT FV FACE VELOCITY GA REVISiONS GAL rade to the SCOPO of ~ ,;` ,r approval of GPM Division. NOTE F 2 c a ns,� plan submittal and m--,% : ,_ :zonal pian review fees. 1 ... l • •, as EA EXHAUST AIR EAT ENTERING AIR TEMPERATURE ECONO ECONOMIZER EDH ELECTRIC DUCT HEATER EER ENERGY EFFICIENCY RATIO EF EXHAUST FAN EFF EFFICIENCY ELEC ELECTRIC ELEV ELEVATION EQUIV EQUIVALENT ESP EXTERNAL STATIC PRESSURE EVAP EVAPORATOR / EVAPORATIVE EWT ENTERING WATER TEMPERATURE EXH EXHAUST EXT EXTERIOR / EXTERNAL F FAHRENHEIT FC FORWARD CURVE FCU FAN COIL UNIT FD FIRE DAMPER / FLOOR DRAIN FLR FLOOR FLTR FILTER FOIC FURNISHED BY OWNER INSTALLED BY CONTRACTOR FPM FEET PER MINUTE FSD FIRE SMOKE DAMPER FT FEET FTU FAN TERMINAL UNIT FV FACE VELOCITY GA GAUGE GAL GALLONS GALV GALVANIZED GPM GALLONS PER MINUTE GWB GYPSUM WALLBOARD H HUMIDIFIER HC HEATING COIL HD HEAD HORIZ HORIZONTAL HP HORSEPOWER HT HEAT TRACE HVAC HEATING, VENTILATING, AND AIR CONDITIONING HVACDCS HVAC DUCT CONSTRUCTION STANDARDS, METAL AND FLEXIBLE (SMACNA) HX HEAT EXCHANGER ID INDIRECT DRAIN / INSIDE DIAMETER IN INCH KW KILOWATT L LONG / LENGTH LAT LEAVING AIR TEMPERATURE LB POUND LWT LEAVING WATER TEMPERATURE MBH THOUSAND BTU PER HOUR MECH MECHANICAL MOD MOTOR OPERATED DAMPER MTD MOUNTED MVD MANUAL VOLUME DAMPER NC NORMALLY CLOSED / NOISE CRITERIA NIC NOT IN CONTRACT NO NORMALLY OPEN / NUMBER NTS NOT TO SCALE OBD OPPOSED BLADE DAMPER OC ON CENTER OD OUTSIDE DIMENSION OR DIAMETER OSA OUTSIDE AIR P PUMP PBD PARALLEL BLADE DAMPER PD PRESSURE DROP / PUMPED DRAIN PL PLENUM POC POINT OF CONNECTION PT POST -TENSION SLAB QD QUICK DISCONNECT RA RETURN AIR REF REFERENCE REV REVISION RF RELIEF FAN RH RELATIVE HUMIDITY RIO ROUGH -IN ONLY RPM REVOLUTIONS PER MINUTE SA SUPPLY AIR SCFM STANDARD CUBIC FEET PER MINUTE SCH SCHEDULE SECT SECTION SENS SENSIBLE SF SUPPLY FAN / SQUARE FOOT SL SOUND LINE (INSIDE DUCT INSULATION ) SMACNA SHEET METAL AND AIR CONDITIONING CONTRACTORS NATIONAL ASSOCIATION SP STATIC PRESSURE SQ SQUARE SS STAINLESS STEEL ST SOUND TRAP TBV TOWER BYPASS VALVE TCV TEMPERATURE CONTROL VALVE TDH TOTAL DYNAMIC HEAD TOD TOP OF DUCT TOS TOP OF STEEL TP TOTAL PRESSURE TRNSN TRANSITION TSP TOTAL STATIC PRESSURE TYP TYPICAL UBD UPBLAST DISCHARGE UH UNIT HEATER UNO UNLESS NOTED OTHERWISE VA VALVE VAV VARIABLE AIR VOLUME VD VOLUME DAMPER VENT VENTILATION / VENTILATOR VEL VELOCITY VFO VARIABLE FREQUENCY CONTROLLER A VIBRATION ISOLATOR VIV VARIABLE INLET VANES W INSULATED DUCT / WATT / WIDE WB WET BULB (TEMPERATURE) WG WATER GAUGE WT WEIGHT M2.01 LEVEL 1 MECHANICAL PLAN Permit No, t�_l &-- 0 ( Is - Plan ravieln approval is subject to errors and omissions. Approval of consiruciion docurnents does not authoii1.e the violation of any adopters code or ordinance. Reco ipt of approved Field Copy and condi ' ns s acknovdedv,d: ey: - d 5 �X, XK Date: to Z/ City of Tukwila all III nlnirl nit/101AXII GENERAL NOTES 1. THE MECHANICAL SYSTEM SHALL CONSIST OF ALL WORK SHOWN ON DRAWINGS. DIAGRAMS, AND AS DESCRIBEDIN THE SPECIFICATIONS. 2 INSTALL MECHANICAL WORK AS HIGH AS POSSIBLE, TiGHT TO STRUCTURE ABOVE 3. THE MECHANICAL DRAWINGS ARE SCHEMATIC IN NATURE AND DO NOT ATTEMPT TO SHOW ALL REQUIRED RETAILS. OFFSETS. REFER TO ARCHITECTURAL AND STRUCTURAL DRAWINGS FOR CONSTRUCTION 4. ITEMS NOTED AS 'TYPICAL' OR 'TVP' ON ANY DRAWING APPLY TO THAT PARTICULAR DRAWING. 5. COORDINATE WiTH SPECIFICATIONS. IN CASE OF CONFLICT BETWEEN SPECIFICATIONS AND DRAWINGS THE MORE STRINGENT SHALL APPLY. 6. PROVIDE NEC CODE MINIMUM HORIZONTAL AND VERTICAL WORKING CLEARANCES FOR ALL ELECTRICAL. PANELS AND EQUIPMENT. OFFSET MECHANICAL WORK AS REQUIRED. 7. COORDINATE ALL M8>IAN CA. WORK WITH OTHER TRADES TO INSURE PROPER AND ADEQUATE INTERFACE OF THEIR WORK WiTH THE WORK OF THIS CONTRACTOR PROVIDE COORDINATED SHOP DRAWINGS PFJDR TO FABRICATION AND INSTALLATION. 8. MECHANICAL EQUIPMENT SHALL NOT BE USED FOR TEMPORARY HEAT DURING CONSTRUCTION. 9. VERIFY EXISTING CONDITIONS BEFORE COMMENCING ANY WORK ON AN DUSTING MECHANICAL SYSTEM. 10. ALL DUCTWORK SIZES SHOWN ARE INSIDE CLEAR. ADD APPROPRIATE DUMION FOR INSULATION OR DUCT LINER TO OBTAIN `TOTAL' DUCT SIZE 11. Ii+LSTALL COMBINATION RWSMOKE DAMPERS AT ALL LOCATIONS WHERE DUCTS PENETRATE FIRE RATED WALLS. DAMPER FIE RATING SHALL BE 1-1/2 HOUR UNLESS NOTED OTHERWISE COORDINATE DAMPER ACCESS WiTH GENERAL CONTRACTOR AND ELECTRICAL CONNECTIONS WITH ELECTRK:A. CONTRACTOR. 12 REFER TO ARCHITECTURAL REFLECTED CEILING PLANS AND ELEVATIONS FOR EXACT LOICATiON RE ALL DIFFUSERS AND GRILLES. PROVIDE SEPARATE COLING DIFFUSER SHOP DRAWINGS FOR APPROVAL 13. MAXIMUM FLEX DUCT LENGTH SHALL BE 6'-0' WiTH 0.5 x DUCT DIAMETER OFFSET, UNLESS NOW OTHERWISE. 14. PROVIDE REMOTE ACTUATED DAMPERS FOR ALL VOLUME DAMPERS OVER INACCESSIBLE CEILINGS AND SOFFITS. REFER TO ARCHITECTURAL DRAWINGS FOR CEILING TYPES. 15. PROVIDE TRANSITIONS AS REQUIRED TO CONNECT DUCTWORK TO AIR TERMINAL. UMTS. FANS, ANO OTHER MECHANICAL EQUIPMENT. 16. PROVIDE DIFFUSER AND GRILLE FRAMES COMPATIBLE WiTH ARCHITECTURAL COLING TYPE REFER TO ARCHITECTURAL REFLECTED COLING PLANS FOR CEE ING TYPE 17. COORDINATE EXACT LOCATIONS OF ALL ROOM THERMOSTATS AND/OR ROOM TEMPERATURE SENSORS WITH ARCHITECT PRIOR TO: INSTALLATION. PROVIDE A THERMOSTAT LOCATION SHOP DRAWING FOR APPROVAL MOUNT WALL THERMOSTATS AT 48' A.F.F. 18. PROVIDE A VOLUME DAMPER FOR EACH SUPPLY, RETURN, AND EXHAUST OPENING AND IN BRANCHES WHERE THREE OR MORE OPENINGS ARE ASSOCIATE) WiTH THE BRANCH AND ELSEWHERE AS NOTED ON THE DRAWINGS OR SPECIFICATIONS. 19. COORDINATE EXACT LOCATIONS OF MOUNTING HEIGHTS OF ALL PLUMBING FIXTURES WITH CASEWORK AND ARCHITECTURAL. DRAWINGS. 20. PROVIDE HJT -OFF AND CHIECK VALVES ON EACH HOT AND COLD WATER SUPPLY TO MOQNG VALVES. 21. STRUCTURAL CALCULATIORS FOR ALL MECHANICAL EQUIPMENT WEIGHTING 400 LBS OR MORE SHALL. BE PROVIDED AS PART OF THE PERMIT SUBMITTAL TO THE CITY. STRUCTURAL. CALCULATIONS SHWA. BE SIGNED AND SEALED BY A WASHINGTON STATE REGISTERED STRUCTURAL ENGINEER, FOR APPROVAL BY THE AHJ. 22. BUILDING STANDARD MATERIALS, EQUIPMENT, AND FIXTURES SHAM. BE USED ON ALL TENANT IMPROVEMENTS WITHOUT EXCEPTION. CONTRACTOR SHALL COMPLY WITH ALL APPUCABLE TENANT GUIDELINES AND STANDARDS. VICINITY MAP /LEGAL DESCRIPTION MECHANICAL INDEX OF DRAWINGS SHEET # DESCRIPTION SCALE MO.01 LEGEND NTS M1.01 MECHANICAL SCHEDULES NTS M1.02 STRUCTURAL CALCULATIONS NTS M1.03 STRUCTURAL CALCULATIONS NTS MD2.01 LEVEL 1 MECHANICAL DEMO PLAN 1/4'4-0° MD2.02 LEVEL 2 MECHANICAL DEMO PLAN MP2.OB LEVEL B MECHANICAL PIPING PLAN 1/4'4-0" M2.01 LEVEL 1 MECHANICAL PLAN 1/4°4-0° MP2.01 LEVEL 1 MECHANICAL PIPING PLAN 1/4-4-0- M2.02 LEVEL 2 MECHANICAL PLAN & CONTROLS 1/4°44" MP2.02 LEVEL 2 MECHANICAL PIPING PLAN 1/4°44 j REVIEWED FOR CODE COMPLIANCE APPROVED OCT 12 2.06 /k -,Ti � Clfy of Tukv414a DUiLDING DIVISION RECEIVED CITY OF TUKWILA► OCT 04 2016 PERMIT CENTER Legal: THIS DRAWING AND THE DESIGN HEREIN ARE THE PROPERTY OF UNIVERSITY MECHANICAL CONTRACTORS, INC. FOR THEIR USE IN CONSTRUCTION OF THIS PROJECT. NO OTHER USE SHALL BE PERMITTED WITHOUT THE WRITTEN CONSENT OF UNIVERSITY MECHANICAL CONTRACTORS, INC. V O ail 41 N � N O (3 a� 0 a� I -- w cn I-- LU n.. ai O 0) <C 00 0 z o T U. -100 o o x Q O LL U3 z d O pc o WN W< 0 o = LAJ o rn C n9 Ima o O N rn� O) N CO(O 0 0 " CN� (� 0 C X C- 0- L� (� J U-) N (� c (A z gee Q) O) a 9z UJ 0 r�UZ a W O m �a; ' �� 11 E U Z E w 3 WNEW3 a� i= OPS" V � �O of WAsy,� A C0 V Q a I �FGIST ERGO SSAONAL E� 09/26/2016 Drawn By KH Checked By RK Original Issue Date 08/24/16 Job No. 6880 Scale AS SHOWN Sheet No.. M0,01 AHU DESIGNATION AHU-01 SYSTEM CORRIDOR 104 CITY SUPPLY FAN MANUF. MODEL NUMBER CD I I MKIN LAHOOSA I 1,8DO 1 1.0 1 2,151 1 1.1 1 3 NOTES: 1. OJTSIDE AIR DUCTS SERVING INDIVIDUAL WRY AIR UNITS WITH LESS THAN 2,800 CM TOTAL SUPPLY ONLY NEED R-7 WWTION. 2. NOT REQUIRED IN UNHEATED EQUIPMENT ROOMS WITH COMBUSTION AIR LOUVERS PROVIDED THE ROOM IS ISOM FROM CONDITIONIED SPACE WITH R -I I INSULATION. I RMTE BETWEEN EXTERIOR ENVELOPE (WALL OR ROOF PENETRATION) AND ISOLATION MR 4. MINIMUM R -VALUE FOR GUM AIR DUCTS IS SAME AS FOR METAL FRAMED WALL PER TABLE C402.11. R-18 MEETS 1HIS EXTERIOR WALL REMIENT FOR CIMTE ZOO 4 AND 5. KING COUNTY IS 70NE 4C. USE R-21 FOR ZONE 6: FERRY, WNW, PEND OREILLF, AND STEVENS COUNTIES. 5 INSULATION NOT REQUIRED FOR MM WITHIN EQUIPMENT 6. FOR EXAMPLE, ABOVE CEILING PLENUMS WITH DUCTED MURN ARE CONSIDERED UNCONDITIONED SPACE; WVX MH DESIGN TEMPERATURE DIFFBEI'm BETWEEN THE INTERIOR AND EXTERIOR OF THE DUCT OR PLENUM DOES NOT EXCEED 15 F, NO INSULATION IS REQUIRED. 7. INSULATION FOR PLENUMS MALL BE THE SAME AS MOVE FOR DUCTS, DEPENDING ON SMVICE. REFER TO OUTSIDE AR MY, REM OR BMW SERVICE. B. PROVIDE ALL SERVICE ME FOR ALL DUCTS, EXCEPT PROVIDE WEATHERPROOF ALUMINUM YW FOR DUCTS OUTSIDE THE BUILDING. 9. PROVIDE VAPOR -RETARDER MASTIC ON SUPPLY AIR AND OUTSIDE AIR DUCTS 0 PLENUMS. 10. MURN AIR PLENUMS WITH PERMANENT OPENINGS TO CONMED SPACE ARE CONSIDEREI) CONDONED SPACE. CHILLED WATER AIR HANDLING UNIT SCHEDULE SCHEDULE 2' And Smaller DESIGNATION SERVICE LOCAON RETURN FAN HYDRONIC COOLING HYDRONIC HEATING COIL FINAL AIR FILTER P.D. = - (IN. WG.) !Q =E w =E INTERNAL VIBRATION ISOLATION ELECTRICAL DATA Ea C= w -Lr, ut =E c> cJ. MOTOR WEIGHT OPERATING WEIGHT (LBS) UFE. SAFETY EMERGENCY CONTROL rX. M Ce 9- MAT LAT CAPACITY U> E !T- �-=. g� Br- :2� cl: I COOK 135SQN-HP MAT [AT CAPACITY 2082 0.86 460/3 119 Q= cD R-6 BASE ISOLATION Z m m :t: m cz� �1_ m m m <55 OR >105 R-3.3 FIBERGLASS w �i I = 11 c_� - R_ : NONE NA <15 VrfFE Z 3 A3 80 65 55.2 53.9 59.7 48.9 12 45 55.1 0.21 8.00 346,8 35.0 85.5 1 99.9 17 120 108 0.11 3.90 M6.8 4- 286.2 0.2 0.4 1z MEW 8 DOWNSTREAM OF DAMPER [31 ALL R-18 [41 FIBERGLASS 460/3 MCD MOD CORE x LAY -IN ,COMPLIANT WITH 2012 WA STATE ENERGY CODE, COMMERCIAL PROVISIONS (WSEC) AND 2012 SEATTLE COMMERCIAL ENERGY CODE (SCEC) WITH UPDATES THROUGH 2015. 575.2 16X16 700 1 14 19 FdITE Z 3 AB can DIFFUSER TITUS In MW COE Sim LAY -IN BORDER TYPE 3 24x24 2OX20 1400 16 30-- VfUE Z 3 1-1/2' 2 - 00 LL.j (A Z M CHILLED WATER [4] Bi LWAR SUPPLY SLOT DIFFUSER Tam TBO-30 I -SLOT. I`W Ek Sim LAY -IN EDGE T -M 4FT LONG X 2* WIDE 6-1,4 X 5-1/4 OVAL 100 6 20 MiITE NOTES: 1. OJTSIDE AIR DUCTS SERVING INDIVIDUAL WRY AIR UNITS WITH LESS THAN 2,800 CM TOTAL SUPPLY ONLY NEED R-7 WWTION. 2. NOT REQUIRED IN UNHEATED EQUIPMENT ROOMS WITH COMBUSTION AIR LOUVERS PROVIDED THE ROOM IS ISOM FROM CONDITIONIED SPACE WITH R -I I INSULATION. I RMTE BETWEEN EXTERIOR ENVELOPE (WALL OR ROOF PENETRATION) AND ISOLATION MR 4. MINIMUM R -VALUE FOR GUM AIR DUCTS IS SAME AS FOR METAL FRAMED WALL PER TABLE C402.11. R-18 MEETS 1HIS EXTERIOR WALL REMIENT FOR CIMTE ZOO 4 AND 5. KING COUNTY IS 70NE 4C. USE R-21 FOR ZONE 6: FERRY, WNW, PEND OREILLF, AND STEVENS COUNTIES. 5 INSULATION NOT REQUIRED FOR MM WITHIN EQUIPMENT 6. FOR EXAMPLE, ABOVE CEILING PLENUMS WITH DUCTED MURN ARE CONSIDERED UNCONDITIONED SPACE; WVX MH DESIGN TEMPERATURE DIFFBEI'm BETWEEN THE INTERIOR AND EXTERIOR OF THE DUCT OR PLENUM DOES NOT EXCEED 15 F, NO INSULATION IS REQUIRED. 7. INSULATION FOR PLENUMS MALL BE THE SAME AS MOVE FOR DUCTS, DEPENDING ON SMVICE. REFER TO OUTSIDE AR MY, REM OR BMW SERVICE. B. PROVIDE ALL SERVICE ME FOR ALL DUCTS, EXCEPT PROVIDE WEATHERPROOF ALUMINUM YW FOR DUCTS OUTSIDE THE BUILDING. 9. PROVIDE VAPOR -RETARDER MASTIC ON SUPPLY AIR AND OUTSIDE AIR DUCTS 0 PLENUMS. 10. MURN AIR PLENUMS WITH PERMANENT OPENINGS TO CONMED SPACE ARE CONSIDEREI) CONDONED SPACE. FAN SCHEDULE SCHEDULE 2' And Smaller DESIGNATION SERVICE LOCAON NUMBER OF UNITS MANUFACTURER MODEL NUMBER (GREENHECK BASIS OF DESIGN) TYPE OPERATING CFM ESP (IN WG) RPM MOTOR WEIGHT TENANT EMERGENCY POWER UFE. SAFETY EMERGENCY CONTROL NOTES BHP VOLTAGE/ 'PHASE DISC. BY EC COMBO STARTER BY EC VFD BY MC (LBS) EF -1 RESTROOM DRUST FAN LEVEL I I COOK 135SQN-HP CENTRIFUGAL INLINE 1,300 2 2082 0.86 460/3 119 ALL R-6 FIBERGLASS X OUTSIDE THE BUILDING ALL R-8 FIBERGLASS TIM CONDITIONED SPACE <55 OR >105 R-3.3 FIBERGLASS BED TYPE 3 CONDITIONED SPACE 55-105 NONE NA <15 VrfFE Z 3 A3 COLN DIFFUSER REIURN AIR [5,61 NOTES: ALL R-6 [6] FIBERGIASS NOTES: 1. OJTSIDE AIR DUCTS SERVING INDIVIDUAL WRY AIR UNITS WITH LESS THAN 2,800 CM TOTAL SUPPLY ONLY NEED R-7 WWTION. 2. NOT REQUIRED IN UNHEATED EQUIPMENT ROOMS WITH COMBUSTION AIR LOUVERS PROVIDED THE ROOM IS ISOM FROM CONDITIONIED SPACE WITH R -I I INSULATION. I RMTE BETWEEN EXTERIOR ENVELOPE (WALL OR ROOF PENETRATION) AND ISOLATION MR 4. MINIMUM R -VALUE FOR GUM AIR DUCTS IS SAME AS FOR METAL FRAMED WALL PER TABLE C402.11. R-18 MEETS 1HIS EXTERIOR WALL REMIENT FOR CIMTE ZOO 4 AND 5. KING COUNTY IS 70NE 4C. USE R-21 FOR ZONE 6: FERRY, WNW, PEND OREILLF, AND STEVENS COUNTIES. 5 INSULATION NOT REQUIRED FOR MM WITHIN EQUIPMENT 6. FOR EXAMPLE, ABOVE CEILING PLENUMS WITH DUCTED MURN ARE CONSIDERED UNCONDITIONED SPACE; WVX MH DESIGN TEMPERATURE DIFFBEI'm BETWEEN THE INTERIOR AND EXTERIOR OF THE DUCT OR PLENUM DOES NOT EXCEED 15 F, NO INSULATION IS REQUIRED. 7. INSULATION FOR PLENUMS MALL BE THE SAME AS MOVE FOR DUCTS, DEPENDING ON SMVICE. REFER TO OUTSIDE AR MY, REM OR BMW SERVICE. B. PROVIDE ALL SERVICE ME FOR ALL DUCTS, EXCEPT PROVIDE WEATHERPROOF ALUMINUM YW FOR DUCTS OUTSIDE THE BUILDING. 9. PROVIDE VAPOR -RETARDER MASTIC ON SUPPLY AIR AND OUTSIDE AIR DUCTS 0 PLENUMS. 10. MURN AIR PLENUMS WITH PERMANENT OPENINGS TO CONMED SPACE ARE CONSIDEREI) CONDONED SPACE. DUCT INSULATION SCHEDULE 2' And Smaller ThL 2-1 L2 o" DUCT TYPE [7,8] LOCATION TEMP RANGE (DEGREES F) INSULATION R -VALUE REQUIREMENT INSULATION TYPE Pipe. Sch 40 Blk A530 ERW (Up to 101, Pipe, Sid Wt Blk A539 ERW (12' And. Larger) JOINT TYPE Swt - Leod-Free Solder, Silvabride 100 EQUIP. 0) NO. sow OUTSIDE AIR [1,2,91 UPSTREAM OF DAMPER [3] ALL R-18 [41 FIBERGLASS FRAME MODE DOWNSTREAM OF DAMPER, UNCONDITIONED SPACE ALL R-6 FIBERGLASS NC DOWNSTREAM OF DAMPER, CONDITIONED SPACE ALL R-8 FIBERGLASS TITUS NCO MOD CORE STEEL LAY -IN SUPPLY AIR [5,6,9] UNCONDITIONED SPACE ALL R-6 FIBERGLASS <15 OUTSIDE THE BUILDING ALL R-8 FIBERGLASS TIM CONDITIONED SPACE <55 OR >105 R-3.3 FIBERGLASS BED TYPE 3 CONDITIONED SPACE 55-105 NONE NA <15 VrfFE Z 3 A3 COLN DIFFUSER REIURN AIR [5,61 UNCONDITIONED SPACE ALL R-6 [6] FIBERGIASS BUM TYPE 3 CONDITIONED SPACE NA NONE [10] NA <15 OLffSIDE THE BUILDING ALL R-8 FIBERGLASS TIM MCD IN CORE STEEL LAY -IN OMST AIR UPSTREAM OF DAMPER ALL NONE 1z 18 DOWNSTREAM OF DAMPER [31 ALL R-18 [41 FIBERGLASS TITUS MCD MOD CORE Sim LAY -IN ,COMPLIANT WITH 2012 WA STATE ENERGY CODE, COMMERCIAL PROVISIONS (WSEC) AND 2012 SEATTLE COMMERCIAL ENERGY CODE (SCEC) WITH UPDATES THROUGH 2015. 24x24 NOTES: 1. OJTSIDE AIR DUCTS SERVING INDIVIDUAL WRY AIR UNITS WITH LESS THAN 2,800 CM TOTAL SUPPLY ONLY NEED R-7 WWTION. 2. NOT REQUIRED IN UNHEATED EQUIPMENT ROOMS WITH COMBUSTION AIR LOUVERS PROVIDED THE ROOM IS ISOM FROM CONDITIONIED SPACE WITH R -I I INSULATION. I RMTE BETWEEN EXTERIOR ENVELOPE (WALL OR ROOF PENETRATION) AND ISOLATION MR 4. MINIMUM R -VALUE FOR GUM AIR DUCTS IS SAME AS FOR METAL FRAMED WALL PER TABLE C402.11. R-18 MEETS 1HIS EXTERIOR WALL REMIENT FOR CIMTE ZOO 4 AND 5. KING COUNTY IS 70NE 4C. USE R-21 FOR ZONE 6: FERRY, WNW, PEND OREILLF, AND STEVENS COUNTIES. 5 INSULATION NOT REQUIRED FOR MM WITHIN EQUIPMENT 6. FOR EXAMPLE, ABOVE CEILING PLENUMS WITH DUCTED MURN ARE CONSIDERED UNCONDITIONED SPACE; WVX MH DESIGN TEMPERATURE DIFFBEI'm BETWEEN THE INTERIOR AND EXTERIOR OF THE DUCT OR PLENUM DOES NOT EXCEED 15 F, NO INSULATION IS REQUIRED. 7. INSULATION FOR PLENUMS MALL BE THE SAME AS MOVE FOR DUCTS, DEPENDING ON SMVICE. REFER TO OUTSIDE AR MY, REM OR BMW SERVICE. B. PROVIDE ALL SERVICE ME FOR ALL DUCTS, EXCEPT PROVIDE WEATHERPROOF ALUMINUM YW FOR DUCTS OUTSIDE THE BUILDING. 9. PROVIDE VAPOR -RETARDER MASTIC ON SUPPLY AIR AND OUTSIDE AIR DUCTS 0 PLENUMS. 10. MURN AIR PLENUMS WITH PERMANENT OPENINGS TO CONMED SPACE ARE CONSIDEREI) CONDONED SPACE. PIPE INSULATION SCHEDULE CHILLED WATER SUPPLY AND RETURN ITEMS 2' And Smaller ThL 2-1 L2 o" GRILLE, REGISTER AND DIFFUSER SCHEDULE INSULATION TYPE VAPOR BARRIER REQUIRED? PIPE MATERIALS Pipe, Copper Type L B88 Pipe. Sch 40 Blk A530 ERW (Up to 101, Pipe, Sid Wt Blk A539 ERW (12' And. Larger) JOINT TYPE Swt - Leod-Free Solder, Silvabride 100 EQUIP. 0) NO. sow MANUFACRW I%& STYLE MATERk FRAME FRAME MODE DESCRIPTION FACE SEE NECI( S[ZE UAX 99 Raw NC COLOR NOTES At CEILING DIFFUSER TITUS NCO MOD CORE STEEL LAY -IN BORDER TYPE 3 24x24 W 100 6 <15 ViITE Z 3 A2 CEILING DIFFUSER TIM Mco MOD CORE STEEL LAY -111 BED TYPE 3 24x24 1OXIO 210 8 <15 VrfFE Z 3 A3 COLN DIFFUSER TITUS MCD I% CORE Sim LAY -11 BUM TYPE 3 24x24 12X12 375 10 <15 WHffE Z 3 A4 CUM DIFFUSER TIM MCD IN CORE STEEL LAY -IN BUM TYPE3 24)Q4 1014 550 1z 18 M. 2.3 A5 CEILING DIFFUSER TITUS MCD MOD CORE Sim LAY -IN BORDER TYPE 3 24x24 16X16 700 1 14 19 FdITE Z 3 AB can DIFFUSER TITUS In MW COE Sim LAY -IN BORDER TYPE 3 24x24 2OX20 1400 16 30-- VfUE Z 3 1-1/2' 2 - 00 LL.j (A Z M CHILLED WATER [4] Bi LWAR SUPPLY SLOT DIFFUSER Tam TBO-30 I -SLOT. I`W Ek Sim LAY -IN EDGE T -M 4FT LONG X 2* WIDE 6-1,4 X 5-1/4 OVAL 100 6 20 MiITE 4 B2 LINEAR MY SLOT DIFFUSER TITUS ED -30 2 -SLOT, I -W EL STEEL LAY -IN EDGE T -BARS 4Ff LONG X 4* WIDE 9-318 X 5-1/4 OVAL 210 8 23 WHITE 4 83 UTAR SURKY SLOT DIFFUSER TITUS TBO-30 3 -SLOT, I' W Ek STEEL LAY -IN EDGE T -BARS 41`17 LONG X C WIDE 12-1/2 X 5�1/4 OVAL 32D to 25 WHITE 4 B4 LINEAR SLMY SLOT DIFFUSER TIM TBD -30 4 -SLOT, 1-W Ek Sim LAY -IN EDGE T -BARS 4Fr LONG X 8' WIDE 15-5t8 X 5-1/4 OVAL 425 12 26 WHITE 4 2-1/2' 2-1/2' 3. 3. 1 C1 RETM GRILLE TITUS 5OF EGGCRATE ALUMINUM LAY -IN BOW TYPE 1 2402 22XIO 600 PER PLAN <12 MfTE 1.2 C2 RETURN GRILLE TITUS 5OF EGGCRATE ALLIMINUM LAY -IN BORDER TYPEI 24x24 M 1200 PER PLAN <12 Mff 1,2 C3 RETM GRILLE THUS 5OF EGGCRATE ALUMINUM LAY -IN BUM TYPE I 24x48 22X46 2400 PER PLAN <12 Wiff 1, 2 C4 RETURN GRILLE TITUS 5OF EGGCFATE ALUMINUM SURFACE BORDER TYPE 3 2644 2012 ISDO PER PLAN <12 M 1,2 NO F 3' 4* 4-1/2' 4-1/2' 4-1/2* DI OHM GRILLE TITLIS 35ORL SINGLE DEF Sim SURFACE BOW TYPE I 10XIO 300 100 6 <10 3' 3- D2 DMIST GRILLE TIM Y)ORIL SINGLE DEF I Sim SURFACE BORDER TYPE1 1 12X12 1OXIO 210 8 <10 D3 MIAUST GRILLE TITUS I 35ORL SINGLE DEF Sim 11"111 BORDER TYPE 1 1014 I= 375 10 10 *UE D4 MKIST gaff TITUS 3M SINGLE DEF STEEL SURFACE BOW TYPE I I6X16 :J 1014 550 12 27 WIM ALL 0.20 - 0.26 75 ELASTOMERIC YES H 1/2' [6] 1/2' [6] NOTES* 1. PROVIDE RENLIM CAN FOR DUCTED SYSIEM IN CEILING APPLICATION (NOT EQUIRED FOR SIDEN.L APPLICATION); OR PROVIDE SOUND BOOT 9 N)ICATED ON PLANS. 2. DffUSER OR GRILLE MAY ALSO BE USED FOR HARDLID APPLICATIONS WtIERE A TITUS `TRM' RAM MOUNT FRAME IS MM, FRAME AS INDICATED ON RAE TRY PROVE ACCESS ABOVE CMN. 3. FOR LIMITED CEILING HMff APPLICATIONS, PROVIDE PLENUM CAN WITH BRANCH DUCT SIZED SIDE RLT, OMWtSE PROVIDE SQUARE TO ROUND TIRNNSITION WITH BRANCH DUCT SIZED TOP HE 4. FACTORY INSULATED PLENUM CAN PROVIDED WITH DIFFUSER COMPLIANT WITH 2012 WA STATE ENERGY CODEJ COMMERCIAL PROVISIONS (WSEC) AND 2012 SEATTLE COMME PIPE INSULATION SCHEDULE CHILLED WATER SUPPLY AND RETURN ITEMS 2' And Smaller ThL 2-1 L2 o" MEAN RATNG TEMP (DEGREES 0 INSULATION TYPE VAPOR BARRIER REQUIRED? PIPE MATERIALS Pipe, Copper Type L B88 Pipe. Sch 40 Blk A530 ERW (Up to 101, Pipe, Sid Wt Blk A539 ERW (12' And. Larger) JOINT TYPE Swt - Leod-Free Solder, Silvabride 100 9W FITTING MATERIAL Wrot Copper B16.22 Std Wt A234 WPB B16.9 BRANCH TAKEOFF Threod-O-Let, 30001 FS Blk, T -Drill Type 2 Bronchlet, Std Wt A106B SMLS FLANGES 1501 Swt Companion Flange, Cost Bronze 016.24 1501 WN Flange, A105 Std Wt B16.5 GASKETS Gasket. 1/8' Non -Asbestos Ring, B16.21 Gasket, 1/8' Non -Asbestos Ring, B16.21 BOLT TYPE Bolts, A307 Grade B Plated Bolts, A307 Grade B Plated DOMESTIC COLD NON -POTABLE COLD ALL 0.21 - 0.27 VALVES FIBERGLASS YES [11] BALL VALVES: SWT 1501 Boll Valve, Two -Piece Full Port SP -110 Bmz Swt - Nibco S-585-70 N/A Ir 1-1/2* GATE VALVES: THD FLG N/A 1251 Gate Valve, Bolted Bonnet OS&Y Solid Wedge SP -70 Cl Aq - Nibco F-617-0 (Exclude From Fill) Uj GLOBE VALVES: THO / FLG 1251 Globe Valve, Screw-in Bonnet Integral Seat SP -80 Bmz Thd - Nibco T -211-Y 1251 Globe Valve, Bolted Bonnet SP -85 Cl ng - Nibco F -718-B BUITERFLY VALVES: LUG NIA 2001 Butterfly Valve, SP -67 DI Lug Style - Nibco LD-2DOO (Up to 121 105-140 0.21 - 0.28 1501 Butterfly Valve, SP -67 DI Lug Style - Nibco LD -1000 (14! And Larger) FIBERGLASS NO SWING CHECK VALVES: THD FLG 1251 Check Valve, Horizontal SWing Y-Pottem SP -80 Bmz Thd - Nibco T -413-B 1251 Check Valve, Horizontal Swing Bolted Bonnet SP -71 Ci Ag - Nbico F -918-B 1-1/2' 1-1/2' C:) (0 (Z) C14 N -S WAFER CHECK: 1251 Ring Check Valve, Inline Lift Spring Actuated Bmz Thd - Nibco T-480 1251 Check Valve, Wafer Sye Spring Actuated SP -125 Ct - Nibco W-910 COY')) F4 < CIRCUIT BAL VALVE. THD / FLG 3001 Circuit Balancing Valve, Y- Pattern Bmz Thd - TA Hydronics 787 1251 Circuit Balancing Valve, Y- Pattern 01 Ag - TA Hydronics 788 to n SPECIALTIES STORM DRAIN ALL DIELECTRIC WATERWAYS Dielectric Nipple, Bmz (LF) Thd x Thd - Victoulic 647 -TT N/A PRESSURE RELIEF Pressure Relief Valve, CS Thd - Kunkle 910 Pressure Relief Valve, CS Thd - Kunkle 910 STRAINER, Y -PATTERN 1251 Strainer, Y -Pattern Bmz Thd - Mueller 351M 1251 Strainer, Y-Pattem Ct FIg - Mueller 758 PRESSURE GAUGE 0-1001 Pressure Gouge, Aluminum Case, Bmz Thd - Weiss 4PG-Nl Pressure Gauge, Aluminum Case, Bmz Thd - Weiss 4PG-Nl THERMOMEFER Thermometer, 9'Scale, 3-1/2' Stem, Variable Angle Thd - Weiss 9VU35-24O Thermometer, 9Scale, 3-1/2' Stem, Variable Angle Thd Weiss 9VU35-240 0 L2 HEATING WATER [4) HEATING WATER - LOW TEMP HEATING WATER - HIGH TEMP NOTES: 1 - Copper - Use 'Branch Takeoff* in lieu of fitting if branch piping is 1 sizes less than main or more. Example; Use 1-1/2* T-Dnll in lieu of 2'xl-1/2' Tee. 2 - Carbon Steel - Use *Branch Takeoff* in rieu of fitting if branch piping is 2 sizes less than main or more. Example; Use 2-1/1' shaped nipple (saddle) in lieu of 42-1/2" Tee. PIPE INSULATION SCHEDULE INSULATION SPEC PIPING SYSTEM TEMP RANGE (DEGREES F) CONDUCTIVITY BTU -IN/ (&Fr^2-0 MEAN RATNG TEMP (DEGREES 0 INSULATION TYPE VAPOR BARRIER REQUIRED? PIPE INSERT NOTE PIPE SIZE 1' TO <1 1/2' 1 11f To <4' 4' TO <8* 8*&oVER Z 00 C 0 1jL 00 0) DOMES11C COLD DOMESTIC COLD NON -POTABLE COLD ALL 0.21 - 0.27 75 FIBERGLASS YES [11] A 1/2' [6] 1/2' [61 Ir 1-1/2* La Uj 0 Uj < DOMESTIC HOT [1] DOMESTIC HOT NON -POTABLE HOT 105-140 0.21 - 0.28 100 FIBERGLASS NO 0 1-1/2' 1-1/2' 1-1/2' C:) (0 (Z) C14 COY')) F4 < to n STORM DRAIN [2,31 STORM DRAIN ALL 0.21 - 0.27 75 FIBERGLASS YES [111 B 1. 1. 1. 1. 1. 0 L2 HEATING WATER [4) HEATING WATER - LOW TEMP HEATING WATER - HIGH TEMP 105-140 141-200 0.21 - 0.28 0.25 - 0.29 100 125 FIBERGLASS FIBERGLASS NO NO C C 1. 1-1/2* 1. 1-1/2' 1-1/2' 2- 1-1/2* 2 1-1/2' 2 - 00 LL.j (A Z M CHILLED WATER [4] CHILLED NATER 40-60 0.21 - 0.27 75 FIBERGLASS YES D 1/2' [6] 1/2' [6] 1. 1. 1. E CONDENSER WATER [4,5] CONDENSEE WATER 40-60 0.21 - 0.27 75 FIBERGLASS YES [7] E 1/2' [6] 1/2' [6] 1. f 1. LU LOW PRESSURE STEAM STEAM - LOW PRESSURE 201-250 (0-151) 0.27 - 0.30 150 FIBERGLASS NO F 2-1/2' 2-1/2' 2-1/2' 3. 3. MED/HIGH PRESSURE STEAM STEAM - MED/HGH PRESSURE STEAM - HICH PRESS 251-350 (16-1201) >350 (>120P 0.29 - 0.32 0.32 - 0.34 200 250 FIBERGLASS FIBERGLASS NO NO F F 3- 4-1/2' 4' 5- 4-1/2' 5- 4-1/2' 51 4-1/2' 5 - STEAM CONDENSATE -LOW CONDENSATE - LON/MED TEMP <250 0.27 - 0.30 150 FIBERGLASS NO F 2-1/2' 2-1/2' 2-1/2' 3- 3 - STEAM CONDESTE-HIGH CONDENSATE - HIGH TENP >250 0.29 - 0.32 250 FIBERGLASS NO F 3' 4* 4-1/2' 4-1/2' 4-1/2* GENERATOR DRUST [8] GENERATOR DMUST UP TO 1100 0.45 300 CAL -SIL NO G 3' 3- 3- 3- 3 - REFRIGERATION [91 REFRIGERATIO11 SUCTION <40 0.20 - 0.26 75 ELASTOMERIC YES H 1/2' [6] 1. 1, 1, CONDENSATE DRAIN [10] COIL CONDENSATE DRAIN ALL 0.20 - 0.26 75 ELASTOMERIC YES H 1/2' [6] 1/2' [6] COMPLIANT WITH 2012 WA STATE ENERGY CODEJ COMMERCIAL PROVISIONS (WSEC) AND 2012 SEATTLE COMME ?CIAL ENERGY CODE (SCE� WITH UPDATES THROUGH 12015. 1 1 - I i NOTES: 1. MOM DOMESTIC HOT WATER RECIRCULATION PIPING. DO NOT USE RSERTS - INSUTE AROUND HMGER (INC STANDARD) 2. INSULATE ALL HORIZONTAL STORM DRAIN PIPING 16WO IN CONDITIM SPACE. DICULIDING PIPING FROM LOWER ROOFS AND DEOM MUTE ROOF DRAIN BODIES. (UMC SWIDARD) 3 INSULAEE FIRST 20 FEET OF HORIZONTAL OVERFLOW STORY DIRM PM INSIALLED IN CONDITIoNED SPACE, WJUE PIPING FROM WO ROOFS AND DECM INSLILATE ROOF DRAIN BODIES, (UMC STAN11%) t PIPING THAT 6 PART OF A HFATING OR COOLING SYSTEM ODNOM FWIDS BETWEEN 60 F RD 105 F DOES NOT REQUIRE INSULITION. (WSEC 2012) 5. IF DXSED CONDENSER WATER PIPING IS USED FOR HEM AND IS I]ETWEEN 60 F AND 105 F, NSULATE ALL MOVEI) PIPE 00 Wr NOT THE PIPE RUN - IN OCCUPIED AREAS ONLY. 6. MINIMUM TICIONESS OF 1/f IS REQUIRED of CODE FOR THIS PIPE SIZE. I- THU MULAE104 6 ALSO ACCEPIABLE AT NO ADDED COST IF PREFERRED BY SUBCONTRACTOR. 7. VAPOR BARRIER REQUIRED ONLY IF CONDENSER WATER IS 60 F OR BROW & GENERATOR OHM INSULATION IS FOR PERSONNEL PROTECTION - MWESS 6 NOT DRIVEN BY ENERGY CODE 9 VERIFY REQUIREMENTS FOR REFRIGERANT SUCTION LINES FOR EACH OLICAMI. to INSULATE COIL CONMISATE PIPING *01 LOCATED IN CONDITIONED SPACE OR ABOVE CMING OF COND7)ONE]) SPACE. It. IT IS ACCEPTABLE FOR HANGER TO PENETRATE VAPOR BMW AT TOP OF PIPE FOR COLD WER AND STORY DRAIN SI(STEMS. .......... .................. ... . .......... . 61111 .. .. ...... ... ,g Selection Info A ""I",""�"I",""""""""ll""IllI .............. ........... q 1? H/C/B CFM 3 50 401f AX B 1815 0 1� . ............ "I M 36 50 B 45 w� w W, 0 0 4 140", 50 8 45 p 8 5 U 115 50 tiz 52 0 All".," V 7V 50 a 176 50 B 176 0 "',"'a, M - ....... . .. 195 "", . . ... ..... 0 195 mw 0 Peak Totals 24,645 5,194 1,121 1,121 1 29,375 0 1,815 29,375 F_ 2.433 7 - PEAK OSA MAX % IN % IN % MAX % MAX % MAX % hN % IS REVIEWED FOR OCT 12 2016 QtV Of Tutwila U1 _112ING DIVISION RECEIVED CITY OF TUKWILA NOTES Lego 1: UNIVERSITY MECHANICAL CONTRACTORS, INC. FOR THEIR USE IN CONSTRUCTION OF THIS PROJECT. NO OTHER USE SHALL BE PERMITTED WITHOUT THE WRITTEN CONSENT OF UNIVERSITY MECHANICAL CONTRACTORS, INC. 1.0 Q) V_ _+1 0 0 CN 0, LU LU Q_ (3 U) o <<<<<<< i /()NAI- 'V�� Drawn By KH Checked By RK I I e a e Job No. 6880 Sheet No. M101 Z cl) 0 Z 00 C 0 1jL 00 0) L_ E X LL Uj Z< 0 0 Ir La Uj 0 Uj < Uj 0 L_ Lu -00 0 C: 3. a_ 0 C:) (0 (Z) C14 COY')) F4 < to n Lij C�l CD C14 04 F_ 0 L2 LU F_ CD Lr) 0 j cc r- �C,4 Z 00 LL.j (A Z M LLJ Uj r >, Z Z Uj 0 E 0 < E LU i /()NAI- 'V�� Drawn By KH Checked By RK I I e a e Job No. 6880 Sheet No. M101 1/2" DIA HILTI KWIK BOLT TZ, (E) 3" CONC OVER 3" MTL EMBED 3 5/8' TYP DECK (TYPE W) Attachment to Structural Steel 4' Min. P2785 0-16 8earn Clamp -------------------------------- --- — — — — — — — — MECH UNIT 0 Pi 000 UNISTRUT P1000 BRACING PER PLAN 3" MIN i 3° MIN PSO10 Hut vrith 45 Max. 4 :: HHcs HHCS 1/2' DIA .----- \ UNISTRUT P1000T P1843w Hinge VIBRATION ISOLATOR (BY OTHERS) P1000 Transverse or `' r Longitudinal Brace L3X3X1/4"' UNIT SUPPORT 1/2" DIA THREADED ROD C3X6 UNIT SUPPORT MAX SEISMIC BRACING TO EXISTING STEEL BEAM SEISMIC BRACING TO UNIT SUPPORT ANGLE Drawing By unistrut NTS NTS THREADED ROD TO EXISTING CONCRETE OVER MTL DECK NTS 1 CRITERIA 1. ALL MATERIALS, WORKMANSHIP, DESIGN, AND CONSTRUCTION SHALL CONFORM TO THE DRAWINGS, SPECIFICATIONS, AND THE 2012 SEATTLE BUILDING CODE. 2. DESIGN LOADING CRITERIA: a , MECHANICAL UNITS . . . . . . . . . . WEIGHTS FURNISHED BY MANUFACTURER ........ ............. I j N EARTHQUAKE ANALYSIS PROCEDURE: NONSTRUCTURAL COMPONENT DESIGN Spring Isolators SITE CLASS=D, SS=1.512, Sds=1.01, S1=0.58, SD1=0.58 SDC D, IP=1.0, RP=6.0, Ap 2.5 �— ANCHOR PER DETAIL 1/S1.0,TYP _ 19 t SEE PLANS FOR ADDITIONAL LOADING CRITERIA r (E) W1 8X40 3. CONTRACTOR SHALL BE RESPONSIBLE FOR ALL SAFETY PRECAUTIONS AND THE ! METHODS, TECHNIQUES, SEQUENCES OR PROCEDURES REQUIRED TO PERFORM THE 1/2' DIA THREADED ROD,TYP SUSPENDED CONTRACTORS WORK. THE STRUCTURAL ENGINEER HAS NO OVERALL SUPERVISORY MECHAMCALIUNIT; i AUTHORITY OR ACTUAL AND/OR DIRECT RESPONSIBILITY FOR THE SPECIFIC WORKING i CONDITIONS AT THE SITE AND/OR FOR ANY HAZARDS RESULTING FROM THE ACTIONS _ 8OOLEIS :MAXWEIGF(f OF ANY TRADE CONTRACTOR. THE STRUCTURAL ENGINEER HAS NO DUTY TO INSPECT, M P1aaa SUPERVISE, NOTE, CORRECT, OR REPORT ANY HEALTH OR SAFETY DEFICIENCIES TO rr THE OWNER, CONTRACTORS, OR OTHER fiNTITIES OR PERSONS AT THE PROJECT SITE. w Q — - C3X6 v ;� ANCHORAGE i ; UNISTRUT P1000 BRACING PER PLAN TO C3 LU ± T ; (E) STEEL BEAMS PER 3/S1.0, TYP cxo v; ; x 3 i o ®� 4 X- _ i m t i v 4. EXPANSION BOLTS INTO CONCRETE AND CONCRETE MASONRY UNITS SHALL BE "KWIK r, " w w Ll C3X6 t J tv) .�– __________�_w�___ �._. _ . _ .. P1000 ._... BOLT TZ" AS MANUFACTURED BY THE HILTI CORP., INSTALLED IN sTRlcr � L3X3X1/4 _.: o,.: � ACCORDANCE WITH ICC -ES REPORT NO. ESR -1917, INCLUDING MINIMUM EMBEDMENT t� w REQUIREMENTS. BOLTS INTO CONCRETE MASONRY OR BRICK MASONRY UNITS SHALL BE INTO FULLY GROUTED CELLS. SUBSTITUTES PROPOSED BY CONTRACTOR SHALL BE 0 0c SUBMITTED FOR REVIEW WITH .ICC REPORTS INDICATING EQUIVALENT OR GREATER LOAD CAPACITIES. SPECIAL INSPECTION IS REQUIRED FOR ALL EXPANSION BOLT ? EXTEND L3X3 FOR SEISMIC BRACING AS REVD, Q W14X26 n INSTALLATION. CONNECT PER DETAIL 2/S1.0 STEEL 03X6 5. STRUCTURAL STEEL SHALL CONFORM TO THE FOLLOWING REQUIREMENTS: ` C channels are required on all units. On unit sizes 007 and above, L -channels Q W1 022 on both ends are also required. TYPE OF MEMBER ASTM SPECIFICATION- FY A. WIDE FLANGE SHAPES A992 50 KSI ( C B. OTHER SHAPES, PLATES, AND RODS A36 36 xsI MECHANICAL UNIT SUPPORT I TAMING C. OTHER SHAPES AND PLATES A572 (GRADE 50) 50 KSI y LEVEL 2 MECHANICAL UNIT SUPPORT FRAMING PLAN (NOTED GRADE 50 ON PLANS) Drawing from Manufacturer, With Added Info b 5SF NTS D. PIPE COLUMNS A53 (E OR S, GR.B) 35 KSI N i S. STRUCTURAL TUBING A500 (GR.B) OR ASTM A1085 y 1/4"=1'-0" -SQUARE OR RECTANGULAR 46 KSI -ROUND 42 KSI { s 1 0/EM IIMCWML GI 2t24 Third Avenue - Suite tao - Seattle, WA 98121 p: 2o6.443.62t2 ssfengineers.com - Copyright 2015 Swensm Say Fagg - AR Rights 9/21/2016 DRAWN: EBG DESIGN: EBG CHECKED: ABB APPROVED: ABB REVISIONS: DPO: PROJECT TIRE: MUSEUM OF FLIGHT RESTROOM EXPANSION MECHANICAL UNIT SUPPORT 9404 E MARGINAL WAY. S SEATTLE, INA 98108: ARCHITECT: SH..KSAR.CHITECT'S 1050 N.38th St, 5eaWe. WA 98103> r r 206 676,9151 :'ti't.'N?Siiic53fCt=tBC?S.CC'R - ISSUE: PERMIT ;HEFT TIRE: MECHANICAL UNIT. STRUCTURAL SUPPORT ;CALF: VARIES )ATE: 9/21/2016 IROJECT NO: 00099-2016-07 HEFT NO: S .0 10: OF SHEETS: ECEIVED CITY OF TUKWILA OCT 042016 MM I 157(o PERMIT CENTER REVIEWED FOR CODE COMPLIANCE APPROVED OCT 12 2016 City ©f Tukwila BUILDING DIVISION Legal: THIS DRAWING AND THE DESIGN HEREIN ARE THE PROPERTY OF UNIVERSITY MECHANICAL CONTRACTORS, INC. FOR THEIR USE IN CONSTRUCTION OF THIS PROJECT. NO OTHER USE SHALL BE PERMITTED WITHOUT THE WRITTEN CONSENT OF UNIVERSITY MECHANICAL CONTRACTORS, INC. F— W u'1 Cie H W CL 6 N o z 0000000 Drawn By C Checked By RK Original Issue Date 4� �Z Job No. 6880 Scale V Z ' c o J OC 0 x Z� LU a 0 0 .� N �W 0 0 W p �Q I— rW� Q) LU ami et W LL O o- o c::) (D O CV rn — cD cD M r� (D(D 4 0 X 0— LL_ w+ Ln J c00 CV Z OC O N 0 LL U O1 Z _O C CL V iWi�— Vis' J�,/ � t� m m 5 V/r� cD E 0 U ZD c 3 F.— 3 Cr) Q) Drawn By KH Checked By RK Original Issue Date 08/24/16 Job No. 6880 Scale AS SHOWN Sheet No. M1.02 W Structural Calculations for: Museum of Flight Restroom Expansion Mechanical Unit Support 5404 E Marginal Way S Seattle, WA 98108 9/21/2016 Prepared for: SHKS Architects Job #: 00099-2016-07 Date: September 21, 2016 59A B 21247trrdAve:bu e1G0.5. 7tzt t:Aa3}2i 0 206.44967f2 c',rirt3e is;c�r - 7itCOME4 X34Or. oad>"r;:y,..$u�:etL�O. T5K0'h4,lY`A.9$403 0 2�3.26q;1470 _Mechanical Unit Support Summary: New mechanical unit to be suspended below existing floor. Criteria: Existing Floor Live Load (Office) = 50psf + 15psf partitions Existing Floor Dead Load = 65 psf (3" NW Conc on 3" W3 Deck + 10psf misc.) Mechanical unit weights = 575lbs per Mechanical Drawings, add 225 lbs for frame/mise. Seismic= (see attached USGS ground motion parameters) Gravity Framing: Check existing concrete over metal deck with added unit weight: P P w I P = 200 lbs @ Third Pts w (super) = 65psf LL +10 psf DL (superimposed) n L= 10.5' Mmax=1734 ft -lbs 3" NW Over 20ga W3 Deck: Allowable Superimposed Load=150psf (single span) Mmax < M. equiv -> OK M,equivalent = 2067 ft-lbs/ft (E) Conc Deck is OK w/ Added Loading Seismic Bracing: Design for Fp = 0.4apSdsWp/(R/1) (1+2z/h) = 0.4(2.5)(1.01)Wp/(6/1.0)(1t2) = 0.51Wp Fp= 0.51Wp = 0.51(800lbs) = 408 lbs Max brace force = 300 lbs. P1000 Pa = -2200 lbs @ L= 6ft -> OK Model Axial (0.9D+E) Design 9r2016 Design Maps Srnmary Report MUM Design Maps Summary Report User -Specified Input Building Code Reference Document 2012/2015 International Building Code (which utilizes USGS hazard data available In 2008) Site Coordinates 47.529080N, 122.30491°W Site Soil Classification Site pass D - "Stiff Soil' Risk Category LWIII USGS-Provided Output Ss = 1.512 g Sas = 1.512 g Sos = 1.008 g S, = . 0.576 g S,4i = 0.864 g Sol = 0.576 g For information on how the SS and S1 values above have been calculated from probabilistic (risk -targeted) and deterministic ground motions in the direction of maximum horizontal response, please return to the application and select the '2009 NEHRP' building code reference document. MCE,L Response Spectrum Design Response Spectrum 1.36 1.10- 0.93 .10 0.93 aea - 1.12 an Os6 - a66 N a80 N 0.55 O.0 au 0.48 a33 0.22- 0.16-- .32 ai6 all 0.00 D.00 0.00 0.20 0.40 0.60 0.80 1.00 1.20 1.40 1.60 1.80 2.00 - 0.00 0.20 0.40 0.60 012 1.00 1.20 1.40 1.60 1.80 2.00 Period T (sac) Period, T (sect Although this information is a product of the U.S. Geological Survey, we provide no warranty, expressed or implied, as to the accuracy of the data contained therein. This tool is not a substitute for technical subject -matter knowledge. 2of4 hftNfehp2-oa-tquakewr.tsgs.gov/desigmapsAWsLimmaryptp7templats=mirtmal&lafiWdEF=47. 46G&loVWde=-12230490 lMl78 siWms=... 111 Technical Data Sheet for Destiny 001 Job Number. ZZCP2J Page Prepared Date: 3 ot8l`31/2016 Job Name: MUSEUM OF FLIGHT 14 of 17 www.DaikinApplied.com Ifiswidij-'C66ilijilibbrit Channel - iii 1 §$' 413 �§• • 9S 22.2 9S sem. i .915' '� 2 J� 233 T1 41.113 + 1 1 - .710' t 1 - 2 COLUMN LOADING - P1000 BEAM LOADING - P1000 Naifmam ; Bea. at 24 (610) i►fill codJtilawitIle Load hlaiininm Cafama Load kirpiied at Haig#1 'at5lotEaca- :R 60 (1524) K=1,2 11.50 1118 2,230 9.50 24 . 24 3,450 10,750 9,900 8,770 7,730 36 3,050 8,910 7,730 6,370 5,280 48 2,660 7,250 .5,980 4,660 3,770 60 2,290 5,890 4,660 3,600 2,940 72 2,000 4,800 3,770 2,940 2,380 84 1,760 4,010 3,170 2,460 1,970 96 1,570 3,450 2,730 2,090 1,650 108 1,410 3,020 2,380 1,800 340 120 1,270 2,680 2,090 - •' BEAM LOADING - P1000 P1000 BRACE DESIGN LOAD 0n8t1ppnded Length : -. a ; Bea. at 24 (610) 4,200 hllmvable Uni(atmthittang Loadlant at 0e6eIlion 16.00 Spsn tlalfom# load "load Pon/1814: �anJ24(1 `, Spanl300 60 (1524) 2,650 11.50 72 (1829) 2,230 9.50 24 1,690 0.06. 1,690 1,690 1,690 36 1,130 0.13 1,130 1,130 900 48 850 0.22 850 760 510 60 680 0.35 650 490 320 72 560 0.50 450 340 220 84 480 0.68 330 250 170 96 420 0.89 250 190 130 108 380 1.13 200 150 100 120 340 1.40 160 120 80 144 280 2.01 110 80 60 168 240 2.74 80 60 40 192 210 3.57 60 50 NR 216 190 4.52 50 40 NR 240 170 5.58 40 NR NR P1000 BRACE DESIGN LOAD 0n8t1ppnded Length : -. Compression Load' to 24 (610) 4,200 18.50 36 (914) 3,650 16.00 48 (1219) 3,130 13.50 60 (1524) 2,650 11.50 72 (1829) 2,230 9.50 84 (2134) 1,850 8.00 96 (2438) 1,570 6.50 108 (2743) 1,360 6.00 120 (3048) 1,200 5.00 'Note: i. Maximum axial load under seismic loading conditions. 2- The design bad shall not exceed the allowable loads for connection detall, ��'�,'% ✓"''dY �4ittt S� 22 �� ��yd+,Yh.44g!N': i wTN REVIEWED FOR CODE COMPLIANCE APPROVED OCT 12 2016 City of Tukwila BUILDING DIVISION' RECEIVED CITY OF TUKWILA OCT 04 2016 PERMIT CENTER Legal: THIS DRAWING AND THE DESIGN HEREIN ARE THE PROPERTY OF UNIVERSITY MECHANICAL CONTRACTORS, INC.. FOR THEIR USE IN CONSTRUCTION OF THIS PROJECT. NO OTHER USE SHALL BE PERMITTED. WITHOUT. THE WRITTEN CONSENT OF UNIVERSITY MECHANICAL CONTRACTORS, INC. <<<<<<< N Drawn By KH Checked By RK Original Issue Date 08/24/16 Job No. 6880 Scale AS SHOWN Sheet No. M1.03 1` © to Q V Z 00 o n Olt �'�' OD 0 Z 0) L_ L W -- O (9Q it 0 U)Q Q) 2W Q 1.11 Q F �W1� O p L_ 0) C0 c 0 O cfl O N rn r - M N 1 1 d' r- r� r7 cOMcD O O C14 V C 0 X ♦/mo/�w Vd LO Ci) Z rJ Cr. r - N +00 U) O0 _r � COV CO Z U Cr) O C Cr. 4C Fr. U) V W ~ Z CF)� �o Q ui O ca V 5 V g� Z3 E U ZD 7 Cie 3 3: I-- 3 N Drawn By KH Checked By RK Original Issue Date 08/24/16 Job No. 6880 Scale AS SHOWN Sheet No. M1.03 u - cn w � 0 L� a N s� U cD � N — H — — G _ __-. — g — — A — UP CORRIDOR 109 — A Q DEMO ALL CEILING HVAC SYSTEMS THAT SERVE THE SPACE SHOWN FIELD VERIFY ROUTING Q2 DEMO EXISTING EXHAUST DUCT SHOWN 18 19 20 21 I G { { E i t 1 y i S t 1 7 1 I t t i 110" L7 EAi' [10 , # Ey i - 1 [ # t t [ t tII C(1 Eli, 7 8 ( — D { tF B iF $- }— { t ! t r { # jj (/its 1 t # i e a 1 t 1 t - } ! 7 ! ; � I � i t - f }!""r'� t""YYtl ! f 7 1 t�tJ! 7 t ! t r� { {C � I�� �� FEC { ]jjj IC { -1 1,2 Cz f` C'Z C'T ♦ .I ♦� �4'♦� J J J J J J J 4, J j Fk J J - J J J J /' ell / ' ' J J ♦�I#S�SI AIB J J e ♦ e J J J e J � aee / ♦' J / / O J /' J ♦♦ /J''f ♦' /'!/' /' /♦ J'/J -JJ / ♦ ♦ /♦ ♦ / / / / / ♦J ♦ / ♦ / 0,♦ ♦ / J J J J ' J �J / J J J J J J J'J i i d ♦ e" ♦ ♦ ♦ / ♦ / .1♦'� / / / ,- ♦ / ♦ / ' J J J J J J J J ' ' ' ' ' ' ' J ♦I / ♦ ♦ ♦ / { —' r,>_=�T--r-T-s-T-r-r-s-7--s-�^-7--+^-T-"�^'-7---7-Y-�- J"�'�- r -T 1-7- l -T l T -T -T7 -T T-�T-T-T-T-T-r-T-T-7-T-T-T�7-T-7- 1-7- 1-7-T-7- 1-7- 1 -7 -7 -T7 -'T / ♦ ♦ ♦ ♦ I I ♦ / ♦ I ♦ / / I / ♦ / ♦ / i i : ♦ ♦ ♦ ♦ ♦ ♦ ♦ ♦ ♦ ♦ , ♦ ♦ ♦ ♦ / / / ♦ / ♦ ♦ ♦ ♦ ♦ ♦ ♦ / ♦ ♦ ♦ ♦ ♦ / ♦ / ♦ ♦ I ♦ ♦ ♦ ♦ ♦ ♦ ♦ ♦ / / / ♦ ♦ / ♦ ♦ ♦ ♦ / ♦ ♦ ♦ ♦ ♦ ♦ ♦ ♦ ♦ / ♦ ♦ / ♦ ♦ ♦ ♦ ♦ ♦ ♦ ♦ ♦ ♦ / / /J='7' �7J - /L-; - ,- , ;• i• J=`"' i yt� r :rte'-,"`—/�'' ;.'�—_....�.:_. �.._.__..-,.:.—,��.� -- ,'2,i `,`,i , , , , .`a fit J J J J J '-e J J J ; t J 1 I /E♦./ 'l' J J/6 J ' J ' J ' J%/� tl'�-°�'� �' J..���' ♦ �/ 'tJ ♦' r' �J ' J♦ Vis- �J J ,[{' (yp % J J J J J:,rt� -.ry�, J ,1��+ri�J ♦� !�'Jj j([♦J J' ♦/J♦/i y , J, �/— �O- �d-r J �Jt . iyJ J ' ' J ' i i J ' ' J ' J I # lU 1 � OF IJEY1! L� _�f 'i�4 ! f ! ! ! e J i' I ! /1 �.-,.Il�.s ./s 1 , # ♦ �tzr' J J t ♦i J J J J J J 1 ♦' n' I J J A J L/ ...r'i "i .t'i J i r' i� i i /i .� , ♦ ! ! ! ! ! /. " ! d i E /1 ! -♦' i CLOSE[ 108 { CPT �I FJ LEVEL 1 MECHANICAL DEMO PLAN SCALE: 1/4'= 1'-0' I CPT TO LATCHjj CPT t� I { REVIEW D FOR CODE COMPLIANCE APPROVED s; OCT 12 2016 BUILD .`'=" D1V4I# I— W 1— C tY W i C� Z `= 00 o .iILLM 4C o 00 0 x zrn o LL Uj C O vien cr �i Q N O p LL! \ LU Q W !— o = LU tW c n a - O O (0 O N 0) M N f'7 M co co O O N N w [ '� N V C z O x CO) � _ N 00rnrn LLJ V+ z 4' m W O O U Za � Lu = p m I At E � /1 U J E 1, J LU J —G)I- E I RECEIVED CITY OF TUKWILA OCT 04 2016 PERMIT CENTER Legal: THIS DRAWING AND THE DESIGN HEREIN ARE THE PROPERTY OF UNIVERSITY MECHANICAL CONTRACTORS, INC. FOR THEIR USE IN CONSTRUCTION OF THIS PROJECT. NO- OTHER USE SHALL BE PERMITTED WITHOUT THE WRITTEN CONSENT OF UNIVERSITY MECHANICAL CONTRACTORS, INC. V. A wASy�O�� c� v �'��ONA�- '- 09/26/2m16 Drawn By KH Checked By RK Original Issue Date 08/24/16 Job No. 6880 Scale AS SHOWN Sheet No. MD2.01 17 I I I I I I { I — A — UP CORRIDOR 109 — A Q DEMO ALL CEILING HVAC SYSTEMS THAT SERVE THE SPACE SHOWN FIELD VERIFY ROUTING Q2 DEMO EXISTING EXHAUST DUCT SHOWN 18 19 20 21 I G { { E i t 1 y i S t 1 7 1 I t t i 110" L7 EAi' [10 , # Ey i - 1 [ # t t [ t tII C(1 Eli, 7 8 ( — D { tF B iF $- }— { t ! t r { # jj (/its 1 t # i e a 1 t 1 t - } ! 7 ! ; � I � i t - f }!""r'� t""YYtl ! f 7 1 t�tJ! 7 t ! t r� { {C � I�� �� FEC { ]jjj IC { -1 1,2 Cz f` C'Z C'T ♦ .I ♦� �4'♦� J J J J J J J 4, J j Fk J J - J J J J /' ell / ' ' J J ♦�I#S�SI AIB J J e ♦ e J J J e J � aee / ♦' J / / O J /' J ♦♦ /J''f ♦' /'!/' /' /♦ J'/J -JJ / ♦ ♦ /♦ ♦ / / / / / ♦J ♦ / ♦ / 0,♦ ♦ / J J J J ' J �J / J J J J J J J'J i i d ♦ e" ♦ ♦ ♦ / ♦ / .1♦'� / / / ,- ♦ / ♦ / ' J J J J J J J J ' ' ' ' ' ' ' J ♦I / ♦ ♦ ♦ / { —' r,>_=�T--r-T-s-T-r-r-s-7--s-�^-7--+^-T-"�^'-7---7-Y-�- J"�'�- r -T 1-7- l -T l T -T -T7 -T T-�T-T-T-T-T-r-T-T-7-T-T-T�7-T-7- 1-7- 1-7-T-7- 1-7- 1 -7 -7 -T7 -'T / ♦ ♦ ♦ ♦ I I ♦ / ♦ I ♦ / / I / ♦ / ♦ / i i : ♦ ♦ ♦ ♦ ♦ ♦ ♦ ♦ ♦ ♦ , ♦ ♦ ♦ ♦ / / / ♦ / ♦ ♦ ♦ ♦ ♦ ♦ ♦ / ♦ ♦ ♦ ♦ ♦ / ♦ / ♦ ♦ I ♦ ♦ ♦ ♦ ♦ ♦ ♦ ♦ / / / ♦ ♦ / ♦ ♦ ♦ ♦ / ♦ ♦ ♦ ♦ ♦ ♦ ♦ ♦ ♦ / ♦ ♦ / ♦ ♦ ♦ ♦ ♦ ♦ ♦ ♦ ♦ ♦ / / /J='7' �7J - /L-; - ,- , ;• i• J=`"' i yt� r :rte'-,"`—/�'' ;.'�—_....�.:_. �.._.__..-,.:.—,��.� -- ,'2,i `,`,i , , , , .`a fit J J J J J '-e J J J ; t J 1 I /E♦./ 'l' J J/6 J ' J ' J ' J%/� tl'�-°�'� �' J..���' ♦ �/ 'tJ ♦' r' �J ' J♦ Vis- �J J ,[{' (yp % J J J J J:,rt� -.ry�, J ,1��+ri�J ♦� !�'Jj j([♦J J' ♦/J♦/i y , J, �/— �O- �d-r J �Jt . iyJ J ' ' J ' i i J ' ' J ' J I # lU 1 � OF IJEY1! L� _�f 'i�4 ! f ! ! ! e J i' I ! /1 �.-,.Il�.s ./s 1 , # ♦ �tzr' J J t ♦i J J J J J J 1 ♦' n' I J J A J L/ ...r'i "i .t'i J i r' i� i i /i .� , ♦ ! ! ! ! ! /. " ! d i E /1 ! -♦' i CLOSE[ 108 { CPT �I FJ LEVEL 1 MECHANICAL DEMO PLAN SCALE: 1/4'= 1'-0' I CPT TO LATCHjj CPT t� I { REVIEW D FOR CODE COMPLIANCE APPROVED s; OCT 12 2016 BUILD .`'=" D1V4I# I— W 1— C tY W i C� Z `= 00 o .iILLM 4C o 00 0 x zrn o LL Uj C O vien cr �i Q N O p LL! \ LU Q W !— o = LU tW c n a - O O (0 O N 0) M N f'7 M co co O O N N w [ '� N V C z O x CO) � _ N 00rnrn LLJ V+ z 4' m W O O U Za � Lu = p m I At E � /1 U J E 1, J LU J —G)I- E I RECEIVED CITY OF TUKWILA OCT 04 2016 PERMIT CENTER Legal: THIS DRAWING AND THE DESIGN HEREIN ARE THE PROPERTY OF UNIVERSITY MECHANICAL CONTRACTORS, INC. FOR THEIR USE IN CONSTRUCTION OF THIS PROJECT. NO- OTHER USE SHALL BE PERMITTED WITHOUT THE WRITTEN CONSENT OF UNIVERSITY MECHANICAL CONTRACTORS, INC. V. A wASy�O�� c� v �'��ONA�- '- 09/26/2m16 Drawn By KH Checked By RK Original Issue Date 08/24/16 Job No. 6880 Scale AS SHOWN Sheet No. MD2.01 Eel 1 LEVEL 2 MECHANICAL DEMO PLAN SCALE: 1/4' = 1'-0' REVIEWED FOR CODE COMPLIANCE APPROVED OCT 12 2016 I` I City of Tukwila BUILDING DIVISION., O i RECEIVED CITY OF TUKWILA OCT 042016 PERMIT CENTER Legal: THIS DRAWING AND THE DESIGN HEREIN ARE THE PROPERTY OF UNIVERSITY MECHANICAL CONTRACTORS, INC. FOR THEIR USE IN CONSTRUCTION OF THIS PROJECT. NO OTHER USE SHALL BE PERMITTED WITHOUT THE WRITTEN CONSENT OF UNIVERSITY MECHANICAL CONTRACTORS, INC. O �) O N � � N 1 C, O (3 v) N W G CC W C_ iv zi aaaaaaa O ¢ ' Z W �� o. va J LL. T 00 LL o W O ¢ �S ui � 0 WUj � ~ Q 0 _ LU O 0 iii 3 d a- O O (D O N a) 0) N to to M r7 O O C14 Z O X CL L? < {i `AW _r Lr) O Jr- N �� U Q7 � C Q Uv1 J Cr.� � 4 v_c_ U) t. � uiLIJ E O U E J LLJ 3 WNEW N �O of WASy,� A 5 d0 �0� FFG/ST ERF'O �SS�D NAI- EAG @9/26/2016 Drawn By KH Checked By RK Original Issue Date 08/24/16 Job No. 6880 Scale AS SHOWN Sheet No. MD2,02 w c a cJ f. cc Li V. -s- C Q; L CD O G° i as C w 'Kf Ln Vi LJ co 0 C5 LL f33 16 17 18 19 20 21 I � I I ► ( 8 i e - i I f I � I • I I I tI I I I I I l I l I I CV 1 a E a I I N 18X1 0 _ s EXHA U 1W9 U I—' W N L U i G W I FEF - L O r Vi � 0 z 00 O O E i I 18) !` L U Z O Q - M O (R Q a)W L w c 0 Uj Q F Q W 0 L O az I � I I 0000 i � I I 0 0 0 C) .v LEVEL 1 MECHANICAL PLAN 1 SCALE: 1/4' = 1'-0' a o N. C3 `� L � DRAWING NOTES: 01 CONNECT NEW EXHAUST DUCTWORK TO EXISTING EXHAUST LOUVER PLENUM 02 24X24 MAKEUP AIR LOUVER THROUGH RESTROOM DOOR PROVIDED BY OTHERS 3� MAKEUP AIR LOUVER MOUNTED IN WALL ABOVE DOOR BELOW CEILING AND DUCT ROUTED INTO SPACE AND DOWN TO CEILING GRILL IN RESTROOM SPACE REVIEWED FOR CODE COMPLIANCE APPROVED r OCT 12 2016 I City d TukWtla BUILDING DIVISION PERMIT CENTER Legal: THIS DRAWING AND THE DESIGN HEREIN ARE THE PROPERTY OF UNIVERSITY MECHANICAL CONTRACTORS, INC. FOR THEIR USE IN CONSTRUCTION OF THIS PROJECT. NO OTHER USE SHALL BE PERMITTED WITHOUT THE WRITTEN CONSENT OF UNIVERSITY MECHANICAL CONTRACTORS, INC. 1 o N I N 0 U U U I—' W N L W L O r Vi � 0 z 00 O O !` L U Z Q - M O (R Q a)W w 0 Uj Q F Q W 0 L a_ d O (O O N O) r- � N CSO Cfl M M Coco O O C14 ■ c O j< tel° C Lr) 0 N _ (� V C O / � /CO) �� Zv c . C Uj > V LL J L .o U !� U w 3 W J N OPS V � �O of Was e co v Q 5 40 /O NA t EAG 09/2612016 Drawn By KH Checked By RK Original Issue Date 08/24/16 Job No. 6880 Scale AS SHOWN Sheet No. M2.01 I Q e- U) CONTROLS SEQUENCE: O AIR HANDLING UNIT RESTROOM EXHAUST SEQUENCE OF OPERATION A. OPERATION A. OPERATION 1 THE INDOOR FAN COIL UNIT SHALL BE FURNISHED WITH A COMPLETE, FACTORY- 1 THE FAN PROVIDES EXHAUST FOR THE NEW SPACE RESTROOMS TO CONTROL THE SPREAD OF ODORS. INSTALLED, DDC CONTROL SYSTEM BASED ON AN OPEN PROTOCOL MATCHING BUILDING'S EXISTING PROTOCOL 2 THE FAN IS INTENDED TO OPERATE WHILE BUILDING IS OCCUPIED 2 THE UNIT IS TO BE FURNISHED COMPLETE WITH COOLING COIL, HEATING COIL, OSA MIXING BOX_ B. OCCUPIED MODE W/ ASSOCIATED DAMPER ACTUATORS, VARIABLE VOLUME SUPPLY FAN WITH VFD, AND FILTERS. 1 FAN START/STOP: ON COMMAND FROM THE BMS, SYSTEM STARTUP SEQUENCE SHALL BE INITIATED. THE FAN SHALL START 3 MICROPROCESSOR -BASED CONTROLS SHALL BE PROGRAMMED AT THE MANUFACTURER'S FACTORY. 2 THE EXHAUST FAN SHALL BE BALANCED TO MATCH OSA DAMPERS AND PROVIDE A NUTRAL SYSTEM PRESSURIZATION. INCLUDE PROGRAMS FOR VARIABLE VOLUME OPERATION FOR SUPPLY FANS C. UNOCCUPIED MODE VIA VARIABLE SPEED DRIVES, DRY BULB ECONOMIZER OPERATION, BUILDING PRESSURE CONTROL, 1 THE RESTROOM EXHAUST FAN IS INTENDED TO OPERATE WHILE BUILDING IS OCCUPIED. IF AHU IS RUNNING THIS EXHAUST FAN SHALL RUN DEMAND CONTROL VENTILATION, AND DISCHARGE AIR RESET BASED ON OUTDOOR AIR TEMPERATURE, D. ARE ALARM OCCUPIED/UNOCCUPIED CONTROL WITH MORNING WARM-UP OPTIMAL START SEQUENCE. 1 ON RECEIPT OF AFIRE ALARM SIGNAL THE EXHAUST FAN SHALL. STOP B. OCCUPIED MODE 1 UPON INITIATION OF THE OCCUPIED CYCLE AS DETERMINED BY THE BUILDING AUTOMATION SYSTEM, THE MANUFACTURER'S MICROPROCESSOR CONTROL SYSTEM SHALL ENABLE THE OCCUPIED CONTROL SEQUENCE. 2 WARMUP: MORNING WARMUP START SHALL BE CALCULATED BY THE MANUFACTURER'S OPTIMAL START Q PROGRAM. THE INTERNAL CONTROLS SHALL START THE SUPPLY FAN WITH ALL DAMPERS IN THE RECIRCULATION MODE. MORNING WARMUP SHALL CONTINUE UNTIL RETURN AIR TEMPERATURE REACHES HEATING SETPOINT. PLEASE NOTE THERE IS NO HEAT IN THE UNIT. 3 OCCUPIED MODE: ON COMPLETION OF THE WARMUP CYCLE, THE VENTILATION DAMPER SHALL OPEN TO U) MINIMUM POSITION. WHEN EQUIPPED WITH AN OSA MEASUREMENT STATION, THE OUTSIDE AIR DAMPER SHALL MODULATE TO MAINTAIN VENTILATION AIR SETPOINT. ECONOMIZER 0 MODULE CONTROLS SHALL SEQUENCE TO MAINTAIN DISCHARGE AIR SETPOINT. 4 SUPPLY FAN CONTROL: SUPPLY AIRFLOW SHALL BE CONTROLLED BY A DUCT STATIC PRESSURE SENSOR LU ¢ WHICH SHALL MODULATE THE SUPPLY FAN VARIABLE FREQUENCY DRIVE TO MAINTAIN SETPOINT. 7 ARE ALARM SIGNAL ON RECEIPT OF AFIRE ALARM FROM THE DIVISION 16 CONTRACTOR'S SYSTEM, THE V,r W BUILDING AUTOMATION SYSTEM SHALL STOP THE AIR HANDLING UNIT. C. UNOCCUPIED MODE 1 IN UNOCCUPIED MODE, AS ESTABLISHED BY THE BUILDING AUTOMATION SYSTEM OR MANUFACTURER'S INTEGRAL CONTROL PANEL, THE AIR HANDLING UNIT SHALL BE OFF WITH DAMPERS IN 100% RETURN AIR a POSITION. o — m — — B _ _ _ 3 __ ____ I 22x16 MPS — h — — A _ _— A _ —__ — , DRAWING NOTES: 01 OSA EXTERIOR LOUVER, LOUVER SIZE AND LOCATION TO BE COORDINATE WITH GC BASED ON EXTERIOR TILING. LOUVER SHALL HAVE GREATER THAN 50% FREE AREA AND INLET SHALL BE PROTECTED AGAINST LOCAL WEATHER CONDITIONS. 1 LEVEL 2 MECHANICAL PLAN SCALE: 1/4' = 1'-0' REVIEWED FOR CODE COMPLIANCE j = APPROVED A ..j. OCT 12 2016 City of Tukwila BUILDING DIVISION RECEIVED I CITY OF TUKWILA OCT 0 4 2016 PERMIT CENTER Legal:. THIS DRAWING AND THE DESIGN HEREIN ARE THE PROPERTY OF UNIVERSITY MECHANICAL CONTRACTORS, INC. FOR THEIR USE IN CONSTRUCTION OF THIS PROJECT. NO OTHER USE SHALL BE PERMITTED WITHOUT THE WRITTEN CONSENT OF UNIVERSITY MECHANICAL CONTRACTORS, INC. I -- w tn I— >j CL E1 ziaaaaaaa V. 9PoF WAS �O !�`�. 't GIST EF SS�O NA 1. Drawn By KH Checked By RK Original Issue Date 08/24/1.6 Job No. 6880 Scale AS SHOWN Sheet No. M2.02 O v/ Z ♦Vw/ 0 Z Q CD 0 4C T CO 0 0) Q c U) M LLj 3 0 W0 H LU ¢ 4- V,r W Q Q o 0 °- a o C) co O N 0)� of N I I �t c0 co r7 r� 0 C4 C4� z O 0 = X IL U .. J N 00+ J V 0 f2 a) v c J z d9r Im 4C '�-C— LU = H 0') U >oz � o z LU =' m V cp U LU E 0 CN LU 3 1.0 J N V. 9PoF WAS �O !�`�. 't GIST EF SS�O NA 1. Drawn By KH Checked By RK Original Issue Date 08/24/1.6 Job No. 6880 Scale AS SHOWN Sheet No. M2.02 � I ! ! o co Do W ! I LA � co up N O1 FIELD FABRICATE UNIT HANGING SYSTEM BASED ON STRUCTURAL CALCULATIONS AND SEISMIC REQUIREMENTS, REF STRUCTURAL SEE DRAWING M1.02 22 LEVEL 2 MECHANICAL PIPING PLAN 1 SCALE: 1/4' = 1'-0' 101 OWN � RECEIVED CITY OF TUKWILA N OCT 0 4 2016 PERMIT CENTER REVIEWED FOR CODE COMPLIANCE APPROVED Legal: THIS DRAWING AND THE DESIGN OCT 12 2016 UN VEIRSITY MECHANICALARE THE OF CONTRACTORS, INC. FOR THEIR City Of Tukwila BUILDING DIVISION USE IN CONSTRUCTION OF THIS PROJECT. NO OTHER USE SHALL BE PERMITTED WITHOUT THE WRITTEN CONSENT OF UNIVERSITY MECHANICAL CONTRACTORS, INC. � of N o � N ONO U co N N I—' W t!1 L W z co z �o 0 j r 0i 5= L. LL W Q O 0 S c 0 � Cf) Q �W oUj LU Q � = d' W o n W ( 2 �� c o o co C) N C r- 0') N � cp CDMCD 0 0 CN. ■ N C Z/ V ■■,� O X Q i c>_ ■` V J � >- �C © � N � °° CL --C■� °'� < Z � LIJ 0.E - U = � o Z Z W m e .Q! /O� cp LL1 L E O V N E Lu LLI 3 a� i= PL V �O °E wAsy�O�� Q c0 v ,p 5 40' FFG/ST6RF"O \��v S/O NA %-ENG 09/26/2016 Drawn By KH Checked By RK Original Issue Date 08/24/16 Job No. 6880 Scale AS SHOWN Sheet No. MP2.02