HomeMy WebLinkAboutPermit M16-0170 - EXTENDED STAY AMERICA - DUCTLESS SPLIT SYSTEM HEAT PUMPEXTENDED STAY AMERICA
15635 W VALLEY HVVY
M16-0170
City of Tukwila
Department of Community Development
• 6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206-431-3670
Inspection Request Line: 206-438-9350
Web site: http://www.TukwilaWA.gov
MECHANICAL PERMIT
Parcel No: 0005800015 Permit Number: M16-0170
Address: 15635 W VALLEY HWY Issue Date: 11/17/2016
Permit Expires On: 5/16/2017
Project Name: EXTENDED STAY AMERICA
Owner:
Name: EXTENDED STAY HOTELS
Address: PO BOX 49550 ATTN PROPERTY TAX,
Phone: (206) 396-5528
Phone: (206) 860-3832
Expiration Date: 6/16/2018
Address: "I
,
DESCRIPTION OF WORK:
PROVIDE AND INSTALL (1) 1 TON DUCTLESS SPLIT SYSTEM HEAT PUMP FOR THE ELEVATOR MACHINE ROOM
Valuation of Work: $8,000.00
Type of Work: NEW
Fuel type: ELECT
Fees Collected: $298.16
Electrical Service Provided by: PUGEST SOUND ENERGY
Water District: TUKWILA
Sewer District: TUKWILA
Current Codes adopted by the City of Tukwila:
International Building Code Edition: 2015 National Electrical Code: 2014
International Residential Code Edition: 2015 WA Cities Electrical Code: 2014
International Mechanical Code Edition: 2015 WAC 296-46B: 2014
Uniform Plumbing Code Edition: 2015 WA State Energy Code: 2015
International Fuel Gas Code: 2015
Permit Center Authorized Signature: Date: 1,
CHARLOTTE, WA, 28277
Contact Person:
Name:
MONTE LONG
Address:
136201ST AVE S, BURIEN, WA, 98168
Contractor:
Name:
WASHINGTON HEATING & A/C INC
Address:
13620 FIRST AVE S , SEATTLE, WA,
98114
License No:
WASHIHAO12LQ
Lender:
Name:
Phone: (206) 396-5528
Phone: (206) 860-3832
Expiration Date: 6/16/2018
Address: "I
,
DESCRIPTION OF WORK:
PROVIDE AND INSTALL (1) 1 TON DUCTLESS SPLIT SYSTEM HEAT PUMP FOR THE ELEVATOR MACHINE ROOM
Valuation of Work: $8,000.00
Type of Work: NEW
Fuel type: ELECT
Fees Collected: $298.16
Electrical Service Provided by: PUGEST SOUND ENERGY
Water District: TUKWILA
Sewer District: TUKWILA
Current Codes adopted by the City of Tukwila:
International Building Code Edition: 2015 National Electrical Code: 2014
International Residential Code Edition: 2015 WA Cities Electrical Code: 2014
International Mechanical Code Edition: 2015 WAC 296-46B: 2014
Uniform Plumbing Code Edition: 2015 WA State Energy Code: 2015
International Fuel Gas Code: 2015
Permit Center Authorized Signature: Date: 1,
I hearby certify that I have read and examined this permit and know the same to be true and correct. All
provisions of law and ordinances governing this work will be complied with, whether specified herein or not.
The granting of this permit does not presume to give authority to violate or cancel the provisions of any other
state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this
development permit and agree to the conditions attached to this permit.
Signature: �� s Date:
Print Name: M ON 1LiJ�,
This permit shall become null and void if the work is not commenced within 180 days for the date of issuance, or if
the work is suspended or abandoned for a period of 180 days from the last inspection.
PERMIT CONDITIONS:
1: Work shall be installed in accordance with the approved construction documents, and any changes made
during construction that are not in accordance with the approved construction documents shall be
resubmitted for approval.
2: All permits, inspection record card and approved construction documents shall be kept at the site of work
and shall be open to inspection by the Building Inspector until final inspection approval is granted.
3: All construction shall be done in conformance with the Washington State Building Code and the
Washington State Energy Code.
4: Remove all demolition rubble and loose miscellaneous material from lot or parcel of ground, properly cap
the sanitary sewer connections, and properly fill or otherwise protect all basements, cellars, septic tanks,
wells, and other excavations. Final inspection approval will be determined by the building inspector based
on satisfactory completion of this requirement.
5: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the
City of Tukwila Building Department (206-431-3670).
6: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila
Permit Center.
7: ***MECHANICAL PERMIT CONDITIONS***
8: All mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila
Permit Center (206/431-3670).
9: Manufacturers installation instructions shall be available on the job site at the time of inspection.
PERMIT INSPECTIONS REQUIRED
Permit Inspection Line: (206) 438-9350
0703
MECH EQUIP EFF
1800
MECHANICAL FINAL
0705
REFRIGERATION EQUIP
0701
ROUGH -IN MECHANICAL
CITY OF TUKW.
Community Development Department
Permit Center
• 6300 Southcenter Blvd., Suite 100
Tukwila, WA 98188
http://www.TukwilaWA.gov
SITE LOCATION
Mechanical Permit No.
Project No.
Date Application Accepted:
Date Application Expires:
use
MECHANICAL PERMIT APPLICATION
Applications and plans must be complete in order to be accepted for plan review.
Applications will not be accepted through the mail or by fax.
**please print**
King Co Assessor's Tax No.. 000580015
Site Address: 15635 W Valley Hwy Suite Number: Floor:
Tenant Name: Extended Stay America New Tenant: ❑ .....Yes ®..No
PROPERTY OWNER
Name:
Address:
City: State: Zip:
CONTACT PERSON — person receiving all project
communication
Name: Monte Long
Address: 13620 1st Ave. South
City: Burien State: WA Zip: 98168
Phone: (206) 396-5528 Fax: (206) 860-3832
Email: mrlong@washingtonheating.com
Valuation of project (contractor's bid price): $ 8,000
Describe the scope of work in detail:
MECHANICAL CONTRACTOR INFORMATION
Company Name: Washington Heating & A/C Inc.
Address. 13620 1st Ave. South
City: Burien State: WA Zip: 98168
Phone: (206) 860-3832 Fax: (206) 860-3799
Contr Reg No.: WASHIHAO12LQ Exp Date: 06/16/2017
Tukwila Business License No.: BUS -0996522
Provide and install (1) 1 ton ductless split system heat pump for the elevator machine room.
Use: Residential:
New
.......... ❑
Replacement ........
❑
Commercial:
New
.......... 1z
Replacement ........
❑
Fuel Type: Electric.....
LZ
Gas .......
❑ Other:
H:Wpplications\Porms-Applications On Line\2016 ApplicationsWechanical Permit Application Revised 14-16.docz
Revised: January 2016 Page 1 of 2
bh
Indicate type of mechanical work being installed and the quantity below:
Unit Type
Qty
Furnace <100k btu
Residential, Nighttime
Furnace >100k btu
Industrial
Floor furnace
55 dB(A)
Suspended/wall/floor
mounted heater
57 dB(A)
Appliance vent
Commercial
Repair or addition to
heat/refrig/cooling
system
1
Air handling unit
<10,000 cfm
65 dB(A)
Unit Type
Qty
Air handling unit
>10,000 cfm
Residential, Nighttime
Evaporator cooler
Industrial
Ventilation fan
connected to single duct
55 dB(A)
Ventilation system
57 dB(A)
Hood and duct
Commercial
Incinerator — domestic
1
Incinerator —
comm/industrial
65 dB(A)
Unit Type
Qty %..
Fire damper
Residential, Nighttime
Diffuser
Industrial
Thermostat
55 dB(A)
Wood/gas stove
57 dB(A)
Emergency enerator
Commercial
Other mechanical
equipment
1
60 dB(A)
65 dB(A)
Boiler/Compressor Qty
0-3 hp/100,000 btu
3-15 h /500,000 btu
15-30 hp/1,000,000 btu
30-50 hp/1,750,000 btu
50+ h /1,750,000 btu
Noise:
Mechanical units need to be in compliance with the Tukwila Noise Code. Maximum permissible sound levels are based on from where the sound is
created and where the sound is heard. Additionally, if sound can be heard from within a house at night in a residential zone it may not be allowed.
For more details, see TMC 8.22
District of Sound
Producing Source
District of Receiving Property
Residential, Daytime*
Residential, Nighttime
Commercial
Industrial
Residential
55 dB(A)
45 dB(A)
57 dB(A)
60 dB(A)
Commercial
57 dB(A)
47 dB(A)
60 dB(A)
65 dB(A)
Industrial
60 dB(A)
50 dB(A)
65 dB(A)
70 dB(A)
*Daytime means 7AM-IOPM, Monday through Friday and 8AM-IOPM, Saturday, Sunday and State -recognized holidays.
A few sounds are exempt from the noise code, including:
Warning devices;
Construction and property maintenance during the daytime hours (lam-IOpm);
Testing of backup generators during the day.
PERMIT APPLICATION NOTES
Value of construction — in all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject
to possible revision by the permit center to comply with current fee schedules.
Expiration of plan review — applications for which no permit is issued within 180 days following the date of application shall expire by limitation.
The building official may grant one extension of time for additional periods not to exceed 90 days each. The extension shall be requested in writing
and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition).
I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER
PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT.
BUILDING OWNER OR AUTHORIZED AGENT:
Signature: �� — Date: 11/03/2016
Print Name: Monte Long Day Telephone: (206) 860-3832
Mailing Address: 13620 1 St. Ave. South Burien WA 98168
City State Zip
H:Wpplications\Forms-Applications On Line\2016 Applications\Mechanical Permit Application Revised 14-16.docx
Revised: January 2016 Page 2 of 2
bh
DESCRIPTIONS
PermitTRAK
ACCOUNTQUANTITY
PAID
$298.16
M16-0170 Address: 15635 W VALLEY HWY
Apn: 0005800015
$298.16
MECHANICAL
$286.69
PERMIT ISSUANCE BASE FEE
R000.322.100.00.00
0.00
$32.50
PERMIT FEE
R000.322.100.00.00
0.00
$196.85
PLAN CHECK FEE
R000.322.102.00.00
0.00
$57.34
TECHNOLOGY FEE
$11.47
TECHNOLOGY FEE
TOTAL FEES PAID • • : 1 1
R000.322.900.04.00
0.00
$11.47
Date Paid: Thursday, November 03, 2016
Paid By: MONTHEA LONG
Pay Method: CREDIT CARD 01856G
Printed: Thursday, November 03, 2016 3:52 PM 1 of 1 R
SYSTEMS
INSPECTION RECORD
Retain a copy with permit 104 I
INSPECTION NO. PERMIT NO.
CITY OF TUKWILA BUILDING DIVISION
6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206)431 _161
Permit Inspection Request Line (206) 438-9350
Project:
Type of Inspection:
&ibeb S
9(A1- C—JA121L
Address:
Erate Called:
Special Instructions:
Date Want
P.
lRequesto1r:
Phone No:
Approved per applicable codes. Corrections required prior to approval.
Inspector: Date: '012 Al I
U REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be
paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection.
INSPECTION RECORD 170
Retain a copy with permitY11 70
INSPECTION N0, PERMIT NO.
CITY OE TUKWILA BUILDING DIVISION
6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670
Permit Inspection Request Line (206) 438-9350
Project:
FX S cv6(-Q-
Type of Inspection:
nAL
Address:
IANAZtey AzAH
Date Called:
Special Instructions:
Date 'anti/ a.m.
(P
Request r:
Phone No:
Approved per applicable codes. (M Corrections required prior to approval.
I paid at 6300 Southcenter Blvd., Suite 100. Call, to schedule reinspection.
PERMIT C00R6 COPY,
PLAN REVIEW/ROUTING SLIP
PERMIT NUMBER: M16-0170
DATE: 11/03/16
PROJECT NAME: EXTENDED STAY AMERICA
SITE ADDRESS: 15635 W VALLEY HWY
X Original Plan Submittal Revision # before Permit Issued
Response to Correction Letter #
DEPARTMENTS:
T AWC
Building Division
Revision # after Permit Issued
MA A//✓�'
Fire Prevention
Planning Division ❑
Public Works ❑ Structural ❑ Permit Coordinator
PRELIMINARY REVIEW: DATE: 11/08/16
Not Applicable ❑ Structural Review Required ❑
(no approval/review required)
REVIEWER'S INITIALS:
DATE:
APPROVALS OR CORRECTIONS: DUE DATE: 12/06/16
Approved ❑ Approved with Conditions 9
Corrections Required ❑
(corrections entered in Reviews)
Notation:
REVIEWER'S INITIALS:
Denied ❑
(ie: Zoning Issues)
DATE:
Permit Center Use Only
CORRECTION LETTER MAILED:
Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials:
12/18/2013
WASHINGTON HEATING & AIC TNC
Home Fspahol Contact
Page I of 2
Search L&h --I
A -Z Index Help My L&I
Safety & Health Claims & Insurance Workplace Rights Trades & Licensing
45 Washington State Department of
Labor & Industries
WASHINGTON HEATING & A/C INC
Owner or tradesperson
13620 FIRST AVE S
Developers Surety & Indem Co
SEATTLE, WA 98168
Principals
206-860-3832
TRAN, STEVEN c, PRESIDENT
KING County
LONG, MONTHEA R, VICE PRESIDENT
Effective date
PECH, MAKARA, SECRETARY
06/16/2011
(End: 05/30/2008)
Expiration date
LONG, MAKARA, PRESIDENT
Until Canceled
(End: 06/17/2008)
Doing business as
WASHINGTON HEATING & A/C INC
WA UBI No. Business type
601 962 099 Corporation
Governing persons
MONTHEA
R
LONG
STEVEN TRAN;
License
Verify the contractor's active registration / license / certification (depending on trade) and any past violations.
Construction Contractor Active.
..........................................................
Meets current requirements.
License specialties
Heating/Vent/Air-Conditioning and Refrig
(HVAC/R)
License no.
WASHIHAO12LO
Effective — expiration
06118/1999— 06/16/2018
Bond
Developers Surety & Indem Co
$6,000.00
Bond account no.
252216C
Received by L&I
Effective date
05/25/2011
06/16/2011
Expiration date
Until Canceled
Bond history
Ira
..nsu............nce........
Ohio Security Ins Co $1,000,000.00
Policy no.
BKS53513733
Received by L&I Effective date
05/12/2016 06/16/2011
https:Hsecure.Ini.wa.gov/verify/Detail.aspx?UBI=601962099&LIC=WASHIHAO 12LQ&SAW=
Help us improve
11/14/2016
FA
SITE PLAN
wrs
OHP -1
CEILING
FC -1
ELEVAT
F-1II Rao IN DIDg,
HVAC ELEVATION PIAN
SCALE: 1/4" = 1'-0"
EQUIPMENT
SCHEDULE
TAG:
OHP -1
MAKE
DAIKIN
MODEL:
RX12NMVJU
COOLING:
12,000 BTU/H
ELECT:
208V 1PH AMP=15
SEERi
19 SEER
SOUND:
45dBA
WEIGHT:
60 LBS
CFM:
THE WRITTEN APPROVAL OF WASHINGTON
PROJECT DATA:
EXTENDED STAY AMERICA
15635 W. VALLEY HWY
TUKWILA, WA 98188
PARCEL # 0005800015
FC -1
DAIKIN
FTX12NMVJU
12,000 BTU/H
208 V 1PH MCA=1
00 L -BS
380
SCOPE OF WORK:
INSTALL (1) 1 TON DUCTLESS SPLIT HEAT
PUMP TO SERVE THE ELEVATOR MACHINE
ROOM.
LEGAL DESCRIPTION
MEADER HENRY -D C #46 COMM INTSN OF MONUMENT LN OF
SECONDARY ST HWY 2M, WEST VALLEY HWY, BEING 72 FT
WLY, MEAS AT R/A TO ELY MGN WITH MONUMENT LN OF S
158TH ST BEING 28 FT S OF AS MEAS AT R/A TO NLY R/W
LN SD INTSN BEING REPRESENTED BY A PUNCHED R/R SPIKE
TH N 07-41-30 W ALG MONUMENT LN SD SECONDARY HWY 2M
DIST 261.51 FT TH S 85-21-00 W 78.11 FT TO WLY R/W LN
& TPOB TH N 07-41-30 W 24839 FT TH N 88-04-26 W 170
FT M/L TO ELY LN OF ORDINARY HIGH WATER OF GREEN RIVER
AS EXISTED PRIOR TO C/L CHANNEL CHANGE OF GREEN RIVER
AS SHOWN ON SR 405 GREEN RIVER INTERCHANGE STA99+00
TO STA 120+00 APPROVED 1-30-62 TH SWLY ALG SD ELY LN
TAP FR WCH TPOB BEARS S 85-21-00 W FR SD PT TH N 85-21-00
E 440 FT M/L TO TPOB
z
ELEVATOR
MACHINE
RSM 9'X7'
FC -1
CONDENSATE PUMP
TO EXTERIOR
STAIR
f': r(&ED FOR:
Q N13, Chanical
Lfd
Electrical
dumbing
F' Uas Piping
of Tukwila
DIVISION
REFRIG, LINE
TO HP -1
L-hington
eating
. and
IP
conditioning
INC
Washington Heating
and AC, inc
13620 1 st Avenue South
Burien, Washington 98168
ph: (206) 860-3832 fax: (206) 860-3799
Contractor's License No.: WASHIHAO12LQ
www.washingtonheating.com
STAMP
No changes shalt be ma a to the scope
of work without prior pproval of
Tukwila Building !vision.
NUTS: Revisions vat require a ew plan submitt
and may include additional M Ma,
Plan review ,ppro+ I is subject to errors and omissions.
Approval of consi:r °lion documents does not autho iza
the violation of any dopted code or ordinance. Reccipt
of approved Field Q PY and conditions is acknowledged:
By:
Date:_ ir(h11f_
Of Tukwila,
Q DIVISION
REVIEWED FOR
ODE. COMPLIANCE
APPROVED
NOV 0 9 2016
AXT 9
City of Tukwi(a.
BUILDING DIViSION
RECEIVED
CITY OF TU KWILA
NOV 03 2016
PERMIT CENTER
OHP -1
HVAC,
FLD❑R PLAN
SCALE: 1/4" 1'-0"
ME -3100
DRAWING 17XES
HVAC FLOOR PLAN
{
"KIN
J
PROJECT MANAGER
DESIGNED BY
ML
ST
DRAWN BY
CHECKED BY
ST
Sr
SCALE
PROJECT NO.
AS NOTM
201M
THIS DRAWING IS THE SOLE PROPERTY OF WASHINGTON
HEATING & AIR CONDMONG, INC.
ANY REPRODUCTION,
DUPLICATION, ADDITIONS AND/OR
MODIFICATIONS REQUIRE
THE WRITTEN APPROVAL OF WASHINGTON
HEATING & AIR
CONDITIONING, INC.
SHEET NUMBER
AC 04
FA
SITE PLAN
wrs
OHP -1
CEILING
FC -1
ELEVAT
F-1II Rao IN DIDg,
HVAC ELEVATION PIAN
SCALE: 1/4" = 1'-0"
EQUIPMENT
SCHEDULE
TAG:
OHP -1
MAKE
DAIKIN
MODEL:
RX12NMVJU
COOLING:
12,000 BTU/H
ELECT:
208V 1PH AMP=15
SEERi
19 SEER
SOUND:
45dBA
WEIGHT:
60 LBS
CFM:
THE WRITTEN APPROVAL OF WASHINGTON
PROJECT DATA:
EXTENDED STAY AMERICA
15635 W. VALLEY HWY
TUKWILA, WA 98188
PARCEL # 0005800015
FC -1
DAIKIN
FTX12NMVJU
12,000 BTU/H
208 V 1PH MCA=1
00 L -BS
380
SCOPE OF WORK:
INSTALL (1) 1 TON DUCTLESS SPLIT HEAT
PUMP TO SERVE THE ELEVATOR MACHINE
ROOM.
LEGAL DESCRIPTION
MEADER HENRY -D C #46 COMM INTSN OF MONUMENT LN OF
SECONDARY ST HWY 2M, WEST VALLEY HWY, BEING 72 FT
WLY, MEAS AT R/A TO ELY MGN WITH MONUMENT LN OF S
158TH ST BEING 28 FT S OF AS MEAS AT R/A TO NLY R/W
LN SD INTSN BEING REPRESENTED BY A PUNCHED R/R SPIKE
TH N 07-41-30 W ALG MONUMENT LN SD SECONDARY HWY 2M
DIST 261.51 FT TH S 85-21-00 W 78.11 FT TO WLY R/W LN
& TPOB TH N 07-41-30 W 24839 FT TH N 88-04-26 W 170
FT M/L TO ELY LN OF ORDINARY HIGH WATER OF GREEN RIVER
AS EXISTED PRIOR TO C/L CHANNEL CHANGE OF GREEN RIVER
AS SHOWN ON SR 405 GREEN RIVER INTERCHANGE STA99+00
TO STA 120+00 APPROVED 1-30-62 TH SWLY ALG SD ELY LN
TAP FR WCH TPOB BEARS S 85-21-00 W FR SD PT TH N 85-21-00
E 440 FT M/L TO TPOB
z
ELEVATOR
MACHINE
RSM 9'X7'
FC -1
CONDENSATE PUMP
TO EXTERIOR
STAIR
f': r(&ED FOR:
Q N13, Chanical
Lfd
Electrical
dumbing
F' Uas Piping
of Tukwila
DIVISION
REFRIG, LINE
TO HP -1
L-hington
eating
. and
IP
conditioning
INC
Washington Heating
and AC, inc
13620 1 st Avenue South
Burien, Washington 98168
ph: (206) 860-3832 fax: (206) 860-3799
Contractor's License No.: WASHIHAO12LQ
www.washingtonheating.com
STAMP
No changes shalt be ma a to the scope
of work without prior pproval of
Tukwila Building !vision.
NUTS: Revisions vat require a ew plan submitt
and may include additional M Ma,
Plan review ,ppro+ I is subject to errors and omissions.
Approval of consi:r °lion documents does not autho iza
the violation of any dopted code or ordinance. Reccipt
of approved Field Q PY and conditions is acknowledged:
By:
Date:_ ir(h11f_
Of Tukwila,
Q DIVISION
REVIEWED FOR
ODE. COMPLIANCE
APPROVED
NOV 0 9 2016
AXT 9
City of Tukwi(a.
BUILDING DIViSION
RECEIVED
CITY OF TU KWILA
NOV 03 2016
PERMIT CENTER
OHP -1
HVAC,
FLD❑R PLAN
SCALE: 1/4" 1'-0"
ME -3100
DRAWING 17XES
HVAC FLOOR PLAN
{
"KIN
J
PROJECT MANAGER
DESIGNED BY
ML
ST
DRAWN BY
CHECKED BY
ST
Sr
SCALE
PROJECT NO.
AS NOTM
201M
THIS DRAWING IS THE SOLE PROPERTY OF WASHINGTON
HEATING & AIR CONDMONG, INC.
ANY REPRODUCTION,
DUPLICATION, ADDITIONS AND/OR
MODIFICATIONS REQUIRE
THE WRITTEN APPROVAL OF WASHINGTON
HEATING & AIR
CONDITIONING, INC.
SHEET NUMBER
AC 04