HomeMy WebLinkAboutPermit M16-0172 - BOILING POINT RESTAURANT - EXHAUST HOOD SYSTEMBOILING POINT
RESTAURANT
361 STRANDER BLVD
M16=0172
City of Tukwila
Department of Community Development
• 6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206-431-3670
Inspection Request Line: 206-438-9350
Web site: htto://www.TukwilaWA.gov
MECHANICAL PERMIT
Parcel No: 2623049064 . Permit Number: M16-0172
Address: 361 STRANDER BLVD Issue Date: 5/8/2017
Permit Expires On: 11/4/2017
Project Name: BOILING POINT RESTAURANT
Owner:
Name: REGENCY CENTERS LP
Address: PO BOX 790830 C/O PROPERTY TAX
DEPT, SAN ANTONIO, WA, 78279
Contact Person:
Name: KEITH TA Phone: (206) 683-1414
Address: 5930 1ST AVE S, SEATTLE, WA, 98108
Contractor:
Name: GREAT SUN CORP Phone: (206) 329-8027
Address: 5930 1ST AVE S , SEATTLE, WA,
98108-3248
License No: GREATSC951D1 Expiration Date: 4/5/2019
Lender:
Name:
Address: ,
DESCRIPTION OF WORK:
INSTALLING (1) TYPE 1 EXHAUST HOOD SYSTEM WITH MAKE UP AIR
Valuation of Work: $18,000.00 Fees Collected: $428.80
Type of Work: NEW Electrical Service Provided by: PUGEST SOUND ENERGY
Fuel type: GAS Water District: TUKWILA
Sewer District: TUKWILA
Current Codes adopted by the City of Tukwila:
International Building Code Edition:
2015
National Electrical Code:
2014
International Residential Code Edition:
2015
WA Cities Electrical Code:
2014
International Mechanical Code Edition:
2015
WAC 296-4613:
2014
Uniform Plumbing Code Edition:
2015
WA State Energy Code:
2015
International Fuel Gas Code:
2015
Permit Center Authorized Signature:
c
Date:87
I hearby certify that I have read and examined this permit and know the same to be true and correct. All
provisions of law and ordinances governing this work will be complied with, whether specified herein or not.
The granting of this permit does not presume to give authority to violate or cancel the provisions of any other
state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this
development permit and a ree to the conditions attached to this permit.
Signature: Date:
Print Name:L
This permit shall become null and void if the work is not commenced within 180 days for the date of issuance, or if
the work is suspended or abandoned for a period of 180 days from the last inspection.
PERMIT CONDITIONS:
1: Work shall be installed in accordance with the approved construction documents, and any changes made
during construction that are not in accordance with the approved construction documents shall be
resubmitted for approval.
2: All permits, inspection record card and approved construction documents shall be kept at the site of work
and shall be open to inspection by the Building Inspector until final inspection approval is granted.
3: All construction shall be done in conformance with the Washington State Building Code and the
Washington State Energy Code.
4: Remove all demolition rubble and loose miscellaneous material from lot or parcel of ground, properly cap
the sanitary sewer connections, and properly fill or otherwise protect all basements, cellars, septic tanks,
wells, and other excavations. Final inspection approval will be determined by the building inspector based
on satisfactory completion of this requirement.
5: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the
City of Tukwila Building Department (206-431-3670).
6: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila
Permit Center.
7: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an
approval of, any violation of any of the provisions of the building code or of any other ordinances of the City
of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other
ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction
documents and other data shall not prevent the Building Official from requiring the correction of errors in
the construction documents and other data.
8: ***MECHANICAL PERMIT CONDITIONS***
9: All mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila
Permit Center (206/431-3670).
10: Manufacturers installation instructions shall be available on the job site at the time of inspection.
11: Type 1 Hoods, the required grease duct leakage test and Ilight test shall be performed by a special
inspection and testing agency in accordance with I.M.C. Chapter 5.
12: The attached set of mechanical plans have been reviewed by The Tukwila Fire Marshals Office and are
acceptable with the following concerns:
13: A Type 1 hood shall be installed at or above all commercial cooking appliances and domestic cooking
appliances used for commercial purposes that produce grease vapors. Each required commercial kitchen
exhaust hood and duct system required by section 610 of the International Fire Code to have a Type 1 hood
shall be protected with an approved automatic fire -extinguishing system installed in accordance with this
code. (IFC 904.2.1 and IFC 904.11) Automatic fire -extinguishing systems shall comply with UL 300 or other
equivalent standards and shall be installed in accordance with the requirements of the listing. (NFPA 96,
10.2.3)
14: Type I hood systems shall be designed and installed to automatically activate the exhaust fan whenever
cooking operations occur. The activation of the exhaust fan shall occur through an interlock with the
cooking appliances, by means of heat sensors or by means of other approved methods. (IMC 507.2.1.1)
15: All new automatic fire -extinguishing systems and all modifications to existing automatic fire -extinguishing
systems shall have fire department review and approval of drawings prior to installation or modification.
16: Local U.L. central station supervision is required. (City Ordinance #2437)
17: All new fire alarm systems or modifications to existing systems shall have the written approval of The
Tukwila Fire Prevention Bureau. No work shall commence until a fire department permit has been
obtained. (City Ordinance #2437) (IFC 901.2)
18: An electrical permit from the City of Tukwila Building Department Permit Center (206-431-3670) is required
for this project.
19: Portable fire extinguishers shall be provided within a 30 -foot (9144 mm) travel distance of commercial -type
cooking equipment. Cooking equipment involving vegetable or animal oils.and fats shall be protected by a
Class K rated portable extinguisher. (IFC 904.11.5)
20: Portable fire extinguishers, not housed in cabinets, shall be installed on the hangers or brackets supplied.
Hangers or brackets shall be securely anchored to the mounting surface in accordance with the
manufacturer's installation instructions. Portable fire extinguishers having a gross weight not exceeding 40
pounds (18 kg) shall be installed so that its top is not more than 5 feet (1524 mm) above the floor. Hand-
held portable fire extinguishers having a gross weight exceeding 40 pounds (18 kg) shall be installed so that
its top is not more than 3.5 feet (1067 mm) above the floor. The clearance between the floor and the
bottom of the installed hand-held extinguishers shall not be less than 4 inches (102 mm). (IFC 906.7 and IFC
906.9)
21: Contact The Tukwila Fire Prevention Bureau to witness all required inspections and tests. (City Ordinances
#2436 and #2437)
22: Any overlooked hazardous condition and/or violation of the adopted Fire or Building Codes does not imply
approval of such condition or violation.
23: These plans were reviewed by Inspector 511. If you have any questions, please call Tukwila Fire Prevention
Bureau at (206)575-4407.
PERMIT INSPECTIONS REQUIRED
Permit Inspection Line: (206) 438-9350
1400
FIRE FINAL
1800
MECHANICAL FINAL
0609
PIPE/DUCT INSULATION
0701
ROUGH -IN MECHANICAL
0702
SMOKE DETECTOR TEST
0710
TYPE 1 HOOD AND DUCT
7
CITY OF TU%WIGA
Community Development Department
Permit Center
6300 Southcenter Blvd., Suite 100
Tukwila, WA 98188
hM://www.TukwilaWA.sov
SITE LOCATION
Mechanical Permit No. H G
Project No.
Date Application Accepted: 0
Date Application Expires:—� %
1—
LM
MECHANICAL PERMIT APPLICATION
Applications and plans must be complete in order to be accepted for plan review.
Applications will not be accepted through the mail or by fax.
**please print**
King Co Assessor's Tax No.: 262304-9064
Site Address:_ 361 Strander BlvdTukw i1 t I.y�- o I a Suite Number: Floor: IDU 4D
Tenant Name: Boiling Point Restaurant New Tenant: .... Yes ..No
CONTACT PERSON — person receiving all pmject
communication
Name: Keith Ta
Address: 59301 st Ave S.
City: Seattle State: WA Zip: 98108
Phone: (206) 683-1414 Fax: (206) 329-7945
E'er: kta@greatsuncorp.com
MECHANICAL CONTRACTOR INFORMATION
Cony Name: Great Sun
Address: 5930 1 st Ave S.
City: Seattle State: WA Zip: 98108
Phone: (206) 329-8027 Fax: (206) 329-7945
Contr Reg No.: GREATSC951 Di Exp Date: 03/17/2016
Tukwila Business License No.: 0995621
Valuation of project (contractor's bid price): $ 18,000
Describe the scope of work in detail:
Installing one Type I exhaust hood system with make up air
Use. Residential: New .......... ❑ Replacement ........ ❑
Commercial: New .......... 0 Replacement ........ ❑
Fuel T3=-. Electric ..... ❑ Gas ....... ® Other.
HAApplieatiDra\FormrAppUcMaw On UncM16 Appticati m\Mac amieal P.,M Apphoti. Re kwd 1-4.16.4aat
Revised: )aanwy=6
hh Page 1 of 2
Indicate type of mechanical work being installed and the quantity below:
Unit Type
Qty
Furnace <100k btu
Residential, Nighttime
Furnace >100k btu
1
Floor furnace
55 dB(A)
Suspended/wall/floor
mounted heater
57 dB(A)
1
Appliance vent
1
Repair or addition to
heat/refrig/cooling
system
47 dB(A)
Air handling unit
<10,000 cfm
65 dB(A)
Unit Type
Qty
Air handling unit
>10,000 cf n
Residential, Nighttime
Evaporator cooler
1
Ventilation fan
connected to sin a duct
55 dB(A)
Ventilation system
57 dB(A)
1
Hood and duct
1
Incinerator — domestic
47 dB(A)
Incinerator —
comm/industrial
65 dB(A)
Unit Type
Qty
Fire damper
Residential, Nighttime
Diffuser
Industrial
Thermostat
55 dB(A)
Wood/gas stove
57 dB(A)
1
Emergency enerator
Commercial
Other mechanical
equipment
47 dB(A)
60 dB(A)
65 dB(A)
Boiler/Compressor Qty
0-3 hp/100,000 btu
3-15 500,000 btu
15-30 hp/1,000,000 btu
30-50 hp/1,750,000 btu
50+bp/1,750,000 btu
Noise:
Mechanical units need to be in compliance with the Tukwila Noise Code. Maximum permissible sound levels are based on from where the sound is
created and where the sound is heard. Additionally, if sound can be heard from within a house at night in a residential zone it may not be allowed.
For more details, see TMC 8.22
District of Sound
Producing Source
District of Receiving Property
Residential, Daytime*
Residential, Nighttime
Commercial
Industrial
Residential
55 dB(A)
45 dB(A)
57 dB(A)
1
60 dB(A)
Commercial
57 dB(A)
47 dB(A)
60 dB(A)
65 dB(A)
Industrial
1 60 dB(A)
50 dB(A)
65 dB(A)
70 dB(A)
*Daytime means 7AM-I0PM, Monday through Friday and 8AM-10PM, Saturday, Sunday and State -recognized holidays.
A few sounds are exempt from the noise code, including.
Warning devices;
Construction and property maintenance during the daytime hours (7am-10pm);
Testing of backup generators during the day.
PERMIT APPLICATION NOTES
Value of construction — in all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject
to possible revision by the permit center to comply with current fee schedules.
Expiration of plan review — applications for which no permit is issued within 180 days following the date of application shall expire by limitation.
The building official may grant one extension of tithe for additional periods not to exceed 90 days each. The extension shall be requested in writing
and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition).
I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER
PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT.
BUILDING
AGENT:
Date. 10/28/2016
Print Name: Keith Ta Day Telephone: (206) 683-1414
Mailing Address: 59301 st Ave S. Seattle WA 98108
City State Zip
H:1Awhca wmo Form&-Applicahm On LmeW016 ApphcatiomMceMniul Pam* Appbcolou Reri ed 1-4.16.docx
Rewired: Janmy 2016 Page 2 of 2
6h
DESCRIPTIONS
•
QUANTITY
PAID
PermitTRAK
$4,737.02
D16-0302 Address: 3615TRANDER BLVD
Apn: 2623049064
$4,308.22
DEVELOPMENT
$4,181.64
PERMIT FEE
R000.322.100.00.00
0.00
$2,531.60
PLAN CHECK FEE
R000.345.830.00.00
0.00
$1,645.54
WASHINGTON STATE SURCHARGE
B640.237.114
0.00
$4.50
TECHNOLOGY FEE
$126.58
TECHNOLOGY FEE
R000.322.900.04.00
0.00
$126.58
M16-0172 Address: 3615TRANDER BLVD
Apn: 2623049064
$428.80
MECHANICAL
$412.31
PERMIT ISSUANCE BASE FEE
R000.322.100.00.00
0.00
$32.50
PERMIT FEE
R000.322.100.00.00
0.00
$297.35
PLAN CHECK FEE
R000.322.102.00.00
0.00
$82.46
TECHNOLOGY FEE
$16.49
TECHNOLOGY FEE
TOTALR9814
R000.322.900.04.00
0.00
$16.49
Date Paid: Monday, November 07, 2016
Paid By: LONGDON INC
Pay Method: CHECK 1245
Printed: Monday, November 07, 20161:28 PM 1 of 1 C
SYSTEMS
INSPECTION RECORD
7T]
Retain a copy with permit _ ��
INSPECTION NO. PERMIT NO.
CITY OF TUKWILA BUILDING DIVISION
6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-367
Permit Inspection Request Line (206) 438-9350
P ect:
&JUA(6- f�Wr
Ty a of Inspection: O
- I "I
__j
Address: �
Date Called:
Special Instructions:
Date Want d: a.m.
6� %-7
iRequestefr:
Phone No:
70& 13 l
Approved per applicable codes. LJ Corrections required prior to approval.
lJ paid at 6300 5outhcenter Blvd.. Suite 100. Call to schedule reinspection.
INSPECTION RECORD
Retain a copy with permit Frqiz :o17 2-
INSPECTION NO. PERMIT NO.
CITY OF TUKWILA BUILDING DIVISION
6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670
Permit Inspection Request Line (206) 438-9350
Approved per applicable codes. a Corrections required prior to approval.
(Inspector: (uate: rr/,�/�,� I
r] REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be
paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection.
INSPECTION RECORD
Retain a copy with permit � a �r J 72
INS TION NO. PERMIT NO.
CITY OF TUKWILA BUILDING DIVISION
6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670
Permit Inspection Request Line (206) 438-9350
Project:
Type of Inspection:
,�
P,� v
r✓c a �r�
Address:
Date Called:
Special Instructions:
Date Wanted: = a.m.
tf d l 7 ---p.m.
Requester:
Phone No:
Approved per applicable codes. Corrections required prior to approval.
F] REINSPECTION FEE REQUIRED. Prior to next inspection. fee must be
paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection.
INSPECTION RECORD
Retain a copy with permit��
INSPECTION NO. PERMIT NO.
CITY OF TUKWILA BUILDING DIVISION
6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670
Permit Inspection Request Line (206) 438-9350
P,Bect:
Pso L ,
Tpe of Inspection:
i> Ua�
Address:
3✓ / s'
Date Called:
Special Instructions:
,9 PE , ') j>
/`, �-�
Date Wanted_ H a.m.
p.m.
Requester:
Phone No:
U REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be
paid at 6300 Southcenter Blvd., Suite 100. Call. to schedule reinspection.
INSPECTION RECORD
Retain a copy with permit l�r Of 7
INSPE ON N0. PERMIT NO.
CITY OF TUKWILA BUILDING DIVISION
6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670
Permit Inspection Request Line (206) 438-9350 Z1
P 'ect:
Type of Inspection:
Address:
Date Called:
'?,� /
Special Instructions:
Date Want d: a
/
®�7 p.m.
Reques er:
llss��
`„ 9
16 �✓
Phone No:,
czZo6
- 6- = A
50
Approved per applicable codes. 1 Corrections required prior to approval.
I paid at 6300 Southcenter Blvd., Suite 100. Cali to schedule reinspection.
INSPECTION RECORD
`Retain a copry"with pefrnit'
INSPECTION NUMBER
FAVE
PERMIT NUMBERS
CITY OF TUKWILA FIRE DEPARTMENT
206-575-4407
Project:5-6iL1b-'
� e�1 N !
Type of Inspec ion:
e
Address:
131
Contact Person:
Suite #: ..>�'""
Pre -Fire:
Special Instructions:
Phone No..
O��roved per applicable codes. 2--c-orrections required prior to approval.
COMMENTS:
o
® �,•
Needs Shift Inspection:
Sprinklers:
Fire Alarm:
Hood & Duct:
Monitor:
Pre -Fire:
Permits:
Occupancy Type:
Inspector: I Date: I Hrs.:
$100.00 REINSPECTION FEE REQUIRED. You will receive an invoice from
the City of Tukwila Finance Department. Call to schedule a reinspection.
Billing Address
Attn: Company Name:
Address:
City: State: Zi
Word/Inspection Record Form.Doc 3/14/14 T.F.D. Form F.P. 113
4/3/2017
City of Tukwila Allan Ekberg, Mayor
Department of Community Development Jack Pace, Director
KEITH TA
5930 1 STAVE S
SEATTLE, WA 981.08
RE: Permit Application No. M 16-0172
BOILING POINT RESTAURANT
361 STRANDER BLVD
Dear KEITH TA,
In reviewing our current application files, it appears that your permit applied for on 11/7/2016, has not been issued by the City of
Tukwila Permit Center. Per the International Building Code, International Mechanical Code, Uniform Plumbing Code and/or
National Electrical Code every permit application not issued within 180 days from the date of application shall expire and become
null and void. Currently your application has a status of APPROVED and is due to expire on 5/7/2017.
If you still plan to pursue your project, you are hereby advised to do one of the following:
1) If the plan review is complete for the project and your application is approved, you may pick up,the application before
the date of expiration. At the time of permit issuance the expiration date will automatically be extended 180 days.
-or-
2) If the plan review is not completed submit a written request for application extension (7) seven days in advance of the
expiration date. Address your extension request to the Building Official and state your reason(s) for the need to extend your
application.
The Building Code does allow the Building Official to approve one extension of up to 90 days. If it is determined that your extension
request is granted, you will be notified by mail.
In the event that we do not receive your written request for extension or request is denied, your permit application will expire and
your project will require a new permit application, plans and specifications, and associated fees.
Thank you for your cooperation in this matter.
Sincerely,
Rachelle Ripley
Permit Technician
File No: M16-0172
6300 Southcenter Boulevard Suite #100 • Tukwila Washington 98188 • Phone 206-431-3670 • Fax 206-431-3665
PERMIT COORD COPi(
PLAN REVIEW/ROUTING SLIP
PERMIT NUMBER: M16-0172
DATE: 11/07/16
PROJECT NAME: BOILING POINT RESTAURANT
SITE ADDRESS: 361 STRANDER BLVD
X Original Plan Submittal Revision # before Permit Issued
Response to Correction Letter #
Revision # after Permit Issued
DEPARTMENTS: W
NO
A,-- oc
10
Building Division Fire Prevention Planning Division ❑
Public Works ❑ Structural ❑ Permit Coordinator
PRELIMINARY REVIEW: DATE: 11/08/16
Not Applicable ❑ Structural Review Required ❑
(no approval/review required)
REVIEWER'S INITIALS: DATE:
APPROVALS OR CORRECTIONS: DUE DATE: 12/06/16
Approved ❑ Approved with Conditions ❑
Corrections Required ❑ Denied ❑
(corrections entered in Reviews) (ie: Zoning Issues)
Notation:
REVIEWER'S INITIALS:
DATE:
Permit Center Use Only
CORRECTION LETTER MAILED:
Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials:
12/18/2013
GREAT SUN CORP
Washington State Department of
"Labor & Industries
GREAT SUN CORP
Owner or tradesperson
Principals
TA, KEVIN, PRESIDENT
Doing business as
GREAT SUN CORP
WA UBI No.
601 984 317
Horne Espanol Contact
Safety & Health Claims & Insurance
5930 1 st Ave S
SEATTLE, WA 98108
206-329-8027
KING County
Business type
Corporation
Governing persons
KEVIN
Page 1 of 2
SearchL&I
A -Z Index Help My L&I
Workplace Rights Trades & Licensing
TA
MIKE AU YONG;
YEN LEE;
CHAU TAN;
License
Verify the contractor's active registration / license / certification (depending on trade) and any past violations.
Construction Contractor Active.
............................
Meets current requirements.
License specialties
Heating/Vent/Air-Conditioning and Refrig
(HVAC/R)
License no.
GREATSC951D1
Effective -- expiration
03/21/2005— 04/05/2019
Bond
$1,000,000.00
Philadelphia Indemnity Ins Co
$6,000.00
Bond account no.
PB03138600212
Effective date
Received by L&I
Effective date
02/09/2012
03/10/2012
Expiration date
Until Canceled
Bond history
Insurance
Liberty Mutual Ins Co
$1,000,000.00
Policy no.
BKS57287371
Received by L&I
Effective date
09/07/2016
06/15/2016
Expiration date
06/15/2017
Insurance history
Savings
Help us improve
https:Hsecure.Ini.wa.gov/verify/Detail.aspx?UBI=601984317&LIC=GREATSC95 I D 1 &SAW= 5/8/2017
GREAT SUN CORP Page 2 of 2
No savings accounts during the previous 6, teriod.
Lawsuits against the bond or savings
No lawsuits against the bond or savings accounts during the previous 6 year period.
L&I Tax debts
No L tax debts are recorded for this contractor license during the previous 6 year period, but some debts
may be recorded by other agencies.
License Violations
.......................................................
No license violations during the previous 6 year period.
Workers' comp
Do you know if the business has employees? If so, verify the business is up-to-date on workers' comp premiums.
L&1 Account ID Account is current.
980,066-00
.................................
Doing business as
GREAT SUN
Estimated workers reported
Quarter 4 of Year 2016 " 7 to 10 Workers"
L&I account representative
T3 / STEPHANIE HENDERSON (360)902.5598 - Email: HSTE235@lni.wa.gov
Workplace safety and health
Check for any past safety and health violations found on jobsites this business was responsible for
Inspection results date
06/27/2016 Violations
Inspection no.
317939757
Location
424 7 th Avenue S.
Seattle, WA 98134
Inspection results date
11/26/2014 Violations
Inspection no.
317583748
Location
5930 1 st Ave S
Seattle, WA 98108
Inspection results date
04/09/2014 Violations
Inspection no.
316957307
Location
505S Lander St
Seattle, WA 98134
Washington State Dept. of Labor & Industries. Use of this site is subject to the laws of the state of Washington.
Help us improve
https:Hsecure.Ini:wa.gov/verify/Detail.aspx?UBI=601984317&LIC=GREATSC95 I D 1 &SAW= 5/8/2017
TYPICAL UNISTRUT HOOD SUPPORT DETAILS
A 12 GA. "U" CHANNEL
OBAR SUPPORT
VU
2%2" Lo Root Lubricized \w�
Round Washer Recex Screw 3l8" THREADED
STEEL ROD -
B
Part M 50943 No. 14 (Non -Combustible) MAKE UP AIR
1Y" Hex. Washer Self Drill Screw SECTION
EXHAUST
3" No. 10 METAL FASTENERS SECTION
BETWEEN WALL STUD &
SUPPORT BRACKET w BRACKET
ION CENTER OFF FRAMING STUDS) ,ti' ,:�� I WELDED
ONTO HOOD
(A) 2.5" METAL FASTENERS,
BETWEEN MWALL &
WALL FRAME(C)16 GA. GALVANIZE
SUPPORT BRACKET
METALSTUD
WAXS/S
" METAL FASTENERS
BETWEEN HOOD &
SUPPORT BRACKET;
ND OFF
ASHING , ,
W
< 0
ry
W Q
n
C.7 W
f�
OU)
00 0�
= W
(Dn
z
W D
z N%_Wi
20 GA. STAINLESS
STEEL TYPE 1
GREASE HOOD
iB GA. GALVANIZE
HOOD BRACKET
1.2
NOTES:
FIREMASTER GREASE DUCT SYSTEM: 1. THE EXHAUST FAN & MAKE UP AIR SYSTEM WILL BE
CONNECTED BY AN ELECTRICAL INTERLOCKING SWITCH
1 OR 2 HOUR SHAFT ALTERNATIVE & ZERO FOR SAME TIME OPERATION.
CLEARANCE TO COMBUSTIBLE CONSTRUCTION 2. ALL EQUIPMENT SHOWN ON THIS DRAWING SHALL
BE AS SPECIFIED OR EQUAL.
3. THE PROPOSED WALL TO BE CONSTRUCTED TO MEET THE FIRE
CODES FOR TYPE 1 HOOD (1 HR. FIRE RESISTIVE SHIELD).
4. STAINLESS STEEL SHEET SHALL COVER THE ENTIRE
COOKING AREA,
5. ALL HOOD, DUCT JOINS, & SEAMS SHALL BE EXTERNAL
GREASE TIGHT WELD.
6. EXHAUST FAN SHALL BE 40" (MIN.) DISCHARGE ABOVE ROOF.
7. MIN. DISTANCE BETWEEN EXHAUST FAN & MAKE UP AIR
SHALL BE NO LESS THAN 10'.
8. FIRE SUPPRESSION SYSTEM WILL BE UNDER SEPERATE PERMIT.
SCOPE OF WORK:
INSTALL ONE 16' COMMERICAL KITCHEN (TYPE 1) GREASE HOOD,
TWO EXHAUST FANS, ONE MAKE UP AIR UNITS, & RELATED DUCT
WORK FOR BOTH FANS
PROJECT INFORMATION:
TENANT: BOILING POINT
361 STRANDER BLVD
TUKWILA, WA 98188
PROPERTY OWNER: REGENCY CENTER LP
PARCEL TAX ACCOUNT: 262304-9064
LEGAL DESDRIPTION: LOT 1 OF CITY OF TUKWILA SHORT PLAT NO 91 -9 -SS
RECORDING NO 9208261819 SAID SHORT PLAT DAF - FOR OF SW 1/4 OF NE 1/4 -
BEG SW COR OF NE 1/4 TH N 01-10-24 E 1293.57 FT TO S MGN OF STRANDER
BLVD TH S 88-15-33 E 665 FT TO POB TH S 01-44-27 W 63 FT TAP OF TANGENT
CURVE CONCAVE TO NE RAD OF 130 FT TH SELY ALG SD CURVE THRU ARC OF
34-27-01 ARC LENGTH OF 78.17 FT TH S 88-15-33 E 212.17 FT TH S 01-44-27 W 62
FT TH S 88-15-33 E 9 FT TH S 01-44-27 W 62 FT TH N 88-15-33 W 133 FT TH S
01-44-27 W 150 FT TH N 88-15-33 W 482.33 FT TH S 48-28-37 W 113.91 FT TH S
01-44-27 W 37.10 FT TH N 88-15-33 W 120 FT TH S 01-44-27 W 80 FT TH N 8B-15-33
W 84.69 FT TO W LN OF SAID SW 1/4 TH S 01-10-24 W 687.83 FT TO SW CORNER
OF NE 1 /4 TH S 88-06-43 E 1309.38 FT TO W MGN OF ANDOVER PARK WEST TH N
01-03-25 E 1296.97 FT TO S MGN OF STRANDER BLVD TH N 88.15-33 W 641.71 FT
TO POB--- AKA LOT 2 OF CITY OF TUKWILA LOT LN ADJ NO 88-6-BLA RECORDING
NO 8901240241 --- LESS PORTION FOR R/W TO CITY OF TUKWILA
1
2 LAYER FIRE BARRIER DUCT WRAP
2
FILAMENT TAPE
3
BANDING
4
3" PERIMETER OVERLAP
5
3" LONGITUDINAL OVERLAP
6
12" DIAMETER HANGER ROD
7
1 1/2" x 1 1/2'x 1/8" ANGLE
PARKING LOT REVISIONS
Pio changes shall he made to the scope
of work without prior approval of
Tukwila Building Division.
NOTE: Revisions will require a new plan submittal
and aydnclude addit%QnaLplan review fees
JOBSITE
r ,
MIN. 10-7
r
EF
#1
zN,
-- -
NOTE:
ALL ROOF TOP UNITS
ARE 20'+ AWAY FROM
ALL SIDES OF THE
20'+ ROOF EDGE.
xe �x SITE/ROOF PLAN
SCALE: Y .1'
EXHAUST HINDGE KIT
INSTALLATION
�A
HINDGE
BRACKET
ROOF LINE-�
CABLE
_ ROOF
CURB
GREASE
SEE 1.2
UNIT
BRAND
FIREWRAP
CFM
HORSE
S.P.
ELECTRICAL
EXHAUST
FAN #2
(THERMAFLEX) 7
G•KM FLEXIBLE �,
INSULATED AIR DUCT t
`•
16" x 16" ALL AROUND
TIGHT
WELDED GREASE i;, 'i.• an
DUCT (16 GA. •.,
GALVANIZE STEEL)B ,,,,,,;•
GHT
NAME
vJ
62 J
(REQUIRED)
POWER(VOLTAGE)/(PHASE)
q r q �+
PP,hNL: x=I AUW i
1ir0UiPFD FOR:,:
❑ Mechanical
�' Plumbing
�GaS PipingAIR
City Of Tukwila
DIVISION
FIREWRAP
SEE 1.2
12 GA.
UNISTRUT
(THERMAFLEX)
G -KM FLEXIBLE
DUCT
3/8" THREADEDCONTINUOUS
STEEL ROD
(FRONT SUPPORT)MUA DUCT
BANDING
(L
ALL AROUND
EXHAUST
DAYTON
CONTINUOUS TIGHT
2,400
Y2" THREADED
WELDED 16 GA.
(115/208-230)/(1 PH)
STEEL ROD
GALVANIZE DUCT
, _4
(FRONT SUPPORT)
,._6...
Q
�
cC
nc�Ca
24 GA. GALVANIZE
ALL AROUND
5PV07
MAKE UP AIR DUCT
CONTINUOUS TIGHT
0.75"
4'
WELD BETWEEN DUCT
FAN #2
AND HOOD SYSTEM
LIGHT
MAKEUP
ESSIK
MAKE UP
3" STAINLESS STEEL
3/4
AIR VENTS
(20 GA.) FLASH
1 5
FILTER
SEE 1.1
C0
GREASE
METAL STUD
0
a o
u•G
L0 O
GUTTER 18 GA. STAINLESS STEEL
WALL FRAME
•
(4'x 16') TYPE I GREASE HOOD
3'_9..
5/8" TYPE "X"
FIRE RATED
SHEET ROCK
INLESS STEEL
WALL W/ ROXUL1
COOKING
AFBA HR FIRE PAD
EQUIPMENT
VINCINITY MAP
SCALE: NTS
NORTH
FAN EQUIPMENT SCHEDULE
UNIT
BRAND
MODEL #
CFM
HORSE
S.P.
ELECTRICAL
EXHAUST
FAN #2
(THERMAFLEX) 7
G•KM FLEXIBLE �,
INSULATED AIR DUCT t
`•
16" x 16" ALL AROUND
TIGHT
WELDED GREASE i;, 'i.• an
DUCT (16 GA. •.,
GALVANIZE STEEL)B ,,,,,,;•
GHT
NAME
vJ
62 J
(REQUIRED)
POWER(VOLTAGE)/(PHASE)
q r q �+
PP,hNL: x=I AUW i
1ir0UiPFD FOR:,:
❑ Mechanical
�' Plumbing
�GaS PipingAIR
City Of Tukwila
DIVISION
FIREWRAP
SEE 1.2
12 GA.
UNISTRUT
(THERMAFLEX)
G -KM FLEXIBLE
DUCT
3/8" THREADEDCONTINUOUS
STEEL ROD
(FRONT SUPPORT)MUA DUCT
BANDING
(L
S)
EXHAUST
DAYTON
5PV07
2,400
1
0.75"
(115/208-230)/(1 PH)
145
FAN #1
, _4
a-
inM
,._6...
Q
�
cC
nc�Ca
EXHAUST
DAYTON
5PV07
2,400
1
0.75"
(115/208-230)/(1 PH)
1 5
FAN #2
MAKEUP
ESSIK
7AC39
4,800
3/4
0.3"
(115-230)!(1 PH)
1 5
AIR #1
C0
®CCS
W
O
TW
i�
WElectrical
elft"'I
S
BUILDING
L
LAM C
EXHAUST
40" MIN.
FAN #1
'
EXHAUST
FAN #2
(THERMAFLEX) 7
G•KM FLEXIBLE �,
INSULATED AIR DUCT t
`•
16" x 16" ALL AROUND
TIGHT
WELDED GREASE i;, 'i.• an
DUCT (16 GA. •.,
GALVANIZE STEEL)B ,,,,,,;•
20 GA.
FLASHING
'
vJ
62 J
ca
LL M
q r q �+
PP,hNL: x=I AUW i
1ir0UiPFD FOR:,:
❑ Mechanical
�' Plumbing
�GaS PipingAIR
City Of Tukwila
DIVISION
FIREWRAP
SEE 1.2
12 GA.
UNISTRUT
(THERMAFLEX)
G -KM FLEXIBLE
DUCT
3/8" THREADEDCONTINUOUS
STEEL ROD
(FRONT SUPPORT)MUA DUCT
BANDING
r'i;r
`,;.; ~•
;;', '•;.• . '. r.
'
t• +•,;
SUSPENDED "T" J
BAR CEILING
CC)PY
as
O
1 4
1._4.,
V
20 GA.
FLASH
, _4
a-
inM
,._6...
Q
�
cC
SECTION ELEVAT16N VIEW
SCALE: Y2=1'
Type I Hood Special Inspections
Type I hoods and ducts shall be inspected by
approved inspection agencies that satisfy the
requirements as to qualifications and reliability. Final
inspection reports from such approved agencies of the
Type I hood and duct shall be accepted by the code
official after the special inspections of hood and duct
have been completed.
(2012 IMC 107.2.4 & IMC 506.3.2.5)
SEE NOTES
MI
24 GA. GALVANIZE
MAKE UP DUCT -I
MAKE UP
AIR
Y2" THEA
STEEL ODD RECEIVED
(FRONT SUPPORT) CITY OF TUKWILA
20NOV 017 2016
FLASHING
PERMIT CENTER
��.-0�2000 000
W 20 GA. STAINLESS STEEL WALL
w/ 1" ROXUL FIRE PAD
��.., 1'-6" 8' 8' 1'-6"
.<absr '^A 1 � ° :.d vat to errors and on -lis -cions. I 6" MIN. - 6
,Tpprova'Iof cry ,� � , d;� °oclu llosits does not r_u'L c i_3
the violation of any adopted code or ordinance. Reccipt
of approved Field Copy ar d conditions is acknowledgod:
By:
Date: , SAS -
City Of Tukwila
BUILD)
O O O
6" MIN.
m00=000=0 I 0=000=000=0 I 0=:O00=000=0
FRONT VIEW
SCALE: %2 =1'
EQUIPMENT
1.) TYPE 1 HOOD SYSTEM <4'(W) x 16'(L)>
2.) 6 BURNER RANGE <36"(W) x 56"(H)>
3.) DOUBLE STOCK POT RANGE <18"(W) x 20"(H)>
4.) GAS RICE COOKER <18"(W) x 18"(H)>
En
LAM C
00
M�00
W
oo
0)
�0<
`D Z
vJ
62 J
ca
LL M
i -
0C
E
as
G
v
otS
V
IL�ING DIVISION
y
a-
inM
�
Q
�
cC
nc�Ca
C
y _I d
c U)
l0
CO
rw
y
C0
0
a o
u•G
L0 O
•
Type I Hood Special Inspections
Type I hoods and ducts shall be inspected by
approved inspection agencies that satisfy the
requirements as to qualifications and reliability. Final
inspection reports from such approved agencies of the
Type I hood and duct shall be accepted by the code
official after the special inspections of hood and duct
have been completed.
(2012 IMC 107.2.4 & IMC 506.3.2.5)
SEE NOTES
MI
24 GA. GALVANIZE
MAKE UP DUCT -I
MAKE UP
AIR
Y2" THEA
STEEL ODD RECEIVED
(FRONT SUPPORT) CITY OF TUKWILA
20NOV 017 2016
FLASHING
PERMIT CENTER
��.-0�2000 000
W 20 GA. STAINLESS STEEL WALL
w/ 1" ROXUL FIRE PAD
��.., 1'-6" 8' 8' 1'-6"
.<absr '^A 1 � ° :.d vat to errors and on -lis -cions. I 6" MIN. - 6
,Tpprova'Iof cry ,� � , d;� °oclu llosits does not r_u'L c i_3
the violation of any adopted code or ordinance. Reccipt
of approved Field Copy ar d conditions is acknowledgod:
By:
Date: , SAS -
City Of Tukwila
BUILD)
O O O
6" MIN.
m00=000=0 I 0=000=000=0 I 0=:O00=000=0
FRONT VIEW
SCALE: %2 =1'
EQUIPMENT
1.) TYPE 1 HOOD SYSTEM <4'(W) x 16'(L)>
2.) 6 BURNER RANGE <36"(W) x 56"(H)>
3.) DOUBLE STOCK POT RANGE <18"(W) x 20"(H)>
4.) GAS RICE COOKER <18"(W) x 18"(H)>
En
_ o
0>
00
M�00
W
oo
0)
�0<
`D Z
vJ
62 J
LL M
i -
W
7v'ER
UJI
IL�ING DIVISION
Lji" DETAIL- COOLER WALL PANEL TO CONCRETE ;
%I'AlI nILIF-1
_LEIS
VIA LL PANEL
Trap & Terminate above
floor sink per local codes
CAM LOCK DETAIL
��JN.T.S.
%"x6"Round head bolt
I i %" USS flat v
Air flow %8' Nut
Evap. 9
Drain pan
Drain line & Evap. Detail
(Typical)
Exit at nearest point
Copper tubing Min. Pitch y"
Per foot wrap inside portion
with heater if it A freezer.
CAM -LOCK
N.T.S.ovoaT�oo
DETAIL -CEILING
II
ao o �vav�w oawa, o� o<
Q 4 v4 4 v v� v d vv v v v vv vv 4v v v vvvvv_V111 v
�
..r •.
EXTEROR
CO
INTERIOR
� •r.,N �\CHSID[ h!T°RIOR
51
f RDF tTNI'i Y: k'`rtf Fila' Nr
WAIL"AnFLI"Ar.ANET1.CM
.—.INSULATEDL'iALLI�A,DJ-L 5
ti:C I11 ATrf wwLl F.
55
COnTINUOI JS DEAD
all—YL 5@ kLF;hT ++
• •
5'S
011 K I ;;W (Fh1�FIF17MFNV.1 H IT 01-108 Fy'
i ++
O.'RCwANCIIOP.1r4' c,,CDUAL(24"a,C) '+
1f.GA z" x21-.
4
+
;'
CSR REP ORT =7
DAwC ANGLC"
+
t
+
G#311CP,(2.1"o.0 1 a COXV `•,
rALTCRNAT@ D RCCTION OF CONOnCTC `
P0,711ASE 01:.l h WINr1 DIJ1
CAAT
•5 I I__I I —' I I—I I— I I --I I— I —I I—I I �—I I I—I I I I "/
Lji" DETAIL- COOLER WALL PANEL TO CONCRETE ;
%I'AlI nILIF-1
_LEIS
VIA LL PANEL
Trap & Terminate above
floor sink per local codes
CAM LOCK DETAIL
��JN.T.S.
%"x6"Round head bolt
I i %" USS flat v
Air flow %8' Nut
Evap. 9
Drain pan
Drain line & Evap. Detail
(Typical)
Exit at nearest point
Copper tubing Min. Pitch y"
Per foot wrap inside portion
with heater if it A freezer.
CAM -LOCK
N.T.S.ovoaT�oo
DETAIL -CEILING
II
ao o �vav�w oawa, o� o<
Q 4 v4 4 v v� v d vv v v v vv vv 4v v v vvvvv_V111 v
I.
DOOR ACCESSICLITY MOTE:
; � �;, 1 38 H NLK= 1, HARDWARE ON ALL DOORS SHALL MEET
HANDICAP HEIGHTS, CLOSURE PRESSURE.
3-23/312+lf ` , 21 PRESSURE SMALL 140T EXCEED 6 LBS, ON
EXTERIOR AND INTERIOR DOORS, I. LBS. FOR
FIRE DOORS •
I4OUtNTINU 14'0LES 70---, , D14 . ' Cup 3. HARDWARE HEIGHT TO MEET REQUIREMENT
SUIT FASTENERS OF 2'-10" TO 3'- 8" CENTERLINE OFF MOUNTING
A.F1F1
_ •= _ -- .— _ _ . _ _ _ _ . _ _ y_ . , ..; _ . _ _'
4. NO FLOOR TRANSITION OR THRESHOLD
_•...,. _ _•--,._ RTF�%N 112(HANDICAP
.
BEFALL BE HIGHS
_. ..�-..... REQUIRENIEN .
MI OPERABLE DOOR PARTS SHALL BE
•�f32 (lir DEEP OPERABLE WITH ONE RAND AND SHALL NOT
REQUIRE TIGHT GRASPING, PITCHING, OR
TWISTING OF THE WRIST, (CBC 1 I E; ODA)
6, SEE CBC 11 B-309, CBC 11E-404.2.7)
ti
_ DOC�'.ti�m
$_ KNOB
PER WASHINGTON STATE ENERGY CODE REQUIREMENTS:
1. DOORS SHALL BE PROVIDED WITH SPRING -HINGED DOORS
2. FOR WALK-IN COOLERS, PROVIDE DOOR INSULATION OF AT LEAST R-25.
3. FOR WALK-IN FREEZER, PROVIDE DOOR INSULATION OF AT LEAST R-32.
4. FOR WALK-IN FREEZER, PROVIDE FLOOR INSULATION OF AT LEAST R-28.
T LONG x 1'!'!, UNI STRUTS
' 14LIT 3 j2) i+tiASHERS
BJTYL'+CAULIttI4G f
_ r TY3'..
'ALL THREAD .
- AIAN G[R rzoo.:
,, TI ICU PANEIr�
CEILING PANEL---"
ti THREAD 11IRLI
COIL [3RA,CKET
F' --A it Cl
COIL SUPPORT DETAIL
�ri T Y
Spring ui, ,lf r1 r,,,• e..fn fi, r) r r rrlFS( .
7.5'-15'
Front Elevation
DOOR DETIALS
Ceiling Panel
SITE PLAN
SCALE: NTS
NORTH
sulking — ZJ LI—
Ught Fixture Walk -In Cooler Walk -In Freezer
9'x6'x8'(H) 9'x4'x8'(H) ,
EVAPORATIVE EVAPORATIVE
FAN FAN
r- --- ------
W
-- -iW/ Filet Ught I I I I
I I I 1
L - - - - - - - - - ' L - - - - - - - - - '
Panel
CONDESING CONDESING
Light Switch to Light Fixture
COMMERCIAL COOLER, INC.
M F.e. NLl.n Cada, F.w.em
B.x sea n» co.+r'olmuro
7 O
Nn waam.uslrai ueroly
T l0]E)f50U1.tE CONFD6T
Fu.ryml>;omn IMtmM1�a�k K ett.. ,e
NEIGHBORIN
ASSEMBLY
CONFIGURATION
�MERCIAL CCOOLI INC.
*Separate Mechanical Permit shall
be required for: Coolers, freezers,
walk-in coolers and freezers, i.e.
assembled and hardwired.
*Self-contained "plugin" coolers
or freezers (appliance type) shall
not require a mechanical permit.
NEIGHBORING TENANT
SITE / PLAN VIEW
NORTH
SCALE: Ys" = 1'
NOV 0'7 2016
PERMIT CENTER
0
W
LL
11--
0 0
0
LIC
0.
REVIEWED FO
CODE COMPLIAt
APPROVED
ljov 2.2 2016
City of Tukwil
BUILDING DI ION
SHEET NUMBER
�
•
..r •.
CO
Ir—
J.•
•
0-P F
REVIEWED FO
CODE COMPLIAt
APPROVED
ljov 2.2 2016
City of Tukwil
BUILDING DI ION
SHEET NUMBER
TYPICAL UNISTRUT HOOD SUPPORT DETAILS
A 12 GA. "U" CHANNEL
OBAR SUPPORT
VU
2%2" Lo Root Lubricized \w�
Round Washer Recex Screw 3l8" THREADED
STEEL ROD -
B
Part M 50943 No. 14 (Non -Combustible) MAKE UP AIR
1Y" Hex. Washer Self Drill Screw SECTION
EXHAUST
3" No. 10 METAL FASTENERS SECTION
BETWEEN WALL STUD &
SUPPORT BRACKET w BRACKET
ION CENTER OFF FRAMING STUDS) ,ti' ,:�� I WELDED
ONTO HOOD
(A) 2.5" METAL FASTENERS,
BETWEEN MWALL &
WALL FRAME(C)16 GA. GALVANIZE
SUPPORT BRACKET
METALSTUD
WAXS/S
" METAL FASTENERS
BETWEEN HOOD &
SUPPORT BRACKET;
ND OFF
ASHING , ,
W
< 0
ry
W Q
n
C.7 W
f�
OU)
00 0�
= W
(Dn
z
W D
z N%_Wi
20 GA. STAINLESS
STEEL TYPE 1
GREASE HOOD
iB GA. GALVANIZE
HOOD BRACKET
1.2
NOTES:
FIREMASTER GREASE DUCT SYSTEM: 1. THE EXHAUST FAN & MAKE UP AIR SYSTEM WILL BE
CONNECTED BY AN ELECTRICAL INTERLOCKING SWITCH
1 OR 2 HOUR SHAFT ALTERNATIVE & ZERO FOR SAME TIME OPERATION.
CLEARANCE TO COMBUSTIBLE CONSTRUCTION 2. ALL EQUIPMENT SHOWN ON THIS DRAWING SHALL
BE AS SPECIFIED OR EQUAL.
3. THE PROPOSED WALL TO BE CONSTRUCTED TO MEET THE FIRE
CODES FOR TYPE 1 HOOD (1 HR. FIRE RESISTIVE SHIELD).
4. STAINLESS STEEL SHEET SHALL COVER THE ENTIRE
COOKING AREA,
5. ALL HOOD, DUCT JOINS, & SEAMS SHALL BE EXTERNAL
GREASE TIGHT WELD.
6. EXHAUST FAN SHALL BE 40" (MIN.) DISCHARGE ABOVE ROOF.
7. MIN. DISTANCE BETWEEN EXHAUST FAN & MAKE UP AIR
SHALL BE NO LESS THAN 10'.
8. FIRE SUPPRESSION SYSTEM WILL BE UNDER SEPERATE PERMIT.
SCOPE OF WORK:
INSTALL ONE 16' COMMERICAL KITCHEN (TYPE 1) GREASE HOOD,
TWO EXHAUST FANS, ONE MAKE UP AIR UNITS, & RELATED DUCT
WORK FOR BOTH FANS
PROJECT INFORMATION:
TENANT: BOILING POINT
361 STRANDER BLVD
TUKWILA, WA 98188
PROPERTY OWNER: REGENCY CENTER LP
PARCEL TAX ACCOUNT: 262304-9064
LEGAL DESDRIPTION: LOT 1 OF CITY OF TUKWILA SHORT PLAT NO 91 -9 -SS
RECORDING NO 9208261819 SAID SHORT PLAT DAF - FOR OF SW 1/4 OF NE 1/4 -
BEG SW COR OF NE 1/4 TH N 01-10-24 E 1293.57 FT TO S MGN OF STRANDER
BLVD TH S 88-15-33 E 665 FT TO POB TH S 01-44-27 W 63 FT TAP OF TANGENT
CURVE CONCAVE TO NE RAD OF 130 FT TH SELY ALG SD CURVE THRU ARC OF
34-27-01 ARC LENGTH OF 78.17 FT TH S 88-15-33 E 212.17 FT TH S 01-44-27 W 62
FT TH S 88-15-33 E 9 FT TH S 01-44-27 W 62 FT TH N 88-15-33 W 133 FT TH S
01-44-27 W 150 FT TH N 88-15-33 W 482.33 FT TH S 48-28-37 W 113.91 FT TH S
01-44-27 W 37.10 FT TH N 88-15-33 W 120 FT TH S 01-44-27 W 80 FT TH N 8B-15-33
W 84.69 FT TO W LN OF SAID SW 1/4 TH S 01-10-24 W 687.83 FT TO SW CORNER
OF NE 1 /4 TH S 88-06-43 E 1309.38 FT TO W MGN OF ANDOVER PARK WEST TH N
01-03-25 E 1296.97 FT TO S MGN OF STRANDER BLVD TH N 88.15-33 W 641.71 FT
TO POB--- AKA LOT 2 OF CITY OF TUKWILA LOT LN ADJ NO 88-6-BLA RECORDING
NO 8901240241 --- LESS PORTION FOR R/W TO CITY OF TUKWILA
1
2 LAYER FIRE BARRIER DUCT WRAP
2
FILAMENT TAPE
3
BANDING
4
3" PERIMETER OVERLAP
5
3" LONGITUDINAL OVERLAP
6
12" DIAMETER HANGER ROD
7
1 1/2" x 1 1/2'x 1/8" ANGLE
PARKING LOT REVISIONS
Pio changes shall he made to the scope
of work without prior approval of
Tukwila Building Division.
NOTE: Revisions will require a new plan submittal
and aydnclude addit%QnaLplan review fees
JOBSITE
r ,
MIN. 10-7
r
EF
#1
zN,
-- -
NOTE:
ALL ROOF TOP UNITS
ARE 20'+ AWAY FROM
ALL SIDES OF THE
20'+ ROOF EDGE.
xe �x SITE/ROOF PLAN
SCALE: Y .1'
EXHAUST HINDGE KIT
INSTALLATION
�A
HINDGE
BRACKET
ROOF LINE-�
CABLE
_ ROOF
CURB
GREASE
SEE 1.2
UNIT
BRAND
FIREWRAP
CFM
HORSE
S.P.
ELECTRICAL
EXHAUST
FAN #2
(THERMAFLEX) 7
G•KM FLEXIBLE �,
INSULATED AIR DUCT t
`•
16" x 16" ALL AROUND
TIGHT
WELDED GREASE i;, 'i.• an
DUCT (16 GA. •.,
GALVANIZE STEEL)B ,,,,,,;•
GHT
NAME
vJ
62 J
(REQUIRED)
POWER(VOLTAGE)/(PHASE)
q r q �+
PP,hNL: x=I AUW i
1ir0UiPFD FOR:,:
❑ Mechanical
�' Plumbing
�GaS PipingAIR
City Of Tukwila
DIVISION
FIREWRAP
SEE 1.2
12 GA.
UNISTRUT
(THERMAFLEX)
G -KM FLEXIBLE
DUCT
3/8" THREADEDCONTINUOUS
STEEL ROD
(FRONT SUPPORT)MUA DUCT
BANDING
(L
ALL AROUND
EXHAUST
DAYTON
CONTINUOUS TIGHT
2,400
Y2" THREADED
WELDED 16 GA.
(115/208-230)/(1 PH)
STEEL ROD
GALVANIZE DUCT
, _4
(FRONT SUPPORT)
,._6...
Q
�
cC
nc�Ca
24 GA. GALVANIZE
ALL AROUND
5PV07
MAKE UP AIR DUCT
CONTINUOUS TIGHT
0.75"
4'
WELD BETWEEN DUCT
FAN #2
AND HOOD SYSTEM
LIGHT
MAKEUP
ESSIK
MAKE UP
3" STAINLESS STEEL
3/4
AIR VENTS
(20 GA.) FLASH
1 5
FILTER
SEE 1.1
C0
GREASE
METAL STUD
0
a o
u•G
L0 O
GUTTER 18 GA. STAINLESS STEEL
WALL FRAME
•
(4'x 16') TYPE I GREASE HOOD
3'_9..
5/8" TYPE "X"
FIRE RATED
SHEET ROCK
INLESS STEEL
WALL W/ ROXUL1
COOKING
AFBA HR FIRE PAD
EQUIPMENT
VINCINITY MAP
SCALE: NTS
NORTH
FAN EQUIPMENT SCHEDULE
UNIT
BRAND
MODEL #
CFM
HORSE
S.P.
ELECTRICAL
EXHAUST
FAN #2
(THERMAFLEX) 7
G•KM FLEXIBLE �,
INSULATED AIR DUCT t
`•
16" x 16" ALL AROUND
TIGHT
WELDED GREASE i;, 'i.• an
DUCT (16 GA. •.,
GALVANIZE STEEL)B ,,,,,,;•
GHT
NAME
vJ
62 J
(REQUIRED)
POWER(VOLTAGE)/(PHASE)
q r q �+
PP,hNL: x=I AUW i
1ir0UiPFD FOR:,:
❑ Mechanical
�' Plumbing
�GaS PipingAIR
City Of Tukwila
DIVISION
FIREWRAP
SEE 1.2
12 GA.
UNISTRUT
(THERMAFLEX)
G -KM FLEXIBLE
DUCT
3/8" THREADEDCONTINUOUS
STEEL ROD
(FRONT SUPPORT)MUA DUCT
BANDING
(L
S)
EXHAUST
DAYTON
5PV07
2,400
1
0.75"
(115/208-230)/(1 PH)
145
FAN #1
, _4
a-
inM
,._6...
Q
�
cC
nc�Ca
EXHAUST
DAYTON
5PV07
2,400
1
0.75"
(115/208-230)/(1 PH)
1 5
FAN #2
MAKEUP
ESSIK
7AC39
4,800
3/4
0.3"
(115-230)!(1 PH)
1 5
AIR #1
C0
®CCS
W
O
TW
i�
WElectrical
elft"'I
S
BUILDING
L
LAM C
EXHAUST
40" MIN.
FAN #1
'
EXHAUST
FAN #2
(THERMAFLEX) 7
G•KM FLEXIBLE �,
INSULATED AIR DUCT t
`•
16" x 16" ALL AROUND
TIGHT
WELDED GREASE i;, 'i.• an
DUCT (16 GA. •.,
GALVANIZE STEEL)B ,,,,,,;•
20 GA.
FLASHING
'
vJ
62 J
ca
LL M
q r q �+
PP,hNL: x=I AUW i
1ir0UiPFD FOR:,:
❑ Mechanical
�' Plumbing
�GaS PipingAIR
City Of Tukwila
DIVISION
FIREWRAP
SEE 1.2
12 GA.
UNISTRUT
(THERMAFLEX)
G -KM FLEXIBLE
DUCT
3/8" THREADEDCONTINUOUS
STEEL ROD
(FRONT SUPPORT)MUA DUCT
BANDING
r'i;r
`,;.; ~•
;;', '•;.• . '. r.
'
t• +•,;
SUSPENDED "T" J
BAR CEILING
CC)PY
as
O
1 4
1._4.,
V
20 GA.
FLASH
, _4
a-
inM
,._6...
Q
�
cC
SECTION ELEVAT16N VIEW
SCALE: Y2=1'
Type I Hood Special Inspections
Type I hoods and ducts shall be inspected by
approved inspection agencies that satisfy the
requirements as to qualifications and reliability. Final
inspection reports from such approved agencies of the
Type I hood and duct shall be accepted by the code
official after the special inspections of hood and duct
have been completed.
(2012 IMC 107.2.4 & IMC 506.3.2.5)
SEE NOTES
MI
24 GA. GALVANIZE
MAKE UP DUCT -I
MAKE UP
AIR
Y2" THEA
STEEL ODD RECEIVED
(FRONT SUPPORT) CITY OF TUKWILA
20NOV 017 2016
FLASHING
PERMIT CENTER
��.-0�2000 000
W 20 GA. STAINLESS STEEL WALL
w/ 1" ROXUL FIRE PAD
��.., 1'-6" 8' 8' 1'-6"
.<absr '^A 1 � ° :.d vat to errors and on -lis -cions. I 6" MIN. - 6
,Tpprova'Iof cry ,� � , d;� °oclu llosits does not r_u'L c i_3
the violation of any adopted code or ordinance. Reccipt
of approved Field Copy ar d conditions is acknowledgod:
By:
Date: , SAS -
City Of Tukwila
BUILD)
O O O
6" MIN.
m00=000=0 I 0=000=000=0 I 0=:O00=000=0
FRONT VIEW
SCALE: %2 =1'
EQUIPMENT
1.) TYPE 1 HOOD SYSTEM <4'(W) x 16'(L)>
2.) 6 BURNER RANGE <36"(W) x 56"(H)>
3.) DOUBLE STOCK POT RANGE <18"(W) x 20"(H)>
4.) GAS RICE COOKER <18"(W) x 18"(H)>
En
LAM C
00
M�00
W
oo
0)
�0<
`D Z
vJ
62 J
ca
LL M
i -
0C
E
as
G
v
otS
V
IL�ING DIVISION
y
a-
inM
�
Q
�
cC
nc�Ca
C
y _I d
c U)
l0
CO
rw
y
C0
0
a o
u•G
L0 O
•
Type I Hood Special Inspections
Type I hoods and ducts shall be inspected by
approved inspection agencies that satisfy the
requirements as to qualifications and reliability. Final
inspection reports from such approved agencies of the
Type I hood and duct shall be accepted by the code
official after the special inspections of hood and duct
have been completed.
(2012 IMC 107.2.4 & IMC 506.3.2.5)
SEE NOTES
MI
24 GA. GALVANIZE
MAKE UP DUCT -I
MAKE UP
AIR
Y2" THEA
STEEL ODD RECEIVED
(FRONT SUPPORT) CITY OF TUKWILA
20NOV 017 2016
FLASHING
PERMIT CENTER
��.-0�2000 000
W 20 GA. STAINLESS STEEL WALL
w/ 1" ROXUL FIRE PAD
��.., 1'-6" 8' 8' 1'-6"
.<absr '^A 1 � ° :.d vat to errors and on -lis -cions. I 6" MIN. - 6
,Tpprova'Iof cry ,� � , d;� °oclu llosits does not r_u'L c i_3
the violation of any adopted code or ordinance. Reccipt
of approved Field Copy ar d conditions is acknowledgod:
By:
Date: , SAS -
City Of Tukwila
BUILD)
O O O
6" MIN.
m00=000=0 I 0=000=000=0 I 0=:O00=000=0
FRONT VIEW
SCALE: %2 =1'
EQUIPMENT
1.) TYPE 1 HOOD SYSTEM <4'(W) x 16'(L)>
2.) 6 BURNER RANGE <36"(W) x 56"(H)>
3.) DOUBLE STOCK POT RANGE <18"(W) x 20"(H)>
4.) GAS RICE COOKER <18"(W) x 18"(H)>
En
_ o
0>
00
M�00
W
oo
0)
�0<
`D Z
vJ
62 J
LL M
i -
W
7v'ER
UJI
IL�ING DIVISION
Lji" DETAIL- COOLER WALL PANEL TO CONCRETE ;
%I'AlI nILIF-1
_LEIS
VIA LL PANEL
Trap & Terminate above
floor sink per local codes
CAM LOCK DETAIL
��JN.T.S.
%"x6"Round head bolt
I i %" USS flat v
Air flow %8' Nut
Evap. 9
Drain pan
Drain line & Evap. Detail
(Typical)
Exit at nearest point
Copper tubing Min. Pitch y"
Per foot wrap inside portion
with heater if it A freezer.
CAM -LOCK
N.T.S.ovoaT�oo
DETAIL -CEILING
II
ao o �vav�w oawa, o� o<
Q 4 v4 4 v v� v d vv v v v vv vv 4v v v vvvvv_V111 v
�
..r •.
EXTEROR
CO
INTERIOR
� •r.,N �\CHSID[ h!T°RIOR
51
f RDF tTNI'i Y: k'`rtf Fila' Nr
WAIL"AnFLI"Ar.ANET1.CM
.—.INSULATEDL'iALLI�A,DJ-L 5
ti:C I11 ATrf wwLl F.
55
COnTINUOI JS DEAD
all—YL 5@ kLF;hT ++
• •
5'S
011 K I ;;W (Fh1�FIF17MFNV.1 H IT 01-108 Fy'
i ++
O.'RCwANCIIOP.1r4' c,,CDUAL(24"a,C) '+
1f.GA z" x21-.
4
+
;'
CSR REP ORT =7
DAwC ANGLC"
+
t
+
G#311CP,(2.1"o.0 1 a COXV `•,
rALTCRNAT@ D RCCTION OF CONOnCTC `
P0,711ASE 01:.l h WINr1 DIJ1
CAAT
•5 I I__I I —' I I—I I— I I --I I— I —I I—I I �—I I I—I I I I "/
Lji" DETAIL- COOLER WALL PANEL TO CONCRETE ;
%I'AlI nILIF-1
_LEIS
VIA LL PANEL
Trap & Terminate above
floor sink per local codes
CAM LOCK DETAIL
��JN.T.S.
%"x6"Round head bolt
I i %" USS flat v
Air flow %8' Nut
Evap. 9
Drain pan
Drain line & Evap. Detail
(Typical)
Exit at nearest point
Copper tubing Min. Pitch y"
Per foot wrap inside portion
with heater if it A freezer.
CAM -LOCK
N.T.S.ovoaT�oo
DETAIL -CEILING
II
ao o �vav�w oawa, o� o<
Q 4 v4 4 v v� v d vv v v v vv vv 4v v v vvvvv_V111 v
I.
DOOR ACCESSICLITY MOTE:
; � �;, 1 38 H NLK= 1, HARDWARE ON ALL DOORS SHALL MEET
HANDICAP HEIGHTS, CLOSURE PRESSURE.
3-23/312+lf ` , 21 PRESSURE SMALL 140T EXCEED 6 LBS, ON
EXTERIOR AND INTERIOR DOORS, I. LBS. FOR
FIRE DOORS •
I4OUtNTINU 14'0LES 70---, , D14 . ' Cup 3. HARDWARE HEIGHT TO MEET REQUIREMENT
SUIT FASTENERS OF 2'-10" TO 3'- 8" CENTERLINE OFF MOUNTING
A.F1F1
_ •= _ -- .— _ _ . _ _ _ _ . _ _ y_ . , ..; _ . _ _'
4. NO FLOOR TRANSITION OR THRESHOLD
_•...,. _ _•--,._ RTF�%N 112(HANDICAP
.
BEFALL BE HIGHS
_. ..�-..... REQUIRENIEN .
MI OPERABLE DOOR PARTS SHALL BE
•�f32 (lir DEEP OPERABLE WITH ONE RAND AND SHALL NOT
REQUIRE TIGHT GRASPING, PITCHING, OR
TWISTING OF THE WRIST, (CBC 1 I E; ODA)
6, SEE CBC 11 B-309, CBC 11E-404.2.7)
ti
_ DOC�'.ti�m
$_ KNOB
PER WASHINGTON STATE ENERGY CODE REQUIREMENTS:
1. DOORS SHALL BE PROVIDED WITH SPRING -HINGED DOORS
2. FOR WALK-IN COOLERS, PROVIDE DOOR INSULATION OF AT LEAST R-25.
3. FOR WALK-IN FREEZER, PROVIDE DOOR INSULATION OF AT LEAST R-32.
4. FOR WALK-IN FREEZER, PROVIDE FLOOR INSULATION OF AT LEAST R-28.
T LONG x 1'!'!, UNI STRUTS
' 14LIT 3 j2) i+tiASHERS
BJTYL'+CAULIttI4G f
_ r TY3'..
'ALL THREAD .
- AIAN G[R rzoo.:
,, TI ICU PANEIr�
CEILING PANEL---"
ti THREAD 11IRLI
COIL [3RA,CKET
F' --A it Cl
COIL SUPPORT DETAIL
�ri T Y
Spring ui, ,lf r1 r,,,• e..fn fi, r) r r rrlFS( .
7.5'-15'
Front Elevation
DOOR DETIALS
Ceiling Panel
SITE PLAN
SCALE: NTS
NORTH
sulking — ZJ LI—
Ught Fixture Walk -In Cooler Walk -In Freezer
9'x6'x8'(H) 9'x4'x8'(H) ,
EVAPORATIVE EVAPORATIVE
FAN FAN
r- --- ------
W
-- -iW/ Filet Ught I I I I
I I I 1
L - - - - - - - - - ' L - - - - - - - - - '
Panel
CONDESING CONDESING
Light Switch to Light Fixture
COMMERCIAL COOLER, INC.
M F.e. NLl.n Cada, F.w.em
B.x sea n» co.+r'olmuro
7 O
Nn waam.uslrai ueroly
T l0]E)f50U1.tE CONFD6T
Fu.ryml>;omn IMtmM1�a�k K ett.. ,e
NEIGHBORIN
ASSEMBLY
CONFIGURATION
�MERCIAL CCOOLI INC.
*Separate Mechanical Permit shall
be required for: Coolers, freezers,
walk-in coolers and freezers, i.e.
assembled and hardwired.
*Self-contained "plugin" coolers
or freezers (appliance type) shall
not require a mechanical permit.
NEIGHBORING TENANT
SITE / PLAN VIEW
NORTH
SCALE: Ys" = 1'
NOV 0'7 2016
PERMIT CENTER
0
W
LL
11--
0 0
0
LIC
0.
REVIEWED FO
CODE COMPLIAt
APPROVED
ljov 2.2 2016
City of Tukwil
BUILDING DI ION
SHEET NUMBER
�
•
..r •.
CO
Ir—
J.•
•
0-P F
REVIEWED FO
CODE COMPLIAt
APPROVED
ljov 2.2 2016
City of Tukwil
BUILDING DI ION
SHEET NUMBER