Loading...
HomeMy WebLinkAboutPermit M16-0174 - UNITED RENTALS - EXHAUST FANUNITED RENTALS 17700 W VALLEY Bl\VY M16-0174 ON of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Inspection Request Line: 206-438-9350 Web site: http://www.TukwifaWA.gov Parcel No: 3623049057 Address: 17700 W VALLEY HWY Project Name: UNITED RENTALS MECHANICAL PERMIT Permit Number: M16-0174 Issue Date: 2/10/2017 Permit Expires On: 8/9/2017 Owner: 2015 National Electrical Code: Name: UNITED RENTALS INC 2015 Address: 13727 NOEL ROAD STE 900 C/O International Mechanical Code Edition: 2015 FISCHER & CO URI, DALLAS, WA, 2014 Uniform Plumbing Code Edition: 75240 WA State Energy Code: Contact Person: International Fuel Gas Code: 2015 Name: TERESE ANDERSON Phone: (253) 796-5825 Address: 1221 SECOND AVE N, KENT, WA, Date: 2 �� 98032 Contractor: Name: HERMANSON COMPANY LLP Phone: (206) 575-9700 Address: 1221 2ND AVE N, KENT, WA, 98032- 2945 License No: HERMACL005BJ Expiration Date: 8/25/2018 Lender: Name: Address: DESCRIPTION OF WORK: INSTALL ONE NEW EXHAUST FAN SERVING THE WAREHOUSE Valuation of Work: $5,433.00 Fees Collected: $276.62 Type of Work: NEW Electrical Service Provided by: PUGEST SOUND ENERGY Fuel type: ELECT Water District: RENTON Sewer District: RENTON Current Codes adopted by the City of Tukwila: International Building Code Edition: 2015 National Electrical Code: 2014 International Residential Code Edition: 2015 WA Cities Electrical Code: 2014 International Mechanical Code Edition: 2015 WAC 296-46B: 2014 Uniform Plumbing Code Edition: 2015 WA State Energy Code: 2015 International Fuel Gas Code: 2015 Permit Center Authorized Signature: Date: 2 �� I hearby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this development permit and agree to the conditions attached to this permit. Signature Print Nam Date: This permit shall become null and void if the work is not commenced within 180 days for the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. PERMIT CONDITIONS: 1: Work shall be installed in accordance with the approved construction documents, and any changes made during construction that are not in accordance with the approved construction documents shall be resubmitted for approval. 2: All permits, inspection record card and approved construction documents shall be kept at the site of work and shall be open to inspection by the Building Inspector until final inspection approval is granted. 3: All construction shall be done in conformance with the Washington State Building Code and the Washington State Energy Code. 4: Remove all demolition rubble and loose miscellaneous material from lot or parcel of ground, properly cap the sanitary sewer connections, and properly fill or otherwise protect all basements, cellars, septic tanks, wells, and other excavations. Final inspection approval will be determined by the building inspector based on satisfactory completion of this requirement. 5: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center. 6: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. 7: `MECHANICAL PERMIT CONDITIONS' 8: All mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center (206/431-3670). 9: Manufacturers installation instructions shall be available on the job site at the time of inspection. PERMIT INSPECTIONS REQUIRED Permit Inspection Line: (206) 438-9350 1800 MECHANICAL FINAL 0701 ROUGH -IN MECHANICAL CITY OF TUKWI. Community Development Department Permit Center • 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 qqRg" http://www.TulcwilaWA.gov Mechanical Permit No. �l [ j (`7Y Project No. Date Application Accepted:��� Date Application Expires: 5 use MECHANICAL PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. "please print" SITE LOCATION King Co Assessor's Tax No.: 3623049057 Site Address: 17700 West Valley Hwy Tukwila WA 98188 Suite Number: Floor: Tenant Name: United Rentals New Tenant: ❑ .....Yes ®..No PROPERTY OWNER Name: United Rentals Address: City: State: Zip: CONTACT PERSON — person receiving all project communication Name: Terese Anderson Address: 1221 2nd Ave N City: Kent State: WA Zip: 98032 Phone: (206) 200-7804 Fax: Email: tanderson@hermanson.com Valuation of project (contractor's bid price): $ 5,433 MECHANICAL CONTRACTOR INFORMATION Company Name: Hermanson Address: 1221 2nd Ave N City: Kent State: WA Zip: 98032 Phone: (206) 575-9700 Fax: Contr Reg No.: hermacl005bj Exp Date: 08/25/2017 Tukwila Business License No.: BUS00994464 Describe the scope of work in detail: installing one new exhaust fan serving the warehouse Use: Residential: New .......... ❑ Replacement ........ ❑ Commercial: New .......... ® Replacement ........ ❑ Fuel Type: Electric..... ® Gas ....... ❑ Other:_ H: Applications Forms -Applications On Line201 I Applications.Mechanical Permit Application Revised 8-9-1 I.docx Revised: August 2011 Page 1 of 2 bh Indicate type of mechanical work being installed and the quantity below: Unit Type Qty Furnace <100k btu Furnace >I 00k btu Floor furnace 1 Suspended/wall/floor mounted heater Appliance vent Repair or addition to heat/refrig/cooling system Air handling unit <10,000 cfm Unit Type Qty Air handling unit >I0,000 cfm Evaporator cooler Ventilation fan connected to single duct 1 Ventilation system Hood and duct Incinerator — domestic Incinerator — comm/industrial Unit Type Qty Fire damper Diffuser Thermostat Wood/gas stove Emergency enerator Other mechanical equipment Boiler/Compressor Qty 0-3 hp/100,000 btu 3-15 h /500,000 btu 15-30 hp/l ,000,000 btu 30-50 hp/1,750,000 btu 50+ h /1,750,000 btu PERMIT APPLICATION NOTES - Value of construction — in all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the permit center to comply with current fee schedules. Expiration of plan review — applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The building official may grant one extension of time for additional periods not to exceed 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDIP Signature Print Name: Terese Anderson Mailing Address: 1221 2nd Ave N Day T Kent City Date: (206) 200-7804 WA 98032 State Zip H: Applications Forms -Applications On Linc,201 I Applications Mechanical Permit Application Revised 3-9-1 l.docx Revised: August 201 I Page 2 of 2 bh DESCRIPTIONS ACCOUNTQUANTITY PAID PermitTRAK $383.11 EL16-1062 Address: 17700 W VALLEY HWY Apn: 3623049057 $106.49 ELECTRICAL $101.42 PERMIT FEE MULTI-FAM/COMM R000.322.101.00.00 0.00 $101.42 TECHNOLOGY FEE $5.07 TECHNOLOGY FEE R000.322.900.04.00 0.00 $5.07 M16-0174 Address: 17700 W VALLEY HWY Apn: 3623049057 $276.62 MECHANICAL $265.98 PERMIT ISSUANCE BASE FEE R000.322.100.00.00 0.00 $32.50 PERMIT FEE R000.322.100.00.00 0.00 $180.28 PLAN CHECK FEE R000.322.102.00.00 0.00 $53.20 TECHNOLOGY FEE $10.64 TECHNOLOGY FEE TOTAL RECEIPT:.$383.11 R000.322.900.04.00 0.00 $10.64 Date Paid: Friday, November 18, 2016 Paid By: KAYLENE NELSON Pay Method: CREDIT CARD 850068 Printed: Friday, November 18, 2016 1:01 PM 1 of 1 SYSTEMS INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Requester: Project: PATI -IED RENML-S Type of Inspection: I ,,Try W C -A -L r1/1.1-1 Address: 17706 W, YOttiLE y 110 Date Called: Special Instructions: Date Wanted: a.m. `/6- p.m. Requester: Phone No: XApproved per applicable codes. L, Corrections required prior to approval. REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. uREENHECK Printed Date: 9/19/2016 Job: United Rental Building Value in Air.L L A Mark: Mark 3 Model: CWB-240-15 Model: CWB-240-15 Belt Drive Centrifugal Sidewall Exhaust Fan — — — Dimensional Quantity 1 Weight w/o Acc's (lb) 133 Weight w/ Acc's (lb) Max T Motor Frame Size 145 184 Optional Damper (in.) 20 x 20 Wall Opening (in.) 20.5 x 20.5 _ Performance jested Volume (CFM) 6,000 -'Actual Volume (CFM) External SP (in. wg) 6,000 0.25 Total SP (in. wg) 0.25 Fan RPM Operating Power (hp) 721 1 _ Elevation (ft) 30 Airstream Temp.(F) Air Density (Ib/ft3) 70 0.075 Drive Loss (%) Tip Speed (ft/min) 6.2 4,626 Static Eff. (%) 25 Motor Motor Mounted Yes Size (hp) 1 1/2 Voltage/Cycle/Phase 208/60/1 Enclosure ODP Motor RPM 1725 Windings 1 NEC FLA" (Amps) 11 1.2 ED 0.6 N a> lir 2 0.3 M CF 31.25 28.38 'Overall height may be greater depending on motor 0 1 Operating Bhp poi Operating point at Operating point at Fan curve - System curve ------ Brake horsepower M1b0*41017y Sound Power by Octave Band Sound 62.5 125 250 500 1000 2000 4000 8000 LwA dBA gonDataInlet 79 86 7973 71 67 58 53 77 66 2 3 4 5 Volume (CFM) x 1,0 REVIEWED FOR E COMPLIANCE ernal XppROVED FEB 0 2 2011 1.2 W a t 0.6 3 0 11 a) Y M 0.3 m 0.0 6 7 RECEIVED CITY OF TIJKWILA NOV 18 2016 City of Tukla PERMIT CENTER �dtING ?,e!�'ts SION own of in. 'NEC FLA - based on tables 430.248 or 430.250 of National Electrical Code 2014. Actual motor FLA may vary, for sizing thermal overload, consult factory. LwA - A weighted sound power level, based on ANSI S1.4 dBA - A weighted sound pressure level, based on 11.5 dB attenuation per Octave band at 5 It - dBA levels are not licensed by AMCA International Sones - calculated using AMCA 301 at 5 ft amca� IpORIDGIIDE 010TIRD R9T1116t sound NPEYEOR 45R, Generated by: matt@dorse.com CAPS 4.21.1504 \\COHO\Public\Matt\wincaps\Jobs\United Rental.gfcj Page 1 of 5 LNGREENHECK Printed Date: 9/19!201 yob: United Rental Building Value in Air. Mark: Mark 3 Model: WB -240-15 Model: CWB-240-15 Belt Drive Centrifugal Sidewall Exhaust Fan Standard Construction Features: - Aluminum housing - Backward inclined aluminum wheel - Birdscreen mounted to the discharge perimeter - Removable mounting plate - Ball bearing motors - Motor and drives isolated on shock mounts - Adjustable motor pulley - Adjustable motor plate - Fan shaft mounted in ball bearing pillow blocks - Bearing meet or exceed temperature rating of fan - Static free belts - Corrosion resistant fasteners Selected Options & Accessories: Motor with Capacitor Start Motor with Thermal Overload UL/cUL 705 Listed -"Power Ventilators" Switch, NEMA -1, Toggle, Shipped with Unit Junction Box Mounted & Wired Damper Shipped Loose, WD -323 -PB -20X20, Gravity Operated, Not Coated Birdscreen: Galvanized Bearings with Grease Fittings, L10 life of 100,000 hrs (1-50 avg. life 500,000 hrs) Unit Warranty: 1 Yr (Standard) icefft .},'� Generated by: matt@dorse.com CAPS 4.21.1504 \\COHO\Public\Matt\wincaps\Jobs\United Rental.gfcj Page 2 of 5 � GREENHECK Printed Date: 9/19/2016 Job: United Rental ® Building Value in Air. Mark: Mark 3 Model: CWB-240-15 Assembly Drawing Type: Belt Drive Centrifugal Sidewall Exhaust Fan 42.8 Dia. NOTE: Overall height may be greater depending on motor 33.9 20.5 SUGGESTED WALL OPENING — 25.5 20.0 EXHAUST DAMPER & DUCTWORK 028.4i 1 Mounting Hole Pattern 31.3 20.0 20.5 I j TOP AND SIDE VIEW END VIEW Notes: All dimensions shown are in units of in.. Generated by: matt@dorse.com CAPS 4.21.1504 \\COHO\Public\Matt\wincaps\Jobs\United Rental.gfcj Page 3 of 5 ®t, GREENHECK Printed Date: 9/19/2016 Job: United Rentai Building Value in AiMark: Mark 3 -MS Model: MSAC-1 PH -1 -1 8/J -G 13-40 Motor Starter Advanced Control with (sniln��-s-Tn�T" Qty: 1 Model: MSAC-1PH-1-18/J-G13-40 Standard Construction Features: NEMA and IEC, dual -rated contactor — HOA keypad — Hand, off, auto, run and fault lights — Conduit plate knockouts — Solid- state, electronic overload — Stall protection — Locked rotor trip — Max start time monitoring — Overload out of calibration protection —Adjustable power failure restart mode — 3 inputs for remote control; 12-250V direct voltage input, N.O.dry contact and fireman's override — 2 output relays; motor status and fault alarm — Damper actuator control, 24VDC, 30VA max — Damper limit switch input - UL, cUL Motor Starter Configuration: Series: I Type: I Enclosure: Material: HP: Power: Nema Size: MSAC I Combination I NEMA -1 16 Ga Steel 1 1 1/2 1 208/60/1 1 0 Contactor NEMA Size Rated Operational Voltage Rated Insulation Voltage Rated Thermal Current 3e (0 <= 55 C) [HP] 200V 240V 460V I 500V MRC -18 0 690V 1000V 5 7.5 10 1 15 I Overload (Trip Classl OL Reset I OL Type IFLA Rangel Phase Unbalance I Phase Loss l MSAC 1 10 or 20 1 Manual or Auto I Electronic Thermal I 1-40A I Trip in 3 sec @ 25% Trip in 3 sec Disconnect Part Number Rated Operational Current [A] Magnetic Release Operating Current [A] Protection Max Short Circuit Current [KAIC] Degree I 200/240V I 480V 600V CMS-32HI-13 13 169 IP20 1 0-0—f 50 10 MSAC CONTROL WIRING 15 0(A0)35 525 130 FL1 40 w tr OVERLOAD SETTING Rrao1 O p OFF AUTO O O RUN O FAULT KEYPAD PCB POWER H1 H4 12-250V V4 VOLTAGE AUTO V3 INPUT 12-250V V2 VOLTAGE FIREMAN'S OVERRIDE Vt INPUT STATUS 02 N.O. OUTPUT FAULT O 01 COMMON N.O. OUTPUT 06 N.C. DRY SHUTDOWN D5INPUT JSD (Remove to wire shutdown switch) DRY PERMISS 04 N.O. D3 INPUT JPS (Remove to wire 02 Permissive switch) N.O. DRY AUTO D1 INPUT DAMPER/ACTUATOR A { I DAMPER OUTPUT A -Q_ LIMIT SWITCH L+ N.O. L- INPUT JOS (Remove to wire damper switch) C« CONTACTOR COIL D A2 M Al 24V OUTPUT TO CONTACTOR COIL o z< �6' 4S �s MSAC STARTER POWER WIRING 200-600 VAC INPUT L1 L2 MCP 0 OPTIONAL OL It M L� L o L1—"S 1 T1 T2 T3 3b2` 4 AUX CONTACTS 4 MTR 1PH >> 5 MTG Notes: 6942T4895AR aYdRASMts of in. CAPS 4.21.1504 \\COHO\Public\Matt\wincaps\Jobs\United Rental.gfcj Page 4 of 5 lh r L.O.GREENHECK Building Value in Air. Vertical Mount Exhaust Damper Model: WD -323 Damper Configuration: F-1.3 L t F--12.3 Max. 1. 6.553 Printed Date: 9/19/2016 Job: United Rental Standard Construction Features: - Model WD -323 is a vertical mount exhaust damper and is constructed of extruded aluminum with pre - punched mounting holes - Damper blades are 0.025 in. roll formed aluminum with vinyl seals on the closing edge - Steel axles are 0.188 in. diameter zinc plated steel - Synthetic sleeve type bushings I ID #: I Tag: I Quantity: I W (in.): I H (in.): I Act Qty: I Actuator Model: I 4 1 Mark 3 1 1 1 20 20 0 Notes: All dimensions shown are in units of in. Width And height furnished approximately 0.125 in. undersize Generated by: matt@dorse.com CAPS 4.21.1504 \\COHO\Public\Matt\wincaps\Jobs\United Rental.gfcj Page 5 of 5 City of Tukwila Department of Community Development December 01, 2016 TERESE ANDERSON 1221 SECOND AVE N KENT, WA 98032 RE: Correction Letter # 1 MECHANICAL Permit Application Number M 16-0174 UNITED RENTALS - 17700 W VALLEY HWY Dear TERESE ANDERSON, Allan Ekberg, Mayor Jack Pace, Director This letter is to inform you of corrections that must be addressed before your development permit can be approved. All correction requests from each department must be addressed at the same time and reflected on your drawings. I have enclosed comments from the following departments: BUILDING - M DEPARTMENT: KC ELLIS at 206-431-3677 if you have questions regarding these comments. • Clarify the quantity and location of make-up air per IMC 501.4. Provide engineer's calculations for the size of natural ventilation openings that equal the amount of exhausted air of 6000 cfm. Please address the comments above in an itemized format with applicable revised plans, specifications, and/or other documentation. The City requires that two 2 sets of revised plan pages, specifications and/or other documentation be resubmitted with the appropriate revision block. In order to better expedite your resubmittal, a 'Revision Submittal Sheet' must accompany every resubmittal. I have enclosed one for your convenience. Corrections/revisions must be made in person and will not be accepted through the mail or by a messenger service. If you have any questions, I can be reached at 206-431-3655. Sincerely, _6C Bill Rambo Permit Technician File No. M16-0174 6300 Southcenter Boulevard Suite #100 • Tukwila Washington 98188 • Phone 206-431-3670 • Fax 206-431-3665 PE9,41IT i3OORD COPY PLAN REVIEW/ROUTING SLIP PERMIT NUMBER: M16-0174 DATE: 01/31/17 PROJECT NAME: UNITED RENTALS SITE ADDRESS: 17700 W VALLEY HWY Original Plan Submittal Revision # before Permit Issued X Response to Correction Letter # 1 Revision # after Permit Issued DEPARTMENTS: GAJ I�Nf� � Building Division Fire Prevention ❑ Planning Division ❑ Public Works ❑ Structural ❑ Permit Coordinator ❑ PRELIMINARY REVIIEW: DATE: 01/31/17 Not Applicable ❑ Structural Review Required ❑ (no approvalfreview required) REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: DUE DATE: 02/28/17 Approved ❑ Approved with Conditions ❑ Corrections Required ❑ Denied ❑ (corrections entered in Reviews) (ie: Zoning Issues) Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ , Ping ❑ PW ❑ Staff Initials: 17/18/2013 r'ERMIT COORD COPY. PLAN REVIEW/ROUTING SLIP PERMIT NUMBER: M16-0174 DATE: 11/18/16 PROJECT NAME: UNITED RENTALS SITE ADDRESS: 17700 W VALLEY HWY X Original Plan Submittal Response to Correction Letter # DEPARTMENTS: VkL,7 Building Division Fire Prevention Revision # before Permit Issued Revision # after Permit Issued Planning Division ❑ Public Works ❑ Structural ❑ Permit Coordinator PRELIMINARY REVIEW: DATE: 11/22/16 Not Applicable ❑ Structural Review Required ❑ (no approval/review required) REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: DUE DATE: 12/20/16 Approved ❑ Approved witb Conditions ❑ Corrections Required (corrections entered in Reviews) Notation: REVIEWER'S INITIALS: Denied ❑ (ie: Zoning Issues) DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg Fire ElPing F-1PW [IStaff Initials: 12/18/2013 vb City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Fax: 206-431-3665 Web site: htW://www.ci.tuhwila.wa.us REVISION SUBMITTAL Revision submittals must be submitted in person at the Permit Center. Revisions will not be accepted through the mail, fax, etc. Date: 12/9/2016 Plan Check/Permit Number: M16-0174 ❑ Response to Incomplete Letter # _ ® Response to Correction Letter # 1 ❑ Revision # after Permit is Issued RECEIVED ❑ Revision requested by a City Building Inspector or Plans Examiner CITY OF TUKWIIL JAN 3 0 2017 Project Name: United Rentals PERMIT CENTER Project Address: 17700 W Valley HM Contact Person: Matt Hanes Phone Number: 206-450-9375 Summary of Revision: Sheet Number(s): M0.00 and M2.01 "Cloud" or highlight all areas of revision including ate of r .sion r/ Received at the City of Tukwila Permit Center by"VI1-4 ❑ Entered in TRAMT on \applications\formsapplications on lineVevision submittal Created: 8-13-2004 Revised: HERMANSON COMPANY LLP Home Dspanol Contact Safety & Health Claims & Insurance Washington State Department of Labor & Industries HERMANSON COMPANY LLP Owner or tradesperson Principals NICOLAISEN, KNUT H, PARTNER/MEMBER BROCK, DANIEL L, PARTNER/MEMBER FOX, DEAN M, PARTNER/MEMBER HENGEL, STEPHEN A, PARTNER/MEMBER DYCKMAN,KENNETH A, PARTNER/MEMBER ROBINETT, PAUL J, PARTNER/MEMBER HERMANSON, RICHARD L, PARTNER/MEMBER ALMON, KEVIN, PARTNER/MEMBER (End: 08/05/2010) MACDONALD, JAMES, PARTNER/MEMBER (End: 08/05/2010) Doing business as HERMANSON COMPANY LLP 1221 2ND AVE N KENT, WA 98032-2945 206-575.9700 KING County WA UBI No. Business type 602 004 844 Limited Liability Partnership Governing persons CORP HERMANSON LLC HERMANSON GROUP; License Page 1 of 3 Search L&1 A -C Index Help M.V U,I Workplace Rights Trades & Licensing Verify the contractor's active registration / license / certification (depending on trade) and any past violations. o ....................Construction.............Contract........................r. Active. Meets current requirements. License specialties GENERAL License no. HERMACL00513J Effective — expiration 01/11/2000— 08/25/2018 Bond ............ WESTERN SURETY CO $12,000.00 Bond account no. 929381801 Received by L&I Effective date 12/01/2005 01/01/2006 Expiration date Until Canceled Help us improve https:Hsecure.Ini.wa.gov/verify/Detail.aspx?UBI=602004844&LIC=HERMACL005BJ&SAW= 2/8/2017 HERMANSON COMPANY LLP Insurance Valley Forge Ins Co $1,000,000.00 Policy no. 6043050846 Received by L&I Effective date 08/15/2016 08/21/2016 Expiration date 08/21/2017 Insurance history Saving .No savings accounts during the previous 6 year period. Lawsuits against the bond or savings No lawsuits against the bond .or sa.Angs accounts during the previous 6 year period. L&I Tax debts No L&t tax debts are recorded for this contractor license during the previous 6 year period, but some debts may be recorded by other agencies. License Violations ........................................... No license violations during the previous 6 year period. Workers' comp Do you know if the business has employees? If so, verify the business is up-to-date on workers' comp premiums. L&I Account ID Account is current. 409,648.01 Doing business as HERMANSON COMPANY LLP Estimated workers reported Quarter 4 of Year 2016 "Greater than 100 Workers" L&I account representative T1 / NIKKI BUTLER (360)902-4918 - Email: BUT0235@lni.wa.gov Workplace safety and health Check for any past safety and health violations found on jobsites this business was responsible for Inspection results date 02/23/2016 No violations Inspection no. 317939295 Location 15580 NE 31st St. Redmond, WA 98052 Inspection results date 05/21/2015 Inspection no. 317935231 Location 4480 154th PI NE Redmond, WA 98052 No violations Inspection results date 12/10/2014 No violations Inspection no. 317424935 Location 21601 76th Ave W. Edmonds, WA 98026 Inspection results date 05/17/2013 Violations Page 2 of 3 Help us improve https:Hsecure.Ini.wa.gov/verify/Detail.aspx?UBI=602004844&LIC=HERMACL005BJ&SAW= 2/8/2017 A AMPS IBC INTERNATIONAL BUILDING CODE AC AIR CONDITIONING ICW INDUSTRIAL COLD WATER ACH AIR CHANGES PER HOUR ID INSIDE DIAMETER/DIMENSION ACT ACOUSTICAL CEILING TILE IE INVERT ELEVATION AD ACCESS DOOR IEER INTEGRATED ENERGY EFFICIENCY RATIO ADD'L ADDITIONAL IMC INTERNATIONAL MECHANICAL CODE AFF ABOVE FINISHED FLOOR IN INCHES AFG ABOVE FINISHED GRADE IN WG INCHES WATER GAUGE AHU AIR HANDLING UNIT IPLV INTEGRATED PART LOAD VALUE ALUM ALUMINUM KW KILOWATTS AMP/AMPS AMPERAGE LAT LEAVING AIR TEMPERATURE AP ACCESS PANEL LB/LBS POUND/POUNDS ARCH ARCHITECT LF/LIN FT LINEAL FOOT/FEET BC BEADED COLLAR LPG LIQUID PROPANE GAS BDD BACKDRAFT DAMPER LPS LOW PRESSURE STEAM BF BELOW FLOOR LVG LEAVING BHP BRAKE HORSEPOWER LWA SOUND POWER RATING LEVEL (IN DB) BLDG BUILDING LWG LOW WALL GRILLE BOD BOTTOM OF DUCT LWT LEAVING WATER TEMPERATURE BOP BOTTOM OF PIPE MAX MAXIMUM BOT BOTTOM MAU MAKE UP AIR UNIT BS BIRD SCREEN / BLACK STEEL MBH 1000 BRITISH THERMAL UNITS/HOUR BTU BRITISH THERMAL UNIT MCA MINIMUM CIRCUIT AMPACITY BTUH BRITISH THERMAL UNITS PER HOUR MD MOTORIZED DAMPER CAP CAPACITY MFR MANUFACTURER CBD CALIBRATED BALANCING DAMPER MISC MISCELLANEOUS CC CONTROLS CONTRACTOR MIN MINIMUM/MINUTE CD CEILING DIFFUSER/CONDENSATE DRAIN MPS MEDIUM PRESSURE STEAM CDWR CONDENSER WATER RETURN MT MOUNT CDWS CONDENSER WATER SUPPLY MTD MOUNTED CFM CUBIC FEET PER MINUTE MUW MAKE-UP WATER CHWR CHILLED WATER RETURN NA NOT APPLICABLE CHWS CHILLED WATER SUPPLY NC NORMALLY CLOSED/NOISE CRITERIA CLG CEILING NG/NGAS NATURAL GAS COL COLUMN NIC NOT IN CONTRACT CONC CONCRETE NO NORMALLY OPEN/NUMBER COND CONDENSATE NPW NON -POTABLE WATER CONN CONNECT/CONNECTED/CONNECTION N -R NON-RESIDENTIAL CONT CONTINUOUS/CONTINUATION OA/OSA OUTSIDE AIR CONTR CONTRACTOR OBD OPPOSED BLADE DAMPER COORD COORDINATE OD OUTSIDE DIAMETER/DIMENSION COP COEFFICIENT OF PERFORMANCE PCF POUNDS PER CUBIC FOOT CT COOLING TOWER PD PRESSURE DROP CU CUBIC/CONDENSER UNIT PH PHASE CW DOMESTIC COLD WATER/CONDENSER WATER POC POINT OF CONNECTION DB DUCTBOARD/DRY BULB/DECIBEL P/PRESS PRESSURE DDC DIRECT DIGITAL CONTROL PSI POUNDS PER SQUARE INCH DEFL DEFLECTION PSIG POUNDS PER SQUARE INCH GAUGE DEG DEGREE/DEGREES QTY QUANITY DIA DIAMETER R RETURN GRILLE/RELOCATED/RETURN DMPR DAMPER RA RETURN AIR DN DOWN RD/RND ROUND DOAS DEDICATED OUTSIDE AIR SYSTEM REF REFERENCE DWG DRAWING REQ REQUIRED EXH EXHAUST RESID RESIDENTIAL EA EACH RF RELIEF EAT ENTERING AIR TEMPERATURE RG REFRIGERANT DISCHARGE GAS EC EGGCRATE GRILLE/END CAP/ELEC CONTRACTOR RL REFRIGERANT LIQUID EER ENERGY EFFICIENT RATING RPM REVOLUTIONS PER MINUTE EF EXHAUST FAN RS REFRIGERANT SUCTION EFF EFFICIENCY S SUPPLY EL ELEVATION SA SUPPLY AIR ELEC/ELECT ELECTRICAL/ELECTRIC SAT SATURATION/SUPPLY AIR TEMPERATURE EMCS ENERGY MANAGEMENT CONTROL SYSTEM SD SMOKE DETECTOR ENT ENTERING S/D SLIP & DRIVE CONNECTION EQUIP EQUIPMENT S_C SEATTLE ____ CODE ESP EXTERNAL STATIC PRESSURE SEER SEASONAL ENERGY EFFICIENCY RATING EWT ENTERING WATER TEMPERATURE SENS SENSIBLE EXIST EXISTING SL SOUND LINED EXH EXHAUST SM SHEETMETAL F FAHRENHEIT SPEC SPECIFICATION FAC FIRE ALARM CONTRACTOR SO SCREENED OPENING FD FIRE DAMPER SOG SLAB ON GRADE FDC FIRE DEPARTMENT CONNECTION SP STATIC PRESSURE FF FINISHED FLOOR SF SQUARE FEET FIC FURNISHED AND INSTALLED BY CONTRACTOR SS STAINLESS STEEL FIO FURNISHED AND INSTALLED BY OWNER STRUC STRUCTURAL FLA FULL LOAD AMPS TA TRANSFER AIR FLEX FLEXIBLE TEMP TEMPERATURE/TEMPORARY FLR FLOOR TBD TO BE DETERMINED FOB FLAT ON BOTTOM TOD TOP OF DUCT FOIC FURNISHED BY OTHERS, TOS TOP OF STEEL/TOP OF SLAB INSTALLED BY CONTRACTOR TOT TOTAL FOS FLAT ON SIDE TSP TOTAL STATIC PRESSURE FOT FLAT ON TOP TSTAT THERMOSTAT FP FIRE PROTECTION TYP TYPICAL FPM FEET PER MINUTE UH UNIT HEATER FSD FIRE/SMOKE DAMPER UNO UNLESS NOTED OTHERWISE FT FOOT/FEET V VOLT FUT FUTURE VD VOLUME DAMPER FV FACE VELOCITY VEL VELOCITY G GRILLE VERT VERTICAL GA GAUGE/GALLON VFD VARIABLE FREQUENCY DRIVE GALV GALVANIZED VOL VOLUME GC GENERAL CONTRACTOR W WRAPPED DUCT GPM GALLONS PER MINUTE WB WET BULB GRD GRILLE/REGISTER/DIFFUSER WG WATER GAUGE GWB GYPSUM WALL BOARD W/ WITH HD HEAD W/0 WITHOUT HORIZ HORIZONTAL W/SF WATTS PER SQUARE FOOT HP HORSEPOWER WSEC WASHINGTON STATE ENERGY CODE HR HOUR HSPF HEATING SEASONAL PERFORMANCE FACTOR HT HEIGHT HWTG HIGH WALL TRANSFER GRILLE HWR HOT WATER RETURN HWS HOT WATER SUPPLY HX HEAT EXCHANGER HZ HERTZ MECHANICAL LEGEND 10X10 10X`1®1 10X10 10X10 �1�1 10X10 10X`�l 10X10 1oX�- 10 100 100 100 12X100 12X100; E10 � 100 100 100 100 -3:2 100 t 10:�: DD -A RECT SUPPLY AIR DUCT UP/TOWARD RECT SUPPLY AIR DUCT DN/AWAY RECT EXHAUST OR RETURN DUCT UP/TOWARD RECT EXHAUST OR RETURN DUCT DN/AWAY ROUND DUCT - UP/TOWARD ROUND DUCT - DN/ AWAY MECHANICAL GENERAL NOTES 1. WORK SHALL CONFORM TO APPLICABLE CODES AND REGULATIONS, INCLUDING, BUT NOT LIMITED TO THE 2015 IBC, 2015 WSEC, & 2015 IMC. WITH WASHINGTON STATE AMENDMENTS 2. DO NOT SCALE DRAWINGS, DIMENSIONS GOVERN. DIMENSIONS ARE TO FACE OF STUD, CONCRETE, OR MASONRY UNO. 3. LOCATION AND DETAILS OF EQUIPMENT, DUCT ROUTING, AND CONNECTIONS ARE APPROXIMATE. COORDINATE FINAL LOCATIONS WITH OTHER TRADES. INSTALL IN ACCORDANCE WITH APPROVED SUBMITTALS AND DETAIL DRAWINGS WHEN APPLICABLE. 4. VERIFY EXISTING CONDITIONS, DIMENSIONS, DETAILS, ETC. NOTIFY ENGINEER OF ANY DISCREPANCIES PRIOR TO PROCEEDING WITH WORK. 5. WHEN CONSTRUCTION DETAILS ARE NOT SHOWN OR NOTED FOR ANY PART OF THE WORK, DETAILS SHALL BE THE SAME AS FOR OTHER SIMILAR WORK. IF ADDITIONAL QUESTIONS REMAIN, CONTACT THE ENGINEER PRIOR TO PROCEEDING. 6. ALL STRUCTURAL OPENINGS AND PLATFORMS SHALL BE PROVIDED BY THE GENERAL CONTRACTOR UNO. 7. DUCT SEALING AND CONSTRUCTION TO MEET SMACNA AND ENERGY CODE REQUIREMENTS. UNLESS OTHERWISE NOTED, LOW PRESSURE DUCTWORK SEAL CLASS C.OF VAV MEDIIUMBPRESSURE CONSTANT DUCTW RK (UPSTREAM OF SYSTEMS, ILET BOXES,HH GHSVELOCIlYTEXHAUSTS, MEET 2" CONSTRUCTION STANDARDS 4" CONSTRUCTION ITH STANDARDS WITH SEAL CLASS A. DUCT RISERS IN SHAFTS WITH DAMPERED PENETRATIONS TO MEET 6" CONSTRUCTION STANDARDS WITH SEAL CLASS A. 8. ALL CEILING DIFFUSERS ARE 4 -WAY THROW UNLESS NOTED OTHERWISE. 9. ALL DUCT DIMENSIONS ARE OUTSIDE DIMENSIONS BEFORE SOUND LINING HAS BEEN ACCOUNTED FOR (SOUND LINING @ 1", UNO) FLATOVAL DUCT - UP/ TOWARD 10. OUTSIDE AIR INTAKES ON ALL AIR HANDLING UNITS SHALL BE 10 FEET AWAY FROM ANY VENTS, STREETS, LOADING DOCK, FLATOVAL DUCT - DN/ AWAY NEIGHBORING LOT LINES & FUEL BURNING EQUIPMENT OR 3 FEET BELOW OR 25 ABOVE ANY CONTAMINANT SOURCE WITHIN 10 FEET. 11. ALL AIR ECONOMIZERS SHALL BE CAPABLE OF THE FOLLOWING PER C403.3.1 & C403.2.4.7: -0% TO 100% OF THE DESIGN SUPPLY AIR WITH FAULT DETECTION & DIAGNOSTIC REPORTING. DUCT OVERLAP -CONTROLLED BY A CONTROL SYSTEM DETERMINING IF THE OUTSIDE AIR CAN MEET PART OR ALL OF THE BUILDING COOLING LOADS. -INTEGRATED TO PROVIDE PARTIAL COOLING EVEN WHEN MECHANICAL COOLING IS REQUIRED. BOOT TAP 45' TAP VOLUME DAMPER CALIBRATED BALANCING DAMPER RISER) & DROP(D) TRANSITION TURNING VANES/SPLITTERS DUCT MOUNTED SMOKE DETECTOR BACK DRAFT DAMPER FLEXIBLE DUCT AIR FLOW (FORCED AIR) COMBINATION FSD FIRE DAMPER SMOKE DAMPER MOTOR OPERATED DAMPER y w 0 ACCESS DOORS SOUND TRAP FLEX CONNECTION 16X160DSL ACOUSTICALLY LINED DUCT OD = OUTSIDE DIMENSIONS SL = SOUND LINING (THICKNESS) 1 Q99 � FABRIC DUCT ® CLEARANCE ® SUPPLY AIR DIFFUSER (WITH CORE BLANKOFF) CEILING RETURN, TRANSFER OR EXHAUST AIR GRILLE o SLOTTED DIFFUSER (PLAN VIEW) C3A REVISION CLOUD & TRIANGLE ##0 ROUND DUCT SYMBOL ##X## 0 FLATOVAL DUCT SYMBOL ##° DEGREES SYMBOL ® POINT OF CONNECTION CD1-100 GRD TAG IDENTIFIER = TYPE -CFM 80 SIZE 0 T'STAT/TEMP SENSOR 1 0� CARBON DIOXIDE HUMIDITY SENSOR SENSOR sD SMOKE DETECTOR Co CARBON MONOXIDE sP STATIC PRESSURE SENSOR SENSOR 12. OUTSIDE AIR INTAKE, RELIEF, AND EXHAUST OPENINGS SHALL BE CLASS 1 AND EQUIPPED WITH MOTORIZED (OR GRAVITY PER EXCEPTIONS IN C403.2.4.3) DAMPERS WHICH CLOSE AUTOMATICALLY WHEN SYSTEM IS OFF OR UPON POWER FAILURE, UNO FOR SMOKE CONTROL SYSTEM OPERATION 13. THE CONTROL SYSTEM SHALL MEET C403 AND BE PROGRAMMABLE, CAPABLE OF BEING SET FOR DIFFERENT DAY TYPES PER WEEK, DEADBAND SETTING OF AT LEAST 5F (10T FOR RESIDENTIAL BETWEEN THE HEATING AND COOLING SETPOINTS AND SETBACK TEMPERATURES WITH OPTIMAL START CONTROL. CONTROL SYSTEM SHALL INCLUDE A MICROPROCESSOR AND BE CAPABLE OF VARYING FLOWS AND RESETTING SUPPLY AIR & WATER TEMPERATURES BY REPRESENTATIVE BUILDING LOADS WHERE REQUIRED IN C403.4. 14. WHERE REQUIRED BY C408, RECORD DRAWINGS OF THE ACTUAL INSTALLATION SHALL BE PROVIDED TO THE BUILDING OWNER WITHIN 90 DAYS OF THE DATE OF SYSTEM ACCEPTANCE PER THE ENERGY CODE. AN OPERATING MANUAL AND MAINTENANCE MANUAL SHALL BE PROVIDED TO THE BUILDING OWNER. ALL HVAC SYSTEMS SHALL BE BALANCED AND A WRITTEN BALANCING REPORT SHALL BE PROVIDED TO THE OWNER. HVAC CONTROL SYSTEMS SHALL BE TESTED TO ENSURE THAT THEY OPERATE IN ACCORDANCE WITH APPROVED PLANS. A PRELIMINARY COMMISSIONING REPORT OF TEST PROCEDURES AND RESULTS SHALL BE PREPARED PRIOR TO ISSUANCE OF A FINAL CERTIFICATE OF OCCUPANCY. A COMPLETE FINAL COMMISSIONING REPORT OF TEST PROCEDURES AND RESULTS SHALL BE PROVIDED TO THE OWNER. 15. MECHANICAL SYSTEMS SHALL COMPLY WITH SEISMIC RESTRAINT REQUIREMENTS OF THE BUILDING CODE, SMACNA AND ASCE 7. ALL LIFE SAFETY OR HAZARDOUS MATERIAL RELATED SYSTEMS SHALL BE DEEMED AN Ip=1.5 FOR RESTRAINT METHODS OR AS NOTED ON THE DRAWINGS. REFER TO CODES FOR INSTALLATION REQUIREMENTS AND EXCEPTIONS BASED ON SIZING, WEIGHTS AND MOUNTING HEIGHTS. 16. PROVIDE EARTHQUAKE RESTRAINTS FOR HVAC EQUIPMENT AS REQUIRED BY SMACNA SEISMIC RESTRAINT MANUAL, SEISMIC HAZARD B. WIRES FOR CEILING SYSTEM ETC. SHALL NOT BE HUNG OFF HVAC EQUIPMENT OR HVAC EQUIPMENT SUPPORTS. 17. PROVIDE FIRE AND COMBINATION FIRE/SMOKE DAMPERS WHERE SHOWN ON PLANS AND WHERE REQUIRED PER CODE. 18. ALL PIPING PENETRATIONS THROUGH RATED ASSEMBLIES SHALL BE SEALED WITH AN UL APPROVED FIRE CAULKING. 19. SMOKE DETECTORS PROVIDING AUTOMATIC SHUTDOWN SHALL BE PROVIDED FOR HVAC EQUIPMENT DELIVERING >2000 CFM (INCLUDING MULTIPLE UNITS DUCTED INTO COMMON DISTRIBUTION OR RETURN, WITH A TOTAL SUPPLY >2000 CFM) OR EACH STORY OF RETURN SYSTEMS OVER 15,000 CFM IN A MULTI -STORY INSTALLATION, PER CODE. SMOKE DETECTORS SHALL BE FIC (ELEC) UNO. POWER -WIRING AND INTERLOCK TO FIRE ALARM SYSTEM BY ELECTRICAL CONTRACTOR AS APPLICABLE. VAV BOX (WITH FAN) SHUTDOWN CAN BE THROUGH CONTROLS SYSTEM. 20. MECHANICAL ACCESS PANELS SI-IALL BE PROVIDED BY MECHANICAL CONTRACTOR AND INSTALLED BY GENERAL CONTRACTOR. 21. ALL MOTOR STARTERS NOT SHOWN IN EQUIPMENT SCHEDULES SHALL BE FURNISHED AND INSTALLED BY ELECTRICAL CONTRACTOR. MOTOR EFFICIENCIES TO MEET OR EXCEED CODE MINIMUM. 22. FOR ALL "SEALED AIR TIGHT" OR PRESSURIZED SHAFTS/ROOMS, THE FOLLOWING SHALL OCCUR: -ALL VERTICAL JOINTS & CORNERS SHALL BE PROVIDED WITH A CONTINUOUS SEAL FOR THE LENGTH OF THE JOINT (BY GC). -TOP AND BOTTOM WALL TRACKS SHOULD BE CAULKED ALONG THEIR ENTIRE LENGTH (BY GC). -ANY FLOOR DECKING PERPENDICULAR TO THE CONSTRUCTION SHALL BE CAULKED (BY GC). FILLING WITH ROCK WOOL IS NOT ACCEPTABLE. -ANY PENETRATIONS OF THE CONSTRUCTION (DUCTWORK CONDUIT PIPING ...) SHALL BE SEALED ON BOTH SIDES -ALL DOORS SHALL BE PROVIDED WITH TIGHT FITTING GASKETS MD THRESHOLD SWEEPS, AND OPEN AGAINST THE DIRECTION OF PRESSURE. -USE SECTION 909.5 OF THE 2012 IBC FOR MAX ALLOWABLE LEAKAGE AREA, FOLLOWING THE GUIDELINES FOR TIGHT STAIR SHAFT CONSTRUCTION. 23. ALL ADHESIVES, SEALANTS, PAINTS AND COATINGS USED DURING THE INSTALLATION/FINISH WORK SHALL MEET THE LEED REQUIREMENTS FOR IEQ. 24. MAXIMUM STANDARD LENGTH OF FLEXIBLE DUCT SHALL BE 12 FEET; UP TO 25' MAXIMUM LENGTH IS ACCEPTABLE IF; REFER TOT INSTALLATION TESTED FOR 'SUPPORTOREWREMENTS D FLEX BLE DUCTS FLAMEBSPREADMRATING I SHALLBBE D< 250 ANDD SMOKED DEVELOPEDRATING SHALL BE < 50. USE THERMAFLEX MODEL G -KM FOR LOW AND MEDIUM PRESSURE APPLICATIONS OR APPROVED EQUAL. 25. ELECTRICAL METERING OF SYSTEMS AS REQUIRED BY ENERGY CODE SECTION C409 IS BY ELECTRICAL. THE ELECTRICAL DESIGN & CONTRACTOR TEAM WILL FURNISH THE NECESSARY ELECTRICAL DISTRIBUTION AND METERING COMPONENTS - SEE ELECTRICAL DRAWINGS. THE MECHANICAL CONTRACTOR WILL FURNISH A BUILDING MANAGEMENT SYSTEM CAPABLE OF COLLECTING AND STORING THE INFORMATION WITH A VISIBLE DISPLAY/NOTIFICATION READILY ACCESSIBLE TO OPERATION AND MANAGEMENT PERSONNEL AS REQUIRED. EXISTING DUCTWORK UPDATED DEMO DUCTWORK I WALL -MOUNTED GRILLE oo PIPE ELBOW UP SUPPLY & RETURN PIPE ELBOW DN R-8 DIRECTION OF FLOW -" DIRECTION OF SLOPE DOWN 7 PLUG OR CAP SUPPLY & RETURN PRESS REDUCING ASSEMBLY ---��--� SOLENOID VALVE SUPPLY AIR <550 OR >1050 PUMP Z--CHWS /CHWR-s CHILLED WATER SUPPLY/RETURN t-- RL/RS -s REFRIGERANT LIQUID/SUCTION r- NG -i NATURAL GAS 2- LPG -s LIQUID PROPANE GAS Z-CDWS /CDWR-s CONDENSER WATER SUPPLY/RET 2-HWS/HWR-s HEATING WATER SUPPLY/RETURN 2- COND -S CONDENSATE r- FOV --s FUEL OIL VENT 2- FOS / FOR --s FUEL OIL SUPPLY/RETURN z RDG REFRIGERANT DISCHARGE GAS 12. OUTSIDE AIR INTAKE, RELIEF, AND EXHAUST OPENINGS SHALL BE CLASS 1 AND EQUIPPED WITH MOTORIZED (OR GRAVITY PER EXCEPTIONS IN C403.2.4.3) DAMPERS WHICH CLOSE AUTOMATICALLY WHEN SYSTEM IS OFF OR UPON POWER FAILURE, UNO FOR SMOKE CONTROL SYSTEM OPERATION 13. THE CONTROL SYSTEM SHALL MEET C403 AND BE PROGRAMMABLE, CAPABLE OF BEING SET FOR DIFFERENT DAY TYPES PER WEEK, DEADBAND SETTING OF AT LEAST 5F (10T FOR RESIDENTIAL BETWEEN THE HEATING AND COOLING SETPOINTS AND SETBACK TEMPERATURES WITH OPTIMAL START CONTROL. CONTROL SYSTEM SHALL INCLUDE A MICROPROCESSOR AND BE CAPABLE OF VARYING FLOWS AND RESETTING SUPPLY AIR & WATER TEMPERATURES BY REPRESENTATIVE BUILDING LOADS WHERE REQUIRED IN C403.4. 14. WHERE REQUIRED BY C408, RECORD DRAWINGS OF THE ACTUAL INSTALLATION SHALL BE PROVIDED TO THE BUILDING OWNER WITHIN 90 DAYS OF THE DATE OF SYSTEM ACCEPTANCE PER THE ENERGY CODE. AN OPERATING MANUAL AND MAINTENANCE MANUAL SHALL BE PROVIDED TO THE BUILDING OWNER. ALL HVAC SYSTEMS SHALL BE BALANCED AND A WRITTEN BALANCING REPORT SHALL BE PROVIDED TO THE OWNER. HVAC CONTROL SYSTEMS SHALL BE TESTED TO ENSURE THAT THEY OPERATE IN ACCORDANCE WITH APPROVED PLANS. A PRELIMINARY COMMISSIONING REPORT OF TEST PROCEDURES AND RESULTS SHALL BE PREPARED PRIOR TO ISSUANCE OF A FINAL CERTIFICATE OF OCCUPANCY. A COMPLETE FINAL COMMISSIONING REPORT OF TEST PROCEDURES AND RESULTS SHALL BE PROVIDED TO THE OWNER. 15. MECHANICAL SYSTEMS SHALL COMPLY WITH SEISMIC RESTRAINT REQUIREMENTS OF THE BUILDING CODE, SMACNA AND ASCE 7. ALL LIFE SAFETY OR HAZARDOUS MATERIAL RELATED SYSTEMS SHALL BE DEEMED AN Ip=1.5 FOR RESTRAINT METHODS OR AS NOTED ON THE DRAWINGS. REFER TO CODES FOR INSTALLATION REQUIREMENTS AND EXCEPTIONS BASED ON SIZING, WEIGHTS AND MOUNTING HEIGHTS. 16. PROVIDE EARTHQUAKE RESTRAINTS FOR HVAC EQUIPMENT AS REQUIRED BY SMACNA SEISMIC RESTRAINT MANUAL, SEISMIC HAZARD B. WIRES FOR CEILING SYSTEM ETC. SHALL NOT BE HUNG OFF HVAC EQUIPMENT OR HVAC EQUIPMENT SUPPORTS. 17. PROVIDE FIRE AND COMBINATION FIRE/SMOKE DAMPERS WHERE SHOWN ON PLANS AND WHERE REQUIRED PER CODE. 18. ALL PIPING PENETRATIONS THROUGH RATED ASSEMBLIES SHALL BE SEALED WITH AN UL APPROVED FIRE CAULKING. 19. SMOKE DETECTORS PROVIDING AUTOMATIC SHUTDOWN SHALL BE PROVIDED FOR HVAC EQUIPMENT DELIVERING >2000 CFM (INCLUDING MULTIPLE UNITS DUCTED INTO COMMON DISTRIBUTION OR RETURN, WITH A TOTAL SUPPLY >2000 CFM) OR EACH STORY OF RETURN SYSTEMS OVER 15,000 CFM IN A MULTI -STORY INSTALLATION, PER CODE. SMOKE DETECTORS SHALL BE FIC (ELEC) UNO. POWER -WIRING AND INTERLOCK TO FIRE ALARM SYSTEM BY ELECTRICAL CONTRACTOR AS APPLICABLE. VAV BOX (WITH FAN) SHUTDOWN CAN BE THROUGH CONTROLS SYSTEM. 20. MECHANICAL ACCESS PANELS SI-IALL BE PROVIDED BY MECHANICAL CONTRACTOR AND INSTALLED BY GENERAL CONTRACTOR. 21. ALL MOTOR STARTERS NOT SHOWN IN EQUIPMENT SCHEDULES SHALL BE FURNISHED AND INSTALLED BY ELECTRICAL CONTRACTOR. MOTOR EFFICIENCIES TO MEET OR EXCEED CODE MINIMUM. 22. FOR ALL "SEALED AIR TIGHT" OR PRESSURIZED SHAFTS/ROOMS, THE FOLLOWING SHALL OCCUR: -ALL VERTICAL JOINTS & CORNERS SHALL BE PROVIDED WITH A CONTINUOUS SEAL FOR THE LENGTH OF THE JOINT (BY GC). -TOP AND BOTTOM WALL TRACKS SHOULD BE CAULKED ALONG THEIR ENTIRE LENGTH (BY GC). -ANY FLOOR DECKING PERPENDICULAR TO THE CONSTRUCTION SHALL BE CAULKED (BY GC). FILLING WITH ROCK WOOL IS NOT ACCEPTABLE. -ANY PENETRATIONS OF THE CONSTRUCTION (DUCTWORK CONDUIT PIPING ...) SHALL BE SEALED ON BOTH SIDES -ALL DOORS SHALL BE PROVIDED WITH TIGHT FITTING GASKETS MD THRESHOLD SWEEPS, AND OPEN AGAINST THE DIRECTION OF PRESSURE. -USE SECTION 909.5 OF THE 2012 IBC FOR MAX ALLOWABLE LEAKAGE AREA, FOLLOWING THE GUIDELINES FOR TIGHT STAIR SHAFT CONSTRUCTION. 23. ALL ADHESIVES, SEALANTS, PAINTS AND COATINGS USED DURING THE INSTALLATION/FINISH WORK SHALL MEET THE LEED REQUIREMENTS FOR IEQ. 24. MAXIMUM STANDARD LENGTH OF FLEXIBLE DUCT SHALL BE 12 FEET; UP TO 25' MAXIMUM LENGTH IS ACCEPTABLE IF; REFER TOT INSTALLATION TESTED FOR 'SUPPORTOREWREMENTS D FLEX BLE DUCTS FLAMEBSPREADMRATING I SHALLBBE D< 250 ANDD SMOKED DEVELOPEDRATING SHALL BE < 50. USE THERMAFLEX MODEL G -KM FOR LOW AND MEDIUM PRESSURE APPLICATIONS OR APPROVED EQUAL. 25. ELECTRICAL METERING OF SYSTEMS AS REQUIRED BY ENERGY CODE SECTION C409 IS BY ELECTRICAL. THE ELECTRICAL DESIGN & CONTRACTOR TEAM WILL FURNISH THE NECESSARY ELECTRICAL DISTRIBUTION AND METERING COMPONENTS - SEE ELECTRICAL DRAWINGS. THE MECHANICAL CONTRACTOR WILL FURNISH A BUILDING MANAGEMENT SYSTEM CAPABLE OF COLLECTING AND STORING THE INFORMATION WITH A VISIBLE DISPLAY/NOTIFICATION READILY ACCESSIBLE TO OPERATION AND MANAGEMENT PERSONNEL AS REQUIRED. 1 Ktf tK I U UgW.L.6 1 -UK t -UK I HtK KtC2UIKtMtN 15 & ALSU K4UJ 1 -UK KtblUtN I IAL 1Nb I ALLA I TUNS 2 INSULATED COOLED DUCTS REQUIRED A VAPOR RETARDER (PERM < 0.5) AND SEALED JOINTS 3 WEATHERPROOF BARRIER REQUIRED AROUND DUCTWORK TO MAINTAIN WATER TIGHTNESS 4 INSULATE OUTSIDE AIR DUCTS TO BUILDING EXTERIOR WALL LEVEL PER ENERGY CODE SECTION: C403.2.8.1 UNTIL CONNECTED TO EQUIPMENT SERVED OR TO THE CODE REQUIRED SHUTOFF DAMPER (AND '"THICK INSULATION MIN. TO PREVENT CONDENSATION ON DUCTS IN PLENUM UP TO THE HEATING OR COOLING EQUIPMENT) 5 R-7 CAN BE USED IN LIEU OF BUILDING ENVELOPE INSULATION LEVEL IF: DEDICATED OUTSIDE AIR SYSTEM AND <2,800 CFM SUPPLY AIR MINIMUMIPE INSULATION LAST UPDATED: 07/11/16 MINIMUMPUCT INSULATIONLAST UPDATED 07/11/16 DUCT TYPE DUCT LOCATION (IN HEATED AND MECHANICALLY COOLED DUCT SYSTEM) INSULATION R -VALUE REMARKS SUPPLY & RETURN NOT WITHIN CONDITIONED SPACE: OUTSIDE BUILDING R-8 1,2,3 OUTSIDE AIR WITHIN CONDITIONED SPACE: INSIDE BUILDING SEE NOTES 4 & 5 1,2,3,4,5 SUPPLY & RETURN NOT WITHIN CONDITIONED SPACE: INSIDE BUILDING R-6 1,2 SUPPLY AIR <550 OR >1050 WITHIN CONDITIONED SPACE R-3.3 112 1 Ktf tK I U UgW.L.6 1 -UK t -UK I HtK KtC2UIKtMtN 15 & ALSU K4UJ 1 -UK KtblUtN I IAL 1Nb I ALLA I TUNS 2 INSULATED COOLED DUCTS REQUIRED A VAPOR RETARDER (PERM < 0.5) AND SEALED JOINTS 3 WEATHERPROOF BARRIER REQUIRED AROUND DUCTWORK TO MAINTAIN WATER TIGHTNESS 4 INSULATE OUTSIDE AIR DUCTS TO BUILDING EXTERIOR WALL LEVEL PER ENERGY CODE SECTION: C403.2.8.1 UNTIL CONNECTED TO EQUIPMENT SERVED OR TO THE CODE REQUIRED SHUTOFF DAMPER (AND '"THICK INSULATION MIN. TO PREVENT CONDENSATION ON DUCTS IN PLENUM UP TO THE HEATING OR COOLING EQUIPMENT) 5 R-7 CAN BE USED IN LIEU OF BUILDING ENVELOPE INSULATION LEVEL IF: DEDICATED OUTSIDE AIR SYSTEM AND <2,800 CFM SUPPLY AIR MINIMUMIPE INSULATION LAST UPDATED: 07/11/16 FLUID DESIGN INSULATION CONDUCTIVITY NOMINAL PIPE DIAMETER (INCH) OPERATING TEMP °F CONDUCTIVITY RANGE MEAN TEMP RATING OF <1 1 TO <1-1/2 1-1/2TO <4 4 TO <8 18 HEATING SYSTEMS (STEAM, CONDENSATE, HYDRONIC HOT WATER, DOMESTIC HOT WATER & RECIRC) >350 0.32-0.34 250 4.5 5.0 5.0 5.0 5.0 251-350 0.29-0.32 200 3.0 4.0 4.5 4.5 4.5 201-250 0.27-0.30 150 2.5 2.5 2.5 3.0 3.0 141-200 0.25-0.29 125 1.5 1.5 2.0 2.0 2.0 105-140 0.21-0.28 100 1.0 1.0 1.5 1.5 1.5 DOMESTIC COLD WATER AND HORIZONTAL RAIN LEADERS TO FIRST VERTICAL RAIN LEADER (TO PREVENT CONDENSATION) N/A 1 0.21-0.27 1 75 1 0.5 1 0.5 T 0.5 F 0.5 0.5 COOLING SYSTEMS (CHILLED WATER, BRINE AND REFRIGERANT, WATERSIDE ECONOMIZER SYSTEMS)** 40-60 0.21-0.27 75 0.5 0.5 1.0 1.0 1.0 <40 0.20-0.26 75 0.5 1 1.0 1.0 1.0 1.5 NOTE: * NOT REQUIRED FOR STRAINERS, CONTROL VALVES & BALANCING VALVES ASSOCIATED WITH PIPING 1" OR LESS IN DIA. ** TYPICAL CONDENSER WATER PIPE IN NON -ECONOMIZER SYSTEMS IS NOT INSULATED SEE R403 FOR RESIDENTIAL INSTALLATIONS. DRAWING INDEX SHEET NO. SHEET TITLE CURRENT REVISION M0.00 LEGEND, ABBREVIATIONS, GENERAL NOTES, & SHEET INDEX - HVAC M2.01 PARTIAL 1ST FLOOR PLANS, ELEVATION, DETAIL & SCHEDULE - HVAC 1 3623049057 LEGAL DESCRIPTION LOT 2 OF RENTON SHORT PLAT NO 346-79 REC NO 7907169001 SD PLAT DAF -POR GL 2 & NE 1/4 OF NW 1/4 SD SEC LY ELY OF WEST VALLEY ROAD & WLY OF PSE R/W & LY NLY OF LN WCH IS 756 FT N OF MEAS AT R/A THOF & PLT N LN OF S 180 TH ST LESS POR CONV FOR SR 181 Building Today, Defining Tomorrow Hermanson Company LLP 1221 2nd Avenue North Kent, Washington 98032 Tel: (206) 575-9700 Fax: (206) 575-9800 www.hermanson.com Contractor Reg #: HERMACLO05BJ UNITED RENTAL SHOP EXHAUST FAN 17700 W. VALLEY HWY TUKWILA, WA 98188 VICINITY MAP NO SCALE SITE IAP NO SCALE EVISIONS filo Ct121nq2S Sit^!I hr, r;,,:�,Cl­� to tho ;cc>pF of work withoi.i: prior apl)ro\t,.1 of Tu!cwi!a Building Givicion !OTE: Revisicns will rccluiro a n, -,..v plan submittal and may inc,ude additional p'an rcviev° fees I RLECOPY Permit No. i' UhieCt to errori and , r Ai.lproval X91 8 f�. 't yd9 F CEtri . i i, i " L. �1 I� i the violation or � qjv s:tdopj@o, co do o. `frdlt?a�?�s of approves? �::ioid i:opy and coed-lijo3ec, i3 Date: CitY Of TuWjila BUILDING DIVISION 6010114 ; N :3 y a Oki Revisions 2L 12/09/16 JMH PERMIT CORRECTION 11/11/16 JMH ISSUE FOR PERMIT No. Date By Description Design Team Design JMH Drawn FVP Checked DTN Scale AS NOTED Drawing Number C-0674-06041 Project Number 14-16-06041 Issue Date 11/11/16 LEGEND, ABBREVIATION, GENERAL NOTES & SHEET INDEX -HVAC ❑c'?iL ;.n�;cal Ytv'r] �. Electrical i� iuinbing o R� i E C Gas Piping Ci,,j of Tukwila TR ! _k��I CrIV'ISIOv .. 'IEWED F® RECEIV UO(OCOMP LI°AP ITY' OF TU ® PROVED JAN 3 0 2047 FEB 02 X01 ERfUlfT CENTER NJ of TukWilc' C°M o� (� A ? 9 ti ^ a SITE IAP NO SCALE EVISIONS filo Ct121nq2S Sit^!I hr, r;,,:�,Cl­� to tho ;cc>pF of work withoi.i: prior apl)ro\t,.1 of Tu!cwi!a Building Givicion !OTE: Revisicns will rccluiro a n, -,..v plan submittal and may inc,ude additional p'an rcviev° fees I RLECOPY Permit No. i' UhieCt to errori and , r Ai.lproval X91 8 f�. 't yd9 F CEtri . i i, i " L. �1 I� i the violation or � qjv s:tdopj@o, co do o. `frdlt?a�?�s of approves? �::ioid i:opy and coed-lijo3ec, i3 Date: CitY Of TuWjila BUILDING DIVISION 6010114 ; N :3 y a Oki Revisions 2L 12/09/16 JMH PERMIT CORRECTION 11/11/16 JMH ISSUE FOR PERMIT No. Date By Description Design Team Design JMH Drawn FVP Checked DTN Scale AS NOTED Drawing Number C-0674-06041 Project Number 14-16-06041 Issue Date 11/11/16 LEGEND, ABBREVIATION, GENERAL NOTES & SHEET INDEX -HVAC ❑c'?iL ;.n�;cal Ytv'r] �. Electrical i� iuinbing o R� i E C Gas Piping Ci,,j of Tukwila TR ! _k��I CrIV'ISIOv .. 'IEWED F® RECEIV UO(OCOMP LI°AP ITY' OF TU ® PROVED JAN 3 0 2047 FEB 02 X01 ERfUlfT CENTER NJ of TukWilc' A" BUILDING ELEVATION SCALE; 1/4" = 1'-0" FAN SCHEDULE LAST U PDAT ED: 11/08/16 UNIT TAG LOCATION AREA SERVED BASIS OF DESIGN TYPE MOUNTING LOCATION CFM ESP IN WG MOTOR CONTROLS SYSTEM DAMPER I ELECT VPH I SOUND SONES I WEIGHT LBS REMARKS BHP HP/W EF -101 WALL SHOP GREENHECK CWB-240-15 UTIL SET WALL 6 000 0.25 1.00 1.5 ON OFF TIMERI MD 1 20811 1 15 1 375 1-7 GENERAL ALL TRADES TO CONFIRM EQUIPMENT REQUIREMENTS (ELECTRICAL, WEIGHT, SIZE, ETC...) WITH APPROVED SUBMITTALS PRIOR TO INSTALLATION; FIELD COORDINATE FINAL LOCATION & INSTALL PER MANUFACTURERS REQUIREMENTS REMARKS: 1 ELECTRICAL CONTRACTOR TO PROVIDE SCCR PROTECTION FOR EQUIPMENT AS REQUIRED BY NATIONAL ELECTRICAL CODE. MANUFACTURER TO PROVIDE SCCR LISTING (5 KAIC MINIMUM) INSIDE CONTROL PANEL AS REQUIRED BY NATIONAL ELECTRICAL CODE. 2 ELECTRICAL DISCONNECT AND MOTOR STARTER (AS REQUIRED) BY ELECTRICAL CONTRACTOR 3 CONTROLLED VIA TIMER (PROVIDED AND INSTALLED WITH FAN) 4 PROVIDE WITH GALVANIZED BIRDSCREEN 5 MOTORIZED DAMPER (LINE VOLTAGE, INTERLOCKED WITH FAN OPERATION) 6 PROVIDE WITH SMARTSTART MSAC MOTOR STARTER IN A NEMA -1 ENCLOSURE 7 INTERLOCK OPERATION WITH ROLL UP DOOR SUCH THAT THE FAN WILL NOT OPERATE WHEN DOOR IS CLOSED. LE EXTERIOR WALL ve . WELDED STEEL ANGLE FRAME 3/8" NEOPRENE SECURED TO FAN HOUSING AND VIBRATION ISOLATION PAD ° d CONCRETE WALL WITH LAG (TYP ALL FOUR SIDES) ° BOLTS/EXPANSION ANCHORS d ° i MOTORIZED DAMPER EF'101 CONNECT TO PROPERLY --� SUPPORTED AND BRACED EXHAUST DUCT DAMPER MOTOR (ACCESS REQ'D) nw 20X20 THRU WALL °d F UPBLAST EXHAUST FAN, SEE SCHEDULE � BIRDGAURD WITHIN 41 FAN CONE NEMA 3R WEATHERPROOF DISCONNECT (E.C.) NOTE: AIR FLOW DIRECTION AND FAN CONFIGURATION SHALL BE AS SHOWN ON PLANS. 1 1:) WALL MOUNTED EXHAUST FAN DETAIL M� NOT TO SCALE 18" MINIMUM MAKEUP AIR OPENING PLACE INTERLOCK SENSOR AT 18" 1.1 ROLL—UP GARAGE DOOR 9 EXTERIOR ELEVATION SCALE: 1/4" = 1'-0" MAKE UP AIR CALCULATION 12/9/2016 Volume of air=6000 cfm 6000 cfm Max desired velocity=500 fpm 500 fpm = 12 square feet Minimum open'ng required= 12 square feet a 15' 25' n GRADE ISSUE FOR PERMIT ,i a 15' 25' n GRADE ISSUE FOR PERMIT A AMPS IBC INTERNATIONAL BUILDING CODE AC AIR CONDITIONING ICW INDUSTRIAL COLD WATER ACH AIR CHANGES PER HOUR ID INSIDE DIAMETER/DIMENSION ACT ACOUSTICAL CEILING TILE IE INVERT ELEVATION AD ACCESS DOOR IEER INTEGRATED ENERGY EFFICIENCY RATIO ADD'L ADDITIONAL IMC INTERNATIONAL MECHANICAL CODE AFF ABOVE FINISHED FLOOR IN INCHES AFG ABOVE FINISHED GRADE IN WG INCHES WATER GAUGE AHU AIR HANDLING UNIT IPLV INTEGRATED PART LOAD VALUE ALUM ALUMINUM KW KILOWATTS AMP/AMPS AMPERAGE LAT LEAVING AIR TEMPERATURE AP ACCESS PANEL LB/LBS POUND/POUNDS ARCH ARCHITECT LF/LIN FT LINEAL FOOT/FEET BC BEADED COLLAR LPG LIQUID PROPANE GAS BDD BACKDRAFT DAMPER LPS LOW PRESSURE STEAM BF BELOW FLOOR LVG LEAVING BHP BRAKE HORSEPOWER LWA SOUND POWER RATING LEVEL (IN DB) BLDG BUILDING LWG LOW WALL GRILLE BOD BOTTOM OF DUCT LWT LEAVING WATER TEMPERATURE BOP BOTTOM OF PIPE MAX MAXIMUM BOT BOTTOM MAU MAKE UP AIR UNIT BS BIRD SCREEN / BLACK STEEL MBH 1000 BRITISH THERMAL UNITS/HOUR BTU BRITISH THERMAL UNIT MCA MINIMUM CIRCUIT AMPACITY BTUH BRITISH THERMAL UNITS PER HOUR MD MOTORIZED DAMPER CAP CAPACITY MFR MANUFACTURER CBD CALIBRATED BALANCING DAMPER MISC MISCELLANEOUS CC CONTROLS CONTRACTOR MIN MINIMUM/MINUTE CD CEILING DIFFUSER/CONDENSATE DRAIN MPS MEDIUM PRESSURE STEAM CDWR CONDENSER WATER RETURN MT MOUNT CDWS CONDENSER WATER SUPPLY MTD MOUNTED CFM CUBIC FEET PER MINUTE MUW MAKE-UP WATER CHWR CHILLED WATER RETURN NA NOT APPLICABLE CHWS CHILLED WATER SUPPLY NC NORMALLY CLOSED/NOISE CRITERIA CLG CEILING NG/NGAS NATURAL GAS COL COLUMN NIC NOT IN CONTRACT CONC CONCRETE NO NORMALLY OPEN/NUMBER COND CONDENSATE NPW NON -POTABLE WATER CONN CONNECT/CONNECTED/CONNECTION N -R NON-RESIDENTIAL CONT CONTINUOUS/CONTINUATION OA/OSA OUTSIDE AIR CONTR CONTRACTOR OBD OPPOSED BLADE DAMPER COORD COORDINATE OD OUTSIDE DIAMETER/DIMENSION COP COEFFICIENT OF PERFORMANCE PCF POUNDS PER CUBIC FOOT CT COOLING TOWER PD PRESSURE DROP CU CUBIC/CONDENSER UNIT PH PHASE CW DOMESTIC COLD WATER/CONDENSER WATER POC POINT OF CONNECTION DB DUCTBOARD/DRY BULB/DECIBEL P/PRESS PRESSURE DDC DIRECT DIGITAL CONTROL PSI POUNDS PER SQUARE INCH DEFL DEFLECTION PSIG POUNDS PER SQUARE INCH GAUGE DEG DEGREE/DEGREES QTY QUANITY DIA DIAMETER R RETURN GRILLE/RELOCATED/RETURN DMPR DAMPER RA RETURN AIR DN DOWN RD/RND ROUND DOAS DEDICATED OUTSIDE AIR SYSTEM REF REFERENCE DWG DRAWING REQ REQUIRED EXH EXHAUST RESID RESIDENTIAL EA EACH RF RELIEF EAT ENTERING AIR TEMPERATURE RG REFRIGERANT DISCHARGE GAS EC EGGCRATE GRILLE/END CAP/ELEC CONTRACTOR RL REFRIGERANT LIQUID EER ENERGY EFFICIENT RATING RPM REVOLUTIONS PER MINUTE EF EXHAUST FAN RS REFRIGERANT SUCTION EFF EFFICIENCY S SUPPLY EL ELEVATION SA SUPPLY AIR ELEC/ELECT ELECTRICAL/ELECTRIC SAT SATURATION/SUPPLY AIR TEMPERATURE EMCS ENERGY MANAGEMENT CONTROL SYSTEM SD SMOKE DETECTOR ENT ENTERING S/D SLIP & DRIVE CONNECTION EQUIP EQUIPMENT S_C SEATTLE ____ CODE ESP EXTERNAL STATIC PRESSURE SEER SEASONAL ENERGY EFFICIENCY RATING EWT ENTERING WATER TEMPERATURE SENS SENSIBLE EXIST EXISTING SL SOUND LINED EXH EXHAUST SM SHEETMETAL F FAHRENHEIT SPEC SPECIFICATION FAC FIRE ALARM CONTRACTOR SO SCREENED OPENING FD FIRE DAMPER SOG SLAB ON GRADE FDC FIRE DEPARTMENT CONNECTION SP STATIC PRESSURE FF FINISHED FLOOR SF SQUARE FEET FIC FURNISHED AND INSTALLED BY CONTRACTOR SS STAINLESS STEEL FIO FURNISHED AND INSTALLED BY OWNER STRUC STRUCTURAL FLA FULL LOAD AMPS TA TRANSFER AIR FLEX FLEXIBLE TEMP TEMPERATURE/TEMPORARY FLR FLOOR TBD TO BE DETERMINED FOB FLAT ON BOTTOM TOD TOP OF DUCT FOIC FURNISHED BY OTHERS, TOS TOP OF STEEL/TOP OF SLAB INSTALLED BY CONTRACTOR TOT TOTAL FOS FLAT ON SIDE TSP TOTAL STATIC PRESSURE FOT FLAT ON TOP TSTAT THERMOSTAT FP FIRE PROTECTION TYP TYPICAL FPM FEET PER MINUTE UH UNIT HEATER FSD FIRE/SMOKE DAMPER UNO UNLESS NOTED OTHERWISE FT FOOT/FEET V VOLT FUT FUTURE VD VOLUME DAMPER FV FACE VELOCITY VEL VELOCITY G GRILLE VERT VERTICAL GA GAUGE/GALLON VFD VARIABLE FREQUENCY DRIVE GALV GALVANIZED VOL VOLUME GC GENERAL CONTRACTOR W WRAPPED DUCT GPM GALLONS PER MINUTE WB WET BULB GRD GRILLE/REGISTER/DIFFUSER WG WATER GAUGE GWB GYPSUM WALL BOARD W/ WITH HD HEAD W/0 WITHOUT HORIZ HORIZONTAL W/SF WATTS PER SQUARE FOOT HP HORSEPOWER WSEC WASHINGTON STATE ENERGY CODE HR HOUR HSPF HEATING SEASONAL PERFORMANCE FACTOR HT HEIGHT HWTG HIGH WALL TRANSFER GRILLE HWR HOT WATER RETURN HWS HOT WATER SUPPLY HX HEAT EXCHANGER HZ HERTZ MECHANICAL LEGEND 10X10 10X`1®1 10X10 10X10 �1�1 10X10 10X`�l 10X10 1oX�- 10 100 100 100 12X100 12X100; E10 � 100 100 100 100 -3:2 100 t 10:�: DD -A RECT SUPPLY AIR DUCT UP/TOWARD RECT SUPPLY AIR DUCT DN/AWAY RECT EXHAUST OR RETURN DUCT UP/TOWARD RECT EXHAUST OR RETURN DUCT DN/AWAY ROUND DUCT - UP/TOWARD ROUND DUCT - DN/ AWAY MECHANICAL GENERAL NOTES 1. WORK SHALL CONFORM TO APPLICABLE CODES AND REGULATIONS, INCLUDING, BUT NOT LIMITED TO THE 2015 IBC, 2015 WSEC, & 2015 IMC. WITH WASHINGTON STATE AMENDMENTS 2. DO NOT SCALE DRAWINGS, DIMENSIONS GOVERN. DIMENSIONS ARE TO FACE OF STUD, CONCRETE, OR MASONRY UNO. 3. LOCATION AND DETAILS OF EQUIPMENT, DUCT ROUTING, AND CONNECTIONS ARE APPROXIMATE. COORDINATE FINAL LOCATIONS WITH OTHER TRADES. INSTALL IN ACCORDANCE WITH APPROVED SUBMITTALS AND DETAIL DRAWINGS WHEN APPLICABLE. 4. VERIFY EXISTING CONDITIONS, DIMENSIONS, DETAILS, ETC. NOTIFY ENGINEER OF ANY DISCREPANCIES PRIOR TO PROCEEDING WITH WORK. 5. WHEN CONSTRUCTION DETAILS ARE NOT SHOWN OR NOTED FOR ANY PART OF THE WORK, DETAILS SHALL BE THE SAME AS FOR OTHER SIMILAR WORK. IF ADDITIONAL QUESTIONS REMAIN, CONTACT THE ENGINEER PRIOR TO PROCEEDING. 6. ALL STRUCTURAL OPENINGS AND PLATFORMS SHALL BE PROVIDED BY THE GENERAL CONTRACTOR UNO. 7. DUCT SEALING AND CONSTRUCTION TO MEET SMACNA AND ENERGY CODE REQUIREMENTS. UNLESS OTHERWISE NOTED, LOW PRESSURE DUCTWORK SEAL CLASS C.OF VAV MEDIIUMBPRESSURE CONSTANT DUCTW RK (UPSTREAM OF SYSTEMS, ILET BOXES,HH GHSVELOCIlYTEXHAUSTS, MEET 2" CONSTRUCTION STANDARDS 4" CONSTRUCTION ITH STANDARDS WITH SEAL CLASS A. DUCT RISERS IN SHAFTS WITH DAMPERED PENETRATIONS TO MEET 6" CONSTRUCTION STANDARDS WITH SEAL CLASS A. 8. ALL CEILING DIFFUSERS ARE 4 -WAY THROW UNLESS NOTED OTHERWISE. 9. ALL DUCT DIMENSIONS ARE OUTSIDE DIMENSIONS BEFORE SOUND LINING HAS BEEN ACCOUNTED FOR (SOUND LINING @ 1", UNO) FLATOVAL DUCT - UP/ TOWARD 10. OUTSIDE AIR INTAKES ON ALL AIR HANDLING UNITS SHALL BE 10 FEET AWAY FROM ANY VENTS, STREETS, LOADING DOCK, FLATOVAL DUCT - DN/ AWAY NEIGHBORING LOT LINES & FUEL BURNING EQUIPMENT OR 3 FEET BELOW OR 25 ABOVE ANY CONTAMINANT SOURCE WITHIN 10 FEET. 11. ALL AIR ECONOMIZERS SHALL BE CAPABLE OF THE FOLLOWING PER C403.3.1 & C403.2.4.7: -0% TO 100% OF THE DESIGN SUPPLY AIR WITH FAULT DETECTION & DIAGNOSTIC REPORTING. DUCT OVERLAP -CONTROLLED BY A CONTROL SYSTEM DETERMINING IF THE OUTSIDE AIR CAN MEET PART OR ALL OF THE BUILDING COOLING LOADS. -INTEGRATED TO PROVIDE PARTIAL COOLING EVEN WHEN MECHANICAL COOLING IS REQUIRED. BOOT TAP 45' TAP VOLUME DAMPER CALIBRATED BALANCING DAMPER RISER) & DROP(D) TRANSITION TURNING VANES/SPLITTERS DUCT MOUNTED SMOKE DETECTOR BACK DRAFT DAMPER FLEXIBLE DUCT AIR FLOW (FORCED AIR) COMBINATION FSD FIRE DAMPER SMOKE DAMPER MOTOR OPERATED DAMPER y w 0 ACCESS DOORS SOUND TRAP FLEX CONNECTION 16X160DSL ACOUSTICALLY LINED DUCT OD = OUTSIDE DIMENSIONS SL = SOUND LINING (THICKNESS) 1 Q99 � FABRIC DUCT ® CLEARANCE ® SUPPLY AIR DIFFUSER (WITH CORE BLANKOFF) CEILING RETURN, TRANSFER OR EXHAUST AIR GRILLE o SLOTTED DIFFUSER (PLAN VIEW) C3A REVISION CLOUD & TRIANGLE ##0 ROUND DUCT SYMBOL ##X## 0 FLATOVAL DUCT SYMBOL ##° DEGREES SYMBOL ® POINT OF CONNECTION CD1-100 GRD TAG IDENTIFIER = TYPE -CFM 80 SIZE 0 T'STAT/TEMP SENSOR 1 0� CARBON DIOXIDE HUMIDITY SENSOR SENSOR sD SMOKE DETECTOR Co CARBON MONOXIDE sP STATIC PRESSURE SENSOR SENSOR 12. OUTSIDE AIR INTAKE, RELIEF, AND EXHAUST OPENINGS SHALL BE CLASS 1 AND EQUIPPED WITH MOTORIZED (OR GRAVITY PER EXCEPTIONS IN C403.2.4.3) DAMPERS WHICH CLOSE AUTOMATICALLY WHEN SYSTEM IS OFF OR UPON POWER FAILURE, UNO FOR SMOKE CONTROL SYSTEM OPERATION 13. THE CONTROL SYSTEM SHALL MEET C403 AND BE PROGRAMMABLE, CAPABLE OF BEING SET FOR DIFFERENT DAY TYPES PER WEEK, DEADBAND SETTING OF AT LEAST 5F (10T FOR RESIDENTIAL BETWEEN THE HEATING AND COOLING SETPOINTS AND SETBACK TEMPERATURES WITH OPTIMAL START CONTROL. CONTROL SYSTEM SHALL INCLUDE A MICROPROCESSOR AND BE CAPABLE OF VARYING FLOWS AND RESETTING SUPPLY AIR & WATER TEMPERATURES BY REPRESENTATIVE BUILDING LOADS WHERE REQUIRED IN C403.4. 14. WHERE REQUIRED BY C408, RECORD DRAWINGS OF THE ACTUAL INSTALLATION SHALL BE PROVIDED TO THE BUILDING OWNER WITHIN 90 DAYS OF THE DATE OF SYSTEM ACCEPTANCE PER THE ENERGY CODE. AN OPERATING MANUAL AND MAINTENANCE MANUAL SHALL BE PROVIDED TO THE BUILDING OWNER. ALL HVAC SYSTEMS SHALL BE BALANCED AND A WRITTEN BALANCING REPORT SHALL BE PROVIDED TO THE OWNER. HVAC CONTROL SYSTEMS SHALL BE TESTED TO ENSURE THAT THEY OPERATE IN ACCORDANCE WITH APPROVED PLANS. A PRELIMINARY COMMISSIONING REPORT OF TEST PROCEDURES AND RESULTS SHALL BE PREPARED PRIOR TO ISSUANCE OF A FINAL CERTIFICATE OF OCCUPANCY. A COMPLETE FINAL COMMISSIONING REPORT OF TEST PROCEDURES AND RESULTS SHALL BE PROVIDED TO THE OWNER. 15. MECHANICAL SYSTEMS SHALL COMPLY WITH SEISMIC RESTRAINT REQUIREMENTS OF THE BUILDING CODE, SMACNA AND ASCE 7. ALL LIFE SAFETY OR HAZARDOUS MATERIAL RELATED SYSTEMS SHALL BE DEEMED AN Ip=1.5 FOR RESTRAINT METHODS OR AS NOTED ON THE DRAWINGS. REFER TO CODES FOR INSTALLATION REQUIREMENTS AND EXCEPTIONS BASED ON SIZING, WEIGHTS AND MOUNTING HEIGHTS. 16. PROVIDE EARTHQUAKE RESTRAINTS FOR HVAC EQUIPMENT AS REQUIRED BY SMACNA SEISMIC RESTRAINT MANUAL, SEISMIC HAZARD B. WIRES FOR CEILING SYSTEM ETC. SHALL NOT BE HUNG OFF HVAC EQUIPMENT OR HVAC EQUIPMENT SUPPORTS. 17. PROVIDE FIRE AND COMBINATION FIRE/SMOKE DAMPERS WHERE SHOWN ON PLANS AND WHERE REQUIRED PER CODE. 18. ALL PIPING PENETRATIONS THROUGH RATED ASSEMBLIES SHALL BE SEALED WITH AN UL APPROVED FIRE CAULKING. 19. SMOKE DETECTORS PROVIDING AUTOMATIC SHUTDOWN SHALL BE PROVIDED FOR HVAC EQUIPMENT DELIVERING >2000 CFM (INCLUDING MULTIPLE UNITS DUCTED INTO COMMON DISTRIBUTION OR RETURN, WITH A TOTAL SUPPLY >2000 CFM) OR EACH STORY OF RETURN SYSTEMS OVER 15,000 CFM IN A MULTI -STORY INSTALLATION, PER CODE. SMOKE DETECTORS SHALL BE FIC (ELEC) UNO. POWER -WIRING AND INTERLOCK TO FIRE ALARM SYSTEM BY ELECTRICAL CONTRACTOR AS APPLICABLE. VAV BOX (WITH FAN) SHUTDOWN CAN BE THROUGH CONTROLS SYSTEM. 20. MECHANICAL ACCESS PANELS SI-IALL BE PROVIDED BY MECHANICAL CONTRACTOR AND INSTALLED BY GENERAL CONTRACTOR. 21. ALL MOTOR STARTERS NOT SHOWN IN EQUIPMENT SCHEDULES SHALL BE FURNISHED AND INSTALLED BY ELECTRICAL CONTRACTOR. MOTOR EFFICIENCIES TO MEET OR EXCEED CODE MINIMUM. 22. FOR ALL "SEALED AIR TIGHT" OR PRESSURIZED SHAFTS/ROOMS, THE FOLLOWING SHALL OCCUR: -ALL VERTICAL JOINTS & CORNERS SHALL BE PROVIDED WITH A CONTINUOUS SEAL FOR THE LENGTH OF THE JOINT (BY GC). -TOP AND BOTTOM WALL TRACKS SHOULD BE CAULKED ALONG THEIR ENTIRE LENGTH (BY GC). -ANY FLOOR DECKING PERPENDICULAR TO THE CONSTRUCTION SHALL BE CAULKED (BY GC). FILLING WITH ROCK WOOL IS NOT ACCEPTABLE. -ANY PENETRATIONS OF THE CONSTRUCTION (DUCTWORK CONDUIT PIPING ...) SHALL BE SEALED ON BOTH SIDES -ALL DOORS SHALL BE PROVIDED WITH TIGHT FITTING GASKETS MD THRESHOLD SWEEPS, AND OPEN AGAINST THE DIRECTION OF PRESSURE. -USE SECTION 909.5 OF THE 2012 IBC FOR MAX ALLOWABLE LEAKAGE AREA, FOLLOWING THE GUIDELINES FOR TIGHT STAIR SHAFT CONSTRUCTION. 23. ALL ADHESIVES, SEALANTS, PAINTS AND COATINGS USED DURING THE INSTALLATION/FINISH WORK SHALL MEET THE LEED REQUIREMENTS FOR IEQ. 24. MAXIMUM STANDARD LENGTH OF FLEXIBLE DUCT SHALL BE 12 FEET; UP TO 25' MAXIMUM LENGTH IS ACCEPTABLE IF; REFER TOT INSTALLATION TESTED FOR 'SUPPORTOREWREMENTS D FLEX BLE DUCTS FLAMEBSPREADMRATING I SHALLBBE D< 250 ANDD SMOKED DEVELOPEDRATING SHALL BE < 50. USE THERMAFLEX MODEL G -KM FOR LOW AND MEDIUM PRESSURE APPLICATIONS OR APPROVED EQUAL. 25. ELECTRICAL METERING OF SYSTEMS AS REQUIRED BY ENERGY CODE SECTION C409 IS BY ELECTRICAL. THE ELECTRICAL DESIGN & CONTRACTOR TEAM WILL FURNISH THE NECESSARY ELECTRICAL DISTRIBUTION AND METERING COMPONENTS - SEE ELECTRICAL DRAWINGS. THE MECHANICAL CONTRACTOR WILL FURNISH A BUILDING MANAGEMENT SYSTEM CAPABLE OF COLLECTING AND STORING THE INFORMATION WITH A VISIBLE DISPLAY/NOTIFICATION READILY ACCESSIBLE TO OPERATION AND MANAGEMENT PERSONNEL AS REQUIRED. EXISTING DUCTWORK UPDATED DEMO DUCTWORK I WALL -MOUNTED GRILLE oo PIPE ELBOW UP SUPPLY & RETURN PIPE ELBOW DN R-8 DIRECTION OF FLOW -" DIRECTION OF SLOPE DOWN 7 PLUG OR CAP SUPPLY & RETURN PRESS REDUCING ASSEMBLY ---��--� SOLENOID VALVE SUPPLY AIR <550 OR >1050 PUMP Z--CHWS /CHWR-s CHILLED WATER SUPPLY/RETURN t-- RL/RS -s REFRIGERANT LIQUID/SUCTION r- NG -i NATURAL GAS 2- LPG -s LIQUID PROPANE GAS Z-CDWS /CDWR-s CONDENSER WATER SUPPLY/RET 2-HWS/HWR-s HEATING WATER SUPPLY/RETURN 2- COND -S CONDENSATE r- FOV --s FUEL OIL VENT 2- FOS / FOR --s FUEL OIL SUPPLY/RETURN z RDG REFRIGERANT DISCHARGE GAS 12. OUTSIDE AIR INTAKE, RELIEF, AND EXHAUST OPENINGS SHALL BE CLASS 1 AND EQUIPPED WITH MOTORIZED (OR GRAVITY PER EXCEPTIONS IN C403.2.4.3) DAMPERS WHICH CLOSE AUTOMATICALLY WHEN SYSTEM IS OFF OR UPON POWER FAILURE, UNO FOR SMOKE CONTROL SYSTEM OPERATION 13. THE CONTROL SYSTEM SHALL MEET C403 AND BE PROGRAMMABLE, CAPABLE OF BEING SET FOR DIFFERENT DAY TYPES PER WEEK, DEADBAND SETTING OF AT LEAST 5F (10T FOR RESIDENTIAL BETWEEN THE HEATING AND COOLING SETPOINTS AND SETBACK TEMPERATURES WITH OPTIMAL START CONTROL. CONTROL SYSTEM SHALL INCLUDE A MICROPROCESSOR AND BE CAPABLE OF VARYING FLOWS AND RESETTING SUPPLY AIR & WATER TEMPERATURES BY REPRESENTATIVE BUILDING LOADS WHERE REQUIRED IN C403.4. 14. WHERE REQUIRED BY C408, RECORD DRAWINGS OF THE ACTUAL INSTALLATION SHALL BE PROVIDED TO THE BUILDING OWNER WITHIN 90 DAYS OF THE DATE OF SYSTEM ACCEPTANCE PER THE ENERGY CODE. AN OPERATING MANUAL AND MAINTENANCE MANUAL SHALL BE PROVIDED TO THE BUILDING OWNER. ALL HVAC SYSTEMS SHALL BE BALANCED AND A WRITTEN BALANCING REPORT SHALL BE PROVIDED TO THE OWNER. HVAC CONTROL SYSTEMS SHALL BE TESTED TO ENSURE THAT THEY OPERATE IN ACCORDANCE WITH APPROVED PLANS. A PRELIMINARY COMMISSIONING REPORT OF TEST PROCEDURES AND RESULTS SHALL BE PREPARED PRIOR TO ISSUANCE OF A FINAL CERTIFICATE OF OCCUPANCY. A COMPLETE FINAL COMMISSIONING REPORT OF TEST PROCEDURES AND RESULTS SHALL BE PROVIDED TO THE OWNER. 15. MECHANICAL SYSTEMS SHALL COMPLY WITH SEISMIC RESTRAINT REQUIREMENTS OF THE BUILDING CODE, SMACNA AND ASCE 7. ALL LIFE SAFETY OR HAZARDOUS MATERIAL RELATED SYSTEMS SHALL BE DEEMED AN Ip=1.5 FOR RESTRAINT METHODS OR AS NOTED ON THE DRAWINGS. REFER TO CODES FOR INSTALLATION REQUIREMENTS AND EXCEPTIONS BASED ON SIZING, WEIGHTS AND MOUNTING HEIGHTS. 16. PROVIDE EARTHQUAKE RESTRAINTS FOR HVAC EQUIPMENT AS REQUIRED BY SMACNA SEISMIC RESTRAINT MANUAL, SEISMIC HAZARD B. WIRES FOR CEILING SYSTEM ETC. SHALL NOT BE HUNG OFF HVAC EQUIPMENT OR HVAC EQUIPMENT SUPPORTS. 17. PROVIDE FIRE AND COMBINATION FIRE/SMOKE DAMPERS WHERE SHOWN ON PLANS AND WHERE REQUIRED PER CODE. 18. ALL PIPING PENETRATIONS THROUGH RATED ASSEMBLIES SHALL BE SEALED WITH AN UL APPROVED FIRE CAULKING. 19. SMOKE DETECTORS PROVIDING AUTOMATIC SHUTDOWN SHALL BE PROVIDED FOR HVAC EQUIPMENT DELIVERING >2000 CFM (INCLUDING MULTIPLE UNITS DUCTED INTO COMMON DISTRIBUTION OR RETURN, WITH A TOTAL SUPPLY >2000 CFM) OR EACH STORY OF RETURN SYSTEMS OVER 15,000 CFM IN A MULTI -STORY INSTALLATION, PER CODE. SMOKE DETECTORS SHALL BE FIC (ELEC) UNO. POWER -WIRING AND INTERLOCK TO FIRE ALARM SYSTEM BY ELECTRICAL CONTRACTOR AS APPLICABLE. VAV BOX (WITH FAN) SHUTDOWN CAN BE THROUGH CONTROLS SYSTEM. 20. MECHANICAL ACCESS PANELS SI-IALL BE PROVIDED BY MECHANICAL CONTRACTOR AND INSTALLED BY GENERAL CONTRACTOR. 21. ALL MOTOR STARTERS NOT SHOWN IN EQUIPMENT SCHEDULES SHALL BE FURNISHED AND INSTALLED BY ELECTRICAL CONTRACTOR. MOTOR EFFICIENCIES TO MEET OR EXCEED CODE MINIMUM. 22. FOR ALL "SEALED AIR TIGHT" OR PRESSURIZED SHAFTS/ROOMS, THE FOLLOWING SHALL OCCUR: -ALL VERTICAL JOINTS & CORNERS SHALL BE PROVIDED WITH A CONTINUOUS SEAL FOR THE LENGTH OF THE JOINT (BY GC). -TOP AND BOTTOM WALL TRACKS SHOULD BE CAULKED ALONG THEIR ENTIRE LENGTH (BY GC). -ANY FLOOR DECKING PERPENDICULAR TO THE CONSTRUCTION SHALL BE CAULKED (BY GC). FILLING WITH ROCK WOOL IS NOT ACCEPTABLE. -ANY PENETRATIONS OF THE CONSTRUCTION (DUCTWORK CONDUIT PIPING ...) SHALL BE SEALED ON BOTH SIDES -ALL DOORS SHALL BE PROVIDED WITH TIGHT FITTING GASKETS MD THRESHOLD SWEEPS, AND OPEN AGAINST THE DIRECTION OF PRESSURE. -USE SECTION 909.5 OF THE 2012 IBC FOR MAX ALLOWABLE LEAKAGE AREA, FOLLOWING THE GUIDELINES FOR TIGHT STAIR SHAFT CONSTRUCTION. 23. ALL ADHESIVES, SEALANTS, PAINTS AND COATINGS USED DURING THE INSTALLATION/FINISH WORK SHALL MEET THE LEED REQUIREMENTS FOR IEQ. 24. MAXIMUM STANDARD LENGTH OF FLEXIBLE DUCT SHALL BE 12 FEET; UP TO 25' MAXIMUM LENGTH IS ACCEPTABLE IF; REFER TOT INSTALLATION TESTED FOR 'SUPPORTOREWREMENTS D FLEX BLE DUCTS FLAMEBSPREADMRATING I SHALLBBE D< 250 ANDD SMOKED DEVELOPEDRATING SHALL BE < 50. USE THERMAFLEX MODEL G -KM FOR LOW AND MEDIUM PRESSURE APPLICATIONS OR APPROVED EQUAL. 25. ELECTRICAL METERING OF SYSTEMS AS REQUIRED BY ENERGY CODE SECTION C409 IS BY ELECTRICAL. THE ELECTRICAL DESIGN & CONTRACTOR TEAM WILL FURNISH THE NECESSARY ELECTRICAL DISTRIBUTION AND METERING COMPONENTS - SEE ELECTRICAL DRAWINGS. THE MECHANICAL CONTRACTOR WILL FURNISH A BUILDING MANAGEMENT SYSTEM CAPABLE OF COLLECTING AND STORING THE INFORMATION WITH A VISIBLE DISPLAY/NOTIFICATION READILY ACCESSIBLE TO OPERATION AND MANAGEMENT PERSONNEL AS REQUIRED. 1 Ktf tK I U UgW.L.6 1 -UK t -UK I HtK KtC2UIKtMtN 15 & ALSU K4UJ 1 -UK KtblUtN I IAL 1Nb I ALLA I TUNS 2 INSULATED COOLED DUCTS REQUIRED A VAPOR RETARDER (PERM < 0.5) AND SEALED JOINTS 3 WEATHERPROOF BARRIER REQUIRED AROUND DUCTWORK TO MAINTAIN WATER TIGHTNESS 4 INSULATE OUTSIDE AIR DUCTS TO BUILDING EXTERIOR WALL LEVEL PER ENERGY CODE SECTION: C403.2.8.1 UNTIL CONNECTED TO EQUIPMENT SERVED OR TO THE CODE REQUIRED SHUTOFF DAMPER (AND '"THICK INSULATION MIN. TO PREVENT CONDENSATION ON DUCTS IN PLENUM UP TO THE HEATING OR COOLING EQUIPMENT) 5 R-7 CAN BE USED IN LIEU OF BUILDING ENVELOPE INSULATION LEVEL IF: DEDICATED OUTSIDE AIR SYSTEM AND <2,800 CFM SUPPLY AIR MINIMUMIPE INSULATION LAST UPDATED: 07/11/16 MINIMUMPUCT INSULATIONLAST UPDATED 07/11/16 DUCT TYPE DUCT LOCATION (IN HEATED AND MECHANICALLY COOLED DUCT SYSTEM) INSULATION R -VALUE REMARKS SUPPLY & RETURN NOT WITHIN CONDITIONED SPACE: OUTSIDE BUILDING R-8 1,2,3 OUTSIDE AIR WITHIN CONDITIONED SPACE: INSIDE BUILDING SEE NOTES 4 & 5 1,2,3,4,5 SUPPLY & RETURN NOT WITHIN CONDITIONED SPACE: INSIDE BUILDING R-6 1,2 SUPPLY AIR <550 OR >1050 WITHIN CONDITIONED SPACE R-3.3 112 1 Ktf tK I U UgW.L.6 1 -UK t -UK I HtK KtC2UIKtMtN 15 & ALSU K4UJ 1 -UK KtblUtN I IAL 1Nb I ALLA I TUNS 2 INSULATED COOLED DUCTS REQUIRED A VAPOR RETARDER (PERM < 0.5) AND SEALED JOINTS 3 WEATHERPROOF BARRIER REQUIRED AROUND DUCTWORK TO MAINTAIN WATER TIGHTNESS 4 INSULATE OUTSIDE AIR DUCTS TO BUILDING EXTERIOR WALL LEVEL PER ENERGY CODE SECTION: C403.2.8.1 UNTIL CONNECTED TO EQUIPMENT SERVED OR TO THE CODE REQUIRED SHUTOFF DAMPER (AND '"THICK INSULATION MIN. TO PREVENT CONDENSATION ON DUCTS IN PLENUM UP TO THE HEATING OR COOLING EQUIPMENT) 5 R-7 CAN BE USED IN LIEU OF BUILDING ENVELOPE INSULATION LEVEL IF: DEDICATED OUTSIDE AIR SYSTEM AND <2,800 CFM SUPPLY AIR MINIMUMIPE INSULATION LAST UPDATED: 07/11/16 FLUID DESIGN INSULATION CONDUCTIVITY NOMINAL PIPE DIAMETER (INCH) OPERATING TEMP °F CONDUCTIVITY RANGE MEAN TEMP RATING OF <1 1 TO <1-1/2 1-1/2TO <4 4 TO <8 18 HEATING SYSTEMS (STEAM, CONDENSATE, HYDRONIC HOT WATER, DOMESTIC HOT WATER & RECIRC) >350 0.32-0.34 250 4.5 5.0 5.0 5.0 5.0 251-350 0.29-0.32 200 3.0 4.0 4.5 4.5 4.5 201-250 0.27-0.30 150 2.5 2.5 2.5 3.0 3.0 141-200 0.25-0.29 125 1.5 1.5 2.0 2.0 2.0 105-140 0.21-0.28 100 1.0 1.0 1.5 1.5 1.5 DOMESTIC COLD WATER AND HORIZONTAL RAIN LEADERS TO FIRST VERTICAL RAIN LEADER (TO PREVENT CONDENSATION) N/A 1 0.21-0.27 1 75 1 0.5 1 0.5 T 0.5 F 0.5 0.5 COOLING SYSTEMS (CHILLED WATER, BRINE AND REFRIGERANT, WATERSIDE ECONOMIZER SYSTEMS)** 40-60 0.21-0.27 75 0.5 0.5 1.0 1.0 1.0 <40 0.20-0.26 75 0.5 1 1.0 1.0 1.0 1.5 NOTE: * NOT REQUIRED FOR STRAINERS, CONTROL VALVES & BALANCING VALVES ASSOCIATED WITH PIPING 1" OR LESS IN DIA. ** TYPICAL CONDENSER WATER PIPE IN NON -ECONOMIZER SYSTEMS IS NOT INSULATED SEE R403 FOR RESIDENTIAL INSTALLATIONS. DRAWING INDEX SHEET NO. SHEET TITLE CURRENT REVISION M0.00 LEGEND, ABBREVIATIONS, GENERAL NOTES, & SHEET INDEX - HVAC M2.01 PARTIAL 1ST FLOOR PLANS, ELEVATION, DETAIL & SCHEDULE - HVAC 1 3623049057 LEGAL DESCRIPTION LOT 2 OF RENTON SHORT PLAT NO 346-79 REC NO 7907169001 SD PLAT DAF -POR GL 2 & NE 1/4 OF NW 1/4 SD SEC LY ELY OF WEST VALLEY ROAD & WLY OF PSE R/W & LY NLY OF LN WCH IS 756 FT N OF MEAS AT R/A THOF & PLT N LN OF S 180 TH ST LESS POR CONV FOR SR 181 Building Today, Defining Tomorrow Hermanson Company LLP 1221 2nd Avenue North Kent, Washington 98032 Tel: (206) 575-9700 Fax: (206) 575-9800 www.hermanson.com Contractor Reg #: HERMACLO05BJ UNITED RENTAL SHOP EXHAUST FAN 17700 W. VALLEY HWY TUKWILA, WA 98188 VICINITY MAP NO SCALE SITE IAP NO SCALE EVISIONS filo Ct121nq2S Sit^!I hr, r;,,:�,Cl­� to tho ;cc>pF of work withoi.i: prior apl)ro\t,.1 of Tu!cwi!a Building Givicion !OTE: Revisicns will rccluiro a n, -,..v plan submittal and may inc,ude additional p'an rcviev° fees I RLECOPY Permit No. i' UhieCt to errori and , r Ai.lproval X91 8 f�. 't yd9 F CEtri . i i, i " L. �1 I� i the violation or � qjv s:tdopj@o, co do o. `frdlt?a�?�s of approves? �::ioid i:opy and coed-lijo3ec, i3 Date: CitY Of TuWjila BUILDING DIVISION 6010114 ; N :3 y a Oki Revisions 2L 12/09/16 JMH PERMIT CORRECTION 11/11/16 JMH ISSUE FOR PERMIT No. Date By Description Design Team Design JMH Drawn FVP Checked DTN Scale AS NOTED Drawing Number C-0674-06041 Project Number 14-16-06041 Issue Date 11/11/16 LEGEND, ABBREVIATION, GENERAL NOTES & SHEET INDEX -HVAC ❑c'?iL ;.n�;cal Ytv'r] �. Electrical i� iuinbing o R� i E C Gas Piping Ci,,j of Tukwila TR ! _k��I CrIV'ISIOv .. 'IEWED F® RECEIV UO(OCOMP LI°AP ITY' OF TU ® PROVED JAN 3 0 2047 FEB 02 X01 ERfUlfT CENTER NJ of TukWilc' C°M o� (� A ? 9 ti ^ a SITE IAP NO SCALE EVISIONS filo Ct121nq2S Sit^!I hr, r;,,:�,Cl­� to tho ;cc>pF of work withoi.i: prior apl)ro\t,.1 of Tu!cwi!a Building Givicion !OTE: Revisicns will rccluiro a n, -,..v plan submittal and may inc,ude additional p'an rcviev° fees I RLECOPY Permit No. i' UhieCt to errori and , r Ai.lproval X91 8 f�. 't yd9 F CEtri . i i, i " L. �1 I� i the violation or � qjv s:tdopj@o, co do o. `frdlt?a�?�s of approves? �::ioid i:opy and coed-lijo3ec, i3 Date: CitY Of TuWjila BUILDING DIVISION 6010114 ; N :3 y a Oki Revisions 2L 12/09/16 JMH PERMIT CORRECTION 11/11/16 JMH ISSUE FOR PERMIT No. Date By Description Design Team Design JMH Drawn FVP Checked DTN Scale AS NOTED Drawing Number C-0674-06041 Project Number 14-16-06041 Issue Date 11/11/16 LEGEND, ABBREVIATION, GENERAL NOTES & SHEET INDEX -HVAC ❑c'?iL ;.n�;cal Ytv'r] �. Electrical i� iuinbing o R� i E C Gas Piping Ci,,j of Tukwila TR ! _k��I CrIV'ISIOv .. 'IEWED F® RECEIV UO(OCOMP LI°AP ITY' OF TU ® PROVED JAN 3 0 2047 FEB 02 X01 ERfUlfT CENTER NJ of TukWilc' A" BUILDING ELEVATION SCALE; 1/4" = 1'-0" FAN SCHEDULE LAST U PDAT ED: 11/08/16 UNIT TAG LOCATION AREA SERVED BASIS OF DESIGN TYPE MOUNTING LOCATION CFM ESP IN WG MOTOR CONTROLS SYSTEM DAMPER I ELECT VPH I SOUND SONES I WEIGHT LBS REMARKS BHP HP/W EF -101 WALL SHOP GREENHECK CWB-240-15 UTIL SET WALL 6 000 0.25 1.00 1.5 ON OFF TIMERI MD 1 20811 1 15 1 375 1-7 GENERAL ALL TRADES TO CONFIRM EQUIPMENT REQUIREMENTS (ELECTRICAL, WEIGHT, SIZE, ETC...) WITH APPROVED SUBMITTALS PRIOR TO INSTALLATION; FIELD COORDINATE FINAL LOCATION & INSTALL PER MANUFACTURERS REQUIREMENTS REMARKS: 1 ELECTRICAL CONTRACTOR TO PROVIDE SCCR PROTECTION FOR EQUIPMENT AS REQUIRED BY NATIONAL ELECTRICAL CODE. MANUFACTURER TO PROVIDE SCCR LISTING (5 KAIC MINIMUM) INSIDE CONTROL PANEL AS REQUIRED BY NATIONAL ELECTRICAL CODE. 2 ELECTRICAL DISCONNECT AND MOTOR STARTER (AS REQUIRED) BY ELECTRICAL CONTRACTOR 3 CONTROLLED VIA TIMER (PROVIDED AND INSTALLED WITH FAN) 4 PROVIDE WITH GALVANIZED BIRDSCREEN 5 MOTORIZED DAMPER (LINE VOLTAGE, INTERLOCKED WITH FAN OPERATION) 6 PROVIDE WITH SMARTSTART MSAC MOTOR STARTER IN A NEMA -1 ENCLOSURE 7 INTERLOCK OPERATION WITH ROLL UP DOOR SUCH THAT THE FAN WILL NOT OPERATE WHEN DOOR IS CLOSED. LE EXTERIOR WALL ve . WELDED STEEL ANGLE FRAME 3/8" NEOPRENE SECURED TO FAN HOUSING AND VIBRATION ISOLATION PAD ° d CONCRETE WALL WITH LAG (TYP ALL FOUR SIDES) ° BOLTS/EXPANSION ANCHORS d ° i MOTORIZED DAMPER EF'101 CONNECT TO PROPERLY --� SUPPORTED AND BRACED EXHAUST DUCT DAMPER MOTOR (ACCESS REQ'D) nw 20X20 THRU WALL °d F UPBLAST EXHAUST FAN, SEE SCHEDULE � BIRDGAURD WITHIN 41 FAN CONE NEMA 3R WEATHERPROOF DISCONNECT (E.C.) NOTE: AIR FLOW DIRECTION AND FAN CONFIGURATION SHALL BE AS SHOWN ON PLANS. 1 1:) WALL MOUNTED EXHAUST FAN DETAIL M� NOT TO SCALE 18" MINIMUM MAKEUP AIR OPENING PLACE INTERLOCK SENSOR AT 18" 1.1 ROLL—UP GARAGE DOOR 9 EXTERIOR ELEVATION SCALE: 1/4" = 1'-0" MAKE UP AIR CALCULATION 12/9/2016 Volume of air=6000 cfm 6000 cfm Max desired velocity=500 fpm 500 fpm = 12 square feet Minimum open'ng required= 12 square feet a 15' 25' n GRADE ISSUE FOR PERMIT ,i a 15' 25' n GRADE ISSUE FOR PERMIT