Loading...
HomeMy WebLinkAboutPermit M16-0175 - PNW IRON WORKERS - GRILLE AND DUCTWORKPNW IRONWORKERS 4550 S 134 PL EXPIRED 06/04/17 M16=0175 City of Tukwila • Department of Community Development • 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Inspection Request Line: 206-438-9350 Web site: http://www.TukwilaWA.gov MECHANICAL PERMIT Parcel No: 2613200005 Permit Number: M16-0175 Address: 4550 S 134TH PL COMPLEX Issue Date: 12/6/2016 Permit Expires On: 6/4/2017 Project Name: PNW IRONWORKERS Owner: 2015 National Electrical Code: Name: PACIFIC NW IRONWORKERS&EMPL 2015 Address: 701 FIFTH AVE STE 2200 ATT:MILT International Mechanical Code Edition: 2015 SMITH, SEATTLE, WA, 98104 2014 Contact Person: 2015 WA State Energy Code: Name: CONNIE HARDIN Phone: (206) 250-4530 Address: 4600 S 134 PL, SEATTLE, WA, 98168 Contractor: Name: HOLADAY PARKS INC Phone: (206) 248-9700 Address: 4600 S 134 PL, SEATTLE, WA, 98168 License No: HOLADPI379NO Expiration Date: 9/3/2017 Lender: Name: Address: DESCRIPTION OF WORK: INSTALL (1) GRILLE AND DUCTWORK TO EXISTING FAN Valuation of Work: $500.00 Type of Work: NEW Fuel type: ELECT Fees Collected: $159.60 Electrical Service Provided by: SEATTLE CITY LIGHT Water District: 125 Sewer District: TUKWILA Current Codes adopted by the City of Tukwila: International Building Code Edition: 2015 National Electrical Code: 2014 International Residential Code Edition: 2015 WA Cities Electrical Code: 2014 International Mechanical Code Edition: 2015 WAC 296-46B: 2014 Uniform Plumbing Code Edition: 2015 WA State Energy Code: 2015 International Fuel Gas Code: 2015 Permit Center Authorized Signature: I hearby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws r twlating construction or the performance of work. I am authorized to sign and obtain this developm nt a mit nd a re to the on itions attached to this permit. Signature: Date: (� c Print Name: 0r1 �- This permit shall become null and void if the work is not commenced within 180 days for the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. PERMIT CONDITIONS: 1: Work shall be installed in accordance with the approved construction documents, and any changes made during construction that are not in accordance with the approved construction documents shall be resubmitted for approval. 2: All permits, inspection record card and approved construction documents shall be kept at the site of work and shall be open to inspection by the Building Inspector until final inspection approval is granted. 3: All construction shall be done in conformance with the Washington State Building Code and the Washington State Energy Code. 4: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. 5: ***MECHANICAL PERMIT CONDITIONS*** 6: All mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center (206/431-3670). PERMIT INSPECTIONS REQUIRED Permit Inspection Line: (206) 438-9350 1800 MECHANICAL FINAL 0701 ROUGH -IN MECHANICAL CITY OF TUKFW..- . Community Development Department Permit Center • 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 httt)://www.TukwilaWA.Pov SITE LOCATION Mechanical Permit No. Project No. Date Application Accepted: �Q Date Application Expires: S — (0— 1 or o ce use only MECHANICAL PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. **please print** / King Co Assessor's Tax No.:�Wl o)LU()O) Site Address: l'V,`t (1l Suite Number: Floor: Tenant Name: 0.New Tenant: ❑ .....Yes R. o PROPERTY OWNER - -� Name: jOi N .1 n Address:W55—V CONTACT PERSON — person receiving all project communication Name: Me Addres 9- 1& S City• State• Z' Pho LA S ax: Emai, •1Wtr CS MECHANICAL CONTRACTOR I ORMATION Company Name: Address: QD S_ City. State: Zi q Phon L Fax: ��'' ll Contr Reg No. xp Date: Tukwila Business License No.: Valuation of project (contractor's bid price): $ Describe the scope of work in detail: I �' Use: Residential: New ..........Replacement ........ ❑ Commercial: New .......... Replacement ........ ❑ Fuel Type: Electric..... ❑ Gas....... ❑ Other: H:\Applications\Forms-Applications On Line\2016 ApplicationsWechanical Permit Application Revised 1-416.docx Revised: January 2016 bh Pagel of 2 M Indicate type of mechanical work being installed and the quantity below: Unit Type Qty Furnace <100k btu Residential, Nighttime Furnace >100k btu Industrial Floor furnace 55 dB(A) Suspended/wall/floor mounted heater 57 dB(A) Appliance vent Commercial Repair or addition to heat/refrig/cooling system 47 dB(A) Air handling unit <I0,000 cfin P Unit Type Qty Air handling unit >I0,000 cfm Residential, Nighttime Evaporator cooler Industrial Ventilation fan connected to single duct 55 dB(A) Ventilation system 57 dB(A) Hood and duct Commercial Incinerator — domestic 47 dB(A) Incinerator — comm/industrial P Unit Type Qty Fire damper Residential, Nighttime Diffuser Industrial Thermostat 55 dB(A) Wood/gas stove 57 dB(A) Emergency enerator Commercial Other mechanical equipment 47 dB(A) 60 dB(A) P Boiler/Compressor I Qty 0-3 hp/100,000 btu 3-15 h /500,000 btu 15-30 hp/1,000,000 btu 30-50 hp/1,750,000 btu 50+ hp/1,750,000 btu Noise: Mechanical units need to be in compliance with the Tukwila Noise Code. Maximum permissible sound levels are based on from where the sound is created and where the sound is heard. Additionally, if sound can be heard from within a house at night in a residential zone it may not be allowed. For more details, see TMC 8.22 District of Sound Producing Source District of Receiving Property Residential, Daytime* Residential, Nighttime Commercial Industrial Residential 55 dB(A) 45 Q(A) 57 dB(A) 60 Q(A) Commercial 57 dB(A) 47 dB(A) 60 dB(A) 65 dB(A) Industrial 60 dB(A) 50 dB(A) 65 dB(A) 70 dB(A) *Daytime means 7AM-IOPM, Monday through Friday and 8AM-IOPM, Saturday, Sunday and State -recognized holidays. A few sounds are exempt from the noise code, including: Warning devices; Construction and property maintenance during the daytime hours (lam -I Opm); Testing of backup generators during the day. PERMIT APPLICATION NOTES - Value of construction — in all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the permit center to comply with current fee schedules. Expiration of plan review — applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The building official may grant one extension of time for additional periods not to exceed 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. t,tty nate alp H:\Applications\Forms-Applications On Line\2016 ApplicationsWechanical Permit Application Revised 1-4-16.docx Revised: January 2016 Page 2 of 2 bb DESCRIPTIONS PermitTRAK ACCOUNT QUANTITY PAID $159.60 M16-0175 Address: 4550 5 134TH PL COMPLEX Apn: 2613200005 $159.60 MECHANICAL $153.46 PERMIT ISSUANCE BASE FEE R000.322.100.00.00 0.00 $32.50 PERMIT FEE R000.322.100.00.00 0.00 $90.27 PLAN CHECK FEE R000.322.102.00.00 0.00 $30.69 TECHNOLOGY FEE $6.14 TECHNOLOGY FEE TOTALR9881 R000.322.900.04.00 0.00 $6.14 $159.60 Date Paid: Friday, November 18, 2016 Paid By: CONNIE HARDIN Pay Method: CREDIT CARD 08116G Printed: Friday, November 18, 2016 1:21 PM 1 of 1 N?SY57EM5 )e X" EXISTING GAS UNIT HEATER A u1 EN _ l 1 REPIL CE J4. ' W i TEE iE5 i � 400 (TW TF�A€N'a~�s !7�I� - MEN o �7hm � mil�u�upumuu ` _ � J4N ---- - - ------- AY ......_ ttAL I 1X4" t %VIS'UNS +No ch i ! - .. e STmade to thy! scopes - Of lorl< with1--;prior approve of OFFICE i'�+`"rll Alii," i,!QrfnE H� L Ux Y �A v, 1s t".i r�.�;:!,� .! plate submittal anJ m y in�'ude Ilddtionai plan reviel fees l!!_!' ':SON Jae he ING GAS HEATER Plan APA the of ao _ _T LEVEL 1 HVAC PLAN SCALE: 213T a T-0' $TORAGE __21a -- RELOCATED EXISTING GAS UNIT (HEATER EXISTING �RXEENHE G-080-GEFAN ON ROOF FILE 41010PY lrmit 0. t ' _0hq-_ Iw "�Ipnroval is sub ect to errors and of of cansifuiaiion documen!s does not C m of any adapted code or ordinance. A HOLADAr PARKS, INC SMART Mechanical Solutiionsa Mechanical Solutions . Energy Services Building Controls . Service 8 Maintenance 4600 S. 134TH PLACE SEATTLE, WA 98168. (206) 248-9700 aA?a T � ? r w J �' I- )e X" EXISTING GAS UNIT HEATER A u1 EN _ l 1 REPIL CE J4. ' W i TEE iE5 i � 400 (TW TF�A€N'a~�s !7�I� - MEN o �7hm � mil�u�upumuu ` _ � J4N ---- - - ------- AY ......_ ttAL I 1X4" t %VIS'UNS +No ch i ! - .. e STmade to thy! scopes - Of lorl< with1--;prior approve of OFFICE i'�+`"rll Alii," i,!QrfnE H� L Ux Y �A v, 1s t".i r�.�;:!,� .! plate submittal anJ m y in�'ude Ilddtionai plan reviel fees l!!_!' ':SON Jae he ING GAS HEATER Plan APA the of ao _ _T LEVEL 1 HVAC PLAN SCALE: 213T a T-0' $TORAGE __21a -- RELOCATED EXISTING GAS UNIT (HEATER EXISTING �RXEENHE G-080-GEFAN ON ROOF FILE 41010PY lrmit 0. t ' _0hq-_ Iw "�Ipnroval is sub ect to errors and of of cansifuiaiion documen!s does not C m of any adapted code or ordinance. A HOLADAr PARKS, INC SMART Mechanical Solutiionsa Mechanical Solutions . Energy Services Building Controls . Service 8 Maintenance COIC E COMPLiAr - NEW RESTROOM APPROVED EC 0 2 2016 UNDERCUT DOOR 1' _ V 11/18/16 No. Dale _�y Description 1 11/18/16 RL PERMIT ISSUE CITY OF TUKWILA NOV 18 2016 PERMIT CENTER BUILDING DIVISION .. ..... .. .. =h'tlto •Ol7s LEVEL 1 HVAC PLAN M2.01 4600 S. 134TH PLACE SEATTLE, WA 98168. (206) 248-9700 HOLADAYPARKS,com WALICENSENUMBER HOLADPI379NO J �' I- U) v Z N) w W J v r( cods f -d :Lt ,op = 20 (S Y 0 � 00 � = W5 L, G a Kai Z.d (S 1 til �e �►�g a e, dw�-" Xk-)►kz0 14,00 �a �u�e�Qrv( 0 �' - �;, Q o Y RCPR WALL TIMER Z '^ vJ it FF -- TIMER TO OPERATE FAN ITINUOUSLY DURING :UPIED HOURS Deaignea by: ` EXISTING Drawn by AOProvetl by: Job Number. 43702 RESTROOM COIC E COMPLiAr - NEW RESTROOM APPROVED EC 0 2 2016 UNDERCUT DOOR 1' _ V 11/18/16 No. Dale _�y Description 1 11/18/16 RL PERMIT ISSUE CITY OF TUKWILA NOV 18 2016 PERMIT CENTER BUILDING DIVISION .. ..... .. .. =h'tlto •Ol7s LEVEL 1 HVAC PLAN M2.01 5/1/2017 City of Tukwila Department of Community Development CONNIE HARDIN 4600 S 134 PL SEATTLE, WA 98168 RE: Permit No. M16-0175 PNW IRONWORKERS 4550 S 134 PL Dear Permit Holder: Allan Ekberg, Mayor Jack Pace, Director In reviewing our current records, the above noted permit has not received a final inspection by the City of Tukwila Building Division. Per the International Building Code, International Mechanical Code, Uniform Plumbing Code and/or the National Electric Code, every permit issued by the Building Division under the provisions of these codes shall expire by limitation and become null and void if the building or work authorized by such permit has not begun within 180 days from the issuance date of such permit, or if the building or work authorized by such permit is suspended or abandoned at any time after the work has begun for a period of 180 days. Your permit will expire on 6/4/2017. Based on the above, you are hereby advised to: 1) Call the City of Tukwila Inspection Request Line at 206-438-9350 to schedule for the next or final inspection. Each inspection creates a new 180 day period, provided the inspection shows progress. -or- 2) Submit a written request for permit extension to the Permit Center at least seven(7) days before it is due to expire. Address your extension request to the Building Official and state your reason(s) for the need to extend your permit. The Building Code does allow the Building Official to approve one extension of up to 180 days. If it is determined that your extension request is granted, you will be notified by mail. In the event you do not call for an inspection and/or receive an extension prior to 6/4/2017, your permit will become null and void and any further work on the project will require a new permit and associated fees. Thank you for your cooperation in this matter. Sincerely, A —W ��Vw Bill Rambo Permit Technician File No: M16-0175 6300 Southcenter Boulevard Suite #100 • Tukwila, Washington 98188 • Phone 206-431-3670 • Fax 206-431-3665 PERMIT COOPD COPY PLAN REVIEW/ROUTING SLIP PERMIT NUMBER: M16-0175 DATE: 11/18/16 PROJECT NAME: PNW IRON WORKERS SITE ADDRESS: 4550 S 134 PL X Original Plan Submittal Response to Correction Letter # DEPARTMENTS: 0 (J X14 114 Building Division Public Works ❑ PRELIMINARY REVIEW: Not Applicable ❑ (no approval/review required) REVIEWER'S INITIALS: APPROVALS OR CORRECTIONS: Approved ❑ Corrections Required ❑ (corrections entered in Reviews) REVIEWER'S INITIALS: Revision # before Permit Issued Revision # after Permit Issued 6& J� %tw Fire Prevention 10 Structural ❑ Planning Division ❑ Permit Coordinator 4 DATE: 11/22/16 Structural Review Required ❑ DATE: DUE DATE: 12/20/16 Approved with Conditions ❑ Denied ❑ (ie: Zoning Issues) DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: 12/18/2017 HOLADAY PARKS INC Home Fspahol Contact Safety & Health Claims & Insurance Washington State Department of kI Labor & industries HOLADAY PARKS INC Owner or tradesperson 4600 S 134TH PL BECK, DAVID CARL SEATTLE, WA 98168 206-248-9700 Principals KING County BECK, DAVID CARL, PRESIDENT CONNELL, DANIEL A, PRESIDENT GIRT, BIJIT, PRESIDENT PIZZEY, GRACE K, VICE PRESIDENT FREEL, JERRY LEE, VICE PRESIDENT PARKS, GERALD T JR, PRESIDENT (End: 08/12/2015) NAILON, JUNE ANNETTE, VICE PRESIDENT (End: 08/12/2015) O'CONNOR, BONNY K, SECRETARY (End: 08/12/2015) BECK, DAVID CLARENCE, TREASURER (End: 08/12/2015) VAN DER VEEN, ERIC M, VICE PRESIDENT (End: 08/14/2013) PIZZEY, GRACE KATHERINE, VICE PRESIDENT (End: 08/14/2013) VAN DER VEEN, JULIE ELIZABETH, MEMBER (End: 08/14/2013) CONNELL, DANIEL AARON, MEMBER (End: 08/14/2013) GIRI, BUTT, MEMBER (End: 08/14/2013) KIEL, RINALD HOWARD, MEMBER (End: 08/14/2013) WHITMYRE, CHRISTIAN, MEMBER (End: 08/14/2013) NELSON, MICHAEL, SECRETARY (End: 11/04/2010) PARKS, DAVID L, TREASURER (End: 11/04/2010) TALBOT, PAUL, TREASURER (End: 11/04/2010) WA UBI No. Business type 578 004 089 Corporation Page 1 of 3 Search L&I t1-1(tka A -Z Index Help My L&I Workplace Rights Trades & Licensing Help us improve https://secure.Ini.wa.gov/verify/Detail.aspx?UBI=578004089&LIC=HOLADPI379NO&SAW= 12/6/2016 HOLADAY PARKS INC Page 2 of 3 I License Verify the contractor's active registration / license / certification (depending on trade) and any past violations. Construction Contractor Active. ...................... Meets Meets current requirements. License specialties Inspection results date GENERAL $1,000,000.00 License no. Inspection no. HOLADPI379NO 317940948 Effective — expiration Effective date 01/21/1983— 09/03/2017 11101 /2016 Bond ................. Expiration date LIBERTY MUTUAL INS CO $12,000.00 Bond account no. 23000452 Received by L&I Effective date 08/23/2002 0910112002 Expiration date Until Canceled Insurance Inspection results date Charter Oak Fire Ins Co $1,000,000.00 Policy no. Inspection no. DTCO1 F465357COF16 317940948 Received by L&I Effective date 10131/2016 11101 /2016 Expiration date 11/01/2017 Insurance history Savings No savings accounts during the previous 6 year period. Lawsuits against the bond or savings No lawsuits against the bond oI.r savings accounts during the previous 6 year period. L&I Tax debts No C& tax'debts are recorded for this contractor license during the previous 6 year period, but some debts may be recorded by other agencies. License Violations ............i............ _....viola..............t....io.... No ns"* during the previous 6 year period. Workers' comp Do you know if the business has employees? If so, verify the business is up-to-date on workers' comp premiums. L&I Account ID Account is current. 177,231-00 ................................. Doing business as HOLADAY PARKS INC Estimated workers reported Quarter 3 of Year 2016 "Greater than 100 Workers" L&I account representative T2 / LESLIE QUNELL (360)902-5631 - Email: BAKY235@lni.wa.gov Workplace safety and health Check for any past safety and health violations found on jobsites this business was responsible for. Inspection results date 09/22/2016 Under appeal. The results of the inspection are Inspection no. being challenged. 317940948 Date of appeal Location 09/29/2016 1007 Stewart St Seattle, WA 98101 Help us improve https:Hsecure.Ini.wa.gov/verify/Detail.aspx?UBI=578004089&LIC=HOLADPI379NO&SAW= 12/6/2016