HomeMy WebLinkAboutPermit M16-0175 - PNW IRON WORKERS - GRILLE AND DUCTWORKPNW IRONWORKERS
4550 S 134 PL
EXPIRED
06/04/17
M16=0175
City of Tukwila
• Department of Community Development
• 6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206-431-3670
Inspection Request Line: 206-438-9350
Web site: http://www.TukwilaWA.gov
MECHANICAL PERMIT
Parcel No: 2613200005 Permit Number: M16-0175
Address: 4550 S 134TH PL COMPLEX Issue Date: 12/6/2016
Permit Expires On: 6/4/2017
Project Name: PNW IRONWORKERS
Owner:
2015
National Electrical Code:
Name:
PACIFIC NW IRONWORKERS&EMPL
2015
Address:
701 FIFTH AVE STE 2200 ATT:MILT
International Mechanical Code Edition:
2015
SMITH, SEATTLE, WA, 98104
2014
Contact Person:
2015
WA State Energy Code:
Name:
CONNIE HARDIN
Phone: (206) 250-4530
Address:
4600 S 134 PL, SEATTLE, WA, 98168
Contractor:
Name:
HOLADAY PARKS INC
Phone: (206) 248-9700
Address:
4600 S 134 PL, SEATTLE, WA, 98168
License No:
HOLADPI379NO
Expiration Date: 9/3/2017
Lender:
Name:
Address:
DESCRIPTION OF WORK:
INSTALL (1) GRILLE AND DUCTWORK TO EXISTING FAN
Valuation of Work: $500.00
Type of Work: NEW
Fuel type: ELECT
Fees Collected: $159.60
Electrical Service Provided by: SEATTLE CITY LIGHT
Water District: 125
Sewer District: TUKWILA
Current Codes adopted by the City of Tukwila:
International Building Code Edition:
2015
National Electrical Code:
2014
International Residential Code Edition:
2015
WA Cities Electrical Code:
2014
International Mechanical Code Edition:
2015
WAC 296-46B:
2014
Uniform Plumbing Code Edition:
2015
WA State Energy Code:
2015
International Fuel Gas Code:
2015
Permit Center Authorized Signature:
I hearby certify that I have read and examined this permit and know the same to be true and correct. All
provisions of law and ordinances governing this work will be complied with, whether specified herein or not.
The granting of this permit does not presume to give authority to violate or cancel the provisions of any other
state or local laws r twlating construction or the performance of work. I am authorized to sign and obtain this
developm nt a mit nd a re to the on itions attached to this permit.
Signature: Date: (�
c
Print Name: 0r1 �-
This permit shall become null and void if the work is not commenced within 180 days for the date of issuance, or if
the work is suspended or abandoned for a period of 180 days from the last inspection.
PERMIT CONDITIONS:
1: Work shall be installed in accordance with the approved construction documents, and any changes made
during construction that are not in accordance with the approved construction documents shall be
resubmitted for approval.
2: All permits, inspection record card and approved construction documents shall be kept at the site of work
and shall be open to inspection by the Building Inspector until final inspection approval is granted.
3: All construction shall be done in conformance with the Washington State Building Code and the
Washington State Energy Code.
4: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an
approval of, any violation of any of the provisions of the building code or of any other ordinances of the City
of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other
ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction
documents and other data shall not prevent the Building Official from requiring the correction of errors in
the construction documents and other data.
5: ***MECHANICAL PERMIT CONDITIONS***
6: All mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila
Permit Center (206/431-3670).
PERMIT INSPECTIONS REQUIRED
Permit Inspection Line: (206) 438-9350
1800 MECHANICAL FINAL
0701 ROUGH -IN MECHANICAL
CITY OF TUKFW..- .
Community Development Department
Permit Center
• 6300 Southcenter Blvd., Suite 100
Tukwila, WA 98188
httt)://www.TukwilaWA.Pov
SITE LOCATION
Mechanical Permit No.
Project No.
Date Application Accepted: �Q
Date Application Expires: S — (0— 1
or o ce use only
MECHANICAL PERMIT APPLICATION
Applications and plans must be complete in order to be accepted for plan review.
Applications will not be accepted through the mail or by fax.
**please print**
/ King Co Assessor's Tax No.:�Wl o)LU()O)
Site Address: l'V,`t (1l Suite Number: Floor:
Tenant Name: 0.New Tenant: ❑ .....Yes R. o
PROPERTY OWNER - -�
Name: jOi N .1 n
Address:W55—V
CONTACT PERSON — person receiving all project
communication
Name:
Me
Addres 9- 1& S
City• State• Z'
Pho LA S ax:
Emai, •1Wtr CS
MECHANICAL CONTRACTOR I ORMATION
Company Name:
Address: QD S_
City. State: Zi q
Phon L Fax: ��'' ll
Contr Reg No. xp Date:
Tukwila Business License No.:
Valuation of project (contractor's bid price): $
Describe the scope of work in detail: I �'
Use: Residential: New ..........Replacement ........ ❑
Commercial: New .......... Replacement ........ ❑
Fuel Type: Electric..... ❑ Gas....... ❑ Other:
H:\Applications\Forms-Applications On Line\2016 ApplicationsWechanical Permit Application Revised 1-416.docx
Revised: January 2016
bh
Pagel of 2
M
Indicate type of mechanical work being installed and the quantity below:
Unit Type
Qty
Furnace <100k btu
Residential, Nighttime
Furnace >100k btu
Industrial
Floor furnace
55 dB(A)
Suspended/wall/floor
mounted heater
57 dB(A)
Appliance vent
Commercial
Repair or addition to
heat/refrig/cooling
system
47 dB(A)
Air handling unit
<I0,000 cfin
P
Unit Type
Qty
Air handling unit
>I0,000 cfm
Residential, Nighttime
Evaporator cooler
Industrial
Ventilation fan
connected to single duct
55 dB(A)
Ventilation system
57 dB(A)
Hood and duct
Commercial
Incinerator — domestic
47 dB(A)
Incinerator —
comm/industrial
P
Unit Type
Qty
Fire damper
Residential, Nighttime
Diffuser
Industrial
Thermostat
55 dB(A)
Wood/gas stove
57 dB(A)
Emergency enerator
Commercial
Other mechanical
equipment
47 dB(A)
60 dB(A)
P
Boiler/Compressor I Qty
0-3 hp/100,000 btu
3-15 h /500,000 btu
15-30 hp/1,000,000 btu
30-50 hp/1,750,000 btu
50+ hp/1,750,000 btu
Noise:
Mechanical units need to be in compliance with the Tukwila Noise Code. Maximum permissible sound levels are based on from where the sound is
created and where the sound is heard. Additionally, if sound can be heard from within a house at night in a residential zone it may not be allowed.
For more details, see TMC 8.22
District of Sound
Producing Source
District of Receiving Property
Residential, Daytime*
Residential, Nighttime
Commercial
Industrial
Residential
55 dB(A)
45 Q(A)
57 dB(A)
60 Q(A)
Commercial
57 dB(A)
47 dB(A)
60 dB(A)
65 dB(A)
Industrial
60 dB(A)
50 dB(A)
65 dB(A)
70 dB(A)
*Daytime means 7AM-IOPM, Monday through Friday and 8AM-IOPM, Saturday, Sunday and State -recognized holidays.
A few sounds are exempt from the noise code, including:
Warning devices;
Construction and property maintenance during the daytime hours (lam -I Opm);
Testing of backup generators during the day.
PERMIT APPLICATION NOTES -
Value of construction — in all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject
to possible revision by the permit center to comply with current fee schedules.
Expiration of plan review — applications for which no permit is issued within 180 days following the date of application shall expire by limitation.
The building official may grant one extension of time for additional periods not to exceed 90 days each. The extension shall be requested in writing
and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition).
I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER
PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT.
t,tty nate alp
H:\Applications\Forms-Applications On Line\2016 ApplicationsWechanical Permit Application Revised 1-4-16.docx
Revised: January 2016 Page 2 of 2
bb
DESCRIPTIONS
PermitTRAK
ACCOUNT
QUANTITY
PAID
$159.60
M16-0175 Address: 4550 5 134TH PL COMPLEX
Apn: 2613200005
$159.60
MECHANICAL
$153.46
PERMIT ISSUANCE BASE FEE
R000.322.100.00.00
0.00
$32.50
PERMIT FEE
R000.322.100.00.00
0.00
$90.27
PLAN CHECK FEE
R000.322.102.00.00
0.00
$30.69
TECHNOLOGY FEE
$6.14
TECHNOLOGY FEE
TOTALR9881
R000.322.900.04.00
0.00
$6.14
$159.60
Date Paid: Friday, November 18, 2016
Paid By: CONNIE HARDIN
Pay Method: CREDIT CARD 08116G
Printed: Friday, November 18, 2016 1:21 PM 1 of 1
N?SY57EM5
)e
X"
EXISTING GAS
UNIT HEATER A
u1 EN _ l 1 REPIL
CE J4.
' W i TEE
iE5
i �
400 (TW
TF�A€N'a~�s
!7�I� -
MEN
o �7hm � mil�u�upumuu ` _ �
J4N
---- - - -------
AY
......_
ttAL
I 1X4" t
%VIS'UNS +No ch i ! -
.. e STmade to thy! scopes -
Of lorl< with1--;prior approve of
OFFICE
i'�+`"rll Alii," i,!QrfnE
H� L Ux Y �A
v, 1s t".i r�.�;:!,� .! plate submittal
anJ m y in�'ude Ilddtionai plan reviel fees l!!_!' ':SON
Jae
he
ING GAS
HEATER
Plan
APA
the
of ao
_ _T LEVEL 1 HVAC PLAN
SCALE: 213T a T-0'
$TORAGE
__21a --
RELOCATED EXISTING
GAS UNIT (HEATER
EXISTING �RXEENHE
G-080-GEFAN
ON ROOF
FILE 41010PY
lrmit 0. t '
_0hq-_
Iw "�Ipnroval is sub ect to errors and of
of cansifuiaiion documen!s does not C
m of any adapted code or ordinance.
A
HOLADAr PARKS, INC
SMART Mechanical Solutiionsa
Mechanical Solutions . Energy Services
Building Controls . Service 8 Maintenance
4600 S. 134TH PLACE
SEATTLE, WA 98168. (206) 248-9700
aA?a T
� ? r w
J �'
I-
)e
X"
EXISTING GAS
UNIT HEATER A
u1 EN _ l 1 REPIL
CE J4.
' W i TEE
iE5
i �
400 (TW
TF�A€N'a~�s
!7�I� -
MEN
o �7hm � mil�u�upumuu ` _ �
J4N
---- - - -------
AY
......_
ttAL
I 1X4" t
%VIS'UNS +No ch i ! -
.. e STmade to thy! scopes -
Of lorl< with1--;prior approve of
OFFICE
i'�+`"rll Alii," i,!QrfnE
H� L Ux Y �A
v, 1s t".i r�.�;:!,� .! plate submittal
anJ m y in�'ude Ilddtionai plan reviel fees l!!_!' ':SON
Jae
he
ING GAS
HEATER
Plan
APA
the
of ao
_ _T LEVEL 1 HVAC PLAN
SCALE: 213T a T-0'
$TORAGE
__21a --
RELOCATED EXISTING
GAS UNIT (HEATER
EXISTING �RXEENHE
G-080-GEFAN
ON ROOF
FILE 41010PY
lrmit 0. t '
_0hq-_
Iw "�Ipnroval is sub ect to errors and of
of cansifuiaiion documen!s does not C
m of any adapted code or ordinance.
A
HOLADAr PARKS, INC
SMART Mechanical Solutiionsa
Mechanical Solutions . Energy Services
Building Controls . Service 8 Maintenance
COIC E COMPLiAr
- NEW RESTROOM APPROVED
EC 0 2 2016
UNDERCUT DOOR 1' _ V
11/18/16
No. Dale _�y Description
1 11/18/16 RL PERMIT ISSUE
CITY OF TUKWILA
NOV 18 2016
PERMIT CENTER
BUILDING DIVISION
.. ..... .. ..
=h'tlto •Ol7s
LEVEL 1 HVAC PLAN
M2.01
4600 S. 134TH PLACE
SEATTLE, WA 98168. (206) 248-9700
HOLADAYPARKS,com
WALICENSENUMBER HOLADPI379NO
J �'
I-
U)
v
Z
N)
w
W
J
v
r( cods f -d :Lt ,op = 20 (S
Y
0
�
00
�
=
W5 L, G a Kai Z.d (S 1 til
�e
�►�g a e, dw�-" Xk-)►kz0
14,00
�a
�u�e�Qrv(
0
�'
-
�;,
Q
o Y
RCPR WALL
TIMER
Z
'^
vJ
it FF --
TIMER TO OPERATE FAN
ITINUOUSLY DURING
:UPIED HOURS
Deaignea by:
` EXISTING
Drawn by
AOProvetl by:
Job Number.
43702
RESTROOM
COIC E COMPLiAr
- NEW RESTROOM APPROVED
EC 0 2 2016
UNDERCUT DOOR 1' _ V
11/18/16
No. Dale _�y Description
1 11/18/16 RL PERMIT ISSUE
CITY OF TUKWILA
NOV 18 2016
PERMIT CENTER
BUILDING DIVISION
.. ..... .. ..
=h'tlto •Ol7s
LEVEL 1 HVAC PLAN
M2.01
5/1/2017
City of Tukwila
Department of Community Development
CONNIE HARDIN
4600 S 134 PL
SEATTLE, WA 98168
RE: Permit No. M16-0175
PNW IRONWORKERS
4550 S 134 PL
Dear Permit Holder:
Allan Ekberg, Mayor
Jack Pace, Director
In reviewing our current records, the above noted permit has not received a final inspection by the City of Tukwila Building
Division. Per the International Building Code, International Mechanical Code, Uniform Plumbing Code and/or the National Electric
Code, every permit issued by the Building Division under the provisions of these codes shall expire by limitation and become null
and void if the building or work authorized by such permit has not begun within 180 days from the issuance date of such permit, or if
the building or work authorized by such permit is suspended or abandoned at any time after the work has begun for a period of 180
days. Your permit will expire on 6/4/2017.
Based on the above, you are hereby advised to:
1) Call the City of Tukwila Inspection Request Line at 206-438-9350 to schedule for the next or final inspection. Each
inspection creates a new 180 day period, provided the inspection shows progress.
-or-
2) Submit a written request for permit extension to the Permit Center at least seven(7) days before it is due to expire.
Address your extension request to the Building Official and state your reason(s) for the need to extend your permit.
The Building Code does allow the Building Official to approve one extension of up to 180 days. If it is determined that your
extension request is granted, you will be notified by mail.
In the event you do not call for an inspection and/or receive an extension prior to 6/4/2017, your permit will become null and void
and any further work on the project will require a new permit and associated fees.
Thank you for your cooperation in this matter.
Sincerely, A —W
��Vw
Bill Rambo
Permit Technician
File No: M16-0175
6300 Southcenter Boulevard Suite #100 • Tukwila, Washington 98188 • Phone 206-431-3670 • Fax 206-431-3665
PERMIT COOPD COPY
PLAN REVIEW/ROUTING SLIP
PERMIT NUMBER: M16-0175 DATE: 11/18/16
PROJECT NAME: PNW IRON WORKERS
SITE ADDRESS: 4550 S 134 PL
X Original Plan Submittal
Response to Correction Letter #
DEPARTMENTS:
0 (J X14 114
Building Division
Public Works ❑
PRELIMINARY REVIEW:
Not Applicable ❑
(no approval/review required)
REVIEWER'S INITIALS:
APPROVALS OR CORRECTIONS:
Approved ❑
Corrections Required ❑
(corrections entered in Reviews)
REVIEWER'S INITIALS:
Revision # before Permit Issued
Revision # after Permit Issued
6& J� %tw
Fire Prevention 10
Structural ❑
Planning Division ❑
Permit Coordinator 4
DATE: 11/22/16
Structural Review Required ❑
DATE:
DUE DATE: 12/20/16
Approved with Conditions ❑
Denied ❑
(ie: Zoning Issues)
DATE:
Permit Center Use Only
CORRECTION LETTER MAILED:
Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials:
12/18/2017
HOLADAY PARKS INC
Home Fspahol Contact
Safety & Health Claims & Insurance
Washington State Department of
kI Labor & industries
HOLADAY PARKS INC
Owner or tradesperson 4600 S 134TH PL
BECK, DAVID CARL SEATTLE, WA 98168
206-248-9700
Principals KING County
BECK, DAVID CARL, PRESIDENT
CONNELL, DANIEL A, PRESIDENT
GIRT, BIJIT, PRESIDENT
PIZZEY, GRACE K, VICE PRESIDENT
FREEL, JERRY LEE, VICE PRESIDENT
PARKS, GERALD T JR, PRESIDENT
(End: 08/12/2015)
NAILON, JUNE ANNETTE, VICE PRESIDENT
(End: 08/12/2015)
O'CONNOR, BONNY K, SECRETARY
(End: 08/12/2015)
BECK, DAVID CLARENCE, TREASURER
(End: 08/12/2015)
VAN DER VEEN, ERIC M, VICE PRESIDENT
(End: 08/14/2013)
PIZZEY, GRACE KATHERINE, VICE
PRESIDENT
(End: 08/14/2013)
VAN DER VEEN, JULIE
ELIZABETH, MEMBER
(End: 08/14/2013)
CONNELL, DANIEL AARON, MEMBER
(End: 08/14/2013)
GIRI, BUTT, MEMBER
(End: 08/14/2013)
KIEL, RINALD HOWARD, MEMBER
(End: 08/14/2013)
WHITMYRE, CHRISTIAN, MEMBER
(End: 08/14/2013)
NELSON, MICHAEL, SECRETARY
(End: 11/04/2010)
PARKS, DAVID L, TREASURER
(End: 11/04/2010)
TALBOT, PAUL, TREASURER
(End: 11/04/2010)
WA UBI No. Business type
578 004 089 Corporation
Page 1 of 3
Search L&I t1-1(tka
A -Z Index Help My L&I
Workplace Rights Trades & Licensing
Help us improve
https://secure.Ini.wa.gov/verify/Detail.aspx?UBI=578004089&LIC=HOLADPI379NO&SAW= 12/6/2016
HOLADAY PARKS INC Page 2 of 3
I License
Verify the contractor's active registration / license / certification (depending on trade) and any past violations.
Construction Contractor Active.
......................
Meets
Meets current requirements.
License specialties
Inspection results date
GENERAL
$1,000,000.00
License no.
Inspection no.
HOLADPI379NO
317940948
Effective — expiration
Effective date
01/21/1983— 09/03/2017
11101 /2016
Bond
.................
Expiration date
LIBERTY MUTUAL INS CO
$12,000.00
Bond account no.
23000452
Received by L&I
Effective date
08/23/2002
0910112002
Expiration date
Until Canceled
Insurance
Inspection results date
Charter Oak Fire Ins Co
$1,000,000.00
Policy no.
Inspection no.
DTCO1 F465357COF16
317940948
Received by L&I
Effective date
10131/2016
11101 /2016
Expiration date
11/01/2017
Insurance history
Savings
No savings accounts during the previous 6 year period.
Lawsuits against the bond or savings
No lawsuits against the bond oI.r savings accounts during the previous 6 year period.
L&I Tax debts
No C& tax'debts are recorded for this contractor license during the previous 6 year period, but some debts
may be recorded by other agencies.
License Violations
............i............ _....viola..............t....io....
No ns"* during the previous 6 year period.
Workers' comp
Do you know if the business has employees? If so, verify the business is up-to-date on workers' comp premiums.
L&I Account ID Account is current.
177,231-00
.................................
Doing business as
HOLADAY PARKS INC
Estimated workers reported
Quarter 3 of Year 2016 "Greater than 100 Workers"
L&I account representative
T2 / LESLIE QUNELL (360)902-5631 - Email: BAKY235@lni.wa.gov
Workplace safety and health
Check for any past safety and health violations found on jobsites this business was responsible for.
Inspection results date
09/22/2016
Under appeal. The results of the inspection are
Inspection no.
being challenged.
317940948
Date of appeal
Location
09/29/2016
1007 Stewart St
Seattle, WA 98101
Help us improve
https:Hsecure.Ini.wa.gov/verify/Detail.aspx?UBI=578004089&LIC=HOLADPI379NO&SAW= 12/6/2016