Loading...
HomeMy WebLinkAboutPermit M16-0176 - INSPIRUS CREDIT UNION - VRF SYSTEMINSPIRUS CREDIT UNION 5200 SOUTIACENTER BLVD M16=0176 City of Tukwila Department of Community Development * 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Inspection Request Line: 206-438-9350 Web site: http://www.TukwilaWA.eov MECHANICAL PERMIT Parcel No: 1157200013 Permit Number: M16-0176 Address: 5200 SOUTHCENTER BLVD Issue Date: 9/1/2017 International Residential Code Edition: Permit Expires On: 2/28/2018 Project Name: INSPIRUS CREDIT UNION 2014 Owner: 2015 Name: INSPIRUS CREDIT UNION 2014 Address: 5200 SOUTHCENTER BLVD, TUKWILA, 2015 WA, 98188 2015 Contact Person: 2015 Name: MATT LAASE Phone: (206) 324-4800 Address: 311 FIRST AVE S, SEATTLE, WA, 98104 Contractor: Name: PINCHIFF MECHANICAL LLC Phone: (206) 643-2046 Address: 650 S LUCILE ST, SEATTLE, WA, 98108 License No: PINCHML876PG Expiration Date: 10/7/2017 Lender: Name: Address: DESCRIPTION OF WORK: DEMOLITION OF ALL EXISTING PACKAGED ROOFTOP UNITS. INSTALLATION OF A NEW VRF SYSTEM FOR THE EXISTING AND EXPANSION PORTIONS OF THE BUILDING WITH OUTDOOR UNITS ON THE ROOF AND INDOOR UNITS IN THE CEILINGS. ENERGY RECOVERY VENTILATORS INSTALLED TO PROVIDE VENTILATION. Valuation of Work: $850,000.00 Fees Collected: $6,063.10 Type of Work: NEW Electrical Service Provided by: SEATTLE CITY LIGHT Fuel type: ELECT Water District: 125 Sewer District: TUKWILA Current Codes adopted by the City of Tukwila: International Building Code Edition: 2015 National Electrical Code: 2014 International Residential Code Edition: 2015 WA Cities Electrical Code: 2014 International Mechanical Code Edition: 2015 WAC 296-46B: 2014 Uniform Plumbing Code Edition: 2015 WA State Energy Code: 2015 International Fuel Gas Code: 2015 Date: Permit Center Authorized Signature: I hearby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this development perr9kand agree to the conditio js a tached to this permit. Signature: Print Name: L)A$c>-5 l/ 16kl Date: � 6 / /:7 This permit shall becoxhe null and void if the work is not commenced within 180 days for the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. PERMIT CONDITIONS: ***MECHANICAL PERMIT CONDITIONS*** All mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center (206/431-3670). All permits, inspection record card and approved construction documents shall be kept at the site of work and shall be open to inspection by the Building Inspector until final inspection approval is granted. PERMIT INSPECTIONS REQUIRED Permit Inspection Line: (206) 438-9350 1800 MECHANICAL FINAL 0701 ROUGH -IN MECHANICAL a. CITY OF TUKM. Community Development Department Permit Center • 6300 Southcenter Blvd., Suite 100 `y Tukwila, WA 98188 hU://www.TukmdlaWA.eov SITE LOCATION Mechanical Permit No. Project No. Date Application Accepted: Date Application Expires: or office use only) MECHANICAL PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. **please print** King Co Assessor's Tax No.. 1157200013 Site Address: 5200 Southcenter Blvd. Suite Number: Floor: Tenant Name: Inspiras Credit Union New Tenant: ❑ .....Yes ®..No PROPERTY OWNER Name: Inspirus Credit Union Address: 5200 Southcenter Blvd. City: Tukwila State: WA Zip: 98188 CONTACT PERSON — person receiving all project communication Name: Carol Cameron Address: 5200 Southcenter Blvd. City: Tukwila State: WA Zip: 98188 Phone: (206) 628-4088 Fax: Email: carol@inspiruscu.org Valuation of project (contractor's bid price): $ 850,000 Describe the scope of work in detail: MECHANICAL CONTRACTOR INFORMATION Company Name: TBD Address: City: State: Zip: Phone: Fax: Contr Reg No.: Exp Date: Tukwila Business License No.: Demolition of all existing packaged rooftop units. Installation of a new VRF system for the existing and expansion portions of the building with outdoor units on the roof and indoor units in the ceilings. Energy recovery ventilators installed to provide ventilation. Llse: Residential: New .......... ❑ Replacement ........ ❑ Commercial: New .......... 10 Replacement ........ Fuel Type: Electric ..... 0 Gas ....... ❑ Other:_ H:\Applications\Forms-Applications On Linc\2016 AppGeationsWecbmical Permit Application Revised 14-16.docx Revised: January 2016 Page 1 of 2 bh Indicate type of mechanical work being installed and the quantity below: Unit Type Qty Furnace <100k btu 4 Furnace >100k btu 40 Floor furnace 55 Suspended/wall/floor mounted heater 57 dB(A) Appliance vent Commercial Repair or addition to heat/refrig/cooling system 47 dB(A) Air handling unit .510 000 efm 65 dB(A) Unit Type Qty Air handling unit > 10,000 cfin 4 Evaporator cooler 40 Ventilation fan connected to single duct 55 Ventilation system 57 dB(A) Hood and duct Commercial Incinerator — domestic 47 dB(A) Incinerator — comm/industrial 65 dB(A) Unit Type Qty Fire damper 4 Diffuser 40 Thermostat 55 Wood/gas stove 57 dB(A) Emergency enerator Commercial Other mechanical equipment 47 dB(A) 60 dB(A) 65 dB(A) Boiler/Compressor LQty 0-3 hp/100,000 btu 4 3-15 hp/500,000 btu Industrial 15-30 hp/1,000,000 btu 55 dB(A) 30-50 hp/1,750,000 btu 57 dB(A) 50+ hp/1,750,000 btu Commercial 57 dB(A) 47 dB(A) 60 dB(A) 65 dB(A) Noise: Mechanical units need to be in compliance with the Tukwila Noise Code. Maximum permissible sound levels are based on from where the sound is created and where the sound is heard. Additionally, if sound can be heard from within a house at night in a residential zone it may not be allowed. For more details, see TMC 8.22 District of Sound Producing Source District of Receiving Property Residential, Daytime* Residential, Nighttime Commercial Industrial Residential 55 dB(A) 45 dB(A) 57 dB(A) 60 dB(A) Commercial 57 dB(A) 47 dB(A) 60 dB(A) 65 dB(A) Industrial 60 dB(A) 50 dB(A) 65 dB(A) 70 dB(A) *Daytime means 7AM-1 OPM, Monday through Friday and 8AM-1 OPM, Saturday, Sunday and State -recognized holidays. A few sounds are exempt from the noise code, including: Warning devices; Construction and property maintenance during the daytime hours (7am-1 Opm); Testing of backup generators during the day. PERMIT APPLICATION NOTES - Value of construction — in all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the permit center to comply with current fee schedules. Expiration of plan review — applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The building official may grant one extension of time for additional periods not to exceed 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER Print Name: Matt Laase AGENT: Mailing Address: 311 First Avenue South H:\Applications\Fomes-Applications On Line\2016 ApplicationsWechanical Permit Application Revised 14-16.docx Revised: January 2016 Date: 11/16/2016 Day Telephone: (206) 324-4800 Seattle WA 98188 City State Zip Page 2 of 2 DESCRIPTIONS ACCOUNT QUANTITY PAID PermitTRAK $4,494.96 M16-0176 Address: 5200 SOUTHCENTER BLVD Apn: 1157200013 $4,365.17 MECHANICAL $4,157.30 PERMIT ISSUANCE BASE FEE R000.322.100.00.00 0.00 $32.50 PERMIT FEE R000.322.100.00.00 0.00 $4,124.80 TECHNOLOGY FEE $207.87 TECHNOLOGY FEE R000.322.900.04.00 0.00 $207.87 PG17-0109 Address: 5200 SOUTHCENTER BLVD 230 Apn: 1157200013 $129.79 PLUMBING $129.79 PLAN CHECK FEE RECEIPT:TOTAL FEES PAID BY R000.322.103.00.00 0.00 $129.79 $4,494.96 Date Paid: Friday, September 01, 2017 Paid By: PINCHIFF MECHANICAL Pay Method: CHECK 3987 Printed: Friday, September 01, 2017 1:59 PM 1 of 1 rRSY57EM5 AOW DESCRIPTIONS PermitTRAK ACCOUNTQUANTITY PAID $12,486.57 D16-0317 Address: 5200 SOUTHCENTER BLVD Apn: 1157200013 $8,255.43 DEVELOPMENT $8,005.43 PLAN CHECK FEE R000.345.830.00.00 0.00 $8,005.43 PUBLIC WORKS ' $250.00 BASE APPLICATION FEE R000.322.100.00.00 0.00 $250.00 D16-0318 Address: 5200 SOUTHCENTER BLVD Apn: 1157200013 $1,535.04 DEVELOPMENT $1,535.04 PLAN CHECK FEE R000.345.830.00.00 0.00 $1,535.04 EL16-1064 Address: 5200 SOUTHCENTER BLVD Apn: 1157200013 $889.79 ELECTRICAL $889.79 PLAN CHECK FEE R000.345.832.00.00 0.00 $889.79 M16-0176 Address: 5200 SOUTHCENTER BLVD Apn: 1157200013 $1,697.93 MECHANICAL $1,697.93 PLAN CHECK FEE R000.322.102.00.00 0.00 $1,697.93 PG16-0169 Address: 5200 SOUTHCENTER BLVD Apn: 1157200013 $108.38 PLUMBING $108.38 PLAN CHECK FEE TOTALPAID .9894$12,486.57 11000.322.103.00.00 0.00 $108.38 Date Paid: Monday, November 21, 2016 Paid By: INSPIRUS CREDIT UNION Pay Method: CHECK 0002215980 Printed: Monday, November 21, 2016 2:08 PM 1 of 1 INSPECTION RECORD Retain a copy with permit / 0/77 INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Project: /YSP�Rptr <'RBpiT it/i0 Type of Inspection: /nJfehVW109'- A-'1*174 Address: 5zc� �ovrrfc'�N�R �u10 Date Called: Special Instructions: Date Wanted: a.m. 6 -29 /g) P.M. �/ry�„dC,P /C<1144 7— Requester: ,V?t L Phone No: MAppmved per applicable codes. LJ Corrections required prior to approval. COMMENTS: lnspector: �jE <1 IDate: Ile a?,/g REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. INSPECTION RECORD Retain a copy with permit I 141 (D -017X, INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Project: Type of Inspection: t rrti e ca, : I Date led: ,tD Special In uctiio'_ns: Date anted: m. 41? SLI Requester: Phone No: Approved per applicable codes. t_J Corrections required prior to approval. IInspector: /< X/ / _ IDate: / _ O —.;?04 REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. INSPECTION RECORD Retain a copy with permit L b' 01% INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Project: P e of Inspection: lb .r ddres r. Date C ed: Special Instructions: Date Wanted an d0—ID .m. 0—ID Requester: n Zi C. Ph n� REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. 9 INSPECTION RECORD Retain a copy with permit M INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Approved per applicable codes. ACorrections required prior to approval. REINSPECTION FEE REQUIRED. Prior to next inspection, flee must be paid at 6300 5outhcenter Blvd., Suite 100. Call to schedule reinspection. Z INSPECTION RECORD /- Retain a copy with permit Im (9 " 017 INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Approved per applicable codes. LJ Corrections required prior to approval. Inspector: Date: 5' 3a • TeIF REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. INSPECTION RECORD Retain a copy with permit M16 -0176 INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Project: 4 a of Inspection: V` A0 'dr� � 5f•W 4 &- BLVA Date Ca d: Special IInnstructions:��7T� a.m. Date Wanted:�� P.M. — 20 45 Requester: prior.Phone No* s El REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call, to schedule reinspection. INSPECTION RECORD M Retain a copy with permitFm I i o1 76 INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Project: M45 ► a of In pection: r - -e 1 Address. �o d Date C ed: Special Instructions: v cc �J r /✓ 4� Date Wanted: (fa.m. ^�1ff P.M. Requester: � Ey-IC- PhNo: one �L p I OApproved per applicable codes. El Corrections required prior to approval. tOMMENTS: OT -- 1 / YA'� -- - r �1wl.moi'NET ri N WA I r, El REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Calt to schedule reinspection. INSPECTION RECORD Retain a copy with permit M 16 7-,1 , INSPECTION N0. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Projec�t'"���� / � s Oncd';L Type of Inspection: � s, c..l-ftC� /ice ' ._ c."Ic Address: Zoa 8W Date Call . Special Instructions: Date Wanted:a. 3 Z 0/8, P.m. Requester: 11 ,6r 1 C Phone No: Approved per applicable codes. 11 Corrections required prior to approval. W71FA HIP Val U REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. INSPECTION RECORD Retain a copy with permit JM-6)7�1 INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Project: Type of Inspe tion: 0 Address: I 200 S LVA Date Called: 3- - 7� Special Instructions: Date Wanted: 63 -) z �A% P.M. Requester: Phone No: 11 Approved per applicable codes. Corrections required prior to approval. nspecto z_ REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Calt to schedule reinspection. 0- 2015 Washington State Energy Code Compliance Forms for Commercial, R2 and R3 over 3 stories and all R1 Mechanical Summary MECH-SUM 2015 Washington State Energy Code Com liance Forms for Commercial Buildings including R2 & R3 over 3 stories and all R1 Revised October 2016 Project Title: Inspirus Credit Union Expansion Date 11/15/2016 Do G n FORMS MlS Applicant Information. Provide contact information for individual who can respond to inqumes about compliance form information provided. For Building Dept. Use Company Name: Matrix Engineers Do Not Uw Aftw Company Address: 725 Powell Ave SW, Suite 100 Renton, WA 98057 ��II��,,�,.� �tml1YJQ."+f any 2X6 Applicant Name: Scott Miller Applicant Phone: 206.920-9240 U Project Description ❑ New Building Q Building Addition ❑ Tenant Improvement Q System Retrofit ❑ No System Changes Briefly describe mechanical systems in the text box provided ❑ Total Bldg Performance Total Bldg Performance compliance includes all mandatory provisions per C401.2 Option 2. MECH-SUM, MECH-CHK, and C407 Energy Analysis Summary fora required. ❑✓ Load calculation summary ❑ MECH-LOAD-CALC Form Design Load Calculations Provide design load calculations forall mechanical systems and equipment serving the building heating, cooling or ventilating needs. If a load calculation summary is provided with the permit documents that includes all applicable compliance information then the MECH-LOAD-CALC form is not required. E] Mechanical Plans ❑ MECH-EQ Forms Mechanical Schedules Indicate location of equipment compliance information. If provided on plans then MECH-EQ forms are not required, however, include on plans all applicable compliance information listed in MECH-EQ tables. ❑ DOAS Required for C402A.1.4 credit Requires all conditioned floor area to be served by C403.6 compliant DOAS system with heating and cooling system fans cycled off when no heating or cooling is required. Dedicated Outdoor Air ❑ DOAS Required for C403.3.1,exception 1 System Requirements y q Requires all floor area served by equipment applying C403.3.1, exception 1 to have C403.6 compliant DOAS system with heating and cooling system fans cycled off when no heating or cooling is required. ❑ DOAS Required by C403.6 (starling July 1, 2017 in specifed building types) Requires 90% of conditioned floor area to be served by C403.6 compliant DOAS system with heating and cooling system fans cycled off when no heating or cooling is required, or by C403.7 HP VAV system ❑� Project includes HVAC air distribution systems that provide heating and/or cooling If yes, provide a MECH-FANSYS -SUM form. Fan Power ❑ For one or more systems, the total fan motor nameplate hp of all fans in HVAC system exceeds Shp. If yes, provide a separate MECH-FANSYS form for each HVAC system exceeding the 5 horsepower threshold. Refer to Section C403.2. 10 and MECH-FANSYS-DOC for requirements and exceptions. ❑ Hydronic chilled water ❑ Water -bop heat pump ❑ No hydronic systems HVAC Hydronic Systems ❑ Hydronic heating ❑ Geothermal ❑ C406.2 High Efficiency Mechanical Requires 90% of heating and cooing capacity to be equipment listed in tables C403.2.3(1)-(9) or air -to -water heat pumps and heat recovery chillers. All equipment listed in tables C403.2.3(1)-(7) must be 15% more efficient than 0406 Additional minimum requirements. All standalone supply, retum, and exhaust fans over 1hp must have FEQ a 71 and must be selected within 100% of maximum total or static pressure. Efficiency Options - ❑ 0406.6 Dedicated Outdoor Air hie Requires 90% of conditioned floor area to be served by C403.6 complaint DOAS with heating and cooling system E an a FOR fans cycled when no heating or cooling is required. ❑ C406.7 Reduced energy in service water heating XCOMPLIANCE Requires 90% of floor area be in occupancy types listed in C406.7. I and that 60% of annual hot water energy use be 82212 ED provided by heat pump, waste heat recovery or solar water -heating systems. DEC 0 6 2016 City of Tukwila BUILDING DIVISI a RECEIVED CITY OF TUKWILA NOV 212016 PERMIT CENTER 2015 Washington State Energy Code Compliance Forms for Commercial, R2 and R3 over 3 stories and all R1 Mechanical Summary, •• 2015 Washington State Energy Code Compliance Forms for Commercial Buildings including R2 & R3 over 3 stories and all R1 Revised October 2016 Equipment Type (s) ❑ Hot water heating tank(s) ❑ Instantaneous Q No service water systems Service Water Heating Systems ❑ Heat exchange from heat (boiler or s El Dedicated boiler g p central hot water/steam Distribution Type (s) ❑ Circulation System ❑ On -demand Commissioning Exception ❑✓ Commissioning will be provided for all applicable systems Summary Commissioning Exceptions: Describe means of eligibilty for commissioning exception (capacity Mechanical system(s) etc) for all systems noted as taking exception in Mechanical Systems Summary table. Refer to Section C408.2 and C408.4 for exceptions. ❑ Service water heating system(s) For systems requiring commissioning, Figure C408.1.2.1 Commissioning Compliance Checklist shall be submitted to the code official upon project completion. Low Energy and Semi -Heated Spaces (Note 6 and 7) Peak Space Heating Cooling Conditioning Space Area Served, Capacity, Btu/h Capacity, Btu/h Capacity, Compliance Type Location in Plan(s) Space(s) Served square feet (Note 4) (Note 5) Btu/h-sf Check Notes Note 4 - Provide total installed heating output capacity of systems serving Low Energy or Semi -Heated space(s) in btuh. Note 5 - Provide total installed cooling capacity of system senting Low Energy space(s) in Btu/h. Not allowed for semi -heated spaces. Enter 0 if no cooling. Note 6 - Refer to Section C 101.5.2 Low Energy Building. Intalled peak space conditioning capacity, heating or cooling, may not exceed 3.4 Btu/h-sf. Note 7 - Refer to Section C402.1.4 and Semi -Heated Space definition in Chapter 2. Total heating output capacity may not exceed 8 btuh/sf. Only systems without electric resistance heating and no cooling are eligible for the wall insulation exception under semi -heated. 1 2015 Washington State Energy Code Compliance Forms for Commercial, R2 and R3 over 3 stories and all R1 - Page 1 of 7 Mechanical Permit Plans Checklist MECH-CHKI 2015 Washington State Enerav Code Compliance Forms for Commercial Sulldinas includino R2 A R3 over 3 stnries and all R1 14a 1—ef nMnhar gni a Project Title: Inspirus Credit Union Expansion Date 11/15/2016 The following information is necessary to check a permit application for compliance with the mechanlcial systems and equipment requirements of the Washington State Energy Code, Commercial Provisions. D ° o 7 FOO RM's D@ HM MM After o efmp 31,o Was Appl—late /yes,no,na) Code Section Code Provision Information Required - Must he In permit documents Location in Building Department Documents Notes Equipment - Sizing, Performance and Type Identify equipment to be used in manufacturing, industrial or commercial processes that do not no C403.1 Exempt process equipment provide space conditioning; Identify provisions applicable to this equipment per C403.1 exception Provide load calculations performed per ASHRAE Std 183 or equivalent, using design attached yea C403.2.1 Load calculations parameters per C302 and Appendix C; include load adjustments to account for energy recovery Equipment and system Indicate that output capacities of heating and cooling equipment and systems are no greater M002 yea C403.2.2 than the smallest available equipment size that exceeds the calculated loads; note exceptions sizing taken C403.2.3 HVAC equipment Provide equipment schedules on plans or complete MECH-EQ forms indicating type, capacity, M002 yes C403.2.3.2 performance requirements rated and WSEC minimum efficiencies for all heating and cooling equipment; Include supply C403.2.13.1 (efficiency) and OSA cfms and operating hours for all air systems; identify heating and cooling equipment that does not have a corresponding WSEC minimum efficiency (manufacturer rated) List a1 motors k 1/12 hp (that are not integral to a rated piece of equipment) in the mechanical C405.8 or electrical equipment schedules on plans; indicate hp, rpm, number of poles and rated no C403.2.14 Electric motor efficiency efficiency, or exception applied For fractional hp motors (1/12 - 1 hp), Indicate whether they are an electronically commutated motor, have rated efficiency of at least 70%, or exception taken For all HVAC fan systems that provide heating and / or cooling, provide system total nameplate hp in MECH-FANSYS-SUM form no C403.2.11.1 Fan power limitation For all applicable HVAC systems with total fan motor hp > Shp, verify fan system motor hp or bhp complies with fan power limits per equations in Table C403.2.11.1(1), provide MECH- FANSYS form for each system no C403.2.11.2 Motor nameplate hp For all applicable HVAC systems with total fan motor hp > Shp, Indicate fan motors specified are the smallest available motor hp size greater than fan bhp, note exceptions taken For all applicable HVAC systems with total fan motor hp > Shp, identify in equipment schedule no C403.2.11.3 Fan efficiency all fans required to comply with fan efficiency grade and indicate rated FEG Is 2 67, or exception taken; indicate these fans are sized so total efficiency Is within 15% of the fan maximum total efficiency no C403.2.11.4 Group R occupancy exhaust For all exhaust fans < 400 cfm In Group R occupancies, indicate in equipment schedule the fan efficacy fan flow rate and efficacy (chnMratt), or exception taken; refer to Table C403.2.11.4 (CE -57) Variable flow capacity - For fan motors 2 7.5 hp, indicate method of variable flow control (VSD or equivalent method) in no C403.2.13 fans equipment schedule, or exception taken; for equivalent method for an HVAC system refer to HVAC System Controls for additional requirements no C403.2.3 Maximum air cooled chiller For chilled water plants and buildings with > 500 tons of cooling capacity, indicate air-cooled capecity chiller capacity Is s 100 tons, or exception taken Large capacity cooling For buildings with 2 300 tons of cooling capacity, indicate method of multi -stage or variable no C403.4 systems capacity control (VSD, multiple staged compressors, or max capacity of any single unit < 66% of the total) Non-standard water-cooled For water-cooled centrifugal chillers not designed for operation at standard conditions, provide no C403.2.3.1 centrifugal chillers calculations documenting maximum full load and part load rated equipment performance requirements C403.2.13.1 Centrifugal fan open-circuk For open -circ uft centrifugal fan cooling towers with a 1,100 gpm capacity, indicate cooling no C403.4.3.2 cooling towers towers comply with efficiency requirements for axial fan open circuit cooling towers For single boilers with > 500,000 BbA capacity, indicate multi -stage or modulating burner no C403A.2 . Large capacity boiler For boiler system (single or muMple) with > 1,000,000 Btu/h capacity, indicate turndown ratio C403.4.2.5 systems per Table C403.4.2.5 and method (multiple single input boilers, modulating boilers, or combination) Variable flow capacity - For pump motors 2 7.5 hp, indicate method of variable flow control (VSD or equivalent no C403.2.13 method) in equipment schedule, or exception taken; for equivalent method for a hydronic pumps system refer to Hydronic System Controls for additional requirements no C403.2.3 Gas and oilfired forced air For forced air furnaces with capacity 2 225,000 Btulh and all unit heaters, indicate in furnace and unit heaters equipment schedule intermittent ignition or IID, flue or draft damper, and rated jacket loss no C403.2.4.8 Combustion heating For combustion heating equipment with output capacity > 225,000 Btu/h, indicate modulating equipment or staged combustion control no C403.2.3.3 Packaged electric heating / Verify all packaged electric equipment with > 6,000 Btu/h cooling capacity and any amount of cooling equipment heating is a heat pump; include in equipment schedules no C403.2.12 Heating outside a building Indicate systems providing heating in non -enclosed outdoor occupied spaces are radiant systems; refer to HVAC System Controls for additional requirements no 0403.2.7.1 Kitchen exhaust hoods Indicate on plans the type, duty and exhaust air rate of each kitchen hood, refer to HVAC System Controls for additional requirements Outdoor supply air, exhaust Indicate locations of OSA intake, and exhaust and relief outlet dampers on plans; indicate M202 yes C403.2.4.3 and relief dampers whether dampers are Class 1 motorized, or gravity and exception taken (Include leakage rating, chn/sf); refer to HVAC System Controls for additional requirements for OSA dampers ' 2015 Washington State Energy Code Compliance Forms for Commercial, R2 and R3 over 3 stories and all R1 - Page 2 of 7 2015 Washington State Enerav Code Corroliance Forms for Commercial Buildings inciudina R2 & R3 over 3 stories and all R1 Revised October 2016 Project Title: Inspirus Credft Union Expansion Date 11/15/2016 The following information is necessary to check a permit application for compliance with the mechanicial systems and equipment requirements of the Washfngton State Energy Code, Commerclaf Provisions. ®° � �Oo G°3 i1� a f�0� NJ� Q cep ©c �o�MT 39,9 206 Applicable Code Section Code Provision Information Required - Must be In permit documents Location in Building Department (yes,no,na) Documents Notes Indicate locations of return air dampers that are integral to economizer operation; verify no C403.2.4.3 Return air dampers dampers are motorized; indicate whether dampers are Class 1, or within packaged equipment eligible for leakage rating exception (include leakage rating, cfm/sf) C403.2A.3 Stairway and shaft vent Indicate location of stairway and shaft vent dampers on plans; verify dampers are Class 1 no dampers motorized; refer to HVAC System Controls for additional requirements For systems serving areas > 25,000 of or spanning more than one floor, that include areas that no 0403.2.4.4 Zone isolation dampers are expected to be occupied non -simultaneously; identify Isolation zone areas on plans and locations of associated isolation dampers in HVAC distribution system; refer to HVAC System Controls for additional requirements For cooling systems with humidification equipment that are also required to have air no C403.2.3.4 Humidification economizer, indicate humidifier is adiabatic (direct evaporative or fog atomization), or exception taken Additional Efficiency Package Option, More Efficient HVAC Equipment & Fan Performance - Must comply with all 3 provisions to be eligible 0406.2.1 To comply with additional efficiency package option, calculate the percentage of heating and C403.2.3 HVAC system selection cooling equipment in the project (based on output capacity) that do not have a corresponding WSEC fisted efficiency; shall be less than 10% to comply C406.2.2 Minimum equipment To comply with additional efficiency package option, indicate that all listed heating and cooling C403.2.3 efficiency equipment have a rated efficiency that exceeds WSEC listed efficiency by at least 15% C406.2.3 To comply with additional efficiency package option, Indicate rated FEG of stand alone fans is C403.2.11.3 Minimum fan efficiency 2 71; indicate these fans are sized so the fan efficiency at design conditions Is within 10% of the maximum total or static efficiency HVAC Lystem Controls Indicate locations of thermostatic and humidity control devices and the zones they serve on M201 fans, Including perimeter system zones M201 Where adjacent (neighboring) zones are controlled by separate thermostats (including perimeter systems used to offset heat gain or loss), and are connected by permanent Thermostatic controls openings > 10% of either zone at area, indicate controls configured to prevent adjacent zones yes C403.2.4.1 (thermostats and from operating in conflicting modes (one In heat, other in cool); applies to adjacent perimeter humidistats) zones, adjacent nonperimeter zones, and adjacent perimeter and nonperimeter zones If applying Exception 2 to nonperimeter zones adjacent to perimeter zones, indicate that M201 setpoints and deadband settings in these zones are coordinated so cooling in a nonperimeter zone does not occur until the temperature In that zone Is 5°F higher than the adjacent perimeter zone temperature In heating C403.2.4.1.1 Heat pump supplementary Indicate staged heating operation with compression as the first stage of heating and no heat supplemental heating controlled with outdoor lockout temperature set to 40°F or less Yes C403.2.4.1.2 Deadband Indicate zone thermostatic controls configured with 5°F minimum deadband for systems that M001 control both heating and cooling If separate heating and cooling systems with separate thermostatic control devices are used to Setpoint overlap restriction serve a zone, indicate locations of both thermostatic control devices and the zone they serve no C403.2.4.1.3 (thermostats) on plans Indicate a Emit switch, mechanical stop or DDC control with programming to prevent simultaneous heating and cooling C403.2.4.2 Automatic setback and Indicate zone thermostatic controls configured with required automatic setback and manual M002 yes C403.2.4.2.1 shutdown override functions, setback temperatures, and control method (automatic time dock or 0403.2.4.2.2 programmable controls); note exceptions taken yes 0403.2.4.2.3 Automatic (optimum) start Indicate system controls that adjust equipment start time required to bring each area served just M001 up to design temperature prior to scheduled occupancy yes 0403.2.4.3 Outdoor supply air dampers Indicate automatic controls configured to dose OSA damper during unoccupied equipment M201 operation; not including economizer cooling, night flush or IMC required OSA / exhaust no C403.2.4.3 Stairway and shaft vent Indicate method of activation of stairway and shaft vent dampers (fire alarm or interruption of dampers power For systems serving areas > 25,000 at or spanning more than one floor, that include areas that no C403.2.4.4 Zone isolation controls are expected to be occupied non-simuttaneously; indicate controls that allow for independent space conditioning of Isolation zones; or exception taken no C403.2.12 Heating outside a building Indicate occupancy sensing or timer switch controls configured to automatically shut off heating system when area served is unoccupied no 0403.2.4.5 Snow melt systems Indicate automatic controls configured to shut off system when pavement temperature exceeds 50°F and no precipitation Is falling, and when outdoor air temperature exceeds 40°F 0403.2.4.6 Freeze protection system Indicate automatic controls to shut off system when outdoor temperature exceeds 40°F, or no controls conditions protect fluid from freezing Group R1 hotel / motel For hotels and motels with over 50 guest rooms, indicate automatic controls serving guest no C403.2.4.9 guest rooms rooms that are capable of setback (heating) and set-up (cooling) of tempurature setpoint by at least 5°F; indicate control method- activated by room entry or occupancy sensor 2015 Washington State Energy Code Compliance Forms for Commercial, R2 and R3 over 3 stories and all R1 - Page 3 of 7 2015 Washington State Energy Code Compliance Forms for Commercial Buildings including R2 & R3 over 3 stories and all R1 Revised October 2016 Project Title: Inspirus Credit Union Expansion Date 11/15/2016 The following Information is necessary to check a permit application for compliance with the mechanicial systems and equipment requirements of the Washington State Energy Code, Commercial Provisions. D ° l BOO G°3�u113 a �Io� M�� Q cep ��OSp 31'0 �0�6 P pptkcable Code Section Code Provision Information Required - Must be /n permit documents --]Location in Building Depamnent (yes,no,na) Documents Notes C403.2.4.10 Group R2 / R3 dwelling For primary space conditioning system, Indicate 5-2 programmable thermostats capable of two no C403.2A.11 units, Group R2 sleeping setback periods per day; for all thermostats indicate purpose (heating only, cooling only, or units both), required temperature range and at minimum a 10'F deadband; or exception taken Indicate method of ventilation arc delivery (natural or mechanical) for each zone M201 If mechanically delivered, indicate that systems are configured to provide not more than 150% M201 Yes C403.2.6 C403.2.11.4 Ventilation of, but at least the minimum required volume of outdoor air to each zone per IMC, ASHRAE 62.1 or other applicable code AC, OSHA, etc); or exception taken If delivered via natural ventilation, Identify required elements per IMC Including minimum openable area to the outdoors or quarrfAng adjoining spaces Identify spaces > 500 of with occupant load > 25 people/1,000 at per IMC; for each space Demand controlled Indicate whether it is served by an HVAC system with total design OSA > 3,000 dM, and / or no C403.2.6.2 ventilation the system has airside economizer or automatic modulating OSA damper, indicate OSA controls are configured to provide demand controlled ventilation or provide supporting documentation for applied exception For gyms, classrooms, auditoriums and conference rooms > 500 sf, indicate occupancy -based no C403.2.6.3 Occupancy sensors OSA control when space is unoccupied and method (doses OSA damper or shuts -off equipment); or aftemate means provided to automatically reduce OSA when space Is partially occupied C403.2.6.4 Enclosed loading dock For enclosed loading docks, indicate ventilation / exhaust system method of activation (gas no C403.2.6.4.1 ventilation detection system for CO and NO2, or occupancy sensors), and control method (staged or modulating) C403.2.6.4 Enclosed parking garage For enclosed parking garages, indicate ventilation / exhaust system activated by gas detection no C403.2.6.4.2 ventilation system for CO and NO2, and control method (staged or modulating); or exception taken Provide calculations that show a balanced accounting of total kitchen exhaust (include all hoods) with % of supply air, transfer air from adjacent spaces, and make-up air, if applicable, no C403.2.7.1 Kitchen exhaust hoods indicate that direct make-up air to each hood does not exceed 10% of hood exhaust For kitchens with total hood exhaust exceeding 2,000 cfm, indicate exhaust air rate per Table C403.2.7.1 and compliance method (DCV, energy recovery, or transfer air that would otherwise be exhausted) no C403.2.7.2 Laboratory exhaust systems Refer to Systems Requiring Energy Recovery for requirements Variable flow capacity - For HVAC fan motors 2 7.5 hp, indicate method of variable flow control (VSD, or equivalent no C403.2.13 HVAC system fans control method that reduces design air volume by 50% at 1/3 static design pressure); note exception taken DX air handler variable For DX air handlers with economizer and cooling capacity 2 65,000 Btu/h, indicate number of cooling control cooling stages provided and method (multiple compressors and / or variable speed no C403.3.1 (Under Integrated compressors); indicate minimum displacement (capacity reduction as % of full load Indicate control method (cooling capacity controlled in response to space temperature, space Economizer) temperature controlled by modulating supply airflow, or both For DX air handling units with cooling capacity k 65,000 Btulh and evaporative and chilled water air handling units with fan 2 0.25 hp, indicate whether system is single zone or multiple zone and related control method (cooling capacity controlled in response to space temperature, space temperature is controlled by modulating supply airflow, or both) For mechanical cooling systems (includes DX and chilled water coils) that control cooling capacity in response to space temperature - Provide a minimum of two stages of fan control; no C403.2.11.5 Fan airflow control indicate minimum fan speed Is15 66% of full speed drawing 5 40% of full speed fan power during periods of low cooling or ventilation only For other mechanical cooing systems (includes DX and chilled water coils) that control space temperature by modulating airflow (in lieu of, or in addition to, controlling capacity in response to space temperature) - Provide fan controls for modulating supply airflow, Indicate minimum fan speed is 5 50% of full speed drawing 5 30% of full speed fan power during periods of low cooling or ventilation only, or exception taken Provide central and zone level DDC controls as required based on system application, yes 0403.2.4.12 DDC system capabilities ce a or size thresholds and other uallficetion per Table 0403.2.4.12.1 M002 Identify all DDC system input / output control points; indicate capability for trending and graphical display M002 Ducting Systems C403.2.8.1 Indicate on plans that all ductwork is constructed and sealed per IMC M001 For OSA ductwork, also indicate on plans that ductwork meets air leakage requirements per yes 0403.2.8.3 Dud construction 0402.5 and vapor retarder requirements per the IBC MOM yss C403.2.8.3 Duct pressure classifications Identify location of low, medium and high pressure ductwork on plans M001 C403.2.8.3.3 High pressure duct leakage Indicate high pressure duct leakage testing requirements on plans; provide test results to na test 1jurisdiction when completed ` 2015 Washington State Energy Code Compliance Forms for Commercial, R2 and R3 over 3 stories and all Rl - Page 4 of 7 2015 Washinaton State Enerov Code ComDliance Forms for Commercial Buildinas including R2 & R3 over 3 stories and all R1 Revised October 2016 Project Title: Inspirus Credit Union Expansion Date 11/15/2016 The following information Is necessary to check a permit application for compliance with the mechanicial systems and equipment requirements of the Washington State Energy Code, Commercial Provisions. D ° G COG°3�iil� o a �lo� M Qc�p U�6��f�Qr,' ��o p©l6 4phcabte Code Section Code Provision Information Required - Must be in permit documents Location in Building Department (yes,no,na) Documents Notes For supply and return ductwork located in unconditioned space or outdoors, indicate R -value of insulation on ductwork onplans; Identify climate zone; note exceptions taken M0ol For supply ductwork located in conditioned space, identify if design supply temperature Is < C403.2.8.1 Yes 0403 2 8 2 Duct insulation 55°F or> 105°F and indicate R -value of insulation on this ductwork on plans; note exception taken M001 For OSA ductwork, shafts and plenums, Indicate R -value of insulation on these elements on fans per Table C402.1.3 for steel --framed wails; note exception taken Imool Piping Systems yes 0403.2.9 Piping insulation Indicate design temperature range of fluid conveyed to piping and thickness of insulation (in inches) on h dronic piping plans; or exception taken Pool C403.2.9.1 Piping insulation exposed to Indicate method of protection of pipe insulation from damage / degradation on hydronic piping no weather plans Economizers Identify in equipment schedules on plans or in MECH-EQ forms all cooling systems requiring air economizer controls Provide MECH-ECONO form indicating systems utilizing air economizer exceptions, including no 0403.3 Air economizer required those with water -side economizer in lieu of air economizer, indicate on plans eligible exception(s) taken and measures to comply with exception(s) 0403.3.1 Integrated economizer Indicate arc and water-skle economizers are configured for partial cooling operation even no operation - air and water where additional mechanical cooling is required to meet the load no C403.3.2 Economizer heating system Verify control method of HVAC systems with economizers does not increase building heating impact - air and water energy usage during normal operation no C403.3.3.1 Air economizer capacity Indicate modulating OSA and return arc dampers are configured to provide up to 100% OSA for cooling Verify mechanical cooling controls are interlocked with air economizer controls so the outside C403.3.1 air damper remains in 100% open position when mechanical cooling is also required to meet no C403.3.3.2 Integrated air economizer the coolingload, until the leaving air temperature Is < 45°F For systems with cooling capacity 2 65,000 BUM, verify that control of economizer dampers is not based on on mixed air temperature; or exception taken no C403.3.3.3 Air economizer high limit controls Indicate high knit shutoff control method and required high limit per Table C403.3.3.3 For eligible systems where water -side economizer may be provided in lieu of air economizer, no C403.3.4.1 Water economizer capacity indicate system Is capable of 100% design coding capacity at 50°F db / 45°F wb OSA temperatures no 0403.3.4.2 Water economizer Indicate pressure drop across precooing coils and heat exchangers in water economizer maximum pressure drop system do not exceed pressure drop limit C403.3.1 DX air handling equipment For DX air handlers with economizer and cooling capacity 2:65,000 Btu/h, refer to HVAC no control System Controls for requirements DX equipment economizer For DX air handlers with economizer and cooling capacity 2 54,000 Bttr/h, provide a faun no C403.2A.7 fault detection and detection and diagnostics (FDD) system to monitor economizer system operation and report diagnostics faults Systems Requiring Energy Recovery For systems with design OSA > 5,000 cfm, or design supply air cfm and % OSA exceeding the values in Tables C403.5.1(1) or (2), indicate exhaust air ER method; or exception taken with supporting calculations Energy recovery - For rooms served by multiple systems with aggegate design OSA > 5,000 afm, or aggregate no 0403.5.1 t /exhausstt systems systeemsms design supply air cfm and % OSA exceeding the values in Tables G403.5.1 (1) or (2), indicate exhaust air ER method; or exception taken with supporting calculations Indicate ER rated effectiveness that increases OSA enthalpy by a 50% based on delta between OSA and return air enthalpies at design conditions Laboratory exhaust systems For buildings with total lab exhaust > 5,000 cfm, indicate method of energy recovery used to no C403.2.7.2 (energy recovery) c preondition laboratory make-up air, ER effectiveness (min 25°F); or altemative method per exception (VAV exhaust, semi -conditioned makeup, or CERM calculation) For buildings with pools or spas with water surface area > 200 sf, indicate exhaust air ER C404.10.4 Pools and permanent spas method and use of waste heat (preheat ventilation air, pool water or service hot water); or no (under exhaust systems exception taken C404.11) (energy recovery) Indicate ER system has the rated effectiveness and is configured to decrease the exhaust air temperature at design conditions by 2 36°F Energy recovery - For buildings with on-site steam heating systems, indicate condensate water ER For buildings that use off-site generated steam where condensate is not returned to the no 0403.5.2 steam condensate systems source, indicate on-site condensate water ER 2015 Washington State Energy Code Compliance Forms for Commercial, R2 and R3 over 3 stories and all R1 - Page 5 of 7 Mechanical Permit Plans Checklist MECH-CHK' 2015 Washington State Enerav Code Comoliance Forms for Commercial Buildinas including R2 & R3 over 3 stories and all R1 Revised October 2016 ProjectTHfa: InsplrusCredit Union Expansion Date 11/15/2016 The following information is necessary to check a permit application for compliance with the mechanicial systems and equipment requirements of the Washington State Energy Code, Commerclat Provisions. D ° FOQMS 0. MM MSS AftV D (eMn- - V 21,9 Mas Opti -his Code SectionF Code Provision Information Required - Must be in permit documents Location lo Building Department (yes,no,na) Documerds Notes For buildings with food service, meat or deli departments that have 2 500,000 Btu/h of remote refrigeration capacity for coolers / freezers, indicate condenser ER and use of captured energy (service water heating, space heating, or dehumidification reheating) no C403.5.3 Energy recovery - For buildings with 2 40,000 at conditioned floor area and with 21,000,000 Btu/h of remote cooler / freezer condensers refrigeration capacity for coolers / freezers, indicate condenser ER and use of captured energy for service water heating and also for space heating, or dehumidification reheating For buildings with 24-hour operation and with > 1,500,000 Btu/h of heat rejection capacity and C403.5A Energy recovery - design service hot water bad > 250,000 Btu/h, Indicate condenser ER to pre -heat service no condenser systems water, or exception taken. Provide calculations showing the amount of recovered heat that is utilized (60% of peak heat rejection load or pre -heat service water to 65°F). Hydronic S stem Controls For hydronic system pump motors k 7.5 hp, Indicate method of variable flow control (VSD or C403.2.13 Variable flow control - equivalent method that requires 2:30% design wattage at 50% design fluid flow); note no C403.4.2.7 hydronic system pumps exception taken Identify whether hydronic coils have DDC controls and associated manner of pump speed control (differential pressure, zone h drank demand, etc For boilers that provide building heating, indicate controls that provide heating water temperature setback based on outdoor temperature For heating and chBed water systems 2 300,000 Btu/h, Indicate systems are configured to 0403.2.5 Hydronic system setback automatically reset supply water temperature based upon demand; or exception taken. no C403.4.2.4 and pan toad controls If system pump motor hp 2 3 hp, also indicate controls automatically reduce flow by 250%. For chilled water systems (2 300,000 Btu/h, pump motor hp 2 3 hp) that serve water-cooled unitary air conditioners, Indicate VSD or staged pumps in chilled water system and heat rejection loop that reduce pump flow so that one control valve Is nearly wide open, or to maintain a minimum differential pressure; or exception taken no 0403.4.2 Boiler sequencing Indicate automatic controls that sequence operation of multiple boilers no C403.4.6 Hot gas bypass limitation For cooling equipment with hot gas bypass, provide either multiple step unloading or continuous capacity modulation; indicate bypass capacity per Table C403.4.6 C403.4.2.2 Two -pipe changeover Indicate changeover deadband (min 15°F), heating / cooling mode scheduling and no systems changeover temperature range pimit 30°F 0403.4.2.6 Chiller / boiler plant pump Indicate controls are configured to automatically reduce overall plant flow and shutoff flow no isolation through individual chillers and boilers when not In use For cooling towers with fan motors t 7.5 hp, indicate VSD and method to adjust fan speed 0403.2.13.1.1 Heat rejection equipment - (adjusted based on leaving fluid temperature or condenser temperature / pressure of heat no C403A.3.1.1 variable flow control rejection device For multiple -cell heat rejection equipment with VSD, indicate controls that ramp all fans in C403.4.3.1.2 unison C403.4.3.3 Heat rejection equipment - Indicate open -crust cooling towers with multiple pumps or VSD control are designed so all cells no cooling tower flow turndown can be run in parellel 0403.4.2.3.1 Water bop heat pump - Indicate capability of central equipment to provide minimum 20°F water supply temperature no deadband deadband between heat rejection and heat addition modes; or exception taken Water loop heat pump - Indicate type of cooling tower (open- or dosed -circuit) in equipment schedule; indicate method no C403.4.2.3.2.1 heat rejection equipment used to limit system heat loss when heat rejection is not needed Zone 4 Water bop heat pump - For open- or dosed -circuit codlings towers, provide a heat exchanger that separates the no C403.4.2.3.2.1 heat rejection equipment, cooling tower and heat pump bop Zone 5 0403.4.2.3.3 Water loop heat pump - For hydronic heat pump systems with total system power> 10 hp, indicate 2 -way isolation no Isolation valves valves on each heat pump and variable flow system control Dedicated Outdoor Air Systems (DORS) - Optional through 6/30/16, Prescriptive 7/1/2016 For buildings with office, retail, education, library and fire station spaces, identify these spaces C403.6 Dedicated outdoor air on plans; indicate that ventilation air in each occupied space is provided via a DOAS system; yes C403.6.3 systems or document compliance with 0403.6.3 Impracticality, or exception taken (buildings complying with C402.4.1.4 or C406.6 may not utilize exceptions) M002 ne Energy recovery ventilation For all DOAS systems, indicate exhaust air ER method; or exception taken with supporting yes C403.6.1 with DOAS calculations. Indicate ER rated effectiveness that increases OSA enthalpy by t 50% based on delta between OSA and return air enthalpies at design conditions. M002 Indicate equipment associated with the delivery of zone level heating and cooling (fans, Heating / cooling system hydronic pumps, primary air dampers, etc) are configured to shut off, and central eqlupment is yes C403.6.2 centrals with DOAS configured to turn down, when there is no call for heating or cooling in the zone they serve M002 If applying Exception to heating / cooling fans used for air mbdng in the space during deadband periods, include fan watts per cfrn in equipment schedule M002 — 2015 Washington State Energy Code Compliance Forms for Commercial, R2 and R3 over 3 stories and all R1 - Page 6 of 7 2015 Washington State Enerov Code Compliance Forms for Commercial Buildings Including R2 & R3 over 3 stories and all R1 Revised October 2016 Project Tide: Inspirus Credit Union Expansion Date 11/15/2016 The following information is necessary to check a permit application for compliance with the mechanicial systems and equipment requirements of the Washfngton State Energy Code, Commercial Provisions. DUFF o FF FOO R"'M D@ MM Use MaT Dccem'I'Mp 31, MG P.ppboabts Code Section Code Provision Information Required - Must be in permit documents Location in Building Department (yes,no,na) Documents Notes C402A.1.4 Increased prescriptive Yes C403.6 maximum vertical Indicate that all occupied, conditioned spaces are served by a DOAS per C403.6 fenestration area with DOAS M002 Additional Efficiency Package Option, Dedicated Outside Air Systems (DOAS) C406.6 Building provided with To comply with additional efficiency package option, indicate that 90% or more of all occupied, I DOAS conditioned spaces are served by a DOAS per C403.6 Multiple Zone Air Systems Air systems serving multiple Identify supply air systems serving multiple zones and the zones they serve on plans; indicate no C403.4.4 whether system is VAV and method of primary air control; or provide supporting zones documentation for applied exception to VAV Provide equipment schedules on plans or MECH-EQ form that fist all VAV air terminals and types VAV systems serving For each air terminal include: maximum airflow rates for primary supply air during zone peak no C403.4.4 multiple zones heating and zone peak cooling; maximum airfbw during reheating, recwoling or mbdng; minimum airflow rate to maintain required ventilation, and the basis for these values; if IMC or ASHRAE 62.1 multiple zone equation is basis for minimum flow rates, provide calculation on plans C403.4A.1 Single duct VAV terminal Indicate single duct terminal units are configured to reduce primary supply air before reheating no units or recooling C403.4.4.2 Dual duct systems - terminal For systems with separate warn air and cool air ducts, indicate terminal units are configured to no units reduce the flow from one duct to minimum before mixing with air from the other duct Indicate locations of duct static pressure sensors on plans; include at least one sensor per major duct branch; verify controller setpoint pressure at each sensor is 51.2 inch w.a. For systems with zone level DDC, indicate controls are configured to monitor zone damper no C403.4.1.1 VAV system static C403.4.1.2 pure sensors - sensors and DDC set points positions and reset static pressure int based on the zone Pce P setpo requiring most pressure; include control logic that automatically detects and generates an alarm If any zone excessively drives reset logic, and allows building operators to exclude zones from reset logic Multiple -zone VAV system For systems with zone level DDC controls, indicate controls are configured to automatically no C403.4.4.3 ventilation optimization reduce outdoor airflow, in response to changes in system ventilation efficiency, or exception controls ltaken no C403.4.4.4 VAV system supply air reset Indicate controls automatically reset supply air temperature in response to building loads or outdoor air temperature; or exception taken Multiple Zone HVAC Systems, High Peformance VAV - Required for systems utilizing C403.6 DOAS Exception 2, must comply with all 16 provisions no 0403.7, Air economizer Indicate system is configured for 100% air economizer operation and complies with all related Item 1 economizer requirements per C403.3 (without economizer exceptions no C403.7, Direct digital controls (DDC) Provide DDC controls for all components of system; identify all DDC system input / output Item 2 control points; indicate capability for trending and graphical display For systems with minimum OSA > 2,500 cfm, indicate outdoor airflow monitoring station that C403.7, Outdoor airflow measures OSA intake under all load conditions; indicate control sequence to reduce system na Item 3 measurement and reduction OSA cfm based on VAV terminal feedback of ventilation efficiency (per C403.4.4.3 without exceptions) or DCV (per 0403.2.6.2) no C403.71 Supply airflow measurement For systems with minimum OSA > 2,500 corn, indicate suppy airflow monitoring station capable Item 4 of measuring supply air delivered to VAV terminals under all bad conditions C403.7, Zone isolation and Verify maximum area served by a single HPVAV system is:5 50,000 at, or one entire floor, no Item 5 maximum area served whichever is greater, In addition if a system serves > 25,000 at, that Includes areas that are expected to be occupied non -simultaneously, indicate zone isolation controls per C403.2.4.4 no 0403.7, Interior / exterior zone design supply air Verify that VAV terminals serving interior cooling driven loads are sized per design supply air nem 6 temperature temperature that is 5`F higher than VAV terminals serving exterior zones C403.7, Maximum air terminal inlet Identify air terminals with minimum primary airflow setpoints > 50% of maximum setpoint in no Item 7 velocity equipment schedule or MECH-EQ form; indicate air terminal inlet velocity does not exceed 900 fpm no C403.7. Sequence of operation Indicate DDC system sequences of operation are designed and configured per ASHRAE GPC Item 8 36 C403.7, Maximum allowable system Verify fan system bhp is 5 90% of the bhp limn per Option 2 equation in Table C403.2.11.1(1), no Item 9 brake horsepower provide MECH-FANSYS form for each system Indicate all series and parallel terminal fans have electronically commutated motors; indicate C403.7, Fan -powered terminal unit DDC control system is configured to vary air terminal fan speed as a function of the bad; no Item 10 motor and control indicate fan speed during periods of low heating, low cooling, or ventilation only is 5 66% of 1 peak design air flow or provide supporting documentation for applied exception • 2015 Washington State Energy Code Compliance Forms for Commercial, R2 and R3 over 3 stories and all R1 - Page 7 of 7 2015 Washinaton State Enerov Code ComDliance Forms for Commercial Buildings includina R2 & R3 over 3 stories and all R1 Revised October 2016 Project Title: Inspirus Credit Union Expansion Date 11/15/2016 The following information Is necessary to check a permit application for compliance with the mechanloial systems and equipment requirements of the Washington State Energy Code, Commercial Provisions. DPAFT FT FOR M S Da MW Use Aftev Dwamb T 310 WaS A 0-11ts Code Section Code Provision Information Required - Must be in permit documents Location in Building Department (yes,no,na) Documents Notes 0403.7, Application of single duct Indicate VAV terminal types on plans; verify fan powered terminal units only serve perimeter no Item 11 fan-poweredand terminal zones with envelope bads; verify all other zones are served by single duct terminal units units C403.7, Fan -powered terminal unit Indicate DDC controls are configured to automatically reset the primary supply air cfm setpoint no Item 12 primary air reset of all fan -powered terminal units to the minimum required to maintain ventilation during occupied heating or deadband, based upon the VAV air handling unit OSA ventilation fraction For spaces > 150 of with occupant density 2 25 people / 1000 at, indicate space Is served by a C403.7, High occupancy space dedicated terminal unit with DCV control that resets terminal unit ventilation setpoints also no Item 13 controls indicate occupancy sensor control that automatically reduces minimum ventilation to zero and sets back room heating and cooling setpoints by;! 5°F For server, electronic equipment, telecom or similar spaces with cooling loads > 5 W/sf, no 0403.7, Dedicated HVAC systems indicate spaces are served by independent HVAC systems that are separate from HPVAV Item 14 systems serving rest of building; indicate dedicated HVAC systems have air economizer controls or energy recovery per C403.3 Exception 9 Indicate whether systems are served by a high efficiency heating water plant, or a high efficiency chffled water plant If complying via high efficiency heating water plant: Indicate all VAV terminals have hydronic heating coils served by heating water system with either gas-fired boiler(s) with thermal 0403.7, efficiency i 90%, air -to -water heat pumps, or heat recoverychillers no kern 15 Central plant efficiency H complying via high efficiency chilled water plant Indicate all VAV air handlers have cooling coils served by chfflem with rated IPLV efficiency that exceeds WSEC fisted IPLV by at least 25% per Table C403.2.3(7) (note water-cooled IPLV is max, all others are min); indicate smallest chiller or compressor in plant is 5 20% of total plant capacity, or provide thermal storage sized for5 20% of total plant capacity C403.7, Fault detection and Indicate DDC system includes a fault detection and diagnostics (FDD) system configured to no Item 16 diagnostics monitor operation and provide fault reporting of required parameters for all VAV arc handlers and VAV air terminal units in the HPVAV system HVAC Equipment Energy Use Metering HVAC equipment energy For new buildings > 50,000 at and building additions > 25,000 at, verily energy use metering of no C409.3.1 all equipment used to provide space heating and cooling, dehumidification and ventilation will use metering be rovided r 0409; indicate equipment eligible for exception Project Close Out Documentation Documentation and project Indicate in plans that project close out documentation and training of building operations yes C103.6 close out submittal personnel is required for all mechanical components, equipment and systems governed by requirements this code, indicate close out documentation shall include: record documents, O&M manuals, applicable WSEC compliance fortes and calculations Documentation and System Speciflc Requirement To Support Commissioning Indicate in plans and specifications that commissioning per C408 Is required for all applicable systems; M001 Provide general summary of required documentation including: functional performance testing 0403.2.10 Commissioning yes C408 1 1 requirements in construction results, commissioning progress report (preliminary) and final report, and all project dose out documents documentation required perC103.6 M001 Include in general summary that a Commissioning Compliance Checklist (Figure C408.1.2.1) shall be provided to the jurisdiction upon completion of commissioning progress report M001 For buildings with 2 240,000 Btu/h total output cooling capacity or 2 300.,000 Btu/h total output heating capacity, indicate that all mechanical systems regardless of individual capacity are C408.2 Scope of mechanical. required to be commissioned; or provide building heating / cooling capacity calculation Yes systems commissioning demonstrating eligibiity for exception M002 Identify all equipment and controls that the WSEC defines as being capable of and / or configured to perform specific functions M002 Air system and hydronic Indicate in plans that air and fluid flow rates shall be tested and balanced within the tolerances no 0408.2.2 system balancing defined in the specifications; indicate systems shall be balanced in a manner to first minimize throttling losses, then adjusted to meet design flow conditions C408,2,2.1 Air system balancing Indicate devices that provide the capability to balance all supply air outlets, zone terminals and yes devices air handling equipment requiring system balancing M201 C408.2.2.2 Hydronic system balancing Indicate devices that provide the capability to isolate, balance and measure flow across all no devices hydronic equipment requiring system balancing including heating and cooling coils and pumps L". C408.2.3 Functional performance Identify in plans and specifications the intended operation of all equipment and controls during testing criteria all modes of operation, including interfacing between new and existing -to -remain systems M001 City of Tukwila Department of Community Development - Jack Pace, Director February 16, 2018 Jason Whitney Pinchiff Mechanical LLC 605 S Lucile St Seattle, WA 98108 RE: Request for Extension #1 Permit Number M16-0176 Dear Mr. Whitney, Allan Ekberg, Mayor This letter is in response to your written request for an extension to Permit MI6 -0176. The Building Official, Jerry Hight, has reviewed your letter and considered your request to extend the above referenced permit. It has been determined that the City of Tukwila Building Division will be granting an extension to the permit through August 28, 2018. If you should have any questions, please contact our office at (206) 431-3670. Sincerely, Rachelle Ripley Permit Technician File: Permit No. MI6 -0176 Tukwila City Hall • 6200 Southcenter Boulevard • Tukwila, WA 98188 • 206-433-1800 • Website: TukwilaWA.gov Pinqhiff ff MECHANICAL Design • Installation • service Reference: Permit No. M16-0176 To whom it may concern, RECEIVED CITY OF TUKWILP FEB 15 2018 PERMIT CENTER Due to the phasing and size of the job associated with Permit No. M16-0176 the schedule is going to exceed the 180 -day window the permit was initially scheduled for. Please extend the permit by another 180 days. Respectfully, Jason Whitney Project Manager Pinchiff Mechanical 206-379-2435 Jasonw@pinchiffinechanical.com Request for Extension xtensi n#, o Current Expiration Date: Extension Request: � Approved for { �/J d days ❑ Denied (provide explanation) I Signature/Initials 1/2/2018 City of Tukwila Allan Ekberg, Mayor Department of Community Development Jack Pace, Director MATT LAASE 311 FIRST AVE S SEATTLE, WA 98104 RE: Permit No. M16-0176 INSPIRUS CREDIT UNION 5200 SOUTHCENTER BLVD Dear Permit Holder: In reviewing our current records, the above noted permit has not received a final inspection by the City of Tukwila Building Division. Per the International Building Code, International Mechanical Code, Uniform Plumbing Code and/or the National Electric Code, every permit issued by the Building Division under the provisions of these codes shall expire by limitation and become null and void if the building or work authorized by such permit has not begun within 180 days from the issuance date of such permit, or if the building or work authorized by such permit is suspended or abandoned at any time after the work has begun for a period of 180 days. Your permit will expire on 2/28/2018. Based on the above, you are hereby advised to: 1) Call the City of Tukwila Inspection Request Line at 206-438-9350 to schedule for the next or final inspection. Each inspection creates a new 180 day period, provided the inspection shows progress. -or- 2) Submit a written request for permit extension to the Permit Center at least seven(7) days before it is due to expire. Address your extension request to the Building Official and state your reason(s) for the need to extend your permit. The Building Code does allow the Building Official to approve one extension of up to 180 days. If it is determined that your extension request is granted, you will be notified by mail. In the event you do not call for an inspection and/or receive an extension prior to 2/28/2018, your permit will become null and void and any further work on the project will require a new permit and associated fees. Thank you for your cooperation in this matter. Sincerely, Bill Rambo Permit Technician File No: M16-0176 6300 Southcenter Boulevard Suite #100 • Tukwila, Washington 98188 • Phone 206-431-3670 • Fax 206-431-3665 MEMORANDUM TO: Laurie Anderson FROM: Brenda Holt WK DATE: September 6, 2017 SUBJECT: Refund for Electrical Permit M16-0176 Please draw a check in the amount of $660.45 (six hundred sixty dollars and forty-five cents) to be payable to Inspirus Credit Union at 5200 Southcenter Blvd in Tukwila, WA 98188. The value for this permit was decreased. Please provide the refund as follows: Account Amount 000.322.102.00.00 $660.45 Total $660.45 Please forward the check to me and I will forward it on to the applicant. Thank you! Pi nchiffff MECHANICAL Design • Installation • Service To whom it may concern, There was an error in the initial valuation ($850,000) of the Inspirus Credit Union project's mechanical permit. The initial valuation included plumbing work and controls work that should not be part of the mechanical permit. That said, the actual valuation for permit# M16-0176 should be $493,800. Sorry for any confusion, Jason Whitney Project Manager Pinchiff Mechanical iasonw@pinchiffinechanical.com 206-379-2435 Value Base Fee Mulitiplier above $250,000 Permit Fee Plan Check Fee $850,000 $ 2,319.20 $ 4,440.00 $ 6,791.70 $ 1,697.93 $493,800 $ 2,319.20 $ 1,798.20 $ 4,149.90 $ 1,037.48 Refund Amount $ 660.45 Cety of Tukwila Department of Community Development - Jack Pace, Director May 17, 2017 Matt Laase Jackson/Main Architecture 311 First Ave S Seattle, WA 98104 RE: Request for Application Extension #1 Permit Number M16-0176 Dear Mr. Laase, Allan Ekberg, Mayor This letter is in response to your written request for an extension to Application Number M 16-0176. The Building Official, Jerry Hight, has reviewed your letter and considered your request to extend the above referenced permit. It has been determined that the City of Tukwila Building Division will be granting an extension to the permit through November 21, 2017. If you should have any questions, please contact our office at (206) 431-3670. Sincerely, � 11WE WIA Bill Rambo Permit Technician File: Permit No. M16-0176 Tukwila City Hall • 6200 Southcenter Boulevard • Tukwila, WA 98188 • 206-433-1800 • Website: TukwilaWA.gov Bill Rambo From: Matt Laase <Matt.Laase@jacksonmain.com> Sent: Friday, May 12, 2017 9:01 AM To: Bill Rambo Cc: Lindsay Brown; Carol Cameron (Carol@inspiruscu.org) Subject: Inspirus Permit Applications Extension Request Dear Bill, We respectfully request an extension on picking up the permits listed below as we are awaiting final reviews and corrections on our building permit application (D16-0317) and the client is in the process of contracting with a general contractor who will be picking up the permits. The permits in need of a 90 day extension are: PG16-0169 EL16-1064 M16-0176 Please let me know if you need any additional information. All 3 permits listed above are due to expire on 5/21/2017. Thanks, Matt Matthew Laase AIA tt Principal �Q JACKSON I MAIN Architecture, P.S. 311 First Avenue South Seattle, Washington 98104 206.324.4800 P 1206.465.4452 M www.iacksonmain.com Request for Extension. # I Current Expiration Date: ^�' _ 17 Extension Request: Approved for days ❑ Denied (provide explanation) Signature/initials RECEIVED CITY OF TUKWILA MAY 12 2011 1 PERMIT CENTER 4/3/2017 City of Tukwila Allan Ekberg, Mayor Department of Community Development Jack Pace, Director MATT LAASE 311 FIRST AVE S SEATTLE, WA 98104 RE: Permit Application No. M 16-0176 INSPIRUS CREDIT UNION 5200 SOUTHCENTER BLVD Dear MATT LAASE, In reviewing our current application files, it appears that your permit applied for on 11/21/2016, has not been issued by the City of Tukwila Permit Center. Per the International Building Code, International Mechanical Code, Uniform Plumbing Code and/or National Electrical Code every permit application not issued within 180 days from the date of application shall expire and become null and void. Currently your application has a status of APPROVED and is due to expire on 5/21/2017. If you still plan to pursue your project, you are hereby advised.to do one of the following: 1) If the plan review is complete for the project and your application is approved, you may pick up the application before the date of expiration. At the time of permit issuance the expiration date will automatically be extended 180 days. -or- 2) If the plan review is not completed submit a written request for application extension (7) seven days in advance of the expiration date. Address your extension request to the Building Official and state your reason(s) for the need to extend your application. The Building Code does allow the Building Official to approve one extension of up to 90 days. If it is determined that your extension request is granted, you will be notified by mail. In the event that we do not receive your written request for extension or request is denied, your permit application will expire and your project will require a new permit application, plans and specifications, and associated fees. Thank you for your cooperation in this matter. Sincerely, Rachelle Ripley Permit Technician File No: M 16-0176 6300 Southcenter Boulevard Suite #100 • Tukwila Washington 98188 • Phone 206-431-3670 • Fax 206-431-3665 PERMIT COORD COP'S" PLAN REVIEW/ROUTING SLIP PERMIT NUMBER: M16-0176 DATE: 11/21/16 PROJECT NAME: INSPIRUS CREDIT UNION SITE ADDRESS: 5200 SOUTHCENTER BLVD X Original Plan Submittal Revision # before Permit Issued Response to Correction Letter # DEPARTMENTS: AW0 1 Building Division Revision # after Permit Issued " P)A- I P Fire Prevention Planning Division ❑ Public Works ❑ Structural ❑ Permit Coordinator PRELIMINARY REVIEW: DATE: 11/22/16 Not Applicable ❑ (no approval/review required) REVIEWER'S INITIALS: Structural Review Required ❑ DATE: APPROVALS OR CORRECTIONS: DUE DATE: 12/20/16 Approved ❑ Approved with Conditions �r Corrections Required ❑ (corrections entfred in Reviews) Notation: REVIEWER'S INITIALS: Denied ❑ (ie: Zoning Issues) DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: 12/18/2013 PINCHIFF MECHANICAL LLC Home 131pahol Contact Safety & Health Claims & Insurance Washington State Department of k, Labor & industries PINCHIFF MECHANICAL LLC Owner or tradesperson 650 S Lucile St. 603 322 609 SEATTLE, WA 98108 Principals 206-643-2046 PINCHIFF, KENNETH KING County ANDREW, PARTNER/MEMBER PINCHIFF EQUINOX BUSNSS LAW GROUP KENNETH PINCHIFF; PLLC. AGENT Doing business as PINCHIFF MECHANICAL LLC Page 1 of 2 Search L&I I [ A-Z.Index help My L&I Workplace Rights Trades & Licensing WA UBI No. Business type 603 322 609 Limited Liability Company Governing persons KENNETH PINCHIFF KENNETH PINCHIFF; License Verify the contractor's active registration / license / certification (depending on trade) and any past violations. Construction Contractor Active. Meets current requirements. License specialties Heating/Vent/Air-Conditioning and Refrig (HVAC/R) License no. PINCHML876PG Effective — expiration 10/07/2013-10/07/2017 Bond ............... Great American Ins Co $6,000.00 Bond account no. 2208838 Received by L&I Effective date 10/07/2013 11/01/2013 Expiration date Until Canceled Insurance ...._..._.................. Liberty Northwest Ins Corp $1,000,000.00 Policy no. BKS55785886 Received by L&I Effective date 08/29/2016 10/04/2013 Expiration date 10/04/2017 Help us improve https://secure.Ini.wa.gov/verify/Detail.aspx?UBI=603322609&LIC=PINCHML876PG&SAW= 9/1/2017 ►0 :1 ABBREVIATIONS: 0 DIAMETER, PHASE A AIR AAV AUTOMATIC AIR VENT ABV ABOVE AC AIR CONDITIONING UNIT AD AREA DRAIN, ACCESS DOOR ADA AMERICANS WITH DISABILITIES ACT AFF ABOVE FINISHED FLOOR AHJ AUTHORITY HAVING JURISDICTION AHU AIR HANDLING UNIT ALT ALTERNATE ALUM ALUMINUM AMB AMBIENT APD AIR PRESSURE DROP APPROX APPROXIMATE ARCH ARCHITECT ASHRAE AMERICAN SOCIETY OF HEATING, REFRIGERATION AND AIR-CONDITIONING ENGINEERS, INC. ATM ATMOSPHERE B BOILER BDD BACKDRAFT DAMPER BF BELOW FLOOR BFF BELOW FINISHED FLOOR BHP BRAKE HORSEPOWER BLDG BUILDING BLW BELOW BOD BOTTOM OF DUCT BOP BOTTOM OF PIPE BOT BOTTOM BTU BRITISH THERMAL UNIT BTUH BRITISH THERMAL UNIT PER HOUR C CONDENSATE PIPING CAP CAPACITY CBV CIRCUIT BALANCING VALVE CC COOLING COIL CD CEILING DIFFUSER CFH CUBIC FEET PER HOUR CFM CUBIC FEET PER MINUTE CH CHILLER, CABINET HEATER CHWP CHILLED WATER PUMP CHWR CHILLED WATER RETURN CHWS CHILLED WATER SUPPLY CHWS/R CHILLED WATER SUPPLY AND RETURN CI CAST IRON CL CENTER LINE CLG CEILING CMU CONCRETE MASONRY UNIT CO CLEANOUT COMB COMBUSTION, COMBINATION COND CONDENSATE CONN CONNECTION CONT CONTINUE, CONTROL CONTR CONTRACTOR COP COEFFICIENT OF PERFORMANCE CP CONDENSATE PUMP CT COOLING TOWER CU CONDENSING UNIT, CUBIC CV CHECK VALVE, CONSTANT VOLUME CW DOMESTIC COLD WATER CWP CONDENSER WATER PUMP CWR CONDENSER WATER RETURN CWS CONDENSER WATER SUPPLY CWS/R CONDENSER WATER SUPPLY AND RETURN DB DRY BULB DC DUCT COIL DDCV DOUBLE DETECTOR CHECK VALVE DEPT DEPARTMENT DEG DEGREE DF DRINKING FOUNTAIN DFU DRAINAGE FIXTURE UNIT DH DUCT HEATER DI DUCTILE IRON DIA DIAMETER DIAG DIAGRAM DIFF DIFFERENTIAL DIM DIMENSION DN DOWN DX DIRECT EXPANSION DWG DRAWING DWP DOMESTIC WATER PUMP (E) EXISTING EA EACH, EXHAUST AIR EAT ENTERING AIR TEMPERATURE ECG EGGCRATE GRILLE EDH ELECTRIC DUCT HEATER EER ENERGY EFFICIENCY RATIO EF EXHAUST FAN EFF EFFICIENCY EG EXHAUST GRILLE EJ EXPANSION JOINT ELEC ELECTRIC ELEV ELEVATION EMCS ENERGY MANAGEMENT CONTROL SYSTEM ENT ENTERING EQUIP EQUIPMENT ESP EXTERNAL STATIC PRESSURE ET EXPANSION TANK ETC AND SO FORTH EUH ELECTRIC UNIT HEATER EVAP EVAPORATOR, EVAPORATIVE EWC ELECTRIC WATER COOLER EWH ELECTRIC WATER HEATER EWT ENTERING WATER TEMPERATURE EX EXHAUST EXT EXTERIOR, EXTERNAL -F DEGREES FAHRENHEIT FC FLEXIBLE CONNECTION FCO FLOOR CLEANOUT FCU FAN COIL UNIT FD FLOOR DRAIN F/D FIRE DAMPER FFD FUNNEL FLOOR DRAIN FLA FULL LOAD AMPS FLR FLOOR. FLEX FLEXIBLE FP FIRE PROTECTION, FIRE PUMP FPM FEET PER MINUTE FPS FEET PER SECOND FS FLOOR SINK FIS COMBINATION FIRE SMOKE DAMPER FT FEET FTU FAN POWERED TERMINAL UNIT FTR FINNED TUBE RADIATION GAL GALLON GALV GALVANIZED GC GENERAL CONTRACTOR GPD GALLONS PER DAY GPH GALLONS PER HOUR GPM GALLONS PER MINUTE GR GRILLE GRD GRILLES, REGISTERS, AND DIFFUSERS GWB GYPSUM WALLBOARD HC HEATING COIL HD HEAD HOR HORIZONTAL HP HEAT PUMP, HORSEPOWER HR HOUR HRU HEAT RECOVERY UNIT HT HEIGHT HTR HEATER HX HEAT EXCHANGER HVAC HEATING, VENTILATION & AIR CONDITIONING HW DOMESTIC HOT WATER HWC DOMESTIC HOT WATER CIRCULATING HWS HEATING WATER SUPPLY HWR HEATING WATER RETURN HZ HERTZ IAQ !NDOOR AIR QUALITY I.E. INVERT ELEVATION IN INCH INCL INCLUDING INT INTERNAL INV INVERT ISP INTERNAL STATIC PRESSURE L LENGTH LAT LEAVING AIR TEMPERATURE LAV LAVATORY LB POUND LBS/HR POUNDS PER HOUR LD LINEAR DIFFUSER LF LINEAR FEET LL REFRIGERANT LIQUID LINE LRA LOCKED ROTOR AMPS LVG LEAVING LVR LOUVER LWT LEAVING WATER TEMPERATURE PVC POLYVINYL CHLORIDE MAT MIXED AIR TEMPERATURE MAV MANUAL AIR VENT MAX MAXIMUM MBF: THiJUSANDS OF BTUH MCA MINIMUM CIRCUIT AMPACITY MECH MECHANICAL MED MEDIUM MER', tIIMUM,EFFICIENCY REPORTING VALUE MFR MANUFACTURER RAIN MINIMUM MISC MISCELLANEOUS MOCP MAXIMUM OVERCURRENT PROTECTION MS MOP SINK MTD MOUNTED MU MAKEUP WATER MUA MAKE-UP AIR UNIT (N) NEW NA NOT.- NC NOISE CRITERIA, NORMALLY CLOSED NEG NEGATIVE NO NORMALLY OPEN NO. NUMBER NOM NOMINAL NTS NOT TO SCALE OA OUTSIDE AIR OAT OUTSIDE AIR TEMPERATURE OBD OPPOSED BLADE DAMPER OC ON CENTER OCC OCCUPIED OSA OUTSIDE AIR. OT OFF TOP OV OUTLET VELOCITY P PRESSURE,PUMP PD PRESSURE DROP PERF PERFORATED PH PHASE POC POINT OF CONNECTION PRESS PRESSURE PRV PRESSURE REDUCING VALVE PSI POUNDS PER SQUARE INCH PSIG POUNDS PER SQUARE INCH GAUGE PSIA POUNDS PER SQUARE INCH ABSOLUTE PTRV PRESSURE/TEMPERATURE RELIEF VALVE PU PUMP PVC POLYVINYL CHLORIDE R REFRIGERANT PIPING RA RETURN AIR RAF RETURN/RELIEF AIR FAN RAG RETURN AIR GRILLE RCP REFLECTED CEILING PLAN RD ROOF DRAIN REF REFERENCE, RETURN/EXHAUST FAN REG REGISTER REL RELIEF REQD REQUIRED RET RETURN RF RETURN FAN RG RETURN GRILLE RH RELATIVE HUMIDITY, ROOF HOOD RHC REHEAT COIL RI&C ROUGH IN AND CONNECT RLA RATED LOAD AMPS RM ROOM ROD ROOF OVERFLOW DRAIN RPBA REDUCED PRESSURE BACKFLOW ASSEMBLY RPBP REDUCED PRESSURE BACKFLOW PREVENTER RPM REVOLUTIONS PER MINUTE RTU ROOFTOP UNIT RV RELIEF VALVE SA SUPPLY AIR SAD SUPPLY AIR DIFFUSER SAT SUPPLY AIR TEMPERATURE SCFM STANDARD CUBIC FEET PER MINUTE SCH SCHEDULE SCHEM SCHEMATIC SID SMOKE DAMPER SF SUPPLY FAN, SQUARE FOOT SG SUPPLY GRILLE SL REFRIGERANT SUCTION LINE, SOUND LINING DP SHEET METAL AND AIR CONDITIONING SMACNA CONTRACTORS' NATIONAL ASSOCIATION, INC. SP STATIC PRESSURE SPEC SPECIFICATION SQ SQUARE SRV SAFETY RELIEF VALVE SS STAINLESS STEEL ST STORAGE TANK, SOUND TRAP STD STANDARD STIR STARTER,STRUCTURAL SUCT SUCTION TAB TESTING, ADJUSTING AND BALANCING TDH TOTAL DYNAMIC HEAD TEMP TEMPERATURE TG TRANSFER GRILLE TOD TOP OF DUCT TOF TOP OF FOOTING TOP TOP OF PIPE TP TOTALPRESSURE TPRV TEMPERATURE/PRESSURE RELIEF VALVE TSP TOTAL STATIC PRESSURE TSTAT THERMOSTAT TU TERMINAL UNIT TYP TYPICAL UH UNIT HEATER UNOCC UNOCCUPIED URN URINAL V VENT, VOLTS VAC VACUUM VAV VARIABLE AIR VOLUME UNIT VB VACUUM BREAKER VD VOLUME DAMPER VEL VELOCITY VENT VENTILATION, VENTILATOR VFD VARIABLE FREQUENCY DRIVE VTR VENT THRU ROOF W WASTE, WATT, WIDTH W/ WITH WB WET BULB WC WATER CLOSET WCO WALL CLEANOUT WH WATER HEATER WM WATER METER W/O WITHOUT WPD WATER PRESSURE DROP WSFU WATER SUPPLY FIXTURE UNIT WT WEIGHT WTD WATER TEMPERATURE DROP REFERENCE SYMBOLS NEW MECHANICAL WORK EXISTING MECHANICAL WORK EXISTING MECHANICAL WORK TO BE DEMOLISHED -------- ENLARGED PLAN BORDER MATCHLINE 1 MX.X SECTION IDENTIFIER 1 DETAIL OR DRAWING IDENTIFIER MX.X REVISION CLOUD INDICATES WHERE SECTION APPEARS INDICATES REVISION & NUMBER FLAG NOTE AHU-XXX EQUIPMENT IDENTIFIER POINT OF CONNECTION NORTH ARROW MECHANICAL ACCESS PLUMBING LINE DESIGNATION SYMBOLS DOMESTIC COLD WATER (POTABLE) -- - DOMESTIC HOT WATER (POTABLE) DOMESTIC HOT WATER CIRCULATING - (POTABLE) SANITARY SEWER ABOVEGROUND ® SANITARY SEWER UNDERGROUND - - - - - - - VENT PIPING PIPING ELEMENTSNALVING NO charlcq¢s shalt be rrfad$ to fha SCOM C3� e•OrI( "'IffIc'ut Prior approval of U'ding Division. �fOT" will require a netiv pian submittal End may include additional plan review fees. DUCTWORK SYMBOLS VALVE FCO CLEAN-OUT (FLOOR) --OWCO CLEAN-OUT (WALL) --11CO CLEAN-OUT CO PIPE CONTINUES INTERNALLY LINED DUCT -� PIPE CAP MANUAL VOLUME DAMPER 00 PIPE RISING UP SIDEWALL GRILLE (RETURN OR EXHAUST), PIPE DROPPING DOWN BACKDRAFT DAMPER PIPE CONNECTION DP PIPE CONNECTION DOWN --- o� FLOOR DRAIN $ FLOOR SINK OVTR VENT THRU ROOF SECOND FLOOR FIRE SPRINKLER PLAN TRENCH DRAIN NO charlcq¢s shalt be rrfad$ to fha SCOM C3� e•OrI( "'IffIc'ut Prior approval of U'ding Division. �fOT" will require a netiv pian submittal End may include additional plan review fees. DUCTWORK SYMBOLS RLECOPY Permit Moa 0 t7 Plan i eviDvd t prowl is subject to errors and omissions. 470vai of cOnsirUciiOn docmi encs does riot alo0ho ize to violation of any adopted code or ordinance. Rec !Dt of approved F Dj: Hata: %OILY vI I UI%Wlld BUILDING DIVISION JSE x,':!!91 F'�!RMIT Rt CIURt`:: D FOP, 0 M-achanicalr Stec 1Cai W -P mbing 3S POM Ci=y of Tukwila DIFFUSER, REGISTER, AND GRILLE SYMBOLS 0M NEW DUCTWORK ® SUPPLY DIFFUSER RISE OR DROP DIRECTION RETURN OR RELIEF GRILLE ® OF AIR FLOW CO SIDEWALL GRILLE (SUPPLY), INTERNALLY LINED DUCT -� LOUVER (EXHAUST OR RETURN) MANUAL VOLUME DAMPER VF BDD SIDEWALL GRILLE (RETURN OR EXHAUST), STARTER OR STARTER/DISCONNECT BACKDRAFT DAMPER LOUVER (OUTSIDE) DP MOTOR OPERATED DAMPER OROUND DIFFUSER $ DUCT SMOKE DETECTOR FIRST FLOOR FIRE SPRINKLER PLAN M7.02 SECOND FLOOR FIRE SPRINKLER PLAN FIRE DAMPER 6. PROVIDE LINE SIZE STRAINER UPSTREAM OF EACH BACKFLOW 0o PREVENTER, WATER PRESSURE REDUCING VALVE, AUTOMATIC SMOKE DAMPER FLOW CONTROL VALVE, CONTROL VALVE, SOLENOID VALVE, DUCTS, PIPES, CONDUITS, SUSPENDED EQUIPMENT, ETC., IN GAS PRESSURE REGULATOR, AND PUMP. PROVIDE SHUTOFF COMBINATION FIRE/SMOKE DAMPER VALVE ON EACH SIDE OF STRAINER. 5. COORDINF I E EQUIPMENT CONNECTIONS WITH AJM HORIZONTAL FIRE DAMPER Orm HORIZONTAL SMOKE DAMPER OTHERWISE. HORIZONTAL COMBINATION FIRE/SMOKE DAMPER HVAC/SHEET METAL: FLEXIBLE CONNECTION 1. DUCTWORK DIMENSIONS, AS SHOWN ON THE DRAWINGS, ARE UC UNDERCUT DOOR ® ® SUPPLY AIR DUCT SECTION ® RETURN OR OUTSIDE AIR DUCT SECTION ® ® EXHAUST AIR DUCT SECTION TANKS, WATER HEATERS, AND STORAGE TANKS. COMPLY RECTANGULAR DUCT UP WITH REQUIREMENTS FOR EQUIPMENT BASES AND 3. PROVIDE MANUAL VOLUME DAMPER FOR EACH DIFFUSER, FOUNDATIONS' SPECIFIED IN DIVISION 03. RECTANGULAR DUCT DOWN 7. PROVIDE MISCELLANEOUS STEEL REQUIRED TO ENSURE 4. PROVIDE DUCT ACCESS DOORS AT DUCT SMOKE DETECTORS, PROPER INSTALLATION OF MECHANICAL SYSTEMS. ROUND DUCT UP 8. LOCATE VALVES, WATER HAMMER ARRESTERS, CLEANOUTS, DAMPERS, SMOKE DAMPERS, COMBINATION FIRE/SMOKE DAMPERS, CONTROLS AND SIMILAR COMPONENTS SO THAT ROUND DUCT DOWN THEY ARE ACCESSIBLE. PROVIDE ACCESS DOORS FOR AND LOUVER PLENUMS. MECHANICAL EQUIPMENT INSTALLED BEHIND WALLS, ABOVE FLEXIBLE DUCTWORK RLECOPY Permit Moa 0 t7 Plan i eviDvd t prowl is subject to errors and omissions. 470vai of cOnsirUciiOn docmi encs does riot alo0ho ize to violation of any adopted code or ordinance. Rec !Dt of approved F Dj: Hata: %OILY vI I UI%Wlld BUILDING DIVISION JSE x,':!!91 F'�!RMIT Rt CIURt`:: D FOP, 0 M-achanicalr Stec 1Cai W -P mbing 3S POM Ci=y of Tukwila DIFFUSER, REGISTER, AND GRILLE SYMBOLS 0M AIR DEVICE TAG ® SUPPLY DIFFUSER ® RETURN OR RELIEF GRILLE ® EXHAUST GRILLE CO SIDEWALL GRILLE (SUPPLY), G -� LOUVER (EXHAUST OR RETURN) OCCUPANCY SENSOR VF VARIABLE FREQUENCY DRIVE. SIDEWALL GRILLE (RETURN OR EXHAUST), STARTER OR STARTER/DISCONNECT ff"d LOUVER (OUTSIDE) DP LINEAR GRILLE OROUND DIFFUSER 0 REVIEWED FOR CODE COMPLIANCE APPROVED DEC 0 6 2616 K City of Tukwila BUILDING DIVISION GENERAL NOTES: COMMISSIONING: COMMISSIONING SHALL BE PROVIDED PER C408 AND IS REQUIRED FOR ALL MECHANICAL SYSTEMS REGARDLESS OF CAPACITIES; PROVIDE FUNCTION PERFORMANCE TESTING RESULTS, COMMISSIONING PROGRESS REPORT (IFRELIMINARY) AND FINAL REPORT, AND ALL PROJECT CLOSE OUT DOCUMENTATION REQUIRED PER C103.6. A COMMISSIONING COMPLIANCE CHECKLIST SHALL BE PROVIDED TO THE JURISDICTION UPON COMPLETION OF COMMISSIONING PROGRESS REPORT. PROJECT CLOSEOUT DOCUMENTATION: PROJECT CLOSE OUT DOCUMENTATION AND TRAINING OF BUILDING OPERATIONS PERSONNEL IS REQUIRED FOR ALL MECHANICAL COMPONENTS, EQUIPMENT AND SYSTEMS GOVERNED BY THIS CODE. CLOSE CUT DOCUMENTATION SHALL INCLUDE: RECORD DOCUMENTS, O&M MANUALS, APPLICABLE WSEC COMPLIANCE FORMS AND CALCULATIONS. MECHANICAL SHEET LIST ROOM THERMOSTAT O ROOM SENSOR ® ROOM PRESSURE SENSOR ® ROOM HUMIDITY SENSOR CO ROOM CARBON MONOXIDE SENSOR G ROOM CARBON DIOXIDE SENSOR OS OCCUPANCY SENSOR VF VARIABLE FREQUENCY DRIVE. STR STARTER OR STARTER/DISCONNECT ff"d DIRECT DIGITAL CONTROL PANEL DP DIFFERENTIAL PRESSURE TRANSMITTER - - - - - - - - - -- CONTROL WIRING $ SWITCH FIRST FLOOR FIRE SPRINKLER PLAN M7.02 REVIEWED FOR CODE COMPLIANCE APPROVED DEC 0 6 2616 K City of Tukwila BUILDING DIVISION GENERAL NOTES: COMMISSIONING: COMMISSIONING SHALL BE PROVIDED PER C408 AND IS REQUIRED FOR ALL MECHANICAL SYSTEMS REGARDLESS OF CAPACITIES; PROVIDE FUNCTION PERFORMANCE TESTING RESULTS, COMMISSIONING PROGRESS REPORT (IFRELIMINARY) AND FINAL REPORT, AND ALL PROJECT CLOSE OUT DOCUMENTATION REQUIRED PER C103.6. A COMMISSIONING COMPLIANCE CHECKLIST SHALL BE PROVIDED TO THE JURISDICTION UPON COMPLETION OF COMMISSIONING PROGRESS REPORT. PROJECT CLOSEOUT DOCUMENTATION: PROJECT CLOSE OUT DOCUMENTATION AND TRAINING OF BUILDING OPERATIONS PERSONNEL IS REQUIRED FOR ALL MECHANICAL COMPONENTS, EQUIPMENT AND SYSTEMS GOVERNED BY THIS CODE. CLOSE CUT DOCUMENTATION SHALL INCLUDE: RECORD DOCUMENTS, O&M MANUALS, APPLICABLE WSEC COMPLIANCE FORMS AND CALCULATIONS. MECHANICAL SHEET LIST M0.01 MECHANICAL LEGEND AND GENERAL NOTES M0.02 MECHANICAL SCHEDULES M0.03 MECHANICAL SCHEDULES MD.01 MECHANICAL ROOF DEMOLITION PLAN M2.00 GARAGE PLUMBING PLAN M2.01 FIRST FLOOR PLUMBING PLAN M2.02 SECOND FLOOR PLUMBING PLAN M3.00 GARAGE HVAC PLAN M3.01 FIRST FLOOR HVAC PLAN M3.02 SECOND FLOOR HVAC PLAN M3.03 MECHANICAL ROOF PLAN M7.00 GARAGE FIRE SPRINKLER PLAN M7.01 FIRST FLOOR FIRE SPRINKLER PLAN M7.02 SECOND FLOOR FIRE SPRINKLER PLAN GENERAL NOTES: C©de-,z_A- o' m -z-oiy 1A c-, G as s q,+c,t14- 5-Avaw-z& GENERAL: 3. VALVES (EXCEPT CONTROL VALVES) AND STRAINERS SHALL BE FULL SIZE OF PIPE BEFORE REDUCING SIZE TO MAKE 1: COORDINATE MECHANICAL WORK WITH ELECTRICAL, CONNECTIONS TO EQUIPMENT AND CONTROLS. ARCHITECTURAL, STRUCTURAL, CIVIL AND LANDSCAPE WORK Z SHOWN ON OTHER CONTRACT DOCUMENTS. PROVIDE 4. PROVIDE UNIONS AND/OR FLANGES AT EACH PIECE OF ADDITIONAL OFFSETS FOR COORDINATED INSTALLATION EQUIPMENT, AT EACH CONTROL VALVE, IN BYPASSES, AND IN WHERE REQUIRED. LONG PIPING RUNS (100 FEET OR MORE) TO PERMIT DISASSEMBLY FOR ALTERATION AND REPAIRS. 2. COORDINATE HVAC, PLUMBING AND FIRE PROTECTION WORK m PRIOR TO INSTALLATION. DUCTWORK AND EQUIPMENT 5. PROVIDE FLEXIBLE CONNECTORS IN PIPING SYSTEMS ACCESS TAKES PRECEDENCE OVER PIPING FOR AVAILABLE CONNECTED TO AIR HANDLING EQUIPMENT; PUMPS, CHILLERS, SPACE. COOLING TOWERS, AND OTHER EQUIPMENT WHICH REQUIRE �-- VIBRATION ISOLATION. 3. WHERE USED, THE TERM "PROVIDE" SHALL MEAN "FURNISH U® 'AND INSTALL". 6. PROVIDE LINE SIZE STRAINER UPSTREAM OF EACH BACKFLOW 0o PREVENTER, WATER PRESSURE REDUCING VALVE, AUTOMATIC 4. MAINTAIN A MINIMUM.OF 6'-8" CLEARANCE TO UNDERSIDE OF FLOW CONTROL VALVE, CONTROL VALVE, SOLENOID VALVE, DUCTS, PIPES, CONDUITS, SUSPENDED EQUIPMENT, ETC., IN GAS PRESSURE REGULATOR, AND PUMP. PROVIDE SHUTOFF MECHANICAL ROOM ACCESS SPACES. r VALVE ON EACH SIDE OF STRAINER. 5. COORDINF I E EQUIPMENT CONNECTIONS WITH 7. VALVES, EXPANSION FITTINGS/LOOPS, AND PIPING MANUFACTURERS' CERTIFIED DRAWINGS. COORDINATE AND SPECIALTIES SHALL BE FULL SIZE OF PIPE UNLESS NOTED PROVIDE DUCT AND PIPING TRANSITIONS REQUIRED FOR FINAL OTHERWISE. EQUIPMENT CONNECTIONS TO FURNISHED EQUIPMENT. FIELD VERIFY AND COORDINATE DUCT AND PIPING DIMENSIONS HVAC/SHEET METAL: BEFORE FABRICATION. 1. DUCTWORK DIMENSIONS, AS SHOWN ON THE DRAWINGS, ARE 6. PROVIDE 4" MINIMUM CONCRETE BASES (HOUSEKEEPING INTERNAL CLEAR DIMENSIONS AND DUCT SIZE SHALL BE PADS) UNDER FLOOR MOUNTED MECHANICAL EQUIPMENT. INCREASED TO COMPENSATE FOR DUCT LINING THICKNESS. THIS INCLUDES, BUT IS NOT LIMITED TO BOILERS, CHILLERS, 2. PROVIDE TEMPORARY COVERS OVER OPEN ENDS OF FLUID COOLERS, COOLING TOWERS, PUMPS, EXPANSION EQUIPMENT AND DUCTWORK DURING CONSTRUCTION. TANKS, WATER HEATERS, AND STORAGE TANKS. COMPLY WITH REQUIREMENTS FOR EQUIPMENT BASES AND 3. PROVIDE MANUAL VOLUME DAMPER FOR EACH DIFFUSER, FOUNDATIONS' SPECIFIED IN DIVISION 03. REGISTER, AND GRILLE. 7. PROVIDE MISCELLANEOUS STEEL REQUIRED TO ENSURE 4. PROVIDE DUCT ACCESS DOORS AT DUCT SMOKE DETECTORS, PROPER INSTALLATION OF MECHANICAL SYSTEMS. BACKDRAFT DAMPERS, MOTORIZED CONTROL DAMPERS, FIRE 8. LOCATE VALVES, WATER HAMMER ARRESTERS, CLEANOUTS, DAMPERS, SMOKE DAMPERS, COMBINATION FIRE/SMOKE DAMPERS, CONTROLS AND SIMILAR COMPONENTS SO THAT DAMPERS, DUCT MOUNTED COILS, DUCT AIRFLOW STATIONS THEY ARE ACCESSIBLE. PROVIDE ACCESS DOORS FOR AND LOUVER PLENUMS. MECHANICAL EQUIPMENT INSTALLED BEHIND WALLS, ABOVE 5. PROVIDE THE FOLLOWING MINIMUM BRANCH DUCT SIZE TO INACCESSIBLE CEILINGS AND BELOW FLOORS. COORDINATE DIFFUSERS, REGISTERS, AND GRILLES, UNLESS NOTED TO USE ACCESS DOOR LOCATIONS WITH ARCHITECT/ENGINEER. LARGER SIZE ON DRAWINGS: INSTALL TAG ON CEILING GRID FRAME TO INDICATE LOCATION AND TYPE OF EQUIPMENT THAT REQUIRES MAINTENANCE. 5.1. 6"0: 100 CFM PROVIDE 16 GA, STEEL, FLUSH TYPE ACCESS DOOR WITH 5.2. 8"0": 200 CFM CONCEALED HINGE AND SLOT SCREWDRIVER TYPE CAM 5.3. IWO: 300 CFM LATCH. PROVIDE FACTORY PRIMED IN PAINTED SURFACE 5.4. 12"0: 450 CFM AREAS FOR FIELD PAINTING. PROVIDE STAINLESS STEEL FOR 5.5. 14"0: 600 CFM ALL OTHER AREAS. PROVIDE UL LISTED AND LABELED DOOR 5.6. 16"0: 750 CFM WHERE FIRE -RESISTANCE RATING IS INDICATED ON DRAWINGS. ACCESS DOCR SHALL BE SIZED SO THAT ADJACENT ENERGY CODE: (WASHINGTON STATE ENERGY CODE) EQUIPMENT is ACCESSIBLE. PROVIDE ACUDOR, ELMDOR, 1. MOTORS: COMPLY WITH MINIMUM FULL LOAD EFFICIENCIES MILCOR, OR APPROVED. LISTED IN THE WASHINGTON STATE ENERGY CODE. 9. COORDINATE ATTACHMENTS TO STRUCTURE TO VERIFY THAT 2. PIPING AND DUCT INSULATION: COMPLY WITH THICKNESS AND ATTACHMENT POINTS ON EQUIPMENT AND STRUCTURE CAN TYPES LISTED IN THE WASHINGTON STATE ENERGY CODE. ACCEPT SEISMIC, WEIGHT, AND OTHER LOADS IMPOSED. 3. DUCT SEALING: SEAL DUCT TRANSVERSE JOINTS AND 10. MAINTAIN INDI•^,.aTED FIRE AND SMOKE RATING,OF WALLS, LONGITUDINAL SEAMS PER THE WASHINGTON STATE ENERGY PARTITIONS, CEILINGS, AND FLOORS AT MECHANICAL CODE. PENETRATIONS. SEAL PENETRATIONS WITH FIRESTOP MATERIAL. PROVIDE MATERIAL IN ACCORDANCE WITH ASTM E 4. RECORD DRAWINGS: PROVIDE PER THE WASHINGTON STATE 814 AND UL 1479 3M OR APPROVED. COMPLY WITH ENERGY CODE. REQUIREMENTS SPECIFIED IN DIVISION 07. 5. OPERATION AND MAINTENANCE MANUALS: PROVIDE PER THE 11. REFER TO T Y '!C L DETAILS PROVIDED IN THIS DWG SET FOR WASHINGTON STATE ENERGY CODE. DUCTWORK, PIPING, AND EQUIPMENT INSTALLATION. 6. SYSTEM BALANCING: PROVIDE PER THE WASHINGTON STATE CONTRACTOR IS RESPONSIBLE FOR CONFORMANCE WITH ENERGY CODE. DETAILS. 7. MECHANICAL SYSTEMS COMMISSIONING: PROVIDE PER THE 12. LOCATIONS AND - iZES OF`FLOOR, WALL, AND ROOF OPENINGS WASHINGTON STATE ENERGY CODE. SHALL BE C,^_ LANATED WITH OTHER TRADES INVOLVED. INCLUDE IN THE COST OF MECHA) Alr WORK, CUTTING, 8. THIS BUILDING AND ITS ENERGY SYSTEMS HAVE BEEN -;-! I CORING, PAT•,., ,INC AND PAINT( s EXISTING WADS, NED N STATE DC$IG TO COMPLY WITH THE WASHINGTON ENERGY CEILINGS, FL�70RS AND ROOP QUIRED TO_ CODE`. CONTRACTOR 1S RESPONSIBLE FOR CORRECT . ACCOMMOD:.'`.NORK AS INDICA'r IN THE MECHANICAL ;• INSTALLATION OF ENERGY CONSERVATION MEASURES. CONTRACT G�_.OUMENTS, UNLESS SCIFICALLY SHOWN ON BUILDING PRESSURE TESTING: COORDINATE PHASING OF ARCHITECTUC'AL DRAWINGS, 39. "- BUILDING ENVELOPE LEAKAGE TESTING WITH MECHANICAL 13. PROVIDE ELa." 0MERIC FOAM MATERIAL ON MECHANICAL SYSTEM SCOPES OF WORK. TEMPORARILY CAP SYSTEMS AS EQUIPMENT '_ : %7 PRESENT A SAFETY HAZARD. PAINT FOAM REQUIRED TO FACILITATE LEAKAGE TESTING SCOPE OF WORK. MATEP„AL 4,t :i E. NON-STRUCTURAL MECHANICAL COMPONENTS: 14. THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE 1. THE FOLLOWING ITEMS ARE TAKEN DIRECTLY FROM THE 2012 SAFEKE&ING OF HIS OWN PROPERTY ON THE JOB SITE. INTERNATIONAL BUILDING CODE AND FROM THE AMERICAN OWNER ASSI I?VIES NO RESPONSIBILITY FOR PROTECTION OF SOCIETY OF CIVIL ENGINEERS (ASCE) STANDARD 7-10. THE PROPER i >E.4'-GAINST FIRE, THEFT AND ENVIRONMENTAL CONTRACTOR SHALL REFER TO THE ABOVE FOR ADDITIONAL CONDITIONS. INFORMATION, EXCEPTIONS, AND FURTHER DESCRIPTIONS. 15. CLEAN THE JOB SITE DAILY AND REMOVE FROM THE PREMISES THE CONTRACTOR SHALL ADHERE TO REQUIREMENTS AND AS ANY DIRT AND DEBRIS CAUSE BY THE PERFORMANCE OF THE SUCH, SHALL BE INCLUDED WITHIN BID. WORK INCLUDED IN THIS CONTRACT. BEFORE SUBSTANTIAL 2. 2012 IBC 1613.1 SCOPE: ARCHITECTURAL, MECHANICAL, COMPLETION, CLEAN EQUIPMENT, FIXTURES, EXPOSED DUCTS, ELECTRICAL, AND NON-STRUCTURAL COMPONENTS THAT ARE PIPING AND SIMILAR ITEMS. PERMANENTLY ATTACHED TO STRUCTURES AND THEIR 16. PROVIDE EQUIPMENT THAT FITS INTO THE SPACE ALLOTTED SUPPORTS AND ATTACHMENTS SHALL BE DESIGNED AND AND ALLOWS ADEQUATE ACCEPTABLE CLEARANCE FOR CONSTRUCTED TO RESIST THE EFFECTS OF EARTHQUAKE INSTALLATION, REPLACEMENT, ENTRY, SERVICING AND MOTIONS IN ACCORDANCE WITH ASCE 7-10, EXCLUDING MAINTENANCE. COORDINATE WITH OTHER TRADES TO ENSURE CHAPTER 14 AND APPENDIX 11A. NO CONFLICT WITH REQUIRED CLEARANCES. 3. 2012 IBC 1705.11 CONTRACTOR RESPONSIBILITY: THE 17. PROVIDE OFFSETS IN PIPING WHERE PLUMBING/PIPING CONTRACTOR SHALL BE RESPONSIBLE FOR THE DESIGN AND WALL IS LOCATED DIRECTLY ABOVE STRUCTURE. CONSTRUCTION OF A SEISMIC -FORCE -RESISTING SYSTEM, OFFSET PIPING INTO CASEWORK OR SHAFT TIGHT TO DESIGNATED SEISMIC SYSTEM, OR SEISMIC -RESISTING WALL AND BACK INTO WALL ONCE BELOW STRUCTURE. COMPONENT LISTED IN THE STATEMENT OF SPECIAL REFER TO STRUCTURAL DRAWINGS. INSPECTIONS. 4. HANGERS AND SEISMIC BRACING FOR THE MECHANICAL 18. BUILDING SPACE IS LIMITED. STRONG ATTENTION TO SYSTEMS SHALL BE DESIGNED AND PROVIDED BY THE DETAIL AND MARE MUST BE TAKEN WHEN DEVELOPING MECHANICAL CONTRACTOR. REFER TO CONTRACTOR SHOP SHOP: DRAWING SO ROUTING IS COORDINATED WITH DRAWINGS FOR LOCATIONS OF EQUIPMENT AND HUNG OTHER DISCIPLINES. MECHANICAL SYSTEMS. THE MECHANICAL CONTRACTOR 19. MATERIALS WITHIN PLENUMS SHALL BE SHALL COORDINATE THE SUPPORT SYSTEMS AND DESIGN LOADS FOR HUNG MECHANICAL SYSTEMS WITH THE GENERAL NONCOMBU��TIBLE OR SHALL HAVE A FLAME SPREAD CONTRACTOR AND OTHER TRADES THAT MAY BE IMPACTED. INDEX OF NOT MORE THAN 25 AND A SMOKE -DEVELOPED 0 N INDEX OF NOT MORE THAN 50 WHEN TESTED IN EXISTING MECHANICAL: ACCORDANCE WITH ASTM E 84 OR UL 723. 1. WORK SHALL BE PERFORMED IN A CLEAN AND WORKMANLIKE 20. MECHANICAL EQUIPMENT, PACKAGED UNITS, CONTROL MANNER. CARE SHALL BE EXERCISED TO MINIMIZE ANY INCONVENIENCE OR DISTURBANCE TO OTHER AREAS OF THE PANELS, MOTOR STARTER, MOTOR CONTROLLERS, BUILDING WHICH ARE TO REMAIN IN OPERATION. ISOLATE VARIABLE FREQUENCY DRIVES AND SIMILAR EQUIPMENT WORK AREAS BY MEANS OF TEMPORARY PARTITIONS AND/OR SHALL CARR'' A SHORT CIRCUIT CURRENT RATING (SCCR) TARPS TO KEEP DUST AND DIRT WITHIN THE CONSTRUCTION EQUAL TO OR GREATER THAN AVAILABLE FAULT AREA. CURRENT DELIVERED FROM ELECTRICAL SYSTEM. INCLUDE VISIBLE FACTORY NAMEPLATE FOR SUCH 2. EXISTING MATERIALS THAT ARE REMOVED SHALL NOT BE r 00 REUSED IN NEW SYSTEMS, EXCEPT WHERE INDICATED AS EQUIPMENT INDICATING SCCR OF EQUIPMENT IN BEING RELOCATED. ACCORDANCE WITH UL 1995 AND UL 508A. 3. WHERE INDICATED, DUCTWORK AND PIPING OR PORTIONS OF PLUMBING: DUCTWORK AND PIPING SHALL BE REUSED. REFER TO 1. DOMESTIMATER TUBE, PIPE, FITTINGS, JOINING MATERIALS, DRAWING PLANS FOR POINTS OF CONNECTIONS. SPECIALTIES,` PLUMBING EQUIPMENT, PLUMBING FIXTURES, 4. PROVIDE TEMPORARY SUPPORT OF EXISTING MECHANICAL PLUMBING F!TT NGS AND ALL OTHER APPURTENANCES IN SYSTEMS WHERE REQUIRED BY DEMOLITION OR ALTERATION CONTACT WITH DRINKING WATER SHALL BE LEAD-FREE OF EXISTING STRUCTURE DURING CONSTRUCTION. EXCEPT THOSIH EXPLICITLY EXEMPTED IN SECTION 3874 OF COORDINATE WITH GENERAL CONTRACTOR AND PROVIDE ALL THE SAFE WATER DRINKING ACT. LEAD-FREE SHALL MEAN (A) NECESSARY PIPE, DUCT AND EQUIPMENT SUPPORTS AND NOT CONTAINING MORE THAN 0.2 PERCENT LEAD WHEN USED HANGERS TO MAINTAIN INTEGRITY, SAFETY AND PROPER WITH RESPECT TO SOLDER AND FLUX; AND (B) NOT MORE OPERATION OF EXISTING MECHANICAL SYSTEMS FOR THE THAN A WEIGHTED AVERAGE OF 0.25 PERCENT LEAD WHEN DURATION OF THE WORK. USED WITH PR3PECT TO WETTED SURFACES OF DOMESTIC WATER TUBE, PIPE, FITTINGS, JOINING MATERIALS, DEMOLITION: SPECIALTIES, PLUMBING EQUIPMENT, PLUMBING FIXTURES, 1. TAKE CAUTION IN DEMOLITION OF MECHANICAL EQUIPMENT. AND PLUMBING FITTINGS. 2. CONTRACTOR SHALL REMOVE ALL PIPING, DUCTWORK, AND 2. PROVIDE WATER HAMMER ARRESTORS IN DOMESTIC WATER EQUIPMENT INDICATED ON DRAWINGS INCLUDING ALL PIPING IN ACCORDANCE WITH PDI -WH 201. ASSOCIATED INSULATION, HANGERS, VALVES, PLENUM WALLS, 3. PROVIDE LINE SIZE STRAINER UPSTREAM OF EACH BACKFLOW DAMPERS, WIREMOLD, WIRING, CONTROLS, AND PREVENTER, WATER PRESSURE REDUCING VALVE, CONTROL APPURTENANCES ASSOCIATED WITH EACH PIECE OF VALVE, SOLENOID VALVE AND PUMP. PROVIDE SHUTOFF EQUIPMENT. VALVE ON EA:.!-! SIDE OF STRAINER. 3. EXISTING CONTROL PATHWAYS MAY BE RE -USED. 4. VALVES, EXPANSION FITTINGS/LOOPS, AND PIPING COORDINATE CONTROLS DEMO WORK PRIOR TO DEMOLITION. SPECIALTIES SHALL BE FULL SIZE OF PIPE UNLESS NOTED REMOVE ALL EXISTING THERMOSTATS SHOWN ON THE OTHERWISE. DRAWINGS ALONG WITH ASSOCIATED WIRING AND RACEWAYS. PIPING: 4. WHERE EXISTING ITEMS PENETRATE A WALL OR ROOF, 1. PROVIDE AN AUTOMATIC AIR VENT AT THE HIGH POINT OF CONTRACTOR SHALL PROVIDE INFILL AT (E) PENETRATIONS EACH DROP IN THE HEATING WATER, CHILLED WATER, AND THROUGH WALL/ROOF WITH LIKE MATERIALS. PATCH & REPAIR OTHER CLOSED WATER PIPING SYSTEMS. PIPE VENT TO TO MATCH SURROUNDING SURFACES INCLUDING PAINT. NEAREST DR.5iN. PIPING SHALL GRADE TO LOW POINTS. PROVIDE HOSE END DRAIN VALVES AT THE BOTTOM OF RISERS 5. CONTRACTOR SHALL PROVIDE TEMPORARY SUPPORT OF AND LOW POR --:TS EXISTING MECHANICAL EQUIPMENT WHERE REQUIRED BY DEMOLITION OR ALTERATION OF EXISTING STRUCTURE 2. VALVES SHALL BE INSTALLED SO THAT VALVE REMAINS IN DURING CONSTRUCTION. COORDINATE WITH GC AND PROVIDE SERVICE WHEN EQUIPMENT OR PIPING ON EQUIPMENT SIDE OF NECESSARY SUPPORTS AND HANGERS TO MAINTAIN VALVE IS REMOVED. INTEGRITY, SAFETY AND PROPER OPERATION OF EXISTING MECHANICAL SYSTEMS. JACKSON ) MAIN ARCHITECTURE 311 FIRST AVENUE SOUTH SEATTLE, -WA 98104 t 206.324.4800 WWW.JACKSONMAIN.COM z O JCO Z axµ d m co LU co m ao Q 1= a �W� z �-- LU W 00 a_O U® C) z WM 0o VJ 0 N U) W F- ) 0 J n N LO O z O Z 0 i- Z m ao 1= a �-- LU W 00 a_O U® C) z WM 0o VJ W F- Q 0 J n i.� O O L0I- W z 0 1= a U W W U ZW�cn z W W � � U) WIw Q O W W W W2 U W W W Q� Q�oQ�acn gpzol-r- W0(9Ug� U p W Q W W Z r N Ch 'IT to LO CD C.0 r (0 r cc r CD r (0 Wr F- 0 N 0 N 0 N 0 N O N 0 N QCO CD C co C, r I_ r 00 co r r r r \. r ' �GisTE¢�'' J`SIONAL ti�G PROJECT NO.: 16025 PROJECT MGR.: SM DRAWN BY: BD CHECKED BY: SM LEGEND AND NOTES - MECHANICAL VRF BRANCH SELECTOR SCHEDULE TAG AREA SERVED ASSOCIATED HEAT PUMP UNIT MANUFACTURER/MODEL TYPE NUMBER OF MCA VOLTAGE/ PORTS PHASE # A V/QJ DIMENSIONS (LxWxHT) INANAN WEIGHT LBS NOTES BS -101 LEVEL 1 HP -01 MITSUBISHI / CMB -P1 01 6NU-HA MAIN 16 1.65 208/1 48x18x12 175 - BS -102 LEVEL 1 HP -01 MITSUBISHI / CMB-P104NU-GB SUB 4 0.32 208/1 29x15x12 65 - BS -103 LEVEL 1 HP -02 MITSUBISHI / CMB-P1016NU-HA MAIN 16 1.65 208/1 48x18x12 175 - BS -104 LEVEL 1 HP -02 MITSUBISHI / CMB-P108NU-GB1 SUB 8 0.64 208/1 48x18x12 125 - BS -201 LEVEL 2 HP -03 MITSUBISHI / CMB -P1 01 6NU-HA MAIN 16 1.65 208/1 48x18x12 175 - BS -202 LEVEL 2 HP -03 MITSUBISHI / CMB -P1 01 6NU-HA SUB 16 0.32 208/1 48x18x12 175 - BS -203 LEVEL 2 HP -03 MITSUBISHI / CMB-P104NU-GB1 SUB 4 1.65 208/1 29x15x12 65 - BS -204 LEVEL 2 HP -04 MITSUBISHI / CMB-P1016NU-HB1 MAIN 16 1.46 208/1 48x18x12 175 - BS -205 LEVEL 2 HP -04 MITSUBISHI / CMB-P104NU-GB1 SUB 4 1.65 208/1 29x15x12 65 - MITSUBISHI PMFY-P06NBMU-ER5 PLUMBING FIXTURE SCHEDULE TAG FIXTURE TAG NOTES W V CW HW P -1A WATER CLOSET 4" 2" 1-1/2" - - P-1 WATER CLOSET 4" 2" 1-1/2" - - P-2 URINAL 2" 2" 1/2" - - P-3 LAVATORY 2" 2" 1/2" 1/2" 1 P-4 SHOWER 2-' 2" 1/2" 1/2" 1 P-5 KITCHEN SINK 2" 2" 1/2" 1/2" 1 TP TRAP PRIMER - - 1/2" - - FD FLOOR DRAIN 2" 2" - - - FS FLOOR SINK 4" 2" MITSUBISHI PMFY-P06NBMU-ER5 CEILING CASSETTE 310 230 1 DIRECT 6.7 6 4.9 0.25 NOTES: 1) PROVIDE WITH INDIVIDUAL FIXTURE WATER TEMPERING VALVES. PUMP SCHEDULE AREA SERVED TAG SYSTEM SERVED LOCATION MANUFACTURER / MODEL WEIGHT LB ELECTRICAL NOTES HP HP RPM RPM FLA AMPS VOLTAGE/PHASE V/0 CP -1 DOMESTIC HOT WATER KITCHEN BELL & GOSSETT / SERIES 100 1/12 1725 1.75 120/1 1 H CFM L CFM NOTES: 1) PROVIDE WITH 18" RISER TO ACCOMMODATE INVERT ELEVATION OF GARAGE DRAIN INLET (36" BFF). BANKING 100 BS -101 U� MITSUBISHI PLFY-P18NBMU-ER2 CEILING CASSETTE 620 NOTES: 1) PROVIDE WITH PROGRAMMABLE TIMER CONTROLS FOR PROGRAMMED SHUTDOWN. 1 OIL WATER SEPARATOR SCHEDULE TAG AREA SERVED LOCATION MANUFACTURER / MODEL CAPACITY GALLONS DIMENSIONS LXWxH WEIGHT LB NOTES OWS-1 GARAGE GARAGE OLDCASTLE / 660 -SA 450 6'-0" x 4'-0" x 6'-0" 11,000 1 MOTOR DRIVE TOTAL CAPACITY MBH SENSIBLE CAPACITY MBH MCA A VOLTAGE/ PHASE V/0 HIGH FLOW dB(A) H CFM L CFM NOTES: 1) PROVIDE WITH 18" RISER TO ACCOMMODATE INVERT ELEVATION OF GARAGE DRAIN INLET (36" BFF). EXPANSION TANK SCHEDULE TAG TAG SYSTEM SERVED LOCATION MANUFACTURER / MODEL VOLUME GAL SYSTEM CONN IN NOTES ET -1 DOMESTIC HOT WATER KITCHEN AMTROL / THERM-X-TROL ST -25V 10.3 3/4 # PUMPS # QUANTITY # MOTOR DRIVE TOTAL CAPACITY MBH SENSIBLE CAPACITY MBH MCA A VOLTAGE/ PHASE V/0 HIGH FLOW dB(A) H CFM L CFM a 0 O G) 0 CD 0 N d' N 00 VRF FAN COIL UNIT SCHEDULE TAG AREA SERVED ASSOCIATED VRF HEAT RECOVERY UNIT ASSOCIATED ENERGY RECOVERY VENTILATOR MANUFACTURER/MODEL TYPE T HEATING CAPACITY MBH COOLING SOUNE PRESSURE I.EVEMNSIONS (LxWxH) INANAN WEIGHT LBS ECONOMIZER (NOTE 5) /N NOTES # PUMPS # QUANTITY # MOTOR DRIVE TOTAL CAPACITY MBH SENSIBLE CAPACITY MBH MCA A VOLTAGE/ PHASE V/0 HIGH FLOW dB(A) H CFM L CFM FCU -101 BANKING 100 BS -101 U� MITSUBISHI PLFY-P18NBMU-ER2 CEILING CASSETTE 620 500 1 DIRECT 20 18 13.2 0.64 208/1 30 33x33x11 55 N 1,2,3,4 FCU -102 BANKING 100 BS -101 MITSUBISHI PLFY-P18NBMU-ER2 CEILING CASSETTE 620 500 1 DIRECT 20 18 13.2 0.64 208/1 30 33x33x11 55 N 1,2,3,4 FCU -103 CONFERENCE 102 BS -101 MITSUBISHI PMFY-P06NBMU-ER5 CEILING CASSETTE 310 230 1 DIRECT 6.7 6 4.9 0.25 208/1 28 32x16x9 35 N 1,2,3,4 FCU -104 CONFERENCE 104 BS -101 MITSUBISHI PMFY-P06NBMU-ER5 CEILING CASSETTE 310 230 1 DIRECT 6.7 6 4.9 0.25 208/1 28 32x16x9 35 N 1,2,3,4 FCU -105 CONFERENCE 121 BS -101 MITSUBISHI PMFY-P06NBMU-ER5 CEILING CASSETTE 310 230 1 DIRECT 6.7 6 4.9 0.25 208/1 28 32x16x9 35 N 1,2,3,4 FCU -106 CONFERENCE 122 BS -101 MITSUBISHI PMFY-P06NBMU-ER5 CEILING CASSETTE 310 230 1 DIRECT 6.7 6 4.9 0.25 208/1 28 32x16x9 35 N 1,2,3,4 FCU -107 CONFERENCE 123 BS -101 MITSUBISHI PMFY-P06NBMU-ER5 CEILING CASSETTE 310 230 1 DIRECT 6.7 6 4.9 0.25 208/1 28 32x1 6x9 35 N 1,2,3,4 FCU -108 CONFERENCE 124 BS -101 MITSUBISHI PMFY-P06NBMU-ER5 CEILING CASSETTE 310 230 1 DIRECT 6.7 6 4.9 0.25 208/1 28 32x16x9 35 N 1,2,3,4 FCU -109 GYM 114 BS -101 U MITSUBISHI PLFY-P24NBMU-ER2 CEILING CASSETTE 710 530 1 DIRECT 27 24 16.2 0.64 208/1 30 33x33x11 55 N 1,2,3,4 FCU -110 GYM 114 BS -101 MITSUBISHI PLFY-P24NBMU-ER2 CEILING CASSETTE 710 530 1 DIRECT 27 24 16.2 0.64 208/1 30 33x33x11 55 N 1,2,3,4 FCU -111 KITCHEN BS -101 MITSUBISHI PMFY-P06NBMU-ER5 CEILING CASSETTE 310 230 1 DIRECT 6.7 6 4.9 0.25 208/1 28 32x16x9 35 N 1,2,3,4 FCU -112 MECHANICAL 113 BS -101 N (0 MITSUBISHI PMFY-P06NBMU-ER5 CEILING CASSETTE 310 230 1 DIRECT 6.7 6 4.9 0.25 208/1 28 32x16x9 35 N 1,2,3,4 FCU -113 OFFICE 101 BS -101 MITSUBISHI PMFY-P06NBMU-ER5 CEILING CASSETTE 310 230 1 DIRECT 6.7 6 4.9 0.25 208/1 28 32x16x9 35 N 1,2,3,4 FCU7114 OPEN OFFICE 103 BS -101 MITSUBISHI PLFY-P24NBMU-ER2 CEILING CASSETTE 710 530 1 DIRECT 27 24 16.2 0.64 208/1 30 33x33x11 55 N 1,2,3,4 FCU -115 OPEN OFFICE 103 BS -101 MITSUBISHI PLFY-P24NBMU-ER2 CEILING CASSETTE 710 530 1 DIRECT 27 24 16.2 0.64 208/1 30 33x33x11 55 N 1,2,3,4 FCU -116 OPEN OFFICE 110 BS -101 MITSUBISHI PLFY-P24NBMU-ER2 CEILING CASSETTE 710 530 1 DIRECT 27 24 16.2 0.64 208/1 30 33x33x11 55 N 1,2,3,4 FCU -117 OPEN OFFICE 110 BS -101 MITSUBISHI PLFY-P24NBMU-ER2 CEILING CASSETTE 710 530 1 DIRECT 27 24 16.2 0.64 208/1 30 33x33x11 55 N 1,2,3,4 FCU -118 OPEN OFFICE 110 BS -101 MITSUBISHI PLFY-P24NBMU-ER2 CEILING CASSETTE 710 530 1 DIRECT 27 24 16.2 0.64 208/1 30 33x33x11 55 N 1,2,3,4 FCU -119 WORKROOM BS -101 MITSUBISHI PMFY-P06NBMU-ER5 CEILING CASSETTE 310 230 1 DIRECT 6.7 6 4.9 0.25 208/1 28 32x16x9 35 N 1,2,3,4 FCU -120 LOUNGE BS -101 MITSUBISHI PMFY-P06NBMU-ER5 CEILING CASSETTE 310 230 1 DIRECT 6.7 6 4.9 0.25 208/1 28 32x16x9 35 N 1,2,3,4 FCU -121 BREAK ROOM BS -101 MITSUBISHI PMFY-P12NBMU-ER2 CEILING CASSETTE 500 390 1 DIRECT 12 13.5 9.2 0.64 208/1 28 33x33x11 35 N 1,2,3,4 FCU -122 BREAK ROOM BS -101 MITSUBISHI PMFY-P12NBMU-ER2 CEILING CASSETTE 500 390 1 DIRECT 12 13.5 'i 9.2 0.64 208/1 28 33x33x11 35 N 1,2,3,4 FCU -123 BREAK ROOM BS -101 MITSUBISHI PMFY-P12NBMU-ER2 CEILING CASSETTE 500 390 1 DIRECT 12 13.5 9.2 0.64 208/1 28 33x33x11 35 N 1,2,3,4 FCU -124 WAREHOUSE 151 BS -102 MITSUBISHI PMFY-P12NBMU-ER2 CEILING CASSETTE 500 390 1 DIRECT 12 13.5 9.2 0.64 208/1 28 33x33x11 35 N 1,2,3,4 FCU -125 WAREHOUSE 151 BS -102 MITSUBISHI PMFY-P12NBMU-ER2 CEILING CASSETTE 500 390 1 DIRECT 12 13.5 9.2 0.64 208/1 28 33x33x11 35 N 1,2,3,4 FCU -126 WAREHOUSE 151 BS -102 MITSUBISHI PMFY-P12NBMU-ER2 CEILING CASSETTE 500 390 1 DIRECT 12 13.5 9.2 0.64 208/1 28 33x33x11 35 N 1,2,3,4 FCU -127 COPY ROOM 155 BS -102 MITSUBISHI PMFY-P12NBMU-ER2 CEILING CASSETTE 500 390 1 DIRECT 12 13.5 9.2 0.64 208/1 28 33x33x11 35 N 1,2,3,4 FCU -128 DEMO ROOM BS -102 MITSUBISHI PMFY-P12NBMU-ER2 CEILING CASSETTE 500 390 1 DIRECT 12 13.5 9.2 0.64 208/1 28 33x33x11 35 N 1,2,3,4 FCU -129 ISA OFFICE BS -102 MITSUBISHI PMFY-P06NBMU-ER5 CEILING CASSETTE 310 230 1 DIRECT 6.7 6 4.9 0.25 208/1 28 32x16x9 35 N 1,2,3,4 FCU -130 KITCHEN 153 BS -102 MITSUBISHI PMFY-P06NBMU-ER5 CEILING CASSETTE 310 230 1 DIRECT 6.7 6 4.9 0.25 208/1 28 32x16x9 35 N 1,2,3,4 FCU -131 MENS LOCKER ROOM BS -102 MITSUBISHI PMFY-P06NBMU-ER5 CEILING CASSETTE 310 230 1 DIRECT 6.7 6 4.9 0.25 208/1 28 32x16x9 35 N 1,2,3,4 FCU -132 NEOPOST RECEPTION 152 BS -102 MITSUBISHI PMFY-P12NBMU-ER2 CEILING CASSETTE 500 390 1 DIRECT 12 13.5 9.2 0.64 208/1 28 33x33x11 35 N 1,2,3,4 FCU -133 NEOPOST RECEPTION 152 BS -102 MITSUBISHI PMFY-P12NBMU-ER2 CEILING CASSETTE 500 390 1 DIRECT 12 13.5 9.2 0.64 208/1 28 33x33x11 35 N 1,2,3,4 FCU -134 WOMENS LOCKER ROOM BS -102 MITSUBISHI PMFY-P06NBMU-ER5 CEILING CASSETTE 310 230 1 DIRECT 6.7 6 4.9 0.25 208/1 28 32x16x9 35 N 1,2,3,4 FCU -135 OFFICE 157 BS -102 MITSUBISHI PMFY-P06NBMU-ER5 CEILING CASSETTE 310 230 1 DIRECT 6.7 6 4.9 0.25 208/1 28 32x16x9 35 N 1,2,3,4 FCU -136 OFFICE 158 BS -102 MITSUBISHI PMFY-P06NBMU-ER5 CEILING CASSETTE 310 230 1 DIRECT 6.7 6 4.9 0.25 208/1 28 32x16x9 35 N 1,2,3,4 FCU -137 OFFICE 159 BS -102 MITSUBISHI PMFY-P06NBMU-ER5 CEILING CASSETTE 310 230 1 DIRECT 6.7 6 4.9 0.25 208/1 28 32x16x9 35 N 1,2,3,4 FCU -138 OFFICE 160 BS -102 MITSUBISHI PMFY-P06NBMU-ER5 CEILING CASSETTE 310 230 1 DIRECT 6.7 6 4.9 0.25 208/1 28 32x16x9 35 N 1,2,3,4 FCU -139 OFFICE 161 BS -102 MITSUBISHI PMFY-P06NBMU-ER5 CEILING CASSETTE 310 230 1 DIRECT 6.7 6 4.9 0.25 208/1 28 32x16x9 35 N 1,2,3,4 FCU -140 CONFERENCE 162 BS -102 MITSUBISHI PMFY-P12NBMU-ER2 CEILING CASSETTE 500 390 1 DIRECT 12 13.5 9.2 0.64 208/1 28 33x33x11 35 N 1,2,3,4 FCU -141 OPEN OFFICE 120 BS -102 MITSUBISHI PLFY-P30NBMU-ER2 CEILING CASSETTE 780 560 1 DIRECT 30 34 19.3 0.64 208/1, 30 33x33x11 55. N 1,2,3,4 FCU -142 OPEN OFFICE 120 BS -102 MITSUBISHI PLFY-P30NBMU-ER2 CEILING CASSETTE 780 560 1 DIRECT 30 34 19.3 0.64 208/1 30 33x33x11 55 N 1,2,3,4 FCU -143 OPEN OFFICE 154 BS -102 MITSUBISHI PLFY-P30NBMU-ER2 CEILING CASSETTE 780 560 1 DIRECT 30 34 19.3 0.64 208/1 30 33x33x11 55 N 1,2,3,4 FCU -144 OPEN OFFICE 154 BS -102 MITSUBISHI PLFY-P30NBMU-ER2 CEILING CASSETTE 780 560 1 DIRECT 30 34 19.3 0.64 208/1 30 33x33x11 55 N 1,2,3,4 FCU -201 CONFERENCE 200 BS -201 MITSUBISHI PLFY-P24NBMU-ER2 CEILING CASSETTE 710 530 1 DIRECT 27 24 16.2 0.64 208/1 30 33x33x11 55 N 1,2,3,4 FCU -202 CONFERENCE 225 BS -201 MITSUBISHI PMFY-P06NBMU-ER5 CEILING CASSETTE 310 230 1 DIRECT 6.7 6 4.9 0.25 208/1 28 32x16x9 35 N 1,2,3,4 FCU -203 KITCHEN 225 BS -201 MITSUBISHI PMFY-P06NBMU-ER5 CEILING CASSETTE 310 230 1 DIRECT 6.7 6 4.9 0.25 208/1 28 32x16x9 35 N 1,2,3,4 FCU -204 OFFICE 201 BS -201 MITSUBISHI PMFY-P06NBMU-ER5 CEILING CASSETTE 310 230 1 DIRECT 6.7 6 4.9 0.25 208/1 28 32x16x9 35 N 1,2,3,4 FCU -205 OFFICE 202 BS -201 MITSUBISHI PMFY-P12NBMU-ER2 CEILING CASSETTE 500 390 1 DIRECT 12 13.5 9.2 0.64 208/1 28 33x33x11 35 N 1,2,3,4 FCU -206 OFFICE 203 BS -201 MITSUBISHI PMFY-P06NBMU-ER5 CEILING CASSETTE 310 230 1 DIRECT 6.7 6 4.9 0.25 208/1 28 32x16x9 35 N 1,2,3,4 FCU -207 OFFICE 204 BS -201 MITSUBISHI PMFY-P12NBMU-ER2 CEILING CASSETTE 500 390 1 DIRECT 12 13.5 9.2 0.64 208/1 28 33x33x11 35 N 1,2,3,4 FCU -208 OFFICE 205 BS -201 MITSUBISHI PMFY-P06NBMU-ER5 CEILING CASSETTE 310 230 1 DIRECT 6.7 6 1 4.9 0.25 208/1 28 32x16x9 35 N 1,2,3,4 FCU -209 OFFICE 206 BS -201 MITSUBISHI PMFY-P06NBMU-ER5 CEILING CASSETTE 310 230 1 DIRECT 6.7 6 4.9 0.25 208/1 28 32x16x9 35 N 1,2,3,4 FCU -210 OFFICE 207 BS -201 MITSUBISHI PMFY-P06NBMU-ER5 CEILING CASSETTE 310 230 1 DIRECT 6.7 6 4.9 4.9 0.25 208/1 28 32x16x9 35 N 1,2,3,4 FCU -211 OFFICE 208 BS -201 MITSUBISHI PMFY-P06NBMU-ER5 CEILING CASSETTE 310 230 1 DIRECT 6.7 6 0.25 208/1 28 32x16x9 35 N 1,2,3,4 FCU -212 OFFICE 209 BS -201 MITSUBISHI PMFY-P06NBMU-ER5 CEILING CASSETTE 310 230 1 DIRECT 6.7 6 4.9 0.25 208/1 28 32x16x9 35. N 1,2,3,4 FCU -213 OPEN OFFICE 222 BS -201 MITSUBISHI PMFY-P12NBMU-ER2 CEILING CASSETTE 500 390 1 DIRECT 12 13.5 I 9.2 0.64 208/1 28 24x24x11 35 N 1,2,3,4 FCU -214 OPEN OFFICE 222 BS -201 MITSUBISHI PMFY-P12NBMU-ER2 CEILING CASSETTE 500 390 1 DIRECT 12 T 13.5 9.2 0.64 208/1 28 24x24x11 35 N 1,2,3,4 FCU -215 OPEN OFFICE 223 BS -201 MITSUBISHI PMFY-P12NBMU-ER2 CEILING CASSETTE 500 390 1 DIRECT 12 13.5 9.2 0.64 208/1 28 24x24x11 35 N 1,2,3,4 FCU -216 OPEN OFFICE 223 BS -201 MITSUBISHI PMFY-P12NBMU-ER2 CEILING CASSETTE 500 390 1 DIRECT 12 13.5 9.2 0.64 208/1 28 24x24x11 35 N 1,2,3,4 FCU -217 OPEN OFFICE 224 BS -201 MITSUBISHI PMFY-P12NBMU-ER2 CEILING CASSETTE 500 390 1 DIRECT 12 13.5 9.2 0.64 208/1 28 24x24x11 35 N 1,2,3,4 FCU -218 CONFERENCE 241 BS -201 MITSUBISHI PMFY-P06NBMU-ER5 CEILING CASSETTE 310 230 1 DIRECT 6.7 6 4.9 0.25 208/1 28 32x16x9 35 N 1,2,3,4 FCU -219 ACCOUNTING 240 BS -201 MITSUBISHI PLFY-P18NBMU-ER2 CEILING CASSETTE 620 500 1 DIRECT 20 18 13.2 0.64 208/1 30 33x33x11 55 N 1,2,3,4 FCU -220 ACCOUNTING 240 BS -201 MITSUBISHI PLFY-P18NBMU-ER2 CEILING CASSETTE 620 500 1 DIRECT 20 18 13.2 0.64 208/1 30 33x33x11 55 N 1,2,3,4 FCU -221 ACCOUNTING 240 BS -201 MITSUBISHI PLFY-P18NBMU-ER2 CEILING CASSETTE 620 500 1 DIRECT 20 18 13.2 0.64 208/1 30 33x33x11 55 N 1,2,3,4 FCU -222 ACCOUNTING 240 BS -201 MITSUBISHI PLFY-P18NBMU-ER2 CEILING CASSETTE 620 500 1 DIRECT 20 18 13.2 0.64 208/1 30 33x33x11 55 N 1,2,3,4 FCU -223 ACCOUNTING 240 BS -201 MITSUBISHI PLFY-P18NBMU-ER2 CEILING CASSETTE 620 500 1 DIRECT 20 18 13.2 0.64 208/1 30 33x33x11 55 N 1,2,3,4 FCU -224 ACCOUNTING 240 BS -201 MITSUBISHI PLFY-P18NBMU-ER2 CEILING CASSETTE 620 500 1 DIRECT 20 18 13.2 0.64 208/1 30 33x33x11 55 N 1,2,3,4 FCU -225 CONFERENCE 242 BS -201 MITSUBISHI PLFY-P18NBMU-ER2 CEILING CASSETTE 620 500 1 DIRECT 20 18 13.2 0.64 208/1 30 33x33x11 55 N 1,2,3,4 FCU -226 CONFERENCE 242 BS -201 MITSUBISHI PLFY-P18NBMU-ER2 CEILING CASSETTE 620 500 1 DIRECT 20 18 13.2 0.64 208/1 30 33x33x11 55 N 1,2,3,4 FCU -227 CONFERENCE 246 BS -201 MITSUBISHI PMFY-P12NBMU-ER2 CEILING CASSETTE 500 390 1 DIRECT 12 13.5 9.2 0.64 208/1 28 24x24x11 35 N 1,2,3,4 FCU -228 CONFERENCE 247 BS -201 MITSUBISHI PMFY-P06NBMU-ER5 CEILING CASSETTE 310 230 1 DIRECT 6.7 6 4.9 0.25 208/1 28 32x16x9 35 N 1,2,3,4 FCU -229 MAIL ROOM 244 BS -202 MITSUBISHI PMFY-P06NBMU-ER5 CEILING CASSETTE 310 230 1 DIRECT 6.7 6 4.9 0.25 208/1 28 32x16x9 35 N 1,2,3,4 FCU -230 SERVER 290 BS -202 MITSUBISHI PMFY-P06NBMU-ER5 CEILING CASSETTE 310 230 1 DIRECT 6.7 6 4.9 0.25 208/1 28 32x16x9 35 N 1,2,3,4 FCU -231 CONFERENCE 251 BS -202 MITSUBISHI PMFY-P06NBMU-ER5 CEILING CASSETTE 310 230 1 DIRECT 6.7 6 4.9 0.25 208/1 28 32x16x9 35 N 1,2,3,4 FCU -232 CONFERENCE 252 BS -202 MITSUBISHI PMFY-P06NBMU-ER5 CEILING CASSETTE 310 230 1 DIRECT 6.7 6 4.9 0.25 208/1 28 32x16x9 35 N 1,2,3,4 FCU -233 CONFERENCE 253 BS -202 MITSUBISHI PMFY-P06NBMU-ER5 CEILING CASSETTE 310 230 1 DIRECT 6.7 6 4.9 0.25 208/1 28 32x16x9 35 N 1,2,3,4 FCU -234 CONFERENCE 254 BS -202 MITSUBISHI PMFY-P06NBMU-ER5 CEILING CASSETTE 310 230 1 DIRECT 6.7 6 4.9 0.25 208/1 28 32x16x9 35 N 1,2,3,4 FCU -235 CONFERENCE 255 BS -202 MITSUBISHI PMFY-P06NBMU-ER5 CEILING CASSETTE 310 230 1 DIRECT 6.7 6 4.9 0.25 208/1 28 32A 6x9 35 N 1,2,3,4 FCU -236 OPEN OFFICE 250 BS -202 MITSUBISHI PMFY-P12NBMU-ER2 CEILING CASSETTE 500 390 1 DIRECT 12 13.5 9.2 0.64 208/1 28 24x24x11 35 N 1,2,3,4 FCU -237 OPEN OFFICE 250 BS -202 MITSUBISHI PMFY-P12NBMU-ER2 CEILING CASSETTE 500 390 1 DIRECT 12 13.5 9.2 0.64 208/1 28 24x24x11 35 N 1,2,3,4 FCU -238 CONFERENCE 256 BS -202 MITSUBISHI PMFY-P06NBMU-ER5 CEILING CASSETTE 310 230 1 DIRECT 6.7 6 4.9 0.25 208/1 28 32x16x9 35 N 112,3,4 FCU -239 CONFERENCE 257 BS -202 MITSUBISHI PMFY-P06NBMU-ER5 CEILING CASSETTE 310 230 1 DIRECT 6.7 6 4.9 0.25 208/1 28 32A 6x9 35 N 1,2,3,4 FCU -240 CONFERENCE 259 BS -202 MITSUBISHI PMFY-P12NBMU-ER2 CEILING CASSETTE 500 390 1 DIRECT 12 13.5 9.2 0.64 208/1 28 24x24x11 35 N 1,2,3,4 FCU -241 CONFERENCE 262 BS -202 MITSUBISHI PMFY-P06NBMU-ER5 CEILING CASSETTE 310 230 1 DIRECT 6.7 6 4.9 0.25 208/1 28 32A 6x9 35 N 1,2,3,4 FCU -242 OPEN OFFICE 263 BS -202 MITSUBISHI PEFY-P96NMHSU-E DUCTED - MED STATIC 2500 1980 2 DIRECT 96 108 60 8.2 208/1 42 49x44x19 225 N 1,2,3,4 FCU -243 CALL CENTER 245 BS -202 MITSUBISHI PLFY-P24NBMU-ER2 CEILING CASSETTE 710 530 1 DIRECT 27 24 16.2 0.64 208/1 30 33x33x11 55 N 1,2,314 FCU -244 CALL CENTER 245 BS -202 MITSUBISHI PLFY-P24NBMU-ER2 CEILING CASSETTE 710 530 1 DIRECT 27 24 16.2 0.64 208/1 30 33x33x11 55 N 1,2,3,4 FCU -245 CALL CENTER 245 BS -202 MITSUBISHI PLFY-P24NBMU-ER2 CEILING CASSETTE 710 530 1 DIRECT 27 24 16.2 0.64 208/1 30 33x33x11 55 N 1,2,3,4 FCU -246 CALL CENTER 245 BS -202 MITSUBISHI PLFY-P24NBMU-ER2 CEILING CASSETTE 710 530 1 DIRECT 27 24 16.2 0.64 208/1 30 33x33x11 55 N 1,2,3,4 NOTES: REVIEWED FOR 1) 2015 WSEC ECONOMIZER EXCEPTION C403.4.6. BODE COMPLIANCE 2) HEATING CAPACITY IS BASED ON 22°F OUTDOOR AIR TEMPERATURE AND 70°F INDOOR AIR TEMPERATURE. APPROVED 3) COOLING CAPACITIES ARE BASED ON 95°F OUTDOOR AIR TEMPERATURE AND 67-F INDOOR AIR TEMPERATURE. 4) PROVIDE WITH FACTORY CONDENSATE PUMP KIT. •J DEC 0 6 2016 I _'-Em.L-. •I _ I SUMP PUMP SCHEDULE O T z TAG SYSTEM SERVED LOCATION MANUFACTURER / MODEL TOTAL FLOW GPM # PUMPS # PUMP FLOW GPM HEAD FT DISCHARGE SIZE IN 00 MOTOR BASIN LLl NOTES HP `HP SPEED RPM VOLTAGE/PHASE V/0 TYPE U� DIMENSIONS DIA INAN SP -1 � SANITARY GARAGE WEIL / 2526-2" 110 2 55 15 2 3/4 1750 208/3 FIBERGLASS ^- L.�.. 36x84 1 �N O O � D � Gmm O �- O N NOTES:_ 1) PROVIDE WITH NEMA 4 CONTROL PANEL, MAGNETIC CONTACTORS, MAIN DISCONNECT, OVERLOAD PROTECTION, TOA SWITCHES, TRANSFORMER, PILOT LIGHTS, HWA BELL AND HWA DOME LIGHT. FECE1 7-D Cr 1 Y OF TUKWILA Ruv z.1 010 RERP1,4111' CENTER JACKSON I MAIN ARCHITECTURE 311 FIRST AVENUE SOUTH SEATTLE, WA 98104 t 206.324.4800 WWW.JACKSONMAIN.COM T� . 725 Powell Ave SW, SUITE 100 RENTON, WA 98057 425-336-2822 www.metrixeng.com z O z 00 a co µ '9 m 00 00 LLl mam-t _ LLI 11--00 U� p W � L W r Q cn U O ^- L.�.. u- O �N O O � D � Gmm O �- O N LO z O z O a �Z m 00 Ilfco LSI B'- _ LLI 11--00 U� p z w � Q W Q L.L U O ^- L.�.. u- U �N O O � LID �- z O d U U) W W U) U) z I- W � a U) Q w3: 0 ?: p W W W W U W W W Q D Q�o�C1U) gozo�-I- W0(9Ugg = o U) 8 U O W p W W U)CooLno-a zr- N M It to 1'0 (D CD CO CO CO `D W O O O O O O H Q N N r N CD N N N (0 f- CO 00 � I Ll �p 40508 �GISIER� SSIONAL tl�l4�ll PROJECT NO.: 16025 PROJECT MGR.: SM DRAWN BY: BD CHECKED BY: SM MECHANICAL SCHEDULES F JACKSON I MAIN ARCHITECTURE P.S. © 2016 N C) O O 0 N IT N VRF HEAT PUMP UNIT SCHEDULE TAG AREA LOCATION MANUFACTURER/MODEL FAN COMPRESSOR HEATING COOLING DIMENSIONS (LxWXHT) (INANAN) SOUND DIMENSIONS WEIGHT NOTES MOTOR (HP) SERVED COOLING EXTRA HIGH (%) MAX OPERATING CURRENT (AMPS) PRESSURE VOLTAGE PHASE (V/O) EXTRA HIGH AIRFLOW HIGH FLOW QTY TYPE QTY CAPACITY INDOOR COP TOTAL INDOOR EER MCA MOP VOLTAGE/ 2.9 654 208/3 48x45x16 160 1 ERV -102 - MITSUBISHI / LGH-F600RX3-E UNITS 600 CAPACITY UNITS 69 44 39 PHASE LEVELS (LxWxHT) 654 208/3 48x45x16 160 1 ERV -103 CFM # 100 # BTU/H) (% 69 BTU/H) (% 37 AMPS AMPS V/0 (dB(A)) INANAN LBS 1 HP -01 - ROOF MITSUBISHI PURY-P240T 11,300 2 INVERTER 1 270,000 100% 3.42 240,000 100% 10.9 45 50 208/3KMU-A 63 138x30x65 1500 1,2/31 11,300 2 INVERTER 1 45 50 208/3 HP -02 30 ROOF MITSUBISHI PURY-P240TKMU-A 11,300 2 INVERTER 1 270,000 100% 3.42 240,000 100% 10.9 45 50 20/3 63 138x30x65 1500 1,2 7 11,300 2 INVERTER 1 45 50 208/3 HP -@S '03 100 ROOF MITSUBISHI PU 7,750 2 INVERTER 1 200,000 100% 3.42 192,000 100% 10.9 35 40 208/3RY-P192TKMU-A 62 98x30x65 1200 1, 2, 31 7,750 2 INVERTER 1 35 40 208/3 NOTES: 1) HEATING CAPACITY IS BASED ON 22°F OUTDOOR AIR TEMPERATURE AND 70°F INDOOR AIR TEMPERATURE. COP LISTED AT 17°F OUTDOOR AIR TEMPERATURE. Z) COOLING CAPACITIES ARE BASED ON 95°F OUTDOOR AIR TEMPERATURE AND 67°F INDOOR AIR TEMPERATURE. Atra-c---., vroo f -tn f kwf is fa 5firvs-*Ave, �,'v- zk�&tq- ]> z. n ENERGY RECOVERY VENTILATOR SCHEDULE TAG AREA SERVED MANUFACTURER/MODEL OUTSIDE AIR (%) FANS MOTOR _ OPERATING SOUND DURING HEAT EXCHANGER MODE (dB(A)) ELECTRICAL DIMENSIONS (LxWXHT) (INANAN) WEIGHT (LBS) NOTES AIRFLOW (CFM) MAX ESP (IN) MOTOR (HP) HEATING EXTRA HIGH (%) COOLING EXTRA HIGH (%) MAX OPERATING CURRENT (AMPS) MAX POWER CONSUMPTION (W) VOLTAGE PHASE (V/O) EXTRA HIGH AIRFLOW HIGH LOW ERV -101 - MITSUBISHI / LGH-F600RX3-E 100 600 0.8 0.75 69 44 39 37 30 2.9 654 208/3 48x45x16 160 1 ERV -102 - MITSUBISHI / LGH-F600RX3-E 100 600 0.8 0.75 69 44 39 37 30 2.9 654 208/3 48x45x16 160 1 ERV -103 - MITSUBISHI / LGH-F600RX3-E 100 600 0.8 0.75 69 44 39 37 30 2.9 654 208/3 48x45x16 160 1 ERV -104 - MITSUBISHI / LGH-F600RX3-E 100 600 0.8 0.75 69 44 39 37 30 2.9 654 208/3 48x45x16 160 1 ERV -105 - MITSUBISHI / LGH-F600RX3-E 100 600 0.8 0.75 69 44 39 37 30 2.9 654 208/3 48x45x16 160 1 ERV -201 - MITSUBISHI / LGH-F600RX3-E 100 600 0.8 0.75 69 44 39 37 30 2.9 654 208/3 48x45x16 160 1 ERV -202 - MITSUBISHI / LGH-F600RX3-E 100 600 0.8 0.75 69 44 39 37 30 2.9 654 208/3 48x45x16 160 1 ERV -203 - MITSUBISHI / LGH-F600RX3-E 100 600 0.8 0.75 69 44 39 37 30 2.9 654 208/3 48x45x16 160 1 ERV -204 - MITSUBISHI / LGH-F600RX3-E 100 600 0.8 0.75 69 44 39 37 30 2.9 654 208/3 48x45x16 160 1 ERV -205 - MITSUBISHI / LGH-F600RX3-E 100 600 0.8 0.75 69 44 39 37 30 2.9 654 208/3 48x45x16 160 1 ZN M d to to NOTES: 1) PROVIDE WITH PZ-52SF-E M -NET LOSSNAY CONTROLLER. ELECTRIC WATER HEATER SCHEDULE TAG AREA SERVED LOCATION MANUFACTURER / MODEL FAN MOTOR DIMENSIONS (DIAxHT) (INAN) TAG LOCATION MANUFACTURER / MODEL CAPACITY GAL) RECOVERY AT 60°F (GPH) TEMP SETTING (F CAPACITY KW CW INLET IN HW OUTLET IN ELECTRICAL 210 DIMENSIONS (DIAxHT) (INAN) OPERATING WEIGHT (LBS NOTES FLA AMPS VOLTAGE/PHASE V/0) EWH-1 KITCHEN BRADFORD WHITE / E32 -50S-3 50 42 120 6 1-1/4" 1-1/4" 50 208/3 22x47 650 1,2 GARAGE GREENHECK / SBE -21-36-10 13875 0.125 1 120/1 44x44x21 115 - GF -2 GARAGE GARAGE GREENHECK / SE1-12-426 925 NOTES: 1) PROVIDE WITH HEAT TRAPS ON SUPPLY AND DISCHARGE LINES. 1/10 120/1 18x18x11 20 - GF -3 GARAGE EXHAUST FAN SCHEDULE TAG AREA SERVED LOCATION MANUFACTURER / MODEL FAN MOTOR DIMENSIONS (DIAxHT) (INAN) WEIGHT (LBS NOTES FLOW CFM ESP IN WC POWER HP VOLTAGE/PHASE V/fti) EF -2 LOCKER ROOMS / GYM ROOF GREENHECK / G-065-VG/6/A 210 0.225 1/6 120/1 19x13 15 - O O CV Li) - U LL _ GF -1 GARAGE GARAGE GREENHECK / SBE -21-36-10 13875 0.125 1 120/1 44x44x21 115 - GF -2 GARAGE GARAGE GREENHECK / SE1-12-426 925 0.125 1/10 120/1 18x18x11 20 - GF -3 GARAGE GARAGE GREENHECK / SE1-18-436-133 2600 0.25 1/3 120/1 24x24x18 115 1 GF -4 GARAGE GARAGE GREENHECK / SE1-18-436-133 2600 0.25 1/3 120/1 24x24x18 115 1 F- cn NOTES: 1) CONTROLLED BY C4SENSORS. aid n�vz seers E o- REVIEWED FOR SDE COMPLIANCE APPROVED J. DEC 0 6 2016 City of Tukwila BUILDING DIVISION RECE1VE0. CITY OF `I't KWILA NUV 212016 PERN11IT CENTER JACKSON I MAIN ARCHITECTURE 311 FIRST AVENUE SOUTH SEATTLE, WA 98104 t 206.324.4800 WWW.JACKSONMAIN.COM v 0 J co co rbc. 0 "t w z (D) < Q)w� �U 1-- � co 00 = J z w O� U) U) Q O < ry O O CV Li) - v Z Z m 0 0 W 1-- � co 00 U® C) z w co U) Q = < ry LLI O - U LL _ U) Z LL O 0 o Lo E- Z 0 F - IL U U W � W F- cn Z W W U) J Q 0 W O W W U W W Q cc W 0 I= Q U) 0 W 0 0 = o U) o U O W O W W fA to 01LOICLICLI ZN M d to to co CD CD co CD (fl W O O O O O O F- d N w N �- N CD N N N m (� 00 00e - O �� 40503 SIONAL PROJECT NO.: 16025 PROJECT MGR.: SM DRAWN BY: BD CHECKED BY: SM MECHANICAL SCHEDULES � � F JACKSON I MAIN ARCHITECTURE P.S. © 2016 ;TUBE E SOUTH 98104 300 1AIN.COM SUITE 100 98057 ?822 g.com J CID � 00W z Q WS UQ � J O� U) O O N Lo n rn 0 of 0 0 0 N -a. N 8 1RE P.S. © 2016 '.._ z J m 00 reoco LL! F- FW- 00 �p zco U® w = < U) Q �LIJ zQ — U o o-0 U) Ll- o� O � �- n rn 0 of 0 0 0 N -a. N 8 1RE P.S. © 2016 Ari ----- i 16025 PROJECT MGR.: SM D_ .......... . ....___ CHECKED BY: SM z r 0 0 0 N Nr N co 67( n AG NOTES: > GARAGE EXHAUST FAN SHALL RUN CONTINUOUSLY. > GARAGE EXHAUST FAN SHALL RUN INTERMITTENTLY UPON CO SENSOR READING GREATER THAN 50 PPM. MINIMUM RUN TIME SHALL BE FIVE MINUTES. > GARAGE FAN SHALL RUN INTERMITTENTLY UPON CO SENSOR READING GREATER THAN 50 PPM. MINIMUM RUN TIME SHALL BE FIVE MINUTES. > PROVIDE CO SENSOR ON CEILING IN THIS APPROXIMATE. LOCATIONjo(M N015 5,, 1,, > PROVIDE CARBON MONOXIDE MONITERING SYSTEM TO INTERLOCK CO SENSORS WITH GARAGE FANS. ROUTE 6" SD BELOW GRADE AT 1 /8" PER FOOT SLOPE. iota—/L(G tia REVIEWED FOR CODE COMPLIANCE APPROVED DEC 0 6 2016 City of Tukwila [BUILDING DIVISION METRIX E N G I N E E It S 725 Powell Ave SW, SUITE 100 RENTON, WA 98057 425-336-2822 www.metrixeng.com z 16025 PROJECT MGR.: SM O BD CHECKED BY: SM z 0 �Z m Da �co W � CO cp Up a zco w �Q UQ ND 0_ U Q it (.) O J 0— 11 U z LL O O N Z) NLn �- z 16025 PROJECT MGR.: SM DRAWN BY: BD CHECKED BY: SM 0 a it U U W F- LU F- U) W U Z c/) U) d (n J Q p W U j W W U W W Q�o�Qcn W Q� �0Zpl-1- Wa0(-) = o � oOf ct� U o W o w W U CO 0 1 LO I a I (L Z N M �f to (A CO (0 CO CO Co (0 W o 0 0 0 0 CD H Q N 0 N r N (\0 N N N CO I- 00 CO �- r r PROJECT NO.: 16025 PROJECT MGR.: SM DRAWN BY: BD CHECKED BY: SM GARAGE HVAC PLAN I toil ' JACKSON I MAIN ARCHITECTURE P.S. © 2016 1 1T a rn 0 0) 0 Co r - C) N N 00 0 O t' , �z I i i vw� LUQ �4U) i I i i I i i i I I I I i i i I i i I I I— �� , 1 1T a rn 0 0) 0 Co r - C) N N 00 12"O-OA-UP 12"0 EA UP FLAG NOTES: 1�1--> EXISTING SUPPLY & RETURN GRILLES TO BE REPLACED WHERE HATCHED IN CORRIDOR. REVIEWED FOR CODE COMPLIANCE APPROVED DEC 0 6 2016 City,' of Tukwiia BUILDING DIVISION JACKSON I MAIN ARCHITECTURE 311 FIRST AVENUE SOUTH SEATTLE, WA 98104 t 206.324.4800 WWW.JACKSONMAIN.COM 0 O t' , �z I i i 12"O-OA-UP 12"0 EA UP FLAG NOTES: 1�1--> EXISTING SUPPLY & RETURN GRILLES TO BE REPLACED WHERE HATCHED IN CORRIDOR. REVIEWED FOR CODE COMPLIANCE APPROVED DEC 0 6 2016 City,' of Tukwiia BUILDING DIVISION JACKSON I MAIN ARCHITECTURE 311 FIRST AVENUE SOUTH SEATTLE, WA 98104 t 206.324.4800 WWW.JACKSONMAIN.COM z 0 ry CO co �z LIJ co cy) Q vw� LUQ �4U) 0 I I— �� � — �•_, Z J m O� U pO �00 W�— �p 0 W N L0 C) z O z 0 o �•_, Z J m pO �00 W�— �p W 00 C) p z00 w U) Q z OC w z Q _ U OLL -� z "N O 0 CL � U 0 F- a U CO W in W LLI F- LL U) Z s2�aU J a 0 w W w w U U w w w Q�o�G'1v� Q �pZ0F-F- W00L) 2�tn�Ir� U o W o w w cncootoaa Z , N M d to to CO CO CO (D Cfl W 0 0 0 0 0 0 F—N Q co N r N N N N c- LLr co C" 71 0 a; 0 co T O N N OD B A. A'....__—.__._.� ..__.. S. CONF 262 104 Sr- i i `I I f 12" 0 O -D NTO ERV 1-5 12"0 EA DN TO ERV 1-5 FLAG NOTES: EXISTING SUPPLY & RETURN GRILLES TO BE REPLACED WHERE HATCHED IN CORRIDOR. REVIEWED FOR CODE COMPLIANCE APPROV8� DEC 0 6 2616 City of Tukwila BUILDING DIVISION CITY OF TUP� I -A NUV 212016 PERPAIT CENTER JACKSON I MAIN ARCHITECTURE 311 FIRST AVENUE SOUTH SEATTLE, WA 98104 t 206.324.4800 WWW.JACKSONMAIN.COM z 0 z 0 Q z J m d O F- Uj �a �— H co U0 zco w U)Z) �( _ r�ZQ _U o� CI) z LL o 0 N "Ln i -- z 0 F- a U U W F- W Z W Z W�W U) S2 U Fl U) < D W W W W U W W W G7 Q� Q 0 m U �pZpl_ F- LU OC9(-) = o U -8 U O W p W W cncootoaa Z , N M ''t to to co co co to co co W O O O O O O N N N N N QN 00 r (O V` 0)O .- N ' itltiL I f Y Ilpq f` _ JACKSON I MAIN ARCHITECTURE P.S. 0 2016 ATE 100 )57 m 2 00 00 T - co m Q Q co co V - co m Q Q J_ Z) i - I 16025 SM BD SM a rn 0 0 o 0 N d' N P.S. © 2016 GENERAL NOTES: 1. COORDINATE LOCATION OF NEW FIRE SPRINKLER STANDPIPE FROM CIVIL DRAWINGS. FLAG NOTES: 1� EXPANSION AREA OF WORK. PROVIDE NEW FIRE SPRINKLER COVERAGE IN THIS AREA FROM NEW FIRE SPRINKLER SERVICE. EXISTING FLOOR PLAN WITH EXISTING FIRE SPRINKLER PIPING TO REMAIN. G ! EXISTING FIRE SPRINKLER SERVICE LOCATED IN THIS ROOM. a : i � i I i .._-.... STORAGE O 1-3 100 SF !; �'. 173 SF ! <3 I : 97 SF I STOAGESO�GE !I S O GE\\:2'�STORAGE \- \010 017 \I {y�� /�; fin} 140 SF 87 SF Ei 87 SF ,I 108 SF � rQRAGEN\11 11, s 021 I 11 108 SF STORAGE S 1 ORAGE STO GE \' 022:'' 023 ' i 024 �\ 107 SF 107 SF \ ' 108 SF N { I STORAGE X02:\ �108SF, STORAGE \ 026 \104SFN REVIEWED FOR CODE COMPLIANCE APPROVED DEC 0 6 2016 City of Tukwila BUILDING DIVISION _ `� R�.ClE1!/ FD CITY Y OF UMAL.A NUV 212016 PERMIT CENTER FAETRIX E N G I N E E R S 725 Powell Ave SW, SUITE 100 RENTON, WA 98057 425-336-2822 www.metrixeng.com z O x .Qmcc) �W00 z ma Q `ME= (bWS Z m tac3 U cr— 00 = Q � CO 0 zco W O� u)::) o I— :D O _v N OJ LO I I z O z O D Z m cr— 00 W�— �p � CO 0 zco W � W :D _v OJ n— I I U U. O N � u7 I— Z O U U) WF- ❑ W LLI FW ; WSW J Q UW cn w a cn w p W W U W W Q�❑�C�cn WIll Q �❑Z❑f—I— W ❑ 0 0 U W W W C> C) u�❑�a ZN ch -'t LO Lf) (0cocoCD(0� W ���--� O O O o o I- N N r N C N N N ❑ T ti CO O r r h 7 JACKSON I MAIN ARCHITECTURE P.S. © 2016 0 N 0 0 0 N N :NERAL NOTES: ;OORDINATE LOCATION OF NEW FIRE SPRINKLER STANDPIPE =ROM CIVIL DRAWINGS. AG NOTES: > EXPANSION AREA OF WORK. PROVIDE NEW FIRE SPRINKLER COVERAGE IN THIS AREA FROM NEW FIRE SPRINKLER SERVICE. > EXISTING FLOOR PLAN WITH EXISTING FIRE SPRINKLER PIPING TO REMAIN. > EXISTING FLOOR PLAN WITH EXISTING FIRE SPRINKLER SERVICE TO REMAIN. VERIFY SPRINKLER COVERAGE REMAINS COMPLIANT WITH ANY FLOOR PLAN OR FURNITURE REVISION. > EXISTING SPRINKLER HEADS TO BE REPLACED WHERE HATCHED IN CORRIDOR. REVIEWED FOR ODE COMPLIANCE APPROVED DEC 0 6 2016 11. Citj of Tuk-,.v*la BUILDING DIVISION RECEIVED CITY OF T U KWILA NOV 212016 PER -BAIT CENTER JACKSON I MAIN ARCHITECTURE 311 FIRST AVENUE SOUTH SEATTLE, WA 98104 t 206.324.4800 WWW.JACKSONMAIN.COM Z z m -j CO wI-�- t]'- u co �r p �y co UQ two =� LIM w Q — �? z w LL� O 0 N =)-E F- F - U 0 O i U O F- C) N LO Z z m ry O wI-�- t]'- u co 00 �r p z w co UQ =� D L w Q — („) O LL� O 0 N =)-E L F - Z O F- CL U W 1- W F- U) I- W U) Z U) n U) J p W O W W U W W W Q Q � a w 0 C) W 0 (9 2-fn8 U 0 W p W W cn c0 O LO a EL z— N M d' L0 to GO co co CO (fl 10 W 0 00 0 0 1- N N N N N N Q 0 r (co \ r N `- I*- CO W T p 4 =3 q 4� AL PROJECT NO.: 16025 PROJECT MGR.: SM DRAWN BY: BD CHECKED BY: SM FIRST FLOOR FIRE SPRINKLER PLAN e JACKSON I MAIN ARCHITECTURE P.S. @2016 .. - -- - - --- - I All a co GENERAL NOTES: 1. COORDINATE LOCATION OF NEW FIRE SPRINKLER STANDPIPE FROM CIVIL DRAWINGS. FLAG NOTES: E:�> EXPANSION AREA OF WORK. PROVIDE NEW FIRE SPRINKLER COVERAGE IN THIS AREA FROM NEW FIRE SPRINKLER SERVICE. [2�> EXISTING FLOOR PLAN WITH EXISTING FIRE SPRINKLER PIPING TO REMAIN. EXISTING FLOOR PLAN WITH EXISTING FIRE SPRINKLER SERVICE TO REMAIN. VERIFY SPRINKLER COVERAGE REMAINS COMPLIANT WITH ANY FLOOR PLAN OR FURNITURE REVISION. [4�> EXISTING SPRINKLER HEADS TO BE REPLACED WHERE HATCHED IN CORRIDOR. 1 REVIEWED FOR CODE COMPLIANCE APPROVED DEC 0 6 2016 City of Tukwila BUILDING DIVISION CITY OF TUKWIL f NUV 21 2016 ;y PEMMIT CENTER z J co O W vW� z J F ® i ®oma LuLLITZ r1yo_ CN Lo z O z O i- z ®oma LuLLITZ r1yo_ � TZ U 0 z 00W a UQ �W :� OJ ©— C/) — U 0o z o o - Immommom U Z O a U U W F- LU LU F- U) ZUJ W Z W W U J c)aU) owWwwg U W W W Q Qir00 Ja ) ❑Z❑hF- W ❑C9U :E 2-0(n 0� cr- U p W p W W z�- N M It Lo Lo co co co co to C° W 0 0 0 0 0 0 F- N N N N N N O r Co (o ❑ -dN O LL 40503 S'`ONAL 'L 6 PROJECT NO.: 16025 PROJECT MGR.: SM DRAWN BY: BD CHECKED BY: SM SECOND FLOOR FIRE SPRINKLER PLAN JACKSON I MAIN ARCHITECTURE P.S. 0 2016