HomeMy WebLinkAboutPermit M16-0178 - 18370 OLYMPIC BUILDING / VACANT SPACE - RESTROOM EXHAUST FANS, GRILLES, DIFFUSERS AND DUCTWORKVACANT SPACE 18370 OLYMPIC AVE S M16-0178 City of Tukwila • Department of Community Development • 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Inspection Request Line: 206-438-9350 Web site: http://www.TukwilaWA.Rov MECHANICAL PERMIT Parcel No: 7888900153 Permit Number: M16-0178 Address: 18370 OLYMPIC AVE S BLDG Issue Date: 12/13/2016 Permit Expires On: 6/11/2017 Project Name: VACANT SPACE Owner: Name: TERRENO OLYMPIC LLC Address: 101 MONTGOMERY ST STE 200, SAN FRANCISCO, WA, 94105 Contact Person: Name: WILLIAM MILLHOLLIN Address: 9808 31ST AVE SE, EVERETT, WA, International Residential Code Edition: 98208 Contractor: 2014 Name: MECHANICAL & CONTROL SERVICES WAC 296-466: INC Address: 6426 18TH ST E, FIFE, WA, 98424 License No: MECHACS962BT Lender: 2015 Name: Phone: (206) 601-7043 Phone: (253) 926-9777 Expiration Date: 2/26/2018 Address: , , , DESCRIPTION OF WORK: INSTALL (2) BATHROOM EXHAUST FANS WITH NEW DIRECT VENT, 5 NEW GRILLES & 6 NEW DIFFUSERS WITH ASSOCIATED DUCTWORK UTILIZING EXISTING PENETRATIONS CONNECTED TO EXISTING RTU HVAC. Valuation of Work: $9,000.00 Fees Collected: $311.22 Type of Work: REPLACEMENT Electrical Service Provided by: PUGEST SOUND ENERGY Fuel type: ELECT Water District: TUKWILA Sewer District: TUKWILA Current Codes adopted by the City of Tukwila: International Building Code Edition: 2015 National Electrical Code: 2014 International Residential Code Edition: 2015 WA Cities Electrical Code: 2014 International Mechanical Code Edition: 2015 WAC 296-466: 2014 Uniform Plumbing Code Edition: 2015 WA State Energy Code: 2015 International Fuel Gas Code: 2015 vt�JPermit Date: �� �� Center Authorized Signature: I hearby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this development permit and agree to the conditions attached to this permit. Signa Print Date: 12.1!3/ (L This permit shall become null and void if the work is not commenced within 180 days for the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. PERMIT CONDITIONS: 1: All construction shall be done in conformance with the Washington State Building Code and the Washington State Energy Code. 2: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. 3: `MECHANICAL PERMIT CONDITIONS' 4: All mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center (206/431-3670). 5: All permits, inspection record card and approved construction documents shall be kept at the site of work and shall be open to inspection by the Building Inspector until final inspection approval is granted. PERMIT INSPECTIONS REQUIRED Permit Inspection Line: (206) 438-9350 1800 MECHANICAL FINAL 0701 ROUGH -IN MECHANICAL CITY OF TUKWILA Community Development Department Permit Center • 6300 Southcenter Blvd., Suite 100 Tulovila, WA 98188 [ittp://www.Tukwi]aWA.go_v SITE LOCATION Mechanical Permit No. Project No. Date Application Accepted: Date Application Expires:'��! use MECHANICAL PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. **please print** King Co Assessor's Tax No.: 7888900153 Site Address: 18370 OLYMPIC AVE S Suite Number: Floor: I Tenant Name: (Vacant) New Tenant: ❑ .....Yes ®..No PROPERTY OWNER Name: TERRENO OLYMPIC LLC Address: 18370 OLYMPIC AVE S City: Tukwila State: WA Zip: 98188 CONTACT PERSON — person receiving all project communication Name: William Millhollin Address: 9808 31 st Ave SE City: Everett State: WA zip: 98208 Phone: (206) 601-7043 Fax: Email: william@nwpermit.com Valuation of project (contractor's bid price): $ 9,000 Describe the scope of work in detail: MECHANICAL CONTRACTOR INFORMATION Company Name: Mechanical and Control Services Address: 6426 18th St E City: Fife State: WA Zip: 98424 Phone: (253) 926-9777 Fax: Contr Reg No.: MECHACS962BT Exp Date: 02/26/2018 Tukwila Business License No.: 238220 Install 2 bathroom exhaust fans with new direct vent, 5 new grills & 6 new diffusers with associated ductwork utilizing existing penetrations connected to existing RTU HVAC. Use: Residential: New .......... ❑ Replacement ........ ❑ Commercial: New .......... ❑ Replacement ........ m Fuel Type: Electric..... m Gas ....... ❑ Other: H:WpplicationsTorris-Applications On Line\20I6 ApplirationsNechanical Perrnit Application Revised 14.16.docx Revised: January 2016 Pagel of 2 bh Indicate type of mechanical work being installed and the quantity below: Unit Type Qty Furnace <100k btu Residential, Nighttime Furnace >100k btu 11 Floor furnace 2 Suspended/wall/floor mounted heater 57 dB(A) Appliance vent Commercial Repair or addition to heat/refrig/cooling system 47 dB(A) Air handling unit <10,000 cfm 65 dB(A) Unit Type Qty Air handling unit >I0.000 cfim Residential, Nighttime Evaporator cooler 11 Ventilation fan connected to single duct 2 Ventilation system 57 dB(A) Hood and duct Commercial Incinerator — domestic 47 dB(A) Incinerator — comm/industrial 65 dB(A) Unit Type Qty Fire damper Residential, Nighttime Diffuser 11 Thermostat 55 dB(A) Wood/gas stove 57 dB(A) Emergency enerator Commercial Other mechanical equipment 47 dB(A) 60 dB(A) 65 dB(A) Boiler/Compressor Qty 0-3 hp/100,000 btu 3-15 h /500.000 btu 15-30 hp/1,000,000 btu 30-50 hp/1,750,000 btu 50+ h /1.750.000 btu Noise: Mechanical units need to be in compliance with the Tukwila Noise Code. Maximum permissible sound levels are based on from where the sound is created and where the sound is heard. Additionally, if sound can be heard from within a house at night in a residential zone it may not be allowed. For more details. see TMC 8.22 District of Sound Producing Source District of Receiving Property Residential, Daytime* Residential, Nighttime Commercial Industrial Residential 55 dB(A) 45 dB(A) 57 dB(A) 60 dB(A) Commercial 57 dB(A) 47 dB(A) 60 dB(A) 65 dB(A) Industrial 60 dB(A) 50 dB(A) 65 dB(A) 70 dB(A) *Daytime means 7AM-1 OPM, Monday through Friday and 8AM-IOPM, Saturday, Sunday and State -recognized holidays. A few sounds are exempt from the noise code, including: Warning devices-, Construction and property maintenance during the daytime hours (lam -1 Opm), Testing of backup generators during the day. PERMIT APPLICATION NOTES - Value of construction — in all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the permit center to comply with current fee schedules. Expiration of plan review — applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The building official may grant one extension of time for additional periods not to exceed 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING O/WNER OR AUTHORIZED AGENT: Signature: / Date: 11/08/2016 Print Name: William Millhollin Mailing Address: 9808 31 st Ave SE Day Telephone: (206) 601-7043 Everett WA 98208 City State Zip HAApplicationsTorms-Applicat ions On Line12016 ApplicationsWechanical Permit Application Revised 1-4-16.docx Revised: January 2016 Page 2 of 2 bh DESCRIPTIONS / PermitTRAK $251.37 M16-0178 Address: 18370 OLYMPIC AVE S BLDG Apn: 7888900153 $251.37 MECHANICAL $239.40 PERMIT ISSUANCE BASE FEE R000.322.100.00.00 0.00 $32.50 PERMIT FEE R000.322.100.00.00 0.00 $206.90 TECHNOLOGY FEE $11.97 TECHNOLOGY FEE TOTAL FEES 1R10023 R000.322.900.04.00 0.00 $11.97 $251.37 Date Paid: Tuesday, December 13, 2016 Paid By: NORTHWEST PERMIT INC Pay Method: CHECK 10457 Printed: Tuesday, December 13, 2016 11:42 AM 1 of 1 SYSTEMS Date Paid: Tuesday, November 29, 2016 Paid By: NORTHWEST PERMIT INC Pay Method: CHECK 10455 Printed: Tuesday, November 29, 2016 2:33 PM 1 of 1 RWY57EM5 INSPEi Retain a IN ION NO. :TION RECORD copy with permit '-GIS PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Project: &AAJT ACS' Type of Inspection: A/ 'W L Address: V0 0 ol'ywum G Date Called: ecial Instructions: Date Wand: a.m. lO % 'l m. [Reques,fer: Phone No: Approved per applicable codes. E Corrections required prior to approval. I paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Project: e" Type of Inspection: . A✓d Address: /93 70 OL -2M AvE 5 Date Called: - Special Instructions:rRequestef: ate Wante '7 � m. Phone No: Approved per applicable codes. U Corrections required prior to approval. U paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. BR4G!1,rkN` FILE SPECIFICATION SHEET QTR / OTRE SERIES FANS n QTR080 QTR110 MODELS QTR050F, QTR080, QTR110, QTRE080, QTRE080R, QTRE110 QTRE08OR QTRE080 IIQ Ultra -quiet, high performance bath fan with a modern -styled grille. FEATURES BLOWER: • Plug-in, permanently lubricated motor - engineered for continuous operation • Dynamically balanced centrifugal blower wheel for quiet, efficient performance • Low RPM for quiet operation • Resilient anti -vibration motor mounts (QTR080 only) HOUSING: • Rugged, 26 gauge, galvanized steel construction • Polymeric, 4" round duct connector with tapered sleeve and no metallic clatter • 7-5/8" height allows for 2" x 8" (nominal) joist installations • Sturdy, easy mounting directly to joist • Includes hanger bars to position housing anywhere between 16" to 24" -on -center joists (Models QTRE080 & QTRE110 only) • Includes mounting frame for easy retrofit or replacement of existing fan (QTRE808R only) GRILLE: • Polymeric construction • Innovative design - the result of extensive research with designers and consumers BUILDER PACKS: • Broan Model QTRO50F - Includes blower and grille only (packed 1 per carton) • Rough -in housing required - order Broan Model QTXROOOHF (4 housings per carton) Includes hanger bars to position housing anywhere between 16" to 24" -on -center joists (4 sets of hangers per carton) Two sets of mounting holes for hanger bars allow flush installation with bottom or top of drywall CONTROLS (Purchase separately): • Model 69VL (Ivory) / 69WL (White) -One rocker switch with "on" indicator light • Other controls available from Broan-NuTone U.L. Listed for use over bathtubs and showers when connected to a GFCI protected branch circuit (ceiling mount only). 3 -Year Warranty Broan-N REFERENCE QTY. RECEIVED CI7Y OF TUKWIL NOV 2 9 2016 PERMIT CENTF14 TYPICAL SPECIFICATION Ceiling Ventilator shall be Broan Model OTRO50F (QTRO80) (QTR110) (QTRE080) (QTRE080R)(QTRE110). Ceiling Ventilator shall have corrosion resistant galvanized steel housing. It shall be ducted to a roof or wall cap using 4" round ductwork. Blower assembly shall be removable, have a centrifugal -type blower wheel and a permanently lubricated motor designed for continuous operation. Non-metallic damper/duct connector shall be included. Air delivery shall be no less than 50 (80) (110) CFM and sound level no greater than 0.4 (0.8) (1.0) (1.3) (1.5) Sones. All air and sound ratings shall be certified by HVI. Ceiling ventilator shall be Energy Star® qualified and have an energy efficient permanent split capacitor motor (Models QTRE080, QTRE08OR & QTRE110 only). Ceiling Ventilator shall be U.L. Listed for use over bathtubs and showers when connected to a GFCI protected branch circuit. ® ' ' n- HVI CERTIFIED DEC 0 6 2M City of Tukwila BUILDING DIVISION QTR110 1�s 8 i r IOi IIs 2 J. QTRE080R I 13 14 )an.com 800-558-1711 Project Location Architect Engineer Contractor Submitted by QTRE110 r Models QTRE080, QTRE080R & QTRE110 only Date 0118 21J 99043401H 'J PERFORMANCE RATINGS QTR / QTRE SERIES FANS HVI PERFORMANCE Model Static Pressure (Ps) CFM Sones Fan Watts QTRO50F 0.10 50 0.4 0.3 0.25 28 0.3 QTRO80 0.10 80 1.0 0.25 66 QTR110 0.10 110 1.5 0.25 98 QTRE080 OTRE08OR 0.10 80 0.8 28.2 0.25 55 QTRE110 0.10 110 1.3 36.3 0.25 90 ® HVI-2100 CERTIFIED RATINGS comply with new testing technologies and procedures prescribed by the Home N V' Ventilating Institute, for off-the-shelf products, as they are available to consumers. Product performance is rated at 0.1 in. static pressure, based on tests conducted in a state-of-the-art CERTIFIED test laboratory. Sones are a measure of humanly -perceived loudness, based on laboratory measurements. AMPS I WEIGHT Model Amps QTR050F 0.2 QTR080 0.7 QTR110 0.3 QTRE080 QTRE080R 0.3 QTRE110 0.3 Model Shipping Weight QTRO50F 6.6 lbs. QTRO80 12.4 lbs. QTR110 1 12.4 lbs. QTRE080 QTRE08OR 12.4 lbs. QTRE110 13.0 lbs Models QTRE080, QTRE080R & QTRE110 only AIR FLOW PERFORMANCE MODEL OTRO50F 0.5 0.4 0.3 3 C 0.2 a 0.1 0.0 0.5 0.4 3 0.3 a 0.2 0.1 0.0 0 10 20 30 40 50 60 70 80 90 100 Airflow (cfm) MODEL OTRE110 0.7 0.s 0.5 0.1 0 10 20 30 40 50 60 70 0.0 Airflow (cfm) 0 10 20 30 40 50 60 70 80 90 100 110 120 130 BR`� IV` Airflow (cfm) V. Broan-NuTone LLC Hartford, Wisconsin www.broan.com 800-558-1711 BR4S4rkN` SPECIFICATION SHEET QTR QTRE SERIES FANS QTR110 MODELS QTR050F, QTR080, QTR110, QTRE080, QTRE080R, QTRE110 QTRE080R QTRE080 110 Ultra -quiet, high performance bath fan with a modern -styled grille. FEATURES BLOWER: • Plug-in, permanently lubricated motor - engineered for continuous operation • Dynamically balanced centrifugal blower wheel for quiet, efficient performance • Low RPM for quiet operation • Resilient anti -vibration motor mounts (QTR080 only) HOUSING: • Rugged, 26 gauge, galvanized steel construction • Polymeric, 4" round duct connector with tapered sleeve and no metallic clatter • 7-5/8" height allows for 2" x 8" (nominal) joist installations • Sturdy, easy mounting directly to joist • Includes hanger bars to position housing anywhere between 16" to 24" -on -center joists (Models QTRE080 & QTRE110 only) • Includes mounting frame for easy retrofit or replacement of existing fan (QTRE808R only) GRILLE: • Polymeric construction • Innovative design - the result of extensive research with designers and consumers BUILDER PACKS: • Broan Model QTR050F - Includes blower and grille only (packed 1 per carton) • Rough -in housing required - order Broan Model QTXROOOHF (4 housings per carton) Includes hanger bars to position housing anywhere between 16" to 24" -on -center joists (4 sets of hangers per carton) Two sets of mounting holes for hanger bars allow flush installation with bottom or top of drywall CONTROLS (Purchase separately): • Model 69VL (Ivory) / 69WL (White) -One rocker switch with "on" indicator light • Other controls available from Broan-NuTone U.L. Listed for use over bathtubs and showers when connected to a GFCI protected branch circuit (ceiling mount only). 3 -Year Warranty TYPICAL SPECIFICATION Ceiling Ventilator shall be Broan Model QTR050F (QTR080) (QTR110) (QTRE080) (QTRE080R)(QTRE110). Ceiling Ventilator shall have corrosion resistant galvanized steel housing. It shall be ducted to a roof or wall cap using 4" round ductwork. Blower assembly shall be removable, have a centrifugal -type blower wheel and a permanently lubricated motor designed for continuous operation. Non-metallic damper/duct connector shall be included. Air delivery shall be no less than 50 (80) (110) CFM and sound level no greater than 0.4 (0.8) (1.0) (1.3) (1.5) Sones. All air and sound ratings shall be certified by HVI. Ceiling ventilator shall be Energy Star® qualified and have an energy efficient permanent split capacitormotor (Models QTRE080, OTRE08OR & QTRE110only). Ceiling Ventilator shall be U.L. Listed for use over bathtubs and showers when connected to a GFCI protected branch circuit. Broan-NuTone LLC Hartford, Wisconsin www.broan.com 800-558-1711 QTRE110 Models QTRE080, QTRE08OR & QTRE110 only I REFERENCE I QTY. I REMARKS I Proiect I Location Architect Engineer Contractor Submitted by Date 21J 99043401H 1's I8 IOi 2 v ® , QTRE08OR s_ I > CH�V 13. IA Broan-NuTone LLC Hartford, Wisconsin www.broan.com 800-558-1711 QTRE110 Models QTRE080, QTRE08OR & QTRE110 only I REFERENCE I QTY. I REMARKS I Proiect I Location Architect Engineer Contractor Submitted by Date 21J 99043401H ' 4 PERFORMANCE RATINGS QTR / QTRE SERIES FANS HVI PERFORMANCE Model Static Pressure (Ps) CFM Sones Fan Watts QTRO50F 0.10 50 0.4 0.3 0.25 28 0.3 QTRO80 0.10 80 1.0 0.25 66 QTR110 0.10 110 1.5 0.25 98 QTRE080 OTRE08OR 0.10 80 0.8 28.2 0.25 55 QTRE110 0.10 110 1.3 36.3 0.25 90 ® HVI-2100 CERTIFIED RATINGS comply with new testing technologies and procedures prescribed by the Home N V' Ventilating Institute, for off-the-shelf products, as they are available to consumers. Product performance is rated at 0.1 in. static pressure, based on tests conducted in a state-of-the-art CERTIFIED test laboratory. Sones are a measure of humanly -perceived loudness, based on laboratory measurements. AMPS Model Amps QTR050F 0.2 QTRO80 0.7 QTR110 0.3 QTRE080 OTRE08OR 0.3 QTRE110 0.3 WEIGHT Model Shipping Weight QTR050F 6.6 lbs. QTR080 12.4 lbs. QTR110 12.4 lbs. QTRE080 OTRE08OR 12.4 lbs. QTRE110 13.0 lbs Models QTRE080, QTRE080R & QTRE110 only AIR FLOW PERFORMANCE MODEL OTRO50F 0.5 0.4 0'0.3 3 c 0.2 a 0.1 0.0 A - , - - , - =jqL#jd: 1 • 1 .:.................... ■■■■■■■■■■■■■■■■■■■■■■■■ .:O\■■■■■■■■■■■■■■■■■■■■■■ ■■\qM■■■■■■■■■■■■■■■■■■■ . ■■■■O\M■■■■■■■■■■■■■■■■■ ■■■■■■■MOMM■■■■■■■■■■■■■ . ■■■■■■■■■\O\■■■■■■■■■■■■ • - ■■■■■■■■■■■■MO\■■■■■■■■■ ■■■■■■■■■■■■■■■►■■■■■■■■ ■■■■■■■■■■■■■■■■O■■■■■■■ ■■■■■■■■■■■■■■■■■\■■■■■■ ■■■■■■■■■■■■■■■■■M ■■■■■ . ■■■■■■■■■■■■■■■■■■W■■■■■ ■■■■■■■■■■■■■■■■■■■►M■■■■ ■■■■■■■■■■■■■■■■■■■■M■■■ ■■■■■■■■■■■■■■■■■■■■��■■ ■■■■■■■■■■■■■■■■■■■■■\■■ ■■■■■■■■■■■■■■■■■■■■■■\■ ..■■■■■■■■■■■■■■■■■■■■■■�� • � !� 1 . 1 ! 1 . 1 - 0.5 0.4 CP 3 0.3 a 0.2 0.1 0.0 0 10 20 30 40 50 60 70 80 90 100 Airflow (cfm) MODEL OTRE110 0.7 0.6- 0.5 0 10 20 30 40 50 60 70 0.0 Airflow (cfm) 0 10 20 30 40 50 60 70 80 90 100 110 120130 Bl, Airflow (cfm) v. Broan-NuTone LLC Hartford, Wisconsin www.broan.com 800-558-1711 PERMIT COOK® COP I - PLAN REVIEW/ROUTING SLIP PERMIT NUMBER: M16-0178 PROJECT NAME: VACANT SPACE SITE ADDRESS: 18370 OLYMPIC AVE S DATE: 11/29/16 X Original Plan Submittal Revision # before Permit Issued Response to Correction Letter # Revision # DEPARTMENTS: 4E- Awc ►?-)A Building Division IP Public Works ❑ PRELIMINARY REVIEW: Not Applicable ❑ (no approval/review required) W 1 Fire Prevention Structural ❑ after Permit Issued Planning Division ❑ Permit Coordinator 4 DATE: 12/01/16 Structural Review Required ❑ REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: DUE DATE: 12/29/16 Approved ❑ Approved with Conditions Corrections Required ❑ Denied ❑ (corrections entered in Reviews) (ie: Zoning Issues) Notation: REVIEWER'S INITIALS: IRIAMa Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: 12/18/2013 MECHANICAL & CONTROL SRVCQ INC Page 1 of 3 Home Espanol Contact Search L&I A -Z, Index Help My f.,&t Safety & Health Claims & Insurance Workplace Rights Trades & Licensing Washington State Department of Labor & Industries MECHANICAL & CONTROL SRVCS INC Owner or tradesperson 642618th St E FIFE, WA 98424 Principals 253-926.9777 Hull, Travis Edward, PRESIDENT PIERCE County Hunt, Ted Lamond, VICE PRESIDENT HULL, ANGELA DAWN, SECRETARY GROVER, HAROLD, VICE PRESIDENT (End: 02/26/2010) DICKSON, PAUL, TREASURER (End: 02/26/2010) Doing business as MECHANICAL & CONTROL SRVCS INC WA UBI No. Business type 602 338 440 Corporation Governing persons ANGELA DAWN HULL TRAVIS EDWARD HULL; License Verify the contractor's active registration / license / certification (depending on trade) and any past violations. Construction Contractor Active. Meets current requirements. License specialties GENERAL License no. MECHACS962BT Effective — expiration 01/30/2004— 02/26/2018 Bond ................. American Contractors Indem CO $12,000.00 Bond account no. 100239439 Received by L&I Effective date 02/10/2014 02/06/2014 Expiration date Until Canceled Bond history Insurance ... ......................... Continental Western Ins Co $1,000,000.00 Policy no. 6023856626 Help us improve https://secure.Ini.wa.gov/verify/Detail.aspx?UBI=602338440&LIC=MECHACS962BT&SAW= 12/13/2016 A ni nn r A SMilXIIRPAML�1' Plan review ^,pproval is subject to errors and orn -sio o. Approval of consiruciian documents does nrit au Iron__ the violation of any adopted code or ordinance. Re slpt of approved f=ield Copy and conditions is acknoivlea d: By: Date. n City of Tul ila BUILDING DIVISION U hilachanical I -Electrical Plumbing was Piping � —tof Tukwila El' ` DIVEl01V SYMBOLS SUPPLY AIR DUCT RETURN AIR DUCT CEILING DIFFUSER RETURN GRILL EXHAUST FAN (DIRECT VENT) V' -r. © . REVISIONS No changes shall bo made to the scope Of work without prior approval of Tul(wila Building Division. NOTE: Fevisi and ons will require a new plan submittal may include additional plan review fees. GENERAL NOTES SITE INFO ADDRESS 18370 OLYMPIC AVE S Parcel 7888900153 Leaal Descriation SOUTHCENTER SOUTH INDUSTRIAL PARK LOT 18 OF TUKWILA AMENDED SHORT PLAT NO MF 78 -19 -SS RECORDING NO 7807210798 SD PLAT DAF - BEG SW COR LOT 16 PLAT OF SOUTHCENTER SOUTH INDUSTRIAL PARK TH N 78-36-10 W 360 FT TH N 11-23-50 E 698.25 FT TH ALG CURVE TO RGT RAD 110 FT ARC DIST 172.79 FT TH RU C/A 90-00-00 TH S 78-36-10 E 480 FT TH ALG CURVE TO RGT RAD 110 FT ARC DIST 172.79 FT THRU C/A 90-00-00 TH S 11-23-50 W 648.25 FT TH ALG CURVE TO LFT RAD 50 FT ARC DIST 78.54 FT THRU C/A 90-00-00 TH N 78-36-10 W TO POB DUCTWORK 1.1 ALL DUCT DIMENSIONS ON PLAN ARE CLEAR INSIDE DIMENSIONS, ADD 2" TO EACH DIMENSION TO OBTAIN OUTSIDE DIMENSION. ADD 4"TO EACH DIMENSION IF DUCTWORK IS ON THE EXTERIOR OF BUILDING. 1.2 THE FIRST NUMBER ON ALL DUCT DIMENSIONS IS THE WIDTH AND THE SECOND NUMBER IS THE HEIGHT. 1.3 MATERIALS WITHIN DUCTS OR PLENUMS SHALL HAVE A FLAME SPREAD RATING LESS THAN 25 AND A FLAME SMOKE DEVELOPMENT RATING LESS THAN 50, PER IMC 602.2.1. 1.4 SEAL ALL TRANSVERSE JOINTS FOR DUCTWORK WITH STATIC PRESSURE BETWEEN 1/2 INCHES AND 2 INCHES. DUCTWORK WHICH IS DESIGNED TO OPERATE AT PRESSURES ABOVE 1/2 INCH WATER COLUMN STATIC PRESSURE SHALL BE SEALED IN ACCORDANCE WITH STANDARD RS -7. 1.5 ALL DUCT GAUGES PER SMACNA, IMC 603-4. 1.6 ALL DUCT SUPPORTS PER SMACNA, IMC 603-10. 1.7 ATTACH DIFFUSERS AND GRILLES TO T -BAR GRID PER WA STATE & LOCAL CODES. 1.8 BALANCING DAMPERS ARE TO BE INSTALLED ON ALL BRANCH DUCTS OR DIFFUSERS. 1.7 Co de- F-cQ t t a v� : zo 1 S 1-1�L C, a Cv�Vrt.K S,te4 CN S REVIEWED FOR CODE COMPLIANCE APPROVED DEC 0 6 2016 IC City of Tukwila BUILDING DIVISION RECEIVED CITY OF TUKWILA► NOV 29 2016 PERMIT CENTER General Notes No. I Revision/Issue I Date [Firm Name and Address — CMECHANICAL & CCi1tiTTI L>SE'IA�tICES, la'�1C IS- 'P I I I M' i.' ~S 642618TH ST E Travis Hull FIFE, WA 98424 253-926-9777 Project Name and Address Olympic Building HVAC Redistribution 18370 OLYMPIC AVE S Tukwila, WA 98188 W Vietnamese catnolic_ ", Qc� Community o-® Wanke Cascade n 90 M MIE. f BO Design Imports India Q 17-Y 17-11 11'-1�' 17-f s x 8 Protime Sports c� OE RK ` y A , ] � 4 0 -M ^ 1$1 P 8 Sears Outlet Bralco Metals Cl? Y FFt E Zonar Systems, Inc g A ni nn r A SMilXIIRPAML�1' Plan review ^,pproval is subject to errors and orn -sio o. Approval of consiruciian documents does nrit au Iron__ the violation of any adopted code or ordinance. Re slpt of approved f=ield Copy and conditions is acknoivlea d: By: Date. n City of Tul ila BUILDING DIVISION U hilachanical I -Electrical Plumbing was Piping � —tof Tukwila El' ` DIVEl01V SYMBOLS SUPPLY AIR DUCT RETURN AIR DUCT CEILING DIFFUSER RETURN GRILL EXHAUST FAN (DIRECT VENT) V' -r. © . REVISIONS No changes shall bo made to the scope Of work without prior approval of Tul(wila Building Division. NOTE: Fevisi and ons will require a new plan submittal may include additional plan review fees. GENERAL NOTES SITE INFO ADDRESS 18370 OLYMPIC AVE S Parcel 7888900153 Leaal Descriation SOUTHCENTER SOUTH INDUSTRIAL PARK LOT 18 OF TUKWILA AMENDED SHORT PLAT NO MF 78 -19 -SS RECORDING NO 7807210798 SD PLAT DAF - BEG SW COR LOT 16 PLAT OF SOUTHCENTER SOUTH INDUSTRIAL PARK TH N 78-36-10 W 360 FT TH N 11-23-50 E 698.25 FT TH ALG CURVE TO RGT RAD 110 FT ARC DIST 172.79 FT TH RU C/A 90-00-00 TH S 78-36-10 E 480 FT TH ALG CURVE TO RGT RAD 110 FT ARC DIST 172.79 FT THRU C/A 90-00-00 TH S 11-23-50 W 648.25 FT TH ALG CURVE TO LFT RAD 50 FT ARC DIST 78.54 FT THRU C/A 90-00-00 TH N 78-36-10 W TO POB DUCTWORK 1.1 ALL DUCT DIMENSIONS ON PLAN ARE CLEAR INSIDE DIMENSIONS, ADD 2" TO EACH DIMENSION TO OBTAIN OUTSIDE DIMENSION. ADD 4"TO EACH DIMENSION IF DUCTWORK IS ON THE EXTERIOR OF BUILDING. 1.2 THE FIRST NUMBER ON ALL DUCT DIMENSIONS IS THE WIDTH AND THE SECOND NUMBER IS THE HEIGHT. 1.3 MATERIALS WITHIN DUCTS OR PLENUMS SHALL HAVE A FLAME SPREAD RATING LESS THAN 25 AND A FLAME SMOKE DEVELOPMENT RATING LESS THAN 50, PER IMC 602.2.1. 1.4 SEAL ALL TRANSVERSE JOINTS FOR DUCTWORK WITH STATIC PRESSURE BETWEEN 1/2 INCHES AND 2 INCHES. DUCTWORK WHICH IS DESIGNED TO OPERATE AT PRESSURES ABOVE 1/2 INCH WATER COLUMN STATIC PRESSURE SHALL BE SEALED IN ACCORDANCE WITH STANDARD RS -7. 1.5 ALL DUCT GAUGES PER SMACNA, IMC 603-4. 1.6 ALL DUCT SUPPORTS PER SMACNA, IMC 603-10. 1.7 ATTACH DIFFUSERS AND GRILLES TO T -BAR GRID PER WA STATE & LOCAL CODES. 1.8 BALANCING DAMPERS ARE TO BE INSTALLED ON ALL BRANCH DUCTS OR DIFFUSERS. 1.7 Co de- F-cQ t t a v� : zo 1 S 1-1�L C, a Cv�Vrt.K S,te4 CN S REVIEWED FOR CODE COMPLIANCE APPROVED DEC 0 6 2016 IC City of Tukwila BUILDING DIVISION RECEIVED CITY OF TUKWILA► NOV 29 2016 PERMIT CENTER General Notes No. I Revision/Issue I Date [Firm Name and Address — CMECHANICAL & CCi1tiTTI L>SE'IA�tICES, la'�1C IS- 'P I I I M' i.' ~S 642618TH ST E Travis Hull FIFE, WA 98424 253-926-9777 Project Name and Address Olympic Building HVAC Redistribution 18370 OLYMPIC AVE S Tukwila, WA 98188 W Vietnamese catnolic_ ", Qc� Community Wanke Cascade n 90 M Design Imports India Q x 8 Protime Sports c� a y �i`✓ersic/� Dr 0 Green River ^ 1$1 8 Sears Outlet Bralco Metals Cl? Y co Q' Zonar Systems, Inc o Coatings Unli co 18370 Olympic 'Avenue Genoa, A QoL Healthcare Company South . q Rainier Industries \` o S TOdd Bivd r Q 2 a S T odd Blvd ED O Emser Tile Seattle Grainger .—Industrial Supply t tai Cascade Engine Center Neighbors Relocation as Services � I- � - .c�, � Certifit Auto Body Parts A ni nn r A SMilXIIRPAML�1' Plan review ^,pproval is subject to errors and orn -sio o. Approval of consiruciian documents does nrit au Iron__ the violation of any adopted code or ordinance. Re slpt of approved f=ield Copy and conditions is acknoivlea d: By: Date. n City of Tul ila BUILDING DIVISION U hilachanical I -Electrical Plumbing was Piping � —tof Tukwila El' ` DIVEl01V SYMBOLS SUPPLY AIR DUCT RETURN AIR DUCT CEILING DIFFUSER RETURN GRILL EXHAUST FAN (DIRECT VENT) V' -r. © . REVISIONS No changes shall bo made to the scope Of work without prior approval of Tul(wila Building Division. NOTE: Fevisi and ons will require a new plan submittal may include additional plan review fees. GENERAL NOTES SITE INFO ADDRESS 18370 OLYMPIC AVE S Parcel 7888900153 Leaal Descriation SOUTHCENTER SOUTH INDUSTRIAL PARK LOT 18 OF TUKWILA AMENDED SHORT PLAT NO MF 78 -19 -SS RECORDING NO 7807210798 SD PLAT DAF - BEG SW COR LOT 16 PLAT OF SOUTHCENTER SOUTH INDUSTRIAL PARK TH N 78-36-10 W 360 FT TH N 11-23-50 E 698.25 FT TH ALG CURVE TO RGT RAD 110 FT ARC DIST 172.79 FT TH RU C/A 90-00-00 TH S 78-36-10 E 480 FT TH ALG CURVE TO RGT RAD 110 FT ARC DIST 172.79 FT THRU C/A 90-00-00 TH S 11-23-50 W 648.25 FT TH ALG CURVE TO LFT RAD 50 FT ARC DIST 78.54 FT THRU C/A 90-00-00 TH N 78-36-10 W TO POB DUCTWORK 1.1 ALL DUCT DIMENSIONS ON PLAN ARE CLEAR INSIDE DIMENSIONS, ADD 2" TO EACH DIMENSION TO OBTAIN OUTSIDE DIMENSION. ADD 4"TO EACH DIMENSION IF DUCTWORK IS ON THE EXTERIOR OF BUILDING. 1.2 THE FIRST NUMBER ON ALL DUCT DIMENSIONS IS THE WIDTH AND THE SECOND NUMBER IS THE HEIGHT. 1.3 MATERIALS WITHIN DUCTS OR PLENUMS SHALL HAVE A FLAME SPREAD RATING LESS THAN 25 AND A FLAME SMOKE DEVELOPMENT RATING LESS THAN 50, PER IMC 602.2.1. 1.4 SEAL ALL TRANSVERSE JOINTS FOR DUCTWORK WITH STATIC PRESSURE BETWEEN 1/2 INCHES AND 2 INCHES. DUCTWORK WHICH IS DESIGNED TO OPERATE AT PRESSURES ABOVE 1/2 INCH WATER COLUMN STATIC PRESSURE SHALL BE SEALED IN ACCORDANCE WITH STANDARD RS -7. 1.5 ALL DUCT GAUGES PER SMACNA, IMC 603-4. 1.6 ALL DUCT SUPPORTS PER SMACNA, IMC 603-10. 1.7 ATTACH DIFFUSERS AND GRILLES TO T -BAR GRID PER WA STATE & LOCAL CODES. 1.8 BALANCING DAMPERS ARE TO BE INSTALLED ON ALL BRANCH DUCTS OR DIFFUSERS. 1.7 Co de- F-cQ t t a v� : zo 1 S 1-1�L C, a Cv�Vrt.K S,te4 CN S REVIEWED FOR CODE COMPLIANCE APPROVED DEC 0 6 2016 IC City of Tukwila BUILDING DIVISION RECEIVED CITY OF TUKWILA► NOV 29 2016 PERMIT CENTER General Notes No. I Revision/Issue I Date [Firm Name and Address — CMECHANICAL & CCi1tiTTI L>SE'IA�tICES, la'�1C IS- 'P I I I M' i.' ~S 642618TH ST E Travis Hull FIFE, WA 98424 253-926-9777 Project Name and Address Olympic Building HVAC Redistribution 18370 OLYMPIC AVE S Tukwila, WA 98188 A ni nn r A SMilXIIRPAML�1' Plan review ^,pproval is subject to errors and orn -sio o. Approval of consiruciian documents does nrit au Iron__ the violation of any adopted code or ordinance. Re slpt of approved f=ield Copy and conditions is acknoivlea d: By: Date. n City of Tul ila BUILDING DIVISION U hilachanical I -Electrical Plumbing was Piping � —tof Tukwila El' ` DIVEl01V SYMBOLS SUPPLY AIR DUCT RETURN AIR DUCT CEILING DIFFUSER RETURN GRILL EXHAUST FAN (DIRECT VENT) V' -r. © . REVISIONS No changes shall bo made to the scope Of work without prior approval of Tul(wila Building Division. NOTE: Fevisi and ons will require a new plan submittal may include additional plan review fees. GENERAL NOTES SITE INFO ADDRESS 18370 OLYMPIC AVE S Parcel 7888900153 Leaal Descriation SOUTHCENTER SOUTH INDUSTRIAL PARK LOT 18 OF TUKWILA AMENDED SHORT PLAT NO MF 78 -19 -SS RECORDING NO 7807210798 SD PLAT DAF - BEG SW COR LOT 16 PLAT OF SOUTHCENTER SOUTH INDUSTRIAL PARK TH N 78-36-10 W 360 FT TH N 11-23-50 E 698.25 FT TH ALG CURVE TO RGT RAD 110 FT ARC DIST 172.79 FT TH RU C/A 90-00-00 TH S 78-36-10 E 480 FT TH ALG CURVE TO RGT RAD 110 FT ARC DIST 172.79 FT THRU C/A 90-00-00 TH S 11-23-50 W 648.25 FT TH ALG CURVE TO LFT RAD 50 FT ARC DIST 78.54 FT THRU C/A 90-00-00 TH N 78-36-10 W TO POB DUCTWORK 1.1 ALL DUCT DIMENSIONS ON PLAN ARE CLEAR INSIDE DIMENSIONS, ADD 2" TO EACH DIMENSION TO OBTAIN OUTSIDE DIMENSION. ADD 4"TO EACH DIMENSION IF DUCTWORK IS ON THE EXTERIOR OF BUILDING. 1.2 THE FIRST NUMBER ON ALL DUCT DIMENSIONS IS THE WIDTH AND THE SECOND NUMBER IS THE HEIGHT. 1.3 MATERIALS WITHIN DUCTS OR PLENUMS SHALL HAVE A FLAME SPREAD RATING LESS THAN 25 AND A FLAME SMOKE DEVELOPMENT RATING LESS THAN 50, PER IMC 602.2.1. 1.4 SEAL ALL TRANSVERSE JOINTS FOR DUCTWORK WITH STATIC PRESSURE BETWEEN 1/2 INCHES AND 2 INCHES. DUCTWORK WHICH IS DESIGNED TO OPERATE AT PRESSURES ABOVE 1/2 INCH WATER COLUMN STATIC PRESSURE SHALL BE SEALED IN ACCORDANCE WITH STANDARD RS -7. 1.5 ALL DUCT GAUGES PER SMACNA, IMC 603-4. 1.6 ALL DUCT SUPPORTS PER SMACNA, IMC 603-10. 1.7 ATTACH DIFFUSERS AND GRILLES TO T -BAR GRID PER WA STATE & LOCAL CODES. 1.8 BALANCING DAMPERS ARE TO BE INSTALLED ON ALL BRANCH DUCTS OR DIFFUSERS. 1.7 Co de- F-cQ t t a v� : zo 1 S 1-1�L C, a Cv�Vrt.K S,te4 CN S REVIEWED FOR CODE COMPLIANCE APPROVED DEC 0 6 2016 IC City of Tukwila BUILDING DIVISION RECEIVED CITY OF TUKWILA► NOV 29 2016 PERMIT CENTER General Notes No. I Revision/Issue I Date [Firm Name and Address — CMECHANICAL & CCi1tiTTI L>SE'IA�tICES, la'�1C IS- 'P I I I M' i.' ~S 642618TH ST E Travis Hull FIFE, WA 98424 253-926-9777 Project Name and Address Olympic Building HVAC Redistribution 18370 OLYMPIC AVE S Tukwila, WA 98188 W Vietnamese catnolic_ ", Qc� Community o-® Wanke Cascade n 90 M MIE. f BO Design Imports India Q 17-Y 17-11 11'-1�' 17-f s x 8 Protime Sports c� OE RK ` y A , ] � 4 0 -M ^ 1$1 P 8 Sears Outlet Bralco Metals Cl? Y FFt E Zonar Systems, Inc g A ni nn r A SMilXIIRPAML�1' Plan review ^,pproval is subject to errors and orn -sio o. Approval of consiruciian documents does nrit au Iron__ the violation of any adopted code or ordinance. Re slpt of approved f=ield Copy and conditions is acknoivlea d: By: Date. n City of Tul ila BUILDING DIVISION U hilachanical I -Electrical Plumbing was Piping � —tof Tukwila El' ` DIVEl01V SYMBOLS SUPPLY AIR DUCT RETURN AIR DUCT CEILING DIFFUSER RETURN GRILL EXHAUST FAN (DIRECT VENT) V' -r. © . REVISIONS No changes shall bo made to the scope Of work without prior approval of Tul(wila Building Division. NOTE: Fevisi and ons will require a new plan submittal may include additional plan review fees. GENERAL NOTES SITE INFO ADDRESS 18370 OLYMPIC AVE S Parcel 7888900153 Leaal Descriation SOUTHCENTER SOUTH INDUSTRIAL PARK LOT 18 OF TUKWILA AMENDED SHORT PLAT NO MF 78 -19 -SS RECORDING NO 7807210798 SD PLAT DAF - BEG SW COR LOT 16 PLAT OF SOUTHCENTER SOUTH INDUSTRIAL PARK TH N 78-36-10 W 360 FT TH N 11-23-50 E 698.25 FT TH ALG CURVE TO RGT RAD 110 FT ARC DIST 172.79 FT TH RU C/A 90-00-00 TH S 78-36-10 E 480 FT TH ALG CURVE TO RGT RAD 110 FT ARC DIST 172.79 FT THRU C/A 90-00-00 TH S 11-23-50 W 648.25 FT TH ALG CURVE TO LFT RAD 50 FT ARC DIST 78.54 FT THRU C/A 90-00-00 TH N 78-36-10 W TO POB DUCTWORK 1.1 ALL DUCT DIMENSIONS ON PLAN ARE CLEAR INSIDE DIMENSIONS, ADD 2" TO EACH DIMENSION TO OBTAIN OUTSIDE DIMENSION. ADD 4"TO EACH DIMENSION IF DUCTWORK IS ON THE EXTERIOR OF BUILDING. 1.2 THE FIRST NUMBER ON ALL DUCT DIMENSIONS IS THE WIDTH AND THE SECOND NUMBER IS THE HEIGHT. 1.3 MATERIALS WITHIN DUCTS OR PLENUMS SHALL HAVE A FLAME SPREAD RATING LESS THAN 25 AND A FLAME SMOKE DEVELOPMENT RATING LESS THAN 50, PER IMC 602.2.1. 1.4 SEAL ALL TRANSVERSE JOINTS FOR DUCTWORK WITH STATIC PRESSURE BETWEEN 1/2 INCHES AND 2 INCHES. DUCTWORK WHICH IS DESIGNED TO OPERATE AT PRESSURES ABOVE 1/2 INCH WATER COLUMN STATIC PRESSURE SHALL BE SEALED IN ACCORDANCE WITH STANDARD RS -7. 1.5 ALL DUCT GAUGES PER SMACNA, IMC 603-4. 1.6 ALL DUCT SUPPORTS PER SMACNA, IMC 603-10. 1.7 ATTACH DIFFUSERS AND GRILLES TO T -BAR GRID PER WA STATE & LOCAL CODES. 1.8 BALANCING DAMPERS ARE TO BE INSTALLED ON ALL BRANCH DUCTS OR DIFFUSERS. 1.7 Co de- F-cQ t t a v� : zo 1 S 1-1�L C, a Cv�Vrt.K S,te4 CN S REVIEWED FOR CODE COMPLIANCE APPROVED DEC 0 6 2016 IC City of Tukwila BUILDING DIVISION RECEIVED CITY OF TUKWILA► NOV 29 2016 PERMIT CENTER General Notes No. I Revision/Issue I Date [Firm Name and Address — CMECHANICAL & CCi1tiTTI L>SE'IA�tICES, la'�1C IS- 'P I I I M' i.' ~S 642618TH ST E Travis Hull FIFE, WA 98424 253-926-9777 Project Name and Address Olympic Building HVAC Redistribution 18370 OLYMPIC AVE S Tukwila, WA 98188 W Vietnamese catnolic_ ", Qc� Community Wanke Cascade n 90 M Design Imports India Q x 8 Protime Sports c� a y �i`✓ersic/� Dr 0 Green River ^ 1$1 8 Sears Outlet Bralco Metals Cl? Y co Q' Zonar Systems, Inc o Coatings Unli co 18370 Olympic 'Avenue Genoa, A QoL Healthcare Company South . q Rainier Industries \` o S TOdd Bivd r Q 2 a S T odd Blvd ED O Emser Tile Seattle Grainger .—Industrial Supply t tai Cascade Engine Center Neighbors Relocation as Services � I- � - .c�, � Certifit Auto Body Parts A ni nn r A SMilXIIRPAML�1' Plan review ^,pproval is subject to errors and orn -sio o. Approval of consiruciian documents does nrit au Iron__ the violation of any adopted code or ordinance. Re slpt of approved f=ield Copy and conditions is acknoivlea d: By: Date. n City of Tul ila BUILDING DIVISION U hilachanical I -Electrical Plumbing was Piping � —tof Tukwila El' ` DIVEl01V SYMBOLS SUPPLY AIR DUCT RETURN AIR DUCT CEILING DIFFUSER RETURN GRILL EXHAUST FAN (DIRECT VENT) V' -r. © . REVISIONS No changes shall bo made to the scope Of work without prior approval of Tul(wila Building Division. NOTE: Fevisi and ons will require a new plan submittal may include additional plan review fees. GENERAL NOTES SITE INFO ADDRESS 18370 OLYMPIC AVE S Parcel 7888900153 Leaal Descriation SOUTHCENTER SOUTH INDUSTRIAL PARK LOT 18 OF TUKWILA AMENDED SHORT PLAT NO MF 78 -19 -SS RECORDING NO 7807210798 SD PLAT DAF - BEG SW COR LOT 16 PLAT OF SOUTHCENTER SOUTH INDUSTRIAL PARK TH N 78-36-10 W 360 FT TH N 11-23-50 E 698.25 FT TH ALG CURVE TO RGT RAD 110 FT ARC DIST 172.79 FT TH RU C/A 90-00-00 TH S 78-36-10 E 480 FT TH ALG CURVE TO RGT RAD 110 FT ARC DIST 172.79 FT THRU C/A 90-00-00 TH S 11-23-50 W 648.25 FT TH ALG CURVE TO LFT RAD 50 FT ARC DIST 78.54 FT THRU C/A 90-00-00 TH N 78-36-10 W TO POB DUCTWORK 1.1 ALL DUCT DIMENSIONS ON PLAN ARE CLEAR INSIDE DIMENSIONS, ADD 2" TO EACH DIMENSION TO OBTAIN OUTSIDE DIMENSION. ADD 4"TO EACH DIMENSION IF DUCTWORK IS ON THE EXTERIOR OF BUILDING. 1.2 THE FIRST NUMBER ON ALL DUCT DIMENSIONS IS THE WIDTH AND THE SECOND NUMBER IS THE HEIGHT. 1.3 MATERIALS WITHIN DUCTS OR PLENUMS SHALL HAVE A FLAME SPREAD RATING LESS THAN 25 AND A FLAME SMOKE DEVELOPMENT RATING LESS THAN 50, PER IMC 602.2.1. 1.4 SEAL ALL TRANSVERSE JOINTS FOR DUCTWORK WITH STATIC PRESSURE BETWEEN 1/2 INCHES AND 2 INCHES. DUCTWORK WHICH IS DESIGNED TO OPERATE AT PRESSURES ABOVE 1/2 INCH WATER COLUMN STATIC PRESSURE SHALL BE SEALED IN ACCORDANCE WITH STANDARD RS -7. 1.5 ALL DUCT GAUGES PER SMACNA, IMC 603-4. 1.6 ALL DUCT SUPPORTS PER SMACNA, IMC 603-10. 1.7 ATTACH DIFFUSERS AND GRILLES TO T -BAR GRID PER WA STATE & LOCAL CODES. 1.8 BALANCING DAMPERS ARE TO BE INSTALLED ON ALL BRANCH DUCTS OR DIFFUSERS. 1.7 Co de- F-cQ t t a v� : zo 1 S 1-1�L C, a Cv�Vrt.K S,te4 CN S REVIEWED FOR CODE COMPLIANCE APPROVED DEC 0 6 2016 IC City of Tukwila BUILDING DIVISION RECEIVED CITY OF TUKWILA► NOV 29 2016 PERMIT CENTER General Notes No. I Revision/Issue I Date [Firm Name and Address — CMECHANICAL & CCi1tiTTI L>SE'IA�tICES, la'�1C IS- 'P I I I M' i.' ~S 642618TH ST E Travis Hull FIFE, WA 98424 253-926-9777 Project Name and Address Olympic Building HVAC Redistribution 18370 OLYMPIC AVE S Tukwila, WA 98188