HomeMy WebLinkAboutPermit M16-0182 - SOLA SALON STUDIOS - ROOFTOP UNITSSOLA SALON S1'LIDIOS 351 STRANDER BLVD M16-0182 City of Tukwila ' Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Inspection Request Line: 206-438-9350 Web site: http://www.TukwilaWA.gov MECHANICAL PERMIT Parcel No: 2623049064 Permit Number: M16-0182 Address: 351 STRANDER BLVD Issue Date: 1/19/2017 Permit Expires On: 7/18/2017 Project Name: SOLA SALON STUDIOS Owner: Name: REGENCY CENTERS LP Address: PO BOX 790830 C/O PROPERTY TAX DEPT, SAN ANTONIO, WA, 78279 Contact Person: Name: LAMAR MOORE Address: PO BOX 1455, MONROE, WA, 98272 Contractor: Name: PRECISE HEATING & COOLING LLC Address: PO BOX 1455, MONROE, WA, 98272 License No: PRECIHC8911-9 Lender: Name: Address: Phone: (206) 510-4250 Phone: (206) 861-2525 Expiration Date: 6/29/2017 DESCRIPTION OF WORK: INSTALL 4 NEW ROOFTOP UNITS, 3 TO GO ON EXISTING CURBS. INSTALL DUCT SYSTEM AND DIFFUSEERS TO SERVE EVERY STUDIO WITH SUPPLY, RETURN AND EXHAUST. Valuation of Work: $3,500.00 Fees Collected: $246.42 Type of Work: NEW Electrical Service Provided by: PUGEST SOUND ENERGY Fuel type: GAS Water District: TUKWILA Sewer District: TUKWILA Current Codes adopted by the City of Tukwila: International Building Code Edition: 2015 National Electrical Code: 2014 International Residential Code Edition: 2015 WA Cities Electrical Code: 2014 International Mechanical Code Edition: 2015 WAC 296-46B: 2014 Uniform Plumbing Code Edition: 2015 WA State Energy Code: 2015 International Fuel Gas Code: 2015 Permit Center Authorized Signature: Date: G "/ I hearby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this development permit and agree tothe c nditions attached to this permit. % Signature _ Date: 1 19 Print Name: �l (�Q K (J�(? 16* M This permit shall become null and void if the work is not commenced within 180 days for the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. PERMIT CONDITIONS: 1: The attached set of mechanical plans have been reviewed by The Tukwila Fire Marshals Office and are acceptable with the following concerns: 2: H.V.A.C. units rated at greater than 2,000 cfm require auto -shutdown devices. These devices shall be separately zoned in the alarm panel and local U.L. central station supervision is required. (City Ordinance #2437) 3: H.V.A.C. systems supplying air in excess of 2,000 cubic feet per minute to enclosed spaces within buildings shall be equipped with an automatic shutoff. Automatic shutoff shall be accomplished by interrupting the power source of the air -moving equipment upon detection of smoke in the main return -air duct served by such equipment. Smoke detectors shall be labeled by an approved agency for air -duct installation and shall be installed in accordance with the manufacturer's installation instructions. (IMC 606.1, 606.2.1) 4: Remote indicator lights are required on all above ceiling smoke detectors. (City Ordinance #2437) 5: Duct smoke detectors shall be capable of being reset from a single point near the alarm panel. (City Ordinance #2437) 6: Duct detectors shall send a supervisory signal only upon activation. (City Ordinance #2437) 7: All new fire alarm systems or modifications to existing systems shall have the written approval of The Tukwila Fire Prevention Bureau. No work shall commence until a fire department permit has been obtained. (City Ordinance #2437) (IFC 901.2) 8: An electrical permit from the City of Tukwila Building Department Permit Center (206-431-3670) is required for this project. 9: Contact The Tukwila Fire Prevention Bureau to witness all required inspections and tests. (City Ordinances #2436 and #2437) 10: Any overlooked hazardous condition and/or violation of the adopted Fire or Building Codes does not imply approval of such condition or violation. 11: These plans were reviewed by Inspector 511. If you have any questions, please call Tukwila Fire Prevention Bureau at (206)575-4407. 12: Work shall be installed in accordance with the approved construction documents, and any changes made during construction that are not in accordance with the approved construction documents shall be resubmitted for approval. 13: All permits, inspection record card and approved construction documents shall be kept at the site of work and shall be open to inspection by the Building Inspector until final inspection approval is granted. 14: Readily accessible access to roof mounted equipment is required. 15: All construction shall be done in conformance with the Washington State Building Code and the Washington State Energy Code. 16: There shall be no occupancy of a building until final inspection has been completed and approved by Tukwila building inspector. No exception. 17: Remove all demolition rubble and loose miscellaneous material from lot or parcel of ground, properly cap the sanitary sewer connections, and properly fill or otherwise protect all basements, cellars, septic tanks, wells, and other excavations. Final inspection approval will be determined by the building inspector based on satisfactory completion of this requirement. 18: Every occupied space other than enclosed parking garages and buildings used for repair of automobiles shall be ventilated in accordance with the applicable provisions of the International Mechanical Code. 19: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206-431-3670). 20: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center. 21: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. 22: ***MECHANICAL PERMIT CONDITIONS*** 23: All mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center (206/431-3670). 24: Manufacturers installation instructions shall be available on the job site at the time of inspection. PERMIT INSPECTIONS REQUIRED Permit Inspection Line: (206) 438-9350 1400 FIRE FINAL 0703 MECH EQUIP EFF 1800 MECHANICAL FINAL 0609 PIPE/DUCT INSULATION 0705 REFRIGERATION EQUIP 0701 ROUGH -IN MECHANICAL 0702 SMOKE DETECTOR TEST CITY OF TUKWILA Community Development Department ( ir"", Pc rnrit Censer • 6.300 Southcenter Blvd., SOIC loll Trrinvilo, W4 98188 htt /ww\v.Tukwila\l/A..;ov Mechanical Permit No. tog— Project No. Date Application Accepted: Date Application Expires: (For o. jive use 0171y) MECHANICAL PERMIT APPLICATION Applications and plans mist be complete in order to be (accepted tl>r plan review. Applications will not be accepted through the mail or by fax. **please print** SITE LOCATION Kinn Co Assessor's Tax No.; 2623049064 Site Address: 351 Strander Blvd Suite Number:_ Floor: Tenant Name: SOLA SALON STUDIOS New Tenant: ^0.....Yes El.. No PROPERTY OWNER — Name: Sola Salon Studios Address: 50 South Steele Street, Suite 1050 City: Denver State: CO Zip: 80209 CONTACT PERSON — person receiving all project communication Name: LaMar Moore Address: P.O. Box 1455 � �--------- City: Monroe Stab;: WA "Lip: 98272 Phone: (206) 510-4250 Fax: Email: latnar@preciseheatandcool.corrt MECHANICAL CONTRACTOR INFORMATION Company Name: precise Heating and Cooling Address: P.O, Box 1455 City: Monroe State: WA Zip: 98272 Pho"e: (206) 510-4250 Fax: Contr Reg No.: PRECIHC891 L9 Exp Date: 06/27/2017 Tuk\vila Business License No.: BUS -0996560 Valuation of project (contractor's bid price): Describe the scope of work in detail: Install 4 New rooftop units, 3 to go on exising curbs. Install duct system and diffusers to serve every studio with supply, return, and exhaust. Use: Residential: New .......... ❑ Replacement ........ ❑ Commercial: New.......... Replacement........0 FueITr e: Electric..... V Gas....... V Other:.- --- _---------------_— - —_- ------ 11 'App calions,Ponns. A pp hcalions On Lnw`2016 Apphcation Wchz cal Pennn Apph,lo- Rrcised 1-4- 16 docs Revised January ?010 Page t of 2 bh Indicate type of mechanical work being installed and the quantity below: Unit Type Qty Furnace <I 00k btu Residential, Nighttime Furnace >I 00k btu 47 Floor furnace Suspended/wall/Moor mounted heater 40 Hood and duct_ Appliance vent _ Repair or addition to heat/refrig/cooling system _ Air handling unit <10.000 cfm 4 Unit Type Qty Air handling unit >I 0.000 c fm Residential, Nighttime C(va,orator cooler 47 Ventilation I1111 connected to simalc duct Ventilation system 40 Hood and duct_ 57 dB(A) Incinerator — domestic Commercial Incinerator ----- comm/industrial 47 dB(A) Unit Type Qty Fire damper Residential, Nighttime Di1'fIse r 47 rher,,,ostat ^--� Wood/gas stove 40 I:;mergencv generator 57 dB(A) Other mechanical equipment Commercial 57 dl3(A) 47 dB(A) Boiler/Compressor Qty 0-3 lip/ 100.000 but 3-15 hp/500.000 but 15-30 lip/ 1.000.000 but .30-50 hp/I,750,000 btu 50+ lip/1.750,000 btu Noise: Mechanical units need to be in compliance with the Titkwila Noise Code. Maximum permissible sound levels are based on From where the sound is created and where the sound is heard. Additionally. if sound can be heard from within a house at night in a residential zone it may not be allowed. For more details. see TMC 8.22 District of Sound Producing Source District of Receiving Property Residential, Daytime* Residential, Nighttime Commercial Industrial Residential 55 dB(A) 45 dI3(A) 57 dB(A) 60 dB(A) Commercial 57 dl3(A) 47 dB(A) 60 dB(A) 65 dB(A) Industrial 60 d13(A) 50 dB(A) 65 dB(A) 70 dB(A) *Daytime means 7AM-1011M, Monday through Friday and NAM -1011M, Saturday, sunaay ana state-recognizea nouaays. A few sounds are exempt from the noise code. including: Warning devices: Construction and property maintenance during the daytime horn's (7am-10pm): Testing of backup generators during the day. PERMIT APPLICATION NOTES - Value of construction — in all cases. a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the permit center to comply with Current fec schedules. Expiration of plan review — applications R01- Which no permit is issued vvithin 180 days lollowing the date ol'application shall expire by limitation. The building ollicial may grant one extension oftime for additional periods not to exceed 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). I IIF REBY CER -I IFY TI IAT I IIAVI_ READ AND EXAM INI'll) 'I Ii IS A13I11_ICATION AND KNOW THI_' SAME'10 13F. TRUE: UNDFIR PENALTY 01' PERJURY BY TIII LAW'S 01 TI It: STA I F. OF WASHINGTON. ANI) 1 AM AUTI TORI/1_:D TO APPLY FOR THIS PERMIT. BUILDING OWNEJ2 OR AUTHQAIZED A Signature: IAV"- (. Print Name: Kirk Offerdahl Mailing Address:P.O. Box 1455' I I.',Applicauons\Forms-Applleatons (hi Line'016 Apphcaiions.Mechwwal Perms Appbcannn Ke,u d I - .L In docc Ke•+ised Januar• 2019 bl, Day Telephone - Monroe City Date: 12/05/2016 (425) 319-3428 WA 98272 State Zip Page 2 o1'2 DESCRIPTIONS ACCOUNT QUANTITY ' 1 PermitTRAK $246.42 M16-0182 Address: 351 STRANDER BLVD Apn: 2623049064 $246.42 MECHANICAL $236.94 PERMIT ISSUANCE BASE FEE R000.322.100.00.00 0.00 $32.50 PERMIT FEE R000.322.100.00.00 0.00 $157.05 PLAN CHECK FEE R000.322.102.00.00 0.00 $47.39 TECHNOLOGY FEE $9.48 TECHNOLOGY FEE TOTAL FEES PAID BY RECEIPT: R9976 R000.322.900.04.00 0.00 $9.48 $246.42 Date Paid: Monday, December 05, 2016 Paid By: KIRK CIFFERDAHL Pay Method: CREDIT CARD 09735G IF Printed: Monday, December 05, 20161:17 PM 1 of 1 ��' I,�iSY57EM5 INSPECTION RECORD Retain a copy with permit M)6 - 616 INVICTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-36 Permit Inspection Request Line (206) 438-9350 Project: Type of Inspection: Address: 351 44? Date Called: Special Instructions: Date Wanted: m. (g % % m. Requester: /—AMA -9 Phone No: -/-0 14 Approved per applicable codes. EJ Corrections required prior to approval. paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. p INSPECTION RECORD lL� Retain a copy with permit Al Je ~ g2 INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Project: Type of Inspection: -Sou- SAL -OAU 1 TI Cr Address: Date Called: 35-1 57",OZI? Special Instructions: Hate Wanted: ,2 -22-17 p.m Requester: !./i'f' 4,01V7..— Phone No: 20-25-6 nspector: REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd.. Suite 100. Catl to schedule reinspection. INSPECTION RECORD Retain a copy with permit I M)& -0 INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd.., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 'ct: C j/p PKM J w� T e of Inspection: /, ] �� ypp� y 4 (rA04AAJ X4 L Address: 351 Date Called: Special Instructions: Date Wanted: / a.m. �Cv7 P.m. Requester Phone No: 11 Approved per applicable codes. LJ Corrections required prior to approval. MENTS: L IInspector: 0 IUate:.2 —1(,P 17 I REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. / INSPECTION RECORD ( Retain a copy with permit 06 r 0/97ZINSPECTION N0. PERMIT N0. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350JMA�%VI-111 Project: T e of Inspection Address:Date AA Called: Special Instructions: . Date Want .-1M- 16- /'r p.m. ;M16-11 Requeste .. /41-449 Phone No: 2016 S" -lo q'2 Approved per applicable codes. LJ Corrections required prior to approval. Inspector: Date: REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Project: Type of Inspection: S'044 Aa11?h5;C4477 _AJ ,PAwlr Address: Date Called: Special Instructions: Date Wanted: a.m. M. Requester: MYYKA Phone No: ab C@ ,57 7i * 2.5-6 Approved per applicable codes. LJ Corrections required prior to approval. COMMENTS: 'W 14eOa1ey &) �niasz_4?9t3,AgD Inspector: Date: F1 REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. INSPECTION RECORD 1,04 Retain a copy with permifi INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Project: sant s q-�oN Type of Inspection: o1P7Ke11KV1o'1L Address: 35/ -:5-1—A ofND,,Q BLVD Date Called: Special Instructions: (ed Date Wanted: m P.m. Requester: Phone No: 0 Approved per applicable codes. LJ Corrections required prior to approval. Inspector: K:C-e� Date — 1� —f / REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. INSPECTION RECORD Retain a copy with permit INSPECTION: NUMBER PERMIT NUMBERS CITY OF TUKWILA FIRE DEPARTMENT 206-575-4407 Project: / f ection: Type of? Address: Suite #: Contact Person: Special Instructions: Phone No.: Needs Shift Inspection: Sprinklers: Fire Alarm: Hood & Duct: Monitor: Pre -Fire: Permits: Occupancy Type: U $100.00 REINSPECTION FEE REQUIRED. You will receive an invoice from the City of Tukwila Finance Department. Call to schedule a reinspection. Billing Address Attn: Company Name: Address: City: State: Zip: Word/Inspection Record Form.Doc 3/14/14 T.F.D. Form F.P. 113 Precise Heatin & Coolin LL RECEIVE® AIR OUTLET — TEST REPORT P.O. Box 1455 g g �I OF TUKWILA Monroe Washington 98272 M- AR 0 6 2097 Phone: 206-510-4250 Project: SOLA SALON STUDIOS PERMIT CWEIRystem or Unit: VARIES - SEE OUTLET TYPE Location 351 Strander Blvd, Tukwila 98188 Outlet Manufacturer: AREA SERVED No. OUTLET TYPE SIZE DESIGN CFM PREILIMINARY CFM FINAL CFM STUDIO 1 EG -2 8 70 100 70 STUDIO 2 2 EG -2 6 70 41 61 STUDIO 3 3 EG -2 8 140 123 129 STUDIO 4 4 EG -2 8 140 128 132 STUDIO 5 5 EG -2 8 140 126 125 STUDIO 6 6 EG -2 6 70 68 63 STUDIO 7 7 EG -2 6 70 83 68 STUDIO 8 8 EG -2 6 70 48 63 STUDIO 9 9 EG -2 6 70 55 58 STUDIO 10 10 EG -2 6 70 134 76 STUDIO 11 11 EG -2 6 70 127 62 STUDIO 12 12 EG -2 8 140 254 126 STUDIO 13 13 EG -2 6 70 100 75 STUDIO 14 14 EG -2 6 70 37 64 STUDIO 15 15 EG -2 6 100 48 95 STUDIO 16 16 EG -2 6 100 0 81 STUDIO 17 17 EG -2 6 70 0 59 STUDIO 18 18 EG -2 8 140 177 142 STUDIO 19 19 EG -2 8 70 35 61 STUDIO 20 20 EG -2 6 70 60 66 STUDIO 21 21 EG -2 8 70 43 60 STUDIO 22 22 EG -2 6 70 0 83 STUDIO 23 23 EG -1 6 70 86 69 STUDIO 24 24 EG -1 6 70 74 85 STUDIO 25 25 EG -1 6 70 122 64 STUDIO 26 26 EG -1 6 70 73 73 STUDIO 27 27 EG -1 6 70 91 74 STUDIO 28 28 EG -1 6 70 88 80 STUDIO 29 29 EG -1 8 140 138 139 STUDIO 30 30 EG -1 1 6 1 70 1 83 1 85 NOTES: TOTAL 2 EXHAUST SYSTEMS THROUGH THE BUILDING, SEE OUTLET TYPE FOR WHICH CORRESPOND TO THE UNIT T6EST DATE: 3/3/2017 READINGS BY: ASHLEY AVR-PASCUAL PA6), OF 2 t Precise Heating & Cooling LLC P.O. Box 1455 Monroe Washington 98272 Phone: 206-510-4250 Project: SOLA SALON STUDIOS AIR OUTLET — TEST REPORT H.V.A.C. System or Unit: VARIES - SEE OUTLET TYPE Location 351 Strander Blvd, Tukwila 98188 Outlet Manufacturer: AREA SERVED No. OUTLET TYPE SIZE DESIGN CFM PRELIMINARY CFM FINAL CFM STUDIO 31 31 EG -1 6 70 87 85 STUDIO 32 32 EG -1 6 70 92 70 STUDIO 33 33 EG -1 6 70 93 80 STUDIO 34 34 EG -1 8 100 90 94 STUDIO 35 35 EG -2 6 100 0 77 STUDIO 36 36 EG -1 6 100 90 112 STUDIO 37 37 EG -2 6 70 0 76 STUDIO 38 38 EG -1 6 100 73 90 STUDIO 39 39 EG -2 6 70 0 73 STUDIO 40 40 EG -2 6 70 41 61 WOMENS ADA 41 EG -2 6 70 110 76 WOMENS #2 42 EG -2 6 70 130 73 WOMENS #1 43 EG -2 6 70 124 71 MENS 44 EG -2 6 70 108 72 LAUNDRY 45 EG -1 10 250 255 260 46 47 48 49 50 51 52 53 54 55 56 57 58 59 NOTES: TOTAL 2 EXHAUST SYSTEMS THROUGH THE BUILDING, SEE OUTLET TYPE FOR WHICH CORRESPOND TO THE UNIT TEST DATE: 3/3/2017 READINGS BY: ASHLEY AVRA-PASCUAL PAGE 2 OF 2 2012 Washington State Energy Code Compliance Forms for Commercial, Group R1, and > 3 story R2 and R3 D7 Q pz ­„ q �f­A -1 au R1 Revised Sent 2015 LV IG QC C3 we i_n Project info I., .., .,,., I„ - ., .., ..,.,-. Project Address: SOLA SALON STUDIOS Date 12/15/2016 351 STRANDER BLVD For Building Dept. Use TUKWILA, WA 98188 Applicant Name: PRECISE HEATING AND COOLING Applicant Address: P.O. BOX 1455, MONROE, WA, 98272 Applicant Phone 206-510-4250 HVAC Air Distribution System Schedule List all HVAC systems that have the capability to provide heating and/or cooling to the spaces they serve. Fan System ID Speed Control (Note 1) System Total Fan Power Nameplate HP Calculation Description (Note 2) (Note 3) AHU-1 CV ROOFTOP AIR HANDLER 1.5 AHU-2 CV ROOFTOP AIR HANDLER 1.5 AHU-3 CV ROOFTOP AIR HANDLER 1.5 AHU-4 CV ROOFTOP AIR HANDLER 1.5 Note 1 - Constant Volume (CV), Variable Air Volume (VAV), or Hospital/Lab CV system that qualifies for VAV budget per C403 ?_ 1Q.1 Exception 1. Single zone VAV systems shall comply as CV. Note 2- Enter the total nameplate hp of all fans associated with the delivery and removal of conditioned air by the system. Include all supply, return/relief, exhaust and exhaust hoods (> 1 hp), make-up air, dedicated outside air (DORS), booster fans, and series fan -powered terminals. VAV parallel fan powered terminals and economizer relief fans do not need to be included if the fans do not operate at peak conditions. Note 3 - Indicate if MECH-FANSYS form is required (Yes), or the system is not required to provide this information because it has a combined total nameplate motor hp less than 5 hp (< 5 hp) or the system is ventilation only and thus has no heating or cooling capacity (No). MECH-FANSYS Forms A MECH-FANSYS form shall be provided for each system with total nameplate hp greater than 5 hp. Select Add Fan System Form) to generate an additional form. Added forms can be deleted with button in cell E38 of t ad (F1 F CORRECTION LTR# - I L xwp L, M1b**_016Z CODE UUMFLIANUt APPROVED JAN 0 6 2017 City of Tukwila BUILDING DIVISION CITY OF TUK® ILA DEC 30 2016 PERMIT CENTER Unti tl ed LOAD CALCULATIONS PROJECT NAME- SOLA SALON STUDIOS TOTAL BUILDING LOADS SUMMARY sensible Latent -Total Heating Clg BTUH Clg BTUH Clg BTUH BTUH Roofs 7,703 7,703 25,333 walls 568 568 5,396 Partitions 1-0,400 1.0,400 20,800 windows 12,057 1.2,057 17,240 Equipment 2.04,574 204,574 Lighting 26,225 26,225 People 19,494 1.8,720 38,214 ZLatent 0 0 ventilation 40,583 5,991. 34,593 40,32.6 Infiltration 24 4 21 1-03 Perimeter Slab 8,930 Ducting 0 0 0 System Fans 0 0 Bldg. -totals 321,629 1.2,726 334,354 118,128 whole Building ZONE 1. of 1 LOAD SUMMARY Zone Peak :July Sensible C1g BTUH Roof walls Partitions windows Equipment Lighting People ZL.atent ventilation Infiltration_ Perimeter Slab zone Totals T i me 1.400 Latent Total C1 BTUH Clg BTUH 7,703 7,703 25,333 568 568 5,396 10,400 10,400 0 1.2,057 12,057 1.7,240 2.04,574 2.04,574 26,22.5 26,22.5 19,494 1.8,720 38,21.4 0 0 40,583 -5,991. 34,593 40,326 24 4 21. 1.03 321,629 1.2 , 726 SYSTEM 1 SUMMARY Tons of cooling System Name Total cooling load Total sensible cooling load Ratio of sensible to total Latent: Cooling Load ventilation Air Mode Ambient dry bulb temp. Ambient vvet bulb temp. Air Supply DSch. Mode Supply Air CFM Supply Air Dry Bulb Temp. Supply Air wet Bulb Temp. Supply Air Rel. Humidity Supply Air Enthalpy btu/lb REVIEWED FOR E COMPLIANCE APPROVED Hea i ng JAN 0 6 2017 BT H City of Tukwila BUILDING DIVISION rORRECTION LTR#IV--- 8,930 334,354 1181 RECEIVED CITY OF TUK0LA 27.9 UN111. 334,354 321,629 0.962 12,72.6 Ambient Air 86.0 66.0 Temp f=ixed 12,853 55.0 53.9 ` 93.3 23. .1.3 Page 1 DEC 30 2016 PERMIT CENTER . / Outside ventilation [oil Inlet Dry bulb [oil Inlet wet bulb system heating load Untitled air cfm 3'354 temp. 77.24 temp. 63.63 1I8,I20 Page 2 I SHUTLER — CONSULTING ENGINEERS, Inc. 12503 Bel -Red Road, Suite 100 Bellevue, Washington 98005 (425) 450-4075 FAX (425) 450.4076 STRUCTURAL CALCULATIONS FOR: NEW & REPLACEMENT HVAC UNITS -- SOLA SALON 351 STRANDER BLVD. TUKWILA, WASHING'T'ON PROPOSED BY: PRECISE HFATING &COOLING PO BOX 1455 MONROE, WA 98272 (206) 51.0-4250 JOB Sola Salon SHEET NO. COVER OF CALCULATED BYjch DATE 12/29/2016 CHECKED BY DATE_ SCALE _ JOB NUMBER 16-01.89 $ ? . EVIEWED FOR '—LOCHE COMPLIANCE .. . QPROVED JAN 0 6 2017 I �..... DESIGN CRITERIA: Ci fv of Tukwila BUILDING DIVISeC)INI CODE .................................. INTERNATIONAL BUILDING CODE, 2015 EDITION ROOD LIVE LOAD ................. 25 PSP SNOW LOAD, Is=1.0 WIND L,OAD......................... 110 MPH ZONE, EXPOSURF,'B', Iw-1.0 SEISMIC ZONE ..................... SITE CLASS 'I)', Sds 0.972, ap=2.5, Rp=6.0, Ip -1.0 CORRECTION LTR #_I_ m 16*1- 0 1 94z RECEIVED CITY OF TtUKWILA DEC 30 2016 PERMIT CENTER AM O SHUTLER ® CONSULTING ENGINEERS Inc. 12503 Bel—Red Road, Suite 100 Bellevue, Washington 98005 (425)450-4075 FAX: (426)450-4076 0 HEj JoB SOLA SALON �E WASI� C9 Tukwila, Washington _, ?G' �' SHEET NO SKS-1Nr OF CALCULATED BY JH DATE 12-28-16 SCALE NOTED Job No• 16-01.89 31757 'RFs JOR A L s�aNA L A0'_n" e n'_n" PARTIAL ROOF FRAMING PLA •SCALE±: , YB"=1'-0" NOTES: 1) VERIFY EXISTING COND TONS,� DIMENSIONS INy; T14F RELD NOTIFY ENGINEER OF brFEE�EN'CES, 2) FOUR UNITS TO DE INSTA`i~.LE1• — �PI_A'CE ONLY,"UNE UNIT ON ANY JOIST. C m > s A SHUTLERrr_17"l H Eq ®� ® CONSULTINGW AS11 ®®® ENGINEERS Inc.,�, 12503 Bel—Red Road, Suite 100 �" "' •�G . Bellevue, Washington 98005 , � (425)450-4075 FAX: (425)450-4078 1757OR L NA L JOB SOLA SALON Tukwlla, Washington SHEET NO SKS-2 OF CALCULATED BY JH DATE 12-28-16 SCALE NOTED Job No. 16-01.89 SECTION A/SKS-2. SCALE; 3/a'=1'-0" SHUTLER ®®® CONSULTING ENGINEERS Inc. 12503 Bel -Red Road, Suite 100 Bellevue, Washington 98005 425)450-4075 FAX: (425)450-4078 TRUSS PER PLAN (TYP.) ✓�' WASIllu Baa/ 357 s17 I4AL ►L6NA L EAG\ 11 Joe SOLA SALON Tukwila, Washington SHEET NO SKS-3 OF CALCULATED BY JH DATE 12--28-16 SCALE NOTED Job No. 1601.89 uvnr i "IIT & __R PLAN SECTION-, B/SKS-3. SCALE: 3/4"=1'-0" SCREWS SIDE 12 "CREWS SIDE 12 0D 200 v/6•-# 10x3° ;CREWS (TYP.) SHUTLER CONSULTING ENGINEERS, INC 12503 Bel -Red Rd., Suite 100 Bellevue, WA 98005 (425) 450-4075 FAX (425) 450-4076 SHF.F1 NO._-._-- --.---�1 -- --- OF CAI_CULATFD BY DATE. SCAI_F: I 1 • t • I � -- T ; I O SHUTLER CONSULTING ENGINEERS, INC 12503 Bel -Red Rd., Suite 100 Bellevue, WA 98005 (425) 450-4075 PAY ld')Cl Arn_A(M; JOB SHEET NO.. — --- -- - OF...- -- CALCULATED BY �/ ` D✓/�--_ DATE-_...� / 4ll ---- _. SCALE w 00, 1 ... OF) _ Vj 1. . --- t� -- , - 1 - - - Qs __i-- t ��-6f - - - _ - -,-- ti AMAMMIMM SHUTLFR NMUNIMM CONSULTING ff"'"MM ENGINEERS, INC 12503 Bel -Red Rd., Suite 100 Bellevue, WA 90005 (425) 450-4075 FAX (425) 450-4076 JOB SHEF1 NO ­ CALCULATED 13Y 1-fO DATE / 9, - Y4� .1 � SCALE OF Aq- A- -z- aj- U -Atal 8HUTLB0 MMM11=11 CONSULTING §�W--------ENGINEERS, INC 12503 Bel -Red KJ,Suite 10O Bellevue, \w&9u0O5 (425) 450-4075 FAX (4%5)4GO'4O76 Joo–_____ SHEET NO. � '-------'--- - — nmCuLAr onv moe.'__�_-Lx��z�9���l��_�-__-___----__-____' 12�477 -5 - Roof Toa HVAC Unit - lateral loads Seismic - Sds 0.972 ap 2.5 Sd, 0.544 RP 6.0 Ip 1.0 Fp 0.486 wt Wind - Speed 110 inph KZ 0.70 Exposure B K, 1.00 Kd 0.85 q 18.43 psf I 1.00 i Fp - ws 21.0 psf GC, - horiz., 1.90 Fv - ws - _ 16.6 psf GC, - vert. 1.50 I i I I r Design Maps Summary Report lrttp://eaithduake.usgs.gov/desigumaps/us/sumnlary.php?templdiel m... E,MS Design Maps Summary Report User -Specified Input Building Code Reference Document 2012/2015 International Building Code (which utilizes OSGS hazard data available in 2008) Site Coordinates 47.460N, 122.26°W Site Soil Classification Site Class D - "Stiff Soil" Risk Category I/II/IIT t { a. lz t 3 Ike n t �f►11i kS 1'4*P1fi. t� °. USGS-Provided Output }� Ss = 1.459 g SMS = 1.459 g S„y = 0.972 g Sl = 0.544 g SM1 = 0.816 g Sol = 0.544 g For Information on how the SS and S1 values above have been calculated from probabilistic (risk -targeted) and deterministic ground motions In the direction of maximum horizontal response, please return to the application and select the "2009 NEHRP" building code reference document. MCEa Response Spectrum Design Response Spectrum 1.65 1.10 1.50 1.00 1.35 0.90 1.20 0.80 1.05 0.70 a' 0.90 dJ 0.60 M V�pp O75--------- --- - - - __._.._ .. . 0.60 0.40 0.45--0.30 0.30 0.20-- 0.15.- 0.10 0.00f -i i F- i 0.00 1 0.00 0.20 0.40 0.60 0.90 1.00 1.20 1.40 LGO 1.00 2.00 0.00 0.20 0.40 0.60 0.80 1.00 1.20 1.40 1.60 1.00 2.00 Period, T (sec) Period, T (sec) Although this Information is a product of the U.S. Geological Survey, we provide no warranty, expressed or implied, as to the accuracy of the data contained therein, This tool Is not a substitute for technical subject -matter knowledge. I of 1 12/24/2016 12.:13 PM T MYORK' SUBMITTAL DATA For: Quotation Order #: Date: 10/28/2016 Project: SOLA Project #: NN10281606 Location: Purchaser: PRECISE-LAMAR Submitter: YORK -NOAH Unitary Sales loos vt 5.9.0 mr (qm- , 6 ___ I - , a z Infonnation is subject to change without notice Check local codes. REVIEWED FOR CODE COMPLIANCE APPROVED JAN 0 6 2017 City of Tukwila BUILDING DIVISION RECEIVED CITY OF TUKWILA DEC 0 5 2016 PERMIT CENTER Printed 10/28/2016 a Date 10/28/2016 Project Name WYORK " SOLA Project Number N N 10281606 Client I Purchaser PRECISE-LAMAR Submittal Summary Page Qty Tag # Model # JZXG08D4B3AA2B111A2 Description 3 5 WKS- 7.5 Ton, Two Stage Cooling, York Direct Fit Single Packaged R - FACTORY 410A Air Conditioner, 11.0 EER / 11.5 IEER, 125 Mbh Two Stage BLD Input Low Heat Aluminized Gas, Gas Heat, 460-3-60 • VFD IntelliSpeed • Dry Bulb Economizer (Downflow only) (with Barometric Relief) with Economizer Fault Detection & Diagnostic (Meets ASHRAE 90.1- 2013, IECC 2015, California Title 24, AMCA 511) • Medium Static Belt Drive Blower • Simplicity® SE Controller including Discharge Air, Return Air, and Outdoor Air Temperature Sensors • Return Air Smoke Detector • Microchannel All Aluminum Condenser Coil, Copper tube/Aluminum fin Evaporator Coil 3 2PM04700224 Phase Monitor Kit 1 ZE060H12B4C1EAA1A1 Single Stage Cooling, York Small Sunline Single Packaged R -410A Air Conditioner, 5 Ton, 11.8 EER / 14.0 SEER, 125 MBH Input, Single Stage Gas Aluminum Steel, 460-3-60 • Dry Bulb Economizer and Hood (No Barometric Relief Damper) with Economizer Fault Detection & Diagnostic (Meets ASHRAE 90.1-2013, IECC 2015, California Title 24, AMCA 511) • 1.5 HP Standard Static Belt Drive Blower • 1" Throwaway Filters • SimplicityO SE Controller including Discharge Air, Return Air, and Outdoor Air Temperature Sensors • Return Air Smoke Detector • Microchannel All Aluminum Condenser Coil, Copper : tube/Aluminum fin Evaporator Coil • Galvanized Steel Drain Pan • Standard Access Doors 1 1 RD0410 Barometric Relief Damper with Hood Kit (Downflow Unit or Duct Mounted) 1 1 RC0434 Roof Curb - 14" High, Flat, Uninsulated, Full Perimeter (Shipped Knocked Down) ►J, Equipment start-up and commioning by a factory Haired technicrn is recommended. Contact your supplying distributor of sales representatMe for additional information & guidance. 4 'i i, Unitary Sales 1'001 v1 5 9 0 Information is • ubjad In change without notice CheCk local codes Printed 101812016 vw�YORK" Project Name: SOLA — Quantity: 3 Tag #: 5 WKS -FACTORY BLD Cooling Performance �otal gross capacity Sensible gross capacity Total net capacity Sensible net capacity Efficiency (at ARI) Integrated eff. (at ARI) Ambient DB temp. Entering DB temp. Entering WB temp. Leaving DB temp. Leaving WB temp. P^wer input (w/o blower) (S xlnd power___. Refrigerant Refrigerant type Sys1 _§ S2 Direct Fit (3-12.5 Ton — - Page:3 Package) L526 Single Package R-41 OA Air Conditioner Unit Model #: ZXG08D4B3AA2B111A2 -- — --- ---- — —' System: ZXG08D4B3AA2B111A2 (3) 94.9 MBH 67.4 MBH 90.0 MBH 62.5 MBH 11.00 EER 13.10 IEER 95.0 °F 80.0 °F 67.0 'F f 59.2 F I r 57.0 °F G.63 kW�� 84 dB(A) R -410A 4 lbs 8o/ ; ► 4 lbs 12 oz Gas Heati_ng Performan_ ce 17,5 Ton Entering temp. 60 I ,Heating output capacity (Max) output M 100 MBH All units are manufactured at an ISO 9001 registered facility and each 9 Y Supply air 3000 CFM I rooftop is completely computer -run tested prior to shipment. Heating input capacity (Max) 125 MBH ! Unit Features Leaving DB temp. 1 Air temp rise 90.9 `F 30.9 + Two Stage Cooling SSE 80.0 % 125 Mbh Two Stage Input Low Heat Aluminized Gas Stages 2 • Full perimeter base rails with built in rigging capabilities Supply Air Blower Perform_ a_ nce i • Either supply and/or return can be field converted from vertical to horizontal -- - — Supply air 3000 CFM configuration without cutting panels. Ext. static pressure 0.6 IWG • Unit Cabinet Constructed of Powder Painted Steel, Certified At 1000 Hours Addl. Unit Losses (Options/Accessories) 0.17 IWG Salt Spray Test (ASTM B-117 Standards) Blower speed 815 RPM . Scroll Compressors Max BHP of Motor (including service factor) 2.90 HP . Dry Bulb Economizer (Downflow only) (with Barometric Relief) with Duct location Bottom Motor rating 2.90 IIP Economizer Fault Detection & Diagnostic (Meets ASHRAE 90.1-2013, IECC • Actual required BHP 1.56 1 iP2.015. California Title 24, AMCA 511) Power input 1 44 kW Medium Static Belt Drive Blower F.,IevaUon 0 ft1 • Replacement filters: 4 - (16" x 20"). Unit accepts 2" wide filter ' tDrive type BF.L.T ; . Solid Core Liquid Line Filter Driers Electrical Data _ _ • Unit Ships with 2" Throwaway Filters with a Standard Filter Rack that will Power supply 460-3-60 Accept up to 4" Filters Unit min circuit ampacity 20.4 Amps I • Short Circuit Current: 5kA RMS Symmetrical Unit min over -current protection Unit max over -current protection 25 Amps 25 Amps Single Point Power Connection —_ _ v DimenSipnS &Weight • Microchannel All Aluminum Condenser Coil, Copper tube/Aluminum fin Evaporator Coil Hgl 41 in. Len 87 in. Wth Weight with facto installed options 62 in. 963 lbs. I BAS Controller Clearances Simplicity SE Controller including Discharge Air, Return Air, and Outdoor Air Temperature Sensors Right 18 in. Front 48 in. Back in. Standard Unit Controller: Simplicity SE Control Board P y � fop _72 in. Bottom. - 1 in. Left _ t 12 2 in. J I Note. Please refer to the tech guide for listed maximums tatic pressures Safely Monitoring - Monitors the high and low-pressure switches, the freezestats, the gas valve, if applicable, and the temperature limit switch on AMERICAN .i'� �/ gas and electric heat units. The unit control board will alarm on ignition failures, safety lockouts and repeated limit switch trips. ��---�us- = r. An Inte rated Low -Ambient Control Anti -Short C de P t t L d L I unitary Sales Tool 0 5 9.0 V y Dr- ec ion, ea - ag, Fan On and Fan off Delays, Low Voltage Protection, On -Board Diagnostic and Fault Code Display. Allows all units to operate in the cooling mode down to 0'F outdoor ambient without additional components or intervention. Warranty • One (1) Year I imited Warranty on the Complete Unit • Five (5) Year Warranty - Electric Heat Element • Five (5) Year Warranty - Compressors • Ten (10) Year Warranty - Aluminized Steel Tubular Heat Exchangers i Information s subject is rhanoo without roliro Check local nodes. Printed 1012812016 Project Name: SOLA Quantity: 3 Tag #: 5 WKS -FACTORY BLD Direct Fit (3-12.5 Ton Page:4 Package) L526 Single Package R-41 OA Air Conditioner Unit Model #:-ZXG0804133AA26111A21 System: ZXG08D4B3AA2B111A2 (3) Factory Installed Options ZXG08D4B3AA2B111A2 Product Category: Heat Type: Nominal Cooling Capacity: Heat Size: Voltage: Airflow: Airflow Options: Coil Options: Controls: Sensor Options: Economizer / Damper: Convenience Outlet: Electrical Options: Cabinet Options: Special Options: Product Generation: • 2PM04700224 - Phase Monitor Kit (1.0 lbs) Unitary Sales Tool 0.5 9.0 York Direct Fit Single Packaged R -410A Air Conditioner Gas Heat 7.5 Ton Two Stage Cooling 11.0 EER / 11.5 IEER 125 Mbh Two Stage Input Low Heat Aluminized Gas 460-3-60 Medium Static Belt Drive Blower VFD IntelliSpeed Microchannel All Aluminum Condenser Coil, Copper tube/Aluminum fin Evaporator Coil Simplicity® SE Controller including Discharge Air, Return Air, and Outdoor Air Temperature Sensors Return Air Smoke Detector Dry Bulb Economizer (Downflow only) (with Barometric Relief) with Economizer Fault Detection & Diagnostic (Meets ASHRAE 90.1-2013, IECC 2015, California Title 24, AMCA 511) Field Installed Accessories Information is subject to change without notice. Check local codes. Printed 1012812016 0 Q) 0) r� T < t_17 Wni N < r� T Wni N < co 23 6 ww cq 0 K Direct Fit (3-12.5 Ton Page:6 R Package) L526 Single Package R -410A Air Conditioner Project Name: SOLA J— Unit Model #: ZXG08D4B3AA26111A2 Quantity: 3 Tag #: 5 WKS -FACTORY — System ZXG08D4B3AA2B111A2 (3) BLD XX12E Field Installed Accessory Unit Accessory Weights Unit Accessory Weights (lbs.) Vertical Flow Dry Bulb Economizer Small Footprint 63 orizontal Flow Dry Bulb Economizer Small Footprint Short 96 orizontal Flow Dry Bulb Economizer Small Footprint Short 75 orizontal Flow Dry Bulb Economizer Small Footprint Tall 81 lorizontal Flow Dry Bulb Economizer targe Footprint Short 105 -lorizontal Flow Dry Bulb Economizer Large Footprint Tall 102 ower Exhaust Vert Flow Small Footprint — 38— ower Exhaust Vert Flow Large Footprint ower Exhaust Horiz Flow Small Footprint 38 _ 38 ower Exhaust Horiz Flow Large Footprint—' 38 ail Guard Kit Small Short Factory Installed 19 -fail Guard Kit Small Tall Factory Installed -- 24 ail Guard Kit Large Short Factory Installed 50 ail Guard Kit Large Tall Factory Installed 50 Curb Rigid 14" Small Footprint — Curb Rigid Rigid 24" Small Footprint — —� 145 135 .urb Rigid 14" Large Footprint — — J�135 'urb Rigid 24" Large Footprint 135 Unitary Sales Tool v1.5.9.0 Information is subject to change without notice. Check local codes. Printed 10/28/2016 i�YORK Small Sunline (3-6 Ton Package) N543 Single Package -R-410A Air Conditioner Project Name: SOLA - 60 °F � ----_- Quantity: 1 -----^ _—-----A_--_C_ooling_P_e_rf_orman_c_e_—_-_---_---_-_---\ 2.000 CFM Total gross capacity 61.1 MBH Sensible gross capacity 45.4 MBH Total net capacity 57.3 MBH Sensible net capacity 41.6 MBH Seasonal Efficiency (at ARI) 14.00 SEER Efficiency (at ARI) 11.80 I-EIR Ambient DB temp. 95.0 °F Entering DB temp. 80.0 °F Entering WB temp. 67.0 `f- Leaving DB temp. 59.0 °F Leaving WB temp. 57.3 °F Power input (w/o blower) 4.2.8 kW Sound power --- ------------ - - „---82 dBA) Refrigerant Elevation R_efrigeerant type _ _ R-41 OA Gas Heating Performance Electrical Data ----- ---- Entering DB temp. 60 °F Heating output capacity (Max) 100 M13H Supply air 2.000 CFM Heating input capacity (Max) 12.5 M13H Leaving DB temp. 106.3 °F Air temp. rise 46.3 °F SSE 80.6 % Stages -- -- - ---- -- -- 1 - --- - Supply Air Blower Performance Supply air 2000 CFM Ext. static pressure 0.6 IWG Addl. Unit Losses (Options/Accessories) 0.15 IWG Blower speed 1151 RPM Duct location Bottom Motor rating 1.50 HP Actual required BHP 1.19 HP Power input 1,11 kW Elevation 0 ft. Drive type _ — _ ____BELT_ Electrical Data ----- ---- ----- Power supply 460-3-60 ----- Unit min circuit ampacity 14.1 Amps Unit max over -current protection _ _ _ - 20 Amps __ _ Dimensions & Weight _ Hgt 33 in. Len 83 in Wth 45 in. Weight with factory installed options 699 lbs. Clearances Right 24 in. Front 32 in. Back 36 in. To 72 in. Bottom 0 in. Left_ 36 in.__J _ _ Note: Please refer to the tech guide for listed maximum static pressures AMf01CAN� V � Got unitary Sales Tool 0.5.9.0 age: 7 Unit Model #: ZE060H12B4C1EAA1A1 System: ZE060H12B4C1EAA1A1 5 Ton • York Units are Manufactured at an ISO 9001 Registered Facility and Each Rooftop is Completely Computer -Run Tested Prior to Shipment. Unit Features • Single Stage Cooling • Single Stage Coaling • Single Stage Gas Aluminum Steel • 125 MBH Input • Unit Cabinet Constructed of Powder Painted Steel, Certified At 1000 Hours Salt Spray Test (ASTM B-117 Standards) •° Full Perimeter Base Rails with Built in Rigging Capabilities • Either Supply and/or Return can be Field Converted from Vertical to Horizontal Configuration without Cutting Panels. • Scroll Compressor • Dry Bulb Economizer and Hood (No Barometric Relief Damper) with Economizer Fault Detection & Diagnostic (Meets ASHRAE 90.1-2013, IECC 2015, California Title 24, AMCA 511) • 1.5 HP Standard Static Belt Drive Blower • Unit Ships with 1" Throwaway Filters with a Standard Filter Rack That Will Accept up to 2" Filters • Solid Core Liquid Line Filter Driers • Single Point Power Connection • Short Circuit Current: 5kA RMS Symmetrical • Through -the -Curb and Through -The -Base Utility Connections • Return Air Smoke Detector • Microchannel All Aluminum Condenser Coil, Copper tube/Aluminum fin Evaporator Coil • Galvanized Steel Drain Pan • Standard Access Doors Standard Unit Controller: Simplicity Control Board • An Integrated Low -Ambient Control, Anti -Short Cycle Protection, Lead -Lag, Fan On and Fan off Delays, Low Voltage Protection, On -Board Diagnostic and Fault Code Display. Allows all units to operate in the cooling mode down to 0 °F outdoor ambient without additional components or intervention. • Safety Monitoring - Monitors the High and Low -Pressure Switches, the Freezestats, the Gas Valve, if Applicable, and the Temperature Limit Switch on Gas and Electric Heat Units. The Unit Control Board will Alarm on Ignition Failures, Safety Lockouts and Repeated Limit Switch Trips. BAS Controller • Simplicity SL Controller including Discharge Air, Return Air, and Outdoor Air Temperature Sensors Warranty • One (1) Year Limited Warranty on the Complete Unit • Five (5) Year Warranty - Compressors and Electric Heater Elements • len (10) Year Warranty - Aluminized Heat Exchanger Information is subject to change wilhout nett(.(' Check local codes. Printed 10/28/2016 c� Kit 2 "am YO R K ` Project Name: SOLA Quantity: 1 Small Sunline (3-6 Ton T Page:8 Package) N543 Single Package R -410A Air Conditioner --Unit #: Model ZEO60H1264C1EAA1A1 _.el #: - -•---------• A -- - System: ZE0601-112134C1EAAW Factory Installed Options ZE060H12B4C1EAA1A1 Field Installed Accessories 1 RD0410 - Barometric Relief Damper with Hood Kit (Downflow Unit or Duct Mounted) (6.0 lbs) 0 1 RC0434 - Roof Curb - 14" High, Flat, Uninsulated, Full Perimeter (Shipped Knocked Down) (86.0 lbs) Unitary Sales lool v1.5 9.0 Information is sublect to change without nolice, Check local codes. Printed 1 012 812 0 1 6 I York Small Sunline Single Packaged R-41 OA Air Product Category: ZE Conditioner 11.8 EER / 14.0 SEER 060 Nominal Cooling Capacity: Single Stage Cooling 5 Ton Heat Type and Nominal Heat Capacity: Single Stage Gas Aluminum Steel 125 MBH Input H12 B Airflow Options: 1.5 HP Standard Static Belt Drive Blower Voltage: 460-3-60 4 Dry Bulb Economizer and Hood (No Barometric Relief Economizer I Damper: C Damper) with Economizer Fault Detection & Diagnostic (Meets ASHRAE 90.1-2013, IECC 2015, California Title 24, AMCA 511) Sensor Options: E Return Air Smoke Detector Controls: Simplicity® SE Controller including Discharge Air, Return Air, and Outdoor Air Temperature Sensors A A Refrigeration: Microchannel All Aluminum Condenser Coil, Copper tube/Aluminum fin Evaporator Coil Additional Options: 1 1" Throwaway Filters A Cabinet Options: Galvanized Steel Drain Pan Standard Access Doors Product Generation: 1 Field Installed Accessories 1 RD0410 - Barometric Relief Damper with Hood Kit (Downflow Unit or Duct Mounted) (6.0 lbs) 0 1 RC0434 - Roof Curb - 14" High, Flat, Uninsulated, Full Perimeter (Shipped Knocked Down) (86.0 lbs) Unitary Sales lool v1.5 9.0 Information is sublect to change without nolice, Check local codes. Printed 1 012 812 0 1 6 IM Lo Z V O I � C A O Q Q 'C Y �✓ R a. I'y�wJ ' I � cY I I I a al a M oo• I ._. I � 1 I ry m .. V w m` m• LU 14 O .� v V' ✓, a0 V �n .0 .n n ap ap .p ,n in an r 't m m O N N o ' a N C O I ' O O I. N N 4) •-, .-, .y . � ., r � r. ., , 1 . 1 , . , , , . 'O V) F -O V ti m I I H L IM Lo Z V O I � C A O Q Q 'C Y �✓ R a. I'y�wJ ' I I I � cY I I I M M M rvry �� O M oo• I ._. I � 1 I ry m .. V .o m` m• i 14 O .� v V' ✓, a0 V �n .0 .n n ap ap .p ,n in an �!j N J � O O o ' a N , I. •-, .-, .y . � ., r � r. ., , 1 . 1 , . , , , . 00 F -O V ti m O - - H M n m .. .-, _ - gym' MV .- -, _—._ _• I � I I � cY I I I M M M rvry �� O M oo• I ._. I � 1 I ry m .. V li i 14 O .� v V' ✓, a0 V �n .0 .n n ap ap .p ,n in an �!j N J � O O o ' a N , I I � cY I I I rvry �� M oo• I ._. I � 1 I ry m .. V li VU 1 Q m ,ri •��. �,. .. , � - I I I L7 Q 'ins f.' m Q . To'. m i ry n V m> (3 3 3 , U I � QCJ ✓, 1-U vKJ_ I NN rin'ln >f I ., Z �. iil ..iQ-�QVNi rvtiV .. pan pan .1, .n000J v, r / yt I -� I � >o`mmcnv N v,zr- a.na.nrvryrvma>-n.n .�-a o.Qi,c• Z3 "I o v, f a c cjm Jns i o - X 46 O ro O m V 9 O C Z O � li i 14 m Fin I t_ z � Z w O o , O a m K Project Name: SOLA Quantitv: 1 Small Sunifine (3-6 Ton Package) N543 Single Package R -410A Air Conditioner Unit Model # System Typical Application Page- 10 ZE0601-1112134C11EAAW ZE060H12B4C1EAA1A1 FIELD -SUPPLIED DISCONNECT SWITCH I TO WN I HOL VVNINU POWER TO INDOOR SUPPLY THERMOSTAT Unitary Sales Tool v1S.9,0 RETURN AIR DUC11, Information is subject to change w0hout notice. Check local codes. TO GAS SUPPLY LINE N Printed 10128/2016 MYORKSmall Sunfine (3-6 Ton Page: 11 �' Package) N543 Single Package R -410A Air Conditioner Project Name: SOLA Unit Model #: ZE060H12I34&1EAA1A1 Quantity: 1 System: ZE0601­112134C1EAMA1 Typical Field Power and Control Wiring TYPICAL POWER WIRING LUG REFER ELECTRiCA1. DATA TABLES TO SIZE THE DISCONNECT SWITCH OVIRCURRENT PROTECTION ANDA'IRING CONTACTOR FIELD -SUPPLIED DISCONNECT L -----------i- I C} - r- THREE L------------I--Q.^¢_ PHASE GROUND L - - - - - - - - - - - - - - - J_ -a LUG O__ > POWER L SUPPLY TYPICAL COOL/HEAT CONTROL WIRING COOLING ONLY (24 VOLT THERMOSTAT) COOLING / HEATING (24 VOLT THERMOSTAT) THERMOSTAT' UNIT TERMINAL THERMOSTAT' TERMINALS STRIP T61 TERMINALS UNIT TERMINAL ISH STRIP STRIP TBI 24 VOLT ADD C .. ............... TRANSFORMER JUMPER .. ......... .... .. U12' C ) - -------------- -- 24 VOLT TRANSFORMER ccn,) . . ................ _0 C, (AD - -------------- -110, '24 VOLT THERMOSTAT TO CONTROL Ot,! ECOMIZER ON SECOND 0- S FACE COOLING USE A 2 STAGE COOLING THEIRNIOSTAT @ I COOLING / HEATING (ELECTRONIC THERMOSTAT) MULTI STAGE THERMOSTA I TERMINALS UNIT TERMINAL ADD RC STRIP TE11 21 VOLT JUMPER PH --------------------- R TRANSFORMER Y1-----------------­-- Y1 Y2 ---------- 2 ------- Y2 Vy 1 ......... ­­ ...... W 1 4 1V2 -'_-----'3 ------- N2 LEDI --------------------- LF D 2 NOT - ------------ SED 4 ADD Al JUMPER A2 TO RENIO T E SENSOR il IF USED ELECTRON:C PROGrANIMABLE THERN4j°7AI TYF CAL SECOND STAGE COOLING S NOT REOU PEP ON UN IS LES` E-­,QNOf.I 'Ff,, SECOND STAGE HEA1:NG S ONLY RLOU PEE) tUN I IN T, V, IH A Pv),;Q!,]A,,;E ELECTR C HEATER -')R: STA,",E GA:z HEAT • REMOVE JUMPER J2 FROMTERMINALS 4 AND C; ON JI PLUG CONNECTOR PC ON UNITS WITH ECONOM..ZER TERN'INALS A] AND A2 PROVIDE A RELAY OUTPUT TO CLOSE THE OUTDOOR ECONOMIZER DAMPERS WHEN THE I .HE RISIAI TO THE SEI -BACK POSI I ION 24 VOLT TH.ERNIOSTAT Tn CONTROL TrE ECONOMIZER ON THE SECOND STAGE" COCILINC, OR TO eAVE AN ELECTRIC HEAT ACCESSORY VvtTH Tv,,O 5TAC;_:S0"-,7_Af jSF A 2 STAGE COOL AND HEAT THERMOSTAT COOLING I HEATING (ELECTRONIC THERMOSTAT) SINGLE STAGE THERMOSTAT. TERMINALS UNIT TERMINAL RH STRIP TB1 ADD- -------- -1 ...... Yi JUMPER ............... GG --------------- -- - - 24 VOLT TRANSFORMER 'ELEC'r.ON C PROGRAMWV+BLE THERMOSTAT TYPICAL To CONTROL THE ECONOKAiZER ON STAGE COOLING USE A2 STAGE COOL AND HEAT THERN10SlAT Unitary sales Idol v1.b.9.0 Information is subject to change without notice Check local codes Printed 10/28/2016 CONTACTOR PIE D SUPPLIED 7a DISCONNECT , r-- _- :' ' I SINGLE II = — - - - - - - - - -----------------Cr"- - - - - C, - -:_ _0- - PHASE POWER GROUND L _ SUPPLY LUG REFER ELECTRiCA1. DATA TABLES TO SIZE THE DISCONNECT SWITCH OVIRCURRENT PROTECTION ANDA'IRING CONTACTOR FIELD -SUPPLIED DISCONNECT L -----------i- I C} - r- THREE L------------I--Q.^¢_ PHASE GROUND L - - - - - - - - - - - - - - - J_ -a LUG O__ > POWER L SUPPLY TYPICAL COOL/HEAT CONTROL WIRING COOLING ONLY (24 VOLT THERMOSTAT) COOLING / HEATING (24 VOLT THERMOSTAT) THERMOSTAT' UNIT TERMINAL THERMOSTAT' TERMINALS STRIP T61 TERMINALS UNIT TERMINAL ISH STRIP STRIP TBI 24 VOLT ADD C .. ............... TRANSFORMER JUMPER .. ......... .... .. U12' C ) - -------------- -- 24 VOLT TRANSFORMER ccn,) . . ................ _0 C, (AD - -------------- -110, '24 VOLT THERMOSTAT TO CONTROL Ot,! ECOMIZER ON SECOND 0- S FACE COOLING USE A 2 STAGE COOLING THEIRNIOSTAT @ I COOLING / HEATING (ELECTRONIC THERMOSTAT) MULTI STAGE THERMOSTA I TERMINALS UNIT TERMINAL ADD RC STRIP TE11 21 VOLT JUMPER PH --------------------- R TRANSFORMER Y1-----------------­-- Y1 Y2 ---------- 2 ------- Y2 Vy 1 ......... ­­ ...... W 1 4 1V2 -'_-----'3 ------- N2 LEDI --------------------- LF D 2 NOT - ------------ SED 4 ADD Al JUMPER A2 TO RENIO T E SENSOR il IF USED ELECTRON:C PROGrANIMABLE THERN4j°7AI TYF CAL SECOND STAGE COOLING S NOT REOU PEP ON UN IS LES` E-­,QNOf.I 'Ff,, SECOND STAGE HEA1:NG S ONLY RLOU PEE) tUN I IN T, V, IH A Pv),;Q!,]A,,;E ELECTR C HEATER -')R: STA,",E GA:z HEAT • REMOVE JUMPER J2 FROMTERMINALS 4 AND C; ON JI PLUG CONNECTOR PC ON UNITS WITH ECONOM..ZER TERN'INALS A] AND A2 PROVIDE A RELAY OUTPUT TO CLOSE THE OUTDOOR ECONOMIZER DAMPERS WHEN THE I .HE RISIAI TO THE SEI -BACK POSI I ION 24 VOLT TH.ERNIOSTAT Tn CONTROL TrE ECONOMIZER ON THE SECOND STAGE" COCILINC, OR TO eAVE AN ELECTRIC HEAT ACCESSORY VvtTH Tv,,O 5TAC;_:S0"-,7_Af jSF A 2 STAGE COOL AND HEAT THERMOSTAT COOLING I HEATING (ELECTRONIC THERMOSTAT) SINGLE STAGE THERMOSTAT. TERMINALS UNIT TERMINAL RH STRIP TB1 ADD- -------- -1 ...... Yi JUMPER ............... GG --------------- -- - - 24 VOLT TRANSFORMER 'ELEC'r.ON C PROGRAMWV+BLE THERMOSTAT TYPICAL To CONTROL THE ECONOKAiZER ON STAGE COOLING USE A2 STAGE COOL AND HEAT THERN10SlAT Unitary sales Idol v1.b.9.0 Information is subject to change without notice Check local codes Printed 10/28/2016 Small Sunline (3-6 Ton Page: 12 YO R K Package) N543 Single Package R -410A Air Conditioner Project Name: SOLA _ Unit Model #: ZE060H12B4C1EAA1A1 Quantity: 1 System: ZE060H12B4C1EAA1A1 2"TYP � COMPRESSOR DUCT SUPPORT AND CONDENSER BACK RAILS / END OF UNIT OF UNIT \ SUPPLY'' AIR /— \\\ r/ t 14 RETURN' AIR 19-112-- 37-1/4" 9-112"37-114 DUCT SIZES: Supply Air = 19" x 19" Return Air = 19" x, 19" Unitary Sales Tool 0.5.9.0 ��\•;�\X� '19-112„ /rte 4-112"� FRONT OF UNIT - Supply and Return Air (including duct support rails) Shown are typical for bottom duct applications. For location of horizontal duct applications (on back of units, refer to Unit Dimensions details. 1RC0414 Rent Curb Dimensions Information is sublecl to change without notice. Check locel codes. Printed 10/28/2016 Date 10/28/2016 Project Name SOLA Project Number NN10281606 Client / Purchaser PRECISE-LAMAR Guide Specification Summary Page Product Series Models and Unit Tags Direct Fit (3-12.5 Ton Package) L526 ZXG08D4B3AA2B111A2 5 WKS -FACTORY BLD Small Sunline (3-6 Ton Package) N543 ZE060H12B4C1EAA1A1 Unitary Sales Tool v1.5, 9.0 Information is subject to change without notice Check local codes Printed 10/28/2016 -----�-�—�------------- �-----Guide Specification for -- Ibb do MYORK Direct Fit DIVISION 23 — HEATING, VENTILATING, AND AIR-CONDITIONING(HVAC)� !3 00 00 HEATING VENTILATING, AND AIR-CONDITIONING(HVAC) 23 06 00 Schedules for HVAC 23 06 80 Schedules for Decentralized HVAC Equipment 23 06 80. 13 Decentralized Unitary HVAC Equipment Schedule 23 06 80. 13.A Rooftop unit schedule 23 07 00 HVAC Insulation 23 07 16 HVAC Equipment Insulation Page: 14 23 07 16. 13 Decentralized, Rooftop Units 23 07 16. 13.A Evaporator fan compartment 1. Interior cabinet surfaces shall be insulated with a minimum 1/2- in. thick, minimum 1 1/2 Ib density, flexible fiberglass insulation bonded with a phenolic binder, neoprene coated on the air side. 2. Insulation and adhesive shall meet NFPA 90A requirements for flame spread and smoke generation. 23 07 16. 13.13 Gas heat compartment 1. Aluminum foil -faced fiberglass insulation shall be used. 2. Insulation and adhesive shall meet NFPA 90A requirements for flame spread and smoke generation. 23 09 00 Instrumentation and Control for HVAC 23 09 13. 23 Sensors and Transmitters 23 09 13. 23.A Thermostats 1. Thermostat must: a. energize "G when calling for fan only or continuous fan. b. have capability to energize 2 different stages of cooling.. and 2 different stages of heating. c. include capability for occupancy scheduling. 23 09 23 Direct -digital Control system for HVAC 23 09 23, 13 Decentralized, Rooftop Units 23 09 23. 13.A Simplicity SE (Unit based microprocessor control) 1. Shall be ASHRAE 62-2001 compliant. 2. Shall include an integrated economizer controller to support an economizer with 4 to 20 mA actuator input. 3. Controller shall accept the following inputs: space temperature, setpoint adjustment, outdoor air temperature, indoor air quality, outdoor air quality, indoor relative humidity, compressor lockout, fire shutdown, enthalpy, fan status, remote time clock/door switch. 4. Shall accept a CO2 sensor in the conditioned space, and be Demand Control Ventilation ready. 5. Unit shall provide surge protection for the controller through a circuit breaker. 6. Shall have an LED display independently showing the status of activity on the communication bus, and processor operation. 7. Software upgrades will be accomplished by local download. Software upgrades through chip replacements are not allowed. Guide Specification for M'Q�-J=YORK Direct Fit Page: 15 A. Unit shall be complete with self-contained low -voltage control circuit protected by a resettable circuit breaker on the 24 -volt transformer side. B. Unit shall incorporate a lockout circuit which provides reset capability at the space thermostat or base unit should any of the following standard safety devices trip and shut off compressor: C. Loss-of-charge/Low-pressureswitch. D. High-pressure switch. E. Freeze -protection thermostat, evaporator coil. If any of the above safety devices trip, an LED (light -emitting diode) indicator shall flash a diagnostic code that indicates which safety switch has tripped. F. Unit shall incorporate "AUTO RESET' compressor over temperature, over current protection. G. Unit shall operate with conventional thermostat designs and have a low voltage terminal strip for easy hook-up. H. Unit control board shall have on -board diagnostics and fault code display. I. Standard controls shall include anti -short cycle and low voltage protection, and permit cooling operation down to 0 °F. J. Control board shall monitor each refrigerant safety switch independently. K. Control board shall retain last 5 fault codes in non-volatile memory, which will not be lost in the event of a power loss. 23 09 23. 13.13 RTU Open -multi -protocol, direct digital controller 1. Shall be ASHRAE 62-2001 compliant. 2. Shall include built-in protocol for BACNET , Modbus , and Johnson N2. 3. Shall allow access of up to 62 network variables (SNVT). Shall be compatible with all open controllers 4. Baud rate Controller shall be selectable using a dipswitch. 5. Shall have an LED display independently showing the status of serial communication, running, errors, power, all digital outputs, and all analog inputs. 6. Shall accept the following inputs: space temperature, setpoint adjustment, outdoor air temperature, indoor air quality, outdoor air quality, compressor lock- out, fire shutdown, enthalpy switch, and fan status/filter status/ humidity/ remote occupancy. 7. Software upgrades will be accomplished by either local or remote download. No software upgrades through chip replacements are allowed. 23 09 33 Electric and Electronic Control System for HVAC 23 09 33. 13 Decentralized, Rooftop Units 23 09 33. 13.A General 1. Shall be complete with self- contained low- voltage control circuit protected by a resettable circuit breaker on the 24-v transformer side. Transformer shall have 75VA capability. 2. Shall utilize color -coded wiring. 3. Shall include a central control terminal board to conveniently and safely provide connection points for vital control functions such as: smoke detectors, phase monitor, gas controller, economizer, thermostat, DDC control options, and low and high pressure switches. 4. The heat exchanger shall be controlled by an integrated gas controller (IGC) microprocessor. See heat exchanger section of this specification. 23 09 33. 23.13 Safeties 1. Compressor over -temperature, over -current. High internal pressure differential. 2. Low-pressure switch. a. Units with 2 compressors shall have different sized connectors for the circuit 1 and circuit 2 low and high pressure switches. They shall physically prevent the cross- wiring of the safety switches between circuits 1 and 2. b. Low pressure switch shall use different color wire than the high pressure switch. The purpose is to assist the installer and service technician to correctly wire and or troubleshoot the rooftop unit. 3. High pressure switch. a. Units with 2 compressors shall have different sized connectors for the circuit 1 and circuit 2 low and high pressure switches. They shall physically prevent the cross -wiring of the safety switches between circuits 1 and 2. MYORK Guide Specification for Direct Fit rel Page: 16 High pressure switch shall use different color wire than the low pressure switch. The purpose is to assist the installer and service technician to correctly wire and or troubleshoot the rooftop unit. 4. Automatic reset,/motor thermal overload protector. 5. Heating section shall be provided with the following minimum protections: a. High-temperature limit switches. b. Induced draft motor speed sensor. c. Flame rollout switch. d. Flame proving controls 23 09 93 Sequence of Operations for HVAC Controls 23 09 93. 13 Decentralized, Rooftop Units 23 09 93. 13 INSERT SEQUENCE OF OPERATION 23 40 13 Panel Air Filters 23 40 13. 13 Decentralized, Rooftop Units 23 40 13. 13.A Standard filter section 1. Shall consist of factory -installed, low velocity, disposable 2" thick fiberglass filters of commercially available sizes. 2. Units can accept 2" or 4" filters and have a field convertible toolless 3. Filters shall be accessible through an access panel with toolless removal as described in the unit cabinet section of this specification (23 81 19.13.1-1). 23 81 19 Self -Contained Air Conditioners 23 81 19. 13 Small -Capacity Self -Contained Air Conditioners 23 81 19. 13.A General 1. Outdoor, rooftop mounted, electrically controlled, heating and cooling unit utilizing a fully hermetic scroll compressor(s) for cooling dutyand gas combustion for heating duty. 2. Factory assembled, single -piece heating and cooling rooftop unit. Contained within the unit enclosure shall be all factory wiring, piping, controls, and special features required prior to field start-up. 3. Unit shall use environmentally sound, R-41 OA refrigerant. 4. Unit shall be installed in accordance with the manufacturer's instructions. 5. Unit must be selected and installed in compliance with local, state, and federal codes. 23 81 19. 13.13 Quality Assurance 1. Unit meets ASHRAE 90.1 minimum efficiency requirements. 3. Unit shall be rated in accordance with AHRI Standards 210/2.40 and 340/360. 4. Unit shall be designed to conform to ASHRAE 15, 2001. 5. Unit shall be UL -tested and certified in accordance with ANSI Z21.47 Standards and UL -listed and certified under Canadian standards as a total package for safety requirements. 6. Insulation and adhesive shall meet NFPA 90A requirements for flame spread and smoke generation. 7. Unit casing shall be capable of withstanding 1000 -hour salt spray exposure per ASTM B117 (scribed specimen). 8. Unit shall be designed in accordance with ISO 9001, and shall be manufactured in a facility registered by; ISO 9001. 9. Roof curb shall be designed to conform to NRCA Standards. 10. Unit shall be subjected to a completely automated run test on the assembly line. The data for each unit; will be stored at the factory, and must be available upon request. 11. Unit shall be designed in accordance with UL Standard 1995, including tested to withstand rain. 12. Unit shake tested to assurance level 1, ASTM D4169 to ensure shipping reliability. 13. High Efficient Motors listed shall meet section 313 of the Energy Independence and Security Act of 2007; (EISA 2007). i�YORK 23 81 23 81 23 81 3. 4. 5. 6. 23 81 Guide Specification for Direct Fit Pager 17 19. 133 Delivery, Storage, and Handling Unit shall be stored and handled per manufacturer's recommendations. 19. 13.E Project Conditions As specified in the contract. 19. 13.F Operating Characteristics Unit shall be capable of starting and running at 125°F (52°C)ambient outdoor temperature, meeting maximum load criteria of AHRI Standard 2.10/240 or 340/360 at ± 10% voltage. Compressor with standard controls shall be capable of operation down to 0°F (2°C), ambient outdoor temperatures. See below for head pressure control package or winter start kit. Unit shall discharge supply air vertically or horizontally as shown on contract drawings. Unit shall be factory configured for vertical supply & return configurations. Unit shall be field convertible from vertical to horizontal airflow on all models. Unit shall be capable of mixed operation: vertical supply with horizontal return or horizontal supply with vertical return. 19. 13.G Electrical Requirements 1. Main power supply voltage, phase, and frequency must match those required by the manufacturer. 23 81 19. 13.H Unit Cabinet 1. Unit cabinet shall be constructed of galvanized steel with exterior surfaces coated with a non -chalking, powder paint finish, certified at 1000 hour salt spray test per ASTM -6117 standards. 2. Evaporator fan compartment interior cabinet insulation shall conform to AHRI Standards 210/240 or 340/360 minimum exterior sweat criteria. Interior surfaces shall be insulated with a minimum 1/2- in. thick, 1 Ib density, flexible fiberglass insulation, neoprene coated on the air side. Aluminum foil- faced fiberglass insulation shall be used in the gas heat compartment. Fan shall be a belt drive assembly and include an adjustable pitch motor pulley. Fan wheel shall be double inlet type with forward curve blades, dynamically balanced to operate smoothly throughout the entire range of operation. Airflow design shall be constant volume. Bearings shall be sealed and permanently lubricated for longer life and no maintenance. Entire blower assembly and motor shall be slide out design. 3. Condenser Fan Assembly: The outdoor fans shall be of the direct drive type, discharge air vertically, have aluminum blades riveted to corrosion resistant steel spider brackets and shall be dynamically balanced for smooth operation. The outdoor fan motors shall have permanently lubricated bearings internally protected against overload conditions and staged independently. A cleaning window shall be provided on two sides of the units for coil cleaning. 4. Base of unit shall have a minimum of four locations for thru-the-base gas and electrical connections (factory installed or field installed), standard. 5. Base Rail a. Unit shall have base rails on a minimum of 4 sides. b. Holes shall be provided in the base rails for rigging shackles to facilitate maneuvering and overhead rigging. c. Holes shall be provided in the base rail for moving the rooftop by fork truck.. d. Base rail shall be a minimum of 16 gauge thickness. 6. Condensate pan and connections a. Shall be an internally sloped condensate drain pan made of a non -corrosive material. b. Shall comply with ASHRAE Standard 62. c. Shall use a 3/4" - 14 NPT drain connection, possible either through the bottom or side of the drain pan. Connection shall be made per manufacturer's recommendations. 7. Top panel a. Shall be a single piece top panel. 8. Gas Connections a. All gas piping connecting to unit gas valve shall enter the unit cabinet at a single location on side of unit b. Thru-the-base capability (1.) Standard unit shall have a thru-the-base gas- line location using a raised, embossed portion of the unit basepan. (2.) Optional, factory- approved, water- tight connection method must be used for thru-the-base gas connections. (3.) No basepan penetration, other than those authorized by the manufacturer, is permitted. Kilj�YORK 9. Electrical Connections Guide Specification for Direct Fit Page: 18 a. All unit power wiring shall enter unit cabinet at a single, factory -prepared, knockout location. b. Thru-the-base capability. (1.) Standard unit shall have a thru-the-base electrical location(s) using a raised, embossed portion of the unit basepan. (2.) Optional, factory- approved, water -tight connection method must be used for thru-the-base electrical connections. (3.) No basepan penetration, other than those authorized by the manufacturer, is permitted. 10. Component access panels (standard) a. Cabinet panels shall be easily removable for servicing. b. Unit shall have one factory installed, toolless, removable, filter access panel. c. Panels covering control box, indoor fan, indoor fan motor, gas components(where applicable), and compressors shall have a molded composite handles. d. Handles shall be UV modified, composite. They shall be permanently attached, and recessed into the panel. e. Screws on the vertical portion of all removable access panel shall engage into heat resistant, molded composite collars. f. Collars shall be removable and easily replaceable using manufacturer recommended parts. 23 81 19. 13.1 Gas Heat 1. General a. Heat exchanger shall be an induced draft design. Positive pressure heat exchanger designs shall not be allowed. b. Shall incorporate a direct- spark ignition system and redundant main gas valve. c. Gas supply pressure at the inlet to the rooftop unit gas valve must match that required by the manufacturer. 2. The heat exchanger shall be controlled by an integrated gas controller (IGC) microprocessor. a. IGC board shall notify users of fault using an LED (light-ernitting diode). b. The LED shall be visible without removing the control box access panel. c. IGC board shall contain algorithms that modify evaporator -fan operation to prevent future cycling on high temperature limit switch. d. Unit shall be equipped with anti -cycle protection with one short cycle on unit flame rollout switch or 4 continuous short cycles on the high temperature limit switch. Fault indication shall be made using an LED. 3. Standard Heat Exchanger construction a. Heat exchanger shall be of the tubular -section type constructed of a minimum of 20 -gauge steel coated with a nominal 1.2 mil aluminum -silicone alloy for corrosion resistance. b. Burners shall be of the in -shot type constructed of aluminum -coated steel. c. Burners shall incorporate orifices for rated heat output up to 2000 ft (610m) elevation. Additional accessory kits may be required for applications above 2000 ft (610m) elevation, depending on local gas supply conditions. d. Each heat exchanger tube shall contain multiple dimples for increased heating effectiveness. 6. Induced draft combustion motor and blower a. Shall be a direct -drive, single inlet, forward -curved centrifugal type. b. Shall be made from steel with a corrosion -resistant finish. c. Shall have permanently lubricated sealed bearings. d. Shall have inherent thermal overload protection. e. Shall have an automatic reset feature. 23 81 19. 13.J Coils 1. Standard Aluminum Fin/Copper Tube Coils a. Standard evaporator and condenser coils shall have aluminum lanced plate fins mechanically bonded to seamless internally grooved copper tubes with all joints brazed. b. Evaporator coils shall be leak tested to 150 prig, pressure tested to 450 psig, and qualified to UL. 1995 burst test at 1775 psig. c. Condenser coils shall be leak tested to 150 psig, pressure tested to 650 psig, and qualified to UL 1995 burst test at 1980 psig. Guide Specification forMYORK' Page: 19 Direct Fit 23 81 19. 13.K Refrigerant Components 1. Refrigerant circuit shall include the following control, safety, and maintenance features a. 'Thermostatic Expansion Valve (TXV) shall help provide optimum performance across the entire operating range. Shall contain removable power element to allow change out of power element and bulb without removing the valve body.(Orifice on 3-5 Ton Units) b. Refrigerant filter drier - Solid core design. c. Service gauge connections on suction and discharge lines. d. Pressure gauge access through a specially designed access port in the top panel of the unit. 2. There shall be gauge line access port in the skin of the rooftop, covered by a black, removable plug. a. The plug shall be easy to remove and replace. b. When the plug is removed, the gauge access port shall enable maintenance personnel to route their pressure gauge lines. c. This gauge access port shall facilitate correct and accurate condenser pressure readings by enabling the reading with the compressor access panel on. d. The plug shall be made of a leak proof, UV- resistant, composite material. 3. Compressors a. Unit shall use fully hermetic, scroll compressor for each independent refrigeration circuit. b. Compressor motors shall be cooled by refrigerant gas passing through motor windings. c. Compressors shall be internally protected from high discharge temperature conditions. d. Compressors shall be protected from an over -temperature and over -amperage conditions by an internal, motor overload device. e. Compressor shall be factory mounted on rubber grommets. f. Compressor motors shall have internal line break thermal, current overload and high pressure differential protection. g. Crankcase heaters shall not be required for normal operating range, unless provided by the factory. 23 81 19. 131 Filter Section 1. Filters access is specified in the unit cabinet section of this specification. 2. Shall consist of factory -installed, low velocity, throw -away 2" thick fiberglass filters. 3. Units can accept 2" or 4" filters and have a field convertible toolless 23 81 19. 13.M Evaporator Fan and Motor 1. Evaporator fan motor a. Shall have permanently lubricated bearings. b. Shall have inherent automatic -reset thermal overload protection or circuit breaker. 3. Belt -driven Evaporator Fan a. Belt drive shall include an adjustable -pitch motor pulley. b. Shall use sealed, permanently lubricated ball-bearing type. c. Blower fan shall be double -inlet type with forward -curved blades. d. Shall be constructed from steel with a corrosion resistant finish and dynamically balanced. 23 81 19. 13.N Condenser Fans and Motors The outdoor fans shall be of the direct drive type, discharge air vertically, have aluminum blades riveted to corrosion resistant steel spider brackets and shall be dynamically balanced for smooth operation. The outdoor fan motors shall have permanently lubricated bearings internally protected against overload conditions and staged independently. A cleaning window shall be provided on two sides of the units for coil cleaning. 1. Condenser fan motors a. Shall be a totally enclosed motor. b. Shall use permanently lubricated bearings. c. Shall have inherent thermal overload protection with an automatic reset feature. d. All models shall use a shaft -down design except shaft -up on ZX14 & ZY12 size with rain shield. 2. Condenser Fans YORK 4910 2 3 Guide Specification for Direct Fit a. Shall be a direct -driven propeller type fan. b. Shall have aluminum blades riveted to corrosion -resistant steel spiders and shall be dynamically balanced. 19. 13.0 Special Features Options and Accessories IntelliSpeed-Staged Air Volume System (ZX12, ZX14, &ZY12) a. Evaporator fan motor: Page: 20 (1.) Shall have permanently lubricated bearings. (2.) Shall have a maximum continuous bhp rating for continuous duty operation; no safety factors above that rating. (3.) Shall be Variable Frequency duty and 2 -speed control. (4.) Shall contain motor shaft grounding ring to prevent electrical bearing fluting damage by safely diverting harmful shaft voltages and bearing currents to ground. Variable Frequency Drive (VFD). Only available on 2 -speed indoor fan motor option (IntelliSpeed) INSERT MITSUBISHI DRIVE SPECIFICATIONS Standard Integrated Economizers: a. Integrated, gear -driven opposing modulating blade design type capable of simultaneous economizer and compressor operation. b. Independent modules for vertical or horizontal return configurations shall be available. Vertical return modules shall be available as a factory installed option. c. Damper blades shall be galvanized steel with composite gears. Plastic or composite blades on intake or return shall not be acceptable. d. Shall include all hardware and controls to provide free cooling with outdoor air when temperature and/or humidity are below setpoints. e. Shall be equipped with gear driven dampers for both the outdoor ventilation air and the return air for positive air stream control. f. Standard models shall be equipped with low- leakage dampers, not to exceed 2% leakage at 1 in. wg pres- sure differential. Economizers will come with Actuator and module that is tied to Simplicity SE (1.) Combined minimum and DCV maximum damper position potentiometers with compressor staging re-lay. (2.) Functions with solid state analog enthalpy or dry bulb changeover control sensing. (3.) Contain LED indicates for:when free cooling is availablewhen module is in DCV mode when exhaust fan contact is closed 14. Return Air Enthalpy Sensor: a. The return air enthalpy sensor shall be used in conjunction with an outdoor air enthalpy sensor to provide differential enthalpy control. 11KW"`Y0RKL` GENERAL Guide Specification for York Sunline Units shall be manufactured by Johnson Controls Unitary Products in an ISO 9001 certified facility. York Sunline units are convertible single package units. Although the units are primarily designed for curb mounting on a roof, they can also be slab -mounted at ground level or set on steel beams above a finished roof. Cooling only, cooling with gas heat and cooling with electric heat models are available with a wide variety of factory -mounted options and field -installed accessories to make them suitable for i almost every application. All units are self-contained and assembled on full perimeter base rails with holes in the four corners for overhead rigging. Every unit is completely piped, wired, charged and tested at the factory to simplify the field installation and to provide years of dependable operation. All models (including those with an economizer) are suitable for either bottom or horizontal duct connections. Models with power I exhaust are suitable for bottom duct connections only. For bottom duct, remove the sheet metal panels from the supply and return air openings through the base of the unit. For horizontal duct, remove the supply and return air panels on the rear of the unit. All non -Scroll compressors include crankcase heaters and all compressors have internal pressure relief. Every refrigerant circuit includes a liquid line filter -drier, a 1 discharge line high pressure switch and a suction line with a freezestat and low pressure/loss of charge switch. The unit control circuit includes a 75 VA transformer, a 24 -volt circuit breaker and a relay board with a compressor lockout circuit, a terminal strip for thermostat wiring, plus an additional set of pin connectors to simplify the interface of additional field controls. All models are CSA listed. All models include a 1 -year limited warranty on the complete unit. Compressors and electric heater elements carry a 5 - year warranty. Aluminized steel and Stainless steel tubular heat exchangers carry a 10 -year warranty. DESCRIPTION Units shall be factory -assembled, single packaged, Electric Cooling/Gas Heat, Electric Cooling/Optional Electric Heat, Heat Pump/Optional Electric Heat are designed for outdoor mounted installation. The 3 ton, 4 ton and 5 ton units shall have minimum SEER rating of 13.0 with heat pumps having a 7.7 H.S.P.F. The 6 Ton Cooling only or Cooling with Electric Heat shall have 11.2 EER, 6 Fon Cooling with Gas Heat shall have 11.0 EER. They shall have built-in field convertible duct connections for down discharge supply/return or horizontal discharge supply/return, and be available with factory installed options or field installed accessories. The units shall be factory wired, piped, charged with R -410A refrigerant and factory tested prior to shipment. All unit wiring shall be both numbered and color coded. All units the cooling performance shall be rated in accordance with Page: DOE and AHRI test procedures. Units shall be CSA listec classified to ANSI Z21.47, UL 1995/CSA No. 236 standards. UNIT CABINET Unit cabinet shall be constructed of galvanized steel, wO exterior surfaces coated with a non -chalking, powdered paint finish, certified at 1000 hours salt spray test per ASTMB117 standards. Indoor blower section shall be insulated with a minimum 1/2" thick insulation, coated on the airside. Aluminum foil faced insulation shall be used i the furnace compartment and be fastened with ridged fasteners to prevent insulation from entering the air stream. Cabinet panels shall be "large" size, easily removable for servicing and maintenance. Full perimeter base rails shall be provided to assure reliable transit of equipment, overhead rigging and proper sealing on roof curb applications. Disposable 1" filters shall be furnished and be accessible through a removable access door, sealed airtight. Units filter track shall be designed to accommodate either 1" or 2" filters. Fan performance measuring ports shall be provided on the outside of the cabinet to allow accurate air measurements of evaporate, fan performance without removing panels or creating air by-pass of the coils. Condensate pan shall be internally sloped and conform to ASHRAE 62-89 self -draining standards. Condensate connection shall be a minimum e 3/4" I.D. female and be a ridged mount connection. INDOOR (EVAPORATOR) FAN ASSEMBLY The indoor fan shall be a factory installed direct -drive or belt -drive assembly that includes an adjustable pitch mot pulley. Job site selected (B.H.P.) brake horsepower shall not exceed the motors nameplate horsepower rating, plu the service factor. Units shall be designed not to operate above service factor. Fan wheel shall be double -inlet typ( with forward -curved blades, dynamically balanced to operate smoothly throughout the entire range of operatic, Airflow design shall be constant air volume. Bearings she be sealed and permanently lubricated for longer life and no maintenance OUTDOOR (CONDENSER) FAN ASSEMBLY The outdoor fan shall be of the direct -driven propeller typ discharge air vertically, have aluminum blades riveted to corrosion resistant steel spider bracket and shall be dynamically balanced for smooth operation. The outdoor fan motor shall be totally enclosed with permanently lubricated bearings, internally protected against overload conditions and staged independently. I Unitary Sales Fool v1.ty 9 0 s %"OjeGI to chinge mlhoul nw,( e Check local .;odes Printed 10128/2016 Guide Specification for Page: 22 6092"YORK York Sunline REFRIGERANT COMPONENTS f. Unit shall incorporate "AUTO RESET' compressor Compressors: over temperature, over current protection. a. Shall be internally protected with internal high- g. Unit shall operate with conventional thermostat pressure relief and over temperature protection. designs and have a low voltage terminal strip for b. Shall have internal spring isolation and sound easy hook-up. muffling to minimize vibration and noise, and be h. Unit control board shall have on-board diagnostics externally isolated on a dedicated, independent and fault code display. mounting. i. Standard controls shall include anti-short cycle and Coils: low voltage protection, and permit cooling operation down to 0'F. a. Evaporator coils shall have aluminum plate fins j. Control board shall monitor each refrigerant safety mechanically bonded to seamless internally switch independently. enhanced copper tubes with all joints brazed. Special k. Control board shall retain last 5 fault codes in non Phenolic coating shall be available as a factory volatile memory which will not be lost in the event of a option. power loss. b. Evaporator coils shall be of the direct expansion, draw-thru design. GAS HEATING SECTION c. Condenser coils shall have aluminum plate fins Shall be designed with induced draft combustion with mechanically bonded to seamless internally enhanced copper tubes with all joints brazed or post purge logic, energy saving direct spark ignition, and Micro-Channel aluminum tube, aluminum fins. redundant main gas valve. Venter wheel shall be constructed of stainless steel for corrosion resistance. d. Condenser coils shall be of the direct expansion, The heat exchanger shall be of the tubular type, draw-thru design. constructed of T1-40 aluminized steel for corrosion resistance and allowing minimum mixed air entering Refrigerant Circuit and Refrigerant Safety Components temperature of 25°F. Burners shall be of the inshot type, shall include: constructed of aluminum coated steel and contain air mixture adjustments. All gas piping shall enter the unit a. Independent fixed-orifice or thermally operated cabinet at a single location through either the side or expansion devices. curb without any field modifications. Integrated control b. Filter drier/strainer to eliminate any moisture or boards shall provide timed control of evaporator fan foreign matter. functioning and burner ignition. Heating section shall be c. Accessible service gage connections on both suction provided with the following minimum protection. and liquid lines to charge, evacuate, and measure a, Primary and auxiliary high-temperature limit switches. refrigerant pressure during any necessary servicing or troubleshooting, without losing charge. b. Induced draft motor speed sensor. d. The refrigeration system shall provide at least 1 YF of c. Flame roll out switch. sub-cooling at design conditions. d. Flame proving controls. Unit Controls: e. If any of the above safety devices trip, a LED (light- emitting diode) indicator shall flash a diagnostic code a. Unit shall be complete with self-contained low-voltage that indicates which safety switch has tripped. control circuit protected by a resettable circuit breaker on the 24-volt transformer side. NOTE: All 2 Stage Gas Heat, 60% Capacity 1st Stage, b. Unit shall incorporate a lockout circuit which provides 40% Capacity 2nd Stage. reset capability at the space thermostat or base unit, UNIT OPERATING CHARACTERISTICS should any of the following standard safety devices trip and shut off compressor. Unit shall be capable of starting and running at 125°F c. Loss-of-charge/Low-pressure switch. outdoor temperature, exceeding maximum load criteria of AHRI Standard 210/240. The compressor, with d. High-pressure switch. standard controls, shall be capable of operation down to e. Freeze-protection thermostat, evaporator coil. 0°F outdoor temperature. Unit shall be provided with fan time delay to prevent cold air delivery before heat exchanger warms up (Gas heat only). Unitary Sales Tool v1..5.9.0 Information is subject to change wlthoul notice. Check local codes Printed 10/28/2016 - MYORK Guia ELECTRICAL REQUIREMENTS All unit power wiring shall enter unit cabinet at a si factory provided location and be capable of side o bottom entry, to minimize roof penetrations and av unit field modifications. Separate side and bottom openings shall be provided for the control wiring. STANDARD LIMITED WARRANTIES • Compressor 5 Years • Heat Exchanger 10 Years • Electric Heat Element 5 Years • Other Parts 1 Year OPTIONAL OUTDOOR AIR Economizer — Outdoor and return air damper are interlocked and positioned by a fully-modl, spring return damper actuator. The maximum rate for the outdoor air intake dampers shall n exceed 2% when dampers are fully closed an operating against a pressure differential of 0.1 A unit -mounted potentiometer shall be provid( adjust the outdoor and return air damper asse take in CFM of outdoor air to meet the miniml, ventilation requirement of the conditioned spa during normal operation. During economizer operation, a mixed -air temperature control shi modulate the outdoor and return air damper assembly to prevent the supply air temperatui dropping below 55°F. The outdoor intake opei shall be covered with a rain hood that matche exterior of the unit. Water eliminator/filters shz provided. Simultaneous economizer/compres operation is also possible. Dampers shall fully on power loss. ADDITIONAL FACTORY INSTALLED OPTIONS • BAS Controls FIELD INSTALLED OPTIONS Roof Curb — 14" high, full perimeter curb witl- nailer (shipped knocked -down). Barometric Relief Damper — This damper at: can be used to relieve internal building air pre on units with an economizer without power e� This accessory includes a rain hood, a bird sc and a fully assembled damper. With bottom d connections, the damper should be mounted opening in the return air panel. With horizont� ductwork, the accessory should be mounted c return air duct. Unitary Sales Tool 0.5.9.0 Information is subject to change without notice. Check local codes, Printed 10/28/2016 2012 Washington State Energy Code Compliance Forms for Commercial, Group R1, and > 3 story R2 and R3 h`ll co-w-Ul Sz ULL 6 U zu1b PERMIT CENTER Mechanical Summary MECH-SUM 2012 Seattle Energy Code Compliance Forms for Commercial Buildiaas inch,din R2 li R3 over 3 stories and all R1 Revised Sept 2015 Project Info Project Address SOLA SALON STUDIOS Date 12/15/2016 351 STRANDER BLVD For Building Dept. Use TUKWILA, WA 98188 Applicant Name PRECISE HEATING AND COOLING Applicant Address P.0, BOX 1455, MONROE, WA, 98272 Applicant Phone 206-510-4250 New Building L i Building Addition Fenant Improvement system Retrofit No System Changes Project Description Briefly describe mechanical systems in 4 SUPPLY AND DUCT SYSTEMS FOR EACH OF 4 ROOF -FOP AHUS 2 EXHAUST SYSTEMS TO SERVE 2 the text box provided NEW ROOFTOP FANS. -] Total Bldg Performance notal Bldg Performance compliance Includes all mandatory provisions per C401 2 Option 2 ME Cl I -SUM, MECH-CIIK, and 0407 Energy Analysis Summary forms required Mechanical Systems Summary Air Compliance Heating Fan Flow Economizer Ventilation Equip ID Type of System (Note 1) Sl Served Path and Cooling Controls (Note 2) (Note 3) Energy Recovery AHI -11 UNITARY ROOFTOP AHU WEST SIDE STUDIOS Complex multi zone system Heating and cooling Constant volume (CV) Yes Not Applicable Not Required AHU-2 UNITARY ROOFTOP AHU MIDDLE WEST STUDIOS Complex multi zone system Heating and cooling Constant volume (CV) Yes Not Applicable Not Required AHU-3 UNITARY ROOFTOP AHIJ MIDDLE EAST STUDIOS Complex multi zone system Heating and cooling g Constant volume (CV) Yes Not Applicable Not Required AHU-4 UNITARY ROOFTOP AHU EAST SIDE STUDIOS Complex multi zone system Heating and cooling Constant volume (CV) Yes Not Applicable Not Required EAST SIDE/CENTRAL Simple single No heating or Constant No cooling, Minimum per Not Required EF -1 ROOFTOP EXHAUST FAN STUDIOS zone system cooling volume (CV) NA IMC Simple single No heating or Constant No cooling, Minimum per Not Required EF -1 ROOFTOP EXHAUST FAN WEST SIDE STUDIOS zone system cooling volume (CV) NA IMC 1 r-1 A MF -M P- -61 WNW V L_ A. - Note Provide basic description of system type for example unitary rooftop air handier built-up central air handler sing) packaged, split system or packaged -air furnace electric resistance heater, 4 -pipe fan coil. VRF ystem, energy recovery air handier. terminal air conditioner or heat pump, unit heater. warm of TL -scarce heat pump, etc. qity *%-"IR exception make-up air system ground or water e.otton taken from drop down menu and complete MLCH- F CON um arycfefinitionsofeai;h,, to select Note 2 - if taking an exception air economizer, exception are listed in MLCH-ECONO Note 3 If ventilation "Not applicable" is selected provide explanation in Project Oescoption box above [--- Ilydronic chilled water Water loop heat pump ] No hydropic systems IIVAC Hydronic Systems I CORRECTION I I Hyaronic heating Geothermal CORR_ F quipmentType (s) No service water systems Hot water heating tank($) Instantaneous Heat exchangE� from space heat boiler or Service Water Heating Dedicated boiler central hot waterlstLani Systems RECEIVED Distribution Type (s) Circulation System J On -demand CITY OF TUKWILA h`ll co-w-Ul Sz ULL 6 U zu1b PERMIT CENTER 7()97 lA/nchinntnn Ctntp f-nernv Cone (­.mmr)lianre Forms for Commercial. Group R1, and > 3 story R2 and R3 L 1 Mechanical Plans ] MPCIi CiQ Dorm Mechanical Schedules Indicate location of equipment compliance information If provided on plans then MF_CH-EQ forms are not required, however. include on plans all applicable compliance information listed in MF_CH-EQ tables. n Load calculation summary ❑ MECH-LOAD-CALC Form Provide design load calculations for all mechanical systems and equipment serving the building heating, cooling or ventilating needs. If a load calculation summary is provided with the permit documents that includes all applicable Design Load Calculations compliance information then the Ml -"C[ I -LOAD -CAI C form is not required. Equipment retrofit and repair projects where design loads in space(s) served have not changed from original design conditions are not required to perform load calculations nn,� nl...ka +..n Q++o Gnn—, rnrip r,�n,nlianre Fnrms for Commercial, Group R1, and > 3 story R2 and R3 2012 Seattle Energy Code Compliance Forms for Commercial Buildings including R2 & R3 over 3 stories and all R1 Revised Sept 2015 �] Protect includes HVAC air distribution systems that provide heating and/or cooling If yes, provide a MECH-FANSYS -SUM form I'an Power ❑ For one or more systems, the total fan motor nameplate hp of all fans in HVAC system exceeds Shp. If yes. provide a seperate MECH-FANSYS form for each HVAC system exceeding the 5 horsepower threshold. Refer to Section C403.2 10 and ML=CH-FANSYS-DOC for requirements and exceptions. Commissioning Exception Commissioning will be provided for all applicable systems Summary Commissioning Exceptions' Describe means of eligibilty for commissioning exception (capacity, �_ Mechanical system(s) etc) for all systems noted as taking exception in Mechanical Systems Summary table. Refer to Section Service water heating C408.2 and C408.4 for exceptions. system(s) For systems requiring commissioning. Figure C408.1 2 1 Commissioning Compliance Checklist shall be submitted to the code official upon project completion. Low Energy and Semi-fleated Spaces (Note 6 and 7) Peak Space Heating Cooling Conditioning Space Type Area Served, Capacity, Btu/h Capacity, Btu/h Capacity, Compliance Location in Plan(s) Space(s) Served square feet (Note 4) (Note 5) Btu/h-sf Check Notes Note 4 - Provide total installed heating output capacity of systems serving Low Energy or Sena -I feated space(s) in btuh Note 5 - Provide total installed cooling capacity of system serving Low Energy space(s) in Btu/h Not allowed for semi -heated spaces. Enter 0 if oo cooling. Note 6 - Refer to Section C101.5.2 Low E=nergy Building. Intalled peak space conditioning capacity. heating or cooling, may not exceed 3 4 Btu/h-sf Note 7 - Refer to Section C402 1.4 and Semi -Ideated Space definition in Chapter 2 1 otal heating output capacity may not exceed 8 btuh/sf. Only systems without electric resistance heating and no cooling are eligible for the wall insulation exception under semi. heated City of Tukwila Allan Ekberg, Mayor Department of Community Development Jack Pace, Director December 12, 2016 LAMAR MOORE PO BOX 1455 MONROE, WA 98272 RE: Correction Letter # 1 MECHANICAL Permit Application Number M16-0182 SOLA SALON STUDIOS - 351 STRANDER BLVD Dear LAMAR MOORE, This letter is to inform you of corrections that must be addressed before your development permit can be approved. All correction requests from each department must be addressed at the same time and reflected on your drawings. I have enclosed comments from the following departments: BUILDING - DEPARTMENT: KC ELLIS at 206-431-3677 if you have questions regarding these comments. • Provide: 1. structural support calculations for the rooftop units 2. complete and return the WSEC mechanical summary sheets. Please address the comments above in an itemized format with applicable revised plans, specifications, and/or other documentation. The City requires that two 2 sets of revised plan pages, specifications and/or other documentation be resubmitted with the appropriate revision block. In order to better expedite your resubmittal, a'Revision Submittal Sheet' must accompany every resubmittal. I have enclosed one for your convenience. Corrections/revisions must be made in person and will not be accepted through the mail or by a messenger service. If you have any questions, I can be reached at 206-433-7165. Sincerely, tey Permit Technician File No. M16-0182 6300 Southcenter Boulevard Suite #100 • Tukwila Washington 98188 • Phone 206-431-3670 • Fax 206-431-3665 PERMIT COORD COPY. PLAN REVIEW/ROUTING SLIP PERMIT NUMBER: M16-0182 DATE: 12/30/16 PROJECT NAME: SOLA SALON STUDIOS SITE ADDRESS: 351 STRANDER BLVD Original Plan Submittal Revision # before Permit Issued X Response to Correction Letter # 1 Revision # after Permit Issued DEPARTMENTS: kJ tM16 Tv Building Division Fire Prevention ❑ Planning Division ❑ Public Works ❑ Structural ❑ Permit Coordinator PRELIMINARY REVIEW: DATE: 01/03/17 Not Applicable ❑ Structural Review Required ❑ (no approval/review required) REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: DUE DATE: Approved ❑ Approved with Conditions ❑ Corrections Required ❑ Denied ❑ (corrections entered in Reviews) (ie: Zoning Issues) Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: 01/31/17 ]2/18/2013 PERMIT COORD COPY PLAN REVIEW/ROUTING SLIP PERMIT NUMBER: M16-0182 DATE: 12/05/16 PROJECT NAME: SOLA SALON STUDIOS SITE ADDRESS: ' 351 STRANDER BLVD X Original Plan Submittal Revision # before Permit Issued Response to Correction Letter # Revision # after Permit Issued DEPARTMENTS: wl� W KWU Building Division Fire Prevention Planning Division ❑ Public Works ❑ Structural ❑ Permit Coordinator PRELIMINARY REVIEW: DATE: 12/06/16 Not Applicable ❑ Structural Review Required ❑ (no approval/review required) REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: Approved ❑ Corrections Required ❑ (corrections entered in Reviews) Notation: REVIEWER'S INITIALS: DUE DATE: 01/03/17 Approved with Conditions ❑ Denied ❑ (ie: Zoning Issues) DATE: Permit Center Use Only CORRECTION LETTER MAILED: owh Departments issued corrections: Bldg Fire ❑ Ping ❑ PW ❑ Staff Initials: 12/18/2013 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Web site: http://www.Tukwi]aWA.gov REVISION SUBMITTAL Revision submittals must be submitted in person at the Permit Center. Revisions will not be accepted through the mail, fax, etc. Date: 1ZI Plan Check/Permit Number: M16-0.182 ❑ Response to Incomplete Letter # ®, Response to Correction Letter # 1 ❑ Revision # after Permit is Issued ❑ Revision requested by a City Building Inspector or Plans Examiner ❑ Deferred Submittal # Project Name: SOLA SALON STUDIOS Project Address: 351 STRANDER Contact Person: 1.(n-tY a r- M 0-0 re Summary of Revision: L v �-L'u b F'i) K 1E c4-" U- kL fu Sheet Number(s): "Cloud" or highlight all areas of revision Received at the City of Tukwila Permit Cei Phone Number: IZo 6 J n 6– l 2-5-o Steu-( ru ( k4L, IN—Entered in TRAKiT on W:\Permit Cemer\Applications-Handouts\Templaies\Porms\Word DocumentARevision Submittal Porm.doc Revised: August 2015 PRECISE HEATING & COOLING LLC Home Espafiol Contact Safety & Health Claims & Insurance OnWashington State Department of Labor & Industries PRECISE HEATING & COOLING LLC Owner or tradesperson PO BOX 1455 Wesco Insurance Co MONROE, WA 98272 Principals 206-861-2525 MOORE, LAMAR RALPH, PARTNER/MEMBER SNOHOMISH County STRINGER, MICHAEL Effective date LEE, PARTNER/MEMBER 04/20/2014 (End: 04/24/2015) Expiration date Doing business as PRECISE HEATING & COOLING LLC WA UBI No. Business type 603 122 887 Limited Liability Company Governing persons LAMAR MOORE MICHAEL L STRINGER; License Page 1 of 2 Search L&I �— — A-'LIndex Help MyL&I Workplace Rights Trades & Licensing Verify the contractor's active registration / license / certification (depending on trade) and any past violations. Construction Contractor Active. .......................................................... Meets current requirements. License specialties Heating/Vent/Air-Conditioning and Refrig (HVAC/R) License no. PRECIHC891 L9 Effective — expiration 0612912011— 06/29/2017 Bond Wesco Insurance Co $6,000.00 Bond account no. 46W BO43501 Received by L&I Effective date 04/07/2014 04/20/2014 Expiration date Until Canceled Bond history Insurance ....................... Ohio Security Ins Co $1,000,000.00 Policy no. BKS55371340 Received by L&I Effective date 12/02/2016 11/29/2016 Expiration date 1 112 912 01 7 Help us improve https:Hsecure.Ini.wa.gov/verify/Detail.aspx?UBI=603122887&LIC=PRECIHC891L9&SAW= 1/9/2017 PRECISE HEATING & COOLING LLC Insurance history Savings ................... No savings accounts during the previous 6 year period. Lawsuits against the bond or savings No lawsuits against the bond or savings accounts during the previous 6 year period. L&I Tax debts ............................... No L&I tax debts are recorded for this contractor license during the previous 6 year period, but some debts may be recorded by other agencies. License Violations ........................................... Infraction no. .................... EJACH00852Satisfied .................... Issue date RCW/WAC 08/06/2015 19.28.041 RCW Violation city Violation amount MONROE $500.00 Type of violation ELECTRICAL CITATION Description Offering, bidding, advertising, or performing electrical installations, alterations or maintenance outside the scope of the firm's specialty electrical contractors license. (Installing low voltage conductors at a commercial site) Infraction no. ECHAE00750Satisfied .................... Issue date RCWiWAC 02/01/2012 19.28.041 RCW Violation city Violation amount MONROE $500.00 Type of violation ELECTRICAL CITATION Description Offering to perform, submitting a bid for, advertising, installing or maintaining cables, conductors or equipment that convey or utilize electrical current without having a valid electrical contractor license. Workers' comp Do you know if the business has employees? If so, verify the business is up-to-date on workers' comp premiums. L&I Account ID 217,035-00 ......................... Account is current. Doing business as PRECISE HEATING & COOLING LLC Estimated workers reported Quarter 3 of Year 2016 "4 to 6 Workers" L&I account representative T4 I MELVINA RAMSDELL (360)902-4814 - Email: RAMM235@lni.wa.gov Workplace safety and health Check for any past safety and health violations found on jobsites this business was responsible for. 0 Washington State Dept. of Labor & Industries. Use of this site is subject to the laws of the state of Washington. Page 2 of 2 Help us improve https:Hsecure.Ini.wa.gov/verify/Detail.aspx?UBI=603122887&LIC=PRECIHC891L9&SAW= 1/9/2017 AIR HANDLER SCHEDULE TAG MAKE MODEL WEIGHT ESP CFM OSA ELECTRICAL EER ECONO VOLTS PHASE M.C.A. AHU-1 YORK ZE060H 12B4C1 EAA1 Al 632 0.60 2000 ATTACH TO GRID 460 3 2000 11.80 YES AHU-2 YORK ZXG08D4B3AA2B111A2 791 0.60 3000 SHEETROCK 460 3 20.4 11.00 YES AHU-3 YORK ZXG08D4B3AA2B111 A2 791 0.60 3000 El 460 3 20.4 11.00 YES AHU-4 YORK ZXG08D4B3AA2B111 A2 791 0.60 3000 ROUND DUCT UP 460 3 20.4 11.00 YES FAN SCHEDULE TAG MAKE AND MODEL CFM ESP SONES VOLTAGE TYPE WEIGHT BDD NOTES EF -1 GREENHECK GB -141-7 1200 .81 13 460 ROOFTOP 72 LBS YES ATTACH TO GRID EF -2 PRICE 80 2000 ATTACH TO GRID EG -2 460 ROOFTOP SHEETROCK YES PRICE SMCD ZONE DAMPER SCHEDULE TAG MAKE AND MODEL VOLTAGE NOTES ZD WATTMASTER AZ2-200-ZV1 120 PROVIDE 120V FOR CONTROL POWER BYPASS DAMPER SCHEDULE TAG MAKE AND MODEL VOLTAGE NOTES ZD WATTMASTER AZ2-301-RB-16 120 PROVIDE 120V FOR CONTROL POWER VICINITY MAP PARCEL NUMBER: PERMIT NUMBER: 'di �;'s�ir^= iIJju�'t to err^�rS c'',Etd CJI is i Approval of ccr►5 '70i; d CLItan's Lois mot au ho ; o the violation or inv adopted code or ordinance. Fuc;::pi of approved Fiaid Cop and conditions is acno°�;ic�'jr�d: Ey. L Data: 1_l AOI -,vii BUILDING DIVISION GRILL REGISTER AND DIFFUSER SCHEDULE 17'. ! trC? TAG REVISIONS No charges NOTES shall b -i made to the scope PRICE SPD f w rk without prior approval of SD -2 Tukwila Building Division. NOTE: l ie I ions w*;Il rcquire a new plan submittal and ma include additional plan review fees. I PARCEL NUMBER: PERMIT NUMBER: 'di �;'s�ir^= iIJju�'t to err^�rS c'',Etd CJI is i Approval of ccr►5 '70i; d CLItan's Lois mot au ho ; o the violation or inv adopted code or ordinance. Fuc;::pi of approved Fiaid Cop and conditions is acno°�;ic�'jr�d: Ey. L Data: 1_l AOI -,vii BUILDING DIVISION GRILL REGISTER AND DIFFUSER SCHEDULE 17'. ! trC? TAG MAKE AND MODEL SIZE NOTES SD -1 PRICE SPD 24" X 2411 ATTACH TO GRID_ SD -2 PRICE SMCD 0r' X 1011 10 11 0" SHEETROCK RG -1 PRICE 80 12" X 24" ATTACH TO GRID RG -2 PRICE 80 24" X 24" ATTACH TO GRID EG -1 PRICE 80 12" X 24" ATTACH TO GRID EG -2 PRICE SMCD 6" X 6" SHEETROCK EG -2 PRICE SMCD 10" X 1011 0" SHEETROCK HVAC ABBREVIATIONS AFF ABOVE FINISHED FLOOR AHU AIR HANDLING UNIT BDD BACKDRAFT DAMPER BPD BY-PASS DAMPER BTUH BRITISH THERMAL UNIT PER HOUR CD CEILING DIFFUSER CFM CUBIC FEET PER MINUTE DB DECIBAL DH DUCT HEATER EA EXHAUST AIR EER ENERGY EFFICIENCY RATIO EG EXHAUST GRILLE ESP EXTERNAL STATIC PRESSURE EXH EXHAUST FCU FAN COIL UNIT FD FIRE DAMPER, FLOOR DRAIN FPM FEET PER MINUTE FSD FIRE AND SMOKE DAMPER GF GAS FURNACE GRD GRILLE, REGISTER, DIFFUSER OR: 0- tat e Electrical Ff.Plumbing (Gas Piping City of Tukwila ILDING Dlyl 1 HVAC ABBREVIATIONS HP HORSEPOWER, HEAT PUMP HVAC HEATING, VENTILATING, AND AIR CONDITIONING NTS NOT TO SCALE OBD OPPOSED BLADE DAMPER OD OUTSIDE DIMENSION OR DIAMETER OSA OUTSIDE AIR OU OUTDOOR UNIT RG RETURN GRILLE RPM REVOLUTIONS PER MINUTE RA RETURN AIR SA SUPPLY AIR SG SUPPLY GRILLE SP STATIC PRESSURE TG TRANSFER GRILLE VAV VARIABLE AIR VOLUME VFD VARIABLE FREQUENCY DRIVE VTR VENT TO ROOF VVT VARIABLE VOLUME AND TEMPERATURE ZD ZONE DAMPER HVAC LEGEND SYMBOL DESCRIPTION H SUPPLY DIFFUSER F- RETURN GRILLE + DAMPER O THERMOSTAT O SENSOR p(1) EXHAUST FAN Z EXHAUST GRILLE CONDENSING UNIT 0 INLINE EXHAUST FAN ROOFTOP EXHAUST FAN _j SIDEWALL EXHAUST FAN ® SUPPLY GRILLE < VAV FAN BOX CEILING EXHAUST FAN ® GAS METER [� WT DAMPER FM T -BAR SUPPLY DIFFUSER E] T -BAR RETURN GRILLE f 1ff��Il CEILING RADIATION DAMPER ABOVE DIFFUSER El CEILING RADIATION DAMPER ABOVE GRILLE FDO FIRE DAMPER FSDIo FIRE SMOKE DAMPER Os SMOKE DETECTOR FLEXIBLE DUCT SARA ROUND DUCT UP ROUND DUCT DOWN RTu ROOFTOP UNIT EF -1 EXHAUST FAN SF -1 SUPPLY FAN UH -1 UNIT HEATER TRH -1 INFRARED HEATER HP -1 HEAT PUMP AC -1 AIR CONDITIONING UNIT AHU-1 AIR HANDLING UNIT HVAC NOTES 1. DUCT CONSTRUCTION, SEALING, AND INSULATION TO MEET REQUIREMENTS OF SECTION C403.2.9 OF THE 2015 WSEC. ALL DUCTWORK SHOWN IS LOW PRESSURE UNLESS INDICATED OTHERWISE. 2. SMOKE DETECTOR(S) INSTALLED IN MAIN RETURN AS PER SECTION 606 OF THE 2015 IMC. HVAC SMOKE DUCT DETECTORS SHALL SHUT DOWN POWER TO THE UNIT UPON ACTIVATION AND, A "SUPERVISOR " ZONE SHALL BE INITIATED AT THE FIRE ALARM PANEL UPON SMOKE DUCT DETECTOR ACTIVATION. IMC SECTION, 606.2.1 3. EQUIPMENT INSTALLATION INSTRUCTIONS TO BE ON SITE FOR INSPECTIONS. 4. ALL HVAC EQUIPMENT TO BE LABELED TO THE SPACE SERVED. 5. DUCTS TO BE SUPPORTED AT EACH DIRECTION CHANGE - VERTICAL AT 12'-0" MAX., HORIZONTAL AT 10'-0" MAX. WITH STRAP, OR 8'-0" MAX FROM TRAPEZE SUPPORT. 6. SYSTEM CONTROLS TO MEET 2015 WSEC SECTIONS 403.2.4.2/3 7. THE HVAC INSTALLATION SHALL BE COMPLETE WHEN ALL SECTIONS OF 408 WSEC HAVE BEEN SATISFIED. THIS SHALL INCLUDE AS -BUILT DRAWINGS, SUBMITTALS, O&M MANUALS SYSTEM BALANCE REPORT, AND COMMISSIONING REPORT. 8. ALL ECONOMIZERS PROVIDED SHALL MEET 2015 WSEC SECTIONS C403.2.4.7, C403.3 9. ALL SUPPLY GRILLES TO HAVE VOLUME DAMPERS FOR BALANCING OF SYSTEM UPON COMPLETION 10. ALL PIPING TO BE INSULATED ACCORDING TO 2015 IEC C402.10 11. FRESH AIR INTAKE AND RELIEF/EXHAUST, WILL BE EQUIPPED WITH LOW LEAK, CLASS 1A MOTORIZED DAMPERS THAT AUTOMATICALLY CLOSE DURING UNOCCUPIED HOURS TO COMPLY WITH 2015 SEC SECTION C402.4.5.2 xka. 3j iiS 2 P.O. BOX 1 455 ONROE, WA 98272 206.510.4250 C) 00 H > F- m z Z p(1) o 0 Q�� < �- _j Y < T- J M0 � M APPROVAL STAMP DRAWL BY: KIRK OFFERDAHL DRAWN FOR: PRECISE HEATING & COOLING DATE STARTED: 8/5/2016 DATE PLOTTED: 12/5/2016 SCALE: REVISIONS: / / I DEC 0 . 201 1 DESCRIr11 t. lEVVED FOR COVIfPM COMPLIANCE APPROVED JAN 06 2017 P2 - SHEET -,I BUIL1 ING DIVISION OF M5 HVAC NOTES O MANUAL BALANCING DAMPERS TO BE INSTALLED ON ALL SUPPLY DIFFU O BYPASS DAMPER (BD -1) TO BE SIZED TO BYPASS DUCTWORK HVAC - UPlp=2-`,LY AND RETURN SYSTEMS SCALE: 1/411 = 11 APPROVAL STAMP DRAWN BY: KIRK OFFERDAHL DRAViN FOR: PRECISE HEATING & COOLING DATE STARTED: 11/17/2016 DATE PLOTTED: 12/5/2016 SCALE: 1/4 to = 1' REVISIONS: NOW klr zl?• APPROVED w. RECEIVED CITY OF TUKWILA OF DEC 05 2016 M5 PERMIT CENTER HVAC NOTES O BALANCING DAMPERS TO BE INSTALLED ON ALL EXHAUST GRILLES Q INSTALL BALANCING DAMPERS IN DUCT DIRECTLY ABOVE AND DIFFUSER 0001111 <Ali A �r. 1455 s� �� ��r� �� MSN ROE, WA Q, 98272 2 206.510.4250 O — 2 2 XX O. 0 . T T 0 0 - ,y C O.: rf, c 2 0-1 4 � S i TQ T <. o:_ o.-. o: 0r co a ° ° 0 0 9c ry m 0 0- LLQ v) Co C) 00 O � �.. . : 000 T: 0 �0 � =baa j 1. w o 5� 0110 0 a— .� y C co 01 w�w'� f iia � „ - 11,11 -o:� T T C� L glmmm0 o I I o 0 _ = at �� CO 0 MK—u 0APPROVAL STAMP 9c 'uff �x {0� 4 1�� �� O .� /� 74, 7t— IF, 0 � �a 0 0 — 0 0 o 0 ° 0 0 DRAWN BY: T c O �� 1, KIRK OFFERDAHL T T �T DRAWN FOR: PRECISE HEATING & COOLING C DATE STARTED: : A 11/17/2016 0 0 0 0 0:: o_ o 0_1 o o: o _ o, o: o:; 0 0, DATE SLOTTED: 12/5/2016 c T SCALE: T nT T T ..,., 1 4 1 °101 =- REVISIONS: 0 ° 0 Q 0 O 5132 S . �o _ r O;_ O.� DES cR • a INK D FOR w PRO RE— L WORAPPROVEDr � INCE 3: to Ing womilgilm JAN 0 6 2017 a SHEET: i 0 u i a H v Au" Rmm%CP®EX"oF1'AUzr3T SYSI'EM BUIL IN VISION 4 IT RECEIVED 1 SCALE: 1/4" = 1' CITY OF TUKWILA DECU 0 5 2016 OF PERMIT CENTER M 5 I� � IMC 2015 MINIMUM VENTILATION REQUIREMENTS ROOM TYPE lAREAlQTY OCC. LOAD # PEOPLE OSA/PERSON OSA SUPPLY RETURN EXHAUST BREAK ROOM 210 1 25 PER 1000 SF 6 20 118 250 - 250 MENS 52 1 - - - - - - 70 WOMENS 220 1 - - - - 250 - 210 CORRIDOR 1650 1 0.06 CFM/SF - - 99 400 300 - ENTRY 60 1 0.06 CFM/SF - - 4 200 - - SMALL STUDIO 110 28 25 PER 1000 SF 3 20 69 200 200 70 MEDIUM STUDIO 150 6 25 PER 1000 SF 4 20 93 250 250 100 LARGE STUDIO 210 4 25 PER 1000 SF 5 20 130 330 330 140 JANITORS CLOSET 10 1 1 1 - - - I - I - I - 1 100 ZONE DAMPER SCHEDULE SYMBOL SIZE MODEL COMMENTS ZD 1-1 8" AZ 2 -300 -RI -XX PROVIDE CONTROL POWER ZD 1-2 8" AZ 2 -300 -RI -XX PROVIDE CONTROL POWER ZD 1-3 8" AZ 2 -300 -RI -XX PROVIDE CONTROL POWER ZD 1-4 10" AZ 2 -300 -RI -XX PROVIDE CONTROL POWER ZD 1-5 8" AZ 2 -300 -RI -XX PROVIDE CONTROL POWER BD 1 14" AZ 2 -300 -RI -XX PROVIDE CONTROL POWER ZD 2-1 8" AZ 2 -300 -RI -XX PROVIDE CONTROL POWER ZD 2-2 8" AZ 2 -300 -RI -XX PROVIDE CONTROL POWER ZD 2-3 8" AZ 2 -300 -RI -XX PROVIDE CONTROL POWER ZD 2-4 8" AZ 2 -300 -RI -XX PROVIDE CONTROL POWER ZD 2-5 10" AZ 2 -300 -RI -XX PROVIDE CONTROL POWER ZD 2-6 10" AZ 2 -300 -RI -XX PROVIDE CONTROL POWER ZD 2-7 8" AZ 2 -300 -RI -XX PROVIDE CONTROL POWER ZD 2-8 8" AZ 2 -300 -RI -XX PROVIDE CONTROL POWER ZD 2-9 8" AZ 2 -300 -RI -XX PROVIDE CONTROL POWER ZD 2-10 8" AZ 2 -300 -RI -XX PROVIDE CONTROL POWER ZD 2-11 10" AZ 2 -300 -RI -XX PROVIDE CONTROL POWER ZD 2-12 10" AZ 2 -300 -RI -XX PROVIDE CONTROL POWER BD 2 16" AZ 2 -300 -RI -XX PROVIDE CONTROL POWER ZD 3-1 8" AZ 2 -300 -RI -XX PROVIDE CONTROL POWER ZD 3-2 8" AZ 2 -300 -RI -XX PROVIDE CONTROL POWER ZD 3-3 8" AZ 2 -300 -RI -XX PROVIDE CONTROL POWER ZD 3-4 10" AZ 2 -300 -RI -XX PROVIDE CONTROL POWER ZD 3-5 10" AZ 2 -300 -RI -XX PROVIDE CONTROL POWER ZD 3-6 10" AZ 2 -300 -RI -XX PROVIDE CONTROL POWER ZD 3-7 8" AZ 2 -300 -RI -XX PROVIDE CONTROL POWER ZD 3-8 8" AZ 2 -300 -RI -XX PROVIDE CONTROL POWER ZD 3-9 8" AZ 2 -300 -RI -XX PROVIDE CONTROL POWER ZD 3-10 10" AZ 2 -300 -RI -XX PROVIDE CONTROL POWER BD 3 16" AZ 2 -300 -RI -XX PROVIDE CONTROL POWER ZD 4-1 8" AZ 2 -300 -RI -XX PROVIDE CONTROL POWER ZD 4-2 8" AZ 2 -300 -RI -XX PROVIDE CONTROL POWER ZD 4-3 10" AZ 2 -300 -RI -XX PROVIDE CONTROL POWER ZD 4-4 8" AZ 2 -300 -RI -XX PROVIDE CONTROL POWER ZD 4-5 8" AZ 2 -300 -RI -XX PROVIDE CONTROL POWER ZD 4-6 8" AZ 2 -300 -RI -XX PROVIDE CONTROL POWER ZD 4-7 8" AZ 2 -300 -RI -XX PROVIDE CONTROL POWER ZD 4-8 8" AZ 2 -300 -RI -XX PROVIDE CONTROL POWER ZD 4-9 8" AZ 2 -300 -RI -XX PROVIDE CONTROL POWER ZD 4-10 8" AZ 2 -300 -RI -XX PROVIDE CONTROL POWER ZD 4-11 10" AZ 2 -300 -RI -XX PROVIDE CONTROL POWER ZD 4-12 10" AZ 2 -300 -RI -XX PROVIDE CONTROL POWER ZD 4-13 8" AZ 2 -300 -RI -XX PROVIDE CONTROL POWER BD 4 16" AZ 2 -300 -RI -XX PROVIDE CONTROL POWER AIR HANDLER SCHEDULE TAG MAKE MODEL WEIGHT ESP CFM OSA ELECTRICAL EER ECONO VOLTS PHASE M.C.A. AHU-1 YORK ZE060H 12B4C1 EAA1 Al 632 0.60 2000 ATTACH TO GRID 460 3 2000 11.80 YES AHU-2 YORK ZXG08D4B3AA2B111A2 791 0.60 3000 SHEETROCK 460 3 20.4 11.00 YES AHU-3 YORK ZXG08D4B3AA2B111 A2 791 0.60 3000 El 460 3 20.4 11.00 YES AHU-4 YORK ZXG08D4B3AA2B111 A2 791 0.60 3000 ROUND DUCT UP 460 3 20.4 11.00 YES FAN SCHEDULE TAG MAKE AND MODEL CFM ESP SONES VOLTAGE TYPE WEIGHT BDD NOTES EF -1 GREENHECK GB -141-7 1200 .81 13 460 ROOFTOP 72 LBS YES ATTACH TO GRID EF -2 PRICE 80 2000 ATTACH TO GRID EG -2 460 ROOFTOP SHEETROCK YES PRICE SMCD ZONE DAMPER SCHEDULE TAG MAKE AND MODEL VOLTAGE NOTES ZD WATTMASTER AZ2-200-ZV1 120 PROVIDE 120V FOR CONTROL POWER BYPASS DAMPER SCHEDULE TAG MAKE AND MODEL VOLTAGE NOTES ZD WATTMASTER AZ2-301-RB-16 120 PROVIDE 120V FOR CONTROL POWER VICINITY MAP PARCEL NUMBER: PERMIT NUMBER: 'di �;'s�ir^= iIJju�'t to err^�rS c'',Etd CJI is i Approval of ccr►5 '70i; d CLItan's Lois mot au ho ; o the violation or inv adopted code or ordinance. Fuc;::pi of approved Fiaid Cop and conditions is acno°�;ic�'jr�d: Ey. L Data: 1_l AOI -,vii BUILDING DIVISION GRILL REGISTER AND DIFFUSER SCHEDULE 17'. ! trC? TAG REVISIONS No charges NOTES shall b -i made to the scope PRICE SPD f w rk without prior approval of SD -2 Tukwila Building Division. NOTE: l ie I ions w*;Il rcquire a new plan submittal and ma include additional plan review fees. I PARCEL NUMBER: PERMIT NUMBER: 'di �;'s�ir^= iIJju�'t to err^�rS c'',Etd CJI is i Approval of ccr►5 '70i; d CLItan's Lois mot au ho ; o the violation or inv adopted code or ordinance. Fuc;::pi of approved Fiaid Cop and conditions is acno°�;ic�'jr�d: Ey. L Data: 1_l AOI -,vii BUILDING DIVISION GRILL REGISTER AND DIFFUSER SCHEDULE 17'. ! trC? TAG MAKE AND MODEL SIZE NOTES SD -1 PRICE SPD 24" X 2411 ATTACH TO GRID_ SD -2 PRICE SMCD 0r' X 1011 10 11 0" SHEETROCK RG -1 PRICE 80 12" X 24" ATTACH TO GRID RG -2 PRICE 80 24" X 24" ATTACH TO GRID EG -1 PRICE 80 12" X 24" ATTACH TO GRID EG -2 PRICE SMCD 6" X 6" SHEETROCK EG -2 PRICE SMCD 10" X 1011 0" SHEETROCK HVAC ABBREVIATIONS AFF ABOVE FINISHED FLOOR AHU AIR HANDLING UNIT BDD BACKDRAFT DAMPER BPD BY-PASS DAMPER BTUH BRITISH THERMAL UNIT PER HOUR CD CEILING DIFFUSER CFM CUBIC FEET PER MINUTE DB DECIBAL DH DUCT HEATER EA EXHAUST AIR EER ENERGY EFFICIENCY RATIO EG EXHAUST GRILLE ESP EXTERNAL STATIC PRESSURE EXH EXHAUST FCU FAN COIL UNIT FD FIRE DAMPER, FLOOR DRAIN FPM FEET PER MINUTE FSD FIRE AND SMOKE DAMPER GF GAS FURNACE GRD GRILLE, REGISTER, DIFFUSER OR: 0- tat e Electrical Ff.Plumbing (Gas Piping City of Tukwila ILDING Dlyl 1 HVAC ABBREVIATIONS HP HORSEPOWER, HEAT PUMP HVAC HEATING, VENTILATING, AND AIR CONDITIONING NTS NOT TO SCALE OBD OPPOSED BLADE DAMPER OD OUTSIDE DIMENSION OR DIAMETER OSA OUTSIDE AIR OU OUTDOOR UNIT RG RETURN GRILLE RPM REVOLUTIONS PER MINUTE RA RETURN AIR SA SUPPLY AIR SG SUPPLY GRILLE SP STATIC PRESSURE TG TRANSFER GRILLE VAV VARIABLE AIR VOLUME VFD VARIABLE FREQUENCY DRIVE VTR VENT TO ROOF VVT VARIABLE VOLUME AND TEMPERATURE ZD ZONE DAMPER HVAC LEGEND SYMBOL DESCRIPTION H SUPPLY DIFFUSER F- RETURN GRILLE + DAMPER O THERMOSTAT O SENSOR p(1) EXHAUST FAN Z EXHAUST GRILLE CONDENSING UNIT 0 INLINE EXHAUST FAN ROOFTOP EXHAUST FAN _j SIDEWALL EXHAUST FAN ® SUPPLY GRILLE < VAV FAN BOX CEILING EXHAUST FAN ® GAS METER [� WT DAMPER FM T -BAR SUPPLY DIFFUSER E] T -BAR RETURN GRILLE f 1ff��Il CEILING RADIATION DAMPER ABOVE DIFFUSER El CEILING RADIATION DAMPER ABOVE GRILLE FDO FIRE DAMPER FSDIo FIRE SMOKE DAMPER Os SMOKE DETECTOR FLEXIBLE DUCT SARA ROUND DUCT UP ROUND DUCT DOWN RTu ROOFTOP UNIT EF -1 EXHAUST FAN SF -1 SUPPLY FAN UH -1 UNIT HEATER TRH -1 INFRARED HEATER HP -1 HEAT PUMP AC -1 AIR CONDITIONING UNIT AHU-1 AIR HANDLING UNIT HVAC NOTES 1. DUCT CONSTRUCTION, SEALING, AND INSULATION TO MEET REQUIREMENTS OF SECTION C403.2.9 OF THE 2015 WSEC. ALL DUCTWORK SHOWN IS LOW PRESSURE UNLESS INDICATED OTHERWISE. 2. SMOKE DETECTOR(S) INSTALLED IN MAIN RETURN AS PER SECTION 606 OF THE 2015 IMC. HVAC SMOKE DUCT DETECTORS SHALL SHUT DOWN POWER TO THE UNIT UPON ACTIVATION AND, A "SUPERVISOR " ZONE SHALL BE INITIATED AT THE FIRE ALARM PANEL UPON SMOKE DUCT DETECTOR ACTIVATION. IMC SECTION, 606.2.1 3. EQUIPMENT INSTALLATION INSTRUCTIONS TO BE ON SITE FOR INSPECTIONS. 4. ALL HVAC EQUIPMENT TO BE LABELED TO THE SPACE SERVED. 5. DUCTS TO BE SUPPORTED AT EACH DIRECTION CHANGE - VERTICAL AT 12'-0" MAX., HORIZONTAL AT 10'-0" MAX. WITH STRAP, OR 8'-0" MAX FROM TRAPEZE SUPPORT. 6. SYSTEM CONTROLS TO MEET 2015 WSEC SECTIONS 403.2.4.2/3 7. THE HVAC INSTALLATION SHALL BE COMPLETE WHEN ALL SECTIONS OF 408 WSEC HAVE BEEN SATISFIED. THIS SHALL INCLUDE AS -BUILT DRAWINGS, SUBMITTALS, O&M MANUALS SYSTEM BALANCE REPORT, AND COMMISSIONING REPORT. 8. ALL ECONOMIZERS PROVIDED SHALL MEET 2015 WSEC SECTIONS C403.2.4.7, C403.3 9. ALL SUPPLY GRILLES TO HAVE VOLUME DAMPERS FOR BALANCING OF SYSTEM UPON COMPLETION 10. ALL PIPING TO BE INSULATED ACCORDING TO 2015 IEC C402.10 11. FRESH AIR INTAKE AND RELIEF/EXHAUST, WILL BE EQUIPPED WITH LOW LEAK, CLASS 1A MOTORIZED DAMPERS THAT AUTOMATICALLY CLOSE DURING UNOCCUPIED HOURS TO COMPLY WITH 2015 SEC SECTION C402.4.5.2 xka. 3j iiS 2 P.O. BOX 1 455 ONROE, WA 98272 206.510.4250 C) 00 H > F- m z Z p(1) o 0 Q�� < �- _j Y < T- J M0 � M APPROVAL STAMP DRAWL BY: KIRK OFFERDAHL DRAWN FOR: PRECISE HEATING & COOLING DATE STARTED: 8/5/2016 DATE PLOTTED: 12/5/2016 SCALE: REVISIONS: / / I DEC 0 . 201 1 DESCRIr11 t. lEVVED FOR COVIfPM COMPLIANCE APPROVED JAN 06 2017 P2 - SHEET -,I BUIL1 ING DIVISION OF M5 HVAC NOTES O MANUAL BALANCING DAMPERS TO BE INSTALLED ON ALL SUPPLY DIFFU O BYPASS DAMPER (BD -1) TO BE SIZED TO BYPASS DUCTWORK HVAC - UPlp=2-`,LY AND RETURN SYSTEMS SCALE: 1/411 = 11 APPROVAL STAMP DRAWN BY: KIRK OFFERDAHL DRAViN FOR: PRECISE HEATING & COOLING DATE STARTED: 11/17/2016 DATE PLOTTED: 12/5/2016 SCALE: 1/4 to = 1' REVISIONS: NOW klr zl?• APPROVED w. RECEIVED CITY OF TUKWILA OF DEC 05 2016 M5 PERMIT CENTER HVAC NOTES O BALANCING DAMPERS TO BE INSTALLED ON ALL EXHAUST GRILLES Q INSTALL BALANCING DAMPERS IN DUCT DIRECTLY ABOVE AND DIFFUSER 0001111 <Ali A �r. 1455 s� �� ��r� �� MSN ROE, WA Q, 98272 2 206.510.4250 O — 2 2 XX O. 0 . T T 0 0 - ,y C O.: rf, c 2 0-1 4 � S i TQ T <. o:_ o.-. o: 0r co a ° ° 0 0 9c ry m 0 0- LLQ v) Co C) 00 O � �.. . : 000 T: 0 �0 � =baa j 1. w o 5� 0110 0 a— .� y C co 01 w�w'� f iia � „ - 11,11 -o:� T T C� L glmmm0 o I I o 0 _ = at �� CO 0 MK—u 0APPROVAL STAMP 9c 'uff �x {0� 4 1�� �� O .� /� 74, 7t— IF, 0 � �a 0 0 — 0 0 o 0 ° 0 0 DRAWN BY: T c O �� 1, KIRK OFFERDAHL T T �T DRAWN FOR: PRECISE HEATING & COOLING C DATE STARTED: : A 11/17/2016 0 0 0 0 0:: o_ o 0_1 o o: o _ o, o: o:; 0 0, DATE SLOTTED: 12/5/2016 c T SCALE: T nT T T ..,., 1 4 1 °101 =- REVISIONS: 0 ° 0 Q 0 O 5132 S . �o _ r O;_ O.� DES cR • a INK D FOR w PRO RE— L WORAPPROVEDr � INCE 3: to Ing womilgilm JAN 0 6 2017 a SHEET: i 0 u i a H v Au" Rmm%CP®EX"oF1'AUzr3T SYSI'EM BUIL IN VISION 4 IT RECEIVED 1 SCALE: 1/4" = 1' CITY OF TUKWILA DECU 0 5 2016 OF PERMIT CENTER M 5 I� � IMC 2015 MINIMUM VENTILATION REQUIREMENTS ROOM TYPE lAREAlQTY OCC. LOAD # PEOPLE OSA/PERSON OSA SUPPLY RETURN EXHAUST BREAK ROOM 210 1 25 PER 1000 SF 6 20 118 250 - 250 MENS 52 1 - - - - - - 70 WOMENS 220 1 - - - - 250 - 210 CORRIDOR 1650 1 0.06 CFM/SF - - 99 400 300 - ENTRY 60 1 0.06 CFM/SF - - 4 200 - - SMALL STUDIO 110 28 25 PER 1000 SF 3 20 69 200 200 70 MEDIUM STUDIO 150 6 25 PER 1000 SF 4 20 93 250 250 100 LARGE STUDIO 210 4 25 PER 1000 SF 5 20 130 330 330 140 JANITORS CLOSET 10 1 1 1 - - - I - I - I - 1 100 ZONE DAMPER SCHEDULE SYMBOL SIZE MODEL COMMENTS ZD 1-1 8" AZ 2 -300 -RI -XX PROVIDE CONTROL POWER ZD 1-2 8" AZ 2 -300 -RI -XX PROVIDE CONTROL POWER ZD 1-3 8" AZ 2 -300 -RI -XX PROVIDE CONTROL POWER ZD 1-4 10" AZ 2 -300 -RI -XX PROVIDE CONTROL POWER ZD 1-5 8" AZ 2 -300 -RI -XX PROVIDE CONTROL POWER BD 1 14" AZ 2 -300 -RI -XX PROVIDE CONTROL POWER ZD 2-1 8" AZ 2 -300 -RI -XX PROVIDE CONTROL POWER ZD 2-2 8" AZ 2 -300 -RI -XX PROVIDE CONTROL POWER ZD 2-3 8" AZ 2 -300 -RI -XX PROVIDE CONTROL POWER ZD 2-4 8" AZ 2 -300 -RI -XX PROVIDE CONTROL POWER ZD 2-5 10" AZ 2 -300 -RI -XX PROVIDE CONTROL POWER ZD 2-6 10" AZ 2 -300 -RI -XX PROVIDE CONTROL POWER ZD 2-7 8" AZ 2 -300 -RI -XX PROVIDE CONTROL POWER ZD 2-8 8" AZ 2 -300 -RI -XX PROVIDE CONTROL POWER ZD 2-9 8" AZ 2 -300 -RI -XX PROVIDE CONTROL POWER ZD 2-10 8" AZ 2 -300 -RI -XX PROVIDE CONTROL POWER ZD 2-11 10" AZ 2 -300 -RI -XX PROVIDE CONTROL POWER ZD 2-12 10" AZ 2 -300 -RI -XX PROVIDE CONTROL POWER BD 2 16" AZ 2 -300 -RI -XX PROVIDE CONTROL POWER ZD 3-1 8" AZ 2 -300 -RI -XX PROVIDE CONTROL POWER ZD 3-2 8" AZ 2 -300 -RI -XX PROVIDE CONTROL POWER ZD 3-3 8" AZ 2 -300 -RI -XX PROVIDE CONTROL POWER ZD 3-4 10" AZ 2 -300 -RI -XX PROVIDE CONTROL POWER ZD 3-5 10" AZ 2 -300 -RI -XX PROVIDE CONTROL POWER ZD 3-6 10" AZ 2 -300 -RI -XX PROVIDE CONTROL POWER ZD 3-7 8" AZ 2 -300 -RI -XX PROVIDE CONTROL POWER ZD 3-8 8" AZ 2 -300 -RI -XX PROVIDE CONTROL POWER ZD 3-9 8" AZ 2 -300 -RI -XX PROVIDE CONTROL POWER ZD 3-10 10" AZ 2 -300 -RI -XX PROVIDE CONTROL POWER BD 3 16" AZ 2 -300 -RI -XX PROVIDE CONTROL POWER ZD 4-1 8" AZ 2 -300 -RI -XX PROVIDE CONTROL POWER ZD 4-2 8" AZ 2 -300 -RI -XX PROVIDE CONTROL POWER ZD 4-3 10" AZ 2 -300 -RI -XX PROVIDE CONTROL POWER ZD 4-4 8" AZ 2 -300 -RI -XX PROVIDE CONTROL POWER ZD 4-5 8" AZ 2 -300 -RI -XX PROVIDE CONTROL POWER ZD 4-6 8" AZ 2 -300 -RI -XX PROVIDE CONTROL POWER ZD 4-7 8" AZ 2 -300 -RI -XX PROVIDE CONTROL POWER ZD 4-8 8" AZ 2 -300 -RI -XX PROVIDE CONTROL POWER ZD 4-9 8" AZ 2 -300 -RI -XX PROVIDE CONTROL POWER ZD 4-10 8" AZ 2 -300 -RI -XX PROVIDE CONTROL POWER ZD 4-11 10" AZ 2 -300 -RI -XX PROVIDE CONTROL POWER ZD 4-12 10" AZ 2 -300 -RI -XX PROVIDE CONTROL POWER ZD 4-13 8" AZ 2 -300 -RI -XX PROVIDE CONTROL POWER BD 4 16" AZ 2 -300 -RI -XX PROVIDE CONTROL POWER