HomeMy WebLinkAboutPermit M16-0182 - SOLA SALON STUDIOS - ROOFTOP UNITSSOLA SALON S1'LIDIOS
351 STRANDER BLVD
M16-0182
City of Tukwila
' Department of Community Development
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206-431-3670
Inspection Request Line: 206-438-9350
Web site: http://www.TukwilaWA.gov
MECHANICAL PERMIT
Parcel No: 2623049064 Permit Number: M16-0182
Address: 351 STRANDER BLVD Issue Date: 1/19/2017
Permit Expires On: 7/18/2017
Project Name: SOLA SALON STUDIOS
Owner:
Name: REGENCY CENTERS LP
Address: PO BOX 790830 C/O PROPERTY TAX
DEPT, SAN ANTONIO, WA, 78279
Contact Person:
Name: LAMAR MOORE
Address: PO BOX 1455, MONROE, WA, 98272
Contractor:
Name: PRECISE HEATING & COOLING LLC
Address: PO BOX 1455, MONROE, WA, 98272
License No: PRECIHC8911-9
Lender:
Name:
Address:
Phone: (206) 510-4250
Phone: (206) 861-2525
Expiration Date: 6/29/2017
DESCRIPTION OF WORK:
INSTALL 4 NEW ROOFTOP UNITS, 3 TO GO ON EXISTING CURBS. INSTALL DUCT SYSTEM AND DIFFUSEERS TO
SERVE EVERY STUDIO WITH SUPPLY, RETURN AND EXHAUST.
Valuation of Work: $3,500.00 Fees Collected: $246.42
Type of Work: NEW Electrical Service Provided by: PUGEST SOUND ENERGY
Fuel type: GAS Water District: TUKWILA
Sewer District: TUKWILA
Current Codes adopted by the City of Tukwila:
International Building Code Edition:
2015
National Electrical Code:
2014
International Residential Code Edition:
2015
WA Cities Electrical Code:
2014
International Mechanical Code Edition:
2015
WAC 296-46B:
2014
Uniform Plumbing Code Edition:
2015
WA State Energy Code:
2015
International Fuel Gas Code:
2015
Permit Center Authorized Signature: Date: G "/
I hearby certify that I have read and examined this permit and know the same to be true and correct. All
provisions of law and ordinances governing this work will be complied with, whether specified herein or not.
The granting of this permit does not presume to give authority to violate or cancel the provisions of any other
state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this
development permit and agree tothe c nditions attached to this permit. %
Signature _ Date: 1 19
Print Name: �l (�Q K (J�(? 16* M
This permit shall become null and void if the work is not commenced within 180 days for the date of issuance, or if
the work is suspended or abandoned for a period of 180 days from the last inspection.
PERMIT CONDITIONS:
1: The attached set of mechanical plans have been reviewed by The Tukwila Fire Marshals Office and are
acceptable with the following concerns:
2: H.V.A.C. units rated at greater than 2,000 cfm require auto -shutdown devices. These devices shall be
separately zoned in the alarm panel and local U.L. central station supervision is required. (City Ordinance
#2437)
3: H.V.A.C. systems supplying air in excess of 2,000 cubic feet per minute to enclosed spaces within buildings
shall be equipped with an automatic shutoff. Automatic shutoff shall be accomplished by interrupting the
power source of the air -moving equipment upon detection of smoke in the main return -air duct served by
such equipment. Smoke detectors shall be labeled by an approved agency for air -duct installation and shall
be installed in accordance with the manufacturer's installation instructions. (IMC 606.1, 606.2.1)
4: Remote indicator lights are required on all above ceiling smoke detectors. (City Ordinance #2437)
5: Duct smoke detectors shall be capable of being reset from a single point near the alarm panel. (City
Ordinance #2437)
6: Duct detectors shall send a supervisory signal only upon activation. (City Ordinance #2437)
7: All new fire alarm systems or modifications to existing systems shall have the written approval of The
Tukwila Fire Prevention Bureau. No work shall commence until a fire department permit has been
obtained. (City Ordinance #2437) (IFC 901.2)
8: An electrical permit from the City of Tukwila Building Department Permit Center (206-431-3670) is required
for this project.
9: Contact The Tukwila Fire Prevention Bureau to witness all required inspections and tests. (City Ordinances
#2436 and #2437)
10: Any overlooked hazardous condition and/or violation of the adopted Fire or Building Codes does not imply
approval of such condition or violation.
11: These plans were reviewed by Inspector 511. If you have any questions, please call Tukwila Fire Prevention
Bureau at (206)575-4407.
12: Work shall be installed in accordance with the approved construction documents, and any changes made
during construction that are not in accordance with the approved construction documents shall be
resubmitted for approval.
13: All permits, inspection record card and approved construction documents shall be kept at the site of work
and shall be open to inspection by the Building Inspector until final inspection approval is granted.
14: Readily accessible access to roof mounted equipment is required.
15: All construction shall be done in conformance with the Washington State Building Code and the
Washington State Energy Code.
16: There shall be no occupancy of a building until final inspection has been completed and approved by
Tukwila building inspector. No exception.
17: Remove all demolition rubble and loose miscellaneous material from lot or parcel of ground, properly cap
the sanitary sewer connections, and properly fill or otherwise protect all basements, cellars, septic tanks,
wells, and other excavations. Final inspection approval will be determined by the building inspector based
on satisfactory completion of this requirement.
18: Every occupied space other than enclosed parking garages and buildings used for repair of automobiles
shall be ventilated in accordance with the applicable provisions of the International Mechanical Code.
19: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the
City of Tukwila Building Department (206-431-3670).
20: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila
Permit Center.
21: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an
approval of, any violation of any of the provisions of the building code or of any other ordinances of the City
of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other
ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction
documents and other data shall not prevent the Building Official from requiring the correction of errors in
the construction documents and other data.
22: ***MECHANICAL PERMIT CONDITIONS***
23: All mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila
Permit Center (206/431-3670).
24: Manufacturers installation instructions shall be available on the job site at the time of inspection.
PERMIT INSPECTIONS REQUIRED
Permit Inspection Line: (206) 438-9350
1400
FIRE FINAL
0703
MECH EQUIP EFF
1800
MECHANICAL FINAL
0609
PIPE/DUCT INSULATION
0705
REFRIGERATION EQUIP
0701
ROUGH -IN MECHANICAL
0702
SMOKE DETECTOR TEST
CITY OF TUKWILA
Community Development Department
(
ir"", Pc rnrit Censer
• 6.300 Southcenter Blvd., SOIC loll
Trrinvilo, W4 98188
htt /ww\v.Tukwila\l/A..;ov
Mechanical Permit No. tog—
Project No.
Date Application Accepted:
Date Application Expires:
(For o. jive use 0171y)
MECHANICAL PERMIT APPLICATION
Applications and plans mist be complete in order to be (accepted tl>r plan review.
Applications will not be accepted through the mail or by fax.
**please print**
SITE LOCATION
Kinn Co Assessor's Tax No.; 2623049064
Site Address: 351 Strander Blvd Suite Number:_ Floor:
Tenant Name: SOLA SALON STUDIOS New Tenant: ^0.....Yes El.. No
PROPERTY OWNER —
Name: Sola Salon Studios
Address: 50 South Steele Street, Suite 1050
City: Denver State: CO Zip: 80209
CONTACT PERSON — person receiving all project
communication
Name: LaMar Moore
Address: P.O. Box 1455 � �---------
City: Monroe Stab;: WA "Lip: 98272
Phone: (206) 510-4250 Fax:
Email: latnar@preciseheatandcool.corrt
MECHANICAL CONTRACTOR INFORMATION
Company Name: precise Heating and Cooling
Address: P.O, Box 1455
City: Monroe State: WA Zip: 98272
Pho"e: (206) 510-4250 Fax:
Contr Reg No.: PRECIHC891 L9 Exp Date: 06/27/2017
Tuk\vila Business License No.: BUS -0996560
Valuation of project (contractor's bid price):
Describe the scope of work in detail:
Install 4 New rooftop units, 3 to go on exising curbs. Install duct system and diffusers to serve every studio with supply, return, and
exhaust.
Use: Residential: New .......... ❑ Replacement ........ ❑
Commercial: New.......... Replacement........0
FueITr e: Electric..... V Gas....... V Other:.- --- _---------------_— - —_- ------
11 'App calions,Ponns. A pp hcalions On Lnw`2016 Apphcation Wchz cal Pennn Apph,lo- Rrcised 1-4- 16 docs
Revised January ?010 Page t of 2
bh
Indicate type of mechanical work being installed and the quantity below:
Unit Type
Qty
Furnace <I 00k btu
Residential, Nighttime
Furnace >I 00k btu
47
Floor furnace
Suspended/wall/Moor
mounted heater
40
Hood and duct_
Appliance vent
_
Repair or addition to
heat/refrig/cooling
system
_
Air handling unit
<10.000 cfm
4
Unit Type
Qty
Air handling unit
>I 0.000 c fm
Residential, Nighttime
C(va,orator cooler
47
Ventilation I1111
connected to simalc duct
Ventilation system
40
Hood and duct_
57 dB(A)
Incinerator — domestic
Commercial
Incinerator -----
comm/industrial
47 dB(A)
Unit Type
Qty
Fire damper
Residential, Nighttime
Di1'fIse r
47
rher,,,ostat ^--�
Wood/gas stove
40
I:;mergencv generator
57 dB(A)
Other mechanical
equipment
Commercial
57 dl3(A)
47 dB(A)
Boiler/Compressor Qty
0-3 lip/ 100.000 but
3-15 hp/500.000 but
15-30 lip/ 1.000.000 but
.30-50 hp/I,750,000 btu
50+ lip/1.750,000 btu
Noise:
Mechanical units need to be in compliance with the Titkwila Noise Code. Maximum permissible sound levels are based on From where the sound is
created and where the sound is heard. Additionally. if sound can be heard from within a house at night in a residential zone it may not be allowed.
For more details. see TMC 8.22
District of Sound
Producing Source
District of Receiving Property
Residential, Daytime*
Residential, Nighttime
Commercial
Industrial
Residential
55 dB(A)
45 dI3(A)
57 dB(A)
60 dB(A)
Commercial
57 dl3(A)
47 dB(A)
60 dB(A)
65 dB(A)
Industrial
60 d13(A)
50 dB(A)
65 dB(A)
70 dB(A)
*Daytime means 7AM-1011M, Monday through Friday and NAM -1011M, Saturday, sunaay ana state-recognizea nouaays.
A few sounds are exempt from the noise code. including:
Warning devices:
Construction and property maintenance during the daytime horn's (7am-10pm):
Testing of backup generators during the day.
PERMIT APPLICATION NOTES -
Value of construction — in all cases. a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject
to possible revision by the permit center to comply with Current fec schedules.
Expiration of plan review — applications R01- Which no permit is issued vvithin 180 days lollowing the date ol'application shall expire by limitation.
The building ollicial may grant one extension oftime for additional periods not to exceed 90 days each. The extension shall be requested in writing
and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition).
I IIF REBY CER -I IFY TI IAT I IIAVI_ READ AND EXAM INI'll) 'I Ii IS A13I11_ICATION AND KNOW THI_' SAME'10 13F. TRUE: UNDFIR
PENALTY 01' PERJURY BY TIII LAW'S 01 TI It: STA I F. OF WASHINGTON. ANI) 1 AM AUTI TORI/1_:D TO APPLY FOR THIS PERMIT.
BUILDING OWNEJ2 OR AUTHQAIZED A
Signature: IAV"- (.
Print Name: Kirk Offerdahl
Mailing Address:P.O. Box 1455'
I I.',Applicauons\Forms-Applleatons (hi Line'016 Apphcaiions.Mechwwal Perms Appbcannn Ke,u d I - .L In docc
Ke•+ised Januar• 2019
bl,
Day Telephone -
Monroe
City
Date: 12/05/2016
(425) 319-3428
WA 98272
State Zip
Page 2 o1'2
DESCRIPTIONS
ACCOUNT
QUANTITY
' 1
PermitTRAK
$246.42
M16-0182 Address: 351 STRANDER BLVD
Apn: 2623049064
$246.42
MECHANICAL
$236.94
PERMIT ISSUANCE BASE FEE
R000.322.100.00.00
0.00
$32.50
PERMIT FEE
R000.322.100.00.00
0.00
$157.05
PLAN CHECK FEE
R000.322.102.00.00
0.00
$47.39
TECHNOLOGY FEE
$9.48
TECHNOLOGY FEE
TOTAL FEES PAID BY RECEIPT: R9976
R000.322.900.04.00
0.00
$9.48
$246.42
Date Paid: Monday, December 05, 2016
Paid By: KIRK CIFFERDAHL
Pay Method: CREDIT CARD 09735G
IF
Printed: Monday, December 05, 20161:17 PM 1 of 1
��' I,�iSY57EM5
INSPECTION RECORD
Retain a copy with permit M)6 - 616
INVICTION NO. PERMIT NO.
CITY OF TUKWILA BUILDING DIVISION
6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-36
Permit Inspection Request Line (206) 438-9350
Project:
Type of Inspection:
Address:
351 44?
Date Called:
Special Instructions:
Date Wanted: m.
(g % % m.
Requester:
/—AMA -9
Phone No:
-/-0
14 Approved per applicable codes. EJ Corrections required prior to approval.
paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection.
p INSPECTION RECORD
lL� Retain a copy with permit Al Je ~ g2
INSPECTION NO. PERMIT NO.
CITY OF TUKWILA BUILDING DIVISION
6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670
Permit Inspection Request Line (206) 438-9350
Project:
Type of Inspection:
-Sou- SAL -OAU
1 TI Cr
Address:
Date Called:
35-1 57",OZI?
Special Instructions:
Hate Wanted:
,2 -22-17 p.m
Requester:
!./i'f' 4,01V7..—
Phone No:
20-25-6
nspector:
REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be
paid at 6300 Southcenter Blvd.. Suite 100. Catl to schedule reinspection.
INSPECTION RECORD
Retain a copy with permit I M)& -0
INSPECTION NO. PERMIT NO.
CITY OF TUKWILA BUILDING DIVISION
6300 Southcenter Blvd.., #100, Tukwila. WA 98188 (206) 431-3670
Permit Inspection Request Line (206) 438-9350
'ct: C j/p
PKM
J w�
T e of Inspection: /, ] �� ypp�
y 4 (rA04AAJ X4 L
Address:
351
Date Called:
Special Instructions:
Date Wanted: / a.m.
�Cv7 P.m.
Requester
Phone No:
11 Approved per applicable codes. LJ Corrections required prior to approval.
MENTS:
L
IInspector: 0 IUate:.2 —1(,P 17 I
REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be
paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection.
/ INSPECTION RECORD
( Retain a copy with permit 06 r 0/97ZINSPECTION N0. PERMIT N0.
CITY OF TUKWILA BUILDING DIVISION
6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670
Permit Inspection Request Line (206) 438-9350JMA�%VI-111
Project:
T e of Inspection
Address:Date
AA
Called:
Special Instructions:
.
Date Want .-1M-
16- /'r p.m.
;M16-11
Requeste ..
/41-449
Phone No:
2016 S" -lo q'2
Approved per applicable codes. LJ Corrections required prior to approval.
Inspector: Date:
REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be
paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection.
INSPECTION RECORD
Retain a copy with permit
INSPECTION NO. PERMIT NO.
CITY OF TUKWILA BUILDING DIVISION
6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670
Permit Inspection Request Line (206) 438-9350
Project:
Type of Inspection:
S'044
Aa11?h5;C4477 _AJ ,PAwlr
Address:
Date Called:
Special Instructions:
Date Wanted: a.m.
M.
Requester:
MYYKA
Phone No:
ab C@ ,57 7i * 2.5-6
Approved per applicable codes. LJ Corrections required prior to approval.
COMMENTS:
'W 14eOa1ey &) �niasz_4?9t3,AgD
Inspector: Date:
F1 REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be
paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection.
INSPECTION RECORD 1,04
Retain a copy with permifi
INSPECTION NO. PERMIT NO.
CITY OF TUKWILA BUILDING DIVISION
6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670
Permit Inspection Request Line (206) 438-9350
Project:
sant s q-�oN
Type of Inspection:
o1P7Ke11KV1o'1L
Address:
35/ -:5-1—A ofND,,Q BLVD
Date Called:
Special Instructions:
(ed
Date Wanted: m
P.m.
Requester:
Phone No:
0 Approved per applicable codes. LJ Corrections required prior to approval.
Inspector: K:C-e� Date — 1� —f /
REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be
paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection.
INSPECTION RECORD
Retain a copy with permit
INSPECTION: NUMBER PERMIT NUMBERS
CITY OF TUKWILA FIRE DEPARTMENT
206-575-4407
Project: /
f ection:
Type of?
Address:
Suite #:
Contact Person:
Special Instructions:
Phone No.:
Needs Shift Inspection:
Sprinklers:
Fire Alarm:
Hood & Duct:
Monitor:
Pre -Fire:
Permits:
Occupancy Type:
U $100.00 REINSPECTION FEE REQUIRED. You will receive an invoice from
the City of Tukwila Finance Department. Call to schedule a reinspection.
Billing Address
Attn: Company Name:
Address:
City: State: Zip:
Word/Inspection Record Form.Doc 3/14/14 T.F.D. Form F.P. 113
Precise Heatin & Coolin LL RECEIVE® AIR OUTLET — TEST REPORT
P.O. Box 1455 g g �I OF TUKWILA
Monroe Washington 98272 M- AR 0 6 2097
Phone: 206-510-4250
Project: SOLA SALON STUDIOS PERMIT CWEIRystem or Unit: VARIES - SEE OUTLET TYPE
Location 351 Strander Blvd, Tukwila 98188 Outlet Manufacturer:
AREA SERVED
No.
OUTLET
TYPE
SIZE
DESIGN
CFM
PREILIMINARY
CFM
FINAL
CFM
STUDIO
1
EG -2
8
70
100
70
STUDIO 2
2
EG -2
6
70
41
61
STUDIO 3
3
EG -2
8
140
123
129
STUDIO 4
4
EG -2
8
140
128
132
STUDIO 5
5
EG -2
8
140
126
125
STUDIO 6
6
EG -2
6
70
68
63
STUDIO 7
7
EG -2
6
70
83
68
STUDIO 8
8
EG -2
6
70
48
63
STUDIO 9
9
EG -2
6
70
55
58
STUDIO 10
10
EG -2
6
70
134
76
STUDIO 11
11
EG -2
6
70
127
62
STUDIO 12
12
EG -2
8
140
254
126
STUDIO 13
13
EG -2
6
70
100
75
STUDIO 14
14
EG -2
6
70
37
64
STUDIO 15
15
EG -2
6
100
48
95
STUDIO 16
16
EG -2
6
100
0
81
STUDIO 17
17
EG -2
6
70
0
59
STUDIO 18
18
EG -2
8
140
177
142
STUDIO 19
19
EG -2
8
70
35
61
STUDIO 20
20
EG -2
6
70
60
66
STUDIO 21
21
EG -2
8
70
43
60
STUDIO 22
22
EG -2
6
70
0
83
STUDIO 23
23
EG -1
6
70
86
69
STUDIO 24
24
EG -1
6
70
74
85
STUDIO 25
25
EG -1
6
70
122
64
STUDIO 26
26
EG -1
6
70
73
73
STUDIO 27
27
EG -1
6
70
91
74
STUDIO 28
28
EG -1
6
70
88
80
STUDIO 29
29
EG -1
8
140
138
139
STUDIO 30
30
EG -1
1 6
1 70
1 83
1 85
NOTES: TOTAL 2 EXHAUST SYSTEMS THROUGH THE BUILDING, SEE OUTLET TYPE FOR WHICH
CORRESPOND TO THE UNIT
T6EST DATE: 3/3/2017 READINGS BY: ASHLEY AVR-PASCUAL PA6), OF 2
t
Precise Heating & Cooling LLC
P.O. Box 1455
Monroe Washington 98272
Phone: 206-510-4250
Project: SOLA SALON STUDIOS
AIR OUTLET — TEST REPORT
H.V.A.C. System or Unit: VARIES - SEE OUTLET TYPE
Location 351 Strander Blvd, Tukwila 98188 Outlet Manufacturer:
AREA SERVED
No.
OUTLET
TYPE
SIZE
DESIGN
CFM
PRELIMINARY
CFM
FINAL
CFM
STUDIO 31
31
EG -1
6
70
87
85
STUDIO 32
32
EG -1
6
70
92
70
STUDIO 33
33
EG -1
6
70
93
80
STUDIO 34
34
EG -1
8
100
90
94
STUDIO 35
35
EG -2
6
100
0
77
STUDIO 36
36
EG -1
6
100
90
112
STUDIO 37
37
EG -2
6
70
0
76
STUDIO 38
38
EG -1
6
100
73
90
STUDIO 39
39
EG -2
6
70
0
73
STUDIO 40
40
EG -2
6
70
41
61
WOMENS ADA
41
EG -2
6
70
110
76
WOMENS #2
42
EG -2
6
70
130
73
WOMENS #1
43
EG -2
6
70
124
71
MENS
44
EG -2
6
70
108
72
LAUNDRY
45
EG -1
10
250
255
260
46
47
48
49
50
51
52
53
54
55
56
57
58
59
NOTES: TOTAL 2 EXHAUST SYSTEMS THROUGH THE BUILDING, SEE OUTLET TYPE FOR WHICH
CORRESPOND TO THE UNIT
TEST DATE: 3/3/2017 READINGS BY: ASHLEY AVRA-PASCUAL PAGE 2 OF 2
2012 Washington State Energy Code Compliance Forms for Commercial, Group R1, and > 3 story R2 and R3
D7 Q pz „ q �fA -1 au R1 Revised Sent 2015
LV IG QC C3 we i_n
Project info
I., .., .,,., I„ - ., .., ..,.,-.
Project Address: SOLA SALON STUDIOS
Date 12/15/2016
351 STRANDER BLVD
For Building Dept. Use
TUKWILA, WA 98188
Applicant Name: PRECISE HEATING AND COOLING
Applicant Address: P.O. BOX 1455, MONROE, WA, 98272
Applicant Phone 206-510-4250
HVAC Air Distribution System Schedule
List all HVAC systems that have the capability to provide heating and/or cooling to the spaces they serve.
Fan System ID
Speed Control
(Note 1)
System Total Fan Power
Nameplate HP Calculation
Description (Note 2) (Note 3)
AHU-1
CV
ROOFTOP AIR HANDLER 1.5
AHU-2
CV
ROOFTOP AIR HANDLER 1.5
AHU-3
CV
ROOFTOP AIR HANDLER 1.5
AHU-4
CV
ROOFTOP AIR HANDLER 1.5
Note 1 - Constant Volume (CV), Variable Air Volume (VAV), or Hospital/Lab CV system that qualifies for VAV budget per C403 ?_ 1Q.1 Exception 1.
Single zone VAV systems shall comply as CV.
Note 2- Enter the total nameplate hp of all fans associated with the delivery and removal of conditioned air by the system. Include all supply,
return/relief, exhaust and exhaust hoods (> 1 hp), make-up air, dedicated outside air (DORS), booster fans, and series fan -powered
terminals. VAV parallel fan powered terminals and economizer relief fans do not need to be included if the fans do not operate at peak
conditions.
Note 3 - Indicate if MECH-FANSYS form is required (Yes), or the system is not required to provide this information because it has a combined total
nameplate motor hp less than 5 hp (< 5 hp) or the system is ventilation only and thus has no heating or cooling capacity (No).
MECH-FANSYS Forms
A MECH-FANSYS form shall be provided for each system with total nameplate hp greater than 5 hp. Select Add
Fan System Form) to generate an additional form. Added forms can be deleted with button in cell E38 of t ad (F1 F
CORRECTION
LTR# - I L xwp L,
M1b**_016Z
CODE UUMFLIANUt
APPROVED
JAN 0 6 2017
City of Tukwila
BUILDING DIVISION
CITY OF TUK® ILA
DEC 30 2016
PERMIT CENTER
Unti tl ed
LOAD CALCULATIONS
PROJECT NAME- SOLA SALON STUDIOS
TOTAL BUILDING LOADS SUMMARY
sensible Latent -Total Heating
Clg BTUH Clg BTUH Clg BTUH BTUH
Roofs 7,703 7,703 25,333
walls 568 568 5,396
Partitions 1-0,400 1.0,400 20,800
windows 12,057 1.2,057 17,240
Equipment 2.04,574 204,574
Lighting 26,225 26,225
People 19,494 1.8,720 38,214
ZLatent 0 0
ventilation 40,583 5,991. 34,593 40,32.6
Infiltration 24 4 21 1-03
Perimeter Slab 8,930
Ducting 0 0 0
System Fans 0 0
Bldg. -totals 321,629 1.2,726 334,354 118,128
whole Building ZONE 1. of 1 LOAD SUMMARY
Zone Peak :July
Sensible
C1g BTUH
Roof
walls
Partitions
windows
Equipment
Lighting
People
ZL.atent
ventilation
Infiltration_
Perimeter Slab
zone Totals
T i me 1.400
Latent Total
C1 BTUH Clg BTUH
7,703 7,703 25,333
568 568 5,396
10,400 10,400 0
1.2,057 12,057 1.7,240
2.04,574 2.04,574
26,22.5 26,22.5
19,494 1.8,720 38,21.4
0 0
40,583 -5,991. 34,593 40,326
24 4 21. 1.03
321,629 1.2 , 726
SYSTEM 1 SUMMARY
Tons of cooling
System Name
Total cooling load
Total sensible cooling load
Ratio of sensible to total
Latent: Cooling Load
ventilation Air Mode
Ambient dry bulb temp.
Ambient vvet bulb temp.
Air Supply DSch. Mode
Supply Air CFM
Supply Air Dry Bulb Temp.
Supply Air wet Bulb Temp.
Supply Air Rel. Humidity
Supply Air Enthalpy btu/lb
REVIEWED FOR
E COMPLIANCE
APPROVED
Hea i ng JAN 0 6 2017
BT H
City of Tukwila
BUILDING DIVISION
rORRECTION
LTR#IV---
8,930
334,354 1181
RECEIVED
CITY OF TUK0LA
27.9
UN111.
334,354
321,629
0.962
12,72.6
Ambient Air
86.0
66.0
Temp f=ixed
12,853
55.0
53.9 `
93.3
23. .1.3
Page 1
DEC 30 2016
PERMIT CENTER
. / Outside ventilation
[oil Inlet Dry bulb
[oil Inlet wet bulb
system heating load
Untitled
air cfm 3'354
temp. 77.24
temp. 63.63
1I8,I20
Page 2
I
SHUTLER
— CONSULTING
ENGINEERS, Inc.
12503 Bel -Red Road, Suite 100
Bellevue, Washington 98005
(425) 450-4075 FAX (425) 450.4076
STRUCTURAL CALCULATIONS FOR:
NEW & REPLACEMENT HVAC UNITS
--
SOLA SALON
351 STRANDER BLVD.
TUKWILA, WASHING'T'ON
PROPOSED BY:
PRECISE HFATING &COOLING
PO BOX 1455
MONROE, WA 98272
(206) 51.0-4250
JOB Sola Salon
SHEET NO. COVER OF
CALCULATED BYjch DATE 12/29/2016
CHECKED BY DATE_
SCALE _
JOB NUMBER 16-01.89
$ ? . EVIEWED FOR
'—LOCHE COMPLIANCE
..
. QPROVED
JAN 0 6 2017
I
�.....
DESIGN CRITERIA: Ci fv
of Tukwila
BUILDING DIVISeC)INI
CODE .................................. INTERNATIONAL BUILDING CODE, 2015 EDITION
ROOD LIVE LOAD ................. 25 PSP SNOW LOAD, Is=1.0
WIND L,OAD......................... 110 MPH ZONE, EXPOSURF,'B', Iw-1.0
SEISMIC ZONE ..................... SITE CLASS 'I)', Sds 0.972, ap=2.5, Rp=6.0, Ip -1.0
CORRECTION
LTR #_I_
m 16*1- 0 1 94z
RECEIVED
CITY OF TtUKWILA
DEC 30 2016
PERMIT CENTER
AM O SHUTLER
® CONSULTING
ENGINEERS Inc.
12503 Bel—Red Road, Suite 100
Bellevue, Washington 98005
(425)450-4075 FAX: (426)450-4076
0
HEj JoB SOLA SALON
�E WASI� C9 Tukwila, Washington
_, ?G' �' SHEET NO SKS-1Nr OF
CALCULATED BY JH DATE 12-28-16
SCALE NOTED Job No• 16-01.89
31757
'RFs JOR A L
s�aNA L
A0'_n"
e n'_n"
PARTIAL ROOF FRAMING PLA
•SCALE±: , YB"=1'-0"
NOTES: 1) VERIFY EXISTING COND TONS,� DIMENSIONS INy; T14F RELD
NOTIFY ENGINEER OF brFEE�EN'CES,
2) FOUR UNITS TO DE INSTA`i~.LE1• — �PI_A'CE ONLY,"UNE UNIT ON
ANY JOIST.
C
m
> s
A SHUTLERrr_17"l
H Eq
®� ® CONSULTINGW AS11
®®® ENGINEERS Inc.,�,
12503 Bel—Red Road, Suite 100 �" "' •�G .
Bellevue, Washington 98005 , �
(425)450-4075 FAX: (425)450-4078 1757OR L
NA L
JOB SOLA SALON
Tukwlla, Washington
SHEET NO SKS-2 OF
CALCULATED BY JH DATE 12-28-16
SCALE NOTED Job No. 16-01.89
SECTION A/SKS-2.
SCALE; 3/a'=1'-0"
SHUTLER
®®® CONSULTING
ENGINEERS Inc.
12503 Bel -Red Road, Suite 100
Bellevue, Washington 98005
425)450-4075 FAX: (425)450-4078
TRUSS PER
PLAN (TYP.)
✓�' WASIllu
Baa/
357
s17
I4AL
►L6NA L EAG\
11
Joe SOLA SALON
Tukwila, Washington
SHEET NO SKS-3 OF
CALCULATED BY JH DATE 12--28-16
SCALE NOTED Job No. 1601.89
uvnr i "IIT &
__R PLAN
SECTION-, B/SKS-3.
SCALE: 3/4"=1'-0"
SCREWS
SIDE 12
"CREWS
SIDE 12
0D 200
v/6•-# 10x3°
;CREWS (TYP.)
SHUTLER
CONSULTING
ENGINEERS, INC
12503 Bel -Red Rd., Suite 100
Bellevue, WA 98005
(425) 450-4075
FAX (425) 450-4076
SHF.F1 NO._-._-- --.---�1 -- --- OF
CAI_CULATFD BY
DATE.
SCAI_F:
I
1
•
t
• I � --
T
;
I
O SHUTLER
CONSULTING
ENGINEERS, INC
12503 Bel -Red Rd., Suite 100
Bellevue, WA 98005
(425) 450-4075
PAY ld')Cl Arn_A(M;
JOB
SHEET NO.. — --- -- - OF...- --
CALCULATED BY �/ ` D✓/�--_
DATE-_...� / 4ll ---- _.
SCALE
w
00,
1
...
OF)
_
Vj
1. .
---
t�
--
,
-
1
- - -
Qs
__i--
t
��-6f
-
-
- _ -
-,--
ti
AMAMMIMM SHUTLFR
NMUNIMM CONSULTING
ff"'"MM ENGINEERS, INC
12503 Bel -Red Rd., Suite 100
Bellevue, WA 90005
(425) 450-4075
FAX (425) 450-4076
JOB
SHEF1 NO
CALCULATED 13Y 1-fO
DATE / 9, - Y4� .1 �
SCALE
OF
Aq-
A-
-z-
aj-
U
-Atal
8HUTLB0
MMM11=11 CONSULTING
§�W--------ENGINEERS, INC
12503 Bel -Red KJ,Suite 10O
Bellevue, \w&9u0O5
(425) 450-4075
FAX (4%5)4GO'4O76
Joo–_____ SHEET NO.
�
'-------'--- - —
nmCuLAr onv
moe.'__�_-Lx��z�9���l��_�-__-___----__-____'
12�477
-5 -
Roof Toa HVAC Unit - lateral loads
Seismic - Sds 0.972 ap 2.5
Sd, 0.544 RP 6.0
Ip 1.0
Fp 0.486 wt
Wind - Speed
110
inph
KZ
0.70
Exposure
B
K,
1.00
Kd
0.85
q
18.43
psf
I
1.00
i
Fp - ws
21.0
psf
GC, - horiz.,
1.90
Fv - ws
- _
16.6
psf
GC, - vert.
1.50
I
i
I
I
r
Design Maps Summary Report
lrttp://eaithduake.usgs.gov/desigumaps/us/sumnlary.php?templdiel m...
E,MS Design Maps Summary Report
User -Specified Input
Building Code Reference Document 2012/2015 International Building Code
(which utilizes OSGS hazard data available in 2008)
Site Coordinates 47.460N, 122.26°W
Site Soil Classification Site Class D - "Stiff Soil"
Risk Category I/II/IIT
t {
a.
lz t 3 Ike n t �f►11i kS 1'4*P1fi. t� °.
USGS-Provided Output }�
Ss = 1.459 g SMS = 1.459 g S„y = 0.972 g
Sl = 0.544 g SM1 = 0.816 g Sol = 0.544 g
For Information on how the SS and S1 values above have been calculated from probabilistic (risk -targeted) and
deterministic ground motions In the direction of maximum horizontal response, please return to the application and
select the "2009 NEHRP" building code reference document.
MCEa Response Spectrum Design Response Spectrum
1.65 1.10
1.50 1.00
1.35 0.90
1.20 0.80
1.05 0.70
a' 0.90 dJ 0.60
M
V�pp
O75--------- --- - - - __._.._ .. .
0.60 0.40
0.45--0.30
0.30 0.20--
0.15.- 0.10
0.00f -i i F- i 0.00 1
0.00 0.20 0.40 0.60 0.90 1.00 1.20 1.40 LGO 1.00 2.00 0.00 0.20 0.40 0.60 0.80 1.00 1.20 1.40 1.60 1.00 2.00
Period, T (sec) Period, T (sec)
Although this Information is a product of the U.S. Geological Survey, we provide no warranty, expressed or implied, as to the accuracy of
the data contained therein, This tool Is not a substitute for technical subject -matter knowledge.
I of 1 12/24/2016 12.:13 PM
T
MYORK'
SUBMITTAL DATA
For: Quotation
Order #: Date: 10/28/2016
Project: SOLA
Project #: NN10281606
Location:
Purchaser: PRECISE-LAMAR
Submitter: YORK -NOAH
Unitary Sales loos vt 5.9.0
mr
(qm- , 6 ___ I - , a z
Infonnation is subject to change without notice Check local codes.
REVIEWED FOR
CODE COMPLIANCE
APPROVED
JAN 0 6 2017
City of Tukwila
BUILDING DIVISION
RECEIVED
CITY OF TUKWILA
DEC 0 5 2016
PERMIT CENTER
Printed 10/28/2016
a
Date
10/28/2016
Project Name WYORK
"
SOLA
Project Number
N N 10281606
Client I Purchaser
PRECISE-LAMAR
Submittal Summary Page
Qty Tag # Model #
JZXG08D4B3AA2B111A2
Description
3 5 WKS-
7.5 Ton, Two Stage Cooling, York Direct Fit Single Packaged R -
FACTORY
410A Air Conditioner, 11.0 EER / 11.5 IEER, 125 Mbh Two Stage
BLD
Input Low Heat Aluminized Gas, Gas Heat, 460-3-60
• VFD IntelliSpeed
• Dry Bulb Economizer (Downflow only) (with Barometric Relief) with
Economizer Fault Detection & Diagnostic (Meets ASHRAE 90.1-
2013, IECC 2015, California Title 24, AMCA 511)
• Medium Static Belt Drive Blower
• Simplicity® SE Controller including Discharge Air, Return Air, and
Outdoor Air Temperature Sensors
• Return Air Smoke Detector
• Microchannel All Aluminum Condenser Coil, Copper
tube/Aluminum fin Evaporator Coil
3 2PM04700224
Phase Monitor Kit
1 ZE060H12B4C1EAA1A1
Single Stage Cooling, York Small Sunline Single Packaged R -410A
Air Conditioner, 5 Ton, 11.8 EER / 14.0 SEER, 125 MBH Input,
Single Stage Gas Aluminum Steel, 460-3-60
• Dry Bulb Economizer and Hood (No Barometric Relief Damper)
with Economizer Fault Detection & Diagnostic (Meets ASHRAE
90.1-2013, IECC 2015, California Title 24, AMCA 511)
• 1.5 HP Standard Static Belt Drive Blower
• 1" Throwaway Filters
• SimplicityO SE Controller including Discharge Air, Return Air, and
Outdoor Air Temperature Sensors
• Return Air Smoke Detector
• Microchannel All Aluminum Condenser Coil, Copper
:
tube/Aluminum fin Evaporator Coil
• Galvanized Steel Drain Pan
• Standard Access Doors
1 1 RD0410
Barometric Relief Damper with Hood Kit (Downflow Unit or Duct
Mounted)
1 1 RC0434
Roof Curb - 14" High, Flat, Uninsulated, Full Perimeter (Shipped
Knocked Down)
►J,
Equipment start-up and commioning by a factory Haired technicrn is recommended.
Contact your supplying distributor of sales representatMe for additional information & guidance.
4 'i i,
Unitary Sales 1'001 v1 5 9 0 Information is • ubjad In change without notice CheCk local codes Printed 101812016
vw�YORK"
Project Name: SOLA —
Quantity: 3 Tag #: 5 WKS -FACTORY
BLD
Cooling Performance
�otal gross capacity
Sensible gross capacity
Total net capacity
Sensible net capacity
Efficiency (at ARI)
Integrated eff. (at ARI)
Ambient DB temp.
Entering DB temp.
Entering WB temp.
Leaving DB temp.
Leaving WB temp.
P^wer input (w/o blower)
(S xlnd power___.
Refrigerant
Refrigerant type
Sys1
_§ S2
Direct Fit (3-12.5 Ton — - Page:3
Package) L526
Single Package R-41 OA Air Conditioner
Unit Model #: ZXG08D4B3AA2B111A2
-- — --- ---- — —' System: ZXG08D4B3AA2B111A2 (3)
94.9 MBH
67.4 MBH
90.0 MBH
62.5 MBH
11.00 EER
13.10 IEER
95.0 °F
80.0 °F
67.0 'F
f
59.2 F I r
57.0 °F
G.63 kW��
84 dB(A)
R -410A
4 lbs 8o/ ; ►
4 lbs 12 oz
Gas Heati_ng Performan_ ce
17,5 Ton
Entering temp.
60
I
,Heating output capacity (Max)
output
M
100 MBH
All units are manufactured at an ISO 9001 registered facility and each
9 Y
Supply air
3000 CFM
I rooftop is completely computer -run tested prior to shipment.
Heating input capacity (Max)
125 MBH
! Unit Features
Leaving DB temp.
1 Air temp rise
90.9 `F
30.9 +
Two Stage Cooling
SSE
80.0 %
125 Mbh Two Stage Input Low Heat Aluminized Gas
Stages
2
• Full perimeter base rails with built in rigging capabilities
Supply Air Blower Perform_ a_ nce
i • Either supply and/or return can be field converted from vertical to horizontal
-- - —
Supply air
3000 CFM
configuration without cutting panels.
Ext. static pressure
0.6 IWG
• Unit Cabinet Constructed of Powder Painted Steel, Certified At 1000 Hours
Addl. Unit Losses (Options/Accessories)
0.17 IWG
Salt Spray Test (ASTM B-117 Standards)
Blower speed
815 RPM
. Scroll Compressors
Max BHP of Motor (including service factor)
2.90 HP
. Dry Bulb Economizer (Downflow only) (with Barometric Relief) with
Duct location Bottom
Motor rating
2.90 IIP
Economizer Fault Detection & Diagnostic (Meets ASHRAE 90.1-2013, IECC
• Actual required BHP
1.56 1 iP2.015.
California Title 24, AMCA 511)
Power input
1 44 kW
Medium Static Belt Drive Blower
F.,IevaUon
0 ft1
• Replacement filters: 4 - (16" x 20"). Unit accepts 2" wide filter
' tDrive type BF.L.T
; . Solid Core Liquid Line Filter Driers
Electrical Data _ _
• Unit Ships with 2" Throwaway Filters with a Standard Filter Rack that will
Power supply 460-3-60
Accept up to 4" Filters
Unit min circuit ampacity
20.4 Amps
I • Short Circuit Current: 5kA RMS Symmetrical
Unit min over -current protection
Unit max over -current protection
25 Amps
25 Amps
Single Point Power Connection
—_ _ v
DimenSipnS &Weight
• Microchannel All Aluminum Condenser Coil, Copper tube/Aluminum fin
Evaporator Coil
Hgl 41 in. Len 87 in. Wth
Weight with facto installed options
62 in.
963 lbs.
I BAS Controller
Clearances
Simplicity SE Controller including Discharge Air, Return Air, and Outdoor Air
Temperature Sensors
Right 18 in. Front 48 in. Back
in.
Standard Unit Controller: Simplicity SE Control Board
P y
� fop _72 in. Bottom. - 1 in. Left _
t 12 2 in. J
I Note. Please refer to the tech guide for listed maximums tatic
pressures
Safely Monitoring - Monitors the high and low-pressure switches, the
freezestats, the gas valve, if applicable, and the temperature limit switch on
AMERICAN .i'� �/
gas and electric heat units. The unit control board will alarm on ignition
failures, safety lockouts and repeated limit switch trips.
��---�us- = r.
An Inte rated Low -Ambient Control Anti -Short C de P t t L d L
I
unitary Sales Tool 0 5 9.0
V y Dr- ec ion, ea - ag,
Fan On and Fan off Delays, Low Voltage Protection, On -Board Diagnostic
and Fault Code Display. Allows all units to operate in the cooling mode down
to 0'F outdoor ambient without additional components or intervention.
Warranty
• One (1) Year I imited Warranty on the Complete Unit
• Five (5) Year Warranty - Electric Heat Element
• Five (5) Year Warranty - Compressors
• Ten (10) Year Warranty - Aluminized Steel Tubular Heat Exchangers
i
Information s subject is rhanoo without roliro Check local nodes. Printed 1012812016
Project Name: SOLA
Quantity: 3 Tag #: 5 WKS -FACTORY
BLD
Direct Fit (3-12.5 Ton Page:4
Package) L526
Single Package R-41 OA Air Conditioner
Unit Model #:-ZXG0804133AA26111A21
System: ZXG08D4B3AA2B111A2 (3)
Factory Installed Options
ZXG08D4B3AA2B111A2
Product Category:
Heat Type:
Nominal Cooling Capacity:
Heat Size:
Voltage:
Airflow:
Airflow Options:
Coil Options:
Controls:
Sensor Options:
Economizer / Damper:
Convenience Outlet:
Electrical Options:
Cabinet Options:
Special Options:
Product Generation:
• 2PM04700224 - Phase Monitor Kit
(1.0 lbs)
Unitary Sales Tool 0.5 9.0
York Direct Fit Single Packaged R -410A Air Conditioner
Gas Heat
7.5 Ton
Two Stage Cooling
11.0 EER / 11.5 IEER
125 Mbh Two Stage Input Low Heat Aluminized Gas
460-3-60
Medium Static Belt Drive Blower
VFD IntelliSpeed
Microchannel All Aluminum Condenser Coil, Copper
tube/Aluminum fin Evaporator Coil
Simplicity® SE Controller including Discharge Air, Return
Air, and Outdoor Air Temperature Sensors
Return Air Smoke Detector
Dry Bulb Economizer (Downflow only) (with Barometric
Relief) with Economizer Fault Detection & Diagnostic
(Meets ASHRAE 90.1-2013, IECC 2015, California Title
24, AMCA 511)
Field Installed Accessories
Information is subject to change without notice. Check local codes.
Printed 1012812016
0
Q)
0)
r� T
< t_17
Wni N
<
r� T
Wni N
<
co
23 6
ww
cq
0 K Direct Fit (3-12.5 Ton Page:6
R Package) L526
Single Package R -410A Air Conditioner
Project Name: SOLA J— Unit Model #: ZXG08D4B3AA26111A2
Quantity: 3 Tag #: 5 WKS -FACTORY — System ZXG08D4B3AA2B111A2 (3)
BLD
XX12E Field Installed Accessory
Unit Accessory Weights
Unit Accessory
Weights (lbs.)
Vertical Flow Dry Bulb Economizer Small Footprint
63
orizontal Flow Dry Bulb Economizer Small Footprint Short
96
orizontal Flow Dry Bulb Economizer Small Footprint Short
75
orizontal Flow Dry Bulb Economizer Small Footprint Tall
81
lorizontal Flow Dry Bulb Economizer targe Footprint Short
105
-lorizontal Flow Dry Bulb Economizer Large Footprint Tall
102
ower Exhaust Vert Flow Small Footprint —
38—
ower Exhaust Vert Flow Large Footprint
ower Exhaust Horiz Flow Small Footprint
38
_ 38
ower Exhaust Horiz Flow Large Footprint—'
38
ail Guard Kit Small Short Factory Installed
19
-fail Guard Kit Small Tall Factory Installed
--
24
ail Guard Kit Large Short Factory Installed
50
ail Guard Kit Large Tall Factory Installed
50
Curb Rigid 14" Small Footprint —
Curb Rigid Rigid 24" Small Footprint — —�
145
135
.urb Rigid 14" Large Footprint — —
J�135
'urb Rigid 24" Large Footprint
135
Unitary Sales Tool v1.5.9.0 Information is subject to change without notice. Check local codes. Printed 10/28/2016
i�YORK
Small Sunline (3-6 Ton
Package) N543
Single Package -R-410A Air Conditioner
Project Name: SOLA
-
60 °F
� ----_-
Quantity: 1
-----^
_—-----A_--_C_ooling_P_e_rf_orman_c_e_—_-_---_---_-_---\
2.000 CFM
Total gross capacity
61.1 MBH
Sensible gross capacity
45.4 MBH
Total net capacity
57.3 MBH
Sensible net capacity
41.6 MBH
Seasonal Efficiency (at ARI)
14.00 SEER
Efficiency (at ARI)
11.80 I-EIR
Ambient DB temp.
95.0 °F
Entering DB temp.
80.0 °F
Entering WB temp.
67.0 `f-
Leaving DB temp.
59.0 °F
Leaving WB temp.
57.3 °F
Power input (w/o blower)
4.2.8 kW
Sound power --- ------------ - -
„---82 dBA)
Refrigerant
Elevation
R_efrigeerant type _ _
R-41 OA
Gas Heating Performance
Electrical Data
----- ----
Entering DB temp.
60 °F
Heating output capacity (Max)
100 M13H
Supply air
2.000 CFM
Heating input capacity (Max)
12.5 M13H
Leaving DB temp.
106.3 °F
Air temp. rise
46.3 °F
SSE
80.6 %
Stages -- -- - ---- --
-- 1
- --- -
Supply Air Blower Performance
Supply air
2000 CFM
Ext. static pressure
0.6 IWG
Addl. Unit Losses (Options/Accessories)
0.15 IWG
Blower speed
1151 RPM
Duct location
Bottom
Motor rating
1.50 HP
Actual required BHP
1.19 HP
Power input
1,11 kW
Elevation
0 ft.
Drive type _ — _ ____BELT_
Electrical Data
----- ----
-----
Power supply
460-3-60 -----
Unit min circuit ampacity
14.1 Amps
Unit max over -current protection _ _ _
- 20 Amps
__ _ Dimensions & Weight
_
Hgt 33 in. Len 83 in Wth
45 in.
Weight with factory installed options
699 lbs.
Clearances
Right 24 in. Front 32 in.
Back
36 in.
To 72 in. Bottom 0 in.
Left_
36 in.__J
_ _
Note: Please refer to the tech guide for listed maximum
static
pressures
AMf01CAN�
V
� Got
unitary Sales Tool 0.5.9.0
age: 7
Unit Model #: ZE060H12B4C1EAA1A1
System: ZE060H12B4C1EAA1A1
5 Ton
• York Units are Manufactured at an ISO 9001 Registered Facility and Each
Rooftop is Completely Computer -Run Tested Prior to Shipment.
Unit Features
• Single Stage Cooling
• Single Stage Coaling
• Single Stage Gas Aluminum Steel
• 125 MBH Input
• Unit Cabinet Constructed of Powder Painted Steel, Certified At 1000 Hours
Salt Spray Test (ASTM B-117 Standards)
•° Full Perimeter Base Rails with Built in Rigging Capabilities
• Either Supply and/or Return can be Field Converted from Vertical to
Horizontal Configuration without Cutting Panels.
• Scroll Compressor
• Dry Bulb Economizer and Hood (No Barometric Relief Damper) with
Economizer Fault Detection & Diagnostic (Meets ASHRAE 90.1-2013, IECC
2015, California Title 24, AMCA 511)
• 1.5 HP Standard Static Belt Drive Blower
• Unit Ships with 1" Throwaway Filters with a Standard Filter Rack That Will
Accept up to 2" Filters
• Solid Core Liquid Line Filter Driers
• Single Point Power Connection
• Short Circuit Current: 5kA RMS Symmetrical
• Through -the -Curb and Through -The -Base Utility Connections
• Return Air Smoke Detector
• Microchannel All Aluminum Condenser Coil, Copper tube/Aluminum fin
Evaporator Coil
• Galvanized Steel Drain Pan
• Standard Access Doors
Standard Unit Controller: Simplicity Control Board
• An Integrated Low -Ambient Control, Anti -Short Cycle Protection, Lead -Lag,
Fan On and Fan off Delays, Low Voltage Protection, On -Board Diagnostic
and Fault Code Display. Allows all units to operate in the cooling mode down
to 0 °F outdoor ambient without additional components or intervention.
• Safety Monitoring - Monitors the High and Low -Pressure Switches, the
Freezestats, the Gas Valve, if Applicable, and the Temperature Limit Switch
on Gas and Electric Heat Units. The Unit Control Board will Alarm on Ignition
Failures, Safety Lockouts and Repeated Limit Switch Trips.
BAS Controller
• Simplicity SL Controller including Discharge Air, Return Air, and Outdoor Air
Temperature Sensors
Warranty
• One (1) Year Limited Warranty on the Complete Unit
• Five (5) Year Warranty - Compressors and Electric Heater Elements
• len (10) Year Warranty - Aluminized Heat Exchanger
Information is subject to change wilhout nett(.(' Check local codes.
Printed 10/28/2016
c�
Kit 2 "am YO R K `
Project Name: SOLA
Quantity: 1
Small Sunline (3-6 Ton T Page:8
Package) N543
Single Package R -410A Air Conditioner
--Unit #: Model ZEO60H1264C1EAA1A1
_.el #: - -•---------• A -- -
System: ZE0601-112134C1EAAW
Factory Installed Options
ZE060H12B4C1EAA1A1
Field Installed Accessories
1 RD0410 - Barometric Relief
Damper with Hood Kit (Downflow
Unit or Duct Mounted) (6.0 lbs)
0 1 RC0434 - Roof Curb - 14" High,
Flat, Uninsulated, Full Perimeter
(Shipped Knocked Down) (86.0
lbs)
Unitary Sales lool v1.5 9.0 Information is sublect to change without nolice, Check local codes. Printed 1 012 812 0 1 6
I
York Small Sunline Single Packaged R-41 OA Air
Product Category:
ZE
Conditioner
11.8 EER / 14.0 SEER
060
Nominal Cooling Capacity:
Single Stage Cooling
5 Ton
Heat Type and Nominal Heat Capacity:
Single Stage Gas Aluminum Steel
125 MBH Input
H12
B
Airflow Options:
1.5 HP Standard Static Belt Drive Blower
Voltage:
460-3-60
4
Dry Bulb Economizer and Hood (No Barometric Relief
Economizer I Damper:
C
Damper) with Economizer Fault Detection & Diagnostic
(Meets ASHRAE 90.1-2013, IECC 2015, California Title
24, AMCA 511)
Sensor Options:
E
Return Air Smoke Detector
Controls:
Simplicity® SE Controller including Discharge Air, Return
Air, and Outdoor Air Temperature Sensors
A
A
Refrigeration:
Microchannel All Aluminum Condenser Coil, Copper
tube/Aluminum fin Evaporator Coil
Additional Options:
1
1" Throwaway Filters
A
Cabinet Options:
Galvanized Steel Drain Pan
Standard Access Doors
Product Generation:
1
Field Installed Accessories
1 RD0410 - Barometric Relief
Damper with Hood Kit (Downflow
Unit or Duct Mounted) (6.0 lbs)
0 1 RC0434 - Roof Curb - 14" High,
Flat, Uninsulated, Full Perimeter
(Shipped Knocked Down) (86.0
lbs)
Unitary Sales lool v1.5 9.0 Information is sublect to change without nolice, Check local codes. Printed 1 012 812 0 1 6
IM
Lo
Z
V
O
I � C
A O
Q
Q
'C Y
�✓ R
a.
I'y�wJ
' I
�
cY
I
I I
a
al
a
M oo•
I
._.
I
� 1
I
ry m
.. V
w
m` m•
LU
14
O .� v
V' ✓, a0 V �n .0 .n n ap ap .p ,n in an
r
't
m
m
O
N
N
o
' a
N
C
O I
'
O
O
I.
N
N
4)
•-, .-, .y . � ., r � r. ., , 1 . 1 , . , , , .
'O V)
F -O
V ti m
I
I
H
L
IM
Lo
Z
V
O
I � C
A O
Q
Q
'C Y
�✓ R
a.
I'y�wJ
' I
I I
�
cY
I
I I
M M
M
rvry ��
O
M oo•
I
._.
I
� 1
I
ry m
.. V
.o
m` m•
i
14
O .� v
V' ✓, a0 V �n .0 .n n ap ap .p ,n in an
�!j
N J �
O
O
o
' a
N
,
I.
•-, .-, .y . � ., r � r. ., , 1 . 1 , . , , , .
00
F -O
V ti m
O
- -
H
M n
m .. .-, _ - gym' MV .- -,
_—._
_• I
�
I I
�
cY
I
I I
M M
M
rvry ��
O
M oo•
I
._.
I
� 1
I
ry m
.. V
li
i
14
O .� v
V' ✓, a0 V �n .0 .n n ap ap .p ,n in an
�!j
N J �
O
O
o
' a
N
,
I I
�
cY
I
I I
rvry ��
M oo•
I
._.
I
� 1
I
ry m
.. V
li
VU
1 Q m
,ri •��. �,. .. , � - I I I L7 Q 'ins f.'
m
Q . To'.
m i ry
n V m> (3
3
3
, U
I � QCJ ✓, 1-U vKJ_
I NN rin'ln >f
I ., Z �. iil ..iQ-�QVNi rvtiV
.. pan pan .1, .n000J v, r / yt I -� I
� >o`mmcnv
N
v,zr-
a.na.nrvryrvma>-n.n .�-a o.Qi,c• Z3 "I
o v, f a c cjm Jns i o - X
46
O
ro
O m
V 9
O
C
Z
O
�
li
i
14
m
Fin
I
t_ z
� Z
w O
o
,
O
a
m
K
Project Name: SOLA
Quantitv: 1
Small Sunifine (3-6 Ton
Package) N543
Single Package R -410A Air Conditioner
Unit Model #
System
Typical Application
Page- 10
ZE0601-1112134C11EAAW
ZE060H12B4C1EAA1A1
FIELD -SUPPLIED
DISCONNECT SWITCH
I TO WN I HOL VVNINU
POWER TO INDOOR
SUPPLY THERMOSTAT
Unitary Sales Tool v1S.9,0
RETURN AIR
DUC11,
Information is subject to change w0hout notice. Check local codes.
TO GAS SUPPLY LINE
N
Printed 10128/2016
MYORKSmall Sunfine (3-6 Ton Page: 11
�' Package) N543
Single Package R -410A Air Conditioner
Project Name: SOLA Unit Model #: ZE060H12I34&1EAA1A1
Quantity: 1 System: ZE0601112134C1EAMA1
Typical Field Power and Control Wiring
TYPICAL POWER WIRING
LUG
REFER ELECTRiCA1. DATA
TABLES TO SIZE THE DISCONNECT
SWITCH OVIRCURRENT
PROTECTION ANDA'IRING
CONTACTOR
FIELD -SUPPLIED
DISCONNECT
L -----------i-
I C} - r- THREE
L------------I--Q.^¢_ PHASE
GROUND L - - - - - - - - - - - - - - - J_ -a
LUG O__ > POWER
L SUPPLY
TYPICAL COOL/HEAT CONTROL WIRING
COOLING ONLY (24 VOLT THERMOSTAT) COOLING / HEATING (24 VOLT THERMOSTAT)
THERMOSTAT' UNIT TERMINAL THERMOSTAT'
TERMINALS STRIP T61 TERMINALS
UNIT TERMINAL
ISH STRIP STRIP TBI
24 VOLT ADD
C .. ...............
TRANSFORMER JUMPER .. ......... .... ..
U12' C ) - -------------- -- 24 VOLT
TRANSFORMER
ccn,) . . ................ _0
C, (AD - -------------- -110,
'24 VOLT THERMOSTAT TO CONTROL Ot,!
ECOMIZER ON SECOND 0-
S FACE COOLING USE A 2 STAGE COOLING THEIRNIOSTAT @ I
COOLING / HEATING (ELECTRONIC THERMOSTAT)
MULTI STAGE
THERMOSTA I
TERMINALS UNIT TERMINAL
ADD RC STRIP TE11 21 VOLT
JUMPER PH --------------------- R TRANSFORMER
Y1------------------- Y1
Y2 ---------- 2 ------- Y2
Vy 1 ......... ...... W 1
4 1V2 -'_-----'3 ------- N2
LEDI ---------------------
LF D 2 NOT
- ------------
SED
4
ADD Al
JUMPER A2
TO RENIO T E SENSOR
il IF USED
ELECTRON:C PROGrANIMABLE THERN4j°7AI TYF CAL
SECOND STAGE COOLING S NOT REOU PEP ON UN IS LES` E-,QNOf.I 'Ff,,
SECOND STAGE HEA1:NG S ONLY RLOU PEE) tUN I IN T, V, IH A Pv),;Q!,]A,,;E
ELECTR C HEATER -')R: STA,",E GA:z HEAT
• REMOVE JUMPER J2 FROMTERMINALS 4 AND C; ON JI PLUG CONNECTOR
PC ON UNITS WITH ECONOM..ZER TERN'INALS A] AND A2 PROVIDE A RELAY
OUTPUT TO CLOSE THE OUTDOOR ECONOMIZER DAMPERS WHEN THE
I
.HE RISIAI TO THE SEI -BACK POSI I ION
24 VOLT TH.ERNIOSTAT Tn CONTROL TrE ECONOMIZER ON THE SECOND
STAGE" COCILINC, OR TO eAVE AN ELECTRIC HEAT ACCESSORY VvtTH Tv,,O
5TAC;_:S0"-,7_Af jSF A 2 STAGE COOL AND HEAT THERMOSTAT
COOLING I HEATING (ELECTRONIC THERMOSTAT)
SINGLE STAGE
THERMOSTAT.
TERMINALS UNIT TERMINAL
RH STRIP TB1
ADD- -------- -1 ...... Yi
JUMPER
...............
GG --------------- -- - -
24 VOLT
TRANSFORMER
'ELEC'r.ON C PROGRAMWV+BLE THERMOSTAT TYPICAL To CONTROL THE
ECONOKAiZER ON STAGE COOLING USE A2 STAGE COOL AND
HEAT THERN10SlAT
Unitary sales Idol v1.b.9.0 Information is subject to change without notice Check local codes Printed 10/28/2016
CONTACTOR
PIE D SUPPLIED
7a
DISCONNECT
, r-- _- :' '
I
SINGLE
II
= —
- - - - - - - -
-----------------Cr"-
- - - - C, -
-:_ _0- -
PHASE
POWER
GROUND
L _
SUPPLY
LUG
REFER ELECTRiCA1. DATA
TABLES TO SIZE THE DISCONNECT
SWITCH OVIRCURRENT
PROTECTION ANDA'IRING
CONTACTOR
FIELD -SUPPLIED
DISCONNECT
L -----------i-
I C} - r- THREE
L------------I--Q.^¢_ PHASE
GROUND L - - - - - - - - - - - - - - - J_ -a
LUG O__ > POWER
L SUPPLY
TYPICAL COOL/HEAT CONTROL WIRING
COOLING ONLY (24 VOLT THERMOSTAT) COOLING / HEATING (24 VOLT THERMOSTAT)
THERMOSTAT' UNIT TERMINAL THERMOSTAT'
TERMINALS STRIP T61 TERMINALS
UNIT TERMINAL
ISH STRIP STRIP TBI
24 VOLT ADD
C .. ...............
TRANSFORMER JUMPER .. ......... .... ..
U12' C ) - -------------- -- 24 VOLT
TRANSFORMER
ccn,) . . ................ _0
C, (AD - -------------- -110,
'24 VOLT THERMOSTAT TO CONTROL Ot,!
ECOMIZER ON SECOND 0-
S FACE COOLING USE A 2 STAGE COOLING THEIRNIOSTAT @ I
COOLING / HEATING (ELECTRONIC THERMOSTAT)
MULTI STAGE
THERMOSTA I
TERMINALS UNIT TERMINAL
ADD RC STRIP TE11 21 VOLT
JUMPER PH --------------------- R TRANSFORMER
Y1------------------- Y1
Y2 ---------- 2 ------- Y2
Vy 1 ......... ...... W 1
4 1V2 -'_-----'3 ------- N2
LEDI ---------------------
LF D 2 NOT
- ------------
SED
4
ADD Al
JUMPER A2
TO RENIO T E SENSOR
il IF USED
ELECTRON:C PROGrANIMABLE THERN4j°7AI TYF CAL
SECOND STAGE COOLING S NOT REOU PEP ON UN IS LES` E-,QNOf.I 'Ff,,
SECOND STAGE HEA1:NG S ONLY RLOU PEE) tUN I IN T, V, IH A Pv),;Q!,]A,,;E
ELECTR C HEATER -')R: STA,",E GA:z HEAT
• REMOVE JUMPER J2 FROMTERMINALS 4 AND C; ON JI PLUG CONNECTOR
PC ON UNITS WITH ECONOM..ZER TERN'INALS A] AND A2 PROVIDE A RELAY
OUTPUT TO CLOSE THE OUTDOOR ECONOMIZER DAMPERS WHEN THE
I
.HE RISIAI TO THE SEI -BACK POSI I ION
24 VOLT TH.ERNIOSTAT Tn CONTROL TrE ECONOMIZER ON THE SECOND
STAGE" COCILINC, OR TO eAVE AN ELECTRIC HEAT ACCESSORY VvtTH Tv,,O
5TAC;_:S0"-,7_Af jSF A 2 STAGE COOL AND HEAT THERMOSTAT
COOLING I HEATING (ELECTRONIC THERMOSTAT)
SINGLE STAGE
THERMOSTAT.
TERMINALS UNIT TERMINAL
RH STRIP TB1
ADD- -------- -1 ...... Yi
JUMPER
...............
GG --------------- -- - -
24 VOLT
TRANSFORMER
'ELEC'r.ON C PROGRAMWV+BLE THERMOSTAT TYPICAL To CONTROL THE
ECONOKAiZER ON STAGE COOLING USE A2 STAGE COOL AND
HEAT THERN10SlAT
Unitary sales Idol v1.b.9.0 Information is subject to change without notice Check local codes Printed 10/28/2016
Small Sunline (3-6 Ton Page: 12
YO R K Package) N543
Single Package R -410A Air Conditioner
Project Name: SOLA _ Unit Model #: ZE060H12B4C1EAA1A1
Quantity: 1 System: ZE060H12B4C1EAA1A1
2"TYP � COMPRESSOR
DUCT SUPPORT AND CONDENSER
BACK RAILS / END OF UNIT
OF UNIT
\ SUPPLY''
AIR /— \\\ r/ t
14
RETURN'
AIR
19-112--
37-1/4"
9-112"37-114
DUCT SIZES:
Supply Air = 19" x 19"
Return Air = 19" x, 19"
Unitary Sales Tool 0.5.9.0
��\•;�\X� '19-112„
/rte 4-112"�
FRONT
OF UNIT
- Supply and Return Air (including duct support rails)
Shown are typical for bottom duct applications.
For location of horizontal duct applications
(on back of units, refer to Unit Dimensions details.
1RC0414 Rent Curb Dimensions
Information is sublecl to change without notice. Check locel codes.
Printed 10/28/2016
Date
10/28/2016
Project Name
SOLA
Project Number
NN10281606
Client / Purchaser
PRECISE-LAMAR
Guide Specification Summary Page
Product Series Models and Unit Tags
Direct Fit (3-12.5 Ton Package) L526 ZXG08D4B3AA2B111A2 5 WKS -FACTORY BLD
Small Sunline (3-6 Ton Package) N543 ZE060H12B4C1EAA1A1
Unitary Sales Tool v1.5, 9.0 Information is subject to change without notice Check local codes Printed 10/28/2016
-----�-�—�------------- �-----Guide Specification for
--
Ibb do
MYORK
Direct Fit
DIVISION 23 — HEATING, VENTILATING, AND AIR-CONDITIONING(HVAC)�
!3 00 00 HEATING VENTILATING, AND AIR-CONDITIONING(HVAC)
23 06 00 Schedules for HVAC
23 06 80 Schedules for Decentralized HVAC Equipment
23 06 80. 13 Decentralized Unitary HVAC Equipment Schedule
23 06 80. 13.A Rooftop unit schedule
23 07 00 HVAC Insulation
23 07 16 HVAC Equipment Insulation
Page: 14
23 07 16. 13 Decentralized, Rooftop Units
23 07 16. 13.A Evaporator fan compartment
1. Interior cabinet surfaces shall be insulated with a minimum 1/2- in. thick, minimum 1 1/2 Ib density, flexible fiberglass
insulation bonded with a phenolic binder, neoprene coated on the air side.
2. Insulation and adhesive shall meet NFPA 90A requirements for flame spread and smoke generation.
23 07 16. 13.13 Gas heat compartment
1. Aluminum foil -faced fiberglass insulation shall be used.
2. Insulation and adhesive shall meet NFPA 90A requirements for flame spread and smoke generation.
23 09 00 Instrumentation and Control for HVAC
23 09 13. 23 Sensors and Transmitters
23 09 13. 23.A Thermostats
1. Thermostat must:
a. energize "G when calling for fan only or continuous fan.
b. have capability to energize 2 different stages of cooling.. and 2 different stages of heating.
c. include capability for occupancy scheduling.
23 09 23 Direct -digital Control system for HVAC
23 09 23, 13 Decentralized, Rooftop Units
23 09 23. 13.A Simplicity SE (Unit based microprocessor control)
1. Shall be ASHRAE 62-2001 compliant.
2. Shall include an integrated economizer controller to support an economizer with 4 to 20 mA actuator input.
3. Controller shall accept the following inputs: space temperature, setpoint adjustment, outdoor air temperature, indoor air
quality, outdoor air quality, indoor relative humidity, compressor lockout, fire shutdown, enthalpy, fan status, remote time
clock/door switch.
4. Shall accept a CO2 sensor in the conditioned space, and be Demand Control Ventilation ready.
5. Unit shall provide surge protection for the controller through a circuit breaker.
6. Shall have an LED display independently showing the status of activity on the communication bus, and processor
operation.
7. Software upgrades will be accomplished by local download. Software upgrades through chip replacements are not
allowed.
Guide Specification for
M'Q�-J=YORK Direct Fit
Page: 15
A. Unit shall be complete with self-contained low -voltage control circuit protected by a resettable circuit breaker on the 24 -volt
transformer side.
B. Unit shall incorporate a lockout circuit which provides reset capability at the space thermostat or base unit should any of the
following standard safety devices trip and shut off compressor:
C. Loss-of-charge/Low-pressureswitch.
D. High-pressure switch.
E. Freeze -protection thermostat, evaporator coil. If any of the above safety devices trip, an LED (light -emitting diode) indicator
shall flash a diagnostic code that indicates which safety switch has tripped.
F. Unit shall incorporate "AUTO RESET' compressor over temperature, over current protection.
G. Unit shall operate with conventional thermostat designs and have a low voltage terminal strip for easy hook-up.
H. Unit control board shall have on -board diagnostics and fault code display.
I. Standard controls shall include anti -short cycle and low voltage protection, and permit cooling operation down to 0 °F.
J. Control board shall monitor each refrigerant safety switch independently.
K. Control board shall retain last 5 fault codes in non-volatile memory, which will not be lost in the event of a power loss.
23 09 23. 13.13 RTU Open -multi -protocol, direct digital controller
1. Shall be ASHRAE 62-2001 compliant.
2. Shall include built-in protocol for BACNET , Modbus , and Johnson N2.
3. Shall allow access of up to 62 network variables (SNVT). Shall be compatible with all open controllers
4. Baud rate Controller shall be selectable using a dipswitch.
5. Shall have an LED display independently showing the status of serial communication, running, errors, power, all digital
outputs, and all analog inputs.
6. Shall accept the following inputs: space temperature, setpoint adjustment, outdoor air temperature, indoor air quality,
outdoor air quality, compressor lock- out, fire shutdown, enthalpy switch, and fan status/filter status/ humidity/ remote
occupancy.
7. Software upgrades will be accomplished by either local or remote download. No software upgrades through chip
replacements are allowed.
23 09 33 Electric and Electronic Control System for HVAC
23 09 33. 13 Decentralized, Rooftop Units
23 09 33. 13.A General
1. Shall be complete with self- contained low- voltage control circuit protected by a resettable circuit breaker on the 24-v
transformer side. Transformer shall have 75VA capability.
2. Shall utilize color -coded wiring.
3. Shall include a central control terminal board to conveniently and safely provide connection points for vital control
functions such as: smoke detectors, phase monitor, gas controller, economizer, thermostat, DDC control options, and
low and high pressure switches.
4. The heat exchanger shall be controlled by an integrated gas controller (IGC) microprocessor. See heat exchanger
section of this specification.
23 09 33. 23.13 Safeties
1. Compressor over -temperature, over -current. High internal pressure differential.
2. Low-pressure switch.
a. Units with 2 compressors shall have different sized connectors for the circuit 1 and circuit 2 low and high pressure
switches. They shall physically prevent the cross- wiring of the safety switches between circuits 1 and 2.
b. Low pressure switch shall use different color wire than the high pressure switch. The purpose is to assist the
installer and service technician to correctly wire and or troubleshoot the rooftop unit.
3. High pressure switch.
a. Units with 2 compressors shall have different sized connectors for the circuit 1 and circuit 2 low and high pressure
switches. They shall physically prevent the cross -wiring of the safety switches between circuits 1 and 2.
MYORK
Guide Specification for
Direct Fit
rel
Page: 16
High pressure switch shall use different color wire than the low pressure switch. The purpose is to assist the
installer and service technician to correctly wire and or troubleshoot the rooftop unit.
4. Automatic reset,/motor thermal overload protector.
5. Heating section shall be provided with the following minimum protections:
a. High-temperature limit switches.
b. Induced draft motor speed sensor.
c. Flame rollout switch.
d. Flame proving controls
23 09 93 Sequence of Operations for HVAC Controls
23 09 93. 13 Decentralized, Rooftop Units
23 09 93. 13 INSERT SEQUENCE OF OPERATION
23 40 13 Panel Air Filters
23 40 13. 13 Decentralized, Rooftop Units
23 40 13. 13.A Standard filter section
1. Shall consist of factory -installed, low velocity, disposable 2" thick fiberglass filters of commercially available sizes.
2. Units can accept 2" or 4" filters and have a field convertible toolless
3. Filters shall be accessible through an access panel with toolless removal as described in the unit cabinet section of this
specification (23 81 19.13.1-1).
23 81 19 Self -Contained Air Conditioners
23 81 19. 13 Small -Capacity Self -Contained Air Conditioners
23 81 19. 13.A General
1. Outdoor, rooftop mounted, electrically controlled, heating and cooling unit utilizing a fully hermetic scroll compressor(s)
for cooling dutyand gas combustion for heating duty.
2. Factory assembled, single -piece heating and cooling rooftop unit. Contained within the unit enclosure shall be all
factory wiring, piping, controls, and special features required prior to field start-up.
3. Unit shall use environmentally sound, R-41 OA refrigerant.
4. Unit shall be installed in accordance with the manufacturer's instructions.
5. Unit must be selected and installed in compliance with local, state, and federal codes.
23 81 19. 13.13 Quality Assurance
1. Unit meets ASHRAE 90.1 minimum efficiency requirements.
3. Unit shall be rated in accordance with AHRI Standards 210/2.40 and 340/360.
4. Unit shall be designed to conform to ASHRAE 15, 2001.
5. Unit shall be UL -tested and certified in accordance with ANSI Z21.47 Standards and UL -listed and certified under
Canadian standards as a total package for safety requirements.
6. Insulation and adhesive shall meet NFPA 90A requirements for flame spread and smoke generation.
7. Unit casing shall be capable of withstanding 1000 -hour salt spray exposure per ASTM B117 (scribed specimen).
8. Unit shall be designed in accordance with ISO 9001, and shall be manufactured in a facility registered by; ISO 9001.
9. Roof curb shall be designed to conform to NRCA Standards.
10. Unit shall be subjected to a completely automated run test on the assembly line. The data for each unit; will be stored
at the factory, and must be available upon request.
11. Unit shall be designed in accordance with UL Standard 1995, including tested to withstand rain.
12. Unit shake tested to assurance level 1, ASTM D4169 to ensure shipping reliability.
13. High Efficient Motors listed shall meet section 313 of the Energy Independence and Security Act of 2007; (EISA 2007).
i�YORK
23 81
23 81
23 81
3.
4.
5.
6.
23 81
Guide Specification for
Direct Fit
Pager 17
19. 133 Delivery, Storage, and Handling
Unit shall be stored and handled per manufacturer's recommendations.
19. 13.E Project Conditions
As specified in the contract.
19. 13.F Operating Characteristics
Unit shall be capable of starting and running at 125°F (52°C)ambient outdoor temperature, meeting maximum load
criteria of AHRI Standard 2.10/240 or 340/360 at ± 10% voltage.
Compressor with standard controls shall be capable of operation down to 0°F (2°C), ambient outdoor temperatures. See
below for head pressure control package or winter start kit.
Unit shall discharge supply air vertically or horizontally as shown on contract drawings.
Unit shall be factory configured for vertical supply & return configurations.
Unit shall be field convertible from vertical to horizontal airflow on all models.
Unit shall be capable of mixed operation: vertical supply with horizontal return or horizontal supply with vertical return.
19. 13.G Electrical Requirements
1. Main power supply voltage, phase, and frequency must match those required by the manufacturer.
23 81 19. 13.H Unit Cabinet
1. Unit cabinet shall be constructed of galvanized steel with exterior surfaces coated with a non -chalking, powder
paint finish, certified at 1000 hour salt spray test per ASTM -6117 standards.
2. Evaporator fan compartment interior cabinet insulation shall conform to AHRI Standards 210/240 or 340/360 minimum
exterior sweat criteria. Interior surfaces shall be insulated with a minimum 1/2- in. thick, 1 Ib density, flexible fiberglass
insulation, neoprene coated on the air side. Aluminum foil- faced fiberglass insulation shall be used in the gas heat
compartment. Fan shall be a belt drive assembly and include an adjustable pitch motor pulley. Fan wheel shall be
double inlet type with forward curve blades, dynamically balanced to operate smoothly throughout the entire range of
operation. Airflow design shall be constant volume. Bearings shall be sealed and permanently lubricated for longer life
and no maintenance. Entire blower assembly and motor shall be slide out design.
3. Condenser Fan Assembly: The outdoor fans shall be of the direct drive type, discharge air vertically, have aluminum
blades riveted to corrosion resistant steel spider brackets and shall be dynamically balanced for smooth operation. The
outdoor fan motors shall have permanently lubricated bearings internally protected against overload conditions and
staged independently. A cleaning window shall be provided on two sides of the units for coil cleaning.
4. Base of unit shall have a minimum of four locations for thru-the-base gas and electrical connections (factory installed or
field installed), standard.
5. Base Rail
a. Unit shall have base rails on a minimum of 4 sides.
b. Holes shall be provided in the base rails for rigging shackles to facilitate maneuvering and overhead rigging.
c. Holes shall be provided in the base rail for moving the rooftop by fork truck..
d. Base rail shall be a minimum of 16 gauge thickness.
6. Condensate pan and connections
a. Shall be an internally sloped condensate drain pan made of a non -corrosive material.
b. Shall comply with ASHRAE Standard 62.
c. Shall use a 3/4" - 14 NPT drain connection, possible either through the bottom or side of the drain pan. Connection
shall be made per manufacturer's recommendations.
7. Top panel
a. Shall be a single piece top panel.
8. Gas Connections
a. All gas piping connecting to unit gas valve shall enter the unit cabinet at a single location on side of unit
b. Thru-the-base capability
(1.) Standard unit shall have a thru-the-base gas- line location using a raised, embossed portion of the unit
basepan.
(2.) Optional, factory- approved, water- tight connection method must be used for thru-the-base gas
connections.
(3.) No basepan penetration, other than those authorized by the manufacturer, is permitted.
Kilj�YORK
9. Electrical Connections
Guide Specification for
Direct Fit
Page: 18
a. All unit power wiring shall enter unit cabinet at a single, factory -prepared, knockout location.
b. Thru-the-base capability.
(1.) Standard unit shall have a thru-the-base electrical location(s) using a raised, embossed portion of the unit
basepan.
(2.) Optional, factory- approved, water -tight connection method must be used for thru-the-base electrical
connections.
(3.) No basepan penetration, other than those authorized by the manufacturer, is permitted.
10. Component access panels (standard)
a. Cabinet panels shall be easily removable for servicing.
b. Unit shall have one factory installed, toolless, removable, filter access panel.
c. Panels covering control box, indoor fan, indoor fan motor, gas components(where applicable), and compressors
shall have a molded composite handles.
d. Handles shall be UV modified, composite. They shall be permanently attached, and recessed into the panel.
e. Screws on the vertical portion of all removable access panel shall engage into heat resistant, molded composite
collars.
f. Collars shall be removable and easily replaceable using manufacturer recommended parts.
23 81 19. 13.1 Gas Heat
1. General
a. Heat exchanger shall be an induced draft design. Positive pressure heat exchanger designs shall not be allowed.
b. Shall incorporate a direct- spark ignition system and redundant main gas valve.
c. Gas supply pressure at the inlet to the rooftop unit gas valve must match that required by the manufacturer.
2. The heat exchanger shall be controlled by an integrated gas controller (IGC) microprocessor.
a. IGC board shall notify users of fault using an LED (light-ernitting diode).
b. The LED shall be visible without removing the control box access panel.
c. IGC board shall contain algorithms that modify evaporator -fan operation to prevent future cycling on high
temperature limit switch.
d. Unit shall be equipped with anti -cycle protection with one short cycle on unit flame rollout switch or 4 continuous
short cycles on the high temperature limit switch. Fault indication shall be made using an LED.
3. Standard Heat Exchanger construction
a. Heat exchanger shall be of the tubular -section type constructed of a minimum of 20 -gauge steel coated with a
nominal 1.2 mil aluminum -silicone alloy for corrosion resistance.
b. Burners shall be of the in -shot type constructed of aluminum -coated steel.
c. Burners shall incorporate orifices for rated heat output up to 2000 ft (610m) elevation. Additional accessory kits
may be required for applications above 2000 ft (610m) elevation, depending on local gas supply conditions.
d. Each heat exchanger tube shall contain multiple dimples for increased heating effectiveness.
6. Induced draft combustion motor and blower
a. Shall be a direct -drive, single inlet, forward -curved centrifugal type.
b. Shall be made from steel with a corrosion -resistant finish.
c. Shall have permanently lubricated sealed bearings.
d. Shall have inherent thermal overload protection.
e. Shall have an automatic reset feature.
23 81 19. 13.J Coils
1. Standard Aluminum Fin/Copper Tube Coils
a. Standard evaporator and condenser coils shall have aluminum lanced plate fins mechanically bonded to seamless
internally grooved copper tubes with all joints brazed.
b. Evaporator coils shall be leak tested to 150 prig, pressure tested to 450 psig, and qualified to UL. 1995 burst test at
1775 psig.
c. Condenser coils shall be leak tested to 150 psig, pressure tested to 650 psig, and qualified to UL 1995 burst test at
1980 psig.
Guide Specification forMYORK' Page: 19
Direct Fit
23 81 19. 13.K Refrigerant Components
1. Refrigerant circuit shall include the following control, safety, and maintenance features
a. 'Thermostatic Expansion Valve (TXV) shall help provide optimum performance across the entire operating range.
Shall contain removable power element to allow change out of power element and bulb without removing the valve
body.(Orifice on 3-5 Ton Units)
b. Refrigerant filter drier - Solid core design.
c. Service gauge connections on suction and discharge lines.
d. Pressure gauge access through a specially designed access port in the top panel of the unit.
2. There shall be gauge line access port in the skin of the rooftop, covered by a black, removable plug.
a. The plug shall be easy to remove and replace.
b. When the plug is removed, the gauge access port shall enable maintenance personnel to route their pressure
gauge lines.
c. This gauge access port shall facilitate correct and accurate condenser pressure readings by enabling the reading
with the compressor access panel on.
d. The plug shall be made of a leak proof, UV- resistant, composite material.
3. Compressors
a. Unit shall use fully hermetic, scroll compressor for each independent refrigeration circuit.
b. Compressor motors shall be cooled by refrigerant gas passing through motor windings.
c. Compressors shall be internally protected from high discharge temperature conditions.
d. Compressors shall be protected from an over -temperature and over -amperage conditions by an internal, motor
overload device.
e. Compressor shall be factory mounted on rubber grommets.
f. Compressor motors shall have internal line break thermal, current overload and high pressure differential
protection.
g. Crankcase heaters shall not be required for normal operating range, unless provided by the factory.
23 81 19. 131 Filter Section
1. Filters access is specified in the unit cabinet section of this specification.
2. Shall consist of factory -installed, low velocity, throw -away 2" thick fiberglass filters.
3. Units can accept 2" or 4" filters and have a field convertible toolless
23 81 19. 13.M Evaporator Fan and Motor
1. Evaporator fan motor
a. Shall have permanently lubricated bearings.
b. Shall have inherent automatic -reset thermal overload protection or circuit breaker.
3. Belt -driven Evaporator Fan
a. Belt drive shall include an adjustable -pitch motor pulley.
b. Shall use sealed, permanently lubricated ball-bearing type.
c. Blower fan shall be double -inlet type with forward -curved blades.
d. Shall be constructed from steel with a corrosion resistant finish and dynamically balanced.
23 81 19. 13.N Condenser Fans and Motors
The outdoor fans shall be of the direct drive type, discharge air vertically, have aluminum blades riveted to corrosion resistant
steel spider brackets and shall be dynamically balanced for smooth operation. The outdoor fan motors shall have permanently
lubricated bearings internally protected against overload conditions and staged independently. A cleaning window shall be
provided on two sides of the units for coil cleaning.
1. Condenser fan motors
a. Shall be a totally enclosed motor.
b. Shall use permanently lubricated bearings.
c. Shall have inherent thermal overload protection with an automatic reset feature.
d. All models shall use a shaft -down design except shaft -up on ZX14 & ZY12 size with rain shield.
2. Condenser Fans
YORK
4910
2
3
Guide Specification for
Direct Fit
a. Shall be a direct -driven propeller type fan.
b. Shall have aluminum blades riveted to corrosion -resistant steel spiders and shall be dynamically balanced.
19. 13.0 Special Features Options and Accessories
IntelliSpeed-Staged Air Volume System (ZX12, ZX14, &ZY12)
a. Evaporator fan motor:
Page: 20
(1.) Shall have permanently lubricated bearings.
(2.) Shall have a maximum continuous bhp rating for continuous duty operation; no safety factors above that
rating.
(3.) Shall be Variable Frequency duty and 2 -speed control.
(4.) Shall contain motor shaft grounding ring to prevent electrical bearing fluting damage by safely diverting
harmful shaft voltages and bearing currents to ground.
Variable Frequency Drive (VFD). Only available on 2 -speed indoor fan motor option (IntelliSpeed)
INSERT MITSUBISHI DRIVE SPECIFICATIONS
Standard Integrated Economizers:
a. Integrated, gear -driven opposing modulating blade design type capable of simultaneous economizer and
compressor operation.
b. Independent modules for vertical or horizontal return configurations shall be available. Vertical return modules shall
be available as a factory installed option.
c. Damper blades shall be galvanized steel with composite gears. Plastic or composite blades on intake or return
shall not be acceptable.
d. Shall include all hardware and controls to provide free cooling with outdoor air when temperature and/or humidity
are below setpoints.
e. Shall be equipped with gear driven dampers for both the outdoor ventilation air and the return air for positive air
stream control.
f. Standard models shall be equipped with low- leakage dampers, not to exceed 2% leakage at 1 in. wg pres- sure
differential. Economizers will come with Actuator and module that is tied to Simplicity SE
(1.) Combined minimum and DCV maximum damper position potentiometers with compressor staging re-lay.
(2.) Functions with solid state analog enthalpy or dry bulb changeover control sensing.
(3.) Contain LED indicates for:when free cooling is availablewhen module is in DCV mode when exhaust fan
contact is closed
14. Return Air Enthalpy Sensor:
a. The return air enthalpy sensor shall be used in conjunction with an outdoor air enthalpy sensor to provide
differential enthalpy control.
11KW"`Y0RKL`
GENERAL
Guide Specification for
York Sunline
Units shall be manufactured by Johnson Controls Unitary
Products in an ISO 9001 certified facility. York Sunline
units are convertible single package units. Although the
units are primarily designed for curb mounting on a roof,
they can also be slab -mounted at ground level or set on
steel beams above a finished roof. Cooling only, cooling
with gas heat and cooling with electric heat models are
available with a wide variety of factory -mounted options
and field -installed accessories to make them suitable for
i almost every application. All units are self-contained and
assembled on full perimeter base rails with holes in the
four corners for overhead rigging. Every unit is
completely piped, wired, charged and tested at the
factory to simplify the field installation and to provide
years of dependable operation. All models (including
those with an economizer) are suitable for either bottom
or horizontal duct connections. Models with power
I exhaust are suitable for bottom duct connections only.
For bottom duct, remove the sheet metal panels from the
supply and return air openings through the base of the
unit. For horizontal duct, remove the supply and return
air panels on the rear of the unit.
All non -Scroll compressors include crankcase heaters and
all compressors have internal pressure relief. Every
refrigerant circuit includes a liquid line filter -drier, a
1 discharge line high pressure switch and a suction line with
a freezestat and low pressure/loss of charge switch. The
unit control circuit includes a 75 VA transformer, a 24 -volt
circuit breaker and a relay board with a compressor
lockout circuit, a terminal strip for thermostat wiring, plus
an additional set of pin connectors to simplify the interface
of additional field controls. All models are CSA listed. All
models include a 1 -year limited warranty on the complete
unit. Compressors and electric heater elements carry a 5 -
year warranty. Aluminized steel and Stainless steel tubular
heat exchangers carry a 10 -year warranty.
DESCRIPTION
Units shall be factory -assembled, single packaged,
Electric Cooling/Gas Heat, Electric Cooling/Optional
Electric Heat, Heat Pump/Optional Electric Heat are
designed for outdoor mounted installation.
The 3 ton, 4 ton and 5 ton units shall have minimum SEER
rating of 13.0 with heat pumps having a 7.7 H.S.P.F. The 6
Ton Cooling only or Cooling with Electric Heat shall have
11.2 EER, 6 Fon Cooling with Gas Heat shall have 11.0
EER. They shall have built-in field convertible duct
connections for down discharge supply/return or horizontal
discharge supply/return, and be available with factory
installed options or field installed accessories. The units
shall be factory wired, piped, charged with R -410A
refrigerant and factory tested prior to shipment. All unit
wiring shall be both numbered and color coded. All units
the cooling performance shall be rated in accordance with
Page:
DOE and AHRI test procedures. Units shall be CSA listec
classified to ANSI Z21.47, UL 1995/CSA No. 236
standards.
UNIT CABINET
Unit cabinet shall be constructed of galvanized steel, wO
exterior surfaces coated with a non -chalking, powdered
paint finish, certified at 1000 hours salt spray test per
ASTMB117 standards. Indoor blower section shall be
insulated with a minimum 1/2" thick insulation, coated on
the airside. Aluminum foil faced insulation shall be used i
the furnace compartment and be fastened with ridged
fasteners to prevent insulation from entering the air
stream. Cabinet panels shall be "large" size, easily
removable for servicing and maintenance. Full perimeter
base rails shall be provided to assure reliable transit of
equipment, overhead rigging and proper sealing on roof
curb applications. Disposable 1" filters shall be furnished
and be accessible through a removable access door,
sealed airtight. Units filter track shall be designed to
accommodate either 1" or 2" filters. Fan performance
measuring ports shall be provided on the outside of the
cabinet to allow accurate air measurements of evaporate,
fan performance without removing panels or creating air
by-pass of the coils. Condensate pan shall be internally
sloped and conform to ASHRAE 62-89 self -draining
standards. Condensate connection shall be a minimum e
3/4" I.D. female and be a ridged mount connection.
INDOOR (EVAPORATOR) FAN ASSEMBLY
The indoor fan shall be a factory installed direct -drive or
belt -drive assembly that includes an adjustable pitch mot
pulley. Job site selected (B.H.P.) brake horsepower shall
not exceed the motors nameplate horsepower rating, plu
the service factor. Units shall be designed not to operate
above service factor. Fan wheel shall be double -inlet typ(
with forward -curved blades, dynamically balanced to
operate smoothly throughout the entire range of operatic,
Airflow design shall be constant air volume. Bearings she
be sealed and permanently lubricated for longer life and
no maintenance
OUTDOOR (CONDENSER) FAN ASSEMBLY
The outdoor fan shall be of the direct -driven propeller typ
discharge air vertically, have aluminum blades riveted to
corrosion resistant steel spider bracket and shall be
dynamically balanced for smooth operation. The outdoor
fan motor shall be totally enclosed with permanently
lubricated bearings, internally protected against overload
conditions and staged independently.
I
Unitary Sales Fool v1.ty 9 0 s %"OjeGI to chinge mlhoul nw,( e Check local .;odes Printed 10128/2016
Guide Specification for Page: 22
6092"YORK York Sunline
REFRIGERANT COMPONENTS
f. Unit shall incorporate "AUTO RESET' compressor
Compressors:
over temperature, over current protection.
a. Shall be internally protected with internal high-
g. Unit shall operate with conventional thermostat
pressure relief and over temperature protection.
designs and have a low voltage terminal strip for
b. Shall have internal spring isolation and sound
easy hook-up.
muffling to minimize vibration and noise, and be
h. Unit control board shall have on-board diagnostics
externally isolated on a dedicated, independent
and fault code display.
mounting.
i. Standard controls shall include anti-short cycle and
Coils:
low voltage protection, and permit cooling operation
down to 0'F.
a. Evaporator coils shall have aluminum plate fins
j. Control board shall monitor each refrigerant safety
mechanically bonded to seamless internally
switch independently.
enhanced copper tubes with all joints brazed. Special
k. Control board shall retain last 5 fault codes in non
Phenolic coating shall be available as a factory
volatile memory which will not be lost in the event of a
option.
power loss.
b. Evaporator coils shall be of the direct expansion,
draw-thru design.
GAS HEATING SECTION
c. Condenser coils shall have aluminum plate fins
Shall be designed with induced draft combustion with
mechanically bonded to seamless internally
enhanced copper tubes with all joints brazed or
post purge logic, energy saving direct spark ignition, and
Micro-Channel aluminum tube, aluminum fins.
redundant main gas valve. Venter wheel shall be
constructed of stainless steel for corrosion resistance.
d. Condenser coils shall be of the direct expansion,
The heat exchanger shall be of the tubular type,
draw-thru design.
constructed of T1-40 aluminized steel for corrosion
resistance and allowing minimum mixed air entering
Refrigerant Circuit and Refrigerant Safety Components
temperature of 25°F. Burners shall be of the inshot type,
shall include:
constructed of aluminum coated steel and contain air
mixture adjustments. All gas piping shall enter the unit
a. Independent fixed-orifice or thermally operated
cabinet at a single location through either the side or
expansion devices.
curb without any field modifications. Integrated control
b. Filter drier/strainer to eliminate any moisture or
boards shall provide timed control of evaporator fan
foreign matter.
functioning and burner ignition. Heating section shall be
c. Accessible service gage connections on both suction
provided with the following minimum protection.
and liquid lines to charge, evacuate, and measure
a, Primary and auxiliary high-temperature limit switches.
refrigerant pressure during any necessary servicing
or troubleshooting, without losing charge.
b. Induced draft motor speed sensor.
d. The refrigeration system shall provide at least 1 YF of
c. Flame roll out switch.
sub-cooling at design conditions.
d. Flame proving controls.
Unit Controls:
e. If any of the above safety devices trip, a LED (light-
emitting diode) indicator shall flash a diagnostic code
a. Unit shall be complete with self-contained low-voltage
that indicates which safety switch has tripped.
control circuit protected by a resettable circuit breaker
on the 24-volt transformer side.
NOTE: All 2 Stage Gas Heat, 60% Capacity 1st Stage,
b. Unit shall incorporate a lockout circuit which provides
40% Capacity 2nd Stage.
reset capability at the space thermostat or base unit,
UNIT OPERATING CHARACTERISTICS
should any of the following standard safety devices
trip and shut off compressor.
Unit shall be capable of starting and running at 125°F
c. Loss-of-charge/Low-pressure switch.
outdoor temperature, exceeding maximum load criteria
of AHRI Standard 210/240. The compressor, with
d. High-pressure switch.
standard controls, shall be capable of operation down to
e. Freeze-protection thermostat, evaporator coil.
0°F outdoor temperature. Unit shall be provided with fan
time delay to prevent cold air delivery before heat
exchanger warms up (Gas heat only).
Unitary Sales Tool v1..5.9.0 Information is subject to change wlthoul notice. Check local codes Printed 10/28/2016
- MYORK Guia
ELECTRICAL REQUIREMENTS
All unit power wiring shall enter unit cabinet at a si
factory provided location and be capable of side o
bottom entry, to minimize roof penetrations and av
unit field modifications. Separate side and bottom
openings shall be provided for the control wiring.
STANDARD LIMITED WARRANTIES
• Compressor 5 Years
• Heat Exchanger 10 Years
• Electric Heat Element 5 Years
• Other Parts 1 Year
OPTIONAL OUTDOOR AIR
Economizer — Outdoor and return air damper
are interlocked and positioned by a fully-modl,
spring return damper actuator. The maximum
rate for the outdoor air intake dampers shall n
exceed 2% when dampers are fully closed an
operating against a pressure differential of 0.1
A unit -mounted potentiometer shall be provid(
adjust the outdoor and return air damper asse
take in CFM of outdoor air to meet the miniml,
ventilation requirement of the conditioned spa
during normal operation. During economizer
operation, a mixed -air temperature control shi
modulate the outdoor and return air damper
assembly to prevent the supply air temperatui
dropping below 55°F. The outdoor intake opei
shall be covered with a rain hood that matche
exterior of the unit. Water eliminator/filters shz
provided. Simultaneous economizer/compres
operation is also possible. Dampers shall fully
on power loss.
ADDITIONAL FACTORY INSTALLED OPTIONS
• BAS Controls
FIELD INSTALLED OPTIONS
Roof Curb — 14" high, full perimeter curb witl-
nailer (shipped knocked -down).
Barometric Relief Damper — This damper at:
can be used to relieve internal building air pre
on units with an economizer without power e�
This accessory includes a rain hood, a bird sc
and a fully assembled damper. With bottom d
connections, the damper should be mounted
opening in the return air panel. With horizont�
ductwork, the accessory should be mounted c
return air duct.
Unitary Sales Tool 0.5.9.0 Information is subject to change without notice. Check local codes, Printed 10/28/2016
2012 Washington State Energy Code Compliance Forms for Commercial, Group R1, and > 3 story R2 and R3
h`ll co-w-Ul Sz
ULL 6 U zu1b
PERMIT CENTER
Mechanical Summary MECH-SUM
2012 Seattle Energy Code Compliance Forms for Commercial Buildiaas inch,din R2 li R3 over 3 stories and all R1 Revised Sept 2015
Project Info
Project Address SOLA SALON STUDIOS
Date 12/15/2016
351 STRANDER BLVD For Building Dept. Use
TUKWILA, WA 98188
Applicant Name PRECISE HEATING AND COOLING
Applicant Address P.0, BOX 1455, MONROE, WA, 98272
Applicant Phone 206-510-4250
New Building L i Building Addition Fenant Improvement system Retrofit No System Changes
Project Description
Briefly describe mechanical systems in
4 SUPPLY AND DUCT SYSTEMS FOR EACH OF 4 ROOF -FOP AHUS 2 EXHAUST SYSTEMS TO SERVE 2
the text box provided
NEW ROOFTOP FANS.
-] Total Bldg Performance
notal Bldg Performance compliance
Includes all mandatory provisions per
C401 2 Option 2 ME Cl I -SUM,
MECH-CIIK, and 0407 Energy
Analysis Summary forms required
Mechanical Systems Summary
Air
Compliance
Heating
Fan Flow
Economizer
Ventilation
Equip ID
Type of System (Note 1)
Sl Served
Path
and Cooling
Controls
(Note 2)
(Note 3)
Energy Recovery
AHI -11
UNITARY ROOFTOP AHU
WEST SIDE STUDIOS
Complex multi
zone system
Heating and
cooling
Constant
volume (CV)
Yes
Not
Applicable
Not Required
AHU-2
UNITARY ROOFTOP AHU
MIDDLE WEST STUDIOS
Complex multi
zone system
Heating and
cooling
Constant
volume (CV)
Yes
Not
Applicable
Not Required
AHU-3
UNITARY ROOFTOP AHIJ
MIDDLE EAST STUDIOS
Complex multi
zone system
Heating and
cooling
g
Constant
volume (CV)
Yes
Not
Applicable
Not Required
AHU-4
UNITARY ROOFTOP AHU
EAST SIDE STUDIOS
Complex multi
zone system
Heating and
cooling
Constant
volume (CV)
Yes
Not
Applicable
Not Required
EAST SIDE/CENTRAL
Simple single
No heating or
Constant
No cooling,
Minimum per
Not Required
EF -1
ROOFTOP EXHAUST FAN
STUDIOS
zone system
cooling
volume (CV)
NA
IMC
Simple single
No heating or
Constant
No cooling,
Minimum per
Not Required
EF -1
ROOFTOP EXHAUST FAN
WEST SIDE STUDIOS
zone system
cooling
volume (CV)
NA
IMC
1
r-1 A MF -M P-
-61
WNW V L_
A.
-
Note Provide basic description of system type for example unitary rooftop air handier built-up central air handler sing) packaged, split system or packaged
-air furnace electric resistance heater, 4 -pipe fan coil. VRF ystem, energy recovery air handier.
terminal air conditioner or heat pump, unit heater. warm
of TL
-scarce heat pump, etc. qity *%-"IR
exception make-up air system ground or water e.otton taken from drop down menu and complete MLCH- F CON um arycfefinitionsofeai;h,,
to select
Note 2 - if taking an exception air economizer,
exception are listed in MLCH-ECONO
Note 3 If ventilation "Not applicable" is selected provide explanation in Project Oescoption box above
[---
Ilydronic chilled water Water loop heat pump ] No hydropic systems
IIVAC Hydronic Systems I CORRECTION
I I Hyaronic heating Geothermal CORR_
F quipmentType (s) No service water systems
Hot water heating tank($) Instantaneous
Heat exchangE� from space heat boiler or
Service Water Heating Dedicated boiler
central hot waterlstLani
Systems RECEIVED
Distribution Type (s)
Circulation System J On -demand CITY OF TUKWILA
h`ll co-w-Ul Sz
ULL 6 U zu1b
PERMIT CENTER
7()97 lA/nchinntnn Ctntp f-nernv Cone (.mmr)lianre Forms for Commercial. Group R1, and > 3 story R2 and R3
L 1 Mechanical Plans ] MPCIi CiQ Dorm
Mechanical Schedules
Indicate location of equipment compliance information If provided on plans then MF_CH-EQ forms are not required,
however. include on plans all applicable compliance information listed in MF_CH-EQ tables.
n Load calculation summary ❑ MECH-LOAD-CALC Form
Provide design load calculations for all mechanical systems and equipment serving the building heating, cooling or
ventilating needs. If a load calculation summary is provided with the permit documents that includes all applicable
Design Load Calculations
compliance information then the Ml -"C[ I -LOAD -CAI C form is not required.
Equipment retrofit and repair projects where design loads in space(s) served have not changed from original design
conditions are not required to perform load calculations
nn,� nl...ka +..n Q++o Gnn—, rnrip r,�n,nlianre Fnrms for Commercial, Group R1, and > 3 story R2 and R3
2012 Seattle Energy Code Compliance Forms for Commercial Buildings including R2 & R3 over 3 stories and all R1 Revised Sept 2015
�] Protect includes HVAC air distribution systems that provide heating and/or cooling
If yes, provide a MECH-FANSYS -SUM form
I'an Power
❑ For one or more systems, the total fan motor nameplate hp of all fans in HVAC system exceeds Shp.
If yes. provide a seperate MECH-FANSYS form for each HVAC system exceeding the 5 horsepower threshold.
Refer to Section C403.2 10 and ML=CH-FANSYS-DOC for requirements and exceptions.
Commissioning Exception
Commissioning will be provided for all applicable systems
Summary
Commissioning Exceptions'
Describe means of eligibilty for
commissioning exception (capacity,
�_ Mechanical system(s)
etc) for all systems noted as taking
exception in Mechanical Systems
Summary table. Refer to Section
Service water heating
C408.2 and C408.4 for exceptions.
system(s)
For systems requiring commissioning. Figure C408.1 2 1 Commissioning Compliance Checklist shall be submitted to the
code official upon project completion.
Low Energy and Semi-fleated Spaces (Note 6 and 7)
Peak Space
Heating Cooling Conditioning
Space
Type
Area Served, Capacity, Btu/h Capacity, Btu/h Capacity, Compliance
Location in Plan(s) Space(s) Served square feet (Note 4) (Note 5) Btu/h-sf Check Notes
Note 4 - Provide total installed heating output capacity of systems serving Low Energy or Sena -I feated space(s) in btuh
Note 5 - Provide total installed cooling capacity of system serving Low Energy space(s) in Btu/h Not allowed for semi -heated spaces. Enter 0 if oo cooling.
Note 6 - Refer to Section C101.5.2 Low E=nergy Building. Intalled peak space conditioning capacity. heating or cooling, may not exceed 3 4 Btu/h-sf
Note 7 - Refer to Section C402 1.4 and Semi -Ideated Space definition in Chapter 2 1 otal heating output capacity may not exceed 8 btuh/sf. Only systems without
electric resistance heating and no cooling are eligible for the wall insulation exception under semi. heated
City of Tukwila
Allan Ekberg, Mayor
Department of Community Development Jack Pace, Director
December 12, 2016
LAMAR MOORE
PO BOX 1455
MONROE, WA 98272
RE: Correction Letter # 1
MECHANICAL Permit Application Number M16-0182
SOLA SALON STUDIOS - 351 STRANDER BLVD
Dear LAMAR MOORE,
This letter is to inform you of corrections that must be addressed before your development permit can be approved. All
correction requests from each department must be addressed at the same time and reflected on your drawings. I have
enclosed comments from the following departments:
BUILDING - DEPARTMENT: KC ELLIS at 206-431-3677 if you have questions regarding these comments.
• Provide:
1. structural support calculations for the rooftop units
2. complete and return the WSEC mechanical summary sheets.
Please address the comments above in an itemized format with applicable revised plans, specifications, and/or other
documentation. The City requires that two 2 sets of revised plan pages, specifications and/or other documentation be
resubmitted with the appropriate revision block.
In order to better expedite your resubmittal, a'Revision Submittal Sheet' must accompany every resubmittal. I have
enclosed one for your convenience. Corrections/revisions must be made in person and will not be accepted through the mail
or by a messenger service.
If you have any questions, I can be reached at 206-433-7165.
Sincerely,
tey
Permit Technician
File No. M16-0182
6300 Southcenter Boulevard Suite #100 • Tukwila Washington 98188 • Phone 206-431-3670 • Fax 206-431-3665
PERMIT COORD COPY.
PLAN REVIEW/ROUTING SLIP
PERMIT NUMBER: M16-0182 DATE: 12/30/16
PROJECT NAME: SOLA SALON STUDIOS
SITE ADDRESS: 351 STRANDER BLVD
Original Plan Submittal Revision # before Permit Issued
X Response to Correction Letter # 1 Revision # after Permit Issued
DEPARTMENTS:
kJ tM16 Tv
Building Division Fire Prevention ❑ Planning Division ❑
Public Works ❑ Structural ❑ Permit Coordinator
PRELIMINARY REVIEW: DATE: 01/03/17
Not Applicable ❑ Structural Review Required ❑
(no approval/review required)
REVIEWER'S INITIALS: DATE:
APPROVALS OR CORRECTIONS: DUE DATE:
Approved ❑ Approved with Conditions ❑
Corrections Required ❑ Denied ❑
(corrections entered in Reviews) (ie: Zoning Issues)
Notation:
REVIEWER'S INITIALS: DATE:
Permit Center Use Only
CORRECTION LETTER MAILED:
Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials:
01/31/17
]2/18/2013
PERMIT COORD COPY
PLAN REVIEW/ROUTING SLIP
PERMIT NUMBER: M16-0182 DATE: 12/05/16
PROJECT NAME: SOLA SALON STUDIOS
SITE ADDRESS: ' 351 STRANDER BLVD
X Original Plan Submittal Revision # before Permit Issued
Response to Correction Letter # Revision # after Permit Issued
DEPARTMENTS:
wl� W KWU
Building Division Fire Prevention Planning Division ❑
Public Works ❑ Structural ❑ Permit Coordinator
PRELIMINARY REVIEW: DATE: 12/06/16
Not Applicable ❑ Structural Review Required ❑
(no approval/review required)
REVIEWER'S INITIALS: DATE:
APPROVALS OR CORRECTIONS:
Approved ❑
Corrections Required ❑
(corrections entered in Reviews)
Notation:
REVIEWER'S INITIALS:
DUE DATE: 01/03/17
Approved with Conditions ❑
Denied ❑
(ie: Zoning Issues)
DATE:
Permit Center Use Only
CORRECTION LETTER MAILED: owh
Departments issued corrections: Bldg Fire ❑ Ping ❑ PW ❑ Staff Initials:
12/18/2013
City of Tukwila
Department of Community Development
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206-431-3670
Web site: http://www.Tukwi]aWA.gov
REVISION
SUBMITTAL
Revision submittals must be submitted in person at the Permit Center.
Revisions will not be accepted through the mail, fax, etc.
Date: 1ZI Plan Check/Permit Number: M16-0.182
❑ Response to Incomplete Letter #
®, Response to Correction Letter # 1
❑ Revision # after Permit is Issued
❑ Revision requested by a City Building Inspector or Plans Examiner
❑ Deferred Submittal #
Project Name: SOLA SALON STUDIOS
Project Address: 351 STRANDER
Contact Person: 1.(n-tY a r- M 0-0 re
Summary of Revision:
L v �-L'u b F'i) K 1E c4-" U- kL fu
Sheet Number(s):
"Cloud" or highlight all areas of revision
Received at the City of Tukwila Permit Cei
Phone Number: IZo 6 J n 6– l 2-5-o
Steu-( ru ( k4L,
IN—Entered in TRAKiT on
W:\Permit Cemer\Applications-Handouts\Templaies\Porms\Word DocumentARevision Submittal Porm.doc
Revised: August 2015
PRECISE HEATING & COOLING LLC
Home Espafiol Contact
Safety & Health Claims & Insurance
OnWashington State Department of
Labor & Industries
PRECISE HEATING & COOLING LLC
Owner or tradesperson
PO BOX 1455
Wesco Insurance Co
MONROE, WA 98272
Principals
206-861-2525
MOORE, LAMAR RALPH, PARTNER/MEMBER
SNOHOMISH County
STRINGER, MICHAEL
Effective date
LEE, PARTNER/MEMBER
04/20/2014
(End: 04/24/2015)
Expiration date
Doing business as
PRECISE HEATING & COOLING LLC
WA UBI No. Business type
603 122 887 Limited Liability Company
Governing persons
LAMAR
MOORE
MICHAEL L STRINGER;
License
Page 1 of 2
Search L&I �— —
A-'LIndex Help MyL&I
Workplace Rights Trades & Licensing
Verify the contractor's active registration / license / certification (depending on trade) and any past violations.
Construction Contractor Active.
..........................................................
Meets current requirements.
License specialties
Heating/Vent/Air-Conditioning and Refrig
(HVAC/R)
License no.
PRECIHC891 L9
Effective — expiration
0612912011— 06/29/2017
Bond
Wesco Insurance Co
$6,000.00
Bond account no.
46W BO43501
Received by L&I
Effective date
04/07/2014
04/20/2014
Expiration date
Until Canceled
Bond history
Insurance
.......................
Ohio Security Ins Co $1,000,000.00
Policy no.
BKS55371340
Received by L&I Effective date
12/02/2016 11/29/2016
Expiration date
1 112 912 01 7
Help us improve
https:Hsecure.Ini.wa.gov/verify/Detail.aspx?UBI=603122887&LIC=PRECIHC891L9&SAW= 1/9/2017
PRECISE HEATING & COOLING LLC
Insurance history
Savings
...................
No savings accounts during the previous 6 year period.
Lawsuits against the bond or savings
No lawsuits against the bond or savings accounts during the previous 6 year period.
L&I Tax debts
...............................
No L&I tax debts are recorded for this contractor license during the previous 6 year period, but some debts
may be recorded by other agencies.
License Violations
...........................................
Infraction no.
....................
EJACH00852Satisfied
....................
Issue date
RCW/WAC
08/06/2015
19.28.041 RCW
Violation city
Violation amount
MONROE
$500.00
Type of violation
ELECTRICAL CITATION
Description
Offering, bidding, advertising, or performing
electrical installations, alterations or
maintenance outside the scope of the firm's
specialty electrical contractors license.
(Installing low voltage conductors at a
commercial site)
Infraction no.
ECHAE00750Satisfied
....................
Issue date
RCWiWAC
02/01/2012
19.28.041 RCW
Violation city
Violation amount
MONROE
$500.00
Type of violation
ELECTRICAL CITATION
Description
Offering to perform, submitting a bid for,
advertising, installing or maintaining cables,
conductors or equipment that convey or
utilize electrical current without having a valid
electrical contractor license.
Workers' comp
Do you know if the business has employees? If so, verify the business is up-to-date on workers' comp premiums.
L&I Account ID
217,035-00
.........................
Account is current.
Doing business as
PRECISE HEATING & COOLING LLC
Estimated workers reported
Quarter 3 of Year 2016 "4 to 6 Workers"
L&I account representative
T4 I MELVINA RAMSDELL (360)902-4814 - Email: RAMM235@lni.wa.gov
Workplace safety and health
Check for any past safety and health violations found on jobsites this business was responsible for.
0 Washington State Dept. of Labor & Industries. Use of this site is subject to the laws of the state of Washington.
Page 2 of 2
Help us improve
https:Hsecure.Ini.wa.gov/verify/Detail.aspx?UBI=603122887&LIC=PRECIHC891L9&SAW= 1/9/2017
AIR HANDLER SCHEDULE
TAG
MAKE
MODEL
WEIGHT
ESP
CFM
OSA
ELECTRICAL
EER
ECONO
VOLTS
PHASE
M.C.A.
AHU-1
YORK
ZE060H 12B4C1 EAA1 Al
632
0.60
2000
ATTACH TO GRID
460
3
2000
11.80
YES
AHU-2
YORK
ZXG08D4B3AA2B111A2
791
0.60
3000
SHEETROCK
460
3
20.4
11.00
YES
AHU-3
YORK
ZXG08D4B3AA2B111 A2
791
0.60
3000
El
460
3
20.4
11.00
YES
AHU-4
YORK
ZXG08D4B3AA2B111 A2
791
0.60
3000
ROUND DUCT UP
460
3
20.4
11.00
YES
FAN SCHEDULE
TAG
MAKE AND MODEL
CFM
ESP
SONES
VOLTAGE
TYPE
WEIGHT
BDD
NOTES
EF -1
GREENHECK GB -141-7
1200
.81
13
460
ROOFTOP
72 LBS
YES
ATTACH TO GRID
EF -2
PRICE 80
2000
ATTACH TO GRID
EG -2
460
ROOFTOP
SHEETROCK
YES
PRICE SMCD
ZONE DAMPER SCHEDULE
TAG
MAKE AND MODEL
VOLTAGE
NOTES
ZD
WATTMASTER AZ2-200-ZV1
120
PROVIDE 120V FOR CONTROL POWER
BYPASS DAMPER SCHEDULE
TAG
MAKE AND MODEL
VOLTAGE
NOTES
ZD
WATTMASTER AZ2-301-RB-16
120
PROVIDE 120V FOR CONTROL POWER
VICINITY MAP
PARCEL NUMBER:
PERMIT NUMBER:
'di �;'s�ir^= iIJju�'t to err^�rS c'',Etd CJI is i
Approval of ccr►5 '70i; d CLItan's Lois mot au ho ; o
the violation or inv adopted code or ordinance. Fuc;::pi
of approved Fiaid Cop and conditions is acno°�;ic�'jr�d:
Ey. L
Data: 1_l AOI -,vii
BUILDING DIVISION
GRILL REGISTER AND DIFFUSER SCHEDULE
17'. !
trC?
TAG
REVISIONS
No charges
NOTES
shall b -i made to the scope
PRICE SPD
f w
rk without prior approval of
SD -2
Tukwila
Building Division.
NOTE:
l ie
I ions w*;Il rcquire a new plan submittal
and
ma
include additional plan review fees. I
PARCEL NUMBER:
PERMIT NUMBER:
'di �;'s�ir^= iIJju�'t to err^�rS c'',Etd CJI is i
Approval of ccr►5 '70i; d CLItan's Lois mot au ho ; o
the violation or inv adopted code or ordinance. Fuc;::pi
of approved Fiaid Cop and conditions is acno°�;ic�'jr�d:
Ey. L
Data: 1_l AOI -,vii
BUILDING DIVISION
GRILL REGISTER AND DIFFUSER SCHEDULE
17'. !
trC?
TAG
MAKE AND MODEL
SIZE
NOTES
SD -1
PRICE SPD
24" X 2411
ATTACH TO GRID_
SD -2
PRICE SMCD
0r' X 1011
10 11
0"
SHEETROCK
RG -1
PRICE 80
12" X 24"
ATTACH TO GRID
RG -2
PRICE 80
24" X 24"
ATTACH TO GRID
EG -1
PRICE 80
12" X 24"
ATTACH TO GRID
EG -2
PRICE SMCD
6" X 6"
SHEETROCK
EG -2
PRICE SMCD
10" X 1011
0"
SHEETROCK
HVAC ABBREVIATIONS
AFF
ABOVE FINISHED FLOOR
AHU
AIR HANDLING UNIT
BDD
BACKDRAFT DAMPER
BPD
BY-PASS DAMPER
BTUH
BRITISH THERMAL UNIT PER HOUR
CD
CEILING DIFFUSER
CFM
CUBIC FEET PER MINUTE
DB
DECIBAL
DH
DUCT HEATER
EA
EXHAUST AIR
EER
ENERGY EFFICIENCY RATIO
EG
EXHAUST GRILLE
ESP
EXTERNAL STATIC PRESSURE
EXH
EXHAUST
FCU
FAN COIL UNIT
FD
FIRE DAMPER, FLOOR DRAIN
FPM
FEET PER MINUTE
FSD
FIRE AND SMOKE DAMPER
GF
GAS FURNACE
GRD
GRILLE, REGISTER, DIFFUSER
OR:
0- tat
e Electrical
Ff.Plumbing
(Gas Piping
City of Tukwila
ILDING Dlyl 1
HVAC ABBREVIATIONS
HP HORSEPOWER, HEAT PUMP
HVAC HEATING, VENTILATING, AND AIR CONDITIONING
NTS NOT TO SCALE
OBD OPPOSED BLADE DAMPER
OD OUTSIDE DIMENSION OR DIAMETER
OSA OUTSIDE AIR
OU OUTDOOR UNIT
RG RETURN GRILLE
RPM REVOLUTIONS PER MINUTE
RA RETURN AIR
SA SUPPLY AIR
SG SUPPLY GRILLE
SP STATIC PRESSURE
TG TRANSFER GRILLE
VAV VARIABLE AIR VOLUME
VFD VARIABLE FREQUENCY DRIVE
VTR VENT TO ROOF
VVT VARIABLE VOLUME AND TEMPERATURE
ZD ZONE DAMPER
HVAC LEGEND
SYMBOL
DESCRIPTION
H
SUPPLY DIFFUSER
F-
RETURN GRILLE
+
DAMPER
O
THERMOSTAT
O
SENSOR
p(1)
EXHAUST FAN
Z
EXHAUST GRILLE
CONDENSING UNIT
0
INLINE EXHAUST FAN
ROOFTOP EXHAUST FAN
_j
SIDEWALL EXHAUST FAN
®
SUPPLY GRILLE
<
VAV FAN BOX
CEILING EXHAUST FAN
®
GAS METER
[�
WT DAMPER
FM
T -BAR SUPPLY DIFFUSER
E]
T -BAR RETURN GRILLE
f
1ff��Il
CEILING RADIATION
DAMPER ABOVE DIFFUSER
El
CEILING RADIATION
DAMPER ABOVE GRILLE
FDO
FIRE DAMPER
FSDIo
FIRE SMOKE DAMPER
Os
SMOKE DETECTOR
FLEXIBLE DUCT SARA
ROUND DUCT UP
ROUND DUCT DOWN
RTu
ROOFTOP UNIT
EF -1
EXHAUST FAN
SF -1
SUPPLY FAN
UH -1
UNIT HEATER
TRH -1
INFRARED HEATER
HP -1
HEAT PUMP
AC -1
AIR CONDITIONING UNIT
AHU-1
AIR HANDLING UNIT
HVAC NOTES
1. DUCT CONSTRUCTION, SEALING, AND INSULATION
TO MEET REQUIREMENTS OF SECTION
C403.2.9 OF THE 2015 WSEC. ALL DUCTWORK
SHOWN IS LOW PRESSURE UNLESS INDICATED
OTHERWISE.
2. SMOKE DETECTOR(S) INSTALLED IN MAIN RETURN
AS PER SECTION 606 OF THE 2015 IMC. HVAC
SMOKE DUCT DETECTORS SHALL SHUT DOWN
POWER TO THE UNIT UPON ACTIVATION AND, A
"SUPERVISOR " ZONE SHALL BE INITIATED AT THE
FIRE ALARM PANEL UPON SMOKE DUCT
DETECTOR ACTIVATION. IMC SECTION, 606.2.1
3. EQUIPMENT INSTALLATION INSTRUCTIONS TO BE
ON SITE FOR INSPECTIONS.
4. ALL HVAC EQUIPMENT TO BE LABELED TO THE
SPACE SERVED.
5. DUCTS TO BE SUPPORTED AT EACH DIRECTION
CHANGE - VERTICAL AT 12'-0" MAX., HORIZONTAL
AT 10'-0" MAX. WITH STRAP, OR 8'-0" MAX FROM
TRAPEZE SUPPORT.
6. SYSTEM CONTROLS TO MEET 2015 WSEC
SECTIONS 403.2.4.2/3
7. THE HVAC INSTALLATION SHALL BE COMPLETE
WHEN ALL SECTIONS OF 408 WSEC HAVE BEEN
SATISFIED. THIS SHALL INCLUDE AS -BUILT
DRAWINGS, SUBMITTALS, O&M MANUALS
SYSTEM BALANCE REPORT, AND COMMISSIONING
REPORT.
8. ALL ECONOMIZERS PROVIDED SHALL MEET 2015
WSEC SECTIONS C403.2.4.7, C403.3
9. ALL SUPPLY GRILLES TO HAVE VOLUME DAMPERS
FOR BALANCING OF SYSTEM UPON COMPLETION
10. ALL PIPING TO BE INSULATED ACCORDING TO
2015 IEC C402.10
11. FRESH AIR INTAKE AND RELIEF/EXHAUST, WILL BE
EQUIPPED WITH LOW LEAK, CLASS 1A MOTORIZED
DAMPERS THAT AUTOMATICALLY CLOSE DURING
UNOCCUPIED HOURS TO COMPLY WITH 2015 SEC
SECTION C402.4.5.2
xka.
3j
iiS
2
P.O. BOX 1 455
ONROE, WA
98272
206.510.4250
C)
00
H
>
F-
m
z
Z
p(1)
o
0
Q��
<
�-
_j
Y
<
T-
J
M0
�
M
APPROVAL STAMP
DRAWL BY:
KIRK OFFERDAHL
DRAWN FOR:
PRECISE HEATING & COOLING
DATE STARTED:
8/5/2016
DATE PLOTTED:
12/5/2016
SCALE:
REVISIONS:
/ / I DEC 0 . 201 1
DESCRIr11 t. lEVVED FOR
COVIfPM COMPLIANCE
APPROVED
JAN 06 2017
P2 -
SHEET -,I BUIL1 ING DIVISION
OF
M5
HVAC NOTES
O MANUAL BALANCING DAMPERS TO BE INSTALLED ON ALL SUPPLY DIFFU
O BYPASS DAMPER (BD -1) TO BE SIZED TO BYPASS DUCTWORK
HVAC - UPlp=2-`,LY AND RETURN SYSTEMS
SCALE: 1/411 = 11
APPROVAL STAMP
DRAWN BY:
KIRK OFFERDAHL
DRAViN FOR:
PRECISE HEATING & COOLING
DATE STARTED:
11/17/2016
DATE PLOTTED:
12/5/2016
SCALE: 1/4 to = 1'
REVISIONS:
NOW
klr
zl?•
APPROVED
w.
RECEIVED
CITY OF TUKWILA OF
DEC 05 2016 M5
PERMIT CENTER
HVAC NOTES
O BALANCING DAMPERS TO BE INSTALLED ON ALL EXHAUST GRILLES
Q INSTALL BALANCING DAMPERS IN DUCT DIRECTLY ABOVE AND DIFFUSER
0001111
<Ali A
�r.
1455
s�
�� ��r� �� MSN ROE, WA
Q, 98272
2 206.510.4250
O
— 2 2
XX
O. 0 . T T
0 0 -
,y
C O.:
rf,
c 2
0-1
4 � S
i
TQ T
<.
o:_ o.-. o: 0r co
a
° ° 0 0 9c ry m
0 0- LLQ v) Co
C) 00
O � �..
. : 000
T:
0 �0 � =baa j
1.
w
o
5�
0110 0 a— .�
y C co
01
w�w'� f iia �
„ -
11,11 -o:�
T T C�
L
glmmm0 o
I
I
o
0 _ =
at
�� CO
0
MK—u 0APPROVAL STAMP
9c
'uff
�x {0�
4
1�� �� O
.� /�
74, 7t—
IF, 0 � �a 0
0 — 0 0
o 0 ° 0
0
DRAWN BY:
T c O �� 1, KIRK OFFERDAHL
T T �T DRAWN FOR:
PRECISE HEATING & COOLING
C
DATE STARTED:
: A
11/17/2016
0 0
0 0 0:: o_ o 0_1 o o: o _ o, o: o:; 0 0,
DATE SLOTTED:
12/5/2016
c
T SCALE:
T
nT
T T ..,., 1 4 1
°101
=- REVISIONS:
0 ° 0 Q 0 O
5132
S
. �o _
r
O;_ O.� DES
cR •
a
INK D FOR
w PRO RE— L
WORAPPROVEDr � INCE
3: to Ing womilgilm
JAN 0 6 2017
a
SHEET: i 0 u i a
H v Au" Rmm%CP®EX"oF1'AUzr3T SYSI'EM BUIL IN VISION
4 IT
RECEIVED
1
SCALE: 1/4" = 1' CITY OF TUKWILA
DECU 0 5 2016
OF
PERMIT CENTER M 5
I�
�
IMC 2015 MINIMUM VENTILATION REQUIREMENTS
ROOM TYPE lAREAlQTY OCC. LOAD # PEOPLE OSA/PERSON OSA SUPPLY RETURN EXHAUST
BREAK ROOM 210 1 25 PER 1000 SF 6 20 118 250 - 250
MENS 52 1 - - - - - - 70
WOMENS 220 1 - - - - 250 - 210
CORRIDOR 1650 1 0.06 CFM/SF - - 99 400 300 -
ENTRY 60 1 0.06 CFM/SF - - 4 200 - -
SMALL STUDIO 110 28 25 PER 1000 SF 3 20 69 200 200 70
MEDIUM STUDIO 150 6 25 PER 1000 SF 4 20 93 250 250 100
LARGE STUDIO 210 4 25 PER 1000 SF 5 20 130 330 330 140
JANITORS CLOSET 10 1 1 1 - - - I - I - I - 1 100
ZONE DAMPER SCHEDULE
SYMBOL SIZE MODEL COMMENTS
ZD 1-1 8" AZ 2 -300 -RI -XX PROVIDE CONTROL POWER
ZD 1-2 8" AZ 2 -300 -RI -XX PROVIDE CONTROL POWER
ZD 1-3 8" AZ 2 -300 -RI -XX PROVIDE CONTROL POWER
ZD 1-4 10" AZ 2 -300 -RI -XX PROVIDE CONTROL POWER
ZD 1-5 8" AZ 2 -300 -RI -XX PROVIDE CONTROL POWER
BD 1 14" AZ 2 -300 -RI -XX PROVIDE CONTROL POWER
ZD 2-1 8" AZ 2 -300 -RI -XX PROVIDE CONTROL POWER
ZD 2-2 8" AZ 2 -300 -RI -XX PROVIDE CONTROL POWER
ZD 2-3 8" AZ 2 -300 -RI -XX PROVIDE CONTROL POWER
ZD 2-4 8" AZ 2 -300 -RI -XX PROVIDE CONTROL POWER
ZD 2-5 10" AZ 2 -300 -RI -XX PROVIDE CONTROL POWER
ZD 2-6 10" AZ 2 -300 -RI -XX PROVIDE CONTROL POWER
ZD 2-7 8" AZ 2 -300 -RI -XX PROVIDE CONTROL POWER
ZD 2-8 8" AZ 2 -300 -RI -XX PROVIDE CONTROL POWER
ZD 2-9 8" AZ 2 -300 -RI -XX PROVIDE CONTROL POWER
ZD 2-10 8" AZ 2 -300 -RI -XX PROVIDE CONTROL POWER
ZD 2-11 10" AZ 2 -300 -RI -XX PROVIDE CONTROL POWER
ZD 2-12 10" AZ 2 -300 -RI -XX PROVIDE CONTROL POWER
BD 2 16" AZ 2 -300 -RI -XX PROVIDE CONTROL POWER
ZD 3-1 8" AZ 2 -300 -RI -XX PROVIDE CONTROL POWER
ZD 3-2 8" AZ 2 -300 -RI -XX PROVIDE CONTROL POWER
ZD 3-3 8" AZ 2 -300 -RI -XX PROVIDE CONTROL POWER
ZD 3-4 10" AZ 2 -300 -RI -XX PROVIDE CONTROL POWER
ZD 3-5 10" AZ 2 -300 -RI -XX PROVIDE CONTROL POWER
ZD 3-6 10" AZ 2 -300 -RI -XX PROVIDE CONTROL POWER
ZD 3-7 8" AZ 2 -300 -RI -XX PROVIDE CONTROL POWER
ZD 3-8 8" AZ 2 -300 -RI -XX PROVIDE CONTROL POWER
ZD 3-9 8" AZ 2 -300 -RI -XX PROVIDE CONTROL POWER
ZD 3-10 10" AZ 2 -300 -RI -XX PROVIDE CONTROL POWER
BD 3 16" AZ 2 -300 -RI -XX PROVIDE CONTROL POWER
ZD 4-1 8" AZ 2 -300 -RI -XX PROVIDE CONTROL POWER
ZD 4-2 8" AZ 2 -300 -RI -XX PROVIDE CONTROL POWER
ZD 4-3 10" AZ 2 -300 -RI -XX PROVIDE CONTROL POWER
ZD 4-4 8" AZ 2 -300 -RI -XX PROVIDE CONTROL POWER
ZD 4-5 8" AZ 2 -300 -RI -XX PROVIDE CONTROL POWER
ZD 4-6 8" AZ 2 -300 -RI -XX PROVIDE CONTROL POWER
ZD 4-7 8" AZ 2 -300 -RI -XX PROVIDE CONTROL POWER
ZD 4-8 8" AZ 2 -300 -RI -XX PROVIDE CONTROL POWER
ZD 4-9 8" AZ 2 -300 -RI -XX PROVIDE CONTROL POWER
ZD 4-10 8" AZ 2 -300 -RI -XX PROVIDE CONTROL POWER
ZD 4-11 10" AZ 2 -300 -RI -XX PROVIDE CONTROL POWER
ZD 4-12 10" AZ 2 -300 -RI -XX PROVIDE CONTROL POWER
ZD 4-13 8" AZ 2 -300 -RI -XX PROVIDE CONTROL POWER
BD 4 16" AZ 2 -300 -RI -XX PROVIDE CONTROL POWER
AIR HANDLER SCHEDULE
TAG
MAKE
MODEL
WEIGHT
ESP
CFM
OSA
ELECTRICAL
EER
ECONO
VOLTS
PHASE
M.C.A.
AHU-1
YORK
ZE060H 12B4C1 EAA1 Al
632
0.60
2000
ATTACH TO GRID
460
3
2000
11.80
YES
AHU-2
YORK
ZXG08D4B3AA2B111A2
791
0.60
3000
SHEETROCK
460
3
20.4
11.00
YES
AHU-3
YORK
ZXG08D4B3AA2B111 A2
791
0.60
3000
El
460
3
20.4
11.00
YES
AHU-4
YORK
ZXG08D4B3AA2B111 A2
791
0.60
3000
ROUND DUCT UP
460
3
20.4
11.00
YES
FAN SCHEDULE
TAG
MAKE AND MODEL
CFM
ESP
SONES
VOLTAGE
TYPE
WEIGHT
BDD
NOTES
EF -1
GREENHECK GB -141-7
1200
.81
13
460
ROOFTOP
72 LBS
YES
ATTACH TO GRID
EF -2
PRICE 80
2000
ATTACH TO GRID
EG -2
460
ROOFTOP
SHEETROCK
YES
PRICE SMCD
ZONE DAMPER SCHEDULE
TAG
MAKE AND MODEL
VOLTAGE
NOTES
ZD
WATTMASTER AZ2-200-ZV1
120
PROVIDE 120V FOR CONTROL POWER
BYPASS DAMPER SCHEDULE
TAG
MAKE AND MODEL
VOLTAGE
NOTES
ZD
WATTMASTER AZ2-301-RB-16
120
PROVIDE 120V FOR CONTROL POWER
VICINITY MAP
PARCEL NUMBER:
PERMIT NUMBER:
'di �;'s�ir^= iIJju�'t to err^�rS c'',Etd CJI is i
Approval of ccr►5 '70i; d CLItan's Lois mot au ho ; o
the violation or inv adopted code or ordinance. Fuc;::pi
of approved Fiaid Cop and conditions is acno°�;ic�'jr�d:
Ey. L
Data: 1_l AOI -,vii
BUILDING DIVISION
GRILL REGISTER AND DIFFUSER SCHEDULE
17'. !
trC?
TAG
REVISIONS
No charges
NOTES
shall b -i made to the scope
PRICE SPD
f w
rk without prior approval of
SD -2
Tukwila
Building Division.
NOTE:
l ie
I ions w*;Il rcquire a new plan submittal
and
ma
include additional plan review fees. I
PARCEL NUMBER:
PERMIT NUMBER:
'di �;'s�ir^= iIJju�'t to err^�rS c'',Etd CJI is i
Approval of ccr►5 '70i; d CLItan's Lois mot au ho ; o
the violation or inv adopted code or ordinance. Fuc;::pi
of approved Fiaid Cop and conditions is acno°�;ic�'jr�d:
Ey. L
Data: 1_l AOI -,vii
BUILDING DIVISION
GRILL REGISTER AND DIFFUSER SCHEDULE
17'. !
trC?
TAG
MAKE AND MODEL
SIZE
NOTES
SD -1
PRICE SPD
24" X 2411
ATTACH TO GRID_
SD -2
PRICE SMCD
0r' X 1011
10 11
0"
SHEETROCK
RG -1
PRICE 80
12" X 24"
ATTACH TO GRID
RG -2
PRICE 80
24" X 24"
ATTACH TO GRID
EG -1
PRICE 80
12" X 24"
ATTACH TO GRID
EG -2
PRICE SMCD
6" X 6"
SHEETROCK
EG -2
PRICE SMCD
10" X 1011
0"
SHEETROCK
HVAC ABBREVIATIONS
AFF
ABOVE FINISHED FLOOR
AHU
AIR HANDLING UNIT
BDD
BACKDRAFT DAMPER
BPD
BY-PASS DAMPER
BTUH
BRITISH THERMAL UNIT PER HOUR
CD
CEILING DIFFUSER
CFM
CUBIC FEET PER MINUTE
DB
DECIBAL
DH
DUCT HEATER
EA
EXHAUST AIR
EER
ENERGY EFFICIENCY RATIO
EG
EXHAUST GRILLE
ESP
EXTERNAL STATIC PRESSURE
EXH
EXHAUST
FCU
FAN COIL UNIT
FD
FIRE DAMPER, FLOOR DRAIN
FPM
FEET PER MINUTE
FSD
FIRE AND SMOKE DAMPER
GF
GAS FURNACE
GRD
GRILLE, REGISTER, DIFFUSER
OR:
0- tat
e Electrical
Ff.Plumbing
(Gas Piping
City of Tukwila
ILDING Dlyl 1
HVAC ABBREVIATIONS
HP HORSEPOWER, HEAT PUMP
HVAC HEATING, VENTILATING, AND AIR CONDITIONING
NTS NOT TO SCALE
OBD OPPOSED BLADE DAMPER
OD OUTSIDE DIMENSION OR DIAMETER
OSA OUTSIDE AIR
OU OUTDOOR UNIT
RG RETURN GRILLE
RPM REVOLUTIONS PER MINUTE
RA RETURN AIR
SA SUPPLY AIR
SG SUPPLY GRILLE
SP STATIC PRESSURE
TG TRANSFER GRILLE
VAV VARIABLE AIR VOLUME
VFD VARIABLE FREQUENCY DRIVE
VTR VENT TO ROOF
VVT VARIABLE VOLUME AND TEMPERATURE
ZD ZONE DAMPER
HVAC LEGEND
SYMBOL
DESCRIPTION
H
SUPPLY DIFFUSER
F-
RETURN GRILLE
+
DAMPER
O
THERMOSTAT
O
SENSOR
p(1)
EXHAUST FAN
Z
EXHAUST GRILLE
CONDENSING UNIT
0
INLINE EXHAUST FAN
ROOFTOP EXHAUST FAN
_j
SIDEWALL EXHAUST FAN
®
SUPPLY GRILLE
<
VAV FAN BOX
CEILING EXHAUST FAN
®
GAS METER
[�
WT DAMPER
FM
T -BAR SUPPLY DIFFUSER
E]
T -BAR RETURN GRILLE
f
1ff��Il
CEILING RADIATION
DAMPER ABOVE DIFFUSER
El
CEILING RADIATION
DAMPER ABOVE GRILLE
FDO
FIRE DAMPER
FSDIo
FIRE SMOKE DAMPER
Os
SMOKE DETECTOR
FLEXIBLE DUCT SARA
ROUND DUCT UP
ROUND DUCT DOWN
RTu
ROOFTOP UNIT
EF -1
EXHAUST FAN
SF -1
SUPPLY FAN
UH -1
UNIT HEATER
TRH -1
INFRARED HEATER
HP -1
HEAT PUMP
AC -1
AIR CONDITIONING UNIT
AHU-1
AIR HANDLING UNIT
HVAC NOTES
1. DUCT CONSTRUCTION, SEALING, AND INSULATION
TO MEET REQUIREMENTS OF SECTION
C403.2.9 OF THE 2015 WSEC. ALL DUCTWORK
SHOWN IS LOW PRESSURE UNLESS INDICATED
OTHERWISE.
2. SMOKE DETECTOR(S) INSTALLED IN MAIN RETURN
AS PER SECTION 606 OF THE 2015 IMC. HVAC
SMOKE DUCT DETECTORS SHALL SHUT DOWN
POWER TO THE UNIT UPON ACTIVATION AND, A
"SUPERVISOR " ZONE SHALL BE INITIATED AT THE
FIRE ALARM PANEL UPON SMOKE DUCT
DETECTOR ACTIVATION. IMC SECTION, 606.2.1
3. EQUIPMENT INSTALLATION INSTRUCTIONS TO BE
ON SITE FOR INSPECTIONS.
4. ALL HVAC EQUIPMENT TO BE LABELED TO THE
SPACE SERVED.
5. DUCTS TO BE SUPPORTED AT EACH DIRECTION
CHANGE - VERTICAL AT 12'-0" MAX., HORIZONTAL
AT 10'-0" MAX. WITH STRAP, OR 8'-0" MAX FROM
TRAPEZE SUPPORT.
6. SYSTEM CONTROLS TO MEET 2015 WSEC
SECTIONS 403.2.4.2/3
7. THE HVAC INSTALLATION SHALL BE COMPLETE
WHEN ALL SECTIONS OF 408 WSEC HAVE BEEN
SATISFIED. THIS SHALL INCLUDE AS -BUILT
DRAWINGS, SUBMITTALS, O&M MANUALS
SYSTEM BALANCE REPORT, AND COMMISSIONING
REPORT.
8. ALL ECONOMIZERS PROVIDED SHALL MEET 2015
WSEC SECTIONS C403.2.4.7, C403.3
9. ALL SUPPLY GRILLES TO HAVE VOLUME DAMPERS
FOR BALANCING OF SYSTEM UPON COMPLETION
10. ALL PIPING TO BE INSULATED ACCORDING TO
2015 IEC C402.10
11. FRESH AIR INTAKE AND RELIEF/EXHAUST, WILL BE
EQUIPPED WITH LOW LEAK, CLASS 1A MOTORIZED
DAMPERS THAT AUTOMATICALLY CLOSE DURING
UNOCCUPIED HOURS TO COMPLY WITH 2015 SEC
SECTION C402.4.5.2
xka.
3j
iiS
2
P.O. BOX 1 455
ONROE, WA
98272
206.510.4250
C)
00
H
>
F-
m
z
Z
p(1)
o
0
Q��
<
�-
_j
Y
<
T-
J
M0
�
M
APPROVAL STAMP
DRAWL BY:
KIRK OFFERDAHL
DRAWN FOR:
PRECISE HEATING & COOLING
DATE STARTED:
8/5/2016
DATE PLOTTED:
12/5/2016
SCALE:
REVISIONS:
/ / I DEC 0 . 201 1
DESCRIr11 t. lEVVED FOR
COVIfPM COMPLIANCE
APPROVED
JAN 06 2017
P2 -
SHEET -,I BUIL1 ING DIVISION
OF
M5
HVAC NOTES
O MANUAL BALANCING DAMPERS TO BE INSTALLED ON ALL SUPPLY DIFFU
O BYPASS DAMPER (BD -1) TO BE SIZED TO BYPASS DUCTWORK
HVAC - UPlp=2-`,LY AND RETURN SYSTEMS
SCALE: 1/411 = 11
APPROVAL STAMP
DRAWN BY:
KIRK OFFERDAHL
DRAViN FOR:
PRECISE HEATING & COOLING
DATE STARTED:
11/17/2016
DATE PLOTTED:
12/5/2016
SCALE: 1/4 to = 1'
REVISIONS:
NOW
klr
zl?•
APPROVED
w.
RECEIVED
CITY OF TUKWILA OF
DEC 05 2016 M5
PERMIT CENTER
HVAC NOTES
O BALANCING DAMPERS TO BE INSTALLED ON ALL EXHAUST GRILLES
Q INSTALL BALANCING DAMPERS IN DUCT DIRECTLY ABOVE AND DIFFUSER
0001111
<Ali A
�r.
1455
s�
�� ��r� �� MSN ROE, WA
Q, 98272
2 206.510.4250
O
— 2 2
XX
O. 0 . T T
0 0 -
,y
C O.:
rf,
c 2
0-1
4 � S
i
TQ T
<.
o:_ o.-. o: 0r co
a
° ° 0 0 9c ry m
0 0- LLQ v) Co
C) 00
O � �..
. : 000
T:
0 �0 � =baa j
1.
w
o
5�
0110 0 a— .�
y C co
01
w�w'� f iia �
„ -
11,11 -o:�
T T C�
L
glmmm0 o
I
I
o
0 _ =
at
�� CO
0
MK—u 0APPROVAL STAMP
9c
'uff
�x {0�
4
1�� �� O
.� /�
74, 7t—
IF, 0 � �a 0
0 — 0 0
o 0 ° 0
0
DRAWN BY:
T c O �� 1, KIRK OFFERDAHL
T T �T DRAWN FOR:
PRECISE HEATING & COOLING
C
DATE STARTED:
: A
11/17/2016
0 0
0 0 0:: o_ o 0_1 o o: o _ o, o: o:; 0 0,
DATE SLOTTED:
12/5/2016
c
T SCALE:
T
nT
T T ..,., 1 4 1
°101
=- REVISIONS:
0 ° 0 Q 0 O
5132
S
. �o _
r
O;_ O.� DES
cR •
a
INK D FOR
w PRO RE— L
WORAPPROVEDr � INCE
3: to Ing womilgilm
JAN 0 6 2017
a
SHEET: i 0 u i a
H v Au" Rmm%CP®EX"oF1'AUzr3T SYSI'EM BUIL IN VISION
4 IT
RECEIVED
1
SCALE: 1/4" = 1' CITY OF TUKWILA
DECU 0 5 2016
OF
PERMIT CENTER M 5
I�
�
IMC 2015 MINIMUM VENTILATION REQUIREMENTS
ROOM TYPE lAREAlQTY OCC. LOAD # PEOPLE OSA/PERSON OSA SUPPLY RETURN EXHAUST
BREAK ROOM 210 1 25 PER 1000 SF 6 20 118 250 - 250
MENS 52 1 - - - - - - 70
WOMENS 220 1 - - - - 250 - 210
CORRIDOR 1650 1 0.06 CFM/SF - - 99 400 300 -
ENTRY 60 1 0.06 CFM/SF - - 4 200 - -
SMALL STUDIO 110 28 25 PER 1000 SF 3 20 69 200 200 70
MEDIUM STUDIO 150 6 25 PER 1000 SF 4 20 93 250 250 100
LARGE STUDIO 210 4 25 PER 1000 SF 5 20 130 330 330 140
JANITORS CLOSET 10 1 1 1 - - - I - I - I - 1 100
ZONE DAMPER SCHEDULE
SYMBOL SIZE MODEL COMMENTS
ZD 1-1 8" AZ 2 -300 -RI -XX PROVIDE CONTROL POWER
ZD 1-2 8" AZ 2 -300 -RI -XX PROVIDE CONTROL POWER
ZD 1-3 8" AZ 2 -300 -RI -XX PROVIDE CONTROL POWER
ZD 1-4 10" AZ 2 -300 -RI -XX PROVIDE CONTROL POWER
ZD 1-5 8" AZ 2 -300 -RI -XX PROVIDE CONTROL POWER
BD 1 14" AZ 2 -300 -RI -XX PROVIDE CONTROL POWER
ZD 2-1 8" AZ 2 -300 -RI -XX PROVIDE CONTROL POWER
ZD 2-2 8" AZ 2 -300 -RI -XX PROVIDE CONTROL POWER
ZD 2-3 8" AZ 2 -300 -RI -XX PROVIDE CONTROL POWER
ZD 2-4 8" AZ 2 -300 -RI -XX PROVIDE CONTROL POWER
ZD 2-5 10" AZ 2 -300 -RI -XX PROVIDE CONTROL POWER
ZD 2-6 10" AZ 2 -300 -RI -XX PROVIDE CONTROL POWER
ZD 2-7 8" AZ 2 -300 -RI -XX PROVIDE CONTROL POWER
ZD 2-8 8" AZ 2 -300 -RI -XX PROVIDE CONTROL POWER
ZD 2-9 8" AZ 2 -300 -RI -XX PROVIDE CONTROL POWER
ZD 2-10 8" AZ 2 -300 -RI -XX PROVIDE CONTROL POWER
ZD 2-11 10" AZ 2 -300 -RI -XX PROVIDE CONTROL POWER
ZD 2-12 10" AZ 2 -300 -RI -XX PROVIDE CONTROL POWER
BD 2 16" AZ 2 -300 -RI -XX PROVIDE CONTROL POWER
ZD 3-1 8" AZ 2 -300 -RI -XX PROVIDE CONTROL POWER
ZD 3-2 8" AZ 2 -300 -RI -XX PROVIDE CONTROL POWER
ZD 3-3 8" AZ 2 -300 -RI -XX PROVIDE CONTROL POWER
ZD 3-4 10" AZ 2 -300 -RI -XX PROVIDE CONTROL POWER
ZD 3-5 10" AZ 2 -300 -RI -XX PROVIDE CONTROL POWER
ZD 3-6 10" AZ 2 -300 -RI -XX PROVIDE CONTROL POWER
ZD 3-7 8" AZ 2 -300 -RI -XX PROVIDE CONTROL POWER
ZD 3-8 8" AZ 2 -300 -RI -XX PROVIDE CONTROL POWER
ZD 3-9 8" AZ 2 -300 -RI -XX PROVIDE CONTROL POWER
ZD 3-10 10" AZ 2 -300 -RI -XX PROVIDE CONTROL POWER
BD 3 16" AZ 2 -300 -RI -XX PROVIDE CONTROL POWER
ZD 4-1 8" AZ 2 -300 -RI -XX PROVIDE CONTROL POWER
ZD 4-2 8" AZ 2 -300 -RI -XX PROVIDE CONTROL POWER
ZD 4-3 10" AZ 2 -300 -RI -XX PROVIDE CONTROL POWER
ZD 4-4 8" AZ 2 -300 -RI -XX PROVIDE CONTROL POWER
ZD 4-5 8" AZ 2 -300 -RI -XX PROVIDE CONTROL POWER
ZD 4-6 8" AZ 2 -300 -RI -XX PROVIDE CONTROL POWER
ZD 4-7 8" AZ 2 -300 -RI -XX PROVIDE CONTROL POWER
ZD 4-8 8" AZ 2 -300 -RI -XX PROVIDE CONTROL POWER
ZD 4-9 8" AZ 2 -300 -RI -XX PROVIDE CONTROL POWER
ZD 4-10 8" AZ 2 -300 -RI -XX PROVIDE CONTROL POWER
ZD 4-11 10" AZ 2 -300 -RI -XX PROVIDE CONTROL POWER
ZD 4-12 10" AZ 2 -300 -RI -XX PROVIDE CONTROL POWER
ZD 4-13 8" AZ 2 -300 -RI -XX PROVIDE CONTROL POWER
BD 4 16" AZ 2 -300 -RI -XX PROVIDE CONTROL POWER