Loading...
HomeMy WebLinkAboutPermit M16-0194 - CITY TRANSFER - RTUCITY TRANSFER 11222 E MARGINAL WAY S EXPIRED 07/17/17 Ml 6=01 94 City of Tukwila • Department of Community Development • 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Inspection Request Line: 206-438-9350 Web site: http://www.TukwilaWA.gov MECHANICAL PERMIT Parcel No: 1023049001 Permit Number: M16-0194 Address: 11222 E MARGINAL WAYS Issue Date: 1/18/2017 Permit Expires On: 7/17/2017 Project Name: CITY TRANSFER Owner: Name: SEBCO INC 2015 Address: 4020 E MADISON #320, SEATTLE, WA, 2014 98112 2015 Contact Person: 2014 Name: MARK SMELTZER Phone: (425) 251-0356 Address: 1012 CENTRAL AVE S, KENT, WA, 2014 98032 2015 Contractor: 2015 Name: PERFORMANCE HEATING & A/C INC Phone: (425) 251-0356 Address: 1012 CENTRAL AVE S, KENT, WA, 98032 c License No: PERFOHA15ORT Expiration Date: 4/30/2017 Lender: Name: Address: DESCRIPTION OF WORK: RTU -1023049001 Valuation of Work: $8,900.00 Fees Collected: $311.22 Type of Work: NEW Electrical Service Provided by: SEATTLE CITY LIGHT Fuel type: GAS Water District: TUKWILA Sewer District: VALLEY VIEW Current Codes adopted by the City of Tukwila: International Building Code Edition: 2015 National Electrical Code: 2014 International Residential Code Edition: 2015 WA Cities Electrical Code: 2014 International Mechanical Code Edition: 2015 WAC 296-46B: 2014 Uniform Plumbing Code Edition: 2015 WA State Energy Code: 2015 International Fuel Gas Code: 2015 Permit Center Authorized Signature: c — Date: `1 v I hearby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this development permit and agree to the coditions attached to this permit. // G Signature: ;�2� Date: I / (O �� Print Name: This permit shall become null and void if the work is not commenced within 180 days for the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. PERMIT CONDITIONS: 1: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. 2: ***MECHANICAL PERMIT CONDITIONS*** 3: All mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center (206/431-3670). 4: All permits, inspection record card and approved construction documents shall be kept at the site of work and shall be open to inspection by the Building Inspector until final inspection approval is granted. PERMIT INSPECTIONS REQUIRED Permit Inspection Line: (206) 438-9350 1800 MECHANICAL FINAL 0701 ROUGH -IN MECHANICAL CITY OF TUKW1- . Community Development Department Permit Center • 6300 Southeenter Blvd., Suite 100 Tukwila, WA 98188 �' http://www.TukwilaWA.gov Mechanical Permit No. Project No. Date Application Accepted: Date Application Expires: 1 MECHANICAL PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. **please print** SITE LOCATION King Co Assessor's Tax No.. 102304-9001 Site Address: 11222 East Marginal Way South Suite Number: NA Floor: Roof Tenant Name: City Transfer New Tenant: ❑ .....Yes ®..No PROPERTY OWNER Name: SEBCO INC Address: PO Box 130940 City: 4020 E MADISOb State: wa Zip: 98112 Sr -A -KILT; CONTACT PERSON — person receiving all project communication Name: Mark Smeltzer Address: 1012 Central Ave. S. City: Kent State: WA Zip: 98032 Phone: (425) 251-0356 Fax: (253) 867-5775 Email: mark@pmghvac.com Valuation of project (contractor's bid price): $ Describe the scope of work in detail: 1023049001 Use: Residential: New .......... ❑ Commercial: New .......... 1z MECHANICAL CONTRACTOR INFORMATION Company Name: Performance Mechanical Group Address: 1012 Central Ave. S. City: Kent State: WA Zip: 98032 Phone: (425) 251-0356 Fax: (253) 867-5775 Contr Reg No.: PERFOHA15ORT Exp Date: 04/30/2017 Tukwila Business License No.: BUS -0994165 •11 Replacement ........ ❑ Replacement ........ ❑ Fuel Type: Electric..... ❑ Gas ....... ® Other: H:Upplications,Fort -Applications On Line\2016 ApplicationsWechanical Permit Application Revised 1-4-16.docx Revised: January 2016 bh Page] of 2 Indicate type of mechanical work being installed and the quantity below: Unit Type Qty Furnace <100k btu Residential, Nighttime Furnace >1 OOk btu Industrial Floor furnace 55 dB(A) Suspended/wall/floor mounted heater 57 dB(A) Appliance vent Commercial Repair or addition to heat/refrig/cooling system 47 dB(A) Air handling unit <I0,000 cfm 1 Unit Type Qty Air handling unit 210,000 cfm Residential, Nighttime Evaporator cooler Industrial Ventilation fan connected to single duct 55 dB(A) Ventilation system 57 dB(A) Hood and duct Commercial Incinerator — domestic 47 dB(A) Incinerator — comm/industrial 65 dB(A) Unit Type Qty Fire damper Residential, Nighttime Diffuser Industrial Thermostat 55 dB(A) Wood/gas stove 57 dB(A) Emergency enerator Commercial Other mechanical equipment 47 dB(A) 60 dB(A) 65 dB(A) Boiler/Compressor Qty 0-3 hp/100,000 btu 3-15 h /500,000 btu 15-30 hp/1,000,000 btu 30-50 hp/1,750,000 btu 50+hp/1,750,000 btu Noise: Mechanical units need to be in compliance with the Tukwila Noise Code. Maximum permissible sound levels are based on from where the sound is created and where the sound is heard. Additionally, if sound can be heard from within a house at night in a residential zone it may not be allowed. For more details, see TMC 8.22 District of Sound Producing Source District of Receiving Property Residential, Daytime* Residential, Nighttime Commercial Industrial Residential 55 dB(A) 45 dB(A) 57 dB(A) 60 dB(A) Commercial 57 dB(A) 47 dB(A) 60 dB(A) 65 dB(A) Industrial 60 dB(A) 50 dB(A) 65 dB(A) 70 dB(A) *Daytime means 7AM-1 OPM, Monday through Friday and 8AM-1 OPM, Saturday, Sunday and State -recognized holidays. A few sounds are exempt from the noise code, including: Warning devices; Construction and property maintenance during the daytime hours (lam-IOpm); Testing of backup generators during the day. PERMIT APPLICATION NOTES - Value of construction — in all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the permit center to comply with current fee schedules. Expiration of plan review — applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The building official may grant one extension of time for additional periods not to exceed 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER OR AUTHORIZED AGENT Signature: Print Name: Mark Smeltzer Mailing Address: 1012 Central Ave. S. Date: 12/21/2016 Day Telephone: (425) 251-0356 Kent WA 98032 City State Zip H:tApplications%Fonns-Applications On Line\2016 ApplicationsWechanical Permit Application Revised 1-4-16.docx Revised: January 2016 Page 2 of 2 bh DESCRIPTIONS PAID PermitTRAK $311.22 M16-0194 Address: 11222 E MARGINAL WAY S Apn: 1023049001 $311.22 MECHANICAL $299.25 PERMIT ISSUANCE BASE FEE R000.322.100.00.00 0.00 $32.50 PERMIT FEE R000.322.100.00.00 0.00 $206.90 PLAN CHECK FEE R000.322.102.00.00 0.00 $59.85 TECHNOLOGY FEE $11.97 TECHNOLOGY FEE TOTAL FEES PAID BY RECEIPT: R10110 R000.322.900.04.00 0.00 $11.97 Date Paid: Thursday, December 22, 2016 Paid By: BARRETT ROBERTS Pay Method: CREDIT CARD 867522 Printed: Thursday, December 22, 2016 11:50 AM 1 of 1 SYSTEMS STRUCTURAL CALCULATIONS 16-025-26 PMG - City Transfer RTU 11222 East Marginal Way South Tukwila, WA 98168 for PMG November 28, 2016 R� D FOR CODE PRRMPI OVED LIANCE JAN 0 6 2011 City of Tukwila BUIL ION _.__ a CITY OF TUKWILA DEC 2 2 20% PERMIT CENTER IL Ate I 1 i 1201 First Avenue South, Suite 310 Seattle, Washington 98134 206-402-5156 www.lundopsahl.com Project Address: Design Code: Project Description: Project PMG - City Transfer RTU Sheet ; Subject Overturning Client Performance Mechanical Group Page No. 1 ; Designer DCD Date 11/28/16 www.lundopsahlxc m Tel: 206.402.5156 11222 East Marginal Way South Tukwila, WA 98168 2012 IBC ASCE 7-10 Review existing structure to support new mechanical unit Provide seismic anchorage for the new unit Mechanical Unit Information (provided by Client) Unit Tag (e) Wei ht (n) Weight % Change Note RTU 403 lbs 405 lbs 0.5% Doesn't increase by more than 5%, no further review required. "Note: Mechanical Unit Weights were provided by Client. Lund Opsahl takes no responsibility if incorrect unit weights were provided ummary he framing supporting the above mentioned units were checked for the additional weight added the roof structure to verify demand on the existing framing does not exceed 5% per IBC hapter 34. For members that had their demand increase by more that 5% additional strength 3Iculations were performed to verify the member has adequate capacity to support the unit. he above mentioned mechanical units were reviewed for overturning forces from wind and ismic loading. Calculations verifying PMG's proposed anchorage are included. e proposed anchorage of the units is acceptable. Project PMG - City Transfer RTU Sheet Subject Overturning Performance Mechanical Group p Page No. 2 � _Designer DCD Date 11/28/16 www.lundopsahlxc m Tel: 206.402.5156 Seismic Design Criteria [ASCE 7-10 Chapter 13] Risk Category = II Site Class = D ap = 2.5 RP = 6 1p = 1 Ss = 1.5g Fa = 1 SMS = Fax Ss = 1.5g Sds = 2/3 x Sms = 1.0g z/h = 1.0g Lateral Seismic Force. Fp _ 0.4RpPlp i (1+2 h) _ .500Wp P FPmax = 1.6SpslpWp = 1.600Wp Fpmt.a = 0.3SDsIpWp = .300Wp Vertical Seismic Force. Fp(-rt)=+/-0.2SDSWP = .200Wp Wind Design Criteria [ASCE 7-10 Chapter 29] [Table 1.5-1] [Assumed] [Table 13.6-1] [Table 13.6-1] [Section 13.1.3] [Figure 22-1; Worst Case for Washington] [Table 11.4-1] [Eq 11.4-1] [Eq 11.4-3] [Assumed] [Eq 13.3-1] <---Controls [Eq 13.3-2] [Eq 13.3-3] [Section 13.3.1] Avg Structure Roof Ht = 30 ft [Assumed] Risk Category = II Exposure = B [Section 26.7.3] Basic Wind Speed, Vuit = 110 mph [Figure 26.5-1] Kn = 1 [Section 26.8.2] Kd = 0.85 [Section 26.6] KZ = 0.7 [Table 29.3-1] qZ = 0.00256KZKnKdV2 qZ = 18.43 psf ASCE 7-10 Section 29.5 has two separate equations for buildings less than 60ft and more than 60ft the equation for buildings less than 60ft produces higher loads and will be used for all cases Horizontal Pressure Vertical Pressure Fh=gh(GCr)Af [Eq 29.5-2] F,,=gh(GCr)Af [Eq 29.5-3] GCr = 1.9 [Section 29.5.1] GCr = 1.5 [Section 29.5.1] Fh = 35.02 psf Fh = 27.65 psf SAHL Unit Information Tag: RTU -1 Weight: 405 Ibs Height: 3.13 ft Length: 3.79 ft Width: 13.46 ft Project PMG - City Transfer RTU Sheet Subject Overturning Performance Mechanical Group 3 Client P Page No. i Desiqner DCD Date 11/28/16 www.lundopsahl.c�m Tel: 206.402.5156 Seismic Loading \I/ Fp= 20�EFp(ve 405 Ibs +/- 81 Ibs = Width N Worst Cast Uplift ASD: 0.6D+0.7E = 29 lbs LRFD: 0.9D+E = 50 Ibs "Note negative values indicate uplift Wind Loading Fh= 415 Ibs D= 405 Ibs FV _ +/- 363 Ibs = Width N CY (Y Worst Cast Uplift 4� ASD: 0.6D+0.6W-1001bs I "Note negative values indicate uplift "Note our calculation checks overturning moment of the mechanical unit in the short direction(width). Reactions D E R1 R2203 Ibs -91 Ibs +/- 41 Ibs 203 lbs 91 Ibs +/- 41 Ibs Worst Case Compression ASD: D+0.7E = 295 Ibs LRFD: 1.2D+E = 375 Ibs Reactions D W R1 203 Ibs -187 Ibs +/- 181 Ibs R2 203 lbs 187 Ibs +/- 181 Ibs COMP. USED ON PAGE 5 Worst Case Compression ASD: D+0.6W = 4241bs LRFD: 1.2D+W = 6121bs UPLIFT USED ON PAGE 4 Project PMG - CITY TRANSFER RTU Sheet Subject OVERTURNING Page No. 4 UNDClient PERFORMANCE MECHANICL GROUP `— Project No. 3AHL Designer DCD oat. 11/28/16 www.lundopsahl.com I Tel: 206.402.5156 C RITERI.q uvilj = 40S L;S [FROM PAGE 71 U,PLI P-1 C K0 = -1CX) 4.35 C4 4A I L= PjWoj 12 GAUGE [FROM PAGE 61 U?L! t''ER IQGl.E= 10()L?,S/-2 ANGLES = '�,Cl LBS/AQUE L z"x2''x 11/1 1 G Gr, Si aE F E.Q # 1U ;C.REvJ To uuzT -w10 SCREWS iv cliptWEL Cq Lam, EA ANGLE] -T-1P. F--____— P 1 ODD C u AIJ rJ EA- -T . S/8'0 XS" LP6 SCREW @ Pfd CUR N t9 LKIi J& 1G GA. SnEET METAL(CGU r�tAEV w1 PM&) FGR ` wt- U, n, SI4EA-R =. 2 SCREWS X 370 Lf3SfiSCREu3 = -4G LAS ? S�jLRS TFtJs�.o�l = � sc�Ews x ►37 c.as/SCRtt� LA& ScRr--W To SLEIePER �sSu rnT�v F%R PER � DS I W = � 3 Lg5/ iN Of PEOE'1 RATTOQ I" LAG F:ti- 15/8 10,Ntt t L " E TG 14: = 1.3 O pvNuT�?J h G N VJ = ;9 3 L6S/DJ x 1, 3b)' = 335.39 L&S > SCS L&s 011 MTN. CEKnEF TO CEVTSR= 3X D -T -ANA 3 X 0.00'=0.571) M-1 ,J- EDGE 1)TST. = 1.S xISM, = I.S x0.1 (j-. z�S,r G.S'?" } 2(0,2F,5) = 1.t4L 1.S" L NG SCREW sPRc1N& = EDGE t7 -LST � 4D = 4 x 318 = 1,S)) 4'' SLF-1~PF.R- ---� (1. S") = 1" 0 Project PMG - CITY TRANSFER RTU Sheet Subject OVERTURNING Page No. 5 PERFORMANCE MECHANICL GROUP Tient Protect No. Designer DCD Date 11/28/16 www.lundopsahl.com I Tel: 206.402.5156 C0f,APRESSZe)N UN PIGGCG: cjpW1= 72!'=s—` M A X. ALLOW. tANTFOR NA L.CUHQ= SGO L?�,S A(TUAL< LOAD 0 1A LbS/CHAWWEL_; = a la L8S ala L9S, GC) L 6S ' • (rj7�) 'W4'95# i I X / v' o — 0 Z — jl I 2x6 na 2'-0"O.C., TYP. 'WI'134# 'W2'84# 0 /A5TEN RTq 4 TO NEW CHANNELS WITHL2x2x161GA. TYP. 9 EACH CORNER, FASTENAN LE TO CHANNEL WITH (2) #10 SCRE S. FASTENANGLE TO RTU -4 BASERAIL M 7TH(2) #10 SCREWS. (16) TOTAL #1 SCREWS. C I I NEW PI000 HANNEL TO SPANEXISTING 4x4 WO D SLEEPERS, TYP. OF(2) CHA NELS. FA5TENPI000 TO EXISTINGSL EPER WITH3/8x3" LAGBOL T. ) LAG @ EACHEND OFCHANNEL, (4)L465TOTAL. I I EX15TINGR )OFED-IN 4x4x76"LONG WOOD SLEE R FASTENED TO EXISTINGRQOFSTRUCTURE, TYP. OF(2) I W Figure 2. 4YCC4024-4036 -#1 (OUTSIDE) BACK DUCT OPENINGS SECT N TYPICAL (8) SIDES OF SIDEFLON DUCT OPENINGS Outline Drawings O LM I kot VAkt : t-e0&50At17.,eV-. 145.1121 (SURFACE AREA) BACK SIDE 313 �1*VP5. 3 Z Lt3 . 405 �bra. 530.60 [20.7/81 Height mm/in Flu Hood w/brkt mm/InWeight A D W1 Approx. Corner Weight - kg / lbs W2 W3 W4 Shipping kg/lbs Total Unit Weight kg/lbs Center of Gravity mm/in B C 4YCC4024 (060) 898.53 [35-3/8] 157.16 [6-3/16) 58.3 [129) 36.8 [81] 26.1 [58] 41.0 [90) 196.1 [432] 162.4 [358) 479.8 [18.9) 527.8 [20.8] 4YCC4030 (070) 898.53 [35-3/8] 157.16 [6-3/16) 61.3 [135] 38.7 [85] 27.5 [61] 43.1 (95] 204.8 [451] 171.1 [377] 406.5 [16.0] 594.1 [23.4] 4YCC4036 (070) 949.33 [37-3/8] 157.16 [6.3/16) 61.1 [134] 38.3 [84) 27.1 (60] 43.2 [95] 203.4 [438] 169.7 [374] 414.3 (16.3) 697.6 [27.5] 4YCC4036 (090) 949.53 [37-3/8] 157.16 [6.3/16] 61.7 [136] 38.9 (86] 27.7 161) 43.7 (96] 205.7 [453] 172.0 [379] 414.3 [16.3] 697.6 [27.5) 4YCC4036A-SUB-1 F -EN 5 Outline Drawings M 10• X41 18.03 18.29 123/321 123/321 14.22 191161 SECTION TYPICAL (8) SIDES OF DOWNFLOW DUCT OPENINGS Figure 1. 4YCC4024-4036 110-21/711 Note: The view labeled "Bottom side" represents the base as viewed looking up from underneath the unit. 4 OUTLET Ez LUE ODD 4YCC4036A-SUB-1 F -E N City of Tukwila Allan Ekberg, Mayor Department of Community Development Jack Pace, Director 6/5/2017 MARK SMELTZER 1012 CENTRAL AVE S KENT, WA 98032 RE: Permit No. M16-0194 CITY TRANSFER 11222 E MARGINAL WAY S Dear Permit Holder: In reviewing our current records, the above noted permit has not received a final inspection by the City of Tukwila Building Division. Per the International Building Code, International Mechanical Code, Uniform Plumbing Code and/or the National Electric Code, every permit issued by the Building Division under the provisions of these codes shall expire by limitation and become null and void if the building or work authorized by such permit has not begun within 180 days from the issuance date of such permit, or if the building or work authorized by such permit is suspended or abandoned at any time after the work has begun for a period of 180 days. Your permit will expire on 7/17/2017. Based on the above, you are hereby advised to: 1) Call the City of Tukwila Inspection Request Line at 206-438-9350 to schedule for the next or final inspection. Each inspection creates a new 180 day period, provided the inspection shows progress. -or- 2) Submit a written request for permit extension to the Permit Center at least seven(7) days before it is due to expire. Address your extension request to the Building Official and state your reason(s) for the need to extend your permit. The Building Code does allow the Building Official to approve one extension of up to 180 days. If it is determined that your extension request is granted, you will be notified by mail. In the event you do not call for an inspection and/or receive an extension prior to 7/17/2017, your permit will become null and void and any further work on the project will require a new permit and associated fees. Thank you for your cooperation in this matter. Sincerely, kacAeR ley Permit Technician File No: M16-0194 6300 Southcenter Boulevard Suite #100 9 Tukwila, Washington 98188 0 Phone 206-431-3670 • Fax 206-431-3665 �co� i t s o Y li EatORD MPY PLAN REVIEW/ROUTING SLIP PERMIT NUMBER: M16-0194 DATE: 12/23/16 PROJECT NAME: CITY TRANSFER SITE ADDRESS: 11222 E MARGINAL WAY S X Original Plan Submittal Response to Correction Letter #, Revision # before Permit Issued Revision # after Permit Issued DEPARTMENTS: 0 KYv& lit A'M Nor I� Building Division N Fire Prevention Planning Division ❑ Public Works ❑ Structural ❑ Permit Coordinator ❑ PRELIMINARY REVIEW: DATE: 12/27/16 Not Applicable ❑ Structural Review Required ❑ (no approval review required) REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: Approved ❑ Corrections Required ❑ (corrections entered in Reviews) Notation: 1 SNI 1��V I REVIEWER'S INITIALS: DUE DATE: 01/24/17 Approved with Conditions ❑ Denied ❑ (ie: Zoning Issues) DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: 12/18/2013 PERFORMANCE HEATING & A/C INC Page 1 of 2 Home Espanol Contnet Search L&I e A -J index help My L &I Safety & Health Claims & Insurance Workplace Rights Trades & Licensing 10 Washington State Department of Labor & Industries PERFORMANCE HEATING & A/C INC Owner or tradesperson 1012 Central Ave S GENERAL KENT, WA 98032 Principals p 425-251-0356 MILLER, DANIEL E, PRESIDENT KING County ERDAHL, DARRIN, VICE PRESIDENT Effective date GOWIN, RICHARD L, VICE PRESIDENT 04/28/2016 (End: 04/26/2011) Expiration date Help us improve GOWIN, CONSTANCE F, VICE PRESIDENT $12,000.00 (End: 11/15/2007) Doing business as PERFORMANCE HEATING & A/C INC WA UBI No. Business type 600 601 386 Corporation Governing persons DANIEL E MILLER DARRIN P ERDAHL; License Verify the contractor's active registration / license / certification (depending on trade) and any past violations. Construction Contractor. Active. .......................................................................... Meets current requirements. License specialties GENERAL $1,000,000.00 License no. PERFOHA15ORT Effective — expiration Effective date 12/30/1985— 04/30/2017 04/28/2016 Bond ......._.... Expiration date Help us improve DEVELOPERS SURETY & INDEM CO $12,000.00 Bond account no. 748802C Received by L&I Effective date 11127/2007 10/01/2007 Expiration date Until Canceled Insurance ..............._....._ AMCO Ins Co $1,000,000.00 Policy no. GLA03007606389 Received by L&I Effective date 04/26/2016 04/28/2016 Expiration date Help us improve https://secure.Ini.wa.gov/verify/Detail.aspx?UBI=600601386&LIC=PERFOHA15ORT&SAW= 1/18/2017 PERFORMANCE HEATING & A/C INC Page 2 of 2 04/28/2017 Insurance history Savings N"O", .. ....... No savings accounts during the previous 6 year period. Lawsuits against the bond or_savings No lawsuits against the bond or savings accounts during the previous 6 year period. L&I Tax debts No L&I tax debts are recorded for this contractor license during the previous 6 year period, but some debts may be recorded by other agencies. License Violations ................_...................................... No license violations during the previous 6 year period. Workers' comp Do you know if the business has employees? If so, verify the business is up-to-date on workers' comp premiums. L&I Account ID Account Is current. 494,599-00 ................................. Doing business as PERFORMANCE HEATING & AIR COND Estimated workers reported Quarter 3 of Year 2016 "51 to 75 Workers" L&I account representative T1 / NICHOLE CAROW (360)902-5634 - Email: CANI235@lni.wa.gov Workplace safety and health Check for any past safety and health violations found on jobsites this business was responsible for. Inspection results date 12/04/2015 No violations Inspection no. 317938325 Location 3600 15th Ave W Seattle, WA 98119 J Washington State Dept. of Labor & Industries. Use of this site is subject to the laws of the state of Washington. Help us improve https:Hsecure.lni.wa.gov/verifyIDetail.aspx?UBI=600601386&LIC=PERFOHA15ORT&SAW= 1/18/2017