Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Permit EL16-0016 - BEST BUY - RELOCATION OF LIGHTING
BEST BUY 17364 SOUTHCENTER PKWY EL16-0016 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Inspection Request Line: 206-438-9350 Web site: http://www.TukwilaWA.Rov ELECTRICAL PERMIT Parcel No: 2623049110 Permit Number: EL16-0016 Address: 17364 SOUTHCENTER PKWY Issue Date: 3/18/2016 International Residential Code Edition: Permit Expires On: 10/8/2016 Project Name: BEST BUY 2014 Owner: 2012 Name: KI R TU KWI LA 050 LLC 2014 Address: 3333 NEW HYDE PARK RD #100 C/O 2012 KIMCO REALTY CORP, PO BOX 5020 2012 NEW HYDE PK, CO, 11042 2012 Contact Person: Name: LINDSEY FLEENER Phone: (303) 472-4773 Address: 999 18TH ST SUITE 3000, DENVER, Date: l��y CO,80401 Contractor: Name: ABACUS ELECTRIC CO Phone: (253) 984-1611 Address: PO BOX 1030, MILTON, WA, 98354 License No: ABACUEC928LT Expiration Date: 6/30/2016 Lender: Name: Address: DESCRIPTION OF WORK: RELOCATION OF LIGHTING ON EXISTING SALES FLOOR. ADDING (12) NEW LIGHT FIXTURES & RETAIL DISPLAY. ADDING (68) LOW VOLTAGE DROPS THROUGHOUT Valuation of single family: $0.00 Fees Collected: $1,339.98 Valuation of mf/comm: $54,000.00 Type of Work: TENANT IMP Electrical Service Provided by: PUGET SOUND ENERGY Water District: HIGHLINE,TUKWILA Sewer District: TUKWILA SEWER SERVICE Current Codes adopted by the City of Tukwila: International Building Code Edition: 2012 National Electrical Code: 2014 International Residential Code Edition: 2012 WA Cities Electrical Code: 2014 International Mechanical Code Edition: 2012 WAC 296-4613: 2014 Uniform Plumbing Code Edition: 2012 WA State Energy Code: 2012 International Fuel Gas Code: 2012 Permit Center Authorized Signature: _ Date: l��y I hearby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this development per m't and agree to the conditions attached to this permit. Signature: Date: Print Name: w This permit shall become null and void if the work is not commenced within 180 days for the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. PERMIT CONDITIONS: 1: 'ELECTRICAL PERMIT CONDITIONS' 2: A copy of the electrical work permit shall be posted or otherwise made readily accessible to the Electrical Inspector at each work site. 3: Approved plans shall be maintained at the construction site and shall be readily available to the Electrical Inspector. 4: All electrical work shall be in accordance with NFPA 70 - NEC, and requirements for electrical installations, Chapter 296-46B WAC. 5: When any portion of the electrical installation is to be hidden from view by permanent placement of parts of the building, such equipment shall not be concealed until it has been inspected and approved by the Electrical Inspector. 6: The issuance of an electrical work permit shall not be construed to be a permit for, or an approval of, any violation of the provisions of the electrical code or other ordinances of the jurisdiction. Permits or related documentation that presumes to grant this authority are therefore not valid. 7: Any change in the scope of work described by the electrical work permit shall require additional work permits. Where approved plans have been issued, revisions to the plans and additional review may be required. PERMIT INSPECTIONS REQUIRED Permit Inspection Line: (206) 438-9350 2100 ELECTRICAL FINAL 7003 ROUGH -IN ELECTRICAL 7003 ROUGH -IN ELECTRICAL 7002 SERVICE 7001 UNDERGROUND/SLAB City of Tukwila • Department of Community Development • 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Inspection Request Line: 206-438-9350 Web site: http://www.TukwilaWA.eov ELECTRICAL PERMIT Parcel No: 2623049110 Permit Number: EL16-0016 Address: 17364 SOUTHCENTER PKWY Issue Date: 3/18/2016 Permit Expires On: 9/14/2016 Project Name: BEST BUY Owner: Name: KI R TU KWI LA 050 LLC Address: 3333 NEW HYDE PARK RD #100 C/O DESCRIPTION OF WORK: Phone: (303) 472-4773 Phone: (262) 638-6000 Expiration Date: 4/15/2017 RELOCATION OF LIGHTING ON EXISTING SALES FLOOR. ADDING (12) NEW LIGHT FIXTURES & RETAIL DISPLAY. ADDING (68) LOW VOLTAGE DROPS THROUGHOUT Valuation of single family: $0.00 Fees Collected: $1,339.98 Valuation of mf/comm: $54,000.00 Type of Work: TENANT IMP Electrical Service Provided by: PUGET SOUND ENERGY Water District: HIGH LINE,TUKWILA Sewer District: TUKWILA SEWER SERVICE Current Codes adopted by the City of Tukwila: International Building Code Edition: KIMCO REALTY CORP, PO BOX 5020 National Electrical Code: NEW HYDE PK, CO, 11042 Contact Person: 2012 Name: LINDSEY FLEENER Address: 999 18TH ST SUITE 3000, DENVER, WAC 296-4613: CO, 80401 Contractor: 2012 Name: HORIZON RETAIL CONSTRUCTION INC Address: 1500 HORIZON DR, STURTEVANT, WI, 53177 License No: HORIZRC072N5 Lender: Name: Address: kk DESCRIPTION OF WORK: Phone: (303) 472-4773 Phone: (262) 638-6000 Expiration Date: 4/15/2017 RELOCATION OF LIGHTING ON EXISTING SALES FLOOR. ADDING (12) NEW LIGHT FIXTURES & RETAIL DISPLAY. ADDING (68) LOW VOLTAGE DROPS THROUGHOUT Valuation of single family: $0.00 Fees Collected: $1,339.98 Valuation of mf/comm: $54,000.00 Type of Work: TENANT IMP Electrical Service Provided by: PUGET SOUND ENERGY Water District: HIGH LINE,TUKWILA Sewer District: TUKWILA SEWER SERVICE Current Codes adopted by the City of Tukwila: International Building Code Edition: 2012 National Electrical Code: 2014 International Residential Code Edition: 2012 WA Cities Electrical Code: 2014 International Mechanical Code Edition: 2012 WAC 296-4613: 2014 Uniform Plumbing Code Edition: 2012 WA State Energy Code: 2012 International Fuel Gas Code: 2012 Permit Center Authorized Signature: VAlk kk Date: . '� I hearby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this development permit and agree to the conditions attaghed to this permit. Signature: Print Nam Date: This permit shall become null and void if the work is not commenced within 180 days for the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. PERMIT CONDITIONS: 1: 'ELECTRICAL PERMIT CONDITIONS' 2: A copy of the electrical work permit shall be posted or otherwise made readily accessible to the Electrical Inspector at each work site. 3: Approved plans shall be maintained at the construction site and shall be readily available to the Electrical Inspector. 4: All electrical work shall be in accordance with NFPA 70 - NEC, and requirements for electrical installations, Chapter 296-46B WAC. 5: When any portion of the electrical installation is to be hidden from view by permanent placement of parts of the building, such equipment shall not be concealed until it has been inspected and approved by the Electrical Inspector. 6: The issuance of an electrical work permit shall not be construed to be a permit for, or an approval of, any violation of the provisions of the electrical code or other ordinances of the jurisdiction. Permits or related documentation that presumes to grant this authority are therefore not valid. 7: Any change in the scope of work described by the electrical work permit shall require additional work permits. Where approved plans have been issued, revisions to the plans and additional review may be required. PERMIT INSPECTIONS REQUIRED Permit Inspection Line: (206) 438-9350 2100 ELECTRICAL FINAL 7003 ROUGH -IN ELECTRICAL 7002 SERVICE 7001 UNDERGROUND/SLAB CITY OF TUKWILA Community Development Department Permit Center • 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 htW://www.TukwilaWA.gov Electrical Permit No. � � ' On Project No. Date Application Accepted: Date Application Expires: or office use only) ELECTRICAL PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. "Please Print" SITE LOCATION 71 King Co Assessor's Tax No.: Site Address: 193LLI Sbulmu`l er r UJ T Suite Number: Floor: Tenant Name: 1&LSy �U1 New Tenant: ❑ .....Yes B"'No PROPERTY OWNER Name: Address: City: 17t State:Zip: ?W8 CONTACT PERSON — person receiving all project communication Name: f. o n M Address: City: `V�� Stater Zip: . Phone: -0G&4-1L111 Fax. 5.3-SLA-IL013 Email: 0,0.Cot1 a0.�DQCUS2\e��rvc e• c urv. ELECTRICAL CONTRACTOR INFORMATION Company Name: C.a%l Address: O 66� X30 City: `V` _` _ State: VIA, Zip:n 3s Phone: aS Ca t Fax: aS _C�%L - l U 13 Contr Reg No.:Exp Date: 'A�AC.l.1.G�C9Z$Lj (o, 30 -1� Tukwila Business License No.; 3 �vO S i�f Qbkn,�A I. TAVI WIM 2s„3-6k-7mr Valuation of Project (contractor's bid price): $ ;a620 U Scope of Work (please provide detailed information): Sf O fY �2�t.c nOCIGt /�1 �� CiiA� 4t^� Will service be altered? ❑ Yes No Adding more than 50 amps? ❑ Yes JkrNo Type of Use: t& " -, 0, 1 I rA fa r, Type of work: ❑ New ❑ Addition ❑ Service Change ❑ Low Voltage ❑ Generator ❑ Fire Alarm Property Served by: ❑ Puget Sound Energy ❑ Seattle City Light HAApplicationsWomu-Applications On Line\2014 ApplicationsTIcorical Permit Application Revised 1-1-14.docx Revised: January 2014 bh dRemodel ❑ Tenant Improvement ❑ Telecommunication ❑ Temporary Service Page I of 2 RESIDENTIAL NEW RESIDENTIAL SERVICE ❑ New single family dwellings ................................... $152.85 (including an attached garage) ❑ Garages, pools, spas and outbuildings ........................ $81.90 ea ❑ Low voltage systems (alarm, furnace thermostat) ................................ $59.85 ea RESIDENTIAL REMODEL AND SERVICE CHANGES ❑ Service change or alteration ...................................... $81.90 (no added/altered circuits) ❑ Service change with added/altered circuits ................. $81.90 number of added circuits ....................... $11.55 ea ❑ Circuits added/altered without service change ...........$54.60 (up to 5 circuits) ❑ Circuits added/altered without service change ...........$54.60 (6 or more circuits)...............................................$7.65 ea ❑ Meter/mast repair ....................................................... $68.25 ❑ Low voltage systems ................................................. $59.85 (alarm, furnace thermostat) PERMIT APPLICATION NOTES - MULTI -FAMILY AND COMMERCIAL Fees are based on the valuation of the electrical contract. MISCELLANEOUS FEES ❑ Temporary service (residential) ................................. $65.00 ❑ Temporary service (generator) ................................... $80.90 ❑ Manufactured/mobile home service ........................... $86.25 (excluding garage or outbuilding) ❑ Carnivals.................................................................... $80.60 Number of concessions ......................... $10.80 ea Each ride and generator truck ............... $10.80 ea ***EFFECTIVE JANUARY 1, 2014 EACH PERMIT WILL BE ASSESSED A 5% TECHNOLOGY FEE* * * Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation The Building Official may grant one extension of time for an additional period not to exceed 90 days. The extension shall be requested in writing and justifiable cause demonstrated. I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER OR ELECTRICAL CONTRACTOR: Print Name: /4 a ✓VK�% Date: 3l 7—q �1 r Day Telephone: eRS 3-CC5 ti -1 to l l Mailing Address: �o Eb�l- Ci$ -?)Sy City State Zip H:4lpplications\Forms-Applications On Line\2014 ApplicationsWectrical Pcrmit Application Revised 1-1-14.docx Revised: January 2014 bh Page 2 of 2 DESCRIPTIONS PermitTRAK 1 $411.38 EL16-0016 Address: 17364 SOUTHCENTER PKWY Apn: 2623049110 $411.38 ELECTRICAL $395.56 PLAN CHECK FEE R000.345.832.00.00 0.00 $79.11 PERMIT FEE MULTI-FAM/COMM R000.322.101.00.00 0.00 $316.45 TECHNOLOGY FEE $15.82 TECHNOLOGY FEE TOTAL FEES PAID R000,322.900.04.00 0.00 $15.82 Date Paid: Thursday, March 24, 2016 Paid By: ABACO Pay Method: CHECK 15913 Printed: Thursday, March 24, 2016 12:39 PM 1 of 1 R SY57EM5 DESCRIPTIONS 1 PermitTRAK $772.15 EL16-0016 Address: 17364 SOUTHCENTER PKWY Apn: 2623049110 $772.15 ELECTRICAL $736.43 PLAN CHECK FEE R000.345.832.00.00 0.00 $22.13 PERMIT FEE MULTI-FAM/COMM R000.322.101.00.00 0.00 $714.30 TECHNOLOGY FEE $35.72 TECHNOLOGY FEE TOTAL FEES PAID R000.322.900.04.00 0.00 $35.72 Date Paid: Friday, March 18, 2016 Paid By: HORIZON Pay Method: CHECK 383048 Printed: Friday, March 18, 2016 10:51 AM 1 of 1 r-7? L ���srsreMS Date Paid: Wednesday, January 06, 2016 Paid By: CMA ARCHITECTURE Pay Method: CHECK 129712 Printed: Wednesday, January 06, 2016 11:49 AM 1 of 1 CRWSYS7EM5 INSPECTION RECORD Retain a copy with permit 6A -�o INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Project: Type of Inspection: Address: /� 1 Y 3 ti 1 Date Called: Special Instruction : Date Wanted: Requester: Phone No: 9 Approved per applicable codes. l..1 Corrections required prior to approval. Z nspector: Date: 0i l() REINSPECTIOP FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection, INSPECTION RECORD Retain a copy with permit®� INSPECTION NO. PER N0. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 w Project: + Type KnspectiI J Address: 73 Date Called: Special Instruction &: Date Wanted: a.m Requester: Phone No: MApproved per applicable codes. El Corrections required prior to approval. U paid at 6300 Southcenter Blvd., Suite 100. Catl to schedule reinspection. / INSPECTION RECORD % Retain a copy with permit INSPECTION NO. PERMIT N0. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd- #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Approved per applicable codes. L, Corrections required prior to approval. LJ paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. 2012 Washington State Energy Code Compliance Forms for Commercial Buildings including R2 & R3 over 3 storiesi and i= Project Info Project Address Best Buy- #447 Date C 0 D 9 9 QWMIA Compliance 17364 South Center Parkway For Bi ileFC forms do not Tukwila, WA 98188 require a ssword to password 1 3 2 16 Applicant Name: Jay Rohkohl Instructional and calculating cells s: 50th Sth 6th Stt Ste 1100, M Is., MN Applicant AddresSouth Street p Applicant Phone: are write- Project Description ❑ New Building ❑ Addition ❑ Alteration DIVISIO Lighting Compliance Path 0 Lighting Power Density Calculations O Total Building Performance (If Total Building Performance then only LGT-CHK is required.) Lighting Power Allowance Building Ar" VIEWEL./i o FO C* Space -By -Space Method fl Method Selection required to f �'�k �01 enable LPA forms COMPLIANCE WITH Interior Lighting System Retail S 3les wNFPAa7GL-afl&Gescer it light fixtures Q �pF WAS, O Description A J k 1 1 L 2u 13 CO Briefly describe lighting -0 system type and features. City ofTUWla Q/STERE s Additions and Change of Space Use 2 Addition area or Change of Space Use area complies with all applicable provisions as stand alone project ❑ Addition area is combined with existing building lighting systems to demonstrate compliance with all applicable provisions per C101.4.3 Provide Building Area Method (LTG -INT -BLD) or Space -By -Space Method (LTG -INT -SPACE) Compliance Form. Document maximum allowed and proposed (including existing if applicable) lighting wattage of Addition or Change of Use space. Provide applicable lighting controls per C405.2 and commissioning of lighting controls per C405.13. Alterations, Renovations and Repairs (C101.4.3.1) ❑ 60% or more of luminaires in space replaced Provide Building Area Method (LTG -INT -BLD) or Space -By -Space Method (LTG -INT -SPACE) Compliance Form. Document maximum allowed wattage within the lighting retrofit space in Maximum Allowed Wattage table and proposed (including existing) lighting wattage in Proposed Wattage table. Retrofit and non -retrofit spaces shall be documented separately using multiple forms. ❑✓ Less than 60% of luminaires in space replaced Provide a separate Space -By -Space Method (LTG -INT -SPACE) Compliance Form for this retrofit area. Document existing total wattage within the lighting retrofit space in cell provided in the Maximum Allowed Wattage table. Document proposed (including existing) lighting wattage in the Proposed Wattage table. ❑ Lamp and/or ballast replacement within existing luminaires only — existing total interior building wattage not increased ❑ New wiring installed to serve added fixtures and/or fixtures relocated to new circuit Provide applicable manual lighting controls (C405.2.1), occupancy sensors (C405.2.2.2), daylight zone controls (C405.2.2.3), specific application controls (C405.2.3), and commissioning of lighting controls per C405.13 ❑ New or moved lighting panel Provide all applicable lighting controls as noted for New Wiring, automatic time switch controls (C4D5.2.2.1), and commissioning of lighting controls per C405.13. ❑ Space is reconfigured - luminaires unchanged or moved only Provide all applicable lighting controls as noted for New Wiring and commissioning of lighting controls per C405.13. ❑ No changes are being made to the interior lighting and space use not changed. RECEIVED EL16,-- OD 10 U I Y UI- 1 UKWILA� JAN 0 6 2015 PERMIT CENTER • • • • . : • go g 2012 Washington State Energy Code Compliance Forms for Commercial Buildings including R2 & R3 over 3 stories and all R1 Revised Jan 2014 Project Address Best Buy- #447 Date 5/21/2013 Lighting Alterations, Renovations & Building Additions For Building Department Use O Less than 60% 0 60% or more 0 Stand alone Addition 29733 Notes: a. Lighting fixtures in a building addition may comply as a stand alone project, or they may be combined with the overall existing bldg lighting to demonstrate compliance. Refer to C 101.4.3. b. For retrofits and building additions, provide Space Types and gross interior areas in the Maximum Allowed Lighting table. If a builidng addition will comply as combined with the overall existing builidng, include all applicable existing Space Types and gross interior areas. c. Document new fixtures and all existing to remain fixtures in the Proposed Lighting table. d. If less than 60% of existing fixtures will be replaced, provide total existing lighting wattage (prior to retrofit) in the space provided in the Maximum Allowed Lighting table. Maximum Allowed Lighting Wattage Location (plan #, Allowed Gross Interior Watfs—Allowed room #) Space Type* Watts per ft2 Area in ft2 (watts/ft2 x area) Retail: Sales area 1.68 37553 63089 Retail Display Lighting from LTG -INT -DISPLAY 2808 Total Proposed Watts may not exceed Total Allowed Watts for Interior Lighting Atrium** Enter Height:,i 32541 Existing Lighting Enter Exist. Watts: Retail Display Allowance from LTG -INT -DISPLAY 2 574 * Select Table C405.5.2(2) category from drop down menu. ** For atriums, indicate height. Allowed wattage for first 40 feet is 0.03 W/ft. ht., above 40 feet is 0.02 W/ft. ht. Proposed Lighting Wattage Area Allowed Watts Total 37553 65663 Location (plan #, Number of room #) Fixture Description*** Fixtures Watts/ Fixture Watts Proposed Sales Area C - 2x4 Fluorescent (12 New Light Fixtures) 159 18.7 29733 Retail Display Lighting from LTG -INT -DISPLAY 2808 Total Proposed Watts may not exceed Total Allowed Watts for Interior Lighting Total Proposed Watt 32541 *** Include existing to remain lighting fixtures and exempt lighting equipment per notes below. Notes: 1. Include ALL proposed lighting fixtures. 2. For proposed Fixture Description, indicate fixture type, lamp type (e.g. T-8), number of lamps in the fixture, and ballast type (if included). For track lighting, list the length of the track (in feet) in addition to the fixture, lamp, and ballast information. 3. For proposed Watts/Fixture, use manufacturer's listed maximum input wattage of the fixture (not simply the lamp wattage) and other criteria as specified in Section C405.5.1. For line voltage track lighting, list the greater of actual luminaire wattage or length of track multiplied by 50, or as applicable, the wattage of current limiting devices of the transformer. For low voltage track lighting list the transformer rated wattage. 4. For lighting equipment eligible for exemption per C405.5.1, note exception number and leave Watts/Fixture blank. 5. Document existing to remain fixtures in Proposed Lighting table in the same manner as new fixtures. Identify as existing in fixture description 6. If #NA appears in Retail Display cells, information on LTG -INT -DISPLAY is incomplete. IInterior Lighting Power Allowance COMPLIES 2012 Washington State Energy Code Compliance Forms for Commercial Buildings including R2 & R3 over 3 stories and all R1 Revised Jan 2014 Projectlnfo Project Address Best Buy -#447 Watts/ Fixture Date 5/21/2013 Retail 17364 South Center Parkway 26 For Building Department Use Tukwila, WA 98188 Applicant Name: Jay Rohkohl Maximum Allowed Display Lighting Wattage Location (plan #, room #) Retail Display Area Type" Allowed Watts per ft2" Gross Interior Watts Allowed Area in fe (watts/fe x area) Retail 1: All unclassified retail display 0.60 3456 2074 Only retail sales areas that meet the requirements defined in Table C405.5.2(2) footnote A may be entered here. Select retail sales areas form drop down menu. " Wattages per Table C405.5.2(2) footnote A. ++ Display light allowance per footnote A calculation. DISPLAY WATTAGE ALLOWED - AS CALCULATED BY AREA Area Area Watts Total 3456 2074 Display Lighting Base Allowance 500 ++ Total Display Allowance 2574 Proposed Display Lighting Wattage Only separately controlled display fixtures independent of general area lighting per Table C405.5.2(2) footnote A may be entered here Location (plan #, Display Area' room #) Fixture Description Number of Fixtures Watts/ Fixture Watts Proposed Retail 108 26 2808 Select retail sales display area from drop down menu. Proposed Display Lighting Totals Total Proposed Wattsj 2808 Retail Retail Retail Retail 2808 Notes: 1. For proposed Display Fixture Description, indicate fixture type, lamp type (e.g. T-8), number of lamps in the fixture, and ballast type (if included). For track lighting, list the length of the track (in feet) in addition to the fixture, lamp, and ballast information. 2. For proposed Watts/Fixture, use manufacturer's listed maximum input wattage of the fixture (not simply the lamp wattage) and other criteria as specified in Section C405.5.1. For line voltage track lighting, list the greater of actual luminaire wattage or length of track multiplied by 50, or as applicable, the wattage of current limiting devices or of the transformer. For low voltage track lighting list the transformer rated wattage. 3. List all display fixtures. Lighting, Motor, and-lWsformer Permit DocumerViChecklist LTG -CHK 2012 Washington State Energy Code Compliance Forms for Commercial Buildings including R2 & R3 over 3 stories and all R1 Revised Jan 2014 Project Address Best Buy -#447 Date 5/21/2013 The following information is necessary to check a permit application for compliance with the lighting, motor, and transformer requirements in the Washington State Energy Code, Commercial Provisions. Applicability Location in Building Department (yes,no,na) Code Section Component Compliance information required in permit documents Documents Notes LIGHTING CONTROLS (Section C405.2) C405.2.1.1 Manual interior Indicate on plans the manual control type & locations served; Indicate of plans the 50% lighting load reduction method NA C405.2.1.2 lighting controls provided or identify exception taken Indicate lighting system automatic shut-off capability - identify lighting zone areas served on plans; Automatic time Indicate locations of override switches on plans and the areas NA C405.2.2.1 switch controls and override switching served, include area sq. ft.; Indicate locations where automatic shutoff is provided by other methods (occupancy sensor, daylight controls, etc) NA C405.2.2.2 Occupancy sensors Indicate on plans the locations served by occupancy sensors Daylight zones - Indicate vertical fenestration primary and secondary daylight NA C405.2.2.3 Vertical fenestration zone areas on plans, include sq. ft.; and skylights Indicate skylight daylight zone areas on plans, include sq. ft. Daylight zone Indicate on plans the locations served by daylight zone controls; NA C405.2.2.3.2 controls Indicate in plans the lighting load reduction (dimming) method - stepped or continuous dimming NA C405.2.3 Specific application lighting controls - Indicate on plans the locations served by specific application General lighting controls Indicate lighting control method for display and accent lighting, and display case lighting; NA C405.2.3 - Display and accent Items 1&2 lighting Indicate these fixtures are controlled independently from both general area lighting and other lighting applications within the same space C405.2.3 - Hotel/motel guest Provide a lighting control device at each guest room entry for all NA Item 3 permanently installed fixtures in guest room; rooms Indicated whether lighting control is manual or automatic NA C405.2.3 - Supplemental task Provide automatic shut-off vacancy controls for supplemental Item 4 lighting task lighting, including under -shelf or under -cabinet lighting Identify eligible non -visual applications and method of lighting C405.2.3 - Lighting for non control;- Indicate these fixtures are controlled independently from both _ NA Item 5 visual applications general area lighting and other lighting applications within the same space Indicate lighting control method for lighting equipment for sale C405.2.3 - Lighting equipment or demonstration; Indicate these fixtures are controlled independentl y from both NA Item 6 for sale or demonstration general area lighting and other lighting applications within the same space If egress lighting power density is greater than 0.05W /ftz, C405.2.3 - Means of egress indicate method of automatic shut-off during unoccupied NA Item 7 lighting periods; Identify on plans the egress fixtures that function as both normal and emergency means of egress illumination C405.10 Cooler and freezer Provide vacancy device or timer to turn off fixtures within 15 NA C405.11 lighting minutes of unoccupancy for cooler and freezer lighting fixtures with lamp efficacy less than 40 I umens per watt NA C405.2.4 Exterior lighting Indicate on exterior lighting plans the automatic lighting control controls method and locations served Exterior building Provide motion sensor controls for building grounds fixtures NA C405.6.1 grounds lighting rated at greater than 100 w atts with lamp efficacy less than 60 controls lumens, or identify exception taken Identify applicable commissioning documentation requirements per Section C408 or el igibility for exception; Provide written procedures for functional testing of all automatic NA C408.3 Lighting system functional testing controls and describe the expected system response; Identify in construction documents the party responsible for functional testing of automatic lighting controls INTERIOR LIGHTING POWER & EFFICACY Sections C405.5, C405.10, C405.11 IN 2012 Washington State Energy Code Compliance Forms for Commercial Buildings including R2 & R3 over 3 stories and all R1 Revised Jan 2014 Project Address Best Buy -#447 Date 5/21/2013 The following information is necessary to check a permit application for compliance with the lighting, motor, and transformer requirements in the Washington State Energy Code, Commercial Provisions. Applicability ILocation in Building Department (yes,no, na) I Code Section Component Compliance information required in permit documents Documents Notes LIGHTING CONTROLS (Section C405.2) C405.2.1.1 Manual interior Indicate on plans the manual control type & locations served; Indicate of plans the 50% lighting load reduction method NA C405.2.1.2 lighting controls provided or identify exception taken Indicate lighting system automatic shut-off capability - identify lighting zone areas served on plans; Automatic time Indicate locations of override switches on plans and the areas NA C405.2.2.1 switch controls and override switching served, include area sq. ft.; Indicate locations where automatic shutoff is provided by other methods (occupancy sensor, daylight controls, etc) NA C405.2.2.2 Occupancy sensors Indicate on plans the locations served by occupancy sensors Daylight zones - Indicate vertical fenestration primary and secondary daylight NA C405.2.2.3 Vertical fenestration zone areas on plans, include sq. ft.; and skylights Indicate skylight daylight zone areas on plans, include sq. ft. Daylight zone Indicate on plans the locations served by daylight zone controls; NA C405.2.2.3.2 controls Indicate in plans the lighting load reduction (dimming) method - stepped or continuous dimming NA C405.2.3 Specific application lighting controls - Indicate on plans the locations served by specific application General lighting controls Indicate lighting control method for display and accent lighting, C405.2.3 - Display and accent and display case lighting; Indicate these fixtures are controlled independently from both NA Items 1&2 lighting general area lighting and other lighting applications within the same space C405.2.3 - Hotel/motel guest Provide a lighting control device at each guest room entry for all NA Item 3 rooms permanently installed fixtures in guest room; Indicated whether lighting control is manual or automatic NA C405.2.3 - Supplemental task Provide automatic shut-off vacancy controls for supplemental Item 4 lighting task lighting, including under -shelf or under -cabinet lighting Identify eligible non -visual applications and method of lighting C405.2.3 - Lighting for non - control; Indicate these fixtures are controlled independently from both NA Item 5 visual applications general area lighting and other lighting applications within the same space Indicate lighting control method for lighting equipment for sale C405.2.3 - Lighting equipment or demonstration; Indicate these fixtures are controlled independently from both NA Item 6 for sale or demonstration general area lighting and other lighting applications within the same space If egress lighting power density is greater than 0.05W /ft2, C405.2.3 - Means of egress indicate method of automatic shut-off during unoccupied NA Item 7 lighting periods; Identify on plans the egress fixtures that function as both normal and emergency means of egress illumination C405.10 Cooler and freezer Provide vacancy device or timer to turn off fixtures within 15 NA C405.11 lighting minutes of unoccupancy for cooler and freezer I ighting fixtures with lamp efficacy less than 40 lumens per watt NA C405.2.4 Exterior lighting Indicate on exterior lighting plans the automatic lighting control controls method and locations served Exterior building Provide motion sensor controls for building grounds fixtures NA C405.6.1 grounds lighting rated at greater than 100 watts with lamp efficacy less than 60 controls lumens, or identify exception taken Identify applicable commissioning documentation requirements per Section C408 or eligibility for exception; Provide written procedures for functional testing of all automatic NA C408.3 Lighting system functional testing controls and describe the expected system response; Identify in construction documents the party responsible for functional testing of automatic lighting controls INTERIOR LIGHTING POWER & EFFICACY Sections C405.5, C405.10, C405.11 PERMIT COORD COPY PLAN REVIEW/ROUTING SLIP PERMIT NUMBER: EL16-0016 DATE: 01/06/16 PROJECT NAME: BEST BUY SITE ADDRESS: 17364 SOUTHCENTER PKWY X Original Plan Submittal Revision # before Permit Issued Response to Correction Letter # Revision # after Permit Issued DEPARTMENTS: 1; R?? 11 Building Division Fire Prevention ❑ Planning Division ❑ Public Works ❑ Structural ❑ Permit Coordinator PRELIMINARY REVIEW: DATE: 01/07/16 Not Applicable ❑ Structural Review Required ❑ (no approval/review required) REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: DUE DATE: 02/04/16 Approved ❑ Approved with Conditions ❑ Corrections Required ❑ Denied ❑ (corrections entered in Reviews) (ie: Zoning Issues) REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: 12/18/2013 ABACUS ELECTRIC CO Home Espanol Contact Safety & Health A Washington State Department of 4j Labor & Industries ABACUS ELECTRIC CO Page I of 3 Search L&I »� A-Z..Index Help My 1A -I Claims & Insurance Workplace Rights Trades & Licensing Owner or tradesperson PO Box 1030 MILTON, WA 98354 Principals 253-984-1611 MOSS, HAYWOOD PIERCE County TROY,PARTNER/MEMBER SMITH, SHANE, PARTNER/MEMBER Doing business as ABACUS ELECTRIC CO WA UBI No. Business type 602 838 703 Limited Liability Company Parent company Governing persons ABACO CONTRACTORS LLC HAYWOOD Electrical Administrator TROY Bond ................. MOSS Lexon Ins Co SHANE TODD SMITH; License Verify the contractor's active registration / license / certification (depending on trade) and any past violations. Electrical Contractor .............................................................. Active. Effective date Meets current requirements. License specialties GENERAL License no. ABACUEC928LT Effective — expiration 06130/2008— 06/30/2016 Designated administrator Active. Yourglich, Matthew R Meets current requirements. License type License no. Electrical Administrator YOURGMR863BH Bond ................. Lexon Ins Co $4,000.00 Bond account no. 9807640 Received by L&I Effective date 06/01/2011 06/27/2011 Expiration date Until Canceled Bond history Savings _............ _....... No savings accounts during the previous 6 year period. License Violations Infraction no. EROJE00473 Satisfied .......................... https:Hsecure.Ini.wa.gov/verify/Detail.aspx?UBI=602838703&LIC=ABACUEC928LT&SAW= 4/20/2016 0 O ■ 0 I— z ¢ z w z LU U 0 60 0 0 ELECTRICAL LIGHTING PLAN 3132" =1'-0" (TYPICAL) GENERALNOTES 1. DEVICES, JUNCTION BOXES SHALL BE RECESSED AND CONDUITS AND WIRES CONCEALED UNLESS OTHERWISE APPROVED BY BEST BUY. NO EXCEPTIONS. 2. CONDUITS, RACEWAYS, ELECTRICAL DUCTS & BOXES AND EXPOSED LOW VOLTAGE WIRE SHALL BE RUN TRUE, PLUMB, SQUARE TO THE BUILDING TIGHTLY WRAPPED OR FASTENED TO STRUCTURE. LOW VOLTAGE RUNS OR EXPOSED WIRE MUST BE HIDDEN FROM VIEW AND TIE WRAPPED TO THE STRUCTURE WITH WHITE WRAPS. TIE WRAPS MUST BE UNIFORMLY SPACED WITH ENOUGH WRAPS TO PREVENT WIRE FROM SAGGING. UNDER NO CIRCUMSTANCES CAN EXPOSED WIRE BE RUN IN FREE AIR OR DIAGONALLY. 13. ELECTRICAL BOXES ON OPPOSITE SIDES OF FIRE RATED WALL SHALL BE SEPARATED BY A MINIMUM OF 24". 4. USE PLENUM RATED CABLE, CONDUIT, BOXES, ETC. IN AIR PLENUM WALLS AND CEILINGS. ALL PENETRATIONS IN FIRE RATED WALLS ARE TO BE COMPLETELY FIRE SEALED. 15. RUN ELECTRICAL EQUIPMENT, CONDUIT AND WIRING ABOVE BOTTOM OF JOISTS AND AS TIGHT TO THE DECK AS POSSIBLE, COORDINATE THIS WORK WITH OTHER TRADES BEFORE PROCEEDING. 6. THE ELECTRICAL CONTRACTOR SHALL VERIFY VOLTAGE RATINGS OF NEW OR RELOCATED LIGHTS, SIGNS, COMPACTORS, RTU'S, EXHAUST FANS, MOTORS, ETC. TO AVOID ANY DAMAGE TO EQUIPMENT WHEN ENERGIZED. IT WILL BE THE SOLE RESPONSIBILITY OF THE ELECTRICAL CONTRACTOR TO REPAIR OR REPLACE ANY EQUIPMENT DAMAGED BY BEING CONNECTED TO THE WRONG VOLTAGE AT NO COST TO BEST BUY. 7. BRANCH CIRCUIT CONDUCTORS SHALL BE IDENTIFIED AT JUNCTIONS, DEVICES, SPLICES AND TERMINATIONS. WHEN A NEUTRAL CONDUCTOR IS REQUIRED, THE NEUTRAL CONDUCTOR SHALL BE IDENTIFIED WITH CORRESPONDING PHASE CONDUCTOR WHICH FORMS THE BRANCH CIRCUIT. S. HOMERUNS SHALL BE 112" MINIMUM CONDUIT SIZE UNLESS OTHERWISE NOTED. 9. REFER TO SHEET E4.0 ELECTRICAL DETAILS FOR ADDITIONAL INFORMATION. 10. ALL MODULAR FLEX WIRING AND CONNECTIONS TO FACE THE BACK OF THE STORE. NO EXCEPTIONS. 11. LIGHT FIXTURES SHALL BE INSTALLED BY THE ELECTRICAL CONTRACTOR. 12. DO NOT SCALE FROM THIS PLAN. COORDINATE DIMENSIONS WITH ARCHITECTURAL PLANS. 13. HORN/STROBES, EXIT LIGHTS, EMERGENCY LIGHTS, ELECTRICAL BOXES FOR SIGNS ETC. SHALL NOT BE INSTALLED IN WALL GRAPHICS, BUT DIRECTLY BELOW GRAPHICS ON WALL. COORDINATE WITH INTERIOR ELEVATIONS ON THE GRAPHICS, ARCHITECTURAL SHEETS AND FIXTURE PLANS. NO EXCEPTIONS. 14. ADDITIONAL EMERGENCY BATTERY LIGHTING HEADS, EMERGENCY BATTERY EXITS, OR ADJUSTMENTS THAT ARE REQUIRED BY THE AUTHORITY HAVING JURISDICTION FOR THIS BUILDING WILL BE PROVIDED BY THE ELECTRICAL CONTRACTOR. 15. GENERAL CONTRACTOR TO PROVIDE FIRE-RESISTANT ENCLOSURE FOR RECESSED LIGHT FIXTURES IN FIRE RATED CORRIDORS. SEE ARCHITECTURAL DETAILS. 16. LAY -IN FIXTURES USED ON SUSPENDED CEILINGS SHALL BE SUPPORTED INDEPENDENTLY OF THE CEILING GRID, BUT SHALL NOT EXEMPT SECURING OF FIXTURES TO CEILING GRID PER NEC. 17. WHERE UNGROUNDED CONDUCTORS ARE INCREASED IN SIZE, EQUIPMENT GROUND CONDUCTORS, WHERE INSTALLED, SHALL BE INCREASED IN SIZE PROPORTIONATE TO CIRCULAR MIL. AREA OF THE UNGROUNDED CONDUCTORS. 18. PROVIDE UNSWITCHED CONDUCTOR TO EMERGENCY AND EGRESS LIGHT FIXTURES. 19. PROVIDE HANDLE TIE AT BREAKER FOR SHARED NEUTRAL CIRCUITS. KEYED NOTES: ALL LIGHTING IN HATCHED AREA IS EXISTING TO REMAIN UNLESS NOTED OTHERWISE. MAINTAIN EXISTING CONNECTIONS AND CONTROLS. O EMERGENCY/EXIT LIGHTING IS EXISTING TO REMAIN UNLESS NOTED OTHERWISE. MAINTAIN EXISTING CONNECTIONS. CONTRACTOR TO TEST FUNCTIONALITY OF EXISTING EMERGENCY LIGHTING. PROVIDE UNIT PRICING TO REPLACE DAMAGED OR DEFECTIVE UNITS. 3O COORDINATE EXACT LIGHT FIXTURE LOCATION PRIOR TO ROUGH -IN WITH EXISTING CEILING CONDITIONS TO AVOID ANY WIRING AND MOUNTING CONFLICTS, 40 EXTEND MODULAR WIRING CONNECTION TO EXISTING HIGH BAY LIGHTING FIXTURE CIRCUIT AND CONTROLS NEARBY. DO NOT LOAD LIGHTING CIRCUIT MORE THAN 80% RATED AMPERAGE PER BREAKER SIZE. OLINE TYPE INDICATES MODULAR WIRING SYSTEM. EC TO MATCH EXISTING MODULAR WIRING SYSTEM AS SHOWN FOR NEW 2X4 HIGH BAY LIGHTING FIXTURES OR PROVIDE STANDARD WIRING AS REQUIRED. 0 EC TO MATCH EXISTING LIGHTING LAYOUT. MAINTAIN EXISTING DISTANCE BETWEEN ROWS AND COLUMNS. PROVIDE NEW LIGHT FIXTURES AS REQUIRED. OEC TO RELOCATE OR PROVIDE NEW EMERGENCY LIGHTING TO ACCOMMODATE THIS AREA AS REQUIRED. EXTEND AND RECONNECT CIRCUITRY TO NEAREST EMERGENCY LIGHT IN SALES FLOOR AREA. OPROVIDE UNSWITCHED CIRCUITS TO EMERGENCY BALLAST FIXTURES. PROVIDE UNSWITCHED CIRCUIT FOR EMERGENCY BATTERY PACKS AND EXIT LIGHTS. 0 REUSE EXISTING VALANCE LIGHTING AND RECONNECT TO EXISTING VALANCE LIGHTING CIRCUIT. NOTE TO ELECTRICAL CONTRACTOR ALL LIGHTING TO BE PURCHASED THROUGH VILLA LIGHTING UNLESS NOTED OTHERWISE. NO EXCEPTIONS. VILLA LIGHTING 1-800-325.0963 WHIP LENGTH AND TYPE IS LEFT UNSPECIFIED. CONTRACTOR IS RESPONSIBLE FOR ORDERING PROPER WHIP LENGTH AND ,g;,7fE BASED ON SITE SPECIFIC CONDITIONS. PRIOR TO ORDERING FIXTURES COORDINATE EXISTING MODULAR WIRING TYPE WITH MIKE MEDEIROS @ ACS (MODULAR SYSTEM MANUFACTURER) TO ASSURE PROPER WHIPS ARE ORDERED FOR EXISTING SYSTEM. PROVIDE ADDITIONAL MODULAR COMPONENTS AS REQUIRED FOR A COMPLETE INSTALLATION. MIKE MEDEIROS_-($.ZZY242-6668 ;Plan review asaprov lis suiajodt to errors and orr, o Approval of consiruction documents does nbt ult hoilza the violation of r~ rly adopted code or ordinance. fiecoIPt of approved .t=iold Copy and coed dull s Is �ackncm;iedged: Date: City Of_111 CMI'd BUILDING DIVISION i REVISIONS No changes sh 'I k -n r",^d^ to the scope Of b°Tar:C LlritiiC: :; pr" -or approvd of R".. ,ding Division. F -3,-`s?: .. v4`1 r3quirc, c iic-.3 plan submittal arcl may inz.'ud$ additional pian rev' ew fees. 1 '[ 11'� �..d ty V �• Ela:,irlcat Plumbing C --!7s Pring '; Ci T luk< -,A!a C'NiSION F—zRi W 08Gc,'G E Note: Not all fixture types ZN'*MrM O rn La J N n t � n v U) . Oct z Q my O 2! E ZZ o WMC-4v- 0 Y a CL .v 0 � to V O O J =�.4 0=a .. i2 LAJ 'w Il– N W .. _J U3ZZ a _� cc aX•• �o?2a 1 H ao � It u W Ix 1041(5 SQ. FT. CALCS RETAIL: 38,966 SF OFFICES & ASSEMBLY: 876 SF STORAGE/ 41890 S F REMAINING: INSTALL: 11153 SF TOTAL: 45,885 SF REMODEL AREA: 61767 SF CONCEPT: 45K CS1.9 CONCEPT DATE: XX XXXX G.O. -21 FIXTURE REL. XXXXXX G.O.-13 FINAL REL. ��/��// M.M.M PROTOTYPE DATE: XXXXxx STORE NUMBER: 0447 Note: Not all fixture types may be used on plan. rn SYMBOL VA TAG TYPE VOLTAGE r LAMP BALLAST MANUFACTURER'S CATALOG # a3 NOTES y.: aD �►n C LINEAR FLUORESCENT HIGH BAY. ELECTRICAL Q ion c CONTRACTOR TO PROVIDE SUSPENSION CABLES AND • 187 C BAY 277 LO tx (1) 6 -LAMP BALLAST, 1.15 BF LITHONIA:IBZ-632-WD-277 LAMP GUARDS. C� EMERGENCY BATTERY Ld O r N C SURFACE (2) 20W-12 VOLT HALOGEN N O U 12 X2 LAMP HEADS 277 C= LAMPS INCLUDED LL LITHONIA: #ELM1272-H2O12-SD WITH SELF DIAGNOSTICS. 1,2,3 LO co U 1 SUBSTITUTION OF LAMPS FOR THE LIGHTING PACKAGE MUST BE MADE IN ACCORDANCE WITH THE LEED MERCURY CREDITAND CUT SHEETS, PROVING COMPLIANCE SHALL BE SENTTO THE ENGINEER FOR REVIEW RECEIVED BEFORE PURCHASING. csTv ®F TUKWiLA R N N O V Lo U i;y m 1 O U) S � + N C 2 - cD E Q E O N C -:5°- cc -'o s c 0 E_ O o iV D Lo '2 it 3 E_ JOB #: 416752-040 SQ. FT. CALCS RETAIL: 38,966 SF OFFICES & ASSEMBLY: 876 SF STORAGE/ 41890 S F REMAINING: INSTALL: 11153 SF TOTAL: 45,885 SF REMODEL AREA: 61767 SF CONCEPT: 45K CS1.9 CONCEPT DATE: XX XXXX G.O. -21 FIXTURE REL. XXXXXX G.O.-13 FINAL REL. ��/��// M.M.M PROTOTYPE DATE: XXXXxx STORE NUMBER: 0447 REVIEWED .FOR _— M COMPLIANCE WITH ~ SEC �^ BID & PERMIT SET 12-04-15 Irl marl VISIC) 1 LIGHTING SCHEDULE Note: Not all fixture types may be used on plan. SYMBOL VA TAG TYPE VOLTAGE r LAMP BALLAST MANUFACTURER'S CATALOG # REMARKS NOTES y.: �►n LINEAR FLUORESCENT HIGH BAY. ELECTRICAL Q ion CONTRACTOR TO PROVIDE SUSPENSION CABLES AND • 187 C BAY 277 AIRCRAFT CABLE (6) GE #F28T8/XL/SPX50/ECO (1) 6 -LAMP BALLAST, 1.15 BF LITHONIA:IBZ-632-WD-277 LAMP GUARDS. REVIEWED .FOR _— M COMPLIANCE WITH ~ SEC �^ BID & PERMIT SET 12-04-15 Irl marl VISIC) 1 LIGHTING SCHEDULE Note: Not all fixture types may be used on plan. SYMBOL VA TAG TYPE VOLTAGE MOUNTING LAMP BALLAST MANUFACTURER'S CATALOG # REMARKS NOTES LINEAR FLUORESCENT HIGH BAY. ELECTRICAL Q FLUORESCENT HIGH CONTRACTOR TO PROVIDE SUSPENSION CABLES AND 187 C BAY 277 AIRCRAFT CABLE (6) GE #F28T8/XL/SPX50/ECO (1) 6 -LAMP BALLAST, 1.15 BF LITHONIA:IBZ-632-WD-277 LAMP GUARDS. 1,2,3 EMERGENCY BATTERY UNIT WITH TUNGSTEN SURFACE (2) 20W-12 VOLT HALOGEN WHITE COLOR HOUSING STANDARD. UNIT PROVIDED 12 X2 LAMP HEADS 277 (UNIVERSAL) LAMPS INCLUDED LITHONIA: #ELM1272-H2O12-SD WITH SELF DIAGNOSTICS. 1,2,3 GENERAL NOTES 1 SUBSTITUTION OF LAMPS FOR THE LIGHTING PACKAGE MUST BE MADE IN ACCORDANCE WITH THE LEED MERCURY CREDITAND CUT SHEETS, PROVING COMPLIANCE SHALL BE SENTTO THE ENGINEER FOR REVIEW RECEIVED BEFORE PURCHASING. csTv ®F TUKWiLA 2 MATCH EXISTING MOUNTING HEIGHTS JAN 0 6 2016 KEY NOTES 1 NO SUBSTITUTION OF LIGHT FIXTURES SHALL BE ALLOWED. NO EXCEPTIONS. PERMIT CENTER 2 ELECTRICAL CONTRACTOR SHALL PROVIDE CONDUIT AND WIRE IF MODULAR FLEX WIRING IS NOTALLOWED BY THE AUTHORITY HAVING JURISDICTION AND INCLUDE IN YOUR BID. 3 THE ELECTRICAL CONTRACTOR SHALL FURNISH LIGHT FIXTURES, LAMPS AND MISCELLANEOUS HARDWARE, INCLUDING FLEXIBLE MODULAR WIRING SYSTEMS. "A& nA& nA& ELECTRICAL LIGHTING PLAN E0.1 G) U2 � 3 (41 (5� O 0 0 0 _ n p f S 2'-2" 6 E4.0 ! @18 @75" J 105.5" F 10Kyj I r 1 CKT 1 CKT M Im— EXIST. PANEL LF EXIST. PANEL LG D No __ I wjpmm .6 5 1 �2 3W/ W6 W5 1 tW2 VytJ Wi1 VJl1 W!3 _ 3 6� 5 — 2 3 — —1— F 6 CKT 6 CKTS �13" E4.0 r� 1 CKT 1 CKl 1 CKT 4 CKTS I 4 (TYPICAL) 2 s1 CKT K1 1 CKT { 3 (TYPICAL) � I I1 CKT 1 6 Cq12 I � , CKT I I 12 PANEL LH\ \ L�� `� `� — — — — a O ---- 0 ELECTRICAL POWER PLAN 3132" =1'-0" Im- Ca 2'-2" 2'-2" CIRCUIT QUANTITIES SALES FLOOR CIRCUITS ARE EXISTING IN CEILING. EC TO FIELD VERIFY EXACT CIRCUIT LOCATIONS IN CEILING AND REDISTRIBUTE AS SHOWN UNLESS NOTED OTHERWISE. DEMOLITION NOTE CONTRACTOR TO MAXIMIZE RE -USE OF ALL EXISTING CIRCUITS. MAINTAIN EXISTING CIRCUITS WHEREVER POSSIBLE AND REDISTRIBUTE AS SHOWN ON DRAWINGS. LABEL ANY UNUSED CIRCUITS FOR FUTURE USE AND MARK LOCATION ON ASBUILT DRAWINGS. NOTE TO CONTRACTOR CONTRACTOR TO RE -USE EXISTING FIXTURE LEVEL AMPINNERGY FLEXIBLE WIRING SYSTEM. TURN OVER ANY UNUSED AMPINNERGY PRODUCTS TO BEST BUY. MAXIMUM OF 10 DUPLEXES OR EQUIVALENT ALLOWED ON A CIRCUIT. 0 EXIST. PANEL LD EXIST. PANEL LB 1 > (TYPICAL) PANEL LE GENERALNOTES 1. DEVICES AND JUNCTION BOXES SHALL BE RECESSED AND CONDUITS AND WIRES CONCEALED UNLESS OTHERWISE APPROVED BY BEST BUY. NO EXCEPTIONS. 2 CONDUITS, RACEWAYS, ELECTRICAL DUCTS & BOXES AND EXPOSED LOW VOLTAGE WIRE SHALL BE RUN TRUE, PLUMB AND SQUARE TO THE BUILDING AND TIGHTLY WRAPPED OR FASTENED TO STRUCTURE. LOW VOLTAGE RUNS OR EXPOSED WIRE MUST BE HIDDEN FROM VIEW AND TIE WRAPPED TO THE STRUCTURE WITH WHITE WRAPS. TIE WRAPS MUST BE UNIFORMLY SPACED WITH ENOUGH WRAPS TO PREVENT WIRE FROM SAGGING. UNDER NO CIRCUMSTANCES CAN EXPOSED WIRE BE RUN IN FREE AIR OR DIAGONALLY. 3. ELECTRICAL BOXES ON OPPOSITE SIDES OF FIRE RATED WALL SHALL BE SEPARATED BY A MINIMUM OF 24". 4. USE PLENUM RATED CABLE, CONDUIT, BOXES, ETC. IN AIR PLENUM WALLS AND CEILINGS. ALL PENETRATIONS OF FIRE RATED WALLS ARE TO BE COMPLETELY FIRE SEALED. 5. RUN ELECTRICAL EQUIPMENT, CONDUIT AND WIRING ABOVE BOTTOM OF JOISTS AND AS TIGHT TO THE DECK AS POSSIBLE, COORDINATE THIS WORK WITH OTHER TRADES BEFORE PROCEEDING. 6. THE ELECTRICAL CONTRACTOR SHALL VERIFY VOLTAGE RATINGS OF NEW OR RELOCATED LIGHTS, SIGNS, COMPACTORS, RTU'S, EXHAUST FANS, MOTORS, ETC. TO AVOID ANY DAMAGE TO EQUIPMENT WHEN ENERGIZED. IT WILL BE THE SOLE RESPONSIBILITY OF THE ELECTRICAL CONTRACTOR TO REPAIR OR REPLACE ANY EQUIPMENT DAMAGED BY BEING CONNECTED TO THE WRONG VOLTAGE AT NO COST TO BEST BUY. 7. BRANCH CIRCUIT CONDUCTORS SHALL BE IDENTIFIED AT JUNCTIONS, DEVICES, SPLICES AND TERMINATIONS. WHEN A NEUTRAL CONDUCTOR IS REQUIRED, THE NEUTRAL CONDUCTOR SHALL BE IDENTIFIED WITH CORRESPONDING PHASE CONDUCTOR WHICH FORMS THE BRANCH CIRCUIT. 8. HOMERUNS SHALL BE 112" MINIMUM CONDUIT SIZE UNLESS OTHERWISE NOTED. 9. ISOLATED GROUND CIRCUIT MUST HAVE A SEPARATE GROUNDING WIRE AS A DEDICATED GROUND (NOT NEUTRAL). ALL GROUND WIRES SHALL BE CONNECTED TO A COMMON ISOLATED GROUND BUS AT THE PANELBOARD. 10. SEE E4, FOR ADDITIONAL CONDUIT REQUIREMENTS FOR BEST BUY. 11. OUTLET HEIGHTS WILL BE TO CENTER OF OUTLET, UNLESS OTHERWISE NOTED. 12. DO NOT SCALE FROM THIS PLAN. 13. COORDINATE ALL CONDUIT AND BOX INSTALLATIONS ON COLUMNS WITH GENERAL CONTRACTOR BEFORE ROUGH -IN. 14. ALL RECEPTACLES SHALL BE 20 AMP, UNLESS OTHERWISE NOTED. 15. DOORS TO ELECTRICAL ROOMS SHALL BE SIGNED AS SUCH "ELECTRICAL ROOM" ELECTRICAL CONTRACTOR TO PROVIDE ENGRAVED BLACK NAME PLATE WITH WHITE LETTERS. NO EXCEPTIONS. 16. IF PVC UNDERGROUND CONDUIT IS NOTALLOWED BY AUTHORITY HAVING JURISDICTION PROVIDE RIGID GALVANIZED STEEL CONDUIT AND GROUND AS REQUIRED. 17. WHERE UNGROUNDED CONDUCTORS ARE INCREASED IN SIZE, EQUIPMENT GROUND CONDUCTORS, WHERE INSTALLED, SHALL BE INCREASED IN SIZE PROPORTIONATELY ACCORDING TO CIRCULAR MIL. AREA OF THE UNGROUNDED CONDUCTORS. 18. ALL CONDUITS SHALL BE A MINIMUM OF 3" BELOW THE SLAB WITH GROUND COVER. 19. PROVIDE BRUSHED STAINLESS STEEL WALL COVER PLATES. 20. CONTRACTOR TO ACCOUNT FOR VOLTAGE DROP WHEN PROVIDING NEW OR REUSING EXISTING BRANCH CIRCUITING. VOLTAGE DROP TO BE BASED ON LOADS SHOWN IN PANEL SCHEDULES. 21. CONTRACTOR TO VERIFY CIRCUITS ARE UNSWITCHED VIA EMS PRIOR TO RE -USE FOR GONDOLA POWER, ONLY UNSWITCHED CIRCUITS MAY BE RE -USED FOR GONDOLA POWER. 22. EXISTING FLOOR BOXES IN PAC SALES, MAGNOLIA DESIGN CENTERS, AND VENDOR PADS TO BE REMOVED AND FILLED IN. ANY FLOOR BOXES WHERE POWER IS INTERRUPTED BY REMOVAL OF BOXES IN AFOREMENTIONED AREAS SHALL ALSO BE REMOVED AND FILLED IN. TURN OVER ANY SALVAGEABLE FLOOR BOX COMPONENTS TO BEST BUY FOR RE -USE ON DAMAGED FLOOR BOXES THAT ARE EXISTING TO REMAIN. KEYED NOTES OELECTRICAL IN HATCHED AREA IS EXISTING TO REMAIN. MAINTAIN EXISTING CONNECTIONS UNLESS OTHERWISE NOTED. O2 SURFACE MOUNTED 1" CONDUIT WITH MC CABLE RUN FROM JOIST SPACE DOWN WALL TO JUNCTION BOX MOUNTED ON WALL ABOVE FIXTURE. SEE DETAIL 1/E4,0. O3 EXISTING SALES FLOOR GONDOLAS BEING REARRANGED IN NOTED AREAS. RE -USE EXISTING FIXTURE LEVEL DEVICES AND RECONNECT TO OVERHEAD FEED AT NEW LOCATION. RE -DISTRIBUTE NEARBY EXISTING OVERHEAD CIRCUITS AND EXTEND TO NEW LOCATION AS REQUIRED. MAINTAIN ACCURATE AS BUILT DRAWINGS. 4O FIXTURE EXTENSION FROM JOIST SPACE DOWN TO DISPLAY FIXTURE WITH PULL LINE. SEE DETAIL 4/E4.0. BEST BUY SPECIFIED FIXTURE EXTENSION SHALL BE FURNISHED AND INSTALLED BY OTHERS. BOND FIXTURE EXTENSION TO BUILDING STEEL. REUSE EXISTING PERIMETER POWER CIRCUITS AND DEVICES UNLESS NOTED OTHERWISE. OPANELS ARE EXISTING AND SHOWN FOR REFERENCE ONLY. 7O EC TO FIELD VERIFY (3) EMPTY SURFACE MOUNTED 4" CONTINUOUS CONDUIT WITH PULL LINES FROM COMM. EXIST. IF (3) 4" CONDUITS DON'T EXIST, PROVIDE NUMBER OF CONUDITS AS REQUIRED FOR A TOTAL OF (3) 4" CONDUITS. ROOM WALL AT 8'-0" A.F.F. TO JOIST SPACE USING 3'-0"+- RADIUS SWEEPS TO MAKE THE BENDS, AND WITH NYLON BUSHINGS AT EACH END. CONDUIT TO PENETRATE SALES FLOOR WALL IN JOIST SPACE. VERIFY EXACT LOCATION IN FIELD. 8O MOUNTED IN BASE DECK OF FIXTURE AS REQUIRED. ODUPLEX GFI RECEPTACLE (GRAY). MOUNTED 20" A.F.F. TO CENTER UNLESS OTHERWISE NOTED. <8>SURFACE MOUNT (1)1"CONDUIT FROM 8'-2" AFF, UNLESS OTHERWISE NOTED, TO JOIST SPACE, WITH A 90 DEGREE RADIUS BEND (AT JOIST), AND NYLON BUSHINGS ON EACH END. <8>OUTER AUTO DOORS BEING REPLACED. DISCONNECT AND RECONNECT. PROVIDE NEW CONNECTIONS AS REQUIRED. <8>EXISTING TV WALL IS BEING REWORKED IN THIS AREA SHOWN. REUSE EXISTING ELECTRICAL DEVICES AS NECESSARY. EXTEND AND RECONNECT TO TO EXISTING CIRCUITING AS REQUIRED. SEE DETAIL 6/E4.0. SYMBOL DESIGNATION MTG HT SWITCHES & CONTROLS ELECTRICAL ABBREVIATIONS SINGLE POLE TOGGLE SWITCH 48" Z DOUBLE POLE TOGGLE SWITCH 48" 3 THREE WAY TOGGLE SWITCH 48" it..co BOJ = FOUR WAY TOGGLE SWITCH 48" .�v =E TOGGLE SWITCH -"a" INDICATES SWITCHING 48" -0 DIMMER SWITCH (# = WATTAGE) 48" -00 OCCUPANCY SENSOR - WALUCLGMOUNT 12"BFC OCCUPANCY SENSOR WALL SWITCH 48" rc TIME CLOCK 60" CONTACTOR 60" �Q RELAY VERIFY ELECTRIC THERMOSTAT 60" LIGHTING O- # b LIGHT FIXTURE ID - REFER TO LT FIXT SCHEDULE (FIXT SCHEDULE OVERRIDES SYMBOL ABBREVIATION) A - INDICATES LIGHT FIXTURE TYPE # - INDICATES CIRCUIT NUMBER b - INDICATES SWITCHING ® 0 LIGHT FIXTURE CIRCUIT TYPE . NO HATCH INDICATES NORMAL CIRCUIT IG TROFFER TYPE LIGHT FIXTURE, SIZE AS INDICATED - CEILING MOUNT 1—$1 CHANNEL OR INDUSTRIAL, LENGTH AS INDICATED 0 DOWNLIGHT CLG FIXT, RECESSED OR SURFACE MNT KVA SMALL WALL MOUNT FIXTURE OR SCONCE VERIFY KW LINEAR WALL MOUNT FIXT, LENGTH AS INDICATED VERIFY 0 UNDER CABINET FIXTURE, LENGTH AS INDICATED REVIEWED.FOR C TRACK FIXTURE, NUMBER OF HEADS AS INDICATED PH EMERGENCY BATTERY LIGHT -WALUCLGMNT VERIFY _® EXIT LIGHT, FILLED QUADRANT INDICATES FACES WALUCEILING MOUNT VERIFY POWER sm BRANCH CIRCUIT PANEL VERIFY am EMERGENCY PANEL VERIFY ® DISTRIBUTION PANEL OR SWITCHBOARD VERIFY © TRANSFORMER VERIFY SPEAKER MOTOR OR MOTOR CONNECTION VERIFY THERMOSTAT DISCONNECT SWITCH VERIFY 490 DUPLEX RECEPTACLE- WALUCEILING MOUNT 20" T QUADPLEX RECEPTACLE -WALL MOUNT 20" ® SPECIAL PURPOSE RECEPTACLE -WALUCLG MNT VERIFY WEATHERPROOF KEY NOTE VERIFY SYMBOL DESIGNATION LLA Zcq,*MM C ELECTRICAL ABBREVIATIONS AFCI ARC FAULT CIRCUIT INTERRUPTER AFF ABOVE FINISHED FLOOR tG p_j SLY AHU AIR HANDLING UNIT it..co BOJ = BBY BEST BUY .�v =E C CONDUIT .. J V3zz Q CKT CIRCUIT mem CU COPPER EC ELECTRICAL CONTRACTOR EM EMERGENCY EMT ELECTRICAL METALLIC TUBING FA FIRE ALARM FACP FIRE ALARM CONTROL PANEL i GFI GROUND FAULT INTERRUPTER GND GROUND IG ISOLATED GROUND JBOX JUNCTION BOX KV KILOVOLT KVA KILOVOLT -AMP KW KILOWATT MC MOMENTARY CONTACT REVIEWED.FOR C AL ELECTRICAL CODE PH PHASE COMPLIANCE WIT PNL PANEL NFPA 70 - NEC RECEIPT RECEPTACLE a REFG REFRIGERATOR RTU ROOF TOP UNIT JAN 13 2016 SW SWITCH SPKR SPEAKER TSTAT THERMOSTAT TYP TYPICAL , CityTTlrkWrila UH T , BUILDING DIVISIO VA VO VOLT -AMP -AMP WP WEATHERPROOF XFMR TRANSFORMER NOTE: REFER TO MOTOR AND EOUIPMENT SCHEDULES FOR ADDITIONAL MOTOR ABBREVIATIONS. RACEWAYS CONDUIT AS DESCRIBED ON DRAWINGS AND SPECIFICATIONS MODULAR WIRING CAT5CABLE 0-10V CONTROL WIRING " 1 UNDERGROUND CONDUITS �y CONDUIT WITH BUSHED END CONDUIT WITH BREAK OR CONTINUATION CIRCUIT HOME RUN �#Ify L1 L1 INDICATES PANEL NUMBERS INDICATE CIRCUITS CONDUCTOR COUNT - UNLESS NOTED OTHERWISE - SHORT HASH INDICATES 1#12 LINE JAN 0 6 LZ ,J LONG HASH INDICATES 1#12 NEUTRAL HASH WI DOT INDICATES 1#12 GROUND 0 JUNCTION BOX- WALUCEILING MOUNT H �PviD Rp 9` �4 \s c/STEa�°�C�``, S/0 M_ vL /o4/FS c d C c L o to o Lo `r p _N C U � � U y m E .. R V N V d N y In 0U E-- + U)i 1A E �o a R p C1 C U c c COcl0 c o m W n Lo 2 R E_ JOB #: 416752-040 SQ. FT. CALCS _ RETAIL: 38,966 SF OFFICES S ASSEMBLY: 876 SF STORAGE/ 890 SF REMAINING: 4 INSTALL: 11153 '153 S F TOTAL: 45,885 SF REMODEL AREA: 61767 SF CONCEPT: 45K CS1.9 CONCEPT DATE: xx.%x.xx G.O.-21��FD(�T//UREE/REL. ��/��// M.M.M G.O.-13XFINAL REL. ��/��// M.M.M PROTOT��Y//PEE//DATTEvE::v ��//��// M.M.M STORE NUMBER: 0447 0 LLA Zcq,*MM C wZ Q ZZ 2i E tG p_j SLY yW2 �® > V it..co BOJ = 3'- �z00. .�v =E 0 ME .. c_> .. J V3zz Q A <.zo -2 mem i_00 1LL.�. W �PviD Rp 9` �4 \s c/STEa�°�C�``, S/0 M_ vL /o4/FS c d C c L o to o Lo `r p _N C U � � U y m E .. R V N V d N y In 0U E-- + U)i 1A E �o a R p C1 C U c c COcl0 c o m W n Lo 2 R E_ JOB #: 416752-040 SQ. FT. CALCS _ RETAIL: 38,966 SF OFFICES S ASSEMBLY: 876 SF STORAGE/ 890 SF REMAINING: 4 INSTALL: 11153 '153 S F TOTAL: 45,885 SF REMODEL AREA: 61767 SF CONCEPT: 45K CS1.9 CONCEPT DATE: xx.%x.xx G.O.-21��FD(�T//UREE/REL. ��/��// M.M.M G.O.-13XFINAL REL. ��/��// M.M.M PROTOT��Y//PEE//DATTEvE::v ��//��// M.M.M STORE NUMBER: 0447 0 BID & PERMIT SET 12-04-15 REV DATE A A'A' A LU ID _ A kwila A IIVISION a i BID & PERMIT SET 12-04-15 REV DATE A A'A' A LU ID _ A kwila A IIVISION a O 3� 4) z z w z w v Q Q .5 1 (6) ELECTRICAL LOW VOLTAGE PLAN 3132" =1'-0" ME GENERAL NOTES 1. DEVICES, JUNCTION BOXES SHALL BE RECESSED AND CONDUITS AND WIRES CONCEALED UNLESS OTHERWISE APPROVED BY BEST BUY. NO EXCEPTIONS. 2. CONDUITS, RACEWAYS, ELECTRICAL DUCTS & BOXES AND EXPOSED LOW VOLTAGE WIRE SHALL BE RUN TRUE, PLUMB, SQUARE TO THE BUILDING TIGHTLY WRAPPED OR FASTENED TO STRUCTURE. LOW VOLTAGE RUNS OR EXPOSED WIRE MUST BE HIDDEN FROM VIEW AND TIE WRAPPED TO THE STRUCTURE WITH WHITE WRAPS. TIE WRAPS MUST BE UNIFORMLY SPACED WITH ENOUGH WRAPS TO PREVENT WIRE FROM SAGGING. UNDER NO CIRCUMSTANCES CAN EXPOSED WIRE BE RUN IN FREE AIR OR DIAGONALLY. 3. ELECTRICAL BOXES ON OPPOSITE SIDES OF FIRE RATED WALL SHALL BE SEPARATED BY A MINIMUM OF 24". 4. USE PLENUM RATED CABLE, CONDUIT, BOXES ETC. IN AIR PLENUM WALLS AND CEILINGS. PENETRATIONS ARE TO BE COMPLETELY FIRE SEALED. 5. RUN LOW VOLTAGE, CONDUIT AND WIRING ABOVE BOTTOM OF JOIST AND AS TIGHT TO DECK AS POSSIBLE. 6. ELECTRICAL CONTRACTOR TO PROVIDE UNDERGROUND CONDUIT FOR LOW -VOLTAGE CABLE, PER EIA-TIA 56BA STANDARDS. 7. ELECTRICAL CONTRACTOR TO PROVIDE EMT DROPS FOR LOW -VOLTAGE AS REQUIRED BY THE AUTHORITY HAVING JURISDICTION. B. FLUSH FLOOR BOXES SHALL HAVE A BRASS COVER PLATE AND BRASS TRIM RING. SEE SPECIFICATIONS. 9. PROVIDE A DOORBELL BUTTON AT THE RECEIVING DOCK DOOR THAT RINGS A BELL AT BOTH THE RECEIVING AREA AND THE CUSTOMER SERVICE AREA. ALSO, PROVIDE A DOORBELL BUTTON AT THE FRONT ENTRANCE DOOR THAT RINGS A BUZZER AT THE CUSTOMER SERVICE AREA. 10. CONDUIT SHALL BE 1 114" WITH PULL LINE UNLESS OTHERWISE NOTED. 11. IF PVC UNDERGROUND CONDUIT IS NOT ALLOWED BY AUTHORITY HAVING JURISDICTION PROVIDE RIGID GALVANIZED STEEL CONDUIT AND GROUND AS REQUIRED. 12. PROVIDE IN THE BID THE COST OF (10) ADDITIONAL CONDUIT DROPS FOR SECURITY DEVICES AND MOTION SENSORS. EACH DROP TO CONSIST OF 314" EMPTY EMT CONDUIT FROM DECK WITH JUNCTION BOX AND BLANK COVER PLATE. COORDINATE WITH SECURITY CONTRACTOR EXACT LOCATIONS AND SPECIFIC REQUIREMENTS PRIOR TO ROUGH -IN. 13. PROVIDE BRUSHED STAINLESS STEEL WALL COVER PLATES. 14. CONDUITS SHALL BE A MINIMUM OF 3" BELOW THE SLAB WITH GROUND COVER. KEYED NOTES REMOTE DOOR ALARM ANNUNCIATOR PROVIDE FLUSH JUNCTION BOX WITH SINGLE GANG MUD RING, 112" CONDUIT, WIRING AND CONNECTIONS TO EXIT DOOR CONTROLLER. ANNUNCIATOR FURNISHED BY DOOR HARDWARE SUPPLIER INSTALLED BY THE ELECTRICAL CONTRACTOR AND WIRED COMPLETE. VERIFY ALL REQUIREMENTS WITH DOOR HARDWARE SUPPLIER AND PROVIDE. SEE DETAIL NE8. FLUSH MOUNTED LOW VOLTAGE DOOR BUTTON MOUNTED AT 48" A.F.F., UNLESS NOTED OTHERWISE. PROVIDE 112" CONDUIT TO BELUBUZZER LOCATIONS. SEE PLAN SHEET E2, POWER PLAN AND DETAIL 91E8.1 FOR WIRING AND MODEL NUMBERS. SEE DETAIL 818.1 FOR MORE DETAIL. SURFACE MOUNT 1" CONDUIT, FOR ENERGY MANAGEMENT SYSTEM AND LIGHTING CONTROL PANEL, FROM 5'-0"AFF TO JOIST SPACE WITH 90 DEGREE RADIUS BEND (AT JOIST), AND NYLON BUSHINGS AT EACH END. COORDINATE REQUIREMENTS WITH MODULAR WALL BEFORE ROUGH -IN. 1<�>PROVIDE CONDUIT FROM'KNOX BOX TO ACCESSIBLE CEILING SPACE. VERIFY WITH ARCHITECTUAL ELEVATION FOR LOCATION OF'KNOX' BOX. O JUNCTION BOX WITH SINGLE GANG MUD RING MOUNTED AT 20" AFF, UNLESS OTHERWISE NOTED, 1" CONDUIT TO JOIST SPACE WITH 90 DEGREE RADIUS BEND (AT JOIST), AND NYLON BUSHINGS AT EACH END. sO JUNCTION BOX WITH SINGLE GANG MUD RING MOUNTED AT 20" AFF, UNLESS OTHERWISE NOTED, 1" CONDUIT TO JOIST SPACE WITH 90 DEGREE RADIUS BEND, AND NYLON BUSHINGS AT EACH END. EXTEND CONDUIT TO SALES FLOOR. OEXTEND CONDUIT 24" FROM FACE OF SALES FLOOR WALL. 8O SURFACE MOUNT (1) 2" CONDUIT FROM TOP OF TELEPHONE BACK BOARD TO JOIST SPACE WITH 90 DEGREE RADIUS BEND (AT JOIST), AND NYLON BUSHING AT EACH END. OSURFACE MOUNT (1)1" CONDUIT FROM 8'-2" AFF, UNLESS OTHERWISE NOTED, TO JOIST SPACE, WITH A 90 DEGREE RADIUS BEND (AT JOIST), AND NYLON BUSHINGS ON EACH END. CONDUIT SHALL BE INSTALLED PRIOR TO PAINTING OF WALL, NO EXCEPTIONS. 10 (2) 4" CONDUITS AT DECK THROUGH RECEIVING WALL, EXTEND CONDUIT 2'-0" FROM FACE OF WALL ON EACH SIDE. PROVIDE NYLON BUSHING ON EACH END. (2) 2" EMPTY CONDUITS WITH PULL LINES FROM LP OFFICE CEILING SPACE TO JOIST SPACE WITH 90° BEND. PROVIDE NYLON BUSHINGS ON EACH END. RUN CONDUIT IN VESTIBULE CEILING SPACE TO LP OFFICE WHEN REQUIRED. CODNUIT AT JOIST SPACE TO TERMINATE AT A LOCATION SUITABLE FOR ACCESS BY BEST BUY VIA LIFT FROM SALES FLOOR. PROVIDE 2" CONTINUOUS CONDUIT FROM PHONE BOARD TO COMMUNICATION ROOM PATHWAY. 1. NO SECTION OF CONDUIT SHALL BE LONGER THAN 100' BETWEEN PULL POINTS (e.g. TELECOMMUNICATIONS CLOSET OR PULL BOX). 2. NO SECTION OF CONDUIT SHALL CONTAIN MORE THAN TWO 90 DEGREE BENDS, OR EQUIVALENT BETWEEN PULL POINTS. 3. THE INSIDE RADIUS OF A BEND SHALL BE AT LEAST 10 TIMES THE INTERNAL DIAMETER AND NOT CONTAIN ANY KINKS OR OTHER DISCONTINUITIES THAT MAY DAMAGE CABLE SHEATHING DURING PULLING OPERATIONS. 4. PULL BOXES MUST BEA MINIMUM OF 8" WIDE, 36" LONG AND A DEPTH OF 4". BOXES SHALL BE INA STRAIGHT SECTION OF CONDUIT AND NOT USED IN LIEU OFA BEND. THE CORRESPONDING CONDUIT ENDS SHALL BE ALIGNED WITH EACH OTHER. 5. CONDUITS SHALL BE REAMED TO ELIMINATE SHARP EDGES. METALLIC CONDUIT SHALL BE TERMINATED WITH AN INSULATED BUSHING. 6. THE PATHWAY MUST BE LABELED AT ENDPOINTS LOCATED IN TELECOMMUNICATIONS CLOSETS, EQUIPMENT ROOMS OR ENTRANCE FACILITIES. FIXED WITHIN 6" OF ENDPOINT AND POSITIONED TO BE VISIBLE. LABELS SHALL BE RESISTANT TO ENVIRONMENTAL CONDITIONS AT THE POINT OF INSTALLATION (MOISTURE, HEAT, OR ULTRAVIOLET LIGHT), AND SHOULD HAVE A DESIGN LIFE EQUAL TO OR GREATER THAN THAT OF THE LABELED COMPONENT. THE LABEL SHALL READ; "LEC Fiber- MPOEIComm Room JR -A)", BLACK ARIAL FONT, 36 POINT, BOLD ON 2" x 10" (MINIMUM) WHITE LABEL. 7. CONDUITS SHALL BE PROVIDED WITH CONTINUOUS PULLSTRING OR ROPE. <8>PROVIDE (1) EMPTY SURFACE MOUNTED 4" CONTINUOUS CONDUITS WITH PULL LINES FROM WALL AT B'-0" A.F.F. TO JOIST SPACE USING 3' -0"+ - RADIUS SWEEPS TO MAKE THE BENDS, AND WITH NYLON BUSHINGS AT EACH END. <3>PROVIDE (2) EMPTY SURFACE MOUNTED 4" CONTINUOUS CONDUITS WITH PULL LINES FROM COMM. ROOM WALL AT V-0-A.F.F. TO JOIST SPACE USING 3'-0"+- RADIUS SWEEPS TO MAKE THE BENDS, AND WITH NYLON BUSHINGS AT EACH END. CONDUIT TO PENETRATE SALES FLOOR WALL IN JOIST SPACE. PROVIDE (3) EMPTY SURFACE MOUNTED 4" CONTINUOUS CONDUITS WITH PULL LINES FROM COMM. ROOM WALL AT 8'-0" A.F.F. TO JOIST SPACE USING 3'-0"+- RADIUS SWEEPS TO MAKE THE BENDS, AND WITH NYLON BUSHINGS AT EACH END. CONDUIT TO PENETRATE SALES FLOOR WALL IN JOIST SPACE. PROVIDE OUTSIDE WEATHER HEAD AND EMPTY CONDUIT FOR THE BEST BUY ANTENNA CABLING. FIELD VERIFY EXACT LOCATION WITH BEST BUY Co. BEFORE PROCEEDING. REFER TO ARCHITECTURAL DETAIL. TELEVISION AND RADIO ANTENNAS SHALL HAVE APPROVED LIGHTNING ARRESTORS PROPERLY GROUNDED IN CASES WHERE THE DIPOLE AERIAL IS INSULATED FROM THE SUPPORTING METAL MAST, THE METAL MAST SHALL BE GROUNDED AND THE DIPOLE CONNECTED TO AN APPROVED LIGHTNING ARRESTOR. JUNCTION BOX FOR BUZZER LOCATION. PROVIDE 24V BUZZER. SEE E2, POWER PLAN. SEE DETAIL 91E8.1 FOR WIRING AND MODEL NUMBERS. SURFACE MOUNTED JUNCTION BOX WITH SINGLE GANG MUD RING MOUNTED AT 44" AFF, UNLESS OTHERWISE NOTED, SURFACE 1" CONDUIT TO JUNCTION BOX AT CORNER OF WALL AND UP TO JOIST SPACE WITH 90 DEGREE RADIUS BEND, EXTEND CONDUIT TO SALES FLOOR. PROVIDE NYLON BUSHINGS AT ENDS OF EACH CONDUIT. JUNCTION BOX FOR BELL LOCATIONS. PROVIDE 120V BELLS. SEE PLAN SHEET E2, POWER PLAN. SEE DETAIL 918.1 FOR WIRING AND MODEL NUMBERS. NO CONDUIT TO BE RUN IN FRONT OF WINDOWS. NO EXCEPTIONS. SEE SHEET E8.0, DETAILS, FOR SENSORMATIC CONNECTIONS AND UNDERFLOOR RUNS. LEC TELCO ENTRANCE FACILITY; MAIN POINT OF ENTRY (MPOE). SEE SHEET 21E5 FOR MORE INFORMATION. PROVIDE SINGLE GANG JUNCTION BOX FOR ALARM KEYPAD. 3 REVIEWED .FOR COMPLIANCE WITH NFPA 70 - NEC JAS! 13 2016 _cdity of -Tukwila i BUILDING DIVISION 11 F-- z 0 as •- p •- ZN�MM o V �v- v JAN^� V C=c,a mvs Za © z =Z,.Q E ��co® YQ J�� C v C N `c 30J 0 vI-- �z0. J W v La I- LL, Q$ZZ goy he m;tFn aZO 1-aoo�G=W W JOEL #: 416752-040 SQ. FT. CALCS RETAIL: 38,966 SF OFFICES & 76 S F ASSEMBLY: 8 `J STORAGE/ 4 890 SF REMAINING: INSTALL: 11153 SF TOTAL. 453885 SF REMODEL AREA: 69767 SF CONCEPT: 45K CS1.9 CONCEPT DATE: xx.xx.xx G.O. -21 FIXTURE REL. xx.xx.xx G.O. -13 FINAL REL. XX.XXXx PROTOTYPE DATE: xx.xx.xx STORE NUMBER: 0447 UI_ 1 Rim UI_ 1 2 CKTS EC TO EXTEND CIRCUITS AS REQUIRED FOR CONNECTION TO RELOC SYSTEM AS SHOWN (TYPICAL). CKT '— DISCONNECT RELOC BETWEEN — \ PLUGSTRIPS PRIOR TO CONNECTION OF NEW OVERHEAD CIRCUITS '—VERTICALLY MOUNTED RELOC PLUGSTRIP FURNISHED WITH FIXTURE. TO BE INSTALLED IN PRE-CUT LOCATIONS. REFERENCE FIXTURE INSTALL INSTRUCTIONS. (TYPICAL) INTERCONNECTING RELOC FURNISHED _� 1 CKT WITH FIXTURE. (TYPICAL) SONY PAD PROVIDE MC CABLE, CONDUIT, OR FLEX AS ALLOWED BY CODE AND STANDARD QUAD RECEPTACLES IN FIXTURE. DO NOT USE AMP WITHIN VENDOR PAD. SONY PAD BACK WALL WILL BE FURNISHED WITH PLUGSTRIPS AND RELOC WIRING FOR INTERCONNECTIONS. CONTRACTOR TO CONNECT PRE-INSTALLED 15' WHIP TO EXISTING TV WALL CIRCUITS LOCATED AT BACK WALL. ENLARGED VENDOR PAD 1 NOT TO SCALE SITE SPECIFIC 244" 7I'3 i7: 2' HE ET i i 4' Liz!] 4' :U 2' -- -----SONY 12„ -- f BEHIND LIGHT BOX. ,ED VIA LIGHTING CONTACTOR. 1 CKT -�-}�— SITE SPECIFIC --- �------- HE ET —� I i SEE WIRING DETAIL 61E4.0 HEET WALL 2 NOT TO SCALE 2' SEE WIRING DETAIL 61E4.0 (TYPICAL) 2' 24'-0" 1 SONY ALTERNATE (FOR USE WHERE RELOC SYSTEM IS NOT ALLOWED) BEHIND LIGHT BOX. .ED VIA LIGHTING CONTACTOR. 6' ---►)—•— 6' —� sm Ew 42" 16" SONY ALTERNATE 3 NOT TO SCALE 12" GENERAL NOTES 1. CONDUITS, RACEWAYS, ELECTRICAL DUCTS & BOXES AND EXPOSED LOW VOLTAGE WIRE SHALL BE RUN TRUE, PLUMB AND SQUARE TO THE BUILDING AND TIGHTLY WRAPPED OR FASTENED Z�v- TO STRUCTURE. LOW VOLTAGE RUNS OR EXPOSED WIRE MUST BE HIDDEN FROM VIEW AND TIE WRAPPED TO THE STRUCTURE WITH WHITE WRAPS. TIE WRAPS MUST BE UNIFORMLY SPACED WITH ENOUGH WRAPS TO PREVENT WIRE FROM SAGGING. UNDER NO CIRCUMSTANCES CAN EXPOSED WIRE BE RUN IN FREE AIR OR DIAGONALLY. 2. ELECTRICAL BOXES ON OPPOSITE SIDES OF FIRE RATED WALL SHALL BE SEPARATED BY A MINIMUM OF 24". 3. USE PLENUM RATED CABLE, CONDUIT, BOXES, ETC. IN AIR PLENUM WALLS AND CEILINGS. ALL PENETRATIONS OF FIRE RATED WALLS ARE TO BE COMPLETELY FIRE SEALED. 4. RUN ELECTRICAL EQUIPMENT, CONDUIT AND WIRING ABOVE BOTTOM OF JOISTS AND AS TIGHT TO THE DECK AS POSSIBLE, COORDINATE THIS WORK WITH OTHER TRADES BEFORE o=- OJ �z00 PROCEEDING. 5. THE ELECTRICAL CONTRACTOR SHALL VERIFY VOLTAGE RATINGS OF NEW OR RELOCATED LIGHTS, SIGNS, COMPACTORS, RTU'S, EXHAUST FANS, MOTORS, ETC. TO AVOID ANY DAMAGE TO ems: EQUIPMENT WHEN ENERGIZED. IT WILL BE THE SOLE RESPONSIBILITY OF THE ELECTRICAL CONTRACTOR TO REPAIR OR REPLACE ANY EQUIPMENT DAMAGED BY BEING CONNECTED TO THE a3ZO H oiMWW WRONG VOLTAGE AT NO COST TO BEST BUY. 6. BRANCH CIRCUIT CONDUCTORS SHALL BE IDENTIFIED AT JUNCTIONS, DEVICES, SPLICES AND TERMINATIONS. WHEN A NEUTRAL CONDUCTOR IS REQUIRED, THE NEUTRAL CONDUCTOR SHALL BE IDENTIFIED WITH CORRESPONDING PHASE CONDUCTOR WHICH FORMS THE BRANCH CIRCUIT. 7. ISOLATED GROUND CIRCUIT MUST HAVE A SEPARATE GROUNDING WIRE AS A DEDICATED GROUND (NOT NEUTRAL). ALL GROUND WIRES SHALL BE CONNECTED TO A COMMON ISOLATED GROUND BUS AT THE PANELBOARD. 8. OUTLET HEIGHTS WILL BE TO CENTER OF OUTLET, UNLESS OTHERWISE NOTED. 9. DO NOT SCALE FROM THIS PLAN. USE SITE SPECIFIC MAP FOR FIXTURE LOCATIONS. 10. ALL RECEPTACLES SHALL BE 20 AMP, UNLESS OTHERWISE NOTED. 11. WHERE UNGROUNDED CONDUCTORS ARE INCREASED IN SIZE, EQUIPMENT GROUND CONDUCTORS, WHERE INSTALLED, SHALL BE INCREASED IN SIZE PROPORTIONATELY ACCORDING TO CIRCULAR MIL. AREA OF THE UNGROUNDED CONDUCTORS. 12. PROVIDE BRUSHED STAINLESS STEEL WALL COVER PLATES. 13. CONTRACTOR TO VERIFY CIRCUITS ARE UNSWITCHED VIA EMS PRIOR TO RE -USE FOR GONDOLA POWER. ONLY UNSWITCHED CIRCUITS MAY BE RE -USED FOR GONDOLA POWER, DISCONNECT SWITCHED CIRCUITS BEING RE -PURPOSED FROM EMS CONTROL PRIOR TO RE -USE. VERIFY CIRCUIT IS NOT BEING USED IN OTHER AREAS PRIOR TO REMOVAL FROM EMS AND RE -USE. 14. FLOOR BOXES ARE EXISTING TO REMAIN. REMOVE COVER AND POLISH BRASS. REINSTALL COVER OVER NEW FLOORING. IF COVER IS BROKEN, REPLACE WITH EXISTING COVER FROM UNDER GONDOLA. IF NONE AVAILABLE FOR REUSE, PROVIDE NEW MATCHING COVER AS REQUIRED. 15. IF PRE -MANUFACTURED WIRING SYSTEMS (MC CABLE, AMPINNERGY, RELOC SYSTEMS) ARE NOT ALLOWED BY AUTHORITY HAVING JURISDICTION PROVIDE EMT CONDUIT AND FLEX AS ALLOWED BY CODE. TURN OVER ANY UNUSED AMPINNERGY PRODUCTS TO BEST BUY. 16. IF STORE UTILIZES EXISTING TRENCH POWER PROVIDE NEW OVERHEAD CIRCUITS TO FIXTURES IN HOME THEATER TRANSFORMATION AREA. DO NOT RE -USE TRENCH SYSTEM. 17. ALL EXPOSED CONDUIT TO BE PAINTED WHITE PRIOR TO INSTALLATION. 18. IF FIXTURE EXTENSIONS ARE NOT AVAILABLE, EC TO PROVIDE EMT DROPS TO FIXTURE. PROVIDE 314" EMT FOR POWER AND 1" EMT WITH PULLSTRING AND NYLON BUSHINGS FOR LOW VOLTAGE AT EACH DROP LOCATION. 19. REFERENCE HOME THEATER MASTER STORE LIST ON PROJECTMATES. FOR SCOPE QUESTIONS ASK BBY CPM. 20. MARK J -BOXES AT DECK IF FOUND TO BE CONTROLLED BY EMS SYSTEM FOR FUTURE REFERENCE. POWER PLAN KEYED NOTES OLOCATE EXISTING JUNCTION BOX ON WALL FOR FORMER TELEVISION DISPLAY. PROVIDE CONNECTION TO RELOC SYSTEM. EXTEND ADDITIONAL CIRCUITS ALONG TOP OF DISPLAY TO CONNECT WITH VENDOR PROVIDED RELOC SYSTEM. 2O LED SIGN IN HEADER ABOVE. CIRCUIT VIA LIGHTING CONTACTOR. DO NOT USE RELOC SYSTEM FOR CONNECTION. VERIFY EXISTING CONTROLS, PROVIDE PILOT RELAY(S) AND CONTACTOR(S) AS REQUIRED. ALL SIGNAGE AND DISPLAY LIGHTING (BACK LIGHTING) TO BE CONTROLLED VIA EMS. DEMOLITION NOTE CONTRACTOR TO MAXIMIZE RE -USE OF ALL EXISTING CIRCUITS. MAINTAIN EXISTING CIRCUITS WHEREVER POSSIBLE AND REDISTRIBUTE AS SHOWN ON DRAWINGS. LABEL ANY UNUSED CIRCUITS FOR FUTURE USE AND MARK LOCATION ON ASBUILT DRAWINGS. NOTE TO CONTRACTOR CONTRACTOR TO RE -USE EXISTING FIXTURE LEVEL AMPINNERGY FLEXIBLE WIRING SYSTEM. TURNOVER ANY UNUSED AMPINNERGY PRODUCTS TO BEST BUY. MAXIMUM OF 10 DUPLEXES OR EQUIVALENT ALLOWED ON A CIRCUIT. CIRCUIT QUANTITIES SALES FLOOR CIRCUITS ARE EXISTING IN CEILING. EC TO FIELD VERIFY EXACT CIRCUIT LOCATIONS IN CEILING AND REDISTRIBUTE AS SHOWN UNLESS NOTED OTHERWISE. REVIEWED.FOR COMPLIANCE WITH NFPA 70 - NEC JAN 13 2616 City ofTukwila BUILDING DIVISION RECEIVED CITY OF TUKWILA JAN 0 6 20"16 PERMIT CENTER 13zo floNor�-pr- Z�v- V m wz N zoY>��°0 Z Z,, E —i°�- 1• o=- OJ �z00 vLa0 a ems: CM m a3ZO H oiMWW n� c c CD laI co O 7 N c U c .°' "t LL m L V U) L E r� RN N p vv o W cc 6) _r + N t � is Q .� u U_ E JOB #: 416752-040 SQ. FT. CALCS RETAIL: 38,966 SIF OFFICES & 76 SIF ASSEMBLY: 8 v STORAGE/ 4,890 SF REMAINING: INSTALL: 11153 SIF TOTAL: 45,885 SF REMODEL AREA: 65767 SIF CONCEPT: 45K CS1.9 CONCEPT /DATE: /�� �v/�v/ M.M.M G.O. -21 FIXTURE REL. XX.XX.XX G.O.-13XFINAL REL. ��//��// M.M.M PROTOTYPE //DATE: � ��//�� M.M.M STORE NUMBER: 0447 BID & PERMIT SET 12-04-15 ENLARGED HT AREA POWER PLAN E1.2 1• a ems: BID & PERMIT SET 12-04-15 ENLARGED HT AREA POWER PLAN E1.2 O B i MATCHLINE MATCHLINE ENLARGED PAC SALES PLAN 114" =1'-0" WIRING FOR HOODS, MICROWAVES, REFRIGERATORS, AND LIVE OVENS TO BE ROUTED ACROSS THE TOP OF THE I -WALL AND UP TO DECK THROUGH BEST BUY FIXTURE EXTENSION. NO WIRING TO PENETRATE I -WALLS. ALL CONNECTIONS TO BE MADE AT TOP OF I -WALL (TYPICAL). DUPLEX OR QUAD AS CALLED FOR ON FLOORPLAN TO BE MOUNTED TO TOP OF I -WALL FOR PLUG IN CONNECTION OF REFRIGERATOR (TYPICAL). I -WALLS WILL COME WITH PRE-INSTALLED 20' WHIP AND JUNCTION BOX IN PROPER LOCATION FOR EQUIPMENT. I -WALLS WILL COME WITH PRE-INSTALLED JUNCTION BOX WITH 20' MC WHIP. ELECTRICIAN TO PULL WHIP UP TO TOP OF I -WALL AND PROVIDE CONNECTIONS. ELECTRICIAN SHALL ALSO PROVIDE RECEPTACLE IN BOX AND MAKE FINAL CONNECTIONS. PAC SALES I -WALL RECEPTACLE MOUNTING AND WIRING DETAIL NO SCALE 4) MOUNT FIXTURE EXTENSION 2" IN FROM EDGE OF COUNTERTOP IN PRE -FINISHED HOLES. 17" PLACE RECEPTACLE IN OPEN FILLER PANEL TO LEFT OF PRINTER 3' PLUG STRIPS 12" AFF (CKT. 2) AFF (CKT. 1) 1O (TYPICAL) 20" AF (CK (CKT. 1) 20" AFF ( lT. 2) PAC SALES CUSTOMER SERVICE COUNTER NO SCALE LH -30 LH -32--////7Q MATCHLINE GENERAL NOTES 1. ALL DEVICES, JUNCTION BOXES, CONDUITS, AND WIRES SHALL BE CONCEALED UNLESS OTHERWISE NOTED. 2. SEE ARCHITECTURAL DETAILS FOR EXACT LIGHT FIXTURE MOUNTING LOCATIONS. 3. INSTALL ALL WIRING TIGHT TO FRAMING AT TOP OF DISPLAY FIXTURES. 4. PROVIDE MULTIPOLE BREAKER OR HANDLE -TIE ON BREAKERS FOR ALL SHARED NEUTRAL CIRCUITS. 5. CONTRACTOR TO VERIFY CIRCUITS ARE UNSWITCHED VIA EMS PRIOR TO RE -USE FOR GONDOLA POWER. ONLY UNSWITCHED CIRCUITS MAY BE RE -USED FOR GONDOLA POWER. 6. EXISTING FLOOR BOXES IN PAC SALES, MAGNOLIA DESIGN CENTERS, AND VENDOR PADS TO BE REMOVED AND FILLED IN. ANY FLOOR BOXES WHERE POWER IS INTERRUPTED BY REMOVAL OF BOXES IN AFOREMENTIONED AREAS SHALL ALSO BE REMOVED AND FILLED IN. TURN OVER ANY SALVAGEABLE FLOOR BOX COMPONENTS TO BEST BUY FOR RE -USE ON DAMAGED FLOOR BOXES THAT ARE EXISTING TO REMAIN. KEYED NOTES O10', 5, AND 3 PLUG STRIPS TYPE WIREMOLD AS SHOWN ON PLANS. 10' PLUG STRIP CONTAINS 20 SINGLE OUTLETS, 5' PLUG STRIP CONTAINS 8 SINGLE OUTLETS, AND T PLUG STRIPS CONTAINS 9 SINGLE OUTLETS. PLUG STRIPS ARE TO BE FURNISHED BY OWNER AND INSTALLED BY E.C. OPROVIDE 60A -2P CONTACTOR 120V COIL AND 2 -HOUR WIND-UP TIMER TO CONTROL CONTACTOR FOR "LIVE OVEN" OPERATION. LOCATE CONTACTOR AND WIND-UP TIMER IN CABINET ABOVE "LIVE OVEN" FACING FORWARD IMMEDIATELY BEHIND CABINET DOOR TO CONTROL OVEN. PROVIDE CONNECTION FROM CONTACTOR TO "LIVE OVEN" AND WIRE COMPLETE. LIVE OVENS TO BE FED WITH 3!4" C. (3) #8 AND #8 GND. CONTACTOR COIL TO BE FED WITH (2) # 12. O3 PROVIDE J -BOX ON TOP OF I -WALL FOR CONNECTION TO HOOD EXHAUST FAN. PROVIDE CONNECTION WITH CONCEALED FLEX OR CONDUIT AS ALLOWED BY CODE FROM J -BOX TO HOOD EXHAUST FAN. COORDINATE WITH FIXTURE INSTALLER BEFORE ROUGH -IN. OPROVIDE RECEPTACLE IN PRE-INSTALLED JUNCTION BOX. JUNCTION BOX WILL BE PROVIDED WITH 20' MC WHIP FOR CONNECTION TO POWER FEED AT TOP OF I -WALL. ELECTRICIAN TO ROUTE WHIP UP TO TOP OF I -WALL AND PROVIDE FINAL CONNECTION. SEE DETAIL 2 THIS SHEET FOR MORE INFORMATION. 5O POWER TO EQUIPMENT TO BE ROUTED THROUGH FIXTURE EXTENSION FURNISHED BY FIXTURE SUPPLIER. ALL DROPS/FIXTURE EXTENSIONS TO BE AT REAR OF I -WALL. ROUTE MC CABLE DOWN FIXTURE EXTENSION AND ALONG TOP OF I -WALL TO APPROPRIATE EQUIPMENT. OPROVIDE SURFACE MOUNTED CONDUIT DOWN WALL TO TOP OF I -WALL. ROUTE POWER ALONG TOP OF [-WALL IN CHANNEL TO CONNECTION POINTS. TAKE CARE TO CONCEAL WIRING FROM VIEW. OMOUNT TRACK TO DECORATIVE GRID ABOVE COUNTER. ROUTE MC CABLE DOWN GRID SUPPORT FURTHEST FROM THE CENTER OF STORE. ROUTE CABLE ON TOP OF GRID AND TAKE CARE TO CONCEAL FROM VIEW AS MUCH AS POSSIBLE. PROVIDE NIPPLE THROUGH HANGING GRID FOR CONNECTION INTO TRACK LIGHTING. DO NOT RUN MC CABLE AROUND OUTSIDE OF HANGING GRID. LAMP TO BE HUN AT 6' AFF TO BOTTOM OF FIXTURE: FIXTURE TYPE: CONTECH RLMA1596N-P SHADE: MLA106-W TRACK: CONTECH WHITE. LAMP TYPE: (1)11W LED PHILLIPS 11A191ENDI2700.DIM.611. OPROVIDE RECEPTACLE AT TOP OF I -WALL AS SHOWN FOR PLUG IN CONNECTION OF EQUIPMENT. OPROVIDE CONNECTION FROM OVERHEAD HIGH BAY LIGHTING CIRCUIT. PROVIDE STEP DOWN TRANSFORMER RIB#TRV40VA013 FOR STEP DOWN TO 120V. <8>QUAD RECEPTACLES FOR FREESTANDING APPLIANCE DISPLAYS TO BE MOUNTED TO FIXTURE EXTENSION @ 8" A.F.F. , AND NOT TO FLOOR, AND MUST FACE WALL AND RACETRACK. REFERENCE CONSTRUCTION MANUAL FOR MORE INFORMATION. 11 ROUTE FLEX SECURED TIGHT TO A REAR SUPPORT CABLE OF CEILING GRID. <8>MOUNT RECEPTACLE INSIDE UPPER CABINET MOUNTED TIGHT TO THE BOTTOM OF THE CABINET FOR MICROWAVE CONNECTION. PROVIDE DEDICATED CIRCUIT TO RECEPTACLE FOR FINAL CONNECTION. NOTE TO CONTRACTOR AMPINNERGY FLEXIBLE WIRING SYSTEM MAY NOT BE USED IN PAC SALES AREA. REVIEWED .FOR COMPLIANCE WITH NFPA70 - NEC JAS! 13 1016 City ofTuIcWila i BUILDING DIVISION. RECEIVED CITY OF TtJKWILA JAN 06 26 PERMIT CENTER 1—z�aov-0CD '� zN,*M^ 0 1UW— v� Win"" _min Io v zz„N E i=:R .. OZN OJ 0 v�3 �v �zn. OFc � � Na J I- W •• Ugzz a c= c.m%m �ZOR PSoo2c.u. W c c c c v L0 a� r N U co L U `E U 2 0 ti O V d Q c � d o co R ; z N K O_ R M wa cv_ R o -E; -0r r o JOB #: 416752-040 SQ. FT. CALCS _ RETAIL: 38,966 SF OFFICES a 876 S F ASSEMBLY: STORAGE! 890 S F REMAINING: 4 INSTALL: 11153 S F TOTAL. 45,885 SF REMODEL AREA: 6 767 SF 7 CONCEPT: 45K CS 1.9 CONCEPT //DATE: //��// .��// MM G.O.-21��FIXTURE //REL. �v/�v/ M.M.M G.O.-13xFINAL REL. ��//��// M.M.M PROTOTYPE DATE: ��//��// M.M.M STORE NUMBER: 0447 BID & PERMIT SET 12-04-15 REV DATE 0 0 FAlk 0 0 ENLARGED PAC SALES PLAN E2.0 AI .. • s BID & PERMIT SET 12-04-15 REV DATE 0 0 FAlk 0 0 ENLARGED PAC SALES PLAN E2.0 OF '�?. :s'rc CSi. �Z.`•S:L1'��f.�'� MSX.^.t.SRd£d'S^?nd �T ��S 9^".".'*M'.'.':�:: '^.S?x Y"�^^''�".41"..U..�.:�. L:�Y?a, :l.'SK:;s:.SE�". L.:',+9.�� .. �"B�S;S�„ a ENLARGED ELECTRICAL POWER PLAN AT FRONT OFFICE 114" =1'-0" KEY NOTES PROVIDE SURFACE MOUNTED CONDUIT DOWN WALL TO TOP OF FIXTURE AND ROUTE MC CABLE DOWN IN FIXTURE, FROM RECEPTACLE TO RECEPTACLE ROUTE MC CABLE UP OVER TOP OF FIXTURE AND DOWN TO NEXT RECEPTACLE LOCATION. 2OMOUNT RECEPTACLE TO FIXTURE T ABOVE MIDDLE SHELF. 3O MOUNT RECEPTACLE TO FIXTURE T ABOVE BASE DECK. TAKE CARE TO ASSURE RECEPTACLE DOES NOT INTERFERE WITH OPENEING OF BASE DECK. OE.0 TO PROVIDE (2) SINGLE GANG DUPLEX RECEPTACLES INSIDE EACH 4' SECTION OF BLACK FIXTURE CHASE. 5O SURFACE MOUNT (1)1" CONDUIT FROM 8'-2" AFF, UNLESS OTHERWISE NOTED, TO JOIST SPACE, WITH A 90 DEGREE RADIUS BEND (AT JOIST), AND NYLON BUSHINGS ON EACH END. I 1 6O PROVIDE DEDICATED CIRCUIT FOR T.V. AND COORDINATE EXACT MOUNTING REQUIREMENTS IN FIELD WITH BEST BUY CONSTRUCTION PROJECT MANAGER. H n OL D ++ V Q' S N C cv O U C 3 L U 0 ,2 E i+ R 0 S 0 .0 - C LA 0 U C n N U) (D E c6 R JOB #: 416752-040 SQ. FT. CALCS RETAIL: 383966 ZNd,MM V fW—� p pWIn`-' MCC �Q my .x � z Z., E pzz �Weq�® REMODEL AREA: 6 767 7 go -�[ z zc O J �a0. CONCEPT: ��v FE OQWW J W0- CJ• v Q$ZZ..� mem H$�w n OL D ++ V Q' S N C cv O U C 3 L U 0 ,2 E i+ R 0 S 0 .0 - C LA 0 U C n N U) (D E c6 R JOB #: 416752-040 SQ. FT. CALCS RETAIL: 383966 SF OFFICES a 876 .ASSEMBLY: S F STORAGES 4,890 REMAINING: SF INSTALL: 13153 SF TOTAL: 459885 SF REMODEL AREA: 6 767 7 SF 1 CONCEPT: 45K CS 1.9 CONCEPT DATE: ////��// .x��// M M.M.M G.O.-13 FINAL R��E//L../ ��//��// M.M.M PROTOTYPE DATE: M��/��// .��M.M STORE NUMBER: 0447 BID & PERMIT SET 12-04-15 REVIEWED _FOR COMPLIANCE WITH NFPA 70 a NEC JAN 13 2016 City of Ttxltwila � BUILDING DIVISION RECEIVED CITY OF TUKWILA JAN 0 6 2016 PERMIT CENTER 0 0 � a Q 0 Q r „ 1 I BID & PERMIT SET 12-04-15 REVIEWED _FOR COMPLIANCE WITH NFPA 70 a NEC JAN 13 2016 City of Ttxltwila � BUILDING DIVISION RECEIVED CITY OF TUKWILA JAN 0 6 2016 PERMIT CENTER 0 0 � a Q 0 Q DATE ENLARGED PPLAN E2.1 TPANEL SCHEDULES NO SCALE Panel: DPI I SERVICE 1200A MCB GFP Volta e: ` 120/208v 3Ph 4w x x e: 1201208v, 3Ph, 4w Code Code L- VA C- VA Code Code Code R - VA M - VA E -VA Description Amp /pole No. i Ph Am P No. /pole Code Code Code L -VA C -V -VA Description A R Code -V M A Code -V E A 0 15080 600 3400 0 EXISTING PANEL LB 200 1 - A - 2 200 EXISTING PANEL LD 0 18160 3000 0 0 0 17560 2500 2500 0 0 0 .0' 1 3 -B- 4 / 1. 0 17080 1200 i 900 0 4001 5160 2800 0 0 0 0 0 3 5 G- 6 3 11600 17680 2500 0 0 0 0 5260 SPACE ONLY - 7 - A - 8 SPACE ONLY SPACE ONLY 1000 7 0 7460 SPACE ONLY - 9 - B - 10 SPACE ONLY . SPACE ONLY 2011 EXISTING FLOOR RECEPTS. 0 6520 SPACE ONLY EXSITING CONDENSATE PUMP P-1 11 . C - 12 - SPACE ONLY SPACE ONLY - B - 0 33240 0 34640 1000 32840 3600 3400 0 : 3700 3400 0 5300 0 0 400 / 3 Main Breaker 1 -A'- - B - - C . Through Feed Lug Conn NONE NONE I NONE 14 SPACE ONLY - A - - B - - C - Total - C - I SPACE ONLY - 15 Bus KVA loads Dmd Conn 40.2 41.7 39.1 121.1 Connected RVA Totals1.1. 2011 13 SPACE ONLY 14 Lighting .-Code L 1.3 1.0 PanelboaM Notes. 1400 1 14 0 15380 0 17100 0 1 12680 9780 4300 0 6540 4300 0 1 8540 1 3600 1 0 1 400 / 3 Convenience Receptacles (180 W) -Code C 55.4 100.7 . 1 - . E.C. TO BALANCE EACH PHASE WITHIN 10% FLOOR RECEPTS. . I A - - B - 29.5 1 27.9 - C - Total 1 24.8 1 82.2 lConnected KVA Totals 1000 I I .... . . . . . Receptacles (Non Convenience) - Code R 12.6 12.6 2 - PROVIDE ISOLATED GROUND BUS Dmd 0.0 Conn 0.0 Panelboard Notes EXISTING FLOOR RECEPTS. 1000 125% Largest Motor Motors -Code M 6.8 6.8 . 3- 27.6 45.2 I - A - 20 20/1 Electric Heat - Code E 0.0 0.0 4- 2- PROVIDE ISOLATED GROUND BUS -C-_ EXISTING FIXTURE RECEPTS. 2011 21 - B - Total KVA 76.0 121.1 5-. 2011 1 25 1000 26 EXISTING FLOOR RECEPTS. 20/1 Spare = 0°/ Spare KVA 0 0.0 EXISTNG : Mounting 2011 1 27 1 - B - 1000 2011 Adjusted KVA (Demand + Spare KVA) 76 82.2. EXISTNG :Amps AIC Rating 2011 EXISTING FLOOR RECEPTS. 1000 1 - C - 30 Adjusted Amps (Demand +Spare KVA) 211 .............. 400 : Amp Rating of Bus 1 -13- 1 20/1 EXISTING FLOOR RECEPTS. 1000 KVA (Demand + Spare KVA) 65 --- 400 : Panel Amp Rating (Min Main) 2011 I - C - IProject Number: I Project Name : File Name: Adjusted Amps (Demand + Spare KVA) 1180 Date: 208 :.Phase to Phase Voltage; : Amp Rating of Sus I EXISTING FLOOR RECEPTS. 416752-040 BEST BUY-TUKWILA, WA I PANEL DPI - A - 12/4/2015 TPANEL SCHEDULES NO SCALE Panel:' DP2 LE SERVICE 1200A MCB GFP Volta e:' 120/208v, 3Ph, 4w e: 1201208v, 3Ph, 4w Code Code L- VA C- VA Code Code Code R - VA M - VA E - VA Description Amp /pole No. I Ph Amp No. /pole I Code Code Code Description L- VA C- VA R - VA Code M -VA Code E - VA 0 8720 0 0 0 EXISTING PANEL LA 100 1 -A- 2 150 I EXISTING PANEL LC 0 1400 0 4300 0. 0 6840 0 0 .0' " / 3, - B - 4 1 0 2800 400 4100 _ 0 0. 5560 0 0 0 113 4 5 -C- 6' 3 0 600 1700 3600 0 0 5260 9780 0 0 EXISTING PANEL LF 200 . 7 - A - 8. - SPACE ONLY 1000 7 0 7460 6140 200 0 2 / 9 - B - 10 - SPACE ONLY 2011 EXISTING FLOOR RECEPTS. 0 6520 6840 0 0 EXSITING CONDENSATE PUMP P-1 3 11 - C - 12 SPACE ONLY - B - 10 2011 SPARE SPACE ONLY - 13 - A - 14 SPACE ONLY 2011 11 - C - 12 SPACE ONLY - 15 -B- 16 - SPACE ONLY I EXISTING FIXTURE RECEPTS. 2011 13 SPACE ONLY 14 17 - C - 18 SPACE ONLY 1400 1 14 0 15380 0 17100 0 1 12680 9780 4300 0 6540 4300 0 1 8540 1 3600 1 0 1 400 / 3 Main Breaker -A- B - - C - Through Feed Lug Conn NONE NONE NONE FLOOR RECEPTS. 1000 A - - B - 29.5 1 27.9 - C - Total 1 24.8 1 82.2 lConnected KVA Totals 1000 I EXISTING FIXTURE RECEPTS. 2011 Bus KVA loads Lighting -Code L Dmd 0.0 Conn 0.0 Panelboard Notes EXISTING FLOOR RECEPTS. 1000 EXISTING CUST.. SERV. RECEPTS: EXSITING FIXTURE RECEPTS. 1000 Convenience Receptacles (180 W) -Code C 27.6 45.2 1 - E.C. TO BALANCE EACH PHASE WITHIN 10% - A - 20 20/1 EXISTING FLOOR RECEPTS. Receptacles (Non Convenience) - Code R 24.9 24.9 2- PROVIDE ISOLATED GROUND BUS -C-_ EXISTING FIXTURE RECEPTS. 2011 21 - B - 125% Largest Motor Motors - Code 12.2 12.2 3- 2011 1 25 1000 26 EXISTING FLOOR RECEPTS. 20/1 Electric Heat -Code E 0.0 0.0 4- SPARE 2011 1 27 1 - B - 1000 2011 Total KVA 64.6 82.2. 6- 26 2011 EXISTING FLOOR RECEPTS. 1000 1 - C - 30 Spare -- 0% Spare KVA I 0 EXISTING FLOOR RECEPTS. EXISTNG : MountingAdjusted 1 -13- 28 20/1 EXISTING FLOOR RECEPTS. 1000 KVA (Demand + Spare KVA) 65 1000 EXISTNG : Amps AIC Rating 2011 q - C - 30 2011 Adjusted Amps (Demand + Spare KVA) 1180 1000 2011 400 : Amp Rating of Sus I EXISTING FLOOR RECEPTS. 20/1 31 - A - 32 2011 EXISTING FLOOR RECEPTS. 400 : Panel Amp Rating (Min Main) 700 SPARE 1000 Project Number: I Project Name : File Name: 33 Date: 208 : Phase to Phase Voltage EXISTING FLOOR RECEPTS. 1000 540 200 416752-040 I BEST BUY-TUKWILA, WA PANEL DP2 SPARE 12/412015 TPANEL SCHEDULES NO SCALE Panel: ' Panel: LE SERVICE 1200A MCB GFP IVolta e: e: 1201208v, 3Ph, 4w Code Code L- VA C- VA Code Code L- VA C- VA Code L- VA Code C- VA Code Code CodeAmp R - VA M - VA E - VA Description /pole No. Ph No. Amp /pole Description Code Code Code L- VA C- VA R - VA Code Code M - VA E - VA 0 11120 0 0 0 EXISTING PANEL LH 100 1 - A - 2 2011 EXISTING FLOOR RECEPTS. 1000 EXSITING ENTRY DOORS 0 11300 0 0 0 " / 3 - B - 4 20/1 EXISTING FLOOR RECEPTS. 1000 20/1 1 500 9760 1400 0 0 " 3 5 - C - 6 2011 EXISTING FLOOR RECEPTS. 1000 7 - A . 1200 2 EXISTING COMM UPGRADES 2011 7 -A- 8 2011 EXISTING FLOOR RECEPTS. 1000 2011 EXSITING CONDENSATE PUMP P-1 1000 200 EXISTING COMM UPGRADES 2011 9 - B - 10 2011 SPARE 2011 1 EXSITING FLOOR RECEPTS. i 1000 1000 I EXISTING FIXTURE RECEPTS. 2011 11 - C - 12 20/1 SPARE 1 SPARE - C - 12 1000 I EXISTING FIXTURE RECEPTS. 2011 13 - A - 14 2011 EXISTING FLOOR RECEPTS. 1000 13 1400 1 14 EXSITING FIXTURE RECEPTS. EXISTING FIXTURE RECEPTS. 15 B- 16 2011EXISTING FLOOR RECEPTS. 1000 1000 15 1000 I EXISTING FIXTURE RECEPTS. 2011 17 - C - 18 20/1 EXISTING FLOOR RECEPTS. 1000 EXISTING CUST.. SERV. RECEPTS: EXSITING FIXTURE RECEPTS. 1000 21 EXISTING FIXTURE RECEPTS. 2011 19 - A - 20 20/1 EXISTING FLOOR RECEPTS. 1000 EXSITING FIXTURE RECEPTS. 2011 1000 -C-_ EXISTING FIXTURE RECEPTS. 2011 21 - B - 22 20/1 EXISTING FLOOR RECEPTS. 1000 2011 1 25 1000 26 EXISTING FLOOR RECEPTS. 20/1 23 - C - 24 2011 SPARE 2011 1 27 1 - B - 1000 2011 EXISTING FLOOR RECEPTS. 20/1 1 25 1 - A - 26 2011 EXISTING FLOOR RECEPTS. 1000 1 - C - 30 1000 PAC SALES [-WALL DISPLAY EXISTING FLOOR RECEPTS. 2011 1 27 1 -13- 28 20/1 EXISTING FLOOR RECEPTS. 1000 32 2011 1000 360 EXISTING FLOOR RECEPTS. 2011 29 - C - 30 2011 EXISTING FLOOR RECEPTS. 1000 2011 PAC SALES 1 -WALL DISPLAY 1000 I EXISTING FLOOR RECEPTS. 20/1 31 - A - 32 2011 EXISTING FLOOR RECEPTS. 1000 PAC SALES I -WALL DISPLAY 700 SPARE 1000 SPARE 20/1 33 - B - 34 20/1 EXISTING FLOOR RECEPTS. 1000 540 200 EXISTING FIXTURE RECEPTS. 1000 SPARE EXISTING FLOOR RECEPTS. 20/1 35 - C - 36 20/1 PAC SALES I -WALL DISPLAY 720 200 34 20/1 1000 I EXISTING FLOOR RECEPTS. 20/1 37 - A - 38 1 20/1 1 PAC SALES I -WALL DISPLAY 720 200 0 5260 0 7460 0 6520 1 9780 0 0 6140 200 0 6840 0 0 1 -ib -00 I Main Breaker I EXISTING FLOOR RECEPTS. 20/1 39 -13- 40 2011 PAC SALES I -WALL DISPLAY 540 200 37 -A- 1000 2011 EXISTING FLOOR RECEPTS. 2011 41 - C - 42 12011 1080 SPARE GEEK SQUAD RECEPTS. 2011 0 1400 500 1000 20840 19480 200 0 0 200 0 0 1600 0 0 225 /Breaker 31. Main -A- - B - C - Through -Feed Lug Conn NONE NONE NONE . A . 4.3 1080 -A- 1.2 - B - 22.4 I - C - Total 21.6 45.2 Connected KVA Totals 2- PROVIDE ISOLATED GROUND BUS --- 42 20/1 SPARE 20/1 Bus KVA loads Lighting - Code L Dmd Conn 2.4 1.9 Panelboard Notes: 0.2 0.2 3- I Main. - -- . ,._. Breaker ` -A- -13- - C - Through Feed Lug Conn Convenience Receptacles (180 W) - Code C 37.2 41.3 1 - E.C. TO BALANCE EACH PHASE WITHIN 10% Electric Heat - Code E 0.0 0.0 4- 1 11 Receptacles (Non Convenience) - Code R 2.0 2.0 2- I Bus KVA loads I Lighting -Code L Dmd 0.0 Tota I KVA 37.6 42.2 5- Panelboard Notes: 0 125% Largest Motor Motors -Code M 0.0 0.0 3- Convenience Receptacles (180 W) - Code C 15.6 Spare = 0% . Spare KVA 0 EXISTNG : Mounting BALANCE EACH PHASE WITHIN 10% Panelboard Notes: Electric Heat - Code E 0.0 0.0 4- 0.0 Adjusted KVA (Demand + Spare KVA) 38 EXISTNG : Amps AIC Rating . . 1 - E.C. TO BALANCE EACH PHASE WITHIN 10% � . Total KVA 41.6 45.2 5-1 104 225 : Amp Rating of Bus 12.0 3- II Spare = 0% Spare KVA Spare = 0% Spare KVA 0 EXISTING : Mounting I : Panel Amp Rating (Min Main) 4- 0.0 i Project Number: Project Name : Adjusted KVA (Demand + Spare KVA) 42 EXISTING : Amps AIC Rating Total KVA 18.0 416752-040 IBEST IAdjusted I PANEL LF Amps (Demand + Spare KVA) 115 225 : Amp Rating of Bus Spare =1 0% ; Spare KVA 0 Spare= EXISTING : Mounting 60.0 225 : Panel Amp Rating (Min Main) Project Number: Project Number: lProject Name : IFile Name: Date: 208 : Phase to Phase Voltage 19 0 EXISTINGng 416752-040 i : Mounting BEST BUY-TUKWILA, WA PANEL LE 12/4/2015 TPANEL SCHEDULES NO SCALE Panel: ' LF LA SERVICE 1200A MCB GFP Volta e: 120/208v, 3Ph, 4w 120/208v 3Ph 4w I x x Code Code L- VA C- VA Code Code L- VA C- VA Code Code Code R - VA M . VA E - VA Description AmpAmp /pole No. Ph No. I /pole Description Code I Code Code I L- VA C- VA R - VA Code Code M - VA E - VA Code M - VA 500 EXSITING ENTRY DOORS 2011 1 1 - A - 2 1 50/ PAC SALES LIVE OVEN 3840 20/1 1 GEEK SQUAD RECEPTS. 500 EXSITING ENTRY DOORS 2011 1 3 - B - 4 2 " 3840 - B - 4 500 EXSITING ENTRY DOORS 20/1 1 5 - C . 6 501 PAC SALES LIVE OVEN 3840 20/1 5 500 EXSITING ENTRY DOORS 2011 1 7 - A . 8 2 113840 600 360 1300 EXSITING COUNTDOWN RM RECEPTS. 2011 1 9 - B - 10 2011 EXSITING CONDENSATE PUMP P-1 1080 200 200 - B - EXSITING SALES DEV. RECEPTS. 2011 1 11 - C - 12 2011 1 EXSITING FLOOR RECEPTS. i 1000 GEEK SQUAD RECEPTS. 360 SPARE PAC SALES DISPLAY 2011 13 1 - A - 14 20/1 1 SPARE - C - 12 2011 SPARE SPARE 2011 15 - B - 16 2011 PAC SALES HOOD DISPLAY 500 13 1000 1 14 EXSITING FIXTURE RECEPTS. 201117 20/1 - C - 18 2011 PAC SALES HOOD DISPLAY 500 SPARE 1000 15 EXSITING FIXTURE RECEPTS. 2011 19 - A - 20 2011 EXSITING LIFT TRUCK RECEPT. 400 400 1000 EXISTING CUST.. SERV. RECEPTS: EXSITING FIXTURE RECEPTS. 2011 21 - B - 22 20/1 EXISTING SECURITY PANEL 1 500 DISPLAY RECEPTS. 1000 400 EXSITING FIXTURE RECEPTS. 2011 23 -C-_ 24 2011 EXISTING FIRE ALARM PANEL 1 500 1000 1000 360 EXSITING FIXTURE RECEPTS. 2011 1 25 1 - A - 26 2011 EXISTING SENSORMATIC I 500 2011 1000 1000 EXSITING FIXTURE RECEPTS. 2011 1 27 1 - B - 28 2011 PAC SALES 1 -WALL DISPLAY 1 1260 -C- 1000 I EXSITING FIXTURE RECEPTS. 2011 1 29 1 - C - 30 2011 PAC SALES [-WALL DISPLAY 1 720 400 2011 1000 - A - EXSITING FIXTURE RECEPTS. 2011 1 31 1 - A - 32 2011 DISPLAY RECEPTS. 360 APPLIANCE DISPLAY RECEPTS. 1000 2011 EXSITING FIXTURE RECEPTS. 2011 33 1 - B - 34 2011 PAC SALES 1 -WALL DISPLAY 360 400 APPLIANCE DISPLAY RECEPTS. 1000 1000 EXSITING FIXTURE RECEPTS. 2011 35 - C - 36 2011 PAC SALES I -WALL DISPLAY 700 SPARE 1000 33 EXSITING FIXTURE RECEPTS. 2011 37 - A - 38 2011 PAC SALES 1 -WALL DISPLAY 540 200 EXISTING FIXTURE RECEPTS. 1000 SPARE EXSITING FIXTURE RECEPTS. 20/1 39 - B - 40 20/1 PAC SALES I -WALL DISPLAY 540 400 34 20/1 400 EXISTING EXTERIOR DOOR 20/1 41 - C - 42 2011 EXSITING EMP. STATION APPLIANCES 600 35 0 5260 0 7460 0 6520 1 9780 0 0 6140 200 0 6840 0 0 1 NONE NONE NONE I Main Breaker I - A - . B - - C - Through Feed Lug Conn NONE NONE NONE I I #1 1080 - A - -13- 15.0 13.8 - C - Total 13.4 42.2 Connected KVA Totals 20/1 37 -A- 38 2011 SPARE Bus KVA loads Lighting -Code L Dmd Conn 0.0 0.0 Panelboard Notes: Dmd Conn 0.6 0.5 1080 1000 GEEK SQUAD RECEPTS. 2011 39 Convenience Receptacles (180 W) - Code C 14.6 19.2 1 - E.C. TO BALANCE EACH PHASE WITHIN 10% 20/1 SPARE 1000 . A . 4.3 1080 Receptacles (Non Convenience) - Code R 22.8 22.8 2- PROVIDE ISOLATED GROUND BUS --- 42 20/1 SPARE 20/1 SPARE 125% Largest Motor Motors -Code M 0.2 0.2 3- I Main. - -- . ,._. Breaker ` -A- -13- - C - Through Feed Lug Conn NONE NONE NONE Ei= NONE NONE NONE 0 10320 0 0 11360 400 0 11360 0 Electric Heat - Code E 0.0 0.0 4- 1 11 2- I I Bus KVA loads I Lighting -Code L Dmd 0.0 Tota I KVA 37.6 42.2 5- Panelboard Notes: 19.1 IConvenience _ 1 18.4 1 60.0 IConnected KVA Totals Convenience Receptacles (180 W) - Code C 15.6 Spare = 0% . Spare KVA 0 EXISTNG : Mounting BALANCE EACH PHASE WITHIN 10% Panelboard Notes: 4- Receptacles (Non Convenience) - Code R 0.0 I 0.0 Adjusted KVA (Demand + Spare KVA) 38 EXISTNG : Amps AIC Rating . . 1 - E.C. TO BALANCE EACH PHASE WITHIN 10% � . 9600,125% Largest Motor 1 Motors - Code M Adjusted Amps (Demand + Spare KVA) 104 225 : Amp Rating of Bus 12.0 3- II Spare = 0% Spare KVA 0 _ . -- EXISTING , Electric Heat- Code E 225 : Panel Amp Rating (Min Main) 4- 0.0 i Project Number: Project Name : File Name: Date: 208 : Phase to Phase Voltage Total KVA 18.0 416752-040 IBEST BUY-TUKWILA, WA I PANEL LF I 1214/2015 TPANEL SCHEDULES NO SCALE NOTE TO PLAN REVIEWER: PEAK DEMAND READING FOR PREVIOUS 12 MONTHS OF STORE OPERATION. TAKEN FROM OWNER UTILITY BILL JUN 2015 = 204KW 204KW x 1.25 = 255 KW 1307 AMPS PAC SALES= 29KW 307+29 =336 KW! 404 AMPS EXISTING SERVICE IS 1,200 AMPS STORE IS BEING REMODELED AND EXISTING POWER IS BEING REDISTRIBUTED AT SALES FLOOR. OVERALL CONSUMPTION IS REMAINING THE SAME OR BEING REDUCED. 1. THE ELECTRICAL CONTRACTOR SHALL PROVIDE NEW BREAKERS IN EXISTING GEAR AS REQUIRED. CONTRACTOR TO VERIFY ANY EXISTING SERIES RATINGS ARE IN COMPLIANCE. MAINTAIN AS REQUIRED. MATCH MANUFACTURES AND AIC RATINGS. EXISTING (2) 4 #350 & 1#1 GND. EXISTING I Panel: I I Panel:; LA SERVICE 1200A MCB GFP Voltage: Volta e: 120/208v 3Ph 4w I x x Code Code L- VA C- VA Code Code - L VA CVA Code Code Code -VA R M VA E VA Code .Code -L-- . _.. -. VA C- VA .Code .Code .Code - --__. __.__ __..._.• R - VA M - VA E - VA ---- --_.._. ... .._-... Desal Uon Amp - .--- /pole --- - . ---- No. Ph. No. '/ Am p _._- ole _._..._. _. .....__. Desai tion Code Code Code L- VA C= VA R - VA Code M - VA . Code E - VA Code M - VA 400 1 EXISTING JANITOR RECEPTS. 20/1 1 . I - A - 2 20/1 1 GEEK SQUAD RECEPTS. 1080 EXISTING EF -1 2011 900 400 4 EXISTING BREAK ROOM RECEPTS. 20/1 3 - B - 4 2011 GEEK SQUAD RECEPTS. 1080 EXISTING EF -2 - C - 900 600 EXISTING FLOOR RECEPT. EXISTING BREAK ROOM RECEPTS: 20/1 5 - C - 6 2011 GEEK SQUAD RECEPTS. 1080 SPARE 2011 EXISTING FLOOR RECEPT. 600 360 EXISTING BREAK ROOM. RECEPTS: 2011 7 - A . 8 2011 GEEK SQUAD RECEPTS. 1080 SPARE 1000 - B - 800 1 EXISTING RRIHALL/BREAK RECEPTS. :20/1 9. . B . 10 2011 GEEK SQUAD RECEPTS. 1080 SPARE 1000 I EXISTING FLOOR RECEPT. 20/1 SPARE 2011 11 - C - 12 2011 SPARE 2011 SPARE EXISTING FLOOR RECEPT. 2011 15 -13- SPARE '2011 13 - A - 1 14 2011 SPARE 20/1 SPARE 17 - C - 18 20/1 SPARE 2011 15 - B - 16 `2011 SPARE 2011 SPARE 20 2011 400 1440 EXISTING CUST.. SERV. RECEPTS: 2011 17 - C - 18 2011 SPARE 20/1 SPARE DISPLAY RECEPTS. 1 540 400 360 EXISTING CUST.. SERV. RECEPTS: 20/1 19 - A - 20 2011 EXISTING FIXTURE RECEPTS. 1000 SPARE 360 720 400 DISPLAY RECEPTS EXISTING CUST.. SERV. RECEPTS: 2011 21 . B - 22 2011 EXISTING FIXTURE RECEPTS. 1000 EXISTING RTU RECPTS. 1600 DISPLAY RECEPTS. 400 27 EXISTING CUST'. SERV. RECEPTS. 2011 23 -C- 24 20/1 EXISTING FIXTURE RECEPTS. 1000 EXISTING EXHAUST FANS 20/1 400 1080 30 GEEK SQUAD RECEPTS. 2011 25 - A - 26 12011' -A- EXISTING FIXTURE RECEPTS. 1000 SPARE - A - 32 1080 APPLIANCE DISPLAY RECEPTS. GEEK SQUAD RECEPTS: 2011 27 B- 28 20/1 IXISTING F1XT RERECEPTS. 1000 SPARE 20/1 APPLIANCE DISPLAY RECEPTS. 1080 1000 GEEK SQUAD RECEPTS. 2011 29 - C - 30 20/1 EXISTING FIXTURE RECEPTS. 1000 SPARE 720 33 1080 1000 GEEK SQUAD RECEPTS. 2011 31 - A - 32 : 20/1 EXISTING FIXTURE RECEPTS. 1000 SPARE 1000 -C- SPARE 2011 GEEK SQUAD RECEPTS. 2011 33 -13- 34 20/1 SPARE 2011 SPARE EXISTING EMS SYSTEM 20/1 1 41 - C - SPARE 2011 35 - C - 36 '20/1 SPARE 2011 SPARE - A - - B - - C - Through Feed Lug Conn 1080 1000 GEEK SQUAD RECEPTS, 20/1 37 -A- 38 2011 SPARE 20/1 SPARE Bus KVA loads Lighting -Code L Dmd Conn 0.6 0.5 1080 1000 GEEK SQUAD RECEPTS. 2011 39 - B - 40 2011 SPARE 20/1 SPARE 1000 . A . 4.3 1080 i GEEK SQUAD RECEPTS. 2011 41 --- 42 20/1 SPARE 20/1 SPARE 1 i 0 0' 0 8720 6840 5560 0 0 0 0 0 0 0 0 0 NONE. NONE NONE Main. - -- . ,._. Breaker ` -A- -13- - C - Through Feed Lug Conn NONE NONE NONE Ei= NONE NONE NONE 0 10320 0 0 11360 400 0 11360 0 -A. 8.7 .B. 6.8 - C - Total . . .. 0.0 15.6 Connected KVA Totals . . I -13- 1 7.3 11 2- I I Bus KVA loads I Lighting -Code L Dmd 0.0 Conn 0.0 Panelboard Notes Conn 0.0 Panelboard Notes: 19.1 IConvenience _ 1 18.4 1 60.0 IConnected KVA Totals Convenience Receptacles (180 W) - Code C 15.6 21.1 I- E.C. TO BALANCE EACH PHASE WITHIN 10% I- E.C. TO BALANCE EACH PHASE WITHIN 10% Panelboard Notes: 4- Receptacles (Non Convenience) - Code R 0.0 I 0.0 2-; 2.1 I : : 2- . . 1 - E.C. TO BALANCE EACH PHASE WITHIN 10% � . 9600,125% Largest Motor 1 Motors - Code M 2.4 0.0 3-i 12.2 12.0 3- II Spare = 0% Spare KVA 0 _ . -- EXISTING , Electric Heat- Code E 0.0 0.0 4- 0.0 i 4- Project Name : IFile Name: Date: 208 : Phase to Phase Voltage Total KVA 18.0 21.1 5 - 19.1 18.9 5- : Amp Rating of Bus Spare =1 0% ; Spare KVA 0 Spare= EXISTING : Mounting 60.0 EXISTINGEPhaseAto'PRhaa"se Project Number: Project Name : Adjusted KVA (Demand+ Spare KVA) 18 40 EXISTING : Amps AIC RatingAdjusted 19 0 EXISTINGng EXISTING : Mounting I BEST BUY-TUKWILA, WA Amps (Demand + Spare KVA) 50 111 100 : Amp Rating of Bus 41 150 f Bus ... Adjusted Amps (Demand + Spare KVA) 100 : Panel Amp Rating (Min Main) : Panel Amp Rating (Min Main) 200 Project Number: Project Name : File Name: I Date: Project Name : 208 : Phase to Phase Voltage. Date: ...... 208 416752-040 200 I BEST BUY-TUKWILA, WA PANEL LA 1 1 21412 01 5 NOTE TO PLAN REVIEWER: PEAK DEMAND READING FOR PREVIOUS 12 MONTHS OF STORE OPERATION. TAKEN FROM OWNER UTILITY BILL JUN 2015 = 204KW 204KW x 1.25 = 255 KW 1307 AMPS PAC SALES= 29KW 307+29 =336 KW! 404 AMPS EXISTING SERVICE IS 1,200 AMPS STORE IS BEING REMODELED AND EXISTING POWER IS BEING REDISTRIBUTED AT SALES FLOOR. OVERALL CONSUMPTION IS REMAINING THE SAME OR BEING REDUCED. 1. THE ELECTRICAL CONTRACTOR SHALL PROVIDE NEW BREAKERS IN EXISTING GEAR AS REQUIRED. CONTRACTOR TO VERIFY ANY EXISTING SERIES RATINGS ARE IN COMPLIANCE. MAINTAIN AS REQUIRED. MATCH MANUFACTURES AND AIC RATINGS. EXISTING (2) 4 #350 & 1#1 GND. EXISTING I Panel: Panel•! LC SERVICE 1200A MCB GFP Voltage: Volta e: 120/208v, 3Ph, 4w Code Code L- VA C- VA Code Code - L VA CVA Code Code Code -VA R M VA E VA Code L- VA Code C- VA Code CodeCode R - VA M - VA E - VA Description Amp / ole No. Ph No. 1 Amp /pole Descri tion Code Code Code L- VA C- VA R - VA Code M - VA Code E - VA 1 800 2 EXISTING COLUMN RECEPTS. 2011 1 . A - 2 1 1511 EXISTING EF -1 2011 900 - B - 4 600 EXISTING FLOOR RECEPT. EXISTING COLUMN RECEPTS. 2011 3 - B - 4 1511 EXISTING EF -2 - C - 900 20/1 EXISTING FLOOR RECEPT. 600 400 EXISTING COLUMN RECEPTS. 20/1 5 -C- 6 20/1 SPARE 2011 EXISTING FLOOR RECEPT. 1000 360 600 TV DISPLAY RECEPTS. EXISTING COLUMN RECEPTS. 2011 7 -A - 8 20/1 SPARE 1000 - B - 360 1 600 20/1 EXISTING COLUMN RECEPTS. 2011 9 1 - B - I 10 2011 1 SPARE 1000 I EXISTING FLOOR RECEPT. 20/1 13 1700 EXISTING WH -1 2011 11 -C- 12 2011 SPARE EXISTING FLOOR RECEPT. 2011 15 -13- 16 200 EXISTING P-2 1511 13 -A- 14 20/1 SPARE 17 - C - 18 20/1 CASHWRAP RECEPTS. 400 EXISTING F/S DAMPER 2011 15 -B- 16 2011 SPARE 20 2011 DISPLAY RECEPTS 1440 EXISTING FLOOR RECEPTS. 360 SPARE 2011 17 -C- 18 20/1 SPARE DISPLAY RECEPTS. 1 540 1000 360 EXISTING FLOOR RECEPTS. GEEK TV RECEPTACLE SPARE 20/1 19 -A- 20 2011 SPARE 360 720 500 DISPLAY RECEPTS 20/1 25 SPARE 2011 21 - B - 22 20/1 EXISTING RTU RECPTS. 1600 DISPLAY RECEPTS. 2011 27 -13- 28 SPARE 20/1 23 -C- 24 2011 EXISTING EXHAUST FANS 20/1 400 - C - 30 2011 APPLIANCE DISPLAY RECEPTS. SPARE 2011 25 -A- 26 2011 SPARE - A - 32 2011 APPLIANCE DISPLAY RECEPTS. 720 1400 SPARE 20/1 27 -13- 28 2011 SPARE 20/1 APPLIANCE DISPLAY RECEPTS. 720 1000 1440 1 SPARE 20/1 29 - C - 30 2011 SPARE 720 33 - B - 1000 SPARE 1600 EXISTING RTU -12 201 31 -A- 32 20/1 SPARE 1000 -C- SPARE 2011 39 1600 " 2 33 - B - 34 2011 SPARE EXISTING EMS SYSTEM 20/1 1 41 - C - 42 1600 EXISTING RTU -13 20/ 35 - C - 36 2011 SPARE - A - - B - - C - Through Feed Lug Conn NONE NONE I NONE 1000 360 1600 - C - Total 11.7 1 34.1 Connected KVA Totals 2 37 -A- 38 1 20/1 SPARE Bus KVA loads Lighting -Code L Dmd Conn 0.6 0.5 Panelboard Notes: 1000 360 1600 EXISTING RTU -14 20/ 39 -13- 40 1 20/1 SPARE 1000 . A . 4.3 - B - 4.1 i 360 1600 1.4 1.4 2 1 41 - C - 42 1 20/1 SPARE 1 i 6900'125% Largest Motor Motors -Code M 0 0 0 1400 2800 600 0 4300 0 1 400 4100 0 1 1 1700 3600 0 1 NONE NONE NONE Main Breaker -A- -B-- -C- Through Feed Lug Conn NONE NONE NONE 0 10320 0 0 11360 400 0 11360 0 0 0 0 Electric Heat - Code E - A - 5.7 I -13- 1 7.3 - C - I Total 1 5.9 1 18.9 Connected KVA Totals 2- I I Bus KVA loads Lighting -Code L Bus KVA loads i Lighting -Code L Dmd 0.0 Conn 0.0 Panelboard Notes: 19.1 IConvenience _ 1 18.4 1 60.0 IConnected KVA Totals Convenience Receptacles (180 W) -Code C 1 Receptacles (180 W) -Code C 4.8 4.8 I- E.C. TO BALANCE EACH PHASE WITHIN 10% Panelboard Notes: 4- (Non Convenience) -Code R Receptacles Convenience ( ) - Code R i Receptacles (Non Convenience) - Code R 2.1 2.1 2- : Amps AIC Rating 1 - E.C. TO BALANCE EACH PHASE WITHIN 10% 11.3 12.6 S. 200125%Largest Motor Motors -CodeM 696 125% Largest Motor Motors -Code M 12.2 12.0 3- II Spare = 0% Spare KVA 0 _ . -- EXISTING : Mounting Electric Heat - Code E Electric Heat - Code E 100 Electric Heat - Code E 0.0 0.0 4- Project Name : IFile Name: Date: 208 : Phase to Phase Voltage Total KVA Total KVA : Total KVA 19.1 18.9 5- : Amp Rating of Bus Spare =! Spare = 0% Spare KVA Spare= 0% Spare KVA 0 60.0 EXISTINGEPhaseAto'PRhaa"se Project Number: Project Name : Fite Name: Adjusted KVA (Demand + Spare KVA) 40 Adjusted KVA (Demand + Spare KVA) 19 0 EXISTINGng EXISTING : Mounting I BEST BUY-TUKWILA, WA PANEL LG Adjusted Amps (Demand + Spare KVA) 111 Adjusted Amps (Demand + Spare KVA) 63 41 150 f Bus Adjusted Amps (Demand + Spare KVA) 115 .... : Panel Amp Rating (Min Main) 200 150 ating (Min Main) Project Name :File Name: Project Number: Project Name : File Name: I 208 Date: ...... 208 se Voltage 200 : Panel Amp Rating (Min Main)Project IBEST BUY-TUKWILA, WA 416752-040 I I BEST BUY-TUKWILA, WA I PANEL LC I 1 12/412015 NOTE TO PLAN REVIEWER: PEAK DEMAND READING FOR PREVIOUS 12 MONTHS OF STORE OPERATION. TAKEN FROM OWNER UTILITY BILL JUN 2015 = 204KW 204KW x 1.25 = 255 KW 1307 AMPS PAC SALES= 29KW 307+29 =336 KW! 404 AMPS EXISTING SERVICE IS 1,200 AMPS STORE IS BEING REMODELED AND EXISTING POWER IS BEING REDISTRIBUTED AT SALES FLOOR. OVERALL CONSUMPTION IS REMAINING THE SAME OR BEING REDUCED. 1. THE ELECTRICAL CONTRACTOR SHALL PROVIDE NEW BREAKERS IN EXISTING GEAR AS REQUIRED. CONTRACTOR TO VERIFY ANY EXISTING SERIES RATINGS ARE IN COMPLIANCE. MAINTAIN AS REQUIRED. MATCH MANUFACTURES AND AIC RATINGS. EXISTING (2) 4 #350 & 1#1 GND. EXISTING I Panel: LH LB SERVICE 1200A MCB GFP Voltage: Volta 120/208v, 3Ph, 4w 120/208v 3Ph 4w x x Code Code L- VA C- VA Code Code - L VA CVA Code Code Code -VA R M VA E VA Description Amp _ /pole No. Ph No. Amp !ole Description Code Code Code L -VA C -VA R -VA Code Code M -VA E -V A 1000I Code Code Code L- Vv -C-VA R -VA EXISTING FLOOR RECEPT. 2011 1 -A- 2 20/1 EXISTING FLOOR RECEPT. 1000 -A- 1000 20/1 EXISTING FLOOR RECEPT. 2011 3 - B - 4 20/1 EXISTING FLOOR RECEPT. 1000 2 1000 - B - EXISTING FLOOR RECEPT. 20/1 5 - C - 6 20/1 EXISTING FLOOR RECEPT. 1000 400 1000 2011 EXISTING FLOOR RECEPT. 20/1 7 - A - 8 2011 EXISTING FLOOR RECEPT. 1000 360 1000 TV DISPLAY RECEPTS. EXISTING FLOOR RECEPT. 2011 9 - B - 10 20/1 EXISTING FLOOR RECEPT. 1000 - B - 360 1 EXISTING SECURITY SHUTTER 20/1 11 - C - 12 20/1 1 APPLIANCE DISPLAY RECEPTS. 720 TV DISPLAY RECEPTS. 1000 I EXISTING FLOOR RECEPT. 20/1 13 - A - 14 20/1 1 APPLIANCE DISPLAY RECEPTS. 1 720 12 1000 I EXISTING FLOOR RECEPT. 2011 15 -13- 16 20/1 CASHWRAP RECEPTS. 1080 13 1000 I EXISTING FLOOR RECEPT. 20/1 17 - C - 18 20/1 CASHWRAP RECEPTS. 720 EXISTING EMP. STATION ISC 360 1 DISPLAY RECEPTS. 2011 19 - A - 20 2011 DISPLAY RECEPTS 1440 EXISTING FLOOR RECEPTS. 360 1 DISPLAY RECEPTS. 20/1 1 21 -13- 22 2011 DISPLAY RECEPTS. 1 540 1000 360 EXISTING FLOOR RECEPTS. GEEK TV RECEPTACLE 20/1 23 - C - 24 J 20/1 VENDING RECEPTS. 1000 360 720 500 DISPLAY RECEPTS 20/1 25 - A - 26 20/1 DISPLAY RECEPTS. 720 20/1 720 DISPLAY RECEPTS. 2011 27 -13- 28 2011 APPLIANCE 01' RPI R9zCFPT3. 720 -C- 720 2011 DISPLAY RECEPTS. 20/1 29 - C - 30 2011 APPLIANCE DISPLAY RECEPTS. 720 1511 720 -A- DISPLAY RECEPTS. 2011 31 - A - 32 2011 APPLIANCE DISPLAY RECEPTS. 720 1400 1440 15/1 PAC SALES DESK 2011 33 - B - 34 20/1 APPLIANCE DISPLAY RECEPTS. 720 1000 1440 1 PAC SALES DESK 2011 1 35 - C - 36 2011 APPLIANCE DISPLAY RECEPTS. 720 33 - B - 1000 SPARE 2011 1 37 A - 38 20/1 APPLIANCE DISPLAY RECEPTS. 720 1 EXISTING FIXTURE RECEPTS. 1000 -C- SPARE 2011 39 - B - 1 40 1 2011 APPLIANCE DISPLAY RECEPTS. 720 34 20/1 1400 EXISTING EMS SYSTEM 20/1 1 41 - C - 42 2011 EXSITING OPEN SIGN 500 35 0 11120 0 11300 500 9760 0 0 0 0 0 0 1400 0 0 NONE NONE NONE Main Breaker - A - - B - - C - Through Feed Lug Conn NONE NONE I NONE 1000 360 - A - - B - 11.1 I 11.3 - C - Total 11.7 1 34.1 Connected KVA Totals 20/1 37 I' ! 2011 EXISTING FIXTURE RECEPTS. Bus KVA loads Lighting -Code L Dmd Conn 0.6 0.5 Panelboard Notes: 1000 360 EXISTING FLOOR RECEPTS. TV DISPLAY RECEPTS. 2011 39 Convenience Receptacles (180 W) -Code C 21.1 32.2 I- E.C. TO BALANCE EACH PHASE WITHIN 10% 1000 . A . 4.3 - B - 4.1 i 360 Receptacles (Non Convenience) - Code R 1.4 1.4 2- 41 - C - 42 2011 EXISTING HOME THEATER WALL WASHER 1 i 6900'125% Largest Motor Motors -Code M 1.7 0.0 3- 600 3400 0 2500 2500 0 2800 0 0 NONE NONE NONE Main Breaker -A- - B - C- Through Feed Lug ... _ Conn ! 0 10320 0 0 11360 400 0 11360 0 0 0 0 Electric Heat - Code E 0.0 0.0 4- I -C- I Total I 2- I I Bus KVA loads Lighting -Code L Dmd 0.8 Total KVA 24.8 1 34.1 5- 19.1 1 22.6 _ 1 18.4 1 60.0 IConnected KVA Totals Convenience Receptacles (180 W) -Code C 1 31.5 Spare = 0% Spare KVA 0 EXISTING : Mounting Panelboard Notes: 4- (Non Convenience) -Code R Receptacles Convenience ( ) - Code R i 6.7 Adjusted KVA (Demand + Spare KVA) 25 EXISTING : Amps AIC Rating 1 - E.C. TO BALANCE EACH PHASE WITHIN 10% 11.3 12.6 S. 200125%Largest Motor Motors -CodeM Adjusted Amps (Demand + Spare KVA) 69 125 : Amp Rating of Bus 2- II Spare = 0% Spare KVA 0 _ . -- EXISTING : Mounting Electric Heat - Code E Electric Heat - Code E 100 : Panel Amp Rating (Min Main) 5.9 5.9 Project Number. Project Name : IFile Name: Date: 208 : Phase to Phase Voltage Total KVA Total KVA : Electric Heat - Code E IBEST BUY-TUKWILA, WA I PANEL LH 12/412015 NOTE TO PLAN REVIEWER: PEAK DEMAND READING FOR PREVIOUS 12 MONTHS OF STORE OPERATION. TAKEN FROM OWNER UTILITY BILL JUN 2015 = 204KW 204KW x 1.25 = 255 KW 1307 AMPS PAC SALES= 29KW 307+29 =336 KW! 404 AMPS EXISTING SERVICE IS 1,200 AMPS STORE IS BEING REMODELED AND EXISTING POWER IS BEING REDISTRIBUTED AT SALES FLOOR. OVERALL CONSUMPTION IS REMAINING THE SAME OR BEING REDUCED. 1. THE ELECTRICAL CONTRACTOR SHALL PROVIDE NEW BREAKERS IN EXISTING GEAR AS REQUIRED. CONTRACTOR TO VERIFY ANY EXISTING SERIES RATINGS ARE IN COMPLIANCE. MAINTAIN AS REQUIRED. MATCH MANUFACTURES AND AIC RATINGS. EXISTING (2) 4 #350 & 1#1 GND. EXISTING I EXISTING Panel: LB SERVICE 1200A MCB GFP EQUIPMENT Volta e: 120/208v 3Ph 4w x x Code Code L- VA C- VA Code Code Code R - VA M - VA E - VA I Code Code L- VA I C- VA C ode L- VA C ode C- VA A C C C ode ode ode _R -VA M -VA E_VA.._.._.......... Descn bon Description Am p _. /ole ..-_. No. Ph . No. Am p ........ !ole ...... ___._,_ Descn Uon Code Code Code L- Vv -C-VA R -VA Code M -VA Code E -VA 360 1 2500 EXSITING AIR COMPRESSOR 30/ 1 -A- 2 1 20/1 1 TV DISPLAY RECEPTS. 360 EXISTING EMP STAT. APPLIANCES 2011 360 - B - 2500 20/1 2 3 - B - 4 20/1 TV DISPLAY RECEPTS. 360 2011 5 360 6 400 EXISTING EXTERIOR DOOR 2011 5 C - 6 20/1 TV DISPLAY RECEPTS. 360 7 A - 360 600 TV DISPLAY RECEPTS. EXISTING ISC WAITING RECEPTS. 2011 7 -A- 8 20/1 TV DISPLAY RECEPTS. 1 360 - B - 10 1000 1400 1 EXISTING ISC RECEPTS. 20/1 9 -13- 10 20/1 TV DISPLAY RECEPTS. 1 360 12 2011 1000 400 200 EXISTING DOOR OPERATOR ISC 20/1 11 - C - 12 20/1 TV DISPLAY RECEPTS. 360 2011 EXISTING COMM RM RECEPTS. 1000 SPARE 200 EXISTING DOOR OPERATOR ISC 20/1 13 - A - 14 2011 TV DISPLAY RECEPTS. 360 EXISTING COMM RM RECEPTS. 400 1000 1000 EXISTING DISPLAY RECEPTS. EXISTING EMP. STATION ISC 20/1 15 -13- 16 2011 TV DISPLAY RECEPTS. 360 400 1000 1000 EXISTING FLOOR RECEPTS. 1500 EXISTING WH -2 20/1 17 - C - 18 2011 TV DISPLAY RECEPTS. 360 - A . 1000 1000 EXISTING FLOOR RECEPTS. 400 EXISTING F/S DAMPER 15/1 19 -A- 20 2011 TV DISPLAY RECEPTS. 360 500 1000 EXISTING MONITOR RECEPTS. 700 EXISTING UH -1 15/1 21 B - 22 20/1 SPARE 500 1000 1000 I 700 EXISTING UH -2 1511 23 -C- 24 2011 SPARE 500 -C- EXISTING MONITOR RECEPTS. 1000 27 900 EXISTING EF -3 1511 25 -A- 26 2011 SPARE EXISTING MONITOR RECEPTS. 2011 1000 - C - 1400 EXISTING EMS 15/1 27 -B- 28 20/1 SPARE EXISTING CASHWRAP RECEPTS. 2011 31 1000 32 EXISTING DISPLAY RECEPTS. SPARE 20/1 29 - C - 30 20/1 EXISTING FIXTURE RECEPTS. 1000 33 - B - 1000 360 EXISTING DISPLAY RECEPTS. TV DISPLAY RECEPTS. 2011 31 -A- 32 20/1 1 EXISTING FIXTURE RECEPTS. 1000 -C- 36 2011 360 SPARE TV DISPLAY RECEPTS. 2011 33 - B - 34 20/1 EXISTING FIXTURE RECEPTS. 1000 38 2011 SPARE 360 SPARE TV DISPLAY RECEPTS. 2011 35 - C - 36 20/1 EXISTING FIXTURE RECEPTS. 1000 20/1 1 SPARE 1000 360 EXISTING FLOOR RECEPTS. TV DISPLAY RECEPTS. 20/1 37 -A- 38 2011 EXISTING FIXTURE RECEPTS. 1000 1 EXISTING PHONE BOARD RECEPT. 400 1000 360 EXISTING FLOOR RECEPTS. TV DISPLAY RECEPTS. 2011 39 -13- 40 20/1 EXISTING FIXTURE RECEPTS. 1000 . A . 4.3 - B - 4.1 400 360 EXISTING EXTERIOR DOOR TV DISPLAY RECEPTS. 20/1 41 - C - 42 2011 EXISTING HOME THEATER WALL WASHER 400 0 0 0. 0 0 600 0 0 400 15080 17560 15160 600 3400 0 2500 2500 0 2800 0 0 NONE NONE NONE Main Breaker -A- - B - C- Through Feed Lug ... _ Conn . LB (CONT.) 0 10320 0 0 11360 400 0 11360 0 0 0 0 0 0 0 -A- -B. I -C- I Total I 2- I KVA loads I Lighting - Code L Bus KVA loads Lighting -Code L Dmd 0.8 Bus KVA loads Dmd Conn 19.1 1 22.6 _ 1 18.4 1 60.0 IConnected KVA Totals Convenience Receptacles (180 W) -Code C Convenience Receptacles (180 W) -Code C 31.5 52.9 1Non Lighting -Code L 0.5 0.4 Panelboard Notes: 4- (Non Convenience) -Code R Receptacles Convenience ( ) - Code R 6.7 6.7 2. Convenience Receptacles (180 W) - Code C 28.9 47.8 1 - E.C. TO BALANCE EACH PHASE WITHIN 10% 11.3 12.6 S. 200125%Largest Motor Motors -CodeM 1.0 Receptacles (Non Convenience) - Code R 5.9 5.9 2- Spare = 0% Spare KVA 0 _ . -- EXISTING : Mounting Electric Heat - Code E Electric Heat - Code E 125% Largest Motor Motors - Code 5.9 5.9 3-. 11 EXISTING : Amps AIC Rating Total KVA Total KVA : Electric Heat - Code E 0.0 0.0 4- : Amp Rating of Bus Spare =! Spare = 0% Spare KVA 0 Total KVA 41.2 60.0 5- Project Number: Project Name : Fite Name: Adjusted KVA (Demand + Spare KVA) 40 208 Spare =j 0% are KVA 0 EXISTING : Mounting I BEST BUY-TUKWILA, WA PANEL LG Adjusted Amps (Demand + Spare KVA) 111 200 Adjusted KVA (Demand + Spare KVA) 41 EXISTING : Amps AIC Rating Adjusted Amps (Demand + Spare KVA) 115 .... : Panel Amp Rating (Min Main) 200 : Amp Rating of Bus Project Number: Project Name :File Name: Date: Date: 208 208 : Phase to Phase Voltage ...... ... . 416762-040 200 : Panel Amp Rating (Min Main)Project IBEST BUY-TUKWILA, WA IPANEL LD I Number: Project Name : IFile Name: Date: 208 : Phase to Phase Voltage 416752-040 I BEST BUY-TUKWILA, WA I PANEL LB12/412015 NOTE TO PLAN REVIEWER: PEAK DEMAND READING FOR PREVIOUS 12 MONTHS OF STORE OPERATION. TAKEN FROM OWNER UTILITY BILL JUN 2015 = 204KW 204KW x 1.25 = 255 KW 1307 AMPS PAC SALES= 29KW 307+29 =336 KW! 404 AMPS EXISTING SERVICE IS 1,200 AMPS STORE IS BEING REMODELED AND EXISTING POWER IS BEING REDISTRIBUTED AT SALES FLOOR. OVERALL CONSUMPTION IS REMAINING THE SAME OR BEING REDUCED. 1. THE ELECTRICAL CONTRACTOR SHALL PROVIDE NEW BREAKERS IN EXISTING GEAR AS REQUIRED. CONTRACTOR TO VERIFY ANY EXISTING SERIES RATINGS ARE IN COMPLIANCE. MAINTAIN AS REQUIRED. MATCH MANUFACTURES AND AIC RATINGS. EXISTING (2) 4 #350 & 1#1 GND. EXISTING I EXISTING Panel: LD SERVICE 1200A MCB GFP EQUIPMENT Volta e: 120/208v, 3Ph, 4w Code Code L- VA C- VA Code Code Code R - VA M - VA E - VA I Code Code L- VA I C- VA Code Code L- VA C- VA Code Code Code R - VA M - VA E - VA Description Amp /pole No. Ph No. mpICode /pole Description Code Code L- VA C- VA R - VA Code M - VA Code E - VA 1000. 360 1 TV DISPLAY RECEPTS. 2011 1 - A - 2 2011 EXISTING SPRINKLER BELL 500 1 1115700 0 0 0 EXISTING EMP STAT. APPLIANCES 2011 360 - B - TV DISPLAY RECEPTS. 20/1 3 - B - 4 20/1 SPARE 200 EXISTING EMP ST. HOME THEATER 2011 5 360 6 TV DISPLAY RECEPTS. 20/1 5 - C - 6 1511 EXISTING UNIT HEATER 3 700 2011 7 A - 360 20/1 TV DISPLAY RECEPTS. 20/1 7 - A - 8 1511 EXISTING UNIT HEATER 4 700 9 - B - 10 1000 EXISTING COMM RM RECEPTS. EXISTING FIXTURE RECEPTS. 2011 9 - B - 10 1511 EXISTING EF -1 11 900 12 2011 1000 400 EXISTING FIXTURE RECEPTS. 20/1 1 11 - C - 12 20/1 EXISTING TEXLON RECEPT 400 14 2011 EXISTING COMM RM RECEPTS. 1000 SPARE EXISTING DISPLAY RECEPTS. 2011 13 1 - A - 14 1 20/1 1 SPARE 16 2011 EXISTING COMM RM RECEPTS. 400 1000 SPARE EXISTING DISPLAY RECEPTS. 20/1 15 - B - 16 2011 SPARE 2011 EXISTING COMM RM RECEPTS. 400 1000 1000 EXISTING FLOOR RECEPTS. EXISTING DISPLAY RECEPTS. 20/1 17 - C - 18 2011 SPARE EXISTING COMM RM RECEPTS. 400400 - A . 1000 1000 EXISTING FLOOR RECEPTS. EXISTING DISPLAY RECEPTS. 20/1 19 - A - 20 20/1 EXISTING RTU RECEPTS. 1200 SPACE 500 1000 EXISTING MONITOR RECEPTS. EXISTING DISPLAY RECEPTS. 20/1 21 - B - 22 2011 EXISTING LIFT TRUCK RECEPT. 400 500 1000 1000 I EXISTING DISPLAY RECEPTS. 2011 23 - C - 24 2011 EXISTING LIFT TRUCK RECEPT. 400 500 -C- EXISTING MONITOR RECEPTS. 1000 27 EXISTING DISPLAY RECEPTS. 20/1 25 - A - 26 20/1 EXISTING RECEIVING RECEPTS. 200 EXISTING MONITOR RECEPTS. 2011 1000 - C - EXISTING DISPLAY RECEPTS. 2011 27 -13- 28 20/1 EXISTING RECEIVING RECEPTS. 200 EXISTING CASHWRAP RECEPTS. 2011 31 1000 32 EXISTING DISPLAY RECEPTS. 20/1 29 - C - 30 20/1 EXISTING RECEIVING RECEPTS. 400 2011 33 - B - 1000 20/1 EXISTING DISPLAY RECEPTS. 20/1 31 - A - 32 2011 EXISTING RECEIVING RECEPTS. 200 35 -C- 36 2011 EXISTING RECEIVING RECEPTS. SPARE 20/1 33 - B - 34 2011 EXISTING EXTERIOR DOOR 400 -A- 38 2011 SPARE EXISTING FLOOR RECEPTS . SPARE 2011 35 - C - 36 20/1 EXISTING PIT LEVELERS 600 40 20/1 1 SPARE 1000 EXISTING FLOOR RECEPTS. EXISTING FLOOR RECEPTS. 2011 37 - A - 38 2011 EXISTING DOOR OPERATOR RECEIV. 200 2011 1 EXISTING PHONE BOARD RECEPT. 400 1000 I EXISTING FLOOR RECEPTS. 2011 39 - B - 40 20/1 EXISTING DOOR OPERATOR RECEIV. 200 I . A . 4.3 - B - 4.1 400 1 EXISTING EXTERIOR DOOR 1 2011 41 - C - 42 2011 EXISTING DOCK LIGHT RECEPTS. 600 File Name: 0 0 0. 0 0 600 18160 17080 17680 3000 0 0 1 1200 900 0 2500 0 0 NONE NONE NONE Main Breaker. . - A- - B - - C - Through Feed Lug Conn - LD (CONT.) I - 0 12440 0 0 11720 0 0 12920 0 0 0 0 0 0 0 - A - 21.2 - B - 19.2 - C - Total I 20.8 61.1 Connected KVA Totals Convenience) - Code R 0.0 0.0 2- I KVA loads I Lighting - Code L Bus KVA loads Lighting -Code L Dmd 0.8 Conn 0.6 Panelboard Notes: Motors - Code 0.0 0.0 3- Convenience Receptacles (180 W) -Code C Convenience Receptacles (180 W) -Code C 31.5 52.9 1Non E.C. TO BALANCE EACH PHASE WITHIN 10% Electric Heat - Code E 0.0 0.0 4- (Non Convenience) -Code R Receptacles Convenience ( ) - Code R 6.7 6.7 2. 1 Total KVA 11.3 12.6 S. 200125%Largest Motor Motors -CodeM 1.0 0.9 3- Spare = 0% Spare KVA 0 _ . -- EXISTING : Mounting Electric Heat - Code E Electric Heat - Code E 0.0 0.0 4- Adjusted KVA (Demand +Spare KVA) 11 EXISTING : Amps AIC Rating Total KVA Total KVA 39.9 61.1 5- I 60 : Amp Rating of Bus Spare =! Spare = 0% Spare KVA 0 EXISTING EXISTING : Mounting : Panel Amp Rating (Min Main) Project Number: Project Name : Fite Name: Adjusted KVA (Demand + Spare KVA) 40 208 EXISTING : Amps AIC Rating 416752-040 I BEST BUY-TUKWILA, WA PANEL LG Adjusted Amps (Demand + Spare KVA) 111 200 200 : Amp Rating of Bus 200 200 : Panel Amp Rating (Min Main) Project Number. Project Number: Project Name :File Name: Date: Date: 208 208 : Phase to Phase Voltage 416762-040 416752-040 IBEST BUY-TUKWILA, WA IBEST BUY-TUKWILA, WA IPANEL LD I 12/412015 NOTE TO PLAN REVIEWER: PEAK DEMAND READING FOR PREVIOUS 12 MONTHS OF STORE OPERATION. TAKEN FROM OWNER UTILITY BILL JUN 2015 = 204KW 204KW x 1.25 = 255 KW 1307 AMPS PAC SALES= 29KW 307+29 =336 KW! 404 AMPS EXISTING SERVICE IS 1,200 AMPS STORE IS BEING REMODELED AND EXISTING POWER IS BEING REDISTRIBUTED AT SALES FLOOR. OVERALL CONSUMPTION IS REMAINING THE SAME OR BEING REDUCED. 1. THE ELECTRICAL CONTRACTOR SHALL PROVIDE NEW BREAKERS IN EXISTING GEAR AS REQUIRED. CONTRACTOR TO VERIFY ANY EXISTING SERIES RATINGS ARE IN COMPLIANCE. MAINTAIN AS REQUIRED. MATCH MANUFACTURES AND AIC RATINGS. EXISTING (2) 4 #350 & 1#1 GND. EXISTING I EXISTING Panel: LG SERVICE 1200A MCB GFP EQUIPMENT Volta e: 120/208v, 3Ph, 4w Code Code L- VA C- VA Code Code Code R - VA M - VA E - VA I Code Code L- VA I C- VA Code Code Code R - VA M - VA E - VA 1 Description Amp /pole No. Ph No. Amp /pole Description Code Code Code L- VA C- VA R - VA Code Code M - VA E - VA Code E - VA 200 1000. EXISTING EMP ST. STERIO INSTALL 20/1 1 -A- 2 2011 EXISTING SECURITY RM RECEPTS. 400 LAY C TV DISPLAY RECEPTS. --360. 200 1 1115700 0 0 0 EXISTING EMP STAT. APPLIANCES 2011 3 - B - 4 20/1 EXISTING SECURITY RM RECEPTS. 400 20/1 TV DISPLAY RECEPTS. 200 200 EXISTING EMP ST. HOME THEATER 2011 5 - C - 6 20/1 EXISTING COMM RM RECEPTS. 400 48 20/1 20 0 360 EXISTING EMP ST. HOME ACCESS. 2011 7 A - 8 20/1 EXISTING COMM RM RECEPTS. 40 0 - A - 60 200 TV DISPLAY RECEPTS. EXISTING EMP ST. HOME ACCESS. 2011 9 - B - 10 2011 EXISTING COMM RM RECEPTS. 400 51 -B- 200 2011 EXISTING EMP STATIO2UPGRADE 2011 11 -C- 12 2011 EXISTING COMM RM RECEPTS. 400 20/1 1 53 200 64 EXISTING EMP STATI2011 EXISTING DISPLAY RECEPTS. 13 -A- 14 2011 EXISTING COMM RM RECEPTS. 400 SPARE 2011 200 A - EXISTING SALES DE2011 20/1 15 -B- 16 2011 EXISTING COMM RM RECEPTS. 400 ) SPARE 200 57 EXISTING SALES DE2011 58' 17 -C- 18 2011 EXISTING COMM RM RECEPTS. 400 1000 - B - - C - EXISTING FLOOR RECEPTS. 201 SPARE2011 - C - 19 -A- 20 2011 EXISTING COMM RM RECEPTS. 400400 - A . 1000 I EXISTING FLOOR RECEPTS. EXISTING FIXTURE2011 61 21 - B - 22 2011 SPARE NO SPACE SPACE 500 1 1DISPLAY EXISTING MONITOR RECEPTS. 2011 23 - C - 24 2011 SPARE 1000 500 1000 EXISTING MONITOR RECEPTS. 20/1 25 - A - 26 20/1 EXISTING CUST SERV RECEPTS. 400 1000 500 -C- EXISTING MONITOR RECEPTS. 2011 27 - B - 28 2011 EXISTING CUST SERV RECEPTS. 400 SPARE 1005- 500I EXISTING MONITOR RECEPTS. 2011 29 - C - 30 20/1 EXISTING CUST SERV RECEPTS. 400 2011 EXISTING FIXTURE RECEPTS. 400 Convenience Receptacles (180 W) - Code C EXISTING CASHWRAP RECEPTS. 2011 31 -A- 32 2011 EXISTING CUST SERV RECEPTS. 400 72 20/1 400 1 EXISTING CASHWRAP RECEPTS. 2011 33 - B - 1 34 20/1 EXISTING RECEIVING RECEPTS. 200 - A - 74 400 EXISTING FIXTURE RECEPTS. EXISTING CASHWRAP RECEPTS. 2011 35 -C- 36 2011 EXISTING RECEIVING RECEPTS. 200 . 75. -13- 400 2011 EXISTING CASHWRAP RECEPTS. 2011 37 -A- 38 2011 SPARE EXISTING FLOOR RECEPTS . 2 0 /1 7 7 400 7 8 EXISTING CASHWRAP RECEPTS. 2011 39 - B - 40 20/1 1 SPARE 1 EXISTING FLOOR RECEPTS. 20/1 79 -A- SPARE 2011 41 - C - 42 2011 1 EXISTING PHONE BOARD RECEPT. 400 400 � 0 0 0 4300 4100 4200 0 0 1 0 0 0 0 0 0 0 NONE 1 NONE 1 NONE Main Breaker -A- -13- -C- Through Feed Lug 1NONE I Con INONE I NONE I I I El I . A . 4.3 - B - 4.1 C - Total 4.2 12.6 Connected KVA Totals SPARE 20/1 83 - C - 84 12011 2011 Bus KVA loads Lighting -Code L Dmd Conn 0.0 0.0 Panelboard Notes: File Name: 0 0 0. 10320 11360 11360 0 0 0 400 0 0 0 0 0 I NONE NONE Main Breaker .. Convenience Receptacles (180 W) - Code C 11.3 12.6 I- 1E.C. TO BALANCE EACH PHASE WITHIN 10/, i -A- 10.3 B - 11:8 C - TotalBus .. .. 11.4 33.4 Connected KVA Totals Receptacles (Non Convenience) - Code R 0.0 0.0 2- IPROVIDE ISOLATED GROUND BUS KVA loads I Lighting - Code L Dmd 0.0 Conn 0.0 '125% Largest Motor Motors - Code 0.0 0.0 3- Convenience Receptacles (180 W) -Code C 21.5 33.0 1 - E.C. TO BALANCE EACH PHASE WITHIN 10%Receptacles Electric Heat - Code E 0.0 0.0 4- (Non Convenience) -Code R 0.4 0.4 2-3840:125%Largest Total KVA 11.3 12.6 S. I 1.0 0.0 . Spare = 0% Spare KVA 0 _ . -- EXISTING : Mounting Electric Heat - Code E 0.0 0.0 4- Adjusted KVA (Demand +Spare KVA) 11 EXISTING : Amps AIC Rating Total KVA 22.9 33.4 Adjusted Amps (Demand + Spare KVA) 31 60 : Amp Rating of Bus Spare =! 0% Spare KVA 0 EXISTING : Mounting IAdjusted 125 : Panel Amp Rating (Min Main) Project Number: Project Name : Fite Name: Date: 208 : Phase to Phase Voltage 416752-040 I BEST BUY-TUKWILA, WA PANEL LG 12/4/2015 NOTE TO PLAN REVIEWER: PEAK DEMAND READING FOR PREVIOUS 12 MONTHS OF STORE OPERATION. TAKEN FROM OWNER UTILITY BILL JUN 2015 = 204KW 204KW x 1.25 = 255 KW 1307 AMPS PAC SALES= 29KW 307+29 =336 KW! 404 AMPS EXISTING SERVICE IS 1,200 AMPS STORE IS BEING REMODELED AND EXISTING POWER IS BEING REDISTRIBUTED AT SALES FLOOR. OVERALL CONSUMPTION IS REMAINING THE SAME OR BEING REDUCED. 1. THE ELECTRICAL CONTRACTOR SHALL PROVIDE NEW BREAKERS IN EXISTING GEAR AS REQUIRED. CONTRACTOR TO VERIFY ANY EXISTING SERIES RATINGS ARE IN COMPLIANCE. MAINTAIN AS REQUIRED. MATCH MANUFACTURES AND AIC RATINGS. EXISTING (2) 4 #350 & 1#1 GND. EXISTING I EXISTING UTILITY MDP SERVICE 1200A MCB GFP EQUIPMENT 480/277V, 3PH, 4W, A MLO HD HD CONT, EXISTING 4#310&1#6GND. HA EXISTING 3"C, STING ISTING EXISTING XISTING EXISTING4 #500 KCMIL A MLO LD 25A MLO LB 400A & 1 #110 GND. LD CONT. LB CONT. MCB DP1 12.5 A XFMR REVIEWED.FOR COaPLIANCE WITH NFPA 70 - NEC JAI 13 2016 City of-Tukvuila BUILDING DIVISION SALES DEV. RM 114 r- - - - - - - - - - - - - - - - - - - - 1 EXISTING EXISTING EXISTING 5A MLO 125A MLO 1 OOA MLO LF LG LH EXISTING 3"C, EXISTING 3"C, L - - - - - - - - - J 4 #250 KCMIL `�, 41 #11 KCMIL EXISTING 4 #3 & 1 #4 GND. EXISTING ��ISOLATED EXISTING 1-114"C, EXISTING 2"C, & 1 #110 GND. & 1#8IGN �, I 314"C, 3#8 & 4 #3 & 1 #8 4#1 & 1 #6 1#8 GND. GND. STING EXISTING EXISTING A MLO 50A ML I 30A 60AIF 25A MC HB LC DISC DISC LE I 25AIF 6OAIF EXISTING EXISTING EXISTING 12.5 KV 15 KVA 75 KVA XFMR XFMR XFMR EXISTING 2-112"C T9 FXISTING WIRFWAY . TIA Td 4 #410 & 1 #2 I II I' EXISTING 2"C, 3 #210 & 1#6 GND. L I 2"C 4 #310 1 1 EXISTING I ' EXISTING 4 #110 I ' EXISTING 4 #310 & 1 #6 GND. L--------- ��-----------J i &1#6 GND./ I TC,3#2I0 ( &1#6 GND. EXISTING VC, - -I- - J & 1#6 GND.J I EXISTING 1"C, 3#8 I I 4 #6 & 1 D I I J - J - ----- - - - - I & 1#10 GND. I ISOLATED GND. I I IL - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - EXISTING 0 � I I �------r-----------------�------J � --- I---------------- UTILITYXFMR I EXISTING 1-112"C, EXISTING #8 GND. EXISTING #2 GND. I � EXISTING #110 GND. �� EXISTING #110 GND. �- �- L PER N.E.C. l PER N.E.C. 3#1 & 1#6 GND. 1 PER N.E.C. ---L= PER N.E.C. - EXISTING #310 - I - - INSULATED PER N.E.C. I I I I RECEIVED I ELECTRICAL ROOM 109 1 ELECTRICAL ROOM 104 CITY OF TUKWILA SERVICE RISER DIAGRAM PERMIT CENTER NO SCALE 2 4 I I 11 913O Panel: Panel•'.. LB CONT. c Volta e: Volta e: 120/208v, 3Ph, 4w mN I`n�v z z,-.�, E Code Code L- VA C- VA Code Code Code R - VA M - VA E - VA I Code Code L- VA C- VA Code Code Code R - VA �M - VA E - VA .._. __. _. Description tion Amp% /ole No. Ph No. Amp 1. e .... ... . Desai tion Code Code Code L- VA C- VA R - VA .Code M - VA Code E - VA EXISTING "T1" VIA DP1 1000. 1 EXISTING FLOOR RECEPTS. S G 2011 43 -A 44 201 1 LAY C TV DISPLAY RECEPTS. --360. -B- -C- 1 1115700 0 0 0 0 1000 3 17800 0 0 0 EXISTING FLOOR RECEPTS. 20/1 45 - B - 46 20/1 TV DISPLAY RECEPTS. 360. 200 EXISTING PANEL "HB" 17500 0 0 1000 0 EXISTING FLOOR RECEPTS. 20/1 47 - C - 48 20/1 TV DISPLAY RECEPTS. 360 0 0 0 EXISTING XFMR "T3" 1 30 1000 1 EXISTING FLOOR RECEPTS: 2011 49 - A - 60 2011 TV DISPLAY RECEPTS. 360 / " 1200 0 0 0 0 0 4200 0 0 0 3 1000 0 EXISTING FLOOR RECEPTS. 2011 51 -B- 52 2011 EXISTING DISPLAY RECEPTS. 1000 EXISTING PANEL "HD" 0 0 0 75800 1000 1400 20840 1 200 0 0 i " / EXISTING FLOOR RECEPTS.. 20/1 1 53 1 - C - 64 20/1 1 EXISTING DISPLAY RECEPTS. 1000 EXISTING SURGE PROTECTOR 30 9 720 10 SPARE 2011 55 A - 56 20/1 EXISTING EMP: STATION ISC 600 1.3 SPACE 720 ) SPARE 2011 57 - B - 58' 2011 EXISTING DISPLAY RECEPTS. 1000 1000 - B - - C - EXISTING FLOOR RECEPTS. 201 59 - C - 60 2011 EXISTING DISPLAY' RECEPTS. 1000 13 - A . 1000 I EXISTING FLOOR RECEPTS. 20/1 61 - A - 62 2011 EXISTING DISPLAY RECEPTS. 1000 NO SPACE SPACE 1000 1 1DISPLAY EXISTING FLOOR RECEPTS. 20/1 63 - B - 64 20/1 EXISTING DISPLAY RECEPTS. 1000 NONE 1000 - B - EXISTING FLOOR RECEPTS. 2011 65 -C- 66 20/1 SPARE 1000 I -C- 1000 I EXISTING FLOOR RECEPTS. 20/1 67 - A - 68 2011 SPARE 1005- KVA loads 1000 Conn EXISTING FLOOR RECEPTS. 20/1 1 69 - B - 70 2011 EXISTING FIXTURE RECEPTS. 1000 Convenience Receptacles (180 W) - Code C 104.9 0.0 1000 I EXISTING FLOOR RECEPTS. 20/1 71 - C - 72 20/1 EXISTING FIXTURE RECEPTS. 1000 1 1000 0 125% Largest Motor EXISTING FLOOR RECEPTS. 20/1 73 - A - 74 2011 EXISTING FIXTURE RECEPTS. 1000 1000 0.0 EXISTING FLOOR RECEPTS. 2011 . 75. -13- 76 2011 EXISTING FIXTURE RECEPTS. 1000 Total KVA 516.9 1000 5- EXISTING FLOOR RECEPTS . 2 0 /1 7 7 - C - 7 8 20/1 EXISTING FIXTURE RECEPTS. 1000 0 1000 1 EXISTING FLOOR RECEPTS. 20/1 79 -A- 80 20/1 EXISTING FIXTURE RECEPTS. 1000. : Amps AIC Rating 1200 400 � EXISTING EXTERIORDOO R 20/1 81 - B - 8 2 20/1 EXISTING FIXTURE RECEPTS. 1000 1200 1 SPARE 20/1 83 - C - 84 12011 2011 EXISTING FIXTURE RECEPTS. I I 1000 Project Name : File Name: 0 0 0. 10320 11360 11360 0 0 0 400 0 0 0 0 0 I NONE NONE Main Breaker .. -A- -B -C- Through Feed Lug . Conn. NONE NONE NONE I I PANEL MDP -A- 10.3 B - 11:8 C - TotalBus .. .. 11.4 33.4 Connected KVA Totals :.. . ------ -- KVA loads I Lighting - Code L Dmd 0.0 Conn 0.0 Panelboard Notes: Convenience Receptacles (180 W) -Code C 21.5 33.0 1 - E.C. TO BALANCE EACH PHASE WITHIN 10%Receptacles (Non Convenience) -Code R 0.4 0.4 2-3840:125%Largest Motor Motors-CodeM 1.0 0.0 3-. ; Electric Heat - Code E 0.0 0.0 4- Total KVA 22.9 33.4 5 - Spare =! 0% Spare KVA 0 EXISTING : Mounting IAdjusted KVA (Demand + Spare KVA) 23 EXISTING : Amps AIC Rating Adjusted Amps (Demand+ Spare KVA) 64 200 : Amp Rating of Bus 200 : Panel Amp Rating (Min Main) Project Number. Project Name : File Name: Date: 208 : Phase to Phase Voltage 416762-040 IBEST BUY-TUKWILA, WA PANEL LB (CONTINUED) 1 21412 01 5 EXISTING 3"C, STING ISTING EXISTING XISTING EXISTING4 #500 KCMIL A MLO LD 25A MLO LB 400A & 1 #110 GND. LD CONT. LB CONT. MCB DP1 12.5 A XFMR REVIEWED.FOR COaPLIANCE WITH NFPA 70 - NEC JAI 13 2016 City of-Tukvuila BUILDING DIVISION SALES DEV. RM 114 r- - - - - - - - - - - - - - - - - - - - 1 EXISTING EXISTING EXISTING 5A MLO 125A MLO 1 OOA MLO LF LG LH EXISTING 3"C, EXISTING 3"C, L - - - - - - - - - J 4 #250 KCMIL `�, 41 #11 KCMIL EXISTING 4 #3 & 1 #4 GND. EXISTING ��ISOLATED EXISTING 1-114"C, EXISTING 2"C, & 1 #110 GND. & 1#8IGN �, I 314"C, 3#8 & 4 #3 & 1 #8 4#1 & 1 #6 1#8 GND. GND. STING EXISTING EXISTING A MLO 50A ML I 30A 60AIF 25A MC HB LC DISC DISC LE I 25AIF 6OAIF EXISTING EXISTING EXISTING 12.5 KV 15 KVA 75 KVA XFMR XFMR XFMR EXISTING 2-112"C T9 FXISTING WIRFWAY . TIA Td 4 #410 & 1 #2 I II I' EXISTING 2"C, 3 #210 & 1#6 GND. L I 2"C 4 #310 1 1 EXISTING I ' EXISTING 4 #110 I ' EXISTING 4 #310 & 1 #6 GND. L--------- ��-----------J i &1#6 GND./ I TC,3#2I0 ( &1#6 GND. EXISTING VC, - -I- - J & 1#6 GND.J I EXISTING 1"C, 3#8 I I 4 #6 & 1 D I I J - J - ----- - - - - I & 1#10 GND. I ISOLATED GND. I I IL - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - EXISTING 0 � I I �------r-----------------�------J � --- I---------------- UTILITYXFMR I EXISTING 1-112"C, EXISTING #8 GND. EXISTING #2 GND. I � EXISTING #110 GND. �� EXISTING #110 GND. �- �- L PER N.E.C. l PER N.E.C. 3#1 & 1#6 GND. 1 PER N.E.C. ---L= PER N.E.C. - EXISTING #310 - I - - INSULATED PER N.E.C. I I I I RECEIVED I ELECTRICAL ROOM 109 1 ELECTRICAL ROOM 104 CITY OF TUKWILA SERVICE RISER DIAGRAM PERMIT CENTER NO SCALE 2 4 I I 11 913O Panel: Panel: LD CONT. c Volta e: Voltage: ill 120/208v, 3Ph, 4w mN I`n�v z z,-.�, E Code Code L- VA C- VA Code Code Code R - VA M - VA E - VA I Code Code L- VA C- VA Code Code Code R - VA M - VA E - VA Description Amp /pole I No. Ph No. I AmpCode f ole Description i Code Code L- VA C- VA R - VA Code M - VA Code E - VA EXISTING "T1" VIA DP1 720 1 DISPLAY RECEPTS. 2011 43 - A - 44 2011 DISPLAY RECEPTS. 720 -B- -C- 1 1115700 0 0 0 0 720 3 17800 0 0 0 DISPLAY RECEPTS. 2011 45 - B - 46 2011 DISPLAY RECEPTS. 720 200 EXISTING PANEL "HB" 17500 0 0 720 0 DISPLAY RECEPTS. 2011 47 - C - 48 20/1 EXISTING FIXTURE RECEPTS, 1000 0 0 0 EXISTING XFMR "T3" 1 30 720 1 DISPLAY RECEPTS. 20/1 49 -A- 50 2011 EXISTING FIXTURE RECEPTS. 1000 / " 1200 0 0 0 0 0 4200 0 0 0 3 720 0 DISPLAY RECEPTS. 2011 51 - B - 52 2011 EXISTING FIXTURE RECEPTS. 1000 EXISTING PANEL "HD" 0 0 0 75800 720 1400 20840 1 200 0 0 i " / DISPLAY RECEPTS. 2011 53 -C - 54 2011 EXISTING FIXTURE RECEPTS. 1000 EXISTING SURGE PROTECTOR 30 9 720 10 DISPLAY RECEPTS. 2011 55 - A - 56 2011 EXISTING FLOOR RECEPTS. 1000 1.3 SPACE 720 DISPLAY RECEPTS. 2011 57 - B - 58 2011 EXISTING FLOOR RECEPTS. 1000 720 - B - - C - DISPLAY RECEPTS. 2011 59 -C - 60 2011 EXISTING FLOOR RECEPTS. 1000 13 - A . 720 - DISPLAY RECEPTS. 2011 61 -A - 62 2011 EXISTING FLOOR RECEPTS. 1000 NO SPACE SPACE 720 1 1DISPLAY RECEPTS. 2011 63 - B - 64 1511 EXISTING FLOOR RECEPTS. 1000 NONE 720 - B - DISPLAY RECEPTS. 201165 - C - 66 2011 EXISTING FLOOR RECEPTS. 1000 I -C- 720 NONE DISPLAY RECEPTS. 20/1 j 67 -A - 68 2011 EXISTING FLOOR RECEPTS. 1005- KVA loads 720 Conn DISPLAY RECEPTS. 20/1 69 - B - 70 20/1 EXISTING FLOOR RECEPTS. 1000 Convenience Receptacles (180 W) - Code C 104.9 0.0 720 DISPLAY RECEPTS. 2011 71 - C - 72 2011 EXISTING FLOOR RECEPTS. 1000 1 720 0 125% Largest Motor DISPLAY RECEPTS. 2011 73 A • 74 2011 EXISTING FLOOR RECEPTS. 1000 Electric Heat - Code E 0.0 SPARE 2011 75 _-B. 76 2011 EXISTING FLOOR RECEPTS.- 1000 Total KVA 516.9 720 5- DISPLAY RECEPTS. 2011 77 - C . 78 2011 EXISTING ACCESSARY RECEPTS. 1200 0 1200 1 1 EXISTING ACCESSARY RECEPTS. 2011 79 - A - 80 12011 (Demand + Spare KVA) EXISTING ACCESSARY RECEPTS. 1200 : Amps AIC Rating 1200 1 1 EXISTING ACCESSARY RECEPTS. 2011 81 -8. 82 2011 EXISTING ACCESSARY RECEPTS. 1200 1200 1 EXISTING ACCESSARY RECEPTS. 2011 1 83 - C - 84 2011 EXISTING ACCESSARY RECEPTS. 1200 Project Name : File Name: 0 0 0 12440 11720 12920 0 0 0 1 0 0 0 1 0 0 0 I NONE NONE NONE Main Breaker -A- -B- -C- Through Feed Lug Conn NONE NONE NONE IBEST BUY-TUKWILA, WA I PANEL MDP - A - 12.4 I - B - 1 11.7 - C - Total.. _.._..._.---.... _ __ _ .__.._.__. 1 12.9 37.1 Connected KVA Totals .._..---- ------ -- Lighting -Code L 0.0 0.0 Panelboard Notes Convenience Receptacles (180 W) - Code C 23.5 37.1 1 - E.C. TO BALANCE EACH PHASE WITHIN 10% Receptacles (Non Convenience) - Code R 0.0 0.0 2- 3846125% Largest Motor Motors - CodeM 1.0 0.0 3- Electric Heat - Code E 0.0 0.0 4- Total KVA 24.5 37.1 5- Spare =. 0% 7 Spare KVA 0 EXISTING : Mounting Adjusted KVA (Demand + Spare KVA) 25 EXISTING : Amps AIC Rating Adjusted Amps (Demand + Spare KVA) 68 200 :Amp Rating of Bus 200 :Panel Amp Rating (Min Main) ro" ect Number: P 1 Project Name : File Name: Date: 208 : Phase to Phase Voltage 416752-040 I BEST BUY-TUKWILA, WA PANEL LD (CONTINUED) 121412015 EXISTING 3"C, STING ISTING EXISTING XISTING EXISTING4 #500 KCMIL A MLO LD 25A MLO LB 400A & 1 #110 GND. LD CONT. LB CONT. MCB DP1 12.5 A XFMR REVIEWED.FOR COaPLIANCE WITH NFPA 70 - NEC JAI 13 2016 City of-Tukvuila BUILDING DIVISION SALES DEV. RM 114 r- - - - - - - - - - - - - - - - - - - - 1 EXISTING EXISTING EXISTING 5A MLO 125A MLO 1 OOA MLO LF LG LH EXISTING 3"C, EXISTING 3"C, L - - - - - - - - - J 4 #250 KCMIL `�, 41 #11 KCMIL EXISTING 4 #3 & 1 #4 GND. EXISTING ��ISOLATED EXISTING 1-114"C, EXISTING 2"C, & 1 #110 GND. & 1#8IGN �, I 314"C, 3#8 & 4 #3 & 1 #8 4#1 & 1 #6 1#8 GND. GND. STING EXISTING EXISTING A MLO 50A ML I 30A 60AIF 25A MC HB LC DISC DISC LE I 25AIF 6OAIF EXISTING EXISTING EXISTING 12.5 KV 15 KVA 75 KVA XFMR XFMR XFMR EXISTING 2-112"C T9 FXISTING WIRFWAY . TIA Td 4 #410 & 1 #2 I II I' EXISTING 2"C, 3 #210 & 1#6 GND. L I 2"C 4 #310 1 1 EXISTING I ' EXISTING 4 #110 I ' EXISTING 4 #310 & 1 #6 GND. L--------- ��-----------J i &1#6 GND./ I TC,3#2I0 ( &1#6 GND. EXISTING VC, - -I- - J & 1#6 GND.J I EXISTING 1"C, 3#8 I I 4 #6 & 1 D I I J - J - ----- - - - - I & 1#10 GND. I ISOLATED GND. I I IL - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - EXISTING 0 � I I �------r-----------------�------J � --- I---------------- UTILITYXFMR I EXISTING 1-112"C, EXISTING #8 GND. EXISTING #2 GND. I � EXISTING #110 GND. �� EXISTING #110 GND. �- �- L PER N.E.C. l PER N.E.C. 3#1 & 1#6 GND. 1 PER N.E.C. ---L= PER N.E.C. - EXISTING #310 - I - - INSULATED PER N.E.C. I I I I RECEIVED I ELECTRICAL ROOM 109 1 ELECTRICAL ROOM 104 CITY OF TUKWILA SERVICE RISER DIAGRAM PERMIT CENTER NO SCALE 2 4 I I 11 913O Panel: MDP ; c Volta e: 277/480v, 3Ph, 4w ill a mN I`n�v z z,-.�, E Code Code L- VA C- VA Code Code Code R - VA M - VA E - VA I Description Amp /pole No. Ph No. Amp /pole Description Code Code Code L- VA C- VA R - VA Code M . VA Code E - VA 0 33240 3600 3400 0 EXISTING "T1" VIA DP1 175 1 A 2 200 EXISTING PANEL "HA" 16600 0 0 0 0 0 34640 3700 3400 0 " / -B- -C- 1 1115700 0 0 0 0 1000 32840 5300 0 0 1.3 3 17800 0 0 0 0 0 15380 9780 4300 0 EXISTING "72" VIA DP2 175 3 - A - 4 200 EXISTING PANEL "HB" 17500 0 0 0 0 0 1 17100 6540 4300 0 1. , / -B- I -C- / 1. 12400 0 0 0 i 0 0 1 12680 8540 3600 0 3 3 15600 0 1 0 0 0 0 1 4300 0 0 0 EXISTING XFMR "T3" 1 30 5 -A- 6 200 EXISTING PANEL "HC" I 0 0 0 0 0 0 1 4100 0 0 0 1./ -B- C- / " 1200 0 0 0 0 0 4200 0 0 0 3 3 1200 0 0 0 0 0 1000 200 0 0 EXISTING XFMR "74" 125 7 - A - 8 600 EXISTING PANEL "HD" 0 0 0 75800 0 1400 20840 1 200 0 0 i " / -B. .C. / 1. 0 0 0 76800 0 500 19480 1600 0 0 113 3 0 0 0 75800 0 EXISTING SURGE PROTECTOR 30 9 -A - 10 - SPACE " / :B - C- . SPACE 1.3 SPACE NO SPACE - 11 . A - 12 - SPACE NO SPACE - B - - C - - SPACE NO SPACE SPACE NO SPACE 13 - A . 14 - SPACE NO SPACE - B- -C- SPACE NO SPACE SPACE NONE Main - A - Through NONE NONE Breaker - B - Feed Lug NONE NONEI I -C- Conn NONE -A- -13- 0.0 0.0 -C- Total 0.0 0.0 Connected KVA Totals ! Bus KVA loads Dmd Conn Lighting -Code L 126.1 0.0 Panelboard Notes: ! Convenience Receptacles (180 W) - Code C 104.9 0.0 I- E.C. TO BALANCE EACH PHASE WITHIN 10% ; Receptacles (Non Convenience) - Code R 39.5 0.0 2- 1 0 125% Largest Motor Motors - Code W' 246.4 0.0 3- I. Electric Heat - Code E 0.0 0.0 4- I I Total KVA 516.9 0.0 5- ! Spare = 0% Spare KVA 0 : Mounting I Adjusted KVA (Demand + Spare KVA) 517 : Amps AIC Rating i Adjusted Amps (Demand + Spare KVA) 622 M�2O : Amp Rating of Bus : Panel Amp Rating (Min Main) Project Number: Project Name : File Name: Date: : Phase to Phase Voltage IBEST BUY-TUKWILA, WA I PANEL MDP 12/4/2015 EXISTING 3"C, STING ISTING EXISTING XISTING EXISTING4 #500 KCMIL A MLO LD 25A MLO LB 400A & 1 #110 GND. LD CONT. LB CONT. MCB DP1 12.5 A XFMR REVIEWED.FOR COaPLIANCE WITH NFPA 70 - NEC JAI 13 2016 City of-Tukvuila BUILDING DIVISION SALES DEV. RM 114 r- - - - - - - - - - - - - - - - - - - - 1 EXISTING EXISTING EXISTING 5A MLO 125A MLO 1 OOA MLO LF LG LH EXISTING 3"C, EXISTING 3"C, L - - - - - - - - - J 4 #250 KCMIL `�, 41 #11 KCMIL EXISTING 4 #3 & 1 #4 GND. EXISTING ��ISOLATED EXISTING 1-114"C, EXISTING 2"C, & 1 #110 GND. & 1#8IGN �, I 314"C, 3#8 & 4 #3 & 1 #8 4#1 & 1 #6 1#8 GND. GND. STING EXISTING EXISTING A MLO 50A ML I 30A 60AIF 25A MC HB LC DISC DISC LE I 25AIF 6OAIF EXISTING EXISTING EXISTING 12.5 KV 15 KVA 75 KVA XFMR XFMR XFMR EXISTING 2-112"C T9 FXISTING WIRFWAY . TIA Td 4 #410 & 1 #2 I II I' EXISTING 2"C, 3 #210 & 1#6 GND. L I 2"C 4 #310 1 1 EXISTING I ' EXISTING 4 #110 I ' EXISTING 4 #310 & 1 #6 GND. L--------- ��-----------J i &1#6 GND./ I TC,3#2I0 ( &1#6 GND. EXISTING VC, - -I- - J & 1#6 GND.J I EXISTING 1"C, 3#8 I I 4 #6 & 1 D I I J - J - ----- - - - - I & 1#10 GND. I ISOLATED GND. I I IL - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - EXISTING 0 � I I �------r-----------------�------J � --- I---------------- UTILITYXFMR I EXISTING 1-112"C, EXISTING #8 GND. EXISTING #2 GND. I � EXISTING #110 GND. �� EXISTING #110 GND. �- �- L PER N.E.C. l PER N.E.C. 3#1 & 1#6 GND. 1 PER N.E.C. ---L= PER N.E.C. - EXISTING #310 - I - - INSULATED PER N.E.C. I I I I RECEIVED I ELECTRICAL ROOM 109 1 ELECTRICAL ROOM 104 CITY OF TUKWILA SERVICE RISER DIAGRAM PERMIT CENTER NO SCALE 2 4 I I 11 913O 0OTOO E z_N4i5") Q c W", I v �za ill a mN I`n�v z z,-.�, E z= o z Y)w '00 cop J0-Xa(nv 9 �= X > t0� %- C-3 a Oz- C Imo- -I � W V •� CD �'z (L 0- OyW W R W .. V4ZWQ = Ix c %M i$Zia I I-aoiaLL. W 0) C 0 0) C Im C Z N E- C Ici :,. O Co S v v ,r, O�2 N C C� co O U C .4'd' LL (0 3s Cf) LO U _4) U')_ t0 E -U U f4 P m O tI) t) c LO ox 6 O rn C_ t` C U) .0 � F Q Cn .N F0 M s U O N C eEc °- to -o' m JOB #: 416752-040 SQ. FT. CALCS RETAIL: 38,966 S F OFFICES 8. ASSEMBLY: 876 SF .STORAGE/ : 4 890 SF REMAINING f INSTALL: 19153 SF TOTAL: 45,885 SF REMODEL AREA: 6,767 SF CONCEPT: 45K CS1.9 CONCEP��T//D��A/TE��://V��/��// M.M.M G.O.-21��FIXTURE REL. ��//��// . M.//M.M G.O.-13��FINAL R��E//L../ ��//��// M.M.M PROTOTYPE DATEE: ///VVM.M.M STORE NUMBER: 0447 BID & PERMIT SET 12-04-15 PANELBOARD SCHEDULES AND RISERS E3.0 0 ill lk • i •• 14 t,I 111111lob BID & PERMIT SET 12-04-15 PANELBOARD SCHEDULES AND RISERS E3.0 ........... ................ ............. .. .... . .......................... ..... ..................... ................................. ...... . ............. _ ........................... DECK:E TO JUNCTION BOX OR BUS BAR 1-112" MINIMUM DISTANCE FROM BOTTOM OF DECK i MC CABLE ROOF DECK MC CABLE FLUTE TO TOP OF CONDUIT. /. ..... / ...._... ...._........_.... ................... SUPPORT PER THE NEC i _ ...... ...... ......... ........._ __ - _ _ _...... _ _..... _ .._..._... ..._._ _ _ _ ..__. _. _...__.. ..__. _ . _......-- .......... .. - ...._.. ........... .......... __ _ .. _ _ BEAM CLAMP Q _ ............... .. .... ��... / \ - UNISTRUT ' i BAR JOIST :..::...... y VALANCE LIGHT. SEE x I -% E1.0 FOR LOCATIONS. CONDUIT NOTE: ELECTRICAL CONTRACTOR �\ CLAMP PROVIDE 1" SURFACED WALL MOUNTED CONDUIT FROM I TELE MC CABLE. SUPPORT PER / \,\\ / JUNCTION BOX TO JOIST SPACE. ALL CONDUIT, JUNCTION BOXES AND COVERS SHALL BE.. ECURE TO JOIST PER NEC. EXTEND PULL LINE 12 FOR LOW INSTALLED PRIOR TO PAINTING OF WALL, NO EXCEPTIONS. CONDUIT CLAMP TO JUNCTION BOX OR VOLTAGE CABLES. CONDUIT STRAP AS REQUIRED PER NEC (TYPICAL) \ JOIST CHORD OF BAR BUS BAR \ CABLE CLAMP PER SECURE CABLE 12" FROM ll FIXTURE EXTENSION. 4 11116" X 411116" X 2118" SURFACE MOUNTED GROUNDED JUNCTION BOX = - AR JOIST EC. _. NK OVER PLATE AT 8'-4" TO CENTER FOR 8' DISPLAY FIXTURE OR I ItNO _ _..NWITH BLA C FEED FROM CEILING TO DISPLAY LIGHTING TO BE12'-4"TO CENTER FOR 12'-0" DISPLAY FIXTURE. CONTAINED WITHIN FIXTURE DROPS. CONDUIT TO BE ROUTED ON OR BELOW v L BOTTOM CHORD OF BAR JOIST. ....... SECURE GROUND TO 7 MC CABLE SEE SEE POWER PLAN AND LIGHTING PLAN FOR LOCATIONS POWER PLAN FOR FIXTURE EXTENSION. WHITE SUPPORT ANGLE DISPLAY FIXTURE FURNISHED BY DISPLAY CIRCUITING SECURE FIXTURE AT TOP FIXTURE INSTALLER. SECURE SUPPORT ANGLE SEE SHEET POWER PLAN FOR TO BAR JOIST WITH CONTINUATION. APPROVED FASTENER ON BOTH ENDS. TAG AND IDENTIFY PANEL AND CIRCUIT NUMBERS AT CONNECTOR. WALL POWER DROP DETAIL VALANCE LIGHTING DETAIL CONDUIT ROUTING DETAIL 1 2 GALE: N.T.S. FIXTURE EXTENSION FURNISHED BY SCALE: N.T.S. S SCALE: N.T.S. i OTHERS. REMOVABLE FIXTURE PANEL FIXTURE SUPPORT WALL TAG AND IDENTIFY PANEL AND CIRCUIT NUMBERS AT FIXTURE EXTENSION. DISPLAY FIXTURE SUPPORT FRAME FIXTURE EXTENSION FROM DECK. NOTE: ELECTRICAL CONTRACTOR FIXTURE EXTENSION MC CABLE (TYPICAL). ELECTRICAL CONTRACTOR SHALL INSTALL MC CABLE FROM THE SECURED AT DISPLAY BAR JOIST DOWN THE FIXTURE EXTENSION TO THE DISPLAY FIXTURE. SECURE CABLE TO FIXTURE AND FURNISH AND INSTALL ADDITIONAL PULL LINE FOR LOW VOLTAGE CABLES. FIXTURE AS REQUIRED 314" SURFACE MOUNTED CONDUIT FOR BRANCH CIRCUIT WIRING NOTE: ENDCAP DISPLAY RE -USE EXISTING AMP DEVICES FIXTURE SUPPORT WHERE EVER POSSIBLE. FIXTURE EXTENSION LOCATIONS SHOWN ON DRAWINGS ARE APPROXIMATE AND SHALL BE FURNISHED BY OTHERS. IT IS THE FRAME RESPONSIBILITY OF THE ELECTRICAL CONTRACTOR TO EXTEND PULL LINE 12^ COORDINATE THE FIXTURING PHASE OF CONSTRUCTION WITH FOR LOW VOLTAGE MC CABLE. SEE DETAILS ON RELOC WIRING THE DISPLAY FIXTURE INSTALLER AND ENSURE THAT SUFFICIENT CABLES. SHEET E4.0 SHEET FOR MANPOWER, LIFTS, MATERIALS, ETC. TO BE USED, SHALL BE RELOC PLUGSTRIP ON-SITE DURING FIXTURING. CONTINUATION 0' - T (TYPICAL). SECURE CABLE TO FIXTURE AS REQUIRED SURFACE MOUNTED GROUNDED JUNCTION MC CABLE RUN ONL SURFACE MOUNTED GROUNDED JUNCTION OVERALL DIMENSION FROM WALL BOX WITH QUAD RECEPTACLE MOUNTED UNDERSIDE OF FIXTURE BOX WITH QUAD RECEPTACLE MOUNTED SURFACE TO FRONT DISPLAY (TYPICAL). TO GONDOLA (TYPICAL). TO GONDOLA (TYPICAL). L FIXTURE EXTENSION DETAIL DEVICE MOUNTING IN LOW BAY GONDOLAS SONY RELOC WIRING DETAIL 4 6 SCALE: N.T.S. SCALE: N.T.S. 5 SCALE: N.T.S. SEE E2.0 PLAN FOR CONTINUATION REMOVABLE FUTURE PANEL FIXTURE SUPPORT 2" FIXTURE EXTENSION TO BE PLACED ON OUTSIDE OF PAD. fI X01 OO 106^� 00 00 00 WALL 106" 00 00 00 00 00 00 F r 2 X 4 X 2-112"D WALL CASE BOX WITH SINGLE OPENING AND 314" KNOCK OUT ON BACK OF BOX. 4 0" (TYPICAL). O O O 67" O O O O O 67" O O O O 00 Do O O O O MC CABLE. EMT AS REQUIRED. (TYPICAL) 314" SURFACE MOUNTED CONDUIT FOR BRANCH CIRCUIT WIRING GRAY DUPLEX RECEPTACLE COVER PLATE 314" CONDUIT EXTENSION FROM 29" O O O O JUNCTION BOX COVER TO WALL CASE. PROVIDE QUADRAPLEX RECEPTACLES MOUNTED PROVIDE GROUND WIRE WITH AS FAR TOWARD BACK OF TOTEM AND AS CLOSE CONDUIT CONDUCTORS FOR BRANCH TO CENTER SUPPORT AS POSSIBLE. '0-7" (TYPICAL). CIRCUITWIRING. i OVERALL DIMENSION FROM WALL PLASMA /LCD DISPLAY WALL ELEVATION SURFACE TO FRONT OF MUD RING SONY VENDOR PAD DETAIL WALL CASE Q 6 SCALE: N.T.S. V SCALE: N.T.S. REVIEWED.FOR COMPLIANCE WITH NFPA 70 - NEC JAN 13 2016 City of Tukwila BUILDING DIVISION RECEIVED CITY OF TUKWI A JAN 0 6 23 PERMIT CEN` ; NOT USEDNOT USED NOT USED NOT USEDAS 0 SCALE: N.T.S. SCALE: N.T.S. SCALE: N.T.S. SCALE: N.T.S. t— z Wv1 0 oo ` p -- STORAGE/ 4,890 REMAINING: ZN�MrM O I— La OW1� 1 U -ct �L0 L_ a SF ?Q zZr.N E Z Z �gz U) U YQ n- 0 �v0 m (n.. �- CL -Q �oJ C.�ck:U 3 0 �I2_ 0 F J " Li v Ld ~< w U Q3ZpX2 C= m a C) �00 W a- U_ G h Lo O co V V O Ln O N O O X Lo � O Q E No L w0 L o U) c a ui L E E s E a CD z p mw C Z R JOB #: 416752-040 SQ. FT. CALCS RETAIL: 38,966 SF OFFICES & ASSEMBLY: 876 SF STORAGE/ 4,890 REMAINING: SF INSTALL: 15153 SF TOTAL: 455885 SIF REMODEL AREA: 65767 SF CONCEPT: 45K CS1.9 CONCEPT DATE: XX"XX"XX G.O. -21 FIXTURE REL. XX.XX.XX G.O. -13 FINAL REL. XX.XX.XX PROTOTYPE DATE: XX.XX.XX STORE NUMBER: 0447 BID & PERMIT SET 12-04-15 ELECTRICAL DETAILS E4.0 f • BID & PERMIT SET 12-04-15 ELECTRICAL DETAILS E4.0