Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Permit EL16-0165 - EURO PRODUCTS - TENANT IMPROVEMENT BUILD OUT
14570 INTERURBAN AVE S EL16-0165 City of Tukwila • Department of Community Development • 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Inspection Request Line: 206-438-9350 Web site: http://www.TukwilaWA.gov ELECTRICAL PERMIT Parcel No: 3365901630 Permit Number: EL16-0165 Address: 14570 INTERURBAN AVE S Issue Date: International Residential Code Edition: Permit Expires On: 8/22/2016 Project Name: EURO PRODUCTS 2014 Owner: 2012 Name: SANFT LOUIE 2014 Address: 6120 52ND AVE S, SEATTLE, WA, 2012 98118 2012 Contact Person: 2012 Name: SCOTT HUEBNER Phone: (206) 832-8074 Address: 5005 THIRD AVE S, SEATTLE, WA, 98134 Contractor: Name: MCKINSTRY CO LLC Phone: (206) 762-3311 Address: PO BOX 24567, SEATTLE, WA, 98124 License No: MCKINCL942DN Expiration Date: 3/15/2016 Lender: Name: Address: DESCRIPTION OF WORK: TENANT IMPROVEMENT BUILDI-OUT, GENERAL PURPOSE POWER, FA ROUGH -IN, TELE/DATA ROUGH -IN MCKINSTRY JOB #105823-001 Valuation of single family: $0.00 Fees Collected: $698.50 Valuation of mf/comm: $25,000.00 Type of Work: TENANT IMP Electrical Service Provided by: PUGET SOUND ENERGY Water District: TUKWILA Sewer District: TUKWILA SEWER SERVICE Current Codes adopted by the City of Tukwila: International Building Code Edition: 2012 National Electrical Code: 2014 International Residential Code Edition: 2012 WA Cities Electrical Code: 2014 International Mechanical Code Edition: 2012 WAC 296-46B: 2014 Uniform Plumbing Code Edition: 2012 WA State Energy Code: 2012 International Fuel Gas Code: 2012 Permit Center Authorized Signature: [/I Date: I hearby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this developmentp a d e t conditions attached to this permit. i Signature: c' Date: �( Print Name: d C © I( AJ�r_" This permit shall become null and void if the work is not commenced within 180 days for the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. PERMIT CONDITIONS: 1: 'ELECTRICAL PERMIT CONDITIONS' 2: A copy of the electrical work permit shall be posted or otherwise made readily accessible to the Electrical Inspector at each work site. 3: Approved plans shall be maintained at the construction site and shall be readily available to the Electrical Inspector. 4: All electrical work shall be in accordance with NFPA 70 - NEC, and requirements for electrical installations, Chapter 296-46B WAC. 5: When any portion of the electrical installation is to be hidden from view by permanent placement of parts of the building, such equipment shall not be concealed until it has been inspected and approved by the Electrical Inspector. 6: The issuance of an electrical work permit shall not be construed to be a permit for, or an approval of, any violation of the provisions of the electrical code or other ordinances of the jurisdiction. Permits or related documentation that presumes to grant this authority are therefore not valid. 7: Any change in the scope of work described by the electrical work permit shall require additional work permits. Where approved plans have been issued, revisions to the plans and additional review may be required. PERMIT INSPECTIONS REQUIRED Permit Inspection Line: (206) 438-9350 2100 ELECTRICAL FINAL 7003 ROUGH -IN ELECTRICAL 7002 SERVICE 7001 UNDERGROUND/SLAB CITY OF TUKWi—. i Community Development Department Permit Center • 6300 Soutlicenter Blvd., Suite 100 Tukwila, WA 98188 http://www.TukwilaWA.gov Electrical Permit No. Project No. Date Application Accepted: Date Application Expires:( (n (For office use only) ELECTRICAL PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. "Please Print" SITE LOCATION King Co Assessor's Tax No.: Site Address: 14570 Interurban Ave South Suite Number: C-100 Floor: Tenant Name: Euro Products New Tenant: .....Yes ❑ ..No PROPERTY OWNER Name: Sanft, Louie Address: 6120 52nd Ave South City: Seattle State: WA Zip: 98118 CONTACT PERSON — person receiving all project communication Name: Scott Huebner / McKinstry Address: 5005 3rd Ave South City: Seattle State: WA Zip: 98134 Phone: (206) 920-6051 Fax: Email: scotthu@mckinstry.com ELECTRICAL CONTRACTOR INFORMATION Company Name: McKinstry Co LLC Address: 5005 3rd Ave S City: Seattle State: WA Zip: 98134 Phone: (206) 762-3311 Fax: Contr Reg No.: CCMCKINCL94 Exp Date: 03/16/2016 Tukwila Business License No.: BUS -0994320 Valuation of Project (contractor's bid price): $ 25,000 Scope of Work (please provide detailed information): TI Build out, General Purpose Power, FA Roughin, Tele/Data, AN rough in McKinstry Job#105823-001 Job Site Contact: Jason Bogart 206-786-9339 or Brandon Kees 206-255-6104 Will service be altered? ❑ Yes ❑✓ No Type of Use: Warehouse / Office Type of work: ❑ New ❑ Addition ❑ Service Change 0 Low Voltage ❑ Generator Fire Alarm Property Served by: 0 Puget Sound Energy ❑ Seattle City Light HP,Applications`Forms-Applications On Line.2011 Applications Electrical Permit Application Revised 8-9-1 I.docx Revised: August 2011 bh Adding more than 50 amps? ❑✓ Yes ❑ No ❑ Remodel 0 Tenant Improvement ❑ Telecommunication ❑ Temporary Service Page 1 of 2 RESIDENTIAL NEW RESIDENTIAL SERVICE ❑ New single family dwellings ................................... $152.85 (including an attached garage) ❑ Garages, pools, spas and outbuildings ........................ $81.90 ea ❑ Low voltage systems (alarm, furnace thermostat) ................................ $59.85 ea RESIDENTIAL REMODEL AND SERVICE CHANGES ❑ Service change or alteration ...................................... $81.90 (no added/altered circuits) Temporary service (residential) ................................. ❑ Service change with added/altered circuits ................. $81.90 $78.75 number of added circuits ....................... $11.55 ea ❑ Circuits added/altered without service change ........... $54.60 (up to 5 circuits) Carnivals.................................................................... ❑ Circuits added/altered without service change ........... $54.60 $10.50 ea (6 or more circuits) ............................................... $7.65 ea ❑ Meter/mast repair ....................................................... $68.25 ❑ Low voltage systems ................................................. $59.85 (alarm, furnace thermostat) PERMIT APPLICATION NOTES - MULTI -FAMILY AND COMMERCIAL Fees are based on the valuation of the electrical contract. Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation The Building Official may grant one extension of time for an additional period not to exceed 90 days. The extension shall be requested in writing and justifiable cause demonstrated. I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. i narP. 02/15/2016 Print Name: Scott Huebner Day Telephone: (206) 920-6051 Mailing Address: 5005 3rd Ave S Seattle WA 98134 City State Zip H:.Applications'Forms-Applications On Line,2011 Application§tElectrical Permit Application Revised 3-9-1 I.docx Revised: August 2011 bh Page 2 of 2 MISCELLANEOUS FEES ❑ Temporary service (residential) ................................. $63.00 ❑ Temporary service (generator) ................................... $78.75 ❑ Manufactured/mobile home service ........................... $84.00 (excluding garage or outbuilding) ❑ Carnivals.................................................................... $78.75 Number of concessions ......................... $10.50 ea Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation The Building Official may grant one extension of time for an additional period not to exceed 90 days. The extension shall be requested in writing and justifiable cause demonstrated. I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. i narP. 02/15/2016 Print Name: Scott Huebner Day Telephone: (206) 920-6051 Mailing Address: 5005 3rd Ave S Seattle WA 98134 City State Zip H:.Applications'Forms-Applications On Line,2011 Application§tElectrical Permit Application Revised 3-9-1 I.docx Revised: August 2011 bh Page 2 of 2 DESCRIPTIONS PermitTRAK • QUANTITY PAID $766.75 EL16-0165 Address: 14570 INTERURBAN AVE S Apn: 3365901630 $698.50 ELECTRICAL $671.63 PLAN CHECK FEE R000.345.832.00.00 0.00 $134.33 PERMIT FEE MULTI-FAM/COMM R000.322.101.00.00 0.00 $537.30 TECHNOLOGY FEE $26.87 TECHNOLOGY FEE 11000.322.900.04.00 0.00 $26.87 EL16-0166 Address: 14570 INTERURBAN AVE S Apn: 3365901630 $68.25 ELECTRICAL $65.00 PERMIT FEE MULTI-FAM/COMM R000.322.101.00.00 0.00 $65.00 TECHNOLOGY FEE $3.25 TECHNOLOGY FEE TOTAL FEES PAID ' R000.322.900.04.00 0.00 $3.25 .. .75 Date Paid: Monday, February 22, 2016 Paid By: JIM THOMAS Pay Method: CREDIT CARD 077572 Printed: Monday, February 22, 2016 9:04 AM 1 of 1W SYSTEMS INSPECTION RECORD 21 Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 F. Project: � n ^ � l�Sr✓ Type of inspection: Address: /A17VP6 pate Called: Special Instructions: pate Wanted: p.m. Requester: Phone No: u paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. INSPECTION RECORD (146 -Retain a copy with permit INSPECTION N0, P RMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Project: LO Type of Inspection: Address: /41 Date Called: Special Instructions: Date Wanted: a.m. Requester: Phone No: 0 Approved per applicable codes. E Corrections required prior to approval. COMMENTS: Inspector:. JDate: G /f1 i� _ _ 0 REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. INSPECTION RECORD Retain Retain a copy with permit INSPEC ION N0. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Project: Type of Inspection Address: a2 Date Called: Special Instructio s: Date Wanted: .ril. p.m Requester: Phone No: U REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. PERMIT COORD COPY PLAN REVIEW/ROUTING SLIP PERMIT NUMBER: EL16-0165 PROJECT NAME: EURO PRODUCTS DATE: 02/22/16 SITE ADDRESS: 14570 INTERURBAN AVE S - SUITE 100 X Original Plan Submittal Revision # before Permit Issued Response to Correction Letter # Revision # after Permit Issued DEPARTMENTS: Building Division Fire Prevention ❑ Planning Division ❑ Public Works ❑ Structural ❑ Permit Coordinator In PRELIMINARY REVIEW: DATE: 02/23/16 Not Applicable ❑ Structural Review Required ❑ (no approvallreview required) REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: DUE DATE: 03/22/16 Approved ❑ Approved with Conditions XI Corrections Required ❑ Denied ❑ (corrections entered in Reviews) (ie: Zoning Issues) Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: 17/18/2013 MCKINSTRY CO LLC Page 1 of 3 Home Espanol Contact. Search L&I fat A-7.. Index Help My I'm Safety & Health Claims & Insurance Workplace Rights Trades & Licensing Washington State Department of Labor & Industries MCKINSTRY CO LLC Owner or tradesperson PO BOX 24567 KELLY, PETER SEATTLE, WA 98124 Principals 206-762-3311 ALLEN, DEAN KING County CHARLES,PARTNER/MEMBER MOORE, DOUGLAS J, PARTNER/MEMBER $4,000.00 ALLEN, DAVID, PARTNER/MEMBER TEPLICKY, JOSEPH W (BILL), PARTNER/MEMBER Effective date BLACK, STEPHEN, AGENT 03/06/2011 Doing business as MCKINSTRY CO LLC WA UBI No. Business type 602 569 922 Limited Liability Company License Verify the contractor's active registration / license / certification (depending on trade) and any past violations. Electrical Contractor Active. ............................................................... Meets current requirements. License specialties GENERAL License no. MCKINCL942DN Effective — expiration 03/15/2006— 03/15/2018 Designated administrator _....................._....... Active. KELLY, PETER Meets current requirements. License type License no. Master Electrician KELLYP'962NQ Bond ................ Western Surety Co $4,000.00 Bond account no. 929523050 Received by L&I Effective date 02/25/2011 03/06/2011 Expiration date Until Canceled Bond history Savings No savings accounts during the previous 6 year period. License Violations Infraction no. Satisfied https:Hsecure.Ini.wa.gov/verify/detail.aspx 03/02/2016 ELECTRICAL ABBREVIATIONS ABBREVIATION DESCRIPTION ABBREVIATION DESCRIPTION ABBREVIATION DESCRIPTION ABBREVIATION DESCRIPTION ABBREVIATION DESCRIPTION ABBREVIATION DESCRIPTION A AMP, AMPERES EPR ETHYLENE PROPYLENE RUBBER K THOUSAND NO. NUMBER SPEC SPECIFICATIONS UTP UNSHIELDED TWISTED PAIR AC 6" ABOVE COUNTER OR 3" ABOVE BACKSPLASH EQUIP EQUIPMENT KCMIL THOUSAND CIRCULAR MILS NO NORMALLY OPEN SQ SQUARE V VOLTS AF AMP FRAME EWC ELECTRIC WATER COOLER KV KILOVOLT NTS NOT TO SCALE SS STAINLESS STEEL VM VOLTMETER AFF ABOVE FINISHED FLOOR EWH ELECTRIC WATER HEATER KVA KILOVOLT -AMPERES OC ON -CENTER ST SHUNT TRIP or STREET W WATTS or WIRE AFG ABOVE FINISHED GRADE EXIST OR (E) EXISTING KVAR KILOVOLT -AMPERES REACTIVE OCPD OVERCURRENT PROTECTIVE DEVICE STD STANDARD W/ WITH AHU AIR HANDLING UNIT F FUSE OR FAHRENHEIT KW KILOWATTS OD OUTSIDE DIAMETER STL STEEL WH WATT-HOUR AIC AMPS INTERRUPTING CURRENT FA FIRE ALARM KWH KILOWATT-HOURS OFCI OWNER FURNISHED CONTRACTOR INSTALLED STRUCT STRUCTURAL WHSE WAREHOUSE AL ALUMINUM FACP FIRE ALARM CONTROL PANEL KWHD KILOWATT-HOUR DEMAND OL OVERLOADS SUB SUBSTITUTE WM WIREMOLD AT AMP TRIP FBO FURNISHED BY OTHERS LED LIGHT EMITTING DIODE OS OCCUPANCY SENSOR - ADJUSTABLE SV SOLENOID VALVE W/O WITHOUT ATS AUTOMATIC TRANSFER SWITCH FC FOOTCANDLE LS LIMIT SWITCH PA PUBLIC ADDRESS SVC SERVICE WP WEATHERPROOF/NEMA 3R MINIMUM AUTO AUTOMATIC FLA FULL LOAD AMPERES LTG LIGHTING PB PULLBOX SW SWITCH X REACTANCE AUX AUXILIARY FLEX FLEXIBLE CONDUIT LV LOW VOLTAGE PC PHOTOCELL- MOUNT FACING NORTH SWBD SWITCHBOARD XFMR TRANSFORMER AWG AMERICAN WIRE GAGE FS FLOW SWITCH M or MTR MOTOR PF POWER FACTOR SYM SYMMETRICAL XHHW MOISTURE AND HEAT RESISTANT BATT BATTERY FT FOOT or FEET MAX MAXIMUM PH OR 0 PHASE SYNC SYNCHRONOUS X CROSS-LINKED SYNTHETIC POLYMER BFC BELOW FINISHED CEILING FV FULLVOLTAGE MCA MINIMUM CIRCUIT AMPACITY PNL PANEL SYS SYSTEM XLP CROSS-LINKED POLYETHYLENE C CONDUIT or CENTIGRADE FVNR FULL VOLTAGE NON -REVERSING MC METAL CLAD CABLE PRI PRIMARY TB TERMINAL BLOCK XP EXPLOSION -PROOF CAT CATALOG FVR FULL VOLTAGE REVERSING MCB MAIN CIRCUIT BREAKER PSE PUGET SOUND ENERGY TD TIME DELAY Z IMPEDANCE CB CIRCUIT BREAKER G or GND GROUND MCC MOTOR CONTROL CENTER PT POTENTIAL TRANSFORMER TC TELECOMMUNICATIONS OUTLET (PHONE/DATA) CKT CIRCUIT GA GAGE MECH MECHANICAL PVC POLYVINYL CHLORIDE TEMP TEMPERATURE or TEMPORARY AL1 CLG CEILING GEN GENERATOR MFR MANUFACTURER PWR POWER TERM TERMINAL CO CONDUIT ONLY - PROVIDE PULL STRING GFCI GROUND FAULT CIRCUIT INTERUPTER MH MANHOLE QTY QUANTITY THHN HEAT -RESISTANT THERMOPLASTIC NUMBER OF HEADS AS SHOWN OR SPECIFIED CPT CONTROL POWER TRANSFORMER GRS GALVANIZED RIGID STEEL MIN MINIMUM R RESISTANCE or RADIUS THWN MOISTURE AND HEAT RESISTANT THERMOPLASTIC CT CURRENT TRANSFORMER HH HANDHOLE MISC MISCELLANEOUS REC CONVENIENCE RECEPTACLE TOS TOP OF SUPPORT or STEEL or SLAB �s CU COPPER HID HIGH INTENSITY DISCHARGE MLO MAIN LUGS ONLY REQD REQUIRED TS TAMPER SWITCHI..1 ri -�_ 9 DC DIRECT CURRENT HOA HAND -OFF -AUTO SELECTOR SWITCH MOCP MAXIMUM OVERCURRENT PROTECTION REV REVISION TSP TWISTED SHIELDED PAIR OC i- EQUI FOFt DIA DIAMETER HP HORSEPOWER MSB MAIN SWITCHBOARD- SERVICE ENTRANCE RATED RPM REVOLUTIONS PER MINUTE TTB TELEPHONE TERMINAL BOARD FLC—Pl LIGHTING CONTROL PANEL DISC DISCONNECT HPS HIGH PRESSURE SODIUM MTD MOUNTED RS RAPID START TTC TELEPHONE TERMINAL CABINET f�+f ON DOWN HTR HEATER MTG MOUNTING RVAT REDUCED VOLTAGE AUTOTRANSFORMER TYP TYPICAL q,�Q 0 ESCLICd DSB DISTRIBUTION SWITCHBOARD IBE INSTALLED/CONNECTED BY ELECTRICAL MVA MILLION VOLTAMPERES SCL SEATTLE CITY LIGHT UC UNDER -COUNTER erPlumbing DWG DRAWING IBO INSTALLED BY OTHERS N NEUTRAL SEC SECONDARY OF UNDER -FLOOR 20/6 ELECTRICALLY HELD, NO/NC AUXILIARY CONTACTS E EMERGENCY DESIGNATION IC INTERRUPTING CURRENT NC NORMALLY CLOSED SECT SECTION UG UNDERGROUND 1 bas Piping EF EXHAUST FAN ID INSIDE DIAMETER NEC NATIONAL ELECTRICAL CODE -JURISDICTION CURRENT SF SUPPLY FAN or SQUARE FEET UH UNIT HEATER S SWITCH, TYPE AS INDICATED, MOUNT+46" AFF LION VFD MANUFACTURER. 2 2 -POLE D DIMMER CI Of Tukwii� `�' EL ELEVATION (HEIGHT) IN INCH or INCHES NEMA NATIONAL ELECTRICAL MANUFACTURERS ASSOCIATION SHLD SHIELD or SHIELDED UL UNDERWRITER LABORATORIES K KEY SWITCH OC OCCUPANCY SENSOR M MOTOR RATED,SIZE OL PER MOTOR SIZE EMT ELECTRICAL METALLIC TUBING INST INSTANTANEOUS NIC NOT IN CONTRACT SHT SHEET LION UNLESS OTHERWISE NOTED BUIL*MING DIVISION EOL END -OF -LINE DEVICE JB orJ-BOX JUNCTION BOX NL NIGHT LIGHT SK SKETCH UPS UNINTERRUPTABLE POWER SUPPLY SYMBOLS (NOTE 1,2) SYMBOLS (NOTE 3) SYMBOLS (NOTE 3) SYMBOL DESCRIPTION SYMBOL DESCRIPTION SYMBOL DESCRIPTION REFERENCE LUMINAIRE SCHEDULE FOR DETAILS ON LUMINAIRES ALL RECEPTACLES TO BE GROUNDING TYPE LION MOUNTED AT +18" (NOTE 1) INCLUDING MOUNTING TYPE, HEIGHT, LAMPING, VOLTAGE, (NOTE 3) AFF LION. TYPE AS INDICATED MANUFACTURER, ETC. WP WEATHERPROOF GFCI GROUND FAULT CIRCUIT INTERRUPTER VARIOUS LIGHTING SYMBOLS ARE USED TO GENERALIZE XP EXPLOSION PROOF (NOTE 2) SHAPE/STYLE OF LUMINAIRE. REFERENCE LUMINAIRE SCHEDULE FOR DETAILS. SIMPLEX RECEPTACLE DUPLEX RECEPTACLE DELTA -WYE, DRY TYPE TRANSFORMER. VOLTAGE, KVA RATING AS GF1—LUMINAIRE DESIGNATION DOUBLE DUPLEX RECEPTACLE lio INDICATED ON PLANS, 150°C RISE, 220°C INSULATION CLASS STANDARD SPLIT WIRED DUPLEX RECEPTACLE 2a,b —CIRCUIT & SWITCHING SIMPLEX RECEPTACLE IN FLOOR BOX -FLUSH MOUNTED ® DUPLEX RECEPTACLE IN FLOOR BOX - FLUSH MOUNTED PANEL SF® BF1 LXP2N 208Y/120 BRANCH CIRCUIT PANELBOARD. VOLTAGE, AMPACITYAS INDICATED. ® DOUBLE DUPLEX RECEPTACLE IN FLOOR BOX- FLUSH MOUNTED SF2 O SOLID LINETYPE INDICATES SURFACE, CEILING OR WALL MOUNTING ®100A SPLIT WIRED DUPLEX RECEPTACLE IN FLOOR BOX -FLUSH MOUNTED MCB WF� SF3 ® ELECTRICAL CONNECTION TO EQUIPMENT SPECIFIED, FURNISHED XX,XXX AVAILABLE FAULT CURRENT AT NODE INDICATED FOWf2 AND INSTALLED BY OTHER TRADES X SPECIAL PURPOSE RECEPTACLE -TYPE AS NOTED XXKAIC AIC RATING OF EQUIPMENT GF1 R_R1 J C� 61 POWER POLE WITH DIVIDER FOR TELECOMM WIRING 100/4 FEEDER DESIGNATION, REFER TO FEEDER SCHEDULE DASHED LINETYPE INDICATES RECESSED OR PARTIALLY RECESSED GF2 MOUNTING r>I DEVICE OPERATOR PROVIDED BY OTHERS,INSTALLED BY ELECTRICAL '1 R TRANSFER SWITCH, SIZE, TYPE, POLES AS INDICATED ® MOTOR STARTER IN NEMA 1 ENCLOSURE, SIZE AS INDICATED, a SF1 GF1 X 3 -POLE LION Ea— Ea MOTOR STARTER AND DISCONNECT TYPE AS LUMINAIRE ON EMERGENCY SOURCE (TYPICAL)COMBINATION LUMINAIRE ON EMERGENCY SOURCE (TYPICAL) C SF2 RR1 � Y/ZW INDICATED, 3 -POLE LION C� GROUND FAULT SENSOR AND INDICATING LIGHT ® a STARTER SIZE X DISCONNECT RATING Y NEMA TING M POTENTIAL TRANSFORMER EX1 EX2 EXIT SIGN ON EMERGENCY SOURCE ARROW INDICATES DIRECTION OF EGRESS Z FUSE SIZE SHADING INDICATES FACE (SINGLE OR DOUBLE) EP -o'-O-=I FUSED DISCONNECT, TYPE AS INDICATED, 3 -POLE LION CURRENT TRANSFORMER X/Y/Z X DISCONNECT RATING o SUSPENDED LUMINAIRE Y NEMA RATING Z FUSE SIZE CUSTOMER METERING. PROVIDE METERING TO INDICATE VOLTAGE, AL1 CM AMPS, POWER FACTOR, KW, KVA. PROVIDE NECESSARY CT'S, PT'S AND RELATED EQUIPMENT. POLE MOUNTED AREA LUMINAIRE � —o -o— NON-FUSED DISCONNECT, TYPE AS INDICATED, 3 -POLE LION X/Y X DISCONNECT RATING Y NEMA RATING ®M UTILITY METERING. REFERENCE SERVING UTILITY STANDARDS FOR TRACK LIGHTING REQUIREMENTS. NUMBER OF HEADS AS SHOWN OR SPECIFIED INCLUDES ALL TRACK AND COMPONENTSr,1, /v MOTOR CONNECTION. MOTOR BY OTHERS. SIZE AS INDICATED BY LIGHTING CONTROL PANEL. PANELTO MEET REQUIREMENTS OF MECHANICAL CALLOUT SYMBOL LCP ADOPTED ENERGY CODE. REFERENCE LIGHTING CONTROL TC TIME CLOCK XX S MECHANICALCALLOUTSYMBOL. SCHEDULES V/P XX EQUIPMENTTYPE FACP FIR, ALARM CONTROL PANEL. PC PHOTOCELL CONTROL YY EQUIPMENT DESIGNATION S SIZE(HP,MCA,FLA,KW) V/P VOLTAGE/PHASE OF LINE VOLTAGE (120V) SMOKE DETECTOR OC OCCUPANCY SENSOR LV MOTOR THERMAL OVERLOADS, SIZE PER MOTOR, (3) LION FLC—Pl LIGHTING CONTROL PANEL CL CIRCUIT BREAKER, NUMBER INDICATES SIZE(A) AND POLES FIRE/SMOKE DAMPER. DAMPER BY OTHERS. b C8 ) LSIG ST SHUNTTRIP BATTERY POWERED EMERGENCY LIGHT CL CURRENT LIMITING RESIDENTIAL MEDIA DISTRIBUTION UNIT WITH INTEGRAL 130/3 L LONG TIME ADIUSTABILITY CONVENIENCE OUTLET. q,�Q S EOUS LJ COMBINATION BATTERY POWERED EGRESS LIGHT AND EXIT INSTASHORNTANEOUS ADJUSTAY I INSTANTANEOUS ADJUSTABILITY G GROUND FAULT ADJUSTABILITY LC ® LIGHTING CONTACTOR IN NEMA 1 ENCLOSURE, 120V COIL, FK] KIRK-KEYINTERLOCK 20/6 ELECTRICALLY HELD, NO/NC AUXILIARY CONTACTS 30 A/P A INDICATES CONTACT AMP RATING --am— FUSE, SIZE(A) AS INDICATEDVARIABLE FREQUENCY DRIVE. SUPPLIED BY MECHANICAL. P INDICATES NUMBER OF POLES (NO) VFD COORDINATE INSTALLATION LOCATION. COORDINATE DISCONNECT T THERMOSTAT, +60" AFF LION. UNIT CONTROLLED INDICATED. REQUIREMENT EITHER AT LINE SIDE OR LOAD SIDE DEPENDING ON S SWITCH, TYPE AS INDICATED, MOUNT+46" AFF LION VFD MANUFACTURER. 2 2 -POLE D DIMMER 3 3 -WAY LV LOW VOLTAGE 4 PB PULLBOX 4 -WAY P PILOT LIGHT 225A/3P K KEY SWITCH OC OCCUPANCY SENSOR M MOTOR RATED,SIZE OL PER MOTOR SIZE HH HANDHOLE,12"x18"x18" DEEP, FIBERGLASS WITH LID LABELLED 'ELECTRICAL' LION. /-1 G E GENERATOR SET. SIZE AS INDICATED, MAIN BREAKER SIZE AS INDICATED. DUAL LEVEL SWITCHING, INSIDE AND OUTSIDE LAMPS OF LUMINAIRE ® GROUND ROD. 3/4"X10' COPPER CLAD STEEL LION. TO BE SWITCHED SEPARATELY CIRCUITING SYMBOLS UNMARKED CIRCUIT IS CONCEALED IN CEILING OR WALL 1/2"-2#12,1#12G (LION) BEGINNING OF INDIVIDUAL CIRCUIT CONDUIT, STUBBED, CAPPED AND MARKED, WITH PULL STRING CONDUIT DOWN I CONDUIT UP CURRENT CARRYING CONDUCTORS NEUTRAL GROUNDING CONDUCTOR ISOLATED GROUND No LN1A-2,4,6 PANEL HOMERUN (3/4" MIN.) CIRCUIT 3/4"-3#12,1#12G EXISTING RACEWAY QUANTITY SIZE GF1 CONCEALEDIN FLOOR r OR UNDER GROUND + CONDUCTORS -CONNECTED 4a,b CTION BOX SIZED PERCODE + + CONDUCTORS -NOT CONNECTED PER PROJECT SCOPE 1. TENANT IMPROVEMENT IN'C100' SUITE OF EXISITNG BUILDING. INCLUDES ALL NEW LIGHTING AND RECEPTACLES. I 2. ELECTRICAL SERVICE IS EXISTING AS WELL AS ALL PANELS/ TRANSFORMERS. INSTALLED UNDER PREVIOUS SCOPE OF WORK. PROJECT: r astry Of Your Building SEATTLE: 5005 3RD AVENUE S PO BOX 24567 SEATTLE, WA 98124 1-800-669-6223 PORTLAND: 16790 NE MASON ST PORTLAND, OR 97230 503-331-0234 www.mckinstry.com EURO PRODUCTS 14570 INTERURBAN AVE S BUILDING C, SUITE #1 TUKWILA, WA 98168 CONSULTANTS: FILE COPY Permit it wx/ 1 Plan review approval is subject to errors and omissions. Approval of I^cnsiructiun documents does not authoriza the violation of any adopted code & ordinance. Recoipt c itions is acknowledged:Of approved Field 5M an� By: '_ `3 Date: __ No changes shah be made to the swp of work witho at prior approval of Til%r-r a BIS Ming Division. VOTE: Rsxs rAl require a new plan submittal and may include addiiiionai plan review foes. 1 � R g ��• i wr b FEB 2 4 2016 3b NG DIV SHEET INDEX EO.00 SYMBOLS AND ABBREVIATIONS EO.01 ELECTRICAL SCHEDULES E1.00 ONE LINE DIAGRAM / SITE PLAN/ ELECTRICAL PANEL SCHEDULES E4.00 ELECTRICAL PLAN RECEIVED CITY OF TUKWILA FEB 22 2016 Cray of Tukwila BUILDING DIVISION REGISTRATION: EXPIRES: 04/14/2016 ISSUES: 02/19/2016 ELEC. PERMIT SET NO. DATE DESCRIPTION McKINSTRY DIVISION: ELECTRIC DESIGNED BY: DRAWN BY - CHECKED BY. JOB NUMBER: DATE: SHEET TITLE: PAUL HIGHLEY LPH PAUL HIGHLEY 105823-001 02/19/2016 SYMBOLS AND ABBREVIATIONS SHEET NUMBER: PERMIT CENTER EO.00 2012 Washington State Energy Code Compliance Forms for Commercial Buildings including R2 & R3 over 3 stories and all R1 Revised Jan 2014 2012 Washington State Energy Code Compliance Forms for Commercial Buildings including R2 & R3 over stories and all R1 Project Info Project Address EURO PRODUCTS Date 2/19/2016 Compliance fortes 14570 INTERURBAN AVE S For Building Department Use do not require a password to use. 1680 BUILDING C, SURE 100, TUKWILA WA 98168 Applicant Name: MCKINSTRY COMPANY Instructlonaland 37 calculating cells are 4 Applicant Address: 5005 3RD AVE S, SEATTLE, WA writa-protacted. eristing builidng, include all applicable existing Space Types and gross interior areas. 14 c. Dxument new fixtures and all existing to remain fixtures In the Proposed Lighting table. Applicant Phone: 206.832.8252 Project Description New Building Addition Alteration Lighting Compliance Path Lighting Power Density Calculations Total Building Performance Clear Maximum Allowed Lighting Wattage (If Total Building Performance then only LGT-CHK is required.) Lighting Power Allowance room #) Space Type' Wads per fV Method Building Area Method Space -By -Space Method Clear Selection required to E4.00 Office -Open plan 0.98 enable LPA fors DIMMING WTfH INGEGRAL OCCUPANCY CONTROL Interior Lighting System NEW LIGHTING FOR TENANT IMPROVEMENT IN C10O SPACE. REMAINDER OF BUIDING IS UNOCCUPITED. Description P LIGHTING SYSTEM CONSISTS OF NEW LED LIGHTING FOR ALL INTERIOR SPACES WITH LOCAL / NETWORK 3 CONTROLS AS PRESCRIBED BY CODE. E4.0 FINAL LIGHTING CONTROL DRAWINGS TO BE PROVIDED BY LIGHTING CONTROL VENDOR. Briefly describe lighting system type and features. areas served on plans; Additions and Change of Space Use (C101.4.3 & C101.4.4) Addition area or Change of Space Use area complies with all applicable provisions as stand alone project Addition area is combined with existing building lighting systems to demonstrate compliance Wth all applicable provisions per C101.4.3 Provide Building Area Method (LTG -INT -BLD) or Space -By -Space Method (LTG -INT -SPACE) Compliance For. Document maximum allowed and proposed (including existing d applicable) lighting wattage ofAddrtfon or Change of Use space. Provide applicable lighting controls per C405.2 and commissioning of lighting controls per C405.13. Alterations, Renovations and Repairs (0101.4,3.1) 60% or more of luminaires in space replaced Provide Building Area Method (LTG -INT -BLD) or Space -By -Space Method (LTG -INT -SPACE) Compliance For. Document maximum allowed wattage within the lighting retrofd space in Maximum Allowed Wattage table and proposed (including existing) lighting wattage in Proposed Wattage table. Relrofd and non -retrofit spaces shall be documented separately using multiple fors. Less than 60% of luminaires in space replaced Provide a separate Space -By -Space Method (LTG -INT -SPACE) Compliance For for this retrofit area. Document existing total wattage within the lighting retrofit space in cell provided in the Maximum Allowed Wattage table. Document proposed (including existing) lighting wattage In the Proposed Wattage fable. Lamp and/or ballast replacement within existing luminaires only- existing total interior building wattage not increased New wiring installed to serve added fixtures and/or fixtures relocated to new circuit Provide applicable manual lighting controls (C405.2.1), occupancy sensors (C405.2.2.2), daylight zone controls (C405.2.2.3), specific application controls (0405.2.3), and commissioning of lighting controls per C405.13 New or moved lighting panel Provide all applicable lighting controls as noted for New Wring, automatic time switch controls (C405.2.2.1), and commissioning of IighUng controls per C405.13. Space is reconfigured - luminaires unchanged or moved only Provide all applicable lighting controls as noted for New Wiring and commissioning of lighting controls per C405.13. No changes are being made to the Interior lighting and space use not changed. ProjectAddress EURO PRODUCTS Date 2/19/2016 Lighting Alterations, Renovations & Building Additions For Building Department Use Less than 60% 60% or more Standalone Addition combined Clear fixtures replaced fixtures replaced bldg. addition w/exist 14 Notes: 1680 a. Lighting fixtures in a building addition may comply as a stand alone project, or they may be 3 combined with the overall existing bldg lighting to demonstrate compliance. Refer to CIO 1.4.3. 37 b. Fror retrofits and building additions, provide Space Types and gross inferior areas in the 4 Maximum Allowed Lighting table. If a builidng addition will comply as combined with the overall 148 eristing builidng, include all applicable existing Space Types and gross interior areas. 14 c. Dxument new fixtures and all existing to remain fixtures In the Proposed Lighting table. 516 d. Illess than 60% of existing fixtures will be replaced, provide total existing lighting wattage 3 (prior to refrofd) in the space provided in the Maximum Allowed Lighting fable. 95 Maximum Allowed Lighting Wattage Location (plan #, Allowed Gross Interior Watts Allowed room #) Space Type' Wads per fV Area in fP (walts#P x area) E4.00 Warehouse: Medium/bulky material 0.58 4355 2526 E4.00 Office -Open plan 0.98 1 966 947 DIMMING WTfH INGEGRAL OCCUPANCY CONTROL 25'-0" AFF LED 120 Retail Display Allowance from LTG4NT-DISPLAY ' Select Table 0405.5.2(2) category from drop down menu. •' For atriums, indicate height. Allowed wattage for first 40 feet is 0.03 IMM. ht., above 40 feet is 0.02 WIft. hL Proposed Lighting Wattage Area Allowed Watts Total 5321 3473 Location (plan #, room #) Fixture Description- Number of Fixtures Wafts/ Fixture Watts Proposed E4.00 C1-HIGHBAYLED, INTERGRALSENSORS 14 120 1680 C2 -WALL MOUNT 2' LED LUMINAIRE 3 12 37 C8.210', LED 4 37 148 CBD -2'x4', LEO, DIMMING, OCCIDAYLIGHT CTRLS 14 37 516 C9 - t'x4', LED 3 32 95 CIO .4"ROUND LED DOWNLIGHT 3 24 72 INTEGRAL XELEUM LIGHTING C1 DIMMING WTfH INGEGRAL OCCUPANCY CONTROL 25'-0" AFF LED 120 XDH120-40UY-120 3 Indicate lighting system automatic shut-off capability - identify lighting zone E4.0 4000K Retail Display Lighting from LTG4NT-DISPLAY areas served on plans; WALL MOUNT LUMINAIRE, LED, 2' NOMINAL Total Proposed Wads may not exceed Total Allowed Watts for Interior Lighting Total Proposed Watts I 2549 Include existing to remain lighting fixtures and exempt lighting equipment per notes below. Notes: 1. Inctide ALL proposed lighting fixtures. 2. Forproposed Fixture Description, indicate fixture type, lamp type (e.g. T-8), number oflamps in the fixture, and ballast type (d included). For track lighting, list the length of the track (in feet) in addition to the fixture, lamp, and ballast information. 3. Forproposed WaltsiFixture, use manufacturer's listed maximum input wattage of the fixture (not simply the lamp wattage) and othercriteria as specked in Section C405.5.1. Forline voltage track lighting, list the greater of actualluminafre wattage oriength of track multiplied by 50, or as applicable, the wattage of current limiting devices of the transformer. For low voltage track lighting list the transformerrated wattage. 4. Forlighting equipment eligible for exemption per C405.5.1, note exception number and leave WaffsfFixture blank. 5. Document existing to remain fixtures In Proposed Ughting fable In the same manner as new fixtures. Identify as existing in fixture description. 6. If #NA appears in Retail Display cells, information on LTG -INT -DISPLAY is incomplete. Interior Lighting Power Allowance COMPLIES it "no" is selected for any question, provide explanation: End of Lighting, Motor & Transformer Permit Documents Checklist REVIEWED F C®MPLIAIMCE WITH NFPA70 - ITEC FEB 2 4 2016 City of Tukwila BUILDING DIVISION RECEIVED CITY OF TUKWILA FEB 22 2016 PERMIT CENTER PORTLAND: 16790 NE MASON ST PORTLAND, OR 97230 503-331-0234 www.mckinstry.com PROJECT - EURO PRODUCTS 14570 INTERURBAN AVE S BUILDING C, SUITE #1 TUKWILA, WA 98168 CONSULTANTS: REGISTRATION: EXPIRES: 04/14/2016 ISSUES: 02/19/2016 ELEC. PERMIT SET NO. DATE DESCRIPTION McKINSTRY DMSION: ELECTRIC DESIGNED BY: PAUL HIGHLEY DRAWN BY: LPH CHECKED BY: PAUL HIGHLEY JOB NUMBER: 105823-001 DATE: 02/19/2016 SHEET TME: ELECTRICAL SCHEDULES SHEET NUMBER: 2012 Washington State Energy Code Compliance Fomes for Commercial Buildings including R2 & R3 over 3 stores and all Rt Revised Jan 2014 EURO PRODUCTS - LUMINAIRE SCHEDULE The following information is necessary to check a permit application for compliance with the lighting, motor, and transformer requirements in the Washington Slate Energy Code, Commercial TYPE DESCRIPTION MTG. LAMPS INPUTVA MFG. &CATALOG NUMBER NOTES (yes,no,na) COMBNATION EXIT SIGN / EMERGENCY LIGHTING UNIT CEILING INTEGRAL Location in Documents LITHONIA LIGHTING LIGHTING CONTROLS (Section C405.2) D(1 LED LIGHTING, GREEN LETTERS WALL LED 3 ECBG-LED-M6 1 C405.2.1.1 0405.2.1.2 PENDANT LUMINAIRE, LED, HI -BAY TYPE, 0-10V PENDANT INTEGRAL XELEUM LIGHTING C1 DIMMING WTfH INGEGRAL OCCUPANCY CONTROL 25'-0" AFF LED 120 XDH120-40UY-120 3 Indicate lighting system automatic shut-off capability - identify lighting zone E4.0 4000K areas served on plans; WALL MOUNT LUMINAIRE, LED, 2' NOMINAL WALL INTEGRAL Automatic time switch controls and override LiTHONIA LIGHTING NA C2 LENGTH, 1200 LUMENS LED 12.2 WL2-12L-LP840 1 Indicate locations where automatic shutoff is provided by other methods 4000K i GRID LUMINAIRE, 2'x4', LED GRID INTEGRAL XELEUM LIGHTING 0405.2.2.2 C8 Indicate on plans the locations served by occupancy sensors RECESSED LED 37 XATC24-M4OKU 4 Indicate vertical fenestration primary and secondary daylight zone areas on E4.00 4000K C405.2.2.3 fenestration and skylights plans, include sq. ft.; GRID LUMINAIRE, 2'x4', LED, INTEGRAL OCCUPANCY GRID INTEGRAL XELEUM LIGHTING C8D SENSOR AND DAYLIGHT HARVESTING RECESSED LED 37 XATC24-M40KU-XCO200 4 Yes C405.2.2.3.2 Daylight zone controls 4000K Indicate in plans the lighting load reduction (dimming) method -stepped or E4.00 FLANGE LUMINAIRE, 1'0, LED CEILING INTEGRAL XELEUM LIGHTING C9 continuous dimming RECESSED LED 31.5 XBTT14-M40KU Specific application lighting controls - General Indicate on plans the locations served by specific application lighting controls E4.00 4000K Indicate lighting control method for display and accent lighting, and display case RECESSED LUMINAIRE ROUND 4" DOWNLIGHT, LED GRID / CEILING INTEGRAL LITHONIA LIGHTING C10 NA RECESSED LED 24 EVO-40/20-4PR-MWD-LSS-277-EZ1-CRI90 1,2 1&2 lighting 4000K PROVIDE WITH'EU OPTION WHERE DESIGNATED AS EMERGENCY NOTES lighting and other lighting applications within the same space 1 LAUQE DEVORPPA RO NA 0405.2.3 - Item Hotegmotel guest rooms 2 VERIFY FINAL COLOR WITH ARCHITECT 3 Indicated whether lighting control is manual or automatic 3 EQUIPPPED WITH INTEGRATED OCCUPANCY / DAYLIGHT SENSOR NA C405.2.3 - Item Supplemental task lighting Provide automatic shut-off vacancy controls for supplemental task lighting, 4 PROVIDE WITH BATTERY PACK WHERE DESIGNATED AS EMERGENCY. BODINE BSL20 OR APROVED EQUAL 4 including under -shelf or under -cabinet lighting 5 Identify eligible non -visual applications and method of lighting control; 6 C405.2.3 - Item Lighting for non -visual it "no" is selected for any question, provide explanation: End of Lighting, Motor & Transformer Permit Documents Checklist REVIEWED F C®MPLIAIMCE WITH NFPA70 - ITEC FEB 2 4 2016 City of Tukwila BUILDING DIVISION RECEIVED CITY OF TUKWILA FEB 22 2016 PERMIT CENTER PORTLAND: 16790 NE MASON ST PORTLAND, OR 97230 503-331-0234 www.mckinstry.com PROJECT - EURO PRODUCTS 14570 INTERURBAN AVE S BUILDING C, SUITE #1 TUKWILA, WA 98168 CONSULTANTS: REGISTRATION: EXPIRES: 04/14/2016 ISSUES: 02/19/2016 ELEC. PERMIT SET NO. DATE DESCRIPTION McKINSTRY DMSION: ELECTRIC DESIGNED BY: PAUL HIGHLEY DRAWN BY: LPH CHECKED BY: PAUL HIGHLEY JOB NUMBER: 105823-001 DATE: 02/19/2016 SHEET TME: ELECTRICAL SCHEDULES SHEET NUMBER: 2012 Washington State Energy Code Compliance Fomes for Commercial Buildings including R2 & R3 over 3 stores and all Rt Revised Jan 2014 Project Address EURO PRODUCTS Date 2/19/2016 The following information is necessary to check a permit application for compliance with the lighting, motor, and transformer requirements in the Washington Slate Energy Code, Commercial Provisions. Applicability (yes,no,na) FCd. Section Component Compliance information required in permit documents Location in Documents Building Department Notes LIGHTING CONTROLS (Section C405.2) Indicate on plans the manual control type & locations served; E4.00 Yes C405.2.1.1 0405.2.1.2 Manual Interior IighUng controls Indicate of plans the 50% lighting load reduction method provided or identify E4.00 exception taken Indicate lighting system automatic shut-off capability - identify lighting zone E4.0 areas served on plans; Yes 0405.2.2.1 Automatic time switch controls and override Indicate locations of override switches on plans and the areas served, include NA switching area sq. ft.; Indicate locations where automatic shutoff is provided by other methods (occupancy sensor, daylight controls, etc) E4.00 Yes 0405.2.2.2 Occupancy sensors Indicate on plans the locations served by occupancy sensors E4.00 Daylight zones - Vertical Indicate vertical fenestration primary and secondary daylight zone areas on E4.00 Yes C405.2.2.3 fenestration and skylights plans, include sq. ft.; Indicate skylight daylight zone areas on plans, include sq. ft. E4.00 Indicate on plans the locations served by daylight zone controls; E4.00 Yes C405.2.2.3.2 Daylight zone controls Indicate in plans the lighting load reduction (dimming) method -stepped or E4.00 continuous dimming Yes C405.2.3 Specific application lighting controls - General Indicate on plans the locations served by specific application lighting controls E4.00 Indicate lighting control method for display and accent lighting, and display case lighting; NA 0405.2.3 -Items Display and accent 1&2 lighting Indicate these fixtures are controlled independently from both general area lighting and other lighting applications within the same space Provide a lighting control device at each guest room entry for all permanently NA 0405.2.3 - Item Hotegmotel guest rooms Installed fixtures in guest room; 3 Indicated whether lighting control is manual or automatic NA C405.2.3 - Item Supplemental task lighting Provide automatic shut-off vacancy controls for supplemental task lighting, 4 including under -shelf or under -cabinet lighting Identify eligible non -visual applications and method of lighting control; NA C405.2.3 - Item Lighting for non -visual 5 applications Indicate these fixtures are controlled independently from both general area lighting and other lighting applications within the same space Indicate lighting control method for lighting equipment for sale or demonstration; NA C405.2.3 - Item Lighting equipment for 6 sale or demonstration Indicate these fixtures are controlled independently from both general area lighting and other lighting applications within the same space If egress lighting power density is greater than 0.05W/f', indicate method of NIA Yes 0405.2.3 - Item Means of egress lighting automatic shut-off during unoccupied periods; 7 Identify on plans the egress fixtures that function as both normal and emergency means of egress illumination E4.00 0405.10 Provide vacancy device or timer to tum off fixtures within 15 minutes of NA C405.11 Cooler and freezer lighting unoccupancy for cooler and freezer lighting fixtures with lamp efficacy less than 40 lumens per watt NA 0405.2.4 Exterior lighting controls Indicate on exterior lighting plans the automatic lighting control method and locations served NA 0405.6.1 Exterior building grounds Provide motion sensor controls for building grounds fixtures rated at greater than lighting controls 100 watts with lamp efficacy less than 60 lumens, or identify exception taken Identify applicable commissioning documentation requirements per Section C408 or eligibility for exception; E4.00 Provide written procedures for functional testing of all automatic controls and E4.00 Yes 0408.3 Lighting system functional testing describe the expected system response; Identify in construction documents the party responsible for functional testing of automatic lighting controls E4.00 INTERIOR LIGHTING POWER & EFFICACY (Sections C405.5, C405.10, C405.11) Provide fixture schedule with fixture types, lamps, ballasts, and rated watts per fixture; E0.01 C405.5.1 Identify spaces eligible for lighting power exemption on plans and in compliance C405.5.1.1 Total connected Interior forms; NIA Yes C405.5.1.2 0405.5.1.3 lighting power Identify lighting equipment eligible for exemption in fixture schedule and in C405.5.1.4 compliance forms; NIA Indicate that exempt lighting equipment is in addition to general area lighting and NIA is controlled Independently Yes C405.4 Exit signs Provide exit sign types and rated watts per fixture In fixture schedule (maximum E0.01 5 watts per fixture) NA 0405.10 Cooler and freezer lighting For lighting in walk-in coolers and freezers, and refrigerated warehouse coolers C405.11 and freezers,lam rated rovide p p efficacy (in lumens per watt) in fixture schedule Lighting Power Calculation - Indicate compliance path taken Complete required compliance forms - proposed wattage per building area does No C405.5.2 Building Area Method not exceed maximum allowed wattage per building area. Identify locations of building areas on plans Complete required compliance forms -total proposed wattage does not exceed Yes C405.5.2 Space -By -Space Method maximum allowed wattage. Identify locations of space types on plans, including E4.00 retail display areas as applicable EXTERIOR LIGHTING POWER & EFFICACY (Section C405.6) Provide fixture schedule with fixture types, lamps, ballasts, and rated wafts per fixture; NA C405.6.2 Total connected exterior Identify exterior applications eligible for lighting power exemption on plans and in lighting power compliance forms; Indicate that exempt exterior lighting is controlled independently from non-exempt exterior lighting RA Table C405.6.2(1) Exterior lighting zone Indicate building exterior lighting zone as defined by the AHJ NA 0405.6.1 Exterior building grounds For building grounds fixtures rated at greater than 100 waft, provide rated lamp lighting efficacy (in lumens per watt) in fixture schedule NA C405.6.2 Exterior lighting power Complete required compliance form- proposed wattage for exterior lighting plus celwlations base site allowed does not exceed maximum allowed MOTORS & TRANSFORMERS (Sections C405.8, C405.9) NA 0405.8 Eiectr c Motors For motors not part of an HVAC system, provide electric motor schedule on electrical plans with hp, rpm, and rated efficiency NA 0405.9 Transformers Provide distribution transformer schedule on electrical plans with transformer size and efficiency it "no" is selected for any question, provide explanation: End of Lighting, Motor & Transformer Permit Documents Checklist REVIEWED F C®MPLIAIMCE WITH NFPA70 - ITEC FEB 2 4 2016 City of Tukwila BUILDING DIVISION RECEIVED CITY OF TUKWILA FEB 22 2016 PERMIT CENTER PORTLAND: 16790 NE MASON ST PORTLAND, OR 97230 503-331-0234 www.mckinstry.com PROJECT - EURO PRODUCTS 14570 INTERURBAN AVE S BUILDING C, SUITE #1 TUKWILA, WA 98168 CONSULTANTS: REGISTRATION: EXPIRES: 04/14/2016 ISSUES: 02/19/2016 ELEC. PERMIT SET NO. DATE DESCRIPTION McKINSTRY DMSION: ELECTRIC DESIGNED BY: PAUL HIGHLEY DRAWN BY: LPH CHECKED BY: PAUL HIGHLEY JOB NUMBER: 105823-001 DATE: 02/19/2016 SHEET TME: ELECTRICAL SCHEDULES SHEET NUMBER: EURO PROPERTIES LOAD DISTRIBUTION CKT CIRCUIT DESCRIPTION REC LTG EQPT HTG CLG 1.68 1 3 5 7 9 11 31 15 17 19 21 23 25 27 29 WAREHOUSE LIGHTING 0.56 OFFICE LIGHTING - LEVEL 1 0.37 OFFICE LIGHTING - LEVEL 2 AMPS SPARE 20 1 1.68 SPARE 20 1 0.37 SPARE 20 1 ERAPS 02 1 SPARE 20 1 SPARE 1.15 SPACE 1.98 2.15 SPACE 1.80 2.16 SPACE 2.16 2.16 SPACE DEMAND FACTORS RECEPTACLES LIGHTING EQUIPMENT HEATING COOLING SPACE 0.18 1 0.96 1 SPACE 4.86 2 4 6 8 10 12 14 16 18 20 22 24 26 28 30 RTU C100 4.86 22MCA 4.86 "' POLE SPARE AMPERES: VOLTS: PHASE: WIRE: BUS TYPE: A.I.C.: TYPE: MLO/MCB: MOUNTING: GND BUS: ISOLATED GND: 200% NEUTRAL: SPARE AMPS SPARE 20 1 1.68 SPARE 20 1 0.37 SPARE 20 1 SPARE 02 1 SPACE 20 1 SPACE 1.15 SPACE 1.98 2.15 PANEL L1 VIA XFMR 1.80 2.16 ' ' 2.16 2.16 ... LARGEST MOTOR (DEMAND AT 125%) kVA REMARKS: FEEDER DEMAND LOAD 30.25 kVA 36.5 AMPERES EURO PROPERTIES EXISTING PANEL H1 ...... ..... ....,. ... ... ... .... PH AMPS POLE LOAD kVA AMPERES: VOLTS: PHASE: WIRE: BUS TYPE: A.I.C.: TYPE: MLO/MCB: MOUNTING: GND BUS: ISOLATED GND: 200% NEUTRAL: 200A 480Y/277V 3 4 CU 42K MLO SURFACE YES NO NO AMPS A B C A B C A B C A B C A B 20 1 1.68 20 1 0.56 20 1 0.37 20 1 20 1 20 1 02 1 20 1 20 1 1 1.15 0.54 WAREHOUSE RECEPS 20 1 0.54 C WAREHOUSE RECEPS 20 1 0.90 0.72 DEMAND FACTORS RECEPTACLES LIGHTING EQUIPMENT HEATING COOLING NEC 220.44 125% 100% 100% 100% 0.18 1 0.96 1 MENS RESTROOM A 30:::,::::. ::::::::,3::::::::, ::::-:::::4.86::::::::. PANELTOTALCONN LOAD IN kVA ROOFTOP RECEPTACLE B C A B C SPARE 4.86 RECEPTACLES: LIGHTING: EQUIPMENT: HEATING: COOLING: 5.94 2.61 21.05 20 1 4.86 20 1 20 1 20 1 A B 20 1 SPARE TOTAL: 29.60 SPARE 20 1 C A 20 1 FEEDER TOTAL CONN LOAD IN kVA DEMAND LOAD DEMAND FACTORS RECEPTACLES NEC 220.44 LIGHTING 125% EQUIPMENT 100% HEATING 100% COOLING 100% B C A B C SPACE RECEPTACLES: LIGHTING: EQUIPMENT: HEATING: COOLING: 5.94 2.61 21.05 5.94 3.26 21.05 SPACE 100 3 4.13 3.96 4.32 SPACE TOTAL: 29.60 30.25 FEEDER DEMAND LOAD 30.25 kVA 36.5 AMPERES EURO PROPERTIES ...... ..... ....,. ... ... ... .... EXISTING PANEL L1 LOAD DISTRIBUTION CKT CIRCUIT DESCRIPTION PH AMPS POLE LOAD kVA AMPERES: VOLTS: PHASE: WIRE: BUS TYPE: A.I.C.: TYPE: MLO / MCB: MOUNTING: GND BUS: ISOLATED GND: 200% NEUTRAL: 200A 208Y/120V 3 4 CU 10K 200A MCB SURFACE YES NO NO REC LTG EQPT HTG CLG 1.15 1 3 5 7 1 9 11 13 15 17 19 21 23 25 27 29 31 33 35 37 39 41 OVERHEAD DOOR A B C A B C A B C A B C A B C A B C A B- C 20 1 1.15 0.54 WAREHOUSE RECEPS 20 1 0.54 0.90 WAREHOUSE RECEPS 20 1 0.90 0.72 WAREHOUSE RECEPS 20 1 0.72 0.18 1 0.96 1 MENS RESTROOM 20 1 1.14 0.18 0.96 WOMENS RESTROOM 20 1 1.14 ROOFTOP RECEPTACLE 20 1 SPARE 20 1 SPARE 20 1 SPARE 20 1 SPARE 20 1 SPARE 20 1 SPARE 20 1 SPARE 20 1 SPARE 20 1 DEMAND FACTORS RECEPTACLES NEC 220.44 LIGHTING 125% EQUIPMENT 100% HEATING 100% COOLING 100% SPACE SPACE SPACE SPACE SPACE ISPACE s. 00.1 2 4 6 8 10 12 1 14 16 18 20 22 24 26 28 30 32 34 36 38 40 42 .................::... REFER .:..: A B C A B C A B C A B C A B C A B C A B C 02 1 :.... .:::::: ... 00.1 PANEL TOTAL CONN AVk NI DAOL 1.20 KITCHEN RECEP 20 1 1.20 RECEPTACLES: LIGHTING: EQUIPMENT: HEATING: COOLING: 5.94 6.47 1.20 KITCHEN RECEP 20 1 1.20 0.54 LEVEL 1 OPEN OFFICE 20 1 0.54 0.54 LEVEL 1 OPEN OFFICE 20 1 0.54 0.54 LEVEL 1 OPEN OFFICE 20 1 0.54 0.72 1 1 LEVEL 2 OFFICES 20 1 0.72 TOTAL: 12.41 0.54 LEVEL 2 MEZZANINE 20 1 0.54 0.54 LEVEL 2 MEZZANINE 20 1 0.54 FEEDER TOTAL CONN LOAD IN kVA SPARE 20 1 SPARE 20 1 RECEPTACLES: 5.94 LIGHTING: EQUIPMENT: 6.47 HEATING: COOLING: SPARE 20 1 SPARE 20 1 SPARE 20 1 SPARE 20 1 SPACE TOTAL: 12.41 SPACE SPACE FEEDER DEMAND LOAD SPACE ISPACE 12.41 kVA 34.5 AMPERES ISPACE LARGEST MOTOR (DEMAND AT 125%) kVA REMARKS: DEMAND LOAD 5.94 6.47 12.41 BUILDING LOAD SUMMARY O TI SPACE C100 ------------- EXISTING METERED LOAD: 31KW g TL1 PER NEC 220.87: 1.25 X 31KW = 38.75KW 0 480-208Y/120VN r - rF_ - - J (r/�] 75KVA NEW /� W LOAD THIS SPACE: 30.25KW r ePANEL I r PANEL Y Hl o L1 NEW BUILDING SERVICE LOAD: 38.75KW+ 30.25KW = 69KW I LC100 11480Y/277V I- - - II - - 208Y/120V 69KW = 83.03A M ° " M L200A MLOJ 1#2G TO 4 L200A MCB J BLDG rq I I I STEEL L_ I _ I _ _ _ _ _ _ __j TI SPACE 0200 (VACANT) HOUSE PANELS - LOAD METERED: 35KW I o I I CN � I I TL2 r � I o I I o C) I I 480 208Y/120V N 75KVA r THL � �, M PANEL - PANEL I U L J r I F� I L J 480-208Y 120V u / � H2 L2 0 I r PANEL 15KVA r PANEL r M�', I I I I I- I 1480Y/277V -- d II k -- 208Y/120V HL I F u I HH L J I -- l 2F�: I I C200 m L u "J m 208Y 120V - - I - - 480Y 277V i - Y I ( I I - 1200A MLO I ` 1200A MCB I I I / m _ -i / I I HOUSE I I I I I r- L-- J 1#2G TO N L-- J 0 0 '+ BLDG I I 60A MCB I L - J M 1100A MLO I L_ I I I I STEEL L - - J 1#8G TO L J - BLDGM 1-1/4"-4#1- L f �- -c�- I� - 2"-4#3/0 STEEL I- - - - - - , - - + - - lN GND 140752AIC T + +-t- I I ALL EQUIPMENTAND LtJ FEEDERS ARE EXISTING - I 800A, 480Y/277V, BUSS I I GUTTER L- - - - - - - - - - - - r (x2) 4"-4#600 UTILITY FEEDER I I I WTR BLDG LIFER MAIN STEEL opsc ELECTRICAL SITE PLAN LE 3/32" = V- 0" 2 EXISTING ONE LINE DIAGRAM SCALE NONE i GENERAL NOTES 1. ELECTRICAL EQUIPMENT AND FEEDERS ARE EXISTING. NO ADDITIONAL PANELS, TRANSFORMERS THIS SCOPE OF WORK. 2. SPACE C100 AND C200 CURRENTLY VACANT (NO LOAD). SPACE C100 REMODEL IS CURRENT SCOPE OF WORK. 3. EXISTING LOAD OBTAINED FROM PSE UTILITY METER BILLS FOR 12 -MONTH TIME PERIOD. KEY NOTES 0 1. PANELS IN SPACE C100 UTILIZED FOR THIS SCOPE OF WORK. 4� • •, . +. , 11 NEC FEB 24 I[ � • NUMt: EURO PRODUCTS 14570 INTERURBAN AVE S BUILDING C, SUITE #1 TUKWILA, WA 98168 CONSULTANTS: REGISTRATION: EXPIRES: 04/14/2016 ISSUES: 02/19/2016 ELEC. PERMIT SET NO. DATE DESCRIPTION McKINSTRY DIVISION: ELECTRIC DESIGNED BY: PAUL HIGHLEY DRAWN BY- LPH CHECKED BY: PAUL HIGHLEY JOB NUMBER: 105823-001 DATE: 02/19/2016 SHEET TITLE: ELECTRICAL SITE PLAN ONE LINE DIAGRAM LOAD SUMMARY SHEET NUMBER: ...... ..... ....,. ... ... ... .... .... /� .. ... ...... .....:. .. ......:. ........ ..... .... ..... _._... ..;................... .. :.............. _ _ .... .. ...... .. ..: �::. .... ............_............ _... _................ .........._....._..............._ I CH € SUITE C100 - SCOPE OF WORK __ ,...._.............................. THIS PERMIT PACKAGE opsc ELECTRICAL SITE PLAN LE 3/32" = V- 0" 2 EXISTING ONE LINE DIAGRAM SCALE NONE i GENERAL NOTES 1. ELECTRICAL EQUIPMENT AND FEEDERS ARE EXISTING. NO ADDITIONAL PANELS, TRANSFORMERS THIS SCOPE OF WORK. 2. SPACE C100 AND C200 CURRENTLY VACANT (NO LOAD). SPACE C100 REMODEL IS CURRENT SCOPE OF WORK. 3. EXISTING LOAD OBTAINED FROM PSE UTILITY METER BILLS FOR 12 -MONTH TIME PERIOD. KEY NOTES 0 1. PANELS IN SPACE C100 UTILIZED FOR THIS SCOPE OF WORK. 4� • •, . +. , 11 NEC FEB 24 I[ � • NUMt: EURO PRODUCTS 14570 INTERURBAN AVE S BUILDING C, SUITE #1 TUKWILA, WA 98168 CONSULTANTS: REGISTRATION: EXPIRES: 04/14/2016 ISSUES: 02/19/2016 ELEC. PERMIT SET NO. DATE DESCRIPTION McKINSTRY DIVISION: ELECTRIC DESIGNED BY: PAUL HIGHLEY DRAWN BY- LPH CHECKED BY: PAUL HIGHLEY JOB NUMBER: 105823-001 DATE: 02/19/2016 SHEET TITLE: ELECTRICAL SITE PLAN ONE LINE DIAGRAM LOAD SUMMARY SHEET NUMBER: i 11 opsc ELECTRICAL SITE PLAN LE 3/32" = V- 0" 2 EXISTING ONE LINE DIAGRAM SCALE NONE i GENERAL NOTES 1. ELECTRICAL EQUIPMENT AND FEEDERS ARE EXISTING. NO ADDITIONAL PANELS, TRANSFORMERS THIS SCOPE OF WORK. 2. SPACE C100 AND C200 CURRENTLY VACANT (NO LOAD). SPACE C100 REMODEL IS CURRENT SCOPE OF WORK. 3. EXISTING LOAD OBTAINED FROM PSE UTILITY METER BILLS FOR 12 -MONTH TIME PERIOD. KEY NOTES 0 1. PANELS IN SPACE C100 UTILIZED FOR THIS SCOPE OF WORK. 4� • •, . +. , 11 NEC FEB 24 I[ � • NUMt: EURO PRODUCTS 14570 INTERURBAN AVE S BUILDING C, SUITE #1 TUKWILA, WA 98168 CONSULTANTS: REGISTRATION: EXPIRES: 04/14/2016 ISSUES: 02/19/2016 ELEC. PERMIT SET NO. DATE DESCRIPTION McKINSTRY DIVISION: ELECTRIC DESIGNED BY: PAUL HIGHLEY DRAWN BY- LPH CHECKED BY: PAUL HIGHLEY JOB NUMBER: 105823-001 DATE: 02/19/2016 SHEET TITLE: ELECTRICAL SITE PLAN ONE LINE DIAGRAM LOAD SUMMARY SHEET NUMBER: 2 4 22MCA TU 480/3 10 A30/3R/30A _ _ .. RTU UNIT LOCATED AT ROOFTOP H1-2,4,6 I" -3#10,1#10G L1-13 3/4"-3#10 i = 2 1 ELECTRICAL PLAN - MEZZANINE Z SCALE 1/4" = 1'- 0" GENERAL NOTES 1. FIELD COORDINATE FINAL WIRING DEVICE LOCATIONS. REFERENCE ARCHITECTURAL CASEWORK PLANS FOR DETAILS. 2. COORDINATE FINAL LUMINAIRE LOCATIONS WITH ARCHITECTURAL REFLECTED CEILING PLANS. 3. FOR ALLTELECOMM DEVICES INDICATED PROVIDE 1" EMPTY CONDUIT TO ABOVE ACCESSIBLE CEILING, TERMINATE WITH INSULATED THROAT BUSHING. IN AREAS WITH OPEN CEILING TERMINATE CONDUIT AT +11'-0" AFF AND TERMINATE WITH INSULATED THROAT BUSHING. LOW VOLTAGE CABLING AND SUPPORT BY OTHERS. 4. LIGHTING TO BE COMMISSIONED IN COMPLIANCE WITH CURRENTLY ADOPED WASHINGTON STATE ENERGY CODE. REFERENCE WSEC SECTION C408. 5. ELECTRICAL CONTRACTOR RESPONSIBLE FOR FUNCTIONAL TESTING OF LIGHTING CONTROL SYSTEM. LIGHTING SUPPLIER TO PROVIDE REQUIRED DOCUMENTATION AND PROCEDURES TO COMPLY WITH C408 FOR LIGHTING EQUIPMENT PROVIDED. KEY NOTES 0 1. EXISTING DEVICE SHOWN FOR REFERENCE. NO WORK REQUIRED. 2. OVERHEAD DOOR OPERATOR. COORDINATE FINAL LOCATION. CONTROLLER PROVIDED WITH UNIT, INSTALLED BY ELECTRICAL. 3. CONNECT TO UNSWITCHED LEG OF LIGHTING CIRCUIT. 4. CONNECTION TO INSTANT HOT WATER HEATER. UTILIZE CORD/PLUG INSTALLATION METHOD FOR DISCONNECTING MEANS. 5. COMBINATION WALL OCCUPANCY/DAYLIGHT/DIMMING CONTROL. WATTSTOPPER OR EQUAL. H 11TH �l i PROJECT: 1 astry Of Your Building SEATTLE: 5005 3RD AVENUE S PO BOX 24567 SEATTLE, WA 98124 1-800-669-6223 PORTLAND: 16790 NE MASON ST PORTLAND, OR 97230 503-331-0234 www.mckinstry.com EURO PRODUCTS 14570 INTERURBAN AVE S BUILDING C, SUITE #1 TUKWILA, WA 98168 CONSULTANTS: REGISTRATION: EXPIRES: 04/14/2016 ISSUES: 02/19/2016 ELEC. PERMIT SET NO. DATE DESCRIPTION McKINSTRY DMSION: ELECTRIC DESIGNED BY: PAUL HIGHLEY DRAWN BY: LPH CHECKED BY. PAUL HIGHLEY WILA JOB NUMBER: 105823-001 DATE: 02/19/2016 16 ITER SHEET TITLE: ELECTRICAL PLAN SHEET NUMBER: %mL tLtL,I I'(II.HL rLHIV — LEVEL 1 oz SCALE 1/4" = 1'- 0" 1 t"