Loading...
HomeMy WebLinkAboutPermit EL16-0198 - T-BAR INC - TENANT BUILD OUTT -BAR INC 14590 INTERURBAN AVE S EL16-0198 City of Tukwila Department of Community Development • 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Inspection Request Line: 206-438-9350 Web site: http://www.TukwilaWA.gov ELECTRICAL PERMIT Parcel No: 3365901630 Permit Number: EL16-0198 Address: 14590 INTERURBAN AVE S Issue Date: 3/22/2016 Permit Expires On: 9/18/2016 Project Name: T -BAR INC Owner: 2012 Name: SANFT LOUIE Address: 6120 52ND AVE 5, SEATTLE, WA, WA Cities Electrical Code: 98118 Contact Person: 2012 Name: SCOTT HUEBNER Address: 5005 THIRD AVE S, SEATTLE, WA, WA State Energy Code: 98134 Contractor: 2012 Name: MCKINSTRY CO LLC Address: PO BOX 24567, SEATTLE, WA, 98124 License No: MCKINCL942DN Lender: Name: Phone: (206) 832-8074 Phone: (206) 762-3311 Expiration Date: 3/15/2018 Address: , , , DESCRIPTION OF WORK: TI BUILD OUT, GENERAL PUPROSE POWER, FA ROUGH IN, TELE/DATA, A/ VROUGH IN MCKINSTRY JOB# 106206-001 Valuation of single family: $0.00 Fees Collected: $422.38 Valuation of mf/comm: $12,500.00 Type of Work: TENANT IMP Electrical Service Provided by: PUGET SOUND ENERGY Water District: TUKWILA Sewer District: TUKWILA SEWER SERVICE Current Codes adopted by the City of Tukwila: International Building Code Edition: 2012 National Electrical Code: 2014 International Residential Code Edition: 2012 WA Cities Electrical Code: 2014 International Mechanical Code Edition: 2012 WAC 296-4613: 2014 Uniform Plumbing Code Edition: 2012 WA State Energy Code: 2012 International Fuel Gas Code: 2012 Permit Center Authorized Signature: k Date: /OA� I hearby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this development perm' nd agree o e conditions attached to this permit. Signature: Date: j ZZ X1,6 Print Name: 5'C- C7 H L& C-- p 0 �� 6 This permit shall become null and void if the work is not commenced within 180 days for the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. PERMIT CONDITIONS: 1: 'ELECTRICAL PERMIT CONDITIONS' 2: A copy of the electrical work permit shall be posted or otherwise made readily accessible to the Electrical Inspector at each work site. 3: Approved plans shall be maintained at the construction site and shall be readily available to the Electrical Inspector. 4: All electrical work shall be in accordance with NFPA 70 - NEC, and requirements for electrical installations, Chapter 296-46B WAC. 5: When any portion of the electrical installation is to be hidden from view by permanent placement of parts of the building, such equipment shall not be concealed until it has been inspected and approved by the Electrical Inspector. 6: The issuance of an electrical work permit shall not be construed to be a permit for, or an approval of, any violation of the provisions of the electrical code or other ordinances of the jurisdiction. Permits or related documentation that presumes to grant this authority are therefore not valid. 7: Any change in the scope of work described by the electrical work permit shall require additional work permits. Where approved plans have been issued, revisions to the plans and additional review may be required. PERMIT INSPECTIONS REQUIRED Permit Inspection Line: (206) 438-9350 2100 ELECTRICAL FINAL 7003 ROUGH -IN ELECTRICAL 7002 SERVICE 7001 UNDERGROUND/SLAB CITY OF TUKWI A Community Development Department Permit Center 6300 Soutlicenter Blvd., Suite 100 Tuk-wila, WA 98188 b.9p://www.Tuk-%vilaWA.go v SITE LOCATION Electrical Permit No.� Project No. Date Application Accepted: ����- fo Date Application Expires: G (For _office use only) ELECTRICAL PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. "Please Print" King Co Assessor's Tax No.: -760,400 Site Address: 14590 Interurban Ave South Suite Number: B-100 Floor: Tenant Name: T -Bar Inc New Tenant: .....Yes No PROPERTY OWNER Name: Sanft, Louie Address: 6120 52nd Ave South City: Seattle State: WA Zip: 98118 CONTACT PERSON — person receiving all project communication Name: Scott Huebner / McKinstry Address: 5005 3rd Ave South City: Seattle State: WA Zip: 98134 Phone: (206) 920-6051 Fax: Email: scotthu@mckinstry.com ELECTRICAL CONTRACTOR INFORMATION Company Name: McKinstry Co LLC Address: 5005 3rd Ave S City: Seattle State: WA Zip: 98134 Phone: (206) 762-3311 Fax: Contr Reg No.: CCMCKINCL94 Exp Date: 03/16/2016 Tukwila Business License No.: BUS -0994320 Valuation of Project (contractor's bid price): $ 12,500 Scope of Work (please provide detailed information): TI Build out, General Purpose Power, FA Roughin, Tele/Data, A/V rough in McKinstry Job#106206-001 Job Site Contact: Jason Bogart 206-786-9339 or Brandon Kees 206-255-6104 Will service be altered? ❑ Yes ❑✓ No Type of Use: Warehouse / Office Type of work: ❑ New ❑ Addition ❑ Service Change 0 Low Voltage ❑ Generator 1Z Fire Alarm Property Served by: EZ Pugei Sound Energy ❑ Seattle City Light H: 'Applications Forms -Applications On Line\201 I Applications',Electrical Permit Application Revised 8-9-1 Ldocx Revised: August 2011 bh Adding more than 50 amps? ❑✓ Yes ❑ No ❑ Remodel JZ Tenant Improvement ❑ Telecommunication ❑ Temporary Service Page 1 of 2 RESIDENTIAL NEW RESIDENTIAL SERVICE ❑ New single family dwellings ...................................$152.85 (including an attached garage) ❑ Garages, pools, spas and outbuildings ........................ $81.90 ea ❑ Low voltage systems (alarm, furnace thermostat) ................................ $59.85 ea RESIDENTIAL REMODEL AND SERVICE CHANGES ❑ Service change or alteration ...................................... $81.90 ❑ (no added/altered circuits) $63.00 ❑ Service change with added/altered circuits ................. $81.90 ❑ number of added circuits ....................... $11.55 ea ❑ Circuits added/altered without service change ........... $54.60 ❑ (up to 5 circuits) $78.75 ❑ Circuits added/altered without service change ........... $54.60 (6 or more circuits) ............................................... $7.65 ea ❑ Meter/mast repair ....................................................... $68.25 ❑ Low voltage systems .................................................$59.85 (alarm, furnace thermostat) PERMIT APPLICATION NOTES - MULTI -FAMILY AND COMMERCIAL Fees are based on the valuation of the electrical contract Value of Construction — In all cases, a value of construction amount should be entered by,the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation The Building Official may grant one extension of time for an additional period not to exceed 90 days. The extension shall be requested in writing and justifiable cause demonstrated. I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. 1 1 llll 1141111c; Mailing Address: 5005 3rd Ave S H.',ApplicationstFortns-Applications On Linc\2011 ApplicationsTlectrical Permit Application Revised 8-9-1 Ldocx Revised: August 2011 bh Date: 03/04/2016 L,ay , Ctcpnune: (206) 920-6051 Seattle City WA 98134 State Zip Page 2 oft MISCELLANEOUS FEES ❑ Temporary service (residential) ................................. $63.00 ❑ Temporary service (generator) ................................... $78.75 ❑ Manufactured/mobile home service ........................... $84.00 (excluding garage or outbuilding) ❑ Carnivals.................................................................... $78.75 Number of concessions ......................... $10.50 ea Value of Construction — In all cases, a value of construction amount should be entered by,the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation The Building Official may grant one extension of time for an additional period not to exceed 90 days. The extension shall be requested in writing and justifiable cause demonstrated. I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. 1 1 llll 1141111c; Mailing Address: 5005 3rd Ave S H.',ApplicationstFortns-Applications On Linc\2011 ApplicationsTlectrical Permit Application Revised 8-9-1 Ldocx Revised: August 2011 bh Date: 03/04/2016 L,ay , Ctcpnune: (206) 920-6051 Seattle City WA 98134 State Zip Page 2 oft vERMIT COORQ COPY PLAN REVIEW/ROUTING SLIP PERMIT NUMBER: EL16-0198 DATE: 03/07/16 PROJECT NAME: T -BAR INC SITE ADDRESS: 14590 INTERURBAN AVE S X Original Plan Submittal Revision # before Permit Issued Response to Correction Letter # Revision # after Permit Issued DEPARTMENTS: 3-$ hWc '�--74 P Building Division 19 Fire Prevention ❑ Planning Division ❑ Public Works ❑ Structural ❑ Permit Coordinator PRELIMINARY REVIEW: DATE: 03/08/16 Not Applicable ❑ Structural Review Required ❑ (no approval/review required) REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: DUE DATE: 04/05/16 Approved ❑ Approved with Conditions Corrections Required ❑ Denied ❑ (corrections entered in Reviews) (ie: Zoning Issues) Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: 12/18/2013 DESCRIPTIONS PermitTRAK • QUANTITY PAID $490.63 EL16-0198 Address: 14590 INTERURBAN AVE S Apn: 3365901630 $422.38 ELECTRICAL $406.13 PLAN CHECK FEE R000.345.832.00.00 0.00 $81.23 PERMIT FEE MULTI-FAM/COMM R000.322.101.00.00 0.00 $324.90 TECHNOLOGY FEE $16.25 TECHNOLOGY FEE R000.322.900.04.00 0.00 $16.25 EL16-0199 Address: 14590 INTERURBAN AVE S Apn: 3365901630 $68.25 ELECTRICAL $65.00 PERMIT FEE MULTI-FAM/COMM R000.322.101.00.00 0.00 $65.00 TECHNOLOGY FEE $3.25 TECHNOLOGY FEE TOTAL:4. R000.322.900.04.00 0.00 $3.25 $490.63 Date Paid: Monday, March 07, 2016 Paid By: JIM THOMAS Pay Method: CREDIT CARD 001362 Printed: Monday, March 07, 2016 1:08 PM 1 of 1 SYSTEMS INSPECTION RECORD 2' Retain a copy with permit INSPECTION N0. PERMIT 4 0. CITY OF" TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Project: / Type of Inspection: i ( C' Address:85� 0 0 W96 Date Called: Special Instructions: Date Wanted: a. p.ni. Requester: Phone No: Id REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. INSPECTION RECORD Retain a copy with permit INSPECTION NO. PER N0. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Project: _7--r dU Type of Inspection: Address: %(,/� meq, l [/ km Date Called: Special Instructions: ,gypt4 koQ f �� R Date Wanted: a.m. Requester: PhoNo: FlApproved per applicable codes. Ll Corrections required prior to approval. u paid at 6300 Southcenter Blvd., Suite 100. Catl to schedule reinspection. INSPECTION RECORD -�' Retain a copy with permit INSPECTION N0, PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Project:j J�11 C— Type of Inspection Address: Z�!�LO ,�VK6 Date Called: Special Instructions. Date Wanted: a. E p:m. Requester: Phone No: F1 REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. MCKINSTRY CO LLC Home Espafiol Contact Safety & Health 45 Washington State Department of Labor & Industries MCKINSTRY CO LLC Page 1 of 3 Search L&I „.13Tt A -Z. Index Help My 1,&-i Claims & Insurance Workplace Rights Trades & Licensing Owner or tradesperson PO BOX 24567 KELLY, PETER SEATTLE, WA 98124 Principals 206-762-3311 ALLEN, DEAN KING County CHARLES,PARTNER/MEMBER KELLYP'962NQ MOORE, DOUGLAS J, PARTNER/MEMBER ALLEN, DAVID, PARTNER/MEMBER $4,000.00 TEPLICKY, JOSEPH W (BILL), PARTNER/MEMBER BLACK, STEPHEN, AGENT Effective date Doing business as MCKINSTRY CO LLC WA UBI No. Business type 602 569 922 Limited Liability Company License Verify the contractor's active registration / license / certification (depending on trade) and any past violations. Electrical Contractor _.................. Active. Meets current requirements. License specialties GENERAL License no. MCKINCL942DN Effective — expiration 03/15/2006— 03/15/2018 Designated administrator KELLY, PETER Active. Meets current requirements. License type License no. Master Electrician KELLYP'962NQ Bond ................. Western Surety Co $4,000.00 Bond account no. 929523050 Received by L&I Effective date 02/25/2011 03/06/2011 Expiration date Until Canceled Bond history .Savings .................... No savings accounts during the previous 6 year period. License Violations Infraction no. Satisfied -111-11.1-1 ............. https:Hsecure.Ini.wa.gov/verify/Detail.aspx?UBI=602569922&LIC=MCKINCL942DN&SAW= 03/14/2016 ELECTRICAL ABBREVIATIONS ABBREVIATION DESCRIPTION ABBREVIATION DESCRIPTION ABBREVIATION DESCRIPTION ABBREVIATION DESCRIPTION ABBREVIATION DESCRIPTION ABBREVIATION DESCRIPTION A AMP, AMPERES EPR ETHYLENE PROPYLENE RUBBER K THOUSAND NO. NUMBER SPEC SPECIFICATIONS UTP UNSHIELDED TWISTED PAIR AC 6" ABOVE COUNTER OR 3" ABOVE BACKSPLASH EQUIP EQUIPMENT KCMIL THOUSAND CIRCULAR MILS NO NORMALLY OPEN SQ SQUARE V VOLTS AF AMP FRAME EWC ELECTRIC WATER COOLER KV KILOVOLT NTS NOT TO SCALE SS STAINLESS STEEL VM VOLTMETER AFF ABOVE FINISHED FLOOR EWH ELECTRIC WATER HEATER KVA KILOVOLT -AMPERES OC ON -CENTER ST SHUNTTRIP or STREET W WATTS or WIRE AFG ABOVE FINISHED GRADE EXIST OR (E) EXISTING KVAR KILOVOLT -AMPERES REACTIVE OCPD OVERCURRENT PROTECTIVE DEVICE STD STANDARD W/ WITH AHU AIR HANDLING UNIT F FUSE OR FAHRENHEIT KW KILOWATTS OD OUTSIDE DIAMETER STL STEEL WH WATT-HOUR AIC AMPS INTERRUPTING CURRENT FA FIRE ALARM KWH KILOWATT-HOURS OFCI OWNER FURNISHED CONTRACTOR INSTALLED STRUCT STRUCTURAL WHSE WAREHOUSE AL ALUMINUM FACP FIRE ALARM CONTROL PANEL KWHD KILOWATT-HOUR DEMAND OL OVERLOADS SUB SUBSTITUTE WM WIREMOLD AT AMP TRIP FBO FURNISHED BY OTHERS LED LIGHT EMITTING DIODE OS OCCUPANCY SENSOR - ADJUSTABLE SV SOLENOID VALVE W/0 WITHOUT ATS AUTOMATIC TRANSFER SWITCH FC FOOTCANDLE LS LIMIT SWITCH PA PUBLIC ADDRESS SVC SERVICE WP WEATHERPROOF/NEMA 311 MINIMUM AUTO AUTOMATIC FLA FULL LOAD AMPERES LTG LIGHTING PB PULLBOX SW SWITCH X REACTANCE . AUX AUXILIARY FLEX FLEXIBLE CONDUIT LV LOW VOLTAGE PC PHOTOCELL- MOUNT FACING NORTH SWBD SWITCHBOARD XFMR TRANSFORMER AWG AMERICAN WIRE GAGE FS FLOW SWITCH M or MTR MOTOR PF POWER FACTOR SYM SYMMETRICAL XHHW MOISTURE AND HEAT RESISTANT BATT BATTERY FT FOOT or FEET MAX MAXIMUM PH OR 0 PHASE SYNC SYNCHRONOUS X CROSS-LINKED SYNTHETIC POLYMER BFC BELOW FINISHED CEILING FV FULLVOLTAGE MCA MINIMUM CIRCUIT AMPACITY PNL PANEL SYS SYSTEM XLP CROSS-LINKED POLYETHYLENE C CONDUIT or CENTIGRADE FVNR FULL VOLTAGE NON -REVERSING MC METAL CLAD CABLE PRI PRIMARY TB TERMINAL BLOCK XP EXPLOSION -PROOF CAT CATALOG FVR FULL VOLTAGE REVERSING MCB MAIN CIRCUIT BREAKER PSE PUGET SOUND ENERGY TD TIME DELAY Z IMPEDANCE CB CIRCUIT BREAKER G or GND GROUND MCC MOTOR CONTROL CENTER PT POTENTIAL TRANSFORMER TC TELECOMMUNICATIONS OUTLET (PHONE/DATA) o SUSPENDED LUMINAIRE CKT CIRCUIT GA GAGE MECH MECHANICAL PVC POLYVINYL CHLORIDE TEMP TEMPERATURE or TEMPORARY ❑-o POLE MOUNTED AREA LUMINAIRE CLG CEILING GEN GENERATOR MFR MANUFACTURER PWR POWER TERM TERMINAL TRACK LIGHTING CO CONDUIT ONLY - PROVIDE PULL STRING GFCI GROUND FAULT CIRCUIT INTERUPTER MH MANHOLE QTY QUANTITY THHN HEAT -RESISTANT THERMOPLASTIC INCLUDES ALL TRACK AND COMPONENTS CPT CONTROL POWER TRANSFORMER GRS GALVANIZED RIGID STEEL MIN MINIMUM R RESISTANCE or RADIUS THWN MOISTURE AND HEAT RESISTANT THERMOPLASTIC TC TIME CLOCK CT CURRENT TRANSFORMER HH HANDHOLE MISC MISCELLANEOUS REC CONVENIENCE RECEPTACLE TOS TOP OF SUPPORT or STEEL or SLAB PC PHOTOCELL CONTROL CU COPPER HID HIGH INTENSITY DISCHARGE MLO MAIN LUGS ONLY RECD REQUIRED TS TAMPER SWITCH DC DIRECT CURRENT HOA HAND -OFF -AUTO SELECTOR SWITCH MOCP MAXIMUM OVERCURRENT PROTECTION REV REVISION TSP TWISTED SHIELDED PAIR DIA DIAMETER HP HORSEPOWER MSB MAIN SWITCHBOARD -SERVICE ENTRANCE RATED RPM REVOLUTIONS PER MINUTE TTB TELEPHONE TERMINAL BOARD �p DISC DISCONNECT HPS HIGH PRESSURE SODIUM MTD MOUNTED RS RAPID START TC TELEPHONE TERMINAL CABINET DN DOWN HTR HEATER MTG MOUNTING RVAT REDUCED VOLTAGE AUTOTRANSFORMER TYP TYPICAL COMBINATION BATTERY POWERED EGRESS LIGHT AND EXIT DSB DISTRIBUTION SWITCHBOARD IBE INSTALLED/CONNECTED BY ELECTRICAL MVA MILLION VOLTAMPERES SCL SEATTLE CITY LIGHT UC UNDER -COUNTER LC ® LIGHTING CONTACTOR IN NEMA 1 ENCLOSURE, 120V COIL, DWG DRAWING IBO INSTALLED BY OTHERS N NEUTRAL SEC SECONDARY OF UNDER -FLOOR A/P A INDICATES CONTACT AMP RATING E EMERGENCY DESIGNATION IC INTERRUPTING CURRENT NC NORMALLY CLOSED SECT SECTION UG UNDERGROUND EF EXHAUST FAN ID INSIDE DIAMETER NEC NATIONAL ELECTRICAL CODE - JURISDICTION CURRENT SF SUPPLY FAN or SQUARE FEET UH UNIT HEATER 2 2 -POLE D DIMMER EL ELEVATION (HEIGHT) IN INCH or INCHES NEMA NATIONAL ELECTRICAL MANUFACTURERS ASSOCIATION SHLD SHIELD or SHIELDED UL UNDERWRITER LABORATORIES 4 -WAY P PILOT LIGHT EMT ELECTRICAL METALLIC TUBING INST INSTANTANEOUS NIC NOT IN CONTRACT SHT SHEET LION UNLESS OTHERWISE NOTED EOL END-OPLINE DEVICE JB orI-BOX JUNCTION BOX NL NIGHT LIGHT SK SKETCH UPS UNINTERRUPTABLE POWER SUPPLY TO BE SWITCHED SEPARATELY SYMBOLS (NOTE 1,2) SYMBOLS (NOTE 3) SYMBOLS (NOTE 3) SYMBOL DESCRIPTION SYMBOL DESCRIPTION SYMBOL DESCRIPTION REFERENCE LUMINAIRE SCHEDULE FOR DETAILS ON LUMINAIRES ALL RECEPTACLES TO BE GROUNDING TYPE LION MOUNTED AT+18" (NOTE 1) INCLUDING MOUNTING TYPE, HEIGHT, LAMPING, VOLTAGE, (NOTE 3) AFF LION. TYPE AS INDICATED MANUFACTURER, ETC. WP WEATHERPROOF GFCI GROUND FAULT CIRCUIT INTERRUPTER VARIOUS LIGHTING SYMBOLS ARE USED TO GENERALIZE XP EXPLOSION PROOF (NOTE 2) SHAPE/STYLE OF LUMINAIRE. REFERENCE LUMINAIRE SCHEDULE FOR DETAILS. I� SIMPLEX RECEPTACLE DUPLEX RECEPTACLE DELTA -WYE, DRY TYPE TRANSFORMER. VOLTAGE, KVA RATING AS GF1—LUMINAIRE DESIGNATION DOUBLE DUPLEX RECEPTACLE IN INDICATED ON PLANS, 150°C RISE, 220°C INSULATION CLASS STANDARD ® SPLIT WIRED DUPLEX RECEPTACLE 2a,b —CIRCUIT & SWITCHING SIMPLEX RECEPTACLE IN FLOOR BOX - FLUSH MOUNTED LEI ® DUPLEX RECEPTACLE IN FLOOR BOX - FLUSH MOUNTED PANEL SF1 BF� LXP2N 99MBRANCH CIRCUIT PANELBOARD. VOLTAGE, AMPACITY AS INDICATED. y ® DOUBLE DUPLEX RECEPTACLE IN FLOOR BOX - FLUSH MOUNTED 208Y/120 SF2 O SOLID LINETYPE INDICATES SURFACE, CEILING OR WALL MOUNTING ®100A SPLIT WIRED DUPLEX RECEPTACLE IN FLOOR BOX- FLUSH MOUNTED MCB WF� Sf3 ® CONNECTION TO PMENT SPECIFIED, FURNISHED XX,XXX AVAILABLE FAULT CURRENT AT NODE INDICATED FOWF2 AND INSTALLED BY OTHER TRADESELECTRICAL T X SPECIAL PURPOSE RECEPTACLE -TYPE AS NOTED XXKAIC AIC RATING OF EQUIPMENT GF1 RRi J U 6 POWER POLE WITH DIVIDER FOR TELECOMM WIRING 100/4 FEEDER DESIGNATION, REFER TO FEEDER SCHEDULE DASHED LINETYPE INDICATES RECESSED OR PARTIALLY RECESSED GF2 MOUNTING E �I J DEVICE OPERATOR PROVIDED BY OTHERS,INSTALLED BY ELECTRICAL f� TRANSFER SWITCH, SIZE, TYPE, POLES AS INDICATED ® MOTOR STARTER IN NEMA 1 ENCLOSURE, SIZE AS INDICATED, SFl GF1 X 3 -POLE LION F -� LUMINAIRE ON EMERGENCY SOURCE (TYPICAL) ®J COMBINATION MOTOR STARTER AND DISCONNECTTYPE AS SF2 RR1 W/X/Y/Z INDICATED, 3 -POLE LION GROUND FAULT SENSOR AND INDICATING LIGHT RR W STARTER SIZE X DISCONNECT RATING Y NEMA RATING m POTENTIAL TRANSFORMER FeEX1 OEX2 EXIT SIGN ON EMERGENCY SOURCE ARROW INDICATES DIRECTION OF EGRESS Z FUSES SHADING INDICATES FACE (SINGLE OR DOUBLE) -0�o-� FUSED DISCONNECT, TYPE AS INDICATED, 3 -POLE LION CURRENT TRANSFORMER X/Y/Z X DISCONNECT RATING o SUSPENDED LUMINAIRE Y NEMA RATING Z FUSE SIZE CUSTOMER METERING. PROVIDE METERING TO INDICATE VOLTAGE, AL1 CM AMPS, POWER FACTOR, KW, KVA. PROVIDE NECESSARY CT -S, PT'S AND RELATED EQUIPMENT. ❑-o POLE MOUNTED AREA LUMINAIRE NON-FUSED DISCONNECT, TYPE AS INDICATED, 3 -POLE LION X/Y X DISCONNECT RATING Y NEMA RATING UTILITY METERING. REFERENCE SERVING UTILITY STANDARDS FOR TRACK LIGHTING REQUIREMENTS. NUMBER OF HEADS AS SHOWN OR SPECIFIED INCLUDES ALL TRACK AND COMPONENTS n, MOTOR CONNECTION. MOTOR BY OTHERS. SIZE AS INDICATED BYLIGHTING CONTROL PANEL. PANEL TO MEET REQUIREMENTS OF MECHANICAL CALLOUT SYMBOL LCP I ADOPTED ENERGY CODE. REFERENCE LIGHTING CONTROL TC TIME CLOCK XX S MECHANICALCALLOUTSYMBOL. SCHEDULES e V/P XX EQUIPMENTTYPE FACP FIRE ALARM CONTROL PANEL. PC PHOTOCELL CONTROL YY EQUIPMENT DESIGNATION S SIZE(HP,MCA,FLA,KW) V/P VOLTAGE/PHASE OLV LINE VOLTAGE (120V) SMOKE DETECTOR OC OCCUPANCY SENSOR —xT MOTOR THERMAL OVERLOADS, SIZE PER MOTOR, (3) LION LCP LIGHTING CONTROL PANEL b CL CIRCUIT BREAKER, NUMBER INDICATES SIZE(A) AND POLES FIRE/SMOKE DAMPER. DAMPER BY OTHERS. �p CB ) LSIG ST SHUNTTRIP CJ BATTERY POWERED EMERGENCY LIGHT CL CURRENT LIMITING 1� RESIDENTIAL MEDIA DISTRIBUTION UNIT WITH INTEGRAL 30/3 L LONG TIME ADIUSTABILITY COIJVENIENCE OUTLET. S TIME COMBINATION BATTERY POWERED EGRESS LIGHT AND EXIT I INSTANTANEOUS ADIUSTABILITY INSTASHORNTANEOUS ADJUSTAY G GROUND FAULT ADIUSTABILITY LC ® LIGHTING CONTACTOR IN NEMA 1 ENCLOSURE, 120V COIL, KIRK KEY INTERLOCK 20/6 ELECTRICALLY HELD, NO/NC AUXILIARY CONTACTS A/P A INDICATES CONTACT AMP RATING �— FUSE, SIZE(A) AS INDICATED VARIABLE FREQUENCY DRIVE. SUPPLIED BY MECHANICAL. P INDICATES NUMBER OF POLES (NO) VFD COORDINATE INSTALLATION LOCATION. COORDINATE DISCONNECT T O THERMOSTAT, +60" AFF LION. UNIT CONTROLLED INDICATED. REQUIREMENT EITHER AT LINE SIDE OR LOAD SIDE DEPENDING ON S SWITCH, TYPE AS INDICATED, MOUNT+46" AFF LION VFD MANUFACTURER. 2 2 -POLE D DIMMER 3 3 -WAY LV LOW VOLTAGE 4 pB PULLBOX 4 -WAY P PILOT LIGHT 225A/3P K KEY SWITCH OC OCCUPANCY SENSOR M MOTOR RATED,SIZE OL PER MOTOR SIZE HH HANDHOLE,12"x18"x18" DEEP, FIBERGLASS WITH LID LABELLED 'ELECTRICAL' G E GEIIERATOR SET. SIZE AS INDICATED, MAIN BREAKER SIZE AS INDICATED. LION. DUAL LEVEL SWITCHING, INSIDE AND OUTSIDE LAMPS OF LUMINAIRE ® GROUND ROD. 3/4"X10' COPPER CLAD STEEL LION. TO BE SWITCHED SEPARATELY CIRCUITING SYMBOLS UNMARKED CIRCUIT IS CONCEALED IN CEILING OR WALL 1/2"-2#12,1#12G (LION) BEGINNING OF INDIVIDUAL CIRCUIT CONDUIT, STUBBED, CAPPED AND MARKED, WITH PULL STRING CONDUIT DOWN I CONDUIT UP CURRENT CARRYING CONDUCTORS NEUTRAL GROUNDING CONDUCTOR ISOLATED GROUND I FF11 LN1A-2,4,6 PANEL HOMERUN (3/4" MIN.) CIRCUIT 3/4"-3#12,1#12G EXISTING o-: �_ — �42 RACEWAY gUANTITY SIZE GF1 CONCEALED IN FLOOR CONDUCTORS -CONNECTED r j OR UNDER GROUND % 4a,b JUNCTION BOX SIZED —I—CONDUCTORS-NOT CONNECTED PER CODE PROJECT SCOPE 1. TENANT IMPROVEMENT IN'B100' SUITE OF EXISITNG BUILDING. INCLUDES ALL NEW LIGHTING AND RECEPTACLES. 2. ELECTRICAL SERVICE IS EXISTING AS WELL AS ALL PANELS/ TRANSFORMERS. INSTALLED UNDER PREVIOUS SCOPE OF WORK. i. c ..Z 11E12R^TE Pty IA -11T Fl.EQ—UIPED FOR: Li Mechan Oflumbin [9' Gas Pip CRY of Tukwga BIJIi_ONG DIVISION No chengeq shill I',!) made to the scope of prior approval of tj't�°¢i1Z Cuiitding Division, ;�i;e a rza:v plan submittal x:3;1 r'l y ir1c;L:do adclifionnai plan revleW fps. PORTLAND: 16790 NE MASON ST PORTLAND, OR 97230 503-331-0234 www.mckinstry.com PROJECT - INTERURBAN BUILDING B TENANT 1 14600 INTERURBAN AVE SOUTH TUKWILA, WA 98168 CONSULTANTS - REVIEWED FOR . C®IVIPLIANCE WITH NPPA 70 NEC MAR 112016 .\N7WV.,City of -Tukwila BUILDING DIVISION FILE COPY Permit wo...P L I (o - 6. 12 Pial-? roviow lapproval is subject to errors anti orl�iIDSiono. .A �',proval of c strudiion fi�tia ument.s droon �1 yt Bili -iloj the violai'D,- oi` a ny adoptod codF r ordinance. a ^',ecolpt of approvcdl Field Copy and c on('Limis is acknowledged: Fly . S.l Date: ��2z� d /,-- Cifrf of 3 bila BUILDING DIVISION SHEET INDEX EO.00 SYMBOLS AND ABBREVIATIONS EO.01 ELECTRICAL SCHEDULES E1.00 ONE LINE DIAGRAM / SITE PLAN / ELECTRICAL PANEL SCHEDULES E4.00 ELECTRICAL PLAN RECEIVED CITY OF TUKWILA MAR 0,7 2016 PERMIT CENTER REGISTRATION: EXPIRES: 04/14/2016 ISSUES: 03/04/2016 ELEC. PERMIT SET NO. DATE DESCRIPTION MCKINSTRY DIVISION: ELECTRIC DESIGNED BY. PAUL HIGHLEY DRAWN BY: LPH CHECKED BY. PAUL HIGHLEY JOB NUMBER: 106206-001 DATE: 03/04/2016 SHEET TITLE: SYMBOLS AND ABBREVIATIONS SHEET NUMBER: EO,00 2012 Washington State Energy Code Compliance Fors for Commercial Buildings including R2 & R3 over 3 stories and all R1 Revised Jan 2014 2012 Washington State Energy Code Compliance Fortes for Commercial Buildings including R2 & R3 over 3 stones and all R1 Project Info Project Address INTERURBAN BUILDINGS Dale 3/4/2016 Compliance forms 14600 INTERURBAN AVE SOUTH For Building Department Use do not require a password to use. 1800 BUILDING B, SUITE 100, TUKWILA, WA 98168 Applicant Name: MCKINSTRY COMPANY Instructional and 37 calculating cells are C1 Applicant Address: 5005 3RD AVE S, SEATTLE, WA write -protected. existing builidng, include all applicable existing Space Types and gross interior areas. 30 c. Document new fixtures and all existing to remain fixtures in the Proposed Lighting table. Applicant Phone: 206.832.8252 Project Description New Building Addition Alteration Lighting Compliance Path Lighting Power Density Calculations Total Building Performance Clear Maximum Allowed Lighting Wattage (If Total Building Performance then only LGT-CHK is required.) Lighting Power Allowance room #) Space Type* Watts per R' Method Building Area Method Space-BySpace Method Clear Selection required to E4.00 Office -Open plan 0.98 enable LPA forms exception taken - Interior Lighting System NEW LIGHTING FOR TENANT IMPROVEMENT IN 8100 SPACE. REMAINDER OF GUIDING IS UNOCCUPITED. Description P LIGHTING SYSTEM CONSISTS OF NEW LED LIGHTING FOR ALL INTERIOR SPACES WITH LOCAL I NETWORK Retail Display Allowance from LTG4NT•DISPLAY CONTROLS AS PRESCRIBED BY CODE. 1 FINAL LIGHTING CONTROL DRAWINGS TO BE PROVIDED BY LIGHTING CONTROL VENDOR. Briefly describe lighting system type and features. - - Additions and Change of Space Use (C101.4.3 & C101.4.4) Addition area or Change of Space Use area complies with all applicable provisions as stand alone project Addition area is combined with existing building lighting systems to demonstrate compliance with all applicable provisions per C101.4.3 Provide Building Area Method (LTG -INT -BLD) or Space -By -Space Method (LTG -INT -SPACE) Compliance Form. Document maximum allowed and proposed (including existing if applicable) lighting wattage ofAddition or Change of Use space. Provide applicable lighting controls per C405.2 and commissioning oflighting controls per C405.13. Alterations, Renovations and Repairs (0101.4.3.1) 60% or more of luminaires in space replaced Provide Building Area Method (LTG -INT -BLD) or Space -By -Space Method (LTG -INT -SPACE) Compliance Form. Document maximum allowed wattage within the lighting refrofit specs in Maximum Allowed Wattage table and proposed (including existing) lighting wattage in Proposed Wattage table. Retrofit and non -retrofit spaces shall be documented separately using multiple forms. Less than 60% of luminaires in space replaced Provide a separate Space -By -Space Method (LTG -INT -SPACE) Compliance Form for this retrofit area. Document existing total wattage within the lighting retrofit space in cell provdad in the Maximum Allowed Wattage table. Document proposed (including existing) lighting wattage in the Proposed Wattage fable. Lamp and/or ballast replacement within existing luminaires only -existing total interior building wattage not increased New wiring installed to serve added fixtures andfor fixtures relocated to new circuit Provide applicable manual lighting controls (C405.2.1), occupancy sensors (C405.2.2.2), daylight zone controls (C405.2.2.3), specific application controls (C405.2.3), and commissoning of lighting controls per C405.13 New or moved lighting panel Provide all applicable lighting controls as noted for New Wiring, automatic time switch controls (C405.2.2.1), and commissioning of lighting controls per C405.13. Space is reconfigured - luminaires unchanged or moved only Provide all applicable lighting controls as noted for New Wiring and commissioning of lighling controls per C405.13. No changes are being made to the interior lighting and space use not changed. EURO PRODUCTS - LUMINAIRE SCHEDULE aavi. d.ia 9me Project Address INTERURBAN BUILDING B Date 3/4/2016 snoitiddA gnidliuB & snoitavoneR,snoitaretlA gnithgiL esU lnemtrapeD gnidliuB roF Less than 60% 60% or more Standalone Addition combined Clear fixtures replaced fixtures replaced bldg. addition wlexist 15 Notes: 1800 a. Lighting fixtures in a building addition may comply as a stand alone project, or they may be 3 combined with the overall existing bldg lighting to demonstrate compliance. Refer to C101.4.3. 37 b. For retrofits and building additions, provide Space Types and gross interior areas In the C1 Maximum Allowed Lighting fable. If a builidng addition will comply as combined with the overall 25'-0" AFF existing builidng, include all applicable existing Space Types and gross interior areas. 30 c. Document new fixtures and all existing to remain fixtures in the Proposed Lighting table. 1110 d. If less than 60'1. of existing fixtures will be replaced, provide total existing lighting wattage 2 (prior to retrofit) in the space provided in the Maximum Allowed Lighting table. 63 Maximum Allowed Lighting Wattage Location (plan #, Allowed Gross Interior Watts Allowed room #) Space Type* Watts per R' Area in ft' (wattslft' x area) E4.00 Warehouse: Medlumlbulky materiel 0.58 3506 2033 E4.00 Office -Open plan 0.98 2169 2126 exception taken - C2 LENGTH, 1200 LUMENS LED Retail Display Allowance from LTG4NT•DISPLAY Select Table C405.5.2(2) category from drop down menu. For atriums, indicate height. Allowed wattage for first 40 feet is 0.03 WI t. ht., above 40 feet is 0.02 WIR. ht. Proposed Lighting Wattage Area Allowed Wafts Total 1 5675 1 4159 Location (plan #, room #) Fixture Description*" Number of Fixtures Watts/ Fixture Watts Proposed E4.00 Ct- HIGHBAY LED, INTERGRAL SENSORS 15 120 1800 C2- WALL MOUNT PLED LUMINAIRE 3 12 37 Code Section C1 DIMMING WITH INGEGRAL OCCUPANCY CONTROL 25'-0" AFF CBD -2'x4', LED, DIMMING, OCCIDAYLIGHT CTRLS 30 37 1110 C9 - t'x4', LED 2 32 63 Yes C405.2.1.1 0405.2.1.2 Manual interior lighting Indicate of plans the 50% lighting toad reduction method provided or Identify WALL MOUNT LUMINAIRE, LED, 2' NOMINAL WALL INTEGRAL LITHONIA LIGHTING exception taken - C2 LENGTH, 1200 LUMENS LED 12.2 WL2-12L-LP840 1 Retail Display Lighting from LTG -INT -DISPLAY - - Total Proposed Watts may not exceed Total Allowed Watts for Interior Lighting Total Proposed Watts I 3010 Include existing to remain lighting fixtures and exempt lighting equipment per notes below. Notes: 1. Include ALL proposed lighting fixtures. 2. For proposed Fixture Description, indicate fixture type, lamp type (e.g. T-6), number of lamps in the fixture, and ballast type (if included). For track lighting, list the length of the track (in feet) in addition to the fixture, lamp, and ballast Information. 3. For proposed WattvFbdure, use manufacturer's listed maximum input wattage of the fixture (not simply the lamp wattage) and other criteria as specified in Section C405.5.1. For line voltage track lighting, list the greater of actual luminaire wattage or length of track multiplied by 50, or as applicable, the wattage of current limiting devices of the transformer. For low voltage track lighting list the transformer rated wattage. 4. For lighting equipment eligible for exemption per C405.5.1, note exception number and leave Watts/Fixfu a blank. 5. Document existing to remain fixtures in Proposed Lighting table in the same manner as new fixtures. Identify as existing in fixture description. 6. If #NA appears in Retail Display cells, information on LTG -INT -DISPLAY is incomplete. Interior Lighting Power Allowance COMPLIES TYPE ! DESCRIPTION MTG. LAMPS INPUTVA I MFG. & CATALOG NUMBER NOTES j COMBNATION EXIT SIGN / EMERGENCY LIGHTING UNIT CEILING INTEGRAL LTTHONIA LIGHTING j EXI LED LIGHTING, GREEN LETTERS WALL LED 3 ECBG-LED-M6 1 PENDANT LUMINAIRE, LED, HI -BAY TYPE, 0-10V PENDANT INTEGRAL XELEUM LIGHTING Code Section C1 DIMMING WITH INGEGRAL OCCUPANCY CONTROL 25'-0" AFF LED 120 XDH120-40UY-120 3 Indicate on plans the manual control type & locations served; E4.00 4000K Yes C405.2.1.1 0405.2.1.2 Manual interior lighting Indicate of plans the 50% lighting toad reduction method provided or Identify WALL MOUNT LUMINAIRE, LED, 2' NOMINAL WALL INTEGRAL LITHONIA LIGHTING exception taken - C2 LENGTH, 1200 LUMENS LED 12.2 WL2-12L-LP840 1 4000K areas served on plans; Yea GRID LUMINAIRE, 2'x4', LED GRID INTEGRAL NA XELEUM LIGHTING C8 switching RECESSED LED 37 XATC24-M40KU 4 j 4000K I (occupancy sensor, daylight controls, etc) GRID LUMINAIRE, YxT, LED, INTEGRAL OCCUPANCY GRID INTEGRAL C405.2.2.2 XELEUM LIGHTING Indicate on plans the locations served by occupancy sensors C8D SENSOR AND DAYLIGHT HARVESTING RECESSED LED 37 XATC24-M40KU-XCO200 4 Yes C405.2.2.3 4000K plans, include sq. ft.; Indicate skylight daylight zone areas on plans, include sq. ft. FLANGE LUMINAIRE, 1'x4', LED CEILING INTEGRAL XELEUM LIGHTING C9 RECESSED LED 31.5 XBTT14-M40KU C405.2.2.3.2 Daylight zone controls 4000K Indicate in plans the lighting load reduction (dimming) method -stepped or RECESSED LUMINAIRE ROUND 4" DOWNLIGHT, LED GRID / CEILING INTEGRAL LITHONIA LIGHTING continuous dimming C10 RECESSED LED 24 EVO-40/20-4PR-MWD-LSS-277-EZI-CRI90 1,2 4000K Indicate lighting control method for display and accent lighting, and display case PROVIDE WITH'EU OPTION WHERE DESIGNATED AS EMERGENCY NOTES I LAUQE DEVORPPA RO 2 VERIFY FINAL COLOR WITH ARCHITECT i 3 EQUIPPPED WITH INTEGRATED OCCUPANCY / DAYLIGHT SENSOR 4 PROVIDE WITH BATTERY PACK WHERE DESIGNATED AS EMERGENCY. BODINE BSL20 OR APROVED EQUAL S 6 MAR 112016 -City, ®f -Tukwila pp r i/ xi �tt I k a For, yTwv T t 1 www.mckinstry.com PROJECT- INTERURBAN BUILDING B TENANT 1 14600 INTERURBAN AVE SOUTH TUKWILA, WA 98168 CONSULTANTS: REGISTRATION: EXPIRES: 04/14/2016 ISSUES: 03/04/2016 ELEC. PERMIT SET NO. DATE DESCRIPTION McKINSTRY DMSION: ELECTRIC DESIGNED BY: PAUL HIGHLEY DRAWN BY: LPH CHECKED BY: PAUL HIGHLEY JOB NUMBER: 106206-001 DATE: 03/04/2016 SHEET TITLE: ELECTRICAL SCHEDULES SHEET NUMBER: RECEIVED CITY CSE TUI�WILA MAR 07 2016 PERMIT CEITER 2012 Washington Stale Energy Code Compliance Forms for commercial Buildings including R2 & R3 over 3 stories and all R1 Revised Jan 2014 sserddAtcejorP B GNIDLIUB NABRURETNI etaD 6102/4/3 The following information is necessary to check a permit application for compliance with the lighting, motor, and transformer requirements in the Washington Slate Energy Code, Commerc Provisions. Applicability (yes,no,na) Code Section Component Compliance information required in permit documents Location in Documents Building Department Notes LIGHTING CONTROLS (Section C405.2) Indicate on plans the manual control type & locations served; E4.00 Yes C405.2.1.1 0405.2.1.2 Manual interior lighting Indicate of plans the 50% lighting toad reduction method provided or Identify centrals exception taken - E4.00 Indicate lighting system automatic shut-off capability - identify lighting zone E4.0 areas served on plans; Yea Cd05.2.2.1 Automatic time switch controls and override Indicate locations of override svdlches on plans and the areas served, include NA switching area sq. ft.; Indicate locations where automatic shutoff is provided by other methods (occupancy sensor, daylight controls, etc) E4.00 Yea C405.2.2.2 Occupancy sensors Indicate on plans the locations served by occupancy sensors E4.00 Daylight zones - Vertical Indicate vertical fenestration primary and secondary daylight zone areas on E4.00 Yes C405.2.2.3 fenestration and skylights plans, include sq. ft.; Indicate skylight daylight zone areas on plans, include sq. ft. E4.00 Indicate on plans the locations served by daylight zone controls; E4.00 Yes C405.2.2.3.2 Daylight zone controls Indicate in plans the lighting load reduction (dimming) method -stepped or continuous dimming E4.00 Yes C405.2.3 Specific application lighting controls - General Indicate on plans the locations served by specific application lighting controls E4.00 Indicate lighting control method for display and accent lighting, and display case lighting; KA 0405.2.3 -Items Display and accent 1&2 lighting Indicate these fixtures are controlled independently from both general area lighting and other lighting applications within the same space 0405.2.3 - Item Provide a lighting control device at each guest room entry for all permanently NA Hotel/motel guest rooms installed fixtures in guest room; Indicated whether lighting g g control is manual or automatic NA C405.2.3 - Item Supplemental task lighting Provide automatic shutoff vacancy controls for supplemental task lighting, 4 including under -shelf or under -cabinet lighting Identify eligible non -visual applications and method of lighting control; NA C405.2.3 -Item Lighting for non -visual 5 applications Indicate these fixtures are controlled independently from both general area lighting and other lighting applications within the same space Indicate lighting control method for lighting equipment for sale or demonstration; NA G405.2.3 - Item Lighting equipment for 6 sale or demonstration Indicate these fixtures are controlled independently from both general area lighting and other lighting applications within the same space If egress lighting power density is greater than 0.05WIfN, indicate method of Yes 0405.2.3 - Item Means of egress lighting automatic shutoff during unoccupied periods; NIA T Identify on plans the egress fixtures that function as both normal and emergency means of egress illumination E4.00 0405.10 Provide vacancy device or timer to tum off fixtures within 15 minutes of NA C405.11 Cooler and freezer lighting unoccupancy for cooler and freezer lighting fixtures with lamp efficacy less than 40 lumens per watt NA 0405.2.4 Exterior lighting controls Indicate on exterior lighting plans the automatic lighting control method and locations served NA 0405.6.1 Exterior building grounds Provide motion sensor controls for building grounds fixtures rated at greater than lighting controls 100 watts with lamp efficacy less than 60 lumens, or identify exception taken Identify applicable commissioning documentation requirements per Section C408 or eligibility for exception; E4.00 Provide written procedures for functional testing of all automatic controls and E4.00testing Yes 0408.3 Lighting system functional describe the expected system response; Identify in construction documents the party responsible for functional testing of automatic lighting controls E4.00 INTERIOR LIGHTING POWER & EFFICACY (Sections C405.5, C405.10, C405.11) Provide fixture schedule with fixture types, lamps, ballasts, and rated watts per fixture•, E0.01 C405.5.1 Identifys ll lighting paces eligible for 9 htin 9 Power exemption on plans and in complianceNIA 0405.5.1.1 Total connected interior forms; Yes C405.5.1.2 C405.5.1.3 lighting power Identify lighting equipment eligible for exemption in fixture schedule and in C405.5.1.4 compliance fortes; NIA Indicate that exempt lighting equipment is in addition to general area lighting and Is controlled independently NIA Yes 0405.4 Exit signs Provide exit sign types and rated watts per fixture in fixture schedule (maximum E0.01 5 watts per fixture) RA 0405.10 Cooler and freezer lighting For lighting in walk-in coolers and freezers, and refrigerated warehouse coolers C405.11 and freezers,lam efficacy rovide rated p p (in lumens per watt) in fixture schedule Lighting Power Calculation - Indicate compliance path taken Complete required compliance forms -proposed wattage per building area does No 0405.5.2 Building Area Method not exceed maximum allowed wattage per building area. Identify locations of building areas on plans Complete required compliance fors - total proposed wattage does not exceed Yes C405.5.2 Space -By -Space Method maximum allowed wattage. Identify locations of space types on plans, including E4.00 retail display areas as applicable EXTERIOR LIGHTING POWER & EFFICACY (Section C405.6) Provide fixture schedule with fixture types, lamps, ballasts, and rated watts per fixture; NA 0405.6.2 Total connected exterior Identify exterior applications eligible for lighting power exemption on plans and in lighting power compliance fors; Indicate that exempt exterior lighting is controlled Independently from non-exempt exterior lighting NA Table C405.6.2(1) Exterior lighting zone Indicate building exterior lighting zone as defined by the AHJ NA 0405.6.1 Exterior building grounds For building grounds fixtures rated at greaterthan 100 watts, provide rated lamp lighting efficacy (in lumens per watt) in fixture schedule NA C405.6.2 Exterior lighting power Complete required compliance for -proposed wattage for exterior lighting plus calculations base site allowed does not exceed maximum allowed MOTORS & TRANSFORMERS (Sections C405.8, C405.9) NA0405.8 Electric Motors For motors not part of an HVAC system, provide electric motor schedule on electrical plans with hp, rpm, and rated efficiency NA 0405.9 Transformers distribution transformer schedule on electrical plans with transformer size size and efficiency MAR 112016 -City, ®f -Tukwila pp r i/ xi �tt I k a For, yTwv T t 1 www.mckinstry.com PROJECT- INTERURBAN BUILDING B TENANT 1 14600 INTERURBAN AVE SOUTH TUKWILA, WA 98168 CONSULTANTS: REGISTRATION: EXPIRES: 04/14/2016 ISSUES: 03/04/2016 ELEC. PERMIT SET NO. DATE DESCRIPTION McKINSTRY DMSION: ELECTRIC DESIGNED BY: PAUL HIGHLEY DRAWN BY: LPH CHECKED BY: PAUL HIGHLEY JOB NUMBER: 106206-001 DATE: 03/04/2016 SHEET TITLE: ELECTRICAL SCHEDULES SHEET NUMBER: RECEIVED CITY CSE TUI�WILA MAR 07 2016 PERMIT CEITER B100 TENANT IMPROVEMENT EXISTING PANEL L1 LOAD DISTRIBUTION CKT CIRCUIT DESCRIPTION PH AMPS POLE LOAD kVA AMPERES: 200A VOLTS: 208Y/1 20V PHASE: 3 WIRE: 4 BUS TYPE: CU :.C.I.A K01 TYPE: MLO / MCB: 200A MCB MOUNTING: SURFACE GND BUS: YES ISOLATED GND: NO 200% NEUTRAL: NO REC LTG EQPT HTG CLG 1.15 1 3 5 7 9 11 13 15 17 19 21 23 25 27 29 31 33 35 37 39 41 OVERHEAD DOOR A B C A B C A B C A B C A B C A B C A B C 20 1 1.15 0.90 WAREHOUSE RECEPS 20 1 0.90 0.72 WAREHOUSE RECEPS 20 1 0.72 45.0 SPECER ESUGHERAW 02 1 45.0 0.18 0.96 MENS RESTROOM 20 1 1.14 0.18 0.96 WOMENS RESTROOM 20 1 1.14 0.18 ROOFTOP RECEPTACLE 20 1 0.18 SPARE 20 1 SPARE 20 1 SPARE 20 1 SPARE 20 1 SPARE 20 1 SPARE 20 1 SPARE 20 1 SPARE 20 1 DEMAND FACTORS RECEPTACLES NEC 220.44 LIGHTING 125% EQUIPMENT 100% HEATING 100% COOLING 100% SPACE SPACE SPACE SPACE SPACE SPACE ..............: ...................................................................................................................................................................................................................................................................................................................................................................... ......................................................................................................................................................................................................................................................................................................................................................................................................................................................... PANEL TOTAL CONN LOAD IN kVA 2 4 6 8 10 12 14 16 18 20 22 24 26 28 30 32 34 36 38 40 42 SPARE A B C A B C A B C A B C A B C A B C A B C 20 1 SPARE 20 1 RECEPTACLES: 6.12 LIGHTING: EQUIPMENT: 3.07 HEATING: COOLING: SPARE 20 1 0.54 LEVEL 1 OPEN OFFICE 20 1 0.54 0.36 LEVEL 1 OPEN OFFICE 20 1 0.36 0.54 LEVEL 1 OPEN OFFICE 20 1 0.54 0.54 LEVEL 2 MEZZANINE 20 1 0.54 TOTAL: 9.19 0.72 LEVEL 2 MEZZANINE 20 1 0.72 0.72 LEVEL 2 MEZZANINE 20 1 0.72 FEEDER TOTAL CONN LOAD IN kVA SPARE 20 1 SPARE 20 1 RECEPTACLES: 6.12 LIGHTING: EQUIPMENT: 3.07 HEATING: COOLING: SPARE 20 1 SPARE 20 1 SPARE 20 1 SPARE 20 1 SPACE TOTAL: 9.19 SPACE SPACE FEEDER DEMANDLOAD SPACE SPACE 9.19 kVA 25.5 AMPERES SPACE LARGEST MOTOR kVA (DEMAND AT 125%) REMARKS: DEMAND LOAD 6.12 3.07 9.19 BUILDING LOAD SUMMARY EXISTING METERED LOAD: 31KW PER NEC 220.87: 1.25 X 31KW = 3875KW NEW LOAD THIS SPACE: 30.25KW NEW BUILDING SERVICE LOAD: 38.75KW+ 30.25KW = 69KW 69KW = 83.03A \ - - - - (DTI SPACE B100 - HOUSE PANELS - LOAD METERED: 35KW CD 1 N L - - - - - - - - - - - - - - -- 1 � TL2 1 0 480-208Y/120V THL g N r: ,� I- - - -I 75KVA r - - I I (M� PANEL PANEL I 480-208Y/120V o 1 -F�' Y' H2 I f u, L2 I F_ -I 15KVA r - - -I r - -I o L T J 1480Y/277V -� II �- - - 208Y/120V PANEL PANEL y I I r ' I FQ { u LF J; I I C200 HL /2 L_ J I I I I I 1200A MLO I L J ^ I I I 1208Y/120V I - -II - - 480Y/277V I 200A MCB io 0 o I HOUSE I I L Ir J L --J 1 BLDGNL60A MCB I L - J m 1100A MLO I L I I - - - STEEL - - -� 1 L-- J 1#8G TO L-- J -1 I I 1 G zt L - - - - - - - - - - - - - - - - STEDEL m 1-1/4"-4#1- 1 -1 c� cp I- 2"-4#3/0 I N GND 40752AIC ALL EQUIPMENTAND L FEEDERS ARE EXISTING L - t - 600A, 480Y/277V, BUSS - - I I GUTTER L- - - - - - - - - - -- - (x2) 4"-4#350 UTILITY FEEDER I I I WTR BLDG LIFER MAIN STEEL 2 1 EXISTING ONE LINE DIAGRAM SCALE I NONE GENERAL NOTES 1. ELECTRICAL EQUIPMENT AND FEEDERS ARE EXISTING. NO ADDITIONAL PANELS, TRANSFORMERS THIS SCOPE OF WORK. 2. SPACE B100 IS CURRENTLY VACANT (NO LOAD). SPACE 8100 REMODEL IS CURRENT SCOPE OF WORK. 3. EXISTING LOAD OBTAINED FROM PSE UTILITY METER BILLS FOR 12 -MONTH TIME PERIOD. Mt' ! i ep u` "d SEATTLE: 5005 3RD AVENUE S PO BOX 24567 SEATTLE, WA 98124 1-800-669-6223 PORTLAND: 16790 NE MASON ST PORTLAND, OR 97230 503-331-0234 www.mckinstry.com KEY NOTES 1. PANELS IN SPACE B100 UTILIZED FOR THIS SCOPE OF WORK. PROJECT: MAR 112016 C*Ihf Of TU1C1�lI' Ri III himr. i ivvRinm 10 _ ELECTRICAL SITE PLAN Z SCALE 3/32" = 1' - 0" INTERURBAN BUILDING B TENANT 1 14600 INTERURBAN AVE SOUTH TUKWILA, WA 98168 CONSULTANTS: EXPIRES: 04/14/2016 ISSUES: 03/04/2016 ELEC. PERMIT SET NO. DATE DESCRIPTION mmmmmmmmmmmmmm McKINSTRY DIVISION: ELECTRIC DESIGNED BY: PAUL HIGHLEY DRAWN BY. LPH CHECKED BY: PAUL HIGHLEY JOB NUMBER: 106206-001 DATE: 03/04/2016 SHEET TITLE: ELECTRICAL SITE PLAN ONE LINE DIAGRAM LOAD SUMMARY RECEIVED CITY OF TUI�WIILA SHEET NUMBER: MAR u'7 Z016 10% 00 PERMIT ClEffr.111- R lS e' xY 2 1 ELECTRICAL PLAN - MEZZANINE z SCALE 1/4" = 1' - 0" GENERAL NOTES 1. FIELD COORDINATE FINAL WIRING DEVICE LOCATIONS. REFERENCE ARCHITECTURAL CASEWORK PLANS FOR DETAILS. 2. COORDINATE FINAL LUMINAIRE LOCATIONS WITH ARCHITECTURAL REFLECTED CEILING PLANS. 3. FOR ALLTELECOMM DEVICES INDICATED PROVIDE 1" EMPTY CONDUITTO ABOVE ACCESSIBLE CEILING, TERMINATE WITH INSULATED THROAT BUSHING. IN AREAS WITH OPEN CEILING TERMINATE CONDUIT AT +11'-0" AFF AND TERMINATE WITH INSULATED THROAT BUSHING. LOW VOLTAGE CABLING AND SUPPORT BY OTHERS. 4. LIGHTING TO BE COMMISSIONED IN COMPLIANCE WITH CURRENTLY ADOPED WASHINGTON STATE ENERGY CODE. REFERENCE WSEC SECTION C408. 5. ELECTRICAL CONTRACTOR RESPONSIBLE FOR FUNCTIONAL TESTING OF LIGHTING CONTROL SYSTEM. LIGHTING SUPPLIER TO PROVIDE REQUIRED DOCUMENTATION AND PROCEDURES TO COMPLY WITH C408 FOR LIGHTING EQUIPMENT PROVIDED. KEY NOTES 1. EXISTING DEVICE SHOWN FOR REFERENCE. NO WORK REQUIRED. 2. OVERHEAD DOOR OPERATOR. COORDINATE FINAL LOCATION. CONTROLLER PROVIDED WITH UNIT, INSTALLED BY ELECTRICAL. 3. CONNECT TO UNSWITCHED LEG OF LIGHTING CIRCUIT. 4. CONNECTION TO INSTANT HOT WATER HEATER. UTILIZE CORD/PLUG INSTALLATION METHOD FOR DISCONNECTING MEANS. 5. COMBINATION WALL OCCUPANCY/ DAYLIGHT/ DIMMING CONTROL. WATTSTOPPER OR EQUAL. REVIEWED FOR COMPLIANCE WITH NEPA 70 - NEC MAR 112016 City ®f�Tulckila BUILDING -DIVISION I v1stry Of Your Building SEATTLE: 5005 3RD AVENUE S PO BOX 24567 SEATTLE, WA 98124 1-800-669-6223 EURO PRODUCTS 14570 INTERURBAN AVE S BUILDING C, SUITE #1 TUKWILA, WA 98168 CONSULTANTS - Loin NO. DATE DESCRIPTION McKINSTRY DIVISION: ELECTRIC DESIGNED BY: PAUL HIGHLEY DRAWN BY: LPH CHECKED BY: PAUL HIGHLEY JOB NUMBER: 105823-001 DATE; 02/19/2016 SHEET TITLE: ELECTRICAL PLAN RECEIVED CITY OF TIUI(WILA SHEET NUMBER: MAR 07 2016