Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Permit EL16-0223 - INDIGO - SOUTHCENTER - TENANT IMPROVEMENT
INDIGO - SOUTHCENTER 17275 SOUTHCENTER PKWY 160 EL16-0223 City of Tukwila • Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Inspection Request Line: 206-438-9350 Web site: http://www.TukwilaWA.gov ELECTRICAL PERMIT Parcel No: 2623049063 Permit Number: EL16-0223 Address: 17275 SOUTHCENTER PKWY 160 Issue Date: 4/1/2016 Permit Expires On: 9/28/2016 Project Name: INDIGO - SOUTHCENTER Owner: Name: MASAO Address: 117 E LOUISA #230 C/O SCR LLC, Address: 7056 S 220TH ST, KENT, WA, 98032- 1910 License No: SEATAE1077RW Lender: Name: Address: DESCRIPTION OF WORK: Phone: (253) 867-2354 Phone: (253) 872-5553 Expiration Date: 12/17/2017 ELECTRICAL TI UTILIZING EXISTING 200A (2 -SECTION) PANEL INCLUDE THE REMOVAL, RELOCATION AND INSTALLATION OF ELECTRICAL SYSTEMS PERTAINING TO THE AFOREMENTIONED SCOPE OF WORK. Valuation of single family: $0.00 Fees Collected: $2,648.04 Valuation of mf/comm: $131,265.00 Type of Work: TENANT IMP Electrical Service Provided by: PUGET SOUND ENERGY Water District: TUKWILA Sewer District: TUKWILA SEWER SERVICE Current Codes adopted by the City of Tukwila: International Building Code Edition: SEATTLE, WA, 98102 Contact Person: 2014 Name: COREY MCKINNON Address: 7056 S 220 ST, KENT, WA, 98032 Contractor: 2012 Name: SEA TAC ELECTRIC INC Address: 7056 S 220TH ST, KENT, WA, 98032- 1910 License No: SEATAE1077RW Lender: Name: Address: DESCRIPTION OF WORK: Phone: (253) 867-2354 Phone: (253) 872-5553 Expiration Date: 12/17/2017 ELECTRICAL TI UTILIZING EXISTING 200A (2 -SECTION) PANEL INCLUDE THE REMOVAL, RELOCATION AND INSTALLATION OF ELECTRICAL SYSTEMS PERTAINING TO THE AFOREMENTIONED SCOPE OF WORK. Valuation of single family: $0.00 Fees Collected: $2,648.04 Valuation of mf/comm: $131,265.00 Type of Work: TENANT IMP Electrical Service Provided by: PUGET SOUND ENERGY Water District: TUKWILA Sewer District: TUKWILA SEWER SERVICE Current Codes adopted by the City of Tukwila: International Building Code Edition: 2012 National Electrical Code: 2014 International Residential Code Edition: 2012 WA Cities Electrical Code: 2014 International Mechanical Code Edition: 2012 WAC 296-466: 2014 Uniform Plumbing Code Edition: 2012 WA State Energy Code: 2012 International Fuel Gas Code: 2012 Permit Center Authorized Signature: Date: 2Y�/��� I hearby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this development permit and agree to the conditions attached to this permit. Signature: Date: q / Z�l Print Name:/ICL ��V/ii0 This permit shall become null and void if the work is not commenced within 180 days for the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. PERMIT CONDITIONS: 1: 'ELECTRICAL PERMIT CONDITIONS' 2: A copy of the electrical work permit shall be posted or otherwise made readily accessible to the Electrical Inspector at each work site. 3: Approved plans shall be maintained at the construction site and shall be readily available to the Electrical Inspector. 4: All electrical work shall be in accordance with NFPA 70 - NEC, and requirements for electrical installations, Chapter 296-46B WAC. 5: When any portion of the electrical installation is to be hidden from view by permanent placement of parts of the building, such equipment shall not be concealed until it has been inspected and approved by the Electrical Inspector. 6: The issuance of an electrical work permit shall not be construed to be a permit for, or an approval of, any violation of the provisions of the electrical code or other ordinances of the jurisdiction. Permits or related documentation that presumes to grant this authority are therefore not valid. 7: Any change in the scope of work described by the electrical work permit shall require additional work permits. Where approved plans have been issued, revisions to the plans and additional review may be required. PERMIT INSPECTIONS REQUIRED Permit Inspection Line: (206) 438-9350 2100 ELECTRICAL FINAL 7003 ROUGH -IN ELECTRICAL 7002 SERVICE 7001 UNDERGROUND/SLAB CITY OF TUKWI. Community Development Department Permit Center • 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 " http://www.TukwilaWA.gov Electrical Permit No. CJS Project No. Date Application Accepted: Date Application Expires: use ELECTRICAL PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. "Please Print" SITE LOCATION 17275 SOUTHCENTER PARKWAY King Co Assessor's Tax No.: Site Address: 17275 SOUTHCENTER PARKWAY Suite Number: Floor: Tenant Name: INDIGO- SOUTHCENTER New Tenant: ❑✓ .....Yes []..No PROPERTY OWNER Name: Address: City: State: Zip: CONTACT PERSON — person receiving all project communication Name: COREY MCKINNON Address: 705' S ;zg0.K -5 City: l State: WA Zip: 98032 Phone: (253) 872-5553 Fax: (253) 872-4112 Email: corey.mckinnon@seatacelectric.com Valuation of Project (contractor's bid price): $ 131,265 Scope of Work (please provide detailed information): ELECTRICAL CONTRACTOR INFORMATION Company Name: $ Address: 7 D 5-6 S , Z Z-0+"- S-{- City: `, 4;�. /v+ State: WA Zip: 98032 Phone: (253) 867-2354 Fax: (253) 872-4112 Contr Reg No.: Exp Date: 12/01/2015 Tukwila Business License No.: ELECTRICAL TI UTILIZING EXISTING 200A (2 -SECTION) PANEL INCLUDE THE REMOVAL, RELOCATION AND INSTALLATION OF ELECTRICAL SYSTEMS PERTAINING TO THE AFOREMTINOED SCOPE OF WORK. Will service be altered? ❑ Yes No Adding more than 50 amps? ❑✓ Yes ❑ No Type of Use: 4 Type of work: ❑ New ❑ Addition ❑ Service Change ❑ Remodel ® Tenant Improvement ❑ Low Voltage ❑ Generator ❑ Fire Alarm ❑ Telecommunication ❑ Temporary Service Property Served by: ® Puget Sound Energy ❑ Seattle City Light WApplicationsTorms-Applications On Line\201 I ApplicationsTlectrical Permit Application Revised 8-9-11.docx Revised: August 2011 bh Page] of 2 RESIDENTIAL NEW RESIDENTIAL SERVICE ❑ New single family dwellings ................................... $152.85 (including an attached garage) ❑ Garages, pools, spas and outbuildings ........................$81.90 ea ❑ Low voltage systems (alarm, furnace thermostat)................................$59.85 ea RESIDENTIAL REMODEL AND SERVICE CHANGES ❑ Service change or alteration ...................................... $81.90 (no added/altered circuits) ❑ Service change with added/altered circuits.................$81.90 number of added circuits ....................... $11.55 ea ❑ Circuits added/altered without service change ........... $54.60 (up to 5 circuits) ❑ Circuits added/altered without service change ........... $54.60 (6 or more circuits)...............................................$7.65 ea ❑ Meter/mast repair ....................................................... $68.25 ❑ Low voltage systems ................................................. $59.85 (alarm, furnace thermostat) PERMIT APPLICATION NOTES - MULTI -FAMILY AND COMMERCIAL Fees are based on the valuation of the electrical contract. MISCELLANEOUS FEES ❑ Temporary service (residential) ................................. $63.00 ❑ Temporary service (generator) ................................... $78.75 ❑ Manufactured/mobile home service ........................... $84.00 (excluding garage or outbuilding) ❑ Carnivals.................................................................... $78.75 Number of concessions ......................... $10.50 ea Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The Building Official may grant one extension of time for an additional period not to exceed 90 days. The extension shall be requested in writing and justifiable cause demonstrated. I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. Signature: Print Name:—r&()tj Mailing Address: 7056 S. 220TH STREET H:\Applications\Forms-Applications On Line\2011 Applications\Electrical Permit Application Revised 8-9-11.docx Revised: August 2011 bh Date: 3/11/2016 Day Telephone: (253) 872-5553 KENT WA 98032 City state Zip Page 2 of 2 DESCRIPTIONS ACCOUNT QUANTITY PermitTRAK PAID $2,648.04 EL16-0223 Address: 17275 SOUTHCENTER PKWY 160 Apn: 2623049063 $2,648.04 ELECTRICAL $2,546.19 PLAN CHECK FEE R000.345.832.00.00 0.00 $509.24 PERMIT FEE MULTI-FAM/COMM R000.322.101.00.00 0.00 $2,036.95 TECHNOLOGY FEE $101.85 TECHNOLOGY FEE R000.322.900.04.00 0.00 TOTAL FEES PAID .. $101.85 0, Date Paid: Monday, March 14, 2016 Paid By: THOMAS HARGRAVES Pay Method: CREDIT CARD 014102 Printed: Monday, March 14, 2016 11:31 AM 1 of 1 (rT�2I SYSTEMS oz - INSPECTION RECORD Retain a copy with permit VIS INSPECTION N0. P RMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Project: Type of Inspection: , Address:�� ��.� ; R. Date Called: Special Instructions: Date Wanted: ('. a.m 0 .m. Requester: Phone No: T 73 Z' " paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. INSPECTION RECORD19 Retain a copy with permit CV(' -0 1' INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431-3670 (inspector: [ ` 71,4 h1l;VAIA IDate: I:?/a I� i, $58.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to sechedule reinspection. Receipt No.: I Date: INSPECTION RECORD Retain a copy with permit INSPEUTION N0. PERMIT N0. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Project: /A&L'o Type of Inspection: V� Address: ✓ Date Called: Special Instructions: Date Wanted:a.m a Requester: - t Phone No: u 1 ri— Approved per applicable codes. 11 Corrections required prior to approval. U paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. INSPECTION RECORD3 �G Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Project: Type of Inspection: p Address: / Date Called: Special Instructions: l� © Date Wanted: IV a. Requester: Phone No: Q 77Y2— Approved per applicable codes. L: Corrections required prior to approval. F] REINSPECTION �EE REQUIRED. Prior to next inspection: fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. INSPECTION RECORD Retain a copy with permit 16'1 2� INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Approved per applicable codes. 11 Corrections required prior to approval. `J paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. t INSPECTION RECORD Retain a copy with permit ig INSPECTION N0. PE M CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-367 Permit Inspection Request Line (206) 438-9350 Project:, �.; (116- �i l.^ Type of Inspe tcJt'�-✓ 1 cJ ' Address: /A-75"SDate Callecy Special Instructions: / .-160 Date Wanted: a. to p.m. Requester: 1� Phone No: V 170 Approved per applicable codes. 11 Corrections required prior to approval. I___1 paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. 2012 Washington State Energy Code Compliance Forms for Commercial Buildings including R2 & R3 over 3 stories and all R1 Revised Jan 2014 Project Info Project Address INDIGO-SOUTHCENTER Date 5/21/2013 Compliance 17275 SOUTHCENTER PARKWAY - SUITE 160 For Building Department Use forms do not require a TUKWILA, WA 98188 password to use. , Applicant Name: PP SEA -TAC ELECTRIC, INC. Instructional andI calculating cells , Ll Applicant Address: 7056 S 220TH STREET -KENT, WA 98032 Applicant Phone: (253) 872-5553 are write- Froject Description ❑ New Building [:]Addition ❑� Alteration ❑ Plans Included Lighting Compliance Path Lighting Power Density Calculations Q Total Building Performance (If Total Building Performance then only LGT-CHK is required.) Lighting Power Allowance QQ Building Area Method Q Spa e D R Method Selection required to V W' I H eff�ICE enable LPA forms Interior Lighting System ELECTRICAL TENANT IMPROVEMENT Description MAR 2 5 2016 Briefly describe lighting C*Ky of Tultwila system type and features. BUILDING DIVISION Additions and Change of Space Use (C101.4.3 & C101.4.4) ❑ Addition area or Change of Space Use area complies with all applicable provisions as stand alone project ❑ Addition area is combined with existing building lighting systems to demonstrate compliance with all applicable provisions per C101.4.3 Provide Building Area Method (LTG -INT -BLD) or Space -By -Space Method (LTG -INT -SPACE) Compliance Form. Document maximum allowed and proposed (including existing if applicable) lighting wattage of Addition or Change of Use space. Provide applicable lighting controls per C405.2 and commissioning of lighting controls per C405.13. Alterations, Renovations and Repairs (C101.4.3.1) ❑ 60% or more of luminaires in space replaced Provide Building Area Method (LTG -INT -BLD) or Space -By -Space Method (LTG -INT -SPACE) Compliance Form. Document maximum allowed wattage within the lighting retrofit space in Maximum Allowed Wattage table and proposed (including existing) lighting wattage in Proposed Wattage table. Retrofit and non -retrofit spaces shall be documented separately using multiple forms. ❑ Less than 60% of luminaires in space replaced Provide a separate Space -By -Space Method (LTG -INT -SPACE) Compliance Form for this retrofit area. Document existing total wattage within the lighting retrofit space in cell provided in the Maximum Allowed Wattage table. Document proposed (including existing) lighting wattage in the Proposed Wattage table. ❑ Lamp and/or ballast replacement within existing luminaires only — existing total interior building wattage not increased ❑ New wiring installed to serve added fixtures and/or fixtures relocated to new circuit Provide applicable manual lighting controls (C405.2.1), occupancy sensors (C405.2.2.2), daylight zone controls (C405.2.2.3), specific application controls (C405.2.3), and commissioning of lighting controls per C405.13 ❑ New or moved lighting panel Provide all applicable lighting controls as noted for New Wiring, automatic time switch controls (C405.2.2.1), and commissioning of lighting controls per C405.13. ❑ Space is reconfigured - luminaires unchanged or moved only Provide all applicable lighting controls as noted for New Wiring and commissioning of lighting controls per C405.13. ❑ No changes are being made to the interior lighting and space use not changed. RECEIVtt in rs tL-16- 0 zZ3 VILA NIAR 14 2016 PERMIT CENTER 2012 Washington State Energy Code Compliance Forms for Commercial Buildings including R2 & R3 over 3 stories and all R1 Revised Jan 2014 Project Address INDIGO • SOUTHCENTER Date 5/21/2013 Lighting Alterations, Renovations & Building Additions O Less than 60% O 60% or more Stand alone O Addition Notes: a. Lighting fixtures in a building addition may comply as a stand alone project, or they may be combined with the overall existing bldg lighting to demonstrate compliance. Refer to C101.4.3. b. For retrofits and building additions, provide Building Area types and gross interior areas in the Maximum Allowed Lighting table. If a builidng addition will comply as combined with the overall existing builidng, include all applicable existing Building Area types and gross interior areas. c. Document new fixtures and all existing to remain fixtures in the Proposed Lighting table. d. If less than 60% of existing fixtures will be replaced, use LTG -INT -SPACE form. For Building Department Use Maximum Allowed Lighting Wattage Location (plan #, owe Building Area* room #, or ALL) Area Description Watts per ft2 ross Interior a s owe Area in ft2 (watts/ft2 x area) Office E3.01 OFFICE BUILDING 0.90 3519 3167 245 Office FIX 7 35 245 Office F2 * Select Table C405.5.2(1) Building Area from drop down menu. Totall 3519 Proposed Lighting Wattage Building Area* Location (plan #, room #) Fixture Description** Number of Fixtures Watts/ Fixture Watts Proposed Office F1 7 35 245 Office FIX 7 35 245 Office F2 1 79 79 Office F3 4 30 120 Office F4 2 19 38 Office F5 6 16 96 Office Fe 31 35 1085 Office F7 4 70 280 Office F7X 3 70 210 Office F8X 2 35 70 Office F9X 2 18 36 Office I XII 2 1 5 1 10 * Select Table C405.5.2(1) Building Area from drop down menu. ** Include existing to remain lighting and exempt lighting equipment per notes below. Compliance by Building Area Building Area Warnings Total Allowed Watts Total Proposed Watts Interior Lighting Power Allowance Office 3167 2514 COMPLIES Total 3167 1 2514 Notes: 1. Proposed Wattage for each Building Area type shall not exceed the Allowed Wattage for that Building Area type. Trading wattage between Building Area types is not allowed under the Building Area Method compliance path. 2. Proposed fixtures must be listed in the building area in which they occur. Include ALL proposed lighting fixtures. 3. For proposed Fixture Description, indicate fixture type, lamp type (e. g. T-8), number of lamps in the fixture, and ballast type (if included). For track lighting, list the length of the track (in feet) in addition to the fixture, lamp, and ballast information. 4. For proposed Watts/Fixture, use manufacturer's listed maximum input wattage of the fixture (not simply the lamp wattage) and other criteria as specified in Section C405.5.1. For line voltage track lighting, list the greater of actual luminaire wattage or length of track multiplied by 50, or as applicable, the wattage of current limiting devices or of the transformer. For low voltage track lighting list the transformer rated wattage. 5. For lighting equipment eligible for exemption per C405.5.1, note exception number and leave Watts/Fixture blank. o. Vocpmenr existing to remain nxrures in r ea ugnrnng raoie in me same manner as new nxrur� enury as existing in nxrure aescnpnon. Agh Ah Ug'hting, Motor, and Traii'sformer Permit Documents"-�;hecklist LTG -CHK 2012 Washington State Energy Code Compliance Forms for Commercial Buildings including R2 8 R3 over 3 stories and all R1 Revised Jan 2014 Project Address INDIGO - SOUTHCENTER Date 5/21/2013 The following information is necessary to check a permit application for compliance with the lighting, motor, and transformer requirements in the Washington State Energy Code, Commercial Provisions. Applicability Location in Building Department (yes ,no,na) Code Section Component Compliance information required in permit documents Documents Notes LIGHTING CONTROLS (Section C405.2) C405.2.1.1 Manual interior Indicate on plans the manual control type & locations served; E3.01 Indicate of plans the 50% lighting load reduction method E3.01 Yes C405.2.1.2 lighting controls provided or identify exception taken Indicate lighting system automatic shut-off capability - identify E3.01 lighting zone areas served on plans; Yea 0405.2.2.1 Automatic time switch controls and Indicate locations of override switches on plans and the areas E3.01 override switching served, include area sq. ft.; Indicate locations where automatic shutoff is provided by other E3.01 methods (occupancy sensor, daylight controls, etc) Yes 0405.2.2.2 Occupancy sensors Indicate on plans the locations served by occupancy sensors E3.01 Daylight zones - Indicate vertical fenestration primary and secondary daylight E3.01 Yes 0405.2.2.3 Vertical fenestration zone areas on plans, include sq. ft.; and skylights Indicate skylight daylight zone areas on plans, includes . ft. N/A Daylight zone Indicate on plans the locations served by daylight zone controls; E3.01 Yes 0405.2.2.3.2 controls Indicate in plans the lighting load reduction (dimming) method - stepped or continuous dimming E6.01 Specific application Indicate on plans the locations served by specific application NA C405.2.3 lighting controls - lighting controls General Indicate lighting control method for display and accent lighting, and display case lighting; ;w1P, 0405.2.3 - Items 1&2 Display and accent lighting Indicate these fixtures are controlled independently from both general area lighting and other lighting applications within the same space 0405.2.3 - Hotel/motel guest Provide a lighting control device at each guest room entry for all NA Item 3 rooms permanently installed fixtures in guest room; Indicated whether lighting control is manual or automatic ZIP, C405.2.3 - Supplemental task Provide automatic shut-off vacancy controls for supplemental Item 4 lighting task lighting, including under -shelf or under -cabinet lighting Identify eligible non -visual applications and method of lighting control; ;•IP, 0405.2.3 - Item 5 Lighting for non- visual applications Indicate these fixtures are controlled independently from both general area lighting and other lighting applications within the same space Indicate lighting control method for lighting equipment for sale 0405.2.3 - Lighting equipment or demonstration; Indicate these fixtures are controlled independently from both NA Item 6 for sale or demonstration general area lighting and other lighting applications within the same space If egress lighting power density is greater than 0.05W/ft2, C405.2.3 - Means of egress indicate method of automatic shut-off during unoccupied E3.01 Yes Item 7 lighting periods; Identify on plans the egress fixtures that function as both E3.01 normal and emergency means of egress illumination 040510 Cooler and freezer Provide vacancy device or timer to turn off fixtures within 15 xa . C405.11 lighting minutes of unoccupancy for cooler and freezer lighting fixtures with lamp efficacy less than 40 lumens per watt NA C405.2.4 Exterior lighting Indicate on exterior lighting plans the automatic lighting control controls method and locations served Exterior building Provide motion sensor controls for building grounds fixtures xa C405.6.1 grounds lighting rated at greater than 100 watts with lamp efficacy less than 60 controls lumens, or identify exception taken Identify applicable commissioning documentation requirements N/A per Section C408 or eligibility for exception; Provide written procedures for functional testing of all automatic N/A Yes 0408.3 Lighting system functional testing controls and describe the expected system response; Identify in construction documents the party responsible for E3.01 functional testing of automatic lighting controls INTERIOR LIGHTING POWER $ EFFICACY Sections C405.5, C405.10, C405.11 Provide fixture schedule with fixture types, lamps, ballasts, and E0.04 �,�� rated watts per fixture; Ak tidhting, Motor, and Triatisformer Permit Documents-l"hecklist LTG -CHP? 2012 Washington State Energy Code Compliance Forms for Commercial Buildings including R2 & R3 over 3 stories and all R1 Revised Jan 2014 Project Address INDIGO - SOUTHCENTER Date 5/21/2013 The following information is necessary to check a permit application for compliance with the lighting, motor, and transformer requirements in the Washington State Energy Code, Commercial Provisions. Applicability Location in Building Department (yes,no,na) Code Section Component Compliance information required in permit documents Documents Notes Identify spaces eligible for lighting power exemption on plans C405.5.1.1 Total connected and in compliance forms; N/A Yea 0405.5.1.2 interior lighting power Identify lighting equipment eligible for exemption in fixture C405.5.1.3 N/A C405.5.1.4 schedule and in compliance forms; Indicate that exempt lighting equipment is in addition to general N/A area lighting and is controlled independently Yes 0405.4 Exit signs Provide exit sign types and rated watts per fixture in fixture E0.04 schedule (maximum 5 watts per fixture) C405.10 Cooler and freezer For lighting in walk-in coolers and freezers, and refrigerated KA C405.11 lighting warehouse coolers and freezers, provide rated lamp efficacy (in lumens per watt) in fixture schedule Lighting Power Calculation - Indicate compliance path taken Complete required compliance forms — proposed wattage per Yea 0405.5.2 Building Area Method building area does not exceed maximum allowed wattage per E0.04 building area. Identify locations of building areas on plans Complete required compliance forms — total proposed wattage NA C405.5.2 Space -By -Space does not exceed maximum allowed wattage. Identify locations Method of space types on plans, including retail display areas as applicable EXTERIOR LIGHTING POWER & EFFICACY Section C405.6 Provide fixture schedule with fixture types, lamps, ballasts, and rated watts per fixture; NA 0405.6.2 Total connected exterior lighting Identify exterior applications eligible for lighting power exemption on plans and in compliance forms; power Indicate that exempt exterior lighting is controlled independently from non-exempt exterior lighting KA Table C405.6.2(1) Exterior lighting zone Indicate building exterior lighting zone as defined by the AHJ Exterior building For building grounds fixtures rated at greater than 100 watts, NA C405.6.1 grounds lighting provide rated lamp efficacy (in lumens per watt) in fixture schedule Exterior lighting Complete required compliance form — proposed wattage for NA C405.6.2 power calculations exterior lighting plus base site allowed does not exceed maximum allowed MOTORS & TRANSFORMERS (Sections C405.8, C405.9) NA C405.8 Electric Motors For motors not part of an HVAC system, provide electric motor schedule on electrical plans with hp, rpm, and rated efficiency NA C405.9 Transformers Provide distribution transformer schedule on electrical plans with transformer size and efficiency It "no" is P" EMIT COORD COPY PLAN REVIEW/ROUTING SLIP PERMIT NUMBER: EL16-0223 DATE: 03/14/16 PROJECT NAME: INDIGO SOUTHCENTER SITE ADDRESS: 17275 SOUTHCENTER PKWY - SUITE 160 X Original Plan Submittal Revision # before Permit Issued Response to Correction Letter # Revision # after Permit Issued DEPARTMENTS: j V kv ?- '2,I14 Building Division Fire Prevention ❑ Planning Division ❑ Public Works ❑ Structural ❑ Permit Coordinator PRELIMINARY REVIEW: DATE: 03/15/16 Not Applicable ❑ Structural Review Required ❑ (no approval/review required) R:EVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: DUE DATE: 04/12/16 Approved ❑ Approved with Conditions ❑ Corrections Required ❑ Denied ❑ (corrections entered in Reviews) (ie: Zoning Issues) Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: 12/18/2013 SEA TAC ELECTRIC INC Home I,spaiiol Contact. Safety & Health 41*4 Washington State Department of ki Labor & Industries SEA TAC ELECTRIC INC Owner or tradesperson Principals HARGREAVES, TOM, PRESIDENT JORDAN, TOM, VICE PRESIDENT BEAN, ERIC, SECRETARY BEAN, ERIC, TREASURER HARGREAVES, TOM, AGENT HARGREAVES, KATHERINE, SECRETARY (End: 12/10/2008) BURKS, ROY, VICE PRESIDENT (End: 12/15/1995) Doing business as SEA TAC ELECTRIC INC Page 1 of 6 Search L&I>r�.y A-7lndex Help M} -- Claims } Claims & Insurance Workplace Rights Trades & Licensing 7056 S 220TH ST KENT, WA 98032 253-872-5553 KING County WA UBI No. Business type 601 510 212 Corporation Governing persons KATHERINE M HARGREAVES THOMAS R HARGREAVES; TOM JORDAN; License Verify the contractor's active registration / license / certification (depending on trade) and any past violations. Electrical Contractor Active. Meets current requirements. License specialties GENERAL License no. SEATAE1077RW Effective — expiration 12/16/1993-1211712017 Designated administrator. Jordan, Thomas License type Master Electrician Bond DEVELOPERS SURETY & INDEM CO Bond account no. 798649C Received by L&I 12/03/2008 Active. Meets current requirements. License no. JORDAT`914LR $4,000.00 Effective date 12/16/2008 Expiration date https:Hsecure.Ini.wa.gov/verify/Detail.aspx?UBI=601510212&LIC=SEATAEI077RW&SAW= 4/1/2016 ca E w C cu UI w J wl L C V O of rn c c m U O C cu E L a) co w, M. re M i M-ff on �i 1 z j , SYMBOL DESCRIPTION SYMBOL DESCRIPTION SYMBOL DESCRIPTION SYMBOL Hoc(D SURFACE LIGHT................... ......................... _........................................................... SWITCHBOARD MULTIO.U.TLET.AS.SEMBLY..(TYP_E..DENOTED)�1 ONE -LINE RISER DIAGRAM CONQ.UIT..G.ON.CEALED...1N..WALL...OR...OVERHEAD 0:1 F4-. F WALL -MOUNTED -FLOODLIGHT.............._......................... MULTI.O.U.TLET..ASSEMBLY _(TYPE..D.ENOTED) — CONDUIT _CONCEALED -BELOW ...FLOOR ........ � 110cd R RECESSED LIGHT .................................................................................................. FOA CLOCK .(TYPE .DENOTED) ...................... _............... _........ HEATER CONDUIT EXPOSED ..... --...... ......... .... ................................. ..... _............... D ° OOAA P.OLE..MOUNTED..LI.GHT.......................................................................... p POWER -POLE ._(OPEN ...OFFICE ._ ST YLE)...._..... _SR— SURFACE_RAC.EWAY.._..._ .... ........ _.......___...... _....... �110od f f f f B1311 NFDS NON-FUSED SAFETY SURGERY.SERVI.CE-COLUMN... _.... _........ ....... _................ —0 CONDUIT ..TRANSITION ..UP ... _ ....................................... ............... ..... IE]-- DIA POLE MOUNTED FLOODLIGHT © STATIC.GROUND..RECEPTACLE (TYPE'DENOTED) o CONDUIT -TRANSITION DOWN- F »acd 0G SURFACE.LINEAB_LIGHT . ................_._. @LIGHTNING.P_ROIECTION.AIR..IEBMINAL DISC �y CONQUIT_S.TUBBED.OUT. 110cd P2 SUSPENDED...OR.PENDANT. LIGHT ............ ....... .... o LI GHTNING..PROTECTION.CONDUCTOR SPLICE ADO I LOW_V.OLTAGE..P.OWER WIRING ........ ..... ..... .__...._. F tlocd OH RECESSED.. LINEAR LIGHT ............ ..... ... ..... ... ......... ® GROUND._ROD..(PLAN..VIEW)...................... ........ ....... ,_ Ex -, EXISTING..CONDUIT ................. _...._ ................. o AF AMP FRAME DN DOWN FA ANNUN T� { STRIP.LIGHT............. ......... .......... .... TAMPER RESISTANT GROUND..CONNECTION TO_STEEL._OR._STRUCTURE,_-uE_, UNDERGROUND'ELEC.TRICAL_ .................... F4 ©p T1p T1pTR1 TRACK ANDTRACK.LIGHT........ ....... ........... o GROUND CONNECTION--. WELD ,–UHVE_� UNDERGROUND...HIGH...VOLTAGE.ELECTRICAL R/RVF135R®5 0®O ����_� EM EMERGENCY.. BATTERY LIGHT _._ _.........._... -0- UTILITY._ SERVICE., POWER..P.OLE..(SITE)._ IG UNDERGROUND..TELEPHONE.... .............._......... Q_ FOE (@E EX1T..SIGN _..... ........ ... . .......... _..... .... ... ...... ..... _... ® SPECIAL.RECEP.T..OR_CONN.._(SEE..SCHEDULE) --ucoM_- UNDERGROUND ..COMMUNICATIONS .......... ... .._ Q— H" ,•N=; LIGHT -FIXTURE -ON (EM) LIFE.SAFETY_BRANCH o SPECIAL CONNECTION _(SEESCHEDULE) __UTV _ UNDERGROUND..CABLE_TELEVISION........... ..... A Fa LIGHT.FIXTURE.ON_(EM) CRITICAL BRANCH IU p JUNCTION.BOX .... ......... ... .... .. .... ......... ........... ,-uFIBR_ UNDERGROUND..FIBER OPTIC--- .............. ....... FO O TV TELEVISION AHU AIR HANDLING UNIT UV/IR UV/IR {® LIGHT. FIXTURE_ON.EMERGENCY .CIRCUIT © PULL.BOX................ ..... .......... .................. -11.1 ...... .._ —OHE— OVERHEAD..ELECTRIC... .. ...... .._ iO 0 F LIGHT. FIXTURE WITH. EMERGENCY. BALLAST INV CIRCUIT. BREAKER. PANEL....... ......... —oHr— OVERHEAD_TELEPHONE ....._ __ ....._ CO CO Ftp a LIGHT_ON_CORD.REEL (TYPE DENOTED) ® POWER.OR.DISTRIBUTION PANEL ELECTRIC, ELECTRICAL BRANCH, _CIRCUIT..HOMERUN _.. ❑z oLIGHTING CHANNEL.WIRE (TYPE DENOTED) o SPECIALL CABINET. (TYPE_ DENOTED).......... �� FLEXIBLE_CONDUIT_OR.FIXTURE..WHIP...... Q ELEVATOR SINGLE POLE _SW.... ... ... .. .... .... ._ ... .................TRANSFORMER JUNCTION BOX (TYPE.DENOTED). ......... PULL BOX OR PUSHBUTTON UNDERFLOOR..RACEWAY. SYSTEM ............. ......... IQI 1642 2. PO LE.S I N GLE TH ROW SW:__ _._..... .... ._ I )SF -1 ��®ll MOTOR.(SEE.SCHEDULE)...... ............... .... : ......... ® CABLE _TRAY.. ..... ....... ............ .................. ... ...... . ... . ......... ..... .. ... PE lbq3 3-WAY.SW. _ ..... ._.......... UNDER COUNTER MAG. MOTOR STARTER OR..CONTACTOR E 3 CONDUIT. SLEEVE ............... ................... _ ENERGY MANAGEMENT SYSTEM Ib0:4 4-WAY.SW.....__. __ PED COMB. MOTOR._STARTER_(NON-FUSED) 14 TELEPHONE. OUTLET ........ .... ......... ....._ APPROX f K KEYED SW. _.... _.... _._ ELECTRICAL METALLIC.TUBING COMB.. MOTOR.STARTER.(FUSED)_ ......._ 14 W WALL _TELEPHONE _OUTLET ... ... .... ... ........ .... .... .... ._._. POWER FACTOR ° DIMMER SWITCH ......_ AQ -STAT SAFET.Y.DISC...SW..(NON-FUSED).L 111NFORMATION_QUTLET_ ELECTRIC PNEUMATIC KVAR O [69.s OCCUPANCY.SENSOR SWITCH. Il SAFETY DISC. SW.. (FUSED) ._.... Ic INTERCOM...OUTLET_LOCATION............ ... ........ _. ARCHITECT, ARCHITECTURAL M 169 C MOMENTARY.CONTACT-SWITCH........... _. i BUS..DUCT_WITH.PLUG UN..DISCONNECT (FUSED) FIN TELEVISION_OU.TLET._........ ........... T g 1.69T TIMER SWITCH .......... ... .......... .... ........ .VARIABLE. AMP SWITCH FREQUENCY. DRIVE_ ........................ ELECTRIC WATER COOLER MULTIP..LE_SERVICE._OUTLET...._ _ . —� ELR STDTIME..DELAY..S.W.IT.CH .....................................................................................® UTIL RELAY ..................................................... -.............. ..... _.................... ............................................. ...... ® ;O.0TLET..IN..FLO.OR._...(MICROP.H.ONE...SHOWN) EXIST SSP PAN ...SPEEQ...CONTROL......... _............. _.................................................. © ENCLOSED ._C1RCUIT..BREAKER........ __..- .......... _.... _..... � i MULTIP.LE..SERVI.CE...FLR...O.U.TLET.._................ _.... _._.. p 16_�-M MOTOR..HP...RATED...SWITC.H......................................... _.......... PS$ PRESSURE ._SWITCH ...... ....... _.............................. __._......... _........ _.............. ® WIRELES_S..ACCESS...POINT ....................................... _._................ _ 1-0 I -p P.USH.B.UTTON........................... ................. ....... ...... ... ..................................................... Fs FLOAT ...SWITCH .......... ---..... __.........................................__._.... - ............................ _ AUTOMATIC SELL........ ................. _...................... ............ _.... _._._... _.._.............................................. _............. _............ _ EXPLOSION PROOF LT SINGLE.REC.EPT...................... ......................... ...................................................... QIR OCCUPANCY ...SENSOR..-...TYPE..DEN.OTED Fp/ !BUZZER ............... _.......... -................................. ................................... .............................. _.._............. F0 AUXILIARY ,D_UPLEX.RECEP.T.............. .._............. .__................................................................. Ls A LI.GHT..LEVEL...SEN.S.OR..,._TYPE._D.ENO.T.ED F� CHIME.-.._...._....._...._._.........._.._........_....................._..._......................................................._.............. FD V S.WIT.CHED...DUPLEX..RECEPT_.............................................. 1® PHOTOCELL ..... __._......................................... ....... .... ... _....................................... _....... CD DOO.R..SIGNAL...-..AP?....UNIT............. _....... ............. ... __...... I® -•R LIGHTNING PRV POWER ROOF VENTILATOR VA VOLT-AMPERES AWG AMERICAN WIRE GAUGE FABP D.EDICATED...D.UPLEX..RECEP.T........... ............................ 1© TIME ...CONTROL-SWIT..CH..(TIME..SWITCH) PT SPEAKER. ..(WALL_OR..CEILING ..MT.)... -....-..-..._. +* VIDEO DISPLAY TERMINAL ....................................................... NUMIQISTAL..._................ _._ ....._........___................................. . �s : MORN.TYPE.SPEAKER �ABOVE.COLINTERRECEPT. PVC GFI..REC.EPT.................... .......................................................... ..... ...................................... (D THERMOSTAT ........... .... ............. _._......... ........... _._............... _......................_........ . V.9y VOLUME..CONTROL................... _._.._.... _...... _........... ._............................. _.._.. +® a ABOVE..C.O..UNTER..GFI..RECEPT............. ......_. o H1 BASEBOARD-HEATER.(TYP.E..DENOIED) (CONDUIT) MICROP.HONE..OUTLET..._ ............................... +Q BD FO.URPLEX.RECEP...T.................................................. ..................................... H WALL -HEATER ..(TYPE-D.ENOTED.)... .... _...... _.........1-0 MAG.S PROJECTOR .- CONTROL OUTLET ..................... 1 +® POWER DEDICATED ...F...O.URPLEX.RECEPT.................. [GD1 HAND ...OR_HAIR.DRY..ER.(.TYP.E..DENOTED) .� ;ANTENNA .... ...................... .......... _.... _... ......... .... .................................... ......... _.... _............... +02 MIC 24.0... VOLT ...BECEPL....................................... .._............. ...... .............................. SOLENOID ..VALVE ._.... _......_..... __.... ......... _.............. ...... ........ _................... WEATHERHEAD_....._.............._.__................---........................................................... N N [02 S2 BUILDING MANAGEMENT F.LUSH..F..LOOR_RECEPT...(D.UPLEX-SHOWN)SXMBQL...LNDIGAT.ES...E)SISTING FLOOR MC O KEYED.NOTE. .(SEE._SCHED.ULE)................................. -.... NCM ®FLUSH ...CEILIN.G..MO.UNT..RECEPT.._......................... HATCHED ._SYMBOL ...INDICATES ...REMOVED FLUOR ..................... _._... ...... ........... ....... _.... ......__............. _.... _........ _..... _................... __... __.............. ................... ..... NCC MAIN CIRCUIT BREAKER ?ECEPT..ON..DROP...CORD..(DUPLEX..S.HOWN).............................................. ..................... ................. _._...................... _...... _._.................. ............ _........... _ WITH I... _...... ........ _._... _-........ _............... _....... _.._... _.... _.................. ................................................... ........_.................... . NC�ANNUN p. RECEPT..ON....CORD...REEL..(D.UPLEX..S.HOWN) MCC _....... _ . RCPT ...... ....... .---......... ................. .... ... _........................ ................ .... . _ ED WIRE GUARD E UIP.MENT..P.L..U.G.................................. _...... _......................................... ............ CONDUIT _.__._.................................................. FUSED SAFETY DISCONNECT MDC r ALL DISTANCES ARE TO CENTER OF DEVICE OR EQUIPMENT UNLESS OTHERWISE NOTED. DEVICES INDICATED AT 48" MAY NOT BE INSTALLED WITH ANY OPERABLE PART HIGHER THAN 48". DEVICES MAYBE INSTALLED IN CONCRETE MASONRY UNITS WITH THE TOP OF THE DEVICE AT 48". DISTANCE ABOVE TOP OF DOOR FRAME " DISTANCE TO TOP OF EQUIPMENT OR DEVICE "' DISTANCE TO HIGHEST OPERABLE PART OF EQUIPMENT " ' DISTANCE BELOW CEILING WATER HEATER 1P 1 POLE (2P, 3P, 4P, ETC.) DCP DOMESTIC WATER HT HEIGHT NEMA NATIONAL ELECTRICAL SWBD SWITCHBOARD E5.01 ONE -LINE RISER DIAGRAM E5.02 CIRCULATING PUMP HTG HEATING MANUFACTURER'S SYM SYMMETRICAL A AMPERE DEPT DEPARTMENT HTR HEATER ASSOCIATION SYS SYSTEM AC ABOVE COUNTER OR AIR DET DETAIL HV HIGH VOLTAGE NFDS NON-FUSED SAFETY TEL TELEPHONE 0 cu cq CONDITIONER DIA DIAMETER HVAC HEATING, VENTILATING AND DISCONNECT SWITCH TEUDATA TELEPHONEIDATA ACLG ABOVE CEILING DISC DISCONNECT N 2 0 AIR CONDITIONING NIC NOT IN CONTRACT TERM TERMINAL ADO AUTOMATIC DOOR OPENER DIST DISTRIBUTION HWP HYDRONIC WATER PUMP NL NIGHT LIGHT TL TWIST LOCK AF AMP FRAME DN DOWN N.O. NORMALLY OPEN TR TAMPER RESISTANT AFF ABOVE FINISHED FLOOR DPR DAMPER IC INTERRUPTING CAPACITY NPF NORMAL POWER FACTOR T -STAT THERMOSTAT AFG ABOVE FINISHED GRADE DS SAFETY DISCONNECT SWITCH IG ISOLATED GROUND NTS NOT TO SCALE TTC TELEPHONE TERMINAL AFI ARC FAULT CIRCUIT DT DOUBLE THROW IMC INTERMEDIATE METAL CONDUIT CABINET INTERRUPTER DWG DRAWING INCAND INCANDESCENT OH OVERHEAD TV TELEVISION AHU AIR HANDLING UNIT IR INFRARED OL OVERLOADS TVTC TELEVISION TERMINAL AL ALUMINUM EC ELECTRICAL CONTRACTOR INV INTERLOCKWITH CABINET ALT ALTERNATE ELEC ELECTRIC, ELECTRICAL PA PUBLIC ADDRESS TYP TYPICAL AMP AMPERE ELEV ELEVATOR J -BOX JUNCTION BOX PB PULL BOX OR PUSHBUTTON AMPL AMPLIFIER EM EMERGENCY PE PNEUMATIC ELECTRIC UC UNDER COUNTER ANNUN ANNUNCIATOR EMS ENERGY MANAGEMENT SYSTEM KV KILOVOLT PED PEDESTAL UE UNDERGROUND ELECTRICAL APPROX APPROXIMATELY EMT ELECTRICAL METALLIC.TUBING KVA KILOVOLT -AMPERE PF POWER FACTOR UG UNDERGROUND AQ -STAT AQUASTAT EP ELECTRIC PNEUMATIC KVAR KILOVOLT -AMPERE REACTIVE PH PHASE UH UNIT HEATER ARCH ARCHITECT, ARCHITECTURAL EQUIP EQUIPMENT KW KILOWATT PIV POST INDICATING VALVE UT UNDERGROUND TELEPHONE AS AMP SWITCH EWC ELECTRIC WATER COOLER KWH KILOWATT HOUR PNL PANEL UTIL UTILITY AT AMP TRIP EXIST EXISTING PP POWER POLE UV UNIT VENTILATOR OR ATS AUTOMATIC TRANSFER SWITCH EXH EXHAUST LOC LOCATE OR LOCATION PR PAIR ULTRAVIOLET AUTO AUTOMATIC EXP EXPLOSION PROOF LT LIGHT PRI PRIMARY AUX AUXILIARY LTG LIGHTING PROJ PROJECTION V VOLT AV AUDIO VISUAL FA FIRE ALARM LTNG LIGHTNING PRV POWER ROOF VENTILATOR VA VOLT-AMPERES AWG AMERICAN WIRE GAUGE FABP FIRE ALARM BOOSTER POWER LV LOW VOLTAGE PT POTENTIAL TRANSFORMER VDT VIDEO DISPLAY TERMINAL SUPPLY PANEL PVC POLYVINYL CHLORIDE VERT VERTICAL BATT BATTERY FACP FIRE ALARM CONTROL PANEL MAX MAXIMUM (CONDUIT) VFD VARIABLE FREQUENCY DRIVE BD BOARD FCU FAN COIL UNIT MAG.S MAGNETIC STARTER PWR POWER VOL VOLUME BLDG BUILDING FIXT FIXTURE MIC MOMENTARY CONTACT BMS BUILDING MANAGEMENT FLR FLOOR MC MECHANICAL CONTRACTOR QUAN QUANTITY W WATT SYSTEM. FLUOR FLUORESCENT MCB MAIN CIRCUIT BREAKER W/ WITH FU FUSE MCC MOTOR CONTROL CENTER RCPT RECEPTACLE WG WIRE GUARD C CONDUIT FUDS FUSED SAFETY DISCONNECT MDC MAIN DISTRIBUTION CENTER REQD REQUIRED WH WATER HEATER CAB CABINET SWITCH MDP MAIN DISTRIBUTION PANEL RM ROOM W/O WITHOUT CAT CATALOG MFR MANUFACTURER RSC RIGID STEEL CONDUIT WP WEATHERPROOF CAN CABLE TELEVISION GA GAUGE MFS MAIN FUSED DISCONNECT RTU ROOF TOP UNIT CB CIRCUIT BREAKER GAL GALLON SWITCH XFMR TRANSFORMER CCN CLOSED CIRCUIT TELEVISION GALV GALVANIZED MH MANHOLE SC SURFACE CONDUIT XFR TRANSFER CKT CIRCUIT GC GENERAL CONTRACTOR MIC MICROPHONE SEC SECONDARY CLG CEILING GEN GENERATOR MIN MINIMUM SHT SHEET COMB COMBINATION GFI GROUND FAULT CIRCUIT MISC MISCELLANEOUS SIM SIMILAR CMPR COMPRESSOR INTERRUPTER MLO MAIN LUGS ONLY S/N SOLID NEUTRAL CONN CONNECTION GFP GROUND FAULT PROTECTOR MMS MANUAL MOTOR STARTER SPEC SPECIFICATION CONST CONSTRUCTION GND GROUND MOA MULTIOUTLET ASSEMBLY SPKR SPEAKER L CONT CONTINUATION OR GRS GALVANIZED RIGID STEEL MSP MOTOR STARTER PANELBOARD SP SPARE ANGLE CONTINUOUS (CONDUIT) MSBD MAIN SWITCHBOARD SR SURFACE RACEWAY @ AT CONTR CONTRACTOR GYP BD GYPSUM BOARD MT MOUNT SS STAINLESS STEEL 0 DELTA CONV CONVECTOR MT.0 EMPTY CONDUIT SSW SELECTOR SWITCH FEET CP CIRCULATING PUMP HOA HANDS -OFF -AUTOMATIC MTS MANUAL TRANSFER SWITCH S/S STOP/START PUSHBUTTONS INCHES CRT CATHODE-RAY TUBE SWITCH MTR MOTOR, MOTORIZED STA STATION # NUMBER CT CURRENTTRANSFORMER HORIZ HORIZONTAL STD STANDARD 0 PHASE CTR CENTER HP HORSEPOWER N.C. NORMALLY CLOSED SURF SURFACE MOUNTED (11 CENTER LINE CU COPPER HPF HIGH POWER FACTOR NEC NATIONAL ELECTRICAL CODE SW SWITCH P- PLATE RE.ALARM.CHIME.W/STROBE._(CANDELAS) _ ..... RE.ALARM STROBE (CANDELAS) ..... ..... ... ..... .... ..... RE.ALARM. SPEAKER W/STROBE (CANDELAS)... RE ALARM. REMOTEANNUNCIATOR_.._. _..... (TYPE._&.' '.SMOKE. DETECTOR (TYPE.DENOTED) ..... )TE.TEST/STATUS..STATION . __. ......... r. — DISTANCE TO BOTTOM OF DEVICE NOTE REGARDING DRAWINGS: THESE DRAWINGS ARE PROVIDED FOR YOUR USE RELATING EXCLUSIVELY TO THE PROJECT CONTAINED HEREIN. SEA -TAC ELECTRIC, INC. PROVIDES THESE DRAWINGS WITH THE FOLLOWING STIPULATIONS: 1. THIS DOCUMENT, AND THE IDEAS AND DESIGNS INCORPORATED HEREIN, AS AN INSTRUMENT OF PROFESSIONAL SERVICE, IS THE PROPERTY OF SEA -TAC ELECTRIC INC. AND IS NOT TO BEED N US , I WHOLE OR IN PART, FOR ANY OTHER PROJECT WITHOUT THE WRITTEN CONSENT OF SEA -TAC ELECTRIC, INC. THE DESIGNS CONTAINED HEREIN ARE PROTECTED BY THE RULES AND REGULATIONS OF U.S. COPYRIGHT LAWS. 2. THESE DRAWINGS AND DOCUMENTS WERE COPIED FROM COMPUTER DATA CREATED AS A STEP IN THE PRODUCTION OF PHYSICAL DATA FOR THIS PROJECT. THERE MAY BE DISCREPANCIES BETWEEN THESE DOCUMENTS AND THE COMPUTER DATA. WHERE SUCH DISCREPANCIES EXIST, ONLY THE PHYSIAL DOCUMENTS AND DRAWINGS CAN BE RELIED ON TO REFLECT THE WORK OF SEA -TAC ELECTRIC, INC., WHO MAKES NO GUARANTEES OR WARRANTIES REGARDING THESE DOCUMENTS OR THE DATA THEREIN. 3. IN ACCEPTING THESE DOCUMENTS, YOU ASSUME ALL LIABILITY FOR THE ACCUARCY, UTILITY, OR SUITABILITY FOR ANY PRUPOSE FOR ANY DATA THESE DRAWINGS CONTAIN. COPYRIGHT 2016 I- 1,0:01:4 c7 -1q I,101t*` NOTE:"CONTRACTOR" MEANS "ELECTRICAL CONTRACTOR" WHEN REFERENCED ANYWHERE IN THE ELECTRICAL CONSTRUCTION DOCUMENTS UNLESS WORK AND EQUIPMENT HAS BEEN COORDINATED BETWEEN THE ELECTRICAL AND GENERAL CONTRACTORS TO BE PROVIDED BY THE GENERAL CONTRACTOR. "NEEDED", "PROVIIDE", AND "INSTALL" MEANS ALL ITEMS CALLED OUT IN THE CONTRACT DOCUMENTS AND ANY ADDITIONAL ITEMS NOT CALLED OUT BUT REQUIRED TO MAKE A COMPLETE AND OPERATIONAL SYSTEM. SCOPE: THE INTENT OF THE DRAWINGS IS TO PROVIDE A COMPLETE AND FULLY OPERATIONAL ELECTRICAL SYSTEM. THE ELECTRICAL CONTRACTOR SHALL FURNISH AND INSTALL ALL LABOR, MATERIAL AND EQUIPMENT NECESSARY TO COMPLETE THE ELECTRICAL WORK. PERMITS AND FEES: THE ELECTRICAL CONTRACTOR SHALL PROCURE AND PAY FOR ALL PERMITS, FEES AND INSPECTIONS NECESSARY TO COMPLETE THE ELECTRICAL SCOPE OF WORK PRIOR TO STARTING THE WORK. WARRANTY: THE ELECTRICAL CONTRACTOR SHALL UNCONDITIONALLY WARRANTY ALL WORK TO BE FREE OF DEFECTS IN MATERIAL AND WORKMANSHIP FOR A PERIOD OF ONE (1) YEAR FROM THE DATE OF FINAL ACCEPTANCE BY THE OWNER OR OWNER'S REPRESENTATIVE AND WILL REPAIR OR REPLACE ANY DEFECTIVE WORK PROMPTLY AND WITHOUT CHARGE AND RESTORE ANY OTHER EXISTING WORK DAMAGED IN THE COURSE OF REPAIRING DEFECTIVE MATERIALS AND WORKMANSHIP. CODES: PERFORM ALL WORK IN ACCORDANCE WITH THE CURRIE AIONAL ELECTRICAL CODE, STATES, CITY ELECTRICAL CODES, AND ALL OTHER APPLICABLE CODES INCLUDING ANY STATE OR LOCAL ENERGY CODES. ALL WORK SHALL ALSO BE IN COMPLIANCE WITH BUILDING OWNER'S CRITERIA. IN CASE OF CONFLICT BETWEEN THE DRAWINGS, SPECIFICATIONS, CODES, ORDINANCES, AND AUTHORITIES HAVING JURISDICTION, THE MOST STRINGENT STANDARD (IN THE OPINION OF THE ENGINEER) SHALL APPLY. STANDARDS: EQUIPMENT AND MATERIALS SHALL CONFORM WITH APPROPRIATE PROVISIONS OF NEC, WAC, ASTM, UL, ETL, NEMA, ANSI, AND OTHER APPLICABLE AGENCY AS THEY APPLY TO EACH INDIVIDUAL UNIT OR ASSEMBLY. COPYRIGHT 2016 d pfor It No. Plan f��)irr ��;r,R } ► SIaE)j?i.°i to ®rrBrs 6Q..nd U 't di the viol'r. ic.'i j "1 I'V q ac:UP Y3, F � �• �C�,_'a'; Of GPPr vo [41 Field Cowrj and iJOJ r 1 q Ey: Date: City o14 Awiy'� BUILDING DIVISION No changes shnl! ho made to the scilla of work tgvithc ut prior emprovai of Trj't,,,Aa building Division. t!O3]': t ^ .;_;Cis will require a new plan submittal -nJ may i�n:.'udo additional p!an reviaw fees. RECEIVED CITY CE TUKWILA MAR 14 2016 PERMIT CEN�pTER_ REVIEWE® FD COMPLIANCE Wi' NFPA 70 - NPC DRAWING INDEX # SHEET NAME MAR 2 5 ZU16 DIVIS EO.01 SYMBOLS AND ABBREVIATIONS E0.02 ELECTRICAL SCHEDULES E2.01 POWER PLAN E3.01 LIGHTING PLAN E4.01 ROOF MECHANICAL POWER E5.01 ONE -LINE RISER DIAGRAM E5.02 PANEL SCHEDULES w 1) _O F- cn z O U oft W 00 LLJ CL co LLJ Uj Lu CD ca Lo . ,iia➢V11T !-6i'DFOR. ❑ El�c�sai ffr;uxbing PipIng 0.11) of Ta No. IDescription Date SYMBOLS AND ABBREVIATIONS PROJECT NUMBER 16036 DATE 03/11/2016 DRAWN BY IE CHECKED BY CM SCALE 1211 _ 1 1_011 a v cc UI '�ZZ a-, M Il1�_} to N N ti co N ti co M N M N v z z 0 z_ _ a E I.L. 8 W 0 cu cq W w 0) LLj W N M N 2 0 O rn 3: Lo Lo z Y oft W 00 LLJ CL co LLJ Uj Lu CD ca Lo . ,iia➢V11T !-6i'DFOR. ❑ El�c�sai ffr;uxbing PipIng 0.11) of Ta No. IDescription Date SYMBOLS AND ABBREVIATIONS PROJECT NUMBER 16036 DATE 03/11/2016 DRAWN BY IE CHECKED BY CM SCALE 1211 _ 1 1_011 a v cc UI '�ZZ a-, R ca w C CU U w J w J 2 (D 0 O v7 O' m E U O N C (U U) L_ O U) D A MECHANICAL EQUIPMENT CONNECTION SCHEDULE ELECTRICAL DATA DISCONNECT 120 TYPE MARK AREA SERVED QTY VOLT PH INDIVIDUAL EQUIPMENT INFORMATION MANUFACTURER UNIT INFO TYPE FRAME/FUSE SUPPLIED BY IELECT NOTES F1 9 MCA MOCP F/NF NEMA SIZE AMP ELECTRICIAN MECHANICAL KVA FLA HP FLA (HP) TOTAL KVA EF -1 TOILETS 1 120 1 0.252 LIGHTING FIXTURE SCHEDULE 1/10 COUNT MANUFACTURER 2.1 VOLT NF BALLAST DESCRIPTION FLAG APPARENT LOAD NOTES F1 9 Cooper Lighting 1 EF -2 TOILETS 1 120 1 0.252 Cooper Lighting 1/10 120 V LED 2.1 35 VA 23DR Straight & Narrow - Individual & Continuous NF 1 TBD TBD 120 V LED 1 RTU -1(E) TOILETS 1 208 3 5.872 LED LED DRIVER 30 VA TBD 5.872 16.3 TBD F 3R 30 25 X F5 2 RTU -2(E) TOILETS 1 208 3 5.872 F6 41 Cooper Lighting 5.872 16.3 LED F 3R 30 25 X Series 23DR 2 1. FOR 120V FANS ELECTRICAL CONTRACTOR TO PROVIDE MOTOR RATED SWITCH FOR LOCAL DISCONNECT WHERE REQUIRED. 2. PROVIDE HACR RATED BREAKER AT PANEL OR LOCAL FUSED DISCONNECT AT UNIT IN LIEU OF NON-FUSED. REVIEWE®.F® COMPLIANCE W NFPA 70 - NE( MAR 2 5 2016 ch L j LO N .`-- LIGHTING FIXTURE SCHEDULE TYPE COUNT MANUFACTURER SERIES NO. VOLT LAMP BALLAST DESCRIPTION FLAG APPARENT LOAD NOTES F1 9 Cooper Lighting Series 23DR 120 V LED LED DRIVER 35 VA 23DR Straight & Narrow - Individual & Continuous FIX 7 Cooper Lighting Series 23DR 120 V LED LED DRIVER 35 VA 23DR Straight & Narrow - Individual & Continuous F2 1 TBD TBD 120 V LED LED DRIVER 79 VA TBD F3 4 TBD TBD 120 V LED LED DRIVER 30 VA TBD F4 2 TBD TBD 120 V LED LED DRIVER 19 VA TBD F5 6 TBD TBD 120 V LED LED DRIVER 16 VA TBD F6 41 Cooper Lighting 22EN and 24EN 120 V LED LED DRIVER 35 VA Encounter - Troffer LED Module F7 5 Cooper Lighting Series 23DR 120 V LED LED DRIVER 70 VA 23DR Straight & Narrow - Individual & Continuous F7X 4 Cooper Lighting Series 23DR 120 V LED LED DRIVER 70 VA 23DR Straight & Narrow - Individual & Continuous F8X 1 Cooper Lighting 22EN and 24EN 120 V LED LED DRIVER 35 VA Encounter - Troffer LED Module F9 9 TBD TBD LED 18VA TBD F9X 3 TBD TBD 120 V LED LED DRIVER 18 VA TBD X1 2 TBD TBD 120 V LED LED DRIVER 5 VA ABL Recessed 2x4 REVIEWE®.F® COMPLIANCE W NFPA 70 - NE( MAR 2 5 2016 No. I Description I Date ELECTRICAL SCHEDULES I BUIL®IAIG ®I�lISI� , RECEIVED CITY of TUKWILA MAR 14 2016 PROJECT NUMBER 16036 r: ch L j LO N .`-- N ti co N ti 00 M N M N UW Z ,L a E U 0 U t , W N co V Uj J W 3: N M N _ I— O CC) 0) O U Lo m Z Y I No. I Description I Date ELECTRICAL SCHEDULES I BUIL®IAIG ®I�lISI� , RECEIVED CITY of TUKWILA MAR 14 2016 PROJECT NUMBER 16036 r: �io c E -a W c co U� W J W LI V '0 vJ IS c+co E V 0 0 ca L 0 ^cn J A s Vn c w C cc .I U w J W� L U O U)1 0 tm 'O c co C N V O a c CD D A] + 32 6 35 6 31.2 �+23 4' F F64 5. 2 +45. 7 +. +. 1.6 38 9 43.24 �7 8 28 6: +38.3 4 39 0 9-'•••32 • ....-_-....._..... ..... ............. 46. F6 [U. - + 6 16 35, 0 89 42 SF, 3 1 135 49. 49. + +6 7 0.0 + 1. + 39,.0 53.0 4 .0 + 1a+66 F 66 ; fA 57.4 48.0 309 2 39 5 42 ' . 35 + _:... + ._... +64.;0 + 67.7 .6.9_1 + + +' +' + ' .39':3 36'. 6..• ' '3:6.. 9 3' .'5 39.0 32 _..... _..._._._.............._...._ ----� MN Lf) Lo LO + + + 4' F F64 5. 2 +45. 7 +. +. 1.6 2. 6 32.3 .39.0 36.0 6: 4b 7.4 55.0 4'6'.4 .3.7:.'6 ' 2 E 56. 56. 46. F6 [U. - + 6 16 b_,._.__,:..:_._. + 54 9 14 _..__..... ......... _...:..__.,.__. __.. 4 . 49. 49. + +6 7 0.0 + 1. + 39,.0 53.0 4 .0 + 1a+66 F 66 ; 65.5 57.4 48.0 3 . 2 48. 2 48. 2 39. + 66. ' . L + ab + +64.;0 + 67.7 .6.9_1 + ILED ATEa _ 54. _4a SUITE r 3. 4a _- + 99 50.9 1* ��.8 .8 48.7 45.4 51.0 1106'3.�F 64.7 67.1 62 _ _ 54.7- 4 . + -._- +67.5 69.6 64.7 + 5.6 59.8 +65.7 + 56. + + 46.5 5 .3W7 51.4 4 51. + 7 9 . 0 0. 59. 51- 39 8 71.2 62. r a_ F6 I 4a b43. 6a 51. '6 40. �36 38.7 '52. 47.2 !N 0+ 8.6 b 40.7 48.6 45.3 47.0- 0 '--- FSU .6 0 4 62.7 X61 + 4-.3-�51..4 4a•-110_S_F---- - 6 +62.9 - _-_ - + 8.7 9.3 38 .4 4 ,1 .42 . 41.5 53.6 55.9 50.4 42.4 3 + + i 33.4 39.!6 --___ +' +' + ' .39':3 36'. 6..• ' '3:6.. 9 3' .'5 39.0 32 _..... _..._._._.............._...._ ----� MN Lf) Lo LO �T 43. 51.I 4' 9. F64 5. 2 +45. 7 A F 50. I + v .1a 7 -=' - ._.:..i....__:.......- --._ / _..:..._. -- - F6 LL 4b �.._. 8. 58.I +55. "� E 56. 56. 46. F6 [U. - + 6 16 SF + 54 9 14 _..__..... 57 . 4. 4 . 49. 49. + +6 7 5. 56. 45. + +�.9 - 4 4a 1a+66 F 4a ; 4 1 + 67.0 47.7 43. 2 48. 2 48. 2 39. + 66. ' . L + ab 3:::;.: 3 .:. :: -:_: - --- - -- 8.6 8.3 31.3 37.0 36. 6 - �� 8 F1 + F1X + + + + �_._ - �- y - + + + + + + + 6 16.4 - 19.0 19.0 22. 23.5 35 Fs`e.1 35.3 3 35.2 38 35.0 2� 1 1 ._.-•19- 2 2 E11�L _.�___._ EM_ 2 __ '_ - -' PANEh X-RAY __ ___ 0.4 15.7 21.1 21.8 18.6 17.1 19.5 24 . 2 25.0 _22 2-• 8~- 30.2 39...7_..,.44 .:4 :-:42 7.:' 3.9:7 4.1:. 9' .4.4 :'7 4.0 , 3'' 3 i z _ 7 1 .7 2. 27. 18.5 20 1 •: 2:8..4: � 3 : -, .: 43:1 . � •. 40.`6 30:. } 25.2 29.5 30. 0.9 3 3---_-,_�_-9 � . 1 ir.--.-.__.........._ ......................._.:, - , . . + + + + + + + + +:. 35.2 91 . 6,� 41.3 39.9 37.9 6. 0 31 . 5:'S ; 19..;, 0 0..1. 16 26; 8 '.' 35.6 , .42:4' .43..5 -'.• 4.2':1, -..43_, 0:'';42: ` 37'. ' •28.:3. 22 1b y CAR' is : 42. 0. 4 45.9 28 4 32.0 28. 8.. 7.'. 4.5 5..1" 19 24'..1 3�X. '39:. 40..7TM1.'4 :.`'..8 39.1• •,'3:3..1 :.23.:8.: ,15...4' �0, 1a :: F X 45. 54.2 53.1 47.8 42. A 1 2 ,: 2:3..9 19 20:. 8; ; 2 .: 34'.1 35.7 9 9 33:5 ..:.2 8.. A` . ' 20.3 .: 13.:5• . "9: 4, FILET .. • . _ .:...:...........__ :....: - _::-_::----::.-- : _.. ............._.-.........._.....:- - - L..: 2, 47 SF - '... + +F + +F +48. + + . + T. -+'..',. + + 4$ + + Ji, i + + , + I os+ + 45.3 . 3 56.1 I4 0 34. 14:'2 17:. •9': 18:2 23.3 36.4 3 28 2 27.7 28.9 23. ----- 217 SF 42. 51.2 54.5 53.8 50.4 44.6 35.0 -:22.::9 41.8 4 .0 4 3 1 2 T 2 13 2 .3 .8 +3 33.4 26 �f7C� -....._.:._............. F6 I T8+ + + + + F + + + + + + + + + + + �+ + PoCT+ 38.6 0 50.7 .9 48.3 .0 33.7 122.7 2 .0 3 .6 4 .1 4' 3 4 ,,,0 2 29 7 2 .7 2 - 28.3 29.3 II WOR E ...:.:.::::::a::.`:: SF . _ - �. - - -' -- - + + + + + + + I L441+ ++ A g j 6 21 )-2 .2 3 .2 4 -3 391+++.0 3 .0 30.0 2 +3 1 .6 20. 21.4 PANEL X-RAY MAIN BREAKER I CLC/IJMIM L -MA I I IIVV BACKBOARD CONTROLPANEL 1ST FLOOR LIGHTING PLAN PANEL L1 (SEC 1+2 (LCP) 1/4" = 1'-0" Piss:] 9 �.1 21.2 1 .5 20.2 2 5.2 21.2 18.2 19.1 2 El Um ,�,r....i•Hy�1_---• MN Lf) Lo LO �T -- 5 4' 57.0 53.Q.' •43':3: '. -3 OF 54. 7':.6 37.9:.. 29 i.._ x v .1a 7 -=' - ._.:..i....__:.......- --._ / _..:..._. -- - F6 LL 113 SF + 1 6 + . 0 7 .2 6 5-� F6 [U. + 57.2 + 6 .1 + 65.1 + 54 9 14 +F� 58. CD CD 4. + 59. + 48. +^ 3 + +6 7 .3 + 7 + +�.9 - 4 W 1a+66 F .._ _ ( ? ; + 55.2 + 67.0 + 69.1 . . 1 F + 57 . + 66. + i 65. L + +64.;0 58.8 67.7 .6.9_1 63.4- S ATEa 54. - SUITE ; 4a _- + 99 50.9 1* ��.8 66.2 0.4 4 54- 1106'3.�F 64.� 58. + 2 45 _ _ + _ 4-... + -._- +67.5 69.6 64.7 + 5.6 59.8 +65.7 + 56. + + 46.5 5 .3W7 51.4 4 51. + 7 9 . 0 0. 59. 51- 39 8 71.2 62. r F6......- F6 I 4a b43. 6a 51. 48. 40. + 38.7 47.2 47.2 40.3 3 b -- '--- ` �.1 21.2 1 .5 20.2 2 5.2 21.2 18.2 19.1 2 El Um 5.8 21.3 18.4 16.9 19 - F1 4 5.1 + + + 21.2 1 .5 2 + + + + FLAG NOTES: 250VA MICRO INVERTER SUPPLIES EM POWER TO EMERGENCY LIGHTS IN LOBBY AND REGISTRATION. 250VA MICRO INVERTER SUPPLIES EM POWER TO EMERGENCY LIGHTS IN HALLWAY. 250VA MICRO INVERTER SUPPLIES EM POWER TO EMERGENCY LIGHTS IN CARE TEAM AND REAR HALLWAY. DAYLIGHT ZONE 26 $ + 4.1 + 6.01 29. 18.7 19.4 Fl 21.7 25.4 2 .0 . ' _ M 'i • F4:.:. . F6 - 32 T5 91. 3 6�, 35. 18.9'• .23:.- . 25.6 2.3. 22.0,. 6 24,.8' +2.1•. - 4.0 29.7 +27.3 30.6 4 I . TOILET ,. T ILET •. �'a .... -- : C MAN I:_i:;:_:::__... _ _ -------__ +f + * + 1+ ( 34 . 1 43.4 4 . 1 7..4 2¢�1 29.:.9. 31,.9X 31; 0 30: ��X (2 30.8 33.0 33.6.. 32. 1._... ....I M 4 _ - +. + + 34,2 43.3 4. 9 37:, 2.4.0.' .` 29..3. 3.0.•4 - . 27 4: 8 • 22`9:3' +2 .3 25.:. 32.7 35.0 .8 34 .7 0. I --..+: + i + 1.Y+ I. 3.2 1 91 . 2 6..35.. 6.0 .................5'':-7 1:8..;_.5_:_,_`2:.}. 4... +35. + -._._._...___.i. _ -___-- 2,+ 1L_ _�L.2 A� 2 8 .4 3 2 . 133.4 7.4 34.9 i DL$o 5. 4 17.5 6. 7 19.3 24.4 2�5 2 + .3 29 5 32.9 134.2 35.2 36.7 35. 30.8 Ff-__-- ; 1 1. 9 20.0 2 4. 2 5.0 +20.7 1 .2 20. 2$ g-- 2 6 -fr--Z -3 31.1 ^.,3. . 3 1.9 3 5. 3 3. 9 3 7. 4 3 2.6 I 2 it .:-- 4 8 20.9 1 .0 19.4 22.9 +23.2 . 19 3 1. 6 1 27 L _ _ 31' . 2' 3'S - 3 6. 0 C11� 3 7 3 3 7 6 3 2 7 � � �• a.: C1 L Y L J V 1 J. 'fes--y.,V.4 V 17 ,�,r....i•Hy�1_---• MN Lf) Lo LO �T -- 5 .8 6 2 64.7 -1 6 .2 5 5 .7 +6 v .1a 7 .6 +6 5 -F6_.___. LL 113 SF + 1 6 + . 0 7 .2 6 5-� F6 [U. _.._4......_._..._7 I 7 74.2 6 t -_74.5 �....... 6 CD CD F6 '5 .5 + +6 7 .3 + 7 + +�.9 + 51. in W 1a+66 F 64.9 a 43:•9' �i.4.:2 6 .2 6 ',8 . 5.8 21.3 18.4 16.9 19 - F1 4 5.1 + + + 21.2 1 .5 2 + + + + FLAG NOTES: 250VA MICRO INVERTER SUPPLIES EM POWER TO EMERGENCY LIGHTS IN LOBBY AND REGISTRATION. 250VA MICRO INVERTER SUPPLIES EM POWER TO EMERGENCY LIGHTS IN HALLWAY. 250VA MICRO INVERTER SUPPLIES EM POWER TO EMERGENCY LIGHTS IN CARE TEAM AND REAR HALLWAY. DAYLIGHT ZONE 26 $ + 4.1 + 6.01 29. 18.7 19.4 Fl 21.7 25.4 2 .0 . ' _ M 'i • F4:.:. . F6 - 32 T5 91. 3 6�, 35. 18.9'• .23:.- . 25.6 2.3. 22.0,. 6 24,.8' +2.1•. - 4.0 29.7 +27.3 30.6 4 I . TOILET ,. T ILET •. �'a .... -- : C MAN I:_i:;:_:::__... _ _ -------__ +f + * + 1+ ( 34 . 1 43.4 4 . 1 7..4 2¢�1 29.:.9. 31,.9X 31; 0 30: ��X (2 30.8 33.0 33.6.. 32. 1._... ....I M 4 _ - +. + + 34,2 43.3 4. 9 37:, 2.4.0.' .` 29..3. 3.0.•4 - . 27 4: 8 • 22`9:3' +2 .3 25.:. 32.7 35.0 .8 34 .7 0. I --..+: + i + 1.Y+ I. 3.2 1 91 . 2 6..35.. 6.0 .................5'':-7 1:8..;_.5_:_,_`2:.}. 4... +35. + -._._._...___.i. _ -___-- 2,+ 1L_ _�L.2 A� 2 8 .4 3 2 . 133.4 7.4 34.9 i DL$o 5. 4 17.5 6. 7 19.3 24.4 2�5 2 + .3 29 5 32.9 134.2 35.2 36.7 35. 30.8 Ff-__-- ; 1 1. 9 20.0 2 4. 2 5.0 +20.7 1 .2 20. 2$ g-- 2 6 -fr--Z -3 31.1 ^.,3. . 3 1.9 3 5. 3 3. 9 3 7. 4 3 2.6 I 2 it .:-- 4 8 20.9 1 .0 19.4 22.9 +23.2 . 19 3 1. 6 1 27 L _ _ 31' . 2' 3'S - 3 6. 0 C11� 3 7 3 3 7 6 3 2 7 � � �• a.: C1 L Y L J V 1 J. 'fes--y.,V.4 V 17 ,�,r....i•Hy�1_---• MN Lf) Lo LO �T -- b 7.5 55.1_ 55.9 50.5_. + 5.1 53.9 58.7 56.7 47. LO 0 LO dz -F6_.___. LL z O a F6 [U. E F6 CD CD W +5111 cts 9 +66.8 +�.9 + 51. in W 1a+66 4 64.9 a N _ F- O 00 rn SU E S' Z Y + +64.;0 58.8 67.7 .6.9_1 63.4- 5.9 60.123W5 54. - SUITE _..._............._. 116 SF 58.4 +67.5 69.6 64.7 + 5.6 59.8 +65.7 +64.8 56. + -T0 . 6 + 7 9 . 0 + 70.1 �:' 6 . r _ a...... ` �=---6� .! 8 71.2 62. r F6......- F6 F6_. .......... . 15113, 3.2 74.3 tu&. _+6'.7 2.sla 71.0 113.41a+5. 62.7 X61 + 4-.3-�51..4 . 59 6 +62.9 + 5•. __---- 451 SF ----- -13 .1 5.0 + 9 3 8 0. 2 3 7 28.1 2 .'1 0 2.. 33 3 4. 35.8 38 0 36.9 30.8 1 0 ix 3COPY 9.3 31 5'..'4 9r-9 . 1:'S . .33.6 34.4 36.2 3 36.5 29.7 SCAN 1 - 11 F .2b�. i 3 30.5 L. 7 25., 28.2 + 34.0 .4 i 30 1:� 32�.�2 ...34..5.:36.'7 38;,. 6.9 36.2 37. 35.3 29.3 , I :i t 18.7 4.0 4.6 0. 22.2 26.0 3'3.'1.:: .`7 43.8 40.0 36.0 35.1 34.4 30.2 �7. 1 YY� r ! { 34.2 90.3 41 4 4 .8 3 .6 .16. 2' :7.'' I 3 37.0'' 50.3 8.: 3' 4 i I `i :5 35 9 33.7 33. 9 30 8 " I 4 4T.7 .5 4 .7 .9 26.9.. '41..2. '.5 .:7:- 56 6••. :55'.'5 ." 2..:2' 44.3 35.5 31.3 30.8 28.2 r .. ' i +36.0 42.3 +43.3 +42 1-'1_- 3 7. 5 5• 2 5: 4:. • F8'. ZC. i3 2 - 2G �Gr --22. ------------ 71 -_--._._....__._.....__._...__.._.._._..._..._.__..__._.._.._.__._. _-_.. ................ 271.8 3 2. 2 +321. 9 2 4. 8 r _.._... _ ... _ ._.__._.._..- ... _............... .... $EVIEWED NPLIANG1 ,TPA 70 M AR 2 5 a i1T No. I Description Date LIGHTING PLAN PROJECT NUMBER 16036 DATE 03/11/2016 a cc a C: MN Lf) Lo LO v - N 00 N 00 LO 0 LO dz LL z O a U_ E CD CD W cts W in W N M N _ F- O 00 rn 0 U C° o S' Z Y No. I Description Date LIGHTING PLAN PROJECT NUMBER 16036 DATE 03/11/2016 a cc a C: P~ U) a C E a W C M U� W J W LI N C N U L O U) OI O) a C co C N E U O N C co i N L Q) cn U �, Flo Cn c E a w c Cu U� w J w J c a) U .c 7 0 UI 0 rn c c (D E 0 0 a c cc W ^N J Al EXTERIOR INTERIOR NEMA 3R NEMA 1 TO COMMERCIAL METER CENTER - ONE -LINE RISER DIAGRAM 12" = 1'-0" ELECTRICAL ROOM 2-112" EMT (4) 250KCMIL AL (1) #4G AL ------------- AREA ---- -----AREA OF WORK - --L- - - - - - - -- PANELPANEL j(SEC1) (SEC1) 200A 200A MLO MLO TENANT ELECTRICAL ROOM GENERAL NOTES 1. ALL CONDUCTORS ARE #12 AWG CU UNLESS NOTED OTHERWISE. MC FEEDER CAN BE USED WHERE APPROPRIATE AND AT CONTRACTOR'S DISCRETION. MC FEEDER SHALL BE SIZED PER NEC REQUIREMENTS. 2. RISER DIAGRAM IS NOT REPRESENTATIVE OF ACTUAL SWITCHBOARD LAYOUT. SEE ELECTRICAL ROOMS OR PANEL LOCATIONS (SHEET E2.01) AND PANEL SCHEDULES (SHEET E5.02) FOR PHYSICAL LAYOUT WITH RESPECT TO ACTUAL MANUFACTURED AND POTENTIAL INSTALLED CONDITIONS. 3. EQUIPMENT SHOWN BOLD IS NEW. 4. EQUIPMENT SHOWN DASHED IS EXISTING. 5. FIELD VERIFY EXISTING CONDITIONS PRIOR TO CONSTRUCTION. 6. ALL SWITCHBOARDS AND PANELBOARDS SUPPLIED BY A FEEDER SHALL BE MARKED TO INDICATE THE DEVICE OR EQUIPMENT WHERE THE POWER SUPPLY ORIGINATES PER NEC 408.4(B). 7. FEEDERS ARE ALUMINUM WITH THHNITHWN INSULATION. 8. PROVIDE PULL BOXES AS REQUIRED BY THE NEC. 9. SHORT CIRCUIT CURRENTS LESS THAN 10,000 AIC FOR 208V PANELS AND 14,000 AIC FOR 480V PANELS ARE NOT SHOWN. 10. THE ONE -LINE DIAGRAM IS DIAGRAMMATIC AND DOES NOT SHOW THE ACTUAL ROUTING OF RACEWAYS. 11. FOR TWO SECTION PANELS PROVIDE FULL SIZE FEEDER CONNECTIONS FROM SECTION 1 TO SECTION 2. 12. NOT ALL CIRCUIT BREAKERS ARE SHOWN, REFER TO PANEL AND SWITCHBOARD SCHEDULES FOR OTHER LOADS SERVED, AND SPARE CIRCUIT BREAKERS. REVIEWED COMPLIANDI NFPA 70 -1 MAR 2 5 No. I Description I Date E RISER DIAGRAM NG ®'V NI y� RO'JECT NUMBER 16036 C, co L 1 N NN ti co ti co M N M N U W z � o LL IL E U U ry Y_ U (U U) U U W ca w ~ J WCl M N � 00 M o U C° z Y ti No. I Description I Date E RISER DIAGRAM NG ®'V NI y� RO'JECT NUMBER 16036 C, r -d cn -v c E -a W c N U1 W J W LI V `0 v, 0I _0) c c0 G I V 0 0 (D c 0 cn L a) ^U) J A