Loading...
HomeMy WebLinkAboutPermit EL16-0244 - BLOCH RESIDENCE - SYSTEM MONITOR FOR SHOPBLOCH RESIDENCE 1166642 NDAVE S EL16-0244 City of Tukwila • Department of Community Development • 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Inspection Request Line: 206-438-9350 Web site: http://www.TukwilaWA.Rov ELECTRICAL PERMIT Parcel No: 3347400190 Permit Number: EL16-0244 Address: 11666 42ND AVE S Issue Date: 4/14/2016 International Residential Code Edition: Permit Expires On: 10/11/2016 Project Name: BLOCH RESIDENCE 2014 Owner: 2012 Name: BLOCH ANDREW M 2014 Address: 11666 42ND AVE S, TUKWILA, WA, 2012 98168 2012 Contact Person: 2012 Name: JON LANGE Phone: (206) 571-4729 Address: 4546 LEARY WAY NW, SEATTLE, WA, 98107 Date: `_ ` Contractor: Name: SUNERGY SYSTEMS INC Phone: (206) 297-0086 Address: 4546 LEARY WAY NW, SEATTLE, WA, 98107 License No: SUNERS1905D4 Expiration Date: Lender: Name: Address: , , , DESCRIPTION OF WORK: INSTALL ROOF MOUNTER PHOTOVOLTAIC ON DETACHED SHOP BUILDING. 6600 WATT AC OUTPUT OF GRID INTERACTIVE INVERTER, BACKFEED BREAKER IN 125 AMP SUBPANEL FED WITH A 40 AMP MAIN BREAKER, ADD CIRCUIT FOR SYSTEM MONITORING Valuation of single family: $9,774.00 Fees Collected: $106.48 Valuation of mf/comm: $0.00 Type of Work: SERV CHNG Electrical Service Provided by: SEATTLE CITY LIGHT Water District: TUKWILA Sewer District: TUKWILA SEWER SERVICE Current Codes adopted by the City of Tukwila: International Building Code Edition: 2012 National Electrical Code: 2014 International Residential Code Edition: 2012 WA Cities Electrical Code: 2014 International Mechanical Code Edition: 2012 WAC 296-466: 2014 Uniform Plumbing Code Edition: 2012 WA State Energy Code: 2012 International Fuel Gas Code: 2012 Permit Center Authorized Signature: Date: `_ ` I hearby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this development permit and agree o the conditions attached to this permit. ZSignature: Date: G Print Name: —1 This permit shall become null and void if the work is not commenced within 180 days for the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. PERMIT CONDITIONS: 1: 'ELECTRICAL PERMIT CONDITIONS' 2: A copy of the electrical work permit shall be posted or otherwise made readily accessible to the Electrical Inspector at each work site. 3: Approved plans shall be maintained at the construction site and shall be readily available to the Electrical Inspector. 4: All electrical work shall be in accordance with NFPA 70 - NEC, and requirements for electrical installations, Chapter 296-46B WAC. 5: When any portion of the electrical installation is to be hidden from view by permanent placement of parts of the building, such equipment shall not be concealed until it has been inspected and approved by the Electrical Inspector. 6: The issuance of an electrical work permit shall not be construed to be a permit for, or an approval of, any violation of the provisions of the electrical code or other ordinances of the jurisdiction. Permits or related documentation that presumes to grant this authority are therefore not valid. 7: Any change in the scope of work described by the electrical work permit shall require additional work permits. Where approved plans have been issued, revisions to the plans and additional review may be required. PERMIT INSPECTIONS REQUIRED Permit Inspection Line: (206) 438-9350 2100 ELECTRICAL FINAL 7003 ROUGH -IN ELECTRICAL 7002 SERVICE 7001 UNDERGROUND/SLAB CITY OF TUKWILA • Community Development Department Permit Center • 6300 Southcenter Blvd., Suite 100 Tulovila, WA 98188 hlM://www.TukwilaWA.gov Electrical Permit No. Ll Project No. Date Application Accepted: Date Application Expires: ::1— � 0 —T 1 For office use only) ELECTRICAL PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. "Please Print" SITE LOCATION King Co Assessor's Tax No.: Site Address: 11666 42nd Ave S Suite Number: Floor: Tenant Name: New Tenant: ❑ .....Yes ❑ ..No PROPERTY OWNER Name: Andrew Bloch Address: 11666 42nd Ave S City: Tukwila State: WA Zip: 98168 CONTACT PERSON — person receiving all project communication Name: jon lange Address: 4546 teary way nw City: seattle State: wa Zip: 98107 Phone: (206) 571-4726 Fax: Email: Valuation of Project (contractor's bid price): $ 9,774 ELECTRICAL CONTRACTOR INFORMATION Company Name: Sunergy Systems Address: 4546 Leary way NW City: seattle State: wa Zip: 98107 Phone: (206) 571-4726 Fax: Contr Reg No.: sunersi905d4 Exp Date: 03/17/2016 Tukwila Business License No.; Scope of Work (please provide detailed information): install roof mounted photovoltaic on detached shop building. 6600watt AC output of grid interactive inverter, backfeed breaker in 125a subpanel fed with a 40a main breaker. add circuit for system monitoring. Will service be altered? M Y Type of No Adding more than 50 amps? ❑ Yes m No Type of work: - " ❑ New ❑ Addition ❑ Service Change ❑ Low Voltage ❑ Generator ❑ Fire Alarm Property Served by: ❑ Puget Sound Energy ® Seattle City Light H:\Applications\Forms-Applications On Line\2014 ApplicationsMectrical Permit Application Revised 1-1-14.docx Revised: January 2014 bh ❑ Remodel m Tenant Improvement ❑ Telecommunication ❑ Temporary Service Pagel of 2 RESIDENTIAL NEW RESIDENTIAL. SERVICE ❑ New single family dwellings ...................................$152.85 (including an attached garage) ❑ Garages, pools, spas and outbuildings ........................ $81.90 ea ❑ Low voltage systems (alarm, furnace thermostat)................................$59.85 ea RESIDENTIAL REMODEL AND SERVICE CHANGES ❑ Service change or alteration ...................................... $81.90 $65.00 (no added/altered circuits) Temporary service (generator) ................................... ❑ Service change with added/altered circuits.................$81.90 Manufactured/mobile home service ........................... $86.25 number of added circuits ....................... $11.55 ea Circuits added/altered without service change ........... $54.60 $80.60 (up to 5 circuits) Number of concessions ......................... ❑ Circuits added/altered without service change ...........$54.60 Each ride and generator truck ............... $10.80 ea (6 or more circuits) ............................................... $7.65 ea ❑ Meter/mast repair ....................................................... $68.25 ❑ Low voltage systems ................................................. $59.85 (alarm, furnace thermostat) PERMIT APPLICATION NOTES - MULTI -FAMILY AND COMMERCIAL Fees are based on the valuation of the electrical contract. MISCELLANEOUS FEES ❑ Temporary service (residential) ................................. $65.00 ❑ Temporary service (generator) ................................... $80.90 ❑ Manufactured/mobile home service ........................... $86.25 (excluding garage or outbuilding) ❑ Carnivals.................................................................... $80.60 Number of concessions ......................... $10.80 ea Each ride and generator truck ............... $10.80 ea ***EFFECTIVE JANUARY I, 2014 EACH PERMIT WILL BE ASSESSED A 5% TECHNOLOGY FEE*** Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The Building Official may grant one extension of time for an additional period not to exceed 90 days. The extension shall be requested in writing and justifiable cause demonstrated. I HEREBY CERTIFY THAT 1 HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER OR ELECTRICAL CONTRACTOR: Print Name: Jon lange Mailing Address: 4546 leary way nw, seattle, wa 98107 H:\Applications\Forte-Applications On Line\2014 ApplicationsTleotrieal Permit Application Revised 1.1-14.docx Revised: January 2014 bb Date: 03/16/2016 Day Telephone: (206) 571-4726 City State Zip Page 2 of 2 DESCRIPTIONS PermitTRAK ACCOUNT QUANTITY PAID $106.48 EL16-0244 Address: 11666 42ND AVE S Apn: 3347400190 $106.48 ELECTRICAL $102.38 PERMIT FEE SINGLE FAMILY R000.322.101.00.00 0.00 $81.90 PLAN CHECK FEE 11000.345.832.00.00 0.00 $20.48 TECHNOLOGY FEE $4.10 TECHNOLOGY FEE TOTAL PAID R000.322.900.04.00 0.00 $4.10 1 Date Paid: Thursday, March 17, 2016 Paid By: JON LANGE Pay Method: CREDIT CARD 06236G Printed: Thursday, March 17, 2016 2:50 PM 1 of 1 I?WSYSTEMS INSPECTION RECORD i Retain a copy with permit INSPECTION N0. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Approved per applicable codes. 1:1 Corrections required prior to approval. (inspector: �/C� /�, / r ware: 0q1 REINSPECTION PEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. or NOTES: South facing array @ 5:12 pitch — 2 x 8 perlins at 24" O.C. spaced vertically. Access to perlins via inside of garage. Also can see TEK Solar components screws on roof outside except they are attached at every 48" instead of 24". Metal Roof — not standng seam Mounting: SunModo EZ Metal bases, with 2" posts and L -feet Racking: SunModo Rail — Helio Standard PSF: 2.4 lbs/sq.ft. Wind Zone: 1 (90 mph) Exposure Category: B DC Run: 40' —� 24" Access: gorilla ladder — — ltek Energy modules: _ 48 39.1 " x 64.8" t DRAWING NOT TO SCALE We vu+stratson mount 4-- oxiiLl I Rail Lengths: Thkk VW (A W far L fooe aM swAvi Ih mW dRecUsa 'Wd" usht sea Inverter, AC disconnect+ solar production meter to go on outside wall. Suboanel located inside of aam oo here �..; : •ti's q; :i!`>'• I REVILWE - - - - - - - MPLIANCE WITH _-- _-- PPA70 0 Nt=("-' RECEIVED --- --- — MAR 2 Cole CI Y OF TUKWILA MAR 17 2016 City of-TukwilF BUILDING DIVINF1..`\'R. RIVIIT CENTER 24 itek 285w-BLK modules - 2 strings of 12 modules into Solectria 6600 inverter Utility District: SCL CONFIDENTIAL, PROPERTY OF AHJ;SDPD Sunergy Systems Sunergy Systems 4546 Leary Way NW Seattle, WA 98107 Drawn By: 12 rails at 13' 8" Michael Po orzelski 6.84 kW Itek/Solectria-Itek Photovoltaics stem Electrical Admin. Approval: Title/Part/Descrition: Jon Lange, NABCEP 11666 42nd Ave. S., Date: 3/16/2016 Tukwila, WA 98168 PV ROOF PLAN 39.1 16.5" aJ v (D ITEK 42 lbs (2.4 lbs/ sq.ft.) EL l We vu+stratson mount 4-- oxiiLl I Rail Lengths: Thkk VW (A W far L fooe aM swAvi Ih mW dRecUsa 'Wd" usht sea Inverter, AC disconnect+ solar production meter to go on outside wall. Suboanel located inside of aam oo here �..; : •ti's q; :i!`>'• I REVILWE - - - - - - - MPLIANCE WITH _-- _-- PPA70 0 Nt=("-' RECEIVED --- --- — MAR 2 Cole CI Y OF TUKWILA MAR 17 2016 City of-TukwilF BUILDING DIVINF1..`\'R. RIVIIT CENTER 24 itek 285w-BLK modules - 2 strings of 12 modules into Solectria 6600 inverter Utility District: SCL CONFIDENTIAL, PROPERTY OF AHJ;SDPD Sunergy Systems Sunergy Systems 4546 Leary Way NW Seattle, WA 98107 Drawn By: 12 rails at 13' 8" Michael Po orzelski 6.84 kW Itek/Solectria-Itek Photovoltaics stem Electrical Admin. Approval: Title/Part/Descrition: Jon Lange, NABCEP 11666 42nd Ave. S., Date: 3/16/2016 Tukwila, WA 98168 PV ROOF PLAN d d C C _ a, a t L. O x +• m Of ` C � O w � O _ y •0 ;o a i E =m•4) 3 �•t � � � i 1 - _ ewe, C c II Ap VOC calculation: Module temp. coefficient: .1 23V / C Record Low: -8C DeltaT: 33C 33 ' .123 = 4.06v 39.3 + 4.06v = 43.36 43.36 ' 12 modules = 520VOC V PV Module 1 VPV Module 1 .IQ + + II _ fI PV Module 2 PV Module 2 I + + i Red PV Module 3 PV Module 3 a a V • 3 EMT-%" d #10 awg PV Module .2 V PV Module 12 THWN-2, + I + I Copper I 1 I 1 I 1 _ I I I 1 RECEIVED ��1 .f'CITY OF i't KWILA � MAR 117 2036 PERMIT CENTER Black MODULEt EQUIPMENT CONTINUOUS Grounding — GROUNDUL listed/NEC Electrode Conductor— compliant, Un rac Ground systenj #6 awg, bare Copper NOTES: 1. ALL SERIES CONNECTED PV MODULES SHALL BE INTERCONNECTED WITH MANUFACTURER SUPPLIED MC -4 GENERATION 2, LOCKING CONNECTORS. 2. PV SOURCE CIRCUIT JUNCTION BOX SHALL BE LOCATED ON THE ROOF AND NEMA 3R RATED. 3. ALL WIRES FROM ROOF JUNCTION BOX TO INVERTER SHALL BE 10AWG.THHN-2 AND IN CONDUIT TO MEET NEC CODE AND LIMIT VOLTAGE DROP TO LESS THAN 2%. 4. WIRING IN DC CIRCUITS TO BE RATED 600V -90C, EXPOSED CABLES SUNLIGHT RESISTANT. 5. PV SYSTEM Voc SHALL NEVER EXCEED 600 VDC (using historic lowest temperature for safety factor). 6. INVERTERS INTEGRAL, LOCKABLE DC DISCONNECT SHALL BE USED AS THE PV SYSTEM DC DISCONNECT. 7. INVERTER SHALL BE LOCATED NW CORNER OF DETACHED SHOP, SYSTEM COMPONENTS CLEARLY LABELED. 8. PRODUCTION METER SHALL BE LOCATED NW CORNER OF DETACHED SHOP. 9. WIRING FROM INVERTER TO SOLAR METER AND P L THWN IN CONDUIT. 10. PV MODULE CONTINUOUS GROUNDI�I� CQNDt1� I12AC UL/ETL LISTED SOLAR MOUNT GR PNDING TO RACKING RACKING GROUNDING Ea3 Vlq IbU011&iA . B NTINUOUS COPPER. 2 24 MODULE PV ARRAY (6.84kW STC) ITEK ITE HE285- (2 Strings of 12) BILK Series String characteristics PV Modules Voc= 520V, Vmpp=389V, Imp=8.7A, 285W/32.4V/8.7A Isc=2x(9.4x1.25) = 23.5A Voc=39.3v, - ---ES IV City ofyTuWla M Isc=9.4A VOC calculation: Module temp. coefficient: .1 23V / C Record Low: -8C DeltaT: 33C 33 ' .123 = 4.06v 39.3 + 4.06v = 43.36 43.36 ' 12 modules = 520VOC V PV Module 1 VPV Module 1 .IQ + + II _ fI PV Module 2 PV Module 2 I + + i Red PV Module 3 PV Module 3 a a V • 3 EMT-%" d #10 awg PV Module .2 V PV Module 12 THWN-2, + I + I Copper I 1 I 1 I 1 _ I I I 1 RECEIVED ��1 .f'CITY OF i't KWILA � MAR 117 2036 PERMIT CENTER Black MODULEt EQUIPMENT CONTINUOUS Grounding — GROUNDUL listed/NEC Electrode Conductor— compliant, Un rac Ground systenj #6 awg, bare Copper NOTES: 1. ALL SERIES CONNECTED PV MODULES SHALL BE INTERCONNECTED WITH MANUFACTURER SUPPLIED MC -4 GENERATION 2, LOCKING CONNECTORS. 2. PV SOURCE CIRCUIT JUNCTION BOX SHALL BE LOCATED ON THE ROOF AND NEMA 3R RATED. 3. ALL WIRES FROM ROOF JUNCTION BOX TO INVERTER SHALL BE 10AWG.THHN-2 AND IN CONDUIT TO MEET NEC CODE AND LIMIT VOLTAGE DROP TO LESS THAN 2%. 4. WIRING IN DC CIRCUITS TO BE RATED 600V -90C, EXPOSED CABLES SUNLIGHT RESISTANT. 5. PV SYSTEM Voc SHALL NEVER EXCEED 600 VDC (using historic lowest temperature for safety factor). 6. INVERTERS INTEGRAL, LOCKABLE DC DISCONNECT SHALL BE USED AS THE PV SYSTEM DC DISCONNECT. 7. INVERTER SHALL BE LOCATED NW CORNER OF DETACHED SHOP, SYSTEM COMPONENTS CLEARLY LABELED. 8. PRODUCTION METER SHALL BE LOCATED NW CORNER OF DETACHED SHOP. 9. WIRING FROM INVERTER TO SOLAR METER AND P L THWN IN CONDUIT. 10. PV MODULE CONTINUOUS GROUNDI�I� CQNDt1� I12AC UL/ETL LISTED SOLAR MOUNT GR PNDING TO RACKING RACKING GROUNDING Ea3 Vlq IbU011&iA . B NTINUOUS COPPER. 2 MARKING/LABELING PER NEC 690 meter: 292221 �/I �? j 2016 200a 1201 SERVICE 120/240 VAC 1¢' SOLAR kWh METER FOR PRODUCTION FROM UTILITY --••. - ---ES IV City ofyTuWla M Rtiji .nimC7 01V1 I L" 1 2 " 1 2 FEN 2 240 VAC 1 11• GFOI MIW 6.6kW INVERTER 60HZ, 8 200a h PROTECTION Solectria 27.5AAC(max) main NEMA °/. r � 6600Wmp ' t P ane 3RAC DIGITAL DISPLAY OUTPUT Junction I ;L., Q — MPP 1 1 -LINE - - - - Box I• ` 40A •--•- ' PP7N T2 LINE 1 - r _ 0 i > I GND 1 I I OOO W DC 9 125a DISCONNECT — CHBR G O = SWITCH ® 40A sub - I I I #8 THWN, CU O Panel I I I — -------------- I I i--------------- NEMA 3R- 60ampAC I Locking Disconnect —_ 1 Visible -Break. GND ROD I I CONFIDENTIAL, PROPERTY OF I Utility: SCL SunergySystems Sunergy Systems I G, D ;ac ZI AHJ: Tukwila cult: Bloch, Andrew I C 3 2 Revised: 3116/16 Project: - - _ —I o i o Jon Lan a NABCEP 6.84kW Itek/Solectria-MIW Photovoltaics stem z N Drawn by: Howard Lamb, MSEE Site Address: rue/Part/Descrition: G ElectricalEngineerLambpMSE Howard Lamb, MSEE 11666 42nd Ave S PV MODULE ELECTRICAL Date: 12/04/15 Tukwila, WA 98168 CONFIGURATION DRAWING lw k ms's W. co IM OIL UJ � N UJ O LL Wo ZE W as CL c cr cc( a co IM OIL a 0 0 0 0 CO Nb 4 14 1 T� i iv .ow Nb 4 ul:3 1 T� i .ow PERMIT COORD COPY PLAN REVIEW/ROUTING SLIP PERMIT NUMBER: EL16-0244 PROJECT NAME: BLOCH RESIDENCE SITE ADDRESS: 11666 42 AVE S X Original Plan Submittal DATE: 03/17/16 Revision # before Permit Issued Response to Correction Letter # Revision # after Permit Issued DEPARTMENTS: J $ A?P Building Division aFire Prevention ❑ Planning Division ❑ Public Works ❑ Structural ❑ Permit Coordinator PRELIMINARY REVIEW: DATE: 03/22/16 Not Applicable ❑ Structural Review Required ❑ (no approval/review required) REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: DUE DATE: 04/19/16 Approved ❑ Approved with Conditions ❑ Corrections Required ❑ Denied ❑ (corrections entered in Reviews) (ie: Zoning Issues) Notation: REVIEWER'S INITIALS: DATE: Perinit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: 12/18/2013 Sunergy Systems Inc. Horne Espanol Contact Safety & Health Claims & Insurance Washington Mate Department of Labor ,& Industries Sunergy Systems Inc. Owner or tradesperson 4546 Leary Way NW SEATTLE, WA 98107 Principals 206-297-0086 David Kissinger, PRESIDENT KING County Howard Lamb, VICE PRESIDENT Doing business as Sunergy Systems Inc. WA UBI No. Business type 602 923 081 Corporation License Page I of 2 Search L&I A-7. Inc Workplace Rights Verify the contractor's active registration / license / certification (depending on trade) and any past violations. Electrical Contractor Active. ............................................................... Meets current requirements. License specialties GENERAL License no. SUNERS1905D4 Effective — expiration 04/08/2010— 04/09/2018 Designated administrator .................... Lange, Jon Damon License type Electrical Administrator Bond ................. Lexon Insurance Company Bond account no. 9801597 Received by L&I Active. Meets current requirements. License no. LANGEJD860DQ $4,000.00 Effective date https://secure.lni.wa.gov/verify/Detail.aspx?UBI=602923081&LIC=SUNERS1905D4&SAW= 4/14/2016