Loading...
HomeMy WebLinkAboutPermit EL16-0315 - DIECUT PRINTERS - PANEL, LIGHTING AND OUTLETSThis record contains information which is exempt from public disclosure pursuant to the Washington State Public Records Act, Chapter 42.56 RCW as identified on the Digital Records Exemption Log shown below. EL16-0315 DIECUT PRINTERS 345 ANDOVER PARK E SUITE 100 RECORDSDIGITAL D-) EXEMPTION LOG THE ABOVE MENTIONED PERMIT FILE INCLUDES THE FOLLOWING REDACTED INFORMATION Page # Coda Exemption, � � � I3ri6f Explanatory 6escrlofion, Sfatutte/Ruilo The Privacy Act of 1974 evinces Congress' intent that social security numbers are a private concern. As such, individuals' social security Personal Information — numbers are redacted to protect those Social Security Numbers individuals' privacy pursuant to 5 U.S.C. sec. 5 U.S.C. sec. DR1 Generally — 5 U.S.C. sec. 552(a), and are also exempt from disclosure 552(a); RCW 552(a); RCW under section 42.56.070(1) of the Washington 42.56.070(1) 42.56.070(1) State Public Records Act, which exempts under the PRA records or information exempt or prohibited from disclosure under any other statute. Redactions contain Credit card numbers, debit card numbers, electronic check numbers, credit Personal Information — expiration dates, or bank or other financial RCW 13 DR2 Financial Information — account numbers, which are exempt from 42.56.230(5) RCW 42.56.230(4 5) disclosure pursuant to RCW 42.56.230(5), except when disclosure is expressly required by or governed by other law. Personal Information — Redactions contain information used to prove RCW DR3 Driver's License. — RCW identity, age, residential address, social security 42.56.230 (7a 42.56.230 number or other personal information required to & c) (7a & c) apply for a driver's license or identicard. Redacted content contains a communication between client and attorney for the purpose of obtaining or providing legal advice exempt from RCW Attorney -Client Privilege — disclosure pursuant to RCW 5.60.060(2)(a), 5.60.060(2)(a); DR4 RCW 5.60.060(2)(a); RCW which protects attorney-client privileged RCW 42.56.070(1) communications, and RCW 42.56.070(1), which 42.56.070(1) protects, under the PRA, information exempt or prohibited from disclosure under another statute. DIECUT PRINTERS 345 ANDOVER PARK E SUITE 100 EL16-0315 City of Tu kwi la • Department of Community Development + 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Inspection Request Line: 206-438-9350 Web site: http://www.TukwilaWA.eov ELECTRICAL PERMIT Parcel No: 0223400040 Permit Number: EL16-0315 Address: 345 ANDOVER PARK E 100 Issue Date: 6/8/2016 International Residential Code Edition: Permit Expires On: 12/5/2016 Project Name: DIECUT PRINTERS 2014 Owner: 2012 Name: SRO PROPERTIES INC 2014 Address: 14114TH AVE #1315, SEATTLE, WA, 2012 98101 2012 Contact Person: 2012 Name: KENT VANDERWEIDE Phone: (425) 788-7710 Address: PO BOX 100, DUVALL, WA, 98019 Contractor: Name: ZORKO ELECTRIC INC Phone: (425) 788-7710 Address: PO BOX 100, DUVALL, WA, 98019 License No: ZORKOE11210K Expiration Date: 9/12/2016 Lender: Name: Address: DESCRIPTION OF WORK: TENANT IMPROVEMENT. ADD ONE 200 AMP 120/208/3p PANEL. INSTALL NEW LIGHTING AND OUTLETS AS SHOWN. PROVIDE CONNECTIONS TO NEW HVAC EQUIPMENT Valuation of single family: $0.00 Fees Collected: $2,027.54 Valuation of mf/comm: $94,702.00 Type of Work: TENANT IMP Electrical Service Provided by: PUGEST SOUND ENERGY Water District: TUKWILA Sewer District: TUKWILA Current Codes adopted by the City of Tukwila: International Building Code Edition: 2012 National Electrical Code: 2014 International Residential Code Edition: 2012 WA Cities Electrical Code: 2014 International Mechanical Code Edition: 2012 WAC 296-4613: 2014 Uniform Plumbing Code Edition: 2012 WA State Energy Code: 2012 International Fuel Gas Code: 2012 0.1d4 Permit Center Authorized Signature: Date:—ol w I hearby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this development permit and agree to the conditions attached to this permit. Signa // Dater Print This permit shall become null and void if the work is not commenced within 180 days for the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. PERMIT CONDITIONS: 1: 'ELECTRICAL PERMIT CONDITIONS' 2: A copy of the electrical work permit shall be posted or otherwise made readily accessible to the Electrical Inspector at each work site. 3: Approved plans shall be maintained at the construction site and shall be readily available to the Electrical Inspector. 4: All electrical work shall be in accordance with NFPA 70 - NEC, and requirements for electrical installations, Chapter 296-46B WAC. S: When any portion of the electrical installation is to be hidden from view by permanent placement of parts of the building, such equipment shall not be concealed until it has been inspected and approved by the Electrical Inspector. 6: The issuance of an electrical work permit shall not be construed to be a permit for, or an approval of, any violation of the provisions of the electrical code or other ordinances of the jurisdiction. Permits or related documentation that presumes to grant this authority are therefore not valid. 7: Any change in the scope of work described by the electrical work permit shall require additional work permits. Where approved plans have been issued, revisions to the plans and additional review may be required. PERMIT INSPECTIONS REQUIRED Permit Inspection Line: (206) 438-9350 2100 ELECTRICAL FINAL 7003 ROUGH -IN ELECTRICAL 7002 SERVICE 7001 UNDERGROUND/SLAB CITY OF TUBW _ Community Development Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://www.TukwilaWA.gov SITE LOCATION Electrical Permit No. L L! b— n i t s Project No. Date Application Accepted: AA -1, rp Date Application Expires: or o ce use on ELECTRICAL PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. "Please Print" King Co Assessor's Tax No.: Site Address: 345 Andover Park East Suite Number: Floor: Tenant Name: Diecut Printers New Tenant: 0 .....Yes ❑ ..No PROPERTY OWNER Name: Diecut Printers Address: 345 Andover Park East City: Tukwila State: WA Zip: CONTACT PERSON — person receiving all project communication Name: Kent VanderWeide Address: PO Box 100 City: Duvall State: WA Zip: 98019 Phone: (425) 788-7710 Fax: (425) 788-7730 Email: kenty@zorkoelectric.com ELECTRICAL CONTRACTOR INFORMATION Company Name: Zorko Electric Inc. Address: PO Box 100 City: Duvall State: WA -Zip: 98019 Phone: (425) 788-7710 Fax: (425) 788-7730 Contr Reg No.: ZORKOEI121 OR Exp Date: 09/12/2016 Tukwila Business License No.; BUS -0996996 Valuation of Project (contractor's bid price): $ 94,702 Scope of Work (please provide detailed information): Tenant improvement. Add one 200a 120/208/3p panel. Install new lighting and outlets as shown. Provide connections to new HVAC equipment Will service be altered? ❑ Yes Type of Use: Office/production m No Adding more than 50 amps? ❑ Yes No Type of work: ❑ New ❑ Addition ❑ Service Change ❑ Remodel 0 Tenant Improvement ❑ Low Voltage ❑ Generator ❑ Fire Alarm ❑ Telecommunication ❑ Temporary Service Property Served by: 52 Puget Sound Energy ❑ Seattle City Light HAAntiationsTormt-Applications On Linc\2014 AppliatiomMechial Permit Application Revised 1-1-14.4ocx Revised. January 2014 bb Page 1 of 2 !/ RESIDENTIAL NEW RESIDENTIAL SERVICE ❑ New single family dwellings ................................... $152.85 (including an attached garage) ❑ Garages, pools, spas and outbuildings ........................$81.90 ea ❑ Low voltage systems (alarm, furnace thermostat) ................................ $59.85 ea RESIDENTIAL REMODEL AND SERVICE CHANGES ❑ Service change or alteration ...................................... $81.90 ❑ (no added/altered circuits) $80.90 ❑ Service change with added/altered circuits ................. $81.90 number of added circuits ....................... $11.55 ea ❑ Circuits added/altered without service change ........... $54.60 (up to 5 circuits) $10.80 ea ❑ Circuits added/altered without service change ........... $54.60 (6 or more circuits) ............................................... $7.65 ea ❑ Meter/mast repair ....................................................... $68.25 ❑ Low voltage systems ................................................. $59.85 (alarm, furnace thermostat) PERMIT APPLICATION NOTES - MULTI -FAMILY AND COMMERCIAL Fees are based on the valuation of the electrical contract. MISCELLANEOUS FEES ❑ Temporary service (residential) ................................. $65.00 ❑ Temporary service (generator) ................................... $80.90 ❑ Manufactured/mobile home service ........................... $86.25 (excluding garage or outbuilding) ❑ Carnivals....................................................................$80.60 Number of concessions ......................... $10.80 ea Each ride and generator truck ............... $10.80 ea ***EFFECTIVE JANUARY 1, 2014 EACH PERMIT WILL BE ASSESSED A 5% TECHNOLOGY FEE*** Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The Building Official may grant one extension of time for an additional period not to exceed 90 days. The extension shall be requested in writing and justifiable cause demonstrated. I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. Date: 04/08/2016 Print Name: Kent Vandeffeide Day Telephone: (425) 788-7710 Mailing Address: PO Box 100 Duvall WA 98019 City state zip MApplicationsWorms-Applications On Line\2014 ApplicationsWectrical Permit Application Revised 1-1-14.docx Revised: January 2014 bh Page 2 of 2 DESCRIPTIONS ACCOUNT QUANTITY PAID PermitTRAK $2,027.54 EL16-0315 Address: 345 ANDOVER PARK E 100 Apn: 0223400040 $2,027.54 ELECTRICAL $1,949.56 PLAN CHECK FEE R000.345.832.00.00 0.00 $389.91 PERMIT FEE MULTI-FAM/COMM R000.322.101.00.00 0.00 $1,559.65 TECHNOLOGY FEE $77.98 TECHNOLOGY FEE !!TOTAL FEES PAID BY RECEIPT: R8152 R000.322.900.04.00 0.00 $77.98 i Date Paid: Friday, April 08, 2016 Paid By: KENT VANDERWEIDE Pay Method: CREDIT CARD 091655 Printed: Friday, April 08, 2016 1:53 PM 1 of 1 (C -PW SYSTEMS INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Project: fA/ Type of Inspection: M A)l li Address: AP 6 Date Called: Special Instructions: Date Wanted: a.m .m. �' e�( i R Pn el o� Requester: Phone No: n rVT Approved per applicable codes. Corrections required prior to approval. U paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. INSPECTION RECORD J Retain a copy with permit 'Qf INSPECTION NO. I' RMIT 4 0. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Project: ��/ ,� t ��,p f l(� Dr f- �, Type of Inspection Address: , /�� Date Called: Special Instructions: Date Wanted: YAJ a.m p.m. Requester: Phone No: l 71 � 1 6 f� Approved per applicable codes. Corrections required prior to approval. I --- XotI44- ✓41 6W I Inspector: "70 N46t— Nate: I®p/'-3 h(, I REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. INSPECTION RECORD Retain a copy with permit 64oml INSPECTION N0. PERMIT NO. CITY K I UILDIIVG DIVISION OF TU W LA B 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 - Project: � f Type of Inspection: Address: _` �J— Date Called: Special Instructions:®U Date Wanted: ap m Requester: /�J /QA/ Phone No: 31 DApproved per applicable codes. 1:1 Corrections required prior to approval. LJ paid at 6300 Southcenter Blvd., Suite 100. Cali to schedule reinspection. / INSPECTION RECORD 2 Retain a copy with permit i�©J�S INSPECTION NO. PERMIT NO, . CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Project: Type of Inspection: TO lJ� � / Address: � , /� / " Date Called: Special Instructions: Date Wanted:7 a. Lzo p.m. Requester: Phone No: 3t, Q 0 Approved per applicable codes. Q Corrections required prior to approval. LJ paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. PERMIT COCRD COPY PLAN REVIEW/ROUTING SLIP PERMIT NUMBER: EL16-0315 DATE: 04/08/16 PROJECT NAME: DIECUT PRINTERS SITE ADDRESS: 345 ANDOVER PARK E X Original Plan Submittal Revision # before Permit Issued Response to Correction Letter # Revision # after Permit Issued DEPARTMENTS: Building Division Fire Prevention ❑ Planning Division ❑ Public Works ❑ Structural ❑ Permit Coordinator PRELIMINARY REVIEW: DATE: 04/12/16 Not Applicable ❑ Structural Review Required ❑ (no approval/review required) REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: DUE DATE: 05/10/16 Approved ❑ Approved with Conditions Corrections Required ❑ Denied ❑ (corrections entered in Reviews) (ie: Zoning Issues) Notation: REVIEWER'S INITIALS: DATE: Perinit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: 12/18/2013 ZORKO ELECTRIC INC Page 1 of 2 Home Espafiol Cont:aet Search L&I :I A Z Index Help A"Ty I'm Safety & Health Claims & Insurance Workplace Rights Trades & Licensing (D Washington State Department of Labor & Industries ZORKO ELECTRIC INC Owner or tradesperson PO BOX 100 DUVALL, WA 98019 Principals 425-788-7710 VANDERWEIDE, KENT, PRESIDENT KING County VANDERWEIDE, KENT, AGENT Doing business as ZORKO ELECTRIC INC WA UBI No. Business type 601 099 999 Corporation License Verify the contractor's active registration / license / certification (depending on trade) and any past violations. Electrical Contractor Active. ................................ _................._.... Meets current requirements. License specialties GENERAL License no. ZORKOE11210K Effective — expiration 09/12/1988— 09/12/2016 Designated administrator VANbERWbbC KENT License type Master Electrician Bond ................. No bond accounts during the previous 6 year period. Savings ................... (in lieu of bond) Received by L&I Release date N/A Savings account ID Active. Meets current requirements. License no. VANDEK'975CS $4,000.00 Effective date 06/19/1996 Impaired date N/A Savings history License Violations .............................--- .................. Infraction no. ERADWO0258 Satisfied ....................... Issue date RCWIWAC 04/13/2012 19.28.101 RCW Violation city Violation amount Duvall $4,000.00 https://secure.Ini.wa.gov/verify/Detail.aspx?UBI=601099999&LIC=ZORKOEI121OK&SAW= 4/27/2016 LIGHTING FIXTURE SCHEDULE: ID STYLE MANUFACTURER ITEM NUMBER FINISH LAMPING VOLTAGE WATTS PER QUANTITY TOTAL WATTAGE NOTES We � SHOWN ARE NEW) FAN - NEW <EXIT EXIT SIGN W/ DIRECTIONAL FIXTURE ARROWS - NEW EXIT EXIT SIGN WITH EMERGENCY A PENDANT INDIRECT/DIECT - 59M -P LIGHTCONTROL 59M -P -ID -04 -BW -CX -2T5 WHITE (2) T5 120 120 47 5640 113 B 2 X 4 RECE55ED TROFFER FOCAL POINT 4 LUNA CENTER BASKET LUMIRATIZE WHITE LED 120 69 44 3036 1 C RECESSED CAN LIGHTOLIER # 1104F2632ES FRAME -IN KIT w/ #1171 TRIM WHITE (1) 20W TRIPLE TUBE 4 -PIN CFL 120 120 4 480 1 D EXIT SIGN HUBBELL LIGHTING DUAL LITE - HCX SERIES HCXUGW-03L WHITE FACE wl LETTERS GREEN(1)1W LED 120 10 3 30 2 E EXIT SIGN DIRECTIONAL HUBBELL LIGHTING DUAL LITE - EVC SERIES EVCUGWD WHITE FACE w REN LETTERS (1)1W LED 120 1.65 2 3.3 1 F WALL VALENCE LITE CONTROL V3 ADJUSTABLE WALL VALENCE 34-W WHITE (1) 2T5 120 26 3 78 1 G EMERGENCY LIGHTING LITHONIA LIGHTING 1LED T PLASTIC EMERGENCY LIGHTING E WHITE (1) 2T5 120 1.44 5 7.2 1 NOTES: 1. VERIFY WITH OWNER PRIOR TO ORDERING. 2. MOUNT ABOVE DOOR 3. SUSPEND 11'-0" FROM FLOOR. i RCP - MAIN FL001Z 1/8" = V-0° TOTAL INTERIOR WATTAGE: 9196.5 ..... _.__._.-....D 9 (e) 0 4' 8' 16' REFLECTED CEILING PLAN LEGEND: 2 x 4 RECESSED FLUORESCENT FIXTURE - NEW 1 x 4 SUSPENDED FLUORESCENT U=j FIXTURE - NEW 0 RECESSED CAN - NEW z w O LIGHT SWITCH (ALL LOCATIONS We � SHOWN ARE NEW) FAN - NEW <EXIT EXIT SIGN W/ DIRECTIONAL ARROWS - NEW EXIT EXIT SIGN WITH EMERGENCY W LIGHTING - NEW >❑4 EMERGENCY LIGHTING - NEW NOTES: 1) INSTALL MOTION DETECTION LIGHT SWITCHES IN OFFICE AS REQUIRED BY CODE. 2) INSTALL DIMMER SWITCH FOR RECEPTION AREA LIGHTING. 3) NEW LIGHTING THROUGHTOUT. No changes shall be made to the scop of v ►orlc without prior approval of u!v_1di!a Building Division. UO i : wiil require a new plan submittal .nd may ixliuda additional plan review fees. Fl�� r�3i�t�� �-�,•�•FRE Copy 4�! is gui� Y �'; ► ' jest to errors and o =iii;-ri;ioii C3C)ct6fi1Onts deco not a(I,ll_I0 z0 V °3 vIci c"If t'� l aL opt'&_i cods) or ordinance . I"r cc in 11P ':jald y and conditio;l:, ij acknoWoadycd: ®ate City Of Tukwila BUILDING DIVISI PFMMIT FOR: ecnanicai 1 J Elco irlcal L-P'i''Iumbing (1-o�rh Piping lJ1 l/ Of Tukwila DIVISION_) -REVIEWED .FOR COMPLIANCE WITH NFPA 70 M NEC APR 2 5 2016 RECEIVED CITY OF TUKWILA APR 0 8 2016 PERMIT CENTER Zorko Electric, Inc. P.O. Box 100 Duvall, WA 98019 425-788-7710 425-788-7730 fax E1.1 H U=j W 1�= 2 z w O We � - o37 F— Z V z W LL' O E1.1 a U I I I • I , I I , r � I I I , I ( I I ( � � I I , l.0 _._....... _.. .......m_. _ __-._. _.. ....._.I._'" .- _--__ -.. ___._.... .._• '-___ ._. ...__-_ _.. _�__ .- __.._....._ ..... ._._........ ... ......_.. ._ _._._..._ _ __._m.._ .... .._.._._. ..., ................ ..... POWER /DATA PLAN -MAIN FLOOR 1/8" = 1'-0" J i F'� �..._ -- l - -----.-OE POWER & DATA PLAN LEGEND: 0 DUPLEX RECEPTACLE 3z DATA / PHONE (2 CAT 6 PLENUM RATED CABLES) GENERAL NOTES: 1) ALL RECEPTACLES ARE NEW. 2) CONTRACTOR SHALL COORDINATE WITH TENANT'S LOW - VOLTAGE / ITVENDOR. 3) NEW SWITCHES SHALL BE LEVITON DECORA IN WHITE. 4) PROVIDE DEDICATED DUPLEX FOR COPIER'S AND MICROWAVE THROUGHOUT OFFICE AS NEEDED. COORDINATE WITH OWNER REVIEWED I UH COMPLIANCE WITH IPPA 70 w NEC APR 2 5 2015 A RECEIVED CITY OF TUKWILA APR 0 8 2016 PERMIT CENTER 7;A,e alationS1NCE 1945 0 ; 0 Zorko Electric, Inc. P.O. Box 100 Duvall, WA 98019 425-788-7710 425,-788,-7730 fax Q) O U 4-+ O N a-+ Q Q J_ Q W re Q U-0 W O 0 z dC L0 d- M n zs� i t� t);::843Lh • Q) O U 4-+ O N a-+ Q Q J_ Q W re Q U-0 W O 0 z dC L0 d- M n zs� i t� t);::843Lh NEW PANEL: L2 125% A B c I I I I I I I I 1 1 1 1 2 3 1 1 1 4 5 1 1 1 6 7 1 1 1 8 9 1 1 1 10 11 1 1 1 12 13 1 1 1 14 15 1 1 1 16 17 1 1 1 18 19 1 1 1 20 21 1 1 1 22 23 1 1 1 24 25 1 1 1 26 27 1 1 1 28 29 1 1 1 30 31 1 1 1 32 33 1 1 1 34 35 1 1 1 36 37 1 1 1 38 39 1 1 1 40 41 1 1 1 42 kva 120/208/3ph FLUSH AIC: 22,000 200a MLO CIRCUITDESCRIPTION KVA AMP AMP KVA CIRCUIT DESCRIPTION Production Lighting 1.5 20 60 6.3 Appliance Recept Production Lighting 1.5 20 60 6.3 RTU -1 Production Lighting 1.5 20 60 6.3 Appliance Recept Production Lighting 1.5 20 20 1.5 Production Recepts Office Recepts 1.1 20 20 1.5 Production Recepts Office Recepts 1.1 20 20 1.5 Production Recepts Office Recepts 1.1 20 20 1.5 Production Recepts Office Recepts 1.1 20 20 1.5 Production Recepts Office Recepts 1.1 20 20 1.5 Production Recepts Office Recepts 1.1 20 20 1.5 Production Recepts Office Recepts 1.1 20 20 1.5 Production Recepts Office Recepts 1.1 20 20 1.5 Production Recepts Office Recepts 1.1 20 20 0.8 Production Recepts Office Recepts 0.7 20 20 20 20 20 20 Compliance by Building Area 20 20 Total Allowed Watts Total Proposed Watts Interior Lighting Power Allowance Manufacturing facilltv 20 20 5896 COMPLIES Office 20 20 COMPLIES 20 20 20 20 Connected Load: 44.4 kva Demand Load: 50.5 kva 123 amp 140.4 amp Load Calculation Light ing: HVAC: Unit 1 General Power Out lets: Production Recepts Hot Water Appliance Recepts Exist ing Loads: Watts EXISTING PANEL: L1 125% A B c I I I 1 1 1 I I I 1 1 1 1 2 3 1 1 1 4 5 1 1 1 6 7 1 1 1 8 9 1 1 1 10 11 1 1 1 12 13 1 1 1 14 15 1 1 1 16 17 1 1 1 18 19 1 1 1 20 21 1 1 1 22 23 1 1 1 24 25 1 1 1 26 27 1 1 1 28 29 1 1 1 30 31 1 1 1 32 33 1 1 1 34 35 1 1 1 36 37 1 1 1 38 39 1 1 1 40 41 1 1 1 42 kva 120/208/3ph FLUSH AIC: 22,000 150a M MLO CIRCUIT DESCRIPTION KVA AMP AMP KVA CIRCUIT DESCRIPTION Office Lighting 1.2 20 20 1.5 Appliance Recept Office Lighting 1.2 20 20 1.5 Appliance Recept Office Recepts 1.1 20 20 1.5 Appliance Recept Office Recepts 1.1 20 20 1.5 Appliance Recept Office Recepts 1.1 20 20 1.5 Appliance Recept Office Recepts 1.1 20 20 2.0 Hot Water Tank Office Recepts 1.1 20 20 1.8 Existing Empty Space Office Recepts 1.1 20 20 1.8 Existing Empty Space Office Recepts 1.1 20 20 1.8 Existing Empty Space Office Recepts 1.1 20 20 1.8 Existing Empty Space Office Recepts 1.1 20 20 Office Recepts 1.1 20 20 Office Recepts 1.1 20 20 Office Recepts 0.7 20 20 20 20 20 20 Compliance by Building Area 20 20 Total Allowed Watts Total Proposed Watts Interior Lighting Power Allowance Manufacturing facilltv 20 20 5896 COMPLIES Office 20 20 COMPLIES 20 20 20 20 Connected Load: 31.6 kva Demand Load: 32.7 We 88 amp 90.87 amp Connected Load Demand Load 8272 @ 125% 10.34 kva 12.93 kva 18800 @ 125% 18.80 kva 23.50 kva 10000 @ 100% 10.00 kva 10.00 kva 8000 @ 50% 8.00 kva 4.00 kva 14250 @ 100% 14.25 kva 14.25 kva 2000 @ 100% 2.00 kva 2.00 kva 7500 @ 100% 7.50 kva 7.50 kva 7128 @ 125% 7.13 kva 8.91 kva 2376 Manufacturing facility 1st 78.0 kva 83.1 kva Minimum 120/208v 3p service for this installation: Available service capacity: Available Fault Current Calculation Utility Fault Current 26,900 amperes kVA = 150 Area Description Allowed Watts per ft2 E = 208 1 = kVA x 1000 = trans. FLA trans. FLA = 416 E x 1.732 5592 6207 Office Pointto Point Method Support Offices 0.90 I Three Phase 208/120 i 2386 .... Length (distance) FEET L .:......................................._.......................................................................................... _ 40 `Copper in Metal Rac 1.732 x L x I 'f' (ASC) Isca . .._..----..._...._.... = 26,900 factor = N x C x E L -N # conductors per phase N = 3 Phase conductor constant C = 8,925 Phase Conductor 1/0 Volt Line to Line E L - L = Volt Building Area* Location (plan #, room #) f = 0.335 Watts/ Fixture Neutral conductor constant C = 8,925 Neutral Conductor i/o Multiplier Volt Line to Neutral E L - N = 120 Volt ... Office 1st f = 0.870 M= 1 2376 Manufacturing facility 1st 1 + f Line to Line M = 0.749 Manufacturing facility Line to Neutral M = 0.535 Fault Current at Service Equipment 234 Isca x M = fault current at terminals of main disconnect L- L = ► 20,155 amperes Isca x M = fault current at terminals of main disconnect L- N 111 14,384 amperes .................................................................. _......................................................... i Fault Current from IService Equipment to new L2 Panel Copper in Metal Raceway ` Three Phase j Three Phase Feeder Length (distance) L = © hose - 'f' factor = 1.732 x L x I (ASC) Isca = 20,155 Phase 14,384 Neutral N x C x E L -N # conductors per phase N = 1 Phase conductor constant C = 12,844 Phase Conductor ' 3/0 ................... Volt Line to Line E L - L = 208 Volt ............................ f = 0.078 Neutral conductor constant C = 12,844 Neutral Conductor 13/0 ................. Volt Line to Neutral E L - N = 120 Volt Multiplier f = 0.097 M = 1 Line to Line M = 0.927 1 + f Line to Neutral M = 0.912 Isca x M = fault current at terminal of the panel L- L = Isca x M = fault current at terminal of the panel L- N = 18,690 amperes 13,113 amperes 230.8 Amperes @208v 3p 600 Amperes @208v 3p Maximum Allowed Lighting Wattage Building Area* Location (plan #, room #, or ALL) Area Description Allowed Watts per ft2 Gross interior Area in ft2 Watts Allowed (watts/ft2 x area) Manufacturing facilitv 1st Floor Diecut Production 1. 11 5592 6207 Office 1st Floor Support Offices 0.90 2651 2386 U zLU Total 8243 Proposed Lighting Wattage Building Area* Location (plan #, room #) Fixture Description** Number of Fixtures Watts/ Fixture Watts Proposed Manufacturing facility 1st Lightcontrol2T5 47 118 5546 Office 1st 232 Fluorescent 44 54 2376 Manufacturing facility 1st 26w CFL Recessed Can 4 29 116 Manufacturing facility 1st 1T5 Display Valence 3 78 234 Compliance by Building Area Building Area Warnings Total Allowed Watts Total Proposed Watts Interior Lighting Power Allowance Manufacturing facilltv 6207 5896 COMPLIES Office 2386 2376 COMPLIES NEW PANEL L2 200A 120/208V/3PH MLO Total 93 8272 1 NEW - 2" EMT 4-3/0 THHN CU 146 CU -----------------------------------,,.................%........................................................ EXISTING NEW 200A 3P SPACE PANEL L1 150A 120/208V/3PH * ................ MLO = ------------------------------------ SPACE SPACE EX. 150A 3P SPACE EXISTI G 600a 120/208v/3ph Main Lug REVIEWED FOH COMPLIANCE WITH NPPA 70 - NEC APR 2 5 2016 City of TU1(i1a BUILDING DIVIAInKl RECEIVED CITY OF TUKWILA APR 0 8 2016 PERMIT CENTER r0V�tetions op fog . SINCE 1945 a�c10 � o EL,�CTIRIC INC. 0 Zorko Electric, Inc. P.O. Box 100 Duvall, WA 98019 425-788-7710 425,788-7730 fax O O • 0 IZ Q 'S Q J_ I-- w Q IL ry LU O 0 z Q M e wnt t,5 r Uj z LU w_ • U zLU O O • 0 IZ Q 'S Q J_ I-- w Q IL ry LU O 0 z Q M e wnt t,5 r