Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Permit EL16-0325 - RED DOT CORPORATION - NEW SERVICE
RED DOT CORPORATION 495 ANDOVER PARK E EL16-0325 City of Tukwila • Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Inspection Request Line: 206-438-9350 Web site: http://www.TukwilaWA.gov ELECTRICAL PERMIT Parcel No: 2623049094 Permit Number: EL16-0325 Address: 495 ANDOVER PARK E Issue Date: 5/17/2016 WA Cities Electrical Code: 2014 Permit Expires On: 11/13/2016 Project Name: RED DOT CORPORATION 2014 Owner: 2012 WA State Energy Code: Name: HIGHLAND PARK PROPERTIES L 2012 Address: 495 ANDOVER PARK BLVD E, TUKWILA, WA, 98188 Contact Person: Name: COREY MCKINNON Phone: (253) 867-2354 Address: 7056 S 220 ST, KENT, WA, 98032 Contractor: Name: SEA TAC ELECTRIC INC Phone: (253) 872-5553 Address: 7056 S 220TH ST, KENT, WA, 98032- 1910 License No: SEATAE1077RW Expiration Date: 12/17/2017 Lender: Name: Address: DESCRIPTION OF WORK: Remove existing service and provide new 1600A, 480/277V Service. Remove and relocate new electrical system as per plans. Valuation of single family: $0.00 Fees Collected: $2,530.64 Valuation of mf/comm: $125,000.00 Type of Work: TENANT IMP Electrical Service Provided by: PUGET SOUND ENERGY Water District: TUKWILA Sewer District: TUKWILA SEWER SERVICE Current Codes adopted by the City of Tukwila: International Building Code Edition: 2012 National Electrical Code: 2014 International Residential Code Edition: 2012 WA Cities Electrical Code: 2014 International Mechanical Code Edition: 2012 WAC 296-4613: 2014 Uniform Plumbing Code Edition: 2012 WA State Energy Code: 2012 International Fuel Gas Code: 2012 Permit Center Authorized Signature: 1, ) AiC JI— Date: I hearby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this development permit and agree to the conditions attached to this permit. Signature: Date: �;—A-k17 Print Name:_���� This permit shall become null and void if the work is not commenced within 180 days for the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. PERMIT CONDITIONS: <NONE> PERMIT INSPECTIONS REQUIRED Permit Inspection Line: (206) 438-9350 2100 ELECTRICAL FINAL 7003 ROUGH -IN ELECTRICAL 7002 SERVICE 7001 UNDERGROUND/SLAB -M CITY OF TUKWO Community Development Department Permit Center • 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://www.Tukwi]aWA.Roy Electrical Permit No. Project No. _ Date Application Accepted: _ Date Application Expires: ce use ELECTRICAL PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. "Please Print" SITE LOCATION 495 ANDOVER PARK EAST King Co Assessor's Tax No.: Site Address: 495 ANDOVER PARK EAST Suite Number: Floor: Tenant Name: RED DOT CORPORATION New Tenant: ❑ .....Yes ❑✓ ..No PROPERTY OWNER Name: Address: City: State: Zip: CONTACT PERSON — person receiving all project communication Name: COREY MCKINNON Address: 7056 S. 220TH STREET City: KENT State: WA Zip: 98032 Phone: (253) 872-5553 Fax: (253) 872-4112 Email: corey.mckinnon@seatacelectric.com Valuation of Project (contractor's bid price): $ Scope of Work (please provide detailed information): ELECTRICAL CONTRACTOR INFORMATION Company Name: SEA -TAC ELECTRIC, INC. Address: 7056 S. 220TH STREET City: KENT State: WA Zip: 98032 Phone: (253) 867-2354 Fax: (253) 872-4112 Contr Reg No.: SEATAEI077RW Exp Date: 12/01/2015 Tukwila Business License No.: 01-212 PROVIDE AND INSTALL NEW 1600A, 480Y/277V SERVICE IN PLACE OF EXISTING. INCLUDE THE REMOVAL, RELOCATION AND INSTALLATION OF ELECTRICAL SYSTEMS PERTAINING TO THE AFOREMTINOED SCOPE OF WORK. Will service be altered? ❑✓ Yes Type of Use: COMMERCIAL Type of work: ❑ New ❑ Addition ❑ Low Voltage ❑ Generator ❑ No ❑ Service Change ❑ Fire Alarm Property Served by: ® Puget Sound Energy ❑ Seattle City Light H:\Applications\Forms-Applications On Line\2011 ApplicationsTlectrical Permit Application Revised 8-9-1 I.docx Revised: August 2011 bh Adding more than 50 amps? ❑ Remodel ❑ Telecommunication ❑✓ Yes ❑ No ® Tenant Improvement ❑ Temporary Service Page l of 2 RESIDENTIAL NEW RESIDENTIAL SERVICE ❑ New single family dwellings ................................... $152.85 (including an attached garage) ❑ Garages, pools, spas and outbuildings ........................ $81.90 ea ❑ Low voltage systems (alarm, furnace thermostat) ................................ $59.85 ea RESIDENTIAL REMODEL AND SERVICE CHANGES ❑ Service change or alteration ...................................... $81.90 ❑ (no added/altered circuits) $78.75 ❑ Service change with added/altered circuits ................. $81.90 number of added circuits ....................... $11.55 ea ❑ Circuits added/altered without service change ........... $54.60 (up to 5 circuits) $10.50 ea ❑ Circuits added/altered without service change ........... $54.60 (6 or more circuits)...............................................$7.65 ea ❑ Meter/mast repair ....................................................... $68.25 ❑ Low voltage systems ................................................. $59.85 (alarm, furnace thermostat) PERMIT APPLICATION NOTES - MULTI -FAMILY AND COMMERCIAL Fees are based on the valuation of the electrical contract. MISCELLANEOUS FEES ❑ Temporary service (residential) ................................. $63.00 ❑ Temporary service (generator) ................................... $78.75 ❑ Manufactured/mobile home service ........................... $84.00 (excluding garage or outbuilding) ❑ Carnivals.................................................................... $78.75 Number of concessions ......................... $10.50 ea Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation The Building Oficial may grant one extension of time for an additional period not to exceed 90 days. The extension shall be requested in writing and justifiable cause demonstrated. I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. Print Name: COREY MCKINNON Mailing Address: 7056 S. 220TH STREET H:\Applications\Fonm-Applications On Line\2011 Applications\Electrical Permit Application Revised 8-9-1 I.doex Revised: August 2011 bh Date: 4/8/2016 Day Telephone: (253) 872-5553 KENT WA 98032 City State Zip Page 2 of 2 "As". Date Paid: Wednesday, July 20, 2016 Paid By: PETER MOLNER Pay Method: CREDIT CARD 088687 Printed: Wednesday, July 20, 2016 1:19 PM 1 of 1 Date Paid: Wednesday, July 20, 2016 Paid By: SEA TAC ELECTRIC INC Pay Method: CREDIT CARD 048365 Printed: Wednesday, July 20, 2016 1:07 PM 1 of 1 /l SYSTEMS Date Paid: Tuesday, May 17, 2016 Paid By: NICK PROVO Pay Method: CREDIT CARD 026420 Printed: Tuesday, May 17, 2016 8:02 AM 1 of 1 l SYSTEMS DESCRIPTIONS ACCOUNT QUANTITY PAID PermitTRAK $2,043.98 EL16-0325 Address: 495 ANDOVER PARK E Apn: 2623049094 $2,043.98 ELECTRICAL $1,946.65 PERMIT FEE MULTI-FAM/COMM R000.322.101.00.00 0.00 $1,946.65 TECHNOLOGY FEE $97.33 TECHNOLOGY FEE TOTAL FEES PAID$2,043.98 R000.322.900.04.00 0.00 $97.33 Date Paid: Tuesday, April 12, 2016 Paid By: SEATAC ELECTRIC Pay Method: CREDIT CARD 015756 Printed: Tuesday, April 12, 2016 2:40 PM 1 of 1 1 � 1 � � � srsreMs INSPECTION RECORD 2— Retain a copy with permit `N�01 INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 -02 Project:,_ r Type of Inspection: f Address: *P /I Date Called: Special Instructions: Date Wanted: a. p.m. Requester: Phone No: Approved per applicable codes. u Corrections required prior to approval. Iinspector: C IM, W-A/6V,, Iuate: D91(0116 I REINSPECTION IFEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. INSPECTION RECORD 7INO.Z Retain a copy with permitINSPECTION NO. PER CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 D—;+ Inc—+;— Raniiact I Ina tgnal a'4R-Qirin ® Approved per applicable codes. 11 Corrections required prior to approval. Ilnspector: j��.� (�`" Iuaie: OF 106 11 (a I El REINSPECTIdN FEE REQUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. • OFF HOURS INSPECTION • Reimbursement authorization/approval to conduct inspection activities during off hours. Date: 7r20//4,�' Permit Number: C�_/&- 032S Requested By: Firm/Company: �aL�G�t'/rC- R (` IVFD CITY OF TUKWILA Inspection Information Project Name: Re,,6 JUL 2 U 2016 / / C, ,,/ 2 rCl-fml l CENTER Project Address/Location:g7 JS 2YQU� fGt k- C2,12 -'Sl— Requested Date for Inspection: ����/�o Requested Time: 5Q'10 Requested AM / f Contact Name: 6-,* �U1�� Phone Number: ?-��� �5�1` �72 7 Special Conditions for Consideration: ** Contractor will be charged a minimum for three (3) hour inspection time for any off -hours inspection work at $100.00 per hour (minimum total of $300.00). This is to be paid at the time of request. ** The undersigned, as an authorized representative of the above firm, hereby agrees to reimburse the City for its overtime inspections on the above referenced project. A separate invoice will be issued for all inspection time in excess of three (3) hours. Signature: Printed Name: City Use Only: Approved: Disapproved: Date of Approval/Disapproval: Authorized Reviewer: W:\Permit Center\Templates\Forms\off hours inspection 1-2015.docx Revised: January 1, 2015 ZDate: //& el Remarks: Receipt No: C O M M E R C I A L I N 0 U S T R I A L May 2, 2016 To: Jim Benner RE: Project: Red Dot Corporation Address: 495 Andover Park West Tukwila, WA 98188 Permit #: EL16-0325 Dave, Please see my responses below in RED and refer to the updated plans. 1. SCOPE OF WORK ON APPLICATIO INDICATES 1600 AMP BUT ONE LINE SHOWS 2000 AMP. CM (SEI): THE SCOPE OF WORK IS FORA 1600A SERVICE. ANNOTATIONS HAVE BEEN CHANGED ON SHEET E5.01. ALL REVISIONS HAVE BEEN CLOUDED AND ASSIGNED REV DELTA "1". 2. PROVIDE GFPE AT MDS MAIN SWITCH. CM (SE!): GROUND FAULT PROTECTION HAS BEEN ADDED TO THE MAIN DISCONNECT AT MDS ON SHEET E5.01. ALL REVISIONS HAVE BEEN CLOUDED AND ASSIGNED REV DELTA „1„ Please feel free to contact me directly with any questions, comments or concerns. Regards, Corey McKinnon Director of Design, LEED AP BD+C Sea -Tac Electric, Inc. Phone: 253-872-5553 Sma rtPhone: 206-473-2874 Direct : 253-867-2354 Fax: 253-872-4112 Email: corey.m@seatacelectric.com RECEIVED CITY OF TUKWILA MAY 0 2 2016 PERMIT CENTER CORRECTION LT R# �ULe- 632-6 7056 South 220th Street, Kent, WA 98032 1 253.872.5553 City of Tukwila Allan Ekberg, Mayor Department of Community Development Jack Pace, Director April 27, 2016 COREY MCKINNON 7056 S 220 ST KENT, WA 98032 RE: Correction Letter # 1 ELECTRICAL Permit Application Number EL16-0325 RED DOT CORPORATION - 495 ANDOVER PARK EAST Dear COREY MCKINNON, This letter is to inform you of corrections that must be addressed before your development permit can be approved. All correction requests from each department must be addressed at the same time and reflected on your drawings. I have enclosed comments from the following departments: BUILDING - E DEPARTMENT: Jim Benner at 206-431-3679 if you have questions regarding these comments. • CORRECTIONS/ #1 1.) SCOPE OF WORK ON APPLICATION INDICATES 1600 AMP BUT ONE LINE SHOWS 2000 AMP. 2.) PROVIDE GFPE AT MDS MAIN SWITCH. Please address the comments above in an itemized format with applicable revised plans, specifications, and/or other documentation. The City requires that two 2 sets of revised plan pages, specifications and/or other documentation be resubmitted with the appropriate revision block. In order to better expedite your resubmittal, a 'Revision Submittal Sheet' must accompany every resubmittal. I have enclosed one for your convenience. Corrections/revisions must be made in person and will not be accepted through the mail or by a messenger service. If you have any questions, I can be reached at 206-431-3655. Sincerely, C Bill Rambo Permit Technician File No. ELI 6-0325 6300 Southcenter Boulevard Suite #100 e Tukwila Washin.eton 98188 9 Phone 206-431-3670 • Fax 206-431- 3665 PERMIT CBQRD COPY PLAN REVIEW/ROUTING SLIP PERMIT NUMBER: EL16-0325 DATE: 06/27/16 PROJECT NAME: RED DOT CORPORATION SITE ADDRESS: 495 ANDOVER PARK E Original Plan Submittal Response to Correction Letter # Revision # before Permit Issued X Revision # 1 after Permit Issued DEPARTMENTS: (A H to X74 Building DivisionIP Fire Prevention F-1Planning Division ❑ Public Works ❑ Structural ❑ Permit Coordinator ❑ PRELIMINARY REVIEW: DATE: 06/28/16 Not Applicable ❑ Structural Review Required ❑ (no approval/review required) REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: DUE DATE: 07/26/16 Approved gill"- Approved with Conditions ❑ Corrections Required ❑ Denied ❑ (corrections entered in Reviews) (ie: Zoning Issues) Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: 12/18/2013 HERMIT COORD COPY PLAN REVIEW/ROUTING SLIP PERMIT NUMBER: EL16-0325 DATE: 0$10311 PROJECT NAME: RED DOT SITE ADDRESS: 495 ANDOVER PARK E Original Plan Submittal Revision # before Permit Issued X Response to Correction Letter # 1 Revision # after Permit Issued DEPARTMENTS: ��? A -TQ -0 li Building Division Fire Prevention ❑ Planning Division ❑ Public Works ❑ Structural ❑ Permit Coordinator ❑ PRELIMINARY REVIEW: DATE: 05/05/16 Not Applicable ❑ Structural Review Required ❑ (no approval/review required) REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: DUE DATE: 06/02/16 Approved ❑ Approved with Conditions ❑ Corrections Required ❑ Denied ❑ (corrections entered in Reviews) (ie: Zoning Issues) Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: 12/18/2013 eERMIT COORD COPY PLAN REVIEW/ROUTING SLIP PERMIT NUMBER: EL16-0325 DATE: 04/18/16 PROJECT NAME: RED DOT CORPORATION SITE ADDRESS: 495 ANDOVER PARK EAST X Original Plan Submittal Revision # before Permit Issued Response to Correction Letter # Revision # after Permit Issued DEPARTMENTS: 31t> Cgw� - Building Division Fire Prevention ❑ Planning Division ❑ Public Works ❑ Structural ❑ Permit Coordinator ❑ PRELIMINARY REVIEW: DATE: 04/19/16 Not Applicable ❑ Structural Review Required ❑ (no approval review required) REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: DUE DATE: 05/17/16 Approved ❑ Approved with Conditions ❑ Corrections Required Denied ❑ (corrections entered in Reviews) (ie: Zoning Issues) Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only L{ CORRECTION LETTER MAILED: Departments issued corrections: Bldg 20 Fire 0 Ping E] PW E] Staff Initials: V �' �% t 12/18/2013 PROJECT NAME: - DATE RECEIVED CC1r !)1�1�!iV1 PERMIT NO: -PLI C — c�, SITE ADDRESS: q J.Gr ark( ORIGINAL ISSUE DATE: SN -,l —7 -1 Summary of Revision: Ahao +vr lio REVISION NO. DATE RECEIVED STAFF INITIALS ISSUED DATE STAFF INITIALS Summary of Revision: Summary of Revision: Summary of Revision: Ahao +vr Received by REVISION NO. DATE RECEIVED STAFF INITIALS ISSUED DATE STAFF INITIALS Summary of Revision: Summary of Revision: Received by: (please print) REVISION NO. DATE RECEIVED STAFF INITIALS ISSUED DATE STAFF INITIALS Summary of Revision: Summary of Revision: Received by: (please print) REVISION NO. DATE RECEIVED STAFF INITIALS ISSUED DATE STAFF INITIALS Summary of Revision: Summary of Revision: Received by: (please print) REVISION NO. DATE RECEIVED STAFF ISSUED DATE INITIALS STAFF INITIALS STAFF INITIALS Summary of Revision: Received by: (please print) REVISION NO. DATE RECEIVED STAFF INITIALS ISSUED DATE STAFF INITIALS Summary of Revision: Received by: (please print) City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Web site: hqp://www.TukwilaINIA.izov REVISION SUBMITTAL Revision submittals must be submitted in person at the Permit Center. Revisions will not be accepted through the mail, fax, etc. e2-77 �49 Date:_ Plan ChecldPermit Number:—EL /� 6 :i�2 5 ❑ Response to Incomplete Letter # ❑ Response to Correction Letter # Revision # after Permit is Issued ❑ Revision requested by a City Building Inspector or Plans Examiner ❑ Deferred Submittal # Project Name: &W16 0�-- Project Address: L% 5 0�Zb/— Contact Person: R -,e,/ ,- Phone Number:%dC�' �`� moi` Y7Z 9' Summary of Revision: -�v /20CfA- S 6 RECEIVED terry OF TUKWILA Sheet Number(s):01 "Cloud" or highlight all areas of revision including date of revision Received at the City of Tukwila Permit Center by: Nd Entered in TRAKiT on 114M(d W:Termit CenteATemplatesTormsaevision Submittal Form.doc Revised: August 2015 Date: City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Web site: http://www.Tukwi]aWA.gov REVISION SUBMITTAL Revision submittals must be submitted in person at the Permit Center. Revisions will not be accepted through the mail, fax, etc. Plan Check/Permit Number: EL I ( O 3 2--f5 ❑ Response to Incomplete Letter # ❑ Response to Correction Letter # ❑ Revision # after Permit is Issued ❑ Revision requested by a City Building Inspector or Plans Examiner ❑ Deferred Submittal # Project Name: /&,- 60 &,00,z� Project Address: -/1�5 19Y)dOV-P-r -Pccy /L V/z 5q(- TU LIL71 10\ C� & 1 �R8- Contact Person: _OCgL�) Nc 1 RY16V\ Phone Number: 2S 3-5(0-7-2-394/ Summary of Revision: REGEIVEID CITY OF T[ KVYII A. Y�tl RMIT CENT Sheet Number(s): "Cloud" or highlight all areas of revision including date of revilion Received at the Cit of Tukwila Permit Center b6A-e;-Ali City y: ❑ Entered in TRAKiT on I -J W:Termit Center\Templates\Forms\Revision Submittal Formdoc Revised: August 2015 SEA TAC ELECTRIC INC Home FspaiioI CA)ntact Safety & Health inWashington State Department of Labor & Industries SEA TAC ELECTRIC INC Page 1 of 2 Search L&I A -Z Index Help Arty Im Claims & Insurance Workplace Rights Trades & Licensing Owner or tradesperson 7056 S 220TH ST KENT, WA 98032 Principals 253-872-5553 HARGREAVES, TOM, PRESIDENT KING County JORDAN, TOM, VICE PRESIDENT HARGREAVES, KATHERINE, SECRETARY Doing business as SEA TAC ELECTRIC INC WA UBI No. Business type 601 510 212 Corporation Governing persons KATHERINE M HARGREAVES THOMAS R HARGREAVES; TOM JORDAN; License Verify the contractor's active registration / license / certification (depending on trade) and any past violations. Construction Contractor Active. .......................................................................... Meets current requirements. License specialties GENERAL $1,000,000.00 License no. SEATATE970RC Effective — expiration Effective date 12/03/2003-12/15/2017 01/01/2016 Bond ................ Expiration date DEVELOPERS SURETY & INDEM CO $12,000.00 Bond account no. 798648C Received by L&I Effective date 12/03/2008 12/02/2008 Expiration date Until Canceled Insurance ................... _ ... _ .... American Fire & Casualty Co $1,000,000.00 Policy no. BKA56366060 Received by L&I Effective date 12/02/2015 01/01/2016 Expiration date 01/01/2017 Insurance history Savings ........._......... https:Hsecure.Ini.wa.gov/verify/Detail.aspx?UBI=601510212&LIC=SEATATE97ORC&SAW= 5/17/2016 CIRCUITING SYMBOLS POWER SYMBOLS 0 DUPLEX RECEPTACLE 120V 4 DOUBLE DUPLEX RECEPTACLE 120V / DUPLEX / QUAD RECEPTACLE - EMERGENCY POWER DUPLEX RECEPTACLE - GROUND FAULT CIRCUIT INTERRUPTER TYPE DUPLEX RECEPTACLE - GROUND FAULT CIRCUIT INTERRUPTER TYPE, STANDBY POWER DOUBLE DUPLEX RECEPTACLE - GROUND FAULT CIRCUIT INTERRUPTER TYPE DEDICATED DUPLEX / QUAD RECEPTACLE ,NQS DUPLEX RECEPTACLE - SAFETY TYPE VY DUPLEX RECEPTACLE - ABOVE COUNTER: MOUNT +6" ABOVE COUNTER/SINK/ BACKSPLASH OR MOUNT +54" AFF AS APPLICABLE GA DUPLEX RECEPTACLE - ABOVE COUNTER: MOUNT +6" ABOVE COUNTER/SINK/ BACKSPLASH OR MOUNT +5e AFF AS APPLICABLE SPECIAL RECEPTACLE, NEMA/VOLTAGE AS INDICATED ON PLAN - ATTACH TO DROP CORD FROM CEILING SINGLE RECEPTACLE 120V TRIPLE RECEPTACLE SPLIT STITCHED DUPLEX RECEPTACLE FLUSH FLOOR BOX WITH DEVICE AS INDICATED ® FLUSH MOUNTED CEILING RECEPTACLE PEDESTAL TYPE FLOOR BOX WITH DEVICES AS SHOWN 0@& FLUSH FLOOR POKE THROUGH DEVICES AS INDICATED (� SPECIAL RECEPTACLE, NEMA/VOLTAGE AS INDICATED SPECIAL RECEPTACLE, NEMA/VOLTAGE AS INDICATED ® DRYER RECEPTACLE 0' DISCONNECT SWITCH 0 FUSED DISCONNECT ® MOTOR STARTER EP COMBINATION MOTOR STARTER, DISCONNECT MOTOR CONNECTION MOTOR, THREE PHASE G EQUIPMENT CONNECTION & CLOCK HANGER AND OUTLET ON CRITICAL BRANCH CIRCUIT © CONTACTOR M MOTOR RATED SWITCH RA GENERATOR REMOTE ANNUNCIATOR PANEL PANEL - 208/120 VOLT SYSTEM, +6' TO TOP U.N.O. PANEL - 480 VOLT SYSTEM, +6' TO TOP U.N.O. SIGNAL & COMMUNICATION SYMBOLS O NEW WIRING. HASH MARKS INDICATE NUMBER OF #12 AWG WIRE UNLESS NOTED OTHERWISE, NO HASH MARKS INDICATES 10 TWO WIRES PLUS GROUND UNLESS NOTED OTHERWISE. LONG HASH Q MARKS DENOTES NEUTRAL —0— INDICATES GROUND WIRE. T- INDICATES ISOLATED GROUND WIRE, WHERE SHOWN. 1. NEW WIRING RUN IN OR BELOW SLAB OR BELOW GRADE. - - - - - - - EXISTING RACEWAY OR WIRING (IF HASH MARKS ARE SHOWN 1>0 PULL NEW CONDUCTORS) —� RACEWAY STUB -OUT WITH BUSHING ---r► HOME RUN TO PANEL OR LOCATION NOTED T2 CIRCUIT CONTINUATION DOF JUNCTION BOX, CEIUNG/WAH Pe PULL BOX HH HANDHOLE ----Plrlc---- UNDERGROUND UTILITY SERVICE - CIE] POWER, TELEPHONE & CABLE AS INDICATED -i---PAIC OVERHEAD U11UTY SERVICE - W 10. POWER, TELEPHONE & CABLE AS INDICATED (—O POWER POLE/GUY c�-- G GROUND WIRE c'- IRREVERSIBLE COMPRESSION TYPE CONNEC11ON MIN CADWELD TYPE GROUND CONNECTION ® GROUND TEST WELL ® GROUND ROD POWER SYMBOLS 0 DUPLEX RECEPTACLE 120V 4 DOUBLE DUPLEX RECEPTACLE 120V / DUPLEX / QUAD RECEPTACLE - EMERGENCY POWER DUPLEX RECEPTACLE - GROUND FAULT CIRCUIT INTERRUPTER TYPE DUPLEX RECEPTACLE - GROUND FAULT CIRCUIT INTERRUPTER TYPE, STANDBY POWER DOUBLE DUPLEX RECEPTACLE - GROUND FAULT CIRCUIT INTERRUPTER TYPE DEDICATED DUPLEX / QUAD RECEPTACLE ,NQS DUPLEX RECEPTACLE - SAFETY TYPE VY DUPLEX RECEPTACLE - ABOVE COUNTER: MOUNT +6" ABOVE COUNTER/SINK/ BACKSPLASH OR MOUNT +54" AFF AS APPLICABLE GA DUPLEX RECEPTACLE - ABOVE COUNTER: MOUNT +6" ABOVE COUNTER/SINK/ BACKSPLASH OR MOUNT +5e AFF AS APPLICABLE SPECIAL RECEPTACLE, NEMA/VOLTAGE AS INDICATED ON PLAN - ATTACH TO DROP CORD FROM CEILING SINGLE RECEPTACLE 120V TRIPLE RECEPTACLE SPLIT STITCHED DUPLEX RECEPTACLE FLUSH FLOOR BOX WITH DEVICE AS INDICATED ® FLUSH MOUNTED CEILING RECEPTACLE PEDESTAL TYPE FLOOR BOX WITH DEVICES AS SHOWN 0@& FLUSH FLOOR POKE THROUGH DEVICES AS INDICATED (� SPECIAL RECEPTACLE, NEMA/VOLTAGE AS INDICATED SPECIAL RECEPTACLE, NEMA/VOLTAGE AS INDICATED ® DRYER RECEPTACLE 0' DISCONNECT SWITCH 0 FUSED DISCONNECT ® MOTOR STARTER EP COMBINATION MOTOR STARTER, DISCONNECT MOTOR CONNECTION MOTOR, THREE PHASE G EQUIPMENT CONNECTION & CLOCK HANGER AND OUTLET ON CRITICAL BRANCH CIRCUIT © CONTACTOR M MOTOR RATED SWITCH RA GENERATOR REMOTE ANNUNCIATOR PANEL PANEL - 208/120 VOLT SYSTEM, +6' TO TOP U.N.O. PANEL - 480 VOLT SYSTEM, +6' TO TOP U.N.O. SIGNAL & COMMUNICATION SYMBOLS O MAGNETIC DOOR HOLD -OPEN. INTERNAL TO CLOSER HARDWARE WHERE SHOWN AT HINGE. 10 FIRE ALARM MANUAL STATION +48" Q SMOKE DETECTOR Q -i "D" SUBSCRIPT INDICATES DUCT DETECTOR EM "H" SUBSCRIPT INDICATES HEAT DETECTOR 1. "R" SUBSCRIPT INDICATES 120V RESIDENCE DEVICE WITH AUDIBLE 0-0 TONE ALARM, BATTERY BACK-UP 1>0 COMBINATION SPEAKERS/STROBE, WALL MOUNTED AT +80" R UNLESS NOTED OTHERWISE 0 "R" SUBSCRIPT INDICATES AUDIBLE ALARM FOR RESIDENCE UNIT WIRED TO ACCOMODATE UPGRADE TO ALARM/STROBE. DOF COMBINATION HORN/STROBE, CEILING MOUNTED XEI FIRE ALARM STROBE ONLY, WALL MOUNTED AT +80" >O FIRE ALARM STROBE ONLY, CEILING MOUNTED 40 FIRE ALARM REMOTE INDICATOR LIGHT CIE] FIRE ALARM BELL/CHIME FACP FIRE ALARM CONTROL PANEL W 10. TELEPHONE OUTLET: os "W" INDICATES WALL PHONE AT +54" D DATA OUTLET ® COMBINATION TELE/DATA OUTLET Q COMBINATION FIRE/SMOKE DAMPER CONNECTION 0 MOTORIZED DAMPER - 120V ® M MC MAGNETIC CONTACTS FOR WINDOW OR DOOR MONITORING -i PEDESTAL TYPE FLOOR BOX WITH DEVICE TYPE AS SHOWN —o—o- CABLE RING ROUTE & ELECTRIC CLOCK ED TV COAXIAL CONNECTION OO CEILING MOUNTED SPEAKER O WALL MOUNTED SPEAKER D MICROPHONE OTR TELEPHONE RISER ® FLOOR CORE FOR VOICE/DATA ONLY FUR1 CARD READER Est AUDIBLE DOOR ALARM 01 VOLUME CONTROL AT +54" C-+ EMERGENCY POWER OFF BUTTON S N 0 s W 0 0 0 W 0 z 0 W CL i U W 'o Ix w LIGHTING SYMBOLS xx EM FLUORESCENT FIXTURE, TYPE AS INDICATED ON PLAN "XX" INDICATES FIXTURE TYPE, "EM" INDICATES EMERGENCY OPERATION P ----- 4 FLUORESCENT STRIP FIXTURE, DRAWN TO SCALE Q FIXTURE CEILING MOUNTED Q -i FIXTURE WALL MOUNTED EM FULL -SHADED FIXTURES SHALL BE CONNECTED TO EMERGENCY POWER 'EM" 1. SERVICE PANEL, INDICATES EMERGENCY OPERATION 0-0 POLE MOUNTED EXTERIOR LIGHT FIXTURE XXM BATTERY PACK EMERGENCY UGHTING UNIT ® BATTERY POWERED EXIT SIGN - ARROWS AS INDICATED, SHADING 0 INDICATES SIDE(S) ILLUMINATED. BATTERY POWERED EXIT SIGN WITH INTEGRAL EMERGENCY LIGHTS, CL ARROWS AS INDICATED X x SINGLE POLE SWITCH (LETTER INDICATES SWITCH LEG) fs OCCUPANCY SENSOR WALL SWITCH 3 3 WAY SWITCH 0 INCANDESCENT DIMMER/SWITCH , FLUORESCENT DIMMER/SWITCH DAYLIGHT SENSOR, # INDICATES CONTROLLED CIRCUIT DESIGNATION os CEILING OCCUPANCY SENSOR Pc PHOTO -CELL SWITCH MOUNTED UNDER SOFFIT, ORIENT NORTH ro TTMECLOCK ` { FIXTURE PENDANT MOUNTED In WALL SCONCE • SURFACE MOUNT 2X4 -i TRACK LIGHTING RISER SYMBOLS TRANSFER SWITCH -- CIRCUIT BREAKER DRAW OUT CIRCUIT BREAKER OFEEDER DESIGNATION -off- FUSED SWITCH GROUND PM& PANEL G GROUND FAULT CIRCUIT BREAKER TRANSFORMER CABLE TO BUS CONNEC11ON AVAILABLE SHORT CIRCUIT CURRENT ® METER ABBREVIATIONS NOTE REGARDING DRAWINGS: THESE DRAWINGS ARE PROVIDED FOR YOUR USE RELATING EXCLUSIVELY TO THE PROJECT CONTAINED HEREIN. SEA -TAC ELECTRIC, INC. PROVIDES THESE DRAWINGS WITH THE FOLLOWING STIPULATIONS: THIS DOCUMENT, AND THE IDEAS AND DESIGNS INCORPORATED HEREIN, AS AN INSTRUMENT OF PROFESSIONAL SERVICE, IS THE PROPERTY OF SEA -TAC ELECTRIC, INC. AND IS NOT TO BE USED, IN WIOLE OR IN PART, FOR ANY OTHER PROJECT WITHOUT THE WRITTEN CONSENT OF SEA -TAC ELECTRIC, INC. THE DESIGNS CONTAINED HEREIN ARE PROTECTED BY THE RULES AND REGULATIONS OF U.S. COPYRIGHT LAWS. THESE DRAWINGS AND DOCUMENTS WERE COPIED FROM COMPUTER DATA CREATED AS A STEP IN THE PRODUCTION OF PHYSICAL DATA FOR THIS PROJECT. THERE MAY BE DISCREPANCIES BETWEEN THESE DOCUMENTS AND THE COMPUTER DATA. WHERE SUCH DISCREPANCIES EXIST, ONLY THE PHYSICAL DOCUMENTS AND DRAWINGS CAN BE RELIED ON TO REFLECT THE WORK OF SEA -TAC ELECTRIC, INC., WHO MAKES NO GUARANTEES OR WARRANTIES REGARDING THESE DOCUMENTS OR THE DATA THEREIN. IN ACCEPTING THESE DOCUMENTS, YOU ASSUME ALL LIABILITY FOR THE ACCURACY, UTILITY, OR SUITABILITY FOR ANY PURPOSE FOR ANY DATA THESE DRAWINGS CONTAIN. COPYRIGHT© 2015 GENERAL NOTES: NOTE: 'CONTRACTOR' MEANS "ELECTRICAL CONTRACTOR" WHEN REFERENCED ANYWHERE IN THE ELECTRICAL CONSTRUCTION DOCUMENTS UNLESS WORK AND EQUIPMENT HAS BEEN COORDINATED BETWEEN THE ELECTRICAL AND GENERAL CONTRACTORS TO BE PROVIDED BY THE GENERAL CONTRACTOR. "NEEDED", "PROMIDE", AND "INSTALL" MEANS ALL ITEMS CALLED OUT IN THE CONTRACT DOCUMENTS AND ANY ADDITIONAL ITEMS NOT CALLED OUT BUT REQUIRED TO MAKE A COMPLETE AND OPERATIONAL SYSTEM. SCOPE: THE INTENT OF THE DRAWINGS IS TO PROVIDE A COMPLETE AND FULLY OPERATIONAL ELECTRICAL SYSTEM. THE ELECTRICAL CONTRACTOR SHALL FURNISH AND INSTALL ALL LABOR, MATERIAL AND EQUIPMENT NECESSARY TO COMPLETE THE ELECTRICAL WORK. PERMITS AND FEES: THE ELECTRICAL CONTRACTOR SHALL PROCURE AND PAY FOR ALL PERMITS, FEES AND INSPEC11ONS NECESSARY TO COMPLETE THE ELECTRICAL SCOPE OF WORK PRIOR TO STARTING THE WORK. WARRANTY: THE ELECTRICAL CONTRACTOR SHALL UNCONDITIONALLY WARRANTY ALL WORK TO BE FREE OF DEFECTS IN MATERIAL AND WORKMANSHIP FOR A PERIOD OF ONE (1) YEAR FROM THE DATE OF FINAL ACCEPTANCE BY THE OWNER OR OWNER'S REPRESENTATIVE AND WILL REPAIR OR REPLACE ANY DEFECTIVE WORK PROMPTLY AND WITHOUT CHARGE AND RESTORE ANY OTHER EXISTING WORK DAMAGED IN THE COURSE OF REPAIRING DEFECTIVE MATERIALS AND WORKMANSHIP. PPERFO ALL WORK IN ACCORDANCE WITH THE CURRENT NA11ONAL ELECTRICAL CODE, STATES, CITY ELECTRICAL CODES, AND ALL OTHER APPLICABLE CODES INCLUDING ANY STATE OR LOCAL ENERGY CODES. ALL WORK SHALL ALSO BE IN COMPLIANCE WITH BUILDING OWNER'S CRITERIA. IN CASE OF CONFLICT BETWEEN THE DRAWINGS, SPECIFICATIONS, CODES, ORDINANCES, AND AUTHORITIES HAVING JURISDICTION, THE MOST STRINGENT STANDARD (IN THE OPINION OF THE ENGINEER) SHALL APPLY. THE EC SHALL SATISY CODE, AHJ, DRAWINGS, AND SPECIFICATIONS AS A MININUM STANDARD WITHOUT ANY EXTRA COST. STANDARDS: EQUIPMENT AND MATERIALS SHALL CONFORM WITH APPROPRIATE PROVISIONS OF NEC, WAC, ASTM, UL, ETL, NEMA, ANSI, AND OTHER APPLICABLE AGENCY AS THEY APPLY TO EACH INDIVIDUAL UNIT OR ASSEMBLY. COPYRIGHT© 2015' MISCELLANEOUS FLAG NOTE Q REVISION SYMBOL -' EXISTING EQUIPMENT OR DEVICE XXX REMOVE EXISTING ELECTRICAL EQUIPMENT xx-x EQUIPMENT IDENTIFIER 1. TYPICAL ROOM DETAIL REFERENCES: XX - INDICATES DETAIL NUMBER XXM M - INDICATES THAT DETAIL IS MIRROR IMAGE OF REFERENCED LOCATION E}(.Y EY.Y - INDICATES SHEET WHERE DETAIL IS FOUND 0 - DIRECTION OF ARROW INDICATES PLAN ORIENTATION IN RELATION TO DETAIL CL PROPERTY LINE X x FENCING ® CABLE TRAY Q INDICATES COMBINATION POWER/TELE/DATA POKE-THRU FLUSH 0 FURNITURE FEED JUNTION BOX. ABBREVIATIONS NOTE REGARDING DRAWINGS: THESE DRAWINGS ARE PROVIDED FOR YOUR USE RELATING EXCLUSIVELY TO THE PROJECT CONTAINED HEREIN. SEA -TAC ELECTRIC, INC. PROVIDES THESE DRAWINGS WITH THE FOLLOWING STIPULATIONS: THIS DOCUMENT, AND THE IDEAS AND DESIGNS INCORPORATED HEREIN, AS AN INSTRUMENT OF PROFESSIONAL SERVICE, IS THE PROPERTY OF SEA -TAC ELECTRIC, INC. AND IS NOT TO BE USED, IN WIOLE OR IN PART, FOR ANY OTHER PROJECT WITHOUT THE WRITTEN CONSENT OF SEA -TAC ELECTRIC, INC. THE DESIGNS CONTAINED HEREIN ARE PROTECTED BY THE RULES AND REGULATIONS OF U.S. COPYRIGHT LAWS. THESE DRAWINGS AND DOCUMENTS WERE COPIED FROM COMPUTER DATA CREATED AS A STEP IN THE PRODUCTION OF PHYSICAL DATA FOR THIS PROJECT. THERE MAY BE DISCREPANCIES BETWEEN THESE DOCUMENTS AND THE COMPUTER DATA. WHERE SUCH DISCREPANCIES EXIST, ONLY THE PHYSICAL DOCUMENTS AND DRAWINGS CAN BE RELIED ON TO REFLECT THE WORK OF SEA -TAC ELECTRIC, INC., WHO MAKES NO GUARANTEES OR WARRANTIES REGARDING THESE DOCUMENTS OR THE DATA THEREIN. IN ACCEPTING THESE DOCUMENTS, YOU ASSUME ALL LIABILITY FOR THE ACCURACY, UTILITY, OR SUITABILITY FOR ANY PURPOSE FOR ANY DATA THESE DRAWINGS CONTAIN. COPYRIGHT© 2015 GENERAL NOTES: NOTE: 'CONTRACTOR' MEANS "ELECTRICAL CONTRACTOR" WHEN REFERENCED ANYWHERE IN THE ELECTRICAL CONSTRUCTION DOCUMENTS UNLESS WORK AND EQUIPMENT HAS BEEN COORDINATED BETWEEN THE ELECTRICAL AND GENERAL CONTRACTORS TO BE PROVIDED BY THE GENERAL CONTRACTOR. "NEEDED", "PROMIDE", AND "INSTALL" MEANS ALL ITEMS CALLED OUT IN THE CONTRACT DOCUMENTS AND ANY ADDITIONAL ITEMS NOT CALLED OUT BUT REQUIRED TO MAKE A COMPLETE AND OPERATIONAL SYSTEM. SCOPE: THE INTENT OF THE DRAWINGS IS TO PROVIDE A COMPLETE AND FULLY OPERATIONAL ELECTRICAL SYSTEM. THE ELECTRICAL CONTRACTOR SHALL FURNISH AND INSTALL ALL LABOR, MATERIAL AND EQUIPMENT NECESSARY TO COMPLETE THE ELECTRICAL WORK. PERMITS AND FEES: THE ELECTRICAL CONTRACTOR SHALL PROCURE AND PAY FOR ALL PERMITS, FEES AND INSPEC11ONS NECESSARY TO COMPLETE THE ELECTRICAL SCOPE OF WORK PRIOR TO STARTING THE WORK. WARRANTY: THE ELECTRICAL CONTRACTOR SHALL UNCONDITIONALLY WARRANTY ALL WORK TO BE FREE OF DEFECTS IN MATERIAL AND WORKMANSHIP FOR A PERIOD OF ONE (1) YEAR FROM THE DATE OF FINAL ACCEPTANCE BY THE OWNER OR OWNER'S REPRESENTATIVE AND WILL REPAIR OR REPLACE ANY DEFECTIVE WORK PROMPTLY AND WITHOUT CHARGE AND RESTORE ANY OTHER EXISTING WORK DAMAGED IN THE COURSE OF REPAIRING DEFECTIVE MATERIALS AND WORKMANSHIP. PPERFO ALL WORK IN ACCORDANCE WITH THE CURRENT NA11ONAL ELECTRICAL CODE, STATES, CITY ELECTRICAL CODES, AND ALL OTHER APPLICABLE CODES INCLUDING ANY STATE OR LOCAL ENERGY CODES. ALL WORK SHALL ALSO BE IN COMPLIANCE WITH BUILDING OWNER'S CRITERIA. IN CASE OF CONFLICT BETWEEN THE DRAWINGS, SPECIFICATIONS, CODES, ORDINANCES, AND AUTHORITIES HAVING JURISDICTION, THE MOST STRINGENT STANDARD (IN THE OPINION OF THE ENGINEER) SHALL APPLY. THE EC SHALL SATISY CODE, AHJ, DRAWINGS, AND SPECIFICATIONS AS A MININUM STANDARD WITHOUT ANY EXTRA COST. STANDARDS: EQUIPMENT AND MATERIALS SHALL CONFORM WITH APPROPRIATE PROVISIONS OF NEC, WAC, ASTM, UL, ETL, NEMA, ANSI, AND OTHER APPLICABLE AGENCY AS THEY APPLY TO EACH INDIVIDUAL UNIT OR ASSEMBLY. COPYRIGHT© 2015' AC INDICATES ABOVE COUNTER MOUNTING .,.£ AT +4" ABOVE BACKSPLASH OR +6" ABOVE COUNTERS WITHOUT BACKSPLASH AFF ABOVE FINISHED FLOOR A, AMP AMPERE Flan I•a-Mew aoval is subjed to errors and omissions. ATS AUTOMATIC TRANSFER SWITCH Approval of Construdtion documents does not az.►►Wza AWG AMERICAN WIRE GAGE the Violation of any adopted coda mr ordinance. Reconipt (BTS) BASE TRANSFER STATION of approved Field Copy and condiuons is acknoMedged: CB CIRCUIT BREAKER BY: CKT CIRCUIT Date:, /�% 1,�__,.,,,,,. REVIFEWED FOR � DED DEDICATED COMPLIANCE WET DW DISHWASHER City of Tukwila� (E) EXISTING BUILDING D1VISt JUL 01 .16 EPO EMERGENCY POWER OFF EWC ELECTRIC WATER COOLER FA FIRE ALARM Dlty ®f TU Ila BUILDING DIVISION FBOIC FURNISHED BY OTHERS, INSTALLED BY CONTRACTOR FI FILM ILLUMINATOR G, GND GROUND GD GARBAGE DISPOSAL GFl, GFCI GROUND FAULT CIRCUIT INTERRUPTER HT HEIGHT REVISIONS HWT HOT WATER TANK No o ane k Asthal be apP the scope roval of IGN IGN111ON TuM', itla Building Diivision. NOTE: Re. isien will require a new plan submittal ' # IH INSTA HOT and may include additional plan review fees_ REV DATE J -BOX JUNCTION BOX � 05/02/2016 - MW MICROWAVE - COORDINATE MOUNTING HEIGHT Q2 06/03/2016 N NEUTRAL P POLE PNL PANEL PROVIDE FURNISH AND INSTALL (R) RELOCATED (INDICATES EXISTING EQUIPMENT TO BE RE -INSTALLED AS SHOWN) RO RACEWAY ONLY REC RECEPTACLE REF REFRIGERATOR r, R WM C t4TeR S SAFETY TYPE �� DRAWN CM SWBD SWITCHBOARD E CHECKED CM TYP TYPICAL � 1 ISION N0 DATE 06/06/2016 UC UNDERCABINET UNO UNLESS NOTED OTHERWISE SYMBOLS & V VOLT ABBREVIATIONS W WIRE OR WATT DRAWING INDEX PHASE EO.01 - SYMBOLS & ABBREVIATIONS W/0 WITHOUT E0.02 - ELECTRICAL NOTES Mh WP WEATHERPROOF E2.01 NORTH POWER PLAN E5.01 - ONE -LINE RISER DIAGRAM E 0 no 0 1. 0 U) .• 0 z .• CL VVI .• j CL • , • • • LO 0. AC INDICATES ABOVE COUNTER MOUNTING .,.£ AT +4" ABOVE BACKSPLASH OR +6" ABOVE COUNTERS WITHOUT BACKSPLASH AFF ABOVE FINISHED FLOOR A, AMP AMPERE Flan I•a-Mew aoval is subjed to errors and omissions. ATS AUTOMATIC TRANSFER SWITCH Approval of Construdtion documents does not az.►►Wza AWG AMERICAN WIRE GAGE the Violation of any adopted coda mr ordinance. Reconipt (BTS) BASE TRANSFER STATION of approved Field Copy and condiuons is acknoMedged: CB CIRCUIT BREAKER BY: CKT CIRCUIT Date:, /�% 1,�__,.,,,,,. REVIFEWED FOR � DED DEDICATED COMPLIANCE WET DW DISHWASHER City of Tukwila� (E) EXISTING BUILDING D1VISt JUL 01 .16 EPO EMERGENCY POWER OFF EWC ELECTRIC WATER COOLER FA FIRE ALARM Dlty ®f TU Ila BUILDING DIVISION FBOIC FURNISHED BY OTHERS, INSTALLED BY CONTRACTOR FI FILM ILLUMINATOR G, GND GROUND GD GARBAGE DISPOSAL GFl, GFCI GROUND FAULT CIRCUIT INTERRUPTER HT HEIGHT REVISIONS HWT HOT WATER TANK No o ane k Asthal be apP the scope roval of IGN IGN111ON TuM', itla Building Diivision. NOTE: Re. isien will require a new plan submittal ' # IH INSTA HOT and may include additional plan review fees_ REV DATE J -BOX JUNCTION BOX � 05/02/2016 - MW MICROWAVE - COORDINATE MOUNTING HEIGHT Q2 06/03/2016 N NEUTRAL P POLE PNL PANEL PROVIDE FURNISH AND INSTALL (R) RELOCATED (INDICATES EXISTING EQUIPMENT TO BE RE -INSTALLED AS SHOWN) RO RACEWAY ONLY REC RECEPTACLE REF REFRIGERATOR r, R WM C t4TeR S SAFETY TYPE �� DRAWN CM SWBD SWITCHBOARD E CHECKED CM TYP TYPICAL � 1 ISION N0 DATE 06/06/2016 UC UNDERCABINET UNO UNLESS NOTED OTHERWISE SYMBOLS & V VOLT ABBREVIATIONS W WIRE OR WATT DRAWING INDEX PHASE EO.01 - SYMBOLS & ABBREVIATIONS W/0 WITHOUT E0.02 - ELECTRICAL NOTES Mh WP WEATHERPROOF E2.01 NORTH POWER PLAN E5.01 - ONE -LINE RISER DIAGRAM E 0 no 1. FEEDERS ARE ALUMINUM NTH THHN/THWN INSULATION. 2. PROVIDE PULL BOXES AS REQUIRED BY THE NEC. 3. SHORT CIRCUIT CURRENTS LESS THAN 10,000 AIC FOR 208V PANELS AND 14,000 AIC FOR 480V PANELS ARE NOT SHOWN. 4. THE ONE -LINE DIAGRAM IS DIAGRAMMATIC AND DOES NOT SHOW THE ACTUAL ROUTING OF RACEWAYS. 5. FOR TWO SEC11ON PANELS PROVIDE FULL SIZE FEEDER CONNECTIONS FROM SECTION 1 TO SECTION 2. 6. NOT ALL CIRCUIT BREAKERS ARE SHOWN, REFER TO PANEL AND S"TCHBOARD SCHEDULES FOR OTHER LOADS SERVED, AND SPARE CIRCUIT BREAKERS. BRANCH CIRCUIT WIRING. 1. IN GENERAL ONLY CIRCUIT NUMBERS HAVE BEEN SHOWN ON THE DRAWNGS. THE CONTRACTOR SHALL PROVIDE ALL REQUIRED RACEWAYS AND WRING. 2. SHOW RACEWAYS AND WRING ON AS -BUILT DRAWNGS. 3. GENERAL: - 3.1. MINIMUM RACEWAY SIZE SHALL BE r EMT 3.2. NO MORE THAN 6 #12 AWG CONDUCTORS SHALL BE INSTALLED IN A RACEWAY, 3.3. HOMERUNS GREATER THAN 100 FEET TO THE FIRST DEVICE SHALL BE #10 AWG. 3.4. LIGHTING, POWER AND MECHANICAL EQUIPMENT CONDUCTORS SHALL NOT BE COMBINED IN THE SAME RACEWAY. 3.5. PROVIDE A GROUND CONDUCTOR IN ALL RACEWAYS. 3.6. PROVIDE A DEDICATED NEUTRAL CONDUCTOR FOR EACH BRANCH CIRCUIT. BREAKER TIES OR MUL11-POLE BREAKERS MAY BE USED IN LIEU OF A DEDICATED NEUTRAL 4. LIGHTING - 4.1. PROVIDE CONDUCTORS AS REQUIRED TO PROVIDE CIRCUITING AND SWTCHING DUTY AS SHOWN ON THE DRAWNGS. 4.2. PROVIDE A DEDICATED NEUTRAL CONDUCTOR FOR EACH BRANCH CIRCUIT. BREAKER TIES OR MULTI -POLE BREAKERS MAY BE USED IN LIEU OF A DEDICATED NEUTRAL 5. POWER: 5.1. PROVIDE CONDUCTORS AS REQUIRED TO PROVIDE CIRCUITING SHOWN. 5.2. FOR OTHER THAN 15 OR 20 AMP SINGLE PHASE RECEPTACLE BRANCH CIRCUITS PROVIDE A DEDICATED HOMERUN TO THE PANEL 5.3. FOR 30 AMP BRANCH CIRCUITS PROVIDE #10 AWG CONDUCTORS. FOR 40 AMP AND LARGER BRANCH CIRCUITS PROVIDE RACEWAYS AND WRING AS SHOWN ON THE DRAWNGS. 5.4. PROVIDE A DEDICATED NEUTRAL CONDUCTOR FOR EACH BRANCH CIRCUIT. BREAKER TIES OR MULT1-POLE BREAKERS MAY BE USED IN LIEU OF A DEDICATED NEUTRAL 6. MECHANICAL EQUIPMENT. PROVIDE RACEWAYS AND WRING AS SHOWN ON THE MECHANICAL EQUIPMENT CONNECTION SCHEDULE. 8 04 Z C3 CL cr RACEWAYS PROVIDE CODE APPROVED WRING METHODS FOR BRANCH CIRCUITING INDOORS, SUCH AS EMT CONDUIT WITH COPPER CONDUCTORS OR MC CABLE (PROVIDED IT IS CONCEALED FROM MEW AND NOT EXPOSED). ALL ABOVE GROUND CONDUITS SHALL BE EMT OR RIGID, MINIMUM 1/2- IN SIZE (LION). CONDUITS SHALL BE SIZED PER CODE AND AS NEEDED TO INSTALL CONDUCTORS. CONDUIT CONNECTORS SHALL BE DOUBLE LOCKNUT TYPE, UL LISTED AND LABELED, WTH COMPRESSION OR SET SCREW FITTINGS. PVC CONDUITS ARE NOT ALLOWED ABOVE SLAB UNLESS CODE AND AHJ APPROVED/LISTED FOR THAT USE. CONDUIT RUNS ON EXTERIOR OF BUILDING SHALL BE CONCEALED AND BE RIGID STEEL CONDUIT WTH WEATHER TIGHT, CORRISION-RESISTANT FITTINGS (OR PVC wHERE LISTED FOR EXTERIOR -SUNLIGHT USE). CONDUIT SHALL NOT BE RUN EXPOSED WTHOUT SPECIFIC PERMISSION FROM THE CONSTRUCTION MANAGER. WHERE RACEWAYS ARE INSTALLED FOR OTHERS TO USE, OR FOR FUTURE USE, PROVIDE NYLON PULL STRINGS END TO END NTH A LABEL ON BOTH ENDS STATING USE AND LOCATION OF OTHER STUB (E.G. DATA -FRONT POS). PENETRATIONS THROUGH FIRE RATED CONSTRUCTION SHALL BE SEALED USING 3M FIRE BARRIER CAULK, NELSON ELECTRIC FLAMESEAL OR T&B FLAME SAFE OR OTHER METHOD APPROVED THE ARCHITECT AND AHJ. CONDUIT RUNS CONCEALED IN CONCRETE OR UNDERGROUND SHALL BE 3/4- MINIMUM, UNLESS OTHERMSE NOTED W/RIGID STEEL ELBOWS. CONDUIT CONNECTORS SHALL BE DOUBLE LOCKNUT TYPE, UL LISTED AND LABELED, NTH COMPRESSION OR SET SCREW FITTINGS. IF CONDUIT RACEWAYS CANNOT BE RECESSED IN WALLS DUE TO CONSTRUCTION OR EXISTING CONDITIONS, PROVIDE A STEEL SURFACE MOUNTED RACEWAY SYSTEM (VAREMOLD, HUBBEL OR APPROVED EQUAL) NTH ALL COMPATIBLE DEVICES. THIS TYPE OF SYSTEM IS ONLY ALLOWED WfHERE APPROVED BY OWNER OR OWNER'S REPRESENTATIVE INCLUDING LAYOUT. CONFIRM COLOR AND ANY CUSTOM FINISHES NTH OWNER OR OWNER'S REPRESENTATIVE. CONDUCTORS AND TERMINATIONS CONDUCTORS: SHALL BE ALUMINUM, INSULATED FOR 60OV, TYPE THWN/THHN, NUMBER 12 AWG MIMIMUM UNO. MOTORS AND OTHER WRING: THE ELECTRICAL CONTRACTOR SHALL PROVIDE ALL NEEDED CONDUIT, WRING, CONNECTIONS, AND SAFETY SWTCHES FOR ALL MOTORS, AND EQUIPMENT, EVEN IF THE MOTORS AND EQUIPMENT ARE SUPPLIED BY OTHERS. MOTORS, CONTROLS, ETC. MAY BE FURNISHED BY THE SUPPLIER OF THE DRIVEN EQUIPMENT. THE ELECTRICAL CONTRACTOR SHALL INCLUDE ALL WORK AND CONNECTIONS NEEDED TO MAKE THE SYSTEM COMPLETE AND OPERA11ONAL ALL ELECTRICAL CONNECTIONS TO MECHANICAL EQUIPMENT SHALL BE DONE BY THE ELECTRICAL CONTRACTOR. THE ELECTRICAL CONTRACTOR SHALL VERIFY EQUIPMENT LOCATION AND SIZES WTH THE TRADE AND VENDOR SUPPLYING THE EQUIPMENT PRIOR TO ROUGH -IN. GROUNDING ALL MAJOR PARTS NOT CARRYING CURRENT, INCLUDING BUT NOT LIMITED TO, SECONDARY FEEDER CIRCUIT, EQUIPMENT AND PANELBOARD ENCLOSURES, PULL AND JUNCTION BOXES AND OTHERS DEFINED BY CODE, SHALL BE PROPERLY GROUNDED. METALLIC RACEWAYS SHALL UTILIZE DOUBLE LOCKNUTS AND OTHER FITTINGS TO PROVIDE GROUND CONTINUITY. SWITCHES AND RECEPTACLES SWTCHES: GRADE OR APPROVED EQUAL WTH DURABLE COVERPLATES. COORDINATE WTH OWNER OR OWNER'S REPRESENTATIVE DM FOR COVERPLATE TYPE (E.G. STAINLESS STEEL) AND FOR COLOR OF SWTCH AND PLATE. RECEPTACLES: GRADE OR APPROVED EQUAL WTH DURABLE COVERPLATES. COORDINATE WTH OWNER OR OWNER'S REPRESENTATIVE DM FOR FOR COVERPLATE TYPE (E.G. STAINIESS STEEL) AND FOR COLOR OF RECEPTACLE AND PLATE. INSTALL RECEPTACLES PLUMB, LEVEL, AND SECURE TO J -BOX PROVIDE GFCI TYPE MERE INDICATED AND VMERE REQUIRED BY CODE AND AHJ. GFCI RECEPTACLES SHALL BE CLASS A RATED FOR PERSONNEL PROTECTION.ALL RECEPTACLES ARE TO BE MOUNTED 18" ABOVE FINISHED FLOOR TO CENTER OF DEVICE UNLESS NOTED OTHERVASE. OCCUPANCY SENSORS: SENSORSWTCH WSD SERIES FOR SINGLE OCCUPANT RESTROOMS AND CLOSETS AND SENSORSWTCH CONTRACTOR CHOSEN/OWNER APPROVED (PIR AND ULTRASONIC SOUND ACTIVATED) FOR PARTITIONED RESTROOMS. LOW VOLTAGE ALL LOW VOLTAGE WORK SHALL COMPLY, BE PERMITTED AND INSPECTED PER STATE (AND LAHJ) REQUIREMENTS. ALL LOW VOLTAGE WORK SHALL BE INSTALLED BY A LICENSED CONTRACTOR IN ACCORDANCE NTH THE STATE AND LAHJ REQUIREMENTS. ALL LOW VOLTAGE CABLING INSTALLED UNDERGROUND SHALL BE ROUTED IN A CONDUIT RACEWAY AND CABLING/CONDUCTORS SHALL BE LISTED FOR USE IN WET LOCATIONS, FOR LOW VOLTAGE APPLICATION AND PER LAHJ. ALL LOW VOLTAGE CABLING ROUTED INDOORS SHALL BE ROUTED CONCEALED IN WALLS/CEILINGS IN A CONDUIT RACEWAY (UNLESS OWNER AND LAHJ AUTHORIZE IT TO BE ROUTED EXPOSED THROUGH WALL/CEILING). IF APPROVED BY OWNER & LAHJ TO BE ROUTED EXPOSED, CABLING SHALL BE PROPERLY FASTENED/SUPPORTED PER CODE, LAHJ, AND INDUSTRY STANDARDS. CABLING NOT ROUTED IN CONDUIT SHALL BE PLENUM RATED WfHERE REQUIRED BY CODE OR LAHJ (CONFIRM WHETHER CEILING SPACE IS BEING USED AS AN AIR PLENUM.) ALL LOW VOLTAGE CABLING OUTDOORS (E.G. ON ROOF) SHALL BE ROUTED IN CONDUIT PER CODE AND LAHJ REQUIREMENTS UNLESS SPECIFICALLY LISTED AND LABELED FOR EXTERIOR USE. PANELBOARDS PANELBOARDS SHALL HAVE PLUG-IN OR BOLT ON BREAKERS AND MAIN LUGS ONLY OR MAIN BREAKERS AS NEEDED OR REQUIRED. PANELBOARDS SHALL BE CONSTRUCTED NTH ALUMINUM BUS AND BE ENCLOSED IN NEMA 1 HOUSING (OR AS REQD BY CODE). ENCLOSURE(S) SHALL BE COMPLETE NTH A HINGED DOOR, CYLINDER LOCK, AND A NEATLY TYPED CIRCUIT BREAKER DIRECTORY UNDER PLASTIC COVER IN EACH PANEL ALL MULTIPLE POLE BREAKERS (AND OTHER BREAKERS REVD BY CODE) SHALL HAVE A COMMON TRIP HANDLE. FUSED SWITCHES FUSED SWTCHES: HEAVY DUTY TYPE, HORSE POWER RATED NTH INTERLOCKING COVER. NEMA 1 TYPICAL OUTDOORS AND WET LOCATION SNTCHES SHALL BE RAINTIGHT TYPE NEMA 3R. ALL SWTCHES SHALL BE LOCKABLE. FUSES IN CIRCUITS RATED AT 600A OR LESS SHALL BE UL CLASS RKII DUAL -ELEMENT, TIME DELAY, CURRENT LIMITING FUSES. FUSES IN CIRCUITS RATED AT 601A OR LARGER SHALL BE UL CLASS L TIME -DELAY, CURRENT LIMITING SWTCHES. MOUNTING-.'. MOUNT DISCONNECTS TO STRUCTURE, INDEPENDENT OF THE MECHANICAL UNIT HOUSING OR WTH INDEPENDENT UNISTRUT SUPPORT. DISCONNECTS MOUNTED TO UNITS ARE ONLY ALLOWED WlIERE ACCEPTED BY THE LOCAL CODE AUTHORITY AND LOCATED SO AS TO NOT BLOCK ACCESS OR LABELS OF UNIT. NAMEPLATES PROVIDE PHENOLIC NAMEPLATES ON ELECTRICAL DEVICES SUCH AS DISCONNECTS AND PANELS NTH THEIR DESIGNATION (E.G. "PANEL A*). PROVIDE DIRECTORY FOR PANELS AND LABEL ALL BREAKERS. IF A TRANSFORMER IS INSTALLED, PROVIDE NAMEPLATE ON TRANSFORMER AS FOLLOWS: "HOT SURFACE, DO NOT PLACE ANY ITEMS ON TOP OR ON SIDES OF TRANSFORMER". uj r 100A PAS p,FcFj\jEo cl-fy OF Tuyv4jL_A T C;FN.TER 0,0 z PLAN SPECIFIC GENERAL NOTES: GENERAL ELECTRICAL NOTES: 0 '06/03/2016 1. EC SHALL VERIFY THE LOCA11ON OF ALL EXISTING U11UTIES PRIOR TO CONSTRUCTION AND BE THE FOLLOWNG GENERAL NOTES APPLY TO ALL DRAWNGS RESPONSIBLE FOR SITE INVES11GA11ON PRIOR TO START OF WORK TO REVEAL THE FULL SCOPE 1. nTYPICAL" OF WORK. IN ADDITION, THE EC SHALL THOROUGHLY EXAMINE ALL AREAS WHERE EQUIPMENT, ITEMS NOTED AS ON ANY DRAWNG REFERS TO ALL DRAWNGS. DRAWN CHECKED DATE CONDUIT, AND WRING WLL BE INSTALLED AND WLL REPORT ANY CONDITION THAT PREVENTS 0 z voc THE PROPER INSTALLATION OF THE ELECTRICAL WORK. 2. PROVIDE NYLON PULL STRING IN ALL EMPTY RACEWAYS. 2. EC SHALL COORDINATE NTH THE GC TO PATCH AND REPAIR ALL EXISTING WALLS, FLOORS, 3. NO STRUCTURAL MEMBERS SHALL BE CUT OR ALTERED WTHOUT PRIOR APPROVAL OF THE CEILINGS OR OTHER SURFACES IDENTIFIED TO REMAIN THAT MAY BECOME DAMAGED DURING ARCHITECT AND STRUCTURAL ENGINEER. THE COURSE OF WORK. 4. LOCATIONS OF ALL MOUNTED DEVICES ARE SHOWN SCHEMATICALLY. COORDINATE WTH THE 3. EXPOSED/SURFACE MOUNTED CONDUITS SHALL ONLY BE ALLOWED WERE NECESSARY IN 0 ARCHITECTURAL DRAWNGS, ELEVATIONS AND CASEWORK SUPPLIERS SHOP DRAVANGS FOR < EXPOSED CElLING AREAS. IF CONDUITS NEED TO BE SURFACE MOUNTED TO WALLS, EXACT LOCATION OF DEVICES PRIOR TO ROUGH IN. u') 0.) COORDINATE WTH OWNER OR OWNER'S REPRESENTATIVE FOR APPROVAL AND SEE SPECS FOR 5. RACEWAYS IN FINISHED SPACES SHALL BE CONCEALED. FURTHER INFORMATION. 6. PROVIDE 2" EMT SLEEVES FOR LOW VOLTAGE WRING RUNNING THROUGH NON -RATED WALLS, 4. VERIFY LOCATION OF ALL OUTLETS AND SWTCHES WTH ARCHITECTURAL DRAWNGS, INTERIOR w FLOORS AND CEILINGS. DETAILS, FINISH SCHEDULES, GENERAL CONTRACTOR, EQUIPMENT VENDORS, OWNER OR OWNER'S 0� REPRESENTATIVE AND EXISTING SITE CONDITIONS. VERIFY FINAL DOOR HINGE LOCATION PRIOR 7. PROVIDE STI "EZ -PATH" ASSEMBLIES AT EACH LOCATION WIERE LOW VOLTAGE WRING TO SWTCH INSTALLATION AND ADJUST SWTCH LOCATION IF NEEDED. DO NOT MOUNT RECEPTACLES/SWTCHES IN LOCATIONS THAT WOULD CONFLICT WTH MIRRORS, SEAMS OF PENETRATES A RATED WALL OR CEILING. ASSUME 50 ARE TO BE PROVIDED. WALLS, WAINSCOTS, TILE TRANSITIONS, ETC. 8. SEAL PENETRATIONS IN RATED FLOORS AND CEILINGS WTH A UL APPROVED FIRE STOP 5. DRAWNGS ARE DIAGRAMMATIC AND INDICATE GENERAL INTENT OR ARRANGEMENT OF SYSTEM. SYSTEMI(S). FOLLOW DRAWNGS IN LAYING OUT WORK AND COORD. WTH OTHER TRADES TO 9. PROVIDE A COMPLETE DESIGN -BUILD PATHWAY SYSTEM FOR ALL POWER & SPECIAL SYSTEMS VERIFY SPACE COND111ONS AND CLEARANCES. MAINTAIN HEADROOM AND SPACE CONDITION. WRING, SEE SPECIFICATIONS. QUANTITY AND SIZE OF RACEWAYS SHOWN ON POWER & SPECIAL MAKE APPROPRIATE ADJUSTMENTS AT OWNER OR OWNIER'S CONTRACTOR'S DIRECTION. SYSTEMS PLANS ARE THE MINIMUM TO BE PROVIDED. CONTRACTOR SHALL PROVIDE ALL RACEWAYS AS REQUIRED. 6. COORDINATE WTH OTHER TRADES FOR ANY NEEDED LOW VOLTAGE CONTROL WRING AND DEVICES THAT IS NEEDED BUT MAY NOT BE SHOWN IN THESE DRAWNGS. 10. LOW VOLTAGE WRING NOT RUN IN A METALLIC RACEWAY SHALL BE PLENUM RATED. 7. TEMPORARY POWER: REUSE EXISTING PANEL (IF IN GOOD CONDITION) AND SERVICE FOR 11. EQUIPMENT, LUMINAIRES, RACEWAYS, DEVICES, ETC. SHALL BE UL LISTED. TEMPORARY CONSTRUC11ON POWER. ALL RECEPTACLES TO BE USED DURING CONSTRUCTION SHALL BE GFI PROTECTED. 12. MOUNT DEVICES ABOVE COUNTERS 6" A13OVE BACKSPLASH UNLESS NOTED OTHERNSE, 8. All ELECTRICAL SYSTEMS SHALL BE TESTED FOR PROPER OPERATION. BALANCE ALL BRANCH 13. WERE A CONFLICT EXISTS THE MOST EXPENSIVE OP11ON SHALL GOVERN. CIRCUITS LOADS BETWEEN THE PHASES OF THE SYSTEM TO WTHIN 10% OF THE HIGHEST PHASE LOAD IN EACH PANELBOARD. 14. PROVIDE RACEWAYS AND WRING REQUIRED TO INSTALL ELECTRONIC DOOR HARDWARE. REFER TO DOOR HARDWARE SPECIFICATION, SCHEDULES AND DIAGRAMS. 9. THE EC SHALL SCHEDULE ALL ELECTRICAL SYSTEM(S) SHUTDOWNS WTH THE GENERAL CONTRACTOR AND LANDLORD AT LEAST 24 HOURS IN ADVANCE. UNLESS APPROVED OTHERWSE ALL SHUTDOVMS SHALL OCCUR BETKEN ll:OOPM AND 5:OOAM. EQUIPMENT CONNECTIONS 1. VERIFY ELECTRICAL REQUIREMENTS WTH MANUFACTURER SHOP DRAWINGS PRIOR TO GENERAL ROUGH -IN. NOTE: "CONTRACTOR" MEANS "ELECTRICAL CONTRACTOR" WiEN REFERENCED ANYWHERE IN THE 2. INSTALL AND WRE EQUIPMENT PER MANUFACTURER SHOP DRAWNG. ELECTRICAL CONSTRUCTION DOCUMENTS UNLESS WORK AND EQUIPMENT HAS BEEN COORDINATED BETWEEN THE ELECTRICAL AND GENERAL CONTRACTORS TO BE PROVIDED BY. 3. PROVIDE ALL RACEWAYS, WRING ONLY AS SHOWN ON MANUFACTURER SHOP DRAWNGS. THE GENERAL CONTRACTOR. 'NEDED*, OPROVIIDE", AND mINSTALL7 MEANS ALL ITEMS CALLED OUT IN THE CONTRACT DOCUMENTS AND ANY ADD11IONAL ITEMS NOT CALLED OUT BUT 4. PROVIDE HARDWRED CONNECTION, RECEPTACLE OR FUSED DISCONNECT SWTCH ON REQUIRED TO MAKE A COMPLETE AND OPERA11ONAL SYSTEM. MANUFACTURER SHOP DRAWNGS. SCOPE THE INTENT OF THE DRAWNGS IS TO PROVIDE A COMPLETE AND FULLY OPERATIONAL ELECTRICAL SYSTEM. THE ELECTRICAL CONTRACTOR SHALL FURNISH AND INSTALL ALL LABOR, MATERIAL AND EQUIPMENT NECESSARY TO COMPLETE THE ELECTRICAL WORK. POWER & SPECIAL SYSTEMS PLANS PERMITS AND FEES THE FOLLOWNG GENERAL NOTES APPLY TO ALL POMR & SPECIAL SYSTEMS PLANS, THE ELECTRICAL CONTRACTOR SHALL PROCURE AND PAY FOR ALL PERMITS, FEES AND INSPECTIONS NECESSARY TO COMPLETE THE ELECTRICAL SCOPE OF WORK PRIOR TO STARTING THE WORK. 1. CIRCUIT ALL FIRE/SMOKE DAMPERS AND SMOKE DAMPERS FROM NEAREST 120V EMERGENCY PANEL NTH r EMT CONDUIT, (3) #12 AWG. RECORD CIRCUITING ON AS -BUILT DRAWNGS. WARRANTY REFER TO MECHANICAL DRAWNGS FOR DAMPER LOCATIONS. THE ELECTRICAL CONTRACTOR SHALL UNCOND111ONALLY WARRANTY ALL WORK TO BE FREE OF DEFECTS IN MATERIAL AND WORKMANSHIP FOR A PERIOD OF ONE (1) YEAR FROM THE DATE 2. PRIOR TO ORDERING EQUIPMENT OR ROUGH -IN, COORDINATE WTH THE MECHANICAL OF FINAL ACCEPTANCE BY THE OWNER OR OWNER'S REPRESENTATIVE AND WLL REPAIR OR CONTRACTOR TO ESTABLISH THE ACTUAL LOAD AND OVERCURRENT PROTECTION REQUIREMENTS REPLACE ANY DEFECTIVE WORK PROMPTLY AND WTHOUT CHARGE AND RESTORE ANY OTHER FOR EACH PIECE OF EQUIPMENT. EXISTING WORK DAMAGED IN THE COURSE OF REPAIRING DEFECTIVE MATERIALS AND WORKMANSHIP. 3. REFER TO MECHANICAL EQUIPMENT CONNEC11ON SCHEDULE FOR EQUIPMENT RATINGS AND FEEDER SIZES. CODES PERFORM ALL WORK IN ACCORDANCE NTH THE CURRENT NATIONAL ELECTRICAL CODE, STATES, 4. PROVIDE DISCONNECT SOTCH OR COMBINATION STARTER FOR EACH PIECE OF EQUIPMENT AS CITY ELECTRICAL CODES, AND ALL OTHER APPLICABLE CODES INCLUDING ANY STATE OR LOCAL SHOWN ON MECHANICAL EQUIPMENT CONNECTION SCHEDULE. ENERGY CODES. ALL WORK SHALL ALSO BE IN COMPLIANCE NTH BUILDING OWNER'S CRITERIA. IN CASE OF CONFLICT BETWEEN THE DRAWNGS, SPECIFICATIONS, CODES, ORDINANCES, AND 5. PRIOR TO ROUGH -IN OF ALL EQUIPMENT SPECIFIED BY OTHER DIVISIONS COORDINATE WTH THE AUTHOR111ES HAVING JURISDICTION, THE MOST STRINGENT STANDARD (IN THE OPINION OF THE EQUIPMENT MANUFACTURER TO ESTABLISH ALL REQUIREMENTS FOR EACH PIECE OF EQUIPMENT. ENGINEER) SHALL APPLY. THE EC SHALL SATISY CODE, AHJ, DRAWNGS, AND SPECIFICATIONS AS A MININUM STANDARD WTHOUT ANY EXTRA COST. 6. EXTERIOR RECEPTACLES SHALL BE WP/GFCI. STANDARDS 7. HOMERUNS OVER 100' SHALL BE #10 AWG MINIMUM. EQUIPMENT AND MATERIALS SHALL CONFORM WTH APPROPRIATE PROVISIONS OF NEC, WAC, ASTM, UL, ETL, NEMA, ANSI, AND OTHER APPLICABLE AGENCY AS THEY APPLY TO EACH 8. POWER AND SPECIAL SYSTEMS TO SHARE A COMMON FLOOR BOX. INDIVIDUAL UNIT OR ASSEMBLY. 9. FEEDER ROUTING SHOWN IS APPROXIMATE. COORDINATE WTH MECHANICAL SYSTEMS AND BUILDING STRUCTURE. PROVIDE OFFSETS AS REQUIRED. 10. RECEPTACLES WTHIN 6 FEET OF A SINK SHALL BE A GFCI TYPE. BASIC MATERIALS AND METHODS 11. MINIMUM RACEWAY SIZE SHALL BE r FOR ALL OTHER SYSTEMS. MATERIALS: PROVIDE ALL NEW MATERIAL AND EQUIPMENT UNLESS NOTED OTHERWSE. ALL EQUIPMENT SHALL BE UL APPROVED, LABELED, AND LISTED OR OTHER APPROVED TESTING 12. POWER AND SPECIAL SYSTEMS WRING SHALL BE RUN UTILIZING OPEN WRING METHOD ABOVE ORGANIZATION WHICH HAS ACCEPTANCE BY THE AUTHORITIES HAVING JURISDIC11ON FOR THE ACCESSIBLE CEILINGS. PROVIDE METALLIC RACEWAYS FOR WRING INSTALLED IN WALLS, ABOVE PURPOSE FOR WHICH THEY ARE USED. IN ADDITION, MEETING ALL REQUIREMENTS OF THE INACCESSIBLE CEILING, WIERE EXPOSED OR WHERE SUBJECT TO PHYSICAL DAMAGE. RACEWAY CURRENT APPLICABLE CODES AND REGULATIONS. NO SUBSTITUTION OF MATERIALS SPECIFIED FILL SHALL NOT EXCEED 4OX VALL BE ALLOWED UNLESS NOTED OTHERWSE. ALL ITEMS ARE NEW UNLESS OTHERMSE NOTED. 13. PROVIDE FIRE ALARM CONNECTION TO FIRE SPRINKLER TAMPER, FLOW, AND PRESSURE CUTTING AND FITTING-. PERFORM CUTTING, CORING, FITTING, REPAIRING AND FINISHING OF THE SWTCHES. REFER TO MECHANICAL DRAWNGS FOR LOCATIONS. WORK NECESSARY FOR THE INSTALLA11ON OF THE EQUIPMENT. HOWEVER, NO CUTTING OF THE WORK OF OTHER TRADES OR OF ANY STRUCTURAL MEMBER SHALL BE DONE WTHOUT THE 14. PROVIDE r A -C FIRE RETARDANT PLYWOOD ON SERVER ROOM WALLS FORE TELE/DATA CONSENT OF THE ARCHITECT, CONSTRUC11ON MANAGER, GC, AND/OR OWNER. PROPERLY FILL, BACKBOARD. MOUNT 8' DIMENSION VER11CAL SEAL, FIREPROOF, AND WATERPROOF ALL OPENINGS, SLEEVES AND HOLES IN SLABS, WALLS, AND CASEWORK. 15. STAPLES SHALL NOT BE USED TO SECURE LOW VOLTAGE CABLING. 16. CABLING NOT RUN IN A METALLIC RACEWAY SHALL BE PLENUM RATED. ONE LINE DIAGRAM 1. FEEDERS ARE ALUMINUM NTH THHN/THWN INSULATION. 2. PROVIDE PULL BOXES AS REQUIRED BY THE NEC. 3. SHORT CIRCUIT CURRENTS LESS THAN 10,000 AIC FOR 208V PANELS AND 14,000 AIC FOR 480V PANELS ARE NOT SHOWN. 4. THE ONE -LINE DIAGRAM IS DIAGRAMMATIC AND DOES NOT SHOW THE ACTUAL ROUTING OF RACEWAYS. 5. FOR TWO SEC11ON PANELS PROVIDE FULL SIZE FEEDER CONNECTIONS FROM SECTION 1 TO SECTION 2. 6. NOT ALL CIRCUIT BREAKERS ARE SHOWN, REFER TO PANEL AND S"TCHBOARD SCHEDULES FOR OTHER LOADS SERVED, AND SPARE CIRCUIT BREAKERS. BRANCH CIRCUIT WIRING. 1. IN GENERAL ONLY CIRCUIT NUMBERS HAVE BEEN SHOWN ON THE DRAWNGS. THE CONTRACTOR SHALL PROVIDE ALL REQUIRED RACEWAYS AND WRING. 2. SHOW RACEWAYS AND WRING ON AS -BUILT DRAWNGS. 3. GENERAL: - 3.1. MINIMUM RACEWAY SIZE SHALL BE r EMT 3.2. NO MORE THAN 6 #12 AWG CONDUCTORS SHALL BE INSTALLED IN A RACEWAY, 3.3. HOMERUNS GREATER THAN 100 FEET TO THE FIRST DEVICE SHALL BE #10 AWG. 3.4. LIGHTING, POWER AND MECHANICAL EQUIPMENT CONDUCTORS SHALL NOT BE COMBINED IN THE SAME RACEWAY. 3.5. PROVIDE A GROUND CONDUCTOR IN ALL RACEWAYS. 3.6. PROVIDE A DEDICATED NEUTRAL CONDUCTOR FOR EACH BRANCH CIRCUIT. BREAKER TIES OR MUL11-POLE BREAKERS MAY BE USED IN LIEU OF A DEDICATED NEUTRAL 4. LIGHTING - 4.1. PROVIDE CONDUCTORS AS REQUIRED TO PROVIDE CIRCUITING AND SWTCHING DUTY AS SHOWN ON THE DRAWNGS. 4.2. PROVIDE A DEDICATED NEUTRAL CONDUCTOR FOR EACH BRANCH CIRCUIT. BREAKER TIES OR MULTI -POLE BREAKERS MAY BE USED IN LIEU OF A DEDICATED NEUTRAL 5. POWER: 5.1. PROVIDE CONDUCTORS AS REQUIRED TO PROVIDE CIRCUITING SHOWN. 5.2. FOR OTHER THAN 15 OR 20 AMP SINGLE PHASE RECEPTACLE BRANCH CIRCUITS PROVIDE A DEDICATED HOMERUN TO THE PANEL 5.3. FOR 30 AMP BRANCH CIRCUITS PROVIDE #10 AWG CONDUCTORS. FOR 40 AMP AND LARGER BRANCH CIRCUITS PROVIDE RACEWAYS AND WRING AS SHOWN ON THE DRAWNGS. 5.4. PROVIDE A DEDICATED NEUTRAL CONDUCTOR FOR EACH BRANCH CIRCUIT. BREAKER TIES OR MULT1-POLE BREAKERS MAY BE USED IN LIEU OF A DEDICATED NEUTRAL 6. MECHANICAL EQUIPMENT. PROVIDE RACEWAYS AND WRING AS SHOWN ON THE MECHANICAL EQUIPMENT CONNECTION SCHEDULE. 8 04 Z C3 CL cr RACEWAYS PROVIDE CODE APPROVED WRING METHODS FOR BRANCH CIRCUITING INDOORS, SUCH AS EMT CONDUIT WITH COPPER CONDUCTORS OR MC CABLE (PROVIDED IT IS CONCEALED FROM MEW AND NOT EXPOSED). ALL ABOVE GROUND CONDUITS SHALL BE EMT OR RIGID, MINIMUM 1/2- IN SIZE (LION). CONDUITS SHALL BE SIZED PER CODE AND AS NEEDED TO INSTALL CONDUCTORS. CONDUIT CONNECTORS SHALL BE DOUBLE LOCKNUT TYPE, UL LISTED AND LABELED, WTH COMPRESSION OR SET SCREW FITTINGS. PVC CONDUITS ARE NOT ALLOWED ABOVE SLAB UNLESS CODE AND AHJ APPROVED/LISTED FOR THAT USE. CONDUIT RUNS ON EXTERIOR OF BUILDING SHALL BE CONCEALED AND BE RIGID STEEL CONDUIT WTH WEATHER TIGHT, CORRISION-RESISTANT FITTINGS (OR PVC wHERE LISTED FOR EXTERIOR -SUNLIGHT USE). CONDUIT SHALL NOT BE RUN EXPOSED WTHOUT SPECIFIC PERMISSION FROM THE CONSTRUCTION MANAGER. WHERE RACEWAYS ARE INSTALLED FOR OTHERS TO USE, OR FOR FUTURE USE, PROVIDE NYLON PULL STRINGS END TO END NTH A LABEL ON BOTH ENDS STATING USE AND LOCATION OF OTHER STUB (E.G. DATA -FRONT POS). PENETRATIONS THROUGH FIRE RATED CONSTRUCTION SHALL BE SEALED USING 3M FIRE BARRIER CAULK, NELSON ELECTRIC FLAMESEAL OR T&B FLAME SAFE OR OTHER METHOD APPROVED THE ARCHITECT AND AHJ. CONDUIT RUNS CONCEALED IN CONCRETE OR UNDERGROUND SHALL BE 3/4- MINIMUM, UNLESS OTHERMSE NOTED W/RIGID STEEL ELBOWS. CONDUIT CONNECTORS SHALL BE DOUBLE LOCKNUT TYPE, UL LISTED AND LABELED, NTH COMPRESSION OR SET SCREW FITTINGS. IF CONDUIT RACEWAYS CANNOT BE RECESSED IN WALLS DUE TO CONSTRUCTION OR EXISTING CONDITIONS, PROVIDE A STEEL SURFACE MOUNTED RACEWAY SYSTEM (VAREMOLD, HUBBEL OR APPROVED EQUAL) NTH ALL COMPATIBLE DEVICES. THIS TYPE OF SYSTEM IS ONLY ALLOWED WfHERE APPROVED BY OWNER OR OWNER'S REPRESENTATIVE INCLUDING LAYOUT. CONFIRM COLOR AND ANY CUSTOM FINISHES NTH OWNER OR OWNER'S REPRESENTATIVE. CONDUCTORS AND TERMINATIONS CONDUCTORS: SHALL BE ALUMINUM, INSULATED FOR 60OV, TYPE THWN/THHN, NUMBER 12 AWG MIMIMUM UNO. MOTORS AND OTHER WRING: THE ELECTRICAL CONTRACTOR SHALL PROVIDE ALL NEEDED CONDUIT, WRING, CONNECTIONS, AND SAFETY SWTCHES FOR ALL MOTORS, AND EQUIPMENT, EVEN IF THE MOTORS AND EQUIPMENT ARE SUPPLIED BY OTHERS. MOTORS, CONTROLS, ETC. MAY BE FURNISHED BY THE SUPPLIER OF THE DRIVEN EQUIPMENT. THE ELECTRICAL CONTRACTOR SHALL INCLUDE ALL WORK AND CONNECTIONS NEEDED TO MAKE THE SYSTEM COMPLETE AND OPERA11ONAL ALL ELECTRICAL CONNECTIONS TO MECHANICAL EQUIPMENT SHALL BE DONE BY THE ELECTRICAL CONTRACTOR. THE ELECTRICAL CONTRACTOR SHALL VERIFY EQUIPMENT LOCATION AND SIZES WTH THE TRADE AND VENDOR SUPPLYING THE EQUIPMENT PRIOR TO ROUGH -IN. GROUNDING ALL MAJOR PARTS NOT CARRYING CURRENT, INCLUDING BUT NOT LIMITED TO, SECONDARY FEEDER CIRCUIT, EQUIPMENT AND PANELBOARD ENCLOSURES, PULL AND JUNCTION BOXES AND OTHERS DEFINED BY CODE, SHALL BE PROPERLY GROUNDED. METALLIC RACEWAYS SHALL UTILIZE DOUBLE LOCKNUTS AND OTHER FITTINGS TO PROVIDE GROUND CONTINUITY. SWITCHES AND RECEPTACLES SWTCHES: GRADE OR APPROVED EQUAL WTH DURABLE COVERPLATES. COORDINATE WTH OWNER OR OWNER'S REPRESENTATIVE DM FOR COVERPLATE TYPE (E.G. STAINLESS STEEL) AND FOR COLOR OF SWTCH AND PLATE. RECEPTACLES: GRADE OR APPROVED EQUAL WTH DURABLE COVERPLATES. COORDINATE WTH OWNER OR OWNER'S REPRESENTATIVE DM FOR FOR COVERPLATE TYPE (E.G. STAINIESS STEEL) AND FOR COLOR OF RECEPTACLE AND PLATE. INSTALL RECEPTACLES PLUMB, LEVEL, AND SECURE TO J -BOX PROVIDE GFCI TYPE MERE INDICATED AND VMERE REQUIRED BY CODE AND AHJ. GFCI RECEPTACLES SHALL BE CLASS A RATED FOR PERSONNEL PROTECTION.ALL RECEPTACLES ARE TO BE MOUNTED 18" ABOVE FINISHED FLOOR TO CENTER OF DEVICE UNLESS NOTED OTHERVASE. OCCUPANCY SENSORS: SENSORSWTCH WSD SERIES FOR SINGLE OCCUPANT RESTROOMS AND CLOSETS AND SENSORSWTCH CONTRACTOR CHOSEN/OWNER APPROVED (PIR AND ULTRASONIC SOUND ACTIVATED) FOR PARTITIONED RESTROOMS. LOW VOLTAGE ALL LOW VOLTAGE WORK SHALL COMPLY, BE PERMITTED AND INSPECTED PER STATE (AND LAHJ) REQUIREMENTS. ALL LOW VOLTAGE WORK SHALL BE INSTALLED BY A LICENSED CONTRACTOR IN ACCORDANCE NTH THE STATE AND LAHJ REQUIREMENTS. ALL LOW VOLTAGE CABLING INSTALLED UNDERGROUND SHALL BE ROUTED IN A CONDUIT RACEWAY AND CABLING/CONDUCTORS SHALL BE LISTED FOR USE IN WET LOCATIONS, FOR LOW VOLTAGE APPLICATION AND PER LAHJ. ALL LOW VOLTAGE CABLING ROUTED INDOORS SHALL BE ROUTED CONCEALED IN WALLS/CEILINGS IN A CONDUIT RACEWAY (UNLESS OWNER AND LAHJ AUTHORIZE IT TO BE ROUTED EXPOSED THROUGH WALL/CEILING). IF APPROVED BY OWNER & LAHJ TO BE ROUTED EXPOSED, CABLING SHALL BE PROPERLY FASTENED/SUPPORTED PER CODE, LAHJ, AND INDUSTRY STANDARDS. CABLING NOT ROUTED IN CONDUIT SHALL BE PLENUM RATED WfHERE REQUIRED BY CODE OR LAHJ (CONFIRM WHETHER CEILING SPACE IS BEING USED AS AN AIR PLENUM.) ALL LOW VOLTAGE CABLING OUTDOORS (E.G. ON ROOF) SHALL BE ROUTED IN CONDUIT PER CODE AND LAHJ REQUIREMENTS UNLESS SPECIFICALLY LISTED AND LABELED FOR EXTERIOR USE. PANELBOARDS PANELBOARDS SHALL HAVE PLUG-IN OR BOLT ON BREAKERS AND MAIN LUGS ONLY OR MAIN BREAKERS AS NEEDED OR REQUIRED. PANELBOARDS SHALL BE CONSTRUCTED NTH ALUMINUM BUS AND BE ENCLOSED IN NEMA 1 HOUSING (OR AS REQD BY CODE). ENCLOSURE(S) SHALL BE COMPLETE NTH A HINGED DOOR, CYLINDER LOCK, AND A NEATLY TYPED CIRCUIT BREAKER DIRECTORY UNDER PLASTIC COVER IN EACH PANEL ALL MULTIPLE POLE BREAKERS (AND OTHER BREAKERS REVD BY CODE) SHALL HAVE A COMMON TRIP HANDLE. FUSED SWITCHES FUSED SWTCHES: HEAVY DUTY TYPE, HORSE POWER RATED NTH INTERLOCKING COVER. NEMA 1 TYPICAL OUTDOORS AND WET LOCATION SNTCHES SHALL BE RAINTIGHT TYPE NEMA 3R. ALL SWTCHES SHALL BE LOCKABLE. FUSES IN CIRCUITS RATED AT 600A OR LESS SHALL BE UL CLASS RKII DUAL -ELEMENT, TIME DELAY, CURRENT LIMITING FUSES. FUSES IN CIRCUITS RATED AT 601A OR LARGER SHALL BE UL CLASS L TIME -DELAY, CURRENT LIMITING SWTCHES. MOUNTING-.'. MOUNT DISCONNECTS TO STRUCTURE, INDEPENDENT OF THE MECHANICAL UNIT HOUSING OR WTH INDEPENDENT UNISTRUT SUPPORT. DISCONNECTS MOUNTED TO UNITS ARE ONLY ALLOWED WlIERE ACCEPTED BY THE LOCAL CODE AUTHORITY AND LOCATED SO AS TO NOT BLOCK ACCESS OR LABELS OF UNIT. NAMEPLATES PROVIDE PHENOLIC NAMEPLATES ON ELECTRICAL DEVICES SUCH AS DISCONNECTS AND PANELS NTH THEIR DESIGNATION (E.G. "PANEL A*). PROVIDE DIRECTORY FOR PANELS AND LABEL ALL BREAKERS. IF A TRANSFORMER IS INSTALLED, PROVIDE NAMEPLATE ON TRANSFORMER AS FOLLOWS: "HOT SURFACE, DO NOT PLACE ANY ITEMS ON TOP OR ON SIDES OF TRANSFORMER". uj r 100A PAS p,FcFj\jEo cl-fy OF Tuyv4jL_A T C;FN.TER 0,0 z DATE 05/02/2016 0 '06/03/2016 DRAWN CHECKED DATE oc 0 z voc oc T, < U-) z 0 q;j- < P u') 0.) w 0� REV# DATE 05/02/2016 '06/03/2016 DRAWN CHECKED DATE cm Cm 06/06/2016 ELECTRICAL NOTES PANEL A (SEC 142 150kVA ) MAIN DISTRIBUTION SWITCHGEAR (MDS) • 1600A, 480Y/277V, 3P, 4W, NEMA 1 65,000 AIC W. 0 %A7 (4) 3• EMT (4) 500 KCMIL AL (1) #2G AL (2) 3• EMT (4) 500 KCMIL AL (1) #2G AL 1 L------------------------0- 0 CD IE 0 PANEL COMP GENERAL NOTES: 1. ALL CONDUCTORS ARE #12 AWG CU UNLESS NOTED OTHERWISE. MC FEEDER CAN BE USED WHERE APPROPRIATE AND AT CONTRACTOR'S DISCRETION. MC FEEDER SHALL BE SIZED PER NEC REQUIREMENTS. 2. MULTI—WIRE BRANCH CIRCUITS SHALL MEET NEC 210.4 REQUIREMENTS. 3. COLOR OF ALL WIRING DEVICES AND COVER PLATES SHALL BE AS SELECTED BY THE ARCHITECT, U.N.O.. VERIFY WITH ARCHITECT PRIOR TO ORDERING. 4. COORDINATE ALL CABLE PATHWAY ROUTING IN STRUCTURE, FINISHES AND OTHER TRADES PRIOR TO ROUGH—IN. 5. EQUIPMENT SHOWN BOLD IS NEW. 6. EQUIPMENT SHOWN DASHED IS EXISTING. FLAG NOTES: INTERCEPT EXISTING RACEWAYS AND FEEDERS AT EXISTING JUNCTION BOX AND EXTEND AS INDICATED. [A PANEL T1 (SEC 1 2+3) M M I M-2 DATE co LO 1 C-4 T 0 06/03/2016 N co 0 1 CM LO N v ( /� � €� ULu 13 o z° 0- 0 U Ln UW Lu Lu W F_ U) a 0 0 , M 0 0 0 0 0 0 0 0 o s o 0 0 0 0 0 o a o 0 0 0 Fastenal 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 Consignment POWER PLAN SCALE: 1/8" = 1'-0» • • • REVIEWED FC B COMPLIANCE WITFL NFPA 70 - NEC JUL 01 2016 rIt • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • E C �g DATE co LO 1 C-4 T 0 06/03/2016 N co ti 00 w CM e DATE co LO 1 C-4 T 0 06/03/2016 N co ti 00 CHECKED CM LO N v co N � ULu z z x LL z° 0- 0 U UW Lu Lu W F_ U) uj WN 04 N _ O 0) o C° z Y I-- REV # DATE Qi 05/02/2016 0 06/03/2016 DRAWN CM CHECKED CM DATE 06/06/2016 NORTH POWER PLAN Eli REC (L16 -20R) -MACHINE SHOP DATE MISC r') ON L!7 r L 1 2G 3 1 1 CVN Do Do 2 1 3 1 20 3.33 CO 00 Lo lf) C14 C14 MISC 3.33 - VOLTS:: 480 Y/ APC RATING:. 66.000 NEUTRAL 100% U 0 LL !. _ a PANEL SCHEDULE 3.33 PANEL SCHEDULE PANEL:: SDP -1 OCAiK)N `MACHINE ROOM VOLTS: 480: Y/ 277; P'3 IN,: .4 _...__ .... .......... ... _ ....... ..._... _..... .. _ ...... ........ :......... _ ... ...._ AMP: MLO MCB X 12.OD ........... _ ❑..... .........._ _ AIC RATING:; 65.000: MOUNT ': X SURFACE FLUSH 3.33 PANEL:' (_'� SEG LOCATION:: MACHINE ROOM VOLTS: 208: (SEC ) _ . ....._ _ _ - AMP:f MLQ M Y/ 120: P:3 W: 4 .._._ .__ .. _ - - ❑ 6 - - TYPE:' EXiST X SNEUTRAL`- , _IND NEW ❑....,_ TYLE;; 100% FED FROM, MAINDISTRIBUTiONSWITCHBOARD MSB ❑.... ..._..__...< _.._... ...- _ ..- __.... _...-.... _.__....(....._} MISC - ..... .... _:. - _ TYPE:. EXISTING I --I NEW X STYLE:. _ _.❑.. NEW _ _ .__ _._ NEUTRAL: aMiSC _ ......_. - . FED FROM.:.SDP i iA150KVAXFMR 3.33 20 ' gRCU1TDESCRIPTION : ; LDAD TYPE LOAD KYA CKT BKR P qR # P H CIR # P CKT BKR LOAD KV0. LOAD TYPE - :. gRCL11TDE5CtgP1ION 9 t gRCUITDESCRIPT}ON; LOAD - TYPE LOAD CKT P ..KVA.._ BKR .... OR 5.... P ti CR 0 P CKT _.. -6KR. LOAD LOAD i _. KVA ... T1PE. _ _... gRCF1LTOE5CibPTON.... .. ..-... -.. _ 3.33 - PANEL H t (SEC 1+2 COMB 80.44 400 3 1 A 2 3 140 11.63 MISC EQUIPM-NT#756 (55 TON 13 EQUPMENT#750 (55 TON) MISC 7,09 100 3 1 A 2 3 30 2.16 MISC REC (1_15-30R)MACHINE SHOP 333 W U W - COMB 80.44 - - 3 B 4 - - 11.63 MISC - 17 C A B FAISC 7,09 _ 3 e 4 - - 2.16 MiSC --- ------ ----- - COMB -- - 8044 _ - - 5 C -6 --- -._- .. 11.63 _MiISC--- -- ----- - -MISC - -- - - - - ---- - -- - MISC - - _- -- - 7.09 - -- 5 C ---- 6 - -- - -- ----- --------------- ---- 2.16 MISC - PANEL L1 (VIA 15CKVA XFMR1 COMB 31.69 200 3 7 8 3 100 11.63 MISC EQUIPMENT#757 (80 TON) EQUIPMENT#753 (330 TON) MISC 5.04 100 3 7 A 8 3 30 2.16 MISC REC (L15-30R)-h4AC�NE SHOP ... _..._ _ ... .. ..... RESIDENTLTG/RECPT .RES A B W - COMB 31.69 - - 9 B 10 - - 11.63 MISC - 8.31 - MISC 5.04 - 9 B1. 10 - - 2.16 MISE - - C0141B 32.05 - - 11 C 12 35 - 11.63 MISC - - -ti - -- --._ h41SC 5.04 - - 1i C 12 - - 2.16 MiSC A B 36 40 3 20 - EQUPh1ENT4751 60 TO --__{ .--- N} _ MISC MISC 11 36 11.36 idd - 3 - 13 15 14 1`6 - app - 52.37 52.37 MISC MISC EQLiPtd_hT#758 (120 TON) - A B 20 - - = _QUv�MiEhT 7 4 ,<OO TON) - MISC 5.52 100 3 13 A B - - 14 3 30 - - - ---- - _ - - - - 2,16 MISC REC (LI5-3OR)-MACHINE SHOP Q N W N O _ )- j o to - Lo W Y - -- - - - --- - MISC 5.52 - - 15 16 - - 2.16 M{SC - CONNECTED PHASE LOADING _...... .........: __.... .. _ .._....._..... PHASE A: 80.44+KVA ......... ..... .. ... PHASE B: i 80.44 KVA _. _ _... . - -.-- .. _ PHASE C:[ 80.d4-KVA MISC 1136 - - 17 C 18 - - 52.37 MISC 109 .... ...... .. ........ MISC 5.52 - - ---- ---- 17 19 -- 2 1 _. C A B 18 - - 2.15 MISC - EQUIPMENT #752 (30C TON) - - ----- --- -- - - ,_--- _.. _.. ---- --------- - - -- -- -- - MISC MISC ----- - 30.48 - - 30.48 --- - 125 - - - --- 3 - -- 19 - -- - 21 - - A B C 20 --- --- 3 - - - - - --- -- ---- ------ SPACE -- - ------- -- SPACE SPACE 2D - ----- 2 -3 30 --- - - -- - - - 45-3 - --= - --- --- -- 2 MISC REC - R)-MAC;-t;� SHO? .16 22 - -- 38 - - - ------ - . -- ------ - ----- --- 2.16 MISC _ - MISC 30.48 - SPARE 23 24 - - 40 1 -- - - -- - --- - REC (DED)- MACHINE SHOP REC 0.36 20 1 23 - - 20 - - - EOU PhiENT#753 (330 TON) MISC 20.23 100 3 25 A 26 3 SPACE - SPACE REC (DED)- MACHINE SHOP - -------- - -- -- REC (DED)- h-1ACHINE SHO? REC REC 0.36 20 1 - ..... - _ 0:36 20 1 25 -------- 27 A B �6 2$ 3 30 ---- -- - - 2.1n MISC ftEC (Lt5 30R)-M1AC �1N=SHOP - -- - - 2.16 hiISG - MISC 2023 - - 27 B 28 - - - SPACE ) - ---- - _. _- --- - - -.- - MISC- 023 ' -- -- -- - -- 29 - C 3D - =--- ---------- SPACE - REC (DED} -MACHINE SHOP : REC 0.36 20 1 29 C 30 - - 2.16 MISC EQU�MENT#754(<^OdTON) 17.18 1d0 3 REC(DED)-h4ACHiNESHOP REC 0.36 20 1 31 A 32 -- 3 30 2_i6 MISC REC (LtS30R)-hfAC 4N=SHO? 0.00 KVA (125%) MISC 31 A 32 3 x . ............... ... ....._. .. ..... .. CONNECTED PHASE LOADING RESIDENT LTG/RECPT RES _._... 01.0.011.1 KVA __._... . SPACE - MiSC 17.18 - - 33 34 - - ..... ......_..._ ........ _........ _... _ ......_.. __... PHASE B: 50.51 KVA - ------- - ,. _ REC (DED)- MACHINE SHOP REC- - - 0.36_ 20 1 -- 33 -- _ - 2.16 -- MISC-- - -- --- --- - i B PHASE C 50.51 KVA S 34 - - - - ----------------- _._ - MiSC 17.18 - - --- 35 C 36 - - COMPUTER RECPT MiSC - DOD KVA (100%) REC (DED)- M4ACH(NE SHCP -- - - REC - - 0.36 20 -- - 35 -- - - -- 2.16 -MISC- -- - - --- -- ----- - - -- .. 18.95 KVA C - 36 REC(DED)-MIACHINESHOP REC 0,36 20 1 37 A 38 SPACE MST BEPROVDED4V(THAPEANSTHAFWtILSIPAILTAPIEOUSLYDISGONNECFALLUNGROUNDED EQUIPMENT:755(50'TON) -- -- Mac ----- 1607 -- .... 100 3 ---- 37 --- A 38 3 - - - -- - --- - - - - .... TOTALS _._ - ' -.....-- 15154 KVA _ __ SPACE ( _ - ---- - - FLAG NOTES MISC 16.07 - 19227 -AMPS 39 B 40 - - - - -- LOAD TYFE NOTES iREC{DED)-MACHiNESHOP - - _ REC - -0.36 20 1 -- - 39 B 40 COMB COMBINATION LOAD TYPES ON INDICATED CIRCUIT SPACE - MISC 16.07 - - 41 C 42 - - _. _ _ ._ _.._.... .. EQUF, COMPUTER REC OR HTG LCW D ON INDICATED CffRCUiTAT 100%' - REC (DED) -MACHINE SHOP ' REC: 0.36 20 1 41 C 4Z SPACE ESTIMATED MAXIMUM DEMAND (EMD) CALCULATIONS ESTIMATED MAXIMUM DEMAND (EMD) CALCULATIONS LOAD SUMMARY: LOAD TYPE: CONNECTER I EM.0. CALCULATED . i LOAD SUMMARY. LOADTYPE. COPJNECTED. EM0. CALCEA.ATEO .. _ -._-....... __..... ._.... _..__ .... _......... .................. ......__. UGHTING : LTG 0.00 'KVAOA0 V 12540 KVA - -yY--t - CONNECTED PHASE ----------- - - - o UGHTING LTG 0:00 KVA 0.00 KVA(125/0) _........... CONNECTED PHASE LOADING RESIDENTLTGiRECPT RES OAO KVA O.DO:KVA'(100t35125°rP} __.... .............:.. ......_. ....... ..... _........._..............._._.. _ ...._ . .... PHASE A::##=:KVA _ ............................. ...... ...... .. _ .......... RESIDENT LTG/RECPT !RES 1 0.00 :KVA 0.00 KVA 1 0 013 512 5°!0 - ...: _.._ .. PHASE A: ` 31.69' KVA SMALLAPPLIANCE RES 000 !:KVA 0.00.KVA (1 0 013 512 5%x) PHASE . .,......_..... _..._ ...... ......................,........ .........._... %............. ............................................_ ....._.. -} ........... LARGESTMOTOR t DDO :KVA O.00 KVA PHASE tfKVA LARGESTMOTOR 0.00 KVA 0.00 KVA(125% PHASE C: 32.05 KVA REMNNING MOTORS MTR 13259 :KVA 132.59 KVA (100 m) _._....-_ ......... REMAININ6 MOTORS MTR 0.00 KVA 0.00 :KVA' 100°k) GEN PURPOSE RECPT REC 3.60 'KVA 360 KVA(50%>10KVA) ._ _ GEN PURPOSE RECPT REC 3.60 'KVA 3,60 KVA 50%>10KVA ...... _.... COMPUTER RECPT MISC 0.00 KVA O.OD KVA (100%) GENERAL NOTES: ! COMPUTER RECPT MISC s 0.00 KVA 0.00 KVA (400°k) - ... , GENERAL NOTES: EQUWIOTHER h11SC % 71345 :KVA 713.45 :KVA 100% { ..........) . _......_... ..; ._. i PER NEC210.4(A)&(B)ALLMULTN'VIREBRANCtICIRCUITSSHARNG,ACOMT."ONNEUTRALWIRE ........... _... _.... EQUIP/OTHER : I ° - MISC 91.84 KVA 91.84 KVA (100 k} _.. "" r r 1 PER NEC 210.4 A) & (B) ALL ikb WIRE BRANCH CI}R„U ITS �SHAR FJG A CO M1v1UN NEUTRAL \NIKE HEATING F11SC 0.00 :KVA 000 'KVA 100% _....... !.........................(..........._}... MIUSTBEPROVDEDWffHAhiF�NSTHAT'NILLSt:1ULTAfdEOUSLYDISCONN£CTALLUNGROUNDED _..........-._..... HEATING : MISC I 0-p0 KVA 0.00 KVA 100% MUST BE PRO MEANS IA EANu tATWILL SP.IULTANEOUSLYDtiCONNECT ALL UNGRUUNDED ELEVATOR ECFV €.... 0.00 ;KVA OOO IKVA 100°!o _.. ... .......... CONDl1CTORSATTHEPOiJTOFORGN: CONFRAGTOR'SCHOICE: PROVIDE .. _ .......... ......... _....... .............. .. ........... ..._...... ELEVATOR ECFV 0.00 :KVA 0-00 A °' ............. ............ KV 100 ro CONDUCTORSA T E. SEPARATE T H (DINT OF ORIGIN. CONTRACTOR'S CHOICE: PROVIDE £i TRATE NEUTRALS KITCHEN EQPT KITCH 0.00 KVA 000 KVA 65°k . _<.C FOR BREAKER AS INDICATED OR PROVOS Mi(il_TPOL.F BREAKER.FOR SHARED NEUTRAL. KITCHEN .KITCH 4.00 :KVA 0.00 KVA 5540 POR BREAK P ER AS dDICATED OR PROVIDE MULTI'0LE BREAKER FOR SHARED NEUTRAL_ TOTALS 849.64 !KVA 849.64 ;KVA FLAG NOTES: ... TOTALS € 95.44 :KVA 95.44 KVA .. ..... FLAG NOTES: 1021.95 AMPS 1021 95 :AMPS _.. _.. _ __ - - - _ _ ._....... ....... 1 _ _ _._.. _.._.._. ........ _..., ..... _ __...._..._... 264.90 'AMPS 264.90 'AMPS _.._.... __.. ...-.._. _. 1 ...... .... ..... _ _ _... _ _ _ .. _..._ _ .... _. _..... ......... __ --- LDAD TYPE E NOTES. LOAD TYPE NOTES ; .. ..... _ _._ .. ---- 'COMB' =. COMBINATION LOAD TYPES ON INDICATED CIRCUIT 'COMB COMBINATION LOAD TYPES ON INDICATED CIRCUIT .... .........- "RES"= RESIDENTIAL OR SMALL TAKEN INDICATED DEMAND RES"= RESIDENTIAL LTGIRECPTOR SMALL LOAD TAKEN AT INDICATED DEMAND ............. _. "MISC"= EQUIP, COMPUTER REG OR HTG ON CIRCUiTAT100% "MISC" = EQUIP, COMPUTER REC OR HTG LOAD ON INDICATED CIRCUiTAT 100% ........ _ .... ' REC (L16 -20R) -MACHINE SHOP DATE MISC 3.33 1 2G 3 1 1 JA B C 2 1 3 1 20 3.33 1 MISC REC (L16-20R)-Iv1ACHINE SHOP MISC 3.33 - VOLTS:: 480 Y/ APC RATING:. 66.000 NEUTRAL 100% 3 4 - 3.33 -- MISC - MISC 3.33 - 59 5 6 - - 3.33 MISC - REC(L7620R)- MACHINE SHOP aMiSC CIR # 3.33 20 3 7 A 8 3 20 3.33 MISC REC, (LIG-20R)-MACHINE SHOP - { MISC 3.33- - - - 9 B 10 - - 3.33 MISC - - ---NEUTRAL:J100°ti MISC 3.33 - - 11 C 12 - - 3.33 MISC REC (1_16-20R)-P.tACHINE SHOP I MISC 3:33 20 3 13 A 14 3 20 133 _ MISC REC 0L16 <OR) -MACHINE SHOP - 1 MISC 333 - - 15 B 16 - - 3.33 MISC ,__...,.,.LOAD TYPE ...._-.. KVA BKR.......... MISC 333 - ......... B 17 C A B 18- - 3.33 MISC REC(L16-20R)-MACHINESHOP IMISC 3.33 20 3 19 20 3 20 3.33 MISC REC, (L16^0R)-M1AC,4NESHOP MiSC 3.33 - - 21 22 - 3.33 _ MISC -MISC 88 - 3.33 - - 23 C 24 - - 3.33 MISC REC (L16 -20R) -MACHINE SHOP 90 MISC 3.33 20 3 25 A 26 3 20 91 SPARE 50 .......... .. .. . ......... ..... .... ........ ....... LOAD SUMMARY LOADTYPE CONNECTED EM.D. CALCULATED h4USC 3.33 - ... _..._ _ ... .. ..... RESIDENTLTG/RECPT .RES 27 B 28 - - .......... - SMALLAPPLIANCE RES 0.00 KVA MISC 3.33 - 95 29 31 C A B 30 32 34 - - 3 20 8.31 - SPARE - ------ SPARE PHASE C: 5051:KVA REMAINING MOTORS MTR .. 3 13259 IKVA (100%) .... A 98 33 - . ... ............... ............... ... ................ GENPURPOSE RECPT REC 000 KVA OM ,KVA (50%> 10KVA) - - - 35 C 36 - - EQUIP/OTHER MISC ............ _. SPARE w3 tv95C x 20 - MTR 5.27 37 39 A B 36 40 3 20 - 102 SPARE - -- - ---- ------ `- - -- - - 4 00 !KVA _ _ 0.01D.. KVA (8 :100°° _ ,_ _ 1 - - 41 C 42 - 3 20 FOR BREAKER AS INDICATED OR PROVIDE idULTIFOLE BREAKER FOR SHARED NEUTRAL .-_.... ..... _ TOTALS ....... {_.__.15t54:KVA 151.54 ;KVA . .... ..... ......... .... .. ........... FLAG NOTES" ........ ........_ ..... ........ 1 18227 'AMPS . ........ 182.27 :AMPS ............ - ESTIMATED MAXIMUM DEMAND (EMD) CALCULATIONS ......... . ... .. ... ...< ........... ...... ........................... ....... ....... ... ... .......... ........... ......... _. LOAD TYPE NOTES: SPARE .... _._........ . ......_..... .......... ............. ....... ....... ........ _.....__.._ _._:. LOAD SUMMARY: :LOADTYPP- CONNECTED EM.0. CALCULAT® CONNECTED PHASE LOADING _...... .........: __.... .. _ .._....._..... PHASE A: 80.44+KVA ......... ..... .. ... PHASE B: i 80.44 KVA _. _ _... . - -.-- .. _ PHASE C:[ 80.d4-KVA LIGHTING ...._................ ..LTG O 00 KVA._...0 DDKV . .. (125.../ )......._._..... RESIDENT LTGIRECPT RES 0.00 KVA O OO KVA (1 0 03 5/25 %) ; SI4iALLAPPLL4NCE RES i 0.00 KVA ODD ;KVA (10013512540}_.., LARGESTMOTOR i 0.00 ;KVA ODD KVA 025%) _........... - .. . ,-.... _ _.._ REMAINING MOTORS .......,.., MTR ........ 132.59 KVA . ..,...... 13259:K . GENPURPOSE RECPT REC OOQ `.KVA O.00KVA(50% 10KVA_ RRECPT MISC 00 !KVA 000 COMPUTE d KVA100... 0 EQUIPIOTHER (MISC 108.72 :KVA 108,72 KVA (100%) HEATING MISC O,DO `KVA O.OD 'KVA 100°!° ELEVATOR ECFV 000 KVA 000 'KVA 100 0 k EQPT K TC a KITCHEN I H ODD KVA 000.. KVA fi5,o _.................. _..... - .,........... _.. TOTALS 1 24131 :KVA 24131 `KVA } 290.25 ;AMPS.: 290.25 ;AMPS LOAD TYPE NOTES: GENERAL NOTES: t :PER NEC 210. ) & (B) ALL MULI NIVIRE BRANCH CIRCUITS SHARING ACOMMON NEUIRAL WIRE MUST BE PROVIDEDWITH THAT SirtULTA(VEOUS iAMEANS A WILL LYDISCONNECT ALL UNGROUNDED A _.. CONDUCTORS 7 CONTRACTOR'S RSA THE COtJTRACT CHOICE: T'ROVDE SEPARATE IEUTRALS FOR BREAKER AS �IDICAT R T' I'OLE BREAKER ED 0 ROVDE M1UlT R FOR SHARED NEUTRAL. FLAG NOTES: ._...... t 'COMB" = COMB NATION LOAD TYPES N INDICATE CIRCUIT 'RES "=. RESIDENTIAL LTGIRECPT OR SMALL APPLIANCE VNCE LOAD TAKENATiNDICATED DEMAND "MISC'=. EQUIP, COMPUTER REC OR HTG LOAD ON INDICATED CIRCUITAT100% S?ARE DATE ai 05/02/2016 20 3 55 A 56 3 20 SPARE. PANEL SCHEDULE DATE 06/06/2016 PANEL:: H "I (SEC 2� AMP:1400 MLO ❑X TYPE EXISTING MCS ❑ NEW X LOCATION:. MACHINE ROOM .. ... SME: VOLTS:: 480 Y/ APC RATING:. 66.000 NEUTRAL 100% 277 .. P 3 W:4 MOUNT': ®SURFACE ❑ FLUSH FED FROM: !FEED THRU .......... ... .... ... .............. ..__.... ....... ........_- :............... ......._....._ ..... CIRCUITOESCRIPTION : % LOAD ... ..._... ............ ............................ TYPE LOAD KVA CKT _._...................._.._....... BKR P.f43 59 P.' H CIR P .._... .._.. # .. CKT BKR- LOAD ........._... ...._............. KVA TYPE gRCLATDE5CRIP'IION SPARE P H CIR # 20 3 20 3 62 A 44 3 20 SPARE - 63 B C 64 - - AIC RATING; B 46C 65 66 - --- SPARE STYLE ---NEUTRAL:J100°ti 3 2O 3 67 A 48SPARE' 3 20 SPARE _----- FED FROM ._;FEEDTHRU-- ................... .. ..: - - 20 3 70 A B 50 3 20 SPARE _.-...............: ............................ ..................... .. ...... - 51 52 -- -- SPARE ; P qR. 20 3 - 53 C 54 - ,__...,.,.LOAD TYPE ...._-.. KVA S?ARE DATE ai 05/02/2016 20 3 55 A 56 3 20 SPARE. CM DATE 06/06/2016 - - 57 B 58 - - ----- - Y/ 120; P 3 W: 4 MOUNT ❑X SURFACE a FLUSH _...... _. _... FED FROM: FEED THRU - 59 G 60 CKT ................ BKR SPARE:! qR ........... # P H CIR # 20 3 61 A 62 3 20 SPARE - i i 277 - 63 B C 64 - - AIC RATING; 165.000 - 65 66 - --- SPARE STYLE ---NEUTRAL:J100°ti 3 2O 3 67 A 68 3 20 SPARE _----- FED FROM ._;FEEDTHRU-- ................... .. ..: - - 69 B 70 - - - 20 _.-...............: ............................ ..................... .. ...... 71 C 72 - - SPARE ; P qR. 20 3 73A LOAD- 74 3 20 SPARE SPARE ,__...,.,.LOAD TYPE ...._-.. KVA BKR.......... - 75 ......... B 76 - - - .KVA...._. TYPE............................. • ..:.-CIRCNTDESCPoP'nCN.; .......... ................ .. ........ WATER TANK PUMP #1 OHP - 77 A B 85 - SPARE 1 3 20 3 79 8D 3 20 SPARE 1 MTR 10.1287 -- 81 82 ---- 88 - - 11.09 - 83 G 84 - - 89 C A B 90 SPARE - 11,09 MTR WATER TANK PUMP #2 (_5HP) - -T ESTIMATED. MAXIMUM DEMAND (EMO) CALCULATIONS 50 3 91 92 3 50 .......... .. .. . ......... ..... .... ........ ....... LOAD SUMMARY LOADTYPE CONNECTED EM.D. CALCULATED MTR CRANE #2 (t TON) .... ...... ..... _.... ..... . CONNECTED PHASE LOADING LIGHTING LTG 4 00 KVA 0.00.! KVA (125%) .... ._.... } ... _..._ _ ... .. ..... RESIDENTLTG/RECPT .RES ........... I 000 ;KVA f . 0.00 IKVA (100135125 %) ................ 18 1 .......... ..........._... ........__. ............ ... _... PHASE A" 5D.51 KVA SMALLAPPLIANCE RES 0.00 KVA 0.00 KVA (100t38/25 %) - 20 95 PHASE B: 50.61 KVA LARGESTMOTORd00:KVA ........ .... .........._...... .. ...:... ... .. F 0.00 i KVA (125%) 8.31 MTR WATER TANK PUMP #3(iSHP) PHASE C: 5051:KVA REMAINING MOTORS MTR .. 13259 KVA .. 13259 IKVA (100%) .... A 98 3 ........ . ... ............... ............... ... ................ GENPURPOSE RECPT REC 000 KVA OM ,KVA (50%> 10KVA) - COMPUTERRECPT MISC 000 'KVA O00 KVA 100°/a (.. } - 99: GENERALNOTES:- EQUIP/OTHER MISC ............ _. .. - ... ........... .( _ .. tv95C x 20 .. .......... _........... .......... ....: ..._ MTR 5.27 „4..,.., _OOO:;KVA OOO.KVA(100%) 101 C 102 T�iUSTBEPROVIDEDWITHAMEANSTHAT WILLSFAULTANEOUSLYDISGONNECFALLUNGROUNDED LLL.. ELEVATOR,LLL ELEV 4 00 !KVA _ _ 0.01D.. KVA (8 :100°° _ ,_ _ 1 20 :CONDUCTORS AT THE PONT OF ORIGIN CONTRACTORS CHOICE PROVIDE SEPARATE NEUTRALS KITCHEN EQPT KITCH _.__. d OO KVA 0 00 ;KVA ;65 % 104 3 20 FOR BREAKER AS INDICATED OR PROVIDE idULTIFOLE BREAKER FOR SHARED NEUTRAL .-_.... ..... _ TOTALS ....... {_.__.15t54:KVA 151.54 ;KVA . .... ..... ......... .... .. ........... FLAG NOTES" ........ ........_ ..... ........ 1 18227 'AMPS . ........ 182.27 :AMPS ............ - 1 ......... . ... .. ... ...< ........... ...... ........................... ....... ....... ... ... .......... ........... ......... _. LOAD TYPE NOTES: SPARE SPARE 107 C A B ......:. COMB"=COMBGVATTONLOAD TYPES . ... ON INDICATEDCIRCUfi_ ...;.. ........... ........... MISC I SPACE - - ......... .... . ... ............ ... .... "RES RESIDENTIAL LTGIRECPTOR SMALL APPLIANCE LOAD TA KENATiNOICATED DEMAND_ .... ..........._ 109 .... ...... .. ........ .... _ "MISC EQUIP, COMPUTER REC OR HTG LOAD ON INDICATED CIRCUiTAT 100W ............. SPACE .............. ............... ... ....,................... .............. ... ............ ....... ..... _ 1. t a, RECEIVED CI -Ty OF TUKWILA �wJEB 1 'E�',ii� p FjM•IT CENTER REV # DATE ai 05/02/2016 02 06/03/2016 DRAWN CM CHECKED CM DATE 06/06/2016 PANEL SCHEDULE PANEL SCHEDULE PANEL: Ll (SEC 2) AMP: Q©© MLO �X MCB ❑ TYPE:: EXISTING ❑ NEW O LOCATION: MACHINE SHOP _ STYLE, VOLTS:: 208: APC RATING: 65,000 NEUTRAL: 100% .. Y/ 120; P 3 W: 4 MOUNT ❑X SURFACE a FLUSH _...... _. _... FED FROM: FEED THRU - li...._.._ ... _ .. .,.. _ .. ..._. .. ......... CIRCUITDESCRIPTION ._....... __...... ......-.......... LOAD _.............. TYPE LOAD .... KVA CKT ................ BKR P..._ qR ........... # P H CIR # PANEL HI (SEC 3). LOCATION MACHINE ROOM LOAD- TYPE VOLTS 480 Yl i 277 P:3 W ;4 ..._. ... MLO ❑X MCB ❑ . ...... ...........:.. AIC RATING; 165.000 _. SPARE MOUNT:. SURFACE ❑ FLUSH TYPE:'- EXISTING NEW X µ ❑. ❑ STYLE ---NEUTRAL:J100°ti 3 1 20 - -- -_-- SPARE ------- - ---_ -- _----- FED FROM ._;FEEDTHRU-- ................... .. ..: ...... .._ ........._................< . ..: _ .......... , ...... ...... 1 20 _.-...............: ............................ ..................... .. ...... - .................................. ...._ ... LOAD: -- CKT P CIR P qR. P CKT LOAD- - LOAD ..__.. ...._.. gRCURDESCRIPTICN - SPARE ,__...,.,.LOAD TYPE ...._-.. KVA BKR.......... "y" F{ .a. ._ . _# ..... ._BKR... .KVA...._. TYPE............................. • ..:.-CIRCNTDESCPoP'nCN.; .......... ................ .. ........ WATER TANK PUMP #1 OHP MTR 10.12 50 3 85 A 86 3 50' 11,09 MTR CRANE#1 (6 -TO N - 1 MTR 10.1287 -- --- SPARE B 88 - - 11.09 MTR 13 A MTR 10.12 - - 89 C A B 90 SPARE - 11,09 MTR WATER TANK PUMP #2 (_5HP) - -T MTR 9.42 50 3 91 92 3 50 8.31 MTR CRANE #2 (t TON) -- - MTR 9.42 - 20 93 94 - 18 1 8.31 MTR _ SPARE --_- - MTR. 9.42 - 20 95 C 96 - - 8.31 MTR WATER TANK PUMP #3(iSHP) MTR 5.27 253 20 97 A 98 3 20 5.54 MISC COOLING TOWER; - SPARE MTR 5.27 - - 99: MB 100 - - 5.54 tv95C x 20 MTR 5.27 - SPARE 101 C 102 20 - 5.54 FISC SPACE 1 20 ----- -. _._...__ .-------- ........ 103A -- - SPARE 104 3 20 0.78 NISC MIXER SPACE SPARE: 105 B 106 - - 0.78 MISC SPACE SPARE SPARE 107 C A B 108 1 - 0.78 MISC I SPACE - - 20 109 110: 20 SPACE ( -- SPACE 34 1 20 111 112 SPARE SPACE SPACE 35 36 1 20 - 113 G 114' SPACE SPACE -- --:- - - A 38 1 715 A 116 SPARC SPARE SPACE SPACE 40 1 20 - 117 B 118 - - 20 ---- 1 SPACE SPACE ---- 42 1 - 20 119 C 120 SPACE - SPACE 121 A 122 SPACE I SPACE ----------------- ---- - --- - _- _ GENERAL NOTES. ... - ..... ...... __....... ... _........... .. ........... 1 PER NEC 21DA(A) & (B)ALL h1ULTWIRE BRANCH CIRCUITS SHARING A CO MPAO 14 NEUTRAL WfftE MUST BEPROL EDWITHAMEANSTHATWILLS;MULTANEOUSLYDISCONNECT AL UNGROUNDED THE PONTOF ORDPC ONTRACR'S CHOICE PROVIDE SEPAR ATE FEUTRdS FOR BREAKER AS NIDI PR BEAKER FOR SHARED NEUTRAL. CATED OR PROVIDE MULTIPOLE....8 FLAG NOTES: 1 _ , .... ... ........... __ 123 B 124 -. SPACE ) SPACE --- 125 C 126' - =--- ---------- SPACE ESTIMATED MAXIMUM DEMAND (EMD) CALCULATIONS. _............... _.._...... ...__.... ---.:_ ..__.:.. ......... -.:...._.__. t t .........._ LOADS ----- : ;LOAD TYRE _ .. _... ...; : ---- CONPIECTED. --:.:._... EM.E):'CA LCEILATED :.......... --- - - ` - - ._ ` ;. _...... .._...._ .........-..... .. LIGHTING : LTG ------------- 0.00 ' KVA 0.00 KVA (125%) ._____._. x . ............... ... ....._. .. ..... .. CONNECTED PHASE LOADING RESIDENT LTG/RECPT RES _._... 01.0.011.1 KVA __._... . O 00 KVA (100f35R5 PHASE A_ 50.51 KVA ............ SMALL APPLIANCE . RES 0.00 KVA 0.00 KVA ( 10013525 %) ..... ......_..._ ........ _........ _... _ ......_.. __... PHASE B: 50.51 KVA LARGEST MOTOR 33.26 KVA 41.57, KVA (125%) i PHASE C 50.51 KVA _. REMAININGMOTORS MTR 9934 KVA 9934;KVA(100% GEN PURPOSE RECPT REC 0.00 KVA DOD KVA ( 50%> 1OKVA) COMPUTER RECPT MiSC 000 KVA DOD KVA (100%) GENERAL NOTES- EQUIP/OTHER MISC .. 18.95 KVA 18,95 KVA (100%) _ 1 PER NEC 2104(A)& (B)ALLMULTMNIRE BRANCH CIR CU ITS SHARNGACOMM!ON NEUTRAL WIRE HEATING MISC 0.00 KVA 0.00'KVA(100°k) MST BEPROVDED4V(THAPEANSTHAFWtILSIPAILTAPIEOUSLYDISGONNECFALLUNGROUNDED ELEVATOR ELEV 0.00 I KVA 0.00 : KVA 0' ;100% _ : _ -_ CONDUCTORS AT THE POINT OF ORIGIN. CONTRACTOR'S CHOICE: PROVIDE SEPARATE NEUTRALS ... _ - .. ---- _,, __- E -- --- _ ______ _ _, .__ _ ...... - ._.... _ _...- ..._.... -- - .... - -- - --- - - - - .... TOTALS _._ - ' -.....-- 15154 KVA _ __ - -- -- ---- 15985 'KVA _ - ---- - - FLAG NOTES .._... --- - - - -... _ . ..._._ ......_.-.._ - . 18227 AMPS 19227 -AMPS 1 - - -- LOAD TYFE NOTES COMB COMBINATION LOAD TYPES ON INDICATED CIRCUIT __._ -i "RES RESIDENTiALLTGIRECPTORSMALLAPPUANCE LOAD TAKEN AT INDICATED DEMAND _. _ _ ._ _.._.... .. EQUF, COMPUTER REC OR HTG LCW D ON INDICATED CffRCUiTAT 100%' - # - j 1. t a, RECEIVED CI -Ty OF TUKWILA �wJEB 1 'E�',ii� p FjM•IT CENTER REV # DATE ai 05/02/2016 02 06/03/2016 DRAWN CM CHECKED CM DATE 06/06/2016 PANEL SCHEDULE PANEL: Ll (SEC 2) AMP: Q©© MLO �X MCB ❑ TYPE:: EXISTING ❑ NEW O LOCATION: MACHINE SHOP _ STYLE, VOLTS:: 208: APC RATING: 65,000 NEUTRAL: 100% .. Y/ 120; P 3 W: 4 MOUNT ❑X SURFACE a FLUSH _...... _. _... FED FROM: FEED THRU - li...._.._ ... _ .. .,.. _ .. ..._. .. ......... CIRCUITDESCRIPTION ._....... __...... ......-.......... LOAD _.............. TYPE LOAD .... KVA CKT ................ BKR P..._ qR ........... # P H CIR # P CKT BKR LOAD KVA LOAD- TYPE _ gRCUTDESCRIPTION: SPARE 20 1 1 1 20 SPARE SPARE 20 1 3 1 20 - -- -_-- SPARE ------- - ---_ -- SPARE 20 1 5 1 20 SPARE SPARE 20 1 7 LB4 1 20 SPARE SPARE 20 1 9 1 20 SPARE SPARE20 1 11 1 20 -- --- SPARE SPARE 20' 1 13 A 14 1 20 SPARE SPARE 20 1 15 B C A 16 1 20 SPARE SPARE 20 1 17 18 1 24 _ SPARE --_- - SPARE 20 1 19 20 1 20 SPARE SPARE 20 121 B 22 1 20 SPARE SPARE 20 1 23 . C. 24 1 20 SPARE SPARE 20 1 25 ..... A B ^ <6 1 20 ----- -. _._...__ .-------- ........ - - - -- -------------- --- --- - - - - ------------ SPARE ___ ____ ---___ .----.._ SPARE -- - SPARE - 20 -- 1 27 - 28 1 _. 20 SPARE: 20 1 29 C 30 1 20 SPARE SPARE 20 1 31 A C 32 1 20 SPARE SPARE 20 1 33B 34 1 20 SPARE SPARE 20 1 35 36 1 20 - -- SPARE -- --- -- -- - SPARE 20 1L41 A 38 1 20 SPARC SPARE 20 1B 40 1 20 - - SPARE - -- ---------- -- - SPARE - SPARE - - 20 ---- 1 C ---- 42 1 - 20 ESTIMATED MAXIMUM DEMAND (EMD) CALCULATIONS LOAD SUMMARY: : LOADTYPE: CONNECTED EM.0. CALCULAT® - - CONNECTED PHASE LOADING.y-µy- UGHTiNG -.._ LTG 0.00 KVA - 0.00 KVA (125% RESIDENT LTG/RECPT - RE . .. ....... _{. ) SMALLAPPLIANCE RES 0.00 KVA 0.00 KVA (100135125 %) LARGESTMOTOR 0.00 .KVA 0.00 KVA 125°k _ _,- _ __. _{ REMAINING MOTORS MTR 0.0 0.00 V(100%) 0 ,KVA- KVA GEN PURPOSE RECPTREC 0.00 KVA 0.00 KVA (50%> ICKVA) RECPT. .- .... ... _....-._. COMPUTER RECPT MISC 0.00 KVA 0.00 'KVA (100°0) - ....... ...._...-......... ....... ......... EQUIP/OTHER M(SC 0-00 KVA 0.00 KVA 000%) HEATING FllSC O.DO KVA 0.001. KVA 100% ELEVATOR _ELEV 0-00 K A 0.00 KVA OC KITCHEN E PT KITCH 4. Q 00 A 0.00 KVA 65% KV TOTALS: 0.00 KVA 0,00 ;KVA D 00 AMPS 0 00 AMPS .... ... ............... ............................. __........ _.......... ...._ ............ . ._ ' LOAD TYPE NOTES: _. ._,. _._. . ..... ............... ...... ................... .......... ...... ... ... _...._......... "COMB 4COh181NAT10N LOAD TYPES ON INDICATED CIRCULI" RES = RESIDENTIAL LTG/RECPT OR SMALL A PP D CLANGS LOAD TAKENATIN ICATEO DEMAND "MISC" = EQUIP. COMPUTER REC OR HTG LOAD ON INDICATED CIRCUITAT100% _ -- PHASEA: O.00 KVA PHASE B. 0.00 KVA PHASE C: 0.00 KVA ___ ... _ .............. ,_,..�: _ GENERAL NOTES. ... - ..... ...... __....... ... _........... .. ........... 1 PER NEC 21DA(A) & (B)ALL h1ULTWIRE BRANCH CIRCUITS SHARING A CO MPAO 14 NEUTRAL WfftE MUST BEPROL EDWITHAMEANSTHATWILLS;MULTANEOUSLYDISCONNECT AL UNGROUNDED THE PONTOF ORDPC ONTRACR'S CHOICE PROVIDE SEPAR ATE FEUTRdS FOR BREAKER AS NIDI PR BEAKER FOR SHARED NEUTRAL. CATED OR PROVIDE MULTIPOLE....8 FLAG NOTES: 1 _ , .... ... ........... 1. t a, RECEIVED CI -Ty OF TUKWILA �wJEB 1 'E�',ii� p FjM•IT CENTER REV # DATE ai 05/02/2016 02 06/03/2016 DRAWN CM CHECKED CM DATE 06/06/2016 PANEL SCHEDULES L a N 0 0 0 s W 0 Q 0 0 W CD z 0 z W CL i U W O ix a N W 5-1 H CIRCUITING SYMBOLS POWER SYMBOLS DUPLEX RECEPTACLE 120V DOUBLE DUPLEX RECEPTACLE 120V / DUPLEX / QUAD RECEPTACLE - EMERGENCY POWER 6 DUPLEX RECEPTACLE - GROUND FAULT CIRCUIT INTERRUPTER TYPE DUPLEX RECEPTACLE - GROUND FAULT CIRCUIT INTERRUPTER TYPE, STANDBY POWER DOUBLE DUPLEX RECEPTACLE - GROUND FAULT CIRCUIT INTERRUPTER TYPE / DEDICATED DUPLEX / QUAD RECEPTACLE S DUPLEX RECEPTACLE - SAFETY TYPE DUPLEX RECEPTACLE - ABOVE COUNTER: MOUNT +6" ABOVE COUNTER/SINK/ BACKSPLASH OR MOUNT +54" AFF AS APPLICABLE GFI DUPLEX RECEPTACLE - ABOVE COUNTER: MOUNT +6" ABOVE COUNTER/SINK/ BACKSPLASH OR MOUNT +54" AFF AS APPLICABLE SPECIAL RECEPTACLE, NEMA/VOLTAGE AS INDICATED ON PLAN - ATTACH TO DROP CORD FROM CEILING SINGLE RECEPTACLE 120V TRIPLE RECEPTACLE SPLIT SWITCHED DUPLEX RECEPTACLE FLUSH FLOOR BOX WITH DEVICE AS INDICATED ® FLUSH MOUNTED CEILING RECEPTACLE PEDESTAL TYPE FLOOR BOX WITH DEVICES AS SHOWN 0@& FLUSH FLOOR POKE THROUGH - DEVICES AS INDICATED �1 SPECIAL RECEPTACLE, NEMA/VOLTAGE AS INDICATED SPECIAL RECEPTACLE, NEMA/VOLTAGE AS INDICATED ® DRYER RECEPTACLE ❑' DISCONNECT SWITCH ❑' FUSED DISCONNECT ® MOTOR STARTER EP COMBINATION MOTOR STARTER, DISCONNECT MOTOR CONNECTION MOTOR, THREE PHASE ® EQUIPMENT CONNECTION (� CLOCK HANGER AND OUTLET ON CRITICAL BRANCH CIRCUIT © CONTACTOR M MOTOR RATED SWITCH FRAO GENERATOR REMOTE ANNUNCIATOR PANEL / PANEL - 208/120 VOLT SYSTEM, +6' TO TOP U.N.O. ® PANEL - 480 VOLT SYSTEM, +6' TO TOP U.N.O. SIGNAL & COMMUNICATION SYMBOLS I] MAGNETIC DOOR HOLD -OPEN. INTERNAL TO CLOSER HARDWARE WHERE SHOWN AT HINGE. 0 FIRE ALARM MANUAL STATION +48" SMOKE DETECTOR "D" SUBSCRIPT INDICATES DUCT DETECTOR "H" SUBSCRIPT INDICATES HEAT DETECTOR "R" SUBSCRIPT INDICATES 120V RESIDENCE DEVICE WITH AUDIBLE TONE ALARM, BATTERY BACK-UP DO COMBINATION SPEAKERS/STROBE, WALL MOUNTED AT +80" R UNLESS NOTED OTHERWISE "R" SUBSCRIPT INDICATES AUDIBLE ALARM FOR RESIDENCE UNIT WIRED TO ACCOMODATE UPGRADE TO ALARM/STROBE. DO COMBINATION HORN/STROBE, CEILING MOUNTED >D FIRE ALARM STROBE ONLY, WALL MOUNTED AT +80" >OF FIRE ALARM STROBE ONLY, CEILING MOUNTED 60 FIRE ALARM REMOTE INDICATOR LIGHT CEI FIRE ALARM BELL/CHIME FACE FIRE ALARM CONTROL PANEL W Do. TELEPHONE OUTLET: "W" INDICATES WALL PHONE AT +54" D DATA OUTLET ® COMBINATION TELE/DATA OUTLET 0 COMBINATION FIRE/SMOKE DAMPER CONNECTION Q MOTORIZED DAMPER - 120V ® MMC MAGNETIC CONTACTS FOR WINDOW OR DOOR MONITORING PEDESTAL TYPE FLOOR BOX WITH DEVICE TYPE AS SHOWN —0-0- CABLE RING ROUTE & ELECTRIC CLOCK ED TV COAXIAL CONNECTION OO CEILING MOUNTED SPEAKER WALL MOUNTED SPEAKER 10 MICROPHONE oTR TELEPHONE RISER ® FLOOR CORE FOR VOICE/DATA ONLY oR CARD READER Full AUDIBLE DOOR ALARM EH VOLUME CONTROL AT +54" C -i EMERGENCY POWER OFF BUTTON LIGHTING SYMBOLS xx EM NEW WIRING. HASH MARKS INDICATE NUMBER OF #12 AWG WIRE 0 UNLESS NOTED OTHERWISE, NO HASH MARKS INDICATES a TWO WIRES PLUS GROUND UNLESS NOTED OTHERWISE. LONG HASH Q MARKS DENOTES NEUTRAL �- INDICATES GROUND WIRE. �-- INDICATES ISOLATED GROUND WIRE, WHERE SHOWN. AWG NEW WIRING RUN IN OR BELOW SLAB OR BELOW GRADE. - - - - - - - EXISTING RACEWAY OR WIRING (IF HASH MARKS ARE SHOWN xx M_*1 PULL NEW CONDUCTORS) 3 RACEWAY STUB -OUT WITH BUSHING —► HOME RUN TO PANEL OR LOCATION NOTED --� CIRCUIT CONTINUATION (E) JUNCTION BOX, CEILING/WALL ED PULL BOX HH HANDHOLE ----Po r/c---- UNDERGROUND UTILITY SERVICE - O POWER, TELEPHONE & CABLE AS INDICATED P/%/c OVERHEAD UTILITY SERVICE - FI POWER, TELEPHONE & CABLE AS INDICATED (__0 POWER POLE/GUY �-- G ---2 GROUND WIRE Aft IRREVERSIBLE COMPRESSION TYPE CONNECTION HT CADWELD TYPE GROUND CONNECTION ® GROUND TEST WELL ® GROUND ROD POWER SYMBOLS DUPLEX RECEPTACLE 120V DOUBLE DUPLEX RECEPTACLE 120V / DUPLEX / QUAD RECEPTACLE - EMERGENCY POWER 6 DUPLEX RECEPTACLE - GROUND FAULT CIRCUIT INTERRUPTER TYPE DUPLEX RECEPTACLE - GROUND FAULT CIRCUIT INTERRUPTER TYPE, STANDBY POWER DOUBLE DUPLEX RECEPTACLE - GROUND FAULT CIRCUIT INTERRUPTER TYPE / DEDICATED DUPLEX / QUAD RECEPTACLE S DUPLEX RECEPTACLE - SAFETY TYPE DUPLEX RECEPTACLE - ABOVE COUNTER: MOUNT +6" ABOVE COUNTER/SINK/ BACKSPLASH OR MOUNT +54" AFF AS APPLICABLE GFI DUPLEX RECEPTACLE - ABOVE COUNTER: MOUNT +6" ABOVE COUNTER/SINK/ BACKSPLASH OR MOUNT +54" AFF AS APPLICABLE SPECIAL RECEPTACLE, NEMA/VOLTAGE AS INDICATED ON PLAN - ATTACH TO DROP CORD FROM CEILING SINGLE RECEPTACLE 120V TRIPLE RECEPTACLE SPLIT SWITCHED DUPLEX RECEPTACLE FLUSH FLOOR BOX WITH DEVICE AS INDICATED ® FLUSH MOUNTED CEILING RECEPTACLE PEDESTAL TYPE FLOOR BOX WITH DEVICES AS SHOWN 0@& FLUSH FLOOR POKE THROUGH - DEVICES AS INDICATED �1 SPECIAL RECEPTACLE, NEMA/VOLTAGE AS INDICATED SPECIAL RECEPTACLE, NEMA/VOLTAGE AS INDICATED ® DRYER RECEPTACLE ❑' DISCONNECT SWITCH ❑' FUSED DISCONNECT ® MOTOR STARTER EP COMBINATION MOTOR STARTER, DISCONNECT MOTOR CONNECTION MOTOR, THREE PHASE ® EQUIPMENT CONNECTION (� CLOCK HANGER AND OUTLET ON CRITICAL BRANCH CIRCUIT © CONTACTOR M MOTOR RATED SWITCH FRAO GENERATOR REMOTE ANNUNCIATOR PANEL / PANEL - 208/120 VOLT SYSTEM, +6' TO TOP U.N.O. ® PANEL - 480 VOLT SYSTEM, +6' TO TOP U.N.O. SIGNAL & COMMUNICATION SYMBOLS I] MAGNETIC DOOR HOLD -OPEN. INTERNAL TO CLOSER HARDWARE WHERE SHOWN AT HINGE. 0 FIRE ALARM MANUAL STATION +48" SMOKE DETECTOR "D" SUBSCRIPT INDICATES DUCT DETECTOR "H" SUBSCRIPT INDICATES HEAT DETECTOR "R" SUBSCRIPT INDICATES 120V RESIDENCE DEVICE WITH AUDIBLE TONE ALARM, BATTERY BACK-UP DO COMBINATION SPEAKERS/STROBE, WALL MOUNTED AT +80" R UNLESS NOTED OTHERWISE "R" SUBSCRIPT INDICATES AUDIBLE ALARM FOR RESIDENCE UNIT WIRED TO ACCOMODATE UPGRADE TO ALARM/STROBE. DO COMBINATION HORN/STROBE, CEILING MOUNTED >D FIRE ALARM STROBE ONLY, WALL MOUNTED AT +80" >OF FIRE ALARM STROBE ONLY, CEILING MOUNTED 60 FIRE ALARM REMOTE INDICATOR LIGHT CEI FIRE ALARM BELL/CHIME FACE FIRE ALARM CONTROL PANEL W Do. TELEPHONE OUTLET: "W" INDICATES WALL PHONE AT +54" D DATA OUTLET ® COMBINATION TELE/DATA OUTLET 0 COMBINATION FIRE/SMOKE DAMPER CONNECTION Q MOTORIZED DAMPER - 120V ® MMC MAGNETIC CONTACTS FOR WINDOW OR DOOR MONITORING PEDESTAL TYPE FLOOR BOX WITH DEVICE TYPE AS SHOWN —0-0- CABLE RING ROUTE & ELECTRIC CLOCK ED TV COAXIAL CONNECTION OO CEILING MOUNTED SPEAKER WALL MOUNTED SPEAKER 10 MICROPHONE oTR TELEPHONE RISER ® FLOOR CORE FOR VOICE/DATA ONLY oR CARD READER Full AUDIBLE DOOR ALARM EH VOLUME CONTROL AT +54" C -i EMERGENCY POWER OFF BUTTON LIGHTING SYMBOLS xx EM FLUORESCENT FIXTURE, TYPE AS INDICATED ON PLAN 0 "XX" INDICATES FIXTURE TYPE, "EM" INDICATES EMERGENCY OPERATION a FLUORESCENT STRIP FIXTURE, DRAWN TO SCALE Q FIXTURE CEILING MOUNTED &I FIXTURE WALL MOUNTED EM FULL -SHADED FIXTURES SHALL BE CONNECTED TO EMERGENCY POWER "EM" AWG SERVICE PANEL, INDICATES EMERGENCY OPERATION 0-0 POLE MOUNTED EXTERIOR LIGHT FIXTURE xx M_*1 BATTERY PACK EMERGENCY LIGHTING UNIT ® BATTERY POWERED EXIT SIGN - ARROWS AS INDICATED, SHADING DED INDICATES SIDE(S) ILLUMINATED. 1 BATTERY POWERED EXIT SIGN WITH INTEGRAL EMERGENCY LIGHTS, (E) ARROWS AS INDICATED X X SINGLE POLE SWITCH (LETTER INDICATES SWITCH LEG) $os OCCUPANCY SENSOR WALL SWITCH 3 3 WAY SWITCH O INCANDESCENT DIMMER/SWITCH bF FLUORESCENT DIMMER/SWITCH FI DAYLIGHT SENSOR, # INDICATES CONTROLLED CIRCUIT DESIGNATION os CEILING OCCUPANCY SENSOR Ec PHOTO -CELL SWITCH MOUNTED UNDER SOFFIT, ORIENT NORTH ro TIMECLOCK HT FIXTURE PENDANT MOUNTED o WALL SCONCE �o SURFACE MOUNT 2X4 IH TRACK LIGHTING RISER SYMBOLS TRANSFER .SWITCH CIRCUIT BREAKER -<< %>- DRAW OUT CIRCUIT BREAKER OFEEDER DESIGNATION ��-- FUSED SWITCH GROUND PMOL PANEL G GROUND FAULT CIRCUIT BREAKER TRANSFORMER CABLE TO BUS CONNECTION AVAILABLE SHORT CIRCUIT CURRENT 0-9 METER ABBREVIATIONS AC MISCELLANEOUS FLAG NOTE a REVISION SYMBOL ^� EXISTING EQUIPMENT OR DEVICE XXX REMOVE EXISTING ELECTRICAL EQUIPMENT xx-x EQUIPMENT IDENTIFIER AWG TYPICAL ROOM DETAIL REFERENCES: (BTS) XX - INDICATES DETAIL NUMBER xx M_*1 M - INDICATES THAT DETAIL IS MIRROR IMAGE OF REFERENCED LOCATION EY.Y EY.Y - INDICATES SHEET WHERE DETAIL IS FOUND DED - DIRECTION OF ARROW INDICATES PLAN ORIENTATION IN DW RELATION TO DETAIL (E) PROPERTY LINE X X FENCING ® CABLE TRAY Q INDICATES COMBINATION POWER/TELE/DATA POKE-THRU FLUSH O FURNITURE FEED JUNTION BOX. ABBREVIATIONS AC INDICATES ABOVE COUNTER MOUNTING AT +4" ABOVE BACKSPLASH OR +6" - ABOVE COUNTERS WITHOUT BACKSPLASH AFF ABOVE FINISHED FLOOR A, AMP AMPERE ATS AUTOMATIC TRANSFER SWITCH AWG AMERICAN WIRE GAGE (BTS) BASE TRANSFER STATION CB CIRCUIT BREAKER CKT CIRCUIT DED DEDICATED DW DISHWASHER' (E) EXISTING EPO EMERGENCY POWER OFF EWC ELECTRIC WATER COOLER FA FIRE ALARM . FBOIC FURNISHED BY OTHERS, INSTALLED BY CONTRACTOR FI FILM ILLUMINATOR G, GND GROUND GD GARBAGE DISPOSAL GFI, GFCI GROUND FAULT CIRCUIT INTERRUPTER HT HEIGHT HWT HOT WATER. TANK IGN IGNITION IH INSTA HOT J -BOX JUNCTION BOX MW MICROWAVE - COORDINATE MOUNTING HEIGHT N NEUTRAL P POLE PNL PANEL PROVIDE FURNISH AND INSTALL (R) RELOCATED (INDICATES EXISTING EQUIPMENT TO BE RE -INSTALLED AS SHOWN) RO RACEWAY ONLY REC RECEPTACLE REF REFRIGERATOR S SAFETY TYPE SWBD SWITCHBOARD TYP TYPICAL UC UNDERCABINET UNO UNLESS NOTED OTHERWISE V VOLT W WIRE OR WATT PHASE W/O WITHOUT WP WEATHERPROOF NOTE REGARDING DRAWINGS: THESE DRAWINGS ARE PROVIDED FOR YOUR USE RELATING EXCLUSIVELY TO THE PROJECT CONTAINED HEREIN. SEA -TAC ELECTRIC, INC. PROVIDES THESE DRAWINGS WITH THE FOLLOWING STIPULATIONS: THIS DOCUMENT, AND THE IDEAS AND DESIGNS INCORPORATED HEREIN, AS AN INSTRUMENT OF PROFESSIONAL SERVICE, IS THE PROPERTY OF SEA -TAC ELECTRIC, INC. AND IS NOT TO BE USED, IN WHOLE OR IN PART, FOR ANY OTHER PROJECT WITHOUT THE WRITTEN CONSENT OF SEA -TAC ELECTRIC, INC. THE DESIGNS CONTAINED HEREIN ARE PROTECTED BY THE RULES AND REGULATIONS OF U.S. COPYRIGHT LAWS. THESE DRAWINGS AND DOCUMENTS WERE COPIED FROM COMPUTER DATA CREATED AS A STEP IN THE PRODUCTION OF PHYSICAL DATA FOR THIS PROJECT. THERE MAY BE DISCREPANCIES BETWEEN THESE DOCUMENTS AND THE COMPUTER DATA. WHERE SUCH DISCREPANCIES EXIST, ONLY THE PHYSICAL DOCUMENTS AND DRAWINGS CAN BE RELIED ON TO REFLECT THE WORK OF SEA -TAC ELECTRIC, INC., WHO MAKES NO GUARANTEES OR WARRANTIES REGARDING THESE DOCUMENTS OR THE DATA THEREIN. IN ACCEPTING THESE DOCUMENTS, YOU ASSUME ALL LIABILITY FOR THE ACCURACY, UTILITY, OR SUITABILITY FOR ANY PURPOSE FOR ANY DATA THESE DRAWINGS CONTAIN. COPYRIGHT© 2015 GENERAL NOTES: NOTE: "CONTRACTOR' MEANS "ELECTRICAL CONTRACTOR" WHEN REFERENCED ANYWHERE IN THE ELECTRICAL CONSTRUCTION DOCUMENTS UNLESS WORK AND EQUIPMENT HAS BEEN COORDINATED BETWEEN THE ELECTRICAL AND GENERAL CONTRACTORS TO BE PROVIDED BY THE GENERAL CONTRACTOR. "NEEDED", "PROMIDE", AND "INSTALL" MEANS ALL ITEMS CALLED OUT IN THE CONTRACT DOCUMENTS AND ANY ADDITIONAL ITEMS NOT CALLED OUT BUT REQUIRED TO MAKE A COMPLETE AND OPERATIONAL SYSTEM. SCOPE: THE INTENT OF THE DRAWINGS IS TO PROVIDE A COMPLETE AND FULLY OPERATIONAL ELECTRICAL SYSTEM. THE ELECTRICAL CONTRACTOR SHALL FURNISH AND INSTALL ALL LABOR, MATERIAL AND EQUIPMENT NECESSARY TO COMPLETE THE ELECTRICAL WORK. PERMITS AND FEES: THE ELECTRICAL CONTRACTOR SHALL PROCURE AND PAY FOR ALL PERMITS, FEES AND INSPECTIONS NECESSARY TO COMPLETE THE ELECTRICAL SCOPE OF WORK PRIOR TO STARTING THE WORK. WARRANTY: THE ELECTRICAL CONTRACTOR SHALL UNCONDITIONALLY WARRANTY ALL WORK TO BE FREE OF DEFECTS IN MATERIAL AND WORKMANSHIP FOR A PERIOD OF ONE (1) YEAR FROM THE DATE OF FINAL ACCEPTANCE BY THE OWNER OR OWNER'S REPRESENTATIVE AND WILL REPAIR OR REPLACE ANY DEFECTIVE WORK PROMPTLY AND WITHOUT CHARGE AND RESTORE ANY OTHER EXISTING WORK DAMAGED IN THE COURSE OF REPAIRING DEFECTIVE MATERIALS AND WORKMANSHIP. COD ALL WORK IN ACCORDANCE WITH THE CURRENT NATIONAL ELECTRICAL CODE, STATES, CITY ELECTRICAL CODES, AND ALL OTHER APPLICABLE CODES INCLUDING ANY STATE OR LOCAL ENERGY CODES. ALL WORK SHALL ALSO BE IN COMPLIANCE WITH BUILDING OWNER'S CRITERIA. IN CASE OF CONFLICT BETWEEN THE DRAWINGS, SPECIFICATIONS, CODES, ORDINANCES, AND AUTHORITIES HAVING JURISDICTION, THE MOST STRINGENT STANDARD (IN THE OPINION OF THE ENGINEER) SHALL APPLY. THE EC SHALL SATISY CODE, AHJ, DRAWINGS, AND SPECIFICATIONS AS A MININUM STANDARD WITHOUT ANY EXTRA COST. STANDARDS: EQUIPMENT AND MATERIALS SHALL CONFORM WITH APPROPRIATE PROVISIONS OF NEC, WAC, ASTM, UL, ETL, NEMA, ANSI, AND OTHER APPLICABLE AGENCY AS THEY APPLY TO EACH INDIVIDUAL UNIT OR ASSEMBLY. COPYRIGHT© 2015 Ru COPY Pearmilt Ila. w(-ezw_ FN -t -A is wbiect t0 errors and �,_ ;�T•� ! rn; ,o� -r�--yy %'-z. '�q-a i�yK u .-drgnn T. •. �4--t p'. Y`.�. �t C;ii '.si .`.��'': �4i .., �..:+I Vii s.il_e..i�.�.' iP.�. 7 t6 Sea.....J � �� G,�...... e c;'��C✓ to to©i `s5i i 1 any addonee 'cod`s.+ or ordinanco.it 5- 'l Of p vo",d y'G1d Copy and co ion �. �i a i � _ �:,1 8 ::9a � i't:�:et3 �:7 is . Date:Jr _. City OT s L icwila BUILDING DIVISION REVISIONS No changes shall be made to the, scope Of work without prior approval of TukErila Building Division. t,'OTS: `iib" 11s will require a nevoi plan submittal and nay ir,z'udo ad>s"tianai p!an reviewfeeS � t 2E:CEIVED CIT 5 OF-�UWILA 5y �12, 2,�5 PERMIT CENTER 1 1SYMBOLS EO.02 - ELECTRICAL NOTES 1 E. PLAN E5.01 ONE- j V Ile z - 1`< .i - •i .i CL D LU -- • L0 z 0 qtj- < r%kft 0-5 0� S! °%F1-�i E I`E2�i -i'diIT R=Q U' L]: D X011: ,0t4c"chanicai ❑ Efe=-icaf ,01Plumbing OGas Piping CiV, Of TUkiufla DIVISION REV # DATE DRAWN CM CHECKED CM DATE 04/08/2016 SYMBOLS & ABBREVIATIONS 9 0 I m C. N O s 0 0 0 a 0 in CL W .Z 0 Z W C_ U O C. C7 W PLAN SPECIFIC GENERAL NOTES: THE FOLLOWING GENERAL NOTES APPLY TO ALL DRAWINGS 1 • ITEMS NOTED AS "TYPICAL" ON ANY DRAWING REFERS TO ALL DRAWINGS. 2. PROVIDE NYLON PULL STRING IN ALL EMPTY RACEWAYS. 3. NO STRUCTURAL MEMBERS SHALL BE CUT OR ALTERED WITHOUT PRIOR APPROVAL OF THE ARCHITECT AND STRUCTURAL ENGINEER. 4. LOCATIONS OF ALL MOUNTED DEVICES ARE SHOWN SCHEMATICALLY. COORDINATE WITH THE ARCHITECTURAL DRAWINGS, ELEVATIONS AND CASEWORK SUPPLIERS SHOP DRAWINGS FOR EXACT LOCATION OF DEVICES PRIOR TO ROUGH IN. 5. RACEWAYS IN FINISHED SPACES SHALL BE CONCEALED. 6. PROVIDE 2" EMT SLEEVES FOR LOW VOLTAGE WRING RUNNING THROUGH NON -RATED WALLS, FLOORS AND CEILINGS. 7. PROVIDE STI "EZ -PATH" ASSEMBLIES AT EACH LOCATION WHERE LOW VOLTAGE WIRING PENETRATES A RATED WALL OR CEILING. ASSUME 50 ARE TO BE PROVIDED. 8. SEAL PENETRATIONS IN RATED FLOORS AND CEILINGS WITH A UL APPROVED FIRE STOP SYSTEM. 9• PROVIDE A COMPLETE DESIGN -BUILD PATHWAY SYSTEM FOR ALL POWER & SPECIAL SYSTEMS WIRING, SEE SPECIFICATIONS. QUANTITY AND SIZE OF RACEWAYS SHOWN ON POWER & SPECIAL SYSTEMS PLANS ARE THE MINIMUM TO BE PROVIDED. CONTRACTOR SHALL PROVIDE ALL RACEWAYS AS REQUIRED. 10. LOW VOLTAGE WIRING NOT RUN IN A METALLIC RACEWAY SHALL BE PLENUM RATED. 11. EQUIPMENT, LUMINAIRES, RACEWAYS, DEVICES, ETC. SHALL BE UL LISTED. 12. MOUNT DEVICES ABOVE COUNTERS 6" ABOVE BACKSPLASH UNLESS NOTED OTHERWISE, 13. WHERE A CONFLICT EXISTS THE MOST EXPENSIVE OPTION SHALL GOVERN. 14. PROVIDE RACEWAYS AND WIRING REQUIRED TO INSTALL ELECTRONIC DOOR HARDWARE. REFER TO DOOR HARDWARE SPECIFICATION, SCHEDULES AND DIAGRAMS. EQUIPMENT CONNECTIONS 1. VERIFY ELECTRICAL REQUIREMENTS WITH MANUFACTURER SHOP DRAWINGS PRIOR TO ROUGH -IN. 2. INSTALL AND WIRE EQUIPMENT PER MANUFACTURER SHOP DRAWING. 3. PROVIDE ALL RACEWAYS, WIRING ONLY AS SHOWN ON MANUFACTURER SHOP DRAWINGS. 4. PROVIDE HARDWIRED CONNECTION, RECEPTACLE OR FUSED DISCONNECT SWITCH ON MANUFACTURER SHOP DRAWINGS. POWER & SPECIAL SYSTEMS PLANS 1. CIRCUIT ALL FIRE/SMOKE DAMPERS AND SMOKE DAMPERS FROM NEAREST 120V EMERGENCY PANEL WITH r EMT CONDUIT, (3) #12 AWG. RECORD CIRCUITING ON AS -BUILT DRAWINGS. REFER TO MECHANICAL DRAWINGS FOR DAMPER LOCATIONS. 2. PRIOR TO ORDERING EQUIPMENT OR ROUGH -IN, COORDINATE WITH THE MECHANICAL CONTRACTOR TO ESTABLISH THE ACTUAL LOAD AND OVERCURRENT PROTEC11ON REQUIREMENTS FOR EACH PIECE OF EQUIPMENT. 3. REFER TO MECHANICAL EQUIPMENT CONNECTION SCHEDULE FOR EQUIPMENT RATINGS AND FEEDER SIZES. 4. PROVIDE DISCONNECT SWITCH OR COMBINATION STARTER FOR EACH PIECE OF EQUIPMENT AS SHOWN ON MECHANICAL EQUIPMENT CONNECTION SCHEDULE. 5. PRIOR TO ROUGH -IN OF ALL EQUIPMENT SPECIFIED BY OTHER DIVISIONS COORDINATE WITH THE EQUIPMENT MANUFACTURER TO ESTABLISH ALL REQUIREMENTS FOR EACH PIECE OF EQUIPMENT. 6. EXTERIOR RECEPTACLES SHALL BE WP/GFCI. 7. HOMERUNS OVER 100' SHALL BE #10 AWG MINIMUM. B. POWER AND SPECIAL SYSTEMS TO SHARE A COMMON FLOOR BOX. 9. FEEDER ROUTING SHOWN IS APPROXIMATE. COORDINATE WITH MECHANICAL SYSTEMS AND BUILDING STRUCTURE. PROVIDE OFFSETS AS REQUIRED. 10. RECEPTACLES WITHIN 6 FEET OF A SINK SHALL BE A GFCI TYPE. 11. MINIMUM RACEWAY SIZE SHALL BE r FOR ALL OTHER SYSTEMS. 12. POWER AND SPECIAL SYSTEMS WRING SHALL BE RUN UTILIZING OPEN WRING METHOD ABOVE ACCESSIBLE CEILINGS. PROVIDE METALLIC RACEWAYS FOR WIRING INSTALLED IN WALLS, ABOVE INACCESSIBLE CEILING, WHERE EXPOSED OR WHERE SUBJECT TO PHYSICAL DAMAGE. RACEWAY FILL SHALL NOT EXCEED 409'0. 13. PROVIDE FIRE ALARM CONNEC11ON TO FIRE SPRINKLER TAMPER, FLOW, AND PRESSURE SWITCHES. REFER TO MECHANICAL DRAWINGS FOR LOCATIONS. 14. PROVIDE r A -C FIRE RETARDANT PLYWOOD ON SERVER ROOM WALLS FORE TELE/DATA BACKBOARD. MOUNT 8' DIMENSION VERTICAL 15. STAPLES SHALL NOT BE USED TO SECURE LOW VOLTAGE CABLING. 16. CABLING NOT RUN IN A METALLIC RACEWAY SHALL BE PLENUM RATED. ONE LINE DIAGRAM 1. FEEDERS ARE ALUMINUM WITH THHN/THWN INSULATION. 2. PROVIDE PULL BOXES AS REQUIRED BY THE NEC. 3. SHORT CIRCUIT CURRENTS LESS THAN 10,000 AIC FOR 208V PANELS AND 14,000 AIC FOR 480V PANELS ARE NOT SHOWN. 4. THE ONE -LINE DIAGRAM IS DIAGRAMMATIC AND DOES NOT SHOW THE ACTUAL ROUTING OF RACEWAYS. 5. FOR TWO SECTION PANELS PROVIDE FULL SIZE FEEDER CONNECTIONS FROM SECTION 1 TO SECTION 2. 6. NOT ALL CIRCUIT BREAKERS ARE SHOWN, REFER TO PANEL AND SWITCHBOARD SCHEDULES FOR OTHER LOADS SERVED, AND SPARE CIRCUIT BREAKERS. BRANCH CIRCUIT WIRING THE FOLLOWING GENERAL NOTES APPLY TO ALL DRAWINGS 1. IN GENERAL ONLY CIRCUIT NUMBERS HAVE BEEN SHOWN ON THE DRAWINGS. THE CONTRACTOR SHALL PROVIDE ALL REQUIRED RACEWAYS AND WIRING. 2. SHOW RACEWAYS AND WIRING ON AS -BUILT DRAWINGS. 3. GENERAL - 3.1. MINIMUM RACEWAY SIZE SHALL BE r EMT 3.2. NO MORE THAN 6 #12 AWG CONDUCTORS SHALL BE INSTALLED IN A RACEWAY, 3.3. HOMERUNS GREATER THAN 100 FEET TO THE FIRST DEVICE SHALL BE #10 AWG. 3.4. LIGHTING, POWER AND MECHANICAL EQUIPMENT CONDUCTORS SHALL NOT BE COMBINED IN THE SAME RACEWAY. 3.5. PROVIDE A GROUND CONDUCTOR IN ALL RACEWAYS. 3.6. PROVIDE A DEDICATED NEUTRAL CONDUCTOR FOR EACH BRANCH CIRCUIT. BREAKER TIES OR MULTI -POLE BREAKERS MAY BE USED IN LIEU OF A DEDICATED NEUTRAL 4. LIGHTING: 4.1. PROVIDE CONDUCTORS AS REQUIRED TO PROVIDE CIRCUITING AND SWITCHING DUTY AS SHOWN ON THE DRAWINGS. 4.2. PROVIDE A DEDICATED NEUTRAL CONDUCTOR FOR EACH BRANCH CIRCUIT. BREAKER TIES OR MULTI -POLE BREAKERS MAY BE USED IN LIEU OF A DEDICATED NEUTRAL 5. POWER: 5.1. PROVIDE CONDUCTORS AS REQUIRED TO PROVIDE CIRCUITING SHOWN. 5.2. FOR OTHER THAN 15 OR 20 AMP SINGLE PHASE RECEPTACLE BRANCH CIRCUITS PROVIDE A DEDICATED HOMERUN TO THE PANEL 5.3. FOR 30 AMP BRANCH CIRCUITS PROVIDE #10 AWG CONDUCTORS. FOR 40 AMP AND LARGER BRANCH CIRCUITS PROVIDE RACEWAYS AND WIRING AS SHOWN ON THE DRAWINGS. 5.4. PROVIDE A DEDICATED NEUTRAL CONDUCTOR FOR EACH BRANCH CIRCUIT. BREAKER TIES OR MULTI -POLE BREAKERS MAY BE USED IN LIEU OF A DEDICATED NEUTRAL 6.. MECHANICAL EQUIPMENT. PROVIDE RACEWAYS AND WIRING AS SHOWN ON THE MECHANICAL EQUIPMENT CONNECTION SCHEDULE. GENERAL ELECTRICAL NOTES: 1. EC SHALL VERIFY THE LOCATION OF ALL EXISTING UTILITIES PRIOR TO CONSTRUCTION AND BE RESPONSIBLE FOR SITE INVESTIGATION PRIOR TO START OF WORK TO REVEAL THE FULL SCOPE OF WORK. IN ADDITION, THE EC SHALL THOROUGHLY EXAMINE ALL AREAS WHERE EQUIPMENT, CONDUIT, AND WIRING WILL BE INSTALLED AND WILL REPORT ANY CONDITION THAT PREVENTS THE PROPER INSTALLATION OF THE ELECTRICAL WORK. 2. EC SHALL COORDINATE WITH THE GC TO PATCH AND REPAIR ALL EXISTING WALLS, FLOORS, CEILINGS OR OTHER SURFACES IDENTIFIED TO REMAIN THAT MAY BECOME DAMAGED DURING THE COURSE OF WORK. 3. EXPOSED/SURFACE MOUNTED CONDUITS SHALL ONLY BE ALLOWED WHERE NECESSARY IN EXPOSED CEILING AREAS. IF CONDUITS NEED TO BE SURFACE MOUNTED TO WALLS, COORDINATE WITH OWNER OR OWNER'S REPRESENTATIVE FOR APPROVAL AND SEE SPECS FOR FURTHER INFORMATION. 4. VERIFY LOCATION OF ALL OUTLETS AND SWITCHES WITH ARCHITECTURAL DRAWINGS, INTERIOR DETAILS, FINISH SCHEDULES, GENERAL CONTRACTOR, EQUIPMENT VENDORS, OWNER OR OWNER'S REPRESENTATIVE AND EXISTING SITE CONDITIONS. VERIFY FINAL DOOR HINGE LOCATION PRIOR TO SWITCH INSTALLATION AND ADJUST SWITCH LOCATION IF NEEDED. DO NOT MOUNT RECEPTACLES/SWITCHES IN LOCATIONS THAT WOULD CONFLICT WITH MIRRORS, SEAMS OF WALLS, WAINSCOTS, TILE TRANSITIONS, ETC. 5. DRAWINGS ARE DIAGRAMMATIC AND INDICATE GENERAL INTENT OR ARRANGEMENT OF SYSTEM(S). FOLLOW DRAWINGS IN LAYING OUT WORK AND COORD. WITH OTHER TRADES TO VERIFY SPACE CONDITIONS AND CLEARANCES. MAINTAIN HEADROOM AND SPACE CONDITION. MAKE APPROPRIATE ADJUSTMENTS AT OWNER OR OWNER'S CONTRACTOR'S DIRECTION. 6. COORDINATE WITH OTHER TRADES FOR ANY NEEDED LOW VOLTAGE CONTROL WIRING AND DEVICES THAT IS NEEDED BUT MAY NOT BE SHOWN IN THESE DRAWINGS. 7. TEMPORARY POWER: REUSE EXISTING PANEL (IF IN GOOD CONDITION) AND SERVICE FOR TEMPORARY CONSTRUCTION POWER. ALL RECEPTACLES TO BE USED DURING CONSTRUC11ON SHALL BE GFI PROTECTED. 8. ALL ELECTRICAL SYSTEMS SHALL BE TESTED FOR PROPER OPERATION. BALANCE ALL BRANCH CIRCUITS LOADS BETWEEN THE PHASES OF THE SYSTEM TO WITHIN 10% OF THE HIGHEST PHASE LOAD IN EACH PANELBOARD. 9. THE EC SHALL SCHEDULE ALL ELECTRICAL SYSTEM(S) SHUTDOWNS WITH THE GENERAL CONTRACTOR AND LANDLORD AT LEAST 24 HOURS IN ADVANCE. UNLESS APPROVED OTHERWISE ALL SHUTDOWNS SHALL OCCUR BETWEEN 11:00PM AND 5:OOAM. NOTE:"CONTRACTOR" MEANS "ELECTRICAL CONTRACTOR" WHEN REFERENCED ANYWHERE IN THE ELECTRICAL CONSTRUC11ON DOCUMENTS UNLESS WORK AND EQUIPMENT HAS BEEN COORDINATED BETWEEN THE ELECTRICAL AND GENERAL CONTRACTORS TO BE PROVIDED BY THE GENERAL CONTRACTOR. "NEEDED", "PROVIDE", AND "INSTALL" MEANS ALL ITEMS CALLED OUT IN THE CONTRACT DOCUMENTS AND ANY ADDITIONAL ITEMS NOT CALLED OUT BUT REQUIRED TO MAKE A COMPLETE AND OPERATIONAL SYSTEM. SCOPE THE INTENT OF THE DRAWINGS IS TO PROVIDE A COMPLETE AND FULLY OPERATIONAL ELECTRICAL SYSTEM. THE ELECTRICAL CONTRACTOR SHALL FURNISH AND INSTALL ALL LABOR, MATERIAL AND EQUIPMENT NECESSARY TO COMPLETE THE ELECTRICAL WORK. PERMITS AND FEES THE ELECTRICAL CONTRACTOR SHALL PROCURE AND PAY FOR ALL PERMITS, FEES AND INSPECTIONS NECESSARY TO COMPLETE THE ELECTRICAL SCOPE OF WORK PRIOR TO STARTING THE WORK. WARRANTY THE ELECTRICAL CONTRACTOR SHALL UNCONDITIONALLY WARRANTY ALL WORK TO BE FREE OF DEFECTS IN MATERIAL AND WORKMANSHIP FOR A PERIOD OF ONE (1) YEAR FROM THE DATE OF FINAL ACCEPTANCE BY THE OWNER OR OWNER'S REPRESENTATIVE AND WILL REPAIR OR REPLACE ANY DEFECTIVE WORK PROMPTLY AND WITHOUT CHARGE AND RESTORE ANY OTHER EXISTING WORK DAMAGED IN THE COURSE OF REPAIRING DEFECTIVE MATERIALS AND WORKMANSHIP. CODES PERFORM ALL WORK IN ACCORDANCE WITH THE CURRENT NATIONAL ELECTRICAL CODE, STATES, CITY ELECTRICAL CODES, AND ALL OTHER APPLICABLE CODES INCLUDING ANY STATE OR LOCAL ENERGY CODES. ALL WORK SHALL ALSO BE IN COMPLIANCE WITH BUILDING OWNER'S CRITERIA. IN CASE OF CONFLICT BETWEEN THE DRAWINGS, SPECIFICATIONS, CODES, ORDINANCES, AND AUTHORITIES HAVING JURISDICTION, THE MOST STRINGENT STANDARD (IN THE OPINION OF THE ENGINEER) SHALL APPLY. THE EC SHALL SATISY CODE, AHJ, DRAWINGS, AND SPECIFICATIONS AS A MININUM STANDARD WITHOUT ANY EXTRA COST. STANDARDS EQUIPMENT AND MATERIALS SHALL CONFORM WITH APPROPRIATE PROVISIONS OF NEC, WAC, ASTM, UL, ETL, NEMA, ANSI, AND OTHER APPLICABLE AGENCY AS THEY APPLY TO EACH INDIVIDUAL UNIT OR ASSEMBLY. BASIC MATERIALS AND METHODS MATERIALS: PROVIDE ALL NEW MATERIAL AND EQUIPMENT UNLESS NOTED OTHERWISE. ALL EQUIPMENT SHALL BE UL APPROVED, LABELED, AND LISTED OR OTHER APPROVED TESTING ORGANIZATION WHICH HAS ACCEPTANCE BY THE AUTHORITIES HAVING JURISDICTION FOR THE PURPOSE FOR WHICH THEY ARE USED. IN ADDITION, MEETING ALL REQUIREMENTS OF THE CURRENT APPLICABLE CODES AND REGULATIONS. NO SUBSTITUTION OF MATERIALS SPECIFIED WILL BE ALLOWED UNLESS NOTED OTHERWISE. ALL ITEMS ARE NEW UNLESS OTHERVASE NOTED. CUTTING AND FITTING: PERFORM CUTTING, CORING, FITTING, REPAIRING AND FINISHING OF THE WORK NECESSARY FOR THE INSTALLATION OF THE EQUIPMENT. HOWEVER, NO CUTTING OF THE WORK OF OTHER TRADES OR OF ANY STRUCTURAL MEMBER SHALL BE DONE WITHOUT THE CONSENT OF THE ARCHITECT, CONSTRUCTION MANAGER, GC, AND/OR OWNER. PROPERLY FILL, SEAL, FIREPROOF, AND WATERPROOF ALL OPENINGS, SLEEVES AND HOLES IN SLABS, WALLS, AND CASEWORK. RACEWAYS co N Lo Lo PROVIDE CODE APPROVED WIRING METHODS FOR BRANCH CIRCUITING INDOORS, SUCH AS EMT 19 N N CONDUIT WITH COPPER CONDUCTORS OR MC CABLE (PROVIDED IT IS CONCEALED FROM VIEW � � AND NOT EXPOSED). ALL ABOVE GROUND CONDUITS SHALL BE EMT OR RIGID, MINIMUM 1/2" IN m co SIZE (LION). CONDUITS SHALL BE SIZED PER CODE AND AS NEEDED TO INSTALL CONDUCTORS. 0 CONDUIT CONNECTORS SHALL BE DOUBLE LOCKNUT TYPE, UL LISTED AND LABELED, WITH W COMPRESSION OR SET SCREW FITTINGS. PVC CONDUITS ARE NOT ALLOWED ABOVE SLAB o UNLESS CODE AND AHJ APPROVED/1.1STED FOR THAT USE. Z a CONDUIT RUNS ON EXTERIOR OF BUILDING SHALL BE CONCEALED AND BE RIGID STEEL C„ CONDUIT WITH WEATHER TIGHT, CORRISION-RESISTANT FITTINGS (OR PVC WHERE LISTED FOR EXTERIOR -SUNLIGHT USE). CONDUIT SHALL NOT BE RUN EXPOSED WITHOUT SPECIFIC PERMISSION FROM THE CONSTRUCTION MANAGER. w WHERE RACEWAYS ARE INSTALLED FOR OTHERS TO USE, OR FOR FUTURE USE, PROVIDE NYLON W PULL STRINGS END TO END WITH A LABEL ON BOTH ENDS STATING USE AND LOCATION OF= OTHER STUB (E.G. DATA -FRONT POS). W o N N O PENETRATIONS THROUGH FIRE RATED CONSTRUCTION SHALL BE SEALED USING 3M FIRE uj 0) BARRIER CAULK, NELSON ELECTRIC FLAMESEAL OR T&B FLAME SAFE OR OTHER METHOD o APPROVED THE ARCHITECT AND AHJ. c U z CONDUIT RUNS CONCEALED IN CONCRETE OR UNDERGROUND SHALL BE 3/4" MINIMUM, UNLESS Y OTHERWISE NOTED W/RIGID STEEL ELBOWS. CONDUIT CONNECTORS SHALL BE DOUBLE LOCKNUT TYPE, UL LISTED AND LABELED, WITH COMPRESSION OR SET SCREW FITTINGS. IF CONDUIT RACEWAYS CANNOT BE RECESSED IN WALLS DUE TO CONSTRUCTION OR EXISTING CONDITIONS, PROVIDE A STEEL SURFACE MOUNTED RACEWAY SYSTEM (WIREMOLD, HUBBEL OR APPROVED EQUAL) WITH ALL COMPATIBLE DEVICES. THIS TYPE OF SYSTEM IS ONLY ALLOWED WHERE APPROVED BY OWNER OR OWNER'S REPRESENTATIVE INCLUDING LAYOUT. CONFIRM COLOR AND ANY CUSTOM FINISHES WITH OWNER OR OWNER'S REPRESENTATIVE. CONDUCTORS AND TERMINATIONS CONDUCTORS: SHALL BE ALUMINUM, INSULATED FOR 60OV, TYPE THWN/THHN, NUMBER 12 AWG MIMIMUM UNO. MOTORS AND OTHER WIRING: THE ELECTRICAL CONTRACTOR SHALL PROVIDE ALL NEEDED CONDUIT, TIRING, CONNECTIONS, AND SAFETY SWITCHES FOR ALL MOTORS, AND EQUIPMENT, EVEN IF THE MOTORS AND EQUIPMENT ARE SUPPLIED BY OTHERS. MOTORS, CONTROLS, ETC. MAY BE FURNISHED BY THE SUPPLIER OF THE DRIVEN EQUIPMENT. THE ELECTRICAL CONTRACTOR SHALL INCLUDE ALL WORK AND CONNECTIONS NEEDED TO MAKE THE SYSTEM COMPLETE AND OPERATIONAL ALL ELECTRICAL CONNEC11ONS TO MECHANICAL EQUIPMENT SHALL BE DONE BY THE ELECTRICAL CONTRACTOR. THE ELECTRICAL CONTRACTOR SHALL VERIFY EQUIPMENT LOCATION AND SIZES WITH THE TRADE AND VENDOR SUPPLYING THE EQUIPMENT PRIOR TO ROUGH -IN. GROUNDING ALL MAJOR PARTS NOT CARRYING CURRENT, INCLUDING BUT NOT LIMITED TO, SECONDARY FEEDER CIRCUIT, EQUIPMENT AND PANELBOARD ENCLOSURES, PULL AND JUNCTION BOXES AND OTHERS DEFINED BY CODE, SHALL BE PROPERLY GROUNDED. METALLIC RACEWAYS SHALL UTILIZE DOUBLE LOCKNUTS AND OTHER FITTINGS TO PROVIDE GROUND CONTINUITY. SWITCHES AND RECEPTACLES SWITCHES: GRADE OR APPROVED EQUAL WITH DURABLE COVERPLATES. COORDINATE WITH OWNER OR OWNER'S REPRESENTATIVE DM FOR COVERPLATE TYPE (E.G. STAINLESS STEEL) AND FOR COLOR OF STITCH AND PLATE. RECEPTACLES: GRADE OR APPROVED EQUAL WITH DURABLE COVERPLATES. COORDINATE WITH OWNER OR OWNER'S REPRESENTATIVE DM FOR FOR COVERPLATE TYPE (E.G. STAINLESS STEEL) AND FOR COLOR OF RECEPTACLE AND PLATE. INSTALL RECEPTACLES PLUMB, LEVEL, AND SECURE TO J -BOX. PROVIDE GFCI TYPE WHERE INDICATED AND WHERE REQUIRED BY CODE AND AHJ. GFCI RECEPTACLES SHALL BE CLASS A RATED FOR PERSONNEL PROTECTION.ALL RECEPTACLES ARE TO BE MOUNTED 18" ABOVE FINISHED FLOOR TO CENTER OF DEVICE UNLESS NOTED OTHERWISE. OCCUPANCY SENSORS: SENSORSWITCH WSD SERIES FOR SINGLE OCCUPANT RESTROOMS AND CLOSETS AND SENSORSWITCH CONTRACTOR CHOSEN/OWNER APPROVED (PIR AND ULTRASONIC SOUND ACTIVATED) FOR PARTITIONED RESTROOMS. 0 LOW VOLTAGE ALL LOW VOLTAGE WORK SHALL COMPLY, BE PERMITTED AND INSPECTED PER STATE (AND 0 Q LAHJ) REQUIREMENTS. ALL LOW VOLTAGE WORK SHALL BE INSTALLED BY A LICENSED 00 L1.1 00 CONTRACTOR IN ACCORDANCE WITH THE STATE AND LAHJ REQUIREMENTS. ® 0T0 ALL LOW VOLTAGE CABLING INSTALLED UNDERGROUND SHALL BE ROUTED IN A CONDUIT RACEWAY AND CABLING/CONDUCTORS SHALL BE LISTED FOR USE IN WET LOCATIONS, FOR LOW C) Q VOLTAGE APPLICATION AND PER LAHJ. ALL LOW VOLTAGE CABLING ROUTED INDOORS SHALL BE ROUTED CONCEALED IN WALLS/CEILINGS IN A CONDUIT RACEWAY (UNLESS OWNER AND LAHJ AUTHORIZE IT TO BE W Q ROUTED EXPOSED THROUGH WALL/CEILING). IF APPROVED BY OWNER & LAHJ TO BE ROUTED > J EXPOSED, CABLING SHALL BE PROPERLY FASTENED/SUPPORTED PER CODE, LAHJ, AND O INDUSTRY STANDARDS. CABLING NOT ROUTED IN CONDUIT SHALL BE PLENUM RATED WHERE 0 REQUIRED BY CODE OR LAHJ (CONFIRM WHETHER CEILING SPACE IS BEING USED AS AN AIR z PLENUM.) '►1 r Q ALL LOW VOLTAGE CABLING OUTDOORSON ROOF SHALL BE ROUTED IN ® LO ~ (E.G.( ) CONDUIT PER CODE AND LAHJ REQUIREMENTS UNLESS SPECIFICALLY LISTED AND LABELED FOR EXTERIOR ® 0*) USE. d' PANELBOARDS PANELBOARDS SHALL HAVE PLUG-IN OR BOLT ON BREAKERS AND MAIN LUGS ONLY OR MAIN BREAKERS AS NEEDED OR REQUIRED. PANELBOARDS SHALL BE CONSTRUCTED WITH ALUMINUM BUS AND BE ENCLOSED IN NEMA 1 HOUSING (OR AS REQ'D BY CODE). ENCLOSURE(S) SHALL BE COMPLETE WITH A HINGED DOOR, CYLINDER LOCK, AND A NEATLY TYPED CIRCUIT BREAKER DIRECTORY UNDER PLASTIC COVER IN EACH PANEL ALL MULTIPLE POLE BREAKERS (AND OTHER BREAKERS REQ'D BY CODE) SHALL HAVE A COMMON TRIP HANDLE. FUSED SWITCHES FUSED SWITCHES: HEAVY DUTY TYPE, HORSE POWER RATED WITH INTERLOCKING COVER. NEMA 1 TYPICAL OUTDOORS AND WET LOCATION SWITCHES SHALL BE RAINTIGHT TYPE NEMA 3R. ALL SWITCHES SHALL BE LOCKABLE. FUSES IN CIRCUITS RATED AT 600A OR LESS SHALL BE UL CLASS RK1 DUAL -ELEMENT, TIME DELAY, CURRENT LIMITING FUSES. FUSES IN CIRCUITY; RATED AT 601A OR LARGER SHALL BE UL CLASS L TIME -DELAY, CURRENT LIMITING SWITCHES. MOUNTING MOUNT DISCONNECTS TO STRUCTURE, INDEPENDENT OF THE MECHANICAL UNIT HOUSING OR WITH INDEPENDENT UNISTRUT SUPPORT. DISCONNECTS MOUNTED TO UNITS ARE ONLY ALLOWED WHERE ACCEPTED BY THE LOCAL CODE AUTHORITY AND LOCATED SO AS TO NOT BLOCK ACCESS OR LABELS OF UNIT. NAMEPLATES PROVIDE PHENOLIC NAMEPLATES ON ELECTRICAL DEVICES SUCH AS DISCONNECTS AND PANELS WITH THEIR DESIGNATION (E.G. "PANEL A"). PROVIDE DIRECTORY FOR PANELS AND LABEL ALL BREAKERS. IF A TRANSFORMER IS INSTALLED, PROVIDE NAMEPLATE ON TRANSFORMER AS FOLLOWS: "HOT SURFACE, DO NOT PLACE ANY ITEMS ON TOP OR ON SIDES OF TRANSFORMER". REV # DATE FiE.CEIVEU CITY OF TUKWILA PERMIT CENTER -_ DRAWN CM CHECKED CM �e DATE 04/08/2016 REVIEWED FOR CODE COMPLIANCE ELECTRICAL NOTES APPROVED MAY 13 2016 City OT Tullwjila BUILDING DIVISION i OnO2 Y� m CL0 s N 3 0 s N Q 0 0 Z 0 W CL W 0 cz CLZ U' us W u Oil r- PANEL01 (SEC 1 2+3) 1 I I I I I 1 I I I I i I I I I � I I e . I I I I I I (3) 3-1/2" EMT (4) 600 KCMIL AL I (1) #4/OG AL ( I I I I I I i (2) 3" EMT (4) 500 KCMIL AL (1) #2G AL I L--------------------- 0 --- i n CD C ANEL COMP GENERAL NOTES: 1. ALL CONDUCTORS ARE #12 AWG CU UNLESS NOTED OTHERWISE. MC FEEDER CAN BE USED WHERE APPROPRIATE AND AT CONTRACTOR'S DISCRETION. MC FEEDER SHALL BE SIZED PER NEC REQUIREMENTS. 2. MULTI—WIRE BRANCH CIRCUITS SHALL MEET NEC 210.4 REQUIREMENTS. 3. COLOR OF ALL WIRING DEVICES AND COVER PLATES SHALL BE AS SELECTED BY THE ARCHITECT, U.N.O.. VERIFY WITH ARCHITECT PRIOR TO ORDERING. 4. COORDINATE ALL CABLE PATHWAY ROUTING IN STRUCTURE, FINISHES AND OTHER TRADES PRIOR TO ROUGH—IN. 5. EQUIPMENT SHOWN BOLD IS NEW. 6. EQUIPMENT SHOWN DASHED IS EXISTING. FLAG NOTES: INTERCEPT EXISTING RACEWAYS AND FEEDERS AT EXISTING JUNCTION BOX AND EXTEND AS INDICATED. �1 Iu mi 0 • • • • M • • • • • • 9a • o i i i s i s i e s i e e e • o e i s s e s s i i s e i s • Fastenalsee 0 • Tn • i13 - V'f - c -h . � Consignment POWER PLAN SCALE: 1/8" = 1'-0" • • • E CEIVED CITY OF TUKWILA PERMIT CENTER REVIEWED FOR CODE COMPLIANCE APPROVED I MAY 13 2016 City of TuiC hila BUILDING DIVISION, REV # DATE DRAWN CM CHECKED CM DATE 04/08/2016 NORTH POWER PLAN M 0 0 0 I V, LO R 0 0 Iri Q 0 0 0 ;_ ,Z W a I f2 W 0 CL W 5-1 FEEDER SCHEDULE ALUMINUM DATE M In LOT- LO EMT . . AMPACITY/ N co D NO RACEWAY RAC WIRE COUNT T & SIZE OC OCP SIZE NOTES 03N n 3/4 1111.___ 4 - #8 1#8 G. 1111_ 1111.._ _ _. _ _ 1111 .__._.._._ 30130 ....._.__ _ 1111.. 60 -de rating g g . 1111.... . __......... -- 1111. 1111_._ 03 03 _ 1111 1111 1111. 314" 1111... _ 3 - #8 1#8 G. 30/30 _ 1111 ... __...... 60 -de rating 9 _ 1111 04N _ _____..._ . 1111.._ .. _ ... 1111. 1111... 1 " _ 1111._ 1111._ 1111__._ ......_.... 1111.. 1111 _1111_ . 1111 4 #6 1#8 G. _. __..___... . 1111.._. 1111 1111__1111 ___...... 40 40 / 1111. 1111_ 1111 1111 _ _ _ . 1111.... _ ......._. _ _. 1111 60 -de rating 9 1111_ _-_--_.._1..1--...-11___..._._ 1111 1111.. _ 04 1 3 - #6 1#8 G. _. __..._... 40 / 40 1111 1111 1111 60 -de rating 1111_.. ... 9 .._..__._. - .. .. 1111.. 05N .._......_ 1111 ._....... n 1/ 1 4 1111.1111 --1111-- ... ......... 1111 1111..... 1111 1111.. ... 4 - #4 1 G. #8 1111.._. _ __........... _ 1111 1111 _ 1111._.._ 55/50 -- 1111 . _1111_ . _ _. 1111. __...... 1111.. -1-1 . I 60 i -de rating 9 9 _ .. _ _ 1111_._ 1111. _ _ _ --1111_._ __....... _ 1111. 05 rr 1 3 - #4 1 G. _ _ #8 55 / 50 1111 _ _ 60-d a rating 9 9 _ _ 1111 06N _ 1 1I4' 1111._ _ _ _ _ _ _ _ 4 - #3, 1#8 G. .... . _ 65160 1111 _......... _ _ _ 1111 60 -deg rating _ . _ 1111_ _ 1111 .... 06 _ 1111 1 114" _. _ _ 1111 3 #3, 1#8 G. 1111____ 65 / 60 60 -deg rating _ 1111. . 1111_ 07N 1111__ _ _ _ x 1 1/4 1111_ _ 1111 1111 _ 1111..__ 4 - #2 1#6 G. 1111 1111_ 75 / 70 _ 1111 1111 1111 .. _ 60 -de ra ' tin 9 9 7 1111 1111 1 1/4" 1111 _. _ 3 - #2, 1#6 G. 75/70 70 _ 1111 .. 60 -deg ra1.ting 08N 1 1/4" 11111111__ . .. 4 - #1, 1#� G. 1111 __ . _ - _ 85 180 _1111_. 60 -deg rating 8 1 1/4" _ 3 - #1, 1#6 G. 85 / 80 1111 1111_ 60 -deg rating _,_,___i_dN,__, 10N .____.._.._ 2" _ _..""-,_ 1111______.1111_ _6111___ _ 1111..___-_,_1,'2'__0__,/_,_1_0-0__,_ 4 - #1/0, 1#6 G. ____.___.____ ___._ 120 / 100 .... _1111 _- _.__w_. _-_.._-....., __..._._._ 75 -deg ratin .... 16 10 1 1/2 ....... 3 #110, 1#6 G. ........ ... ..........1111_ 12N 2 - 4 - #1/0, 1#4 G. ..11 ..- 120/110 ........ 1 11........1. 1.1.1-1- ... ...11..11_.... 75 -de 12 .__..._...___.._1___,---...-.---..-.-.......-...-.---.----..-..--..-.-,-.-...I......_. ._.. _.. _ _ 1 111 ,.111..1 .1111 ........___,___1-1- . _11.11-11.11_.__.. ...... 13N . ...-- _._.._..-_1.111 2 1111. 11.1_.1- -_..._.__-.. 1111-_- 4 -#210 1 #4 G. _._. 11.__._11_-. _ --1 1351 125 1111- .... _. 75 -de rating 13 _ 11--__.-- 2" . ___1111._-..9. --1111_..-._--.__.-__� ___1111__,G_ 3 - #2/0, 1 #4 G. _ _ 1111 . 13-5-J-1-2-5- 1111 1111_. 1111.... _ 1111 ..-1111... 9 1111___9 _. _......_ 75 -de ratin ______...____._..__ 15 N _..-_w_____. ,1111.._ 2 „ ___.._.____._.,.. _._..._,____-_.._-.._____ 4 - #3/0 1 #4 ._-..___.__.__._.-_.....__-.-1111.__._ / 150 .___._-,11.._11.._-_r --_-_ _. 75-- - ratan g g . .._..._._....,... _, 1111... 1111_.._, 15 1111 _ _ ... 1111,.. ... ......_. ,r 2 1111.. .. 1111. 1111 .. ... ................ _....- .. .._...__. - 3 - #3/0 1 #4 G. ., 1111_ ._.-_.......... - - 155 / 150 111 1111..__ _ 1111 11111111. ,. ...._......._..._.... _....___ '75 -deg -rating - 75 -de ratln 9 9 1111.... 11111111. _ 18N 1111_ _. _ . _. 1111.1111 . n 2 1I2 _ . 1111.1111 1111..__ _ 1111. _ 1111_... __......._ 4 - #4/0 G. 1 #4 . 1111 1111-1_----_.--111._. 180 / 175 1111... _ __....__._.. . 75 -de f rating 9 9 _ 1111 _ 1111.__ 18 1111.1111 ... ___...... 2 _ _ 1111.._ 1111.. __� 1111 1111_ ._ 1111_ 3 - #4/0 G. 1 #4 ... 1111.. 1111. 1111_.._ _ 180 / 175 1111_ ._ _ . 1111.1111 1111 . _ 1111_ 1111...... . 1111_. 75 -de rating 20N ,r 2 1/2 .......1111.. 4-250kcmil 1 #4 G. 205 / 200 - 1111._. 1111.. 75 -de ratin 9 9 .__________1111__ ZO -__-_.____.._____._...__..v_._._____...__.._.._-_.__-_.._- rr 2 1/2 3-250kcmil 1 #4 G. _ ___._.____.___.._w__ 205 / 20 _.__.___...._-._-_. .._...._ 6.11,1__..._-, 22N2 1/2 ............ -.1--... _---1-1._-1--- 1111._. _ _._._..._....__... .......... 22 2 112 ... 11 .1.. . ........_.. .......... 3-300kcmil 1 #2 G. .11. 1...1......... 230/225 ......... _......... ..._ .... 11.1..1................ 75 -de rating 9 __.___._.._._.-.1--.1.. 25N -.1--1-- 1111__ 1111_.._ ,r 3 1111 ____...._..._..._. 1111. _. -._1_...___..___...._11 4-350kcmil G , 1 #2g ._ ____....... 1111._ _ 250/250 ... ...... _._. 1111.. _.......__.._.... _....__.... ..... _ 75 -de rating ng 1111_ . ____.._...._ .. 25 1111..__ __._____ ._ _- _ 2 1/2 - _ 1111_ _ ... 1111.1111 . .. . ........... 1111 _. 3-350kcmil .. #2 G. 1111._........_ 2501250 _. _ _ 1111.. _. _ _1111__- . _..._....._.. 75 -de ratln 9 9 1111._ _ 1111._ 1111___ .._.____ 27N ______._. .r 3 _ 1111 _ 1111 _. . 1111._.. _ ........ _ ._.......__ 4-400kcmil 1 #2 G. 1111__. 1111.._ _...._...._ 270/250 1111 1111 _ _ 1111. 1111 1111 _ ..-11...... .,.. . 75-degrating 9 9 ,.,._._...,._.,_.._. 27 _...._r._�....,.....�.w-r.v 2 1/2 _:w ,111,1 .,.., 1111__ 1111,_.. 3-400kcmil 1 #2 G. , _..,.__._..�.,__._..._..._. 270 / 250 __.,.._._._.-.W.._..,.....____.. 75 -de ratin 9 9 _.______-----_._.._.__. 30N . __......_.._.._. ..-.�� .____.._..__�. 3 ,.1._. 1111 ._.._..._._.._._-__...____ 1111_ 1111_ _..._ 4-500kcm1 I, 1 #2 G. 1111 _.__..__ 1111..._ .. 1111. 3 01300 1 1111 ..._.....____. _ _ _ _ 1111_. 1111...1111.. 75 -de 'ra ' g ting 1111 _1111 1111.... _.._....._......_._.... ._ 30 3 3-500kcmil, 1 #2 G. . 1111-1111_, 310/300 1111.__ 1111. 1111 _. 75 -deg rating 1111 1111._.. _ 1111.. __.._. _..__.__ _ _ 1111.... _ 1111___ 34N 1111. 1111. � 1111.__ 3 1/2 _._�. 1111.___ 1111_..._ 1111... 4-600kcm11, 1 #1 G. 1111. 340 / 300 __ 75 -deg rating _ _ ......_._.. _ _. -. 34 1111 111 1.____ _ _._ . 3" _ 1111_..._.. _... ___...; _ -.. __.__..-.__ . __ . 3-600kcmil, 1 #1 G. __..___.._ _-....._ .....1 340/300 .11.11111 __.. . 1111... _.___......... 75 -deg rating _ ... - .1111__-__ -_ 40N . 1111.__. 1111 1111.__ 1111 _ _. ..._-... ��_- 2 2 112 (} _ ___.______._.___ -_-1111_. _ _ 1111__ .. _ 1 1111._.-1111_ _ 4-250kcmrl 1 #1 G. , .__._.__._.. _ 1111._ 1111 111------ _ _ 1111 1111._ ._ ._ _ _-0- . _ ,1111_-41--d- 410 / 400 1111__. _. _. _ ._.______ _ _. -- - _ ._ _--- _ _- --_.._-_-_._- _ _._._... 75 -de rating, 9 9 1111 ._ _. .. 1111..... 1111..-. _._.___..._.� ___..... 40 ....4 (2) 2 112" -1 3-250kcmil, 1 #1 G. __..-1_-_-.....____..._...111 _._.__._..___.._____-.. 410/400 _....._..._......__._..____._...__._.-......_.__.____.__._..__......._.....-__......-.1..-..-_._..._..___.. 75 -deg rating W-1-- 45N 4-_- (2} 2 112"4 -300kcmil, 1 #1/0 G. 4601450 75 -deg rating _.___.._4 __.......__. _.__-.___._.__....___.__._ (2) 2 1/2" ._.________..._____..._...._..___......____.._..-___._.............__..._...-.1-1-.__..___..._....__ 3-300kcmil, 1 #1/0 G. 4601450 _-___._... _11..__......_...._.._._.._._ 11_ ....... ____11_. 75 -deg rating __�,_5W ,__ 1111 1111.. _- (2}-3"--__ ._ 1111_.. 1111_.. ...��4-350kcmil, 1 #1/0G.-- 1111... 1111_. 1111 _ 1111_._ 500 1500--- ..__.___ 1111_ . _ _ ... -- ��75-deg rating---..__,_-. 1111_ 1111.1111 _ 1111_._. _ ....__...__.... __._-.__._ 50 1111 _ (2) 2 1/2" _..._..__.. 1111..._. 1111 3-350kcmil, 1 #1/0 G. _ _ _ 500i 500 1111 1111._ ._ _.:_....___...._._ 75 -deg rating .. _ ._ 1111__ 1111 1111. 1111 _ _.....__.._... 1111.. 60N 1111. 1111 1111._1111_ . _._..._...__,_.._ . 1111... (2) 3" _ 1111 . -_ _ ._.. , ....._.._ 4-500kcmtl, 1 #2/0 G. _ . _. .. _ _. 620 / 600 1111_.. 1111 ...__..._... __ 1111_ 1111.. 75 -deg rating ._..._.. _ ._..__...._. -.. 1111 . _........_. _ 60 _75N.._._1-11111 {2).3" ....... . 3-500kcmil, 1#2/0 G. ......_.._ .._.....I1--1 ....._._..._ 620 / 600 1.111... .11.11 75 -deg rating . _ ... ......1.1.1.0) .._.___......_...__......._.___.-_ (3) 3" -.___.____..___.._...._._.............-_.-.._........__........__._.._..__..._......____...___._..._._...__.__._ 4350kcmtl, 1 #3/0 G. 750 / 750 _.___...._._.._..._....._....__...___...___..._-..__-._..__.-..__...______....__..._.._.__.___.__...... 75 -deg rating 75 (3) 2 1/2" 1111......._.. 3-350kcmil, 1#3/0 G. . -_............_._.......__.._............._....__._...... 750 / 750 _...._.__........_..._..............._.......... 75 -deg rating ......_.__......_.__....................__.............._.........__._........_....._. 80N _.__._....... (3) 3" . 40 mil, 1 #3/0 G. 810 / 800 75 -deg rating --bb-__---------. _$O__..__.. _._...___..__._..___.__._- (3) 2 112 __.... _._..__...._.__. ..................._...-_1111.. _...._ ......._ 3- k-cmil, 1#3/0 G. 11111111_-__.__._-.__..__-__..... 810 /800 ____......__............_._...._._.... _....___._......_.._ __._.._.. 75 -deg rating ....._.._.._..._§..____...______._.___.._N"3 0N .....__._.._.____...__._.._ __..._...__...._.._.........__._.....__.._ (3) 3" ..__.._.._______-..........-. .................._.._._..........._........_...._..._1.___......_-......._..... 4-500kcmil, 1 #4/0 G. ____._._.............._....._..........___........_........._.__.___.___.. _..__.....-......_..___......._.._.__._.___..._....__._..__._...._......._..-._..........._._....._..._..._....._.........__..._...._...._ 930 / 900 _....._........___...._.___....____....___. 75 -deg rating __._..._-.._...._.._.____.._....___._...._......_-.-1-...___._..-.._._..... 90 _..._...._...._....._._.._._..._._......._.._____....__..__...__...___ (3) 3" 3-500kcmil, 1 #4/0 G. ..__-_._.___..............._._._..._._........_...__........._.._...-___......__...._.._......__......_....._...____..---_._ 930 /900 75 -deg rating ._......_......._..._._......___-......._............_._.._._............_......._.......__.._..._ 100N _ r. (3) 2 1/2" _:..,.... . _ .. 4-600kcmil, 1 #4/0 G. .. _ ,1111 . ,. 1111 _ 1111... 1111_ -.._ ----.-1-.-, 1020 / 1000 .�_.... _ _._.- - 75 -deg rating _.W_ ,_ -1 , 111,1.. 1111. . 100 (3) 3" 3-600kcmil, 1#4/0 G. 1111._._..._..._. __..__.. 1024 11000 ......._....__.__ 75 -deg rating __._....._ _ _-...__..__ 120N -(4} 3" -~ _._._.._ 1 #250 G. 1240 / 1200 11 .;t g rating _ .._-120 �.._..(4P 3" ......__ _4-500kcmtl, 1111..._- -". 1111__._ _ 3-500kcmtl, 1 #250 G. .......... _.________.___._.___ 1240 / 1200 ..._ ...... - ... _�.... . _..75 -deg rating- ._mm,W- _........ 1111.. .... -1... 150N ......... 1 111... ....._ {5) 3" _ _.. _ .1111 . ..... ..1.1.1..1 ... .1111... 4-500kcmil, 1 #350 G. _ 11 - _...... 1550/1500 .1 ... ...... .. I. .-11. .... 11.. _.._ ...... 11 75 -deg rating ... 1111... - _.. _. ........ 150 . {5) 3" ... ..111......1 _ _ 3-500kcmil, 1 #350 G. .. 1550/1500 ... ._ 1111.._. 75 -deg rating .- _._...____.._.._11 160N 11-___.___.__._....._._.__ (6} 3" _____...__._.......___---._...__..____.._..__._._..._._..� 4-400kcmit, 1 #350 G. ___..___._._..._-.__._.._ 1620/1600 __............._.._._.____._.__....._.__.__._._..__..._....._.. 75 -deg rating __.-______._�__.._....._.....___._.._..l 160 ._.._.__..__....__..-.._....._._._._..._..__...__..__..__._._..._.......______.__..__ (6) 2 1/2" _.._...__._...__ 3-400kcmil, 1 #350 G. __.__._._._.__.__-___.____ .............___-...__1111 .____...._._-..._-___.-...._-_..-_...._......_.._........_..._..__-.___.__.._....__...__.._._.__. 1620/1600 ..____.__._.__.-_..__._-_ 75 -deg rating ._._._.___.._._---____._....._.__..___....._._____.__._. _.....______..._--1111.__ 20oN _ _._.._. (6) 2 1l2" . - 4-600kcmil, 1#400 G. - M1 2040/2000 --2040/2000-,- _ 75-de_g rating_ W ___-75 200 (6)rv3" 3-600kcmil, #400 G. -deg 75 -deg rating NOTE: Based on THHN insulation, EMT conduit and Chapter 9, Table 4 and Table 5a fur campact`I 1.AL wire, of the NEC; 2008 edition- I - Indicates acceptable or,ercurrent device rating far single feeder. This rating shall ss�_.____._ ____._-__.__......_...-_-_..._-.-._....._...___..._.._.._..__---__v_____,__ ____.____..__.._-.-- not used for sizing parallel feeders._.._._____..-__. __ ___.__.__._._______.__._.. _.____.____.___.__._______ . -- ..._.____...._-_1- .... 11 11--_.._.___._.---.______....__ ___.__._.__.._ __.._..__ .--------_-____-_-.-__-.._-----._.__-._..__.._....._._.__-__.__...-1111__---.-_-.._-_.__....___..1111 1111__..1111__ __.-_1_.___-.._...._.. .11...._....__.._-_ "* -Indicates overcunent protective device rating that may be used fur this feeder. The Contractor shall install feeder size indicated even if Code allows 3-___.___.______-�___.__._.,_._.__..____.._.________.________..---1111._.---- ____._.__-_________. smaller to be used. GENERAL NOTES: 1. ALL CONDUCTORS ARE #12 AWG CU UNLESS NOTED OTHERWISE. MC FEEDER CAN BE USED WHERE APPROPRIATE AND AT CONTRACTOR'S DISCRETION. MC FEEDER SHALL BE SIZED PER NEC REQUIREMENTS. 2. RISER DIAGRAM IS NOT REPRESENTATIVE OF ACTUAL SWITCHBOARD LAYOUT. SEE ELECTRICAL ROOM(S) (SHEET E2.01 -E2.04) AND PANEL SCHEDULES (SHEET E5.02 FOR PHYSICAL A C ICAL L YOUT WITH RESPECT TO ACTUAL MANUFACTURED AND POTENTIAL INSTALLED CONDITIONS. 3. EQUIPMENT SHOWN BOLD IS NEW. 4. EQUIPMENT SHOWN DASHED IS EXISTING. 5. ALL SWITCHBOARDS AND PANELBOARDS SUPPLIED BY A FEEDER SHALL BE MARKED TO INDICATE THE DEVICE OR EQUIPMENT WHERE THE POWER SUPPLYS PER ORIGINATE R NEC 408.4(B). B . 6. REFER TO FAULT CALCULATION SUMMARY ON SHEET EO.03 FOR FURTHER CLARIFICATION. FLAG NOTES: EXISTING INDOOR BUSWAY: 1000A, 208Y/120V 3PH, 4W, HOUSING GROUND, 100% NEUTRAL 2 ELECTRICAL CONTRALTO TO PRO L S A R VIDE PHENOLIC LASE STATING PANE L NOT TO EXCEED 600AA . 3 INTERCEPT EXISTING N RACEWAYS AND FEEDERS AT NEW JUNCTION BOX AND EXTEND AS INDICATED. INTERCEPT EXISTING RACEWAYS AND FEEDERS AT 4 EXISTING JUNCTION0 BX AND EXTEND AS INDICATED. DATE M In LOT- LO N r N . . N co co N RED DOT- SERVICE LOAD CALCULATION W Z Z o L- 111111111111111111111Z SERVICE VOL- 11TAGE ===>1-1 ' 480V1-1 U 3Ph ry!P ti 11111111___ .-._ _ _. _ . I- _ _ 1__ 1. _11_-_ _ . -.__ _.- _ l 1111 - . _ -.I11..-...11. 11.._ _ 1111 I BASELINE _. 1111 1111- 1111_._.. _ 1111.. 1111. _ 1111 1111 _1- -1 -II- ... _ .1111 __1.111.. _-11-..__-___.__-..--.-,-- - _ , 1111. __..____ _ _ . _ ......._ ._ _ .... ... _ 111.1 _ . _ 1111_ ._ - 1111 1111 ....- ...._ _-1111... 1111 .. - ...___.._ 1111 111.1 111 1 1111_._.. _ 1111,_ ... I.... ._ . 111_.._1.. 1111... 1111... 1111 . -,_ . _ 1111._ 1.1 1 _ _ _ ... _ - .. __.. _.. _... 1111 _......__ .___ . SQUAREFOOTAGES PER FLOOR . _ .. ___.. _. 1111.__.. -....1111. ,11..".",".1." 1111..___ .111.1.._.. 1111 I-----1-1-....__-_-_ 11._. _ # OF FLOORS 1111_. 1111 _ 1 1-11-1-1 TOTAL _. 1111._ _ 1111__ 1111 1111_ . _ . _ . _ 1111 _. _ 1111. _ -__ _ - 1111__._._ _.____ ___---.----.-__1__1-1-1 _ 1111..... I. TENANT SPACE 1. 12000 SQ FT : 1 12000: SQ FT 1--.11-- 11._ ....1._.._ .. .1111.... _ -1-11--_ ._...._ . _ , .__1.._. _. -_... _ _...1111 1111-......__._1 ....... "I . I..-1111 .I... -II -I.. _-.11- 11 . BUILDING TOTALS SQUARE FOOTAGE _> Q 12 000 _111.1.._, S FT Q _ 11-- _.1.111- __..._..._ ._.. - --- _.. . -11. _.1 1 1.. ._ 1111___. ._.. _.....- BUILDING INFORMATION . EXISTING _ BUI DI 11-1 --- -- _11-11-11 _ 1-_---.__1_--_-,. _ 1111 _ __._ _ 11 1_ - _. _ - _ -1111__. _ .._....___ ... I.,. DESCRIPTION _ 1111 _ _ - _ DEMAND, ..... . _.. _.1.1 11 - --- PF KVA - _ _ .. ---__ 125% __ ....... ._.. _.. _ _ 1 111 ,.111..1 .1111 ........___,___1-1- -__ .... 1111 TOTAL 1111 _. __ _ . _ . _-- PEAK UTILITY DEMAND (03/2015 - 03%2016) .- ...11 1111_ _ _11. _ 165.51 1 165.51 ' 41.38 . _ _ _ _ 1 _ 206.89 . ._ _ KVA _1111 I :II1111 1111_ .11._ __1 _. PEAK MONTH WAS FEBRUARY 2016 ( ) _ _ 1111 .. _ . _ 1111...._ _ I. . - - _ .-II II 1111.__. _ II _ S. MISCELLANEOUS, HOUSE/EQUIPMENT LOAD SS 11 11 _ _ EQUIPMENTALLOWANCES 111 1 ..._. _. . ... . _ .. . HP EQUIP EQUIP A NEC NEC DESCRIPTION HP - V PH KW KW AMPS KW QTY dEMANO REFERENCE -: TOTAL INJECT1. ION MOLDING MACHINE111-1-11 1111-:: 480 3 200 i 166.3 1 100% % _.___1_6 6-.281-1 KVA 1111 1111_. 1111 1111_1 _ _ 1111.1111 _ _. 1111.1111. MATERIAL DRYER _ 1111 - 480 1111. ; 3 1111. _ 1111 1111.. _ 1111 1111_ 23 _ .. 19.12 . ....1111_ 1111 1 _ __ _ _ 11111 _ 100% _ ._ 1111.1111. 19.12 1111_ _ _ _. KVA .._ .... 11.11........._ ._ . _ ... . _. _ -_.... 1-1...........1.-..... . ........ _ ......... _ ......... ...... ...11..... ....... MATERIAL LOADER ._..... .1.11 ..,1..._ .. 1111 120 1 :.. .- .... 1. ..11.1 11.... 1.1..... 10 ........ 1.2 ..__.. 1 _ _ ._ .....- . ... ...1.1.11 100% _____-_1-_..11 1.20 .. ... _. KVA 1111 _ COLOR I E MXR _. ; 120 i 4 0.48 1 ... .._ 0 100% .. 0.48 ._ ..... ... ..... KVA -..1.-.._-...-_ _ ..." -I.-'...'.. I....-.. . -............ ._. I_ ..... --. ..._....... -.. I. .........._.. _.. .-_11._11.__ . --_ _......__..1111. 11.1...1_. MOLD HEATER -.._....1_----._-...._._."1.. ._ _----_ -- 480 3 ....- __.-1111_ __.___ . _ _-._11 _ ._ 11.1_ 17 _ ....._- 14.13 1.111._ ... 1 _.. .1111..._ 1111-. ..._ ..._.._ 1-,.-......-..,1--1_.,,,-.,_,._.,__-,-, 100% __.. 14.13 -..11_. 1111._._ 11....11. KVA -._ 111. 11_..._ _ ..._ ._. _ . ._ _.._ 11 _ _ _ 1111. _-_-.. 1111_...,.. __ ... _. . _ ._...... _ _._ 1111 _... CEILING FAN -. _ - 1.-- :11- ....1111 480 3 ,_ _ .__.. ........ _ .-_.-1..--_--.-...---.-..-- _ .. _.... 1111 _ ...1 6.7 1....1-..1---... 5.57 _ . 111..1. -,-._ 1 __ . . _ . 11 __ 1.1.1 _ _1. ...... 100% _1. ........ 5.57 - _-.. _ . ..... ...... _ _ .... KVA _ .1111.._ .... . _ 1111. 1111____..._. ... _... .._._._._.._-1111_.__ 1111.._ _....___. __ _ 1111._ _ ._._ 1111 1111_ _ 2ND CALORIMETER SYSTEM 1111_. 1111..1----..--._..- ,.. 480 3 -..._ _ ._ -1... -1111---.1 _ ..._. _1111__ _ �.'.__ 490 _. -1111_ .. 407.4 -- __. __. 1 .,.1.. _. ._.-..__.-111._.1--.-..1.111 _ -1111.__ ...._ w_ 100% 1. ..11.11._ .. 407.38 - ..... - - -1111_. KVA .....1_...1._.-.I-...-- ._ ......11 .. _11.11 1111 _ .... 11 ...--...._.__,._._._ 111.,1 _ - -- _ BRIDGE CRANE#I 1111..__..._ ..1111_... _- _ 11 11... 1111_-- _ 11' 11_._._-_.___.....__...___._______ _.1111 .._ .._ _._... 1111.. 1111 .1111 . 1-. 480 . _.111 1... 3 _ 1111.1111:1111. _. _ 1111.... 1111. -'...,1 _ ......._ 1.- 1111.. ._.......-_ 111 _. 60 _.....__ 11111111 ... 1111 --1111. 49.88 _ 1111. _. .1111.. 1 1111 1 111__ .. ..__. ._-- _11 _ ...1 , 100% :111 _ ..._._.._ _ _ ;_......_ 1111-..... .. ,:-____-...-1--11I.1-____._- 11.1......__ 49.88 .. .11.11_.. .111.1.. 1111_ KVA ;___..11..1_..1...._-. 11....._.- . - 1111 _.._ _...._._.._-._._ .111.1. ..----C. - _.-_ _ ..-j _ _ ._._ _ _ .......11.1111 _- _.. _. _. 1111. ....11.. _ 111 _ .. _ _:; ...1111 .. -.. 1 .111__ .... 11..11.1111. -" 11.11 ._.. -- -- _... _ TOTAL MISCELLANEOUS ....... -.. ,__1.__.... _ .........I--__-1.---1.... __ - ._. HOUSE/EQUIPMENT LOADS==> 664.04 11.11.. _. _ .. -._. _. -_, .11__11.. . KVA GENERAL NOTES: 1. ALL CONDUCTORS ARE #12 AWG CU UNLESS NOTED OTHERWISE. MC FEEDER CAN BE USED WHERE APPROPRIATE AND AT CONTRACTOR'S DISCRETION. MC FEEDER SHALL BE SIZED PER NEC REQUIREMENTS. 2. RISER DIAGRAM IS NOT REPRESENTATIVE OF ACTUAL SWITCHBOARD LAYOUT. SEE ELECTRICAL ROOM(S) (SHEET E2.01 -E2.04) AND PANEL SCHEDULES (SHEET E5.02 FOR PHYSICAL A C ICAL L YOUT WITH RESPECT TO ACTUAL MANUFACTURED AND POTENTIAL INSTALLED CONDITIONS. 3. EQUIPMENT SHOWN BOLD IS NEW. 4. EQUIPMENT SHOWN DASHED IS EXISTING. 5. ALL SWITCHBOARDS AND PANELBOARDS SUPPLIED BY A FEEDER SHALL BE MARKED TO INDICATE THE DEVICE OR EQUIPMENT WHERE THE POWER SUPPLYS PER ORIGINATE R NEC 408.4(B). B . 6. REFER TO FAULT CALCULATION SUMMARY ON SHEET EO.03 FOR FURTHER CLARIFICATION. FLAG NOTES: EXISTING INDOOR BUSWAY: 1000A, 208Y/120V 3PH, 4W, HOUSING GROUND, 100% NEUTRAL 2 ELECTRICAL CONTRALTO TO PRO L S A R VIDE PHENOLIC LASE STATING PANE L NOT TO EXCEED 600AA . 3 INTERCEPT EXISTING N RACEWAYS AND FEEDERS AT NEW JUNCTION BOX AND EXTEND AS INDICATED. INTERCEPT EXISTING RACEWAYS AND FEEDERS AT 4 EXISTING JUNCTION0 BX AND EXTEND AS INDICATED. Z O H . 9 v W a0 0o . 0 Z v . 00 I I 0. CK,v__ �aQ � O Umo- 0 �_ LO d-¢= O Dti� EXTERIOR INTERIOR Q NEMA 3R NEMA 1 W i�T�Ti�Ti C ■ M It "010 : ■ CL CL CL CL CL CL CL n 0- o- CL CL CL n CL CL o- P7 n P7 r7 CL n \� M Li n M n n \ n . n CL a- P7 \ \ \ \ I'7 \LL_ NEW PSE a s \¢ \LL. \Ii \LL_ \Lr_ w "-L_ \I.,-. M \Li W w w w \LL- Q Q 00 QO QQ QQ << QQ U QQ QQ \LL. \L_ QQ U C.) 0 U Q¢ 00 UTILITY TRANSFORMER 00 00 00 00 00 00 ¢ OO 00 ¢¢ QQ 00 ¢ ¢ ¢ ¢ 00 00 OCD 00 00 00 00 00 CL 00 00 00 00 00 CL CL CL CL 00 00 o d- N o c0 cD 4 d- d- o d- d- o N N o to d- d- o c0 c0 o cfl CL) o c� cfl o N N o (n Cn (n Cn cD cfl o r r- `-" ZII� IELECT GRADE � ROOM � LOOPED L- _---_-_J I SWITCH TO Ui1LITYcL-- --J (6 SETS) 4" PVC -40 (4) 750KCMIL AL (EACH) XFMR VAULT MAIN DISTRIBUTION SWITCHGEAR (MDS) 1600A, 480Y/277V, 3P, 4W, NEMA 1 65,000 AIC I .r 3/0 CU MAIN WATER PIPE PROVIDE UFER GROUND: 20' BARE COPPER CABLE IN CONCRETE FOOTING SIZED AND EXOTHERMIC WELD OR INSTALLED PER NEC 250-81(c) OTHER APPROVED METHOD BOND TO MAIN WATER PIPE. PARTIAL ONE -LINE RISER DIAGRAM SCALE: NTS 480Y/277V 208Y/120V 1 757 758 BRANCH BRANCH 55 330 200 80 300 330 200 200 55 80 720 DIST DIST TON TON TON TON TON TON TON TON TON TON TON 'PANEL' PANEL' 'PANEL' 1(' �) ✓ , � `�' `�% `✓�% 1� °✓�% ✓`% `✓_% 1 I 1 I I \ % ♦ 1, \ \ \ ♦ \ \ % / I H1 H1 I L1 I T T T T T T T T T T T 1 I I 1 I I I I I I I I I I I 1 I (SEC1)1(SEC2 1 1 1 400A ' 400A ' , 400AMCB 11 ,l 1100A 100A 100A 100A 125AF 100A 100A 100A 100A 100A ' MLO I MLO ; I MCB ; ;�H 6OAF 50AF 50AF 50AF 125AF 80AF 70AF 60AF 50AF 50AF ' L----'L------J L- '1 -I-J19 r-, I T I i 1 06 I 05 ' 05 j j i ! I! �_ --J -- -� I I I I I I I I I ! j �-1111__--11111111-� ! I I I I I I I I I I I I I I I ! I I I I I I I I I ! -�-- ! I I I I I I 150kVA; I I I I 1 =_= 1 ' ' ' XFMR - � , I I I I I I I I T-� I I I I I I= i I I I I I I I I j #3G I I I I I I I I I I I ! ! ! I I I I I I 1 I I I I I I I I I I _]_ -1111-- I I I I I I I 4 I I j -- I I -----------I -- I j ' � I I r ;PANEL; , I I COMP ;