Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Permit EL16-0589 - SEATTLE CHOCOLATE - REMODEL
SEATTLE CHOCOLATE 1180 ANDOVER PARK W EXPIRED 11/11/17 ELl 6=0589 } City of Tukwila . Department of Community Development * 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: Z06-431-3670 Inspection Request Line: 206-438-9350 Web site: http://www.TukwilaWA.gov Parcel No: 3523049085 Address: 1180 ANDOVER PARK W Project Name: SEATTLE CHOCOLATE ELECTRICAL PERMIT Permit Number: EL16-0589 Issue Date: 9/26/2016 Permit Expires On: 3/25/2017 Owner: 2015 National Electrical Code: 2014 Name: DANELLIE LLC WA Cities Electrical Code: Address: 1180 ANDOVER PARK WEST, 2015 WAC 296-46B: TUKWILA, WA, 98188 Uniform Plumbing Code Edition: Contact Person: WA State Energy Code: 2015 Name: HENRY KURASAKI Phone: (206) 962-6513 Address: 1101 SECOND AVE, SUITE 100, SEATTLE, WA, 98101 Permit Center Authorized Signature: Contractor: Date: ` Name: EXACT ELECTRIC LLC Phone: (206) 434-6915 Address: 10115 GREENWOOD AVE N BOX 233, SEATTLE, WA, 98133 License No: EXACTEL927RK Expiration Date: 12/12/2016 Lender: Name: Address: , DESCRIPTION OF WORK: REMODEL OF EXISTING SPACE, DEMOLITION AND RELOCATION OF A PORTION OF THE ELECTRICAL EQUIPMENT, ADDITION OF LIGHTING AND CIRCUITS IN THE REMODELED SPACES. Valuation of single family: $0.00 Fees Collected: $1,356.74 Valuation of mf/comm: $55,000.00 Type of Work: TENANT IMP Electrical Service Provided by: PUGEST SOUND ENERGY Water District: TUKWILA Sewer District: TUKWILA Current Codes adopted by the City of Tukwila: International Building Code Edition: 2015 National Electrical Code: 2014 International Residential Code Edition: 2015 WA Cities Electrical Code: 2014 International Mechanical Code Edition: 2015 WAC 296-46B: 2014 Uniform Plumbing Code Edition: 2015 WA State Energy Code: 2015 International Fuel Gas Code: 2015 ��� Permit Center Authorized Signature: Date: ` I hearby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulaxin construction oo the performance of work. I am authorized to sign and obtain this development permed ree to the cpfiyhpns attached to this permit. Signature: Print Name: 1nr)t�P� I'Ie Date: W Z6 //6 This permit shall become null and void if the work is not commenced within 180 days for the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. PERMIT CONDITIONS: 1: 'ELECTRICAL PERMIT CONDITIONS' 2: A copy of the electrical work permit shall be posted or otherwise made readily accessible to the Electrical Inspector at each work site. 3: Approved plans shall be maintained at the construction site and shall be readily available to the Electrical Inspector. 4: All electrical work shall be in accordance with NFPA 70 - NEC, and requirements for electrical installations, Chapter 296-46B WAC. S: When any portion of the electrical installation is to be hidden from view by permanent placement of parts of the building, such equipment shall not be concealed until it has been inspected and approved by the Electrical Inspector. 6: The issuance of an electrical work permit shall not be construed to be a permit for, or an approval of, any violation of the provisions of the electrical code or other ordinances of the jurisdiction. Permits or related documentation that presumes to grant this authority are therefore not valid. 7: Any change in the scope of work described by the electrical work permit shall require additional work permits. Where approved plans have been issued, revisions to the plans and additional review may be required. PERMIT INSPECTIONS REQUIRED Permit Inspection Line: (206) 438-9350 2100 ELECTRICAL FINAL 7003 ROUGH -IN ELECTRICAL 7002 SERVICE 7001 UNDERGROUND/SLAB CITY OF TUKWILA Aw Community Development Department Permit Center • 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 hq://www.TukwilaWA.gov Electrical Permit No. Project No. Date Application Accepted: Date Application Expires: use ELECTRICAL PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. "Please Print" SITE LOCATION King Co Assessor's Tax No.: Site Address: 1180 ANDOVER PARK WEST Suite Number: Floor: 1 Tenant Name: SEATTLE CHOCOLATE New Tenant: ❑..... Yes ®..No PROPERTY OWNER Name: JEAN THOMPSON Address: 1180 ANDOVER PARK WEST City: SEATTLE State: WA Zip: 98065 CONTACT PERSON — person receiving all project communication Name: HENRY KURASAKI (MG2) Address: 1101 2ND AVE, SUITE 100 City: SEATTLE State: WA Zip: 981.01. Phone: (206) 962-6513 Fax: Email: henry.kurasaki@mg2.com ELECTRICAL CONTRACTOR INFORMATION Company Name: TBD Address: City: State: Zip: Phone: Fax: Contr Reg No.: Exp Date: Tukwila Business License No.; Valuation of Project (contractor's bid price): $ 55,000 Scope of Work (please provide detailed information): Remodel of existing space, demolition and relocation of portion of electrical equipment, addition of lighting and circuits in remodeled spaces. Will service be altered? ❑ Yes m No Adding more than 50 amps? ❑ Yes m No Type of Use: Type of work: ❑ New ❑ Addition ❑ Service Change 0 Remodel ❑ Tenant Improvement ❑ Low Voltage ❑ Generator ❑ Fire Alarm ❑ Telecommunication ❑ Temporary Service Property Served by: ❑ Puget Sound Energy ❑ Seattle City Light M"MlicationsWorms-ARtications On Lme12014 Applications%leetrical Revised: January 2014 bh Permit Application Revised 1-1-14.doat Page 1 of 2 RESIDENTIAL NEW RESIDENTIAL SERVICE ❑ New single family dwellings ................................... $152.85 (including an attached garage) ❑ Garages, pools, spas and outbuildings ........................ $81.90 ea ❑ Low voltage systems (alarm, fuinace thermostat) ................................ $59.85 ea PERMIT APPLICATION NOTES - MULTI -FAMILY AND COMMERCIAL Fees are based on the valuation of the electrical contract. MISCELLANEOUS FEES ❑ RESIDENTIAL REMODEL AND SERVICE CHANGES $65.00 ❑ Service change or alteration ...................................... $81.90 ❑ (no added/altered circuits) $86.25 ❑ Service change with added/altered circuits ................. $81.90 ❑ number of added circuits ....................... $11.55 ea ❑ . Circuits added/altered without service change ........... $54.60 (up to 5 circuits) $10.80 ea 0 Circuits added/altered without service change ........... $54.60 (6 or more circuits) ............................................... $7.65 ea ❑ Meter/mast repair ....................................................... $68.25 ❑ Low voltage systems ................................................. $59.85 (alarm, furnace thermostat) PERMIT APPLICATION NOTES - MULTI -FAMILY AND COMMERCIAL Fees are based on the valuation of the electrical contract. MISCELLANEOUS FEES ❑ Temporary service (residential) ................................. $65.00 ❑ Temporary service (generator) ................................... $80.90 ❑ Manufactured/mobile home service ........................... $86.25 (excluding garage or outbuilding) ❑ Carnivals.................................................................... $80.60 Number of concessions ......................... $10.80 ea Each ride and generator truck ............... $10.80 ea ***EFFECTIVE JANUARY 1, 2014 EACH PERMIT WILL BE ASSESSED A 5% TECHNOLOGY FEE*** Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The Building Official may grant one extension of time for an additional period not to exceed 90 days. The extension shall be requested in writing and justifiable cause demonstrated. I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER OR ELECTRICAL CONTRACTOR: Date: 6- Z�f 1(0 Print Name: t/ kr1`tp--,—( kL(A 14&A,.l<—j Day Telephone: Z -"O' `Z.6 2 ' 13 5 1 Mailing Address:l00 Sia�-r'rLt-= wA r City State Zip HAAppGwtions\Fo AppGcstions On Line\2014 ApplieationsTte trieal Permit Application Revised 1-1-14.doex Revised: January 2014 bh Page 2 of 2 DESCRIPTIONS PermitTRAK • QUANTITY' $3,861.57 D16-0180 Address: 1180 ANDOVER PARK W Apn: 3523049085 $2,109.33 DEVELOPMENT $2,009.10 PERMIT FEE R000.322.100.00.00 0.00 $2,004.60 WASHINGTON STATE SURCHARGE B640.237.114 0.00 $4.50 TECHNOLOGY FEE $100.23 TECHNOLOGY FEE R000.322.900.04.00 0.00 $100.23 EL16-0589 Address: 1180 ANDOVER PARK W Apn: 3523049085 $1,095.83 ELECTRICAL $1,043.65 PERMIT FEE MULTI-FAM/COMM R000.322.101.00.00 0.00 $1,043.65 TECHNOLOGY FEE $52.18 TECHNOLOGY FEE R000.322.900.04.00 0.00 $52.18 M16-0110 Address: 1180 ANDOVER PARK W Apn: 3523049085 $304.13 MECHANICAL $289.65 PERMIT ISSUANCE BASE FEE R000.322.100.00.00 0.00 $32.50 PERMIT FEE R000.322.100.00.00 0.00 $257.15 TECHNOLOGY FEE $14.48 TECHNOLOGY FEE R000.322.900.04.00 0.00 $14.48 PG16-0086 Address: 1180 ANDOVER PARK W Apn: 3523049085 $352.28 PLUMBING $335.50 PERMIT ISSUANCE BASE FEE R000.322.100.00.00 0.00 $32.50 PERMIT FEE R000.322.100.00.00 0.00 $303.00 TECHNOLOGY FEE $16.78 TECHNOLOGY FEE TOTAL . R9034 R000.322.900.04.00 0.00 $16.78 $3,861.57 - Date Paid: Friday, July 22, 2016 Paid By: RONALD WOLFF Pay Method: CREDIT CARD 022956 Printed: Friday, July 22, 2016 12:11 PM 1 of 1 orrsreIAs DESCRIPTIONS PermitTRAK ACC• QUANTITY PAID $1,720.19 D16-0180 Address: 1180 ANDOVER PARK W Apn: 3523049085 $1,302.99 DEVELOPMENT $1,302.99 PLAN CHECK FEE R000.345.830.00.00 0.00 $1,302.99 EL16-0589 Address: 1180 ANDOVER PARK W Apn: 3523049085 $260.91 ELECTRICAL $260.91 PLAN CHECK FEE R000.345.832.00.00 0.00 $260.91 M16-0110 Address: 1180 ANDOVER PARK W Apn: 3523049085 $72.41 MECHANICAL $72.41 PLAN CHECK FEE R000.322.102.00.00 0.00 $72.41 PG16-0086 Address: 1180 ANDOVER PARK W Apn: 3523049085 $83.88 PLUMBING $83.88 PLAN CHECK FEE TOTAL PAID RECEIPT: R8828 R000.322.103.00.00 0.00 $83.88 $1,720.19 Date Paid: Monday, June 27, 2016 Paid By: HENRY KURASAKI Pay Method: CREDIT CARD 49138D Printed: Monday, lune 27, 2016 7:49 AM 1 of 1 r- ?r' [ � y57EM5 INSPECTION RECORD Retain a copy with permi1644-0t INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Project: 4 61+0 Type of Inspection: �h L/ Address: "n % f 'Q® 1! Date Called: Special Instructions: Date Wanted: �,.— a.m .m. Requester: Phone No: f �� ElApproved per applicable codes. LJ Corrections required prior to approval. COMMENTS: Th Polk C i I''rI uj "12 (Inspector. A- ho t 1te 4tr' (Date: o 1 � �h 7 REINSPECTION FEE REQUIRED. Prior to next inspection, fee frust be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. �y INSPECTION RECORD / Retain a copy with permit INSPECTION NO. PERMIT N0. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Project: 640c' -' Type of Inspection: �/f �F1 Address: YO Date Called: Special Instructions: Date Wanted:a.m. Requester: Phone No: F] Approved per applicable codes. Corrections required prior to approval. COMMENTS: tj at �® ® 4— GS 144' 6 a Cllh%�v' Y Q -r INSPECTION RECORD Retain a copy with permit t� INSPECTION N0. PER N0. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 MApproved per applicable codes. LJ Corrections required prior to approval. nspector: REINSPECTIPN FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT N10. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Project: '. 0T pe of Inspection: ®g a 14 Address: Y0 Date Called: Special Instructions: Date Wanted: / a.m p.m. Requester: Phone No: ElApproved per applicable codes. 11 Corrections required prior to approval. I paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. INSPECTION RECORD Retain a copy with permit CU6 INSPECTION NO. P RMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Project: Type of Inspection: r [ 44 C I Address:so X� Date Called: Special Instructions: Date Wanted: .m. Requester: Phone No: FlApproved per applicable codes. u Corrections required prior to approval. tJ paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. 9/29/2017 City of Tukwila Allan Ekberg, Mayor Department of Community Development Jack Pace, Director HENRY KURASAKI 1101 SECOND AVE, SUITE 100 SEATTLE, WA 98101 RE: Permit No. ELI 6-0589 SEATTLE CHOCOLATE 1180 ANDOVER PARK W Dear Permit Holder: In reviewing our current records, the above noted permit has not received a final inspection by the City of Tukwila Building Division. Per the International Building Code, International Mechanical Code, Uniform Plumbing Code and/or the National Electric Code, every permit issued by the Building Division under the provisions of these codes shall expire by limitation and become null and void if the building or work authorized by such permit has not begun within 180 days from the issuance date of such permit, or if the building or work authorized by such permit is suspended or abandoned at any time after the work has begun for a period of 180 days. Your permit will expire on 11/11/2017. Based on the above, you are hereby advised to: 1) Call the City of Tukwila Inspection Request Line at 206-438-9350 to schedule for the next or final inspection. Each inspection creates a new 180 day period, provided the inspection shows progress. -or- 2) Submit a written request for permit extension to the Permit Center at least seven(7) days before it is due to expire. Address your extension request to the Building Official and state your reason(s) for the need to extend your permit. The Building Code does allow the Building Official to approve one extension of up to 180 days. If it is determined that your extension request is granted, you will be notified by mail. In the event you do not call for an inspection and/or receive an extension prior to 11/11/2017, your permit will become null and void and any further work on the project will require a new permit and associated fees. Thank you for your cooperation in this matter. Sincerely, W Rachelle Ripley P Y Permit Technician File No: ELI 6-0589 6300 Southcenter Boulevard Suite #100 • Tukwila, Washington 98188 • Phone 206-431-3670 9 Fax 206-431-3665 5/1/2017 City of Tukwila Allan Ekberg, Mayor Department of Community Development Jack Pace, Director HENRY KURASAKI 1101 SECOND AVE, SUITE 100 SEATTLE, WA 98101 RE: Permit No. EL16-0589 SEATTLE CHOCOLATE 1180 ANDOVER PARK W Dear Permit Holder: In reviewing our current records, the above noted permit has not received a final inspection by the City of Tukwila Building Division. Per the International Building Code, International Mechanical Code, Uniform Plumbing Code and/or the National Electric Code, every permit issued by the Building Division under the provisions of these codes shall expire by limitation and become null and void if the building or work authorized by such permit has not begun within 180 days from the issuance date of such permit, or if the building or work authorized by such permit is suspended or abandoned at any time after the work has begun for a period of 180 days. Your permit will expire on 6/20/2017. Based on the above, you are hereby advised to: 1) Call the City of Tukwila Inspection. Request Line at 206-438-9350 to schedule for the next or final inspection. Each inspection creates a new 180 day period, provided the inspection shows progress. -or- 2) Submit a written request for permit extension to the Permit Center at least seven(7) days before it is due to expire. Address your extension request to the Building Official and state your reason(s) for the need to extend your permit. The Building Code does allow the Building Official to approve one extension of up to 180 days. If it is determined that your extension request is granted, you will be notified by mail. In the event you do not call for an inspection and/or receive an extension prior to 6/20/2017, your permit will become null and void and any further work on the project will require a new permit and associated fees. Thank you for your cooperation in this matter. Sincerely, 7R Bill Rambo Permit Technician File No: EL16-0589 6300 Southcenter Boulevard Suite #100 • Tukwila, Washington 98188 • Phone 206-431-3670 • Fax 206-431-3665 PERMIT COORD COPS( PLAN REVIEW/ROUTING SLIP PERMIT NUMBER: EL16-0589 DATE: 06/27/16 PROJECT NAME: SEATTLE CHOCOLATE SITE ADDRESS: 1180 ANDOVER PARK W X Original Plan Submittal Revision # before .Permit Issued Response to Correction Letter # Revision # after Permit Issued DEPARTMENTS: Building Division Fire Prevention ❑ Planning Division ❑ Public Works ❑ Structural ❑ Permit Coordinator PRELIMINARY REVIEW: DATE: 06/28/16 Not Applicable ❑ Structural Review Required ❑ (no approval/review required) REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: Approved 0 Corrections Required ❑ (corrections entered in Reviews) Notation: DUE DATE: Approved with Conditions K" Denied ❑ (ie: Zoning Issues) REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: 07/26/16 12/18/2013 Exact Electric LLC Washington State Department of CAO Labor & Industries Exact Electric LLC Owner or tradesperson Principals Euse, Zachary F, PARTNER/MEMBER Doing business as Exact Electric LLC WA UBI No. 602 872 261 License Home. Espanol Contact Safety & Health Page 1 of 2 Search L&I A -'L Index Help My L&I Claims & Insurance Workplace Rights Trades & Licensing 10115 GREENWOOD AVE N BOX #233 SEATTLE, WA 98133 206-434-6915 KING County Business type Limited Liability Company Verify the contractor's active registration / license / certification (depending on trade) and any past violations. Electrical Contractor Active. ........... Meets current requirements. License specialties GENERAL License no. EXACTEL927RK Effective — expiration 12/12/2008-12/12/2016 Designated administrator FUSE, ZACHARY F License type Electrical Administrator Bond TRAVELERS CAS & SURETY CO Bond account no. 105190489 Received by L&I 12/12/2008 Savings No savings accounts during the previous 6 year period. License Violations No license violations during the previous 6 year period. Workers' comp Active. Meets current requirements. License no. EUSE'ZF939D6 $4,000.00 Effective date 12/05/2008 Expiration date Until Canceled Do you know if the business has employees? If so, verify the business is up-to-date on workers' comp premiums. L&I Account ID Account is current. 168,213-00 .................._.....__.. Doing business as EXACT ELECTRIC LLC Estimated workers reported https:Hsecure.ini.wa.gov/verify/Detail.aspx?UBI=602872261 &LIC=EXACTEL927RK&SAW= Help us improve 9/26/2016 Exact Electric LLC Page 2 of 2 Quarter 2 of Year 2016 "ll 1 to 20 Workers" L&I account representative T1 / NICHOLE CAROW (360)902-5634 - Email: CAN1235@lni.wa.gov Workplace safety and health Check for any past safety and health violations found on jobsites this business was responsible for. ©Washington State Dept. of Labor & Industries. Use of this site is subject to the laws of the state of Washington. Help us improve https:Hsecure.Ini.wa.gov/verify/Detail.aspx?UBI=602872261&LIC=EXACTEL927RK&SAW= 9/26/2016 ^"�Y,?��"a"`hY�Y" "� w t 9§�'"•rn�� z ;'i �, "� � �9',*�ry`r�zy2'7 S�ro,.%�^� �,�' `•* �'`��°r"'it.�'j"^�tA#�>�a`f b� nit, � a a Intelr 1 • • • •• • • • • • • 11100111 •• -.0.11-24FREFFlin. • • • 1 Project Info Project Address SEATTLE CHOCOLATES Date 6/24/2016 Compliance 1180 ANDOVER PARK WEST For Building Department Use forms do not require a 488 TUKWILA, WA 98065 password to use. a. Lighting fixtures in a building addition may comply as a stand alone project, or they may be Applicant Name: CASE ENGINEERING instructional and calculating cells Location (plan # room #, or ALL) Applicant Address: 19515 NORTH CREEK PKWAY, SUITE 302, BOTHELL WA Applicant Phone: 425-402.9400 are write- 4 __ Project Description 0 New Building O Addition ® Alteration Q Plans Included Lighting Compliance Path Lighting Power Density Calculations 0 Total Building Performance d. If less than 60% of existing fixtures will be replaced, provide total existing lighting Kettage (If Total Building Performance then only LGT-CHK is Lighting Power Allowance 0 Building Area Method 0 Space -By -Space Method Method Selection required to Maximum Allowed Lighting Wattage enable LPA forms Location (plan #, Allowec Interior Lighting System room #, or ALL) Space Type* Watts per ft? Description Retail: Sales area 1.68 Briefly describe lighting Corridor/transition 0.66 system type and features. Food preparation 0.95 Additions and Change of Space Use (C101.4.3 & C101.4.4) © Addition area or Change of Space Use area complies with all applicable provisions as stand alone project o Addition area is combined with existing building lighting systems to demonstrate compliance with all applicable provisions per C101.4.3 Provide Building Area Method (LTG -INT -BLD) or Space -By -Space Method (LTG -INT -SPACE) Compliance Form. Document maximum allowed and proposed (including existing if applicable) lighting wattage of Addition or Change of Use space. Provide applicable lighting controls per C405.2 and commissioning of lighting controls per C405.13. Alterations, Renovations and Repairs (C101.4.3.1) ® 60% or more of luminaires in space replaced Provide Building Area Method (LTG-iNT-BLD) or Space -By -Space Method (LTG -INT -SPACE) Compliance Form. Document maximum allowed wattage within the lighting retrofit space in Maximum Allowed Wattage table and proposed (including existing) lighting wattage in Proposed Wattage table. Retrofit and non -retrofit spaces shall be documented separately using multiple forms. 0 Less than 60% of luminaires in space replaced Provide a separate Space -By -Space Method (LTG -INT -SPACE) Compliance Form for this retrofit area. Document existing total wattage within the lighting retrofit space in cell provided in the Maximum Allowed Wattage table. Document proposed (including existing) lighting wattage in the Proposed Wattage table. j3 Lamp and/or ballast replacement within existing luminaires only -existing total interior building wattage not increased New wiring installed to serve added fixtures and/or fixtures relocated to new circuit Provide applicable manual lighting controls (C405.2.1), occupancy sensors (C405.2.2.2), daylight zone controls (C405.2.2.3), specific application controls (C405.2.3), and commissioning of lighting controls per C405.13 © New or moved lighting panel Provide all applicable lighting controls as noted for New Wiring, automatic time switch controls (C405.2.2.1), and commissioning of lighting controls per C405.13. 13Space is reconfigured - luminaires unchanged or moved only Provide all applicable lighting controls as noted for New Wiring and commissioning of lighting controls per C405.13. Q No changes are being made to the interior lighting and space use not changed. nn- UL..dJ...d C4Md Cnci.nv r•ndl Pn till- C -Me f P? R R3 nvar 3 stories and all R1 Nov 2013 Project Address SEATTLE CHOCOLATES Date 6/24/2016 Lighting Alterations, Renovations & Building Additions For Building Department Use 0 Less than 60% 60% or more 0 Stand alone 0 Addition 4 fixtures replaced fixtures replaced bldg. addition combined w/exist 488 Notes: Applicant Name: CASE ENGINEERING a. Lighting fixtures in a building addition may comply as a stand alone project, or they may be Maximum Allowed Display Lighting Wattage combined with the overall existing bldg lighting to demonstrate compliance. Refer to C101.4.3. Location (plan # room #, or ALL) b. For retrofits and building additions, provide Space Types and gross interior areas in the Allowed Watts per fiz ** Maximum Allowed Lighting table. If a builidng addition LMII comply as combined with the overall 4 existing builidng, include all applicable existing Space Types and gross interior areas. 240 c. Document new fixtures and all existing to remain fixtures in the Proposed Lighting table. 33 d. If less than 60% of existing fixtures will be replaced, provide total existing lighting Kettage 1584 (prior to retrofit) in the space provided in the Maximum Allowed Lighting table. 7 40 Maximum Allowed Lighting Wattage LF7-PENDANT MTD CYLINDER LT Location (plan #, Allowec Gross Interior Watts Allowed room #, or ALL) Space Type* Watts per ft? Area in ff (watts/fe x area) Retail: Sales area 1.68 1450 2436 Corridor/transition 0.66 3500 2310 Food preparation 0.95 98 97 Restroom 0.98 387 379 Electricallmechanical 0.95 98 93 x if (or x If) Retail Display Lighting from LGT•INT-DISPLAY RETAIL DISPLAYS 0.5 W/£t2 Atrium"` EnterHei ht: 93 ExistingLighting Enter Exist. Watts: Retail Display Allowance from LGT-INT-DISPLAY 1025 * Select Table C405.5.2(2) category from drop down menu. *" For atriums, indicate height. AlloKed wattage for first 40 feet is 0.03 W/ft. ht., above 40 feet is 0.02 W/ft. ht. 7P n"l Cn'4 T ;rrlif;no WaffavP Total 5533 v 6340 - --C- --- v v Location (plan #, room #, or ALL) Fixture Description*** Number of Fixtures Watts/ Fixture Watts Proposed LF1A-RECESSED 12' LED 4 122 488 163 Applicant Name: CASE ENGINEERING UNLESS OTHERWISE NOTED Maximum Allowed Display Lighting Wattage LF2-LINE VOLT TRACK WITH 2.5A CL (RETAIL DISPLAY) Location (plan # room #, or ALL) Retail Display Area Type* Allowed Watts per fiz ** LF3-WALL SCONCE INCAN-1 LAMP 4 60 240 LF4-PENDANT MTD INDUSTRIAL LED 33 48 1584 LF6-PENDANT INCANDESCENT 7 40 280 LF7-PENDANT MTD CYLINDER LT 20 18 360 LFS-RECESSED 2x2 TROFFER LED 4 34 136 LF9-RECESSED 2x4 TROFFER LED 4 40 160 Surface Description 1 (If) or # of items x if (or x If) Retail Display Lighting from LGT•INT-DISPLAY RETAIL DISPLAYS 0.5 W/£t2 1800 Total Proposed Watts may not exceea royal wr/oweo Waris ror mrerrur r_ryne"Ly ..-1 -Include existing to remain lighting fixtures and exempt lighting equipment per notes below. Notes: n 1. include ALL proposed osed ! ihti9 fixtures. 0 2For proposed Fixture Description indicate fixture type, lam type (e.9. T 8). number of lampssin the fixture, ture and ballast typee (if included). . For track lighting, list the length of the track (in feet) in addition to the fixture, lamp, and ballast information. 3. For proposed Watts/Fixture, use manufacturer's listed maximum input Kettage of the fixture (not simply the lamp wattage) and other criteria as specified in Section C405.5.1. For line voltage track lighting, list the greater of actual luminaire wattage or length of track multiplied by 50, or as applicable, the Kettage of current limiting devices of the transformer. For low voltage track lighting list the transformer rated wattage. 4. For lighting equipment eligible for exemption per C405.5.1, note exception number and leave Watts/Fixture blank. 5. Document existing to remain fixtures in Proposed Lighting table in the same manner as new fixtures. identify as existing in fixture description. 6. If #NA appears in Retail Display cells, information on LTG-INT-DiSPLAY is incomplete. Interior Lighting Power Allowance COMPLIES State Fnemv Code Comnliance Forms for Commercial Buildinas includina R2 & R3 over 3 stories and Project Info Project Address SEATTLE CHOCOLATES Watts) Fixture Date 6/24/2016 1180 ANDOVER PARK WEST 6 For Building Department Use TUKWILA, WA 98065 163 Applicant Name: CASE ENGINEERING UNLESS OTHERWISE NOTED Maximum Allowed Display Lighting Wattage Project Description Location (plan # room #, or ALL) Retail Display Area Type* Allowed Watts per fiz ** Gross interior Watts Allowec Area in if (watts/fit x area) 0 Zone 1 0 Zone 2 0 Zone 3 0 Zone 4 Retail 1: All unclassified retail display 0.60 875 525 0 Lighting Power Density Calculations 0 Total Building Performance Building Grounds ® Efficacy> 60 IumensiW Controlled by motion sensor 0 Exemption (list) Applies to luminaires > 100 Watts Exterior Lighting Alteration ONO changes are being made to the existing exterior lighting 13 New wiring installed to serve added fixtures and/or fixtures relocated to new circuit W WATTS Provide applicable exterior lighting controls per C405.2.4 and commissioning per Tradable Maximum Allowed Lighting Wattage Base Site Allowance: 750 WIRELESS ACCESS POINT CITY ����i LA Allowed a . * Only retail sales areas that meet the requirements defined in Table Area Area vvaus C405.5.2(2) footnote A may be entered here. Select retail sales areas form drop Total 875 1-52 5 down menu. ** Wattages per Table C405.5.2(2) footnote A. Display Lighting Base Allowance 500 ++ Displa li ht allowance er footn to A calculation. DISE? i0t WATTA�E ALL - AS CALCULATED BY AREA ++ Total Display Allowanc 1025 Proposed Display Lighting Wattage _..... -..a.... ,. .,a.,.u,..J ,ar...-i,.,. F•.,a.,-,...1;nhf;n nor Tnhla r:Gnri ri 9191 fnntnnta A may ha Pntr:rAri hPrP. Location Ian # Display Area* room #, or ALL) Fixture Description Number of Fixtures Watts) Fixture Watts Proposed Retail 1STFLOORPLAN TRACKWITH2.5ACL 6 300 1800 163 ApplicantAddr: 19515 NORTH CREEK PKWAY, SUITE 302, BO UNLESS OTHERWISE NOTED Applicant Phone: 425.402-9400 Project Description Q New Building Q Addition ® Alteration 0 Plans Included Lighting Zone As specified by jurisdiction. Zone 0 Zone 1 0 Zone 2 0 Zone 3 0 Zone 4 selection required to enable LTG -EXT CvTTF- ompliance Option 0 Lighting Power Density Calculations 0 Total Building Performance Building Grounds ® Efficacy> 60 IumensiW Controlled by motion sensor 0 Exemption (list) Applies to luminaires > 100 Watts Exterior Lighting Alteration ONO changes are being made to the existing exterior lighting 13 New wiring installed to serve added fixtures and/or fixtures relocated to new circuit W WATTS Provide applicable exterior lighting controls per C405.2.4 and commissioning per Tradable Maximum Allowed Lighting Wattage Base Site Allowance: 750 WIRELESS ACCESS POINT CITY ����i LA Allowed a . Area (W), perimeter Allowed Watts Tradable Surfaces Surface Description per f? or per If (If) or # of items x if (or x If) Open Sales RETAIL DISPLAYS 0.5 W/£t2 185 93 Main Entry Door ENTRY DOOR 30W/LF door width 18 540 WEATHERPROOF * Select retail sales display area from drop down menu. Total Proposed Wattsl 3.800 Proposed Display Retail 1 Retail 2 Retail 3 Retail 4 Lighting Totals 1800 Notes: 1. Forproposed DisplayFixture Description, indicate fixture type, lamp type (e.g. T-8), numberof lamps in the fixture, and ballast type (if included). For track lighting, list the length of the track (in feet) in addition to the fixture, lamp, and ballast information. 2. For proposed Watts/Fixture, use manufacturer's listed maximum input wattage of the fixture (not simply the lamp wattage) and other criteria as specified in Section C405.5.1. For line voltage track lighting, list the greater of actual luminaire wettage or length of track multiplied by 50, or as applicable, the wattage of current limiting devices or of the transformer. For low voltage track lighting list the transformer rated Kettage. 3. List all display fixtures. r'-1. l' -H.- P -r Ldinn R2 & R3 over 3 Revised Nov 2013 Project Info Project Address: SEATTLE CHOCOLATES Date 6/24/2016 1180 ANDOVER PARK WEST For Building Department Use Open Sales LF5 17 25 TUKWILA, WA 98065 Main Entry Door LF1X Applicant Name: CASE ENGINEERING 163 ApplicantAddr: 19515 NORTH CREEK PKWAY, SUITE 302, BO UNLESS OTHERWISE NOTED Applicant Phone: 425.402-9400 Project Description Q New Building Q Addition ® Alteration 0 Plans Included Lighting Zone As specified by jurisdiction. Zone 0 Zone 1 0 Zone 2 0 Zone 3 0 Zone 4 selection required to enable LTG -EXT CvTTF- ompliance Option 0 Lighting Power Density Calculations 0 Total Building Performance Building Grounds ® Efficacy> 60 IumensiW Controlled by motion sensor 0 Exemption (list) Applies to luminaires > 100 Watts Exterior Lighting Alteration ONO changes are being made to the existing exterior lighting 13 New wiring installed to serve added fixtures and/or fixtures relocated to new circuit W WATTS Provide applicable exterior lighting controls per C405.2.4 and commissioning per Tradable Maximum Allowed Lighting Wattage Base Site Allowance: 750 WIRELESS ACCESS POINT CITY ����i LA Allowed a . Area (W), perimeter Allowed Watts Tradable Surfaces Surface Description per f? or per If (If) or # of items x if (or x If) Open Sales RETAIL DISPLAYS 0.5 W/£t2 185 93 Main Entry Door ENTRY DOOR 30W/LF door width 18 540 WEATHERPROOF Total Allowed Tradable Watts 633 Tradable Proposed Lighting Wattage (use mfgr listed maximum input wattage for luminaire.) Tradable Surface Fixture Description Number of Watts/ Fixtures Fixture Watts Proposed Open Sales LF5 17 25 425 Main Entry Door LF1X 1 163 163 U.O.N. UNLESS OTHERWISE NOTED Total proposed tradable Ketts may not exceed the sum of total alloKed tradable 11 L Total Proposed Tradable Watts 588 make tradable wens comply can be applied to individual non -tradable Non -Tradable Maximum Allowed Lighting Wattage Base Site Allowance Remaining: 750 Non -Tradable Surfaces Allowed atts Surface Description per fe or per If Area (ff), perimeter (If) or # of items Allowed Watts. x ff (or x If) UNDERWRITER'S LABORATORY BUILDING DIVISIO U.O.N. UNLESS OTHERWISE NOTED UTIL UTILITY VA Non -Tradable Proposed Lilthting Wattage Number of Non -Tradable Surface Fixture Description Fixtures Wattsl Fixture Watts Proposed UL UNDERWRITER'S LABORATORY BUILDING DIVISIO U.O.N. UNLESS OTHERWISE NOTED Non -tradable proposed was may not exceed allowd efts for an )ndrvidual Total excess Non -Tradable watts: 0 surface unless the total excess watts for all non -tradable surfaces are less than Site Allowance Balance: B a 750 the remaining site allowance. j _.1 s ATI+ P1�' 132QUIPIED FOR: i''tLChanIcal ❑ Elcotllca) jUmbing S Piping C;iY of Tukwila sI "_n- ,,%"C; DIVISION REVISlONS i"o res-�1r3��;S Slt�?91i t3'� trt�dL la lht� 4t:�?�9fP�! r , ~ 1C 1"ria?°;i • not approval n ,a SUllding Division, I ,r .-�:. t:*viii require a ne4�� plan subrrlittal r U I ii -y m�;uda additional plan roview fec' s• r Pi'_is subject to errors and orni si®ns. of conisiruclion documents does net rttflhorize Vqt.^ -; •..7- . ado ted codsa or ordinance. Re ' � � cert Of EPrr %.,V,' J Fold and cerldiliolT Icnowied ed: �y: �,C� Date: City Of Tulwma BUILDING DIVISION 1St DRAWING INDEX EO.1 LEGEND AND SCHEDULES EO.2 RISER DIAGRAM & PANEL SCHEDULES EO.3 SCHEDULES AND DETAILS ED1.0 DEMOLITION PLAN E1.0 ELECTRICAL POWER FLOOR PLAN E2.0 LIGHTING FLOOR PLAN E2.1 LIGHTING PARTIAL PLAN -WALKWAY El 9.0 EMERGENCY LIGHTING FLOOR PLAN EL2.1 EMERGENCY LIGHTING FLOOR PLAN ELECTRICAL LEGEND POWER RECEPTACLES & OUTLETS K) SINGLE RECEPTACLE 14) DUPLEX RECEPTACLE DOUBLE DUPLEX RECEPTACLE DUPLEX GFCI RECEPTACLE DOUBLE DUPLEX GFCI RECEPTACLE 4�t DUPLEX RECEPTACLE MOUNTED IN CEILING 0 DOUBLE DUPLEX RECEPTACLE MOUNTED IN CEILING WD DUPLEX RECEPTACLE MOUNTED +4"O.C. ABOVE COUNTER OR BACKSPLASH, WHEN PRESENT (U.O.N.) DOUBLE DUPLEX RECEPTACLE MOUNTED +4"O.C. ABOVE COUNTER OR BACKSPLASH, WHEN PRESENT (U.O.N.) i� DUPLEX GFCI RECEPTACLE MOUNTED +4"O.C. ABOVE COUNTER OR BACKSPLASH, WHEN PRESENT (U.O.N.) DOUBLE DUPLEX GFCI RECEPTACLE MOUNTED +4"O.C. ABOVE COUNTER OR BACKSPLASH, WHEN PRESENT (U.O.N.) *WP GFCI RECEPTACLE WITH WEATHERPROOF WHILE -IN -USE COVER �@ SINGLE SPECIAL PURPOSE RECEPTACLE Q JUNCTION BOX WITH BLANK COVER TELE/COMMUNICATIONS SYSTEM DEVICES TELEPHONE ® SINGLE GANG TELEPHONE/DATA OPENING TTB TELEPHONE TERMINAL BOARD - 3/4" FIRE RESISTANT PLYWOOD, 8' HIGH x LENGTH SHOWN ON PLAN NOTES AND MISCELLANEOUS SYMBOLS FLAGNOTE - IDENTIFIES A SPECIFIC ITEM ON A DRAWING. 3 COORESPONDS TO A SCHEDULE IN THE ELECTRICAL SET THAT EXPLAINS DETAILS OR FEATURES OF THAT ITEM. FF -3 MECHANICAL FLAG - DEFINES MECHANICAL EQUIPMENT AND COORESPONDS TO DESIGNATIONS IN MECHANICAL PLANS AND SCHEDULES. COORESPONDS MECHANICAL CONNECTION SCHEDULE IN THE ELECTRICAL SET. REVISION CLOUD AND FLAG - CLOUD SURROUNDS INFORMATION THAT HAS BEEN REVISED. FLAG IDENTIFIES 1 THE REVISION IN WHICH THE CHANGES WERE MADE. ODETAIL NUMBER - APPEARS IN FRONT OF A TITLE ON DRAWINGS WITH MORE THAN ONE ILLUSTRATION. 3 IDENTIFICATION SYMBOL - CROSS REFERENCES INFORMATION E1.1 IN ONE AREA WITH A DETAIL (TOP #) AND SHEET (BOTTOM #) IN ANOTHER IN THE ELECTRICAL SET. NOTE: ALL FIXTURES AND EQUIPMENT SHOWN ON PLANS IN STANDARD (HEAVY) LINE WEIGHT ARE NEW OR RELOCATED WORK. FIXTURES AND EQUIPMENT SHOWN IN LIGHT LINE WEIGHT WITH (E) NEXT TO THEM INDICATE EXISTING TO REMAIN. SYMBOLS SHOWN AS DASHED INDICATE ITEMS TO BE REMOVED OR DEMOLISHED. THIS APPLIES UNLESS NOTED OTHERWISE ON PLANS. SERVICE GEAR - AS SHOWN ON PLANS diiiiii CIRCUIT BREAKER PANELBOARD G LOAD CENTER mg-= LIGHTING CONTROL PANEL EXISTING PANELBOARD TO REMAIN t� TERMINAL CABINET SWITCHBOARD OR MOTOR CONTROL CENTER, SIZE AS SHOWN ON PLANS FT DRY TYPE TRANSFORMER (SEE NOTES & RISER DIAGRAM FOR SIZE) CONDUITS AND CIRCUITING WIRING LOCATED IN CEILING OR WALL - - - - WIRING CONCEALED UNDER FLOOR OR UNDERGROUND �- CONDUIT HOME -RUN T.' NDUIT TURNS & CHANGES ELEVATION AT THIS POINT -•- ISOLATED GROUND WIRE !+ GROUND WIRE o CONDUIT STUB -UP -� 5-- CONDUIT BREAK 3 CONDUIT CONTINUES ELSEWHERE (NOTED ON PLAN) �E CONDUIT/EQUIPMENT TO BE REMOVED EQUIPMENT CONNECTIONS & CONTROLS ® EQUIPMENT CONNECTION 4 MOTOR CONNECTION FAN CONNECTION QI DISCONNECT SWITCH FUSED DISCONNECT SWITCH SM MOTOR RATED SWITCH LIGHT FIXTURES & CONTROLS NOTE: LIGHTING FIXTURE SYMBOLS SHOW LENGTH, MOUNTING & EMERGENCY EGRESS INFORMATION ONLY. REFER TO FIXTURE DESIGNATIONS & LIGHTING FIXTURE SCHEDULE FOR LAMP TYPE & OTHER FIXTURE SPECIFICS. O SURFACE CEILING MOUNTED DOWNLIGHT ❑ PENDANT MOUNTED FIXTURE OR CHANDELIER SINGLE P0 SOURCE WALL MOUNTED FIXTURE POINT 44 ® LINEAR FIXTURE (NARROW BODY) 1---0I LINEAR STRIP FIXTURE LINEAR INDUSTRIAL STRIP FIXTURE -7--7-0 TRACK LIGHT (LENGTH AS SHOWN ON PLAN) ® SURFACE LINEAR EMERGENCY EGRESS FIXTURE ®® DIRECTIONAL EXIT SIGN (ARROWS INDICATE ONE OR TWO SIDES AND DIRECTION INDICATED) EMERGENCY EXIT SIGN WITH DUAL PATHWAY HEADS `:P DUAL HEAD EMERGENCY EGRESS FIXTURE S VACANCY SENSOR LIGHT SWITCH S LOW VOLTAGE SWITCH CONTROLLED BY ROOM SENSOR S LIGHT SWITCH SUBSCRIPTS ARE AS FOLLOWS: b R1 LV = LOW VOLTAGE, D = DIMMING b = LOWER CASE LETTER CORRESPONDS TO LETTER AT FIXTURES TO BE CONTROLLED R# = RELAY # IN LIGHTING CONTROL PANEL S# = SENSOR ZONE Q CEILING MOUNTED VACANCY SENSOR os CEILING MOUNTED OCCUPANCY SENSOR Pc PHOTOCELL LIGHT SENSOR ABBREVIATIONS A (200A) (AFTER A NUMBER) = AMPS AF(200AF) (AFTER A NUMBER) = FUSE SIZE IN AMPS AFF ABOVE FINISHED FLOOR AHJ AUTHORITY HAVING JURISDICTION AL ALUMINUM ATS AUTOMATIC TRANSFER SWITCH BKR BREAKER C CONDUIT CKT CIRCUIT CL CENTERLINE CLG CEILING C.O. CONDUIT ONLY CRP CONTROL RELAY PANEL CU COPPER DIA DIAMETER DISC DISCONNECT DISP DISPOSER DF DRINKING FOUNTAIN DW DISHWASHER E.C. ELECTRICAL CONTRACTOR ECB ENCLOSED CIRCUIT BREAKER (E) EXISTING (USED AS SYMBOL DESIGNATION) EMIT ELECTRICAL METALLIC TUBING EXTG EXISTING (USED AS ABBREVIATION IN TEXT) FAAP FIRE ALARM ANNUNCIATOR PANEL FACP FIRE ALARM CONTROL PANEL FLR FLOOR F.O.I.C. FURNISHED BY OTHERS, INSTALLED BY ELECTRICAL CONTRACTOR FSD FIRE SMOKE DAMPER FLIT FUTURE GEN GENERATOR GFCI GROUND FAULT CIRCUIT INTERRUPTER GND GROUND • ^" "' HH HANDHOLE HTR HEATER HWT HOT WATER TANK HOA HAND-OFF-AUTOy, kCMIL THOUSANDS OF CIRCULAR MILS KVA 1000 VOLT AMPERES KW 1000 WATTS LCP LIGHTING CONTROL PANEL KAY" LT LIGHT LTS(LTG) LIGHTS (LIGHTING) LV LOW VOLTAGE MCB MAIN CIRCUIT BREAKER MECH MECHANICAL MH MANHOLE MLO MAIN LUGS ONLY MSC MULTI -SCENE CONTROLLER N3R NEMA 3R NIC NOT iN CONTRACT NREC NON-RESIDENTIAL ENERGY CODE OC ON CENTER OH. OVERHEAD OS OCCUPANCY SENSOR PC PHOTOCELL PNL PANELBOARD PIV POST INDICATOR VALVE P.O.S. POINT OF SALE PP POWER POLE/POWER PACK (SEE PLAN LOCATION) PSE PUGET SOUND ENERGY PUD PUBLIC UTILITY DISTRICT PV PHOTOVOLTAIC REC RECEPTACLE(S) REF REFRIGERATOR (R) RELOCATED EXISTING RQMTS REQUIREMENTS SCL SEATTLE CITY LIGHT SPD SURGE PROTECTIVE DEVICE SQ SQUARE REVIEWED OR SW SWITCH COMPLIANCE Wil TBD TO BE DETERMINED NFPA 70 " NEC II10400181?1aION1111111»:Li7_1:t TYP UC UG TYPICAL UNDER COUNTER UNDERGROUND JUL 19 2016 Ulf cit•a ®t 1 OWIIa UL UNDERWRITER'S LABORATORY BUILDING DIVISIO U.O.N. UNLESS OTHERWISE NOTED UTIL UTILITY VA VOLT AMPERES VFD VARIABLE FREQUENCY DRIVE VS VACANCY SENSOR W WATTS 1i 1d e Rtm.�'�r�.I ;t4....n WAP WIRELESS ACCESS POINT CITY ����i LA WC WATER COOLER JUN 27 216 W/D WASHER/DRYER W/0 WITHOUT PERMIT CENTER WP WEATHERPROOF XFMR TRANSFORMER r �ll SEATTLE CHOCOLATES 1180 ANDOVER PARK WEST TUKWILA, WA 98065 SEATTLE CHOCOLATES CHOCOLATE FACTORY TOUR 1180 ANDOVER PARK WEST TUKWILA, WA 98065 CASJ__-� ENGINEERING Consulting Engineers 19515 North Creek Parkway, Suite 302 Bothell, Washington 98011 Phone: 425-402-9400 Fax: 425-402-9402 C-16178 EL S ELECTRICAL LEGEND AND SCHEDULES 0 DATE DESCRIPTION :::: * %..................... ..................:... ti l :............................................................ I�1 FLAG NOTES 1� EXISTING XFMR TO BE RELOCATED FROM UPS ROOM TO UTILITY ROOM 106. SEE FLAG NOTES ON SHEET E1.0. PANEL TO BE RELOCATED FROM UPS ROOM TO UTILITY ROOM 106 AND RELABELED C1. SEE FLAG NOTES ON SHEET E1.0. PROVIDE EQUIPMENT, MATERIALS, AND LABOR, TO EXTEND EXISTING CONDUIT & CONDUCTOR TO EXISTING XFMR NEW LOCATION. EXISTING PARTIAL RISER DIAGRAM NO SCALE MECHANICAL EQUIPMENT CONNECTION SCHEDULE TAG DESCRIPTION HP /KW IVA VOLTS / MCA FUSE DISC. STARTER CIRCUIT FEEDER SIZE TAG REMARKS NOTES INTERIOR/EXTERIOR PHASE RECESSED 12' LINEAR LED LENGTHS AS SHOWN ON PROJECT PLANS. (MOCP) SWITCH 850 LUMENS PER FT80 CRI 3000K. PROVIDE 0-10V DIMMING CONTROL PER FT VIA PHOTOSENSOR. EWH-1 WATER HEATER 3 KW 208/1 LED - - - C1-2,4 3/4"C., 3#12, 1#12G. EWH-1 LINE VOLTAGE TRACK WITH LED TRACK HEAD EVERY 2.5'. 5A CURRENT LED EWH-2 INSTA HOT 8.2 KW 208/1 - - - C1-6,8 3/4"C., 3#8, 1#10G. EWH-2 LED 18 LF5 LINEAR LED WITH DMX CONTROLLER (EXTERIOR DISPLAY) LED 100 LF6 PENDANT MOUNTED INCANDESCENT. 1-40W E27 40 LF7 PENDANT MOUNTED CYLINDER LIGHT, LED, 1250 LUMENS, 3000K LED 18 LF8 EF -1 WOMEN'S RR FAN 1/4 HP 120/1 RECESSED 2x4 LED TROFFER - - - C1-10 3/4"C., 2#12, 1#12G. EF -1 WITH TWO ROTATABLE EMERGENCY EGRESS EF -2 MEN'S RR FAN 1/4 HP 120/1 50W PAR36 - - - C1-10 3/4"C., 2#12, 1#12G. EF -2 GENERAL EQUIPMENT CONNECTION SCHEDULE NOTES (APPLIES TO ALL EQUIPMENT LISTED IN SCHEDULE) A. THE ABOVE INFORMATION IS FOR A SPECIFIC MANUFACTURER. THE ACTUAL MANUFACTURER FOR THE EQUIPMENT MAY BE DIFFERENT. COORDINATE 'NITH MECHANICAL EQUIPMENT SUBMITTALS FOR ACTUAL LOADS, CIRCUIT AMPACITY AND OVERCURRENT PROTECTION REQUIREMENTS PRIOR TO ELECTRICAL ROUGH -IN. B. LOCATE ALL DISCONNECTING MEANS PER NEC AND AHJ REQUIREMENTS. STARTERS ARE SEPARATELY MOUNTED UNLESS OTHERWISE NOTED. C. ABBREVIATIONS: HRS: HORSEPOWER RATED MOTOR DISCONNECT SWITCH WITH OVERLOAD PROTECTION, 16 -AMP MINIMUM, RED PILOT LIGHT. PROVIDE 1 -POLE OR 2 -POLE AS REQUIRED. Sm: MOTOR RATED TOGGLE SWITCH. TS: TOGGLE SWITCH, 16 -AMP MINIMUM, RED PILOT LIGHT. PROVIDE 1 -POLE OR 2 -POLE AS REQUIRED. D. ALL DISCONNECTS ARE 3 POLE UNLESS NOTED OTHERWISE. LEGEND NOTES (:2K)EXISTING FEEDER SIZE IN AMPS --':: PARTIAL SHADING IN LIGHT LINES INDICATES EXISTING EQUIPMENT THAT HAS BEEN MODIFIED IN THIS CONTRACT. X X X CONDUIT / EQUIPMENT TO BE REMOVED. ALL PANELS ARE EXISTING UNLESS OTHERWISE NOTED. LIGHTING FIXTURE SCHEDULE WATTS/ TYPE DESCRIPTION LAMP FIXT INTERIOR/EXTERIOR LF1A RECESSED 12' LINEAR LED LENGTHS AS SHOWN ON PROJECT PLANS. LED 122 850 LUMENS PER FT80 CRI 3000K. PROVIDE 0-10V DIMMING CONTROL PER FT VIA PHOTOSENSOR. LF1X SIMILAR TO LF1A EXCEPT 16' IN LENGTH AND WITH 1000 LUMEN BATTERY LED 163 BACK UP FRONT, MIDDLE AND END SECTION. PER FT LF2 LINE VOLTAGE TRACK WITH LED TRACK HEAD EVERY 2.5'. 5A CURRENT LED 600 LIMITER PER POWER FEED. LF3 WALL SCONCE, INCANDESCENT 1-GOW A19 60 LF4 PENDANT INDUSTRIAL, LED WITH 0-10V DIMMING CONTROL. LED 18 LF5 LINEAR LED WITH DMX CONTROLLER (EXTERIOR DISPLAY) LED 100 LF6 PENDANT MOUNTED INCANDESCENT. 1-40W E27 40 LF7 PENDANT MOUNTED CYLINDER LIGHT, LED, 1250 LUMENS, 3000K LED 18 LF8 RECESSED 2x2 LED TROFFER LED 34 LF9 RECESSED 2x4 LED TROFFER LED 40 X1 EXIT SIGN WITH EMERGENCY EGRESS PATHWAY LIGHT LED 15 WITH TWO ROTATABLE EMERGENCY EGRESS 50W PAR36 B1 EMERGENCY EGRESS PATHWAY LIGHTS WITH BATTERY BACK UP 50W PAR36 15 Q3. ` A 4w. k L�, JUL 19 2016 City of -Tukwila, BUILDING DIVISION CITY Oa= T Ulk- ILA JUN 27 2016 PERMIT CENTER 7f SEATTLE CHOCOLATES 1180 ANDOVER PARK WEST TUKWILA, WA 98065 SEATTLE CHOCOLATES CHOCOLATE FACTORY TOUR 1180 ANDOVER PARK WEST TUKWILA, WA 98065 Consulting Electrical Engineers 19515 North Creek Parkway, Suite 302 Bothell, Washington 98011 Phone: 425-402-9400 Fax: 425-402-9402 C-16178 RISER DIAGRAM AND PANEL SCHEDULES D DATE DESCRIPTION IIx BEFORE PANEL'UPS1' AFTER PANEL'C1'(FORMERLY AFTER PANEL'1H1' PROJECTNAME Seattle Chocolate PROJECT NA ME Seattle Chocolate PROJECT#: 16178 LOCATION: LOCATION: FED FROM: FED FROM: PROJECT#: 16178 LOCATION: LOCATION: FED FROM: FED FRDM: H-4 VIA T PANE- DESCRIPTION UNUSABLESPACE NOTE CKT CIRCUIT NAME NO. CB SIZE OIAMPI P R LOAD(KVA) H M L K O TOTAL PANEL DESCRIPTION 1 1 LIGHTS A 20 1 11 FEEDER AMPS : 125 L- L VOLTS : 208 PANELAMPS : 200 1 3 LIGHTS B 20 1 B L- N VOLTS : 120 PHASE: 3 FEEDER AMPS : 200 1 5 LIGHTS C 20 1 UNUSABLESPACE C L- L VOLTS : 477 1 7 LIGHTS A 20 1 4 1 LTS-TRACK RETAIL L- N VOLTS : 240 1 9 LIGHTS B 20 1 120 4 PHASE: 3 1 11 LIGHTS C 20 1 PHASE : 3 WIRE: 4 1 13 EXIT SIGNS A 20 1 0.60 WIRE: 4 4 1 15 DSTM (EM LIGHTING) B 20 1 1.00 1.00 20 1 1 17 LIGHTS C 20 1 B - - 1 2 19 PANE_ C1 VIA 45KVA XFMR A 60 3 rQ90 5.66 2.00 8.56 M.L.O. MAIN CB 0.90 - B - - Q54 1.50 1.00 1.00 4.04 13 REC - C - - 1.62 4.16 0.60 6.38 FLUSH SURFACE 1 EMERGENCY, EXIT AND OUTSIDE LIGHTS r25 A 30 3 0.54 - SURFACE X X 125A - B - - 1110.54 - ISO GND 0.54 FLUSH C - - 20 1 FEED THRU SURFACE ISO GND X 4 21 SPARE B 20 1 4 23 SPARE C 20 1 HEAT KVA FEED-THRU Ci - - 25 SPACE ONLY A - 1 A 20 LOAD SUM MARY LIGHTING KVA 27 SPACE ONLY B - 1 KITCHEN KVA LOAD SUM MARY C 20 29 SPACE ONLY C - 1 2 LIGHTS A 20 1 A 20 4 LIGHTS B 20 1 10 COMP B HEAT KVA REC KVA : 3.06 1 2 LIGHTS A 20 1 1 4 LIGHTS B 20 1 8 LIGHTS A HEAT KVA 11.32 1 6 LIGHTS C 20 1 B 20 MOTOR KVA : 1.00 1 8 LIGHTS A 20 1 20 B LIGHTING KVA : 8.50 1 10 LIGHTS B 20 1P 1 KITCHEN KVA - 1 12 LIGHTS C 20 1 1.00 3.60 2,3,4 OTHER KVA 26 SPACEONLY 1 14 LIGHTS A 20 1 1.50 1.50 PHASEA KVA 10.56 1 16 LIGHTS B 20 1 1 18 LIGHTS C 20 1 F 4.16 OTHER KVA AMPS : 44 1 20 LIGHTS A 20 1 4.16 4.16 PHASE BKVA 5.04 1 22 LIGHTS B 20 1 1.00 AMPS : 21 1 24 LIGHTS C 20 1 1 0 .18 PHASECKVA 8.28 3 26 LTS-RETAIL AND SUPPORT A 20 1 2.00 2.00 AMPS : 35 3 28 LTS-MEZZAINE B 20 1 1.00 r 1.00 1 3 30 LTS-EXTERIOR C 20 1 1.90 1.90 20 1 r I PHASECKVA : 6.38 4 20 SPARE CONNECTED LOAD 20 3 AMPS : 53 KVA 23.88 B - - AMPS : 29 24 - C - - DEMAND LOAD 26 SPACE ONLY A - 1 KVA 26.26 28 SPACE ONLY B - 1 AMPS : 32 NOTES/REMARKS : 1. EXISTING TO REMAIN 2. CIRCUIT MODIFIED BY WORK 3. PROVIDE NEW CIRCUIT BREAKER 30 SPACEONLY DEMAND / DIVERSITY FACTORS LOAD DESCRIPTION R RECEPTACLES - TO 10KVA REMAINING OVER 10KVA H HEATING M MOTORS LM LARGESTMOTOR L LIGHTING K KITCHEN O OTHER - DEMAND 100% = 50% _ 100% = 100% _ 125% = 125% = 65% _ 100% _ 3.06 11.32 1.25 10.63 BEFORE PANEL'UPS1' AFTER PANEL'C1'(FORMERLY UPS -1) PROJECTNAME Seattle Chocolate PROJECT NAME Seattle Chocolate PROJECT#: 16178 LOCATION: LOCATION: FED FROM: FED FROM: H-4 VIA T PROJECT#: 16178 LOCATION: CB SIZE I OIAMPI PI R FED FRDM: H-4 VIA T PANE- DESCRIPTION UNUSABLESPACE 1 LIGHTS NOTE CKT CIRCUIT NAME NO. CB SIZE bITM9 P R LOAD(KVA) H M L K O TOTAL PANEL DESCRIPTION 3 LIGHTS UNUSABLESPACE A 11 FEEDER AMPS : 125 L- L VOLTS : 208 UNUSABLESPACE C FEEDER AMPS : 200 1 COMP PANEL AMPS : 225 20 UNUSABLESPACE B L- N VOLTS : 120 PHASE: 3 L- L VOLTS : 477 7 LIGHTS A FEEDER AMPS : 125 UNUSABLESPACE C 7 TELE LOWER EQUIPMENT A 20 1 9 LIGHTS B 20 1 L- L V OLTS : 208 4 1 LTS-TRACK RETAIL A20 C 1 1 1.00 1.00 L - N VOLTS : 120 4 3 LTS-TRACK FLEX B 20 1 M.L.O. 1.00 1.00 PHASE : 3 4 5 LTS-LTS REST ROOM AND SEATING C 20 1 X 0.60 0.60 WIRE: 4 4 7 LTS-TRACK M EZZAINE A 20 1 A 1.00 1.00 20 1 4 9 SPARE B 20 1 B - - 1 4 11 REC C 20 1 0.90 - 0.90 3 13 REC A 20 1 0.72 30 0.72 M.L.O. SURFACE 3 15 REC B 20 1 0.54 - 0.54 MAIN CB X 125A 3 17 REC C 20 1110.54 - 0.54 FLUSH 4 19 SPARE A 20 1 SURFACE ISO GND X 4 21 SPARE B 20 1 4 23 SPARE C 20 1 HEAT KVA FEED-THRU Ci - - 25 SPACE ONLY A - 1 A 20 LOAD SUM MARY LIGHTING KVA 27 SPACE ONLY B - 1 KITCHEN KVA 6 COMP C 20 29 SPACE ONLY C - 1 2 LIGHTS A 20 1 A 20 4 LIGHTS B 20 1 10 COMP B HEAT KVA 1 6 LIGHTS C LOAD SUM MARY 1 C 20 MOTOR KVA 8 LIGHTS A 20 1 20 3 LIGHTING KVA 10 LIGHTS B 20 1 - RECKVA 3.06 AMPS: UNUSA BLE SPACE (MIN CIRCUIT BREA KER) A 125 3 C 20 B - - OTHER KVA 20 DUCT HEATER 14 LIGHTS HEAT KVA : 11.32 1 C - - 16 LIGHTS B 20 MOTOR KVA : LIGHTING KVA 1.00 3.60 2,3,4 2 EWH-1 A 20 2 1.50 1.50 26 SPACEONLY 4 - B 20 11 1.50 1.50 KITCHEN KVA 20 LIGHTS 3 6 EWH-2 C 50 2 PHASE KVA 4.16 F 4.16 OTHER KVA 20 1 8 - A - - 24 LIGHTS C 20 1 4.16 4.16 26 SPACEONLY A 4 10 EF -1, EF -2 Bj 20 1 1.00 '-1 00 PHASEA KVA 8.56 3 F 12 REC C5 1 1 0 .18 0.18 AMPS : 71 1,3 '-1 4 WATER FOUNTAIN REC A 15 1 0.18 r0.18 1 PHASE B KVA 4.04 16 SPACE ONLY B 20 1 KVA E IAMPS : 34 18 SPACEONLY C 20 1 r I PHASECKVA : 6.38 4 20 SPARE A 20 3 AMPS : 53 KVA 22 B - - NOTES/REM ARKS : 1. EXISTING TO REMAIN 2. CIRCUIT MODIFIED BY WORK 3. PROVIDE NEW CIRCUIT BREAKER 24 - C - - 26 SPACE ONLY A - 1 CONNECTED LOAD 28 SPACE ONLY B - 1 KVA 18.98 30 SPACEONLY C - 1 AMPS : 53 DEMAND LOAD KVA : 20.13 AMPS : 56 NOTES/REMARKS : 1. PROVIDEGFCI CIRCUIT BREAKER 2. PROVIDE LOCKABLE CIRCUIT BREAKER PER NEC 110.25. 3. PROVIDE NEW CIRCUIT BREAKER 4. CIRCUIT MODIFIED BY WORK DEMAND/ DIVERSITY FACTORS LOAD DESCRIPTION R RECEPTACLES -TO10KVA RBMAINING OVER 10KVA H HEATING M MOTORS LM LARGEST MOTOR L LIGHTING K KITCHEN 0 OTHER DEMAND 100% = 50% _ 100% = 100% _ 125% = 125% = 65% _ 100% _ 3.06 11.32 1.25 4.50 BEFORE PANEL'UPS1' BEFORE PANEL'H1' PROJECTNAME Seattle Chocolate PROJECT#: 16178 LOCATION: LOCATION: FED FROM: FED FROM: H-4 VIA T NOTE CKT CIRCUIT NAME NO. CB SIZE I OIAMPI PI R LOAD(KVA) H M L K 0 TOTAL PANE- DESCRIPTION UNUSABLESPACE 1 LIGHTS A 20 1 PANEL AMPS : 225 PANELAMPS : 200 B 3 LIGHTS B 20 11 FEEDER AMPS : 125 L- L VOLTS : 208 UNUSABLESPACE C FEEDER AMPS : 200 1 COMP 5 LIGHTS C 20 1 L- N VOLTS : 120 PHASE: 3 L- L VOLTS : 477 7 LIGHTS A 20 1 L- N VOLTS : 240 7 TELE LOWER EQUIPMENT A 20 1 9 LIGHTS B 20 1 1 PHASE: 3 11 LIGHTS C 20 1 WIRE : 4 13 PANEL UPS2 13 EXIT SIGNS A 20 1 M.L.O. 15 DSTM (EM LIGHTING) B 20 1 MAIN CB X 17 LIGHTS C 20 1 FLUSH 19 PANEL UPS1 VIA XFMR A 60 3 20 1 M.L.O. SURFACE X 21 B - - 1 MAIN CB ISO GND 23 - C - - FLUSH 25 SPACE ONLY 25 EMERGENCY, EXIT A ND OUTSIDE LIGHTS A 30 31 SURFACE X - 1 27 - B - - C - ISO GND 29 C - FEED-THRU REC KVA UNUSA BLE SPACE (MIN CIRCUIT BREAKER) A 125 3 B - - HEAT KVA - Ci - - MOTOR KVA 2 COMP A 20 LOAD SUM MARY LIGHTING KVA 4 COMP B 20 1 KITCHEN KVA 6 COMP C 20 1 REC KVA OTHER KVA 2 LIGHTS A 20 1 A 20 4 LIGHTS B 20 1 10 COMP B HEAT KVA 1 6 LIGHTS C 20 1 C 20 MOTOR KVA 8 LIGHTS A 20 1 20 3 LIGHTING KVA 10 LIGHTS B 20 1 - KITCHEN KVA AMPS: 12 LIGHTS C 20 1 OTHER KVA 20 DUCT HEATER 14 LIGHTS A 20 1 AMPS 22 - B - 16 LIGHTS B 20 1 PHASEA KVA 26 SPACEONLY 18 LIGHTS C 20 11 CONNECTED LOAD AMPS B 20 LIGHTS A 20 1 KVA AMPS 30 SPACE ONLY C - 1 PHASE KVA 22 LIGHTS B 20 1 DEMAND LOAD AMPS PHASECKVA 24 LIGHTS C 20 1 26 SPACEONLY A 1 AMPS 28 SPACEONLY B 1 DEMAND/ DIVERSITY FACTORS LOAD DESCRIPTION R RECEPTACLES - TO 10KVA REMAINING OVER 10KVA H HEATING M MOTORS LM LARGEST MOTOR L LIGHTING K KITCHEN 0 OTHER DEMAND 100% _ 50% _ 100% _ 100% _ 125% _ 125% _ 65% _ 100 = 30 SPACE ONLY C 1 CONNECTED LOAD KVA AMPS EEAMPS DEMA ND LOAD KVA NOTES/REM ARKS : 1. EXISTING TO REMAIN 2. CIRCUIT MODIFIED BY WORK 3. PROVIDE NEW CIRCUIT BREAKER DEM AND /DIVERSITY FACTORS LOAD DESCRIPTION R RECEPTACLES - TO 10KVA REMAINING OVER 10KVA H HEATING M MOTORS LM LA RGEST MOTOR L LIGHTING K KITCHEN O OTHER DEMAND 100% _ 50% _ 100% _ 100% _ 125% _ 125% _ 65% _ 100% _ BEFORE PANEL'UPS1' DEMO PROJECT NAME Seattle Chocolate PROJECT #: 16178 LOCATION: FED FROM: H-4 VIA T NOTE CKT CIRCUIT NAME NO. CB SIZE 9 Amp P R LOAD(KVA) H M L K 0 TOTAL PANEL DESCRIPTION UNUSABLESPACE A PANEL AMPS : 225 UNUSABLESPACE B FEEDER AMPS : 125 L- L VOLTS : 208 UNUSABLESPACE C 1 COMP A 20.11 L- N VOLTS : 120 PHASE: 3 3 COMP B 20 1 5 TELE LOWER EQUIPMENT C 20 1 WIRE : 4 7 TELE LOWER EQUIPMENT A 20 1 9 SPARE B 20 1 11 TELE LOWER EQUIPMENT C 20 1 13 PANEL UPS2 A 100 3 M.L.O. 15 - B - MAIN CB X 125A 17 C - FLUSH 19 RETAIL COMPS A 20 1 SURFACE X 21 RETAIL COMPS B 20 1 ISO GND 23 RETAIL COMPS C 20 1 FEED-THRU 25 SPACE ONLY A - 1 27 SPACE ONLY B - 1 29 SPACE ONLY C - 1 LOAD SUM MARY REC KVA UNUSA BLE SPACE (MIN CIRCUIT BREAKER) A 125 3 B - - HEAT KVA - Ci - - MOTOR KVA 2 COMP A 20 1 LIGHTING KVA 4 COMP B 20 1 KITCHEN KVA 6 COMP C 20 1 OTHER KVA 8 COMP A 20 1 10 COMP B 20 1 PHASEA KVA 12 COMP C 20 1 AMPS 14 DUCT HEATER A 20 3 PHASE B KVA 16 - B - - AMPS: 18 - C - - PHASECKVA 20 DUCT HEATER A 20 31 1 AMPS 22 - B - 24 - C - - 26 SPACEONLY A - 1 CONNECTED LOAD 28 SPACEONLY B - 1 KVA AMPS 30 SPACE ONLY C - 1 DEMAND LOAD KVA : AMPS: NOTES/REMARKS : 1. 2. 3. DEMAND/ DIVERSITY FACTORS LOAD DESCRIPTION R RECEPTACLES - TO 10KVA REMAINING OVER 10KVA H HEATING M MOTORS LM LARGEST MOTOR L LIGHTING K KITCHEN 0 OTHER DEMAND 100% _ 50% _ 100% _ 100% _ 125% _ 125% _ 65% _ 100 = SEATTLE CHOCOLATES 1180 ANDOVER PARK WEST TUKWILA, WA 98065 SEATTLE CHOCOLATES CHOCOLATE FACTORY TOUR 1180 ANDOVER PARK WEST TUKWILA, WA 98065 ENGINEERING ��r r Consulting Electrical Engineers 19515 N h C JUL 19 2016 ort reek Parkway, Sulte 302 Bothell, Washington 98011 Phone: 425-402-9400 Fax: 425-402-9402 C-16178 SCHEDULES AND DETAILS r �90E UCSCRIPTION City ®1 g T ! ,,^^,■'' ��VY� I ............................................................................................ BUILDING DIVISION , ............................................................................................ .......................................... CITE' OF= i �, aav' JUN 2'7 2016 PERMIT" CENTER ) 'ILITY CESS of 1' I I I j 1) MENS ROOM I f 105 I it fl DEMOLISH ALL EXISTING LIGHT FIXTURES, RECEPTACLE, EQUIPMENTS, AND MATERIALS WITHIN THE PROJECT AREA AS REQUIRED TO FACILITATE THE NEW CONSTRUCTION, WOMANS ROOM 10� XFMR SECO�DARY SIDE DISCONNECT RETAIL -SALES FLOOR 111 FLEX SPACE 110 FACTORY ACCESS 108 NORTH GENERAL NOTES 1 ST FLOOR ELECTRICAL DE OLITIO PLAN CIRCUIT NUMBERS SHOWN REFER TO PANEL C1 UNLESS OTHERWISE NOTED. SCALE: 1/4" = 1'-0" FLAG NOTES EXISTING 45 KVA TRANSFORMER TO BE RELOCATED FROM UPS ROOM TO UTILITY ROOM. RELABEL AS TC1. EXISTING PANEL TO BE RELOCATED FROM UPS ROOM TO UTILITY ROOM. EQUIPMENT TO BE DEMOLISHED. DEMOLISH ALL WIRING ASSOCIATED WITH UNUSED EXISTING PANELS UPS1 & UPS2 AND ASSOCIATED DISCONNECTS. (ALL EXISTING CIRCUITING IN UPS1 & UPS2 HAVE BEEN ABANDONED OR WILL BE DEMOLISHED) SEATTLE CHOCOLATES 1180 ANDOVER PARK WEST TUKWILA, WA 98065 SEATTLE CHOCOLATES CHOCOLATE FACTORY TOUR 1180 ANDOVER PARK WEST TU KW I LA, WA 98065 _� ► Consulting Electrical Engineers 19515 North Creek Parkway, Suite 302 1( Bothell, Washington 98011 one: 425-402-9400 Fax: 425-402-9402 C-16178 L JUL 19 2016 III AWAX 3 mv-0:1 6v. R1?1_�C,�PIE9 CITY OF 'WK0LA JUN 27 2016 PERMIT CENTER DEMOLITION PLAN DATE DESCRIPTION ........ ................ .................. ............................................. ........ ................ .................. .......................... _, .....0 .. '..YA?'..'.1.. : T: r � � SEATTLE CHOCOLATES 1180 ANDOVER PARK WEST TUKWILA, WA 98065 SEATTLE CHOCOLATES CHOCOLATE FACTORY TOUR 1180 ANDOVER PARK WEST TUKWILA, WA 98065 NURIM GENERAL NOTES 1 ST FLOOR POWER/COMMUNICATIONS PLAN I. CIRCUIT NUMBERS SHOWN REFER TO PANEL C1 UNLESS OTHERWISE NOTED. SCALE: 1/4" = V-0" FLAG NOTES 45 KVA TRANSFORMER RELOCATED FROM UPS ROOM. PROVIDE EQUIPMENT, MATERIALS, AND LABOR REQUIRED TO EXTEND CONDUIT AND CONDUCTOR TO FEED TRANSFORMER AT NEW LOCATION. RE -LABEL PANEL AS C1 (PREVIOUSLY UPS1). PROVIDE EQUIPMENT, MATERIALS, AND LABOR REQUIRED TO EXTEND CONDUIT AND CONDUCTOR TO FEED PANEL AT NEW LOCATION. VERIFY LOCATION OF INSTA-HOT WITH OWNER PRIOR TO ROUGH -IN. Consulting Electrical Engineers 19515 North Creek Parkway, Suite 302 Bothell, Washington 98011 Phone: 425-402-9400 Fax: 425-402-9402 C-16178 POWER AND COMMUNICAITONS PLAN _. DATE DESCRIPTION E IEWED O COMPLIANCEWITH.............................................................................................. PA 7®®NEC .............................................................................................. JUL 19 2016 ............................................................................................ City ofTukWila BUILDING DIVISION .................................................................... �� p� F� C, I e�, CITY CITY Oi" i1 UKOLA JUN 27 2016 PERMIT DENTED x � x i{ ,I i FACILITY ACCESS AJ 1 101 LF5 H-30DMX/R5 2 (TYPICAL 26 PLACES) LF5 H-30DMX/R5 LF5 H-30DMX/R5 LF5 H-30DMX/R5 LF5 H-30DMX/R5 LF5 H-30DMX/R5 LF5 H-30DMX/R5 LF5 H-30DMX/R5 i (( NINE MORE FIXTURES ON THIS I CIRCUIT CONTINUE ±44' ON THIS WALL. 'N FACILITY ACCESS 102 11, 26 �26+ LF8 i r' OS �� I I WAY LF2 0 I C1-1b/R2 0 17 17 17 I 1 0 17 L LF7 -- 4 f LF4 I LF4 1 LF4 ------ --------- .... .. -0 SALES 10 I 26a/R1 +...__.._.. _._� 26a/R1 } 26a/R1----__ I! SPACE > "I I ` I I C � k 26 i 26f/R1 L -F4- -- ---- '- _ __ _.._ _ _._.._LF4 _ _..__._. ____�._ .. �_--{_'-- -_..__ LF4-------- 277V __._... : I 26a/R1 26a/R1 26a/R1 DIM RETAIL -SALES FLOOR 111 i � I i! V V V„ V V p 0 A A I I SWITCHBANK _--o- 26 1 9.03 I Lf7 LF7 L LF7 -- 0 26 26 X1 /O % 1 26 O 26 1 O O 2fi�_ 26 `� SALES I E2 0 I,1�- l LF8 LF8 WOMANS ROOM tEB 1 9LF7 LF7 LF7 O O O I SLV 26 26 26 ` l i I LF7 LF7 f 26 ° os 26 O 1 l C 1-51;1 LF7 1 LF7 LF7 LF7 O +}_} 1 026 I 1 O� li ( �+ O I� B 1 _. �LF3 -�� LF3� — i 26 O � (Cl -5 26- ; MENS ROOM 26 j I ( C1 5 I -'_ 105 LF7 LF7 I; LF7 ! 4 OS } O O p( I 26 26 i1 26111 A26 „0Sj O { { 'LF8 f ' 26 26 �, 261 L LF9 _ C 26526 UTILITY ROOM KITCHENETTE 1 6 i i 107 0 LF9 I LF9 26 f 26 it LF7 O NORTH 1 ST FLOOR LIGHTING PLAN lqlo_A�p SCALE: 1/4" = 1'-0" X1 26 X1 26 UJ C1-3e/R3 I LF2 F —J I LF2 C1-3f/R3 FACTORY ACCESS X1 LF40 0 LF4 LF4 0 28 28h/R4 28h/R4 28h/R4 is NOTES: 1. CONTRACTOR TO VERIFY EXACT CONFIGURATION REQUIRED WITH SPACE AVAILABLE. 2. PROVIDE LABELS AS DIRECTED BY OWNER. 3. SWITCHES SHALL NOT BE MOUNTED HIGHER THAN 48" AFF. 4. INSTALL DMX CONTROLLER PER MANUFACTURERS REQUIREMENTS. FACTORY START UP BY AUTHORIZED DEALER IS REQUIRED. SWITCHBANK DETAIL NO SCALE GENERAL NOTES .T r 1. CIRCUIT NUMBERS SHOWN REFER TO PANEL H1 UNLESS OTHERWISE NOTED. FLAG NOTES PROVIDE SLAVE PACK FOR 120V CIRCUITS. R�> FIXTURE CONTROLLED VIA ACCLAMART 500 TOUCH PANEL CONTROL AND TIMECLOCK. PROVIDE SOFTWARE, FITTINGS AND CABLING PER MANUFACTURER'S REQUIREMENTS. REVIEWEDFUR COMPLIANCE WITH NEPA 70 - NEC JUL 19 2016 ..•. C!t/ ®ffukWlla ILDINCG DIVISION N� CITE' OF •BTU"Mi"iLI,A JUN 27 2016 PERMIT CENTER SEATTLE CHOCOLATES CHOCOLATE FACTORY TOUR 1180 ANDOVER PARK WEST TUKWILA, WA 98065 CASh ENGINEERINC Consulting Electrical Engineers 19515 North Creek Parkway, Suite 302 Bothell, Washington 98011 Phone: 425-402-9400 Fax: 425-402-9402 C-16178 1ST FLOOR LIGHTING PLAN DATE DESCRIPTION Ili RETAIL RETAIL 0 © 0 RETAIL SALES SALES FLEX FLEX FLEX { FLEX SPACE > SEATING I C � �t 26f/R1 120V 120V 277V 0 277V DIM LF4 DIM -__ DIM 26f/R1 ' I 1 C1-1 C1-5 H1-26 C1-3 H1-26 a b c LF4 r f FLEX FLEX SPACE li LCP 109 f 1 j 109 26f/R1 MEZZAINE SWITCH 120V 277V NOTE 120V SLV �] DIM DIM �LF4.I xl •> 26f/R 1 C1-3 H1-28 C1-7 _ h LFA t I II 2 HR C1-3e/R3 I LF2 F —J I LF2 C1-3f/R3 FACTORY ACCESS X1 LF40 0 LF4 LF4 0 28 28h/R4 28h/R4 28h/R4 is NOTES: 1. CONTRACTOR TO VERIFY EXACT CONFIGURATION REQUIRED WITH SPACE AVAILABLE. 2. PROVIDE LABELS AS DIRECTED BY OWNER. 3. SWITCHES SHALL NOT BE MOUNTED HIGHER THAN 48" AFF. 4. INSTALL DMX CONTROLLER PER MANUFACTURERS REQUIREMENTS. FACTORY START UP BY AUTHORIZED DEALER IS REQUIRED. SWITCHBANK DETAIL NO SCALE GENERAL NOTES .T r 1. CIRCUIT NUMBERS SHOWN REFER TO PANEL H1 UNLESS OTHERWISE NOTED. FLAG NOTES PROVIDE SLAVE PACK FOR 120V CIRCUITS. R�> FIXTURE CONTROLLED VIA ACCLAMART 500 TOUCH PANEL CONTROL AND TIMECLOCK. PROVIDE SOFTWARE, FITTINGS AND CABLING PER MANUFACTURER'S REQUIREMENTS. REVIEWEDFUR COMPLIANCE WITH NEPA 70 - NEC JUL 19 2016 ..•. C!t/ ®ffukWlla ILDINCG DIVISION N� CITE' OF •BTU"Mi"iLI,A JUN 27 2016 PERMIT CENTER SEATTLE CHOCOLATES CHOCOLATE FACTORY TOUR 1180 ANDOVER PARK WEST TUKWILA, WA 98065 CASh ENGINEERINC Consulting Electrical Engineers 19515 North Creek Parkway, Suite 302 Bothell, Washington 98011 Phone: 425-402-9400 Fax: 425-402-9402 C-16178 1ST FLOOR LIGHTING PLAN DATE DESCRIPTION Ili RETAIL RETAIL RETAIL SALES SALES FLEX FLEX FLEX I 1 SALES TRACK SEATING 110 110 109 277V 120V 120V 277V 120V 277V DIM DIM DIM DIM DIM DIM ' I H1-26 C1-1 C1-5 H1-26 C1-3 H1-26 a b c d e f FLEX LCP f 1 j 109 HALLWAYS MEZZAINE SWITCH 120V 277V NOTE 120V SLV —.--- - DIM DIM 4 DIM C1-3 H1-28 C1-7 9 h DMX m 2 HR CONTROLLER OVERRIDE C1-3e/R3 I LF2 F —J I LF2 C1-3f/R3 FACTORY ACCESS X1 LF40 0 LF4 LF4 0 28 28h/R4 28h/R4 28h/R4 is NOTES: 1. CONTRACTOR TO VERIFY EXACT CONFIGURATION REQUIRED WITH SPACE AVAILABLE. 2. PROVIDE LABELS AS DIRECTED BY OWNER. 3. SWITCHES SHALL NOT BE MOUNTED HIGHER THAN 48" AFF. 4. INSTALL DMX CONTROLLER PER MANUFACTURERS REQUIREMENTS. FACTORY START UP BY AUTHORIZED DEALER IS REQUIRED. SWITCHBANK DETAIL NO SCALE GENERAL NOTES .T r 1. CIRCUIT NUMBERS SHOWN REFER TO PANEL H1 UNLESS OTHERWISE NOTED. FLAG NOTES PROVIDE SLAVE PACK FOR 120V CIRCUITS. R�> FIXTURE CONTROLLED VIA ACCLAMART 500 TOUCH PANEL CONTROL AND TIMECLOCK. PROVIDE SOFTWARE, FITTINGS AND CABLING PER MANUFACTURER'S REQUIREMENTS. REVIEWEDFUR COMPLIANCE WITH NEPA 70 - NEC JUL 19 2016 ..•. C!t/ ®ffukWlla ILDINCG DIVISION N� CITE' OF •BTU"Mi"iLI,A JUN 27 2016 PERMIT CENTER SEATTLE CHOCOLATES CHOCOLATE FACTORY TOUR 1180 ANDOVER PARK WEST TUKWILA, WA 98065 CASh ENGINEERINC Consulting Electrical Engineers 19515 North Creek Parkway, Suite 302 Bothell, Washington 98011 Phone: 425-402-9400 Fax: 425-402-9402 C-16178 1ST FLOOR LIGHTING PLAN DATE DESCRIPTION Ili MEZZANINE EXPANSION ?.OZ LF4 28h/R4 EXISTING I'VI EZZ_AI N E 20Z EXISTING MEZZAINE 201 1O ■ 'WARITAL LIGHTING -WALKWAY PLAN EXISTING MEZZAINE 201 LF4 () LF4 0 1 28h/R4 28h/R4 --- - - -- B1 28 !{ ii (I --- 1;!X1 r' 28 - j EXISTING (N.I.C.) 81 �28 LF4 28h/R4 LF4 0 28h/R4 B1 LF4 t0 28h/I 28 ---- LF4 0 28h/R4 MEZZANINE EXPANSION zo2 LF4 B1 28h/R4 t 28 LF4 0 LF4 r) 28h/R4 B1 t 28 �- LF2 -C1-7m/F Ll B1 28h/R4 t 28 SEATTLE CHOCOLATES 1180 ANDOVER PARK WEST TUKWIL.A, WA 98065 SEATTLE CHOCOLATES CHOCOLATE FACTORY TOUR 1180 ANDOVER PARK WEST TUKWILA, WA 98065 C AS ENGINEERING Consulting Electrical Engineers 19515 North Creek Parkway, Suite 302 Bothell, Washington 98011 Phone: 425-402-9400 Fax: 425-402-9402 C-16178 «• + t; Ls 33273 ,.a "" -.,K ... TV" REVIEWED I UH , COMPLIANCE WITH F A 70 N.E JUL 19 2016 City ®f 1"ul�viOi BUILDING DIVISION CITY OF TUK0L.A LF4 28h/R4 1;I JUN 27 2016 PERMIT CENTER 81 LF4 28 It 28h/R4 MEZZANINE EXPANSION 202 PARTIAL LTG -WALKWAY PLAN DATE DESCRIPTION .............................................................................................. E2.1 FACILITY ACCESS 101 LF2 - ---' - i j LF4.. LF2 . LF2 5.1.8 1.8 1 8.1.7,1 7 ',1 2.11 2:1 2.3 2.6 2.8 4.0 '6.7 5:5 3.6.2:7 3.4 2.8 2.6 2 6� 2.3 2.2 �2.3 2.2 2.4 2.4 2.6 2.8;3.3 1 2.826.x.0 3.2 2.3 2.0 1.8 1.6 1.6 1.4 1.7 1.6 1.8 2.1 2.0 2.0 1.8 2.0 2. ' ..2 2.3 2.4 2.5 2.6 2.3 2.0 1.5 - - { 5 6 1:6-1.8"'1.6 1.7.1.9' .rl 2 2.1 2:1 ' . . .4 2.3 2:2 �2.7 3 2.3 2.2 2.2 2.4 2.7 3.5 4.1 3.6 2.7 2.0 1.9 1.9 1.7 1.5 1.6 1.7 1.7 1.8 2.0 2.0 2.0 1.9 2.0 2. ' . 2.1 2.1 1.9 2.0 2.1 1.8 1.7 1.6 1.5 X 1 I . I I I 1 0 i -� - �` 4 2.3 ' 2.4 2.2 2.0 2.1f2.4 2.6 2.6 2.4 2.1 1.9 1.7 1.5 1.7 1.7 1.8 1.6 1.9 1.9 2.0 2.2 1.9 2.1 2.1 2.2 2.2 2. 2.1 2.0 1.9 1.8 1.8 1.6 1.7 LF4 1.4 6.17.6 1 9 1' 6 1,8 ` 1 8 ?�.1 2.1 2.0 2.1 2.4 2.3 2:3 2 M.7 2.6 2.5 2 6 2.4 2.4 2. 2,�';j __..._ .__ _ _ __._-..._ f r 1 f f i 1 l .9 *1.7 *1.6 --- -- --- _- - -� �.. _ ___ _ -_� - - - --- - --- _ .._.. _ - --- --"--- --- -- - --*1.7 FLEX109 ACE----_-�_ - - { _. _ - - - -- - LF4- LF4 -LF4- - - - LF41 - -- : - -i l . �_. 241 91 7 j 0 0 I 2.9 *2.2 *1. ,:r` ---1,i E,, I> 3 I; LF1A { t: I � r at I 3.22.32.0 a ''� �,!� f : - I :.LF4. �. ....JS j 4 I RETAIL -SALES FLOOR { 2.8 2.4 2.2 282522 1 2.5 2.4 2.2_!: ' ' • `� I�f a ( :(} t { (, t. " 'ti. f �kf, i`1 1 if� �$ J'~YJ� i ( 9 j 2.5 2.4 2.2 LF1 A j i I na 2.3 2.1 2.0 I ; - { ; I -- -- -- -- - 2.2 2.1 2.1 , I L_ LF4 LF4 LF4 I LF4. - - - - -- I 2.2 2.1 2.1 I 1 17 0 D 01 E j LF5 X 1 X1 . .2 2.2 _.' LF6 LF6 LF6 LF6 LF6 LF6 LFA 2.3 2.1 1.9 {_I LF2 - -1 - - , I 52.52.62.32.91.91.91.7 1.71. 1.7C1F52.42.01.8.�' LF8 I II j1 2.72.73.03.1 2.72.1 2.1 2.11.9 . ' .42.72.83. ' . 3.92.92.2 . .81.61. LF5 2.83.44.1 4.03.42. 2.1 2.02.2 . 33.63. ' . ' . 2.72.3'. FACILITY I� L� 6 ACCESS 1oz j �J HALLWAY LF5 IL 7 LF7 LF7 ' LF7\'`---`_il X 1 O Of O- ! WOMANS ROOM I LF8 LF8X C a , ,LF7 LF7 LF7 ,� LF7,^ j LF5 ii -- 1 LF LF'" �.�; _�_-_ p ILF7 LF7 _ MENS ROOM '! I O C 1 O 110 `� -- -- - -- _ LF /� LF7 �/ LFF 5 O Oli' -„L I - 1{FF__ LF7 LF7 LF O O ! O LF5 __ _ I I ' ,i. - t LF7 L'7 LF7 O O O i : ii LF5 � I U FY ROO LI :1 LF9 F9 ------- I ijf LF5 LF9 ` JLT--LF91 EMERGENCY EGRESS LIGHT LEVEL Illuminance (Fc) Average = 3.77 Maximum = 27.1 Minimum = 1.1 Avg/Min Ratio = 3.43 Max/Min Ratio = 24.64 1 ST FLOOR EMERGENCY LIGHTING SCALE: 1/4" = 1'-0" 1 6 1 8 1.9' .2' .6 .8 3. 4. 4. `T� 611 21911 11-12,5-1 ' .8 .8j3.0�3.5 4.0� 4. 5. 27.11 .3411.3 2 6' .9' .6' .4 .5 7 8 3.59; 3. 4. 5. 18'61713j8+2.�1 �.5�513,213.4 5.123 J3 213 SEATTLE CHOCOLATES 1180 ANDOVER PARK WEST TUKWILA, WA 98065 SEATTLE CHOCOLATES CHOCOLATE FACTORY TOUR 1180 ANDOVER PARK WEST TUKWILA, WA 98065 �arYCASEd ENGINEERING Consulting Electrical Engineers 19515 North Creek Parkway, Suite 302 Bothell, Washington 98011 Phone: 425-402-9400 Fax: 425-402-9402 C-16178 � a p1Rn ISE VIEV&Le iur,. COMPLIANCE WITH NFPA 70 - NEC JUL 19 2016 GiFof•Tukuvila BUILDING DIVISIoi'Q R E C EI11 CITY OF 'T 3..IKVV3l..A JUN 27 2016 PERMIT CENTER EMERGENCY LIGHTING FLOOR PLAN 0 DATE DESCRIPTION I � , PARITAL EMERGENCY LIGHTING -WALKWAY PLAN SCALE: 1/8" = V-0" EMERGENCY EGRESS LIGHT LEVEL Illuminance (Fc) Average = 3.77 Maximum = 27.1 Minimum = 1.1 Avg/Min Ratio = 3.43 Max/Min Ratio = 24.64 NORTH ip �X L REVIEWIzu COMPLIANCE�- NFPA-70 NF -r. JUL 19 2016 City of�TukWili........ BUILDING DIVI 111Na CITY OF TI.,IlamI-NiLA JUN 2'7 2016 PERMIT CENTER SEATTLE CHOCOLATES 1180 ANDOVER PARK WEST TUKWILA, WA 98065 SEATTLE CHOCOLATES CHOCOLATE FACTORY TOUR 1180 ANDOVER PARK WEST TUKWILA, WA 98065 CAS-U-jENGINEERING Consulting Electrical Engineers 19515 North Creek Parkway, Suite 302 Bothell, Washington 98011 Phone: 425-402-9400 Fax: 425-402-9402 C-16178 EMERGENCY LIGHTING FLOOR PLAN Q DATE DESCRIPTION ............................................................................................ hL2.1