Loading...
HomeMy WebLinkAboutPermit EL16-0600 - NGUYEN RESIDENCE - ROOF MODULESNGUYEN RESIDENCE 3850SI26 TH ST CANCELLED 08/02/16 EL16-0600 CITY OF TUKWILA Community Development Department • Permit Center • 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://www.Tukwi]aWA.gov Electrical Permit No. V/ 06 00 Project No. Date Application Accepted: 69 Date Application Expires: use ELECTRICAL PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. "Please Print" SITE LOCATION ::1 King Co Assessor's Tax No.: Site Address: 3850 South 126th Street Suite Number: Floor: Tenant Name: New Tenant: ❑ .....Yes ❑ ..No PROPERTY OWNER Name: TIM Contruction NW, LLC Address. 3850 S 126th St City: Tukwila State: WA Zip: 98168 CONTACT PERSON — person receiving all project communication Addition Name: Jon Lange ❑ Address. 4546 Leary Way NW City: Seattle State: WA Zip: 98107 Phone'. "Pax: 206-571-4726 9 Email: ❑ jonl@sunergysystems.com HAApplicationsTorms-Applications On Line\2014 ELECTRICAL CONTRACTOR INFORMATION Company Name: Sunergy Systems Inc. Address: 4546 Leary Way NW City: Seattle State: WA Zip: 98107 Phone: 206-571-4726 Fax: Contr Reg No.: sunersi905d4 Exp Date: 4/18 Tukwila Business License No.; Valuation of Project (contractor's bid price): $ 31,500.00 (10,450.00 without the modules) Scope of Work (please provide detailed information): Install 33 itek 295watt modules on roof, install 7600watt ac output max interactive inverter (no batteries), with 40a backfeed breaker into 200a Main panel. Also install new service meter/mast and main panel. Will service be altered? [2) Yes ❑ No Type of Use: Tvoe of work: 9 New ❑ Addition ❑ Service Change ❑ Low Voltage ❑ Generator ❑ Fire Alarm Property Served by: 9 Puget Sound Energy ❑ Seattle City Light HAApplicationsTorms-Applications On Line\2014 ApplicationsTlectrical Permit Application Revised 1-1-14.docx Revised: January 2014 bh Adding more than 50 amps? ❑ Remodel ❑ Telecommunication ❑ Yes Q) No ❑ Tenant Improvement ❑ Temporary Service Page 1 of 2 RESIDENTIAL NEW RESIDENTIAL SERVICE ❑ New single family dwellings ...................................$152.85 (including an attached garage) ❑ Garages, pools, spas and outbuildings ........................ $81.90 ea ❑ Low voltage systems (alarm, furnace thermostat) ................................ $59.85 ea RESIDENTIAL REMODEL AND SERVICE CHANGES ❑ Service change or alteration ...................................... $81.90 ❑ (no added/altered circuits) $86.25 Service change with added/altered circuits ................. $81.90 ❑ number of added circuits ........................ $11.55 ea ❑ Circuits added/altered without service change ........... $54.60 (up to 5 circuits) $10.80 ea ❑ Circuits added/altered without service change ........... $54.60 (6 or more circuits) ............................................... $7.65 ea `Meter/mast repair ....................................................... $68.25 ❑ Low voltage systems ................................................. $59.85 (alarm, furnace thermostat) PERMIT APPLICATION NOTES - MULTI -FAMILY AND COMMERCIAL Fees are based on the valuation of the electrical contract. MISCELLANEOUS FEES ❑ Temporary service (residential) ................................. $65.00 ❑ Temporary service (generator) ................................... $80.90 ❑ Manufactured/mobile home service ........................... $86.25 (excluding garage or outbuilding) ❑ Carnivals.................................................................... $80.60 Number of concessions ......................... $10.80 ea Each ride and generator truck ............... $10.80 ea * * *EFFECTIVE JANUARY 1, 2014 EACH PERMIT WILL BE ASSESSED A 5% TECHNOLOGY FEE*** Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The Building Official may grant one extension of time for an additional period not to exceed 90 days. The extension shall be requested in writing and justifiable cause demonstrated. I HEREBY CERTIFY THAT] HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. Mailing City H:\Applications\Forms-Applications On Line\2014 ApplicationsTlectrical Permit Application Revised 1-1-14.do" Revised: January 2014 bh Date: Z 6 �9-i0 7 State Zip Page 2 of 2 Date Paid: Tuesday, June 28, 2016 Paid By: JON LANGE Pay Method: CREDIT CARD 08697G Printed: Tuesday, June 28, 2016 3:16 PM 1 of 1 SYSTEMS Rachelle Ripley From: Jon Lange <jonl@sunergysystems.com> Sent: Tuesday, August 02, 2016 5:31 PM To: Rachelle Ripley Subject: RE: cancel permit for: 3850 South 126th St Hi Rachelle, I never picked up the permit, but was told it was ready to issue. It is the one for the photovoltaic solar system. Sorry, does that help? Jon Lange President/ Electrical Administrator U-1 L', .. I�SYSTEM. S Fy <<� 4546 Leary Way NW, Seattle, WA 98107 WA: GCL# SUNERS1905DU WA: ECL# SUNERS1905D4 Email: JonL@sunergysystems.com W: 206.297.0086 C: 206.571.4726 Web: www.sunercivsystems.com pv Inslaht'jon P'rok-ssional Joe lupe ceet 8= 115"410 How you can keep #SolarStrong, Start here by signing our petitionn to protect our Production. Incentive Program! From: Rachelle Ripley [mailto:Rachelle.Ripley@TukwilaWA.gov] Sent: Tuesday, August 2, 2016 11:30 AM To: Jon Lange <jonl@sunergysystems.com> Subject: RE: cancel permit for: 3850 South 126th St Hi Jon, Do you have a permit number to reference on this? Rachelle Ripley Permit Technician I City of Tukwila 6300 Southcenter B1, Suite ioo I Tukwila, WA 98188 T: 2o6.433.7165 I F: 2o6.431.3665 Rachelle.RipleyrTulcaWA.gov I http://www.TukwilaWA.gov From: Jon Lange[mailto:ionl@sunergvsystems.com] Sent: Thursday, July 28, 2016 12:15 PM To: Rachelle Ripley Subject: cancel permit for: 3850 South 126th St Thanks, Let me know if you need more info. Jon Lange President/ Electrical Administrator OP , A USYSTE S' 4546 Leary Way NW, Seattle, WA 98107 WA: GCL# SUNERS1905DU WA: ECL# SUNERS1905D4 Email: JonL@sunergysystems.com W: 206.297.0086 C: 206.571.4726 Web: www.sunergysystems.com �f FV Installation Pi'otessionay ,torr LMM CAM #R4915M.N How you cart keep ^olarStrong, Start here by signhig our petition to protect our Production Incentive Program! M rl'fl- PERMIT Q 1L) i F. i E D F OR: P'Mechanical [I Elcatrical lumbing C4,6as Piping City of Tukwila BJ2'TJ"�,1N'G' DIVISION REVISIONS o changes -,h,-!l ho rnade to the scope - - ---------- of %'Mrk ofithc,;i prior approval of r3;);'ding Division ivi'l require a new plan submittal (-,rd may intr,-1L!da additional plan review fees. HEVIEWED FOH W - COMPLIANCE IT- H FILE COPY NFPA 70 - NEC Permit No. F=�W(g-C-600 JUL 19 2016 121--i approvai is subject to errors and omissions. J llaLu construction documents does not authorize City of Tukwila. .0 vlo!atiori cy" any adopted code or ordinance. Receipt BUILDING DIVISION of approved Field Copy and conditions is acknowledged: By: Date: City of Tukwila BUILDING DIVISION PVI 800TL PVI 5200TL P 16600TL PVI 7600TL FEATURES • 00 DC • ig t o us r a d • fficienaies • Ig tw fight, co a e n s a es n he in ust y • Q io n eas m to l ion • Wi e o ra fi g t g a ge • C dis o n • a iv ooling • DC rc- a I e ec• ion n in p OPTIONS • b -b sed o i o g • eve a gra a onit nng REVIEWED FOR COMPLIANCE WITH NFPA 70 - NEC JUL 19 2016 City of Tukwila BUILDING DIVISINU #-SOLECTRIA A YASKAWA COMPANY ;SII. i nr. f E IED JUN 28 2016 PERMIT CENTER TRANSFORMERLESS STRING INVERTERS Solectria Renewables' PVI 3800TL, 5200TL, 6600TL, and 760OTL are compact, transformerless, single-phase inverters with the highest peak and CEC efficiencies in the industry. These inverters come standard with an integrated DC disconnect, DC arc -fault detection and.interrupt, 1 or 2 MPP tracker(s), and a user -interactive LCD and keypad. Their small and lightweight design make for quick and easy installation and maintenance. They have an innovative passive cooling design which eliminates the need for fans in the inverter. These inverters include an enhanced DSP control, comprehensive protection functions, and advanced thermal design enabling highest reliability and uptime. Ll�%- 0&00•C�-��CIPft LIWA byft9�yw vmuc SPECIFICATIONS r i• 0 1 0 K V O Absolute Maximum Open Circuit Voltage 600 VDC Operating Voltage Range 120.550 VDC d MPPT Input Voltage Range I j 200.500 VDC MPP Trackers 1 2 0 Maximum Operating Input Current 20A 15 A per MPP tracker 18 A per MPP tracker 20 A per MPP tracker o Start Voltage 150 V o z Nominal Output Voltage 208 or 240 VAC, 1 -Ph AC Voltage Range I -12%/+10% 208 VAC r 3300 W 5200 W 6600 W 6600 W Continuous Output Power 240 VAC 3800 W 5200 W 6600 W 7600 W y 208 VAC t 15.8A 25A 31.7A 31.7A a Continuous Output Current - ' 240 VAC 15.8A 21.6A 27.5A 31.7A E Maximum Backfeed Current ' 0 A Nominal Output Frequency 60 Hz a � v Output Frequency Range 59.3.60.5 Hz j J Power Factor Unity, > 0.99 a Total Harmonic Distortion (THD) @ Rated Load i 0% d Peak Efficiency ; 98.3% CEC Efficiency C 97.5% 0 Tare Loss Temperature ! Q W L m Ambient Temperature Range (full power) -130Fto+122°F (-25°C to+50°C) 6 Storage Temperature Range -40°F to +185°F (•40°C to +850C) Relative Humidity (non -condensing) 0.100%o Operating Altitude Data Monitoring 6562 ft/2000 m Optional SolrenView Web -based Monitoring External a - + 0ptional Revenue Grade Monitoring External External Communication Interface RS -485 Testing & Certifications Safety Listings & Certifications UL 1741/IEEE 1547, UL 169913, CSA C22.2#107.1, FCC part 15 A&B J Testing Agency ETL CSA Standard } . 10 year J Optional I — dBA (Decibel) Rating c45 dBA @ 3 m OC Disconnect Standard, fully -integrated Dimensions (H x W x D) 17.5x15.8x8.5in. 26.8x15.8x8.5in. i (445 x 401 x 216 mm) 1 (680 x 401 x 216 mm) Weight 43 lbs (19.5 kg) 65 lbs (29.5 kg) Enclosure Rating Type 4+Salt Mist Corrosion Protection Enclosure Finish Aluminum , SOLECTRIA AYASKAWACOMPANY www.solectria.com I inverters@solectria.com 1 978.683.9700 ifek ENERGY SE SOLAR MODULES Design & Engineering Data Cell type • 60 high -efficiency monocrystolline p -type cells 285 • 6x10 cell matrix Solar Glass • Ultra -clear anti -reflective treatment Maximum Power Voitage - Vwr(V) • Tempered, with low iron content 32.4 • Anti -glare prismatic subsurface texture Backsheet Multi -layered Maximum Power Current . I- (A) • Engineered adhesion for maximum weather protection Frame High-strength corrosion -resistant anodized aluminum 8.9 • Compatible with standard racking, accomodating both top-down Open Circuit Voltage - V« (V) clamps and bottom -flange mounting Cable • 42" 90C 12 AWG PV wire • 1000 VDC MC4 connectors Junction Box • 3 bypass diodes • 1000 VDC Grounding • Certified for Wiley Electronics WEEBTm grounding clips 9.4 • Eight standard grounding locations per module for 9.6 reduced ground wire length UL Listing UL 1703 /�,"'� Fire Rating Type 2 us Certified Made lntertek In -s -9 - NOTE: SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE Maximum Power - P-(Wp) 280 285 290 295 300 Maximum Power Voitage - Vwr(V) 32.3 32.4 32.6 32.8 32.9 Maximum Power Current . I- (A) 8.6 8.7 8.8 8.9 9.0 Open Circuit Voltage - V« (V) 39.2 39.3 395 39.7 39.8 Short Circuit Current - lu(A) 9.3 9.4 9.5 9.6 9.7 Module Efficiency 16.70% 16.99% 17.29% 17.59% 17.89% 101.5 mm [4 in] 79.5 mm [3.13 in]_ 100 mm [3.94 in] 27 mm [1.061n] 178 mm [7 in] REVIEWBU► -L0 COMPLIANCE W NPPA 70 - NEC JUL 19 2016 City of TUIWla BUILDING DIVISION 203 mm (8 in] 1067mm [42 in] Junction Box 9.5 mm 0 (.375 in) TYP SIL =-so O itekenergy The Best Choice For Solar itekenergy.com i WA. 360.647.9531 MN. 612.318.6369 Dimensions 1001 mm X 1675mm X 50mm Weight 43 lbs T Operational Temperature -40...+ 90°C Maximum System Voltage 1000 VDC Design Load (UL 1703) up to 113 lbs/ft' Maximum Load (UL 1703) 551 kg/m2 (5400 Pa) Maximum Wind Load 113lbs/ft2 Max Series Fuse Rating 15A Max Reverse Current 15A Nominal Operating Cell Temperature (NOCT) 46.69°C Temperature Coefficient of P- -0.40%/°C Temperature Coefficient of Vm -0.207./°C Temperature Coefficient of I - +0.04%/°C Temperature Coefficient of Vwr - 0.45 %/°C 'Electrical characteristics may vary within ±2% of the indicated values at Standard Test Conditions (STC): Irradiance of 1,000W/m', AM 1.5 spectrum, cell temperature at 25° 5 m 0 [.198 in] TYP Frame Depth: 50 mm [1.9685 in] 1219 mm [48 in] 1675 mm [65.94 in] L_ l �-- 0400 1001 mm 139.41 in] 947 mm [37.28 in) RECEIVED 610 mm [24 in] CITY OF TUK ILA JUN 2 8 2016 PERMIT CENTER V06.3.16 a' 33 MODULE PV ARRAY-9,74kW STC ITEK 295SE-B (2 Strings of 10, 1 of 13) PV Modules Series String characteristics 295W/32.8V/8.9A Voc=438/569V, Vmpp=328/426V, Voc=39.7v, Imp=8.9A, Isc=3x(9.9xl.25) = 36A Isc=9.6A r— • — — • — Al PV �( Module 1 MODULE EQUIPMENT GROUND – UL listed/NEC compliant, Unirac Ground system PV Module 2 �1 �fj V VOC calculation: NOTES: Module temp. 1. ALL SERIES CONNECTED PV MODULES SHALL BE INTERCONNECTED WITH MANUFACTURER SUPPLIED coefficient:.123V / C MC -4 GENERATION 2, LOCKING CONNECTORS. Record Low: -8C 2. PV SOURCE CIRCUIT JUNCTION BOX SHALL BE LOCATED ON THE ROOF AND NEMA 3R RATED. DeltaT: 33C 3. ALL WIRES FROM ROOF JUNCTION BOX TO INVERTER SHALL BE 10AWG.THHN AND IN CONDUIT TO MEET 33' .123 = 4.06v NEC CODE AND LIMIT VOLTAGE DROP TO LESS THAN 2%. 39.7 + 4.06v = 43.76 4. WIRING IN DC CIRCUITS TO BE RATED 600V -90C, EXPOSED CABLES SUNLIGHT RESISTANT. 43.76' 10 = 438VOC 5. PV SYSTEM Voc SHALL NEVER EXCEED 600 VDC (using historic lowest temperature for safety factor) 43.76 " 13 = 569VOC 6. INVERTERS INTEGRAL LOCKABLE DC DISCONNECT SHALL BE USED AS THE PV SYSTEM DC DISCONNECT. 7. INVERTER SHALL BE LOCATED NEAR THE BILLING METER, SYSTEM COMPONENTS CLEARLY LABELED. I I 8. PRODUCTION METER SHALL BE LOCATED NEAR THE BILLING METER. 9. WIRING FROM INVERTER TO SOLAR METER AND PANEL SHALL BE THWN IN CONDUIT. 10. PV MODULE CONTINUOUS GROUNDING CONDUCTOR SHALL BE UNIRAC UUETL LISTED SOLAR MOUNT GROUNDING TO RACKING SYSTEM. 11. PV RACKING GROUNDING ELECTRODE CONDUCTOR SHALL BE #6 CONTINUOUS COPPER. I I MARKING/LABELING SOLAR kWh 200 AMP SERVICE Meter #' METER �i! I I Ungrounded, DC conductors Red- PER NEC 690 PV Wire -4 R #8AWG CU OR 1 2 ' GREATER GFDI PROTECTION / MPP n MIW 7.6kW INVERTER Solectria I Independent MPP I AC OUTPUT _ 9 I I FluNE 2 I 240 VAC 1 ••.•• - i 60HZ, 31 7AAC(max) 120/240 VAC 14 Meter L L N 1 12 I I i 1..► UNE 1 —IriPv i i600wmp' _ 200amp PIN r T o Service REVIEWED. Neutral I i I and Pa nYe CON GND by NPA70-N"0 rg e 13 une DC IA6 DISCONNECT JUL 1 9 201 I I I SWITCH '-------- 40,d- I MP 10AWG- ` — — — — — — — — 60 amp utility — — — — �--___- HVVPI-2 AC disconnect 10 City of TuI(W • I Black- (locking, visible break)GND - _.... _.......... ,. . .. i PV Wire I I r-�EIVED CONTINUOUS Grounding Electrode Conductor – #6 awg, bare Copper JUN 2 8 2016 PERMIT CENTER nel with 200a utility District: Utility: PSE CONFIDENTIAL, PROPERTY OF Sunergy Systems Suner Systems 9y y AHJ: Tukwila 4546 Leary Way NW Seattle, WA 98107 TIM Construction NW LLC Revised: 628/16 Project: Jon Lange, NABCEP 9.74 kW Itek/Solectria-itek Photovoltaics stem Drawn By: Site Address: 3850 South 126'h St Tukwila, WA 98168 Titre/PaNDescrition: PV ELECTRICAL CONFIGURATION DRAWING Howard Lamb, MSEE Electrical Engineer Approval: Howard Lamb, MSEE Date: 02/23/2016 Span Chart Notes it Galauiatfon6 the iollowing support conditions: A) IWO sftWOWrails snitwwoheovy MIS are used to support modtfits porpendkaftr to the loft *do of the nm k". 8) T1h*staredrv11supports the rnmkilss poralld totheloft wire of the nvdwm. P 6&wkiksone assumed asomen' IV 66' x 40' vAth appoxb- ate VMW of Me ID) TkEwtury Width s 2.75' for standard and heavy rats, wW 339' for Awod am. Iq-winzjo#d co InaRk sareused: A) 04 W (cceods In shaded am on Mftl 8)040.755+0.75W(ambobinampshadtdama) Q 0 4 S (controls in shaded was on, ft" gepeSgo!!"ertka shown on Sumo do drawings A20144 A20145andA20149 AP-4OW-0-h-O'shown Is; setwoon Support pokvtL SMwk span osswned for le"ems aver 4160 and! condmxKn Span cormOdw used for lengths 4%' and uvwW. AN langh past last support- " be up to 113 the Wm shown Irs the WAS, [5-- Mhtandqw Igo ds: To be determinedbasodmalta specifte and local code crkwW -41 SUNM4600 Propetles up" starxUal P&M A20144 H40WROM A201A6 Materiel WA Aluminum 8005-75 Aluminum GOO5-T5 fbifth WA Clearand Black Clearand slack Approx VieWt (per Inear (t) plf .85U :1-143 Total Cress Section Aires 110 .723 .973 SoctionModulus (X, -Oda) W .387 .683 Section Wkmk*n (Y-4Ws) W .1W .333 Mornav* of bleviso (X -Alb) W .486 3.049 M onw* of bn#ft (Y—Axil) W .095 .209 Radius of Gyration (*-Ask) In .8" MW ftaus of O"Mon (!r—ads) 1, .33 .6= Hello Standard Rail A20144 0 1 0 � NO DETAIL A DETAIL B DETAIL C DETAIL D s0 0 i 10 20 30 40 SO 60 70 so 10 B-9- 8' Cr T 9- i 6-9- V 0- T 3" S' Cr 4-6- 4'3- a. (Y. 71W r 01 .6. 6.0" W T a., W 51Or 6' 430 zo 2S 7- 1W' 7.3- 7'3' 6.9" L W 61,4'9' 5• 9 S. 3" 51 W 4. OV 4-6- 4'3' 4'3' _30 3S 6. a- 6, sr G. 6'3 1, 5.91. 5 r", 513. 1 4'3" 0 —FiF 'W' 40 61 or —iriF, --g—, 6"F- * I V 3" 5'0' 4" 94' 4' 6' W 3" 4 ii— 9�'F— S—"6—" SO" T 4' 9' 46 1. d3 j 4'0' I 4'0"' soS' 3" 5'3" T 3" 5O 49 46 43 40 s, cr —Fir vo-4� WO 41 :1:1': 4 01' —Go 4W, sp 4' W 4'3' 4' 0' 0- 4' 4 '0-" P W. 4.'OP Wj—"-d4—Pf-r—'FW n _�W a" 4'3" WW VF 4;& - 1- 4'0" 1 0 1 0 � NO DETAIL A DETAIL B DETAIL C DETAIL D s0 Il/l/2016 City of Tukwila Department of Community Development JON LANGE 4546 LEARY WAY NW SEATTLE, WA 98107 RE: Permit Application No. ELI 6-0600 NGUYEN RESIDENCE 3850 S 126 ST Dear JON LANGE, Allan Ekberg, Mayor Jack Pace, Director In reviewing our current application files, it appears that your permit applied for on 6/28/2016, has not been issued by the City of Tukwila Permit Center. Per the International Building Code, International Mechanical Code, Uniform Plumbing Code and/or National Electrical Code every permit application not issued within 180 days from the date of application shall expire and become null and void. Currently your application has a status of APPROVED and is due to expire on 12/28/2016. If you still plan to pursue -your project, you are hereby advised to do one of the following: 1) If the plan review is complete for the project and your application is approved, you may pick up the application before the date of expiration. At the time of permit issuance the expiration date will automatically be extended 180 days. -or- 2) If the plan review is not completed submit a written request for application extension (7) seven days in advance of the expiration date. Address your extension request to the Building Official and state your reason(s) for the need to extend your application. The Building Code does allow the Building Official to approve one extension of up to 90 days. If it is determined that your extension request is granted, you will be notified by mail. In the event that we do not receive your written request for extension or request is denied, your permit application will expire and your project will require a new permit application, plans and specifications, and associated fees. Thank you for your cooperation in this matter. Sincerely, ;a 1 iii Bill Rambo Permit Technician File No: ELI 6-0600 6300 Southcenter Boulevard Suite #100 0 Tukwila Washington 98188 0 Phone 206-431-3670 0 Fax 206-431-3665 PERMIT COORD COPS PLAN REVIEW/ROUTING SLIP PERMIT NUMBER: EL16-0600 DATE: 06/28/16 PROJECT NAME: NGUYEN RESIDENCE SITE ADDRESS: 3850 S 126 ST X Original Plan Submittal Response to Correction Letter # Revision # before Permit Issued Revision # after Permit Issued DEPARTMENTS: 3't� mac, 1-4 � Building Division Fire Prevention ❑ Planning Division ❑ Public Works ❑ Structural ❑ Permit Coordinator PRELIMINARY REVIEW: DATE: 06/30/16 Not Applicable ❑ Structural Review Required ❑ (no approval/review required) REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: DUE DATE: 07/28/16 Approved 0 Corrections Required ❑ (corrections entered in Reviews) Notation: Approved with Conditions Denied ❑ (ie: Zoning Issues) REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: 12/18/2013 F Sunergy Systems Inc. Home t5spa iol CoiitiiCt Safety & Health Claims & Insurance inWashington State Department of Labor & industries Sunergy Systems Inc. Owner or tradesperson 4546 Leary Way NW SEATTLE, WA 98107 Principals 206-297-0086 David Kissinger, PRESIDENT KING County Howard Lamb, VICE PRESIDENT Doing business as Sunergy Systems Inc. WA UBI No. Business type 602 923 081 Corporation License Page 1 of 2 A-%Inilcs tielh INpL&I Workplace Rights Trades & Licensing Verify the contractor's active registration / license / certification (depending on trade) and any past violations. Electrical Contractor Active. ................................................. Meets current requirements. License specialties GENERAL License no. SUNERSI905134 Effective — expiration 04108/2010— 04/09/2018 Designated administrator Lange, Jon Damon License type Electrical Administrator Bond . Lexon Insurance Company Bond account no. 9801597 Received by L&I 04/08/2010 Savings .............. No savings accounts during the previous 6 year period. License Violations ........................................... No license violations during the previous 6 year period. Active. Meets current requirements. License no. LANGEJD860DQ $4,000.00 Effective date 03123/2010 Expiration date Until Canceled I Workers' comp I Do you know if the business has employees? If so, verify the business is up-to-date on workers' comp premiums. L&I Account ID Call L&1 account representative for 192,168-00 account status. ......................... Doing business as SUNERGY SYSTEMS INC https:Hsecure.Ini.wa.gov/verify/Detail.aspx?UBI=602923081&LIC=SUNERS1905D4&SAW= 7/22/2016