HomeMy WebLinkAboutPermit EL16-0800 - 85C BAKERY - TENANT IMPROVEMENT85C BAKERY
1341 SOUTHCENTER MALL
ELl 6=0800
City of Tukwila
• Department of Community Development
• 6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206-431-3670
Inspection Request Line: 206-438-9350
Web site: http://www.TukwilaWA.gov
ELECTRICAL PERMIT
Parcel No:
9202470090
Permit Number: EL16-0800
Address:SOUTHCENTER
MALL
Issue Date: 10/24/2016
WA Cities Electrical Code:
11-3<9
104
Permit Expires On: 4/22/2017
Project Name:
85C BAKERY
2014
Owner:
2015
WA State Energy Code:
Name:
WESTFIELD PROPERTY TAX DEPT
2015
Address:
PO BOX 130940, CARLSBAD, WA,
92013
Contact Person:
Name:
JACK LAN UM
Phone: (425) 315-8840
Address:
12201 CYRUS WAY #500, MUKILTEO,
WA, 98270
Contractor:
Name:
MERIT ELECTRIC INC
Phone: (425) 315-8840
Address:
12201 CYRUS WAY SUITE 105,
MUKILTEO, WA, 98275
License No:
MERITE1044BQ
Expiration Date: 1/20/2018
Lender:
Name:
Address:
DESCRIPTION OF WORK:
TI FOR NEW BAKERY. NEW LIGHTS, NEW KITCHEN POWER,
AND NEW HVAC POWER ON NORTH SIDE ROOF
Valuation of single family: $0.00
Fees Collected: $1,641.84
Valuation of mf/comm: $71,050.00
Type of Work:
TENANT IMP
Electrical Service Provided by: PUGEST SOUND ENERGY
Water District: TUKWILA
Sewer District: TUKWILA
Current Codes adopted by the City of Tukwila:
International Building Code Edition:
2015
National Electrical Code:
2014
International Residential Code Edition:
2015
WA Cities Electrical Code:
2014
International Mechanical Code Edition:
2015
WAC 296-46B:
2014
Uniform Plumbing Code Edition:
2015
WA State Energy Code:
2015
International Fuel Gas Code:
2015
Permit Center Authorized Signature:1&116 AN/1
_ Date: /
I hearby certify that I have read and examined this permit and know the same to be true and correct. All
provisions of law and ordinances governing this work will be complied with, whether specified herein or not.
The granting of this permit does not presume to give authority to violate or cancel the provisions of any other
state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this
development pfimfignd agree to the conditions attached to this permit.
Signature:
Print Nem
Date: /
This permit shall become null and void if the work is not commenced within 180 days for the date of issuance, or if
the work is suspended or abandoned for a period of 180 days from the last inspection.
PERMIT CONDITIONS:
<NONE>
PERMIT INSPECTIONS REQUIRED
Permit Inspection Line: (206) 438-9350
2100
ELECTRICAL FINAL
7003
ROUGH -IN ELECTRICAL
7002
SERVICE
7001
UNDERGROUND/SLAB
CITY OF TUKWILA
Community Development Department
Permit Center
• 6300 Southcenter Blvd., Suite 100
Tukwila, WA 98188
httl2://www.TukwilaWA.gov
Electrical Permit No. fivi V- 0�00
Project No.
Date Application Accepted:
Date Application Expires: _
ELECTRICAL PERMIT APPLICATION
Applications and plans must be complete in order to be accepted for plan review.
Applications will not be accepted through the mail or by fax.
"Please Print"
SITE LOCATION I
l! King Co Assessor's Tax No.:
Site Address: I Southcenter Mall Suite Number:_ Floor: first
Tenant Name: S-5-9egrees' Bakery and Cafe New Tenant: ® .....Yes ❑ .. No
90
PROPERTY OWNER
Name: Southcenter. Mall
Address: 2800 Southcenter Mall
City: Tukwilla State: WA Zip: 98118
CONTACT PERSON — person receiving all project
communication
Name: Jack Lanum
Address: 12201 Cyrus Way #500
City: Mukilteo State: WA Zip: 98270
Phone: (425) 315-8840 Fax: (425) 315-8845
Email: jack@meritei.com
ELECTRICAL CONTRACTOR INFORMATION
Company Name: Merit Electric INC
Address: 12201 Cyrus WA #500
City: Mukilteo State: WA Zip: 98270
Phone: (425) 315-8840 Fax: (425) 315-8845
Contr Reg No.: MERITEI044BQ Exp Date: 01/20/2017
Tukwila Business License No.; BUS0993354
Valuation of Project (contractor's bid price): $ 71,050
Scope of work (please provide detailed information): TI for new Bakery. new lights, new kitchen power, and new
HVAC power on north side roof.
Will service be altered? ❑ Yes [2] No
Type of Use: Restaurant
Type of work:
❑ New ❑ Addition ❑ Service Change
❑ Low Voltage ❑ Generator ❑ Fire Alarm
Property Served by:
2 Puget Sound Energy ❑ Seattle City Light
HAApplicationsWorms-Applications On Line\2014 ApplicationsElectrical Permit Application Revised 1-1-14.doex
Rcvised: January 2014
bh
Adding more than 50 amps?
❑ Remodel
❑ Telecommunication
❑ Yes ❑ No
® Tenant Improvement
❑ Temporary Service
Page 1 of 2
RESIDENTIAL
NEW RESIDENTIAL SERVICE
❑ New single family dwellings ................................... $152.85
(including an attached garage)
❑ Garages, pools, spas and outbuildings ........................ $81.90 ea
❑ Low voltage systems
(alarm, furnace thermostat) ................................ $59.85 ea
RESIDENTIAL REMODEL AND SERVICE CHANGES
❑ Service change or alteration ...................................... $81.90
(no added/altered circuits)
❑ Service change with added/altered circuits ................. $81.90
number of added circuits ....................... $11.55 ea
❑ Circuits added/altered without service change ........... $54.60
(up to 5 circuits)
❑ Circuits added/altered without service change ........... $54.60
(6 or more circuits) ............................................... $7.65 ea
❑ Meter/mast repair ....................................................... $68.25
❑ Low voltage systems ................................................. $59.85
(alarm, furnace thermostat)
PERMIT APPLICATION NOTES -
MULTI -FAMILY AND COMMERCIAL
Fees are based on the valuation of the electrical contract.
MISCELLANEOUS FEES
❑
Temporary service (residential) .................................
$65.00
❑
Temporary service (generator) ...................................
$80.90
❑
Manufactured/mobile home service ...........................
$86.25
(excluding garage or outbuilding)
❑
Carnivals....................................................................$80.60
Number of concessions .........................
$10.80 ea
Each ride and generator truck ...............
$10.80 ea
***EFFECTIVE JANUARY 1., 2014 EACH:
PERMIT WILL BE ASSESSED A 5%
TECHNOLOGY FEET*'
Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject
to possible revision by the Permit Center to comply with current fee schedules.
Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation.
The Building Official may grant one extension of time for an additional period not to exceed 90 days. The extension shall be requested in writing
and justifiable cause demonstrated.
I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER
PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT.
Signa;ame:
re:
Date: 09/01/2016
Print Jack Lanum Day Telephone: (425) 315-8840
Mailing Address: 12201 Cyrus Way #500 Mukilteo WA 98270
City State Zip
H:\Applications\Farms-Applications On Line\2014 Applications\Electrical Permit Application Revised 1-1-14.docx
Revised: January 2014
bh
Page 2 of 2
DESCRIPTIONS
ACCOUNT
1
PermitTRAK
$1,641.84
EL16-0800 Address: 1368 SOUTHCENTER MALL 100 Apn: 9202470090
$1,641.84
ELECTRICAL
$1,578.69
PLAN CHECK FEE
R000.345.832.00.00 0.00
$315.74
PERMIT FEE MULTI-FAM/COMM
R000.322.101.00.00 0.00
$1,262.95
TECHNOLOGY FEE
$63.15
TECHNOLOGY FEE
TOTAL FEES PAID BY RECEIPT: ..
R000.322.900.04.00 0.00
$63.15
$1,641.84
Date Paid: Thursday, September 01, 2016
Paid By: JACK LANUM
Pay Method: CREDIT CARD 05743G
Printed: Thursday, September 01, 2016 11:19 AM 1 of 1 0rE
SY57EM5
INSPECTION RECORD
Retain a copy with permit
INSPE ION N0. PERMIT N0.
CITY OF TUKWILA BUILDING DIVISION
6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-367
Permit Inspection Request Line (206) 438-9350
Project: �
Type of Inspection: f
Address: � � �
Date Called:
Special Instructions:
Date Wanted: aa.
;-/ 13 p rn.�
Requester: 4"
Phone No:
ho134,
} Approved per applicable codes. Corrections required prior to approval.
El
COMMENTS:
Inspector:` / „r Dater 0V t7
REINSPECTION►FEE REQUIRED. Prior to next inspection, feelmust be
paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection.
INSPECTION RECORD
INSPECTION N0.
Retain a copy with permit PERMIT NO.
�
CITY OF TUKWILA BUILDING DIVISION
6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670
Permit Inspection Request Line (206) 438-9350
Project: j�,
Type of Inspection:
Address:
Date Called:
Special Instructions:
Date Wanted: / a.m
Lo/ p.m.
Requester:
Phone No: ` (1 5" hd
FlApproved per applicable codes. LJ Corrections required prior to approval.
" paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection.
INSPECTION RECORD au�
Retain a copy with permit
INSP CTION NO. PERMIT NO.
CITY OF TUKWILA BUILDING DIVISION
6300 Southcenter Blvd- #100, Tukwila. WA 98188 (206) 431-3670
Permit Inspection Request Line (206) 438-9350
Project: ��
&' fy
Type of Inspectio
VIV-144
Address: .17�
Date Called:
Special Instructions:
Date Wanted: y a.
/ p.m.
Requester:
Phone No:
U paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection.
INSPECTION RECORD qq
Retain a copy with permit
INSPECTION NO. PERMIT NO.
CITY OF TUKWILA BUILDING DIVISION
6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670
Permit Inspection Request Line (206) 438-9350
Approved per applicable codes. LJ Corrections required prior to approval.
VVIAIA 6N M, NAAMOM
tX-
REINSPECTION FEE REQUIRED. Prior to next inspection. Pee /rust be
paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection.
INSPECTION RECORD
Retain a copy with permit
INSPECTION NO. PERMIT NO.
CITY OF TUKWILA BUILDING DIVISION
6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670
Permit Inspection Request Line (206) 438-9350
nApproved per applicable codes. LJ Corrections required prior to approval.
M ENTS:
PC
nspector:
❑ REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be
paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection.
INSPECTION RECORD v
Retain a copy with permit 'Ogoo
INSPECTION N0. iiMIT NO.
CITY OF TUKWILA BUILDING DIVISION
6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670
Permit Inspection Request Line (206) 438-9350
Project:
ga
Al
=
Type of Inspection
/
Address:
3 o
Date Called:
Special Instructions:
Date Wanted:&ID
a.
P.M.
r
Requester: 680ij
Phone No: O
Approved per applicable codes. E Corrections required prior to approval.
Ilnspecto, /1h APK1,18 - Iuate:
REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be
paid at 6300 Southcenter Blvd.. Suite 100. Catt to schedule reinspection.
CWO
v
CWJ)
W
W�
"CO
v
Ui
W
CO
J
CP
W
CO
�1
CP
W
(D
D
r
r
o
X
° C) co >
D
CD
w
n
c
c
N
c
°
O U
o X333
�'
7
0
O O N N N
CD
N
�.
CD CD CD CD
C o n o n
Cp O o o o
x 7 7 7 7
7 7 7 7
3 CD M0 CD
n 0 C7 0-
0 CD CD CD CD
CD CZ CZ CZ C2
O O o O
� fl1 N N N
CD Q tZ a Q
N V W N
o
w
w
v,
cn
cn
N
cn
cn
<
(�J
�> O W U) CO 00
:�omrnrnco
V
V
O
O
O
O
O
O
N
3 < < < <
m
�
N
N
N
o
N
O
N
N
N
N
N
0
o ��, o �o o M
\
O
n
n
n
U
v
n
cr
W
n
�,
v
v
v
�,
$
A O O \ O O O O
�
a
m
Lo p O co - O O o 0 3
IMME'l
o_
o
o_
W
fJ O) O V (T O O O O n
(J) w 0 0 0 0 0 0 0 C.
w
W
W
_
`'
O
,•` I
M
m
m
m
Z
M 7 o r
N
N
N
N
N
N
N
O
O
O
•
(7 (� m T. G7 r
M -o -o
00
zz�� ccow--io�x=
Z Z D D
O
j
M
n 0 0 M Z� m m Z
M n G7
v
v
m m O p° o �(�
00
G
D C, p m r- � CNi�
CP
a
M
U) M � -0
c
M
V<
v
Q
N° D
r O
-1
'm
CD
T
C/)Mx
t4 D
i�
rr
D
1
d
=
1.. u
Iro
?
N
?
O
W
Cb
W
OJ
W
A
W
N
co
O
N
M
N
O
A
N
N
N
O
CD
O
�
N
O
co
O
A
N
CO
v
CT
W
-0
(O
�l
CJ)
W
CO
--4
v
Cr
W
(O
�I
Cn
W
W
�
_v
7
o
_7
N
f0
Vv
pp
v
0
7
N
-a
0
C
(n
o
O
l�
No
O
sn
p
CD
N
v
N
n
o
3
(n
O
CD
N
CD
_.
`OG
v
`G
T
-
XW
0
m
n
N
U
CD
N
a
7'
J
>
O
w
N
Q
O C7 W D
;
v
m
o
o
D
m
DO'
p
m
3
o
m
p
CO
m
-n
m
m
v
p
>
r
r
m
v
C11
O
p
c
O
OZ
v
7
C
d
O
=
O0
7
7
d
N
0 � � _6
O —1 3?�
G)�'
-0
O
�
N
�
7
'O
CD
O
7
(D.
N
O
Dl
'�
p
?
t0
�
3
o
�•
j (Un (Un ((n
o
m
a
v
a
v
n
p
�
N
K
m
CD
�
r
s
Z
�
(n
CO
3
O
7
p
o
0
Sco
7
n o o o 0
'CD
N
O
N.m
N
7
CD
Q 7 7 7 7
O
(D
p
N
7 7 7 7
(D CD CD CD
<
CD
0
CD
r
3 0 n 0 n
(D QQQQ
tD
CD Q Q Q Q
,A --
O
ao
OD
o
0
0
(n
0o
(O
N
N
A
N
W
A
6
O
V
o
0
0
0)
0
(n
0
OD
W
A
OD
A
<
N
rn
co N cn A
0)
V
V
A
(D
O
W
d)
A
W
O
A
O
N
W
W
A
a1
N
to (o .A — U)
n
N T. T. T. T�
v N w N N
m
m
m
x
x
;o
;uT
T
A
T.
T
T
T
A
r
r
r
r
n
N
`°
rn
N
N
W
N
O
N
O
N
N
O
N
N
O
N
N
O
N
N
O
N
O
N
O
N
O
N
O
N
O
N
O
N
O
N
O
N
O
N
N
O
N
N
O
N
O
N
O
O
O
N
rn
j N
01)
O�
C)
O
O
0)
n
Q
N
O
O'
Dl
C
Q
N
n
N
n
O'
Dl$Dp
CO IME 00 (.n -4 O \N O) W
�T
W
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
W
\ n
N A (b N (D O O O Cn N
O\
W
O
W
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
/�
Cb CA A w w V O O O V a
W
N
N
W
W
W
W
W
W
W
Cl)
Cl)
N
N
N
N
A�
O A W Ul CO -! O O (n (D
r '
CD
p
Z
m T
N
0
A
0
A
A
O
A
o
A
O
A
O
A
o
A
O
a
O
A
o
A
o
A
O
O
O
O
O
i11
r1
N
N
co
OD
(00
co
•
vvvv m�-�vc�c�r
-o
�
N
m
O
O
Z D D � S 0 O n m m -j
o
O O O O M Z V' 0� m m
a
o
0 Z
00G
m m D m
n
w
v v-0 �c0Unn�
7<
3
O r- c) -u p A n r r (n
f
0
n
n
co
U) D m �1 � m CCnn jl
r Z (1) O O
O
<
o
(D
Dpi
n
0
N DfD
�G
�
(D
N
O
O
�_
O
Q
�(9) \ r 0
i
CD
N
N
O
n
p
CD
N
v
m TI
n
N
O
EL
�]
CDC7(n
CD
O
N
W
(D
(n mA (x�n
°7'
°o
3
CD
7
n
o
3
.O
3
U
N
a
.p
CD
-a
O
n
D D
N
p
m
m
O
CD
O
a
v
CD
0
(D
a
A
N
.A
O
W
w
W
0)
W
A
W
N
W
O
N
OO
N
N
-D.N
N
N
CD
oo
A
N
CD
00
m
?
N
0
v
CT
W
-D
co
-.4
Cn
W
—
CO
--J0
W
�
CO
J
cn
W
—
(D
n
x
x
0
v,
=r0
r
0
0
0
'o.
o.
°c
o
o
o
m
Q
-i
�
m
m
o
o
O
p
O
o
0
C7 o0 D
770
0
o
a
w
v
CD
m
oCD
m
0 3=F 3
70
O (A (n N
0
o
�
�
j
N
:3
O
(�°�mmm
:3
60 0 0 0
Cl 7
fD
3 0 0 0
-0 (D CD CD M
CD as as
m a a a a
O
O
O
O
G
�JOp Op (Q
V
V
V
J
V
V
O
O
O
O
O
O
O
O
A
O
A
O
A
O
A
O
N
W
N
O]
N
co
V
N
O
W
tD
cr,
c0
m
O
N
W Lrl OD — Ul
(Y) N — W CO
0
m 7< T 7c
p<j p<j p<j p<j
m
m
m
m
m
m
m
m
m
m
m
m
m
m
m
m
m
m
CL
CD
N
N
N
N
W
Ul
O
W
[T
O
W
Vl
O
W
W
O
N
W
O
Nm
W
O
W
O
N
W
O
N
W
O
N
W
O
W
O
N
N
O
W
N
O
W
N
O
W
N
O
O
O
O
O
-�
N
N \ \
w rn\ v, o\o o\o o
O
D
`♦
c�
Q
m
n
o
m
n
o
w
n
Q
w
n
Q
w
n
o
m
n
v
m
$
� N O\O O\O O a
Co
m
V N CT 0 0 0 0 0 0 0
IMEMN
X
0 0 0 0 0 0 CD O a
O Cn N O O O O O O O
A-
n
V
Q
C
C
Z
m T. ° r
N
•
0 n ° ° m T. O G7 G7
D m T v D
-'
N
zz9K°oM�0xmm
O
Z Z D D 0
�MM22 �mmZ
N
n n 0 0 z (n �l DI m m Z
O
m
m n
m m K Z
00
<
<
o
00 o o K° D D_
� 00
D � oo � � m m m�
o m a
r
o m A�
r Z nP U)m O o
v
-i N O y o o
Z10
a
o m p T
cnmX
N
n
a cn
=,
--i
�.
C:)
o
0
D D
N
N
4
O
W
00
W
O)
W
A
W
N
LOIN)
O
100
N
0)
N
-N
N
N
N
O
OO
0)
.A
N
O
Op
A
N
,HERMIT CORD COPY
PLAN REVIEW/ROUTING SLIP
PERMIT NUMBER: EL16-0800 DATE: 09/07/16
PROJECT NAME: 85C BAKERY AND CAFE
SITE ADDRESS: 1350 SOUTHCENTER MALL
X Original Plan Submittal Revision # before Permit Issued
Response to Correction Letter # Revision # after Permit Issued
DEPARTMENTS:
Building Division Fire Prevention
Public Works ❑ Structural
PRELIMINARY REVIEW:
Not Applicable ❑
(no approval/review required)
REVIEWER'S INITIALS:
APPROVALS OR CORRECTIONS:
Approved ❑
Corrections Required ❑
(corrections entered in Reviews)
Notation:
REVIEWER'S INITIALS:
❑ Planning Division ❑
❑ Permit Coordinator ❑
DATE: 09/08/16
Structural Review Required ❑
DATE:
DUE DATE: 10/06/16
Approved with Conditions
Denied ❑
(ie: Zoning Issues)
DATE:
Permit Center Use Only
CORRECTION LETTER MAILED:
Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials:
12/18/2013
MERIT ELECTRIC INC
Home Espanol Contact
Safety & Health
Washington State Department of
Labor & Industries
MERIT ELECTRIC INC
Page 1 of 3
Search L&I
A-! Index Help Mi L&I
Claims & Insurance Workplace Rights Trades & Licensing
Owner or tradesperson 12201 CYRUS WAY STE 105
MUKILTEO, WA 98275
Principals 425-315-8840
LANUM, JACK D, PRESIDENT SNOHOMISH County
LANUM, LAURA C, VICE PRESIDENT
EVERSON, CHRISTINA M, SECRETARY
RONALD G HOUSH, AGENT
DEFAYE, PHILIPPE MARC, PRESIDENT
(End: 01/11/2010)
WILSON, CHRISTINA, SECRETARY
(End: 01 /11/2010)
DEFAYE, PHILIPPE MARC, TREASURER
(End: 01 /11/2010)
Doing business as
MERIT ELECTRIC INC
WA UBI No. Business type
601 680 785 Corporation
Governing persons
JACK
D
LANUM
PHILLIPPE M DE FAYE;
License
Verify the contractor's active registration / license / certification (depending on trade) and any past violations.
.Electrical..........Contractor.......Active.
........................... .
Meets current requirements.
License specialties
GENERAL
License no.
MERITE1044BQ
Effective — expiration
01/18/1996— 01/2012018
Designated administrator
LANUM, JACK D
License type
Master Electrician
Bond
............
CBIC
Bond account no.
SH3803
Received by L&I
08/27/2007
Active.
Meets current requirements.
License no.
LANUMJD978D4
$4,000.00
Effective date
06/14/2007
Expiration date
Help us improve
https:Hsecure.Ini.wa.gov/verify/Detail.aspx?UBI=601680785&LIC=MERITEI044BQ&SAW= 9/15/2016
GENERAL NOTES
1. ALL WORK SHALL CONFORM TO APPLICABLE CURRENT FEDERAL, STATE AND LOCAL CODES. THE CONTRACTOR IS TO PROVIDE FOR ALL
REQUIRED NOTIFICATION OF AND COORDINATION WITH THE CITY AND STATE AGENCIES, AND PROVIDE REQUIRED PERMITS. ALL TESTS AND
INSPECTIONS ASSOCIATED WITH OBTAINING APPROVALS TO PROCEED WITH AND COMPLETE THE WORK SHALL BE PAID FOR BY THE
CONTRACTOR.
2. THE CONTRACTOR SHALL COORDINATE WITH THE OWNER, INCLUDING AREA FOR WORK, MATERIALS STORAGE, ACCESS TO AND FROM THE
WORK, SPECIAL CONDITIONS OR NOISY WORK, TIMING OF WORK AND INTERRUPTIONS OF MECHANICAL AND ELECTRICAL SERVICES.
3. ALL WORK SHALL BE PERFORMED IN ACCORDANCE WITH THE HIGHEST STANDARD OF WORKMANSHIP IN GENERAL AND WITH SUCH
STANDARDS AS ARE SPECIFIED.
4. CONTRACTOR SHALL VERIFY ALL DIMENSIONS AND CONDITIONS ON SITE AND NOTIFY DESIGNER/ARCHITECT OF ANY DISCREPANCIES.
CONTRACTOR IS NOT TO SCALE OFF DRAWINGS.
5. CONTRACTOR SHALL PROVIDE 16 GAUGE SHEET METAL BACKING IN PARTITIONS FOR ALL WALL MOUNTED FIXTURES AND DEVICES UNLESS
INDICATED OTHERWISE ON THE DRAWINGS.
6. ALL MATERIALS INDICATED TO MATCH EXISTING SHALL DO SO WITH RESPECT TO SIZE, COLOR, TEXTURE, PATTERN, QUALITY AND METHOD
OF INSTALLATION INSOFAR AS PRACTICABLE AND SHALL BE APPROVED BY THE DESIGNER/ARCHITECT BEFORE USE.
7. EXISTING WORK DAMAGED AS A RESULT OF WORK UNDER THIS CONTRACT SHALL BE REPAIRED TO ORIGINAL CONDITION AND FINISHED TO
MATCH ADJACENT FINISHES, SUBJECT TO OWNER'S APPROVAL, AT NO ADDITIONAL COST TO OWNER. ALL REPLACEMENT MATERIAL REQUIRED
TO MATCH EXISTING MATERIALS SHALL DO SO WITH RESPECT TO TYPE, PATTERN, TEXTURE, SIZE, SHAPE, COLOR AND METHOD OF
INSTALLATION INSOFAR AS PRACTICAL, AND SHALL BE APPROVED BY THE DESIGNER/ARCHITECT AND OWNER PRIOR TO INSTALLATION.
8. ALL EXISTING MECHANICAL AND ELECTRICAL EQUIPMENT AND SERVICE DISRUPTED OR REMOVED DURING CONSTRUCTION SHALL BE
RESTORED AND REPLACED UNLESS NOTED OTHERWISE.
9. INSTALLATIONS OF MECHANICAL, ELECTRICAL AND STRUCTURAL SYSTEMS WILL REQUIRE OPENING OF SOME EXISTING WALLS, CEILINGS,
OR FLOOR CAVITIES. THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE REPAIR OF THESE OPENINGS TO MATCH EXISTING, EXCEPT WHERE
NOTED OTHERWISE. FILL ALL HOLES AND VOIDS IN FLOORS, WALLS AND CEILINGS WHICH RESULT FROM INSTALLATION OF WORK, AND
REMOVAL OF EXISTING MATERIALS AND EQUIPMENT REQUIRED BY THIS CONTRACT. PATCHED AREAS SHALL MATCH THE MATERIALS,
FINISHES, AND LEVELS ADJACENT, OR SHALL BE PUT IN THE PROPER CONDITION TO RECEIVE THE FINISH INDICATED.
10. MATERIALS, ARTICLES, DEVICES AND PRODUCTS ARE SPECIFIED IN THE DOCUMENTS BY LISTING ACCEPTABLE MANUFACTURERS OR
PRODUCTS, BY REQUIRING COMPLIANCE WITH REFERENCED STANDARDS OR BY PERFORMANCE SPECIFICATIONS. FOR ITEMS SPECIFIED BY
NAME, SELECT ANY PRODUCT NAMED. FOR THOSE SPECIFIED BY REFERENCE STANDARD OR BY PERFORMANCE SPECIFICATIONS SELECT ANY
PRODUCT MEETING OR EXCEEDING SPECIFIED CRITERIA. FOR APPROVAL OF AN ITEM NOT SPECIFIED, SUBMIT FOUR (4) COPIES OF COMPLETE
BACK-UP INFORMATION FOR PURPOSES OF EVALUATION. WHERE BUILDING STANDARD ITEMS ARE CALLED FOR, NO SUBSTITUTE WILL BE
ACCEPTED.
11. CONTRACTOR SHALL PROVIDE FOR ALL WORK REQUIRED TO MAINTAIN COMPLIANCE WITH LOCAL FIRE CODE.
12. MECHANICAL AND ELECTRICAL FIXTURES, OUTLETS, ETC. WHEN SHOWN ON THE ARCHITECTURAL DRAWINGS ARE FOR LOCATION
INFORMATION ONLY. MECHANICAL AND ELECTRICAL TO BE DESIGNED BY OTHERS. ALL CIRCUITING COORDINATION TO BE BY OTHERS.
13. CONTRACTOR SHALL COORDINATE WITH OWNER FOR APPROVAL OF LOCATIONS OF ALL HVAC THERMOSTATS, GRILLES, AND DIFFUSERS,
FIRE AND SMOKE DETECTION DEVICES INCLUDING SPRINKLERS, FIRE EXTINGUISHERS AND HOSE CABINETS ETC.
14. ANY CHANGE IN LIGHT FIXTURE PLACEMENT DUE TO INTERFERENCE OF MECHANICAL OR STRUCTURAL COMPONENTS SHALL BE
APPROVED BY OWNER.
15. ALL FLOORS SHALL BE LEVEL. THE CONTRACTOR SHALL BE RESPONSIBLE FOR CORRECTING ANY CONDITIONS THAT DO NOT MEET THIS
STANDARD.
16. FLOOR FINISH TRANSITIONS SHALL OCCUR UNDER DOORS, UNLESS SHOWN OR NOTED OTHERWISE.
17. MECHANICAL, PLUMBING & ELECTRICAL SHALL BE DESIGN BUILD UNLESS OTHERWISE REQUIRED BY LOCAL JURISDICTION.
18. MECHANICAL, PLUMBING & ELECTRICAL DESIGN BUILD. PROVIDE SCHEMATIC DRAWINGS TO OWNER FOR REVIEW AND WRITTEN APPROVAL.
PROVIDE OPERATIONAL AND MAINTENANCE MANUAL TO OWNER PRIOR TO CLOSE OUR OF JOB AND FINAL PAYMENT.
19. THE DESIGNER/ARCHITECT AND/OR THE OWNER WILL NOT BE RESPONSIBLE FOR CONSTRUCTION MEANS, METHODS, TECHNIQUES,
SEQUENCES OR PROCEDURES, OR FOR THE SAFETY PRECAUTIONS OR PROGRAMS IN CONNECTION WITH THE WORK. THE
DESIGNER/ARCHITECT AND/OR THE OWNER WILL NOT BE RESPONSIBLE FOR THE ACTS OR OMISSIONS OF ANY CONTRACTORS,
SUBCONTRACTORS, OR ANY OF THEIR AGENTS OR EMPLOYEES, OR ANY OTHER PERSONS PERFORMING ANY OF THE WORK.
20. CONTRACTOR SHALL PROVIDE AIR BALANCING BY AN INDEPENDENT AIR BALANCING FIRM.
21. CONTRACTOR SHALL SUBMIT SHOP DRAWINGS FOR ALL CASEWORK, SPECIALTY WALL TREATMENTS, FLOOR PATTERNS, STONE
INSTALLATIONS AND COUNTERTOPS FOR REVIEW AND APPROVAL BY DESIGNER/ARCHITECT.
22. CONTRACTOR SHALL ACQUIRE PUBLIC WORKS APPROVAL PRIOR TO PERFORMING ANY WORK WITHIN THE CITY RIGHT-OF-WAY (SIDEWALK
OR ROAD).
MECHANICAL AND ENERGY NOTES
1. ELECTRICAL DESIGN AND INSTALLATION TO BE PER 2014 SEATTLE ELECTRICAL CODE. WORK TO BE UNDER SEPARATE PERMIT.
2. PLUMBING DESIGN AND INSTALLATION TO BE PER 2012 SEATTLE MECHANICAL CODE. WORK TO BE UNDER SEPARATE PERMIT.
3. HEATING DESIGN AND INSTALLATION SHALL CONFORM TO 2012 SEATTLE MECHANICAL CODE.
4. INDOOR DESIGN TEMPERATURES SHALL BE 70 DEGREES F. FOR HEATING AND 78 DEGREES F. FOR COOLING. ALL GLASS TO BE INSULATING
TYPE, THICKNESS AS DESIGNED BY MANUFACTURERS.
5. ALL OPENINGS TO BE CAULKED, WEATHERSTRIPPED, OR SEALED. TEARS AND JOINTS IN BATT INSULATION TO BE SEALED WITH TAPE.
6. HEATING AND VENTILATION SYSTEM TO BE COMPRISED OF A SUPPLY AND RETURN AIR SYSTEM. SYSTEM TO BE FORCED AIR.
LEGEND
1 _--- ELEVATION
A
4A3.0 2 INTERIOR
SHEET ELEVATION
3
NUMBER 1
2 DETAIL A
DETAILS
A1.2 SHEET
NUMBER
CEILING
2
SECTION ACT TYPE
BUILDING 9'-0"
A1.2 SECTIONS CEILING
SHEET HEIGHT
NUMBER
(DD
ABBREVIATIONS
ACT = ACOUSTICAL CEILING TILE
AFP = ACOUSTICAL FABRIC PANEL
AFF = ABOVE FINISHED FLOOR
CW = COLD WATER
EX = EXPLOSION PROOF
CFCI = FURNISHED & INSTALLED BY CONTRACTOR
OFOI = FURNISHED & INSTALLED BY OWNER
OFCI = FURNISHED BY OWNER INSTALLED BY CONTRACTOR
FIN = DIMENSION TO FINISHED FACE OF WALL
FRP = FIBERGLASS REINFORCED PANEL
FS = FLOOR SINK
GWB = GYPSUM WALL BOARD
HM = HOLLOW METAL
HW = HOT WATER
LRV = LIGHT REFLECTANCE VALUE
NIC = NOT IN CONTRACT
PC = POWDER COAT
RCP = REFLECTED CEILING PLAN
TBD = TO BE DETERMINED
TYP = TYPICAL
UNO = UNLESS NOTED OTHERWISE
WP = WEATHER PROOF
+46" = INDICATES HEIGHT ABOVE FINISHED FLOOR
OR ABOVE FINISHED GRADE TO TOP OF DEVICE.
INDEX OF DRAWINGS
A1.0
NOTES, PROJECT INFORMATION, SITE PLAN
A1.1
PROJECT SPECIFICATIONS
A2.0
CONSTRUCTION PLAN
A2.1
FINISH PLAN
A3.0
REFLECTED CEILING PLAN
A4.0
ELEVATIONS
A4.1
INTERIOR ELEVATIONS
A4.2
STOREFRONT DETAILS
K-1
KITCHEN EQUIPMENT PLAN
K-2
EQUIPMENT SCHEDULE
K-3
EQUIPMENT ELECTRICAL PLAN
K-4
EQUIPMENT PLUMBING PLAN
K-5
EQUIPMENT WALL BACKING PLAN
PROJECT DESCRIPTION
INTERIOR TENANT IMPROVEMENT FOR A RETAIL FOOD SERVICE
CODE INFORMATION
BUILDING CODES: 2012 INTERNATIONAL BUILDING CODE
IT IS INTENDED THAT THE ABOVE CODES & REGULATIONS REFER TO THE LATEST
EDITION OR REVISION IN FORCE ON THE DATE OF THESE DRAWINGS.
PROJECT & BUILDING INFORMATION
PROJECT ADDRESS:
ASSESSOR'S PARCEL NUMBER:
LEGAL DESCRIPTION:
ZONING:
TYPE OF CONSTRUCTION:
PROJECT AREA:
TOTAL STORIES:
PROJECT STORY:
FIRE SPRINKLERED:
OCCUPANCY LOAD
TOTAL OCCUPANCY:
DIAGRAM SUMMARY:
BATHROOMS -N/A
ASSEMBLY (FOH) - 26.6
BUSINESS - 8.4
KITCHEN -10.7
STORAGE - 3.7
OCCUPANCY GROUP:
NUMBER OF EXITS REQUIRED:
85 DEGREES BAKERY AND CAFE
1376 SOUTHCENTER MALL
TUKWILA, WA 98188
TUC -RC
I -A
4990 S.F.
1
1 ST FLOOR
YES
49.4 ( REFER TO OCC. DIAGRAM)
IIB
2
CONTACT INFORMATION
APPLICANT: CHIN-LEY/RECHE ASSOCIATES
1516 MELROSE AVENUE
SUITE 200
SEATTLE, WA 98122
CONTACT: SERGIO CHIN -LEY
TEL: 206.938.1501
FAX: 206.935.3449
EMAIL: sergio@chinleyreche.com
TENANT: EVERGREENS
ARCHITECT/DESIGNER: CHIN-LEY/RECHE ASSOCIATES
1516 MELROSE AVENUE
SUITE 200
SEATTLE, WA 98122
CONTACT: SERGIO CHIN -LEY
TEL: 206.938.1501
FAX: 206.935.3449
EMAIL: sergio@chinleyreche.com
BATHROOM PLUMBING FIXTURES
TOTAL OCCUPANTS: 49.4
OCCUPANTS PER GENDER: 49.4/2 = 24.7
PER TABLE 29, IBC, 2012, 1 TOILET/1 LAV REQUIRED PER GENDER
,M,X, 1 E PERMIT
REO'iRED FOR:
W"20chanical
❑ C'actrixf
8umb`ng
W -13s Poing
City f Tukwila
A_Di .G DIVIStnnr
PROJECT SITE
\/lr--lKIITV AAUP
_..., t-- c�=jproval of
I �:3 B111lding Division.
4Viii re r
in ;ude i'll Mquim a nety plan submittal
,.J't
Plan review fees.
( I7I• I I,
Permit a ...EL _ V VO
Flan revievi appr0vR1 is subject to errors and orn!ssions.
Approval of cor is nicfion documents does not auiholiZe
the violattion of any adopted code or ordinance. RocGipt
of approved ioid �' and condi' ns is acknowledned:
Qy:
City Of Tukwila
BUILDING DIVISION
-10.7
1
OCCUPANCY DIAGRAM
N
SCALE: 1/8"= V-0"
REVIEWED FOR
'34MPLIANCE WITH
NFPA70 - NEO
SEP 13 2016
Chin-Ley/Reche
1516 Melrose Ave., Suite 200
Seattle, Washigton 98122
206 938 1501
project title:
85 Degrees Bakery and Cafe
Southcenter
1376 Southcenter Mall
Tukwila, WA 98188
date: description:
05.02.16 progress
06.13.16 Dermit
date:
June 13, 2016
yawing if •CE V
PROJWTI 19GUE19EM I LA
SEP 31 2016
PERMIT CENTER
number
mum
REFLECTED CEILING GENERAL NOTES
_ 1. FIRE SPRINKLER SHUT DOWN, DRAIN AND FIRE WATCH REQUIRED DURING ALL
SCOPE OCCURRING AT, IN AND ABOVE CEILING AREAS. FS SHUT DOWN PROCESS TO
BE ENGAGED UNTIL ALL FIRE SPRINKLER LINES AND HEADS ARE PERMANENTLY
INSTALLED AND AFFIXED.
2. ACT SPECIFICATION TO BE TO COMMERCIAL KITCHEN -GRADE, VINYL, WHITE,
SMOOTH AND CLEANABLE.
3. FIRE ALARM TO BE WITH WHITE TRIMS.
4. FIXTURES WITH SYMBOL " ** "DENOTES EMERGENCY AND PATHWAY LIGHTING
REFLECTED CEILING PLAN KEY NOTES
O EXISTING STOREFRONT HEADER WALL
O PROTECT EXISTING DEMISING WALL, TYP.
O RESERVED
O HEADER WALL, REFER TO ELEVATIONS
O RESERVED
O RESERVED
O RESERVED
12 GA. SPLAY WIRES WITH
MINIMUM 4 TIGHT TURNS IN
1 1/2" BOTH ENDS OF
WIRE-TYP.
CROSS RUNNER
MAIN RUNNER
DISTANCE FROM BRADING —
WIRES TO RUNNERS
NOTE:
LATERAL BRACING IS NOT
REQUIRED FOR PLENUMS LESS
THAN 12" TO STRUCTURE OR
CEILINGS LESS THAN 1,000 S.F.
PROVIDED THEY ARE
SURROUNDED BY FOUR WALLS
AND BRACED TO STRUCTURE.
12 GA. VERTICAL HANGER WIRE @
4'-0" EACH WAY WITH MINIMUM 3
TIGHT TURNS WITHIN 3" BOTH
ENDS OF WIRE
SEISMIC COMPRESSION
STRUT TO BE 12'-0" O.C.
AND TO BEGIN NO
FARTHER THAN 6'-0" FROM
THE WALLS.
fttiu�
COMPRESSION STRUT SCHEDULE
EMT CONDUIT
Y2" EMT CONDUIT
UP TO 6'-0"
EMT CONDUIT
UP TO 8'-6"
1" EMT CONDUIT
UP TO 10'-0"
EMT CONDUIT
1 Va" METAL STUD (25 GA)
UP TO 6'-2"
2-1/2" METAL STUD (25 GA)
UP TO 10'-6"
NOTE: PLENUM AREAS GREATER THAN 11'-0" WILL REQUIRE ENGINEERING
CALCULATIONS.
0)DSCLAL_Al-l/2"=
CT SEISMIC BRACING
V-0"
y
SHOT IN ANCHOR
CEILING CLIP
12 GA. HANGER WIRE @ 4'0.C. ALL WIRES TO
BE THREE TIGHT TURNS AROUND ITSELF
WITHIN 3 INCHES.
1 !"CARRYING CHANNEL
@ 4'-0" O.C.
ACOUSTICAL TILE CEILING
WALL MOLDING (PERIMETER CLOSURE ANGLE)
TO BE 2" MIN. HORIZ. WIDE FLANGE. THE
CEILING GRID TO BE ATTACHED TO THE WALL
MOLDING AT TWO ADJACENT WALLS AND
SHALL HAVE A%" CLEARANCE AT
UN -ATTACHED WALLS AND BE FREE TO SLIDE.
QISETI�E:
YPACT SEISMIC BRACING
3" = 1'-0"
5,, \AAV
SWITCHING LEGEND
WOC WALL OCCUPANCY SENSOR
D DIMMER
S SINGLE POLE SWITCH
DL DAY LIGHT HARVESTING SENSOR
�A.•1•L.iM:faLiZ
'P'•'•••••••��
•y;.er •Ill
s
EXIT
S =F
MEN
/ 121 B-1 / Q B-1
11 1 D D
� l
\ ,g
\ —1
G
9 HX
B-1 n G B-1
� H
I � i
WQMEN
122
0 B -1S B-1
S GE G
12 –
E
ACT
B-3 B-3
sS
\E1 X* -*E
B-3 N N A B-3
B-3
E
** E \I I V E
W/I
11
SEATING
101
B-1
GWB
12 –0
LIGHTING FIXTURE SCHEDULE
CODE
DESCRIPTION
VENDOR OR MANUFACTURER & MODEL
FINISH
BULB
LAMPS
WATTS
1195
NOTES
:9 A
A
LINEAR LED TRACK LIGHTING
JUNO / TRAC MASTER / AVANT GARDE / ARC 13W LED / T271L27HCNBL
WHITE
LED
13W
E
107
B
PENDANT
Owner Provided
GREEN
LED
13W
78
date:
WnfiMMIB
�--i C
Strip Fixture
'Single Lamp Strip in Cove around Sales Area
WHITE
FLUORESCENT
32W
384
(Y.0
I D
RECESSED DOWNLIGHT
MAXILUME / HH6-LED / 6" ARCHITECTURAL / 900 LUMEN
WHITE
LED
12W
312
HERMIT CENTER
®E
2X4 FLUORESCENT RECESSED
LITHONIA / GENERAL PORPOSE T8 TROFFER / GT8 2X4
WHITE
FLUORESCENT
32W
2,304
GT8 2X2 for E 2X2
EDF
ILLUMINATED EXIT SIGN AND BACKUP
LITHONIA / QUANTUM THERMOPLASTIC EXIT
WHITE
FLUORESCENT
–
–
G
SCONCE
Owner Provided
Green
LED
law
26
----------------------,
B-5
TORAG
116
_LE
B-5
/
XE
B-5
TOTAL WATTS SPECIFIED = 911
1. CONTRACTOR SHALL VERIFY CATALOG PLUMBER WITH FIXTURE DESCRIPTIONS AND PROVIDE PRESCRIBED MODIFICATIONS.
2. CONTRACTOR SHALL SUBMIT CUT SHEETS AND DESCRIPTIONS FOR APPROVAL PRIOR TO PURCHASE.
EXIT F ui E= F
DL MAT
B-1 O B-1 O B-1 B-1
D D D D
O B-1
TI D
O B-1 B-1 GWB c)13-1
D D 14 –0 D
DL
O B-1 O B-1
D D
SEATING
102
I, D -1 Op -1 TI
B-1
0
BR
AD FINISH
IS
D
/ r--
-1
O B-1
B-1 O B-1
oB-1 B-1 SALES B-1
F -1-03 ]C)
B-5
E
107
D
D D
D D
B-5
U)
date:
WnfiMMIB
0
\.ddrawing
title
(Y.0
_
REFLECTED CE!6fi t -F a*
CET`: OF TUKWiLA
0
SEP 0 1 2016
LL
HERMIT CENTER
E
B-5XE
B-5
**E
KE
RSV
B-5
BREAD
10
BAKE
RSV
77
----------------------,
B-5
TORAG
116
_LE
B-5
/
XE
B-5
r-------------------
E!
OB-7
OB -7
OB -7
B-7 O B-7
B
B
YSD
i B B
i-----------------------
L — — — — — — — — — — — — — — — — — —
SERVICE
ESPRESSO
10 0
106
A**
105
A
A A A
TI
B-1
B-1
(:f) B-1 B-1 B-1
r
'
_
------------------------------------
ss
'
B-3
** E
B-5
sv B-3 B-3 B-3 B-3 B-3 B-5
C K ORATI N
DRIN PREP RSV
111
ACT
110 '
VE ME XE
1C, _�
BREAD P E
E
E
** E
10 E
-5
B-3 I I t I N AB -5 N AB
A
E E\
B-3 S KULLEF
113
:IN C
118
-11
E \I
S
B-3
MANF
**E
**
E
■
IW=
E \I I V ** E
11 119 1
E
GWB
12 –0
MAT
SALES
104
E
REVIEWED AOR
COMPLIANCE WITH
NFRA, 70 r NEC
SEP 13 2016
City of-Tulw'iIla. --
BUILDING DIVISION
SCALE: 1/4" =1'
Chin-Ley/Rwhe
1516 Melrose Ave., Suite 200
Seattle, Washigton 98122
206 938 1501
project title:
85 Degrees Bakery and Cafe
Southcenter
1376 Southcenter Mail
Tukwila, WA 98188
date: description:
05.02.16 progress
06.13.16 permit
0
BR
AD FINISH
E
B-5
E
107
RSV
E
B-5
**E
B-5
U)
date:
WnfiMMIB
0
\.ddrawing
title
(Y.0
_
REFLECTED CE!6fi t -F a*
CET`: OF TUKWiLA
0
SEP 0 1 2016
LL
HERMIT CENTER
E
B-5XE
B-5
**E
KE
RSV
B-5
BREAD
10
BAKE
RSV
77
KE
B-5
TORAG
116
_LE
B-5
XE
B-5
E
REVIEWED AOR
COMPLIANCE WITH
NFRA, 70 r NEC
SEP 13 2016
City of-Tulw'iIla. --
BUILDING DIVISION
SCALE: 1/4" =1'
Chin-Ley/Rwhe
1516 Melrose Ave., Suite 200
Seattle, Washigton 98122
206 938 1501
project title:
85 Degrees Bakery and Cafe
Southcenter
1376 Southcenter Mail
Tukwila, WA 98188
date: description:
05.02.16 progress
06.13.16 permit
0
:D
U)
date:
WnfiMMIB
0
\.ddrawing
title
(Y.0
_
REFLECTED CE!6fi t -F a*
CET`: OF TUKWiLA
0
SEP 0 1 2016
LL
HERMIT CENTER
number
o-0
SUPPLIER DESCRIPTION ELECTRICAL PLUMBING
C5 u') f- o
cn z
J (n cn
w LqU I- O = O O O Q Q I- w
'_ _12c) o c� •ac = > n- v ELECTRICAL NOTES _ z u 3:: CID m PLUMBNG NOTES �-
12.
1
1
0lmmml�i
PARE NUMBER
MJMM=lel
PARE
SPARE
111111MI'SPARE NUMBER
j�1=1111IMM1111=111SPARE
NUMBER
1 .. I===ISI
SPARE NUMBER
NUMBER
IG
itI
1. THE ELECTRICAL CONTRACTOR SHALL SUPPLY AND INSTALL SEAL-TITE FLEX CONDUIT TO ALL FOOD SERVICE
EQUIPMENT IN DAMP AREAS, I.E., SCULLERY, BAR ROOF, ETC. FLEX CONNECTIONS AT ALL FANS ON THE
ROOF SHALL BE OF EXTRA LENGTH TO ALLOW FULL FAN REMOVAL FOR THE EASE OF CLEANING.
2. THE ELECTRICAL CONTRACTOR SHALL PROVIDE FUSED DISCONNECTS FOR EQUIPMENT HOOK-UPS AS
REQUIRED BY CODE AND LABELING.
3. THE ELECTRICAL CONTRACTOR SHALL PROVIDE DISCONNECTS IN A CONVENIENT ACCESSIBLE LOCATION AT
AT THE POWER BOX FOR EACH ICE MACHINE HEAD.
4. THE ELECTRICAL CONTRACTOR SHALL PROVIDE AND INSTALL AN INTERCONNECT CIRCUIT BETWEEN THE ICE
MACHINE HEADS (ITEM 39) AND THE REMOTE CONDENSING UNITS ON THE ROOF AS REQUIRED BY THE
MANUFACTURER.
5. THE ELECTRICAL CONTRACTOR SHALL PROVIDE AND INSTALL A VAPOR -PROOF SWITCH AT EACH
BLOWER COIL IN THE WALK-IN COOLER (ITEM 32.1, 32.3, AND 33.1).
8. THE ELECTRICAL CONTRACTOR SHALL PROVIDE AND INSTALL A 48" MINIMUM CORD AND PLUG
FOR EACH PIECE OF EQUIPMENT SO NOTED. USE 90i ELBOW OUT OF UNIT.
10. THE ELECTRICAL CONTRACTOR SHALL PROVIDE FOR HOOK-UP OF A THERMOSTAT, SOLENOID, BLOWER
COIL AND COMPRESSOR FOR EACH REFRIGERATED UNIT. MAGNETIC STARTERS AND/OR THERMAL
PROTECTORS SHALL BE INCLUDED AS NECESSARY.
11. THE ELECTRICAL CONTRACTOR SHALL PROVIDE 1" CONDUIT AND JUNCTION BOXES AT EACH CASH
REGISTER TERMINAL SO AS TO INTERCONNECT ALL UNITS TO EACH OTHER AND TO THE CENTRAL
PROCESSING TERMINAL. CONSULT WITH THE OWNER'S REPRESENTATIVE FOR EXACT LOCATIONS OF ALL
TIE-IN UNITS.
13. THE PLUMBING CONTRACTOR SHALL PROVIDE AND INSTALL ALL DRAIN LINES FROM WALK-IN
BLOWER COILS TO FLOOR SINKS. HEAT TAPE SHALL BE PROVIDED AND WRAPPED AT ALL
DRAIN LINES SUBJECT TO THE POSSIBILITY OF FREEZING, SUPPLIED AND INSTALLED BY ELECTRICAL
CONTRACTOR.
14. ALL DRAIN LINES FROM EQUIPMENT REQUIRING CONDENSATION REMOVAL SHALL BE DONE IN
COPPER.
15. IT SHALL BE THE RESPONSIBILITY OF "OTHERS" TO INTERCONNECT THE HOOD FIRE PROTECTION
SYSTEMS TO THE BUILDING FIRE DETECTION UNITS AS REQUIRED.
19. THE ELECTRICAL CONTRACTOR SHALL SUPPLY AND INSTALL TO EACH PIECE OF ROOF -TOP EQUIPMENT
(FANS, MOTORS, COMPRESSORS, CONDENSERS, ETC.) A SEPARATE WEATHER -PROTECTED DISCONNECT
SWITCH.
22. IT SHALL BE THE RESPONSIBILITY OF THE PLUMBING AND ELECTRICAL CONTRACTORS TO MAKE
ALL REQUIRED WATER, GAS, DRAIN AND ELECTRICAL FINAL CONNECTIONS FOR ALL MAKE-UP AIR
SYSTEM UNITS.
23. IT SHALL BE THE RESPONSIBILITY OF THE ELECTRICAL CONTRACTOR TO INSTALL ALL OWNER
SUPPLIED COMPUTER/COMMUNICATIONS CABLES AS PER OWNERS DIRECTION.
24. IT SHALL BE THE RESPONSIBILITY OF PLUMBING CONTRACTOR TO COMPLY WITH ALL LOCAL CODES
CONCERNING GAS VALVE REGULATOR VENTING.
25. ELECTRICAL CONTRACTOR SHALL PROVIDE A INDIVIDUAL DISCONNECT BOX FOR EACH PIECE OF
ROOF TOP ELECTRICALLY POWERED EQUIPMENT.
26. THE GENERAL CONTRACTOR SHALL PHOTOGRAPH ALL WALLS CONTAINING BACKING PRIOR TO
SHEETROCK/FRP INSTALLATION.
27. THE PLUMBING CONTRACTOR SHALL PROVIDE CLEANOUTS AT 1ST ELBOW ON EACH WALK-IN
BLOWER COIL DRAIN.
29. THE PLUMBING CONTRACTOR SHALL SUPPLY AND INSTALL WATER LINE BACK CHECK VALVES AS
REQUIRED PER CODE.
30. THE ELECTRICAL CONTRACTOR SHALL PROVIDE INTERCONNECT SWITCHING BETWEEN THE KITCHEN
EXHAUST HOOD EXHAUST FANS AND THE KITCHEN MAKE-UP AIR SYSTEMS AS REQUIRED PER
LOCAL CODE AND AUTHORITIES.
31. COMMUNICATIONS CABLES ARE SUPPLIED BY OWNER AND INSTALLED BY ELECTRICAL CONTACTOR.
34. PLUMBING CONTRACTOR TO INSTALL DISPOSER PER MANUFACTURER'S SPEC. SHEET.
35. PRESSURE REGULATORS FOR GAS COOKING EQUIPMENT SUPPLIED BY B/E AND INSTALLED PER
CODE AND MANUFACTURER'S SPECIFICATIONS BY PLUMBING CONTRACTOR.
36. ELECTRICAL CONTRACTOR SHALL PROVIDE INTER CONNECT FOR FREEZER COIL & TIMECLOCK
CIRCUIT DEFROST SYSTEM.
EVI Wc: .
COMPLIANCE WiT'H
gNFP 7O � IIEC
SEP 1 3 2016
city OfTul-nulla
SUILDiNlG DIVISION
T'i E�E;'ti1E:J
,;pfy OF -TUKWILA
Seg' 0 12016
?ERMIT CENTER
N
STORAGE
WH
C-1
CLEANING
STORAGE
Q� __ ___ W
C-33,35,37 x
------ -- — �-
9 +24' G.1
+120' B-��__2__
C- 11,1,3,15 8 B-34
DROP Mj
�a1
�. IR
S/1 �B `
97 B-32
+ 8' 98
13-417
+4s' 98
ZE
X
B-21
64 r�
C-7
Show
Window
B-21
50
. moi/ •
�s �JC� • • c
- - - g +120"
115/1
_D1155
Show
Window
B-25 C48.
B-25 r--\
B-23 4 +24'
B-23 11.
115/1155 ! 1
B-30 +24' 13e+48"' `. ;�. ; B-30 U� B-41 11 +2427 B-30' , n \ h B-2,4 28 +48'1648
\/7 +24' 115/1
V V B-30 155 C-23,25 34 +`�� C-15,1 63
DROP
91
(513-32 B-38,40,42
B 2
DROP CORD
115/1
15A 32 +120
B-24,26,28
r
32
% B-18,20,22
1117 a ._
Television
+120,, B-23
B-23 115/1 j
15A
B-23
+120"
115/1
j+12' + 2'
C-7 B-27 B-27 +124 B-27
Show
Window 115/11
C-7 155
B-29/; .,
R.R . B-27
B-29
B-27
B-29 51� B-27
70C
B-27 B-27 B-27
I r
M r
I 115/1 L_T�
i �---- 155 �
B-41
L I 1
1 ---- q \37,39
L_ -_j L --J
+24(27 B-31
�d �� i
i u v i
iTiil +24ii " 74
• �/
--- 1115
/1 - - �.� - - -� *�
B-31
------------------
B-41 — _ -- — — -33,35 8 +120 `� \ \
I
B-31 �9 —+24'
33.133
B-12,14,16
I
33
B- +120'
31 54
ROOF
SEE ARCHITECT'S DRAWINGS
8 32.2 32.4 33.3 39.1
ELECTRICAL NOTES
1. THE CONTRACTOR SHALL PROVIDE AND INSTALL STAINLESS STEEL OUTLET AND RECEPTACLE
COVERS IN SERVICE AREAS.
3. THE ELECTRICAL CONTRACTOR SHALL CONNECT ALL REMOTE COMPRESSORS AND PROVIDE
DISCONNECTS, MAGNETIC STARTERS, AND THERMAL OVERLOAD PROTECTION AS REQUIRED.
4. THE ELECTRICAL CONTRACTOR SHALL PROVIDE AND INSTALL HEAT TAPE ON DRAIN LINES IN
DANGER OF FREEZING.
5. THE ELECTRICAL CONNECTIONS, SPECIFICATIONS AND DIMENSIONS SHOWN ON THESE PLANS
ARE FOR FOOD SERVICE EQUIPMENT ONLY. SEE THE ARCHITECTS PLAN SET FOR ALL OTHER
ELECTRICAL REQUIREMENTS FOR THIS PROJECT.
6. ALL ELECTRICAL ROUGH -IN WORK AND ALL FINAL CONNECTIONS FOR ALL ITEMS SHOWN AND
SPECIFIED ON THESE PLANS BY CMA SHALL BE PERFORMED BY THE ELECTRICAL
CONTRACTOR.
7. UNLESS OTHERWISE SPECIFIED IN THESE PLANS OR OTHER WRITTEN CONTRACTS, IT SHALL BE
THE RESPONSIBILITY OF THE ELECTRICAL CONTRACTOR TO PROVIDE ALL ELECTRICAL -TYPE
MATERIALS INCLUDING WIRING, SWITCHES, DISCONNECTS, FLEX, CONDUIT, CONTACTORS,
TRANSFORMERS, THERMAL OVERLOAD PROTECTORS, MAGNETIC STARTERS, ELECTRICAL
PANELS, CORDS, PLUGS, COVERS, ETC.
9. ALL DIMENSIONS SHOWN ARE FROM GRID LINES, FINISHED WALLS OR FINISHED FLOORS TO
CENTER LINE OF ELECTRICAL OUTLET BOXES. HEIGHTS ARE NOT TO BE TAKEN FROM CURBS OR
PLATFORMS.
10. THE SYMBOLS SHOWN ON THIS PLAN ARE FOR INDICATION OF ROUGH -IN LOCATION AND TYPE
OF CONNECTION ONLY. THE ELECTRICAL CONTRACTOR SHALL PROVIDE CIRCUITS AND CONDUIT
RUNS AS PER GOOD PRACTICE AND CODE.
11. IT SHALL BE THE RESPONSIBILITY OF THE ELECTRICAL CONTRACTOR TO PROVIDE INTERCONNECT
SWITCHING BETWEEN THE KITCHEN EXHAUST HOOD EXHAUST FANS AND THE KITCHEN MAKE UP AIR
SYSTEMS AS REQUIRED PER LOCAL CODE AND AUTHORITIES.
12. THE ELECTRICAL CONTRACTOR SHALL PROVIDE FUSED DISCONNECTS FOR EQUIPMENT
HOOK-UPS AS REQUIRED BY CODE AND LABELING.
13. ALL GFCI RECEPTACLES SHALL BE LOCATED IN AN ASSESSABLE LOCATION FOR STATIONARY EQUIPMENT.
ELECTRICAL LEGEND.
C=
115 VOLT DUPLEX OUTLET
I
115 VOLT DCO, DEDICATED/ISOLATED
208V SPECIALTY OUTLET
®
JUNCTION BOX
COMMUNICATIONS CABLE VERIFY SPEC'SAQINTWTHD
ON/OFF SWITCH
VERIFY EQUIPMENT REQUIREMENTS WITH FINAL EQUIPMENT SELECTIONS
GFCI RECEPTACLES SHALL BE PASS & SEYMOUR N0. 2095-W
RTU- 30 AMP DISC 480V
NEMA 3R
RT EXHAUST FAN - 30
AMP DISC 480V NEMA
3R
EVIEWED FOH
COMPLIANCE VOTH
NIM _70 - MEG
SEP 1 3 2016
City OfTufaviia.
BUILDING DIVISION
LO
N
GENERAL NOTES
1. ALL WORK SHALL CONFORM TO APPLICABLE CURRENT FEDERAL, STATE AND LOCAL CODES. THE CONTRACTOR IS TO PROVIDE FOR ALL
REQUIRED NOTIFICATION OF AND COORDINATION WITH THE CITY AND STATE AGENCIES, AND PROVIDE REQUIRED PERMITS. ALL TESTS AND
INSPECTIONS ASSOCIATED WITH OBTAINING APPROVALS TO PROCEED WITH AND COMPLETE THE WORK SHALL BE PAID FOR BY THE
CONTRACTOR.
2. THE CONTRACTOR SHALL COORDINATE WITH THE OWNER, INCLUDING AREA FOR WORK, MATERIALS STORAGE, ACCESS TO AND FROM THE
WORK, SPECIAL CONDITIONS OR NOISY WORK, TIMING OF WORK AND INTERRUPTIONS OF MECHANICAL AND ELECTRICAL SERVICES.
3. ALL WORK SHALL BE PERFORMED IN ACCORDANCE WITH THE HIGHEST STANDARD OF WORKMANSHIP IN GENERAL AND WITH SUCH
STANDARDS AS ARE SPECIFIED.
4. CONTRACTOR SHALL VERIFY ALL DIMENSIONS AND CONDITIONS ON SITE AND NOTIFY DESIGNER/ARCHITECT OF ANY DISCREPANCIES.
CONTRACTOR IS NOT TO SCALE OFF DRAWINGS.
5. CONTRACTOR SHALL PROVIDE 16 GAUGE SHEET METAL BACKING IN PARTITIONS FOR ALL WALL MOUNTED FIXTURES AND DEVICES UNLESS
INDICATED OTHERWISE ON THE DRAWINGS.
6. ALL MATERIALS INDICATED TO MATCH EXISTING SHALL DO SO WITH RESPECT TO SIZE, COLOR, TEXTURE, PATTERN, QUALITY AND METHOD
OF INSTALLATION INSOFAR AS PRACTICABLE AND SHALL BE APPROVED BY THE DESIGNER/ARCHITECT BEFORE USE.
7. EXISTING WORK DAMAGED AS A RESULT OF WORK UNDER THIS CONTRACT SHALL BE REPAIRED TO ORIGINAL CONDITION AND FINISHED TO
MATCH ADJACENT FINISHES, SUBJECT TO OWNER'S APPROVAL, AT NO ADDITIONAL COST TO OWNER. ALL REPLACEMENT MATERIAL REQUIRED
TO MATCH EXISTING MATERIALS SHALL DO SO WITH RESPECT TO TYPE, PATTERN, TEXTURE, SIZE, SHAPE, COLOR AND METHOD OF
INSTALLATION INSOFAR AS PRACTICAL, AND SHALL BE APPROVED BY THE DESIGNER/ARCHITECT AND OWNER PRIOR TO INSTALLATION.
8. ALL EXISTING MECHANICAL AND ELECTRICAL EQUIPMENT AND SERVICE DISRUPTED OR REMOVED DURING CONSTRUCTION SHALL BE
RESTORED AND REPLACED UNLESS NOTED OTHERWISE.
9. INSTALLATIONS OF MECHANICAL, ELECTRICAL AND STRUCTURAL SYSTEMS WILL REQUIRE OPENING OF SOME EXISTING WALLS, CEILINGS,
OR FLOOR CAVITIES. THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE REPAIR OF THESE OPENINGS TO MATCH EXISTING, EXCEPT WHERE
NOTED OTHERWISE. FILL ALL HOLES AND VOIDS IN FLOORS, WALLS AND CEILINGS WHICH RESULT FROM INSTALLATION OF WORK, AND
REMOVAL OF EXISTING MATERIALS AND EQUIPMENT REQUIRED BY THIS CONTRACT. PATCHED AREAS SHALL MATCH THE MATERIALS,
FINISHES, AND LEVELS ADJACENT, OR SHALL BE PUT IN THE PROPER CONDITION TO RECEIVE THE FINISH INDICATED.
10. MATERIALS, ARTICLES, DEVICES AND PRODUCTS ARE SPECIFIED IN THE DOCUMENTS BY LISTING ACCEPTABLE MANUFACTURERS OR
PRODUCTS, BY REQUIRING COMPLIANCE WITH REFERENCED STANDARDS OR BY PERFORMANCE SPECIFICATIONS. FOR ITEMS SPECIFIED BY
NAME, SELECT ANY PRODUCT NAMED. FOR THOSE SPECIFIED BY REFERENCE STANDARD OR BY PERFORMANCE SPECIFICATIONS SELECT ANY
PRODUCT MEETING OR EXCEEDING SPECIFIED CRITERIA. FOR APPROVAL OF AN ITEM NOT SPECIFIED, SUBMIT FOUR (4) COPIES OF COMPLETE
BACK-UP INFORMATION FOR PURPOSES OF EVALUATION. WHERE BUILDING STANDARD ITEMS ARE CALLED FOR, NO SUBSTITUTE WILL BE
ACCEPTED.
11. CONTRACTOR SHALL PROVIDE FOR ALL WORK REQUIRED TO MAINTAIN COMPLIANCE WITH LOCAL FIRE CODE.
12. MECHANICAL AND ELECTRICAL FIXTURES, OUTLETS, ETC. WHEN SHOWN ON THE ARCHITECTURAL DRAWINGS ARE FOR LOCATION
INFORMATION ONLY. MECHANICAL AND ELECTRICAL TO BE DESIGNED BY OTHERS. ALL CIRCUITING COORDINATION TO BE BY OTHERS.
13. CONTRACTOR SHALL COORDINATE WITH OWNER FOR APPROVAL OF LOCATIONS OF ALL HVAC THERMOSTATS, GRILLES, AND DIFFUSERS,
FIRE AND SMOKE DETECTION DEVICES INCLUDING SPRINKLERS, FIRE EXTINGUISHERS AND HOSE CABINETS ETC.
14. ANY CHANGE IN LIGHT FIXTURE PLACEMENT DUE TO INTERFERENCE OF MECHANICAL OR STRUCTURAL COMPONENTS SHALL BE
APPROVED BY OWNER.
15. ALL FLOORS SHALL BE LEVEL. THE CONTRACTOR SHALL BE RESPONSIBLE FOR CORRECTING ANY CONDITIONS THAT DO NOT MEET THIS
STANDARD.
16. FLOOR FINISH TRANSITIONS SHALL OCCUR UNDER DOORS, UNLESS SHOWN OR NOTED OTHERWISE.
17. MECHANICAL, PLUMBING & ELECTRICAL SHALL BE DESIGN BUILD UNLESS OTHERWISE REQUIRED BY LOCAL JURISDICTION.
18. MECHANICAL, PLUMBING & ELECTRICAL DESIGN BUILD. PROVIDE SCHEMATIC DRAWINGS TO OWNER FOR REVIEW AND WRITTEN APPROVAL.
PROVIDE OPERATIONAL AND MAINTENANCE MANUAL TO OWNER PRIOR TO CLOSE OUR OF JOB AND FINAL PAYMENT.
19. THE DESIGNER/ARCHITECT AND/OR THE OWNER WILL NOT BE RESPONSIBLE FOR CONSTRUCTION MEANS, METHODS, TECHNIQUES,
SEQUENCES OR PROCEDURES, OR FOR THE SAFETY PRECAUTIONS OR PROGRAMS IN CONNECTION WITH THE WORK. THE
DESIGNER/ARCHITECT AND/OR THE OWNER WILL NOT BE RESPONSIBLE FOR THE ACTS OR OMISSIONS OF ANY CONTRACTORS,
SUBCONTRACTORS, OR ANY OF THEIR AGENTS OR EMPLOYEES, OR ANY OTHER PERSONS PERFORMING ANY OF THE WORK.
20. CONTRACTOR SHALL PROVIDE AIR BALANCING BY AN INDEPENDENT AIR BALANCING FIRM.
21. CONTRACTOR SHALL SUBMIT SHOP DRAWINGS FOR ALL CASEWORK, SPECIALTY WALL TREATMENTS, FLOOR PATTERNS, STONE
INSTALLATIONS AND COUNTERTOPS FOR REVIEW AND APPROVAL BY DESIGNER/ARCHITECT.
22. CONTRACTOR SHALL ACQUIRE PUBLIC WORKS APPROVAL PRIOR TO PERFORMING ANY WORK WITHIN THE CITY RIGHT-OF-WAY (SIDEWALK
OR ROAD).
MECHANICAL AND ENERGY NOTES
1. ELECTRICAL DESIGN AND INSTALLATION TO BE PER 2014 SEATTLE ELECTRICAL CODE. WORK TO BE UNDER SEPARATE PERMIT.
2. PLUMBING DESIGN AND INSTALLATION TO BE PER 2012 SEATTLE MECHANICAL CODE. WORK TO BE UNDER SEPARATE PERMIT.
3. HEATING DESIGN AND INSTALLATION SHALL CONFORM TO 2012 SEATTLE MECHANICAL CODE.
4. INDOOR DESIGN TEMPERATURES SHALL BE 70 DEGREES F. FOR HEATING AND 78 DEGREES F. FOR COOLING. ALL GLASS TO BE INSULATING
TYPE, THICKNESS AS DESIGNED BY MANUFACTURERS.
5. ALL OPENINGS TO BE CAULKED, WEATHERSTRIPPED, OR SEALED. TEARS AND JOINTS IN BATT INSULATION TO BE SEALED WITH TAPE.
6. HEATING AND VENTILATION SYSTEM TO BE COMPRISED OF A SUPPLY AND RETURN AIR SYSTEM. SYSTEM TO BE FORCED AIR.
LEGEND
1 _--- ELEVATION
A
4A3.0 2 INTERIOR
SHEET ELEVATION
3
NUMBER 1
2 DETAIL A
DETAILS
A1.2 SHEET
NUMBER
CEILING
2
SECTION ACT TYPE
BUILDING 9'-0"
A1.2 SECTIONS CEILING
SHEET HEIGHT
NUMBER
(DD
ABBREVIATIONS
ACT = ACOUSTICAL CEILING TILE
AFP = ACOUSTICAL FABRIC PANEL
AFF = ABOVE FINISHED FLOOR
CW = COLD WATER
EX = EXPLOSION PROOF
CFCI = FURNISHED & INSTALLED BY CONTRACTOR
OFOI = FURNISHED & INSTALLED BY OWNER
OFCI = FURNISHED BY OWNER INSTALLED BY CONTRACTOR
FIN = DIMENSION TO FINISHED FACE OF WALL
FRP = FIBERGLASS REINFORCED PANEL
FS = FLOOR SINK
GWB = GYPSUM WALL BOARD
HM = HOLLOW METAL
HW = HOT WATER
LRV = LIGHT REFLECTANCE VALUE
NIC = NOT IN CONTRACT
PC = POWDER COAT
RCP = REFLECTED CEILING PLAN
TBD = TO BE DETERMINED
TYP = TYPICAL
UNO = UNLESS NOTED OTHERWISE
WP = WEATHER PROOF
+46" = INDICATES HEIGHT ABOVE FINISHED FLOOR
OR ABOVE FINISHED GRADE TO TOP OF DEVICE.
INDEX OF DRAWINGS
A1.0
NOTES, PROJECT INFORMATION, SITE PLAN
A1.1
PROJECT SPECIFICATIONS
A2.0
CONSTRUCTION PLAN
A2.1
FINISH PLAN
A3.0
REFLECTED CEILING PLAN
A4.0
ELEVATIONS
A4.1
INTERIOR ELEVATIONS
A4.2
STOREFRONT DETAILS
K-1
KITCHEN EQUIPMENT PLAN
K-2
EQUIPMENT SCHEDULE
K-3
EQUIPMENT ELECTRICAL PLAN
K-4
EQUIPMENT PLUMBING PLAN
K-5
EQUIPMENT WALL BACKING PLAN
PROJECT DESCRIPTION
INTERIOR TENANT IMPROVEMENT FOR A RETAIL FOOD SERVICE
CODE INFORMATION
BUILDING CODES: 2012 INTERNATIONAL BUILDING CODE
IT IS INTENDED THAT THE ABOVE CODES & REGULATIONS REFER TO THE LATEST
EDITION OR REVISION IN FORCE ON THE DATE OF THESE DRAWINGS.
PROJECT & BUILDING INFORMATION
PROJECT ADDRESS:
ASSESSOR'S PARCEL NUMBER:
LEGAL DESCRIPTION:
ZONING:
TYPE OF CONSTRUCTION:
PROJECT AREA:
TOTAL STORIES:
PROJECT STORY:
FIRE SPRINKLERED:
OCCUPANCY LOAD
TOTAL OCCUPANCY:
DIAGRAM SUMMARY:
BATHROOMS -N/A
ASSEMBLY (FOH) - 26.6
BUSINESS - 8.4
KITCHEN -10.7
STORAGE - 3.7
OCCUPANCY GROUP:
NUMBER OF EXITS REQUIRED:
85 DEGREES BAKERY AND CAFE
1376 SOUTHCENTER MALL
TUKWILA, WA 98188
TUC -RC
I -A
4990 S.F.
1
1 ST FLOOR
YES
49.4 ( REFER TO OCC. DIAGRAM)
IIB
2
CONTACT INFORMATION
APPLICANT: CHIN-LEY/RECHE ASSOCIATES
1516 MELROSE AVENUE
SUITE 200
SEATTLE, WA 98122
CONTACT: SERGIO CHIN -LEY
TEL: 206.938.1501
FAX: 206.935.3449
EMAIL: sergio@chinleyreche.com
TENANT: EVERGREENS
ARCHITECT/DESIGNER: CHIN-LEY/RECHE ASSOCIATES
1516 MELROSE AVENUE
SUITE 200
SEATTLE, WA 98122
CONTACT: SERGIO CHIN -LEY
TEL: 206.938.1501
FAX: 206.935.3449
EMAIL: sergio@chinleyreche.com
BATHROOM PLUMBING FIXTURES
TOTAL OCCUPANTS: 49.4
OCCUPANTS PER GENDER: 49.4/2 = 24.7
PER TABLE 29, IBC, 2012, 1 TOILET/1 LAV REQUIRED PER GENDER
,M,X, 1 E PERMIT
REO'iRED FOR:
W"20chanical
❑ C'actrixf
8umb`ng
W -13s Poing
City f Tukwila
A_Di .G DIVIStnnr
PROJECT SITE
\/lr--lKIITV AAUP
_..., t-- c�=jproval of
I �:3 B111lding Division.
4Viii re r
in ;ude i'll Mquim a nety plan submittal
,.J't
Plan review fees.
( I7I• I I,
Permit a ...EL _ V VO
Flan revievi a0pr0vR1 is subject to errors and orn!ssions.
Approval of cor is nicfion documents does not auiholiZe
the violattion of any adopted code or ordinance. RocGipt
of approved ioid �' and condi' ns is acknowledned:
Qy:
City Of Tukwila
BUILDING DIVISION
-10.7
1
OCCUPANCY DIAGRAM
N
SCALE: 1/8"= V-0"
REVIEWED FOR
'34MPLIANCE WITH
NFPA70 - NEO
SEP 13 2016
Chin-Ley/Reche
1516 Melrose Ave., Suite 200
Seattle, Washigton 98122
206 938 1501
project title:
85 Degrees Bakery and Cafe
Southcenter
1376 Southcenter Mall
Tukwila, WA 98188
date: description:
05.02.16 progress
06.13.16 Dermit
date:
June 13, 2016
yawing if •CE V
PROJWTI 19GUE19EM I LA
SEP 31 2016
PERMIT CENTER
number
mum
REFLECTED CEILING GENERAL NOTES
_ 1. FIRE SPRINKLER SHUT DOWN, DRAIN AND FIRE WATCH REQUIRED DURING ALL
SCOPE OCCURRING AT, IN AND ABOVE CEILING AREAS. FS SHUT DOWN PROCESS TO
BE ENGAGED UNTIL ALL FIRE SPRINKLER LINES AND HEADS ARE PERMANENTLY
INSTALLED AND AFFIXED.
2. ACT SPECIFICATION TO BE TO COMMERCIAL KITCHEN -GRADE, VINYL, WHITE,
SMOOTH AND CLEANABLE.
3. FIRE ALARM TO BE WITH WHITE TRIMS.
4. FIXTURES WITH SYMBOL " ** "DENOTES EMERGENCY AND PATHWAY LIGHTING
REFLECTED CEILING PLAN KEY NOTES
O EXISTING STOREFRONT HEADER WALL
O PROTECT EXISTING DEMISING WALL, TYP.
O RESERVED
O HEADER WALL, REFER TO ELEVATIONS
O RESERVED
O RESERVED
O RESERVED
12 GA. SPLAY WIRES WITH
MINIMUM 4 TIGHT TURNS IN
1 1/2" BOTH ENDS OF
WIRE-TYP.
CROSS RUNNER
MAIN RUNNER
DISTANCE FROM BRADING —
WIRES TO RUNNERS
NOTE:
LATERAL BRACING IS NOT
REQUIRED FOR PLENUMS LESS
THAN 12" TO STRUCTURE OR
CEILINGS LESS THAN 1,000 S.F.
PROVIDED THEY ARE
SURROUNDED BY FOUR WALLS
AND BRACED TO STRUCTURE.
12 GA. VERTICAL HANGER WIRE @
4'-0" EACH WAY WITH MINIMUM 3
TIGHT TURNS WITHIN 3" BOTH
ENDS OF WIRE
SEISMIC COMPRESSION
STRUT TO BE 12'-0" O.C.
AND TO BEGIN NO
FARTHER THAN 6'-0" FROM
THE WALLS.
fttiu�
COMPRESSION STRUT SCHEDULE
EMT CONDUIT
Y2" EMT CONDUIT
UP TO 6'-0"
EMT CONDUIT
UP TO 8'-6"
1" EMT CONDUIT
UP TO 10'-0"
EMT CONDUIT
1 Va" METAL STUD (25 GA)
UP TO 6'-2"
2-1/2" METAL STUD (25 GA)
UP TO 10'-6"
NOTE: PLENUM AREAS GREATER THAN 11'-0" WILL REQUIRE ENGINEERING
CALCULATIONS.
0)DSCLAL_Al-l/2"=
CT SEISMIC BRACING
V-0"
y
SHOT IN ANCHOR
CEILING CLIP
12 GA. HANGER WIRE @ 4'0.C. ALL WIRES TO
BE THREE TIGHT TURNS AROUND ITSELF
WITHIN 3 INCHES.
1 !"CARRYING CHANNEL
@ 4'-0" O.C.
ACOUSTICAL TILE CEILING
WALL MOLDING (PERIMETER CLOSURE ANGLE)
TO BE 2" MIN. HORIZ. WIDE FLANGE. THE
CEILING GRID TO BE ATTACHED TO THE WALL
MOLDING AT TWO ADJACENT WALLS AND
SHALL HAVE A%" CLEARANCE AT
UN -ATTACHED WALLS AND BE FREE TO SLIDE.
QISETI�E:
YPACT SEISMIC BRACING
3" = 1'-0"
5,, \AAV
SWITCHING LEGEND
WOC WALL OCCUPANCY SENSOR
D DIMMER
S SINGLE POLE SWITCH
DL DAY LIGHT HARVESTING SENSOR
�A.•1•L.iM:faLiZ
'P'•'•••••••��
•y;.er •Ill
s
EXIT
S =F
MEN
/ 121 B-1 / Q B-1
11 1 D D
� l
\ ,g
\ —1
G
9 HX
B-1 n G B-1
� H
I � i
WQMEN
122
0 B -1S B-1
S GE G
12 –
E
ACT
B-3 B-3
sS
\E1 X* -*E
B-3 N N A B-3
B-3
E
** E \I I V E
W/I
11
SEATING
101
B-1
GWB
12 –0
LIGHTING FIXTURE SCHEDULE
CODE
DESCRIPTION
VENDOR OR MANUFACTURER & MODEL
FINISH
BULB
LAMPS
WATTS
1195
NOTES
:9 A
A
LINEAR LED TRACK LIGHTING
JUNO / TRAC MASTER / AVANT GARDE / ARC 13W LED / T271L27HCNBL
WHITE
LED
13W
E
107
B
PENDANT
Owner Provided
GREEN
LED
13W
78
date:
WnfiMMIB
�--i C
Strip Fixture
'Single Lamp Strip in Cove around Sales Area
WHITE
FLUORESCENT
32W
384
(Y.0
I D
RECESSED DOWNLIGHT
MAXILUME / HH6-LED / 6" ARCHITECTURAL / 900 LUMEN
WHITE
LED
12W
312
HERMIT CENTER
®E
2X4 FLUORESCENT RECESSED
LITHONIA / GENERAL PORPOSE T8 TROFFER / GT8 2X4
WHITE
FLUORESCENT
32W
2,304
GT8 2X2 for E 2X2
EDF
ILLUMINATED EXIT SIGN AND BACKUP
LITHONIA / QUANTUM THERMOPLASTIC EXIT
WHITE
FLUORESCENT
–
–
G
SCONCE
Owner Provided
Green
LED
law
26
----------------------,
B-5
TORAG
116
_LE
B-5
/
XE
B-5
TOTAL WATTS SPECIFIED = 911
1. CONTRACTOR SHALL VERIFY CATALOG PLUMBER WITH FIXTURE DESCRIPTIONS AND PROVIDE PRESCRIBED MODIFICATIONS.
2. CONTRACTOR SHALL SUBMIT CUT SHEETS AND DESCRIPTIONS FOR APPROVAL PRIOR TO PURCHASE.
EXIT F ui E= F
DL MAT
B-1 O B-1 O B-1 B-1
D D D D
O B-1
TI D
O B-1 B-1 GWB c)13-1
D D 14 –0 D
DL
O B-1 O B-1
D D
SEATING
102
I, D -1 Op -1 TI
B-1
0
BR
AD FINISH
IS
D
/ r--
-1
O B-1
B-1 O B-1
oB-1 B-1 SALES B-1
F -1-03 ]C)
B-5
E
107
D
D D
D D
B-5
U)
date:
WnfiMMIB
0
\.ddrawing
title
(Y.0
_
REFLECTED CE!6fi t -F a*
CET`: OF TUKWiLA
0
SEP 0 1 2016
LL
HERMIT CENTER
E
B-5XE
B-5
**E
KE
RSV
B-5
BREAD
10
BAKE
RSV
77
----------------------,
B-5
TORAG
116
_LE
B-5
/
XE
B-5
r-------------------
E!
OB-7
OB -7
OB -7
B-7 O B-7
B
B
YSD
i B B
i-----------------------
L — — — — — — — — — — — — — — — — — —
SERVICE
ESPRESSO
10 0
106
A**
105
A
A A A
TI
B-1
B-1
(:f) B-1 B-1 B-1
r
'
_
------------------------------------
ss
'
B-3
** E
B-5
sv B-3 B-3 B-3 B-3 B-3 B-5
C K ORATI N
DRIN PREP RSV
111
ACT
110 '
VE ME XE
1C, _�
BREAD P E
E
E
** E
10 E
-5
B-3 I I t I N AB -5 N AB
A
E E\
B-3 S KULLEF
113
:IN C
118
-11
E \I
S
B-3
MANF
**E
**
E
■
IW=
E \I I V ** E
11 119 1
E
GWB
12 –0
MAT
SALES
104
E
REVIEWED AOR
COMPLIANCE WITH
NFRA, 70 r NEC
SEP 13 2016
City of-Tulw'iIla. --
BUILDING DIVISION
SCALE: 1/4" =1'
Chin-Ley/Rwhe
1516 Melrose Ave., Suite 200
Seattle, Washigton 98122
206 938 1501
project title:
85 Degrees Bakery and Cafe
Southcenter
1376 Southcenter Mail
Tukwila, WA 98188
date: description:
05.02.16 progress
06.13.16 permit
0
BR
AD FINISH
E
B-5
E
107
RSV
E
B-5
**E
B-5
U)
date:
WnfiMMIB
0
\.ddrawing
title
(Y.0
_
REFLECTED CE!6fi t -F a*
CET`: OF TUKWiLA
0
SEP 0 1 2016
LL
HERMIT CENTER
E
B-5XE
B-5
**E
KE
RSV
B-5
BREAD
10
BAKE
RSV
77
KE
B-5
TORAG
116
_LE
B-5
XE
B-5
E
REVIEWED AOR
COMPLIANCE WITH
NFRA, 70 r NEC
SEP 13 2016
City of-Tulw'iIla. --
BUILDING DIVISION
SCALE: 1/4" =1'
Chin-Ley/Rwhe
1516 Melrose Ave., Suite 200
Seattle, Washigton 98122
206 938 1501
project title:
85 Degrees Bakery and Cafe
Southcenter
1376 Southcenter Mail
Tukwila, WA 98188
date: description:
05.02.16 progress
06.13.16 permit
0
:D
U)
date:
WnfiMMIB
0
\.ddrawing
title
(Y.0
_
REFLECTED CE!6fi t -F a*
CET`: OF TUKWiLA
0
SEP 0 1 2016
LL
HERMIT CENTER
number
o-0
SUPPLIER DESCRIPTION ELECTRICAL PLUMBING
C5 u') f- o
cn z
J (n cn
w LqU I- O = O O O Q Q I- w
'_ _12c) o c� •ac = > n- v ELECTRICAL NOTES _ z u 3:: CID m PLUMBNG NOTES �-
12.
1
1
0lmmml�i
PARE NUMBER
MJMM=lel
PARE
SPARE
111111MI'SPARE NUMBER
j�1=1111IMM1111=111SPARE
NUMBER
1 .. I===ISI
SPARE NUMBER
NUMBER
IG
itI
1. THE ELECTRICAL CONTRACTOR SHALL SUPPLY AND INSTALL SEAL-TITE FLEX CONDUIT TO ALL FOOD SERVICE
EQUIPMENT IN DAMP AREAS, I.E., SCULLERY, BAR ROOF, ETC. FLEX CONNECTIONS AT ALL FANS ON THE
ROOF SHALL BE OF EXTRA LENGTH TO ALLOW FULL FAN REMOVAL FOR THE EASE OF CLEANING.
2. THE ELECTRICAL CONTRACTOR SHALL PROVIDE FUSED DISCONNECTS FOR EQUIPMENT HOOK-UPS AS
REQUIRED BY CODE AND LABELING.
3. THE ELECTRICAL CONTRACTOR SHALL PROVIDE DISCONNECTS IN A CONVENIENT ACCESSIBLE LOCATION AT
AT THE POWER BOX FOR EACH ICE MACHINE HEAD.
4. THE ELECTRICAL CONTRACTOR SHALL PROVIDE AND INSTALL AN INTERCONNECT CIRCUIT BETWEEN THE ICE
MACHINE HEADS (ITEM 39) AND THE REMOTE CONDENSING UNITS ON THE ROOF AS REQUIRED BY THE
MANUFACTURER.
5. THE ELECTRICAL CONTRACTOR SHALL PROVIDE AND INSTALL A VAPOR -PROOF SWITCH AT EACH
BLOWER COIL IN THE WALK-IN COOLER (ITEM 32.1, 32.3, AND 33.1).
8. THE ELECTRICAL CONTRACTOR SHALL PROVIDE AND INSTALL A 48" MINIMUM CORD AND PLUG
FOR EACH PIECE OF EQUIPMENT SO NOTED. USE 90i ELBOW OUT OF UNIT.
10. THE ELECTRICAL CONTRACTOR SHALL PROVIDE FOR HOOK-UP OF A THERMOSTAT, SOLENOID, BLOWER
COIL AND COMPRESSOR FOR EACH REFRIGERATED UNIT. MAGNETIC STARTERS AND/OR THERMAL
PROTECTORS SHALL BE INCLUDED AS NECESSARY.
11. THE ELECTRICAL CONTRACTOR SHALL PROVIDE 1" CONDUIT AND JUNCTION BOXES AT EACH CASH
REGISTER TERMINAL SO AS TO INTERCONNECT ALL UNITS TO EACH OTHER AND TO THE CENTRAL
PROCESSING TERMINAL. CONSULT WITH THE OWNER'S REPRESENTATIVE FOR EXACT LOCATIONS OF ALL
TIE-IN UNITS.
13. THE PLUMBING CONTRACTOR SHALL PROVIDE AND INSTALL ALL DRAIN LINES FROM WALK-IN
BLOWER COILS TO FLOOR SINKS. HEAT TAPE SHALL BE PROVIDED AND WRAPPED AT ALL
DRAIN LINES SUBJECT TO THE POSSIBILITY OF FREEZING, SUPPLIED AND INSTALLED BY ELECTRICAL
CONTRACTOR.
14. ALL DRAIN LINES FROM EQUIPMENT REQUIRING CONDENSATION REMOVAL SHALL BE DONE IN
COPPER.
15. IT SHALL BE THE RESPONSIBILITY OF "OTHERS" TO INTERCONNECT THE HOOD FIRE PROTECTION
SYSTEMS TO THE BUILDING FIRE DETECTION UNITS AS REQUIRED.
19. THE ELECTRICAL CONTRACTOR SHALL SUPPLY AND INSTALL TO EACH PIECE OF ROOF -TOP EQUIPMENT
(FANS, MOTORS, COMPRESSORS, CONDENSERS, ETC.) A SEPARATE WEATHER -PROTECTED DISCONNECT
SWITCH.
22. IT SHALL BE THE RESPONSIBILITY OF THE PLUMBING AND ELECTRICAL CONTRACTORS TO MAKE
ALL REQUIRED WATER, GAS, DRAIN AND ELECTRICAL FINAL CONNECTIONS FOR ALL MAKE-UP AIR
SYSTEM UNITS.
23. IT SHALL BE THE RESPONSIBILITY OF THE ELECTRICAL CONTRACTOR TO INSTALL ALL OWNER
SUPPLIED COMPUTER/COMMUNICATIONS CABLES AS PER OWNERS DIRECTION.
24. IT SHALL BE THE RESPONSIBILITY OF PLUMBING CONTRACTOR TO COMPLY WITH ALL LOCAL CODES
CONCERNING GAS VALVE REGULATOR VENTING.
25. ELECTRICAL CONTRACTOR SHALL PROVIDE A INDIVIDUAL DISCONNECT BOX FOR EACH PIECE OF
ROOF TOP ELECTRICALLY POWERED EQUIPMENT.
26. THE GENERAL CONTRACTOR SHALL PHOTOGRAPH ALL WALLS CONTAINING BACKING PRIOR TO
SHEETROCK/FRP INSTALLATION.
27. THE PLUMBING CONTRACTOR SHALL PROVIDE CLEANOUTS AT 1ST ELBOW ON EACH WALK-IN
BLOWER COIL DRAIN.
29. THE PLUMBING CONTRACTOR SHALL SUPPLY AND INSTALL WATER LINE BACK CHECK VALVES AS
REQUIRED PER CODE.
30. THE ELECTRICAL CONTRACTOR SHALL PROVIDE INTERCONNECT SWITCHING BETWEEN THE KITCHEN
EXHAUST HOOD EXHAUST FANS AND THE KITCHEN MAKE-UP AIR SYSTEMS AS REQUIRED PER
LOCAL CODE AND AUTHORITIES.
31. COMMUNICATIONS CABLES ARE SUPPLIED BY OWNER AND INSTALLED BY ELECTRICAL CONTACTOR.
34. PLUMBING CONTRACTOR TO INSTALL DISPOSER PER MANUFACTURER'S SPEC. SHEET.
35. PRESSURE REGULATORS FOR GAS COOKING EQUIPMENT SUPPLIED BY B/E AND INSTALLED PER
CODE AND MANUFACTURER'S SPECIFICATIONS BY PLUMBING CONTRACTOR.
36. ELECTRICAL CONTRACTOR SHALL PROVIDE INTER CONNECT FOR FREEZER COIL & TIMECLOCK
CIRCUIT DEFROST SYSTEM.
EVI Wc: .
COMPLIANCE WiT'H
gNFP 7O � IIEC
SEP 1 3 2016
city OfTul-nulla
SUILDiNlG DIVISION
T'i E�E;'ti1E:J
,;pfy OF -TUKWILA
Seg' 0 12016
?ERMIT CENTER
N
STORAGE
WH
C-1
CLEANING
STORAGE
Q� __ ___ W
C-33,35,37 x
------ -- — �-
9 +24' G.1
+120' B-��__2__
C- 11,1,3,15 8 B-34
DROP Mj
�a1
�. IR
S/1 �B `
97 B-32
+ 8' 98
13-417
+4s' 98
ZE
X
B-21
64 r�
C-7
Show
Window
B-21
50
. moi/ •
�s �JC� • • c
- - - g +120"
115/1
_D1155
Show
Window
B-25 C48.
B-25 r--\
B-23 4 +24'
B-23 11.
115/1155 ! 1
B-30 +24' 13e+48"' `. ;�. ; B-30 U� B-41 11 +2427 B-30' , n \ h B-2,4 28 +48'1648
\/7 +24' 115/1
V V B-30 155 C-23,25 34 +`�� C-15,1 63
DROP
91
(513-32 B-38,40,42
B 2
DROP CORD
115/1
15A 32 +120
B-24,26,28
r
32
% B-18,20,22
1117 a ._
Television
+120,, B-23
B-23 115/1 j
15A
B-23
+120"
115/1
j+12' + 2'
C-7 B-27 B-27 +124 B-27
Show
Window 115/11
C-7 155
B-29/; .,
R.R . B-27
B-29
B-27
B-29 51� B-27
70C
B-27 B-27 B-27
I r
M r
I 115/1 L_T�
i �---- 155 �
B-41
L I 1
1 ---- q \37,39
L_ -_j L --J
+24(27 B-31
�d �� i
i u v i
iTiil +24ii " 74
• �/
--- 1115
/1 - - �.� - - -� *�
B-31
------------------
B-41 — _ -- — — -33,35 8 +120 `� \ \
I
B-31 �9 —+24'
33.133
B-12,14,16
I
33
B- +120'
31 54
ROOF
SEE ARCHITECT'S DRAWINGS
8 32.2 32.4 33.3 39.1
ELECTRICAL NOTES
1. THE CONTRACTOR SHALL PROVIDE AND INSTALL STAINLESS STEEL OUTLET AND RECEPTACLE
COVERS IN SERVICE AREAS.
3. THE ELECTRICAL CONTRACTOR SHALL CONNECT ALL REMOTE COMPRESSORS AND PROVIDE
DISCONNECTS, MAGNETIC STARTERS, AND THERMAL OVERLOAD PROTECTION AS REQUIRED.
4. THE ELECTRICAL CONTRACTOR SHALL PROVIDE AND INSTALL HEAT TAPE ON DRAIN LINES IN
DANGER OF FREEZING.
5. THE ELECTRICAL CONNECTIONS, SPECIFICATIONS AND DIMENSIONS SHOWN ON THESE PLANS
ARE FOR FOOD SERVICE EQUIPMENT ONLY. SEE THE ARCHITECTS PLAN SET FOR ALL OTHER
ELECTRICAL REQUIREMENTS FOR THIS PROJECT.
6. ALL ELECTRICAL ROUGH -IN WORK AND ALL FINAL CONNECTIONS FOR ALL ITEMS SHOWN AND
SPECIFIED ON THESE PLANS BY CMA SHALL BE PERFORMED BY THE ELECTRICAL
CONTRACTOR.
7. UNLESS OTHERWISE SPECIFIED IN THESE PLANS OR OTHER WRITTEN CONTRACTS, IT SHALL BE
THE RESPONSIBILITY OF THE ELECTRICAL CONTRACTOR TO PROVIDE ALL ELECTRICAL -TYPE
MATERIALS INCLUDING WIRING, SWITCHES, DISCONNECTS, FLEX, CONDUIT, CONTACTORS,
TRANSFORMERS, THERMAL OVERLOAD PROTECTORS, MAGNETIC STARTERS, ELECTRICAL
PANELS, CORDS, PLUGS, COVERS, ETC.
9. ALL DIMENSIONS SHOWN ARE FROM GRID LINES, FINISHED WALLS OR FINISHED FLOORS TO
CENTER LINE OF ELECTRICAL OUTLET BOXES. HEIGHTS ARE NOT TO BE TAKEN FROM CURBS OR
PLATFORMS.
10. THE SYMBOLS SHOWN ON THIS PLAN ARE FOR INDICATION OF ROUGH -IN LOCATION AND TYPE
OF CONNECTION ONLY. THE ELECTRICAL CONTRACTOR SHALL PROVIDE CIRCUITS AND CONDUIT
RUNS AS PER GOOD PRACTICE AND CODE.
11. IT SHALL BE THE RESPONSIBILITY OF THE ELECTRICAL CONTRACTOR TO PROVIDE INTERCONNECT
SWITCHING BETWEEN THE KITCHEN EXHAUST HOOD EXHAUST FANS AND THE KITCHEN MAKE UP AIR
SYSTEMS AS REQUIRED PER LOCAL CODE AND AUTHORITIES.
12. THE ELECTRICAL CONTRACTOR SHALL PROVIDE FUSED DISCONNECTS FOR EQUIPMENT
HOOK-UPS AS REQUIRED BY CODE AND LABELING.
13. ALL GFCI RECEPTACLES SHALL BE LOCATED IN AN ASSESSABLE LOCATION FOR STATIONARY EQUIPMENT.
ELECTRICAL LEGEND.
C=
115 VOLT DUPLEX OUTLET
I
115 VOLT DCO, DEDICATED/ISOLATED
208V SPECIALTY OUTLET
®
JUNCTION BOX
COMMUNICATIONS CABLE VERIFY SPEC'SAQINTWTHD
ON/OFF SWITCH
VERIFY EQUIPMENT REQUIREMENTS WITH FINAL EQUIPMENT SELECTIONS
GFCI RECEPTACLES SHALL BE PASS & SEYMOUR N0. 2095-W
RTU- 30 AMP DISC 480V
NEMA 3R
RT EXHAUST FAN - 30
AMP DISC 480V NEMA
3R
EVIEWED FOH
COMPLIANCE VOTH
NIM _70 - MEG
SEP 1 3 2016
City OfTufaviia.
BUILDING DIVISION
LO
N