Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Permit EL16-0815 - NW HYDRAULICS - SERVICE, PANELS, TRANSFORMER ETC
NW HYDRAULICS 12787 GATEWAY DR EL16-0815 City of Tukwila • ' "' Department of Community Development • 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Inspection Request Line: 206-438-9350 Web site: http://www.TukwilaWA.Rov ELECTRICAL PERMIT Parcel No: 2716000060 Permit Number: EL16-0815 Address: 12787 GATEWAY DR Issue Date: 9/15/2016 WA Cities Electrical Code: 2014 Permit Expires On: 3/14/2017 Project Name: NW HYDRAULICS 2014 Owner: 2015 WA State Energy Code: Name: EPROPERTY TAX INC DEPT#207 2015 Address: PO BOX 4900, SCOTTSDALE, WA, 85261 Contact Person: � Name: MATT SNYDER Phone: (206) 633-2811 Address: 12828 NORTHUP WAY, SUITE 205, BELLEVUE, WA, 98005 Contractor: Name: TITAN ELECTRIC INC Phone: (206) 633-2811 Address: 12828 NORTHUP WAY, SUITE 205, BELLEVUE, WA, 98005 License No: TITANE1963OB Expiration Date: 9/2/2018 Lender: Name: Address: DESCRIPTION OF WORK: INSTALL NEW 200 AMP SERVICE, TWO 200 AMP PANELS, ONE 75KVA TRANSFORMER, (65) RECEPTACLES, (20) FIXTURES. Valuation of single family: $0.00 Fees Collected: $3,201.44 Valuation of mf/comm: $165,000.00 Type of Work: REMODEL Electrical Service Provided by: SEATTLE CITY LIGHT Water District: TUKWILA Sewer District: TUKWILA Current Codes adopted by the City of Tukwila: International Building Code Edition: 2015 National Electrical Code: 2014 International Residential Code Edition: 2015 WA Cities Electrical Code: 2014 International Mechanical Code Edition: 2015 WAC 296-466: 2014 Uniform Plumbing Code Edition: 2015 WA State Energy Code: 2015 International Fuel Gas Code: 2015 Permit Center Authorized Signature: � Date: a- �s- I hearby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this development permit and agree to the conditions attached to this permit. Signa Print Date: �( This permit shall become null and void if the work is not commenced within 180 days for the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. PERMIT CONDITIONS: 1: 'ELECTRICAL PERMIT CONDITIONS' 2: A copy of the electrical work permit shall be posted or otherwise made readily accessible to the Electrical Inspector at each work site. 3: Approved plans shall be maintained at the construction site and shall be readily available to the Electrical Inspector. 4: All electrical work shall be in accordance with NFPA 70 - NEC, and requirements for electrical installations, Chapter 296-46B WAC. 5: When any portion of the electrical installation is to be hidden from view by permanent placement of parts of the building, such equipment shall not be concealed until it has been inspected and approved by the Electrical Inspector. 6: The issuance of an electrical work permit shall not be construed to be a permit for, or an approval of, any violation of the provisions of the electrical code or other ordinances of the jurisdiction. Permits or related documentation that presumes to grant this authority are therefore not valid. 7: Any change in the scope of work described by the electrical work permit shall require additional work permits. Where approved plans have been issued, revisions to the plans and additional review may be required. PERMIT INSPECTIONS REQUIRED Permit Inspection Line: (206) 438-9350 2100 ELECTRICAL FINAL 7003 ROUGH -IN ELECTRICAL 7002 SERVICE 7001 UNDERGROUND/SLAB CITY OF TUKW, Community Development Department Permit Center et! 6300 Southcenter Blvd., Suite 100Tukwila, WA 98188 http://www.Tukwi]aWA.gov SITE LOCATION Electrical Permit No. Project No. Date Application Accepted: Date Application Expires: use ELECTRICAL PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. "Please Print" King Co Assessor's Tax No.: Site Address: 12787 Gateway Drive. Tukwila WA 98168 Suite Number: Bldg 6 Floor: 1 Tenant Name: NW Hydraulics New Tenant: ® .....Yes ❑ ..No PROPERTY OWNER Name: Kidder Mathews Address: 12886 Interurban Ave S City: Seattle State: WA Zip: 98168 CONTACT PERSON — person receiving all project communication Name: Matt Snyder Address: 12828 Northup Way, Suite 205 City: Bellevue State: WA Zip: 98005 Phone: (206) 633-2811 Fax: (206) 374-2128 Email: matts@titanelectric.net ELECTRICAL CONTRACTOR INFORMATION Company Name: Titan Electric Address: 12828 Northup Way, Suite 205 City: Bellevue State: WA Zip: 98005 Phone: (206) 633-2811 Fax: (206) 374-2128 Contr Reg No.: TitanE19630B Exp Date: 09/02/2018 Tukwila Business License No.; BUS -0992893 Valuation of Project (contractor's bid price): $ 165,000 Scope of Work (please provide detailed information): Install new 200 amp service, two 200 amp panels, one 75kva transformer, (65) receptacles, (20) fixtures. Will service be altered? m Yes ❑ No Adding more than 50 amps? Yes ❑ No Type of Use: Me of work: ❑ New ❑ Addition ❑ Service Change ® Remodel ® Tenant Improvement ❑ Low Voltage ❑ Generator ❑ Fire Alarm ❑ Telecommunication ❑ Temporary Service Property Served by: P Puget Sound Energy ❑ Seattle City Light H:Vtppliwtions\Forms-Applications On Linc\2014 ApplicationsTlccttical Permit Application Rcvised 1.1.14.docx Rcvised: January 2014 bh Page 1 of 2 RESIDENTIAL NEW RESIDENTIAL SERVICE ❑ New single family dwellings ................................... $152.85 (including an attached garage) ❑ Garages, pools, spas and outbuildings ........................$81.90 ea ❑ Low voltage systems (alarm, furnace thermostat) ................................ $59.85 ea RESIDENTIAL REMODEL AND SERVICE CHANGES ❑ Service change or alteration ...................................... $81.90 ❑ (no added/altered circuits) $80.90 ❑ Service change with added/altered circuits ................. $81.90 number of added circuits ....................... $11.55 ea ❑ Circuits added/altered without service change ........... $54.60 (up to 5 circuits) $10.80 ea ❑ Circuits added/altered without service change ........... $54.60 (6 or more circuits) ............................................... $7.65 ea ❑ Meter/mast repair ....................................................... $68.25 ❑ Low voltage systems ................................................. $59.85 (alarm, furnace thermostat) PERMIT APPLICATION NOTES - MULTI -FAMILY AND COMMERCIAL Fees are based on the valuation of the electrical contract. MISCELLANEOUS FEES ❑ Temporary service (residential) ................................. $65.00 ❑ Temporary service (generator) ................................... $80.90 ❑ Manufactured/mobile home service ........................... $86.25 (excluding garage or outbuilding) ❑ Carnivals.................................................................... $80.60 Number of concessions ......................... $10.80 ea Each ride and generator truck ............... $10.80 ea ***EFFECTIVE JANUARY 1, 2014 EACH PERMIT WILL BE ASSESSED A 5% TECHNOLOGY FEE*** Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The Building Official may grant one extension of time for an additional period not to exceed 90 days. The extension shall be requested in writing and justifiable cause demonstrated. I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER OR ELECTRICAL CONTRACTOR: Signature: CI Date: 09/07/2016 Print Name: Jon Osborne Day Telephone: (206) 633-2811 Mailing Address: 12828 Northup Way, Suite 205 Bellevue WA 98005 City State Zip HAApplicationsTouns-ApplicationsOn Line\2014 Applications\Electrical Permit Application Revised 1-1-14.docx Revised: January 2014 bh Page 2 of 2 DESCRIPTIONS PermitTRAK ACCOUNT QUANTITY PAID $2,585.78 EL16-0815 Address: 12787 GATEWAY DR Apn: 2716000060 $2,585.78 ELECTRICAL $2,462.65 PERMIT FEE MULTI-FAM/COMM R000.322.101.00.00 0.00 $2,462.65 TECHNOLOGY FEE $123.13 TECHNOLOGY FEE TOTAL FEES PAID BY RECEIPT: .. 425 R000.322.900.04.00 0.00 $123.13 $2,585.78 Date Paid: Thursday, September 15, 2016 Paid By: TITAN ELECTRIC INC Pay Method: CHECK 21829 Printed: Thursday, September 15, 2016 11:51 AM 1 of 1 SYSTEMS DESCRIPTIONS PermitTRAK • 1 $683.91 EL16-0813 Address: 12787 GATEWAY DR Apn: 2716000060 $68.25 ELECTRICAL $65.00 PERMIT FEE MULTI-FAM/COMM R000.322.101.00.00 0.00 $65.00 TECHNOLOGY FEE $3.25 TECHNOLOGY FEE R000.322.900.04.00 0.00 $3.25 EL16-0815 Address: 12787 GATEWAY DR Apn: 2716000060 $615.66 ELECTRICAL $615.66 PLAN CHECK FEE TOTAL FEES PAID BY RECEIPT: .. R000.345.832.00.00 0.00 $615.66 $683.91 Date Paid: Wednesday, September 07, 2016 Paid By: TITAN ELECTRIC INC Pay Method: CHECK 21775 Printed: Wednesday, September 07, 2016 4:37 1 of 1 �LrL 1 SYSTEMS PM INSPECTION RECORD Retain a copy with permit INSPECTION N0. PERMIT NO. CITY OF TUKWILA BUILDING 6300 Southcenter Blvd., #100, Tukwila. WA 98188 Permit Ins Fection Request Line (206) 438-9350 DIVISION (206) 431-367 G� Project: 1 / Type of Inspection: Address: 12,11 Date Called: Special Instruction's: Date Wanted: a. It p.m. Requester: Phone No: REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. INSPECTION RECORD Retain a copy with permit "C' INSP TION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 4 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Ins Tection Request line (206) 438-9350 Project: Q 41, Type of Inspection: Address: Date Called: Special Instru do s: bate—wanted: a.m Requester: Phone No: 11 Approved per applicable codes. E Corrections required prior to approval. inspector: /�1 /r�.,, /i� (uate: t t /t 7 //& REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Calt to schedule reinspection. INSPECTION RECORD 164t Retain a copy with permit air INSP CTION N0. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Ins ection Request Line (206) 438-9350 Project:4ff 14) �l�1 �ld Type sop�ection: 4L- Address:/,�—Z 7 �wtAW Date Called: Special Instructio : Date wanted:P a l p.m Requester: Phone No: Approved per applicable codes. IV Corrections required prior to approval. l nspector: REINSPECTION'FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd.. Suite 100. Calt to schedule reinspection. INSPECTION RECORD i-� / A � �13 ----I Retain a copy with permit C INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 5outhcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Project: W IJ CAJ Type of Inspection: r Address: �. Date Called: Special Instructions: Date Wanted: / O L ` a.m p.m. Requester: Phone No: ElApproved per applicable codes. Corrections required prior to approval. I - L,t)Wf�' -1 CL1 n VT IInspector: c�7,11(-u I a (Date: t IIW,W I REINSPECTION 9EE REQUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. INSPECTION RECORD Retain a copy with permit t 1�1'i INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Pr oj c � � Type of I �cton�* , 3� Address: dew Date Called: 1 Special Instructions: Date Wanted: a Requester: PhonNo: -13�a FlApproved per applicable codes. 11 Corrections required prior to approval. u paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. INSPECTION RECORD t74,6Retain a copy with permit ,0 �yrll INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Reauest Line (206) 438-9350 ❑ Approved per applicable codes. L__.J Corrections required prior to approval. COMMENTS: U -1A -.r- 4e L.( Inspector Date: F] REINSPECTION FEE REQUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. PERMIT COOR® COPY, PLAN REVIEW/ROUTING SLIP PERMIT NUMBER: EL16-0815 PROJECT NAME: NW HYDRAULICS SITE ADDRESS: 12828 GATEWAY DR X Original Plan Submittal Response to Correction Letter #, DATE: 09/07/16 1 Revision # before Permit Issued Revision # after Permit Issued DEPARTMENTS: A Awc q. 1&4 Building Division G Fire Prevention ❑ Planning Division ❑ Public Works ❑ Structural ❑ Permit Coordinator ❑ PRELIMINARY REVIEW: DATE: 09/08/16 Not Applicable ❑ Structural Review Required ❑ (no approval/review required) REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: DUE DATE: 10/06/16 Approved ❑ Approved with Conditions Corrections Required ❑ Denied ❑ (corrections entered in Reviews) (ie: Zoning Issues) Notation: REVIEWER'S INITIALS: 197:16:1 Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: 12/18/2013 TITAN ELECTRIC INC Horne Espanol Contact Safety & Health Washington State Department of Cj Labor & Industries TITAN ELECTRIC INC Owner or tradesperson Principals BURKE, PATRICK D, PRESIDENT CROOK, TRAVIS J, VICE PRESIDENT FLING, LAWRENCE H, SECRETARY FLING, LAWRENCE H, AGENT Doing business as TITAN ELECTRIC INC Page 1 of 4 Search L&I�� A -L Index Help MyL&I Claims & Insurance Workplace Rights Trades & Licensing 12828 Northup Way Ste 205 BELLEVUE, WA 98005 206-633-2811 KING County WA UBI No. Business type 602 250 925 Corporation Governing persons LAWRENCE M FUNG PATRICK DUNIVON BURKE; TRAVIS JAY CROOK; License Verify the contractor's active registration / license / certification (depending on trade) and any past violations. Electrical Contractor Active. .............................................................. Meets current requirements. License specialties GENERAL License no. TITANE19630B Effective — expiration 09/02/2004— 09/02/2018 Designated administrator Active. CROOK, TRAVIS Meets current requirements. License type License no. Electrical Administrator CROOKT'011PB Bond ........._.._. Lexon Ins Co $4,000.00 Bond account no. 9808431 Received by L&I Effective date 08/08/2011 08/03/2011 Expiration date Until Canceled Bond history Savings No savings accounts during the previous 6 year period. https:Hsecure.Ini.wa.gov/verify/Detail.aspx?UBI=602250925&LIC=TITANEI963OB&SAW= Help us improve 9/15/2016 LIGHTING FIXTURE SCHEDULE Project Title: NW HYDRAULICS Date 8/25/2016 Compliance forms do not WATTS/ TYPE DESCRIPTION LAMP FIXT Company Address: 19515 N. CREEK PKWAY SUITE 302 BOTHELL, WA INTERIOR M Ail C405.2.1- C405.2,8 Controls (' C405.2 Exception 5 Luminaire Level Applicant Name: STEPHANIE ENLOW F1 EXISTING OR RELOCATED BUILDING STANDARD FLUORESCENT 2x4 2-F32T8 62 Project Description TROFFER. To comply vith C406.4, no less than 90% of the total installed interior lighting power shall comply 111th Include PROD -SUM form (included in envelope forms wrkbook) Wth lighting complliance forms. F2 RECESSED 2x2 LED TROFFER LED 18 F3 NOT USED. Refer to Section C502.2.6 for addition., requirements. Lighting systems in addition are combined with existing i building lighting systems to demonstrate compliance 13 F4 RECESSED COMPACT FLUORESCENT DOWNLIGHT 2-CFQ13 29 F5 DECORATIVE LED PENDANT LED 10 F6 PENDANT MOUNTED FLUORESCENT HIGH BAY TO MATCH EXISTING. 4-F32T8 124 F7 FLUORESCENT STRIP FIXTURE. 2-F32T8 62 X1 EXIT SIGN UNIVERSAL MOUNT WITH GREEN STENCIL FACE AND LED 5 of the retrofit project If project includes combination of spaces tlhere less than 50% of the existing fixtures are replaced INTEGRAL EMERGENCY BATTERY BACK UP. CRP CONTROL RELAY PANEL — — Lamp and/or ballast replacement only Q 1 13 -existing total wattage not increased 1 1 B1 EMERGENCY BATTERY PACK WiTH TWO ROTATABLE HIGH PERFORMANCE 2-3W LED 6 50% threshold applies to numberof luminaires for interiorspaces and parking garages, and total PATHWAY HEADS. 268 LUMENS PER HEAD. installed iiottage for exterior luminaires. requirements. 2015 Washington State Energy including R2, R3, R4 over 3 stories Project Info Project Title: NW HYDRAULICS Date 8/25/2016 Compliance forms do not Applicant Information. Provide contact information for individual uho can respond to inquiries about compliance form information provided. For Building Department Use - Company Name: CASE ENGINEERING require a password to Allowance Method Company Address: 19515 N. CREEK PKWAY SUITE 302 BOTHELL, WA use. Instructional and calculatingcelis are vrfte- protected. M Ail C405.2.1- C405.2,8 Controls (' C405.2 Exception 5 Luminaire Level Applicant Name: STEPHANIE ENLOW Applicant Phone: 425402-9400 EXT 16 Applicant Email: STEPHANiEr@CASEENG.COM r] Additional Efficiency Package Option 744 Project Description EI New Building Q Addition EaAlteration 0 Plans Included To comply vith C406.4, no less than 90% of the total installed interior lighting power shall comply 111th Include PROD -SUM form (included in envelope forms wrkbook) Wth lighting complliance forms. Building Additions Compliance Method I Interior lighting Exterior fighting Lighting Lighting systems in addition area comply with all applicable 1 fl provisions as a stand alone new construction project 13 Refer to Section C502.2.6 for addition., requirements. Lighting systems in addition are combined with existing i building lighting systems to demonstrate compliance 13 D Addition is combined with existing: IQ DUPLE( RECEPTACLE Description Forinterfor lighting projects, include new + existing interior lighting fixture voltage in Proposed (� DOUBL= DUPLEX RECEPTACLE Lighting Wattage table in LTG -INT -BLD orLTG-INT SPACE form, C CONDUIT Forexterior fighting projects, include new + existing exterior lightingfixture tlattage in Proposed ® RECESSED LINEAR FIXTURE Tradable and Proposed Non -Tradable Lighting Wattage tables in LTG -EXT form. Interior and Exterior Lighting Power I Interior lighting i Parking garage Exterior lighting o 50 /o or more of existing are replaced 1 13 1 ❑ Q Li htin Alterations ' g g Select all Lighting Polder and Lighting Control elements that apply to the scope ; I Less than 50% of existing are replaced!� � Q 13 of the retrofit project If project includes combination of spaces tlhere less than 50% of the existing fixtures are replaced RECESSED WALLWASHER CRP CONTROL RELAY PANEL — — Lamp and/or ballast replacement only Q 1 13 -existing total wattage not increased 1 1 13 in some spaces, and 50'A ormore of the fixtures are replaced in others, then provide separate lighting hover compliance forms for the 14to retrofit conditions. Spaces undergoing the same type of retrofit may be combined into one fighting potter compliance form. 50% or more replaced - Total lighting potter of new+ existing -to -remain fixtures shallcomply ttith total LPA per Sections C405.4.2 and C405.5.2. include new + existing -to -remain fixtures in Proposed Lighting Wattage table in LTG -INT -BLD, LTG 4NT--SPACE or LTG -EXT form. Less than 50% replaced - Total fighting pomr of new + existing -to -remain fixtures shall not exceed the total lighting pover prior to alteration. include new + existing -to -remain fixtures in the Proposed Lighting Wattage table in LTG -INT -BLD, LTG -INT -SPACE or LTG -EXT form. ©@) RECESSED EMERGENCY EGRESS DOWNUGHT 50% threshold applies to numberof luminaires for interiorspaces and parking garages, and total Refer to Section C503.6 for additional installed iiottage for exterior luminaires. requirements. Lighting Controls i interior lighting I Parking garage Exterior lighting All alteration lighting controls shall be commissioned perC408.3. New wiring installed to serve added ( I fixtures and/or fixtures relocated to i © 13 DISP DISPOSER new circuit(s) ® EM DIRECTIONAL EXIT SIGN (ARROWS INDICATE ONE OR TWO SIDES i New ormoved lighting pane! Ei EI I � Q DF DRINKING FOUNTAIN Interior space is reconfigured - luminaires unchanged or relocated i 1 New wiring orcircuit - For interiorlighting, provide required manual controls perC405.2.3, DOUBLE DUPLEX GFCI RECEPTACLE MOUNTED +4"O.C. ABOVE occupancysensorcontrols per C405.2.1, daylight responsive controls per C405.2.4 and application r3No changes are being made to the interior or exterior lighting systems and existing space uses and configuration are not changed. specific lighting controls per C405.2.5. For exterior lighting, provide required controls per C405.2.Z New ormoved panel - Provide all applicable lighting controls as noted for New tiring and automatic lime witch controls per C405.2.2. Reconfigured interior space - Provide all required lighting controls that apply to a new Interior space. Application specific lighting control provisions per 0405.2.5 do not apply to reconfigured Change of Space Use Q Existing interior lighting systems in areas under -going a change in space use are upgraded to comply with LPAs for the new space types per Tables C405.4.2(1) or C405.4.2(2). Identify interiorspaces requiring LPD upgrade to the current Code in Proposed Lighting Wattage WP Fable in LTG -INT -BLD or LTG-INT=SPACE form. 2015 Forms for over 3 stories and all R1 Revised July Project Title: NW HYDRAULICS Date 8/25/2016 Interior Lighting System Q C Addition - O Addition standalone +existinCJ ® Spaces where< 50%of O Spares where.�50%of C luminaires are replaced lurrdnaires are replaced Description LPA Calculation Type Interior Lighting Power 13 Building Area Method ® Spare -by -space Method Allowance Method Selectmethod used in project Interior Lighting Controls M Ail C405.2.1- C405.2,8 Controls (' C405.2 Exception 5 Luminaire Level 40 Lighting Control (LH C) 1488 1 r] Additional Efficiency Package Option 744 C406.4 Enhanced digital fighting controls AFF ABOVE FINISHED FLOOR To comply vith C406.4, no less than 90% of the total installed interior lighting power shall comply 111th required controls per C406.4. Dwelling Unit Interior Permanently installedinteriorlighting fixtures in dwiling units complyxith: Lighting 0 C405.2thru C405.5 Commercial Lighting Controls and LPA 9976 0 C406.3 High Efficacy Lighting 0 Exterior Lighting System IQ DUPLE( RECEPTACLE Description BKR BREAKER 2015Washington State Energy Code Compliance Forms for commercial Buildings including R2. R3. R4 over 3 stories and all R1 ReHsed July 2016 Project Title: NW HYDRAULICS Date 8/25/2016 Calcination Area NOTE Q C Addition - O Addition standalone +existinCJ ® Spaces where< 50%of O Spares where.�50%of C luminaires are replaced lurrdnaires are replaced For Building Department Use .- _._.._ � LPA Calculation Type 0 Standard 0 Additional Efi'idencyPackage Option 0 C406.3 Reduced Interior Lighting To comply with C406.3, the Proposed LPD shall be 25% lower than the Target LPA. Refer to 0406.3 faraddilional requirements. Maximum Allowed Lighting Wattage"O7E' NOTE: LIGHTING FIXTURE SYMBOLS SHOW LENGTH, Location (plan #, Height' Gross Interior room 9) Space Type 2 Area in fe Allowed Watts Allowed Watts per ft (v.mttsift2 x area) F5 -DECORATIVE LED PENDANT 4 10 40 F6 -PENDANT MTD FLUOR HiGH BAY -4 LAMP 12 124 1488 1 F7 -CHAIN MTD FLUOR STRIP -2 LAMP 12 62 744 SCHEDULE FOR LAMP TYPE & OTHER FIXTURE SPECIFICS. AFF ABOVE FINISHED FLOOR AHJ AUTHORITY HAVING JURISDICTION POWER RECEPTACLES &OUTLETS Total Area Retail Display Allowance from LTG -INT -DISPLAY Enter Total F.:dstmg Lighting Watts (prior to Alteration) 15046 I Lobby Art/Exhibit Display Allowance from LTG -INT -DISPLAY NOTc 8 L� Proposed Lighting Wattage"' Allovded Watts] 15046 I Location (plan #,- - Number of Wattst 6 5, room #) Fixture Description NOTE 4, Fixtures FiNOTE 7 xture I Watts j Proposed 1 F1 -EXIST OR RELOCATED 2x4 FLUOR TROFFER -2 119 62 7378 F2 -RECESSED 2X2 LED TROFFER 2 18 36 F3 -NOT USED NOTE: LIGHTING FIXTURE SYMBOLS SHOW LENGTH, 174 -RECESSED CFL DNLT-1 LAMP 10 29 290 F5 -DECORATIVE LED PENDANT 4 10 40 F6 -PENDANT MTD FLUOR HiGH BAY -4 LAMP 12 124 1488 1 F7 -CHAIN MTD FLUOR STRIP -2 LAMP 12 62 744 SCHEDULE FOR LAMP TYPE & OTHER FIXTURE SPECIFICS. AFF ABOVE FINISHED FLOOR AHJ AUTHORITY HAVING JURISDICTION POWER RECEPTACLES &OUTLETS Proposed Retail Display Lighting from LTG-INT-DiSPLAY Total Proposed Wattsmaynotexceed TotaiAllowedWatts for Interior Lighting Total Proposed Watts 9976 Interior Lighting Power Allowance COMPLIES Note 1- List all unique space types perTable C405.4.2(2) thatoccurin the project scope. Selectspace type categoyper iron drop down menu. Note 2 - indicate coffing height foratriums and spaces utilizing the ceiling height adjustment per Table C40a 4.2(2), Footnotes d thru f. Note 3 - List all proposed lighting fixtures including exempt lighting equipment and existing -to -remain fixtures. Note 4-ForproposedFixture Description, indicate fixture type, lamp type e9 T-��numberoflamps in the fixture, and ballast type lifincludedi. For track lighting, list the length of the track (in feet) in addition to the fixture, lamp, and ballast infomlatiah. Note 5 - Forlighting equipment eligible for exemption perC405.4.1, note exception numberandleave WatI&Fixture blarnk. Note 6 - Existing -lo -remain fixtures shah be included in the Proposed Lighting Wattage table in the same manner as new fixtures. identify as existing in fixture description Note 7 - For proposed WaffsIFIxtureenter the luminaire wattage forinstalted lamp and ballast usingmanufactureror other approved source. For luminaires with screw-in lamps, enterthe manufacturer's fisted maximum input wattage of the fixture (not the lamp grattage). For low voltage lighting, enter the wattage of the transformer. Forline voltage tradvbusway system4 enter the larger of the attached luminalre wattage or 50 wattaNneal foot, or enter the wattage limit of pemmrlent current limiting device. /dote 8 - LobbyArtExhibitDisplayAflowance Is independent of the Maximum Allowed Lighting Wattage. Note 9 - Calculation Area Details: a. Lighting fixtures in a building addition maycompfy as a stand alone project, ortheymay be combined with the overall existing building lighting systems to demonstrate compliance. Referto C502.1. ELECTRICAL SYMBOLS & ABBREVIATIONS LEGEND NOTE: ALL FIXTURES AND EQUIPMENT SHOWN ON PLANS IN STANDARD LIGHT FIXTURES & CONTROLS ABBREVIATIONS (HEAVY) LINE WEIGHT ARE NEW OR RELOCATED WORK. FIXTURES AND EQUIPMENT SHDWN IN LIGHT UNE WEIGHT WITH (E) NEXT TO THEM NOTE: LIGHTING FIXTURE SYMBOLS SHOW LENGTH, A (200A) (AFTER A NUMBER) = AMPS INDICATE EXISTNG TO REMAIN. SYMBOLS SHOWN AS DASHED INDICATE MOUNTING & EMERGENCY EGRESS INFORMATION ONLY. AF(200AF) (AFTER ANUMBER) =FUSE SIZE IN AMPS ITEMS TO BE REMOVED OR DEMOLISHED. THIS APPLIES UNLESS NOTED REFER TO FIXTURE DESIGNATIONS & LIGHTING FIXTURE OTHERWISE ON PLANS. SCHEDULE FOR LAMP TYPE & OTHER FIXTURE SPECIFICS. AFF ABOVE FINISHED FLOOR AHJ AUTHORITY HAVING JURISDICTION POWER RECEPTACLES &OUTLETS AL ALUMINUM O RECESSED DOWNLIGHT (ROUND) ATS AUTOMATIC TRANSFER SWITCH IQ DUPLE( RECEPTACLE ; PENDANT MOUNTED DOWNLIGHT BKR BREAKER (� DOUBL= DUPLEX RECEPTACLE ® SURFACE MOUNTED LINEAR FIXTURE C CONDUIT I1@1 DUPLE( GFCI RECEPTACLE ® RECESSED LINEAR FIXTURE CKT CIRCUIT DOUBLE DUPLEX GFCI RECEPTACLE ® PENDANT MOUNTED LINEAR FIXTURE CL CENTERLINE DUPLE:( RECEPTACLE MOUNTED IN CEILING ® SURFACE MOUNTED LINEAR FIXTURE (NARROW BODY) CLG CEILING �@USB DUPLE:( RECEPTACLE WITH 1/2 USB RECESSED LINEAR WALLWASHER C.O. CONDUIT ONLY k� DUPLE( RECEPTACLE MOUNTED +4"O.C. ABOVE COUNTER RECESSED WALLWASHER CRP CONTROL RELAY PANEL OR BACKSPLASH, WHEN PRESENT (U.O.N.) CU COPPER ©@) RECESSED EMERGENCY EGRESS DOWNUGHT DOUBLE DUPLEX RECEPTACLE MOUNTED +4"O.C. ABOVE ® UNIVERSAL/CEILING MOUNTED EXIT SIGN DIA DIAMETER COUNTER OR BACKSPLASH, WHEN PRESENT (U.O.N.) DISC DISCONNECT UP WALL MOUNTED EXIT SIGN DISP DISPOSER DUPLE( GFCI RECEPTACLE MOUNTED +4"O.C. ABOVE ® EM DIRECTIONAL EXIT SIGN (ARROWS INDICATE ONE OR TWO SIDES COUNTER OR BACKSPLASH, WHEN PRESENT (U.O.N.) DF DRINKING FOUNTAIN AND DIRECTION INDICATED) DOUBLE DUPLEX GFCI RECEPTACLE MOUNTED +4"O.C. ABOVE DW DISHWASHER COUNTER OR BACKSPLASH, WHEN PRESENT (U.O.N.) LIGHTING CONTROLS E.C. ELECTRICAL CONTRACTOR GFCI FECEPTACLE WITH WEATHERPROOF WHILE—IN—USE COVER ECB ENCLOSED CIRCUIT BREAKER WP a SINGLE POLE LIGHT SWITCH (E) EXISTING (USED AS SYMBOL DESIGNATION) DS 2 (LOWER CASE SUBSCRIPT DEFINES LIGHTS THAT ARE TO BE FLUSH FLOOR OUTLET BOX WITH DEVICES SHOWN A SWITCHED—MATCH WITH LETTERS AT FIXTURE) EMT ELECTRICAL METALLIC TUBING SWITCF'ED DUPLEX RECEPTACLE VIA CLOSEST OCCUPANCY S3 THREE POLE LIGHT SWITCH EXTG EXISTING (USED AS ABBREVIATION IN TEXT) � SENSOR FAAP FIRE ALARM ANNUNCIATOR PANEL DOUBLE DUPLEX RECEPTACLE WITH 1/2 SWITCHED VIA S DIMMER SWITCH FACP FIRE ALARM CONTROL PANEL OCCUFANCY SENSOR S OCCUPANCY SENSOR LIGHT SWITCH (NUMBER DEFINES RELAY I® SPECIAL PURPOSE RECEPTACLE NUMBER IN LIGHTING CONTROL PANEL–SEE SCHEDULE) FLR FLOOR SINGLE F.O.I.C. FURNISHED BY OTHERS, INSTALLED OJ JUNCTON BOX WITH BLANK COVER S VACANCY SENSOR LIGHT SWITCH BY ELECTRICAL CONTRACTOR LV LOW VOLTAGE, b = AREA TO BE CONTROLLED, GFCI GROUND FAULT CIRCUIT INTERRUPTER bet R# RELAY IN LIGHTING CONTROL PANEL S# SENSOR ZONE GND GROUND CONDUITS AND CIRCUITING KVA 1000 VOLT AMPERES © CEILING MOUNTED VACANCY SENSOR KW 1000 WATTS WIPING LOCATED IN CEILING OR WALL ® VACANCY SENSOR/PHOTO SENSOR LCP LIGHTING CONTROL PANEL – — — – WIPING CONCEALED UNDER FLOOR OR UNDERGROUND os CEILING MOUNTED OCCUPANCY SENSOR LT LIGHT �– CONDUIT HOME–RUN o ® PHOTOCELL LIGHT SENSOR LTS(LTG LIGHTS LIGHTING � (LIGHTING) ��lfr SLASHES ACROSS CONDUIT INDICATE NUMBER OF WIRES LV LOW VOLTAGE WITHIN — SHORT = HOT, LONG = NEUTRAL MCB MAIN CIRCUIT BREAKER AUDIO/VISUAL DEVICES SERVICE GEAR - AS SHOWN ON PLANS MECH MECHANICAL MLO MAIN LUGS ONLY ❑Q TELEV13ION (RG6 COAX) CIRCUIT BREAKER PANELBOARD N3R NEMA 3R LOAD CENTER NIC NOT IN CONTRACT TELE/COMMUNICATIONS SYSTEM DEVICES T DRY TYPE TRANSFORMER (SEE NOTES & RISER OS OCCUPANCY SENSOR ®W WALL MOUNTED TELEPHONE (VERIFY MOUNTING HEIGHT) DIAGRAM FOR SIZE) PC PHOTOCELL ® SINGLE GANG TELEPHONE/DATA OPENING PNL PANELBOARD Q WAP WIRELESS ACCESS POINT NOTES AND MISCELLANEOUS SYMBOLS PSE PUGET SOUND ENERGY PUD PUBLIC UTiUTY DISTRICT SECURITY SYSTEM EQUIPMENTF: FLAGNOTE – IDENTIFIES A SPECIFIC ITEM ON A DRAWING. REC RECEPTACLE(S) COORESPONDS TO A SCHEDULE IN THE ELECTRICAL SET THAT NOTE: COORDINATE RACEWAY REQUIREMENTS WITH SECURITY VENDOR. EXPLAINS DETAILS OR FEATURES OF THAT ITEM. REF REFRIGERATOR (R) RELOCATED EXISTING cR CARD READER ACCESS OUTLET FF -3 MECHANICAL FLAG – DEFINES MECHANICAL EQUIPMENT AND SCL SEATTLE CITY LIGHT D COORESPONDS TO DESIGNATIONS IN MECHANICAL PLANS AND VIDEO INTERCOM SCHEDULES. COORESPONDS MECHANICAL CONNECTION SCHEDULE SNOPUD SNOHOMISH PUBLIC UTILITY DISTRICT Do DOOR OPENER IN THE ELECTRICAL SET. SW SWITCH DQ SECURTY CAMERA 200 EQUIPMENT FLAG – DEFINES SPECIAL (IE: COOKING) EQUIPMENT TBD TO BE DETERMINED ON A PLAN AND COORESPONDS TO DESIGNATIONS IN AN TTB TELEPHONE TERMINAL BOARD EQUIPMENT CONNECTIONS & CONTROLS EQUIPMENT SCHEDULE IN THE ELECTRICAL SET. TYP TYPICAL REVIEWED F OR ® EQUIPMENT CONNECTION REVISION CLOUD AND FLAG CLOUD SURROUNDS INFORMATION - U.O.N. UNLESS OTHERWISE NOTED EQUIPMENT THAT HAS BEEN REVISED. FLAG IDENTIFIES THE REVISION IN VM VARIABLE FREQUENCY DRIVE COMPLIANCE WITH WALL MOUNTED CONNECTION 1 WHICH THE CHANGES WERE MADE. NFPA 70 - NEC I� MOTOR CONNECTION VS VACANCY SENSOR WAP WIRELESS ACCESS POINT FAN CONNECTION SEP 13 2016 W/0 WITHOUT Su MOTOR RATED SWITCH WP WEATHERPROOF (l PADDLE FAN XFMR TRANSFORMER City of Tukwila BUDDING DIVISION REVISIONS FNonces shad be m o"k t^�itha>� 'd� to the scope P'7or P-40prov t;Lf?,tdin Divi toilDi of;:tr,5a,3 Lill r�q(,rire a R,�tt/. . f and may ire'odL add',tianat L � an submittal pian revie��.► fees. E� 1 ", IE A PERs1iT UE"J FOR. 01f."No'chanieW Electrical 23TIumbing MoGa.S PI Cli",+ of Tulwwla Permit Ala. Plan rov1,9W a royA AP 1 is subject to errors and 0missiors. Approval sof cOnsiriiction documents does not au'lhorize the violation of any adopted cede or Ordinance. R-cceipf Of approvad ield Copy and conditions is acknO%Iedged: [IV: CRY sof Tu la BUILDING DIV1,S1011 '•Uelff D514 EO.1 ELECTRICAL LEGEND & SCHEDULES EO.2 RISER DIAGRAM & SCHEDULES EO.3 PANEL SCHEDULES E1.1 POWER & COMMUNICATIONS FLOOR PLANS E2.1 LIGHTING FLOOR PLAN EL2.1 LIGHTING EGRESS CALCULATION TITAN ELECTPJC FULL SERVICE ELECTRICAL CONTACTOR 12828 NORTHUP WAY, SUITE 205 BELLEVUE, WA 98005 PH: 425-250-2581 FA: 206-374-2128 CA�) ENGINEERING Consulting Electrical Engineers 19515 North Creek Parkway, Suite 302 Bothell, Washington 98011 Phone: 425-402-9400 Fax: 425-402-9402 Project Title: Tenant Improvement for: NW Hydraulics Gateway Corp. Ctr. Bldg 6 12787 Gateway Dr. Tukwila, WA 98168 Sheet Title: ELECTRICAL LEGEND AND SCHEDULES RECEIVED Designed By: CITY OF TUKWILA Drawn By: SEP 07 2016 PERMIT CENTER Project No: Date: Sheet Number: TN BY 16229 09/07/2016 PKII 1888W 48GY/ 1000 SEATTLE CITY 1000 LIGHT M M Il,OOAC cm 3 r'�J 200A BUSSED I GUTTER RISER DIAGRAM NOT TO SCALE LEGEND NOTES 200 EXISTING FEEDER SIZE IN AMPS EDSOLID SHADING IN HEAVY LINES INDICATES NEW WORK IN THIS CONTRACT. PARTIAL SHADING IN LIGHT LINES INDICATES LJ EXISTING EQUIPMENT THAT HAS BEEN MODIFIED IN THIS CONTRACT. 32,500 AVAILABLE FAULT CURRENT (IN AMPS) 9 90 75 kVA 200 XFMR 2"C-4#3/0 CU & 1#6 CU GND 9,814 90 75 kVA 200 %I— XFMR 1 1/4-C-3#3 CU & 1#8 CU GND 4cVA 4,408 FIR%f 2"C-4#3/0 CU & 1#4 CU GND 1ST FLOOR #4 -REVIEWEE) FOR COMPLIANCE ?,"TI -1 NFPA 70 13 2016 CitY k vita` Mgt.. --- - _ TITAN ELECTRIC FULL SERVICE ELECTRICAL CONTACTOR 12828 NORTHUP WAY, SUITE 205 BELLEVUE, WA 98005 PH: 425-250-2581 FA: 206-374-2128 19515 North Creek Parkway, Suite 302 Bothell, Washington 98011 Phone: 425-402-9400 Fax: 425-402-9402 Hydraulics RISER DIAGRAM Designed By: TN Drawn By: BY Project No: 16229 Date: 09/07/2016 Sheet Number: PANEL H3 PROJECT NAME NW HYDRAULICS PROJECT #. 16229 LOCA710M FED FROM NOTE CKT NO. CIRCUIT NAME CB SIZE LOAD(1KVA) PANEL DESCRIPTION 0 AMF P R H M L K O TOTAL 24 52.8 1 PUMP A 40 3 € 7.6 PHASE B KVA : AMPS : 52.5 189.4 7.6 PANEL AMPS : 225 FEEDER AMPS : 200 L - L VOLTS : 480 -- 3 5 - ....................................................... - B - ..... ...... ....... C - - .... - i 7.6 ................................................. ;................ € 7.6 ................ ................ 7.6 .................. 7.6 9.9 7 PUMP 4 A 50 3 € 11.1: 44 - d2 - ................ ....................................... ..... - 11.1 L - N VOLTS : 277 PHASE: 3 LNPF : 4 11.0 a ....... ......... >............... ................................................ 8.2 9 11 - ..__�__.._...__.-._.-._-__..___.__..........................................................................., - B. C - ....................�...............�............,...;.....................,........................................,.. 11.1 0.4 A 20 .................... B 20 ..... C 20 11-1 CORD REEL COED t?E� CORD REEL 13 LTS- LAB A 20 1 € 1.5 15 1.9.. ....................................................................................................................... 21 1.5 M L.O. 15 -. 17 SPARE ....................................................................................................... SPARE B 20 C 20 1 1 ............... ....................................... ........... M.L.O. MAIN CB ..... 0.6 19 SPARE A 20 1 20DA 1 23 CORD REEL - - M L.O. MAIN CB FLUSH X 1.5 3 21 23 SPARE SPARE B 24 C.......1 1 .................................................................................................................. -- 25 CORD REIT _ A 20 1 25 SPACE A - 1 1 ................ 1.5 SURFACE X SURFACE X 27 CRDFO 27 29 SPACE SPACE B - C - 1 1.............................................................................................................. -- ................ 1,5 ISD. GND FEED-THRU ..... ............ ..... ................ ;................ ................ 31 33 SPACE SPACE A - R ....._........................................ 1 ............... ,................................................ rl ...... ............ x SPACE PUMPS SPARE SPARE SPARE SPARE 10.8 -- LOADSUMMARY SPACE SPACE- ( T:) -A-. AIL L SECT REID KVA : HEAT KVA : CUS' 29.1 10.8 10.8 1b.8 MOTOR KVA : 120.8 10.8 LIGHTING KVA : KITCHEN KVA 1.5 10.8 10.8 OTHER KVA : PHASEA KVA : 24 52.8 100% _ AMPS : 190.7 ......... PHASE B KVA : AMPS : 52.5 189.4 1 1 ......... PHASECKVA: A MPS -. 48.5 175.0 L LIGHTING -- 28 30 SPACE SPACE- B- C..............1...............................................;....................................... 1 € [ CIRCUIT NAME ....................... R RECEPTACLES - TO 1OKVA 100% = 10.0 32 SPACE A - 1 K H HEATING 100% _ CONNECTED LOAD M MOTORS 34 36 SPACE ...........................................................................................�................c................;..,...........................................,................... SPACE B - C - 1 1 125% = 41.6 PANEL AMPS : 225 L LIGHTING KVA : 153.8 AMPS: 185.0 = 1.9 38 PANEL R3 VIA 75KVA XFMR A 100 3 9.9 O OTHER 1.2 11.1 DEMAND LOAD -- 44 - d2 - ................ ....................................... ..... - B - .....-........................ C - 11.0 a ....... ......... >............... ................................................ 8.2 0.4 1.2 ...... 12.2 ... ....... 8.2 KVA : 152.9 AMPS : 183.9 NOTESIREMARKS : 1- DEM AND I DIV ERSITY FACTORS LOCATION: FED FROM: LOAD DESCRIPTION DEMAND CIRCUIT NAME 2. R RECEPTACLES - TO 1OKVA 100% = 10.0 3. REMAININ3OVER 10KVA 60% = 9.5 K H HEATING 100% _ 1 3 5 M MOTORS 100% = 87.6 1.3 ........................................... 1.3 € 1.3 LM LARGEST MOTOR 125% = 41.6 PANEL AMPS : 225 L LIGHTING 125% = 1.9 77 .............................................................................................................................................:..................................................------ 9 11 K KITCHEN 100% = 1.3 1.3 1.3 O OTHER 100% = 2.4 PANEL P-3 PROJECT NAME NW HYDRAULICS PROJECT it 16229 LOCATION: FED FROM: NOTE CKT NO. CIRCUIT NAME CB SIZE -AMP LOAD(KVA) PANEL DESCRIPTION $ P R H M L K O TOTAL ............................................................................................... 1 3 5 6-20R .................................................................................. 6 20R A 20 B - C 20 2 - 2 1.3 ........................................... 1.3 € 1.3 1.5 5.0 6.8 PANEL AMPS : 225 1.3 1.3 1.3 PANEL AMPS : 225 FEEDER A NPS : 200 L- L V OLTS : 208 L- NVOLTS : 120 PHASE: 3 WRE : 4 - 77 .............................................................................................................................................:..................................................------ 9 11 - 208 A - B 20 C - - 2 - 1.3 1.3 1.3 4.6 5.7 FEEDER AMPS : 200 L - L VOLTS : 480 L - N VOLTS : 277 PHASE : 3 WIRE : 4 1 ....:...................................... ................ H1.3 1.3 RTU -6 ........................................................................ ................... 13 REC- LAB A 20 11 0.4 ........ ................ 2.2 2.2 .................. 2.2 2 2 2 13 15 17 0.4 A 20 .................... B 20 ..... C 20 15 1 ! 19 CORD REEL COED t?E� CORD REEL BZO..........:5 C 20 ... ............ 20 1 ..... I 1 ............................................................_ 1.5 ................ >........................................................._ 1.5 2.0 1.6 1.6 1:2 15 1.9.. ....................................................................................................................... 21 1.5 1.5 1.5 M L.O. 1 21 CORD REEL B 20 1 1.51.5 M.L.O. MAIN CB 0.6 0.6 1MFiE : 4 23 WINCE FLUSH X 20DA 1 23 CORD REEL - - C 20 1 1.5 3 15 .......................................................................................................................................................... 25 27 1.5 -- 25 CORD REIT _ A 20 1 1.5 17 SURFACE 180 GND - ..................... 1 ................ 1.5 SURFACE X C - 1 27 CRDFO B 20 1 1.5 - FEED THRU -- ................ 1,5 ISO GND FEED-THRU ..... ............ ..... ................ ;................ ................ 29 SPARE C 20 1 •• rl MAIN CB x 200A 1,3 31 SPARE A 20 1 i ................ ................................................................................................................................ .................. ......................................>. .................................................................................. 1,3 33 SPARE B 20 1 _. -- -- ...................................... SURFACE X 1,3 1,3 35 SPARE C 20 1 2 SPARE A 20 1 110 GND FEED-THRU i f I -O TAL,ALL BEC -TOES 1 37 SPACE A - 1 6 20 1 RKY KVA : 9.0 3.3 2 FURNITURE FEED- OPEN OFFICE 117 LOAD SUM MARY - 3 SPACE - g - 1- : .._...~... _..-. :2- 2.2 -_. - -� 2.2 (TC TAL, ALL SEC-IOASI 10 41 SPACE C - 1 - - MOTOR KVA : 0.7 3 3 - ..................... KTfCF{EN KVA ................ REC KVA : 29.1 -12.2 2 6-20R A 20 2 1.3 1 C 2.2 OTHER KVA 13.7 1.2 r2.5 RTU -1 4 6 - 6-2DR B - C 20 - 2 1.3 1.3 0.2 1.3 2 1.2 2.5 1.3 HEAT KVA MOTOR KVA - 8 - A - - 1.3 PHASEA KVA : 25.5 C 18 - - 1.3 LIGHTING KVA 1.3 10 6-208 B 20 2 1.3 2,3 20 PUMP 5 50 1.3 KITCHEN KVA 1 0.7 1 0.7 11.1 PHASEB KVA : 27.2 MOTOR KVA 22 - B A 20 1.3 OTHER KVA : 2.4 - 14 6-20R A 20 2 1.3 •; - C - - 11.1 1.3 D.D. 16 - - - B - - - 1.3 SPACE 1 1 1 - ..................... ................. 1.3 PHASEA KVA : 11.1 AMPS ; 92.2 OTHER KVA . 13.7 PHASEA KVA : 6.8 18 SPARE C 20 1 SPACE B _ 1 0.2 ................ ................................. 0.9 AMPS : 56.5 PKIASEB _ KVA . 7 AMPS : 47.5 PHASECKVA 5.5 AMPS : 45.0 CONNECTED LOAD KVA : 18.0 ---- 20 SPARE - A 20 1 ( C _ 1 ............ 1,3 30 PHASE B KVA : 17-2 B 20 22 SPARE - B 20 1 '- - ..................... ................. AMPS : 101.7 24 SPARE C 20 1 _ ...................................... .................................................... ..................... --.... .............. .................PHASE C KVA : 8.2 AMPS . 68.3 26 SPARE A 20 1 _ AMP : 92.1 --- 28 -'SPARE SPARE B 20 1 R RECEPTACLES- TO 10KVA 100% = 4.3 REMAINING OVER 10KVA 50% _ H HEATING 1000/0 = M MOTORS 1009/0 = LM LARGEST MOTOR 1259/o _ L LIGHTING 125% _ K KITCHEN 1000/0 _ O OTHER 1000/0 = 13.7 DEMA ND LOA D KVA : 87.0 '"j0 C 20 1 - ..................... AMP : 104.6 ................. DEMAND DIVERSITY FACTORS LOAD DESCRIPTION DEMAND 32 SPACE Al CONNECTED LOAD 34 SPACE B - KVA . 31.5 AMPS : 87.3 DEMAND LOAD kVA : 21.9 AMPS 60.9 : ................................................................................................................................................. 36 38 SPADE SPACJ................................................................................................. G - A...................................... -......... ................................................__ .. ................ ............... .......... _._ -- 42 SPACE C _ NOTESIREMARKGS : 1. 2• 3• DEMAND/ DIVERSITY FACTORS LOAD DESCRIPTION DEMAND R RECEPTACLES - TO 10KVA 100% = 10.0 REMAINING OVER 10KVA 51)1% = 9.5 H HEATING 100% _ M MOTORS 100% _ LM LARGEST MOTOR 125% _ L LIGHTING 125% K KITCHEN 100% _ 0 OTHER 100% = 2.4 (E) PANEL H2 PROJECT NAME IWV HYDRAULICS PROJECTM 16229 LOCATION: FED FROM NOT CKf NO. CI RCUT NAME CB SIZE 16FAMP I LOAD(KVA) PANEL DESCRIPTION 8 AMP PI R I H I M L K 1 O TOTAL 1 1 75 KVA XFMR TO PANEL R2 A 90 31 1.8 1 1.5 1.5 5.0 6.8 PANEL AMPS : 225 ...............��..................................................................................................................... 3 - B - C ....._ - - 1.1 - .....1.4....:............ ......... 1.5 ................4.1..........x.5.... 4.6 5.7 FEEDER AMPS : 200 L - L VOLTS : 480 L - N VOLTS : 277 PHASE : 3 WIRE : 4 1 ....:...................................... ................ 7 .... 1.1...._............................................................................................. RTU -6 ........................................................................ ................... A 25 B . C................. - 3 - ......... ......... 2.2 .. :................... 2.2 .............................................................................. € 2.2 ......... ........ ........ ................ 2.2 2.2 .................. 2.2 2 2 2 13 15 17 LTS - NORTH .............................................................. ............................................... Ll8 -NORTH _........................................................ LTS - TRARISCRIFT ROOM .......... A 20 .................... B 20 ..... C 20 1 1 1.. ............. ....:................ ................ € € ................................................................................................ 2.D ..... ............................................................. 1.fi 1.6 1 FURNITURE FEED- OPEN OFFICE 138 B 20 2.0 1.6 1.6 1:2 15 1.9.. ....................................................................................................................... 21 SPACE SPACE A - . B ..............1 ' 1 ...............;...............,............... ............ .... ... ............................................... 1 MW- LUNCH ROOM 124 M.L.O. MAIN CB 0.6 0.6 1MFiE : 4 23 SPACE C - 1 1 20 1 0.4 0.6 0.6 FLUSH 3 15 .......................................................................................................................................................... 25 27 SPACE SPACE A _ g - 1 1 €€ ................:................:.................................................................................. 0.6 X 3 17 SURFACE 180 GND X 1 20 j 1 29 SPACE C - 1 3 19 FURNITURE FEED- OPEN OFFICE 138 A 20 1 FEED THRU 0.6 ................ ............ .................................................................................................................... ..... ............ ..... ................ ;................ ................ ............... ........ ........................................... 1 j ISO GND FEED THRU rl MAIN CB x 200A 1,3 23 SPARE C 20 1 ................ ................................................................................................................................ .................. ......................................>. .................................................................................. 1,3 25 SPARE -- - A 20 LOADSUMMARY f TDTn L.n__ SE=TIONE I I -- -- -- SURFACE X 1,3 1,3 27 29 SPARE SPARE - RLQ KVA : 4.3 2 2 SPARE A 20 1 110 GND FEED-THRU i f I -O TAL,ALL BEC -TOES 1 2 4 LTS - SOUTH 6 20 1 RKY KVA : 9.0 3.3 2 FURNITURE FEED- OPEN OFFICE 117 3.3 HEAT KVA MOTOR KVA 50.1 LIGHTING KVA : 8.4 - 1 6 -- 8 SPADE- -- RTAS_._..._.�_....._....._.._._._...__...�_. G - A 25 1 3 .._...~... _..-. :2- 2.2 -_. ._ -� 2.2 3 10 - B - 20:1 ; 2,2 ': - 0-7 MOTOR KVA : 0.7 3 3 2.2 KTfCF{EN KVA A B 12 -12.2 0.4 0.4 LIGHTING KVA KITCHEN KVA : 4.6 LOADSUMMARY 12 iREC- TOOL SHOP C 2.2 OTHER KVA 13.7 1 14 RTU -1 A 15 3 ? 1.3 - I - 0.2 0.2 1.3 2 16 - B - - I 1.3 2 FURNITURE FEED Al20 1.3 PHASEA KVA : 25.5 C 18 - - C - - 1.3 B 20 1 A 1.3 AMPS : 91.9 2,3 20 PUMP 5 50 3 - 11.1 1 0.7 1 0.7 11.1 PHASEB KVA : 27.2 MOTOR KVA 22 - B A 20 1"'--d.-21.1 I-- 26 28 0.4 0.5 AMPS : 98.4 3 Za - C - - 11.1 C ................... D.D. 1.1 11.1 PHASECKVA 23.8 12 14 16 26 SPACE 1 1 1 0.7 j ................>-.................................................................................. 0.5 0.4 ? 0.2 0.4 - 0. f 0.7 0.7 OTHER KVA . 13.7 PHASEA KVA : 6.8 3 1,3 .......................................................................................................................................................................................:................: 3 AMPS : 86.0 FSG- RATION 100 SPARE SPARE 28 SPACE B _ 1 0.2 ................ ................................. 0.9 AMPS : 56.5 PKIASEB _ KVA . 7 AMPS : 47.5 PHASECKVA 5.5 AMPS : 45.0 CONNECTED LOAD KVA : 18.0 1,3 1,3 1.3.......28...SPARE 24 26 SPARE SPARE .............................................................................................. B 20 C 20 A ...20....1.... 30 SPACE C _ 1 ............ 1,3 30 SPARE .................................................................................................................. B 20 1 ................. ................ ................................................................................................... ................ ................ ................ ................... '- CONNECTED LOAD - - - AMPS : 50.0 ...................................... .................................................... ..................... ............... ............... ................ ................ KVA : 76.5 ........ ........................... CEIVAND LOAD KVA : 18.0 - - - -- - _ AMP : 92.1 AMPS : 50.0 NOTESIREMARKS: 1. REMOVE EXISTING CBANDPROVIDE (1) NEW 20AI1P CEL Z EXISTING CIRCUIT, NO NEW LOAD. 3. NEW WORKS LOAD CHANGED. DEMANDI DIVERSITY FACTORS LOAD DESCRIPTION DE WAND R RECEPTACLES- TO 10KVA 100% = 4.3 REMAINING OVER 10KVA 50% _ H HEATING 1000/0 = M MOTORS 1009/0 = LM LARGEST MOTOR 1259/o _ L LIGHTING 125% _ K KITCHEN 1000/0 _ O OTHER 1000/0 = 13.7 DEMA ND LOA D KVA : 87.0 AMP : 104.6 NOTESIREMARKS: 1. EXISTING CIRCUIT, NONEW LOAD. 2. NEW WORK LOAD ADDED. 3. PROVIDE (1) NEW 5OA13P CB IN AVAILABLE SPACE DEMAND DIVERSITY FACTORS LOAD DESCRIPTION DEMAND R RECEPTACLES- TO 14KVA 100% = 4.3 REMAINING OVER 10KVA 50% H HEATING 1009/0 = M MOTORS 1DD9/o = 16.8 LM LARGEST MOTOR 125% = 41.6 L LIGHTING 1259/o = 10.6 K KITCHEN 100% = O OTHER 100% = 13.7 (E) PANEL P-2 PROJECT NAME NW HYDRAULICS PROJE33T#: 16229 LOCATION: FED FROM: NOTE CKT NO. CIRCU-NAME CBSIZE LOAD(KVA) PANEL DESCRIPTION 8 AMP P R H M L K O TOTAL 3 1 SERVER -SERVER 129 A 20 1 3.6 100% = 1.5 1.5 PANEL AMPS : 225 3 3 R -OTTER- PLOTTERROOM 103 B 20 1 8.1 A 1.5 1.5 F EEDER AMPS : 2DO L - L VOLTS : 208 L - N VOLTS : 120 3 5 PLOTTER - PLOTTER ROOM 103 C 20 1 ( `: I 0.7 1.5 1.5 3 7 RFC- PRNATEOFFICES 131, 132, 133 Al20 1 1.1 I 3 0.5 1.6 3 9 1 FURNITURE FEED- OPEN OFFICE 138 B 20 1 1:2 15 0.6 0.6 PHASE : 3 3 11 FURNITURE FE®- OPEN OFFICE 138 C 20 1 MW- LUNCH ROOM 124 C 0.6 0.6 1MFiE : 4 3 13 FURNITURE FEED- OPEN OFFICE 138 A 20 1 20 1 0.4 0.6 0.6 3 15 FURNITUFiE FEED- OPEN OFFICE 138 B 205 B 1 1.8 0.6 0.6 X 3 17 FURNITURE FEED- OPEN OFFICE 138 C 20 1 20 j 1 1.8 0.6 --- 0.6 3 19 FURNITURE FEED- OPEN OFFICE 138 A 20 1 20 11 0.6 0.6 M.L.O. 1:2 1 3 21 LTS - UC B 20 1 j ISO GND FEED THRU rl MAIN CB x 200A 1,3 23 SPARE C 20 1 FLUSH 1,3 25 SPARE -- - A 20 1 I -- -- -- SURFACE X 1,3 1,3 27 29 SPARE SPARE - B 20 C 20 1 1 i I i 110 GND FEED-THRU i f I -O TAL,ALL BEC -TOES 1 f I RKY KVA : 9.0 3 2 FURNITURE FEED- OPEN OFFICE 117 A 20 11 1.2 1.2 3 4 FORNn-uRE F®- OPEN OFFICE 117 B 21) 11 1.2 1.2 FEAT I{VA : 3.6 3 6 SW FURN. FE@- OPEN OFFICE 117 C 20:1 0.7 ': - 0-7 MOTOR KVA : 0.7 3 3 8 10 RED- TOOL SHOP REC- TOOL SHOP -- A B 20 1 2D ; 1 0.4 0.4 0.4 0.4 LIGHTING KVA KITCHEN KVA : 4.6 LOADSUMMARY 12 iREC- TOOL SHOP C 20 20.2 -3- _ _ i 0.2 OTHER KVA : 8.1 1,2 14 rT]TAL.n__ SE=TIONE I A - I - 0.2 0.2 2 16 REF B REC KVA : 4.3 2 2 FURNITURE FEED Al20 1 ? C 1.2 1.2 2 4 FURNITURE F® B 20 1 A -.t-, 20 1 1.2 1.2 FEAT KVA 2 6 FURNITURE FEE) C 20 1 0.7 1 0.7 1.2 1.2 MOTOR KVA 3 8 REC- PRIVATEOFFICES 134,135 A 20 1"'--d.-21.1 I-- 26 28 0.4 0.5 LIGHTING KVA 3 10 REG- PRICe4TE OFFICES 135, 136 B 20 1 D.7 C ................... D.D. 1.1 KITCHEN KVA 3 3 .................................. 3 12 14 16 REC- LARGECONFERENCE 107 Ri C- FRNATEOFFICE103 .................................................................................... REC--PRKIATEOFFICE101, 102 C 20 A 20 ...... . B 20 1 1 1 0.7 j ................>-.................................................................................. 0.5 0.4 ? 0.2 0.4 - 0. f 0.7 0.7 OTHER KVA . 13.7 PHASEA KVA : 6.8 3 1,3 .......................................................................................................................................................................................:................: 3 18 20 22 FSG- RATION 100 SPARE SPARE G 20 A 20 B 20 1 1 1 0.7 ................................................................................... ............... ................. 0.2 ................ ................................. 0.9 AMPS : 56.5 PKIASEB _ KVA . 7 AMPS : 47.5 PHASECKVA 5.5 AMPS : 45.0 CONNECTED LOAD KVA : 18.0 1,3 1,3 1.3.......28...SPARE 24 26 SPARE SPARE .............................................................................................. B 20 C 20 A ...20....1.... 1 1 s .................................................................................................. ....>... ......... ......... ........ ........ ......... ............ 1,3 30 SPARE .................................................................................................................. B 20 1 ................. ................ ................................................................................................... ................ ................ ................ ................... AMPS : 50.0 ...................................... .................................................... ..................... ............... ............... ................ ................ ................ ........ ........................... CEIVAND LOAD KVA : 18.0 ' AMPS : 50.0 NOTESIREMARKS: 1. REMOVE EXISTING CBANDPROVIDE (1) NEW 20AI1P CEL Z EXISTING CIRCUIT, NO NEW LOAD. 3. NEW WORKS LOAD CHANGED. DEMANDI DIVERSITY FACTORS LOAD DESCRIPTION DE WAND R RECEPTACLES- TO 10KVA 100% = 4.3 REMAINING OVER 10KVA 50% _ H HEATING 1000/0 = M MOTORS 1009/0 = LM LARGEST MOTOR 1259/o _ L LIGHTING 125% _ K KITCHEN 1000/0 _ O OTHER 1000/0 = 13.7 PROJECT NAME LOCATION NOTE CKT NO. 1 1 75KVA 3 5 - 1 1 7 RTU -2 1 23 SPACE NW HYDRAULICS CIRCUIT NAME 7R -TO P-1 NOTESIRE4IARKS : 1. EXISTING CIRCUIT, NO NEW LOAD. 2 3. (E) PANEL H1 FED FROM: CB SIZE I LOAD(KVA) DAMP R I H M L K 4 90 31 2-5 1 ` 3 - - 3.4 1 1.8 j 1.E - - 3.1 € 1.8 0.7 € 3.( k 15 3 1.3 22 22 2.2 22 1.7 (i1b DEM AND I DIVERSITY FACTORS LOAD DESCRIPTION R RECEPTACLES - TO 10KVA 200 REMAINING OVER 10KVA H HEATING M MOTORS LM LARGEST MOTOR L LIGHTING K KITCHEN O OTHER PROJ MT #.' 16229 1 ?TALI PANEL DESCRIPTION 6.2 PANELAMPS : 225 9.5 FEEDERAMPS : 200 10.3 L - L VOLTS ; 480 1.3 L - N V OLTS : 277 13 PHASE: 3 1.3 WIRE ; 4 2 M.L.O. MAIN CB FLUSH SURFACE X ISO GND FEED-THRU INA : LOADSUMMARY I II I AI 41 I :1 1: RE3-- KVA : HEAT KVA : MOTOR KVA : LIGHTING KVA : KITCHEN KVA : OTHER KVA : PHASEA KVA : AMPS : PHASE B KVA : AMPS : PHASECKVA : AMPS : 1111.!: 1 9.0 3.6 22.7 4.6 8.1 13.5 48.8 16.9 60.9 17.6 63.6 57.7 EMA ND LO.A D CKT NO 22 2.2 2-2 1-7 1.7 1.7 - AM PI INA : 48.0 AMPS : 57.7 EMA ND LO.A D CKT NO KVA : 49.6 AMPS : 59.7 8 AM PI R H M L K 0 TOTAL DEMAND 1 100% = 9.0 500/0 = 0.5 100% = 3.6 100% = 16.2 125% = 8.1 125% = 1000A = 4.6 100"!0 = 8.1 REVIEWED OR COMPLIANCE WITH FPA 70 -ITEC SEP 13 2016 City of TukWila i 01111 nlKln nnnr%te._. r w�rw�■ w�A a.dl W IVIG Ji a (E) PANEL P-1 PROJECT NAME NW HYDRAULICS PROJMT #: 16229 LOCATION FED FROM NOTE CKT NO CIRCUIT NAME CBSIZE LOAD(KVA) PANEL DESCRIPTION 8 AM PI R H M L K 0 TOTAL 3 1 REC- EQUIPMENT STORAGE Al20 ! 1 0.5 10.5 PANEL AMPS : 225 FEEDERAMPS : 200 L - L VOLTS : 208 L - N V OLTS : 120 PHASE : 3 3 3 3 5 PRINTER- PRNTICXOPY 114 FURNITURE FEE) - OPEN OFFICE117 B C 20 1 1 20 11 1.5 1.5 1.2 1.2 3 7 FURNITURE FEED - OPEN OFFICE 117 A 20 1 1.2 1.2 3 9 SW. FURR FEED - OPEN OFFICE 117 B 20 11 0.7 `: I 0.7 -3 11 REG -PRIVATE OFFICE 116, 118, 120 C 20 :1 1.1 € 0.5 1.6 WIRE: 4 3 13 RECB PROJ. - MUATIPURFOSE ROOM 119 A 20 1 0.4 0.4 0-7 1:2 15 RED- CHILL ROOM B 20 1 0.5 `_. 0.5 3 17 MW- LUNCH ROOM 124 C 20 11 1.5 1.5 121 19 1 REC- BREAKROOM A 20 1 0.4 ; 0.4 M.L.O. 1:2 2 1 HINT B 20 j 1 1.8 1.8 MAIN CB X 200A 1,2 23 HINT C 20 j 1 1.8 1.8 FLUSH 1 25 _ FURNITURE FEED- WORKSTATION 111 A 20 11 i 0.9 0.9 - SURFACE X 1:2 1 27 29 RED- BATHROOM MAN- LUNCH ROOM 124 - B C 20 ' 1 20 11 0.4 -- 0.4 I 1 5 I 1.5 f ISO GND FEED THRU rl - -- _ i I LOADSUMMARY i i f I -O TAL,ALL BEC -TOES 1 f I RKY KVA : 9.0 3 2 FURNITURE FEED- OPEN OFFICE 117 A 20 11 1.2 1.2 3 4 FORNn-uRE F®- OPEN OFFICE 117 B 21) 11 1.2 1.2 FEAT I{VA : 3.6 3 6 SW FURN. FE@- OPEN OFFICE 117 C 20:1 0.7 ': - 0-7 MOTOR KVA : 0.7 3 3 8 10 RED- TOOL SHOP REC- TOOL SHOP -- A B 20 1 2D ; 1 0.4 0.4 0.4 0.4 LIGHTING KVA KITCHEN KVA : 4.6 1.2 12 iREC- TOOL SHOP C 20 20.2 -3- _ _ i 0.2 OTHER KVA : 8.1 1,2 14 - A - I - 0.2 0.2 2 16 REF B 20 1 1.6 PHASEA KVA : 6.2 2 98 REC- BREAKROOM C 20 1 1 0.2 I 0.2 AMPS : 51.5 2 20 RED- OFFICES NORTH A -.t-, 20 1 0.5 --i-_- 0.5 PHASE B KVA : 9.5 2 22 REC- OFFICES NORTH B 20 11 0.7 1 0.7 AMPS : 79.3 PHASECKVA : 10.3 2 24 RED- OFFICES NORTH C 20 1 1 0.7 0.7 1,2 1 26 28 RED- PANEL RED- LUNCH ROOM 124 A B 20 11 1 20 0.2D 0.7 0.2 .7 AMPS : 85.6 CONN TED LOAD KVA AMPS : 72.1 1,2 30 B(HIAU.UST FAN& RTU REC C ................... 20 1 ..... 0.2 0.7 ................ ................ ................ ................ ................ ................ ................ ................ ............... 0.9 ................ .............. ..... ............... ................ ................... ............................ € ........................ € € DEW D : 25.7 : 7VIE NOTESIREMARKS: DEMAND I CIV ERSITY FACTORS 1. REMOVE EXISTING CBANDPROVIDE (1)NEW 20A11P LOAD DESCRIPTION DpVIA(D CB. R RECEPTACLES - TO 10KVA 1000A = 9.0 Z EXISTING CIRCUIT, NO NEW LOAD. REMAINING OVER 10KVA 5(rX, - 3. NEW WORK LOAD CHANGED. H HEATING 1000/0 = 3.6 M MOTORS 100% = LM LARGEST MOTOR 125% = 0.8 L LIGHTING 125% _ K KITCHEN 909/0 = 4.1 0 OTHER 100% = 8.1 TITAN ELE CTRI C FULL SERVICE ELECTRICAL CONTACTOR 12828 NORTHUP WAY, SUITE 205 BELLEVUE, WA 98005 PH: 425-250-2581 FA: 206-374-2128 19515 North Creek Parkway, Suite 302 Bothell, Washington 98011 Phone: 425-402-9400 Fax: 425-402-9402 Project Title: Tenant Improvement for: NW Hydraulics QII Gj GENERAL NOTES 1. CIRCUIT NUMBERS SHOWN REFER TO PANEL P-1, P-2, OR P-3. SEE BREAKLINES, THIS SHEET. 2. CIRCUIT NUMBERS SHOWN INSIDE () ARE TO BE SWITCHED VIA CLOSEST RELATIVE OCCUPANCY SENSOR PER 2015 WSEC C405.10. — X—X—X—:'.— —X—X i s NORTH POWER & COMMUNICATIONIS FLOOR PLAN SCALE: 1/8" = 1'-0" - REVIEWED FOH COMPLIANCE "I' TH NPPA 70 - NEC SEP 13 2016 City ®f-TukWiaa BUILDING DIVISini,,,i RECEIVED CITY OF TUKWILA SEP 07 2016 TITAN ELECTRIC FULL SERVICE ELECTRICAL CONTACTOR 12828 NORTHUP WAY, SUITE 205 BELLEVUE, WA 98005 PH: 425-250-2581 FA: 206-374-2128 19515 North Creek Parkway, Suite 302 Bothell, Washington 98011 Phone: 425-402-9400 Fax: 425402-9402 Project Title: Tenant Improvement for: Nk'rw Hydraulics POWER & COMMUNICATIONS FLOOR PLAN Designed By: TN Drawn By: BY Project No: 16229 Date: 09/07/2016 Sheet Number. E1.1 GENERAL NOTES 1. CIRCUIT NUMBERS SHOWN REFER TO PANEL H2 UNLESS OTHERWISE NOTED. 2. REFER TO LIGHTING FIXTURE SCHEDULE, SHEET E0.1, FOR ADDITIONAL INFORMATION. FLAG NOTES 1� DAYLIGHT CONTROLLER SWITCHES TWO SETS OF FIXTURES. ZILV s% X 1 F7 17/ H3-113 1-7 17 M g,h.k, 17 TOOL SHOP Q EQUIPMENT F1 (E) I'll (E) Fl(E)i Fl(E) F1 (E) S10 OPEN 122 PI STORAGE 17h/S9 _17 S9 17h/ gL — -F' — ---- __�q — 17g/$9 15S9 ii it i i F1 (E) F1 (E) F1(E) !Fl(E) F1 (E) F7 F7 F7 17 1717 17 17 iii li 1 LV 71 1 B1 il lit it j 17k/S9 it 17m/S9 17k/S9 17m/S91, 17k/S9 it .1 171 1 1 F6 F6 S L 17/S9 17/S9 17/S9 17/S9 17/S9 j H3 -13/S10 H3 -13/S10 Fl-(E)-t3/S8 Fi( F1 (E) F1 (E) F1 (E) F1 (E) F1 (E) F7 S8 PRINT/17 17 17 tl COPY 17 ®X1(E) 13/S8 lit OR STORAGE 121 Ly V SHOWER F1 F1 F1 F1 li F1 (E) F1 (E) fi 1 F126 13 13 Ef3 13 F -3 M13 i 11 - --�= —JA—N. ij L�J`11 F7 OFFICE F1 (E) 113/S8..` 1 16 OFFICE OFFICE OFFICE .5 L H. 113 L 118 L120 J 15 FZ it 13 V SC====3 I F1 (E) 13 OFFICE F1 (E) 112 13 F1 (E) 13 ID OFFICE F1 (E) 13 I'll (E) 13 OFFICE F1 (E) 108 13 F! OFFICE 106 F1 (E) 13 13 F1 (E) i F1 (E), 13/Sb it S70 1; F1 (E) i',3/S8 liWORKSTATION I F1 (E) xip 15r 45 S. 4 F1 (E 15/S IMULTIPURPi I \ROOM! J F1 d 1 F1 -P 2 -F1 (E-)-21 -F4(E) -X -Y --X -X -X --X -x-X, t5/Sr @15 P" 1 FI(E)! F1 (E) MEN B1 LUNCH 125 1 15jS6 ROOM S6 F4(E) 1 !15 1, r FI(E) F1 (E) ZILV s% X 1 F7 17/ H3-113 1-7 17 M g,h.k, 17 TOOL SHOP Q EQUIPMENT F1 (E) I'll (E) Fl(E)i Fl(E) F1 (E) S10 OPEN 122 PI STORAGE 17h/S9 _17 S9 17h/ gL — -F' — ---- __�q — 17g/$9 15S9 ii it i i F1 (E) F1 (E) F1(E) !Fl(E) F1 (E) F7 F7 F7 17 1717 17 17 iii li 1 LV 71 1 B1 il lit it j 17k/S9 it 17m/S9 17k/S9 17m/S91, 17k/S9 it .1 171 1 1 F6 F6 S L 17/S9 17/S9 17/S9 17/S9 17/S9 j H3 -13/S10 H3 -13/S10 Fl-(E)-t3/S8 Fi( F1 (E) F1 (E) F1 (E) F1 (E) F1 (E) F7 S8 PRINT/17 17 17 tl COPY 17 ®X1(E) 13/S8 lit OR STORAGE 121 Ly V SHOWER F1 F1 F1 F1 li F1 (E) F1 (E) fi 1 F126 13 13 Ef3 13 F -3 M13 i 11 - --�= —JA—N. ij L�J`11 F7 OFFICE F1 (E) 113/S8..` 1 16 OFFICE OFFICE OFFICE .5 L H. 113 L 118 L120 J 15 FZ it 13 V SC====3 I F1 (E) 13 OFFICE F1 (E) 112 13 F1 (E) 13 ID OFFICE F1 (E) 13 I'll (E) 13 OFFICE F1 (E) 108 13 F! OFFICE 106 F1 (E) 13 13 F1 (E) i F1 (E), 13/Sb it S70 1; F1 (E) i',3/S8 liWORKSTATION I F1 (E) xip 15r 45 S. 4 F1 (E 15/S IMULTIPURPi I \ROOM! J F1 d 1 F1 -P 2 -F1 (E-)-21 -F4(E) Drawn By: @ 15 15/S6 15/S6 B1 1h FI(E) F1 (E) 15/'S6 1 1 S6 t5/Sr @15 F1 (E) F1 (E)i S5 L15/S5 15 614& 15/S5 F1 (E) am 5/ F1 (E) -S5 Xi 1—-5/-S5 15 F1 (E) F1 F1 4 LARGE 4 CONFERENCE El (E F1 F1 4 4 4 1 OFFICE OFFICE :L 1:17 HALL l.l 1117--V 104 1 F1 (E) 5/S3 4 S 113 OFFICE F1 (E) F1 15, 4 i OFFICE 13 Vs F1 (E) S3 1-3 B1 X1 (E) 4 15 \F1(E)15 RECEPTION F1 (E) 15f/S3 i 4 F51 i OFFICE '45' elf I/ - e ;155.3 15e/§: q F4 4/S2 F1 '111 5/S5 F1 4 4 F1 F1 4 OFfICEi OFFICE F-134 F4(E) 15@ F4(E) 15@ WOMEN 127 F4(E) 15@ F4 4/S2 B1 F1 4 4/S2 4/S2 sysl SERVER/E TOR 1IBRY S2 (E) 1 0 PLOTTER130 I El 4 0,4.4 X1 F1 (E) F1 (E) F1 (E) F1 (E) F1 (E) JF— SVS 4/S1.1 4/S7 4/S1 4/S1 4/S1 0131E 4 F1 (E) FI(E) F (E) 110 11 S F1 F1(E);, 4 , Fq 11 H 4/S1 4/Si qI it I 4/Sl 4/ VS it OPEN vp OFFICE 4 ii 4 OM it r 138 F1 (E) 14 n" I F,,* I (E) FI(E) 1 i OFFICE F1 B1 4%;S1(E) B 1 PH Si t 4 tzl 4d S1 4e,1/4f/S1F1 (E) 4f/Si 4 -A- -71 !SVS 4e/S1 F1 (E) 1'1(E) P1 (E) Ft (E) IG 14 Ad-- OFFIC F1 (E) F1 (E) F1 (E) 4a/S1 46/S1 46/S1 4a/S1 1334 ii a [>�5a.b,c, 4b/S1 4a 4b d,e,f II LIGHTING FLOOR PLAN SCALE: 1/8" = 1'-0" 10 F6 F6 H3-13/SlO H3 -13/S10 S10 ii' FISII F6 'S1O H3 -13/S10 F6 F6 H3 -13/S10 ii H3 -13(S10 F6 1 If F6 q,r q,r H3 -13/S10 H3-13/Sl 0 9 Sit F6 F6 --m ------- - --- n,p n,p H3 -13/S10 ji H3 -15/S10 '@n,p.q,r H3-13 Ill REVIEWED FOR COMPLIANCE tAv!T H NFPA 70 - NEC SEP 13 2016 City of-Tw(wile -- BUILDING DIVISICIN!, TITAN ELECTRIC FULL SERVICE ELECTRICAL CONTACTOR 12828 NORTHUP WAY, SUITE 205 BELLEVUE, WA 98005 PH: 425-250-2581 FA: 206-374-2128 19515 North Creek Parkway, Suite 302 Bothell, Washington 98011 Phone: 425-402-9400 Fax: 425-402-9402 Project Title: Tenant Improvement for: NW Hydraulics Designed By: TN Drawn By: BY Project No: F4(E) Date: ii 15/'S6 1 1 S6 t5/Sr @15 P" 1 FI(E)! F1 (E) MEN B1 LUNCH 125 1 15jS6 ROOM S6 F4(E) 1 !15 1, r FI(E) F1 (E) F1 (E) F1 (E)i S5 L15/S5 15 614& 15/S5 F1 (E) am 5/ F1 (E) -S5 Xi 1—-5/-S5 15 F1 (E) F1 F1 4 LARGE 4 CONFERENCE El (E F1 F1 4 4 4 1 OFFICE OFFICE :L 1:17 HALL l.l 1117--V 104 1 F1 (E) 5/S3 4 S 113 OFFICE F1 (E) F1 15, 4 i OFFICE 13 Vs F1 (E) S3 1-3 B1 X1 (E) 4 15 \F1(E)15 RECEPTION F1 (E) 15f/S3 i 4 F51 i OFFICE '45' elf I/ - e ;155.3 15e/§: q F4 4/S2 F1 '111 5/S5 F1 4 4 F1 F1 4 OFfICEi OFFICE F-134 F4(E) 15@ F4(E) 15@ WOMEN 127 F4(E) 15@ F4 4/S2 B1 F1 4 4/S2 4/S2 sysl SERVER/E TOR 1IBRY S2 (E) 1 0 PLOTTER130 I El 4 0,4.4 X1 F1 (E) F1 (E) F1 (E) F1 (E) F1 (E) JF— SVS 4/S1.1 4/S7 4/S1 4/S1 4/S1 0131E 4 F1 (E) FI(E) F (E) 110 11 S F1 F1(E);, 4 , Fq 11 H 4/S1 4/Si qI it I 4/Sl 4/ VS it OPEN vp OFFICE 4 ii 4 OM it r 138 F1 (E) 14 n" I F,,* I (E) FI(E) 1 i OFFICE F1 B1 4%;S1(E) B 1 PH Si t 4 tzl 4d S1 4e,1/4f/S1F1 (E) 4f/Si 4 -A- -71 !SVS 4e/S1 F1 (E) 1'1(E) P1 (E) Ft (E) IG 14 Ad-- OFFIC F1 (E) F1 (E) F1 (E) 4a/S1 46/S1 46/S1 4a/S1 1334 ii a [>�5a.b,c, 4b/S1 4a 4b d,e,f II LIGHTING FLOOR PLAN SCALE: 1/8" = 1'-0" 10 F6 F6 H3-13/SlO H3 -13/S10 S10 ii' FISII F6 'S1O H3 -13/S10 F6 F6 H3 -13/S10 ii H3 -13(S10 F6 1 If F6 q,r q,r H3 -13/S10 H3-13/Sl 0 9 Sit F6 F6 --m ------- - --- n,p n,p H3 -13/S10 ji H3 -15/S10 '@n,p.q,r H3-13 Ill REVIEWED FOR COMPLIANCE tAv!T H NFPA 70 - NEC SEP 13 2016 City of-Tw(wile -- BUILDING DIVISICIN!, TITAN ELECTRIC FULL SERVICE ELECTRICAL CONTACTOR 12828 NORTHUP WAY, SUITE 205 BELLEVUE, WA 98005 PH: 425-250-2581 FA: 206-374-2128 19515 North Creek Parkway, Suite 302 Bothell, Washington 98011 Phone: 425-402-9400 Fax: 425-402-9402 Project Title: Tenant Improvement for: NW Hydraulics Designed By: TN Drawn By: BY Project No: 16229 Date: 09/07/2016 �- 15e/S: Calculation Summary Label CalcType Units Avg Max Min Avg/Min Max/Min EMERGENCY EGRESS PATHWAY OFFICE Illuminance Fc 1.18 5.2 0.2 5.90 26.00 LAB EGRESS PATHWAY Illuminance Fc 1.01 5.4 0.2 5.05 27.00 STORAGE EGRESS PATHWAY Illuminance Fc 1.44 4.7 0.2 7.20 23.50 LIGHTING EGRESS CALCULATIONS SCALE: 1/8" = 1'-0" Im -X- X -X -X -X -X -X l v ,x TITAN ELECTRIC FULL SERVICE ELECTRICAL CONTACTOR 12828 NORTHUP WAY, SUITE 205 BELLEVUE, WA 98005 PH: 425-250-2581 FA: 206-374-2128 11h, CASE N ENGINEERING Consulting Electrical Engineers 19515 North Creek Parkway, Suite 302 Bothell, Washington 98011 Phone: 425-402-9400 Fax: 425-402-9402 Project Title: Tenant Improvement for: N W Hydraulics - REVIEWED FOR Gateway Corp. Ctr. Bldg 6 COMPLIANCE WIT H 12787 Gateway Dr. NPPA 70 - N117-0 Tukwila WA 98168 SEP 13 2016 Sheet Title: City Of TUkWW1lP, RECEIVED CITY OF TUKWILA SEP 07 2016 PERMIT CENTER LIGHTING EGRESS CALCULATIONS Designed By: TN Drawn By: BY Project No: 16229 Date: 09/07/2016 Sheet Number: L2 0A LIGHTING FIXTURE SCHEDULE Project Title: NW HYDRAULICS Date 8/25/2016 Compliance forms do not WATTS/ TYPE DESCRIPTION LAMP FIXT Company Address: 19515 N. CREEK PKWAY SUITE 302 BOTHELL, WA INTERIOR M Ail C405.2.1- C405.2,8 Controls (' C405.2 Exception 5 Luminaire Level Applicant Name: STEPHANIE ENLOW F1 EXISTING OR RELOCATED BUILDING STANDARD FLUORESCENT 2x4 2-F32T8 62 Project Description TROFFER. To comply vith C406.4, no less than 90% of the total installed interior lighting power shall comply 111th Include PROD -SUM form (included in envelope forms wrkbook) Wth lighting complliance forms. F2 RECESSED 2x2 LED TROFFER LED 18 F3 NOT USED. Refer to Section C502.2.6 for addition., requirements. Lighting systems in addition are combined with existing i building lighting systems to demonstrate compliance 13 F4 RECESSED COMPACT FLUORESCENT DOWNLIGHT 2-CFQ13 29 F5 DECORATIVE LED PENDANT LED 10 F6 PENDANT MOUNTED FLUORESCENT HIGH BAY TO MATCH EXISTING. 4-F32T8 124 F7 FLUORESCENT STRIP FIXTURE. 2-F32T8 62 X1 EXIT SIGN UNIVERSAL MOUNT WITH GREEN STENCIL FACE AND LED 5 of the retrofit project If project includes combination of spaces tlhere less than 50% of the existing fixtures are replaced INTEGRAL EMERGENCY BATTERY BACK UP. CRP CONTROL RELAY PANEL — — Lamp and/or ballast replacement only Q 1 13 -existing total wattage not increased 1 1 B1 EMERGENCY BATTERY PACK WiTH TWO ROTATABLE HIGH PERFORMANCE 2-3W LED 6 50% threshold applies to numberof luminaires for interiorspaces and parking garages, and total PATHWAY HEADS. 268 LUMENS PER HEAD. installed iiottage for exterior luminaires. requirements. 2015 Washington State Energy including R2, R3, R4 over 3 stories Project Info Project Title: NW HYDRAULICS Date 8/25/2016 Compliance forms do not Applicant Information. Provide contact information for individual uho can respond to inquiries about compliance form information provided. For Building Department Use - Company Name: CASE ENGINEERING require a password to Allowance Method Company Address: 19515 N. CREEK PKWAY SUITE 302 BOTHELL, WA use. Instructional and calculatingcelis are vrfte- protected. M Ail C405.2.1- C405.2,8 Controls (' C405.2 Exception 5 Luminaire Level Applicant Name: STEPHANIE ENLOW Applicant Phone: 425402-9400 EXT 16 Applicant Email: STEPHANiEr@CASEENG.COM r] Additional Efficiency Package Option 744 Project Description EI New Building Q Addition EaAlteration 0 Plans Included To comply vith C406.4, no less than 90% of the total installed interior lighting power shall comply 111th Include PROD -SUM form (included in envelope forms wrkbook) Wth lighting complliance forms. Building Additions Compliance Method I Interior lighting Exterior fighting Lighting Lighting systems in addition area comply with all applicable 1 fl provisions as a stand alone new construction project 13 Refer to Section C502.2.6 for addition., requirements. Lighting systems in addition are combined with existing i building lighting systems to demonstrate compliance 13 D Addition is combined with existing: IQ DUPLE( RECEPTACLE Description Forinterfor lighting projects, include new + existing interior lighting fixture voltage in Proposed (� DOUBL= DUPLEX RECEPTACLE Lighting Wattage table in LTG -INT -BLD orLTG-INT SPACE form, C CONDUIT Forexterior fighting projects, include new + existing exterior lightingfixture tlattage in Proposed ® RECESSED LINEAR FIXTURE Tradable and Proposed Non -Tradable Lighting Wattage tables in LTG -EXT form. Interior and Exterior Lighting Power I Interior lighting i Parking garage Exterior lighting o 50 /o or more of existing are replaced 1 13 1 ❑ Q Li htin Alterations ' g g Select all Lighting Polder and Lighting Control elements that apply to the scope ; I Less than 50% of existing are replaced!� � Q 13 of the retrofit project If project includes combination of spaces tlhere less than 50% of the existing fixtures are replaced RECESSED WALLWASHER CRP CONTROL RELAY PANEL — — Lamp and/or ballast replacement only Q 1 13 -existing total wattage not increased 1 1 13 in some spaces, and 50'A ormore of the fixtures are replaced in others, then provide separate lighting hover compliance forms for the 14to retrofit conditions. Spaces undergoing the same type of retrofit may be combined into one fighting potter compliance form. 50% or more replaced - Total lighting potter of new+ existing -to -remain fixtures shallcomply ttith total LPA per Sections C405.4.2 and C405.5.2. include new + existing -to -remain fixtures in Proposed Lighting Wattage table in LTG -INT -BLD, LTG 4NT--SPACE or LTG -EXT form. Less than 50% replaced - Total fighting pomr of new + existing -to -remain fixtures shall not exceed the total lighting pover prior to alteration. include new + existing -to -remain fixtures in the Proposed Lighting Wattage table in LTG -INT -BLD, LTG -INT -SPACE or LTG -EXT form. ©@) RECESSED EMERGENCY EGRESS DOWNUGHT 50% threshold applies to numberof luminaires for interiorspaces and parking garages, and total Refer to Section C503.6 for additional installed iiottage for exterior luminaires. requirements. Lighting Controls i interior lighting I Parking garage Exterior lighting All alteration lighting controls shall be commissioned perC408.3. New wiring installed to serve added ( I fixtures and/or fixtures relocated to i © 13 DISP DISPOSER new circuit(s) ® EM DIRECTIONAL EXIT SIGN (ARROWS INDICATE ONE OR TWO SIDES i New ormoved lighting pane! Ei EI I � Q DF DRINKING FOUNTAIN Interior space is reconfigured - luminaires unchanged or relocated i 1 New wiring orcircuit - For interiorlighting, provide required manual controls perC405.2.3, DOUBLE DUPLEX GFCI RECEPTACLE MOUNTED +4"O.C. ABOVE occupancysensorcontrols per C405.2.1, daylight responsive controls per C405.2.4 and application r3No changes are being made to the interior or exterior lighting systems and existing space uses and configuration are not changed. specific lighting controls per C405.2.5. For exterior lighting, provide required controls per C405.2.Z New ormoved panel - Provide all applicable lighting controls as noted for New tiring and automatic lime witch controls per C405.2.2. Reconfigured interior space - Provide all required lighting controls that apply to a new Interior space. Application specific lighting control provisions per 0405.2.5 do not apply to reconfigured Change of Space Use Q Existing interior lighting systems in areas under -going a change in space use are upgraded to comply with LPAs for the new space types per Tables C405.4.2(1) or C405.4.2(2). Identify interiorspaces requiring LPD upgrade to the current Code in Proposed Lighting Wattage WP Fable in LTG -INT -BLD or LTG-INT=SPACE form. 2015 Forms for over 3 stories and all R1 Revised July Project Title: NW HYDRAULICS Date 8/25/2016 Interior Lighting System Q C Addition - O Addition standalone +existinCJ ® Spaces where< 50%of O Spares where.�50%of C luminaires are replaced lurrdnaires are replaced Description LPA Calculation Type Interior Lighting Power 13 Building Area Method ® Spare -by -space Method Allowance Method Selectmethod used in project Interior Lighting Controls M Ail C405.2.1- C405.2,8 Controls (' C405.2 Exception 5 Luminaire Level 40 Lighting Control (LH C) 1488 1 r] Additional Efficiency Package Option 744 C406.4 Enhanced digital fighting controls AFF ABOVE FINISHED FLOOR To comply vith C406.4, no less than 90% of the total installed interior lighting power shall comply 111th required controls per C406.4. Dwelling Unit Interior Permanently installedinteriorlighting fixtures in dwiling units complyxith: Lighting 0 C405.2thru C405.5 Commercial Lighting Controls and LPA 9976 0 C406.3 High Efficacy Lighting 0 Exterior Lighting System IQ DUPLE( RECEPTACLE Description BKR BREAKER 2015Washington State Energy Code Compliance Forms for commercial Buildings including R2. R3. R4 over 3 stories and all R1 ReHsed July 2016 Project Title: NW HYDRAULICS Date 8/25/2016 Calcination Area NOTE Q C Addition - O Addition standalone +existinCJ ® Spaces where< 50%of O Spares where.�50%of C luminaires are replaced lurrdnaires are replaced For Building Department Use .- _._.._ � LPA Calculation Type 0 Standard 0 Additional Efi'idencyPackage Option 0 C406.3 Reduced Interior Lighting To comply with C406.3, the Proposed LPD shall be 25% lower than the Target LPA. Refer to 0406.3 faraddilional requirements. Maximum Allowed Lighting Wattage"O7E' NOTE: LIGHTING FIXTURE SYMBOLS SHOW LENGTH, Location (plan #, Height' Gross Interior room 9) Space Type 2 Area in fe Allowed Watts Allowed Watts per ft (v.mttsift2 x area) F5 -DECORATIVE LED PENDANT 4 10 40 F6 -PENDANT MTD FLUOR HiGH BAY -4 LAMP 12 124 1488 1 F7 -CHAIN MTD FLUOR STRIP -2 LAMP 12 62 744 SCHEDULE FOR LAMP TYPE & OTHER FIXTURE SPECIFICS. AFF ABOVE FINISHED FLOOR AHJ AUTHORITY HAVING JURISDICTION POWER RECEPTACLES &OUTLETS Total Area Retail Display Allowance from LTG -INT -DISPLAY Enter Total F.:dstmg Lighting Watts (prior to Alteration) 15046 I Lobby Art/Exhibit Display Allowance from LTG -INT -DISPLAY NOTc 8 L� Proposed Lighting Wattage"' Allovded Watts] 15046 I Location (plan #,- - Number of Wattst 6 5, room #) Fixture Description NOTE 4, Fixtures FiNOTE 7 xture I Watts j Proposed 1 F1 -EXIST OR RELOCATED 2x4 FLUOR TROFFER -2 119 62 7378 F2 -RECESSED 2X2 LED TROFFER 2 18 36 F3 -NOT USED NOTE: LIGHTING FIXTURE SYMBOLS SHOW LENGTH, 174 -RECESSED CFL DNLT-1 LAMP 10 29 290 F5 -DECORATIVE LED PENDANT 4 10 40 F6 -PENDANT MTD FLUOR HiGH BAY -4 LAMP 12 124 1488 1 F7 -CHAIN MTD FLUOR STRIP -2 LAMP 12 62 744 SCHEDULE FOR LAMP TYPE & OTHER FIXTURE SPECIFICS. AFF ABOVE FINISHED FLOOR AHJ AUTHORITY HAVING JURISDICTION POWER RECEPTACLES &OUTLETS Proposed Retail Display Lighting from LTG-INT-DiSPLAY Total Proposed Wattsmaynotexceed TotaiAllowedWatts for Interior Lighting Total Proposed Watts 9976 Interior Lighting Power Allowance COMPLIES Note 1- List all unique space types perTable C405.4.2(2) thatoccurin the project scope. Selectspace type categoyper iron drop down menu. Note 2 - indicate coffing height foratriums and spaces utilizing the ceiling height adjustment per Table C40a 4.2(2), Footnotes d thru f. Note 3 - List all proposed lighting fixtures including exempt lighting equipment and existing -to -remain fixtures. Note 4-ForproposedFixture Description, indicate fixture type, lamp type e9 T-��numberoflamps in the fixture, and ballast type lifincludedi. For track lighting, list the length of the track (in feet) in addition to the fixture, lamp, and ballast infomlatiah. Note 5 - Forlighting equipment eligible for exemption perC405.4.1, note exception numberandleave WatI&Fixture blarnk. Note 6 - Existing -lo -remain fixtures shah be included in the Proposed Lighting Wattage table in the same manner as new fixtures. identify as existing in fixture description Note 7 - For proposed WaffsIFIxtureenter the luminaire wattage forinstalted lamp and ballast usingmanufactureror other approved source. For luminaires with screw-in lamps, enterthe manufacturer's fisted maximum input wattage of the fixture (not the lamp grattage). For low voltage lighting, enter the wattage of the transformer. Forline voltage tradvbusway system4 enter the larger of the attached luminalre wattage or 50 wattaNneal foot, or enter the wattage limit of pemmrlent current limiting device. /dote 8 - LobbyArtExhibitDisplayAflowance Is independent of the Maximum Allowed Lighting Wattage. Note 9 - Calculation Area Details: a. Lighting fixtures in a building addition maycompfy as a stand alone project, ortheymay be combined with the overall existing building lighting systems to demonstrate compliance. Referto C502.1. ELECTRICAL SYMBOLS & ABBREVIATIONS LEGEND NOTE: ALL FIXTURES AND EQUIPMENT SHOWN ON PLANS IN STANDARD LIGHT FIXTURES & CONTROLS ABBREVIATIONS (HEAVY) LINE WEIGHT ARE NEW OR RELOCATED WORK. FIXTURES AND EQUIPMENT SHDWN IN LIGHT UNE WEIGHT WITH (E) NEXT TO THEM NOTE: LIGHTING FIXTURE SYMBOLS SHOW LENGTH, A (200A) (AFTER A NUMBER) = AMPS INDICATE EXISTNG TO REMAIN. SYMBOLS SHOWN AS DASHED INDICATE MOUNTING & EMERGENCY EGRESS INFORMATION ONLY. AF(200AF) (AFTER ANUMBER) =FUSE SIZE IN AMPS ITEMS TO BE REMOVED OR DEMOLISHED. THIS APPLIES UNLESS NOTED REFER TO FIXTURE DESIGNATIONS & LIGHTING FIXTURE OTHERWISE ON PLANS. SCHEDULE FOR LAMP TYPE & OTHER FIXTURE SPECIFICS. AFF ABOVE FINISHED FLOOR AHJ AUTHORITY HAVING JURISDICTION POWER RECEPTACLES &OUTLETS AL ALUMINUM O RECESSED DOWNLIGHT (ROUND) ATS AUTOMATIC TRANSFER SWITCH IQ DUPLE( RECEPTACLE ; PENDANT MOUNTED DOWNLIGHT BKR BREAKER (� DOUBL= DUPLEX RECEPTACLE ® SURFACE MOUNTED LINEAR FIXTURE C CONDUIT I1@1 DUPLE( GFCI RECEPTACLE ® RECESSED LINEAR FIXTURE CKT CIRCUIT DOUBLE DUPLEX GFCI RECEPTACLE ® PENDANT MOUNTED LINEAR FIXTURE CL CENTERLINE DUPLE:( RECEPTACLE MOUNTED IN CEILING ® SURFACE MOUNTED LINEAR FIXTURE (NARROW BODY) CLG CEILING �@USB DUPLE:( RECEPTACLE WITH 1/2 USB RECESSED LINEAR WALLWASHER C.O. CONDUIT ONLY k� DUPLE( RECEPTACLE MOUNTED +4"O.C. ABOVE COUNTER RECESSED WALLWASHER CRP CONTROL RELAY PANEL OR BACKSPLASH, WHEN PRESENT (U.O.N.) CU COPPER ©@) RECESSED EMERGENCY EGRESS DOWNUGHT DOUBLE DUPLEX RECEPTACLE MOUNTED +4"O.C. ABOVE ® UNIVERSAL/CEILING MOUNTED EXIT SIGN DIA DIAMETER COUNTER OR BACKSPLASH, WHEN PRESENT (U.O.N.) DISC DISCONNECT UP WALL MOUNTED EXIT SIGN DISP DISPOSER DUPLE( GFCI RECEPTACLE MOUNTED +4"O.C. ABOVE ® EM DIRECTIONAL EXIT SIGN (ARROWS INDICATE ONE OR TWO SIDES COUNTER OR BACKSPLASH, WHEN PRESENT (U.O.N.) DF DRINKING FOUNTAIN AND DIRECTION INDICATED) DOUBLE DUPLEX GFCI RECEPTACLE MOUNTED +4"O.C. ABOVE DW DISHWASHER COUNTER OR BACKSPLASH, WHEN PRESENT (U.O.N.) LIGHTING CONTROLS E.C. ELECTRICAL CONTRACTOR GFCI FECEPTACLE WITH WEATHERPROOF WHILE—IN—USE COVER ECB ENCLOSED CIRCUIT BREAKER WP a SINGLE POLE LIGHT SWITCH (E) EXISTING (USED AS SYMBOL DESIGNATION) DS 2 (LOWER CASE SUBSCRIPT DEFINES LIGHTS THAT ARE TO BE FLUSH FLOOR OUTLET BOX WITH DEVICES SHOWN A SWITCHED—MATCH WITH LETTERS AT FIXTURE) EMT ELECTRICAL METALLIC TUBING SWITCF'ED DUPLEX RECEPTACLE VIA CLOSEST OCCUPANCY S3 THREE POLE LIGHT SWITCH EXTG EXISTING (USED AS ABBREVIATION IN TEXT) � SENSOR FAAP FIRE ALARM ANNUNCIATOR PANEL DOUBLE DUPLEX RECEPTACLE WITH 1/2 SWITCHED VIA S DIMMER SWITCH FACP FIRE ALARM CONTROL PANEL OCCUFANCY SENSOR S OCCUPANCY SENSOR LIGHT SWITCH (NUMBER DEFINES RELAY I® SPECIAL PURPOSE RECEPTACLE NUMBER IN LIGHTING CONTROL PANEL–SEE SCHEDULE) FLR FLOOR SINGLE F.O.I.C. FURNISHED BY OTHERS, INSTALLED OJ JUNCTON BOX WITH BLANK COVER S VACANCY SENSOR LIGHT SWITCH BY ELECTRICAL CONTRACTOR LV LOW VOLTAGE, b = AREA TO BE CONTROLLED, GFCI GROUND FAULT CIRCUIT INTERRUPTER bet R# RELAY IN LIGHTING CONTROL PANEL S# SENSOR ZONE GND GROUND CONDUITS AND CIRCUITING KVA 1000 VOLT AMPERES © CEILING MOUNTED VACANCY SENSOR KW 1000 WATTS WIPING LOCATED IN CEILING OR WALL ® VACANCY SENSOR/PHOTO SENSOR LCP LIGHTING CONTROL PANEL – — — – WIPING CONCEALED UNDER FLOOR OR UNDERGROUND os CEILING MOUNTED OCCUPANCY SENSOR LT LIGHT �– CONDUIT HOME–RUN o ® PHOTOCELL LIGHT SENSOR LTS(LTG LIGHTS LIGHTING � (LIGHTING) ��lfr SLASHES ACROSS CONDUIT INDICATE NUMBER OF WIRES LV LOW VOLTAGE WITHIN — SHORT = HOT, LONG = NEUTRAL MCB MAIN CIRCUIT BREAKER AUDIO/VISUAL DEVICES SERVICE GEAR - AS SHOWN ON PLANS MECH MECHANICAL MLO MAIN LUGS ONLY ❑Q TELEV13ION (RG6 COAX) CIRCUIT BREAKER PANELBOARD N3R NEMA 3R LOAD CENTER NIC NOT IN CONTRACT TELE/COMMUNICATIONS SYSTEM DEVICES T DRY TYPE TRANSFORMER (SEE NOTES & RISER OS OCCUPANCY SENSOR ®W WALL MOUNTED TELEPHONE (VERIFY MOUNTING HEIGHT) DIAGRAM FOR SIZE) PC PHOTOCELL ® SINGLE GANG TELEPHONE/DATA OPENING PNL PANELBOARD Q WAP WIRELESS ACCESS POINT NOTES AND MISCELLANEOUS SYMBOLS PSE PUGET SOUND ENERGY PUD PUBLIC UTiUTY DISTRICT SECURITY SYSTEM EQUIPMENTF: FLAGNOTE – IDENTIFIES A SPECIFIC ITEM ON A DRAWING. REC RECEPTACLE(S) COORESPONDS TO A SCHEDULE IN THE ELECTRICAL SET THAT NOTE: COORDINATE RACEWAY REQUIREMENTS WITH SECURITY VENDOR. EXPLAINS DETAILS OR FEATURES OF THAT ITEM. REF REFRIGERATOR (R) RELOCATED EXISTING cR CARD READER ACCESS OUTLET FF -3 MECHANICAL FLAG – DEFINES MECHANICAL EQUIPMENT AND SCL SEATTLE CITY LIGHT D COORESPONDS TO DESIGNATIONS IN MECHANICAL PLANS AND VIDEO INTERCOM SCHEDULES. COORESPONDS MECHANICAL CONNECTION SCHEDULE SNOPUD SNOHOMISH PUBLIC UTILITY DISTRICT Do DOOR OPENER IN THE ELECTRICAL SET. SW SWITCH DQ SECURTY CAMERA 200 EQUIPMENT FLAG – DEFINES SPECIAL (IE: COOKING) EQUIPMENT TBD TO BE DETERMINED ON A PLAN AND COORESPONDS TO DESIGNATIONS IN AN TTB TELEPHONE TERMINAL BOARD EQUIPMENT CONNECTIONS & CONTROLS EQUIPMENT SCHEDULE IN THE ELECTRICAL SET. TYP TYPICAL REVIEWED F OR ® EQUIPMENT CONNECTION REVISION CLOUD AND FLAG CLOUD SURROUNDS INFORMATION - U.O.N. UNLESS OTHERWISE NOTED EQUIPMENT THAT HAS BEEN REVISED. FLAG IDENTIFIES THE REVISION IN VM VARIABLE FREQUENCY DRIVE COMPLIANCE WITH WALL MOUNTED CONNECTION 1 WHICH THE CHANGES WERE MADE. NFPA 70 - NEC I� MOTOR CONNECTION VS VACANCY SENSOR WAP WIRELESS ACCESS POINT FAN CONNECTION SEP 13 2016 W/0 WITHOUT Su MOTOR RATED SWITCH WP WEATHERPROOF (l PADDLE FAN XFMR TRANSFORMER City of Tukwila BUDDING DIVISION REVISIONS FNonces shad be m o"k t^�itha>� 'd� to the scope P'7or P-40prov t;Lf?,tdin Divi toilDi of;:tr,5a,3 Lill r�q(,rire a R,�tt/. . f and may ire'odL add',tianat L � an submittal pian revie��.► fees. E� 1 ", IE A PERs1iT UE"J FOR. 01f."No'chanieW Electrical 23TIumbing MoGa.S PI Cli",+ of Tulwwla Permit Ala. Plan rov1,9W a royA AP 1 is subject to errors and 0missiors. Approval sof cOnsiriiction documents does not au'lhorize the violation of any adopted cede or Ordinance. R-cceipf Of approvad ield Copy and conditions is acknO%Iedged: [IV: CRY sof Tu la BUILDING DIV1,S1011 '•Uelff D514 EO.1 ELECTRICAL LEGEND & SCHEDULES EO.2 RISER DIAGRAM & SCHEDULES EO.3 PANEL SCHEDULES E1.1 POWER & COMMUNICATIONS FLOOR PLANS E2.1 LIGHTING FLOOR PLAN EL2.1 LIGHTING EGRESS CALCULATION TITAN ELECTPJC FULL SERVICE ELECTRICAL CONTACTOR 12828 NORTHUP WAY, SUITE 205 BELLEVUE, WA 98005 PH: 425-250-2581 FA: 206-374-2128 CA�) ENGINEERING Consulting Electrical Engineers 19515 North Creek Parkway, Suite 302 Bothell, Washington 98011 Phone: 425-402-9400 Fax: 425-402-9402 Project Title: Tenant Improvement for: NW Hydraulics Gateway Corp. Ctr. Bldg 6 12787 Gateway Dr. Tukwila, WA 98168 Sheet Title: ELECTRICAL LEGEND AND SCHEDULES RECEIVED Designed By: CITY OF TUKWILA Drawn By: SEP 07 2016 PERMIT CENTER Project No: Date: Sheet Number: TN BY 16229 09/07/2016 PKII 1888W 48GY/ 1000 SEATTLE CITY 1000 LIGHT M M Il,OOAC cm 3 r'�J 200A BUSSED I GUTTER RISER DIAGRAM NOT TO SCALE LEGEND NOTES 200 EXISTING FEEDER SIZE IN AMPS EDSOLID SHADING IN HEAVY LINES INDICATES NEW WORK IN THIS CONTRACT. PARTIAL SHADING IN LIGHT LINES INDICATES LJ EXISTING EQUIPMENT THAT HAS BEEN MODIFIED IN THIS CONTRACT. 32,500 AVAILABLE FAULT CURRENT (IN AMPS) 9 90 75 kVA 200 XFMR 2"C-4#3/0 CU & 1#6 CU GND 9,814 90 75 kVA 200 %I— XFMR 1 1/4-C-3#3 CU & 1#8 CU GND 4cVA 4,408 FIR%f 2"C-4#3/0 CU & 1#4 CU GND 1ST FLOOR #4 -REVIEWEE) FOR COMPLIANCE ?,"TI -1 NFPA 70 13 2016 CitY k vita` Mgt.. --- - _ TITAN ELECTRIC FULL SERVICE ELECTRICAL CONTACTOR 12828 NORTHUP WAY, SUITE 205 BELLEVUE, WA 98005 PH: 425-250-2581 FA: 206-374-2128 19515 North Creek Parkway, Suite 302 Bothell, Washington 98011 Phone: 425-402-9400 Fax: 425-402-9402 Hydraulics RISER DIAGRAM Designed By: TN Drawn By: BY Project No: 16229 Date: 09/07/2016 Sheet Number: PANEL H3 PROJECT NAME NW HYDRAULICS PROJECT #. 16229 LOCA710M FED FROM NOTE CKT NO. CIRCUIT NAME CB SIZE LOAD(1KVA) PANEL DESCRIPTION 0 AMF P R H M L K O TOTAL 24 52.8 1 PUMP A 40 3 € 7.6 PHASE B KVA : AMPS : 52.5 189.4 7.6 PANEL AMPS : 225 FEEDER AMPS : 200 L - L VOLTS : 480 -- 3 5 - ....................................................... - B - ..... ...... ....... C - - .... - i 7.6 ................................................. ;................ € 7.6 ................ ................ 7.6 .................. 7.6 9.9 7 PUMP 4 A 50 3 € 11.1: 44 - d2 - ................ ....................................... ..... - 11.1 L - N VOLTS : 277 PHASE: 3 LNPF : 4 11.0 a ....... ......... >............... ................................................ 8.2 9 11 - ..__�__.._...__.-._.-._-__..___.__..........................................................................., - B. C - ....................�...............�............,...;.....................,........................................,.. 11.1 0.4 A 20 .................... B 20 ..... C 20 11-1 CORD REEL COED t?E� CORD REEL 13 LTS- LAB A 20 1 € 1.5 15 1.9.. ....................................................................................................................... 21 1.5 M L.O. 15 -. 17 SPARE ....................................................................................................... SPARE B 20 C 20 1 1 ............... ....................................... ........... M.L.O. MAIN CB ..... 0.6 19 SPARE A 20 1 20DA 1 23 CORD REEL - - M L.O. MAIN CB FLUSH X 1.5 3 21 23 SPARE SPARE B 24 C.......1 1 .................................................................................................................. -- 25 CORD REIT _ A 20 1 25 SPACE A - 1 1 ................ 1.5 SURFACE X SURFACE X 27 CRDFO 27 29 SPACE SPACE B - C - 1 1.............................................................................................................. -- ................ 1,5 ISD. GND FEED-THRU ..... ............ ..... ................ ;................ ................ 31 33 SPACE SPACE A - R ....._........................................ 1 ............... ,................................................ rl ...... ............ x SPACE PUMPS SPARE SPARE SPARE SPARE 10.8 -- LOADSUMMARY SPACE SPACE- ( T:) -A-. AIL L SECT REID KVA : HEAT KVA : CUS' 29.1 10.8 10.8 1b.8 MOTOR KVA : 120.8 10.8 LIGHTING KVA : KITCHEN KVA 1.5 10.8 10.8 OTHER KVA : PHASEA KVA : 24 52.8 100% _ AMPS : 190.7 ......... PHASE B KVA : AMPS : 52.5 189.4 1 1 ......... PHASECKVA: A MPS -. 48.5 175.0 L LIGHTING -- 28 30 SPACE SPACE- B- C..............1...............................................;....................................... 1 € [ CIRCUIT NAME ....................... R RECEPTACLES - TO 1OKVA 100% = 10.0 32 SPACE A - 1 K H HEATING 100% _ CONNECTED LOAD M MOTORS 34 36 SPACE ...........................................................................................�................c................;..,...........................................,................... SPACE B - C - 1 1 125% = 41.6 PANEL AMPS : 225 L LIGHTING KVA : 153.8 AMPS: 185.0 = 1.9 38 PANEL R3 VIA 75KVA XFMR A 100 3 9.9 O OTHER 1.2 11.1 DEMAND LOAD -- 44 - d2 - ................ ....................................... ..... - B - .....-........................ C - 11.0 a ....... ......... >............... ................................................ 8.2 0.4 1.2 ...... 12.2 ... ....... 8.2 KVA : 152.9 AMPS : 183.9 NOTESIREMARKS : 1- DEM AND I DIV ERSITY FACTORS LOCATION: FED FROM: LOAD DESCRIPTION DEMAND CIRCUIT NAME 2. R RECEPTACLES - TO 1OKVA 100% = 10.0 3. REMAININ3OVER 10KVA 60% = 9.5 K H HEATING 100% _ 1 3 5 M MOTORS 100% = 87.6 1.3 ........................................... 1.3 € 1.3 LM LARGEST MOTOR 125% = 41.6 PANEL AMPS : 225 L LIGHTING 125% = 1.9 77 .............................................................................................................................................:..................................................------ 9 11 K KITCHEN 100% = 1.3 1.3 1.3 O OTHER 100% = 2.4 PANEL P-3 PROJECT NAME NW HYDRAULICS PROJECT it 16229 LOCATION: FED FROM: NOTE CKT NO. CIRCUIT NAME CB SIZE -AMP LOAD(KVA) PANEL DESCRIPTION $ P R H M L K O TOTAL ............................................................................................... 1 3 5 6-20R .................................................................................. 6 20R A 20 B - C 20 2 - 2 1.3 ........................................... 1.3 € 1.3 1.5 5.0 6.8 PANEL AMPS : 225 1.3 1.3 1.3 PANEL AMPS : 225 FEEDER A NPS : 200 L- L V OLTS : 208 L- NVOLTS : 120 PHASE: 3 WRE : 4 - 77 .............................................................................................................................................:..................................................------ 9 11 - 208 A - B 20 C - - 2 - 1.3 1.3 1.3 4.6 5.7 FEEDER AMPS : 200 L - L VOLTS : 480 L - N VOLTS : 277 PHASE : 3 WIRE : 4 1 ....:...................................... ................ H1.3 1.3 RTU -6 ........................................................................ ................... 13 REC- LAB A 20 11 0.4 ........ ................ 2.2 2.2 .................. 2.2 2 2 2 13 15 17 0.4 A 20 .................... B 20 ..... C 20 15 1 ! 19 CORD REEL COED t?E� CORD REEL BZO..........:5 C 20 ... ............ 20 1 ..... I 1 ............................................................_ 1.5 ................ >........................................................._ 1.5 2.0 1.6 1.6 1:2 15 1.9.. ....................................................................................................................... 21 1.5 1.5 1.5 M L.O. 1 21 CORD REEL B 20 1 1.51.5 M.L.O. MAIN CB 0.6 0.6 1MFiE : 4 23 WINCE FLUSH X 20DA 1 23 CORD REEL - - C 20 1 1.5 3 15 .......................................................................................................................................................... 25 27 1.5 -- 25 CORD REIT _ A 20 1 1.5 17 SURFACE 180 GND - ..................... 1 ................ 1.5 SURFACE X C - 1 27 CRDFO B 20 1 1.5 - FEED THRU -- ................ 1,5 ISO GND FEED-THRU ..... ............ ..... ................ ;................ ................ 29 SPARE C 20 1 •• rl MAIN CB x 200A 1,3 31 SPARE A 20 1 i ................ ................................................................................................................................ .................. ......................................>. .................................................................................. 1,3 33 SPARE B 20 1 _. -- -- ...................................... SURFACE X 1,3 1,3 35 SPARE C 20 1 2 SPARE A 20 1 110 GND FEED-THRU i f I -O TAL,ALL BEC -TOES 1 37 SPACE A - 1 6 20 1 RKY KVA : 9.0 3.3 2 FURNITURE FEED- OPEN OFFICE 117 LOAD SUM MARY - 3 SPACE - g - 1- : .._...~... _..-. :2- 2.2 -_. - -� 2.2 (TC TAL, ALL SEC-IOASI 10 41 SPACE C - 1 - - MOTOR KVA : 0.7 3 3 - ..................... KTfCF{EN KVA ................ REC KVA : 29.1 -12.2 2 6-20R A 20 2 1.3 1 C 2.2 OTHER KVA 13.7 1.2 r2.5 RTU -1 4 6 - 6-2DR B - C 20 - 2 1.3 1.3 0.2 1.3 2 1.2 2.5 1.3 HEAT KVA MOTOR KVA - 8 - A - - 1.3 PHASEA KVA : 25.5 C 18 - - 1.3 LIGHTING KVA 1.3 10 6-208 B 20 2 1.3 2,3 20 PUMP 5 50 1.3 KITCHEN KVA 1 0.7 1 0.7 11.1 PHASEB KVA : 27.2 MOTOR KVA 22 - B A 20 1.3 OTHER KVA : 2.4 - 14 6-20R A 20 2 1.3 •; - C - - 11.1 1.3 D.D. 16 - - - B - - - 1.3 SPACE 1 1 1 - ..................... ................. 1.3 PHASEA KVA : 11.1 AMPS ; 92.2 OTHER KVA . 13.7 PHASEA KVA : 6.8 18 SPARE C 20 1 SPACE B _ 1 0.2 ................ ................................. 0.9 AMPS : 56.5 PKIASEB _ KVA . 7 AMPS : 47.5 PHASECKVA 5.5 AMPS : 45.0 CONNECTED LOAD KVA : 18.0 ---- 20 SPARE - A 20 1 ( C _ 1 ............ 1,3 30 PHASE B KVA : 17-2 B 20 22 SPARE - B 20 1 '- - ..................... ................. AMPS : 101.7 24 SPARE C 20 1 _ ...................................... .................................................... ..................... --.... .............. .................PHASE C KVA : 8.2 AMPS . 68.3 26 SPARE A 20 1 _ AMP : 92.1 --- 28 -'SPARE SPARE B 20 1 R RECEPTACLES- TO 10KVA 100% = 4.3 REMAINING OVER 10KVA 50% _ H HEATING 1000/0 = M MOTORS 1009/0 = LM LARGEST MOTOR 1259/o _ L LIGHTING 125% _ K KITCHEN 1000/0 _ O OTHER 1000/0 = 13.7 DEMA ND LOA D KVA : 87.0 '"j0 C 20 1 - ..................... AMP : 104.6 ................. DEMAND DIVERSITY FACTORS LOAD DESCRIPTION DEMAND 32 SPACE Al CONNECTED LOAD 34 SPACE B - KVA . 31.5 AMPS : 87.3 DEMAND LOAD kVA : 21.9 AMPS 60.9 : ................................................................................................................................................. 36 38 SPADE SPACJ................................................................................................. G - A...................................... -......... ................................................__ .. ................ ............... .......... _._ -- 42 SPACE C _ NOTESIREMARKGS : 1. 2• 3• DEMAND/ DIVERSITY FACTORS LOAD DESCRIPTION DEMAND R RECEPTACLES - TO 10KVA 100% = 10.0 REMAINING OVER 10KVA 51)1% = 9.5 H HEATING 100% _ M MOTORS 100% _ LM LARGEST MOTOR 125% _ L LIGHTING 125% K KITCHEN 100% _ 0 OTHER 100% = 2.4 (E) PANEL H2 PROJECT NAME IWV HYDRAULICS PROJECTM 16229 LOCATION: FED FROM NOT CKf NO. CI RCUT NAME CB SIZE 16FAMP I LOAD(KVA) PANEL DESCRIPTION 8 AMP PI R I H I M L K 1 O TOTAL 1 1 75 KVA XFMR TO PANEL R2 A 90 31 1.8 1 1.5 1.5 5.0 6.8 PANEL AMPS : 225 ...............��..................................................................................................................... 3 - B - C ....._ - - 1.1 - .....1.4....:............ ......... 1.5 ................4.1..........x.5.... 4.6 5.7 FEEDER AMPS : 200 L - L VOLTS : 480 L - N VOLTS : 277 PHASE : 3 WIRE : 4 1 ....:...................................... ................ 7 .... 1.1...._............................................................................................. RTU -6 ........................................................................ ................... A 25 B . C................. - 3 - ......... ......... 2.2 .. :................... 2.2 .............................................................................. € 2.2 ......... ........ ........ ................ 2.2 2.2 .................. 2.2 2 2 2 13 15 17 LTS - NORTH .............................................................. ............................................... Ll8 -NORTH _........................................................ LTS - TRARISCRIFT ROOM .......... A 20 .................... B 20 ..... C 20 1 1 1.. ............. ....:................ ................ € € ................................................................................................ 2.D ..... ............................................................. 1.fi 1.6 1 FURNITURE FEED- OPEN OFFICE 138 B 20 2.0 1.6 1.6 1:2 15 1.9.. ....................................................................................................................... 21 SPACE SPACE A - . B ..............1 ' 1 ...............;...............,............... ............ .... ... ............................................... 1 MW- LUNCH ROOM 124 M.L.O. MAIN CB 0.6 0.6 1MFiE : 4 23 SPACE C - 1 1 20 1 0.4 0.6 0.6 FLUSH 3 15 .......................................................................................................................................................... 25 27 SPACE SPACE A _ g - 1 1 €€ ................:................:.................................................................................. 0.6 X 3 17 SURFACE 180 GND X 1 20 j 1 29 SPACE C - 1 3 19 FURNITURE FEED- OPEN OFFICE 138 A 20 1 FEED THRU 0.6 ................ ............ .................................................................................................................... ..... ............ ..... ................ ;................ ................ ............... ........ ........................................... 1 j ISO GND FEED THRU rl MAIN CB x 200A 1,3 23 SPARE C 20 1 ................ ................................................................................................................................ .................. ......................................>. .................................................................................. 1,3 25 SPARE -- - A 20 LOADSUMMARY f TDTn L.n__ SE=TIONE I I -- -- -- SURFACE X 1,3 1,3 27 29 SPARE SPARE - RLQ KVA : 4.3 2 2 SPARE A 20 1 110 GND FEED-THRU i f I -O TAL,ALL BEC -TOES 1 2 4 LTS - SOUTH 6 20 1 RKY KVA : 9.0 3.3 2 FURNITURE FEED- OPEN OFFICE 117 3.3 HEAT KVA MOTOR KVA 50.1 LIGHTING KVA : 8.4 - 1 6 -- 8 SPADE- -- RTAS_._..._.�_....._....._.._._._...__...�_. G - A 25 1 3 .._...~... _..-. :2- 2.2 -_. ._ -� 2.2 3 10 - B - 20:1 ; 2,2 ': - 0-7 MOTOR KVA : 0.7 3 3 2.2 KTfCF{EN KVA A B 12 -12.2 0.4 0.4 LIGHTING KVA KITCHEN KVA : 4.6 LOADSUMMARY 12 iREC- TOOL SHOP C 2.2 OTHER KVA 13.7 1 14 RTU -1 A 15 3 ? 1.3 - I - 0.2 0.2 1.3 2 16 - B - - I 1.3 2 FURNITURE FEED Al20 1.3 PHASEA KVA : 25.5 C 18 - - C - - 1.3 B 20 1 A 1.3 AMPS : 91.9 2,3 20 PUMP 5 50 3 - 11.1 1 0.7 1 0.7 11.1 PHASEB KVA : 27.2 MOTOR KVA 22 - B A 20 1"'--d.-21.1 I-- 26 28 0.4 0.5 AMPS : 98.4 3 Za - C - - 11.1 C ................... D.D. 1.1 11.1 PHASECKVA 23.8 12 14 16 26 SPACE 1 1 1 0.7 j ................>-.................................................................................. 0.5 0.4 ? 0.2 0.4 - 0. f 0.7 0.7 OTHER KVA . 13.7 PHASEA KVA : 6.8 3 1,3 .......................................................................................................................................................................................:................: 3 AMPS : 86.0 FSG- RATION 100 SPARE SPARE 28 SPACE B _ 1 0.2 ................ ................................. 0.9 AMPS : 56.5 PKIASEB _ KVA . 7 AMPS : 47.5 PHASECKVA 5.5 AMPS : 45.0 CONNECTED LOAD KVA : 18.0 1,3 1,3 1.3.......28...SPARE 24 26 SPARE SPARE .............................................................................................. B 20 C 20 A ...20....1.... 30 SPACE C _ 1 ............ 1,3 30 SPARE .................................................................................................................. B 20 1 ................. ................ ................................................................................................... ................ ................ ................ ................... '- CONNECTED LOAD - - - AMPS : 50.0 ...................................... .................................................... ..................... ............... ............... ................ ................ KVA : 76.5 ........ ........................... CEIVAND LOAD KVA : 18.0 - - - -- - _ AMP : 92.1 AMPS : 50.0 NOTESIREMARKS: 1. REMOVE EXISTING CBANDPROVIDE (1) NEW 20AI1P CEL Z EXISTING CIRCUIT, NO NEW LOAD. 3. NEW WORKS LOAD CHANGED. DEMANDI DIVERSITY FACTORS LOAD DESCRIPTION DE WAND R RECEPTACLES- TO 10KVA 100% = 4.3 REMAINING OVER 10KVA 50% _ H HEATING 1000/0 = M MOTORS 1009/0 = LM LARGEST MOTOR 1259/o _ L LIGHTING 125% _ K KITCHEN 1000/0 _ O OTHER 1000/0 = 13.7 DEMA ND LOA D KVA : 87.0 AMP : 104.6 NOTESIREMARKS: 1. EXISTING CIRCUIT, NONEW LOAD. 2. NEW WORK LOAD ADDED. 3. PROVIDE (1) NEW 5OA13P CB IN AVAILABLE SPACE DEMAND DIVERSITY FACTORS LOAD DESCRIPTION DEMAND R RECEPTACLES- TO 14KVA 100% = 4.3 REMAINING OVER 10KVA 50% H HEATING 1009/0 = M MOTORS 1DD9/o = 16.8 LM LARGEST MOTOR 125% = 41.6 L LIGHTING 1259/o = 10.6 K KITCHEN 100% = O OTHER 100% = 13.7 (E) PANEL P-2 PROJECT NAME NW HYDRAULICS PROJE33T#: 16229 LOCATION: FED FROM: NOTE CKT NO. CIRCU-NAME CBSIZE LOAD(KVA) PANEL DESCRIPTION 8 AMP P R H M L K O TOTAL 3 1 SERVER -SERVER 129 A 20 1 3.6 100% = 1.5 1.5 PANEL AMPS : 225 3 3 R -OTTER- PLOTTERROOM 103 B 20 1 8.1 A 1.5 1.5 F EEDER AMPS : 2DO L - L VOLTS : 208 L - N VOLTS : 120 3 5 PLOTTER - PLOTTER ROOM 103 C 20 1 ( `: I 0.7 1.5 1.5 3 7 RFC- PRNATEOFFICES 131, 132, 133 Al20 1 1.1 I 3 0.5 1.6 3 9 1 FURNITURE FEED- OPEN OFFICE 138 B 20 1 1:2 15 0.6 0.6 PHASE : 3 3 11 FURNITURE FE®- OPEN OFFICE 138 C 20 1 MW- LUNCH ROOM 124 C 0.6 0.6 1MFiE : 4 3 13 FURNITURE FEED- OPEN OFFICE 138 A 20 1 20 1 0.4 0.6 0.6 3 15 FURNITUFiE FEED- OPEN OFFICE 138 B 205 B 1 1.8 0.6 0.6 X 3 17 FURNITURE FEED- OPEN OFFICE 138 C 20 1 20 j 1 1.8 0.6 --- 0.6 3 19 FURNITURE FEED- OPEN OFFICE 138 A 20 1 20 11 0.6 0.6 M.L.O. 1:2 1 3 21 LTS - UC B 20 1 j ISO GND FEED THRU rl MAIN CB x 200A 1,3 23 SPARE C 20 1 FLUSH 1,3 25 SPARE -- - A 20 1 I -- -- -- SURFACE X 1,3 1,3 27 29 SPARE SPARE - B 20 C 20 1 1 i I i 110 GND FEED-THRU i f I -O TAL,ALL BEC -TOES 1 f I RKY KVA : 9.0 3 2 FURNITURE FEED- OPEN OFFICE 117 A 20 11 1.2 1.2 3 4 FORNn-uRE F®- OPEN OFFICE 117 B 21) 11 1.2 1.2 FEAT I{VA : 3.6 3 6 SW FURN. FE@- OPEN OFFICE 117 C 20:1 0.7 ': - 0-7 MOTOR KVA : 0.7 3 3 8 10 RED- TOOL SHOP REC- TOOL SHOP -- A B 20 1 2D ; 1 0.4 0.4 0.4 0.4 LIGHTING KVA KITCHEN KVA : 4.6 LOADSUMMARY 12 iREC- TOOL SHOP C 20 20.2 -3- _ _ i 0.2 OTHER KVA : 8.1 1,2 14 rT]TAL.n__ SE=TIONE I A - I - 0.2 0.2 2 16 REF B REC KVA : 4.3 2 2 FURNITURE FEED Al20 1 ? C 1.2 1.2 2 4 FURNITURE F® B 20 1 A -.t-, 20 1 1.2 1.2 FEAT KVA 2 6 FURNITURE FEE) C 20 1 0.7 1 0.7 1.2 1.2 MOTOR KVA 3 8 REC- PRIVATEOFFICES 134,135 A 20 1"'--d.-21.1 I-- 26 28 0.4 0.5 LIGHTING KVA 3 10 REG- PRICe4TE OFFICES 135, 136 B 20 1 D.7 C ................... D.D. 1.1 KITCHEN KVA 3 3 .................................. 3 12 14 16 REC- LARGECONFERENCE 107 Ri C- FRNATEOFFICE103 .................................................................................... REC--PRKIATEOFFICE101, 102 C 20 A 20 ...... . B 20 1 1 1 0.7 j ................>-.................................................................................. 0.5 0.4 ? 0.2 0.4 - 0. f 0.7 0.7 OTHER KVA . 13.7 PHASEA KVA : 6.8 3 1,3 .......................................................................................................................................................................................:................: 3 18 20 22 FSG- RATION 100 SPARE SPARE G 20 A 20 B 20 1 1 1 0.7 ................................................................................... ............... ................. 0.2 ................ ................................. 0.9 AMPS : 56.5 PKIASEB _ KVA . 7 AMPS : 47.5 PHASECKVA 5.5 AMPS : 45.0 CONNECTED LOAD KVA : 18.0 1,3 1,3 1.3.......28...SPARE 24 26 SPARE SPARE .............................................................................................. B 20 C 20 A ...20....1.... 1 1 s .................................................................................................. ....>... ......... ......... ........ ........ ......... ............ 1,3 30 SPARE .................................................................................................................. B 20 1 ................. ................ ................................................................................................... ................ ................ ................ ................... AMPS : 50.0 ...................................... .................................................... ..................... ............... ............... ................ ................ ................ ........ ........................... CEIVAND LOAD KVA : 18.0 ' AMPS : 50.0 NOTESIREMARKS: 1. REMOVE EXISTING CBANDPROVIDE (1) NEW 20AI1P CEL Z EXISTING CIRCUIT, NO NEW LOAD. 3. NEW WORKS LOAD CHANGED. DEMANDI DIVERSITY FACTORS LOAD DESCRIPTION DE WAND R RECEPTACLES- TO 10KVA 100% = 4.3 REMAINING OVER 10KVA 50% _ H HEATING 1000/0 = M MOTORS 1009/0 = LM LARGEST MOTOR 1259/o _ L LIGHTING 125% _ K KITCHEN 1000/0 _ O OTHER 1000/0 = 13.7 PROJECT NAME LOCATION NOTE CKT NO. 1 1 75KVA 3 5 - 1 1 7 RTU -2 1 23 SPACE NW HYDRAULICS CIRCUIT NAME 7R -TO P-1 NOTESIRE4IARKS : 1. EXISTING CIRCUIT, NO NEW LOAD. 2 3. (E) PANEL H1 FED FROM: CB SIZE I LOAD(KVA) DAMP R I H M L K 4 90 31 2-5 1 ` 3 - - 3.4 1 1.8 j 1.E - - 3.1 € 1.8 0.7 € 3.( k 15 3 1.3 22 22 2.2 22 1.7 (i1b DEM AND I DIVERSITY FACTORS LOAD DESCRIPTION R RECEPTACLES - TO 10KVA 200 REMAINING OVER 10KVA H HEATING M MOTORS LM LARGEST MOTOR L LIGHTING K KITCHEN O OTHER PROJ MT #.' 16229 1 ?TALI PANEL DESCRIPTION 6.2 PANELAMPS : 225 9.5 FEEDERAMPS : 200 10.3 L - L VOLTS ; 480 1.3 L - N V OLTS : 277 13 PHASE: 3 1.3 WIRE ; 4 2 M.L.O. MAIN CB FLUSH SURFACE X ISO GND FEED-THRU INA : LOADSUMMARY I II I AI 41 I :1 1: RE3-- KVA : HEAT KVA : MOTOR KVA : LIGHTING KVA : KITCHEN KVA : OTHER KVA : PHASEA KVA : AMPS : PHASE B KVA : AMPS : PHASECKVA : AMPS : 1111.!: 1 9.0 3.6 22.7 4.6 8.1 13.5 48.8 16.9 60.9 17.6 63.6 57.7 EMA ND LO.A D CKT NO 22 2.2 2-2 1-7 1.7 1.7 - AM PI INA : 48.0 AMPS : 57.7 EMA ND LO.A D CKT NO KVA : 49.6 AMPS : 59.7 8 AM PI R H M L K 0 TOTAL DEMAND 1 100% = 9.0 500/0 = 0.5 100% = 3.6 100% = 16.2 125% = 8.1 125% = 1000A = 4.6 100"!0 = 8.1 REVIEWED OR COMPLIANCE WITH FPA 70 -ITEC SEP 13 2016 City of TukWila i 01111 nlKln nnnr%te._. r w�rw�■ w�A a.dl W IVIG Ji a (E) PANEL P-1 PROJECT NAME NW HYDRAULICS PROJMT #: 16229 LOCATION FED FROM NOTE CKT NO CIRCUIT NAME CBSIZE LOAD(KVA) PANEL DESCRIPTION 8 AM PI R H M L K 0 TOTAL 3 1 REC- EQUIPMENT STORAGE Al20 ! 1 0.5 10.5 PANEL AMPS : 225 FEEDERAMPS : 200 L - L VOLTS : 208 L - N V OLTS : 120 PHASE : 3 3 3 3 5 PRINTER- PRNTICXOPY 114 FURNITURE FEE) - OPEN OFFICE117 B C 20 1 1 20 11 1.5 1.5 1.2 1.2 3 7 FURNITURE FEED - OPEN OFFICE 117 A 20 1 1.2 1.2 3 9 SW. FURR FEED - OPEN OFFICE 117 B 20 11 0.7 `: I 0.7 -3 11 REG -PRIVATE OFFICE 116, 118, 120 C 20 :1 1.1 € 0.5 1.6 WIRE: 4 3 13 RECB PROJ. - MUATIPURFOSE ROOM 119 A 20 1 0.4 0.4 0-7 1:2 15 RED- CHILL ROOM B 20 1 0.5 `_. 0.5 3 17 MW- LUNCH ROOM 124 C 20 11 1.5 1.5 121 19 1 REC- BREAKROOM A 20 1 0.4 ; 0.4 M.L.O. 1:2 2 1 HINT B 20 j 1 1.8 1.8 MAIN CB X 200A 1,2 23 HINT C 20 j 1 1.8 1.8 FLUSH 1 25 _ FURNITURE FEED- WORKSTATION 111 A 20 11 i 0.9 0.9 - SURFACE X 1:2 1 27 29 RED- BATHROOM MAN- LUNCH ROOM 124 - B C 20 ' 1 20 11 0.4 -- 0.4 I 1 5 I 1.5 f ISO GND FEED THRU rl - -- _ i I LOADSUMMARY i i f I -O TAL,ALL BEC -TOES 1 f I RKY KVA : 9.0 3 2 FURNITURE FEED- OPEN OFFICE 117 A 20 11 1.2 1.2 3 4 FORNn-uRE F®- OPEN OFFICE 117 B 21) 11 1.2 1.2 FEAT I{VA : 3.6 3 6 SW FURN. FE@- OPEN OFFICE 117 C 20:1 0.7 ': - 0-7 MOTOR KVA : 0.7 3 3 8 10 RED- TOOL SHOP REC- TOOL SHOP -- A B 20 1 2D ; 1 0.4 0.4 0.4 0.4 LIGHTING KVA KITCHEN KVA : 4.6 1.2 12 iREC- TOOL SHOP C 20 20.2 -3- _ _ i 0.2 OTHER KVA : 8.1 1,2 14 - A - I - 0.2 0.2 2 16 REF B 20 1 1.6 PHASEA KVA : 6.2 2 98 REC- BREAKROOM C 20 1 1 0.2 I 0.2 AMPS : 51.5 2 20 RED- OFFICES NORTH A -.t-, 20 1 0.5 --i-_- 0.5 PHASE B KVA : 9.5 2 22 REC- OFFICES NORTH B 20 11 0.7 1 0.7 AMPS : 79.3 PHASECKVA : 10.3 2 24 RED- OFFICES NORTH C 20 1 1 0.7 0.7 1,2 1 26 28 RED- PANEL RED- LUNCH ROOM 124 A B 20 11 1 20 0.2D 0.7 0.2 .7 AMPS : 85.6 CONN TED LOAD KVA AMPS : 72.1 1,2 30 B(HIAU.UST FAN& RTU REC C ................... 20 1 ..... 0.2 0.7 ................ ................ ................ ................ ................ ................ ................ ................ ............... 0.9 ................ .............. ..... ............... ................ ................... ............................ € ........................ € € DEW D : 25.7 : 7VIE NOTESIREMARKS: DEMAND I CIV ERSITY FACTORS 1. REMOVE EXISTING CBANDPROVIDE (1)NEW 20A11P LOAD DESCRIPTION DpVIA(D CB. R RECEPTACLES - TO 10KVA 1000A = 9.0 Z EXISTING CIRCUIT, NO NEW LOAD. REMAINING OVER 10KVA 5(rX, - 3. NEW WORK LOAD CHANGED. H HEATING 1000/0 = 3.6 M MOTORS 100% = LM LARGEST MOTOR 125% = 0.8 L LIGHTING 125% _ K KITCHEN 909/0 = 4.1 0 OTHER 100% = 8.1 TITAN ELE CTRI C FULL SERVICE ELECTRICAL CONTACTOR 12828 NORTHUP WAY, SUITE 205 BELLEVUE, WA 98005 PH: 425-250-2581 FA: 206-374-2128 19515 North Creek Parkway, Suite 302 Bothell, Washington 98011 Phone: 425-402-9400 Fax: 425-402-9402 Project Title: Tenant Improvement for: NW Hydraulics QII Gj GENERAL NOTES 1. CIRCUIT NUMBERS SHOWN REFER TO PANEL P-1, P-2, OR P-3. SEE BREAKLINES, THIS SHEET. 2. CIRCUIT NUMBERS SHOWN INSIDE () ARE TO BE SWITCHED VIA CLOSEST RELATIVE OCCUPANCY SENSOR PER 2015 WSEC C405.10. — X—X—X—:'.— —X—X i s NORTH POWER & COMMUNICATIONIS FLOOR PLAN SCALE: 1/8" = 1'-0" - REVIEWED FOH COMPLIANCE "I' TH NPPA 70 - NEC SEP 13 2016 City ®f-TukWiaa BUILDING DIVISini,,,i RECEIVED CITY OF TUKWILA SEP 07 2016 TITAN ELECTRIC FULL SERVICE ELECTRICAL CONTACTOR 12828 NORTHUP WAY, SUITE 205 BELLEVUE, WA 98005 PH: 425-250-2581 FA: 206-374-2128 19515 North Creek Parkway, Suite 302 Bothell, Washington 98011 Phone: 425-402-9400 Fax: 425402-9402 Project Title: Tenant Improvement for: Nk'rw Hydraulics POWER & COMMUNICATIONS FLOOR PLAN Designed By: TN Drawn By: BY Project No: 16229 Date: 09/07/2016 Sheet Number. E1.1 GENERAL NOTES 1. CIRCUIT NUMBERS SHOWN REFER TO PANEL H2 UNLESS OTHERWISE NOTED. 2. REFER TO LIGHTING FIXTURE SCHEDULE, SHEET E0.1, FOR ADDITIONAL INFORMATION. FLAG NOTES 1� DAYLIGHT CONTROLLER SWITCHES TWO SETS OF FIXTURES. ZILV s% X 1 F7 17/ H3-113 1-7 17 M g,h.k, 17 TOOL SHOP Q EQUIPMENT F1 (E) I'll (E) Fl(E)i Fl(E) F1 (E) S10 OPEN 122 PI STORAGE 17h/S9 _17 S9 17h/ gL — -F' — ---- __�q — 17g/$9 15S9 ii it i i F1 (E) F1 (E) F1(E) !Fl(E) F1 (E) F7 F7 F7 17 1717 17 17 iii li 1 LV 71 1 B1 il lit it j 17k/S9 it 17m/S9 17k/S9 17m/S91, 17k/S9 it .1 171 1 1 F6 F6 S L 17/S9 17/S9 17/S9 17/S9 17/S9 j H3 -13/S10 H3 -13/S10 Fl-(E)-t3/S8 Fi( F1 (E) F1 (E) F1 (E) F1 (E) F1 (E) F7 S8 PRINT/17 17 17 tl COPY 17 ®X1(E) 13/S8 lit OR STORAGE 121 Ly V SHOWER F1 F1 F1 F1 li F1 (E) F1 (E) fi 1 F126 13 13 Ef3 13 F -3 M13 i 11 - --�= —JA—N. ij L�J`11 F7 OFFICE F1 (E) 113/S8..` 1 16 OFFICE OFFICE OFFICE .5 L H. 113 L 118 L120 J 15 FZ it 13 V SC====3 I F1 (E) 13 OFFICE F1 (E) 112 13 F1 (E) 13 ID OFFICE F1 (E) 13 I'll (E) 13 OFFICE F1 (E) 108 13 F! OFFICE 106 F1 (E) 13 13 F1 (E) i F1 (E), 13/Sb it S70 1; F1 (E) i',3/S8 liWORKSTATION I F1 (E) xip 15r 45 S. 4 F1 (E 15/S IMULTIPURPi I \ROOM! J F1 d 1 F1 -P 2 -F1 (E-)-21 -F4(E) -X -Y --X -X -X --X -x-X, t5/Sr @15 P" 1 FI(E)! F1 (E) MEN B1 LUNCH 125 1 15jS6 ROOM S6 F4(E) 1 !15 1, r FI(E) F1 (E) ZILV s% X 1 F7 17/ H3-113 1-7 17 M g,h.k, 17 TOOL SHOP Q EQUIPMENT F1 (E) I'll (E) Fl(E)i Fl(E) F1 (E) S10 OPEN 122 PI STORAGE 17h/S9 _17 S9 17h/ gL — -F' — ---- __�q — 17g/$9 15S9 ii it i i F1 (E) F1 (E) F1(E) !Fl(E) F1 (E) F7 F7 F7 17 1717 17 17 iii li 1 LV 71 1 B1 il lit it j 17k/S9 it 17m/S9 17k/S9 17m/S91, 17k/S9 it .1 171 1 1 F6 F6 S L 17/S9 17/S9 17/S9 17/S9 17/S9 j H3 -13/S10 H3 -13/S10 Fl-(E)-t3/S8 Fi( F1 (E) F1 (E) F1 (E) F1 (E) F1 (E) F7 S8 PRINT/17 17 17 tl COPY 17 ®X1(E) 13/S8 lit OR STORAGE 121 Ly V SHOWER F1 F1 F1 F1 li F1 (E) F1 (E) fi 1 F126 13 13 Ef3 13 F -3 M13 i 11 - --�= —JA—N. ij L�J`11 F7 OFFICE F1 (E) 113/S8..` 1 16 OFFICE OFFICE OFFICE .5 L H. 113 L 118 L120 J 15 FZ it 13 V SC====3 I F1 (E) 13 OFFICE F1 (E) 112 13 F1 (E) 13 ID OFFICE F1 (E) 13 I'll (E) 13 OFFICE F1 (E) 108 13 F! OFFICE 106 F1 (E) 13 13 F1 (E) i F1 (E), 13/Sb it S70 1; F1 (E) i',3/S8 liWORKSTATION I F1 (E) xip 15r 45 S. 4 F1 (E 15/S IMULTIPURPi I \ROOM! J F1 d 1 F1 -P 2 -F1 (E-)-21 -F4(E) Drawn By: @ 15 15/S6 15/S6 B1 1h FI(E) F1 (E) 15/'S6 1 1 S6 t5/Sr @15 F1 (E) F1 (E)i S5 L15/S5 15 614& 15/S5 F1 (E) am 5/ F1 (E) -S5 Xi 1—-5/-S5 15 F1 (E) F1 F1 4 LARGE 4 CONFERENCE El (E F1 F1 4 4 4 1 OFFICE OFFICE :L 1:17 HALL l.l 1117--V 104 1 F1 (E) 5/S3 4 S 113 OFFICE F1 (E) F1 15, 4 i OFFICE 13 Vs F1 (E) S3 1-3 B1 X1 (E) 4 15 \F1(E)15 RECEPTION F1 (E) 15f/S3 i 4 F51 i OFFICE '45' elf I/ - e ;155.3 15e/§: q F4 4/S2 F1 '111 5/S5 F1 4 4 F1 F1 4 OFfICEi OFFICE F-134 F4(E) 15@ F4(E) 15@ WOMEN 127 F4(E) 15@ F4 4/S2 B1 F1 4 4/S2 4/S2 sysl SERVER/E TOR 1IBRY S2 (E) 1 0 PLOTTER130 I El 4 0,4.4 X1 F1 (E) F1 (E) F1 (E) F1 (E) F1 (E) JF— SVS 4/S1.1 4/S7 4/S1 4/S1 4/S1 0131E 4 F1 (E) FI(E) F (E) 110 11 S F1 F1(E);, 4 , Fq 11 H 4/S1 4/Si qI it I 4/Sl 4/ VS it OPEN vp OFFICE 4 ii 4 OM it r 138 F1 (E) 14 n" I F,,* I (E) FI(E) 1 i OFFICE F1 B1 4%;S1(E) B 1 PH Si t 4 tzl 4d S1 4e,1/4f/S1F1 (E) 4f/Si 4 -A- -71 !SVS 4e/S1 F1 (E) 1'1(E) P1 (E) Ft (E) IG 14 Ad-- OFFIC F1 (E) F1 (E) F1 (E) 4a/S1 46/S1 46/S1 4a/S1 1334 ii a [>�5a.b,c, 4b/S1 4a 4b d,e,f II LIGHTING FLOOR PLAN SCALE: 1/8" = 1'-0" 10 F6 F6 H3-13/SlO H3 -13/S10 S10 ii' FISII F6 'S1O H3 -13/S10 F6 F6 H3 -13/S10 ii H3 -13(S10 F6 1 If F6 q,r q,r H3 -13/S10 H3-13/Sl 0 9 Sit F6 F6 --m ------- - --- n,p n,p H3 -13/S10 ji H3 -15/S10 '@n,p.q,r H3-13 Ill REVIEWED FOR COMPLIANCE tAv!T H NFPA 70 - NEC SEP 13 2016 City of-Tw(wile -- BUILDING DIVISICIN!, TITAN ELECTRIC FULL SERVICE ELECTRICAL CONTACTOR 12828 NORTHUP WAY, SUITE 205 BELLEVUE, WA 98005 PH: 425-250-2581 FA: 206-374-2128 19515 North Creek Parkway, Suite 302 Bothell, Washington 98011 Phone: 425-402-9400 Fax: 425-402-9402 Project Title: Tenant Improvement for: NW Hydraulics Designed By: TN Drawn By: BY Project No: F4(E) Date: ii 15/'S6 1 1 S6 t5/Sr @15 P" 1 FI(E)! F1 (E) MEN B1 LUNCH 125 1 15jS6 ROOM S6 F4(E) 1 !15 1, r FI(E) F1 (E) F1 (E) F1 (E)i S5 L15/S5 15 614& 15/S5 F1 (E) am 5/ F1 (E) -S5 Xi 1—-5/-S5 15 F1 (E) F1 F1 4 LARGE 4 CONFERENCE El (E F1 F1 4 4 4 1 OFFICE OFFICE :L 1:17 HALL l.l 1117--V 104 1 F1 (E) 5/S3 4 S 113 OFFICE F1 (E) F1 15, 4 i OFFICE 13 Vs F1 (E) S3 1-3 B1 X1 (E) 4 15 \F1(E)15 RECEPTION F1 (E) 15f/S3 i 4 F51 i OFFICE '45' elf I/ - e ;155.3 15e/§: q F4 4/S2 F1 '111 5/S5 F1 4 4 F1 F1 4 OFfICEi OFFICE F-134 F4(E) 15@ F4(E) 15@ WOMEN 127 F4(E) 15@ F4 4/S2 B1 F1 4 4/S2 4/S2 sysl SERVER/E TOR 1IBRY S2 (E) 1 0 PLOTTER130 I El 4 0,4.4 X1 F1 (E) F1 (E) F1 (E) F1 (E) F1 (E) JF— SVS 4/S1.1 4/S7 4/S1 4/S1 4/S1 0131E 4 F1 (E) FI(E) F (E) 110 11 S F1 F1(E);, 4 , Fq 11 H 4/S1 4/Si qI it I 4/Sl 4/ VS it OPEN vp OFFICE 4 ii 4 OM it r 138 F1 (E) 14 n" I F,,* I (E) FI(E) 1 i OFFICE F1 B1 4%;S1(E) B 1 PH Si t 4 tzl 4d S1 4e,1/4f/S1F1 (E) 4f/Si 4 -A- -71 !SVS 4e/S1 F1 (E) 1'1(E) P1 (E) Ft (E) IG 14 Ad-- OFFIC F1 (E) F1 (E) F1 (E) 4a/S1 46/S1 46/S1 4a/S1 1334 ii a [>�5a.b,c, 4b/S1 4a 4b d,e,f II LIGHTING FLOOR PLAN SCALE: 1/8" = 1'-0" 10 F6 F6 H3-13/SlO H3 -13/S10 S10 ii' FISII F6 'S1O H3 -13/S10 F6 F6 H3 -13/S10 ii H3 -13(S10 F6 1 If F6 q,r q,r H3 -13/S10 H3-13/Sl 0 9 Sit F6 F6 --m ------- - --- n,p n,p H3 -13/S10 ji H3 -15/S10 '@n,p.q,r H3-13 Ill REVIEWED FOR COMPLIANCE tAv!T H NFPA 70 - NEC SEP 13 2016 City of-Tw(wile -- BUILDING DIVISICIN!, TITAN ELECTRIC FULL SERVICE ELECTRICAL CONTACTOR 12828 NORTHUP WAY, SUITE 205 BELLEVUE, WA 98005 PH: 425-250-2581 FA: 206-374-2128 19515 North Creek Parkway, Suite 302 Bothell, Washington 98011 Phone: 425-402-9400 Fax: 425-402-9402 Project Title: Tenant Improvement for: NW Hydraulics Designed By: TN Drawn By: BY Project No: 16229 Date: 09/07/2016 �- 15e/S: Calculation Summary Label CalcType Units Avg Max Min Avg/Min Max/Min EMERGENCY EGRESS PATHWAY OFFICE Illuminance Fc 1.18 5.2 0.2 5.90 26.00 LAB EGRESS PATHWAY Illuminance Fc 1.01 5.4 0.2 5.05 27.00 STORAGE EGRESS PATHWAY Illuminance Fc 1.44 4.7 0.2 7.20 23.50 LIGHTING EGRESS CALCULATIONS SCALE: 1/8" = 1'-0" Im -X- X -X -X -X -X -X l v ,x TITAN ELECTRIC FULL SERVICE ELECTRICAL CONTACTOR 12828 NORTHUP WAY, SUITE 205 BELLEVUE, WA 98005 PH: 425-250-2581 FA: 206-374-2128 11h, CASE N ENGINEERING Consulting Electrical Engineers 19515 North Creek Parkway, Suite 302 Bothell, Washington 98011 Phone: 425-402-9400 Fax: 425-402-9402 Project Title: Tenant Improvement for: N W Hydraulics - REVIEWED FOR Gateway Corp. Ctr. Bldg 6 COMPLIANCE WIT H 12787 Gateway Dr. NPPA 70 - N117-0 Tukwila WA 98168 SEP 13 2016 Sheet Title: City Of TUkWW1lP, RECEIVED CITY OF TUKWILA SEP 07 2016 PERMIT CENTER LIGHTING EGRESS CALCULATIONS Designed By: TN Drawn By: BY Project No: 16229 Date: 09/07/2016 Sheet Number: L2 0A