Loading...
HomeMy WebLinkAboutPermit EL16-0823 - AT&T - FLOOR BOXESAT&T 1010 SOUTHCENTER MALL EL16-0823 City of Tukwila • Department of Community Development + 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Inspection Request Line: 206-438-9350 Web site: http://www.TukwilaWA.Rov ELECTRICAL PERMIT Parcel No: 9202470010 Permit Number: EL16-0823 Address: 1010 SOUTHCENTER MALL Issue Date: 10/19/2016 International Residential Code Edition: Permit Expires On: 4/17/2017 Project Name: AT & T 2014 Owner: 2015 Name: WESTFIELD PROPERTY TAX DEPT 2014 Address: PO BOX i30940, CARLSBAD, CA, 2015 92013 2015 Contact Person: 2015 Name: MARSIAL SEDA Phone: (562) 216-5244 Address: 111 W OCEAN BLVD, #1750, LONG BEACH, CA, 90802 Contractor: Name: OLSEN ELECTRIC INC Phone: (253) 872-1905 Address: 325 WASHINGTON AVE S #91, KENT, WA, 98032 License No: OLSENE1931PE Expiration Date: 10/5/2017 Lender: Name: Address: DESCRIPTION OF WORK: CORE -DRILL CONCRETE FOR NEW FLOOR BOXES. DEMOLISH ONE EXISTING ELECTRICAL PANEL, AND EXISTING LIGHTING, POWER/DATA AND SALES FLOOR. INSTSALL NEW POWER/DATA ANDLIGHTING AT SALES FLOOR. Valuation of single family: $0.00 Fees Collected: $353.34 Valuation of mf/comm: $10,000.00 Type of Work: TENANT IMP Electrical Service Provided by: PUGEST SOUND ENERGY Water District: TUKWILA Sewer District: TUKWILA Current Codes adopted by the City of Tukwila: International Building Code Edition: 2015 National Electrical Code: 2014 International Residential Code Edition: 2015 WA Cities Electrical Code: 2014 International Mechanical Code Edition: 2015 WAC 296-46B: 2014 Uniform Plumbing Code Edition: 2015 WA State Energy Code: 2015 International Fuel Gas Code: 2015 Permit Center Authorized Signature:wV MW)c Date: I hearby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this development permi;-rand agree to the conditions attached to this permit. Signature Print Nam Date: to - /q— I4 This permit shall become null and void if the work is not commenced within 180 days for the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. PERMIT CONDITIONS: <NONE> PERMIT INSPECTIONS REQUIRED Permit Inspection Line: (206) 438-9350 2100 ELECTRICAL FINAL 7003 ROUGH -IN ELECTRICAL 7002 SERVICE 7001 UNDERGROUND/SLAB CITY OF TUKWILA Community Development Department • Permit Center • 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 " http://www.TukwilaWA.gov Electrical Permit No.. Project No. Date Application Accepted: Date Application Expires: 22 -% f �� T use ELECTRICAL PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. "Please Print" SITE LOCATION I n King Co Assessor's Tax No.: R2 O2 Ll -7 - 001 O Site Address: - 1 V 10 • 1.u -K c E nie, Nva l l Suite Number: 316 Floor: � Tenant Name: tl'rx-T New Tenant: .Yes ❑..No PROPERTY OWNER Name: r Address: C409 S• 24e 20 City: State: -r b Zip:8 3616 V CONTACT PERSON - person receiving all project communication Name: SG Address: t1 VJOce„ 81vd 417S0 City: State: GA Zip: 908 Phone: S62 S Fax: Qu Email: W1.SQ t M ELECTRICAL CONTRACTOR INFORMATION Company Name: --Ub Address: City: State: Zip: Phone: Fax: Contr Reg No.: Exp Date: Tukwila Business License No.; Valuation of Project (contractor's bid price): $ 10.� 000 Scope of Work (please provide detailed information): inA -c r-a^r-1ti4Q -Q r- w 66) 2000r U4, Qr e K. 0 Will service be altered? ❑ Yes m No Adding more than 50 amps? ❑ Yes m No Type of Use: Mercantile- cell phone store Type of work: ❑ New ❑ Addition ❑ Service Change ❑ Remodel m Tenant Improvement ❑ Low Voltage ❑ Generator ❑ Fire Alarm ❑ Telecommunication ❑ Temporary Service Property Served by: ❑ Puget Sound Energy ❑ Seattle City Light H:\Applications\Formt-Applications On Line\2014 ApplicationsTlectrical Permit Application Revised 1-1-14.docx Revised: January 2014 bh Page I of 2 RESIDENTIAL NEW RESIDENTIAL SERVICE ❑ New single family dwellings ................................... $152.85 (including an attached garage) ❑ Garages, pools, spas and outbuildings ........................ $81.90 ea ❑ Low voltage systems (alarm, furnace thermostat) ................................ $59.85 ea RESIDENTIAL REMODEL AND SERVICE CHANGES ❑ Service change or alteration ...................................... $81.90 (no added/altered circuits) $80.90 ❑ Service change with added/altered circuits ................. $81.90 number of added circuits .......................$11.55 ea ❑ Circuits added/altered without service change ........... $54.60 (up to 5 circuits) $10.80 ea ❑ Circuits added/altered without service change ........... $54.60 (6 or more circuits) ............................................... $7.65 ea ❑ Meter/mast repair ....................................................... $68.25 ❑ Low voltage systems ................................................. $59.85 (alarm, furnace thermostat) PERMIT APPLICATION NOTES - MULTI -FAMILY AND COMMERCIAL Fees are based on the valuation of the electrical contract. MISCELLANEOUS FEES ❑ Temporary service (residential) ................................. $65.00 ❑ Temporary service (generator) ................................... $80.90 ❑ Manufactured/mobile home service ........................... $86.25 (excluding garage or outbuilding) ❑ Carnivals.................................................................... $80.60 Number of concessions ......................... $10.80 ea Each ride and generator truck ............... $10.80 ea ***EFFECTIVE JANUARY 1, 2014 EACH PERMIT WILL BE ASSESSED A 5% TECHNOLOGY FEE*** Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation The Building Official may grant one extension of time for an additional period not to exceed 90 days. The extension shall be requested in writing and justifiable cause demonstrated. I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. OR El61;G9PR4GAl6 GONTRA Q Print Mailing Date: O 1 - D'• Za 16 Day Telephone: ZZ 2 • 2-16. S'-'2 Ll 4 ) 1*17SD 1--o, H:Wpplications\Forrns-Applications On Line12014 ApplicationsTlectrical Permit Application Revised 1-1-14.do" Revised: January 2014 bh G4 `I c'184 Z State Zip Page 2 of 2 DESCRIPTIONS ACCOUNT QUANTITY PAID PermitTRAK $285.39 EL16-0823 Address: 1010 SOUTHCENTER MALL Apn: 9202470010 $285.39 ELECTRICAL $271.80 PERMIT FEE MULTI-FAM/COMM R000.322.101.00.00 0.00 $271.80 TECHNOLOGY FEE $13.59 TECHNOLOGY FEE TOTAL FEES PAID.. . 1 R000.322.900.04.00 0.00 $13.59 Date Paid: Wednesday, September 21, 2016 Paid By: CORNELIA DOREKAMP Pay Method: CREDIT CARD 01000D Printed: Wednesday, September 21, 2016 9:10 1 of 1 (r/7"IfV SYSTElv15 AM DESCRIPTIONS PAID PermitTRAK - $929.11 D16-0249 Address: 344 SOUTHCENTER MALL Apn: 9202470010 $811.36 DEVELOPMENT $811.36 PLAN CHECK FEE R000.345.830.00.00 0.00 $811.36 EL16-0823 Address: Apn: $67.95 ELECTRICAL $67.95 PLAN CHECK FEE R000.345.832.00.00 0.00 $67.95 M16-0139 Address: 344 SOUTHCENTER MALL Apn: 9202470010 $49.80 MECHANICAL $49.80 PLAN CHECK FEE TOTAL FEES PAID BY RECEIPT: .. 363 R000.322.102.00.00 0.00 $49.80 $929.11 Date Paid: Thursday, September 08, 2016 Paid By: DP INC GENERAL CONTRACTORS Pay Method: CHECK 4053 Printed: Thursday, September 08, 2016 1:25 PM 1 of 1 p"fSYS7EM5 INSPECTION RECORD Retain a copy with permit ✓�� INSPECTION NO. PERMIT N0. 4 CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd- #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Project: -A�d— 7— Type of Inspection: eJ' Address: (t) Date Called: Special Instructions: I a. Date Wanted: tC J30.m. Requester: Phone No: C9Approved per applicable codes. 1-1 Corrections required prior to approval. Inspector: Date. I 11 {��/ Iit ho h, El REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. INSPECTION RECORD y�j Retain a copy with permit 0 INSPEC ION N0. ERMIT N0. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd.., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Project: -Ae�qType of Inspection: Al/ Address: Olt� IQ/Special Date Called: Instructions: t Date Wanted: a.m. I Z, p.m. Requester: hh&� Phone No: MApproved per applicable codes. Corrections required prior to approval. COMMENTS: Inspector: Date: lI 't �� b El REINSPECTIOIN FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Calt to schedule reinspection. INSPECTION RECORD Retain a copy with permit INSPECTION N0. IIERMIT N0. CITY OF TUKWILA BUILDING DIVISION Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-367f- 6300 Permit Inspection Request Line (206) 438-9350 L� Corrections required prior to approval. REINSPECTIO14 FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. INSPECTION RECORD �j Retain a copy with permit -OM INSPECTION NO. PERMIT N0. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Project: Type of Inspe Iroal-I j Address: /0(0 Date Called: Special Instructions: Date Wanted: ` a.m. m. Requester: Phone No: FlApproved per applicable codes. t__..J Corrections required prior to approval. `J paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. INSPECTION RECORD EL'&08�.3 Retain a copy with permit INSPECTION NO. PERMIT NO. i CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Project:I d T Type of Inspection'_S Address`: U10 �04k Date Called: Special Instruction�s:�, b'�yt�J Date Wanted: a.m. Requester: Phone No: 11 Approved per applicable codes. 11 Corrections required prior to approval. 4 REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. PLAN REVIEW/ROUTING SLIP PERMIT NUMBER: EL16-0823 DATE: 09/08/16 PROJECT NAME: AT & T SITE ADDRESS: 1010 SOUTHCENTER MALL X Original Plan Submittal Revision # before Pbrmit Issued Response to Correction Letter # Revision # after Permit Issued DEPARTMENTS: oi�, Aw �- q,G- t P Building Division & Fire Prevention ❑ Planning Division ❑ Public Works ❑ Structural ❑ Permit Coordinator ❑ PRELEME NARY REVIEW: DATE: 09/13/16 Not Applicable ❑ Structural Review Required ❑ (no approval/review required) REVIEWER'S INITIALS: APPROVALS OR CORRECTIONS: Approved C Corrections Required ❑ (corrections entered in Reviews) N REVIEWER'S INITIALS: DATE: DUE DATE: Approved with Conditions X Denied ❑ (ie: Zoning Issues) DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: 12/18/2013 10/11/16 OLSEN ELECTRIC INC Washington State Deparhnent of Labor & Industries OLSEN ELECTRIC INC Owner or tradesperson Principals OLSEN, ERIC S, PRESIDENT OLSEN, ERIC S, AGENT Doing business as OLSEN ELECTRIC INC I -Ionic. Espanol Contact Safety & Health Page 1 of 5 A -Z Index Ifelp MyL&I Claims & Insurance Workplace Rights Trades & Licensing 325 WASHINGTON AVE S #91 KENT, WA 98032 253-872-1905 KING County WA UBI No. Business type 602 696 333 Corporation License Verify the contractor's active registration / license / certification (depending on trade) and any past violations. Electrical Contractor Active. Meets current requirements. License specialties GENERAL License no. OLSENEI931 PE Effective — expiration 10/05/2007-10/05/2017 Designated administrator Active. OL$EN, ERIC S Meets current requirements. License type License no. Electrical Administrator OLSENES9610H Bond .._........... Violation amount CBIC $4,000.00 Bond account no. SI4815 Received by L&I Effective date 12/28/2009 01/24/2010 Expiration date Until Canceled Savings No savings accounts during the previous 6 year period. License Violations Infraction no. EJACH00948 Satisfied .................._... Issue date RCW/WAC 08/02/2016 19.28.161 RCW Violation city Violation amount KENT $500.00 Type of violation https://secure.Ini.wa. gov/verify/Detail.aspx?UBI=602696333 &LIC=OLSENEI931 PE&SAW= Help us improve 10/19/2016 J T N O O 1.0 NAMEPLATES 1.0 GROUNDING AND BONDING BLACK BROWN 1.1GENERAL: FURNISH AND MOUNT ON EACH PANEL BOARD/SWITCHBOARD (INCLUDING BRANCH 1_1 GROUND ALL EQUIPMENT PER N.E.C. BLUE SWITCHES), LARGE JUNCTION BOX, SAFETY SWITCH, STARTER, REMOTE CONTROL, PUSHBUTTON NEUTRAL WHITE GREY STATION, AND ALL SIMILAR CONTROLS A NAMEPLATE DESCRIPTIVE OF THE EQUIPMENT OR 1_2 GROUND ALL DRY TYPE TRANSFORMERS AS PER DRAWINGS AND N.E.C. EQUIPMENT CONTROLLED. STOP IN ALL OPENINGS CREATED THROUGH FIRE -RATED WALLS, FLOORS, OR CEILINGS. J SHALL BE THE EQUAL OF 3M PRODUCTS SCOTCH #35. 1_3 ALL CONDUITS SHALL CONTAIN A CODE -SIZED GROUND WIRE SIZE PER N.E.C. IN ADDITION TO 1.2 PROVIDE BLACK AND WHITE NAMEPLATES CONSTRUCTED FROM LAMINATED PHENOLIC WITH A THE CONDUCTORS SHOWN ON THE PLANS. WHERE CIRCUIT CONDUCTORS ARE INCREASED IN SIZE WHITE CENTER CORE. LETTERS SHALL BE ENGRAVED IN THE PHENOLIC TO FORM WHITE rC FOR VOLTAGE DROP, THE GROUND WIRE SIZE SHALL BE INCREASE PROPORTIONATELY. co LETTERS 3/8" HIGH. FASTEN THE NAMEPLATES WITH SCREWS AND ADHESIVE FASTENER. 4.0 MATERIALS AND WORKMANSHIP C 1.4 WHERE AN ISOLATED, INSULATED GROUND IS REQUIRED A SEPARATE GREEN GROUND SHALL BE 2.0 MOUNTING ACCESSORIES 4.1ALL RUN FROM THE PANEL GROUND BUS TO THE ISOLATED GROUND CONNECTION OF THE DEVICE W FOR #10AWG AND SMALLER. THHN SHALL NOT BE USED IN WET OR DAMP LOCATIONS. W SERVED. IN NO CASE SHALL THE SYSTEM GROUND (WIRE AND ASSOCIATED OUTLET BOXES, 2.1 THIS CONTRACTOR SHALL FURNISH AND INSTALL ALL ANGLE IRON, CHANNEL IRON, RODS, CONDUIT AND BUILDING STEEL) BE ALLOWED TO CONTACT THE ISOLATED GROUND (GREEN WIRE 1_3 SUPPORTS, HANGERS, CONCRETE OR PLYWOOD REQUIRED TO INSTALL, MOUNT AND SUPPORT 4.2 AND DEVICE GROUND). 7w ANY ELECTRICAL EQUIPMENT OR DEVICE CALLED FOR ON THE PLANS. SEVERAL KINDS UNLESS SPECIFIED OR INDICATED ON THE DRAWINGS TO THE CONTRARY. 2 2SUPPORTING TERIAL SHALL BE COMPLETE WITH HANGERS, CONNECTORS, BOLTS, CLAMPS, PHALLND DIVISION 16120 WIRE AND CABLE DURING EACH PHASE AND AT THE COMPLETION OF THE CONSTRUCTION, THIS CONTRACTOR SHALL NECESSARY ACCESSOR ES TO MAKE A COMPLETE INSTALLATION. SUPPORTING MATERIA BIDDING. REMOVE ALL DEBRIS AND EXCESS MATERIALS CAUSED BY HIS WORK. HE SHALL LEAVE THE AREA BE GALVANIZED, PAINTED OR OTHERWISE SUITABLY FINISHED. PRODUCTS BY BINKLEY, STEEL CITY PROVIDE MINIMUM #12 CONDUCTORS, UNLESS OTHERWISE INDICATED. OF OPERATION BROOM CLEAN. OR RACO WILL BE ACCEPTABLE. 1.0 WIRE AND CABLE 2_3 ALL SURFACE -MOUNTED EQUIPMENT ON BLOCK WALLS SHALL BE MOUNTED ON 3/4" PLYWOOD 1-1 COLOR CODE CONDUCTORS (EXCEPT CONTROL AND INSTRUMENTATION CONDUCTORS) AS BACKBOARD. ALL FLOOR -MOUNTED EQUIPMENT SHALL BE INSTALLED ON A 4" HIGH CONCRETE PAD. CLASS 2. FOLLOWS. 3.0 EXECUTION 3_1 THE ELECTRICAL WORK FOR CONSTRUCTION PURPOSES SHALL CONFORM TO ALL FEDERAL (OSHA), STATE, ALL SPECIFIC SAFETY REQUIREMENTS AND THE CURRENT EDITION OF THE NEC. 3_2 CHECK THE HVAC AND PLUMBING SPECIFICATIONS FOR ELECTRICAL REQUIREMENTS AND INCLUDE THE SAME IN THE CONTRACT COST. 3.3 EQUIPMENT CONNECTIONS, STARTERS, DISCONNECT SWITCHES, CONTROL TRANSFORMERS AND PUSH-BUTTON STATIONS FOR THE EQUIPMENT FURNISHED BY THE OWNER OR UNDER A SEPARATE CONTRACT SHALL BE INSTALLED AND CONNECTED UNDER THIS DIVISION, AS INDICATED ON THE CONTRACT DRAWINGS. 3_4 120/208 277/480 PHASE A BLACK BROWN PHASE B RED ORANGE PHASE C BLUE YELLOW NEUTRAL WHITE GREY GROUND GREEN GREEN 3_4 ALL CUTTING, PATCHING, EXCAVATING, BACK FILLING AND CONCRETE WORK RELATED TO THIS 1.1a #12 AND #10 CONDUCTORS SHALL HAVE CONTINUOUS INSULATION COLOR, AS LISTED ABOVE. CONTRACT WILL BE THE RESPONSIBILITY OF THE ELECTRICAL CONTRACTOR. THIS CONTRACTOR r M SHALL ASSUME THE RESPONSIBILITY OF PROVIDING THE SLEEVES, CHASES AND OPENINGS 1,1b CONDUCTORS LARGER THAN ABOVE, WHICH DO NOT HAVE CONTINUOUS INSULATION COLOR NECESSARY FOR THE ELECTRICAL INSTALLATION AND FOR THEIR REPAIR IN AN ACCEPTABLE SHALL BE COLOR CODED BY APPLICATION OF AT LEAST TWO LAPS OF COLORED TAPE ON MANNER, AS DETERMINED BY THE ARCHITECT. ALL HOLES SHALL BE CORE -DRILLED. PROVIDE FIRE EACH CONDUCTOR AT ALL POINTS OF ACCESS INCLUDING JUNCTION BOXES. COLOR TAPE STOP IN ALL OPENINGS CREATED THROUGH FIRE -RATED WALLS, FLOORS, OR CEILINGS. J SHALL BE THE EQUAL OF 3M PRODUCTS SCOTCH #35. 3_5 THIS CONTRACTOR SHALL BE RESPONSIBLE FOR PROVIDING ALL REQUIRED ACCESS PANELS 0<c�T- 1.1c CONDUCTORS SHALL BE SOFT ANNEALED COPPER INSULATED FOR 600 VOLTS UNLESS NECESSARY FOR HIS WORK, COORDINATE WITH ARCHITECT PRIOR TO INSTALLATION. SPECIFICALLY INDICATED OTHERWISE. ALUMINUM CONDUCTORS ARE NOT ALLOWED ON THIS rC < co PROJECT. 4.0 MATERIALS AND WORKMANSHIP C ry 1_2 INSULATION TYPE SHALL BE TYPE THW FOR WIRE SIZES #8 AWG AND LARGER AND THHN OR THWN 4.1ALL WORK SHALL BE INSTALLED IN A PRACTICAL WORKMANLIKE MANNER BY MECHANICS SKILLED IN W FOR #10AWG AND SMALLER. THHN SHALL NOT BE USED IN WET OR DAMP LOCATIONS. W THE SEVERAL TRADES NECESSARY <UJ 1_3 PROVIDE WIRE AND RACEWAY SYSTEM AS DESCRIBED HEREIN AND AS INDICATED ON THE 4.2 ALL MATERIALS SHALL BE NEW AND FREE FROM DEFECTS AND SHALL BE THE BEST OF THEIR 7w DRAWINGS. METAL -CLAD (MC.) ARMORED CABLE (AC) AND NON-METALLIC SHEATHED CABLE (NMC) SEVERAL KINDS UNLESS SPECIFIED OR INDICATED ON THE DRAWINGS TO THE CONTRARY. =U~ SHALL NOT BE PERMITTED UNLESS NOTED SPECIFICALLY OTHERWISE AND APPROVED PRIOR TO 4.3 DURING EACH PHASE AND AT THE COMPLETION OF THE CONSTRUCTION, THIS CONTRACTOR SHALL 06W BIDDING. REMOVE ALL DEBRIS AND EXCESS MATERIALS CAUSED BY HIS WORK. HE SHALL LEAVE THE AREA 1_4 PROVIDE MINIMUM #12 CONDUCTORS, UNLESS OTHERWISE INDICATED. OF OPERATION BROOM CLEAN. 4.4 ALL ELECTRICAL EQUIPMENT SHALL BEAR THE UNDERWRITERS LABORATORIES LABEL OR ETL 1.4a CONTROL CONDUCTORS SHALL BE #14 MINIMUM FOR N.E.C. CLASS 1 AND #16 FOR N.E.C. CLASS 2. LABEL. 4_5 THIS CONTRACTOR SHALL GUARANTEE HIS WORKMANSHIP AND MATERIAL (LAMPS EXCEPTED) FOR 1_5 CONDUCTORS #8 AWG AND LARGER SHALL BE STRANDED. A PERIOD OF ONE YEAR FROM THE DATE OF BUILDING OPENING AND LEAVE HIS WORK IN PERFECT 1.6 CONDUCTORS #10 AWG AND SMALLER SHALL BE SOLD ORDER AT THE COMPLETION. SHOULD DEFECTS DEVELOP WITHIN THE GUARANTEE PERIOD, THE - CONTRACTOR SHALL, UPON NOTICE OF THE SAME, REMEDY THE DEFECTS AND HAVE ALL 1_7 INSTALL ALL WIRING IN CONDUIT. DAMAGES TO OTHER WORK OR FURNISHINGS CAUSED BY THE REPAIRS CORRECTED AT HIS EXPENSE TO THE CONDITION BEFORE SUCH DAMAGE. 1.8 CONNECT #10 AND SMALLER WIRES WITH CONSTANT PRESSURE EXPANDABLE SPRING TYPE CONNECTORS, "SCOTCHLOK" BY 3M OR B -CAP BY BUCHANAN. 5.0 SCOPE OF WORK 1_9 CONNECT #8 AND LARGER WIRES WITH COMPRESSION CONNECTORS OR SPLICES AS 5.1 THE ELECTRICAL CONTRACTOR SHALL PROVIDE ALL LABOR, MATERIAL, STORAGE, UNPACKING AND MANUFACTURED BY BURNDY OR T&B. PLACEMENT; TO INCLUDE BUT NOT BE LIMITED TO, THE FOLLOWING ITEM: 1.10 INSULATE SPLICING CONNECTORS TO AT LEAST 200% OF THE WIRE INSULATION. USE 5.1a EMERGENCY LIGHTING AND POWER - PRE -STRETCHED TUBING CONNECTOR INSULATORS. 3M PST FOR #2 AND LARGER CONDUCTORS. 5.1b COMPLETE POWER AND LIGHTING DISTRIBUTION SYSTEM INCLUDING ALL TRANSFORMERS 1.11 PULL CONDUCTORS USING RECOGNIZED METHODS AND EQUIPMENT LEAVING AS LEAST 6" WIRE AT AND FEEDERS ALL JUNCTION BOXES FOR CONNECTIONS. 5.1c COMPLETE BRANCH CIRCUIT WIRING SYSTEM. 1.1 la CLEAN OUT EACH CONDUIT SYSTEM BEFORE PULLING WIRE. 5.1d COMPLETE POWER WIRING FOR ALL AIR CONDITIONING EQUIPMENT, PLUMBING 1,12 FORM AND TIE ALL WIRING IN PANEL BOARDS. SYSTEM, HEATING EQUIPMENT, VENTILATING AND EXHAUST EQUIPMENT. 1.13 THERE SHALL BE NO WIRE NUT JOINTS OR SPLICES MADE INSIDE SWITCHBOARDS/ PANEL BOARDS. 5.1e COMPLETE LIGHTING FIXTURE INSTALLATION, INCLUDING ALL INCANDESCENT, FLUORESCENT AND HID LAMPS. 1.14 BRANCH CIRCUIT WIRE SIZES (AND CONDUITS) SHALL BE INCREASED FROM THOSE INDICATED ON THE PLANS TO PREVENT EXCESSIVE VOLTAGE DROP. BRANCH CIRCUITS SHALL BE INSTALLED WITH 5.1f COMPLETE COMMUNICATIONS CONDUIT AND WIRING SYSTEM INCLUDING BOXES, PLATES, WIRES OF SUFFICIENT SIZE SO THAT VOLTAGE DROP BETWEEN THE PANEL AND THE LOADS DOES JACKS, ETC., AS SPECIFIED, SHOWN ON THE DRAWINGS AND REQUIRED BY THE TENANT. NOT EXCEED LIMIT OF 35. 5_1g TEMPORARY ELECTRICAL POWER AND LIGHTING AS REQUIRED FOR CONSTRUCTION. 1.15 WIRE SIZES SHALL BE BASED ON THE 60°C. AMPACITIES FOR WIRE SIZES NO. 14-1 A.W.G., AND 75°C. AMPACITIES FOR WIRE SIZES #1/0 A.W.G. AND LARGER. 5.1 h TESTING OF ALL CABLES AND CIRCUIT WIRING AFTER INSTALLATION. 1.16 CIRCUITS MAY BE MULTI-PLEXED IN CONDUIT PROVIDED WIRE IS PROPERLY DERATED AND 5_1 ii EXIT LIGHT SYSTEM. CONDUIT SIZED PER CODE. UNDER NO CIRCUMSTANCES SHALL MORE THAN (9) CURRENT CARRYING CONDUCTORS BE RUN 1N A SINGLE CONDUIT. 5.11 WIRING DEVICES AND FLOOR BOXES. 1.17 PROVIDE WIRE AND RACEWAY SYSTEMS AS DESCRIBED HEREIN AND INDICATED ON DRAWINGS. 5.1k LIGHTING CONTROLS. METAL -CLAD (MC), ARMORED CABLE (AC), AND NON-METALLIC SHEATED CABLE (NMC) SHALL NOT BE PERMITTED, UNLESS NOTED SPECIFICALLY OTHERWISE AND APPROVED PRIOR TO 5.11GROUNDING OF THE ELECTRICAL SYSTEM. - BIDDING. 5.1m FIRE SUPERVISORY ALARM SYSTEM. 5.1 n TELEPHONE AND ELECTRIC SERVICES 5.10 SOUND SYSTEM COMPONENTS, CONDUIT SYSTEM & WIRING DIVISION 16130 - RACEWAYS AND BOXES 1.0 RACEWAYS 1.1 ALL WIRE SHALL BE RUN IN ACCORDANCE WITH CODE IN CORROSION RESISTANT, RIGID, THREADED, METAL CONDUIT OR ELECTRICAL METALLIC TUBING (E.M.T.) UNLESS OTHERWISE SPECIFICALLY STATED HEREIN. 1.2 CONDUIT SIZE SHALL BE 3/4" MINIMUM. 1.3 CONDUIT SHALL BE SECURELY FASTENED IN PLACE. 1.4 ALL CONDUIT SHALL BE CONCEALED IN WALLS, FLOOR AND CEILINGS WHEREVER POSSIBLE. EXPOSED CONDUIT IN FINISHED AREAS WILL NOT BE PERMITTED. EXPOSED CONDUIT WILL BE PERMITTED IN UNFINISHED AREAS WITH THE SPECIFIC APPROVAL OF THE ARCHITECT. 1.5USE FLEXIBLE CONDUIT FOR THE CONNECTION TO RECESSED OR SEMI -RECESSED LIGHTING FIXTURES (6' LENGTH MAXIMUM). USE LIQUID TIGHT METAL CONDUIT FOR ALL CONNECTIONS TO MOTORS AND OTHER EQUIPMENT SUBJECT TO VIBRATION AND IN AREAS SUBJECT TO MOISTURE. 1_6 USE WATERTIGHT JOINTS WITH BURIED AND CONCRETE ENCASED CONDUIT. ALL BURIED CONDUIT OUTSIDE OF BUILDINGS SHALL HAVE A MINIMUM OF 24" OF COVER. METAL CONDUITS BURIED IN EARTH SHALL BE PAINTED (TWO COATS) WITH HEAVY ASPHALTUM PAINT. 1.7 SUPPORT RUNS OF CONDUIT AS DETAILED IN THE APPROPRIATE TABLE OF THE NATIONAL ELECTRICAL CODE (NEC). 1_8 INSTALL EXPOSED RUNS OF CONDUIT AND CONDUIT ABOVE LAY -IN CEILING PARALLEL OR PERPENDICULAR TO THE WALLS, STRUCTURAL MEMBERS OF INTERSECTIONS OF VERTICAL PLANES AND CEILINGS. PROVIDE RIGHT ANGLE TURNS USING FITnINGS OR SYMMETRICAL BENDS. SUPPORT CONDUITS WITHIN 1" OF ALL CHANGES IN DIRECTION. 1_9 IF A CONDUIT IS SUSPENDED, IT SHALL BE SUPPORTED ON TRAPEZE HANGERS WHICH USE "ALL -THREAD" RODS FROM THE STRUCTURAL STEEL. THE USE OF CEILING SUPPORT WIRE OR SIMILAR MATERIAL WILL NOT BE ACCEPTED. 1.10 INSTALL EMPTY CONDUIT FOR FUTURE USE AS INDICATED ON THE DRAWINGS. CONDUIT SHALL BE COMPLETE WITH JETLINE OR PULL ROPE, JUNCTION/OUTLET BOXES, TILE RINGS AND APPROPRIATE COVER PLATES. 1.11 PROVIDE PITCH POCKETS WHERE CONDUITS PENETRATE THE ROOF. 1.12 THREAD LUBRICATION/SEALANT IS REQUIRED ON OUTDOOR AND UNDERGROUND THREADED METAL JOINTS. 1.13 INSTALL FIRE SEAL FITTINGS WHERE CONDUITS PENETRATE CONCRETE FLOOR SLABS OR MASONRY WALLS REQUIRED TO BE FIRE RATED. 1.14 HORIZONTAL PORTION OF CONDUIT EXPOSED ON THE ROOF AND FEEDING EQUIPMENT SHALL NOT BE MORE THAN 5'-0" UNLESS THE WRITTEN APPROVAL FROM ARCHITECT OR ENGINEER IS OBTAINED. 2.0 PULL AND JUNCTION BOXES 2_1 INSTALL PULL AND JUNCTION BOXES WHERE SHOWN ON THE DRAWINGS, AND WHERE REQUIRED FOR CHANGES IN DIRECTION, AT JUNCTION POINTS, AND TO FACILITATE WIRE PULLING. FURNISH BOX SIZES IN ACCORDANCE WITH NEC UNLESS LARGERBOXES ARE INDICATED. 2_2 PROVIDE STEEL BOXES AND REMOVABLE COVERS OF CODE GAGE, HOT ROLLED SHEET STEEL, HOT DIPPED GALVANIZED INSIDE AND OUTSIDE, FOR ABOVE GROUND WORK. FURNISH WEATHERPROOF BOXES WHEN INSTALLED ABOVE GROUND OUTSIDE. 2_3 PROVIDE CAST IRON BOXES, HOT DIPPED GALVANIZED NSIDE AND OUTSIDE WHERE SHOWN ON THE DRAWINGS. FURNISH REMOVABLE COVERS WITH GASKETS AND STAINLESS STEEL, BRASS OR BRONZE SCREWS. 2.4 PROVIDE CONCRETE BOXES FOR UNDERGROUND WORK UNLESS OTHERWISE INDICATED ON THE DRAWINGS. FURNISH STEEL FRAMES AND COVERS WITH THE COVER ATTACHED TO THE FRAME WITH HEXAGON HEAD, BRASS OR BRONZE CAP SCREWS, 3/8" IN DIAMETER. PROVIDE A RUBBER GASKET FOR SEALING BETWEEN THE COVER AND THE FRAME. PAINT THE COVER WITH TWO COATS OF HEAVY ASPHALTUM. 3.0 OUTLET BOXES 3_1 USE SHEET STEEL BOXES, ZINC COATED OR CADMIUM PLATED, FOR CONCEALED INTERIOR WORK. 3_2 USE CAST BOXES, ZINC -CADMIUM FINISH MALLEABLE IRON, FOR EXPOSED INTERIOR WORK, AND FOR EXPOSED OR CONCEALED WORK IN WET, DAMP OR EXTERIOR LOCATIONS. CAST BOXES SHALL BE SERIES FD BY CROUSE HINDS OR APPLETON. 3_3 WALL BOX SIZES (MINIMUM) SHALL BE 4" SQUARE X 2-1/2"DEEP WHERE WALL CONSTRUCTION PERMITS. WHERE WALL CONSTRUCTION DICTATES, THE WIDTH MAY BE REDUCED TO 2-1/8" OR 1-1/2" UNDER SPECIAL CONDITIONS. 3.4 FIXTURE OUTLETS IN CEILINGS (MINIMUM) SHALL BE 4" OC AGONAL X 1-1/2" DEEP (4-11/16" OCTAGONAL X 2-1/2" DEEP WHERE REQUIRED TO ACCOMNDDATE LARGER CONDUIT OR LARGER NUMBER OF WIRES). 3.5 GANG BOXES SHALL BE ONE PIECE (MINIMUM), 2-1/8" DEEP. 3.6 PROVIDE FLUSH FLOOR BOX SERIES 880 BY WIRE MOLD WTH DUPLEX RECEPTACLE FOR WOOD PLATFORM AT DISPLAY SHOW WINDOWS, BOX WITH COVER PLATE FLANGE: CAT. #880W1-817TCAL AND BRUSHED ALUMINUM COVER PLATE: CAT. #828R-TCAL WITH FLIP LID TO PROTECT RECEPTACLE WHEN NOT IN USE. BOTH FLANGE AND COVER PLATE SHALL HAVE BRUSHED ALUMINUM FINISH. UL SCRUB LISTED. 3_7 FLUSH MOUNT BOXES IN ALL FINISHED WALLS, INSTALL THE PLASTER RINGS IN DRY WALLED PLASTERED WALLS AND RAISED COVERS AS REQUIRED IN WALLS WITH OTHER FINISHES SO THAT THE COVER PLATES FIT TIGHTLY AGAINST BOXES OR RINGS. 3/16" MAXIMUM GAPS ARE ALLOWED FOR NONCOMBUSTIBLE WALLS. 3_8 SUPPORT ALL BOXES TO MAINTAIN PROPER ALIGNMENT AND RIGIDITY. DIVISION 16140 - WIRING DEVICES 1.0 WIRING DEVICES 1_1 WIRING DEVICE COLOR SHALL BE WHITE, UNLESS OTHERWISE NOTED. 1.2 PROVIDE TOTALLY ENCLOSED, 20 AMPERE, 120/277 VOLT, QUIET A/C GENERAL USE SNAP SWITCHES. 1.3 SWITCHES SHALL BE SPECIFICATION GRADE AS MANUFACTURED BY HUBBELL, P&S, OR LEMON. 1.4 PROVIDE NEMA CONFIGURATION 5-20R DUPLEX 125 VOLT GROUNDING TYPE RECEPTACLES RATED FOR 20 AMPERES UNLESS OTHERWISE INDICATED ON THE DRAWINGS. 1.5 RECEPTACLES SHALL BE SPECIFICATION GRADE AS MANUFACTURED BY HUBBELL, P&S OR LEVITON. 1_6 RECEPTACLES REQUIRING AMPERAGES, VOLTAGES OR CONFIGURATIONS DIFFERENT FROM THE DUPLEX CONVENIENCE RECEPTACLES ABOVE SHALL BE AS INDICATED ON THE DRAWINGS. 1_7 PROVIDE OTHER RECEPTACLES OF A QUALITY, MATERIAL AND WORKMANSHIP EQUAL TO THAT SPECIFIED FOR DUPLEX CONVENIENCE RECEPTACLES. 1.8 PROVIDE COVER OR DEVICE PLATES FOR OUTLET BOXES AS FOLLOWS UNLESS OTHERWISE NOTED: 1.8a FINISHED AREAS: THERMOPLASTIC -COLOR TO MATCH DEVICE. 1.8b UNFINISHED AREAS: ZINC COATED SHEET METAL, ALUMINUM, OR CAST METAL AS APPROPRIATE FOR THE TYPE OF BOX. 1.8c EXTERIOR AREAS: COPPER FREE ALUMINUM WITH GRAY, POWDER EPDXY FINISH, GASKET, WEATHERPROOF, CROUSE -HINDS "WLRD" FOR DUPLEX RECEPTACLES AND WLRS FOR SINGLE RECEPTACLES OR EQUAL. 1.8d TELEPHONE COMMUNICATIONS, AND SIGNAL OUTLET PLATES, SHALL MATCH THOSE USED FOR RECEPTACLES AND SWITCHES. ALL OUTLET AND/OR JUNCTION BOXES SHALL BE COMPLETE WITH A COVER PLATE BY THIS CONTRACTOR. 1.8e WHERE DEVICES ARE GANGED, THEY SHALL BE INSTALLED UNDER A COMMON COVER PLATE. 1_9 LOCATE THE SWITCHES APPROXIMATELY 4'-0" ABOVE THE FINISHED FLOOR ELEVATION OR NEAREST BLOCK COURSE (WITHIN A.D.A. REQUIREMENTS), UNLESS OTHERWISE INDICATED. THE LONG DIMENSION OF THE SWITCHES SHALL BE VERTICAL. 1.10 LOCATE RECEPTACLES APPROXIMATELY 1'-6" ABOVE THE FINISHED FLOOR ELEVATION OR NEAREST BLOCK COURSE (WITHIN A.D.A. REQUIREMENTS), UNLESS NOTED OTHERWISE THE LONG DIMENSION OF RECEPTACLES SHALL BE VERTICAL. DIVISION 16410 - SAFETY SWITCHES 1.0 SAFETY SWITCHES 1_1 SAFETY SWITCHES SHALL BE THE ENCLOSED HEAVY-DUTY TYPE (TYPE HD) WITH QUICK -MAKE, QUICK -BREAK MECHANISM AND EXTERNAL PAD LOCKABLE OPERATING HANDLE. 1_2 SAFETY SWITCHES SHALL BE RATED FOR 240 OR 600 VOLTS AS APPLICABLE. THEY SHALL BE HORSEPOWER RATED WHEN USED IN MOTOR CIRCUITS. 1_3 SAFETY SWITCHES SHALL BE FUSIBLE OR NON -FUSIBLE 2, 3 OR 4 POLE AS INDICATED ON THE DRAWINGS. 1_4 SAFETY SWITCHES SHALL BE SINGLE THROW UNLESS OTHERWISE INDICATED ON THE DRAWINGS. 1_5 ENCLOSURES SHALL BE NEMA 1 INDOORS AND NEMA 3R OUTDOORS UNLESS OTHERWISE INDICATED ON THE DRAWINGS. 1_6 MANUFACTURER SHALL BE SQUARE D, SEIMENS OR CULTER-HAMMER. 1_7 MOUNT THE SAFETY SWITCHES SECURELY BETWEEN TX 6' LEVELS ABOVE THE FLOOR UNLESS OTHERWISE INDICATED ON THE DRAWINGS. 1_8 MOUNT THE SAFETY SWITCHES SECURELY BETWEEN TX T LEVELS ABOVE THE FLOOR UNLESS OTHERWISE INDICATED ON THE DRAWINGS. 1_9 SWITCHES ON BLOCK WALLS SHALL BE MOUNTED ON A 3/4" PLYWOOD BACKBOARD, WHERE LOCATED INDOORS. DIVISION 16420 -MOTOR STARTERS 1.0 MOTOR STARTERS 1_1 PROVIDE MOTOR STARTERS (MAGNETIC OR FUSED COMBINATION) AND CONTROL EQUIPMENT WHERE SHOWN. STARTERS SHALL BE PROVIDED WITH 120 VOLT COILS, 3 OVERLOADS, CONTROL TRANSFORMER WITH FUSED 120 VOLT SECONDARY CONTROL CIRCUIT, (2) N.O. AND (2) N.C. AUXILIARY CONTACTS, HAND -OFF -AUTO SELECTOR SWITCH AND RUNNING PILOT LIGHT, UNLESS OTHERWISE NOTED. WIRE THRU CONTROL DEVICES FURNISHED BY OTHER TRADES. SINCE MOTOR DRIVEN EQUIPMENT IS FURNISHED BY OTHER TRADES, THE CONTROL INDICATED ON THE DRAWINGS SHALL BE CONSIDERED AS FOR BIDDING PURPOSES ONLY. WIRE TO CONFORM TO THE ACTUAL EQUIPMENT SUPPLIED AND INSTALLED BY THE OTHER TRADES. ALL FUSES SHALL BE DUAL ELEMENT TYPE. PROVIDE "BLOWN FUSE" INDICATOR LAMPS IN COVER. 1_2 STARTERS SHALL BE SQUARE D, SEIMENS OR CUTLER -HAMMER. 1_3 THE EXACT NUMBER OF NORMALLY OPEN AND NORMALLY CLOSED AUXILIARY CONTACTS IN EACH STARTER SHALL BE DETERMINED BY THE TEMPERATURE CONTROL AND/OR FIRE ALARM CONTRACTOR. i 1.0 LIGHTING CONTROL SYSTEM 1_1 GENERAL INTRODUCTION: THE WORK COVERED IN THIS SECTION IS SUBJECT TO ALL THE REQUIREMENTS IN THE GENERAL CONDITIONS OF THE SPECIFICATIONS. THE CONTRACTOR SHALL COORDINATE ALL OF THE WORK IN THIS SECTION WITH ALL OF THE TRADES COVERED IN OTHER SECTIONS OF THE SPECIFICATION TO PROVIDE A COMPLETE AND OPERABLE SYSTEM. 1.2 DESCRIPTION OF THE WORK: 1.2a THE EXTENT OF THE LIGHTING CONTROL SYSTEM WORK IS INDICATED BY THE DRAWINGS AND BY THE REQUIREMENTS OF THIS SECTION. IT IS DEFINED TO INCLUDE, BUT NOT BY WAY OF LIMITATION: 1.2a1 PANELBOARDS CONTAINING INTEGRAL CONTACTORS. 1.2a2 CONTROL ELECTRONICS FOR CONTACTORS AND TIMECLOCKS AND MONITORING THE STATUS OF THE SYSTEM. 1.20 ASSOCIATED LOW AND LINE VOLTAGE OVERRIDE SWITCHES AND LIGHT SENSORS. 1.2a4 TIMECLOCKS, CONTACTORS. 1.2a5 ANY WORK STATIONS, SOFTWARE AND COMMUNICATIONS HARDWARE. 1.2b SYSTEM INSTALLATION INCLUDES THE FOLLOWING: 1.2b1 WIRING OF BRANCH CIRCUIT CONDUCTORS AND CONTACTORS 1.2b2 INSTALLATION OF EXTERNAL CONTROL DEVICES AND WIRING TO THE CONTROLLER. 1.2b3 INSTALLATION OF COMMUNICATIONS CONDUCTORS AND ASSOCIATED HARDWARE. 1_3 WARRANTY: MANUFACTURER SHALL WARRANT SPECIFIED EQUIPMENT TO BE FREE FROM DEFECTS IN MATERIALS AND WORKMANSHIP FOR AT LEAST ONE YEAR FROM THE DATE OF INSTALLATION OR EIGHTEEN MONTHS FROM DATE OF PURCHASE. 2.0 PANELBOARDS 2_1 ACCEPTABLE MANUFACTURERS: SQUARED CUTLER HAMMER SEIMENS G.E. FOR PRICING AND ORDERING INFORMATION PROVIDE EQUIPMENT AS SPECIFIED HEREIN NO SUBSTITUTIONS PERMITTED. CONTRACTOR SHALL CONTACT NO LATER THAN 5 DAYS AFTER JOB IS AWARDED TO ENSURE LEAD TIMES DO NOT AFFECT PROJECT SCHEDULE. PANELBOARDS SHALL BE ENCLOSED DEAD FRONT SAFETY TYPE WITH FEATURES AND RATINGS AS SCHEDULED ON THE DRAWINGS. 2_2 PANELS KNOWN AS "LOAD CENTERS" ARE UNACCEPTABLE. 2_3 MOLDED CASE CIRCUIT BREAKERS SHALL BE AS SCHEDULED ON THE DRAWINGS AND SPECIFIED IN THIS DIVISION. 2.4 ALL BUS BARS SHALL BE RECTANGULAR, SOLID COPPER. 2_5 SPACE, WHERE SHOWN IN PANEL SCHEDULES, DESIGNATES SPACE FOR FUTURE PROTECTIVE DEVICES AND SHALL INCLUDE BUS AND SUPPORT. 2.6 INSTALL CABINETS SO THAT CENTER OF THE TOP BREAKER DOES NOT EXCEED 6'-6" ABOVE THE FINISHED FLOOR. 2_7 ENTRIES ON DIRECTORY CARDS SHALL BE TYPED, COMPLETE AND ACCURATE. 2_8 ALL BOLTED CONNECTIONS SHALL BE TORQUED IN ACCORDANCE WITH MANUFACTURER'S STANDARDS. 2_9 ELECTRICAL CONTRACTOR SHALL ARRANGE CIRCUITS AS NEAR AS POSSIBLE TO CIRCUIT NUMBERS ON THE DRAWINGS. AT COMPLETION OF JOB, ELECTRICAL CONTRACTOR SHALL TAKE CURRENT READING CHECKS OF RESPECTIVE PHASES. A MINIMUM OF CIRCUIT CONNECTIONS SHALL BE REARRANGED TO BALANCE AS CLOSELY AS POSSIBLE, THE LOAD IN THE PANEL. 2.10 ALL BREAKERS SHALL BE BOLT -ON TYPE. 2.11 PROVIDE (3) SPARE 1" CONDUITS INTO ACCESSIBLE CEILING SPACE WHERE PANELS ARE FLUSH -MOUNTED. 3.0 DISTRIBUTION PANELS 3.1 ACCEPTABLE MANUFACTURERS: SQUARE D. CUTLER HAMMER, SEIMENS. G.E.. FOR PRICING AND ORDERING INFORMATION, PROVIDE EQUIPMENT AS SPECIFIED HEREIN, NO SUBSTITUTIONS PERMITTED. CONTRACTOR SHALL CONTACT NO LATER THAN 5 DAYS AFTER JOB IS AWARDED TO ENSURE LEAD TIMES DO NOT AFFECT PROJECT SCHEDULE. DISTRIBUTION PANELS SHALL BE DEAD FRONT TYPE WITH FEATURES AND RATING AS SCHEDULED ON THE DRAWINGS. 3_2 MOLDED CASE CIRCUIT BREAKERS SHALL BE AS SCHEDULED, OF SIZE AND NUMBER INDICATED ON THE DRAWINGS. ALL BREAKERS SHALL BE BOLT -ON TYPE. 3_3 ALL LUGS SHALL BE UL APPROVED CU/AL TYPE. 3_4 PANELS SHALL BE MANUFACTURED AS A COMPLETE UNIT AND NOT AN ASSEMBLY OF PARTS SECURED FROM A SUPPLY HOUSE. 3_5 ALL PANELS SHALL BE CAPABLE OF ACCEPTING CIRCUIT BREAKERS SIZED UP TO AND INCLUDING 400 AMPS. 3_6 VERTICAL BUSSING SHALL BE EXTENDED THE FULL LENGTH OF THE PANEL. 3_7 ALL BUS BARS SHALL BE RECTANGULAR SOLID COPPER. 3_8 DISTRIBUTION PANELS SHALL BE SQUARE D. 3_9 INSTALL PANELS SUCH THAT HANDLE FOR THE TOP BREAKER DOES NOT EXCEED 6'-6" ABOVE FINISHED FLOOR. 3.10 PROVIDE PHENOLIC LABELS FOR EACH PANEL. 3.11 ALL BOLTED CONNECTIONS SHALL BE TORQUED IN ACCORDANCE WITH MANUFACTURER'S STANDARDS. 3.12 SURFACE -MOUNTED PANELS SHALL BE MOUNTED ON A 3/4" PLYWOOD BACKBOARD. FLOOR -MOUNTED PANELS SHALL BE MOUNTED ON A 4" HIGH CONCRETE PAD. DIVISION 16461 - DRY TYPE TRANSFORMERS 1.0 TRANSFORMERS 1_1 TRANSFORMERS SHALL BE CONTINUOUSLY RATED ISOLATING TYPE FOR 60 HERTZ SERVICE UNLESS OTHERWISE INDICATED. 1_2 INSULATION SYSTEMS SHALL BE 220 DEGREES C (150 DEGREES RISE). 1_3 ENCLOSURES FOR TRANSFORMERS SHALL BE METALLIC, SUITABLE FOR INDOOR AND OUTDOOR INSTALLATION AS APPLICABLE AND RODENT PROOF. 1_4 MANUFACTURERS SHALL BE SQUARE D. FRACTIONAL KVA TRANSFORMERS SHALL BE MANUFACTURED BY EDWARDS OR THE SPECIAL EQUIPMENT MANUFACTURER IN WHICH THE TRANSFORMERS ARE USED. 1_5 FOUR APPROVED VIBRATION DAMPENERS PER TRANSFORMER SHALL BE EMPLOYED AS NECESSARY TO AVOID TRANSMITTING ANY VIBRATION TO THE BUILDING STRUCTURE. SIZES OF THE MOUNTINGS SHALL BE SELECTED ON THE BASIS OF THE WEIGHT OF THE TRANSFORMER, USING: 1.5a A MINIMUM 1" THICK RUBBER -CORK -RUBBER SANDWICH TYPE FOR FLOOR MOUNTING. 1.5b A SPRING TYPE FOR SUSPENSION MOUNTING. 1.5c TWO(2) SPRING TYPE AT THE TOP (WITH TWO (2) STEEL BRACKETS) AND TWO (2) RUBBER -IN COMPRESSION TYPE AT THE BOTTOM (STAND-OFF) FOR WALL MOUNTING. COMP I i NFPA '70 o NE( SEP 14 2016 ISSUE DATE LO co 'SU) rU)r y N (L XON o ~ixn t` �o EGO m r>> � CO LO m aC (0 V) (9 n - two City of Tukwila BUILDING DIVISION RECEIVED CITY OF TUKWILA SEP 08 2016 PERMIT CENTER P7. S x y P )7 These drawings/spectfications are the property of Kamus + Keller. They are fumished as contract documents only. The seal(s) and signature(s) appy only to the documents to which they affixed, and expressly displaim any responsibility for all other plans, specifications, estimates, reports or other documents or instruments relating to or intended to be used for any part or parts of the architectural or engineering project. Additionally these drawings and seal(s) shall in no way convey or imply any time of warranty or certification retating to the performance of products and materials beyond those provided by their respective manufacturer. III PROJECT NO. 16.0430.01 DRAWN/REVIEWED GFIBB VIII II III III II I DATEIISSUE 8.31.2016 SHEET TITLE ELECTRICAL SPECIFICATIONS II I II III IIII SHEET NO. E1.1 r M W W J 0<c�T- 00 00J 1- rC < co ry C ry UJ Q W I- W S' <UJ 7w =U~ 06W 1-oZ)v <w0 C) 00 N City of Tukwila BUILDING DIVISION RECEIVED CITY OF TUKWILA SEP 08 2016 PERMIT CENTER P7. S x y P )7 These drawings/spectfications are the property of Kamus + Keller. They are fumished as contract documents only. The seal(s) and signature(s) appy only to the documents to which they affixed, and expressly displaim any responsibility for all other plans, specifications, estimates, reports or other documents or instruments relating to or intended to be used for any part or parts of the architectural or engineering project. Additionally these drawings and seal(s) shall in no way convey or imply any time of warranty or certification retating to the performance of products and materials beyond those provided by their respective manufacturer. III PROJECT NO. 16.0430.01 DRAWN/REVIEWED GFIBB VIII II III III II I DATEIISSUE 8.31.2016 SHEET TITLE ELECTRICAL SPECIFICATIONS II I II III IIII SHEET NO. E1.1 GENERAL NOTES 1. ELECTRICAL CONTRACTOR SHALL FIELD VERIFY ALL EXISTING CONDITIONS PRIOR TO BASE BID. IN CASE OF ANY DISCREPANCIES WITH EXISTING FIELD CONDITIONS, ELECTRICAL CONTRACTOR SHALL VERIFY THE EXACT DIFFERENCE FOR POSSIBLE REVISIONS TO THIS DOCUMENT. 2. INSTALL RECESSED LUMINAIRES USING ACCESSORIES AND FIRE STOPPING MATERIALS TO MEET REGULATORY REQUIREMENTS FOR FIRE RATING. 3. LIGHT SWITCHES ARE TO BE MOUNTED AT 42" AFF (UNLESS OTHERWISE NOTED). 4. LIGHT FIXTURES ARE TO BE CENTERED ON CEILING TILES (UNLESS OTHERWISE NOTED). 5. CONTACT ARCHITECT TO COORDINATE LIGHT FIXTURE LOCATIONS IF EXISTING CEILING GRID IS TO BE REUSED. 6. PROVIDE MINIMUM 90 MIN BATTERY PACKS IN EMERGENCY FIXTURES, WHERE INDICATED ON THE DRAWINGS. 7. ELECTRICAL CONTRACTOR SHALL COORDINATE WITH GENERAL CONTRACTOR AND TENANT REPRESENTATIVE FOR ORDERING LUMINAIRES FROM TENANTS NATIONAL ACCOUNT WITH "GRAINGER". 8. PROVIDE BLACK ADHESIVE LABEL ADHERED TO ALL SWITCHED RECEPTACLES WITH 1/4" LETTERING INDICATING "SWITCHED FOR LIGHTING". 9. COORDINATE TIMING OF TIMECLOCK WITH STORE MANAGER. 10. ON ALL MULTI -WIRED HOMERUN CIRCUIT BREAKERS (REFER TO PLANS) CONTRACTOR SHALL FIELD INSTALL ON MULTI -USE CIRCUIT BREAKERS AN APPROVED HANDLE TIE PER NEC. 11. ALL EQUIPMENT SHALL BE LISTED BY A NATIONALLY RECOGNIZED TESTING LABORATORY. 12. IT IS ACCEPTABLE TO USE MIC CABLE FOR BRANCH CIRCUITS OR HOMERUNS PROVIDED IT COMPLIES WITH AUTHORITY HAVING JURISDICTION, LOCAL RECOGNIZED CODE AND LANDLORD. VERIFY PRIOR TO BID. 13. ALL LOW VOLTAGE WIRING TO BE IN CONDUIT UNLESS OTHERWISE APPROVED BY AUTHORITY HAVING JURISDICTION NOTES BY SYMBOL ONUMBER INDICATES CIRCUIT COORDINATION, LETTER INDICATES SWITCH COORDINATION. REFER TO LIGHTING CONTROL DETAIL ON SHEET E1.0. OALL EMERGENCY/EXIT FIXTURES ARE TO BE PROVIDED WITH MINIMUM 90 MIN EMERGENCY BATTERY BACK-UP AND CONNECTED TO UNSWITCHED LEG OF LOCAL CIRCUIT. BY=PASS ENERGY MANAGEMENT SYSTEM WHERE REQUIRED). OALL LIGHTING CIRCUITS INDICATED ON PLANS SHALL BE ROUTED THROUGH THE LIGHTING CONTROL SYSTEM. REFER TO LIGHTING LIGHTING CONTROL DIAGRAM ON SHEET E1.0 FOR ADDITIONAL INFORMATION. 4OSWITCHBANK LOCATION. REFER TO SWITCHBANK DETAIL ON THIS SHEET AND LIGHTING CONTROL DIAGRAM ON SHEET E1.0 FOR ADDITIONAL INFORMATION. OELECTRICAL DISTRIBUTION EQUIPMENT. REFER TO SHEET E3.0 FOR FURTHER COORDINAT OEXISTING BOH LIGHTING AND SWITCHING TO REMAIN. RE -LAMP, REPAIR, RE -BALLAST AS NEEDED TO PROVIDE FULLY FUNCTIONING FIXTURES 7O CONNECT TO EXISTING BOH CIRCUIT AND SWITCHING. V.I.F. SWITCHBANK DETAIL 'a' �b� �'d' >- Y Q Q U Wz N 0 t7 O NOTE: SWITCH CONTROL LOCATION. REFER TO SHEET E1.0 LIGHTING CONTROL DETAIL FOR NUMBER OF POLES REQUIRED. SWITCHES SHALL BE INSTALLED BETWEEN STUDS. MAKE (MORE) ROWS IF NECESSARY. DO NOT CUT STUDS TO ACCOMMODATE A SINGLE ROW OF SWITCHES. ALL CONTROL DEVICES FOR LIGHT, POWER, HEAT, ALARMS, ETC. SHALL BE MOUNTED NO HIGHER THAN 42" FROM THE FLOOR. IMPORTANT: T.G.C. SHALL CONNECT EMERGENCY/NIGHT LIGHTING TO LOCAL CIRCUIT ON UNSWITCHED LEG. SCALE: 1/4"=l' -O" REVIEWED RUH' COMPLIANCE , .J e A,H NFPA70 - NEC SEP 14 2016 City of TuWla BUILDING DIVISION A)1rrff11 A w• • • w• • w•�� SEP 08 2016 PERMIT CENTER ISSUE DATE C- � r-nOD co N r � 0 ~r aO m N C) m Q. � �� 9 mfnc0(LLL These dreviings/specifications are the property of Kamus + Keller. They are fumished as contract documents only. The seal(s) and signature(s) apply only to the documents to which they affixed, and expressly displaim any responsibility for all other plans, specifications, estimates, reports or other documents or instruments relating to or Intended to be used for any part or parts of the architectural or engineering project. Additionally these drawings and seal(s) shaft in no way convey or imply any time of warranty or certification relating to the performance of products and materials beyond those provided by their respective manufacturer. PROJECT NO. 16.0430.01 DRAWN/REVIEWED GFIBB DATE/ISSUE 8.31.2016 SHEET TITLE ELECTRICAL LIGHTING PLAN SHEET NO. E2.0 r M W F_ UJ (! U) _jry 0 Q QD 0) Q wW < w UJ _J Q 06 own <U)0 U) 0 00 N These dreviings/specifications are the property of Kamus + Keller. They are fumished as contract documents only. The seal(s) and signature(s) apply only to the documents to which they affixed, and expressly displaim any responsibility for all other plans, specifications, estimates, reports or other documents or instruments relating to or Intended to be used for any part or parts of the architectural or engineering project. Additionally these drawings and seal(s) shaft in no way convey or imply any time of warranty or certification relating to the performance of products and materials beyond those provided by their respective manufacturer. PROJECT NO. 16.0430.01 DRAWN/REVIEWED GFIBB DATE/ISSUE 8.31.2016 SHEET TITLE ELECTRICAL LIGHTING PLAN SHEET NO. E2.0 GENERAL NOTES 1. ELECTRICAL CONTRACTOR SHALL FIELD VERIFY ALL EXISTING CONDITIONS PRIOR TO BASE BID. IN CASE OF ANY DISCREPANCIES WITH EXISTING FIELD CONDITIONS, ELECTRICAL CONTRACTOR SHALL VERIFY THE EXACT DIFFERENCE FOR POSSIBLE REVISIONS TO THIS DOCUMENT. 2. INSTALL RECESSED LUMINAIRES USING ACCESSORIES AND FIRE STOPPING MATERIALS TO MEET REGULATORY REQUIREMENTS FOR FIRE RATING. 3. LIGHT SWITCHES ARE TO BE MOUNTED AT 42" AFF (UNLESS OTHERWISE NOTED). 4. LIGHT FIXTURES ARE TO BE CENTERED ON CEILING TILES (UNLESS OTHERWISE NOTED). 5. CONTACT ARCHITECT TO COORDINATE LIGHT FIXTURE LOCATIONS IF EXISTING CEILING GRID IS TO BE REUSED. 6. PROVIDE MINIMUM 90 MIN BATTERY PACKS IN EMERGENCY FIXTURES, WHERE INDICATED ON THE DRAWINGS. 7. ELECTRICAL CONTRACTOR SHALL COORDINATE WITH GENERAL CONTRACTOR AND TENANT REPRESENTATIVE FOR ORDERING LUMINAIRES FROM TENANTS NATIONAL ACCOUNT WITH "GRAINGER". 8. PROVIDE BLACK ADHESIVE LABEL ADHERED TO ALL SWITCHED RECEPTACLES WITH 1/4" LETTERING INDICATING "SWITCHED FOR LIGHTING". 9. COORDINATE TIMING OF TIMECLOCK WITH STORE MANAGER. 10. ON ALL MULTI -WIRED HOMERUN CIRCUIT BREAKERS (REFER TO PLANS) CONTRACTOR SHALL FIELD INSTALL ON MULTI -USE CIRCUIT BREAKERS AN APPROVED HANDLE TIE PER NEC. 11. ALL EQUIPMENT SHALL BE LISTED BY A NATIONALLY RECOGNIZED TESTING LABORATORY. 12. IT IS ACCEPTABLE TO USE M/C CABLE FOR BRANCH CIRCUITS OR HOMERUNS PROVIDED IT COMPLIES WITH AUTHORITY HAVING JURISDICTION, LOCAL RECOGNIZED CODE AND LANDLORD. VERIFY PRIOR TO BID. 13. ALL LOW VOLTAGE WIRING TO BE IN CONDUIT UNLESS OTHERWISE APPROVED BY AUTHORITY HAVING JURISDICTION NOTES BY SYMBOL ONUMBER INDICATES CIRCUIT COORDINATION, LETTER INDICATES SWITCH COORDINATION. ALL MVU LIGHTING CIRCUITS SHALL BE ROUTED THROUGH ENERGY MANAGEMENT SYSTEM. REFEF TO LIGHTING CONTROL DETAIL ON SHEET E1.0 OELECTRICAL CONTRACTOR TO COORDINATE WITH TELEPHONE/DATA SYSTEM INSTALLER CONDUIT SIZE, REQUIREMENTS AND ROUTING OF TEUDATA CONDUIT IN FIELD PRIOR TO ROUGH -IN. OELECTRICAL CONTRACTOR SHALL COORDINATE WITH ARCHITECTURAL MILLWORK DETAILS FOR FINAL LOCATION OF ALL DEVICES AND TEUDATA CONDUIT AT MILLWORK. INCLUDE ALL J -BOXES, TWO CHANNEL WIREMOLDS AND REQUIRED CONDUITS FOR LINE AND LOW VOLTAGE AS PART OF BASE BID IN ORDER TO OBTAIN A COMPLETE AND OPERATING SYSTEM. OPROVIDE FLUSH FLOOR MOUNTED POWER AND TEUDATA DEVICE AT LOCATION INDICATED ON THE PLANS. PROVIDE FLOOR BOX AND CORRESPONDING ACCESSORIES REQUIRED PER FIELD CONDITIONS (BLACK COVER FOR CARPET FLOORING AND BRASS COVER FOR ALL OTHER FINISHES. O5 CORE FLOOR FOR INSTALLATION OF NEW CONDUITS. PROVIDE CONDUIT AS SHOWN WITH PULL STRING FOR DATA CABLING AND 3/4" CONDUIT WITH POWER WIRING TO FLOOR BOX RECEPTACLES. FIELD VERIFY ROUTING OF CONDUIT PRIOR TO CUTTING FLOOR. PATCH TO MATCH EXISTING. COORDINATE WITH FURNITURE SUPPLIER AND ARCHITECTURAL DIMENSION PLAN PRIOR TO SAW -CUTTING FLOOR. ALL FLOOR MOUNTED DEVICES MUST MEET "SCRUB WATER TEST'. OAT THIS LOCATION, STUB CONDUITS UP THROUGH WALL. ALL TEUDATA CONDUITS SHALL BE STUBBED INTO ACCESSIBLE CEILING SPACE ABOVE. FINAL PLACEMENT OF CONDUITS STUB -UP AT FLOOR SHALL BE COORDINATED WITH TENANT REPRESENTATIVE PRIOR TO INSTALLATION OELECTRICAL CONTRACTOR SHALL PROVIDE DUAL BRANCH CIRCUIT QUAD RECEPTACLES BEHIND MVU. HALF OF QUAD FOR GENERAL POWER AND HALF FOR SWITCHING. REFER TO GENERAL NOTES 8 AND 10 ABOVE. OELECTRICAL DISTRIBUTION EQUIPMENT. REFER TO SHEET E3.0 FOR FURTHER COORDINATION. OELECTRICAL CONTRACTOR TO MAKE FINAL CONNECTION TO TENANT SIGN. IF NOT EXISTING, PROVIDE MEANS OF DISCONNECT AND SEPARATE GROUND PER NEC (CONDUIT GROUND NOT PERMITTED). CIRCUIT SIGN VIA TIMECLOCK, REFER TO LIGHTING CONTROL DIAGRAM ON SHEET E1.0. 10 PROVIDE 24"w x 36"h x 6"d TELEPHONE CABINET, 3/4" THICK FIRE RETARDANT PLYWOOD. PAINT EXPOSED SIDE WITH ADJACENT WALL COLOR. PROVIDE GROUND BUS, 3/4" CONDUIT WITH (1) #6 GROUND TO LIFER GROUND. PROVIDE QUAD RECEPTACLE AND CIRCUIT AS INDICATED. 11 EXISTING MEANS OF DISCONNECT AND ALL ASSOCIATED ELECTRICAL FOR WATER HEATER TO REMAIN 12 EXISTING NON-FUSED DISCONNECT, WP/GF) RECEPTACLE, AND DUCT MOUNTED SMOKE DETECTOR TO REMAIN. REFER TO PANEL SCHEDULE AND RISER DIAGRAM ON SHEET E3.0 ADDITIONAL INFORMATION. V.I.F. 13 EXISTING RECEPTACLE TO REMAIN 14 PROVIDE POWER AND KEYED SWITCHES FOR ROLLING GRILLE. COORDINATE SPEC AND FINAL' SWITCH LOCATIONS WITH ARCHITECT 15 EXISTING T -STATS TO REMAIN WIN (E) I L SH I 42 L 26 X60" Lit 10 24 I L � 34 I i(TYPICAL) QMI L L 23 20,22 IC3 31,33 mC �mL�3� 1 I _ , EAR fA!LUE-T 18 MI MWU MWU FSLS ' c� .J� 5 (TYPICAL) AHU-1 12 2L 7/29 (TYPICAL) AATV-BENCH AHU-2 L 12 19,21 L CU -2 CU -1 12 12 L L 36/38/40 28/30 MWU i, , Ems:_ :.. LT -S 2 M — — — 20 LT -D CLG LT -S (TYPICAL) MWU L 31,3. a m '-SLT-C T -D 22 LT -ADA --S LT -C (TYPICAL) (TYPICAL) MWU MWU SPT1- 4 19 c _ 1 3 i■' 1 fir' ,.A4,4U, 11 i � ■!_ ■ � SCALE: 1/4"=I'-0" MWU BP L 12 D 12 MPOS L � i17 NOTE: A FIRE ALARM SYSTEM IS REQUIRED FOR THIS LOCATION. T.G.C. TO HIRE A LANDLORD APPROVED FIRE PROTECTION CONTRACTOR TO PROVIDE FIRE PROTECTION PLANS UNDER A SEPERATE SUBMITTAL. RS MWU MWU Ell- � i�-alp (2)D V CLG JE® AWILA 2016 :ENTER ISSUE DATE mco I- m a ; 00 : F-7 j CL mrN m oco m M N m �j C Lr � � P='� (o U) a tL L N O C C Q) C U) C O U ■ C C N O- C O a These drawings/specifications are the property of Kamus + Keller. They are furnished as contract documents only. The seal(s) and signature(s) appy only to the documents to which they affixed, and expressly displatm any responsibility for all other plans, spectfications, estimates, reports or other documents or instruments relating to or intended to be used for any part or parts of the architectural or engineering project. Additionally these drawings and seal(s) shall in no way convey or Imply any time of warranty or certification relating to the performance of products and materials beyond those provided by their respective manufacturer. PROJECT NO. 16.0430.01 DRAWN/REVIEWED GF1BB DATEIISSUE 8.31.2016 SHEET TITLE ELECTRICAL POWER PLAN SHEET NO. E2.1 Cfl M W UJ U) Octc G Jarmo 0 Q WI— W S� �CWzW W =W06 � D <C 0 to (n 0 W 0 00N These drawings/specifications are the property of Kamus + Keller. They are furnished as contract documents only. The seal(s) and signature(s) appy only to the documents to which they affixed, and expressly displatm any responsibility for all other plans, spectfications, estimates, reports or other documents or instruments relating to or intended to be used for any part or parts of the architectural or engineering project. Additionally these drawings and seal(s) shall in no way convey or Imply any time of warranty or certification relating to the performance of products and materials beyond those provided by their respective manufacturer. PROJECT NO. 16.0430.01 DRAWN/REVIEWED GF1BB DATEIISSUE 8.31.2016 SHEET TITLE ELECTRICAL POWER PLAN SHEET NO. E2.1 U) 0 Z v ii W W MOTES BY SYMBOL LI+7-2LBCW--4'—' (3)D (1)T — — — t" CONDUIT FOR POWER PER TABLE. 1" CONDUIT FOR DATA PER TABLE. 2" CONDUIT FOR (1) HDMI„ (2) USB, PER TABLE 0 EXISTING METER BASE AND METER SOCKET TO REMAIN. 0 EXISTING 200 AMP BREAKER TO REMAIN. OEXISTING (4) #3/0 THWN CU, (1) #4 GROUND IN EXISTING CONDUIT TO REMAIN. 4O EXISTING CONDUIT COMPLETE WITH PULL STRING FOR TELEPHONE SERVICE FROM LANDLORD DMARC STUBBED INTO TENANT SPACE. INTERCEPT AND ROUTE CONDUIT TO TENANT PHONE BOARD LOCATION. OEXISTING 60 AMP NON-FUSED DISCONNECT TO REMAIN OEXISTING 30 AMP NON-FUSED DISCONNECT TO REMAIN OEXISTING (2) #8 THWN CU (1) #10 GROUND IN EXISTING CONDUIT OEXISTING (3) #10 THWN CU (1) #10 GROUND IN EXISTING CONDUIT OEXISTING (2) #12 THWN CU (1) #10 GROUND IN EXISTING CONDUIT W REF. WIREMOLD I -1 wLIJ 2" CONDUIT STUB -UP BEHIND FIXTURE (OUTSIDE OF WALL), FLUSH WITH CONCRETE I ` = t .EGIRAND RFB4E 2,CONDUIT STgB-UP NEXT TO LOOR BOX, PE TABLE GENERAL NOTES 1. 120/208 VOLT 4 WIRE EXISTING ELECTRICAL SERVICE NOTE: RECEPTACLES @ BACKWRAP AND LEARNING TABLE TO BE ON A SINGLE 20 AMP DEDICATED CIRCUIT. DO NOT ADD OTHER RECEPTACLES TO CIRC. NOTE: IF LEARNING TABLES ARE TO BE TEMPORARILY USED AS POS STATIONS, THE 2" CONDUIT SHOWN IN ENLARGED PLAN IS REQUIRED IN ORDER TO PROVIDE HDMI AND USB CORDS AND AMPLIFIER FROM THE BACKWRAP TO THE LEARNING TABLE. THE HDMI, USB, AND AMPLIFIER SHOUDL BE ORDERED THROUGH GRAINGER AS REQUIRED. POWER/ DATA ENLARGED PLAN @ BCW & LT CU -1—M5 I CU-2� 7 8 AHU-1 II I 7 AHU-2 I II 119 III TC I EXISTING PANEL i Cl I I L ----J Ifl JAM!"', I Imo; 14+4 5r• i 2. TENANTS GENERAL CONTRACTOR SHALL PROVIDE AND INSTALL ALL COPPER CONDUCTORS WHEN NEW IS REQUIRED 3. VERIFY ALL EXISTING CONDITIONS IN FIELD. ALL UPGRADES REQUIRED BY CODES, LANDLORD OR TENANT SHALL BE BY TENANT AT TENANTS EXPENSE. 4. CONTRACTOR TO VERIFY ALL METERING REQUIREMENTS WITH LANDLORD AND LOCAL UTILITY PRIOR TO BID. 5. CONTRACTOR TO VERIFY EXACT DISTANCE AND ROUTING OF SERVICE FEEDERS FROM LANDLORD DISTRIBUTION/ SERVICE EQUIPMENT TO TENANT SPACE PRIOR TO BIDDING. HOMERUNS AND BRANCH WIRING FOR 20 AMP CIRCUITS SHALL ELECTRICAL LOAD BE AS FOLLOWS: LENGTH CIRCUIT WIRE SIZE HOMERUN WIRE SIZE 1 FT TO 50FT NO.12 AWG NO.12 AWG 51 FT TO 75FT NO.12 AWG NO.10 AWG 76FT TO 120FT NO.10 AWG NO.8 AWG 121 FT TO 190FT NO.10 AWG NO.6 AWG 191 FT TO 30OFT NO.10 AWG NOA AWG SCALE: N.T.S. NOTE REGARDING EXAMINATION OF PREMISES/FIELD CONDITIONS: PRIOR TO SUBMITTING PROPOSALS FOR THE WORK, EACH BIDDER IS REQUIRED TO HAVE EXAMINED THE PREMISES AND VERIFY THE EXISTING FIELD CONDITIONS. THE EXISTING CONDITIONS HAVE BEEN EXAMINED IN THE FIELD BY TENANT REPRESENTATIVE'S AND ARE BELIEVED TO BE DEPICTED IN A ACCURATE MANNER AS THEY EXIST. IF THE BIDDER FINDS THAT THAT THERE ARE DISCREPANCIES BETWEEN THE EXISTING CONDITIONS AND THE INFORMATION SHOWN ON THESE DRAWINGS, THEY SHOULD NOTIFY THE TENANTS REPRESENTATIVE OF THOSE DISCREPANCIES. IF THESE INSTRUCTIONS ARE IGNORED, THE CONTRACTOR SHALL BE RESPONSIBLE FOR FURNISHING ALL THE EQUIPMENT REQUIRED FOR A COMPLETE AND FUNCTIONING ELECTRICAL SYSTEM AT NO ADDITIONAL COST TO TENANT. NOTE REGARDING ELECTRICAL DISTRIBUTION SYSTEM: THE ELECTRICAL RISER DIAGRAM INDICATED HAS BEEN PROPERLY DESIGNED TO ACCOMMODATE TENANTS POWER REQUIREMENTS AND MEETS ALL APPLICABLE BUILDING CODES. IT IS THE RESPONSIBILITY OF THE G.C. TO VERIFY ALL EXISTING CONDITIONS AND DETERMINE IF ANY EXISTING EQUIPMENT AND WIRING IS SUITABLE FOR REUSE IN THE SYSTEM PRIOR TO BIDDING. G.C. SHALL PERFORM ALL WORK NECESSARY TO RESULT IN A COMPLETE AND LEGAL INSTALLATION INCLUDING THE UPGRADING AND/OR MODIFICATION OF THE EXISTING SERVICE FEEDERS, CONDUITS AND TAP -INS EXTENDED TO PROPER POINT OF ORIGIN AS COORDINATED WITH THE LANDLORD. NOTES: I TOTAL AMPS @1201208V 3PH 128.24 1. 100% OF FIRST 10,000 WATTS, PLUS. 50% OF REMAINING LOAD. 2. 100% OF A/C LOAD (COOLING VS HEATING) PLUS 25% OF LARGEST MOTOR. REVIEWED FOR COMPLIANCE 1 'ITH NFPA 7n A NEC SEP 14: 2016 City of-T'ukWl1a BUILDING DIVISInN RECEIVED CITY OF TUKWILA SEP 0 8 2016 PERMIT CENTER ISSUE DATE T S Sr r 00 T ti C 0 r rN' CL o C 00 m CO m 9 C m ur):n) > Lo�� L ai CZ c a� t» r_ 0 0 c c cv CL C 0 ELECTRICAL LOAD S MMA■ iY 1201208V 3PH - 4W LOAD DESCRIPTION CONNECTED VA FACTOR DEMAND VA VOLTAGE PHASE LIGHTING 4,537 1.25 5,671 120 1 RECEPTACLES 9,280 NOTE # 1 9,280 120 1 SHOW WINDOW RECEPTACLE: 0 1.25 0 120 1 MECHANICAL 23,984 NOTE # 2 24,715 208 3 SIGN LIGHTING 1,200 1.25 1,500 120 1 WATER HEATERS 31600 1.25 4,500 120 1 MISCELLANEOUS 500 1.00. 500 120 1 TOTAL 43,101 46,166 208 3 NOTES: I TOTAL AMPS @1201208V 3PH 128.24 1. 100% OF FIRST 10,000 WATTS, PLUS. 50% OF REMAINING LOAD. 2. 100% OF A/C LOAD (COOLING VS HEATING) PLUS 25% OF LARGEST MOTOR. REVIEWED FOR COMPLIANCE 1 'ITH NFPA 7n A NEC SEP 14: 2016 City of-T'ukWl1a BUILDING DIVISInN RECEIVED CITY OF TUKWILA SEP 0 8 2016 PERMIT CENTER ISSUE DATE T S Sr r 00 T ti C 0 r rN' CL o C 00 m CO m 9 C m ur):n) > Lo�� L ai CZ c a� t» r_ 0 0 c c cv CL C 0 These drawings/specifications are the property of Kamus + Keller. They are furnished as contract documents only. The seal(s) and signature(s) apply only to the documents to which they affixed, and expressly dispiaim any responsibility for all other plans, specifications, estimates, reports or other documents or Instruments relating to or intended to be used for any part or parts of the architectural or engineering project. Additionally these drawings and seal(s) shall in no way convey or imply any time of warranty or certification relating to the performance of products and materials beyond those provided by their respective manufacturer. III I PROJECT NO. 16.0430.01 DRAWN/REVIEWED GFIBB DATE/ISSUE 8.31.2016 SHEET TITLE ELEC PANEL SCHEDULES & RISER DIAGRAM I,I�IIII VIII SHEET NO. E3.0 (0 Ir— co M W W U3 OQ_j°r° _i OO 0ol WW�< J z W WW UW Z J UI~— °6 Z) I— W d�o� U) O 00 (N These drawings/specifications are the property of Kamus + Keller. They are furnished as contract documents only. The seal(s) and signature(s) apply only to the documents to which they affixed, and expressly dispiaim any responsibility for all other plans, specifications, estimates, reports or other documents or Instruments relating to or intended to be used for any part or parts of the architectural or engineering project. Additionally these drawings and seal(s) shall in no way convey or imply any time of warranty or certification relating to the performance of products and materials beyond those provided by their respective manufacturer. III I PROJECT NO. 16.0430.01 DRAWN/REVIEWED GFIBB DATE/ISSUE 8.31.2016 SHEET TITLE ELEC PANEL SCHEDULES & RISER DIAGRAM I,I�IIII VIII SHEET NO. E3.0 J T N O O 1.0 NAMEPLATES 1.0 GROUNDING AND BONDING BLACK BROWN 1.1GENERAL: FURNISH AND MOUNT ON EACH PANEL BOARD/SWITCHBOARD (INCLUDING BRANCH 1_1 GROUND ALL EQUIPMENT PER N.E.C. BLUE SWITCHES), LARGE JUNCTION BOX, SAFETY SWITCH, STARTER, REMOTE CONTROL, PUSHBUTTON NEUTRAL WHITE GREY STATION, AND ALL SIMILAR CONTROLS A NAMEPLATE DESCRIPTIVE OF THE EQUIPMENT OR 1_2 GROUND ALL DRY TYPE TRANSFORMERS AS PER DRAWINGS AND N.E.C. EQUIPMENT CONTROLLED. STOP IN ALL OPENINGS CREATED THROUGH FIRE -RATED WALLS, FLOORS, OR CEILINGS. J SHALL BE THE EQUAL OF 3M PRODUCTS SCOTCH #35. 1_3 ALL CONDUITS SHALL CONTAIN A CODE -SIZED GROUND WIRE SIZE PER N.E.C. IN ADDITION TO 1.2 PROVIDE BLACK AND WHITE NAMEPLATES CONSTRUCTED FROM LAMINATED PHENOLIC WITH A THE CONDUCTORS SHOWN ON THE PLANS. WHERE CIRCUIT CONDUCTORS ARE INCREASED IN SIZE WHITE CENTER CORE. LETTERS SHALL BE ENGRAVED IN THE PHENOLIC TO FORM WHITE rC FOR VOLTAGE DROP, THE GROUND WIRE SIZE SHALL BE INCREASE PROPORTIONATELY. co LETTERS 3/8" HIGH. FASTEN THE NAMEPLATES WITH SCREWS AND ADHESIVE FASTENER. 4.0 MATERIALS AND WORKMANSHIP C 1.4 WHERE AN ISOLATED, INSULATED GROUND IS REQUIRED A SEPARATE GREEN GROUND SHALL BE 2.0 MOUNTING ACCESSORIES 4.1ALL RUN FROM THE PANEL GROUND BUS TO THE ISOLATED GROUND CONNECTION OF THE DEVICE W FOR #10AWG AND SMALLER. THHN SHALL NOT BE USED IN WET OR DAMP LOCATIONS. W SERVED. IN NO CASE SHALL THE SYSTEM GROUND (WIRE AND ASSOCIATED OUTLET BOXES, 2.1 THIS CONTRACTOR SHALL FURNISH AND INSTALL ALL ANGLE IRON, CHANNEL IRON, RODS, CONDUIT AND BUILDING STEEL) BE ALLOWED TO CONTACT THE ISOLATED GROUND (GREEN WIRE 1_3 SUPPORTS, HANGERS, CONCRETE OR PLYWOOD REQUIRED TO INSTALL, MOUNT AND SUPPORT 4.2 AND DEVICE GROUND). 7w ANY ELECTRICAL EQUIPMENT OR DEVICE CALLED FOR ON THE PLANS. SEVERAL KINDS UNLESS SPECIFIED OR INDICATED ON THE DRAWINGS TO THE CONTRARY. 2 2SUPPORTING TERIAL SHALL BE COMPLETE WITH HANGERS, CONNECTORS, BOLTS, CLAMPS, PHALLND DIVISION 16120 WIRE AND CABLE DURING EACH PHASE AND AT THE COMPLETION OF THE CONSTRUCTION, THIS CONTRACTOR SHALL NECESSARY ACCESSOR ES TO MAKE A COMPLETE INSTALLATION. SUPPORTING MATERIA BIDDING. REMOVE ALL DEBRIS AND EXCESS MATERIALS CAUSED BY HIS WORK. HE SHALL LEAVE THE AREA BE GALVANIZED, PAINTED OR OTHERWISE SUITABLY FINISHED. PRODUCTS BY BINKLEY, STEEL CITY PROVIDE MINIMUM #12 CONDUCTORS, UNLESS OTHERWISE INDICATED. OF OPERATION BROOM CLEAN. OR RACO WILL BE ACCEPTABLE. 1.0 WIRE AND CABLE 2_3 ALL SURFACE -MOUNTED EQUIPMENT ON BLOCK WALLS SHALL BE MOUNTED ON 3/4" PLYWOOD 1-1 COLOR CODE CONDUCTORS (EXCEPT CONTROL AND INSTRUMENTATION CONDUCTORS) AS BACKBOARD. ALL FLOOR -MOUNTED EQUIPMENT SHALL BE INSTALLED ON A 4" HIGH CONCRETE PAD. CLASS 2. FOLLOWS. 3.0 EXECUTION 3_1 THE ELECTRICAL WORK FOR CONSTRUCTION PURPOSES SHALL CONFORM TO ALL FEDERAL (OSHA), STATE, ALL SPECIFIC SAFETY REQUIREMENTS AND THE CURRENT EDITION OF THE NEC. 3_2 CHECK THE HVAC AND PLUMBING SPECIFICATIONS FOR ELECTRICAL REQUIREMENTS AND INCLUDE THE SAME IN THE CONTRACT COST. 3.3 EQUIPMENT CONNECTIONS, STARTERS, DISCONNECT SWITCHES, CONTROL TRANSFORMERS AND PUSH-BUTTON STATIONS FOR THE EQUIPMENT FURNISHED BY THE OWNER OR UNDER A SEPARATE CONTRACT SHALL BE INSTALLED AND CONNECTED UNDER THIS DIVISION, AS INDICATED ON THE CONTRACT DRAWINGS. 3_4 120/208 277/480 PHASE A BLACK BROWN PHASE B RED ORANGE PHASE C BLUE YELLOW NEUTRAL WHITE GREY GROUND GREEN GREEN 3_4 ALL CUTTING, PATCHING, EXCAVATING, BACK FILLING AND CONCRETE WORK RELATED TO THIS 1.1a #12 AND #10 CONDUCTORS SHALL HAVE CONTINUOUS INSULATION COLOR, AS LISTED ABOVE. CONTRACT WILL BE THE RESPONSIBILITY OF THE ELECTRICAL CONTRACTOR. THIS CONTRACTOR r M SHALL ASSUME THE RESPONSIBILITY OF PROVIDING THE SLEEVES, CHASES AND OPENINGS 1,1b CONDUCTORS LARGER THAN ABOVE, WHICH DO NOT HAVE CONTINUOUS INSULATION COLOR NECESSARY FOR THE ELECTRICAL INSTALLATION AND FOR THEIR REPAIR IN AN ACCEPTABLE SHALL BE COLOR CODED BY APPLICATION OF AT LEAST TWO LAPS OF COLORED TAPE ON MANNER, AS DETERMINED BY THE ARCHITECT. ALL HOLES SHALL BE CORE -DRILLED. PROVIDE FIRE EACH CONDUCTOR AT ALL POINTS OF ACCESS INCLUDING JUNCTION BOXES. COLOR TAPE STOP IN ALL OPENINGS CREATED THROUGH FIRE -RATED WALLS, FLOORS, OR CEILINGS. J SHALL BE THE EQUAL OF 3M PRODUCTS SCOTCH #35. 3_5 THIS CONTRACTOR SHALL BE RESPONSIBLE FOR PROVIDING ALL REQUIRED ACCESS PANELS 0<c�T- 1.1c CONDUCTORS SHALL BE SOFT ANNEALED COPPER INSULATED FOR 600 VOLTS UNLESS NECESSARY FOR HIS WORK, COORDINATE WITH ARCHITECT PRIOR TO INSTALLATION. SPECIFICALLY INDICATED OTHERWISE. ALUMINUM CONDUCTORS ARE NOT ALLOWED ON THIS rC < co PROJECT. 4.0 MATERIALS AND WORKMANSHIP C ry 1_2 INSULATION TYPE SHALL BE TYPE THW FOR WIRE SIZES #8 AWG AND LARGER AND THHN OR THWN 4.1ALL WORK SHALL BE INSTALLED IN A PRACTICAL WORKMANLIKE MANNER BY MECHANICS SKILLED IN W FOR #10AWG AND SMALLER. THHN SHALL NOT BE USED IN WET OR DAMP LOCATIONS. W THE SEVERAL TRADES NECESSARY <UJ 1_3 PROVIDE WIRE AND RACEWAY SYSTEM AS DESCRIBED HEREIN AND AS INDICATED ON THE 4.2 ALL MATERIALS SHALL BE NEW AND FREE FROM DEFECTS AND SHALL BE THE BEST OF THEIR 7w DRAWINGS. METAL -CLAD (MC.) ARMORED CABLE (AC) AND NON-METALLIC SHEATHED CABLE (NMC) SEVERAL KINDS UNLESS SPECIFIED OR INDICATED ON THE DRAWINGS TO THE CONTRARY. =U~ SHALL NOT BE PERMITTED UNLESS NOTED SPECIFICALLY OTHERWISE AND APPROVED PRIOR TO 4.3 DURING EACH PHASE AND AT THE COMPLETION OF THE CONSTRUCTION, THIS CONTRACTOR SHALL 06W BIDDING. REMOVE ALL DEBRIS AND EXCESS MATERIALS CAUSED BY HIS WORK. HE SHALL LEAVE THE AREA 1_4 PROVIDE MINIMUM #12 CONDUCTORS, UNLESS OTHERWISE INDICATED. OF OPERATION BROOM CLEAN. 4.4 ALL ELECTRICAL EQUIPMENT SHALL BEAR THE UNDERWRITERS LABORATORIES LABEL OR ETL 1.4a CONTROL CONDUCTORS SHALL BE #14 MINIMUM FOR N.E.C. CLASS 1 AND #16 FOR N.E.C. CLASS 2. LABEL. 4_5 THIS CONTRACTOR SHALL GUARANTEE HIS WORKMANSHIP AND MATERIAL (LAMPS EXCEPTED) FOR 1_5 CONDUCTORS #8 AWG AND LARGER SHALL BE STRANDED. A PERIOD OF ONE YEAR FROM THE DATE OF BUILDING OPENING AND LEAVE HIS WORK IN PERFECT 1.6 CONDUCTORS #10 AWG AND SMALLER SHALL BE SOLD ORDER AT THE COMPLETION. SHOULD DEFECTS DEVELOP WITHIN THE GUARANTEE PERIOD, THE - CONTRACTOR SHALL, UPON NOTICE OF THE SAME, REMEDY THE DEFECTS AND HAVE ALL 1_7 INSTALL ALL WIRING IN CONDUIT. DAMAGES TO OTHER WORK OR FURNISHINGS CAUSED BY THE REPAIRS CORRECTED AT HIS EXPENSE TO THE CONDITION BEFORE SUCH DAMAGE. 1.8 CONNECT #10 AND SMALLER WIRES WITH CONSTANT PRESSURE EXPANDABLE SPRING TYPE CONNECTORS, "SCOTCHLOK" BY 3M OR B -CAP BY BUCHANAN. 5.0 SCOPE OF WORK 1_9 CONNECT #8 AND LARGER WIRES WITH COMPRESSION CONNECTORS OR SPLICES AS 5.1 THE ELECTRICAL CONTRACTOR SHALL PROVIDE ALL LABOR, MATERIAL, STORAGE, UNPACKING AND MANUFACTURED BY BURNDY OR T&B. PLACEMENT; TO INCLUDE BUT NOT BE LIMITED TO, THE FOLLOWING ITEM: 1.10 INSULATE SPLICING CONNECTORS TO AT LEAST 200% OF THE WIRE INSULATION. USE 5.1a EMERGENCY LIGHTING AND POWER - PRE -STRETCHED TUBING CONNECTOR INSULATORS. 3M PST FOR #2 AND LARGER CONDUCTORS. 5.1b COMPLETE POWER AND LIGHTING DISTRIBUTION SYSTEM INCLUDING ALL TRANSFORMERS 1.11 PULL CONDUCTORS USING RECOGNIZED METHODS AND EQUIPMENT LEAVING AS LEAST 6" WIRE AT AND FEEDERS ALL JUNCTION BOXES FOR CONNECTIONS. 5.1c COMPLETE BRANCH CIRCUIT WIRING SYSTEM. 1.1 la CLEAN OUT EACH CONDUIT SYSTEM BEFORE PULLING WIRE. 5.1d COMPLETE POWER WIRING FOR ALL AIR CONDITIONING EQUIPMENT, PLUMBING 1,12 FORM AND TIE ALL WIRING IN PANEL BOARDS. SYSTEM, HEATING EQUIPMENT, VENTILATING AND EXHAUST EQUIPMENT. 1.13 THERE SHALL BE NO WIRE NUT JOINTS OR SPLICES MADE INSIDE SWITCHBOARDS/ PANEL BOARDS. 5.1e COMPLETE LIGHTING FIXTURE INSTALLATION, INCLUDING ALL INCANDESCENT, FLUORESCENT AND HID LAMPS. 1.14 BRANCH CIRCUIT WIRE SIZES (AND CONDUITS) SHALL BE INCREASED FROM THOSE INDICATED ON THE PLANS TO PREVENT EXCESSIVE VOLTAGE DROP. BRANCH CIRCUITS SHALL BE INSTALLED WITH 5.1f COMPLETE COMMUNICATIONS CONDUIT AND WIRING SYSTEM INCLUDING BOXES, PLATES, WIRES OF SUFFICIENT SIZE SO THAT VOLTAGE DROP BETWEEN THE PANEL AND THE LOADS DOES JACKS, ETC., AS SPECIFIED, SHOWN ON THE DRAWINGS AND REQUIRED BY THE TENANT. NOT EXCEED LIMIT OF 35. 5_1g TEMPORARY ELECTRICAL POWER AND LIGHTING AS REQUIRED FOR CONSTRUCTION. 1.15 WIRE SIZES SHALL BE BASED ON THE 60°C. AMPACITIES FOR WIRE SIZES NO. 14-1 A.W.G., AND 75°C. AMPACITIES FOR WIRE SIZES #1/0 A.W.G. AND LARGER. 5.1 h TESTING OF ALL CABLES AND CIRCUIT WIRING AFTER INSTALLATION. 1.16 CIRCUITS MAY BE MULTI-PLEXED IN CONDUIT PROVIDED WIRE IS PROPERLY DERATED AND 5_1 ii EXIT LIGHT SYSTEM. CONDUIT SIZED PER CODE. UNDER NO CIRCUMSTANCES SHALL MORE THAN (9) CURRENT CARRYING CONDUCTORS BE RUN 1N A SINGLE CONDUIT. 5.11 WIRING DEVICES AND FLOOR BOXES. 1.17 PROVIDE WIRE AND RACEWAY SYSTEMS AS DESCRIBED HEREIN AND INDICATED ON DRAWINGS. 5.1k LIGHTING CONTROLS. METAL -CLAD (MC), ARMORED CABLE (AC), AND NON-METALLIC SHEATED CABLE (NMC) SHALL NOT BE PERMITTED, UNLESS NOTED SPECIFICALLY OTHERWISE AND APPROVED PRIOR TO 5.11GROUNDING OF THE ELECTRICAL SYSTEM. - BIDDING. 5.1m FIRE SUPERVISORY ALARM SYSTEM. 5.1 n TELEPHONE AND ELECTRIC SERVICES 5.10 SOUND SYSTEM COMPONENTS, CONDUIT SYSTEM & WIRING DIVISION 16130 - RACEWAYS AND BOXES 1.0 RACEWAYS 1.1 ALL WIRE SHALL BE RUN IN ACCORDANCE WITH CODE IN CORROSION RESISTANT, RIGID, THREADED, METAL CONDUIT OR ELECTRICAL METALLIC TUBING (E.M.T.) UNLESS OTHERWISE SPECIFICALLY STATED HEREIN. 1.2 CONDUIT SIZE SHALL BE 3/4" MINIMUM. 1.3 CONDUIT SHALL BE SECURELY FASTENED IN PLACE. 1.4 ALL CONDUIT SHALL BE CONCEALED IN WALLS, FLOOR AND CEILINGS WHEREVER POSSIBLE. EXPOSED CONDUIT IN FINISHED AREAS WILL NOT BE PERMITTED. EXPOSED CONDUIT WILL BE PERMITTED IN UNFINISHED AREAS WITH THE SPECIFIC APPROVAL OF THE ARCHITECT. 1.5USE FLEXIBLE CONDUIT FOR THE CONNECTION TO RECESSED OR SEMI -RECESSED LIGHTING FIXTURES (6' LENGTH MAXIMUM). USE LIQUID TIGHT METAL CONDUIT FOR ALL CONNECTIONS TO MOTORS AND OTHER EQUIPMENT SUBJECT TO VIBRATION AND IN AREAS SUBJECT TO MOISTURE. 1_6 USE WATERTIGHT JOINTS WITH BURIED AND CONCRETE ENCASED CONDUIT. ALL BURIED CONDUIT OUTSIDE OF BUILDINGS SHALL HAVE A MINIMUM OF 24" OF COVER. METAL CONDUITS BURIED IN EARTH SHALL BE PAINTED (TWO COATS) WITH HEAVY ASPHALTUM PAINT. 1.7 SUPPORT RUNS OF CONDUIT AS DETAILED IN THE APPROPRIATE TABLE OF THE NATIONAL ELECTRICAL CODE (NEC). 1_8 INSTALL EXPOSED RUNS OF CONDUIT AND CONDUIT ABOVE LAY -IN CEILING PARALLEL OR PERPENDICULAR TO THE WALLS, STRUCTURAL MEMBERS OF INTERSECTIONS OF VERTICAL PLANES AND CEILINGS. PROVIDE RIGHT ANGLE TURNS USING FITnINGS OR SYMMETRICAL BENDS. SUPPORT CONDUITS WITHIN 1" OF ALL CHANGES IN DIRECTION. 1_9 IF A CONDUIT IS SUSPENDED, IT SHALL BE SUPPORTED ON TRAPEZE HANGERS WHICH USE "ALL -THREAD" RODS FROM THE STRUCTURAL STEEL. THE USE OF CEILING SUPPORT WIRE OR SIMILAR MATERIAL WILL NOT BE ACCEPTED. 1.10 INSTALL EMPTY CONDUIT FOR FUTURE USE AS INDICATED ON THE DRAWINGS. CONDUIT SHALL BE COMPLETE WITH JETLINE OR PULL ROPE, JUNCTION/OUTLET BOXES, TILE RINGS AND APPROPRIATE COVER PLATES. 1.11 PROVIDE PITCH POCKETS WHERE CONDUITS PENETRATE THE ROOF. 1.12 THREAD LUBRICATION/SEALANT IS REQUIRED ON OUTDOOR AND UNDERGROUND THREADED METAL JOINTS. 1.13 INSTALL FIRE SEAL FITTINGS WHERE CONDUITS PENETRATE CONCRETE FLOOR SLABS OR MASONRY WALLS REQUIRED TO BE FIRE RATED. 1.14 HORIZONTAL PORTION OF CONDUIT EXPOSED ON THE ROOF AND FEEDING EQUIPMENT SHALL NOT BE MORE THAN 5'-0" UNLESS THE WRITTEN APPROVAL FROM ARCHITECT OR ENGINEER IS OBTAINED. 2.0 PULL AND JUNCTION BOXES 2_1 INSTALL PULL AND JUNCTION BOXES WHERE SHOWN ON THE DRAWINGS, AND WHERE REQUIRED FOR CHANGES IN DIRECTION, AT JUNCTION POINTS, AND TO FACILITATE WIRE PULLING. FURNISH BOX SIZES IN ACCORDANCE WITH NEC UNLESS LARGERBOXES ARE INDICATED. 2_2 PROVIDE STEEL BOXES AND REMOVABLE COVERS OF CODE GAGE, HOT ROLLED SHEET STEEL, HOT DIPPED GALVANIZED INSIDE AND OUTSIDE, FOR ABOVE GROUND WORK. FURNISH WEATHERPROOF BOXES WHEN INSTALLED ABOVE GROUND OUTSIDE. 2_3 PROVIDE CAST IRON BOXES, HOT DIPPED GALVANIZED NSIDE AND OUTSIDE WHERE SHOWN ON THE DRAWINGS. FURNISH REMOVABLE COVERS WITH GASKETS AND STAINLESS STEEL, BRASS OR BRONZE SCREWS. 2.4 PROVIDE CONCRETE BOXES FOR UNDERGROUND WORK UNLESS OTHERWISE INDICATED ON THE DRAWINGS. FURNISH STEEL FRAMES AND COVERS WITH THE COVER ATTACHED TO THE FRAME WITH HEXAGON HEAD, BRASS OR BRONZE CAP SCREWS, 3/8" IN DIAMETER. PROVIDE A RUBBER GASKET FOR SEALING BETWEEN THE COVER AND THE FRAME. PAINT THE COVER WITH TWO COATS OF HEAVY ASPHALTUM. 3.0 OUTLET BOXES 3_1 USE SHEET STEEL BOXES, ZINC COATED OR CADMIUM PLATED, FOR CONCEALED INTERIOR WORK. 3_2 USE CAST BOXES, ZINC -CADMIUM FINISH MALLEABLE IRON, FOR EXPOSED INTERIOR WORK, AND FOR EXPOSED OR CONCEALED WORK IN WET, DAMP OR EXTERIOR LOCATIONS. CAST BOXES SHALL BE SERIES FD BY CROUSE HINDS OR APPLETON. 3_3 WALL BOX SIZES (MINIMUM) SHALL BE 4" SQUARE X 2-1/2"DEEP WHERE WALL CONSTRUCTION PERMITS. WHERE WALL CONSTRUCTION DICTATES, THE WIDTH MAY BE REDUCED TO 2-1/8" OR 1-1/2" UNDER SPECIAL CONDITIONS. 3.4 FIXTURE OUTLETS IN CEILINGS (MINIMUM) SHALL BE 4" OC AGONAL X 1-1/2" DEEP (4-11/16" OCTAGONAL X 2-1/2" DEEP WHERE REQUIRED TO ACCOMNDDATE LARGER CONDUIT OR LARGER NUMBER OF WIRES). 3.5 GANG BOXES SHALL BE ONE PIECE (MINIMUM), 2-1/8" DEEP. 3.6 PROVIDE FLUSH FLOOR BOX SERIES 880 BY WIRE MOLD WTH DUPLEX RECEPTACLE FOR WOOD PLATFORM AT DISPLAY SHOW WINDOWS, BOX WITH COVER PLATE FLANGE: CAT. #880W1-817TCAL AND BRUSHED ALUMINUM COVER PLATE: CAT. #828R-TCAL WITH FLIP LID TO PROTECT RECEPTACLE WHEN NOT IN USE. BOTH FLANGE AND COVER PLATE SHALL HAVE BRUSHED ALUMINUM FINISH. UL SCRUB LISTED. 3_7 FLUSH MOUNT BOXES IN ALL FINISHED WALLS, INSTALL THE PLASTER RINGS IN DRY WALLED PLASTERED WALLS AND RAISED COVERS AS REQUIRED IN WALLS WITH OTHER FINISHES SO THAT THE COVER PLATES FIT TIGHTLY AGAINST BOXES OR RINGS. 3/16" MAXIMUM GAPS ARE ALLOWED FOR NONCOMBUSTIBLE WALLS. 3_8 SUPPORT ALL BOXES TO MAINTAIN PROPER ALIGNMENT AND RIGIDITY. DIVISION 16140 - WIRING DEVICES 1.0 WIRING DEVICES 1_1 WIRING DEVICE COLOR SHALL BE WHITE, UNLESS OTHERWISE NOTED. 1.2 PROVIDE TOTALLY ENCLOSED, 20 AMPERE, 120/277 VOLT, QUIET A/C GENERAL USE SNAP SWITCHES. 1.3 SWITCHES SHALL BE SPECIFICATION GRADE AS MANUFACTURED BY HUBBELL, P&S, OR LEMON. 1.4 PROVIDE NEMA CONFIGURATION 5-20R DUPLEX 125 VOLT GROUNDING TYPE RECEPTACLES RATED FOR 20 AMPERES UNLESS OTHERWISE INDICATED ON THE DRAWINGS. 1.5 RECEPTACLES SHALL BE SPECIFICATION GRADE AS MANUFACTURED BY HUBBELL, P&S OR LEVITON. 1_6 RECEPTACLES REQUIRING AMPERAGES, VOLTAGES OR CONFIGURATIONS DIFFERENT FROM THE DUPLEX CONVENIENCE RECEPTACLES ABOVE SHALL BE AS INDICATED ON THE DRAWINGS. 1_7 PROVIDE OTHER RECEPTACLES OF A QUALITY, MATERIAL AND WORKMANSHIP EQUAL TO THAT SPECIFIED FOR DUPLEX CONVENIENCE RECEPTACLES. 1.8 PROVIDE COVER OR DEVICE PLATES FOR OUTLET BOXES AS FOLLOWS UNLESS OTHERWISE NOTED: 1.8a FINISHED AREAS: THERMOPLASTIC -COLOR TO MATCH DEVICE. 1.8b UNFINISHED AREAS: ZINC COATED SHEET METAL, ALUMINUM, OR CAST METAL AS APPROPRIATE FOR THE TYPE OF BOX. 1.8c EXTERIOR AREAS: COPPER FREE ALUMINUM WITH GRAY, POWDER EPDXY FINISH, GASKET, WEATHERPROOF, CROUSE -HINDS "WLRD" FOR DUPLEX RECEPTACLES AND WLRS FOR SINGLE RECEPTACLES OR EQUAL. 1.8d TELEPHONE COMMUNICATIONS, AND SIGNAL OUTLET PLATES, SHALL MATCH THOSE USED FOR RECEPTACLES AND SWITCHES. ALL OUTLET AND/OR JUNCTION BOXES SHALL BE COMPLETE WITH A COVER PLATE BY THIS CONTRACTOR. 1.8e WHERE DEVICES ARE GANGED, THEY SHALL BE INSTALLED UNDER A COMMON COVER PLATE. 1_9 LOCATE THE SWITCHES APPROXIMATELY 4'-0" ABOVE THE FINISHED FLOOR ELEVATION OR NEAREST BLOCK COURSE (WITHIN A.D.A. REQUIREMENTS), UNLESS OTHERWISE INDICATED. THE LONG DIMENSION OF THE SWITCHES SHALL BE VERTICAL. 1.10 LOCATE RECEPTACLES APPROXIMATELY 1'-6" ABOVE THE FINISHED FLOOR ELEVATION OR NEAREST BLOCK COURSE (WITHIN A.D.A. REQUIREMENTS), UNLESS NOTED OTHERWISE THE LONG DIMENSION OF RECEPTACLES SHALL BE VERTICAL. DIVISION 16410 - SAFETY SWITCHES 1.0 SAFETY SWITCHES 1_1 SAFETY SWITCHES SHALL BE THE ENCLOSED HEAVY-DUTY TYPE (TYPE HD) WITH QUICK -MAKE, QUICK -BREAK MECHANISM AND EXTERNAL PAD LOCKABLE OPERATING HANDLE. 1_2 SAFETY SWITCHES SHALL BE RATED FOR 240 OR 600 VOLTS AS APPLICABLE. THEY SHALL BE HORSEPOWER RATED WHEN USED IN MOTOR CIRCUITS. 1_3 SAFETY SWITCHES SHALL BE FUSIBLE OR NON -FUSIBLE 2, 3 OR 4 POLE AS INDICATED ON THE DRAWINGS. 1_4 SAFETY SWITCHES SHALL BE SINGLE THROW UNLESS OTHERWISE INDICATED ON THE DRAWINGS. 1_5 ENCLOSURES SHALL BE NEMA 1 INDOORS AND NEMA 3R OUTDOORS UNLESS OTHERWISE INDICATED ON THE DRAWINGS. 1_6 MANUFACTURER SHALL BE SQUARE D, SEIMENS OR CULTER-HAMMER. 1_7 MOUNT THE SAFETY SWITCHES SECURELY BETWEEN TX 6' LEVELS ABOVE THE FLOOR UNLESS OTHERWISE INDICATED ON THE DRAWINGS. 1_8 MOUNT THE SAFETY SWITCHES SECURELY BETWEEN TX T LEVELS ABOVE THE FLOOR UNLESS OTHERWISE INDICATED ON THE DRAWINGS. 1_9 SWITCHES ON BLOCK WALLS SHALL BE MOUNTED ON A 3/4" PLYWOOD BACKBOARD, WHERE LOCATED INDOORS. DIVISION 16420 -MOTOR STARTERS 1.0 MOTOR STARTERS 1_1 PROVIDE MOTOR STARTERS (MAGNETIC OR FUSED COMBINATION) AND CONTROL EQUIPMENT WHERE SHOWN. STARTERS SHALL BE PROVIDED WITH 120 VOLT COILS, 3 OVERLOADS, CONTROL TRANSFORMER WITH FUSED 120 VOLT SECONDARY CONTROL CIRCUIT, (2) N.O. AND (2) N.C. AUXILIARY CONTACTS, HAND -OFF -AUTO SELECTOR SWITCH AND RUNNING PILOT LIGHT, UNLESS OTHERWISE NOTED. WIRE THRU CONTROL DEVICES FURNISHED BY OTHER TRADES. SINCE MOTOR DRIVEN EQUIPMENT IS FURNISHED BY OTHER TRADES, THE CONTROL INDICATED ON THE DRAWINGS SHALL BE CONSIDERED AS FOR BIDDING PURPOSES ONLY. WIRE TO CONFORM TO THE ACTUAL EQUIPMENT SUPPLIED AND INSTALLED BY THE OTHER TRADES. ALL FUSES SHALL BE DUAL ELEMENT TYPE. PROVIDE "BLOWN FUSE" INDICATOR LAMPS IN COVER. 1_2 STARTERS SHALL BE SQUARE D, SEIMENS OR CUTLER -HAMMER. 1_3 THE EXACT NUMBER OF NORMALLY OPEN AND NORMALLY CLOSED AUXILIARY CONTACTS IN EACH STARTER SHALL BE DETERMINED BY THE TEMPERATURE CONTROL AND/OR FIRE ALARM CONTRACTOR. i 1.0 LIGHTING CONTROL SYSTEM 1_1 GENERAL INTRODUCTION: THE WORK COVERED IN THIS SECTION IS SUBJECT TO ALL THE REQUIREMENTS IN THE GENERAL CONDITIONS OF THE SPECIFICATIONS. THE CONTRACTOR SHALL COORDINATE ALL OF THE WORK IN THIS SECTION WITH ALL OF THE TRADES COVERED IN OTHER SECTIONS OF THE SPECIFICATION TO PROVIDE A COMPLETE AND OPERABLE SYSTEM. 1.2 DESCRIPTION OF THE WORK: 1.2a THE EXTENT OF THE LIGHTING CONTROL SYSTEM WORK IS INDICATED BY THE DRAWINGS AND BY THE REQUIREMENTS OF THIS SECTION. IT IS DEFINED TO INCLUDE, BUT NOT BY WAY OF LIMITATION: 1.2a1 PANELBOARDS CONTAINING INTEGRAL CONTACTORS. 1.2a2 CONTROL ELECTRONICS FOR CONTACTORS AND TIMECLOCKS AND MONITORING THE STATUS OF THE SYSTEM. 1.20 ASSOCIATED LOW AND LINE VOLTAGE OVERRIDE SWITCHES AND LIGHT SENSORS. 1.2a4 TIMECLOCKS, CONTACTORS. 1.2a5 ANY WORK STATIONS, SOFTWARE AND COMMUNICATIONS HARDWARE. 1.2b SYSTEM INSTALLATION INCLUDES THE FOLLOWING: 1.2b1 WIRING OF BRANCH CIRCUIT CONDUCTORS AND CONTACTORS 1.2b2 INSTALLATION OF EXTERNAL CONTROL DEVICES AND WIRING TO THE CONTROLLER. 1.2b3 INSTALLATION OF COMMUNICATIONS CONDUCTORS AND ASSOCIATED HARDWARE. 1_3 WARRANTY: MANUFACTURER SHALL WARRANT SPECIFIED EQUIPMENT TO BE FREE FROM DEFECTS IN MATERIALS AND WORKMANSHIP FOR AT LEAST ONE YEAR FROM THE DATE OF INSTALLATION OR EIGHTEEN MONTHS FROM DATE OF PURCHASE. 2.0 PANELBOARDS 2_1 ACCEPTABLE MANUFACTURERS: SQUARED CUTLER HAMMER SEIMENS G.E. FOR PRICING AND ORDERING INFORMATION PROVIDE EQUIPMENT AS SPECIFIED HEREIN NO SUBSTITUTIONS PERMITTED. CONTRACTOR SHALL CONTACT NO LATER THAN 5 DAYS AFTER JOB IS AWARDED TO ENSURE LEAD TIMES DO NOT AFFECT PROJECT SCHEDULE. PANELBOARDS SHALL BE ENCLOSED DEAD FRONT SAFETY TYPE WITH FEATURES AND RATINGS AS SCHEDULED ON THE DRAWINGS. 2_2 PANELS KNOWN AS "LOAD CENTERS" ARE UNACCEPTABLE. 2_3 MOLDED CASE CIRCUIT BREAKERS SHALL BE AS SCHEDULED ON THE DRAWINGS AND SPECIFIED IN THIS DIVISION. 2.4 ALL BUS BARS SHALL BE RECTANGULAR, SOLID COPPER. 2_5 SPACE, WHERE SHOWN IN PANEL SCHEDULES, DESIGNATES SPACE FOR FUTURE PROTECTIVE DEVICES AND SHALL INCLUDE BUS AND SUPPORT. 2.6 INSTALL CABINETS SO THAT CENTER OF THE TOP BREAKER DOES NOT EXCEED 6'-6" ABOVE THE FINISHED FLOOR. 2_7 ENTRIES ON DIRECTORY CARDS SHALL BE TYPED, COMPLETE AND ACCURATE. 2_8 ALL BOLTED CONNECTIONS SHALL BE TORQUED IN ACCORDANCE WITH MANUFACTURER'S STANDARDS. 2_9 ELECTRICAL CONTRACTOR SHALL ARRANGE CIRCUITS AS NEAR AS POSSIBLE TO CIRCUIT NUMBERS ON THE DRAWINGS. AT COMPLETION OF JOB, ELECTRICAL CONTRACTOR SHALL TAKE CURRENT READING CHECKS OF RESPECTIVE PHASES. A MINIMUM OF CIRCUIT CONNECTIONS SHALL BE REARRANGED TO BALANCE AS CLOSELY AS POSSIBLE, THE LOAD IN THE PANEL. 2.10 ALL BREAKERS SHALL BE BOLT -ON TYPE. 2.11 PROVIDE (3) SPARE 1" CONDUITS INTO ACCESSIBLE CEILING SPACE WHERE PANELS ARE FLUSH -MOUNTED. 3.0 DISTRIBUTION PANELS 3.1 ACCEPTABLE MANUFACTURERS: SQUARE D. CUTLER HAMMER, SEIMENS. G.E.. FOR PRICING AND ORDERING INFORMATION, PROVIDE EQUIPMENT AS SPECIFIED HEREIN, NO SUBSTITUTIONS PERMITTED. CONTRACTOR SHALL CONTACT NO LATER THAN 5 DAYS AFTER JOB IS AWARDED TO ENSURE LEAD TIMES DO NOT AFFECT PROJECT SCHEDULE. DISTRIBUTION PANELS SHALL BE DEAD FRONT TYPE WITH FEATURES AND RATING AS SCHEDULED ON THE DRAWINGS. 3_2 MOLDED CASE CIRCUIT BREAKERS SHALL BE AS SCHEDULED, OF SIZE AND NUMBER INDICATED ON THE DRAWINGS. ALL BREAKERS SHALL BE BOLT -ON TYPE. 3_3 ALL LUGS SHALL BE UL APPROVED CU/AL TYPE. 3_4 PANELS SHALL BE MANUFACTURED AS A COMPLETE UNIT AND NOT AN ASSEMBLY OF PARTS SECURED FROM A SUPPLY HOUSE. 3_5 ALL PANELS SHALL BE CAPABLE OF ACCEPTING CIRCUIT BREAKERS SIZED UP TO AND INCLUDING 400 AMPS. 3_6 VERTICAL BUSSING SHALL BE EXTENDED THE FULL LENGTH OF THE PANEL. 3_7 ALL BUS BARS SHALL BE RECTANGULAR SOLID COPPER. 3_8 DISTRIBUTION PANELS SHALL BE SQUARE D. 3_9 INSTALL PANELS SUCH THAT HANDLE FOR THE TOP BREAKER DOES NOT EXCEED 6'-6" ABOVE FINISHED FLOOR. 3.10 PROVIDE PHENOLIC LABELS FOR EACH PANEL. 3.11 ALL BOLTED CONNECTIONS SHALL BE TORQUED IN ACCORDANCE WITH MANUFACTURER'S STANDARDS. 3.12 SURFACE -MOUNTED PANELS SHALL BE MOUNTED ON A 3/4" PLYWOOD BACKBOARD. FLOOR -MOUNTED PANELS SHALL BE MOUNTED ON A 4" HIGH CONCRETE PAD. DIVISION 16461 - DRY TYPE TRANSFORMERS 1.0 TRANSFORMERS 1_1 TRANSFORMERS SHALL BE CONTINUOUSLY RATED ISOLATING TYPE FOR 60 HERTZ SERVICE UNLESS OTHERWISE INDICATED. 1_2 INSULATION SYSTEMS SHALL BE 220 DEGREES C (150 DEGREES RISE). 1_3 ENCLOSURES FOR TRANSFORMERS SHALL BE METALLIC, SUITABLE FOR INDOOR AND OUTDOOR INSTALLATION AS APPLICABLE AND RODENT PROOF. 1_4 MANUFACTURERS SHALL BE SQUARE D. FRACTIONAL KVA TRANSFORMERS SHALL BE MANUFACTURED BY EDWARDS OR THE SPECIAL EQUIPMENT MANUFACTURER IN WHICH THE TRANSFORMERS ARE USED. 1_5 FOUR APPROVED VIBRATION DAMPENERS PER TRANSFORMER SHALL BE EMPLOYED AS NECESSARY TO AVOID TRANSMITTING ANY VIBRATION TO THE BUILDING STRUCTURE. SIZES OF THE MOUNTINGS SHALL BE SELECTED ON THE BASIS OF THE WEIGHT OF THE TRANSFORMER, USING: 1.5a A MINIMUM 1" THICK RUBBER -CORK -RUBBER SANDWICH TYPE FOR FLOOR MOUNTING. 1.5b A SPRING TYPE FOR SUSPENSION MOUNTING. 1.5c TWO(2) SPRING TYPE AT THE TOP (WITH TWO (2) STEEL BRACKETS) AND TWO (2) RUBBER -IN COMPRESSION TYPE AT THE BOTTOM (STAND-OFF) FOR WALL MOUNTING. COMP I i NFPA '70 o NE( SEP 14 2016 ISSUE DATE LO co 'SU) rU)r y N (L XON o ~ixn t` �o EGO m r>> � CO LO m aC (0 V) (9 n - two City of Tukwila BUILDING DIVISION RECEIVED CITY OF TUKWILA SEP 08 2016 PERMIT CENTER P7. S x y P )7 These drawings/spectfications are the property of Kamus + Keller. They are fumished as contract documents only. The seal(s) and signature(s) appy only to the documents to which they affixed, and expressly displaim any responsibility for all other plans, specifications, estimates, reports or other documents or instruments relating to or intended to be used for any part or parts of the architectural or engineering project. Additionally these drawings and seal(s) shall in no way convey or imply any time of warranty or certification retating to the performance of products and materials beyond those provided by their respective manufacturer. III PROJECT NO. 16.0430.01 DRAWN/REVIEWED GFIBB VIII II III III II I DATEIISSUE 8.31.2016 SHEET TITLE ELECTRICAL SPECIFICATIONS II I II III IIII SHEET NO. E1.1 r M W W J 0<c�T- 00 00J 1- rC < co ry C ry UJ Q W I- W S' <UJ 7w =U~ 06W 1-oZ)v <w0 C) 00 N City of Tukwila BUILDING DIVISION RECEIVED CITY OF TUKWILA SEP 08 2016 PERMIT CENTER P7. S x y P )7 These drawings/spectfications are the property of Kamus + Keller. They are fumished as contract documents only. The seal(s) and signature(s) appy only to the documents to which they affixed, and expressly displaim any responsibility for all other plans, specifications, estimates, reports or other documents or instruments relating to or intended to be used for any part or parts of the architectural or engineering project. Additionally these drawings and seal(s) shall in no way convey or imply any time of warranty or certification retating to the performance of products and materials beyond those provided by their respective manufacturer. III PROJECT NO. 16.0430.01 DRAWN/REVIEWED GFIBB VIII II III III II I DATEIISSUE 8.31.2016 SHEET TITLE ELECTRICAL SPECIFICATIONS II I II III IIII SHEET NO. E1.1 GENERAL NOTES 1. ELECTRICAL CONTRACTOR SHALL FIELD VERIFY ALL EXISTING CONDITIONS PRIOR TO BASE BID. IN CASE OF ANY DISCREPANCIES WITH EXISTING FIELD CONDITIONS, ELECTRICAL CONTRACTOR SHALL VERIFY THE EXACT DIFFERENCE FOR POSSIBLE REVISIONS TO THIS DOCUMENT. 2. INSTALL RECESSED LUMINAIRES USING ACCESSORIES AND FIRE STOPPING MATERIALS TO MEET REGULATORY REQUIREMENTS FOR FIRE RATING. 3. LIGHT SWITCHES ARE TO BE MOUNTED AT 42" AFF (UNLESS OTHERWISE NOTED). 4. LIGHT FIXTURES ARE TO BE CENTERED ON CEILING TILES (UNLESS OTHERWISE NOTED). 5. CONTACT ARCHITECT TO COORDINATE LIGHT FIXTURE LOCATIONS IF EXISTING CEILING GRID IS TO BE REUSED. 6. PROVIDE MINIMUM 90 MIN BATTERY PACKS IN EMERGENCY FIXTURES, WHERE INDICATED ON THE DRAWINGS. 7. ELECTRICAL CONTRACTOR SHALL COORDINATE WITH GENERAL CONTRACTOR AND TENANT REPRESENTATIVE FOR ORDERING LUMINAIRES FROM TENANTS NATIONAL ACCOUNT WITH "GRAINGER". 8. PROVIDE BLACK ADHESIVE LABEL ADHERED TO ALL SWITCHED RECEPTACLES WITH 1/4" LETTERING INDICATING "SWITCHED FOR LIGHTING". 9. COORDINATE TIMING OF TIMECLOCK WITH STORE MANAGER. 10. ON ALL MULTI -WIRED HOMERUN CIRCUIT BREAKERS (REFER TO PLANS) CONTRACTOR SHALL FIELD INSTALL ON MULTI -USE CIRCUIT BREAKERS AN APPROVED HANDLE TIE PER NEC. 11. ALL EQUIPMENT SHALL BE LISTED BY A NATIONALLY RECOGNIZED TESTING LABORATORY. 12. IT IS ACCEPTABLE TO USE MIC CABLE FOR BRANCH CIRCUITS OR HOMERUNS PROVIDED IT COMPLIES WITH AUTHORITY HAVING JURISDICTION, LOCAL RECOGNIZED CODE AND LANDLORD. VERIFY PRIOR TO BID. 13. ALL LOW VOLTAGE WIRING TO BE IN CONDUIT UNLESS OTHERWISE APPROVED BY AUTHORITY HAVING JURISDICTION NOTES BY SYMBOL ONUMBER INDICATES CIRCUIT COORDINATION, LETTER INDICATES SWITCH COORDINATION. REFER TO LIGHTING CONTROL DETAIL ON SHEET E1.0. OALL EMERGENCY/EXIT FIXTURES ARE TO BE PROVIDED WITH MINIMUM 90 MIN EMERGENCY BATTERY BACK-UP AND CONNECTED TO UNSWITCHED LEG OF LOCAL CIRCUIT. BY=PASS ENERGY MANAGEMENT SYSTEM WHERE REQUIRED). OALL LIGHTING CIRCUITS INDICATED ON PLANS SHALL BE ROUTED THROUGH THE LIGHTING CONTROL SYSTEM. REFER TO LIGHTING LIGHTING CONTROL DIAGRAM ON SHEET E1.0 FOR ADDITIONAL INFORMATION. 4OSWITCHBANK LOCATION. REFER TO SWITCHBANK DETAIL ON THIS SHEET AND LIGHTING CONTROL DIAGRAM ON SHEET E1.0 FOR ADDITIONAL INFORMATION. OELECTRICAL DISTRIBUTION EQUIPMENT. REFER TO SHEET E3.0 FOR FURTHER COORDINAT OEXISTING BOH LIGHTING AND SWITCHING TO REMAIN. RE -LAMP, REPAIR, RE -BALLAST AS NEEDED TO PROVIDE FULLY FUNCTIONING FIXTURES 7O CONNECT TO EXISTING BOH CIRCUIT AND SWITCHING. V.I.F. SWITCHBANK DETAIL 'a' �b� �'d' >- Y Q Q U Wz N 0 t7 O NOTE: SWITCH CONTROL LOCATION. REFER TO SHEET E1.0 LIGHTING CONTROL DETAIL FOR NUMBER OF POLES REQUIRED. SWITCHES SHALL BE INSTALLED BETWEEN STUDS. MAKE (MORE) ROWS IF NECESSARY. DO NOT CUT STUDS TO ACCOMMODATE A SINGLE ROW OF SWITCHES. ALL CONTROL DEVICES FOR LIGHT, POWER, HEAT, ALARMS, ETC. SHALL BE MOUNTED NO HIGHER THAN 42" FROM THE FLOOR. IMPORTANT: T.G.C. SHALL CONNECT EMERGENCY/NIGHT LIGHTING TO LOCAL CIRCUIT ON UNSWITCHED LEG. SCALE: 1/4"=l' -O" REVIEWED RUH' COMPLIANCE , .J e A,H NFPA70 - NEC SEP 14 2016 City of TuWla BUILDING DIVISION A)1rrff11 A w• • • w• • w•�� SEP 08 2016 PERMIT CENTER ISSUE DATE C- � r-nOD co N r � 0 ~r aO m N C) m Q. � �� 9 mfnc0(LLL These dreviings/specifications are the property of Kamus + Keller. They are fumished as contract documents only. The seal(s) and signature(s) apply only to the documents to which they affixed, and expressly displaim any responsibility for all other plans, specifications, estimates, reports or other documents or instruments relating to or Intended to be used for any part or parts of the architectural or engineering project. Additionally these drawings and seal(s) shaft in no way convey or imply any time of warranty or certification relating to the performance of products and materials beyond those provided by their respective manufacturer. PROJECT NO. 16.0430.01 DRAWN/REVIEWED GFIBB DATE/ISSUE 8.31.2016 SHEET TITLE ELECTRICAL LIGHTING PLAN SHEET NO. E2.0 r M W F_ UJ (! U) _jry 0 Q QD 0) Q wW < w UJ _J Q 06 own <U)0 U) 0 00 N These dreviings/specifications are the property of Kamus + Keller. They are fumished as contract documents only. The seal(s) and signature(s) apply only to the documents to which they affixed, and expressly displaim any responsibility for all other plans, specifications, estimates, reports or other documents or instruments relating to or Intended to be used for any part or parts of the architectural or engineering project. Additionally these drawings and seal(s) shaft in no way convey or imply any time of warranty or certification relating to the performance of products and materials beyond those provided by their respective manufacturer. PROJECT NO. 16.0430.01 DRAWN/REVIEWED GFIBB DATE/ISSUE 8.31.2016 SHEET TITLE ELECTRICAL LIGHTING PLAN SHEET NO. E2.0 GENERAL NOTES 1. ELECTRICAL CONTRACTOR SHALL FIELD VERIFY ALL EXISTING CONDITIONS PRIOR TO BASE BID. IN CASE OF ANY DISCREPANCIES WITH EXISTING FIELD CONDITIONS, ELECTRICAL CONTRACTOR SHALL VERIFY THE EXACT DIFFERENCE FOR POSSIBLE REVISIONS TO THIS DOCUMENT. 2. INSTALL RECESSED LUMINAIRES USING ACCESSORIES AND FIRE STOPPING MATERIALS TO MEET REGULATORY REQUIREMENTS FOR FIRE RATING. 3. LIGHT SWITCHES ARE TO BE MOUNTED AT 42" AFF (UNLESS OTHERWISE NOTED). 4. LIGHT FIXTURES ARE TO BE CENTERED ON CEILING TILES (UNLESS OTHERWISE NOTED). 5. CONTACT ARCHITECT TO COORDINATE LIGHT FIXTURE LOCATIONS IF EXISTING CEILING GRID IS TO BE REUSED. 6. PROVIDE MINIMUM 90 MIN BATTERY PACKS IN EMERGENCY FIXTURES, WHERE INDICATED ON THE DRAWINGS. 7. ELECTRICAL CONTRACTOR SHALL COORDINATE WITH GENERAL CONTRACTOR AND TENANT REPRESENTATIVE FOR ORDERING LUMINAIRES FROM TENANTS NATIONAL ACCOUNT WITH "GRAINGER". 8. PROVIDE BLACK ADHESIVE LABEL ADHERED TO ALL SWITCHED RECEPTACLES WITH 1/4" LETTERING INDICATING "SWITCHED FOR LIGHTING". 9. COORDINATE TIMING OF TIMECLOCK WITH STORE MANAGER. 10. ON ALL MULTI -WIRED HOMERUN CIRCUIT BREAKERS (REFER TO PLANS) CONTRACTOR SHALL FIELD INSTALL ON MULTI -USE CIRCUIT BREAKERS AN APPROVED HANDLE TIE PER NEC. 11. ALL EQUIPMENT SHALL BE LISTED BY A NATIONALLY RECOGNIZED TESTING LABORATORY. 12. IT IS ACCEPTABLE TO USE M/C CABLE FOR BRANCH CIRCUITS OR HOMERUNS PROVIDED IT COMPLIES WITH AUTHORITY HAVING JURISDICTION, LOCAL RECOGNIZED CODE AND LANDLORD. VERIFY PRIOR TO BID. 13. ALL LOW VOLTAGE WIRING TO BE IN CONDUIT UNLESS OTHERWISE APPROVED BY AUTHORITY HAVING JURISDICTION NOTES BY SYMBOL ONUMBER INDICATES CIRCUIT COORDINATION, LETTER INDICATES SWITCH COORDINATION. ALL MVU LIGHTING CIRCUITS SHALL BE ROUTED THROUGH ENERGY MANAGEMENT SYSTEM. REFEF TO LIGHTING CONTROL DETAIL ON SHEET E1.0 OELECTRICAL CONTRACTOR TO COORDINATE WITH TELEPHONE/DATA SYSTEM INSTALLER CONDUIT SIZE, REQUIREMENTS AND ROUTING OF TEUDATA CONDUIT IN FIELD PRIOR TO ROUGH -IN. OELECTRICAL CONTRACTOR SHALL COORDINATE WITH ARCHITECTURAL MILLWORK DETAILS FOR FINAL LOCATION OF ALL DEVICES AND TEUDATA CONDUIT AT MILLWORK. INCLUDE ALL J -BOXES, TWO CHANNEL WIREMOLDS AND REQUIRED CONDUITS FOR LINE AND LOW VOLTAGE AS PART OF BASE BID IN ORDER TO OBTAIN A COMPLETE AND OPERATING SYSTEM. OPROVIDE FLUSH FLOOR MOUNTED POWER AND TEUDATA DEVICE AT LOCATION INDICATED ON THE PLANS. PROVIDE FLOOR BOX AND CORRESPONDING ACCESSORIES REQUIRED PER FIELD CONDITIONS (BLACK COVER FOR CARPET FLOORING AND BRASS COVER FOR ALL OTHER FINISHES. O5 CORE FLOOR FOR INSTALLATION OF NEW CONDUITS. PROVIDE CONDUIT AS SHOWN WITH PULL STRING FOR DATA CABLING AND 3/4" CONDUIT WITH POWER WIRING TO FLOOR BOX RECEPTACLES. FIELD VERIFY ROUTING OF CONDUIT PRIOR TO CUTTING FLOOR. PATCH TO MATCH EXISTING. COORDINATE WITH FURNITURE SUPPLIER AND ARCHITECTURAL DIMENSION PLAN PRIOR TO SAW -CUTTING FLOOR. ALL FLOOR MOUNTED DEVICES MUST MEET "SCRUB WATER TEST'. OAT THIS LOCATION, STUB CONDUITS UP THROUGH WALL. ALL TEUDATA CONDUITS SHALL BE STUBBED INTO ACCESSIBLE CEILING SPACE ABOVE. FINAL PLACEMENT OF CONDUITS STUB -UP AT FLOOR SHALL BE COORDINATED WITH TENANT REPRESENTATIVE PRIOR TO INSTALLATION OELECTRICAL CONTRACTOR SHALL PROVIDE DUAL BRANCH CIRCUIT QUAD RECEPTACLES BEHIND MVU. HALF OF QUAD FOR GENERAL POWER AND HALF FOR SWITCHING. REFER TO GENERAL NOTES 8 AND 10 ABOVE. OELECTRICAL DISTRIBUTION EQUIPMENT. REFER TO SHEET E3.0 FOR FURTHER COORDINATION. OELECTRICAL CONTRACTOR TO MAKE FINAL CONNECTION TO TENANT SIGN. IF NOT EXISTING, PROVIDE MEANS OF DISCONNECT AND SEPARATE GROUND PER NEC (CONDUIT GROUND NOT PERMITTED). CIRCUIT SIGN VIA TIMECLOCK, REFER TO LIGHTING CONTROL DIAGRAM ON SHEET E1.0. 10 PROVIDE 24"w x 36"h x 6"d TELEPHONE CABINET, 3/4" THICK FIRE RETARDANT PLYWOOD. PAINT EXPOSED SIDE WITH ADJACENT WALL COLOR. PROVIDE GROUND BUS, 3/4" CONDUIT WITH (1) #6 GROUND TO LIFER GROUND. PROVIDE QUAD RECEPTACLE AND CIRCUIT AS INDICATED. 11 EXISTING MEANS OF DISCONNECT AND ALL ASSOCIATED ELECTRICAL FOR WATER HEATER TO REMAIN 12 EXISTING NON-FUSED DISCONNECT, WP/GF) RECEPTACLE, AND DUCT MOUNTED SMOKE DETECTOR TO REMAIN. REFER TO PANEL SCHEDULE AND RISER DIAGRAM ON SHEET E3.0 ADDITIONAL INFORMATION. V.I.F. 13 EXISTING RECEPTACLE TO REMAIN 14 PROVIDE POWER AND KEYED SWITCHES FOR ROLLING GRILLE. COORDINATE SPEC AND FINAL' SWITCH LOCATIONS WITH ARCHITECT 15 EXISTING T -STATS TO REMAIN WIN (E) I L SH I 42 L 26 X60" Lit 10 24 I L � 34 I i(TYPICAL) QMI L L 23 20,22 IC3 31,33 mC �mL�3� 1 I _ , EAR fA!LUE-T 18 MI MWU MWU FSLS ' c� .J� 5 (TYPICAL) AHU-1 12 2L 7/29 (TYPICAL) AATV-BENCH AHU-2 L 12 19,21 L CU -2 CU -1 12 12 L L 36/38/40 28/30 MWU i, , Ems:_ :.. LT -S 2 M — — — 20 LT -D CLG LT -S (TYPICAL) MWU L 31,3. a m '-SLT-C T -D 22 LT -ADA --S LT -C (TYPICAL) (TYPICAL) MWU MWU SPT1- 4 19 c _ 1 3 i■' 1 fir' ,.A4,4U, 11 i � ■!_ ■ � SCALE: 1/4"=I'-0" MWU BP L 12 D 12 MPOS L � i17 NOTE: A FIRE ALARM SYSTEM IS REQUIRED FOR THIS LOCATION. T.G.C. TO HIRE A LANDLORD APPROVED FIRE PROTECTION CONTRACTOR TO PROVIDE FIRE PROTECTION PLANS UNDER A SEPERATE SUBMITTAL. RS MWU MWU Ell- � i�-alp (2)D V CLG JE® AWILA 2016 :ENTER ISSUE DATE mco I- m a ; 00 : F-7 j CL mrN m oco m M N m �j C Lr � � P='� (o U) a tL L N O C C Q) C U) C O U ■ C C N O- C O a These drawings/specifications are the property of Kamus + Keller. They are furnished as contract documents only. The seal(s) and signature(s) appy only to the documents to which they affixed, and expressly displatm any responsibility for all other plans, spectfications, estimates, reports or other documents or instruments relating to or intended to be used for any part or parts of the architectural or engineering project. Additionally these drawings and seal(s) shall in no way convey or Imply any time of warranty or certification relating to the performance of products and materials beyond those provided by their respective manufacturer. PROJECT NO. 16.0430.01 DRAWN/REVIEWED GF1BB DATEIISSUE 8.31.2016 SHEET TITLE ELECTRICAL POWER PLAN SHEET NO. E2.1 Cfl M W UJ U) Octc G Jarmo 0 Q WI— W S� �CWzW W =W06 � D <C 0 to (n 0 W 0 00N These drawings/specifications are the property of Kamus + Keller. They are furnished as contract documents only. The seal(s) and signature(s) appy only to the documents to which they affixed, and expressly displatm any responsibility for all other plans, spectfications, estimates, reports or other documents or instruments relating to or intended to be used for any part or parts of the architectural or engineering project. Additionally these drawings and seal(s) shall in no way convey or Imply any time of warranty or certification relating to the performance of products and materials beyond those provided by their respective manufacturer. PROJECT NO. 16.0430.01 DRAWN/REVIEWED GF1BB DATEIISSUE 8.31.2016 SHEET TITLE ELECTRICAL POWER PLAN SHEET NO. E2.1 U) 0 Z v ii W W MOTES BY SYMBOL LI+7-2LBCW--4'—' (3)D (1)T — — — t" CONDUIT FOR POWER PER TABLE. 1" CONDUIT FOR DATA PER TABLE. 2" CONDUIT FOR (1) HDMI„ (2) USB, PER TABLE 0 EXISTING METER BASE AND METER SOCKET TO REMAIN. 0 EXISTING 200 AMP BREAKER TO REMAIN. OEXISTING (4) #3/0 THWN CU, (1) #4 GROUND IN EXISTING CONDUIT TO REMAIN. 4O EXISTING CONDUIT COMPLETE WITH PULL STRING FOR TELEPHONE SERVICE FROM LANDLORD DMARC STUBBED INTO TENANT SPACE. INTERCEPT AND ROUTE CONDUIT TO TENANT PHONE BOARD LOCATION. OEXISTING 60 AMP NON-FUSED DISCONNECT TO REMAIN OEXISTING 30 AMP NON-FUSED DISCONNECT TO REMAIN OEXISTING (2) #8 THWN CU (1) #10 GROUND IN EXISTING CONDUIT OEXISTING (3) #10 THWN CU (1) #10 GROUND IN EXISTING CONDUIT OEXISTING (2) #12 THWN CU (1) #10 GROUND IN EXISTING CONDUIT W REF. WIREMOLD I -1 wLIJ 2" CONDUIT STUB -UP BEHIND FIXTURE (OUTSIDE OF WALL), FLUSH WITH CONCRETE I ` = t .EGIRAND RFB4E 2,CONDUIT STgB-UP NEXT TO LOOR BOX, PE TABLE GENERAL NOTES 1. 120/208 VOLT 4 WIRE EXISTING ELECTRICAL SERVICE NOTE: RECEPTACLES @ BACKWRAP AND LEARNING TABLE TO BE ON A SINGLE 20 AMP DEDICATED CIRCUIT. DO NOT ADD OTHER RECEPTACLES TO CIRC. NOTE: IF LEARNING TABLES ARE TO BE TEMPORARILY USED AS POS STATIONS, THE 2" CONDUIT SHOWN IN ENLARGED PLAN IS REQUIRED IN ORDER TO PROVIDE HDMI AND USB CORDS AND AMPLIFIER FROM THE BACKWRAP TO THE LEARNING TABLE. THE HDMI, USB, AND AMPLIFIER SHOUDL BE ORDERED THROUGH GRAINGER AS REQUIRED. POWER/ DATA ENLARGED PLAN @ BCW & LT CU -1—M5 I CU-2� 7 8 AHU-1 II I 7 AHU-2 I II 119 III TC I EXISTING PANEL i Cl I I L ----J Ifl JAM!"', I Imo; 14+4 5r• i 2. TENANTS GENERAL CONTRACTOR SHALL PROVIDE AND INSTALL ALL COPPER CONDUCTORS WHEN NEW IS REQUIRED 3. VERIFY ALL EXISTING CONDITIONS IN FIELD. ALL UPGRADES REQUIRED BY CODES, LANDLORD OR TENANT SHALL BE BY TENANT AT TENANTS EXPENSE. 4. CONTRACTOR TO VERIFY ALL METERING REQUIREMENTS WITH LANDLORD AND LOCAL UTILITY PRIOR TO BID. 5. CONTRACTOR TO VERIFY EXACT DISTANCE AND ROUTING OF SERVICE FEEDERS FROM LANDLORD DISTRIBUTION/ SERVICE EQUIPMENT TO TENANT SPACE PRIOR TO BIDDING. HOMERUNS AND BRANCH WIRING FOR 20 AMP CIRCUITS SHALL ELECTRICAL LOAD BE AS FOLLOWS: LENGTH CIRCUIT WIRE SIZE HOMERUN WIRE SIZE 1 FT TO 50FT NO.12 AWG NO.12 AWG 51 FT TO 75FT NO.12 AWG NO.10 AWG 76FT TO 120FT NO.10 AWG NO.8 AWG 121 FT TO 190FT NO.10 AWG NO.6 AWG 191 FT TO 30OFT NO.10 AWG NOA AWG SCALE: N.T.S. NOTE REGARDING EXAMINATION OF PREMISES/FIELD CONDITIONS: PRIOR TO SUBMITTING PROPOSALS FOR THE WORK, EACH BIDDER IS REQUIRED TO HAVE EXAMINED THE PREMISES AND VERIFY THE EXISTING FIELD CONDITIONS. THE EXISTING CONDITIONS HAVE BEEN EXAMINED IN THE FIELD BY TENANT REPRESENTATIVE'S AND ARE BELIEVED TO BE DEPICTED IN A ACCURATE MANNER AS THEY EXIST. IF THE BIDDER FINDS THAT THAT THERE ARE DISCREPANCIES BETWEEN THE EXISTING CONDITIONS AND THE INFORMATION SHOWN ON THESE DRAWINGS, THEY SHOULD NOTIFY THE TENANTS REPRESENTATIVE OF THOSE DISCREPANCIES. IF THESE INSTRUCTIONS ARE IGNORED, THE CONTRACTOR SHALL BE RESPONSIBLE FOR FURNISHING ALL THE EQUIPMENT REQUIRED FOR A COMPLETE AND FUNCTIONING ELECTRICAL SYSTEM AT NO ADDITIONAL COST TO TENANT. NOTE REGARDING ELECTRICAL DISTRIBUTION SYSTEM: THE ELECTRICAL RISER DIAGRAM INDICATED HAS BEEN PROPERLY DESIGNED TO ACCOMMODATE TENANTS POWER REQUIREMENTS AND MEETS ALL APPLICABLE BUILDING CODES. IT IS THE RESPONSIBILITY OF THE G.C. TO VERIFY ALL EXISTING CONDITIONS AND DETERMINE IF ANY EXISTING EQUIPMENT AND WIRING IS SUITABLE FOR REUSE IN THE SYSTEM PRIOR TO BIDDING. G.C. SHALL PERFORM ALL WORK NECESSARY TO RESULT IN A COMPLETE AND LEGAL INSTALLATION INCLUDING THE UPGRADING AND/OR MODIFICATION OF THE EXISTING SERVICE FEEDERS, CONDUITS AND TAP -INS EXTENDED TO PROPER POINT OF ORIGIN AS COORDINATED WITH THE LANDLORD. NOTES: I TOTAL AMPS @1201208V 3PH 128.24 1. 100% OF FIRST 10,000 WATTS, PLUS. 50% OF REMAINING LOAD. 2. 100% OF A/C LOAD (COOLING VS HEATING) PLUS 25% OF LARGEST MOTOR. REVIEWED FOR COMPLIANCE 1 'ITH NFPA 7n A NEC SEP 14: 2016 City of-T'ukWl1a BUILDING DIVISInN RECEIVED CITY OF TUKWILA SEP 0 8 2016 PERMIT CENTER ISSUE DATE T S Sr r 00 T ti C 0 r rN' CL o C 00 m CO m 9 C m ur):n) > Lo�� L ai CZ c a� t» r_ 0 0 c c cv CL C 0 ELECTRICAL LOAD S MMA■ iY 1201208V 3PH - 4W LOAD DESCRIPTION CONNECTED VA FACTOR DEMAND VA VOLTAGE PHASE LIGHTING 4,537 1.25 5,671 120 1 RECEPTACLES 9,280 NOTE # 1 9,280 120 1 SHOW WINDOW RECEPTACLE: 0 1.25 0 120 1 MECHANICAL 23,984 NOTE # 2 24,715 208 3 SIGN LIGHTING 1,200 1.25 1,500 120 1 WATER HEATERS 31600 1.25 4,500 120 1 MISCELLANEOUS 500 1.00. 500 120 1 TOTAL 43,101 46,166 208 3 NOTES: I TOTAL AMPS @1201208V 3PH 128.24 1. 100% OF FIRST 10,000 WATTS, PLUS. 50% OF REMAINING LOAD. 2. 100% OF A/C LOAD (COOLING VS HEATING) PLUS 25% OF LARGEST MOTOR. REVIEWED FOR COMPLIANCE 1 'ITH NFPA 7n A NEC SEP 14: 2016 City of-T'ukWl1a BUILDING DIVISInN RECEIVED CITY OF TUKWILA SEP 0 8 2016 PERMIT CENTER ISSUE DATE T S Sr r 00 T ti C 0 r rN' CL o C 00 m CO m 9 C m ur):n) > Lo�� L ai CZ c a� t» r_ 0 0 c c cv CL C 0 These drawings/specifications are the property of Kamus + Keller. They are furnished as contract documents only. The seal(s) and signature(s) apply only to the documents to which they affixed, and expressly dispiaim any responsibility for all other plans, specifications, estimates, reports or other documents or Instruments relating to or intended to be used for any part or parts of the architectural or engineering project. Additionally these drawings and seal(s) shall in no way convey or imply any time of warranty or certification relating to the performance of products and materials beyond those provided by their respective manufacturer. III I PROJECT NO. 16.0430.01 DRAWN/REVIEWED GFIBB DATE/ISSUE 8.31.2016 SHEET TITLE ELEC PANEL SCHEDULES & RISER DIAGRAM I,I�IIII VIII SHEET NO. E3.0 (0 Ir— co M W W U3 OQ_j°r° _i OO 0ol WW�< J z W WW UW Z J UI~— °6 Z) I— W d�o� U) O 00 (N These drawings/specifications are the property of Kamus + Keller. They are furnished as contract documents only. The seal(s) and signature(s) apply only to the documents to which they affixed, and expressly dispiaim any responsibility for all other plans, specifications, estimates, reports or other documents or Instruments relating to or intended to be used for any part or parts of the architectural or engineering project. Additionally these drawings and seal(s) shall in no way convey or imply any time of warranty or certification relating to the performance of products and materials beyond those provided by their respective manufacturer. III I PROJECT NO. 16.0430.01 DRAWN/REVIEWED GFIBB DATE/ISSUE 8.31.2016 SHEET TITLE ELEC PANEL SCHEDULES & RISER DIAGRAM I,I�IIII VIII SHEET NO. E3.0