Loading...
HomeMy WebLinkAboutPermit EL16-0860 - 85C BAKERY - SERVICE85C BAKERY 1341 SOUTHCENTER MALL ELl 6=0860 °��r/sem • Department of Community Development ,', • 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Inspection Request Line: 206-438-9350 Web site: http://www.TukwilaWA.Rov ELECTRICAL PERMIT Parcel No: 9202470090 Permit Number: EL16-0860 Address: 1y340 SOUTHCENTER MALL Issue Date: 10/5/2016 i*f Permit Expires On: 4/3/2017 Project Name: 85C BAKERY Owner: Name: WESTFIELD PROPERTY TAX DEPT Address: PO BOX 130940, CARLSBAD, WA, 92013 Contact Person: Name: PETE MOLNER Phone: (253) 872-5553 Address: 7056 S 220TH ST, KENT, WA, 98032 Contractor: Name: SEA TAC ELECTRIC INC Phone: (253) 872-5553 Address: 7056 S 220TH ST, KENT, WA, 98032- 1910 License No: SEATAE1077RW Expiration Date: 12/17/2017 Lender: Name: Address: DESCRIPTION OF WORK: ELECTRICAL SERVICE INSTALLATION WORK PER PLANS. INCLUDE THE REMOVAL, RELOCATION AND INSTALLATION FOR ELECTRICAL SYSTEMS PERTAINING TO THE AFOREMENTIONED SCOPE OF WORK. Valuation of single family: $0.00 Fees Collected: $974.62 Valuation of mf/comm: $37,000.00 Type of Work: SERV CHNG Electrical Service Provided by: PUGEST SOUND ENERGY Water District: TUKWILA Sewer District: TUKWILA Current Codes adopted by the City of Tukwila: International Building Code Edition: 2015 National Electrical Code: 2014 International Residential Code Edition: 2015 WA Cities Electrical Code: 2014 International Mechanical Code Edition: 2015 WAC 296-46B: 2014 Uniform Plumbing Code Edition: 2015 WA State Energy Code: 2015 International Fuel Gas Code: 2015 Permit Center Authorized Signature: I hearby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this development permi nd agree to the conditions attached to this permit. Signature: Date: Print Name: This permit shall become null and void if the work is not commenced within 180 days for the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. PERMIT CONDITIONS: 1: 'ELECTRICAL PERMIT CONDITIONS' 2: A copy of the electrical work permit shall be posted or otherwise made readily accessible to the Electrical Inspector at each work site. 3: Approved plans shall be maintained at the construction site and shall be readily available to the Electrical Inspector. 4: All electrical work shall be in accordance with NFPA 70 - NEC, and requirements for electrical installations, Chapter 296-46B WAC. 5: When any portion of the electrical installation is to be hidden from view by permanent placement of parts of the building, such equipment shall not be concealed until it has been inspected and approved by the Electrical Inspector. 6: The issuance of an electrical work permit shall not be construed to be a permit for, or an approval of, any violation of the provisions of the electrical code or other ordinances of the jurisdiction. Permits or related documentation that presumes to grant this authority are therefore not valid. 7: Any change in the scope of work described by the electrical work permit shall require additional work permits. Where approved plans have been issued, revisions to the plans and additional review may be required. PERMIT INSPECTIONS REQUIRED Permit Inspection Line: (206) 438-9350 2100 ELECTRICAL FINAL 7003 ROUGH -IN ELECTRICAL 7002 SERVICE 7001 UNDERGROUND/SLAB oi CITY OF TUKWIi Community Development Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 �* http://www.TukwilaWA.gov Electrical Permit No. Project No. Date Application Accepted: deo Date Application Expires: V - use ELECTRICAL PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. "Please Print" SITE LOCATION 2800 SOUTHCENTER MALL l 040 King Co Assessor's Tax No.: Site Address: 9MSOUTHCENTER MALL Suite Number: Floor: Tenant Name: PROPERTY OWNER Name: Address: City: State: Zip: CONTACT PERSON — person receiving all project communication Name: PETE MOLNER Address: 7056 S. 220TH STREET City: KENT State: WA Zip: 98032 Phone: (253) 872-5553 Fax: (253) 872-4112 Email: pete.molner@seatacelectric.com Valuation of Project (contractor's bid price): $ Iow Scope of Work (please provide detailed information): New Tenant: ❑✓ .....Yes EJ.. No ELECTRICAL CONTRACTOR INFORMATION Company Name: SEA -TAC ELECTRIC, INC. Address: 7056 S. 220TH STREET City: KENT State: WA Zip: 98032 Phone: (253) 867-2354 Fax: (253) 872-4112 Contr Reg No.: SEATAEI077RW Exp Date: 12/01/2016 Tukwila Business License No.: 01-212 ELECTRICAL SERVICE INSTALLATION WORK PER PLANS. INCLUDE THE REMOVAL, RELOCATION AND INSTALLATION OF ELECTRICAL SYSTEMS PERTAINING TO THE AFOREMTINOED SCOPE OF WORK. Will service be altered? 0 Yes ❑ No Type of Use: COMMERCIAL Type of work: ❑ New ❑ Addition 0 Service Change ❑ Low Voltage ❑ Generator ❑ Fire Alarm Property Served by: ® Puget Sound Energy ❑ Seattle City Light H:\Applications\Forms-Applications On Line\201 I Applications0ectrical Permit Application Revised 8-9-1 l.docx Revised: August 2011 bh Adding more than 50 amps? 0 Yes ❑ No ❑ Remodel ® Tenant Improvement ❑ Telecommunication ❑ Temporary Service Page 1 of 2 RESIDENTIAL NEW RESIDENTIAL SERVICE ❑ New single family dwellings ................................... $152.85 (including an attached garage) ❑ Garages, pools, spas and outbuildings ........................$81.90 ea ❑ Low voltage systems (alarm, furnace thermostat) ................................ $59.85 ea RESIDENTIAL REMODEL AND SERVICE CHANGES ❑ Service change or alteration ...................................... $81.90 (no added/altered circuits) ❑ Service change with added/altered circuits.................$81.90 number of added circuits ....................... $11.55 ea ❑ Circuits added/altered without service change ........... $54.60 (up to 5 circuits) ❑ Circuits added/altered without service change ........... $54.60 (6 or more circuits) ............................................... $7.65 ea ❑ Meter/mast repair ....................................................... $68.25 ❑ Low voltage systems ................................................. $59.85 (alarm, furnace thermostat) PERMIT APPLICATION NOTES - MULTI -FAMILY AND COMMERCIAL Fees are based on the valuation of the electrical contract. MISCELLANEOUS FEES ❑ Temporary service (residential) ................................. $63.00 ❑ Temporary service (generator) ................................... $78.75 ❑ Manufactured/mobile home service ........................... $84.00 (excluding garage or outbuilding) ❑ Carnivals....................................................................$78.75 Number of concessions ......................... $10.50 ea Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The Building Official may grant one extension of time for an additional period not to exceed 90 days. The extension shall be requested in writing and justifiable cause demonstrated. I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER OR ELECTRICAL CONTRACTOR: Signature: Print Name: PETE MOLNER Mailing Address: 7056 S. 220TH STREET H:\Applications\Form-Applications On Line\2011 Applications\Electrical Permit Application Revised 8-9-1 I.doex Revised: August 2011 bh Date: 9/16/2016 Day Telephone: (253) 872-5553 KENT WA 98032 city state Zip Page 2 of 2 Date Paid: Monday, October 31, 2016 Paid By: PETER MOLNER Pay Method: CREDIT CARD 072865 Printed: Monday, October 31, 2016 8:47 AM 1 of 1 SYSTEMS DESCRIPTIONS PermitTRAK ACCOUNT QUANTITY PAID $787.19 EL16-0860 Address: 1350 SOUTHCENTER MALL Apn: 9202470090 $787.19 ELECTRICAL $749.70 PERMIT FEE MULTI-FAM/COMM 13000.322.101.00.00 0.00 $749.70 TECHNOLOGY FEE $37.49 TECHNOLOGY FEE TOTAL. R9569 R000.322.900.04.00 0.00 $37.49 Date Paid: Wednesday, October 05, 2016 Paid By: PETER MOLNER Pay Method: CREDIT CARD 005837 Printed: Wednesday, October 05, 2016 8:08 AM 1 of 1 SY57EM5 Date Paid: Tuesday, September 20, 2016 Paid By: SEA TAC ELECTRIC Pay Method: CREDIT CARD 096100 Printed: Tuesday, September 20, 2016 3:31 PM 1 of 1 SY57EM5 INSPECTION RECORDJ6-1L,6 �-✓ Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd.., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Project: Mc • Type of Inspection: Address: 3 e Date Called: Special Instructions: i-0® Date Wanted:a. p.m. Requester: Phone No: Approved per applicable codes. !__J Corrections required prior to approval. LAJ (Inspector: `--7141) fcl,[A,)A1 IDate: 0471., f� REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. INSPECTION RECORD Retain a copy with permit (� INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Project: r Type of Inspection: Address:3 �—o Date Called: Special Instructions: Date Wanted: > a.m. Requester: Phone No: Approved per applicable codes. 11 Corrections required prior to approval. LJ paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 4 Permit Inspection Request Line (206) 438-9350 Project: (� Type of Inspection: r Address: � � � Date Called: Special Instructions: PkPhone Date Wanted: a.m. / i��— Requester: Lo� No: Approved per applicable codes. Corrections required prior to approval. COMMENTS: 1' LJ paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. OFF HOURS INSPECTION Reimbursement authorization/approval to conduct inspection activities during off hours. Date: 16 I31 //4p Requested By: f—&,/ , No lW"Pr Firm/Company: felcC, (a�(_ IL&C1111-14L Inspection Information Project Name: 915- Project 5 Permit Number: Et -i & — 0 O cyo Project Address/Location: 131-1 / S/�'ICJ Yt `�C—'� 04Q—I( Requested Date for Inspection: l � �Co f /� d RequesteTime: �� o� AQ PM Contact Name: F'0l 6 A40 INer Phone Number: r C''�`� - 4172— Special 'l%Z Special Conditions for Consideration: ** Contractor will be charged a minimum for three (3) hour inspection time for any off -hours inspection work at $100.00 per hour (minimum total of $300.00). This is to be paid at the time of request. ** The undersigned, as an authorized representative of the above firm, hereby agrees to reimburse the City for its overtime inspections on the above referenced project. A separate invoice will be issued for all inspection time in excess of three (3) hours. Signature: /,/ Printed Name: ��e City Use Only: Approved: Disapproved: Date of Approval/Disapproval: Authorized Reviewer: W:\Permit Center\Templates\Forms\off hours inspection 1-2015.docx Revised: January 1, 2015 Date: RECEIVED CITY Of TUKWILA. PERMIT CENTER Paid: Receipt No: Remarks: 4/3/2017 PETE MOLNER 7056 S 220TH ST KENT, WA 98032 City of Tukwila Allan Ekberg, Mayor Department of Community Development Jack Pace, Director RE: Permit No. ELI 6-0860 85C BAKERY 1350 SOUTHCENTER MALL Dear Permit Holder: In reviewing our current records, the above noted permit has not received a final inspection by the City of Tukwila Building Division. Per the International Building Code, International Mechanical Code, Uniform Plumbing Code and/or the National Electric Code, every permit issued by the Building Division under the provisions of these codes shall expire by limitation and become null and void if the building or work authorized by such permit has not begun within 180 days from the issuance date of such permit, or if the building or work authorized by such permit is suspended or abandoned at any time after the work has begun for a period of 180 days. Your permit will expire on 5/6/2017. Based on the above, you are hereby advised to: 1) Call the City of Tukwila Inspection Request Line at 206-438-9350 to schedule for the next or final inspection. Each inspection creates a new 180 day period, provided the inspection shows progress. s•Tx 2) Submit a written request for permit extension to the Permit Center at least seven(7) days before it is due to expire. Address your extension request to the Building Official and state your reason(s) for the need to extend your permit. The Building Code does allow the Building Official to approve one extension of up to 180 days. If it is determined that your extension request is granted, you will be notified by mail. In the event you do not call for an inspection and/or receive an extension prior to 5/6/2017, your permit will become null and void and any further work on the project will require a new permit and associated fees. Thank you for your cooperation in this matter. Sincerely, WA Rachelle Ripley Permit Technician File No: ELI 6-0860 6300 Southcenter Boulevard Suite #100 • Tukwila, Washington 98188 9 Phone 206-431-3670 9 Fax 206-431-3665 4ERMIT COORD COPY... PLAN VIEW/ROUTING SLIP PERMIT NUMBER: EL16-0860 DATE: 09/20/16 PROJECT NAME: 85C BAKERY SITE ADDRESS: 1350 SOUTHCENTER MALL. #100 1 Original Plan Submittal Revision # before Permit Issued Response to Correction Letter # Revision # after Permit Issued DEPARTMENTS: hVIP Buil Division Fire Prevention ❑ Planning Division ❑ Public Works ❑ Structural ❑ Permit Coordinator ❑ PRELINIINARY REVIEW: DATE: 09/22/16 Not Applicable ❑ Structural Review Required ❑ (no approval/review required) REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: DUE DATE: 10/20/16 Approved ❑ Approved with Conditions ❑ Corrections Required ❑ (corrections entered in Reviews) Notation: REVIEWER'S INITIALS: Denied ❑ (ie: Zoning Issues) DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: 12/18/2013 SEA TAC ELECTRIC INC Home Espafiol Contact Safety & Health Washington State'Department of Labor Undustries SEA TAC ELECTRIC INC Page 1 of 6 Search L&II�r'r:+ a1-ZIndex Help My L& Claims & Insurance Workplace Rights Trades & Licensing Owner or tradesperson 7056 S 220TH ST 601 510 212 KENT, WA 98032 Principals p 253-872-5553 HARGREAVES, TOM, PRESIDENT KING County JORDAN, TOM, VICE PRESIDENT M BEAN, ERIC, SECRETARY HARGREAVES BEAN, ERIC, TREASURER THOMAS R HARGREAVES; HARGREAVES, TOM, AGENT TOM JORDAN; HARGREAVES, KATHERINE, SECRETARY (End: 12/10/2008) Electrical Contractor BURKS, ROY, VICE PRESIDENT (End: 12/15/1995) Doing business as SEA TAC ELECTRIC INC WA UBI No. Business type 601 510 212 Corporation Governing persons KATHERINE M HARGREAVES THOMAS R HARGREAVES; TOM JORDAN; License Verify the contractor's active registration / license ! certification (depending on trade) and any past violations. Electrical Contractor Active. Meets current requirements. License specialties GENERAL License no. SEATAE1077RW Effective — expiration 12/16/1993-12/17/2017 Designated administrator ................. Jordan, Thomas License type Master Electrician Bond ................. DEVELOPERS SURETY & INDEM CO Bond account no. 798649C Received by L&I 12/03/2008 Active. Meets current requirements. License no. JORDAT'914LR $4,000.00 Effective date 12/16/2008 Help us improve https://secure.lni.wa.gov/verify/Detail.aspx?UBI=601510212&LIC=SEATAE1077RW&SAW= 10/5/2016 NU It: baseo on I HHV Insulation, tM i conoun ana unapier v, !ante 4 and Table' 5a fbr compact AL wire, of the NEC, 2008 edition. - Indicates acceptable overcurrent device rating for single feeder. This rating shall not be used for sizing parallel feeders. i I-- '* In-dicates overcurrent protective dev~ce rating that may be used forthis feeder __, _ _. _ :_ _.._ . _._ . _._ _ __-__ ._.________-- The Contractor shall install feeder size indicated even if Code allows smaller to be used. i GRADE UTILITY DEMAND R#Z017452912 ------ -- .._DEMAND ---- 200.64 i EquipmentAllowances ------ HP E4UIP EQUIP A ---- -- --NEC -- NEC Description I HP V PH KW KW I A KW I QTY DEMAND REFERENCE TOTAL TENANT SPACE __.___._..____. _._ 72.05- KVA ELL1-1 TENANT SPACE FULL LOAD 208 3 200 7205 1 100% PAN ( ) J 0 .0 100 0 05 KVA PANEL LI -2 TENANT SPACE (FULL LOAD) I 208 3 I 20 72 5 f 1 % 72. TOTAL ->422,77 KVA - 56,8.52 A@ ;480V EXTERIOR INTERIOR NEMA 3R NEMA 1 PANEL XFMR vw XFMR vw H1 M o #6G #6G I o 0 i PANEL PANEL L1-1 L1-2 AREA OF WORK 200A 200A 40 MCB MCB I LOAD SIDE FEED TO ' INTERCEPT EXISTING SPARE I I CONDUITS IN BUSS GUTTER I t NEW r_____________L__________, EXISTING SPARE CONDUITS FEEDER SCHEDULE ALUMINUM PSE METER EMT AMPACITYI N co ID NO RACEWAY WIRE COUNT & SIZE OCP SIZE NOTES 03N 314" 4 - #8, 1#8 G. 30/30 60 -deg rating 03 314" 3-#81#8G. 30/30 60 -deg ratio 04N 1" 4 #6, 1#8 G. 40/40 60 -deg rating - 04 1" _ . -- 3 - #6, 1#8 G. _._ -- 40 / 40 -- - - ---- -- 60 -deg rating --_....- .---- - ----- 60 -deg rating 05N 1 1/4" 4 #4, 1#8 G. - #4_, 1#8 G. 55/50 05 1° 55/5060 -deg rating 06N-- _ 1 1/4" _3 - 4 - #3, 1#8 G. -- - 65/60 - ---- 60 -deg rating 06 1 1/4" 3 - #3, 1#8 G. 65/60 60 -deg rating DISC CT Z Y TAP CAN - � #2, 1#6 G. _ - 75/70 60 -deg rating 08N 1 114 4 #1 1#6 G 85180. 85/80 60 -de rattn 60 -deg rating 8 1 914" 3 #1, 1#6 G 120! 100 - 75 deg.rating 10N#1/0, 1#6 G. 10 1 1J2" 3 - #1/0, 1#6 G. 120/100- 75 -deg rating---­ ating4 3PH 4W 4_41M #1/6, 14-4 G. _3-#i/01_1#4G. 120 / 110 75 deg rating 12 1 112' 1201110 75 -deg rating 13N 2" 4 #2/0 1 #4 G. 135/125 75 -deg rating 13 2" 3 - 4-21-6, 1-#4- G. 135 / 125 75 deg rating 15N 2" 4 - #310, 1 #4 G. 155 / 150 75 -deg rating 15 2 3 #310 1 #4 G 155/150 75 -deg rating 18N 2 112" -4----kill 1 ik G. 1801 175 v - 75 -deg rating #410, 1 ig G. 180 /- 175 75 -deg rating 20N 2 1/2" 4-250kcmil, 1 #4 G. 205 / 200 75 -deg rating _ ___._____.-_ 20 ._ 2 112" _. _- __- #4 G__. 3-250kcmil, 1 #4 G. __._._ 205 / 200 -- ---_ ___ _...-_.__-- 75 -deg rating 22N -2 1/2" 4-300kcmil, 1 #2 G.230 J 225 75 -deg rating - 22 2 112" 3-300kcmil, 1 #2 G. - - 230 / 225 75 -deg rating 25N 3" 4-350kcmil, 1 #2 G. 250/250- 75�deg rating 25 2 1/2" 3-350kcmil, 1 #2 G. 250/250 - - 75 -deg rating 27N 3" 4-400kcmil, 1 #2 G. _ 270 / 250 75 deg rating 27 3400kcmil, 1 #2 G. -2-112F 270/250 75 -deg rating 30N _ 3" 4 50okcmil, 1 #2 G. 310/300 75 -deg rating 30 -y- --s -566-cmil, 1 #2 G. 3101300 75 -deg ratio 34N 3112" 4-600kcmil, 1 #1 G. 340--/-300--- 75 degxating 34 3" 3 600kcmil, 1 #1 G. 34-0--/ 300 75 -deg rating 40N (2) 2112" 4-250kcmil, 1_#1 G.4101400 75 -deg rating 1 #1 G.__ __ -4101400 - - 75 -deg rating - 45N 4-300kcmil, 1 #110 G. 4601450 75 deg rating ---------- - - ---. _. - -- --- -- -- - - 3-300kcmil, 1 4-1/0 G. ____4_6_0_ ._.... - ._/4_ / 450- - -- -----_-_ - -- 75 -deg rating 50N -(2} 3" 4-350kcmil, 1 #1/O G. - 500 -/-5--0-0 - - ---75 deg rating -- 50 3-350kcmil, 1 #1/0 G. 500/500 75 -deg rating 4-500kcmil, 1 #210 G. 620/600 75 -deg rating 60 2 3" 3-500kcmil, 1 #2/0 G. 6201600 75 -de ratio 75N ___(3)T 4-350kcmi1, 1 #310 G. 7501750 75 -deg rating 75 {3)21!2" 3-350kcm 1, 1 43/013. 750! 756 754eg rating 80N (3) 3" 4-460kcmil, 1 #3/0 G. 810/800-- 75 deg rating 80 {3) 21/2" 3 400kcmil, 1 #3/0 G. 4-500kcmil, 1_# G. 810 / 800 75 -deg rating 75-deg_rating 90N (3) 3" 930! 900 3-500kcmil, 1#4/0 G. 930 / 900 75 deg rating 100N (3) 21/2" 4-600kcmit, 1 #4/0.13. 1020 / 1000 75-deg_rating (4) 3" mi 1, 1#410 G. -1020 / 1000 -______ 75 deg rating 120N 41500kcmil, 1 #250 G. 1240 / 1200 75 -deg rating 120 (4} $" 3-500kcmil, 1 #250 G _ 1240 ! 1200 75 -deg rating 4500kcmil, 1 #350 G 1550/1500 75 -deg rating 150 (5) 3" 3-500kcmil, 1 #350 G. 1550/1500 75 -deg rating 160N (6) 3" 4-400kcmil, 1 #350 G. 1620/1600 75 -deg rating 160 (6)2 112" 3 40okcmi1, 1 #350 G- 1620/1600 75 -deg rating 20ON (6)2 1/2" 4-600kcmil, 1 #400 G. 75 -deg rating_ _ 200 - 3-600kcmil, 1 #400 G _ _204012000 2040/2000 75 -deg rating NU It: baseo on I HHV Insulation, tM i conoun ana unapier v, !ante 4 and Table' 5a fbr compact AL wire, of the NEC, 2008 edition. - Indicates acceptable overcurrent device rating for single feeder. This rating shall not be used for sizing parallel feeders. i I-- '* In-dicates overcurrent protective dev~ce rating that may be used forthis feeder __, _ _. _ :_ _.._ . _._ . _._ _ __-__ ._.________-- The Contractor shall install feeder size indicated even if Code allows smaller to be used. i GRADE UTILITY DEMAND R#Z017452912 ------ -- .._DEMAND ---- 200.64 i EquipmentAllowances ------ HP E4UIP EQUIP A ---- -- --NEC -- NEC Description I HP V PH KW KW I A KW I QTY DEMAND REFERENCE TOTAL TENANT SPACE __.___._..____. _._ 72.05- KVA ELL1-1 TENANT SPACE FULL LOAD 208 3 200 7205 1 100% PAN ( ) J 0 .0 100 0 05 KVA PANEL LI -2 TENANT SPACE (FULL LOAD) I 208 3 I 20 72 5 f 1 % 72. TOTAL ->422,77 KVA - 56,8.52 A@ ;480V EXTERIOR INTERIOR NEMA 3R NEMA 1 PANEL XFMR vw XFMR vw H1 M o #6G #6G I o 0 i PANEL PANEL L1-1 L1-2 AREA OF WORK 200A 200A 40 MCB MCB I LOAD SIDE FEED TO ' INTERCEPT EXISTING SPARE I I CONDUITS IN BUSS GUTTER I t NEW r_____________L__________, EXISTING SPARE CONDUITS TO unuTr i SPLICE VAULT 2---- - . -LOOPED � swIrcH XFMR VAULT OW TERMINATION (TYP) EXISTING OUTDOOR SWITCH 1200A, 480Y/277V 3PH, 4W NEMA 3R EXISTING SERVICE FEEDERS: (4) 4" PVC -40 (4) 500KCMIL AL (EACH) ONE -LINE RISER DIAGRAM SCALE: NTS GENERAL NOTES: 1. ALL CONDUCTORS ARE #12 AWG CU UNLESS NOTED OTHERWISE. MC FEEDER CAN BE USED WHERE APPROPRIATE AND AT CONTRACTOR'S DISCRETION. MC FEEDER SHALL BE SIZED PER NEC REQUIREMENTS. 2. EQUIPMENT SHOWN BOLD IS NEW. 3. EQUIPMENT SHOWN DASHED IS EXISTING. 4. FIELD VERIFY EXISTING CONDITIONS PRIOR TO CONSTRUCTION. 5. ALL SWITCHBOARDS AND PANELBOARDS SUPPLIED BY A FEEDER SHALL BE MARKED TO INDICATE THE DEVICE OR EQUIPMENT WHERE THE POWER SUPPLY ORIGINATES PER NEC 408.4(B). 6. FEEDERS ARE ALUMINUM WITH THHN/THWN INSULATION. 7. PROVIDE PULL BOXES AS REQUIRED BY THE NEC. 8. SHORT CIRCUIT CURRENTS LESS THAN 10,000 AIC FOR 208V PANELS AND 14,000 AIC FOR 480V PANELS ARE NOT SHOWN. 9. THE ONE -LINE DIAGRAM IS DIAGRAMMATIC AND DOES NOT SHOW THE ACTUAL ROUTING OF RACEWAYS. 10. FOR TWO SECTION PANELS PROVIDE FULL SIZE FEEDER CONNECTIONS FROM SECTION 1 TO SECTION 2. 11. NOT ALL CIRCUIT BREAKERS ARE SHOWN, REFER TO PANEL AND SWITCHBOARD SCHEDULES FOR OTHER LOADS SERVED, AND SPARE CIRCUIT BREAKERS. FILE COPY Permit No. 1V4/ -_ 0 tW Plan raview ap _,roval is subject to errors and omissions. Approval of construction documents does not authorize the violation of any adopted code or ordinance. Receipt of approved Field Copy and conditions is acknowledged: By: Date: _ /Lo �._..� City of Tukwila BUILDING DIVISION - fiEVISIt__NS _. No Changes shill ho made to the scope of "►o, mithout Prior approval of TUJ<Wlia Building Division. NOTE: Revisions will require anew plan submittal and may include additional plan review fees. I :2QUIR--;z0 FOR, Efolvecttanicei D lectricat PGa mbing s Piping . City of Tukwila RECEIVED CITY OF TUKWILA SEP 2 0 2016 PERMIT CENTER M L L L PSE METER N N co M LO \N.. M LO v UZ Z EXISTING BUSS GUTTER 1 Z O LL _ 1200A, 480Y/277V 3PH, 4W j U NEMA 3R W W r----------------� ' SVC "_I W~ NEW N Mp EXISTING = OLr) 00 rn 'S DISC CT Z Y TAP CAN , � ENCLOSURE;1200A,400A I FUSED 480Y/277V (6) 2" CONDUIT 3PH 4W l (4) 3/0 (EACH) , NEMA 3R (1) 3/OG (EACH) I I L___ ___ __ ___J I I I1 r�\� -1� I 40 40 ; L i r� l ¢ ' ; O�5 i O ------------------------------� EXISTING PSE ( I I O i I CD i i CV 1 I UTILITY XFMR I I I I------------"�------------ ; 1 _ > I I< >11< I I I I I 1 TO unuTr i SPLICE VAULT 2---- - . -LOOPED � swIrcH XFMR VAULT OW TERMINATION (TYP) EXISTING OUTDOOR SWITCH 1200A, 480Y/277V 3PH, 4W NEMA 3R EXISTING SERVICE FEEDERS: (4) 4" PVC -40 (4) 500KCMIL AL (EACH) ONE -LINE RISER DIAGRAM SCALE: NTS GENERAL NOTES: 1. ALL CONDUCTORS ARE #12 AWG CU UNLESS NOTED OTHERWISE. MC FEEDER CAN BE USED WHERE APPROPRIATE AND AT CONTRACTOR'S DISCRETION. MC FEEDER SHALL BE SIZED PER NEC REQUIREMENTS. 2. EQUIPMENT SHOWN BOLD IS NEW. 3. EQUIPMENT SHOWN DASHED IS EXISTING. 4. FIELD VERIFY EXISTING CONDITIONS PRIOR TO CONSTRUCTION. 5. ALL SWITCHBOARDS AND PANELBOARDS SUPPLIED BY A FEEDER SHALL BE MARKED TO INDICATE THE DEVICE OR EQUIPMENT WHERE THE POWER SUPPLY ORIGINATES PER NEC 408.4(B). 6. FEEDERS ARE ALUMINUM WITH THHN/THWN INSULATION. 7. PROVIDE PULL BOXES AS REQUIRED BY THE NEC. 8. SHORT CIRCUIT CURRENTS LESS THAN 10,000 AIC FOR 208V PANELS AND 14,000 AIC FOR 480V PANELS ARE NOT SHOWN. 9. THE ONE -LINE DIAGRAM IS DIAGRAMMATIC AND DOES NOT SHOW THE ACTUAL ROUTING OF RACEWAYS. 10. FOR TWO SECTION PANELS PROVIDE FULL SIZE FEEDER CONNECTIONS FROM SECTION 1 TO SECTION 2. 11. NOT ALL CIRCUIT BREAKERS ARE SHOWN, REFER TO PANEL AND SWITCHBOARD SCHEDULES FOR OTHER LOADS SERVED, AND SPARE CIRCUIT BREAKERS. FILE COPY Permit No. 1V4/ -_ 0 tW Plan raview ap _,roval is subject to errors and omissions. Approval of construction documents does not authorize the violation of any adopted code or ordinance. Receipt of approved Field Copy and conditions is acknowledged: By: Date: _ /Lo �._..� City of Tukwila BUILDING DIVISION - fiEVISIt__NS _. No Changes shill ho made to the scope of "►o, mithout Prior approval of TUJ<Wlia Building Division. NOTE: Revisions will require anew plan submittal and may include additional plan review fees. I :2QUIR--;z0 FOR, Efolvecttanicei D lectricat PGa mbing s Piping . City of Tukwila RECEIVED CITY OF TUKWILA SEP 2 0 2016 PERMIT CENTER REV # DATE DRAWN CM CHECKED CM DATE 09/16/2016 ONE -LINE RISER DIAGRAM E 5. 0 1 M L L L N N N co M LO \N.. M LO v UZ Z Z O LL _ a U W W W~ W Uj "_I W~ = N N Mp = OLr) 00 rn 'S CO Z Y � REV # DATE DRAWN CM CHECKED CM DATE 09/16/2016 ONE -LINE RISER DIAGRAM E 5. 0 1 NU It: baseo on I HHV Insulation, tM i conoun ana unapier v, !ante 4 and Table' 5a fbr compact AL wire, of the NEC, 2008 edition. - Indicates acceptable overcurrent device rating for single feeder. This rating shall not be used for sizing parallel feeders. i I-- '* In-dicates overcurrent protective dev~ce rating that may be used forthis feeder __, _ _. _ :_ _.._ . _._ . _._ _ __-__ ._.________-- The Contractor shall install feeder size indicated even if Code allows smaller to be used. i GRADE UTILITY DEMAND R#Z017452912 ------ -- .._DEMAND ---- 200.64 i EquipmentAllowances ------ HP E4UIP EQUIP A ---- -- --NEC -- NEC Description I HP V PH KW KW I A KW I QTY DEMAND REFERENCE TOTAL TENANT SPACE __.___._..____. _._ 72.05- KVA ELL1-1 TENANT SPACE FULL LOAD 208 3 200 7205 1 100% PAN ( ) J 0 .0 100 0 05 KVA PANEL LI -2 TENANT SPACE (FULL LOAD) I 208 3 I 20 72 5 f 1 % 72. TOTAL ->422,77 KVA - 56,8.52 A@ ;480V EXTERIOR INTERIOR NEMA 3R NEMA 1 PANEL XFMR vw XFMR vw H1 M o #6G #6G I o 0 i PANEL PANEL L1-1 L1-2 AREA OF WORK 200A 200A 40 MCB MCB I LOAD SIDE FEED TO ' INTERCEPT EXISTING SPARE I I CONDUITS IN BUSS GUTTER I t NEW r_____________L__________, EXISTING SPARE CONDUITS FEEDER SCHEDULE ALUMINUM PSE METER EMT AMPACITYI N co ID NO RACEWAY WIRE COUNT & SIZE OCP SIZE NOTES 03N 314" 4 - #8, 1#8 G. 30/30 60 -deg rating 03 314" 3-#81#8G. 30/30 60 -deg ratio 04N 1" 4 #6, 1#8 G. 40/40 60 -deg rating - 04 1" _ . -- 3 - #6, 1#8 G. _._ -- 40 / 40 -- - - ---- -- 60 -deg rating --_....- .---- - ----- 60 -deg rating 05N 1 1/4" 4 #4, 1#8 G. - #4_, 1#8 G. 55/50 05 1° 55/5060 -deg rating 06N-- _ 1 1/4" _3 - 4 - #3, 1#8 G. -- - 65/60 - ---- 60 -deg rating 06 1 1/4" 3 - #3, 1#8 G. 65/60 60 -deg rating DISC CT Z Y TAP CAN - � #2, 1#6 G. _ - 75/70 60 -deg rating 08N 1 114 4 #1 1#6 G 85180. 85/80 60 -de rattn 60 -deg rating 8 1 914" 3 #1, 1#6 G 120! 100 - 75 deg.rating 10N#1/0, 1#6 G. 10 1 1J2" 3 - #1/0, 1#6 G. 120/100- 75 -deg rating---­ ating4 3PH 4W 4_41M #1/6, 14-4 G. _3-#i/01_1#4G. 120 / 110 75 deg rating 12 1 112' 1201110 75 -deg rating 13N 2" 4 #2/0 1 #4 G. 135/125 75 -deg rating 13 2" 3 - 4-21-6, 1-#4- G. 135 / 125 75 deg rating 15N 2" 4 - #310, 1 #4 G. 155 / 150 75 -deg rating 15 2 3 #310 1 #4 G 155/150 75 -deg rating 18N 2 112" -4----kill 1 ik G. 1801 175 v - 75 -deg rating #410, 1 ig G. 180 /- 175 75 -deg rating 20N 2 1/2" 4-250kcmil, 1 #4 G. 205 / 200 75 -deg rating _ ___._____.-_ 20 ._ 2 112" _. _- __- #4 G__. 3-250kcmil, 1 #4 G. __._._ 205 / 200 -- ---_ ___ _...-_.__-- 75 -deg rating 22N -2 1/2" 4-300kcmil, 1 #2 G.230 J 225 75 -deg rating - 22 2 112" 3-300kcmil, 1 #2 G. - - 230 / 225 75 -deg rating 25N 3" 4-350kcmil, 1 #2 G. 250/250- 75�deg rating 25 2 1/2" 3-350kcmil, 1 #2 G. 250/250 - - 75 -deg rating 27N 3" 4-400kcmil, 1 #2 G. _ 270 / 250 75 deg rating 27 3400kcmil, 1 #2 G. -2-112F 270/250 75 -deg rating 30N _ 3" 4 50okcmil, 1 #2 G. 310/300 75 -deg rating 30 -y- --s -566-cmil, 1 #2 G. 3101300 75 -deg ratio 34N 3112" 4-600kcmil, 1 #1 G. 340--/-300--- 75 degxating 34 3" 3 600kcmil, 1 #1 G. 34-0--/ 300 75 -deg rating 40N (2) 2112" 4-250kcmil, 1_#1 G.4101400 75 -deg rating 1 #1 G.__ __ -4101400 - - 75 -deg rating - 45N 4-300kcmil, 1 #110 G. 4601450 75 deg rating ---------- - - ---. _. - -- --- -- -- - - 3-300kcmil, 1 4-1/0 G. ____4_6_0_ ._.... - ._/4_ / 450- - -- -----_-_ - -- 75 -deg rating 50N -(2} 3" 4-350kcmil, 1 #1/O G. - 500 -/-5--0-0 - - ---75 deg rating -- 50 3-350kcmil, 1 #1/0 G. 500/500 75 -deg rating 4-500kcmil, 1 #210 G. 620/600 75 -deg rating 60 2 3" 3-500kcmil, 1 #2/0 G. 6201600 75 -de ratio 75N ___(3)T 4-350kcmi1, 1 #310 G. 7501750 75 -deg rating 75 {3)21!2" 3-350kcm 1, 1 43/013. 750! 756 754eg rating 80N (3) 3" 4-460kcmil, 1 #3/0 G. 810/800-- 75 deg rating 80 {3) 21/2" 3 400kcmil, 1 #3/0 G. 4-500kcmil, 1_# G. 810 / 800 75 -deg rating 75-deg_rating 90N (3) 3" 930! 900 3-500kcmil, 1#4/0 G. 930 / 900 75 deg rating 100N (3) 21/2" 4-600kcmit, 1 #4/0.13. 1020 / 1000 75-deg_rating (4) 3" mi 1, 1#410 G. -1020 / 1000 -______ 75 deg rating 120N 41500kcmil, 1 #250 G. 1240 / 1200 75 -deg rating 120 (4} $" 3-500kcmil, 1 #250 G _ 1240 ! 1200 75 -deg rating 4500kcmil, 1 #350 G 1550/1500 75 -deg rating 150 (5) 3" 3-500kcmil, 1 #350 G. 1550/1500 75 -deg rating 160N (6) 3" 4-400kcmil, 1 #350 G. 1620/1600 75 -deg rating 160 (6)2 112" 3 40okcmi1, 1 #350 G- 1620/1600 75 -deg rating 20ON (6)2 1/2" 4-600kcmil, 1 #400 G. 75 -deg rating_ _ 200 - 3-600kcmil, 1 #400 G _ _204012000 2040/2000 75 -deg rating NU It: baseo on I HHV Insulation, tM i conoun ana unapier v, !ante 4 and Table' 5a fbr compact AL wire, of the NEC, 2008 edition. - Indicates acceptable overcurrent device rating for single feeder. This rating shall not be used for sizing parallel feeders. i I-- '* In-dicates overcurrent protective dev~ce rating that may be used forthis feeder __, _ _. _ :_ _.._ . _._ . _._ _ __-__ ._.________-- The Contractor shall install feeder size indicated even if Code allows smaller to be used. i GRADE UTILITY DEMAND R#Z017452912 ------ -- .._DEMAND ---- 200.64 i EquipmentAllowances ------ HP E4UIP EQUIP A ---- -- --NEC -- NEC Description I HP V PH KW KW I A KW I QTY DEMAND REFERENCE TOTAL TENANT SPACE __.___._..____. _._ 72.05- KVA ELL1-1 TENANT SPACE FULL LOAD 208 3 200 7205 1 100% PAN ( ) J 0 .0 100 0 05 KVA PANEL LI -2 TENANT SPACE (FULL LOAD) I 208 3 I 20 72 5 f 1 % 72. TOTAL ->422,77 KVA - 56,8.52 A@ ;480V EXTERIOR INTERIOR NEMA 3R NEMA 1 PANEL XFMR vw XFMR vw H1 M o #6G #6G I o 0 i PANEL PANEL L1-1 L1-2 AREA OF WORK 200A 200A 40 MCB MCB I LOAD SIDE FEED TO ' INTERCEPT EXISTING SPARE I I CONDUITS IN BUSS GUTTER I t NEW r_____________L__________, EXISTING SPARE CONDUITS TO unuTr i SPLICE VAULT 2---- - . -LOOPED � swIrcH XFMR VAULT OW TERMINATION (TYP) EXISTING OUTDOOR SWITCH 1200A, 480Y/277V 3PH, 4W NEMA 3R EXISTING SERVICE FEEDERS: (4) 4" PVC -40 (4) 500KCMIL AL (EACH) ONE -LINE RISER DIAGRAM SCALE: NTS GENERAL NOTES: 1. ALL CONDUCTORS ARE #12 AWG CU UNLESS NOTED OTHERWISE. MC FEEDER CAN BE USED WHERE APPROPRIATE AND AT CONTRACTOR'S DISCRETION. MC FEEDER SHALL BE SIZED PER NEC REQUIREMENTS. 2. EQUIPMENT SHOWN BOLD IS NEW. 3. EQUIPMENT SHOWN DASHED IS EXISTING. 4. FIELD VERIFY EXISTING CONDITIONS PRIOR TO CONSTRUCTION. 5. ALL SWITCHBOARDS AND PANELBOARDS SUPPLIED BY A FEEDER SHALL BE MARKED TO INDICATE THE DEVICE OR EQUIPMENT WHERE THE POWER SUPPLY ORIGINATES PER NEC 408.4(B). 6. FEEDERS ARE ALUMINUM WITH THHN/THWN INSULATION. 7. PROVIDE PULL BOXES AS REQUIRED BY THE NEC. 8. SHORT CIRCUIT CURRENTS LESS THAN 10,000 AIC FOR 208V PANELS AND 14,000 AIC FOR 480V PANELS ARE NOT SHOWN. 9. THE ONE -LINE DIAGRAM IS DIAGRAMMATIC AND DOES NOT SHOW THE ACTUAL ROUTING OF RACEWAYS. 10. FOR TWO SECTION PANELS PROVIDE FULL SIZE FEEDER CONNECTIONS FROM SECTION 1 TO SECTION 2. 11. NOT ALL CIRCUIT BREAKERS ARE SHOWN, REFER TO PANEL AND SWITCHBOARD SCHEDULES FOR OTHER LOADS SERVED, AND SPARE CIRCUIT BREAKERS. FILE COPY Permit No. 1V4/ -_ 0 tW Plan raview ap _,roval is subject to errors and omissions. Approval of construction documents does not authorize the violation of any adopted code or ordinance. Receipt of approved Field Copy and conditions is acknowledged: By: Date: _ /Lo �._..� City of Tukwila BUILDING DIVISION - fiEVISIt__NS _. No Changes shill ho made to the scope of "►o, mithout Prior approval of TUJ<Wlia Building Division. NOTE: Revisions will require anew plan submittal and may include additional plan review fees. I :2QUIR--;z0 FOR, Efolvecttanicei D lectricat PGa mbing s Piping . City of Tukwila RECEIVED CITY OF TUKWILA SEP 2 0 2016 PERMIT CENTER M L L L PSE METER N N co M LO \N.. M LO v UZ Z EXISTING BUSS GUTTER 1 Z O LL _ 1200A, 480Y/277V 3PH, 4W j U NEMA 3R W W r----------------� ' SVC "_I W~ NEW N Mp EXISTING = OLr) 00 rn 'S DISC CT Z Y TAP CAN , � ENCLOSURE;1200A,400A I FUSED 480Y/277V (6) 2" CONDUIT 3PH 4W l (4) 3/0 (EACH) , NEMA 3R (1) 3/OG (EACH) I I L___ ___ __ ___J I I I1 r�\� -1� I 40 40 ; L i r� l ¢ ' ; O�5 i O ------------------------------� EXISTING PSE ( I I O i I CD i i CV 1 I UTILITY XFMR I I I I------------"�------------ ; 1 _ > I I< >11< I I I I I 1 TO unuTr i SPLICE VAULT 2---- - . -LOOPED � swIrcH XFMR VAULT OW TERMINATION (TYP) EXISTING OUTDOOR SWITCH 1200A, 480Y/277V 3PH, 4W NEMA 3R EXISTING SERVICE FEEDERS: (4) 4" PVC -40 (4) 500KCMIL AL (EACH) ONE -LINE RISER DIAGRAM SCALE: NTS GENERAL NOTES: 1. ALL CONDUCTORS ARE #12 AWG CU UNLESS NOTED OTHERWISE. MC FEEDER CAN BE USED WHERE APPROPRIATE AND AT CONTRACTOR'S DISCRETION. MC FEEDER SHALL BE SIZED PER NEC REQUIREMENTS. 2. EQUIPMENT SHOWN BOLD IS NEW. 3. EQUIPMENT SHOWN DASHED IS EXISTING. 4. FIELD VERIFY EXISTING CONDITIONS PRIOR TO CONSTRUCTION. 5. ALL SWITCHBOARDS AND PANELBOARDS SUPPLIED BY A FEEDER SHALL BE MARKED TO INDICATE THE DEVICE OR EQUIPMENT WHERE THE POWER SUPPLY ORIGINATES PER NEC 408.4(B). 6. FEEDERS ARE ALUMINUM WITH THHN/THWN INSULATION. 7. PROVIDE PULL BOXES AS REQUIRED BY THE NEC. 8. SHORT CIRCUIT CURRENTS LESS THAN 10,000 AIC FOR 208V PANELS AND 14,000 AIC FOR 480V PANELS ARE NOT SHOWN. 9. THE ONE -LINE DIAGRAM IS DIAGRAMMATIC AND DOES NOT SHOW THE ACTUAL ROUTING OF RACEWAYS. 10. FOR TWO SECTION PANELS PROVIDE FULL SIZE FEEDER CONNECTIONS FROM SECTION 1 TO SECTION 2. 11. NOT ALL CIRCUIT BREAKERS ARE SHOWN, REFER TO PANEL AND SWITCHBOARD SCHEDULES FOR OTHER LOADS SERVED, AND SPARE CIRCUIT BREAKERS. FILE COPY Permit No. 1V4/ -_ 0 tW Plan raview ap _,roval is subject to errors and omissions. Approval of construction documents does not authorize the violation of any adopted code or ordinance. Receipt of approved Field Copy and conditions is acknowledged: By: Date: _ /Lo �._..� City of Tukwila BUILDING DIVISION - fiEVISIt__NS _. No Changes shill ho made to the scope of "►o, mithout Prior approval of TUJ<Wlia Building Division. NOTE: Revisions will require anew plan submittal and may include additional plan review fees. I :2QUIR--;z0 FOR, Efolvecttanicei D lectricat PGa mbing s Piping . City of Tukwila RECEIVED CITY OF TUKWILA SEP 2 0 2016 PERMIT CENTER REV # DATE DRAWN CM CHECKED CM DATE 09/16/2016 ONE -LINE RISER DIAGRAM E 5. 0 1 M L L L N N N co M LO \N.. M LO v UZ Z Z O LL _ a U W W W~ W Uj "_I W~ = N N Mp = OLr) 00 rn 'S CO Z Y � REV # DATE DRAWN CM CHECKED CM DATE 09/16/2016 ONE -LINE RISER DIAGRAM E 5. 0 1