Loading...
HomeMy WebLinkAboutPermit EL16-1064 - INSPIRUS CREDIT UNION - OFFICE EXPANSION AND GARAGE LIGHTINGINSPIRUS CREDIT UNION 5200 SOUTHCENTER BLVD ELl 6=1 064 City of Tukwila • Department of Community Development • 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Inspection Request Line: 206-438-9350 Web site: http://www.TukwilaWA.Rov ELECTRICAL PERMIT Parcel No: 1157200013 Permit Number: EL16-1064 Address: 5200 SOUTHCENTER BLVD Issue Date: 10/12/2017 International Residential Code Edition: Permit Expires On: 4/10/2018 Project Name: INSPIRUS CREDIT UNION 2014 Owner: 2015 Name: INSPIRUS CREDIT UNION 2014 Address: 5200 SOUTHCENTER BLVD, TUKWILA, 2015 WA, 98188 2015 Contact Person: 2015 Name: MATT LAASE Phone: (206) 324-4800 Address: 311 FIRST AVE S, SEATTLE, WA, 98104 Contractor: Name: SUNDANCER ELECTRIC INC Phone: (253) 398-2999 Address: 19309 68 AVE S - SUITE R105, KENT, WA, 98032 License No: SUNDAE1889JW Expiration Date: 4/16/2018 Lender: Name: Address: DESCRIPTION OF WORK: APPROXIMATELY 15,000 SQ FT OFFICE EXPANSION TO FIRST FLOOR, SECOND FLOOR AND PARKING GARAGE. NEW LIGHTING IN PARKING GARAGE AND NEW OFFICE AREA. ELECTRICAL SERVICE REMAINING. NEW BRANCH CIRCUIT PANELS ADDED AND EXISTING MECHANICAL EQUIPMENT REPLACE WITH NEW. Valuation of single family: $0.00 Fees Collected: $4,626.90 Valuation of mf/comm: $250,000.00 Type of Work: ADDITION Electrical Service Provided by: SEATTLE CITY LIGHT Water District: 125 Sewer District: TUKWILA Current Codes adopted by the City of Tukwila: International Building Code Edition: 2015 National Electrical Code: 2014 International Residential Code Edition: 2015 WA Cities Electrical Code: 2014 International Mechanical Code Edition: 2015 WAC 296-466: 2014 Uniform Plumbing Code Edition: 2015 WA State Energy Code: 2015 International Fuel Gas Code: 2015 Permit Center Authorized Signature: 3q Date:10 `-tom I hearby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this development permit and agree to the conditions attached to this permit. Signature: Date: /v / Z b-7 Print Name: This permit shall become null and void if the work is not commenced within 180 days for the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. PERMIT CONDITIONS: 1: 'ELECTRICAL PERMIT CONDITIONS' 2: A copy of the electrical work permit shall be posted or otherwise made readily accessible to the Electrical Inspector at each work site. 3: Approved plans shall be maintained at the construction site and shall be readily available to the Electrical Inspector. 4: All electrical work shall be in accordance with NFPA 70 - NEC, and requirements for electrical installations, Chapter 296-46B WAC. 5: When any portion of the electrical installation is to be hidden from view by permanent placement of parts of the building, such equipment shall not be concealed until it has been inspected and approved by the Electrical Inspector. 6: The issuance of an electrical work permit shall not be construed to be a permit for, or an approval of, any violation of the provisions of the electrical code or other ordinances of the jurisdiction. Permits or related documentation that presumes to grant this authority are therefore not valid. 7: Any change in the scope of work described by the electrical work permit shall require additional work permits. Where approved plans have been issued, revisions to the plans and additional review may be required. PERMIT INSPECTIONS REQUIRED Permit Inspection Line: (206) 438-9350 2100 ELECTRICAL FINAL 7003 ROUGH -IN ELECTRICAL 7002 SERVICE 7001 UNDERGROUND/SLAB IF t. CITY OF TUKWW, Community Development Department Permit Center • 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 hU://www.TAdmdlaWA.gov Electrical Permit No. L W Project No. Date Application Accepted: Date Application Expires: use ELECTRICAL PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. "Please Print" SITE LOCATION King Co Assessor's Tax No... 115720W13 Site Address: 5200 Southcenter Blvd. Suite Number: Floor: Tenant Name: Inspirus Credit Union New Tenant: ❑ .....Yes O..No PROPERTY OWNER Name: Inspirus Credit Union Address: 5200 Southcenter Blvd City: Tukwila State: WA Zip: 98188 CONTACT PERSON — person receiving all project communication Name: Carol Cameron Address: 5200 Southcenter Blvd. City: Tukwila State: wA Zip: 98188 Phone: (206) 628-4088 Fax: Email: carol@inspiruscu.org ELECTRICAL CONTRACTOR INFORMATION Company Name: TBD Address: City: State: Zip: Phone: Fax: Contr Reg No.: Exp Date: Tukwila Business License No.; Valuation of Project (contractor's bid price): $ 250,000 Scope of Work (please provide detailed information): Approx. 15,000 sgft of office expansion to 1 st floor, 2nd floor and parking garage. New lighting in parking garage and new office area. Electrical service remaining. New branch circuit panels added and existing mechanical equipment replaced with new. Will service be altered? ❑ Yes Type of Use: Office m No Adding more than 50 amps? 0 Yes ❑ No Type of work: ❑ New 0 Addition ❑ Service Change ❑ Remodel 0 Tenant Improvement ❑ Low Voltage ❑ Generator Property Served by: ❑ Fire Alarm ❑ Telecommunication ❑ Temporary Service ❑ Puget Sound Energy 0 Seattle City Light H:Wpplications\Forms-Applications On L ne\2014 ApplicationsElectrical Permit Application Revised 1-1-14.doex Revised: January 2014 bb Page 1 of 2 PF - RESIDENTIAL NEW RESIDENTIAL SERVICE ❑ New single family dwellings ................................... $152.85 (including an attached garage) ❑ Garages, pools, spas and outbuildings ........................$81.90 ea ❑ Low voltage systems (alarm, furnace thermostat) ................................ $59.85 ea RESIDENTIAL REMODEL AND SERVICE CHANGES ❑ Service change or alteration ...................................... $81.90 (no added/altered circuits) ❑ Service change with added/altered circuits ................. $81.90 number of added circuits ....................... $11.55 ea ❑ Circuits added/altered without service change ........... $54.60 (up to 5 circuits) ❑ Circuits added/altered without service change ........... $54.60 (6 or more circuits) ............................................... $7.65 ea ❑ Meter/mast repair ....................................................... $68.25 ❑ Low voltage systems ................................................. $59.85 (alarm, furnace thermostat) PERMIT APPLICATION NOTES - MULTI -FAMILY AND COMMERCIAL Fees are based on the valuation of the electrical contract. MISCELLANEOUS FEES ❑ Temporary service (residential) ................................. $65.00 ❑ Temporary service (generator) ................................... $80.90 ❑ Manufactured/mobile home service ........................... $86.25 (excluding garage or outbuilding) ❑ Carnivals.................................................................... $80.60 Number of concessions ......................... $10.80 ea Each ride and generator truck ............... $10.80 ea ***EFFECTIVE JANUARY 1, 2014 EACH PERMIT WILL BE ASSESSED A 5% TECHNOLOGY FEE*** Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The Building Official may grant one extension of time for an additional period not to exceed 90 days. The extension shall be requested in writing and justifiable cause demonstrated. I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER OR ELECTRICAL CONTRACTOR: Signature: Date: It. -A— 9.0 C, Print Name: WIC -1006A5 K Day Telephone:1A JA ,, `` Mailing Address: �� 1T15� �y�lU1�f-- 50U`rl{ S�/4TfL�yVA `19%67 City slate zip H:Wpplicationc\Fonis-Applications On Line\2014 APplicationsTleetrieal Permit Application Revised 1-1-14.docx Revised: January 2014 bh Page 2 of 2 DESCRIPTIONS • QUANTITY PAID PermitTRAK $315.18 EL16-1064 Address: 5200 SOUTHCENTER BLVD Apn: 1157200013 $315.18 Credit Card Fee $9.18 Credit Card Fee R000.369.908.00.00 0.00 $9.18 DEVELOPMENT $306.00 PERMIT REINSPECT FEE - AFTER HRS INSP R000.359.000.00.01 0.00 $306.00 FEE TOTAL:1. Date Paid: Tuesday, June 26, 2018 Paid By: JAY HORTON Pay Method: CREDIT CARD 416262 Printed: Tuesday, June 26, 2018 12:26 PM 1 of 1 CRSYS7EM5 Page 1 of 2 CO TUKWILA ETRAKIT 6200 SOUTHCENTER BLVD TUKWILA, WA 98188 206-433-1870 CITY OF TUKWILA 0017340000802374464500 Date: 06/26/2018 12:26:34 PM CREDIT CARD SALE VISA CARD NUMBER: **********6454 K TRAN AMOUNT: $315.18 APPROVAL CD: 416262 RECORD #: 000 CLERK ID: Rachelle X (CARDHOLDER'S SIGNATURE) I AGREE TO PAY THE ABOVE TOTAL AMOUNT ACCORDING TO THE CARD ISSUER AGREEMENT (MERCHANT AGREEMENT IF CREDIT VOUCHER) Thank you! Merchant Copy https: //classic. convergepay. comNirtualMerchantltransaction. do?dispatchMethod=printTra... 6/26/2018 Page 2 of 2 CO TUKWILA ETRAKIT 6200 SOUTHCENTER BLVD TUKWILA, WA 98188 206-433-1870 CITY OF TUKWILA Date: 06/26/2018 12:26:34 PM CREDIT CARD SALE VISA CARD NUMBER: **********6454 K TRAN AMOUNT: $315.18 APPROVAL CD: 416262 RECORD #: 000 CLERK ID: Rachelle Thank you! Customer Copy https:Hclassic. convergepay. comNirtualMerchantltransacti on. do?dispatchMethod=printTra... 6/26/2018 DESCRIPTIONS ACCOUNTQUANTITY PAID PermitTRAK $3,737.11 EL16-1064 Address: 5200 SOUTHCENTER BLVD Apn: 1157200013 $3,737.11 ELECTRICAL $3,559.15 PERMIT FEE MULTI-FAM/COMM R000.322.101.00.00 0.00 $3,559.15 TECHNOLOGY FEE $177.96 TECHNOLOGY FEE TOTAL FEES PAID BY RECEIPT: R12557 R000.322.900.04.00 0.00 $177.96 $3,737.11 Date Paid: Thursday, October 12, 2017 Paid By: SUNDANCER ELECTRIC INC Pay Method: CHECK 8695 Printed: Thursday, October 12, 2017 11:52 AM 1 of 1 C SY57EM5 DESCRIPTIONS PermitTRAK ACCOUNT QUANTITY PAID $12,486.57 D16-0317 Address: 5200 SOUTHCENTER BLVD Apn: 1157200013 $8,255.43 DEVELOPMENT $8,005.43 PLAN CHECK FEE R000.345.830.00.00 0.00 $8,005.43 PUBLIC WORKS $250.00 BASE APPLICATION FEE R000.322.100.00.00 0.00 $250.00 D16-0318 Address: 5200 SOUTHCENTER BLVD Apn: 1157200013 $1,535.04 DEVELOPMENT $1,535.04 PLAN CHECK FEE R000.345.830.00.00 0.00 $1,535.04 EL16-1064 Address: 5200 SOUTHCENTER BLVD Apn: 1157200013 $889.79 ELECTRICAL $889.79 PLAN CHECK FEE R000.345.832.00.00 0.00 $889.79 M16-0176 Address: 5200 SOUTHCENTER BLVD Apn: 1157200013 $1,697.93 MECHANICAL $1,697.93 PLAN CHECK FEE R000.322.102.00.00 0.00 $1,697.93 PG16-0169 Address: 5200 SOUTHCENTER BLVD Apn: 1157200013 $108.38 PLUMBING $108.38 PLAN CHECK FEE TOTAL FEES PAID BY RECEIPT: ....4 R000.322.103.00.00 0.00 $108.38 $12,486.57 Date Paid: Monday, November 21, 2016 Paid By: INSPIRUS CREDIT UNION Pay Method: CHECK 0002215980 Printed: Monday, November 21, 2016 2:08 PM 1 of 1 . SYSTEMS % INSPECTION RECORD n ` Retain a copy with permit U INSPECTION N0, ERMIT N0. CITY OF TUKWILA BUILDING DIVISION ` 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-36 0 Permit Inspection Request Line (206) 438-9350 Project: /Z)P1IWi Type of Inspection: Address: Date Called: Special Instructions: Date Wanted: a. Requester: T Phone No: 3 S2 961Approved per applicable codes. El Corrections required prior to approval. !Inspector: Chzm40 1uate: Og/ )/1 I REINSPECTION FEE REQUIRED. Prior to next inspection, fee'must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. INSPECTION RECORD l � r l Retain a copy with permit INSPECTION NO. PERMIT N0. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3 Permit Inspection Request Line (206) 438-9350 Project: Type of Inspection: Address: Date Called: Special Instructions: Date Wanted: a.m. p.m. Requester�K( #— Phone No: �p 5aApproved per applicable codes. LJ Corrections required prior to approval. IInspector: �/1 IDate: 0 g Jr3 //z ❑ REINSPECTION tFEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. �+�✓ INSPECTION RECORD r/ U Retain a copy with permit INSPECTION N0, PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila: WA 98188 (206) 431-367 Permit Inspectio Request Line (206) 438-9350 Project: C Type of Inspection: Address: yy LO.oS . %y T Date Called: Special Instructions: Date Wanted: .m. Lo p.m Requester: Phone No: DApproved per applicable codes. E Corrections required prior to approval. U paid at 6300 Southcenter Blvd., Suite 100. Gall to schedule reinspection. INSPECTION RECORD t f f Retain a copy with permit INSPE ION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-36 Permit Inspection Request Line (206) 438-9350 4 Project:/� � 1(� r Type of inspection: Address: C Date Called: Special Instructions: Date Wanted: a.m P.M. Requester: Phone No: Approved per applicable codes. LJ Corrections required prior to approval. Date: REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call. to schedule reinspection. INSPECTION RECORD Retain a copy with permit INSPECTION NO. PEIMITN0. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Project: 1 f„ r Type of Inspection: II vv Address: Date Called: Special Instructions: Date Wanted: M. 11-0 Requester: Phone No: 371 7M, nApproved per applicable codes. LJ Corrections required prior to approval. '—' paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. INSPECTION RECORD �p f Retain a copy with permit (j INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila: WA 98188 (206) 431-367 Permit Inspection Request Line (206) 438-9350 Project: LA N0 Type of Inspection: 0/1 Address: ��++ -&- 9L Date Called: Special I structions: Date Wanted: a.m p.m. Requester: Phone No: 10— 7 Approved per applicable codes. 1-1 Corrections required prior to approval. I I paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT N0. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd.., #100, Tukwila. WA 98188 (206) 431-367 Permit Inspection Request Line (206) 438-9350 Project: Type of Inspection: r Address: �,t ^ � � � r Date Called: Special Instructions: Date Wanted: , a.m' Requester: Phone No: ;7 V17716 Approved per applicable codes. E Corrections required prior to approval. COMMENTS: inspector: , - / Date: �� ®L / ' I REINSPECTION'FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. INSPECTION RECORD (14, / qjRetain a copy with permit `�Ou INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-36 Permit Inspection Request Line (206) 438-9350 Project: - rC Type of Inspection: r Address- ./� � L-- Date Called: Speciil Instructions: Date Wanted: r a.m .m. Requester: Phone No:+� ' 47 `/,l7� - nApproved per applicable codes. LJ Corrections required prior to approval. u paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. INSPECTION RECORD Retain a copy with permit[ INSPECTION NO. PERMIT N0. CITY OF" TUKWILA BUILDING DIVISION 6300 Southcenter Blvd.., #100, Tukwila. WA 98188 (206) 431 - Permit Insnectian Reauest Line (206) 438-9350 ❑ Approved per applicable codes. 1:1 Corrections required prior to approval. lJ paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. —] INSPECTION RECORD j I Retain a copy with permit s!� INSPECTION NO. PERMIT N0. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd- #100, Tukwila. WA 98188 (206) 431-367 Permit Inspection Request Line (206) 438-9350 Project: Type of Inspection: L l Al Address: C J .VZO�J . c b —1 Date Called: Special Instructions: 7 t- '�Vj � �` ��5 Date Wanted: a. Requester: Phone No: Al 321 7Z 26 Approved per applicable codes. LJ Corrections required prior to approval. 4y Ir I -.-- Inspector: ( //� IDate: F] REINSPECTION IEEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. INSPECTION RECORD Retain a copy with permit INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431 - Permit Inspection Request Line (206) 438-9350 Project: (� %�`� �1 f & > Type of Inspection: p f LO�id ` Address: Date Called: Special Instructions: Date Wanted: a ' Requester: Phone No: Approved per applicable codes. E Corrections required prior to approval. COMMENTS: l(" Woo i (Inspector: l rllwr j6 1Date: o �11(" II3 REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. INSPECTION RECORD ,,/ Retain a copy with permit �411 I001 I N S P E MlON N0, ­7MMIT N0. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd.., #100, Tukwila. WA 98188 (206) 431-367 Permit Inspection Request Line (206) 438-9350 -17 Project: Type of Inspection: Y lk fAl Address: < ,^ �!�%C% �.J • lam- Date Called: Special Instructions: Date Wanted: a.m. .m. Requester: Phone No: Approved per applicable codes. Corrections required prior to approval. L _1 paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. INSPECTION RECORD y� Retain a copy with permit 1 INSPE ION N0. ERMIT N . CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-367 Permit Inspection Request Line (206) 438-9350 Project: j Type of Inspection: Address: Date Called: Special Instructions: #236 Date Wanted: a.m ) p.m. Requester: Phone No: Approved per applicable codes. 1:1 Corrections required prior to approval. /57- I Inspector: /f� N"/CK— IDate: o3/3R/rb REINSPECTIONJFEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. INSPECTION RECORD Retain a copy with permit �I INSPECTION NO. PERMIT N0. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-36ji Permit Inspection Request Line (206) 438-9350 Proiect: i _ _ A _ i " ITyjA of In6pection: (Address: � , // - (Date Called: / Inst o: zl— til Approved per applicable codes. E Corrections required prior to approval. v Inspector:�.//`e� (Date: 0�/��/r I F] REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Z INSPECTION RECORD , f�/ Retain a copy with permit f� INSPECTION N0. RMIT NQ. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-367 Permit Inspection Request Line (206) 438-9350 Project:Z ' 1 V Al -Vpe of Inspection: / Address: 5 0 9L= Date Called: ` Special Instructions: Date Wanted: a. p.m. Requester: Phone No: ❑ Approved per applicable codes. LJ Corrections required prior to approval. IJ paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. j INSPECTION RECORDRN Retain a copy with permitINSPECTION NO. PERMIT CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-367 Permit Inspection Request Line (206) 438-9350 4 Project: �L5 P1 W-5Type of Inspection: Address: Date Called: Special Instructions: Date Wanted: ® p.m. Requester:tht Phone No: Approved per applicable codes. LJ Corrections required prior to approval. I rlL, \, - z, fi�-oti sj,'rr -u pector: 0 REINSPECTIf N FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. OFF HOURS INSPECTION c Reimbursement authorization/approval to conduct inspection activities during off hours. Date: � 1 U., f 1 Requested By: , -(___"'D , ()rJ Firm/Company: SJ030Ar-1CPa- Nle CTR%C 1-r4 C , Inspection Information Permit Number: � �A � m U + Project Name: P12uS Ote0►T 0r-3ior Project Address/Location: 5260 5 o w rH U h -rt ,ti BL -J p Requested Date for Inspection: �jp I Requested Time:_-( 0', 3C> ql /PM Contact Name: �Ay,' 6C-VV\p,,. C Phone Number:265 -39Z- x17c?4 Special Conditions for Consideration: 5e4w%Lc flA->ge C --S I C> N) F-ple fAeae- ADD, -v\,,,,35 ** Contractor will be charged a minimum for three (3) hour inspection time for any off -hours inspection work at $102.00 per hour (minimum total of $306.00). This is to be paid at the time of request. ** The undersigned, as an authorized representative of the above firm, hereby agrees to reimburse the City for its overtime inspections on the above referenced project. A separate invoice will be issued for all inspection time in excess of three (3) hours. Signature:n::�:J V J-- Date:/2� /i Printed Name: �"/}y I-I00-T0rJ SJA0a,-ic.ea- F-l¢C-7VZ' L -C.Jc, City Use Only Approved: Disapproved: Date of Approval/Disapproval: Authorized Reviewer: W:\Permit Center\Applications-Handouts\Templates\Forms\Off Hours Inspection 1-2017.docx Revised: January 1, 2017 AM W Remarks: Receipt No:P-14Ma Citv of Tukwila Department of Community Development - Jack Pace, Director May 17, 2017 Matt Laase Jackson/Main Architecture 311 First Ave S Seattle, WA 98104 RE: Request for Application Extension #1 Permit Number EL16-1064 Dear Mr. Laase, Allan Ekberg, Mayor This letter is in response to your written request for an extension to Application Number ELI 6-1064. The Building Official, Jerry Hight, has reviewed your letter and considered your request to extend the above referenced permit. It has been determined that the City of Tukwila Building Division will be granting an extension to the permit through November 21, 2017. If you should have any questions, please contact our office at (206) 431-3670. Sincerely, Bill Rambo Permit Technician File: Permit No. ELI 6-1064 Tukwila City Hall • 6200 Southcenter Boulevard • Tukwila, WA 98188 • 206-433-1800 • Website: TukwilaWA.gov Bill Rambo From: Matt Laase <Matt.Laase@jacksonmain.com> Sent: Friday, May 12, 2017 9:01 AM To: Bill Rambo Cc: Lindsay Brown; Carol Cameron (Carol@inspiruscu.org) Subject: Inspirus Permit Applications Extension Request Dear Bill, We respectfully request an extension on picking up the permits listed below as we are awaiting final reviews and corrections on our building permit application (D16-0317) and the client is in the process of contracting with a general contractor who will be picking up the permits. The permits in need of a 90 day extension are: PG16-0169 EL16-1064 M16-0176 Please let me know if you need any additional information. All 3 permits listed above are due to expire on 5/21/2017. Thanks, Matt Matthew L.aase AIA 5 pw Principal JACKSON I MAIN Architecture, P.S. 311 First Avenue South Seattle, Washington 98104 206.324.4800 P 1206.465.4452 M www.eacksonmain.com f Request for Extension. # I Current Expiration Date: ^,` 17 Extension Request: yApproved for days �--� ❑ Denied (provide explanation) Signature/initials RECEIVED CITY OF TUKWILA MAY 12 2017 1 PERMIT CENTER 4/3/2017 City of Tukwila Allan Ekberg, Mayor Department of Community Development Jack Pace, Director MATT LAASE 311 FIRST AVE S SEATTLE, WA 98104 RE: Permit Application No. ELI 6-1064 INSPIRUS CREDIT UNION 5200 SOUTHCENTER BLVD Dear MATT LAASE, In reviewing our current application files, it appears that your permit applied for on 11/21/2016, has not been issued by the City of Tukwila Permit Center. Per the International Building Code, International Mechanical Code, Uniform Plumbing Code and/or National Electrical Code every permit application not issued within 180 days from the date of application shall expire and become null and void. Currently your application has a status of APPROVED and is due to expire on 5/21/2017. If you still plan to pursue your project, you are hereby advised to do one of the following 1) If the plan review is complete for the project and your application is approved, you may pick up the application before the date of expiration. At the time of permit issuance the expiration date will automatically be extended 180 days. QeTe 2) If the plan review is not completed submit a written request for application extension (7) seven days in advance of the expiration date. Address your extension request to the Building Official and state your reason(s) for the need to extend your application. The Building Code does allow the Building Official to approve one extension of up to 90 days. If it is determined that your extension request is granted, you will be notified by mail. In the event that we do not receive your written request for extension or request is denied, your permit application will expire and your project will require a new permit application, plans and specifications, and associated fees. Thank you for your cooperation in this matter. Sincerely, RachWeipley Permit Technician File No: ELI 6-1064 6300 Southcenter Boulevard Suite #100 9 Tukwila Washington 98188 0 Phone 206-431-3670 • Fax 206-431-3665 PERMIT COORD COH PLAN REVIEW/ROUTING SLIP PERMIT NUMBER: ELI 6-1064 DATE: 11/21/16 PROJECT NAME: INSPIRUS CREDIT UNION SITE ADDRESS: 5200 SOUTHCENTER BLVD X Original Plan Submittal Revision # before Permit Issued Response to Correction Letter # Revision # after Permit Issued DEPARTMENTS: �t kvA Building Division Fire Prevention ❑ Planning Division ❑ Public Works ❑ Structural ❑ Permit Coordinator PRELIMINARY REVIEW: DATE: 11/22/16 Not Applicable ❑ Structural Review Required ❑ (no approval/review required) REVIEWER'S INITIALS: APPROVALS OR CORRECTIONS: DATE: DUE DATE: 12/20/16 Approved ❑ Approved with Conditions ❑ Corrections Required ❑ Denied ❑ (corrections entered in Reviews) (ie: Zoning Issues) Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: iznsrzou Sundancer Electric Inc inWashington State Department of Labor Industries Sundancer Electric Inc Owner or tradesperson Principals DESJARLAIS, GRINELLE E, PRESIDENT DESJARLAIS, GRINELLE, AGENT Doing business as Sundancer Electric Inc WA UBI No. 603 190 024 License Horne Espar'iol Contact Safety & Health Claims & Insurance 19309 68th Ave S Ste R105 KENT, WA 98032 253-398-2999 KING County Business type Corporation Page 1 of 3 Search L&I A -Z Index Workplace Rights Verify the contractor's active registration / license / certification (depending on trade) and any past violations. Electrical Contractor Active. ............................................................... Meets current requirements. License specialties GENERAL License no. SUNDAE1889JW Effective — expiration 04/16/2012— 04/16/2018 Designated administrator DESJARLAIS, GRINE11 LLE E License type Master Electrician Bond ............-- Berkley Insurance Co Bond account no. 0205669 Active. Meets current requirements. License no. DESJAGE976NK $4,000.00 Help us improve https://secure,Ini.wa.gov/verify/Detail.aspx?UBI=603190024&LIC=SUNDAEI889JW&SAW= 10/12/2017 Sundancer Electric Inc Received by L&I 04/03/2017 Bond history Savings ..................... No savings accounts during the previous 6 year period. License Violations ........................................................ Infraction no. EHOGG00395 Issue date 02/19/2013 Violation city Kent Type of violation ELECTRICAL CITATION Description Failing to request an inspection within 3 business days after completion of the installation or 1 business day after energizing, whichever occurs first as referenced in WAC 29646B -900(10)(a), effective after 12/30/2008 see WAC 296-466-901(10)(a). Workers' comp Effective date 04/09/2017 Expiration date Until Canceled Satisfied ................1.......... RCW/WAC 19.28.101 RCW Violation amount $250.00 Do you know if the business has employees? If so, verify the business is up-to-date on workers' comp premiums. This company has multiple workers' comp accounts. Active accounts ......................................1.......... L&I Account ID Account is current. 975,693-02 Doing business as SUNDANCER ELECTRIC INC Estimated workers reported Quarter 2 of Year 2017 "31 to 50 Workers" L&I account contact T1 / FEARAED FEROZE (360)902-4797 - Email: FERH235@lni.wa.gov Track this contractor Public Works Strikes and Debarments Page 2 of 3 Verify the contractor is eligible to perform work on public works projects. Contractor Strikes ........................................................ No strikes have been issued against this contractor. Contractors not allowed to bid No debarments have been issued against this contractor. Help us improve https:Hsecure.lni.wa.gov/verify/Detail.aspx?UBI=603190024&LIC=SUNDAEI889JW&SAW= 10/12/2017 DIVISION 16 - ELECTRICAL WORK 16000.0 GENERAL ELECTRICAL CONDITIONS .1 CONFORM TO THE GENERAL CONDITIONS, SUPPLEMENTARY CONDITIONS AND RELATED WORK IN OTHER DIVISIONS FOR ALL WORK IN DIVISION 16. SEE DIVISION 1 FOR SEQUENCE OF WORK. .2 WORK INCLUDED: IT IS THE INTENT OF THIS DIVISION OF THE SPECIFICATIONS AND ACCOMPANYING DRAWINGS TO DESCRIBE AND PROVIDE FOR THE FURNISHINGS, INSTALLING, TESTING AND PLACING IN SATISFACTORY AND SUCCESSFUL OPERATION ALL EQUIPMENT, MATERIALS, DEVICES AND NECESSARY APPURTENANCES TO PROVIDE A COMPLETE ELECTRICAL SYSTEM, TOGETHER WITH SUCH OTHER MISCELLANEOUS INSTALLATIONS AND EQUIPMENT HEREINAFTER SPECIFIED AND/OR SHOWN IN THE PLANS. THE WORK SHALL INCLUDE ALL MATERIALS, APPLIANCES AND APPARATUS NOT SPECIFICALLY MENTIONED HEREIN OR NOTED ON THE PLANS, BUT WHICH ARE NECESSARY TO MAKE A COMPLETE WORKING INSTALLATION OF ALL ELECTRICAL SYSTEMS SHOWN ON THE PLANS OR DESCRIBED HEREIN. EQUIPMENT AND DEVICES FURNISHED AND INSTALLED UNDER OTHER DIVISIONS OF THIS SPECIFICATION (OR BY THE OWNER) SHALL BE COLLECTED UNDER THIS DIVISION. THE DRAWINGS AND SPECIFICATIONS ARE COMPLIMENTARY AND WHAT IS CALLED FOR IN EITHER IS BINDING AS IF CALLED FOR IN BOTH. BY SUBMITTING A BID THE CONTRACTOR IS ACKNOWLEDGING THAT HE/SHE HAS MADE A THOROUGH EXAMINATION OF THE CONTRACT DOCUMENTS, EXISTING SITE AND BUILDING CONDITIONS, AND HAS DETERMINED THAT THESE DOCUMENTS DO SUFFICIENTLY DESCRIBE THE SCOPE OF CONSTRUCTION WORK REQUIRED UNDER THIS CONTRACT. .3 SCOPE OF BASIC BID: INCLUDED IN DIVISION 16 IS ALL WORK AND RELATED ITEMS NECESSARY TO PROVIDE ALL ELECTRICAL INSTALLATIONS EXCEPT AS SPECIFICALLY EXCLUDED. IN GENERAL, THIS INCLUDES ALL LABOR, EQUIPMENT, TOOLS, SUB -CONTRACTORS (SKILLED TRADES, LICENSES, PERMITS, PROGRAMMERS, ETC), REQUIRED TO COMPLETE THE ELECTRICAL WORK. .4 DEFINITIONS: A. PROVIDE SHALL BE INTERPRETED AS TO FURNISH AND INSTALL. B. FURNISH SHALL BE INTERPRETED AS TO PURCHASE AND DELIVER TO THE SITE READY FOR INSTALLATION, PROTECTED FROM THE ELEMENTS AND FROM VANDALISM AND THEFT. C. INSTALL SHALL BE INTERPRETED AS TO MAKE READY FOR USE AND TO MAKE COMPLETE AND OPERATIONAL. .5 PROTECTION L STORE AND GU THE CONTRACTOR SHAL ARD ALL EQUIPMENT BEFORE INSTALLATION AND SHALL PROTECT SAME AND SHALL REPLACE ANY EQUIPMENT THAT HAS BEEN DAMAGED PRIOR TO FINAL ACCEPTANCE. 16010.0 GENERAL PROVISIONS: PROVIDE COMPLETE AND FULLY OPERATIONAL ALL ELECTRICAL SYSTEMS SPECIFIED AND/OR SHOWN ON THE PLANS, ALONG WITH POWER CONNECTIONS TO EQUIPMENT FURNISHED UNDER OTHER DIVISIONS OF THE SPECIFICATIONS. .1 CODES: CONFORM AND COMPLY WITH THE FOLLOWING CODES AND STANDARDS AS PRESENTLY APPLICABLE: D. 2014 NATIONAL ELECTRICAL CODE E. 2012 WASHINGTON STATE ENERGY CODE F. 2012 SEATTLE ENERGY CODE G. NFPA 72 H. ANSI/BICSI/TIA/EIT CABLING & COMMUNICATIONS STANDARDS. I. ALL STATE AND LOCAL CODES, ORDINANCES AND REGULATIONS .2 PERMITS AND FEES: OBTAIN AND PAY FOR ALL REQUIRED LICENSES, PERMITS AND INSPECTIONS. THE CONTRACTOR SHALL OBTAIN AND PAY FOR ALL LICENSES, PERMITS AND INSPECTIONS REQUIRED BY LAWS, ORDINANCES AND RULES GOVERNING WORK SPECIFIED HEREIN. THE CONTRACTOR SHALL ARRANGE FOR INSPECTION OF THE WORK BY THE INSPECTORS AND SHALL GIVE THE INSPECTORS ALL NECESSARY ASSISTANCE IN THEIR WORK OF INSPECTION. THE CONTRACTOR SHALL CONSULT WITH AND FOLLOW THE REQUIREMENTS OF THE LOCAL FIRE, POWER, TELEPHONE/DATA AND TELEVISION UTILITIES SERVING THE AREA AND SHALL COORDINATE HIS WORK WITH THEM. UTILITY CONNECTION AND HOOK-UP CHARGES FOR POWER, TELEPHONE/DATA AND TELEVISION SHALL BE PAID BY THE OWNER DIRECTLY TO THE UTILITY. THE ELECTRICAL CONTRACTOR IS REQUIRED TO PROVIDE ANY AND ALL COORDINATION NECESSARY TO SUPPORT THE UTILITY CONNECTION, FILE FOR APPLICATION OF SERVICE (OR ASSIST THE OWNER IN FILING FOR APPLICATION OF SERVICE) AND COORDINATE DATES FOR SERVICE WITH THE UTILITIES. .3 MATERIALS: SHALL BE NEW AND EACH TYPE OF MATERIAL FURNISHED SHALL BE OF THE SAME MAKE AND SHALL BE THE STANDARD PRODUCTS OF MANUFACTURERS, REGULARLY ENGAGED IN THE PRODUCTION OF SUCH MATERIALS AND SHALL BE THE MANUFACTURER'S LATEST STANDARD DESIGN. ALL MATERIALS AND EQUIPMENT INSTALLED, INCLUDING LIGHT FIXTURES SHALL HAVE BEEN TESTED AND LISTED BY UNDERWRITERS LABORATORIES OR OTHER NATIONALLY RECOGNIZED TESTING LABORATORY AND SHALL BE SO LABELED IN ACCORDANCE WITH OSHPD CODE APPLICATION NOTICE 3-110-2. .4 WARRANTY. PROVIDE A WRITTEN WARRANTY THAT THE DIVISION 16 WORK IS FREE FROM MECHANICAL AND ELECTRICAL DEFECTS. CONTRACTOR SHALL REPLACE AND PAIR SATISFACTION ENGINEER, RT RE T THE SA TION OF THE ANY PA OF THE I STALLA11ON WHICH MAY FAIL WITHIN A� PERIOD OF TWELVE MONTHS AFTER THE CERTIFICATE OF FINAL ACCEPTANCE. .5 CONTRACT DRAWINGS: THE ELECTRICAL DRAWINGS ARE INTENDED TO SERVE AS WORKING DRAWINGS FOR GENERAL LAYOUT. THE EQUIPMENT LAYOUT IS DIAGRAMMATIC AND UNLESS SPECIFICALLY DIMENSIONED OR DETAILED, DOES NOT INDICATE ALL FITTINGS, HARDWARE OR APPURTENANCES REQUIRED FOR A COMPLETE OPERATING INSTALLATION. ANYTHING SHOWN ON THE DRAWINGS BUT NOT COVERED IN THE SPECIFICATIONS, OR ANYTHING SHOW IN THE SPECIFICATIONS BUT NOT COVERED ON THE DRAWINGS SHALL BE AS IF COVERED AND SHOWN IN BOTH. IN CASE OF CONFLICT BETWEEN THE DRAWINGS AND SPECIFICATIONS, THE ENGINEER SHALL SELECT THE METHOD/PRODUCT AND INSTALLATION THEREOF. THE CONTRACTOR SHALL BE RESPONSIBLE FOR VERIFYING ALL MEASUREMENTS BEFORE PROCEEDING WITH THE WORK. WIRING DIAGRAMS ARE NOT INTENDED TO INDICATE THE EXACT COURSE OF RACEWAYS OR EXACT LOCATION OF EQUIPMENT. RACEWAY AND OUTLET/DEVICE LOCATIONS ARE APPROXIMATELY CORRECT AND ARE SUBJECT TO REVISION AS MAY BE NECESSARY OR DESIRABLE AT THE TIME OF INSTALLATION. PRECISE LOCATION IN EVERY CASE SHALL BE SUBJECT TO THE ENGINEER'S APPROVAL. .6 RECORD DRAWINGS: ONE (1) FULL PRINT SET AT THE JOB SITE, KEPT CONTINUALLY UPPDATED. SUBMIT TO ARCHITECT AT COMPLETION OF PROJECT. .7 MAINTENANCE MANUALS: COMPLETE FOR EVERY SYSTEM. HARDBOARD COVERS WITH 3 RING BINDERS. 2 Ia L0 N 0 N O .z•. ELECTRICAL SPECIFICATIONS 16050.0 EXISTING SYSTEMS .1 EXISTING SYSTEMS MAINTAINED: MAINTAIN EXISTING SYSTEMS IN OPERATION DURING CONSTRUCTION. VISIT THE SITE PRIOR TO BID TO VERIFY EXISTING CONDITIONS, DEMOLITION WORK AND NEW WORK REQUIRED. ANY EXISTING WIRING SERVING DEVICES TO REMAIN IN SERVICE AND WHICH IS INTERRUPTED BY WORK PERFORMED UNDER THIS CONTRACT SHALL BE REROUTED TO MAINTAIN CIRCUIT CONTINUITY. INCLUDE ALL COSTS IN BID. .2 EXISTING SYSTEMS CONCEALED: THE ELECTRICAL DRAWINGS SHOW PORTIONS OF THE EXISTING ELECTRICAL SYSTEMS WHICH ARE TO REMAIN, BE REMOVED OR BE MODIFIED AS A PART OF THE CONTRACTOR'S WORK. CONCEALED FEATURES OF THE EXISTING SYSTEMS ARE DERIVED FROM RECORD DRAWINGS AND THE ENGINEER'S BEST JUDGMENT OF THE CONFIGURATION, BUT NO GUARANTEE IS MADE AS TO THEIR CORRECTNESS. THE CONTRACTOR SHALL INSPECT THE EXISTING INSTALLATION PRIOR TO BIDDING AND SHALL MAKE HIS OWN JUDGMENT AS TO THE WORK REQUIRED TO PROVIDE A COMPLETE INSTALLATION AND DEMOLITION WITHIN THE INTENT OF THE CONTRACT DOCUMENTS. .3 EXISTING CIRCUITS: THE DRAWINGS SHOW PORTIONS OF THE EXISTING ELECTRICAL SYSTEM DERIVED FROM THE EXISTING RECORD DRAWINGS WHICH ARE INCOMPLETE AND NO GUARANTEE IS MADE TO THEIR CORRECTNESS. PRIOR TO THE START OF CONSTRUCTION THE CONTRACTOR SHALL PERFORM A CIRCUIT VERIFICATION TEST OF THE EXISTING RECEPTACLES SHOWN ON THE ELECTRICAL DRAWINGS UTILIZING A CIRCUIT TRACER. THIS INFORMATION SHALL BE MARKED UP ON A COPY OF THE CONTRACT DRAWINGS AND FORWARDED TO THE ENGINEER SO THAT THE CONTRACT DRAWINGS CAN BE CORRECTED TO SHOW THE ACTUAL CIRCUIT NUMBERS TO BE UTILIZED. AT THE SAME TIME THE CIRCUITS LISTED AS "EXISTING CIRCUIT" ON THE PANEL SCHEDULES SHALL BE TRACED OUT AND THE ACTUAL ROOM NUMBER AND LOAD NAME AND WATTAGE IDENTIFIED ON A MARKED UP COPY OF THE PANEL SCHEDULE AND FORWARDED TO THE ENGINEER. .4 MATERIALS: EXISTING MATERIALS AND EQUIPMENT REMOVED AS PART OF THIS WORK MAY NOT BE REINSTALLED UNLESS SPECIFICALLY NOTED ON THE DRAWINGS. EXISTING MATERIALS NOT TO BE REINSTALLED UNLESS SELECTED FOR RETENTION BY THE OWNER, WHICH THEN SHALL BE DELIVERED TO A LOCATION ON THE PREMISES SELECTED BY THE OWNER. .5 DEMOLITION: ELECTRICAL DEVICES, LIGHTING FIXTURES, AND RACEWAY SYSTEMS WITHIN THE PROJECT AREA THAT ARE NO LONGER IN USE AS A RESULT OF THIS CONTRACT SHALL BE REMOVED UNLESS OTHERWISE NOTED TO REMAIN OR BE REINSTALLED. .6 POWER OUTAGES: SCHEDULE ELECTRICAL SYSTEM(S) OUTAGES WITH THE OWNER AT LEAST 48 HOURS PRIOR TO PROPOSED OUTAGE.. ELECTRICAL SYSTEM(S) OUTAGE TO OWNER OCCUPIED AREAS SHALL NOT BE PERMITTED FROM 7:OOA.M. TO 6:OOP.M. ON ANY DAY OF THE WEEK. PREMIUM TIME SHALL BE INCLUDED IN THE BASE BID FOR ELECTRICAL SYSTEM(S) OUTAGES AND FOR OTHER WORK AS REQUIRED BY THE SCHEDULE OR OTHER DIVISIONS OF THE SPECIFICATIONS. 16100.0 BASIC MATERIALS AND METHODS: INCLUDES GENERAL REQUIREMENTS FOR MATERIALS AND INSTALLATION METHODS, CUTTING BUILDING CONSTRUCTION, PAINTING, CLEAN-UP, AND WORKMANSHIP. .1 SUBSTITUTIONS: SHALL BE REVIEWED BY THE ENGINEER FOR APPROVAL/REJECTION PRIOR TO BID. .2 WORKMANSHIP: SHALL BE OF THE BEST QUALITY AND PERFORMED BY EXPERIENCED ELECTRICIANS UNDER SUPERVISION OF AN EXPERIENCED FOREMAN. .3 SUBMITTALS: AFTER AWARD OF CONTRACT SUBMIT THREE COMMON BOUND BROCHURES (ONE COPY RETURNED TO CONTRACTOR) CONTAINING CATALOG CUTS AND/OR SHOP DRAWINGS FOR THE FOLLOWING ITEMS: WIRING DEVICES MOTOR STARTERS DISCONNECTS AND FUSED SWITCHES LIGHTING FIXTURES AND BALLASTS .4 CUTTING AND PATCHING: DO NOT CUT STRUCTURAL MEMBERS. ALL CONSTRUCTION MATERIALS DAMAGED OR CUT INTO DURING THE INSTALLATION OF THIS WORK MUST BE REPAIRED OR REPLACED WITH MATERIALS BY SKILLED LABOR EXPERIENCED IN THAT PARTICULAR BUILDING TRADE. .5 PAINTING:REPAINT ANY ELECTRICAL ITEMS SCRATCHED OR MARRED IN SHIPMENT OR INSTALLATION. .6 CLEAN UP: CONTINUALLY REMOVE DEBRIS, CUTTINGS, CRATES, CARTONS, ETC. CAREFULLY CLEAN WIRING DEVICES, COVER PLATES, LIGHT FIXTURES, ETC., TO REMOVE PAINT AND PLASTER, ETC_ 16110.0 RACEWAYS: PROVIDE RACEWAY SYSTEM COMPLETE AND IN CONFORMANCE WITH CODE. INSTALL RACEWAYS CONCEALED IN CONSTRUCTION FOR ALL AREAS UNLESS EXPOSED RACEWAYS ARE SPECIFICALLY SHOWN. .1 INTERIOR RACEWAYS: ELECTRICAL METALLIC TUBING (EMT) WITH STEEL COMPRESSION OR SET SCREW FITTINGS. INDENTOR, DRIVE -ON AND PRESSURE CAST ON DIE CAST TYPE SET SCREW FITTINGS ARE NOT ACCEPTABLE. UNLESS OTHERWISE NOTED 1/2" MINIMUM. FLEXIBLE RACEWAYS: GALVANIZED FLEXIBLE STEEL CONDUIT FOR DRY LOCATIONS. MAXIMUM LENGTH 6 FEET IN ANY GROUND RETURN PATH. NOT PERMITTED FOR EMERGENCY SYSTEM WIRING. .2 SURFACE METAL RACEWAY. FORMED STEEL TYPE. STANDARD FACTORY PAINTED FINISH. PROVIDE FOR ALL EXPOSED RACEWAYS IN FINISHED AREAS, INSTALL PARALLEL TO A BUILDING SURFACE (I.E. WALL, CEILING, FLOOR). .3 RACEWAY PENETRATIONS: PENETRATIONS THROUGH FIRE RATED CONSTRUCTION SHALL BE SEALED USING 3M CP -25 FIRE BARRIER CAULK UL LISTED SYSTEM NO. WL1001 16120.0 CONDUCTORS AND TERMINATIONS: PROVIDE ALL WIRE AND CABLE COMPLETE. .1 COPPER, INSULATED FOR 60OV. ALUMINUM OR COPPER CLAD ALUMINUM CONDUCTORS NOT PERMITTED. TYPE THW, THHN/THWN OR XHHW. NUMBER 12 AWG MINIMUM FOR POWER AND LIGHTING CIRCUITS. .2 SPLICES: SOLDERLESS TYPE ONLY. PREINSULATED "TWIST -ON" TYPE (LIMITED TO SIZE #10 AND SMALLER). BOLT OR COMPRESSION SET TYPE WITH APPUCAT10N OF PREFORMED INSULATED COVER, HEAT SHRINKABLE TUBING OR PLASTIC INSULATED TAPE ACCEPTABLE FOR ALL SIZES. .3 TERMINATIONS: COMPRESSION SET, BOLTED OR SCREW TERMINAL. CONDUCTORS #12 AND SMALLER SHALL UTILIZE EYE OR FORKED TONGUE TYPE COMPRESSION SET TERMINATOR WHEN TERMINATION IS TO A BOLTED SCREW SET TYPE TERMINAL BLOCK OR TERMINAL CABINET. a 16122.0 METAL CLAD CABLE: NOT PERMITTED UNLESS SPECIFICALLY AUTHORIZED IN WRITING BY PROJECT MANAGER. 16130.0 OUTLET AND PULL BOXES: PROVIDE OUTLET BOXES FOR DEVICES SUCH AS RECEPTACLES, SWITCHES AND LIGHT FIXTURES AND PULL BOXES AS REQUIRED IN THE CONDUIT SYSTEM PER THE NATIONAL ELECTRICAL CODE. COORDINATE LOCATIONS OF ALL OUTLET BOXES WITH ARCHITECTURAL ELEVATIONS AND MILLWORK DETAILS PRIOR TO ROUGH -IN. NOTIFY ARCHITECTS IMMEDIATELY OF ANY DISCREPANCIES. ATTEND OUTLET BOX WALK-THROUGH WITH ARCHITECT AND OWNER PRIOR TO INSTALLING CONDUIT AND CONDUCTORS TO BOXES. ALLOW FOR MOVING OF BOXES WITHIN 5'. .1 INTERIOR WIRING: PRESSED STEEL, ZINC COATED WITH BRACKETS AND PLASTER RING WHERE APPLICABLE. OUTLET BOXES SHALL BE FIRMLY ANCHORED TO WALL STUDS, CUT IN BOXES ARE NOT PERMITTED. MOUNT OUTLET BOXES FOR RECEPTACLES AND OTHER DEVICES AT 18", OR MATCH EXISTING OUTLET HEIGHTS. 16140.0 SWITCHES AND RECEPTACLES: PROVIDE ALL WIRING DEVICES AND COVERPLATES. .1COLOR: REFER TO GENERAL NOTES AND FLAG NOTES ON PLANS. COORDINATE WITH ARCHITECT PRIOR TO ORDERING. THE STANDARD DEVICE & FACEPLATE COLOR FOR TISHMAN-SPEYER, 520 PIKE BUILDING IS IVORY, CONFIRM ALL DEVICE/FACEPLATE COLORS WITH ARCHITECT/OWNER PRIOR TO ORDERING EQUIPMENT. .2 SWITCHES: SPECIFICATION GRADE, FEDERAL SPECIFICATION WS -896, BACK AND SIDE WIRED, RATED 277 VOLT, 20 AMP. PROVIDE SINGLE POLE, DOUBLE POLE, KEYED, 3 -WAY, 4 -WAY, PILOT LIGHT, LOCKING TYPE OR AS REQUIRED. ARROW HART 1991-I, BRYANT 4901-I, EAGLE 2221V, GENERAL ELECTRIC GE 5951-2G, HUBBELL 1221-I, LEVITON 1221-I, PASS & SEYMOUR 20AC1-I. .3 OCCUPANCY SENSOR SWITCHES: SPECIFICATION GRADE, INFRARED OCCUPANCY SENSOR RATED 1800 VA ® 120 VOLTS, 4000 VA @ 277 VOLTS WITH SELF ADAPTIVE TECHNOLOGY. 180 DEGREE FIELD OF VIEW, 2100 SF OF COVERAGE. LEVITON ODS15-ID-I. .4 RECEPTACLES OFFICE AREAS: SPECIFICATION GRADE, FEDERAL SPECIFICATION WC -596F, BACK AND SIDE WIRED, DUPLEX NEMA 5-15R CONFIGURATION 15 AMP, 120V), NYLON FACE, UNLESS SHOWN OTHERWISE. ARROW HART 5252-1, BRYANT 5252-I, EAGLE 5252V, GENERAL ELECTRIC GE 5252-2, HUBBELL 5252-I, LEVITON 5252-I, OR PASS & SEYMOUR 5252-1. .5 GROUND FAULT RECEPTACLES: SPECIFICATION GRADE DUPLEX RECEPTACLE WITH 4 - 6 MILLIAMPS LEAKAGE CURRENT TRIP LEVEL. IVORY COLOR. HUBBELL GF -5262, PASS & SEYMOUR 1591 -SI. .6 INTERIOR DEVICE PLATES: REFER TO SECTION 16140.1 .7 MULTIOUTLET ASSEMBLY: OUTLET SPACING SHALL BE 12" ON CENTER EXCEPT SHALL BE LOCATED WITHIN 0'-8" OF EACH END AND NO RECEPTACLES SHALL BE INSTALLED OVER SINKS. ALL ASSEMBLIES SHALL CONTAIN GREEN GROUND WIRE. PROVIDE .040" THICK STEEL ASSEMBLY WITH STANDARD FACTORY BUFF PAINTED FINISH. WIREMOLD 20GBA-12 SERIES OR EQUIVALENT BY WALKER. 16500.0 LIGHTING: PROVIDE A LIGHTING SYSTEM AS SHOWN ON THE CONTRACT DRAWINGS COMPLETE AND FULLY OPERATIONAL AND IN CONFORMANCE WITH CODE AND U.L. LISTING REQUIREMENTS. .1 CATALOG NUMBERS: ARE A DESIGN SERIES REFERENCE ONLY AND THE SIZE OF THE FIXTURE PROVIDED SHALL CORRESPOND WITH THE NUMBER OF LAMPS, WATTAGE CEILING TYPE AND/OR SIZE SHOWN. VERIFY ACTUAL REQUIREMENTS PRIOR TO ORDERING FIXTURES. .2 LAMPS: FLUORESCENT TYPE: BI -PIN, T-8 RAPID START, 32 WATT, 3500 K COLOR TEMPERATURE UNLESS OTHERWISE NOTED. COMPACT TRT(TRIPLE-TUBE) AND DTT(DOUBLE-TUBE), 3500 K COLOR TEMPERATURE UNLESS OTHERWISE NOTED. FOR FLUORESCENT LAMPS OPERATED ON DIMMING BALLASTS, OPERATE LAMPS AT FULL OUTPUT FOR 100 HOURS (CONTINUOUS BURN) BEFORE DIMMING. .3 ELECTRONIC BALLASTS: SHALL BE U.L AND CMB (WHERE APPLICABLE) LISTED, NON -PCB, HIGH POWER FACTOR TYPE MEETING THE REQUIREMENTS OF IEEE PUBLICATION 587, CATEGORY A (TRANSIENTS) AND FCC PART 18. TOTAL HARMONIC DISTORTION SHALL BE LESS THAN 20% OF THE INPUT CURRENT. CURRENT CREST FACTOR SHALL NOT BE GREATER THAN 1.6. OPERATION FREQUENCY SHALL BE BETWEEN 20 AND 60 KHZ. BALLASTS SHALL BE WARRANTED BY THE MANUFACTURER FOR A PERIOD OF NOT LESS THAN THREE YEARS. EBT SSB1/LH SERIES, MOTOROLA MRN SERIES, VALMONT SR/GO1 SERIES OR AS SPECIFICALLY NOTED IN THE LIGHT FIXTURE SCHEDULE. .4 FIXTURE SUPPORT: PROVIDE TWO #14 EARTHQUAKE CHAINS OR #9 WIRE SECURED (AT DIAGONALLY OPPOSITE FIXTURE CORNERS) TO STRUCTURAL MEMBERS ABOVE SUSPENDED CEILING FOR EACH RECESSED FLUORESCENT FIXTURE. .5 PROVIDE LIGHTING SYSTEM(S) COMMISIONING PER THE 2012 WASHINGTON STATE ENERGY CODE (WSEC) PROVIDE LIGHTING CONTROL (TIMECLOCKS, OCCUPANCY SENSORS, PHOTOCELLS, ETC.) ADJUSTMENTS AND TRAINING TO THE OWNER PER WSEC AS REQUIRED, REFER TO WSEC 408.3 FOR REQUIREMENTS. 16721.0 FIRE ALARM SYSTEM: PROVIDE A ZONED, NON -CODED, ANNUNCIATED FIRE DETECTION AND ALARM SYSTEM THAT FULLY COMPLIES WITH FEDERAL, STATE AND LOCAL FIRE CODES. THE SYSTEM SHALL BE AN EXTENSION OF THE CORE AND SHELL BUILDING SYSTEM WHICH IS AN ADDRESSABLE SYSTEM. IF ANY CONFLICT OCCURS BETWEEN GOVERNMENT ADOPTED CODE RULES AND THESE CONTRACT DOCUMENTS, THE CODES ARE TO GOVERN. .1 OPERATION: ACTIVATION OF ANY INITIATION DEVICE SHALL IMMEDIATELY CAUSE ALL FIRE ALARM SPEAKERS TO SOUND A CONTINUOUS CHIME TONE SIGNAL, VISUAL ALARM LIGHTS TO FLASH, RELEASE SMOKE BARRIER DOORS, ILLUMINATE THE ZONE ANNUNCIATOR LIGHT, TRANSMIT AN ALARM TO THE FIRE DEPARTMENT. AIR HANDLING EQUIPMENT AFFECTING THE ZONE OF THE FIRE TO BE AUTOMATICALLY SHUTDOWN ONLY WHEN ACTIVATED BY THE SMOKE DETECTOR LOCATED IN THE SUPPLY AIR DUCT DOWNSTREAM OF THE FILTERS. .2 SUPERVISION: THE SYSTEM SHALL BE SUPERVISED TO SOUND AN AUDIBLE AND VISUAL TROUBLE SIGNAL UPON THE OCCURRENCE OF ANY OPEN OR GROUNDED CIRCUITS. PROVIDE A SEPARATE INDICATOR LAMP FOR EACH ZONE. .3 SPRINKLER SYSTEM MONITORING: COORDINATE WITH THE SPRINKLER SYSTEM SUBCONTRACTOR AND PROVIDE CIRCUITS AND ANNUNCIATION AS REQUIRED BY THE AHJ TO SUPERVISE PIV, OSY GATE VALVE POSITIONS AND WATER FLOW SWITCHES. .4 CONTRACTOR DESIGN: RACEWAYS, ROUTING AND SYSTEM WIRING IS NOT SHOWN ON THE PLANS AND IT SHALL BE THE RESPONSIBILITY OF THE FIRE ALARM SYSTEM SUPPLIER TO DESIGN CONDUIT ROUTING AND WIRING AND TO SHOW THE SAME ON THE SHOP DRAWINGS. CIRCUITS SHALL BE CLASS B. .5 SHOP DRAWINGS: PREPARE FLOOR PLAN BACKGROUNDS AND SHOW CONDUIT ROUTING, DEVICE LOCATIONS, END OF LINE RESISTORS, AND WIRE COUNT BETWEEN DEVICES. SHOW FIRE ALARM ZONES. UPDATED DRAWINGS OF THE ORIGINAL FIRE ALARM SHOP DRAWINGS ARE ACCEPTABLE. SUBMIT DRAWINGS AND OBTAIN APPROVAL OF THE "AUTHORITY HAVING JURISDICTION" (AHJ). .6 APPROVED MANUFACTURERS: MATCH EXISTING EQUIPMENT (PYROTONICS EQUIPMENT SHOWN FOR REFERENCE ONLY). .7 COMPONENTS: SHALL BE MANUFACTURERS STANDARD. MANUAL STATIONS: BREAK GLASS, NON -CODED, SEMI -FLUSH MOUNTED WITH FIRE RED ENAMEL FINISH. PYROTRONICS MSI -10B. SMOKE DETECTORS: PHOTOELECTRIC TYPE, LOW PROFILE, SEMI -FLUSH MOUNTED WITH VISUAL INDICATION OF TROUBLE/ALARM CONDITION. PYROTRONICS FP -11 WITH DB -11 BASE. HEAT DETECTORS: COMBINATION SPOT/RATE OF RISE TYPE, NON SELF RESTORING WITH INDICATION OF ACTUATED CONDITION. CHEMTRONICS #6031356. DUCT SMOKE DETECTORS: PHOTOELECTRIC TYPE WITH REMOTE TEST STATION AND ALARM INDICATOR. IN DUCT TYPE: SUITABLE FOR 0-600 FT/ MIN AIR VELOCITY. PYROTRONICS AD -11 XPR. SAMPLING TUBE TYPE: DESIGN AND DIMENSIONS AS RECOMMENDED BY THE MANUFACTURER FOR THE SPECIFIC DUCT SIZE, AIR VELOCITY, AND INSTALLATION CONDITIONS WHERE APPLIED. PROVIDE AUXILIARY RELAY PROGRAMMED TO CLOSE THE ASSOCIATED SMOKE DAMPER UPON ACTIVATION OF DUCT SMOKE DETECTOR AND FUTURE INDEPENDENT CONTROL FROM THE BUILDING AUTOMATION SYSTEM. PROVIDE A REMOTE INDICATOR LIGHT AND TEST STATION WHEN THE SMOKE DETECTOR IS NOT READILY VISIBLE WHEN STANDING IN THE ROOM. SIMILAR TO SIMPLEX 2098-9648. VISUAL ALARM LIGHTS: VISUAL ALARM LIGHTS: LED STROBE LIGHTS, UL LISTED TO STANDARD 1971. WALL MOUNTED WHITE HOUSING WITH RED "FIRE"AETTERING. WHEELOCK EXCEDER SERIES (15/30/75/95 CD); STROBE ONLY #LSTWC. SPEAKER ONLY. MULTI -TAPPED SPEAKER WITH LINE MATCHING TRANSFORMER FOR 1/4, 1/2, 1 OR 2 WATT OUTPUT ON A 25 VOLT LINE. FREQUENCY RANGE 400-4000 HZ PRODUCING 84DB AT 10 FEET AT 1 WATT INPUT. UL LISTED TO STANDARD 1480. WHITE HOUSING WITH RED 'FIRE" LETTERING WHEELOCK EXCEDER SERIES ; #LSPKWC COMBINATION SPEAKER/ VISUAL ALARM LIGHT: MULTI -TAPPED SPEAKER WITH LINE MATCHING TRANSFORMER FOR 1/4, 1/2, 1 OR 2 WATT OUTPUT ON A 25 VOLT LINE. FREQUENCY RANGE 400-4000 HZ PRODUCING 84DB AT 10 FEET AT 1 WATT INPUT. UL LISTED TO STANDARD 1480. VISUAL ALARM LIGHT 110 CANDELA, U.L LISTED TO STANDARD 1971. WHITE HOUSING WITH RED "FIRE" LETTERING. WHEELOCK EXCEDER SERIES ; SPEAKER/STROBE CEILING #LSPSTWC 8 INSTALLATION: OBTAIN A PERMIT AND APPROVED SHOP DRAWINGS FROM THE AHJ PRIOR TO INSTALLING EQUIPMENT. ALL WIRING SHALL BE CONTAINED IN STEEL RACEWAYS. AFFIX PERMANENT WIRE MARKERS TO ALL CONDUCTORS AT TERMINATIONS. NUMBER 16 GAUGE WIRE SHALL HAVE A MAXIMUM OF 7 STRANDS. 9 TESTING: TESTING SHALL BE IN COMPLIANCE WITH NFPA 72, CHAPTER 7. IN ADDITION, TEST EACH DEVICE, ALL FEATURES OF THE SYSTEM ON NORMAL AND BATTERY POWER AND DEMONSTRATE SATISFACTORY OPERATION TO THE ENGINEER AND THE AUTHORITY HAVING JURISDICTION. OBTAIN APPROVAL OF THE AHJ IN WRITING. 10 RECORD DOCUMENTS: PROVIDE OPERATION AND MAINTENANCE MANUALS AND RECORD DRAWINGS TO SHOW ACTUAL ROUTING OF RACEWAYS, CABLE TYPES AND NUMBERS AND WIRING DIAGRAMS. 11 INSTRUCTION: DESCRIBE AND DEMONSTRATE ALL MAINTENANCE AND OPERATIONAL ASPECTS OF THE SYSTEM TO PERSONNEL SELECTED BY THE OWNER. 16740.0 TELEPHONE, COMPUTER SYSTEMS: PROVIDE RACEWAY AND OUTLET BOXES READY FOR THE INSTALLATION OF CABLES BY OTHERS. .1 WALL OUTLETS: PROVIDE A 4" SQUARE, 2-1/8" DEEP OUTLET BOX AND SINGLE GANG PLASTER RING. .2 RACEWAYS: PROVIDE A 3/4" RACEWAY FROM EACH TELEPHONE/ COMPUTER OUTLET TO THE CEILING SPACE. MULTIPLE OUTLET BOXES SHALL NOT BE CONNECTED TOGETHER BY A COMMON RACEWAY HOWEVER, THE VERTICAL RACEWAYS MAY BE ROUTED TO AN ACCESSIBLE J -BOX ABOVE THE CEILING AND THEN HOME RUN TO THE CORRIDOR CEILING WITH A SINGLE RACEWAY. PROVIDE PLASTIC BUSHING ON ALL RACEWAY ENDS. .3 CONDUCTORS, OUTLETS, AND COVERPLATES: BY LOW -VOLTAGE CONTRACTOR. .4 PULL CORDS: PROVIDE A NYLON TYPE PULL CORD IN EACH RACEWAY AND SECTION OF CABLE TRAY BACK TO THE TELEPHONE TERMINAL BOARD. A:'11IT FOR: OM,sctlanical ❑ Electrical Plumbing obas Piping C t1 Of Tukl vdIa 11 1'-T�,nt DiVISIOP 1 REVISIONS � Of Work writhol_k pro approval of e Tul<rvila Building Division. ROTE: Revisions will require a near p'an submittal , and may in-Ciude additional plan reviewi fses. t , RLE COPY Permit No. P-wo � Iw Plan raviev., I:i subject to errors and QT : 2slom. Approval of COTI� I uVoi9 [101CIUMents does nol, au. L',tC„ 3 the Violation of tiny adopted Cotte or ordinance. R ._, i of approved Field Copy and Conditions is ack-noEv,wd� J: By: J,��-- Date: 0 1 Iz 11-7 City of Tukwila BUILDING DIVISION EO.01 ELECTRICAL LEGEND & SPECIFICATIONS EO.02 LIGHTING FIXTURE SCHEDULE, NREC EO.03 MECHANICAL EQUIPMENT SCHEDULE E2.01 PARKING LEVEL POWER & COMMUNICATIONS PLAN E2.02 LEVEL 1 POWER & COMMUNICATIONS PLAN E2.03 LEVEL 2 POWER & COMMUNICATIONS PLAN E2.04 ROOF POWER & COMMUNICATIONS PLAN E3.01 PARKING LEVEL LIGHTING PLAN E3.02 LEVEL 1 LIGHTING PLAN E3.03 LEVEL 2 LIGHTING PLAN EL3.01 PARKING LEVEL LIGHTING CALCULATION PLAN E4.01 PARKING LEVEL MECHANICAL POWER PLAN E4.02 LEVEL 1 MECHANICAL POWER PLAN E4.03 LEVEL 2 MECHANICAL POWER PLAN E4.04 ROOF MECHANICAL POWER PLAN E8.01 ELECTRICAL RISER DIAGRAMS E9.01 PANEL SCHEDULES Cl CF'U9L NOV 212016 PERMIT CENTER JACKSON I MAIN ARCH I T E C T U R E 311 FIRST AVENUE SOUTH SEATTLE, WA 98104 t 206.324.4800 WWW.JACKSONMAIN.COM 19515 North Creek Parkway, Suite 302 Bothell, Washington 98011 Phone: 425-402-9400 Fax: 425-402-9402 i i i PROJECT MGR.: ELECTRICAL LEGEND DRAWN BY: Z POWER RECEPTACLES & OUTLETS LIGHT FIXTURES & CONTROLS ABBREVIATIONS 1:@ DUPLEX RECEPTACLE O SURFACE COLING MOUNTED DOWNUGHT A (200A) (AFTER A NUMBER) = AMPS rn DOUBLE DUPLEX RECEPTACLE O° RECESSED DOWNLIGHT (ROUND) AF(200AF) (AFTER A NUMBER) = FUSE SIZE IN AMPS CV w� U 9 RECESSED DOWNLIGHT (SQUARE) AFF ABOVE FINISHED FLOOR I® DUPLEX GFCI RECEPTACLE � O � . =. OO ❑ ! PENDANT MOUNTED FIXTURE OR CHANDELIER AL ALUMINUM DOUBLE DUPLEX GFCI RECEPTACLE LL o LO ATS AUTOMATIC TRANSFER SWITCH I Q POINT SOURCE WALL MOUNTED FIXTURE URE SINGLE P 0 DOUBLE DUPLEX RECEPTACLE MOUNTED IN CEILING BKR BREAKER � W SURFACE MOUNTED LINEAR FIXTURE C CONDUIT WD DUPLEX RECEPTACLE MOUNTED +4" TO CENTER OF DEVICE ABOVE COUNTER OR TOP OF BACKSPLASH, WHEN ® RECESSED LINEAR FIXTURE CKT CIRCUIT W PRESENT (U.O.N.). COORDINATE EXACT LOCATION WITH © PENDANT MOUNTED LINEAR FIXTURE CL CENTERLINE MILLWORK DETAILS PRIOR TO ROUGH -IN. W J PENDANT MOUNTED LINEAR WALLWASHER CLG CEILING to DOUBLE DUPLEX RECEPTACLE MOUNTED +4" TO CENTER OF o Ww W DEVICE ABOVE COUNTER OR TOP OF BACKSPLASH, WHEN===.a LINEAR UNDERCOUNTER FIXTURE C.O. CONDUIT ONLY PRESENT (U.O.N.) COORDINATE EXACT LOCATION WITH MILLWORK -o LINEAR LED COVE, TRACK OR TAPE LIGHT (LENGTH AS CU COPPER DETAILS PRIOR TO ROUGH -IN. SHOWN ON PLAN, TRANSFORMER(S) SHOWN AS DIA DIAMETER 119 DUPLEX GFCI RECEPTACLE MOUNTED +4" TO CENTER OF REQUIRED) DISC DISCONNECT p DEVICE ABOVE COUNTER OR BACKSPLASH, WHEN PRESENT -Z--ZO TRACK LIGHT (LENGTH AS SHOWN ON PLAN) 1 (U.O.N.) COORDINATE EXACT LOCATION WITH MILLWORK W 0U' DISP DISPENSER DETAILS PRIOR TO ROUGH -IN. RECESSED WALLWASHER DF DRINKING FOUNTAIN 0 DOUBLE DUPLEX GFCI RECEPTACLE MOUNTED +4" TO CENTER OF ® RECESSED EMERGENCY EGRESS 2'x4' FIXTURE DW DISHWASHER DEVICE ABOVE COUNTER OR TOP OF BACKSPLASH, WHEN PRESENT ECB ENCLOSED CIRCUIT BREAKER (U.O.N.) COORDINATE EXACT LOCATION WITH MILLWORK DETAILS ® SURFACE LINEAR EMERGENCY EGRESS FIXTURE (E) EXISTING (USED AS SYMBOL DESIGNATION) PRIOR TO ROUGH -IN. O co V U � Q RECESSED EMERGENCY EGRESS DOWNLIGHT EMT ELECTRICAL METALLIC TUBING 0 DOUBLE DUPLEX RECEPTACLE WITH 1/2 SWITCHED SURFACE EMERGENCY EGRESS DOWNLIGHT EXTG EXISTING (USED AS ABBREVIATION IN TEXT) AWP GFCI RECEPTACLE WITH WEATHERPROOF WHILE -IN -USE COVER FLR FLOOR ® UNIVERSAL/CEILING MOUNTED EXIT SIGN �O� FLOOR POKE-THRU WITH DEVICES SHOWN WALL MOUNTED EXIT SIGN IMP FIRE ALARM ANNUNCIATOR PANEL QN!NN NN FACP FIRE ALARM CONTROL PANEL SINGLE SPECIAL PURPOSE RECEPTACLE ® ® DIRECTIONAL EXIT SIGN (ARROWS INDICATE ONE OR TWO SIDES FSD FIRE SMOKE DAMPER IT of AND DIRECTION INDICATED) Q JUNCTION BOX WITH BLANK COVER o� FUT FUTURE NOTE: LIGHTING FIXTURE SYMBOLS SHOW LENGTH, MOUNTING & EMERGENCY GEN GENERATOR io FURNITURE SYSTEM POWER FEED. MAKE FINAL CONNECTION EGRESS INFORMATION ONLY. REFER TO FIXTURE DESIGNATIONS & LIGHTING TO FURNITURE SYSTEM FLEX CONDUIT (PROVIDED BY OTHERS). FIXTURE SCHEDULE FOR LAMP TYPE & OTHER FIXTURE SPECIFICS. GFCI GROUND FAULT CIRCUIT INTERRUPTER VERIFY REQUIREMENTS. GND GROUND TELE/COMMUNICATIONS SYSTEM DEVICES LIGHTING CONTROLS HTR HEATER ® TELEPHONE S SINGLE POLE LIGHT SWITCH HWT HOT WATER TANK (LOWER CASE SUBSCRIPT DEFINES LIGHTS THAT ARE TO BE HOA HAND -OFF -AUTO W WALL MOUNTED TELEPHONE (VERIFY MOUNTING HEIGHT) SWITCHED -MATCH WITH U=TTERS AT FIXTURE) kCMIL THOUSANDS OF CIRCULAR MILS ® SINGLE GANG TO OPENING. PROVIDE 2 -GANG S3 THREE POLE LIGHT SWITCH KVA 1000 VOLT AMPERES JUNCTION BOX WITH SINGLE -GANG MUD RING & 3/4"C.O. S DIMMER SWITCH KW 1000 WATTS TO ACCESSIBLE CEILING SPACE. 118 S OCCUPANCY SENSOR LIGHT SWITCH (NUMBER DEFINES RELAY LCP LIGHTING CONTROL PANEL TELEPHONE TERMINAL BOARD - 3/4" FIRE RESISTANT NUMBER IN LIGHTING CONTROL PANEL -SEE SCHEDULE) LT LIGHT PLYWOOD, 8' HIGH x LENGTH SHOWN ON PLAN S VACANCY SENSOR LIGHT SWITCH LTS(LTG) LIGHTS (LIGHTING) JUNCTION BOX & CONDUIT TO ACCESSIBLE CEILING SPACE LIGHT SWITCH WITH PILOT LIGHT LV LOW VOLTAGE FOR FURNITURE SYSTEM TELE/DATA CONNECTIONS. PROVIDE CONDUIT REQUIRED FOR QUANTITY OF DATA CABLES. VERIFY SK KEYED SWITCH MCB MAIN CIRCUIT BREAKER QUANTITY OF DATA CABLES WITH OWNER PRIOR TO ROUGH -IN. SLV = LOW VOLTAGE, b = AREA TO BE CONTROLLED BY PHOTOCELL MECH MECHANICAL ❑TV TELEVISION OUTLET b R1 R# = RELAY IN LIGHTING CONTROL PANEL MLO MAIN LUGS ONLY S# = SENSOR ZONE N3R NEMA 3R SERVICE GEAR - AS SHOWN ON PLANS Q CEILING MOUNTED VACANCY SENSOR NIC NOT IN CONTRACT CIRCUIT BREAKER PANELBOARD os CEILING MOUNTED OCCUPANCY SENSOR OC ON CENTER G LOAD CENTER os WALL MOUNTED OCCUPANCY SENSOR OH OVERHEAD o TERMINAL CABINET PHOTOCELL LIGHT SENSOR OS OCCUPANCY SENSOR SWITCHBOARD OR MOTOR CONTROL CENTER, SIZE PC PHOTOCELL AS SHOWN ON PLANS PNL PANELBOARD NOTES AND MISCELLANEOUS SYMBOLS PT I DRY TYPE TRANSFORMER (SEE NOTES & RISER REC RECEPTACLE(S) DIAGRAM FOR SIZE) [�> FLAGNOTE - IDENTIFIES A SPECIFIC ITEM ON A DRAWING. REF REFRIGERATOR CONDUITS AND CIRCUITING COORESPONDS TO A SCHEDULE IN THE ELECTRICAL SET THAT (R) RELOCATED EXISTING EXPLAINS DETAILS OR FEATURES OF THAT ITEM. RQMTS REQUIREMENTS WIRING LOCATED IN CEILING OR WALL FF -3 MECHANICAL FLAG - DEFINES MECHANICAL EQUIPMENT AND SCL SEATTLE CITY LIGHT ---- WIRING CONCEALED UNDER FLOOR OR UNDERGROUND COORESPONDS TO DESIGNATIONS IN MECHANICAL PLANS AND SCHEDULES. COORESPONDS MECHANICAL CONNECTION SCHEDULE SPD SURGE PROTECTIVE DEVICE - CONDUIT HOME -RUN IN THE ELECTRICAL SET. SQ SQUARE -H--11FAk/- SLASHES ACROSS CONDUIT INDICATE NUMBER OF WIRES - SHORT = HOT, LONG = NEUTRAL 200 EQUIPMENT FLAG -DEFINES SPECIAL (IE: COOKING) EQUIPMENT SW SWITCHWITHIN ON A PLAN AND COORESPONDS TO DESIGNATIONS IN AN TBD TO BE DETERMINED ISOLATED GROUND WIRE EQUIPMENT SCHEDULE IN THE ELECTRICAL SET. TTB TELEPHONE TERMINAL BOARD l+ GROUND WIRE CONDUIT TURNS AND CHANGES ELEVATION AT THIS POINT REVISION CLOUD AND FLAG - CLOUD SURROUNDS INFORMATION TYP TYPICAL THAT HAS BEEN REVISED. FLAG IDENTIFIES THE REVISION IN UC UNDER COUNTER -� CONDUIT STUB -UP 1 WHICH THE CHANGES WERE MADE. -� S- CONDUIT BREAK UG UNDERGROUND --i CONDUIT CONTINUES ELSEWHERE (NOTED ON PLAN) O DETAIL NUMBER - APPEARS IN FRONT OF A TITLE ON DRAWINGS. UL UNDERWRITER'S LABORATORY 3 IDENTIFICATION SYMBOL - CROSS REFERENCES INFORMATION IN U.O.N. UNLESS OTHERWISE NOTED EQUIPMENT CONNECTIONS & CONTROLS E1.1 ONE AREA WITH A DETAIL (TOP #) AND SHEET (BOTTOM #) IN U11L UTILITY ANOTHER IN THE ELECTRICAL SET. VA VOLT AMPERES ® EQUIPMENT CONNECTION NOTE: ALL FIXTURES AND EQUIPMENT SHOWN ON PLANS IN STANDARD VS VACANCY SENSOR WALL MOUNTED EQUIPMENT CONNECTION (HEAVY) LINE WEIGHT ARE NEW OR RELOCATED WORK. FIXTURES AND W WATTS MOTOR CONNECTION EQUIPMENT SHOWN IN LIGHT LINE WEIGHT WITH (E) NEXT TO THEM INDICATE EXISTING TO REMAIN. SYMBOLS SHOWN AS DASHED INDICATE ITEMS WAP WIRELESS ACCESS POINT 4 FAN CONNECTION TO BE REMOVED OR DEMOLISHED. THIS APPLIES UNLESS NOTED OTHERWISE WC WATER COOLER ON PLANS. ❑1 DISCONNECT SWITCH W/0 WITHOUT QI FUSED DISCONNECT SWITCH WP WEATHERPROOF ® MAGNETIC MOTOR STARTER XFMR TRANSFORMER COMBINATION STARTER AND DISCONNECT ENCLOSED CIRCUIT BREAKER ••• HAND/OFF/AUTO SWITCH "" START -STOP PUSHBUTTON SWITCH F±1 PUSHBUTTON SWITCH S"' MOTOR RATED SWITCH A:'11IT FOR: OM,sctlanical ❑ Electrical Plumbing obas Piping C t1 Of Tukl vdIa 11 1'-T�,nt DiVISIOP 1 REVISIONS � Of Work writhol_k pro approval of e Tul<rvila Building Division. ROTE: Revisions will require a near p'an submittal , and may in-Ciude additional plan reviewi fses. t , RLE COPY Permit No. P-wo � Iw Plan raviev., I:i subject to errors and QT : 2slom. Approval of COTI� I uVoi9 [101CIUMents does nol, au. L',tC„ 3 the Violation of tiny adopted Cotte or ordinance. R ._, i of approved Field Copy and Conditions is ack-noEv,wd� J: By: J,��-- Date: 0 1 Iz 11-7 City of Tukwila BUILDING DIVISION EO.01 ELECTRICAL LEGEND & SPECIFICATIONS EO.02 LIGHTING FIXTURE SCHEDULE, NREC EO.03 MECHANICAL EQUIPMENT SCHEDULE E2.01 PARKING LEVEL POWER & COMMUNICATIONS PLAN E2.02 LEVEL 1 POWER & COMMUNICATIONS PLAN E2.03 LEVEL 2 POWER & COMMUNICATIONS PLAN E2.04 ROOF POWER & COMMUNICATIONS PLAN E3.01 PARKING LEVEL LIGHTING PLAN E3.02 LEVEL 1 LIGHTING PLAN E3.03 LEVEL 2 LIGHTING PLAN EL3.01 PARKING LEVEL LIGHTING CALCULATION PLAN E4.01 PARKING LEVEL MECHANICAL POWER PLAN E4.02 LEVEL 1 MECHANICAL POWER PLAN E4.03 LEVEL 2 MECHANICAL POWER PLAN E4.04 ROOF MECHANICAL POWER PLAN E8.01 ELECTRICAL RISER DIAGRAMS E9.01 PANEL SCHEDULES Cl CF'U9L NOV 212016 PERMIT CENTER JACKSON I MAIN ARCH I T E C T U R E 311 FIRST AVENUE SOUTH SEATTLE, WA 98104 t 206.324.4800 WWW.JACKSONMAIN.COM 19515 North Creek Parkway, Suite 302 Bothell, Washington 98011 Phone: 425-402-9400 Fax: 425-402-9402 Mo i i i PROJECT MGR.: LM DRAWN BY: Z m0�.�0/� MSC O Em aa� W �. W rn NW {. - Q 4W F_ Q 11 CV w� U Q lib cr) I- J - �c) � O � . =. OO I- CV W LL o LO I- Mo z i i i PROJECT MGR.: LM DRAWN BY: Z m MSC O Em �. w � 00 o0 NW {. - Q z00 � U w U Q ��^^ W �c) W Q pLL J U W LL o o L0 I- z i i i PROJECT MGR.: LM DRAWN BY: CJP CHECKED BY: MSC O Em a V I I U) w � W Wi ziW z W W J O ~_ F - o Ww W U > > > m W Q0�o12�U W W Z p z p I- 1 W 0U' ULILI� O co V U i z 0 ' o o QN!NN NN o�I00N 00!- CC) IT of r-,00i"r i i o� DEC 0 9 2016 1 City of -Tukwila BUILDING DIVISION ' PROJECT NO.: 16040 / C16163 PROJECT MGR.: LM DRAWN BY: CJP CHECKED BY: MSC Em ELECTRICAL LEGEND & SPECIFICATIONS E02U JACKSON I MAIN ARCHITECTURE P.S. © 2015 Project Info Project Title: INSPIRUS CREDIT UNION Date 7/1/2016 Compliance Applicantlnformation. Provide contact information for individual viho can For Building Department Use forms do not respond to inquiries about compliance form information provided. For Building Department Company Name: CASE ENGINEERING require a password to ® Standard O Additional Efficiency Package Option O C406.3 Reduced Interior Lighting Power To comply with C406.3, the Proposed LPD shall be 25% lower than the Target LPA. Refer to C406.3 for additional requirements. Company Address: 19515 NORTH CREEK PKWAY SUITE 302, BOTHELL WA use. 18 Instructional and Location (plan #, room #) Space Type Applicant Name: STEPHANIE ENLOW calculating cells Watts Allowed (watts/ft2 x area) are wite- Parking area, interior Applicant Phone: 425-402-9400 EXT 16 protected. 2913 Applies to luminaires > 100 Watts Parking area, interior Applicant Email: STEPHANIE@CASEENG.COM Project Description 0 New Building 0 Addition ® Alteration El Plans Included LED Include PROJ-SUM form (included in envelope forms wrkbook) Wth lighting complliance forms. Building Additions Compliance Method —1 Interior lighting Exterior lighting 1453 Lighting systems in addition area comply with all applicable 1 o o Office: Open plan provisions as a stand alone new construction project i Refer to Section C502.2.6 for additional --------------------------------------------------- —-------- -------------------------*---------------- --- - requirements. Lighting systems in addition are combined with existing 13 13 2163 building lighting systems to demonstrate compliance j - - -- - - - -- - --- - - -- -- -- - -- - - - - -- - - -- - -- A--- ------ --------------------- 2120 Addition is combined with existing: Copy/print room Forinterior lighting projects, include new + existing interior lighting fixture vtattage in Proposed 0.580 Lighting Wattage table in LTG-iNT-BLD orLTG-INT-SPACE form. For exterior lighting projects, include new + existing exterior lighting fixture vtattage in Proposed 700 Tradable and Proposed Non -Tradable Lighting Wattage tables in LTG -EXT form. Interior and Exterior Lighting Power Interior lighting i Parking garage I Exterior lighting Lighting Alterations 50% or more of existing are replaced ® I 13 Q I Se/ectallLighting Posner and Lighting Control elements that apply to the scope Less than 50% of existing are replaced: 0 Q 0 ofthe retrofit project. If project includes a Gymnasium/fitness center. Exercise area combination ofspaces Inhere less than I Lamp and/or ballast replacement only13 13 13 50% of the existing fixtures are replaced -existing total wattage not increased i more of the fixtures are replaced in others, then fi some spaces, and not others, 50% or more replaced - Total lighting power of new + exisfing-to-remain fixtures shall comply Kith provide separate lighting total LPA per Sections C405.4.2 and C405.5.2. Include new + existing -to -remain fixtures in twpovre compliance forms for the tvw retrofit Proposed Lighting Wattage table in LTG-iNT-BLD, LTG -INT -SPACE or LTG -EXT form. conditions. Spaces undergoing the same Less than 50% replaced - Total lighting povwr of new+ existing -to -remain fixtures shall not exceed type of retrofit may be combined into one the total lighting povier prior to alteration. Include new + existing -to -remain fixtures in the Proposed lighfing pouter compliance form. Lighting Wattage table in LTG-iNT-BLD, LTG -INT -SPACE or LTG -EXT form. 0.600 50% threshold applies to numberof luminaires for interior spaces and parking garages, and total Refer to Section C503.6 for additional installed "attage for exterior luminaires. requirements. Lighting Controls Interior lighting Parking garage Exterior lighting F5 All alteration lighting controls shall be —"-__ _ _ _--_--- _"-__-_'.`-__------------*----- ---_ __--_---____. New wiring installed to serve added commissioned perC408.3. i fixtures and/or fixtures relocated to ® 13 0 VIBIA HALO 2332 SERIES. new circuit(s) New or moved lighting panel Q Q Q F6 SURFACE PENDANT MOUNTED LED RING LIGHT, DIAMETERS AS SHOWN ON ---------- ----- ----- --------------- -- --------------------- -- Interior space is reconfigured - 13 M-1 17 luminaires unchanged or relocated I -- PROJECT DOCUMENTS. REMOTE 20OW DRIVER FOR 12 AND 11' DIAMETER New wiring or circuit - For interior lighting, provide required manual controls per C405.2.3— occupancy sensor controls per C405.2.1, daylight responsive controls per C405.2.4 and application 0 No changes are being made to specific lighting controls per C405.2.5. For exterior lighting, provide required controls per C405.2.7. the interior or exterior lighting New or moved panel - Provide all applicable lighting controls as noted for New Wiring and automatic systems and existing space time sviitch controls per C405.2.2. uses and configuration are not Reconfigured interior space - Provide all required lighting controls that apply to a new interior changed. space. Application specific lighting control provisions per C405.2.5 do not apply to reconfigured Change of Space Use 0 Existing interior lighting systems in areas under -going a change in space use are upgraded to STEEL HOUSING, 35K, 3000. LUMENS WITH 0-10V DIMMING DRIVER - comply with LPAs for the new space types per Tables C405.4.2(1) or C405.4.2(2). identify interior spaces requiring LPD upgrade to the current Code in Proposed Lighting Wattage VIA OCCUPANCY SENSOR TURNS FIXTURE TO 50 PERCENT POWER table in LTG -INT -BLD or LTG -INT -SPACE form. Project Title: INSPIRUS CREDIT UNION Date 7/1/2016 Date 7/1/2016 Calculation Area NOTE 9 O O Addition- stand alone O Spaces where < 50% of ® Spaces where Z 50% of luminaires are replaced luminaires are replaced O Addition + existing O For Building Department Use LPA Calculation Type ® Standard O Additional Efficiency Package Option O C406.3 Reduced Interior Lighting Power To comply with C406.3, the Proposed LPD shall be 25% lower than the Target LPA. Refer to C406.3 for additional requirements. Maximum Allowed Lighting Wattage NOTE1 0 0 Addition- 0 Addition 18 stand alone + exist ng Location (plan #, room #) Space Type Ceiling Gross Interior HeightNO� z Area in ftz Allowed Watts per ftZ Watts Allowed (watts/ft2 x area) ext. wattage replaced wattage replaced Parking area, interior 19422 0.150 2913 Applies to luminaires > 100 Watts Parking area, interior 14 2700 0.150 405 LED Office: Enclosed 1633 0.890 1453 per fe or per If x fig (or x 10 Office: Open plan 6839 0.780 5334 F3 conference/meeting/multipurpose 2163 0.980 2120 AND DROPPED GLASS LENS. DEAD FRONT TRIM. Copy/print room 165 0.580 96 Restroom: all other 700 0.780 546 W Storage room 583 0.500 292 Gymnasium/fitness center. Exercise area 1085 0.580 629 FINISH AS SELECTED BY ARCHITECT. CENTER BETWEEN CEILING f— AND MIRROR. CENTER HORIZONTALLY WITH MIRROR Food preparation 250 0.790 198 Locker room 577 0.600 346 (U a OXYGEN APOLLO 3-5104-14 I� U�< I F5 Lobby Art/Exhibit Display Allowance from LTG -INT -DISPLAY NOTE a� Total Area 36117 Retail Display Allowance from LTG -INT -DISPLAY Allowed Watts 14333 '" Project Title: INSPIRUS CREDIT UNION Date 7/1/2016 Exterior LightingFor 1 18 Building Department Use DESCRIPTION 0 Zone 1 0 Zone 2 G Zone 3 0 Zone 4 FIXT Zone Table C405.5.2(1) Specified by jurisdiction. Zone selection required to enable LTG -EXT form Calculation Area 0 0 Addition- 0 Addition 18 stand alone + exist ng 36 v 0 Alteration with < 50% Alteration with >_ 50% ext. C) CD ext. wattage replaced wattage replaced WITH 0-10V DIMMING DRIVER. Building Grounds 0 Efficacy> 80 lumens/watt 0 Exemption Applies to luminaires > 100 Watts 0 Controlled by motion sensor Tradable Maximum Allowed Lighting g Watta a NOTE1 Base Site Allowance: 750 LED Area (ft), perimeter Allowed Wafts Allowed Wafts Tradable Surfaces Surface Description (if) or # of items per fe or per If x fig (or x 10 Other Entry Door DOOR AT GARAGE 6 20W/LF door 120 28 F3 RECESSED SHOWER LIGHT WITH 6" APERTURE WITH WHITE TRIM LED 39 Tradable Surface Fixture Description NOTE 3.4 Number of Watts per Fixtures Fixture NOTE 5 Watts Proposed Other Entry Door FE1-ENTRY DOOR LIGHT LED 1 18 18 DESCRIPTION LAMP FIXT €NTEMOR Total proposed tradable Kiatts may not exceed the sum of total alloved tradable unffc nhic thn haco cite nllnunnra Anil haco cito nllrnnanrn not nacrlor! to Total Proposed Tradable Watts 18 Non -Tradable Maximum Allowed Lighting Wattage ""' Site Allowance Remaining: 750 Non -Tradable Surfaces Surface Description Area (), perimeter Allowed Watts Allowed Watts (If) or # of items per fe or per If x f? (or x 10 i WATMI TYPE DESCRIPTION LAMP FIXT €NTEMOR Number of Watts per Watts Non -Tradable Surface Fixture Description NOTE 3.4 Fixtures Fixture NOTE 5 Proposed LIGHTING FIXTURE SCHEDULE I i i I i I i I \0\ i WATMI TYPE DESCRIPTION LAMP FIXT €NTEMOR F1 RECESSED 2x4 DIRECT/INDIRECT TROFFER, NOMINALLY Z x 4' x 4" LED 36 v WITH EXTRUDED ACRYLIC LENS. 3500K, 80 CRI, 3900 LUMEN C) CD I- WITH 0-10V DIMMING DRIVER. LO JUNO LIGHTING S2X4BL-39-35-U WH3 FIX SIMILAR TO F1 EXCEPT WITH INTEGRAL EMERGENCY BACK UP BALLAST. LED 36 JUNO LIGHTING S2X4BL-39-35-U-WH3-BR F2 NOT USED. LED 28 F3 RECESSED SHOWER LIGHT WITH 6" APERTURE WITH WHITE TRIM LED 39 AND DROPPED GLASS LENS. DEAD FRONT TRIM. U 30 LUMENS PER WATT MINIMUM WITH 1164 DELIVERED LUMENS. HE WILLIAMS LEDPSL60 W F4 WALL MOUNTED, NOMINAL 28"x 3"x 4' VANITY LIGHT, WHITE ACRYLIC LED 13 DIFFUSER WITH METAL END CAPS IN MANUFACTURER'S STANDARD FINISH AS SELECTED BY ARCHITECT. CENTER BETWEEN CEILING f— AND MIRROR. CENTER HORIZONTALLY WITH MIRROR � COORDINATE PRIOR TO ROUGH -IN. WHITE 30K LEDS. 82. IU) LUMENS PER WATT (U a OXYGEN APOLLO 3-5104-14 I� U�< I F5 PENDANT MOUNTED DECORATIVE LED WITH 0-10V DIMMING DRIVER- LED 78 VIBIA HALO 2332 SERIES. F- F6 SURFACE PENDANT MOUNTED LED RING LIGHT, DIAMETERS AS SHOWN ON LED 17 w;� 0'W PROJECT DOCUMENTS. REMOTE 20OW DRIVER FOR 12 AND 11' DIAMETER W PENDANTS AND 10OW DIMMING DRIVER FOR 10' DIAMETER. U > ART LIGHT RING SERIES m F7 RECESSED 2x4 LED TROFFER WITH ACRYLIC LENS AND WHITE LED 25 Vf STEEL HOUSING, 35K, 3000. LUMENS WITH 0-10V DIMMING DRIVER - 111 Z) Of U) VIA OCCUPANCY SENSOR TURNS FIXTURE TO 50 PERCENT POWER W Q LITHONIA 2TLT SERIES 0II— F7X SIMILAR TO F7 EXCEPT WITH 700 LUMEN BATTERY PACK LED 25 F8 SURFACE MOUNTED LOW PROFILE WRAP, LED, NOMINALLY LED 40 4'x 2-25"x 3" WITH ACRYLIC LENS. MOUNT AT 9'-0" AFF = i o U!p STANDARD OUTPUT o O W PRUDENTIAL SNAP S1-lT5-04YGWSERIES U) i u7 AXIS MBS SERIES Lo i 0- I ARCHITECTURAL LIGHTING WORKS TRIPLANE SERIES O F9 RECESSED 6" LED DOWNLIGHT WITH SELF FLANGED MATT LED 28 DIFFUSE REFLECTOR AND 1800 LUMENS MINIMUM AND WITH Z MEDIUM DISTRIBUTION 3500K COLOR TEMPERATURE WITH 80 CRI MINIMUM. 0-10V DIMMING DRIVER. i i(o GOTHAM 35186ARMDMDLD SERIES IC) HE WILLIAMS LED60PH2O835 SERIES W I— �i� O O N.N PATHWAY 6VLBV2035KM SERIES NiN �:� PORTFOLIO LD6A20 SERIES Q F9X SIMILAR TO F9 EXCEPT WITH 500 LUMEN BATTERY PACK LED 28 F10 PENDANT LOW VOLTAGE LiNEAR 6' LINEAR LED NOMINALLY 4" WIDE BY LED �i00 I 4' LONG WITH 0-10V DIMMING DRIVER 40W REMOTE DRIVER. CD! CONNECT TO MINI EMERGENCY INVERTER. LIGHT ART CASPER SERIES XI EXIT SIGN WITH INTEGRAL BATTERY PACK GREEN STENCIL FACE LED 5 AND WHITE POLYCARBONATE HOUSING. UNIVERSAL MOUNTING HARDWARE. HE WILLIAMS EXIT G -EM SERIES. EXTEPJOR FE1 WALL MOUNTED LED CYLINDER, NOMINALLY LED 18 12" HIGH BY 6" DIAMETER, EXTRUDED ALUMINUM_ HOUSING. SEE ARCHITECTURAL PLANS FOR MOUNTING LOCATION. LUMINAIRE, WHITE 42K LED 65 LUMENS PER WATT. SISTEMALUX MIN€SLOT SERIES LIGMAN TANGO ROUND SERIES OMEGA OM6LED SERIES FE1X SIMILAR TO FE7 WITH REMOTELY MOUNTED LED 18 MINI INVERTER. JACKSON I MAIN ARCHITECTURE 311 FIRST AVENUE SOUTH SEATTLE, WA 98104 t 206.324.4800 WWW.JACKSONMAIN.COM 19515 North Creek Parkway, Suite 302 Bothell, Washington 98011 Phone: 425-402-9400 Fax: 425-402-9402 Z I i i I i I i I \0\ i m00 i CK 00 Wrn Z LLQ r< F'- J o v U C) CD I- N LO Z I i i I i I i I i i O i U U W F— W i U) f— � Z IU) (U a I� U�< I C) F- w;� 0'W W W U > >>LLI m Vf W 0 111 Z) Of U) W Q Z 0II— WiC2C9U� = i o U!p U) W o O W U) i u7 0 Lo i 0- I O �iN M �Iu7 Z i i(o r.0 IC) W I— �i� O O N.N N O NiN �:� Q coOp �ic- N C); i .-- �i00 I Co CD! E!/IEUVED.FOR DPLIANCE .WITH NFPA 70 v NEC r i DEC 0 9 2016 1 City of-Tcvila ` UiLDING DIVISION PROJECT NO.: PROJECT MGR.: DRAWN BY: CHECKED BY: 16040/C16163 LM CJP MSC LIGHTING FIXTURE SCHEDULE i 5 3 JACKSON I MAIN ARCHITECTURE P.S. © 2015 z • I COMMUNICATIONSLEVEL I POWER & 1 " ew .a L0 N 0 N O GENERAL NOTES 1. ALL RECEPTACLES IN THIS FACILITY SHALL BE TAMPER RESISTANT UNLESS NOTED OTHERWISE. SEE ELECTRICAL SYMBOLS LEGEND, SHEET E0.01, FOR ADDITIONAL INFORMATION. 2. PROVIDE ALL CONDUIT, BOXES AND WIRE AS REQUIRED BY WAC, NEC, AND SPECIFICATIONS FOR A FULLY FUNCTIONING SYSTEM. 3. COORDINATE ALL CEILING MOUNTED DEVICE LOCATIONS WITH ARCHITECTURAL REFLECTED CEILING PLANS. WHERE CONFLICT OCCURS, ARCHITECTURAL R.C.P. TAKES PRECEDENCE EXCEPT WHEN LOCATION IS MODIFIED BY CODE AUTHORITY. 4. WALL MOUNTED DEVICES SHALL NOT BE MOUNTED BACK TO BACK UNLESS PHYSICAL SPACE NECESSITATES IT. IF THESE DEVICES MUST BE MOUNTED BACK TO BACK, PROVIDE SOUND INSULATION AT BOXES. 5. FOR BRANCH CIRCUITS THAT EXCEED 75 FEET IN LENGTH, INCREASE WIRE BY ONE WIRE SIZE. 6. HOMERUNS SHALL NOT BE COMBINED. 7. PROVIDE DEDICATED NEUTRAL CONDUCTOR FOR EACH BRANCH CIRCUIT. 8. SEE ARCHITECTURAL ELEVATIONS FOR MOUNTING HEIGHTS OF ALL DEVICE LOCATIONS, UNLESS NOTED OTHERWISE. SEE ARCHITECTURAL CASEWORK ELEVATIONS AND DETAILS FOR EXACT MOUNTING HEIGHTS. _ RECEI� 0 CITY Y CF TUKV-ILA NOV 212016 PERMIT CENTER JACKSON I MAIN NRCHITECTURE 311 FIRST AVENUE SOUTH SEATTLE, WA 98104 t 206.324.4800 WWW.JACKSONMAIN.COM z I i I i z J m D0 I W �-- W 00 o0 �p z00 U� w Cn < = �w �Q —U Oma_ LL U O N Z) L I -- z I i I i I i o I U � U W {- W ' i LU j U F- U) i z iW z i H W F- W �U) :>: WJ U CL O u5!� wj Q W U > > >im W W WIC of! U) i0 z Q) oih_ C)i� W 2 o U o iW' U o W ojuJ UcooLla O N M VILo z ! (D (D co co W F- Flo NiN 0 N 0;o �iQ i o � •-ice (o N Q`� i x:00 ti l 00 i 00 !�! r DEC 0 9 2016 City of Tukvvila PROJECT NO.: 16040/C16163 PROJECT MGR.: LM DRAWN BY: CJP CHECKED BY: MSC LEVEL 1 POWER & COMMUNICATIONS PLAN JACKSON I MAIN ARCHITECTURE P.S. ©2015 • ■ POWERLEVEL 2 COMMUNICATIONS PLAN SCALE: 1/8" = 1'-0" 0 GENERAL NOTES 1. ALL RECEPTACLES IN THIS FACILITY SHALL BE TAMPER RESISTANT UNLESS NOTED OTHERWISE. SEE ELECTRICAL SYMBOLS LEGEND, SHEET E0.01, FOR ADDITIONAL INFORMATION. 2. PROVIDE ALL CONDUIT, BOXES AND WIRE AS REQUIRED BY WAC, NEC, AND SPECIFICATIONS FOR A FULLY FUNCTIONING SYSTEM. 3. COORDINATE ALL CEILING MOUNTED DEVICE LOCATIONS WITH ARCHITECTURAL REFLECTED CEILING PLANS. WHERE CONFLICT OCCURS, ARCHITECTURAL R.C.P. TAKES PRECEDENCE EXCEPT WHEN LOCATION IS MODIFIED BY CODE AUTHORITY. 4. WALL MOUNTED DEVICES SHALL NOT BE MOUNTED BACK TO BACK UNLESS PHYSICAL SPACE NECESSITATES IT. IF THESE DEVICES MUST BE MOUNTED BACK TO BACK, PROVIDE SOUND INSULATION AT BOXES. 5. FOR BRANCH CIRCUITS THAT EXCEED 75 FEET IN LENGTH, INCREASE WIRE BY ONE WIRE SIZE. 6. HOMERUNS SHALL NOT BE COMBINED. 7. PROVIDE DEDICATED NEUTRAL CONDUCTOR FOR EACH BRANCH CIRCUIT. 8. SEE ARCHITECTURAL ELEVATIONS FOR MOUNTING HEIGHTS OF ALL DEVICE LOCATIONS, UNLESS NOTED OTHERWISE. SEE ARCHITECTURAL CASEWORK ELEVATIONS AND DETAILS FOR EXACT MOUNTING HEIGHTS. FLAG NOTES [�> RELOCATE EXISTING FURNITURE FEED TO NEW LOCATION. CITY OF TUKWiLA NOV 212016 PERMIT CENTER JACKSON I MAIN NRCHITECTURE 311 FIRST AVENUE SOUTH SEATTLE, WA 98104 t 206.324.4800 WWW.JACKSONMAIN.COM CASE ENGINEERING Consulting Electrical Engineers 19515 North Creek Parkway, Suite 302 Bothell, Washington 98011 Phone: 425-402-9400 Fax: 425-402-9402 i.w to 0 ! i ! ! I Z m J 00 tt m co W W 000 00 �0 z� z� C) 0 w a__ _ <C � cf) J a _ U O� -� OEM= O LL O o N L(rq) �-- i.w to Z ! i ! ! I Z m 00 �00 W W 00 �0 z� C) 0 w a__ �W �Q _ U O -� z LL O o L(rq) �-- Z ! i ! ! I O a__ U U ! i W 1Uj i I UJ U F- '•.� U! f- Z'w Z W F- ! S I U 2 A W: -J U) olwW w� v'> > >im W Q m W 0 WD IX U WIo (D UIQ =o cnoi� U p W o1W UiC0 0 U-) !Z O ! .-IN m vLn I 'o 'o ( (0 (0 w r ro!0E CD 0 00 H N!N 00 Oi� NQ O NN x'10 r 1 0 O C=)r i REVIEWED FOR N FPA 70 - NEC N DEC 09 2016 City 01 T6WI a PROJECT NO.: 16040 / C16163 PROJECT MGR.: LM DRAWN BY: CJP CHECKED BY: MSC mm LEVEL 2 POWER& COMMUNICATIONS PLAN JACKSON I MAIN ARCHITECTURE P.S. © 2015 LO N O O N O O JACKSON ( MAIN ARCHITECTURE 19515 North Creek Parkway, Suite 302 Bothell, Washington 98011 Phone: 425-402-9400 Fax: 425-402-9402 Z I PROJECT MGR.: I I I i 1 DRAWN BY: i j ! CHECKED BY: MSC O ! i a U i j ! W ! W U) Z Z W I W m W cn 2 Q- W. cn H WI C) W Wim U;>> >m i W W W.Z i �!of p 0 !cn alp W p Z L9 p!:l-- 01:E i m � UI'O m W W p W co CD p LO, a Z i i W.- �- O j 0 O N N 1 i v- (0 1 i r N Q CDr � p.co rIO 00 O O�r- .- i i REWEWEDFOR COMPLIANCE WITH ` NFPA70-NE f DEC o 9 L� is City offukWla PROJECT NO.: 16040 / C16163 PROJECT MGR.: LM DRAWN BY: UP CHECKED BY: MSC ROOF POWER & COMMUNICATIONS PLAN JACKSON I MAIN ARCHITECTURE P.S. © 2015 I ,. ■ PARKING LEVEL LIGHTING PLAN a 0" ( REC.E'I ea0 CITY Y OF T UKVifiL NOV 212016 PER -1101T CENTER 19515 North Creek Parkway, Suite 302 Bothell, Washington 98011 Phone: 425-402-9400 Fax: 425-402-9402 z i I' I I O i j O D Z J m pO woo i W 00 ry Up p zo W0-) U) Q = Q D W �Q —U Oma_ i I HN O 0 � i Lo - Icmmm i LU Z i I' I I i j O i � I � I U i I i i LU i W; U) F- U); U). z:: Z F -W Z UJ FiU) Ur ,W :E LU fn � �IF¢- �I Wi� O0 �w W WIC U> > >m W Him W LU D rn Z pil— U-I 0 C W pial rico o L01� O Z N M 'IT LO +� (0I(o W H 0 NiN o N Oi0 NIN Q Q co a--ia- 1,00 rD rD N '. O CDj� i REVIEWED .FOR COMPLIANCE WITH NFPA 70 - NEC DEC 0 9 2016 City of•Tukuvila JACKSON I MAIN ARCHITECTURE P.S. © 2015 I LEVEL 1 LIGHTING FLOOR PLAN SCALE: 1/8" = 1'-0" CL ui v, N O O N O RECEIVE -10 CITY OF t UKV, DLA NOV 212016 PERMIT CENTER JACKSON I MAIN ARCHITECTURE 311 FIRST AVENUE SOUTH SEATTLE, WA 98104 t 206.324.4800 WWW.JACKSONMAIN.COM 19515 North Creek Parkway, Suite 302 Bothell, Washington 98011 Phone: 425-402-9400 Fax: 425-402-9402 rI D � i � \i\ U)J00 � � I i I I I I m 00 00W z Q 0 SEEM W� cz U cl) Q 0 00 Effam C:) 0 ~ (N L0 rI D � i � r) � � I i I I I I Z m 0 ry W 00 00 00 W ct W DQ -U O� � LL U) U) z0 LL 0 �N se I- z � i � � � I i I I I I I f I I i I 0 a_ U U) W j W ' F- W ; � F- I I � cnj Z W I U) I Z F- F— LU �iW W'_1 iV7 LU d [njQ � I F- 0 W W W!� U » W W 5 E W QIP 0 Of U) 0 Z 0 1- W 2o rn o U o W b: Lu U) co 0 ,n IZ i Oc-N M d'IL Z I i I I� --:- I ! W o 0 0 N 04 N I i c 1 Q I 0 1 N O \ NIco i co r I ! REVIEWED .FOR PLIANCE WITH NPPA 70 - NEC DEC 0 9 2016 City of 11a BUILDING DIVISION ` PROJECT NO.: 16040 / C16163 PROJECT MGR.: LM DRAWN BY: CJP CHECKED BY: MSC LEVEL 1 LIGHTING FLOOR PLAN 3 1 JACKSON I MAIN ARCHITECTURE P.S. © 2015 \ I r NORTH LEVEL 2 LIGHTING FLOOR PLAN SCALE: 1/8" = V-0" 19515 North Creek Parkway, Suite 302 Bothell, Washington 98011 Phone: 425-402-9400 Fax: 425-402-9402 z i j j ` \) Jclo m i W 00 00 z>�> D W> r) =Q Z J m � J O1 W U) D C:) O I- z00 w CV z i j j ` _O i o D r) Z J m �0 �00 W �-- L00 � U0 0 z00 w TZ D< W ::)Q - CJ OLL J U) z LL 0 N ��2 w p j w w z i j j ` i o j cf) w p j w w U) �i W; 1.-1-- U-1 Z I Z j f— w 1— W Wim < U d U) U) O j W p;.—. W ...;� UjW W WIC'^ LILY p �jyJ Z p l— wjp CD U� U p W p;W rn '0 p Ln ; d o N 0 'IT U-) Z j j (DCDt(0 j w 0 0 0 0 0 C-4 N N N aN I-- 0o co r REVIEWED FOR pMPLI 7®C NECT� NEPA DEC 0 9 2016 F Y_ fE 3 Y U C I 0 Q 0 0 'c 0 U 0 V O v O C: m U 0 0 U) Y (0 Y U N L m LO N co r O _ N O Lis, JACKSON I MAIN ARCHITECTURE 311 FIRST AVENUE SOUTH SEATTLE, WA 98104 t 206.324.4800 WWW.JACKSONMAIN.COM CASE ENGINEERING Consulting Electrical Engineers 19515 North Creek Parkway, Suite 302 Bothell, Washington 98011 Phone: 425-402-9400 Fax: 425-402-9402 z j j DRAWN BY: i i j m CO00 a w Z a, WCl)� � J 0 v U) D mmum 0 O i— N W�-- z j j DRAWN BY: i i j 0 j i j j z o z J [ri W W�-- � OO Co r= a z00 w U� C) Q = D W DQ U 0J_ 0—U) U) LL 0 N F— ' � W W j z j j DRAWN BY: i i j CHECKED BY: j i j j O a U I ' W W j I U LUF-U) z W W jU Zig C7iCW a N Q Lij W W W W j Wi= Q�0z 0 11 iU c� p W z p'';H C -) ' W U) Uj(D o L d i O z �iN M d L i i to W -ice O 1 O - O N I— Q C" C14 00o� '; N i N �iO pp r• O N 1:00 i`10 00 O O PROJECT NO.: 16040/C16163 PROJECT MGR.: LM DRAWN BY: CJP CHECKED BY: MSC PARKING LEVEL MECHANICAL POWER PLAN J JACKSON I MAIN ARCHITECTURE P.S. © 2015 U) Y ca Y U ) C 0 Q 0 U 2 .Q U) 0 �r 0 0 E U O 0 N Y cu Y U (D cn Z) A NORTH LEVEL 1 MECHANICAL POWER PLAN SCALE: 1/8" = 1'-0" ew GENERAL NOTES 1. ALL RECEPTACLES IN THIS FACILITY SHALL BE TAMPER RESISTANT UNLESS NOTED OTHERWISE. SEE ELECTRICAL SYMBOLS LEGEND, SHEET EO.01, FOR ADDITIONAL INFORMATION. 2. PROVIDE ALL CONDUIT, BOXES AND WIRE AS REQUIRED BY WAC, NEC, AND SPECIFICATIONS FOR A FULLY FUNCTIONING SYSTEM. 3. COORDINATE ALL CEILING MOUNTED DEVICE LOCATIONS WITH ARCHITECTURAL REFLECTED CEILING PLANS. WHERE CONFLICT OCCURS, ARCHITECTURAL R.C.P. TAKES PRECEDENCE EXCEPT WHEN LOCATION IS MODIFIED BY CODE AUTHORITY. 4. WALL MOUNTED DEVICES SHALL NOT BE MOUNTED BACK TO BACK UNLESS PHYSICAL SPACE NECESSITATES IT. IF THESE DEVICES MUST BE MOUNTED BACK TO BACK, PROVIDE SOUND. INSULATION AT BOXES. 5. FOR BRANCH CIRCUITS THAT EXCEED 75 FEET IN LENGTH, INCREASE WIRE BY ONE WIRE SIZE. 6. HOMERUNS SHALL NOT BE COMBINED. 7. PROVIDE DEDICATED NEUTRAL CONDUCTOR FOR EACH BRANCH CIRCUIT. 8. SEE ARCHITECTURAL ELEVATIONS FOR MOUNTING HEIGHTS OF ALL DEVICE LOCATIONS, UNLESS NOTED OTHERWISE. SEE ARCHITECTURAL CASEWORK ELEVATIONS AND DETAILS FOR EXACT MOUNTING HEIGHTS. . Cff Y 0I T U MALA NOV 2 12016 PER -UHT CENTER J/ 4I C) 1! Phc �CKSON I MAIN ZCHITEC TURE 11 FIRST AVEK-3 It= SOUTH SEATTLE, VIS 98104 t 206.324490() VVVW.JACKS0"..,o\ I N.COM CNSE ENCI EERING insulting Electrt I Engineers )515 North Creek Nhway, Suite 302 Bothell, Washing= 98011 ne: 425-402-9400 Fax = 425-402-9402 z I I ! I I O ! I i i i —� CO l 06 j rnW V/ l � J 0- W °D V `t LU Z � cin -p oo U� w0-) r0 m cf) p I -- WU O Ly CN Oma_ LO LL z I I ! I I O ! I i i i Z ! j J 0- O °D W _ 1-- LU 00 o0 � Z oo U� w0-) U ! D� WU Ly Oma_ 0- LL LU O O N LO F -- w REVIEWED FOR COMPLIANCE WITH MFPA70-NEC DEC 0 9 2016 (mm I I ! I I ! I i i i o ! 0- � I U ! U) LU w c i wI U)z j w rn I �.w�i ZiW 2 LU 2Iw a (IQ w i�OJ3I= Diw W Wil U i>> >im W w LU r7iF— wI� U Uig 01 c) W o W ! U;(.0 D N!Z O N Ch d L Z I i_ W C=) c) N!N 0 NNN O o �:� i Q C) !'2 Z_ to Npi_ O� � iZ_ co00 I I i REVIEWED FOR COMPLIANCE WITH MFPA70-NEC DEC 0 9 2016 (mm A a v LO v N Cfl 0 N O LEVEL 2 MECHANICAL POWER PLAN SCALE: 1/8" = 1'-0" GENERAL NOTES 1. ALL RECEPTACLES IN THIS FACILITY SHALL BE TAMPER RESISTANT UNLESS NOTED OTHERWISE. SEE ELECTRICAL SYMBOLS LEGEND, SHEET EO.01, FOR ADDITIONAL INFORMATION. 2. PROVIDE ALL CONDUIT, BOXES AND WIRE AS REQUIRED BY WAC, NEC, AND SPECIFICATIONS FOR A FULLY FUNCTIONING SYSTEM. 3. COORDINATE ALL CEILING MOUNTED DEVICE LOCATIONS WITH ARCHITECTURAL REFLECTED CEILING PLANS. WHERE CONFLICT OCCURS, ARCHITECTURAL R.C.P. TAKES PRECEDENCE EXCEPT WHEN LOCATION IS MODIFIED BY CODE AUTHORITY. 4. WALL MOUNTED DEVICES SHALL NOT BE MOUNTED BACK TO BACK UNLESS PHYSICAL SPACE NECESSITATES IT. IF THESE DEVICES MUST BE MOUNTED BACK TO BACK, PROVIDE SOUND INSULATION AT BOXES. 5. FOR BRANCH CIRCUITS THAT EXCEED 75 FEET IN LENGTH, INCREASE WIRE BY ONE WIRE SIZE. 6. HOMERUNS SHALL NOT BE COMBINED. 7. PROVIDE DEDICATED NEUTRAL CONDUCTOR FOR EACH BRANCH CIRCUIT. 8. SEE ARCHITECTURAL ELEVATIONS FOR MOUNTING HEIGHTS OF ALL DEVICE LOCATIONS, UNLESS NOTED OTHERWISE. SEE ARCHITECTURAL CASEWORK ELEVATIONS AND DETAILS FOR EXACT MOUNTING HEIGHTS. CITY Ci� "<� K01 NOV 212016 PERMIT CENTER JACKSON I MAIN N R C H I T E C T U R E 311 FIRST AVENUE SOUTH SEATTLE, WA 98104 t 206.324.4800 WWW.JACKSONMAIN.COM Consulting Electrical Engineers 19515 North Creek Parkway, Suite 302 Bothell, Washington 98011 Phone: 425-402-9400 Fax: 425-402-9402 0 J m 00 r LU 13 z Q w� r Q J_ O v D O F- CD N LO z I i I i i i I I I I _O i I I z I Zm O 10� CL � 00 Oo �p -)w z00 (� r Q z ! �W I DQ _ U O -� CnUi LI_ O I � F -- I •. z I i I i i i I I I I i I I o I CL � ! I CnUi I I •. LU I ~' W ; Cn t - I-- U) U) Z i LLI I Zig W (D WIJ ; U) U d Go< U), 0_0!W0: 0!W J W W� Uig i >;m IW W UJ Z) a`U Z 0'H W':0 U!o W 01 LU C/)to U mid OiCV M V'iln Z i Co W o 0 0 o i 0 F- N N N 04 04 (.0 Oi� C 1-00 00 C)�� REVIEWED FCR i COMPLIANCE WITH NFPA 70 a NEC DEC 9 9 2016 cfty ofTlnla_ Tukwila ­ PROJECT PROJECT NO.: 16040 / C16163 PROJECT MGR.: LM DRAWN BY: CJP CHECKED BY: MSC LEVEL 2 MECHANICAL POWER PLAN 3 I I JACKSON I MAIN ARCHITECTURE P.S. ©2015 A JACKSON I MAIN ARCH I T E C T U R E 311 FIRST AVENUE SOUTH SEATTLE, WA 98104 t 206.324.4800 WWW.JACKSONMAIN.COM 19515 North Creek Parkway, Suite 302 Bothell, Washington 98011 Phone: 425-402-9400 Fax: 425-402-9402 z 16040 / C16163 PROJECT MGR.: LM DRAWN BY: CO 1z ry 06 co W "t Z (3) < om Now W C) r 0 (1) D so= c) O I- (N LO z 16040 / C16163 PROJECT MGR.: LM DRAWN BY: Cip CHECKED BY: msc 0 IL C) cf) LU LU LU U) I-- F- U) z LU U) z LU LU LU LD U) 0 U) U) LU 0 0;111 LU 1-11 );> > dim U -I LU LU Z) [if I U) zF- (D Uig i LU Fn 6-, c) : 0 0 Lu 0 i LU cf) (0 (c) CL c; z N c) Vit-) (D (o 0 0 0 Li L C:) 0 C) Qp co (D 'T co C'4 r— 00 'o PROJECT NO.: 16040 / C16163 PROJECT MGR.: LM DRAWN BY: Cip CHECKED BY: msc ROOF MECHANICAL POWER PLAN 0 JACKSON I MAIN ARCHITECTURE P.S.@2015 C-1 ;r. E`0.E'I9lz'0 CITY OF TUKWILA. NOV 212016 RERPAIT CENTER v ACKSON I MAIN RCHITECTURE 311 FIRST AVENUE SOUTH SEATTLE, WA 98104 t 206.324.4800 WWW.JACKSONMAIN.COM 19515 North Creek Parkway, Suite 302 Bothell, Washington 98011 hone: 425-402-9400 Fax: 425-402-9402 z PANEL'P2A' PANEL'P1A' SEC. 2 SEC.1 i I I PROJECT NAME INSPIRUS TUKWILA PROJECT NAME INSPIRUS TUKWILA PROJECT NAME INSPIRUS TUKWILA PROJECT#: 16163 PROJECT#: 16163 LOCATION: 1ST FLOOR OPEN OFFICE FED FROM: FED FROM: PIA SEC 1 FED FROM: PANEL HA FED FROM: PANEL HA 1200A BUSSED GUTTER NOTE CKT CIRCUIT NAME NO. NOTE CKT NO. CIRCUIT NAME CB SIZE 0 AMPI 0 LOAD(KVA) PANEL DESCRIPTION 43 BS -201, BS -202 + FCUs PANEL DESCRIPTION PI R I H M L K 0 TOTAL 43 VVI+l A 30 131 1 2.0 I 12.0 45 - B PANEL AMPS: 200 45 - B - - 2.0 47 BS -203, BS -204, BS -205 + FCUS 2.0 FEEDER AMPS : 200 47 - C - - 2.0 A 2.0 L- L VOLTS : 208 49 BS -101, BS -102 + FCUS A 20 2 i 1.3 1.3 L- N VOLTS: 120 51 - B - C - 1.3 1.3 PHASE: 3 53 BS -103, BS -104 + FCUs C 20 2 -1 1.2 1.2 WIRE: 4 55 - A - - - 1.2 1.2 0.8 0.8 57 ERV -101 - ERV -105 B 20 3 20 1.1 1.1 1.4 FLUSH 59 - C - - 20 1.1 1.1 M.L.O. X X 61 - A - - 1 1.1 1.1 MAIN CB SURFACE W 63 CP -1 B 20 1 0.2 29 0.2 FLUSH X X 65 SPARE C 20 1 1 0.5 31 SPA RE SURFACE SURFACE 73 SPACE A - 1 67 SPARE A 20 1 1 0.5 33 SPARE ISO GND 77 SPACE C 69 SPARE B 20 1 20 1 0.7 79 SPACE FEED•THRU - 1 71 SPARE C 20 1 81 SPACE B - 1 20 73 SPARE A 20 1 75 SPA RE B 20 1 39 SPA RE B REC KVA 35 77 SPARE C 20 1 41 SPARE C HEAT KVA 37 79 SPARE A 20 1 6.3 2 FURN FEED - EXEC OFFICE A 20 1 1 1 0.6 0.6 MOTOR KVA : LIGHTING KVA LOADSUMMARY 50 ISPARE Al20111 81 SPARE B 20 1 0.6 HEAT KVA KITCHEN KVA ( TOTAL, ALL SECTIONS) 83 SPARE C 2011 LIGHTING - PARKING GARAGE ! 0.3 OTHER KVA : REC KVA 56 SPARE 44 REC- GYM EQUIPMENT A 20 1 i 1.2 1 1.2 46 REC- GYM EQUIPMENT B 20 11 1.2 58 SPARE 1.2 HEAT KVA : 6.0 48 REC- GYM EQUIPMENT C 20 11 1.2 C 1.2 MOTOR KVA : LIGHTING KVA 14.6 50 REC- GYM EQUIPMENT A 20 1 1.2 1.2 52 REC- GYM EQUIPMENT B 20 1 1.2 10 1.2 KITCHEN KVA FHASEBKVA : 54 RBC- GYM EQUIPMENT C 20 1 1.2 12 1.2 OTHER KVA : 8.3 56 REC- GYM EQUIPMENT A 20 1 1.2 14 1.2 3.1 26.2 68 SPACE A - 1 58 REC- GYM EQUIPMENT B 20 1 1.2 16 1.2 PHASEA KVA : 10.4 60 REC- GYM EQUIPMENT C 20 1 1.2 18 1.2 AMPS : 86.8 62 REC- GYM EQUIPMENT A 20 1 1.2 10.6 1.2 R-ASEB KVA : 9.4 64 REC- GYM EQUIPMENT B 20 1 1.2 80 SPACE 1.2 AMPS : 78.2 66 REC- GYM EQUIPMENT C 20 1 1.2 B 1.2 PHASEC KVA : 9.1 68 SPARE A 20 1 C - 1 A MPS : 76.1 70 SPARE B 20 1 169.8 DEMAND/ DIVERSITY FACTORS LOAD DESCRIPTION R RECEPTACLES- TO 10KVA REMAINING OVER 10KVA H HEATING M MOTORS LM LARGEST MOTOR L LIGHTING K KITCHEN 0 OTHER REC - RECEPTION, DEMO ROOM DEMAND 100% _ 50% _ 100% _ 100% _ 125% _ 125% _ 65% _ 100% = 10.6 72 SPARE C 20 1 30 LTS-1ST FLR C 20 74 SPACEONLY A 1.9 32 LTS-1ST FLR CONNECTED LOAD 76 SPACEONLY B A 1.9 CONNECTED LOAD 34 LTS-lSTFLR KVA : 28.9 78 SPACEONLY C 1.9 KVA : 62.0 36 LTS-lSTFLR AMPS : 80.3 80 SPACEONLY A 1.9 AMPS: 172.2 38 SPARE DEMAND LOAD. 20 82 ISPACEONLY B 108.3 DEMAND LOA D 40 SPARE KVA : 29.2 84 ISPACEONLY C KVA : 63.9 42 SPARE AMPS: 81.1 NOTES/REMARKS: 1. 2. 3. DEMAND/ DIVERSITY FACTORS AMPS : 177.5 NOTES/REMARKS : 1. 2. 3. LOAD DESCRIPTION DEMAND R RECEPTACLES - TO 1 OKVA 100% _ REMAINING OVER 10KVA 50% _ H HEATING 100% = M MOTORS 100% = LM LARGEST MOTOR 125% = L LIGHTING 125% _ K KITCHEN 65% _ 0 OTHER 100% = 6.0 13.4 1.5 8.3 E`0.E'I9lz'0 CITY OF TUKWILA. NOV 212016 RERPAIT CENTER v ACKSON I MAIN RCHITECTURE 311 FIRST AVENUE SOUTH SEATTLE, WA 98104 t 206.324.4800 WWW.JACKSONMAIN.COM 19515 North Creek Parkway, Suite 302 Bothell, Washington 98011 hone: 425-402-9400 Fax: 425-402-9402 z PANEL'P2A' SEC. 2 PANEL'HA' SEC.1 i I I PROJECT NAME INSPIRUS TUKWILA z PROJECT NAME INSPIRUS TUKWILA PROJECT#: 16163 LOCATION: 1ST FLOOR OPEN OFFICE PROJECT#: 16163 FED FROM: P2A SEC 1 FED FROM: PANEL HA FED FROM: PANEL HA 1200A BUSSED GUTTER NOTE CKT CIRCUIT NAME NO. NOTE CKT CIRCUIT NAME NO. CB SIZE 8 AM P R I LOAD (KVA) H M L K 0 TOTAL PANEL DESCRIPTION 43 BS -201, BS -202 + FCUs Al20 1 121 A 1.6 1.6 PANEL AMPS : 200 45 - B - 1-1 REC - MEDIUM CONFERENCE ROOM, TV 1.6 1.6 FEEDER AMPS : 200 47 BS -203, BS -204, BS -205 + FCUS C 20 2 5 1.2 1.2 11 L - L VOLTS : 208 49 - A - 1-1 208 1.2 1.2 L- N VOLTS : 120 51 ERV -201 - ERV -205 B 20 3 L- N VOLTS: 1.1 1.1 PHASE: 3 53 - C - 1-1 1.2 1.1 1.1 WIRE: 4 55 - A - -1 1.2 1.1 1.1 4 13 57 FCU -242 B 20 21 0.8 0.8 59 - C - -1 1.2 0.8 0.8 M.L.O. X FURN FEED - OPEN OFFICE 154 61 SPARE A 20 1 1.2 1.4 FLUSH MAIN CB 17 FURN FEED- OPEN OFFICE 154 63 SPARE B 20 11 1FLUSH 1.2 ML.O. X X 19 65 SPARE C 20 1 SPARE B 0.7 SURFACE W W co 67 SPACE TI_- B 11 1 0.5 29 SPARE ISO GND FEED-THRU FLUSH X 69 SPACE B - 1 71 SPACE C - 1 1 0.5 31 SPA RE 0.5 SURFACE 73 SPACE A - 1 75 SPACE B - 1 20 1 0.5 33 SPARE 0.5 77 SPACE C - 1 29 REC- OFFICE 161, CONF 162 C 20 1 0.7 79 SPACE A - 1 0.4 90.5 31 SPARE LOADSUMMARY 20 81 SPACE B - 1 20 1 33 ( TOTAL, ALL SECTIONS) 83 SPACE C - 1 39 SPA RE B REC KVA 35 44 SPARE A 20 1 46 1 SPARE B 20 Ill 41 SPARE C HEAT KVA 37 48 ISPARE C 20111 1 REC KVA : 6.3 2 FURN FEED - EXEC OFFICE A 20 1 1 1 0.6 0.6 MOTOR KVA : LIGHTING KVA FURN FEED - EXEC OFFICE 50 ISPARE Al20111 52 SPARE B 20 1 A 0.6 HEAT KVA KITCHEN KVA 41 54 SPARE C 20 1 LIGHTING - PARKING GARAGE B 0.3 OTHER KVA : 10.6 56 SPARE A 20 1 20 1 0.9 C 2011 0.9 58 SPARE B 20 1 C 20 1 PHASEA KVA : 3.9 60 SPARE C 20 1 FURN FEED- ISA OFFICE A 20 AMPS : 32.8 62 ISPACE A - 11 10 FURN FEED- ISA OFFICE B FHASEBKVA : 3.5 64 SPACE B - 11 12 FURN FEED- ISA OFFICE AMPS: 29.5 66 SPACE C - 11 OTHER KVA : 24.1 14 FHASECKVA : AMPS : 3.1 26.2 68 SPACE A - 1 70 SPACE B - 1 20 11 16 REC- DISHWASHER 153 B 72 SPACE C - 1 74 SPACE A - 1 PHASEA KVA : 20.7 18 CONNECTED LOAD 76 SPACE B - 1 11.7 97.4 0.4 AMPS : KVA : 10.6 78 SPACE C - 1 B 1.9 0.4 AMPS: 29.5 80 SPACE A - 1 1 1.9 1.5 DEMANDLOAD A MPS : 82 SPACE B - 1 20 1 11 KVA : 10.6 84 ISPACE C - 1 A 20 1 0.5 AMPS: 29.5 NOTES/REMARKS: 1. 2. 3. AMPS : 169.8 DEMAND/ DIVERSITY FACTORS LOAD DESCRIPTION R RECEPTACLES- TO 10KVA REMAINING OVER 10KVA H HEATING M MOTORS LM LARGEST MOTOR L LIGHTING K KITCHEN 0 OTHER REC - RECEPTION, DEMO ROOM DEMAND 100% _ 50% _ 100% _ 100% _ 125% _ 125% _ 65% _ 100% = 10.6 E`0.E'I9lz'0 CITY OF TUKWILA. NOV 212016 RERPAIT CENTER v ACKSON I MAIN RCHITECTURE 311 FIRST AVENUE SOUTH SEATTLE, WA 98104 t 206.324.4800 WWW.JACKSONMAIN.COM 19515 North Creek Parkway, Suite 302 Bothell, Washington 98011 hone: 425-402-9400 Fax: 425-402-9402 z ! i PANEL'P1A' PANEL'HA' SEC.1 i I I PROJECT NAME INSPIRUS TUKWILA z PROJECT NAME INSPIRUS TUKWILA PROJECT#: 16163 LOCATION: ROOFTOP PROJECT#: 16163 LOCATION: 1ST FLOOR OPEN OFFICE LOCATION: 1ST FLOOR OPEN OFFICE FED FROM: PANEL HA FED FROM: PANEL HA 1200A BUSSED GUTTER NOTE CKT CIRCUIT NAME NO. CB SIZE -6fAMP P R I NOTE CKT NO. CIRCUIT NAME CB SIZE 8 AM P R LOAD (KVA) H M L K 0 TOTAL PANEL DESCRIPTION 1 REC - MEDIUM CONFERENCE ROOM, TV A 20 1 0.7 A 200 3 0.6 1.3 PANEL AMPS : 200 3 REC - MEDIUM CONFERENCE ROOM, TV B 20 1 0.7 2011 0.3 1.0 FEEDER AMPS : 200 5 REC - MEDIUM CONFERENCE ROOM, TV C 20 1 0.7 C 0.3 1.0 L - L VOLTS : 208 7 FURN FEED - OPEN OFFICE 120 A 20 1 9 1.2 1.2 L- N VOLTS: 120 9 FURN FEED- OPEN OFFICE 120 B 20 1 3 1.2 1.2 PHASE: 3 11 FURN FEED - OPEN OFFICE 120 C 20 1 WIRE : 1.2 1.2 WIRE: 4 13 FURN FEED- OPEN OFFICE 154 A 20 1 1.5 1.2 1.2 15 REC- LOBBY, CONFERENCE, TV 15 FURN FEED - OPEN OFFICE 154 B 20 1 0.2 0.6 1.2 1.4 FLUSH 17 FURN FEED- CALL CENTER C 20 1 1.2 1.2 17 FURN FEED- OPEN OFFICE 154 C 20 1 1 1.2 1.2 ML.O. X FLUSH SURFACE ISO GND 19 REC- OFFICE 157,158, 159, 160 A 20 1 0.7 SPARE B 0.7 MA IN CB W W co 21 REC - OFFICE 157,158 B 20 1 0.5 29 SPARE 0.5 FLUSH X 23 REC - OFFICE 158, 159, 160 C 20 1 0.5 31 SPA RE 0.5 SURFACE 1 �I,p 25 REC- OFFICE 160, 161, CONF 162 A 20 1 0.5 33 SPARE 0.5 ISO GND FEEI}THRU X 27 REC- OFFICE 161, CONF 162 B 20 1 0.7 0.7 29 REC- OFFICE 161, CONF 162 C 20 1 0.7 SPARE C 0.7 1 0.4 90.5 31 SPARE A 20 1 37 SPARE A 20 1 33 SPARE B 20 1 4.2 39 SPA RE B 20 35 SPARE C 20 1 ( TOTAL, ALL SECTIONS) 41 SPARE C 20 37 SPARE A 20 1 REC KVA : 6.3 2 FURN FEED - EXEC OFFICE A 20 1 1 1 0.6 0.6 LOADSUMMARY FURN FEED - EXEC OFFICE 39 SPAREB 1 20 1 A 0.6 HEAT KVA ( TOTAL, ALL SECTIONS) 41 SPARE C 20 1 LIGHTING - PARKING GARAGE B 0.3 REC KVA : 9.7 2 REC - LOCKER ROOMS A 20 1 1.1 1.1 4 REC - STORAGE, IT B 20 1 0.9 C 2011 0.9 HEAT KVA 6.0 6 FURN FEED- ISA OFFICE C 20 1 1 0.6 0.6 MOTOR KVA : 14.6 8 FURN FEED- ISA OFFICE A 20 1 20 0.6 0.6 LIGHTING KVA : 7.6 10 FURN FEED- ISA OFFICE B 20 1 A 0.6 0.6 KITCHEN KVA 12 FURN FEED- ISA OFFICE C 20 1 FURN FEED- CALL CENTER 0.6 0.6 OTHER KVA : 24.1 14 REC - REFRIGERATOR 153 A 20 1 18 0.8 0.8 20 11 16 REC- DISHWASHER 153 B 20 1 105.6 1.5 1.5 PHASEA KVA : 20.7 18 REC- IT C 20 1 0.4 PHASE B KVA AMPS : 11.7 97.4 0.4 AMPS : 172.3 20 REC- IT A 20 1 0.4 B 1.9 0.4 PHASE KVA : 21.0 22 REC - COPIER B 20 1 1.9 1.5 1.5 A MPS : 175.0 24 FURN FEED- RECEPTION C 20 1 11 1.2 1.2 PHASEC KVA : 20.4 26 REC- KFFCHEN, DEMO ROOM A 20 1 0.5 20 1 0.5 AMPS : 169.8 28 REC - RECEPTION, DEMO ROOM B 20 1 0.4 20 1 0.4 30 LTS-1ST FLR C 20 1 1.9 20 1.9 32 LTS-1ST FLR A 20 1 1.9 A 1.9 CONNECTED LOAD 34 LTS-lSTFLR B 20 1 1.9 40 1.9 KVA : 62.0 36 LTS-lSTFLR C 20 1 1.9 39.0 1.9 AMPS: 172.2 38 SPARE A 20 1 AMPS : 108.3 DEMAND LOA D 40 SPARE B 20 1 DEMAND/ DIVERSITY FACTORS LOAD DESCRIPTION R RECEPTACLES - TO 10KVA REMAINING OVER 10KVA H HEATING M MOTORS LM LARGEST MOTOR L LIGHTING K KITCHEN 0 OTHER KVA : 63.9 42 SPARE C 20 1 AMPS : 177.5 NOTES/REMARKS : 1. 2. 3. DEMAND/ DIVERSITY FACTORS LOAD DESCRIPTION R RECEPTACLES - TO 10KVA REMAINING OVER 10KVA H HEATING M MOTORS LM LARGEST MOTOR L LIGHTING K KITCHEN 0 OTHER DBMAND 100% = 50% _ 100% = 100% = 125% _ 125% = 65% _ 100% = 9.7 6.0 14.6 9.5 24.1 E`0.E'I9lz'0 CITY OF TUKWILA. NOV 212016 RERPAIT CENTER v ACKSON I MAIN RCHITECTURE 311 FIRST AVENUE SOUTH SEATTLE, WA 98104 t 206.324.4800 WWW.JACKSONMAIN.COM 19515 North Creek Parkway, Suite 302 Bothell, Washington 98011 hone: 425-402-9400 Fax: 425-402-9402 z ! i PANEL'P2A' PANEL'HA' SEC.1 i I I PROJECT NAME INSPIRUS TUKWILA z PROJECT NAME INSPIRUS TUKWILA PROJECT#: 16163 LOCATION: ROOFTOP PROJECT#: 16163 LOCATION: 1ST FLOOR OPEN OFFICE J m FED FROM: PANEL HA 1200A BUSSED GUTTER NOTE CKT CIRCUIT NAME NO. CB SIZE -6fAMP P R I LOAD (KVA) H M L K 0 NOTE CKT NO. CIRCUIT NAME CB SIZE 8 AM P R LOAD (KVA) H I M I L K 0 TOTAL PANEL DESCRIPTION 1 REC - CONFERENCE, CHAT ROOMS A 20111 A 200 3 0.5 2.0 4.8 1.9 8.0 0.5 PANEL AMPS : 200 3 REC - CONFERENCE, CHAT ROOMS B 2011 5.4 0.5 8.7 0.3 0.8 FEEDER A MPS : 200 5 REC - CONFERENCE, CHAT ROOMS C 20 1 0.5 20.4 L- L V OLTS : L- N VOLTS: 0.5 L- L V OLTS : L- N V OLTS : 208 120 7 REC - CONFERENCE, TV A 20 1 0.7 0.3 1.0 9 REC- CONFERENCE, TV B 20 1 0.7 PHASE: 0.6 1.3 PHASE: 3 11 REC - CONFERENCE TV C 20 1 0.5 4 0.6 1.1 WIRE : 4 13 REC- LOBBY DISHWASHER A 20 1 42kA 15 1.5 1.5 20 1 5.4 15 REC- LOBBY, CONFERENCE, TV B 20 1 0.5 19 0.6 1.1 M.L.O. X MAIN CB FLUSH 17 FURN FEED- CALL CENTER C 20 1 1.2 1.2 19 REC - LA RGE CONFERENCE ROOM A 20 1 0.2 0.2 21 REC - LA RGE CONFERENCE ROOM B 20 1 0.5 B - 1 0.5 FLUSH SURFACE ISO GND X - 23 REC - LA RGE CONFERENCE ROOM, TV C 20 11 0.5 0.3 0.8 25 FRONT LIGHTED SIGN A 20 1 1.2 1.2 27 SPARE B 20 1 W W co FE®-THRU X 29 SPARE C 20 1 SURFACE X U 31 SPA RE A g(1 1 �I,p Z p F- ISO GND 33 SPARE B 20 1 FEED-THRU 35 SPARE C 20 1 0.4 90.5 2 HFL03A A 40 3 14.2 4.2 4 - B - - 4.2 4.2 6 - C - - 4.2 4.2 8 HFL03B A 37 SPARE A 20 1 0 10 - B - LOADSUMMARY 4.2 39 SPA RE B 20 1 A 20 1 0.5 ( TOTAL, ALL SECTIONS) 41 SPARE C 20 1 1-5.4 LOADSUMMARY 0.4 PHASEA KVA REC KVA : 6.3 2 FURN FEED - EXEC OFFICE A 20 1 1 1 0.6 0.6 4 FURN FEED - EXEC OFFICE B 20 1 254.2 10.6 A 0.6 HEAT KVA ! 6 FURN FEED - EXEC OFFICE C 20 1 LIGHTING - PARKING GARAGE B 0.3 0.3 MOTOR KVA 253.0 8 FURN FEED - D(EC OFFICE A 20.1 LIGHTING - PARKING GARAGE C 2011 0.6 0.6 LIGHTING KVA : 8.8 10 FURN FEED - EXEC OFFICE B 20 1 l5_T3_ B 0.6 0.6 KITCHEN KVA LIGHTING KVA 12 FURN FE® - EXEC OFFICE C 20 1 1 0.4 0.6 0.6 OTHER KVA : 21.7 14 FURN FEED - CALL CENTER A 20 1 0.4 0.6 0.6 45.8 14 16 FURN FEED- CALL CENTER B 20 1 0.6 0.6 PHASEA KVA : 12.7 18 REC- SOUTH CONFERENCE C 20 11 0.9 10.9 35.6 18 AMPS : 105.6 20 FURN FEED- CALL CENTER A 20 1 AMPS : 296.8 0.6 0.6 PHASE B KVA AMPS : 11.7 97.4 22 FURN FEED- CALL CENTER B 20 1 0.6 0.6 24 LTS-2ND FLR C 20 1 22 1.9 B 1.9 PHASE C KVA 12.5 26 LTS-2ND FLR A 20 1 SPACE 1.9 - 1 1.9 AMPS : 103.9 28 LTS-2ND FLR B 20 1 1.9 1.9 30 LTS-2ND FLR C 20 11 - 1 1.9 1.9 AMPS : 32 SPARE A 20 1 CONNECTED LOAD 34 SPARE B 20 1 KVA 36.8 36 SPARE C 20 1 KVA : AMPS : 102.2 38 SPARE A 20 1 AMPS : 293.3 DEMA ND LOAD 40 SPARE B 20 1 DEMAND LOAD KVA 39.0 42 SPARE ICI 20 1 KVA 109.4 AMPS : 108.3 NOTESIREMARKS : 1. 2. 3. DEMAND/ DIVERSITY FACTORS LOAD DESCRIPTION R RECEPTACLES -TO10KVA REMAINING OVER 10KVA H HEATING M MOTORS LM LA RGEST MOTOR L LIGHTING K KFFCHEN 0 OTHER AMPS : DEMAND 100% = 50% _ 100% _ 100% _ 125% _ 125% = 65% _ 100% = 6.3 11.0 21.7 E`0.E'I9lz'0 CITY OF TUKWILA. NOV 212016 RERPAIT CENTER v ACKSON I MAIN RCHITECTURE 311 FIRST AVENUE SOUTH SEATTLE, WA 98104 t 206.324.4800 WWW.JACKSONMAIN.COM 19515 North Creek Parkway, Suite 302 Bothell, Washington 98011 hone: 425-402-9400 Fax: 425-402-9402 z ! i PANEL'HB' PANEL'HA' 0 i I I PROJECT NAME INSPIRUS TUKWILA z PROJECT NAME INSPIRUS TUKWILA PROJECT#: 16163 LOCATION: ROOFTOP PROJECT #: 16163 LOCATION: BASEMENT MAIN ELECTRICAL ROOM J m FED FROM: 1200A BUSSED GUTTER NOTE CKT CIRCUIT NAME NO. CB SIZE -6fAMP P R I LOAD (KVA) H M L K 0 TOTAL NOTE CKT NO. CIRCUIT NAME CB SIZE B AM P R LOAD (KVA) H M I L K 0 TOTAL PANE- DESCRIPTION 1 SUBFEED- PANEL P1 A 200 3 4.0 2.0 4.8 1.9 8.0 20.7 PANELAMPS : 400 5 - C - - 5.4 501 "a 8.7 21.0 FEEDER AMPS : 400 5 - C - - 2.3 2.0 4.8 3.8 7.4 20.4 L- L V OLTS : L- N VOLTS: 208 120 7 SUBFEED- PANEL P2A A 200 3 1.4 1 3.1 8.1 12.7 9 - B - - 2.3 1 1.9 7.4 11.7 PHASE: 3 11 - C - -1 2.5 3.8 6.1 12.5 WIRE: 4 13 GF -1 A 20 1 3 5.4 5.4 M.L.O. AIC: 42kA 15 GF -2 B 20 1 5.4 5.4 MAIN CB X 400A 23 - 17 GF -3 C 20 1 19 GF -4 A 20 1 FLUSH 25 SPACE M.L.O. - 1 21 SPACE B - 1 27 SPACE B - MAIN CB X 400A 23 SPACE C - 1 W W co FLUSH 25 SPACE A - 1 SURFACE X U 27 SPACE B - 1 �I,p Z p F- ISO GND 29 SPACE C - 1 FEED-THRU REC KVA : HEAT KVA MOTOR KVA : 0.4 90.5 2 HFL03A A 40 3 14.2 4.2 4 - B - - 4.2 4.2 6 - C - - 4.2 4.2 8 HFL03B A 40 3 4.2 4.2 LIGHTING KVA 0 10 - B - - 4.2 42 KITCHEN KVA OTHER KVA co 12 - C - - 4.2 4.2 14 EF -2 A 20 1 0.5 0.5 16 REC- ROOFTOP B 20 1-5.4 LOADSUMMARY 0.4 PHASEA KVA 30.5 18 ISPARE C 20 1 LU I- ( TOTAL, ALL SECTIONS ) AMPS : 254.2 20 ISPACE A - 1 ! 00 - REC KVA 16.0 2 LIGHTING - PARKING GARAGE A 2011 1.9 1.9 4 LIGHTING - PARKING GARAGE B 20 11 r-- co t I 1.9 I 253.0 1.9 HEAT KVA : 6.0 6 LIGHTING - PARKING GARAGE C 2011 30.0 1.9 A 1.9 MOTOR KVA : 15.7 8 SP -1 A l5_T3_ B 0.4 1 0.4 LIGHTING KVA 22.1 10 - B - - 1 0.4 0.4 KITCHEN KVA 121- C - - 0.4 0.4 OTHER KVA : 45.8 14 SPACE A - 3 16 - B - - PHASEA KVA : 35.6 18 - C - - KVA AMPS : 92.2 256.0 AMPS : 296.8 20 SPACE A - 1 DEMAND 100% = 50% _ 100% _ 100% = 125% = 125% _ 65% _ 100% _ 0.4 85.1 6.8 PHA SEB KVA 35.0 22 SPACE B - 1 AMPS : 291.3 24 SPACE C - 1 PHASE KVA 35.1 26 SPACE A - 1 AMPS : 292.5 28 SPACE B - 1 30 SPACE C - 1 CONNECTED LOAD KVA : 105.7 AMPS : 293.3 DEMAND LOAD KVA 109.4 AMPS : 303.8 NOTES/REMARKS: 1. 2. 3. DEMAND/ DIVERSITY FACTORS LOAD DESCRIPTION R RECEPTACLES - TO 10KVA REMAINING OVER 10KVA H HEATING M MOTORS LM LARGEST MOTOR L LIGHTING K KITCHEN 0 OTHER DEMAND 100% = 50% = 100% = 100% = 125% = 125% = 65% _ 100% = 10.0 3.0 6.0 10.7 6.3 27.6 45.8 E`0.E'I9lz'0 CITY OF TUKWILA. NOV 212016 RERPAIT CENTER v ACKSON I MAIN RCHITECTURE 311 FIRST AVENUE SOUTH SEATTLE, WA 98104 t 206.324.4800 WWW.JACKSONMAIN.COM 19515 North Creek Parkway, Suite 302 Bothell, Washington 98011 hone: 425-402-9400 Fax: 425-402-9402 z ! i PANEL'HB' 1 0 i I I PROJECT NAME INSPIRUS TUKWILA z PROJECT#: 16163 LOCATION: ROOFTOP FED FROM: 1200A BUSSED GUTTER J m NOTE CKT CIRCUIT NAME NO. CB SIZE -6fAMP P R I LOAD (KVA) H M L K 0 TOTAL PANEL DESCRIPTION 1 HP -01A Al50 � 3 5.4 5.4 PANELAMPS : 400 3 - B - - 5.4 5.4 FEEDER AMPS : 400 5 - C - - 5.4 5.4 L-LVOLTS: 208 7 HP -01B A 50 3 5.4 5.4 L- N VOLTS : 120 9 - B - - 5.4 5.4 PHASE: WIRE: AIC: 3 4 42kA 11 - C - - 5.4 r 5.4 13 HP -02A A 50 31 5.4 5.4 15 - B - - 5.4 5.4 F- 17 - C - - 5.4 5.4 Z IW 19 HP -02B A 50 3 5.4 5.4 M.L.O. 21 - B - - 5.4 5.4 MAIN CB X 400A 23 - C - - 5.4 5.4 FLUSH 25 SPACE A - 1 ~ SURFACE X 27 SPACE B - 1 ISO GND FEED-THRU 29 SPACE C - 1 W W co U �I,p Z p F- LOADSUMMARY WIU (D ( TOTAL, ALL SECTIONS) REC KVA : HEAT KVA MOTOR KVA : 0.4 90.5 2 HFL03A A 40 3 14.2 4.2 4 - B - - 4.2 4.2 6 - C - - 4.2 4.2 8 HFL03B A 40 3 4.2 4.2 LIGHTING KVA 0 10 - B - - 4.2 42 KITCHEN KVA OTHER KVA co 12 - C - - 4.2 4.2 14 EF -2 A 20 1 0.5 0.5 16 REC- ROOFTOP B 20 1-5.4 0.4 PHASEA KVA 30.5 18 ISPARE C 20 1 LU I- ` C -D O N.N AMPS : 254.2 20 ISPACE A - 1 ! 00 - PHASE B KVA 30.4 22 ISPACE B - 1 r-- co t I AMPS : 253.0 24 SPACE C - 11 PHASE C KVA : 30.0 26 SPACE A - 11 AMPS : 250.0 28 SPACE B - 1 30 SPACE C - 1 CONNECTED LOAD KVA 90.9 AMPS : 252.2 DEMAND LOAD KVA AMPS : 92.2 256.0 NOTES/REMARKS: 1. 2. 3. DEMAND / DIVERSITY FACTORS LOAD DESCRIPTION R RECEPTACLES - TO 10KVA REMAINING OVER 10KVA H HEATING M MOTORS LM LARGEST MOTOR L LIGHTING K KITCHEN 0 OTHER DEMAND 100% = 50% _ 100% _ 100% = 125% = 125% _ 65% _ 100% _ 0.4 85.1 6.8 E`0.E'I9lz'0 CITY OF TUKWILA. NOV 212016 RERPAIT CENTER v ACKSON I MAIN RCHITECTURE 311 FIRST AVENUE SOUTH SEATTLE, WA 98104 t 206.324.4800 WWW.JACKSONMAIN.COM 19515 North Creek Parkway, Suite 302 Bothell, Washington 98011 hone: 425-402-9400 Fax: 425-402-9402 z ! i 1 0 i I I z z J m O W f - Uj 00 oo � -z a ao U W w Q Z U W Q U 0n U 05� U) z LL 0 CV Z) W LTO I- Z ! i 1 i I I O I U i U W W i W ! F- U Z IW z LU W �Ua.UIQ 2 Wi-� ~ O ~ W W �I- J W W 2W W W co U �I,p Z p F- WIU (D Ui0 W C:)! W: I U i co 0 L5 0- i O -IN co -gr 1r) i Z I I CD (0 4LO ! co co LU I- ` C -D O N.N O N o i o N E N 00 - O N) � Cic- r-- co t I co ia-- r ! r i t i PROJECT NO.: 16040 / C16163 PROJECT MGR.: LM DRAWN BY: CJP CHECKED BY: MSC PANEL SCHEDULES JACKSON I MAIN ARCHITECTURE P.S. © 2015 NORTH PARKING LEVEL LIGHTING PLAN_ SCALE: 1/8" = V-101" p Calculation Summary Label CalcType Units Avg Max Min Avg/Min Max/Min EMERGENCY EGRESS PATHWAY Illuminance Fc 1.45 4.8 0.2 7.25 24.00 R E C E i V te- 1f,"I i Y OF T UKWILA, NOV 212016 PERMIT CENTER 19515 North Creek Parkway, Suite 302 Bothell, Washington 98011 Phone: 425-402-9400 Fax: 425-402-9402 z \0\ 00 06 Q 06 w rn o I w� Cl)� Q J O Z CC Z) ON= O O i - N W z i O o I Z J m O 0� W LLJ . co �p z00 (� 0 w Q Cn Q z D W DQ I _ U O —� CLU Lt_ U) z LL o F -) Q ; LCrq) z PARKING i o I CL U I CLU Q ; U ~ ' LU U i- iI Ui Z!L Z� w UIw LU .0 U IOW w w > >00 UJ of W 0 �!c Q•, SIU Z pif— i w10 U UIQ =o o IX U:o w oiw Uco 0 U510- 5i0- o C; i Z S I N Cl)� LO CD CD (0I( w H 070 N N 0 N 0,0 N, N Q 00 .-Ir- o N 01� CIZZ r 00 I- i 00 00 C) �I r, PARKING LEVEL LIGHTING CALCULATION PLAN 4 s � JACKSON I MAIN ARCHITECTURE P.S. © 2015 0 W --P