Loading...
HomeMy WebLinkAboutPermit EL16-1076 - TUKWILA VILLAGE / BUILDING D - SUITE A WIRINGTUKWILA VILAGE BUILDING D 14400 TUKWILA INTERNATIONAL BLVD EXPIRED 12/04/17 ELl 6=1 076 City of Tukwila • Department of Community Development • 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Inspection Request Line: 206-438-9350 Web site: http://www.TukwilaWA.gov Parcel No: 0040000180 ELECTRICAL PERMIT Permit Number: EL16-1076 Address: 14400 TUKWILA INTERNATIONAL Issue Date: 12/6/2016 BLVD Permit Expires On: 6/4/2017 Project Name: TUKWILA VILLAGE BUILDING D Owner: Name: TUKWILA CITY OF Address: 6200 SOUTHCENTER BLVD, TUKWILA, WA, 98188 Contact Person: 2015 Name: MITCH CHAMBERLIN Address: PO BOX 849, SUMNER, WA, 98390 Contractor: 2014 Name: EVERGREEN STATE ELECTRIC INC Address: PO BOX 849, SUMNER, WA, 98390 License No: EVERGSE066JA Lender: 2015 Name: 2015 Address: DESCRIPTION OF WORK: WIRE ONE TENANT IMPROVEMENT IN SUITE W Valuation of single family: $0.00 Valuation of mf/comm: $80,000.00 Type of Work: TENANT IMP Phone: (253) 770-0656 Phone: (253) 770-0656 Expiration Date: 4/1/2018 Fees Collected: $1,776.00 Electrical Service Provided by: SEATTLE CITY LIGHT Water District: 125 Sewer District: VALLEY VIEW Current Codes adopted by the City of Tukwila: International Building Code Edition: 2015 National Electrical Code: 2014 International Residential Code Edition: 2015 WA Cities Electrical Code: 2014 International Mechanical Code Edition: 2015 WAC 296-4613: 2014 Uniform Plumbing Code Edition: 2015 WA State Energy Code: 2015 International Fuel Gas Code: 2015 t Permit Center Authorized Signature: Date: 11,0 I hearby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this development permit and agree to the conditions attached to this permit. / Signature: �� it �c� Date: Print Name: This permit shall become null and void if the work is not commenced within 180 days for the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. PERMIT CONDITIONS: <NONE> PERMIT INSPECTIONS REQUIRED Permit Inspection Line: (206) 438-9350 2100 ELECTRICAL FINAL 7003 ROUGH -IN ELECTRICAL 7002 SERVICE 7001 UNDERGROUND/SLAB CITY OF TUKWi- . Community Development Department • t� Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://www.TukwilaWA.gov SITE LOCATION Electrical Permit No..j Project No. Date Application Accepted: Date Application Expires: MCI ELECTRICAL PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. "Please Print" �q '' II' /I , V"1 King Co Assessor's Tax No.: Site Address: A DO -TU « TF IAV1 A1- &VO Suite Number:. Floor: Tenant Name: //Vi�.t p-P�G11`it. - LNi1tiG New Tenant: Q ....Yes ❑..No PROPERTY OWNER Name: �VKw y -A YINa veri c Address. ')q _ 27-&iJ- 50 UlG A sar City: AkIA, State: Zip LMA, CONTACT PERSON — person receiving all communication project Name: 1W tfCb, tq Type of work: Address: Addition ❑ Low Voltage ❑ City: State: WA. Zip- 6� Phone X3 -'7p_ . Fax: ?6- /767 Email: ELECTRICAL CONTRACTOR INFORMATION Company Name: Address: City: State: Zip: Phone: Fax: Contr Reg No.: Exp Date: Tukwila Business License No.; Valuation of Project (contractor's bid price): $ i 0 U t amC_A, Scope of Work (please provide detailed information): W 112.4- DiU T 17P.NAfff- Will service be altered? ❑ Yes Type of Use: Type of work: New ❑ Addition ❑ Low Voltage ❑ Generator Property Served by: ❑ Puget Sound Energy Wr W ❑ Service Change ❑ Fire Alarm Seattle City Light H:\Applications\Forms-Applications On Line\2014 ApplicationsTlectrical Permit Application Revised 1-1-14.docx Revised: July 2013 bh Adding more than 50 amps? ❑ Yes ❑ Remodel ❑ Telecommunication ❑ No PI/Tenant Improvement ❑ Temporary Service Pagel of 2 RESIDENTIAL NEW RESIDENTIAL SERVICE ❑ New single family dwellings ...................................$152.85 (including an attached garage) ❑ Garages, pools, spas and outbuildings ........................$81.90 ea ❑ Low voltage systems (alarm, furnace thermostat).................................$59.85 ea RESIDENTIAL REMODEL AND SERVICE CHANGES ❑ Service change or alteration .......................................$81.90 ❑ (no added/altered circuits) $80.90 ❑ Service change with added/altered circuits.................$81.90 $86.25 number of added circuits ....................... $11.55 ea ❑ Circuits added/altered without service change ............ $54.60 (up to 5 circuits) $10.80 ea ❑ Circuits added/altered without service change ............ $54.60 (6 or more circuits)...............................................$7.65 ea ❑ Meter/mast repair ........................................................$68.25 ❑ Low voltage systems .................................................$59.85 (alarm, furnace thermostat) PERMIT APPLICATION NOTES - MULTI -FAMILY AND COMMERCIAL Fees are based on the valuation of the electrical contract. MISCELLANEOUS FEES ❑ Temporary service (residential) .................................. $65.00 ❑ Temporary service (generator) ................................... $80.90 ❑ Manufactured/mobile home service ........................... $86.25 (excluding garage or outbuilding) ❑ Carnivals.................................................................... $80.60 Number of concessions ......................... $10.80 ea Each ride and generator.truck................$10.80 ea ***EFFECTIVE JANUARY 1, 2014 EACH PERMIT WILL BE ASSESSED A 5% TECHNOLOGY FEE*** Value of Construction – In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review – Applications for which no permit is issued within 180 days following the date of application shall expire by limitation The Building Official may grant one extension of time for an additional period not to exceed 90 days. The extension shall be requested in writing and justifiable cause demonstrated. I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER OR ELECTRICAL CONTRACTOR: Date: /1-,93'16 Print Name: (�� o /7L'��`i� Day Telephone:,2 5-3 &_16 19 12— Mailing Address: �T f 7(AL 'Iz�.� 4t16 49TJ _3w City State Zip H:\ApplicationsTorms-Applications On Line\2014 ApplicationsTlectrical Permit Application Revised 1-1-14.docx Revised: July 2013 bh Page 2 of 2 Date Paid: Wednesday, November 23, 2016 Paid By: EVERGREEN STATE ELECTRIC Pay Method: CHECK 1070 Printed: Wednesday, November 23, 2016 10:37 1 of 1 �'r—jf fl SYSTEMS AM DESCRIPTIONS • QUANTITY PAID PermitTRAK $1,434.46 EL16-1076 Address: 14400 TUKWILA INTERNATIONAL BLVD Apn: 0040000180 $1,434.46 ELECTRICAL $1,366.15 PERMIT FEE MULTI-FAM/COMM R000.322.101.00.00 0.00 $1,366.15 TECHNOLOGY FEE $68.31 TECHNOLOGY FEE R000.322.900.04.00 0.00 TOTAL PAID BY RECEIPT:.... $68.31 i Date Paid: Tuesday, December 06, 2016 Paid By: EVERGREEN REFRIGERATION Pay Method: CHECK 1073 Printed: Tuesday, December 06, 2016 2:49 PM 1 of 1 (r—P SYSTEMS 2015 Washington State Energy Code Compliance Forms for Commercial Buildings including R2, R3, R4 over Project Title: Tukwila Bldg. D Tenant Improvement Date 10/3/2016 Calculation Area NOTE 8 O Addition - O Addition stand alone + existing Q Spaces where < 50% of 0 Spaces where >_ 50% of O luminaires are replaced luminaires are replaced For Building Department Use LPA Calculation Type • Standard O Additional Efficiency Package Option O C406.3 Reduced Interior Lighting Power To comply vuth C406.3, the Proposed LPD shall be 25% /ovier than the Target LPA. Refer to C406.3 for additional requirements. Maximum Allowed Lighting WattagWTE , 576 Building Area Location (plan #, Gross Interior room #, or ALL) Area Description Area in ff Allowed Watts Allowec Watts per ff (watts/ff x area) Office Tenant Improvement Office Area 24100 0.66 15906 LED Downlight 32 15 480 Office 2x4 LED Troffer 62 45 2790 Office 1'x4' LED Troffer 13 30 390 Office Linear, LED, Recessed (5 watts per foot) 1066 5 Total 24100 Proposed Lighting Wattage Building Area Location (plan #, room #) Fixture Description NOTE 2, 3, 4, 5 Number of Fixtures Watts per Fixture NOTE 6 Watts Proposed Office 2 -Lamp, T8, Fluorescent Surface Mount 9 64 576 Office 2 -Lamp, T8, Fluorescent Wall Mount 2 64 128 Office LED Downlight 32 15 480 Office 2x4 LED Troffer 62 45 2790 Office 1'x4' LED Troffer 13 30 390 Office Linear, LED, Recessed (5 watts per foot) 1066 5 5330 Office LED Exit Sign 9 3 27 Compliance by Building Area "OTE' Building Area Warnings Total Allowed Watts Total Proposed Watts Interior Lighting Power Allowance Office 15906 9721 COMPLIES Note 1 - List all unique building areas per Table C405.4.2(1) that occur in the Totalsl 15906 1 9721 , project scope. Select building area category from drop doW7 menu. Note 2 - Proposed fixtures must be listed in the building area in Mich they occur. List all proposed lighting fixtures including exempt lighting equipment and existing -to -remain fixtures. Note 3 - For proposed Fixture Description, indicate fixture type, lamp type (e.g. T-8), numberof lamps in the fixture, and ballast type (if included). For track lighting, list the length of the track (in feet) in addition to the fixture, lamp, and ballast information. Note 4 - For lighting equipment eligible for exemption per C405.4.1, note exception number and leave Watts/Fixture blank. Note 5 - Existing -to -remain fixtures shall be included in the Proposed Lighting Wattage table in the same manner as new fixtures. Identify as existing in fixture description. Note 6 - For proposed Watts/Fixture enter the luminaire v attage for installed lamp and ballast using manufacturer or other approved source. For City of Tukwila Department of Community Development 11/2/2017 MITCH CHAMBERLIN PO BOX 849 SUMNER, WA 98390 RE: Permit No. EL16-1076 TUKWILA VILLAGE BUILDING D 14400 TUKWILA INTERNATIONAL BLVD Dear Permit Holder: Allan Ekberg, Mayor Jack Pace, Director In reviewing our current records, the above noted permit has not received a final inspection by the City of Tukwila Building Division. Per the International Building Code, International Mechanical Code, Uniform Plumbing Code and/or the National Electric Code, every permit issued by the Building Division under the provisions of these codes shall expire by limitation and become null and void if the building or work authorized by such permit has not begun within 180 days from the issuance date of such permit, or if the building or work authorized by such permit is suspended or abandoned at any time after the work has begun for a period of 180 days. Your permit will expire on 12/4/2017. Based on the above, you are hereby advised to: 1) Call the City of Tukwila Inspection Request Line at 206-438-9350 to schedule for the next or final inspection. Each inspection creates a new 180 day period, provided the inspection shows progress. -or- 2) Submit a written request for permit extension to the Permit Center at least seven(7) days before it is due to expire. Address your extension request to the Building Official and state your reason(s) for the need to extend your permit. The Building Code does allow the Building Official to approve one extension of up to 180 days. If it is determined that your extension request is granted, you will be notified by mail. In the event you do not call for an inspection and/or receive an extension prior to 12/4/2017, your permit will become null and void and any further work on the project will require a new permit and associated fees. Thank you for your cooperation in this matter. Sincerely, A- —PJ Bill Rambo Permit Technician File No: ELI 6-1076 6300 Southcenter Boulevard Suite #100 9 Tukwila, Washington 98188 • Phone 206-431-3670 • Fax 206-431-3665 May 9, 2017 City of Tukwila Department of Community Development - Jack Pace, Director Francine Boyd Evergreen State Electric PO Box 849 Sumner, WA 98390 RE: Request for Extension #1 Permit Number EL16-1076 Dear Ms. Boyd, Allan Ekberg, Mayor This letter is in response to your written request for an extension to Permit EL16-1076. The Building Official, Jerry Hight, has reviewed your letter and considered your request to extend the above referenced permit. It has been determined that the City of Tukwila Building Division will be granting an extension to the permit through December 4, 2017. If you should have any questions, please contact our office at (206) 431-3670. Sincerely, Bill Rambo Permit Technician File: Permit No. ELI 6-1076 Tukwila City Hall • 6200 Southcenter Boulevard • Tukwila, WA 98188 • 206-433-1800 • Website: TukwilaWA.gov 05/08/2017 MON 10:08 FAX 2! 70 1767 Evergreen State Electric 9�/,I AFONJJEJEW 'LEC TR /C Rdrldentlal a Comm orclel a lndusWal iAlarm To: City of Tukwila Permit Counter RE: Permit # EL16-1076 Tukwila Village Building D Tenant Improvement 34400 Tukwila International Blvd. 05/08/2017 /0001/002 Mello, I would like to aslc for an extension on permit #EL16-1076 we are still in progress with the building and cannot call in any inspection at this time. This particular building is being built at this time and we have not done any electrical work yet at this location. Thank You, Francine Boyd Q!o-- 6-T)Y'6�� Permit Specialist Evergreen State Electric, Inc. Request for /_Extension # Current Expiration Date: 6 Extension Request: Approved for _ 1 days ❑ Denied (provide explanation) Signature/initials I RECEIVED CITY OF TUKWILA MAY 0 8 2011 PERMIT CENTER P.O. Box 849, Sumner, Wa®hln pn 98390 • (263) 7700M • 1.600.4914936 • FAX (259) 770.1767 5/1/2017 City of Tukwila Allan Ekberg, Mayor Department of Community Development Jack Pace, Director MITCH CHAMBERLIN PO BOX 849 SUMNER, WA 98390 RE: Permit No. ELI 6-1076 pTUKWILA VILLAGE BUILDING D 14400 TUKWILA INTERNATIONAL BLVD Dear Permit Holder: In reviewing our current records, the above noted permit has not received a final inspection by the City of Tukwila Building Division. Per the International Building Code, International Mechanical Code, Uniform Plumbing Code and/or the National Electric Code, every permit issued by the Building Division under the provisions of these codes shall expire by limitation and become null and void if the building or work authorized by such permit has not begun within 180 days from the issuance date of such permit, or if the building or work authorized by such permit is suspended or abandoned at any time after the work has begun for a period of 180 days. Your permit will expire on 6/4/2017. Based on the above, you are hereby advised to: 1) Call the City of Tukwila Inspection Request Line at 206-438-9350 to schedule for the next or final inspection. Each inspection creates a new 180 day period, provided the inspection shows progress. -or- 2) Submit a written request for permit extension to the Permit Center at least seven(7) days before it is due to expire. Address your extension request to the Building Official and state your reason(s) for the need to extend your permit. The Building Code does allow the Building Official to approve one extension of up to 180 days. If it is determined that your extension request is granted, you will be notified by mail. In the event you do not call for an inspection and/or receive an extension prior to 6/4/2017, your permit will become null and void and any further work on the project will require a new permit and associated fees. Thank you for your cooperation in this matter. Sincerely, Bill Rambo Permit Technician File No: ELI 6-1076 6300 Southcenter Boulevard Suite #100 9 Tukwila, Washington 98188 • Phone 206-431-3670 0 Fax 206-431-3665 vERMIT COORD COP`S: PLAN REVIEW/ROUTING SLIP PERMIT NUMBER: EL16-1076 DATE: 11/23/16 PROJECT NAME: TUKWILA VILLAGE BUILDING D - SUITE 1 SITE ADDRESS: 14400 TUKWILA INTERNATIONAL BLVD X Original Plan Submittal Response to Correction Letter # DEPARTMENTS: wv- Building Division Revision # before Permit Issued Revision # after Permit Issued Fire Prevention ❑ Planning Division ❑ Public Works ❑ Structural ❑ Permit Coordinator PRELIMINARY REVIEW: - DATE: 11/24/16 Not Applicable ❑ Structural Review Required ❑ (no approval/review required) REVIEWER'S INITIALS: APPROVALS OR CORRECTIONS: DATE: DUE DATE: 12/22/16 Approved ❑ Approved with Conditions ❑ Corrections Required ❑ Denied ❑ (corrections entered in Reviews) (ie: Zoning Issues) Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: 12/18/2013 EVERGREEN STATE ELECTRIC r ` Page 1 of 3 Home ESpanol Contact Search L&I A-7, Index Help a1y Im Safety & Health Claims & Insurance Workplace Rights Trades & Licensing Washington State Department of JI-abor & Industries EVERGREEN STATE ELECTRIC INC Owner or tradesperson PO BOX 849 SUMNER, WA 98390 Principals 253-770-0656 CHAMBERLIN, MITCHELL, PRESIDENT PIERCE County CHAMBERLIN, LYNDA K, VICE PRESIDENT CHAMBERLIN, LYNDA, AGENT WILKINSON, JESSICA, SECRETARY (End: 12/26/2012) Doing business as EVERGREEN STATE ELECTRIC INC WA UBI No. Business type 601 521 666 Corporation Governing persons LYNDA K CHAMBERLIN MITCHELL D CHAMBERLIN; License Verify the contractor's active registration / license / certification (depending on trade) and any past violations. Electrical Contractor Active. .......................................................... . Meets current requirements. License specialties GENERAL License no. EVERGSE066JA Effective — expiration 04/01/1994— 04/01/2018 Designated administrator Active. CHAMBERLIN, MITCHELL Meets current requirements. License type License no. Master Electrician CHAMBM*977KG Bond ............ Contractors Bonding & Insurance Co $4,000.00 Bond account no. SJ5622 Received by L&I Effective date 04/24/2012 04/01/2012 Expiration date Until Canceled Bond history Savings No savings accounts during the previous 6 year period. Help us improve https:Hsecure.Ini.wa.gov/verify/Detail.aspx?UBI=601521666&LIC=EVERGSE066JA&SAW= 12/6/2016 ELECTRICAL SYMBOLS LEGEND A DETAIL/SECTION IDENTIFICATION: A = DETAIL/SECTION LETTER, B = SHEET NUMBER S LIGHT SWITCH TOGGLE TYPE, SINGLE POLE, SUBSCRIPTS; 3 =THREE WAY, 4 = B WHERE DETAIL/SECTION IS DRAWN. FOUR WAY, D = DIMMER CONTROL, K KEY OPERATED, P = PILOT LIGHT, a, b, c, A EQUIPMENT CONNECTION CALLOUT. A,13EQUAL EQUIPMENT IDENTIFICATION ON ETC = NUMBER OF SWITCHES AT THE LOCATION AND SPECIFIC FIXTURES B CONTROLLED. MOUNT AT 42 INCHES AFF. MECHANICAL EQUIPMENT CONNECTION SCHEDULES. VERIFY EXACT EQUIPMENT REQUIREMENTS ON SHOP DRAWING EQUIPMENT SUBMITTALS PRIOR TO ROUGH -IN. DO NO ROUGH -IN FOR EQUIPMENT PRIOR TO REVIEW OF SUBMITTALS. REPORT ANY - DISCONNECT SWITCH TO ENGINEER IN DIFFERENCES IN REQUIREMENTS WRITING.. F USED DISCONNECT SWITCH WITH FUSES: CONDUIT CONCEALED. HASH MARKS INDICATE NUMBER OF #12 CONDUCTORS IN CODE SIZE CONDUIT. NO HASH MARKS INDICATES 2412 CONDUCTORS PLUS GROUND IN 3/4 Sm MOTOR RATED TOGGLE SWITCH WiTH OVERLOAD HEATER(S), SIZE PER NEC AND CONDUIT, LONG HASH MARKS INDICATES NEUTRAL CONDUCTOR. INDICATES GROUND MANUFACTURERS REQUIREMENTS. CONDUCTOR. 2 0 FLUSH MOUNTED DUAL TELEPHONE/DATA OUTLET, MOUNT AT 18" AFF. PROVIDE f NON-METALLIC SHEATHED CABLE 1212 CU WITH GROUND .4-11/16" SQUARE BOX WITH 1-1/4" CONDUIT.AND PULL STRING TO ACCESSIBLE f3 NON-METALLIC SHEATHED CABLE 12/3 CU WITH GROUND CEILING SPACE. FLEXIBLE RACEWAY, PROVIDE GROUND CONDUCTCRS PER NEC. QT TRANSFORMER. SIZE AND TYPE AS NOTED. PROVIDE GROUNDING AS REQUIRED BY NEC. -�- A-1,3 ADJACENT TO ARROW INDICATES HOMERUN OF CONDUCTORS IN CONDUIT FOR CIRCUITS 1 AND 3 TO PANEL "A•• _ GROUND PER NEC - EXIT LIGHT WITH BATTERY, UNIVERSAL MOUNTING. SC `COMBINATION SMOKE/ CARBON MONOXIDE DETECTOR WITH. SOUNDER BASE EMERGENCY FLOODLIGHT WITH BATTERY. PS DAYLIGHT PHOTOSENSOR. 0-10V WITH DUAL OUTPUT AND POWER PACK. 0 LIGHT FIXTURE, SURFACE MOUNTED ON CEILING., 2 -LAMP, T8, WRAPAROUND, 64 WATTS (E) EXISTING LIGHT FIXTURE, 2'X 4', RECESSED, LED, 45 WATTS IAID IA/CATUMD00nnc O u Ln bp. N L!J N O i O h �I in CL v 0 i ro n. a 0 u v A v E m 0 N M 0 L:� v ( 6.3 L 1 LIGHTING P"LAN N SCALE: 1/8"=1'-0" SCALE: 1/8"=1'-0" . V. CL SCALE: 1/8"=1'-0" �! V m>, o sr m. w N i tp 0 tl in . 0029060 NAL 10/3/16 SCALE: AS NOTED' DATE: SHEET 10-3-16 DRAWN Y: JAE 01 CHECKED BY: E31 SLH/GLW JOB NO.: OF 16-072 - 0 a SCALE: 1/8"=l' -O" J PULL SECT. 800A •®'O O •®O •® ■Q yr O �O 0 ■Q •® •® 0.0 ®•® 100A � '. ■M 00000000 ■M ��, ■M M ■M M ■M M s ■M 0000000® ■M M ■M M ■M M ■ PULL ■®•® ®•® ®•® ®•® sECT.00000000 ■M ■M M •M M ■M M •M 800A •® •® ®•® ®•® ®•O 100A, 208V; 1 PH, PSE METER AND METER BASE WITH 100A/2 -POLE 4TH FLOOR CIRCUIT BREAKERS. KE S. TYPICAL OF 40. PULL SECT. 800A •®'O O •®O •® ■Q •O O �O 0 ■Q •® •® 0.0 ®•® 100A, 208V, 1 PH, PSE METER AND METER BASE WITH 100Al2-POLE 2ND FLOOR _ _ _ CIRCUIT BREAKERS' TYPICAL OF 28. SURFACE MOUNTING SURFACE MOUNTING SURFACE MOUNTING PANEL SCHEDULE PANEL SCHEDULE -PANEL SCHEDULE 22,000 AIC 22 000 AIC 22 000 AIC NO. LOCATION: ' TENANT SPACE 120/208 VOLTS 3PHASE 4WIRE No LOCATION: TENANT SPACE 120/208 VOLTS 3PHASE 4WIRE No LOCATION: TENANT SPACE 120/208 VOLTS 3PHASE 4WIRE T1 T2 T3 SERVING. TENANT SPACE 200 AMPS WITH MAIN LUGS SERVING. TENANT SPACE 400 AMPS WITH MAIN LUGS SERVING: TENANT SPACE 200 AMPS WITH MAIN LUGS CKT TRIP TRIP CKT CKT TRIP TRIP CKT CKT TRIP TRIP CKT No, LOAD DESCRIPTION KVA AMPS AMPS KVA LOAD DESCRIPTION No. No. LOAD DESCRIPTION KVA AMPS AMPS KVA LOAD DESCRIPTION No. No. LOAD DESCRIPTION KVA KVA LOAD DESCRIPTION k . AMPS AMPS N0, 1 RECEPT. OFFICE 902 SO3 1.26 20 20 1.26 RECEPT. OFFICE SO1 SO4 2 1 AH-3 11.90 60 60 11.19 AH-4 2 1 S02 SO3 SO4 SO5 CORR. LTS .78 20 20 .64 SHAG OFF. S31 S30 COR. LTS 2 3 RECEPT. OFFICE S32 1.62 1.70 R.R.IRECEPT. OFFICE S05 4 3 2 2 4 3 LOBBY ENTRY LIGHTS 66 .81 WORK RM. S06 COR. LIGHTS 4' 5 RECEPT. OFFICE S31 S32 1.44 1.62 RECEPT: S29 S28 6 5 AH-6 8.32 50 50 8.32 AH-7 6 5 REC. U-SHAPED TRACK 1.30 .95 CORRIDOR STRIP LIGHTING 6 7 RECEPT. OFFICE S06 S27 1.26 1.50 RECEPT. 06 EQUIP. 8 7 2 2 8 F13 OFFICE x 11 LIGHTS .80 .38 OFFICE x 2 CORRIDOR LTS 8 t.: 9 RECEPT. OFFICE 909 SO8 1.44 1.26 RECEPT. S26 10 9 AH-8 8.32 56 60 11.19 AH-5 10 S46 S45 S44 S43 CORR. LTS .80 1.00 OPEN OFFICE LIGHTS 10 RECEPT. S24 .90 1.08 RECEPT. S25 S25A 12 11 - 2 2 12 CONF. S38 CORRIDOR LTS_ 11 71 1.00 TRAINING S26 LIGHTS 12 13 AH-10 8.32 50 50 8.32 AH-9 13 RECEPT. S24 90 1.44 RECEPT. S22 S23 14 14 BOARD ROOM LIGHTS 80 .81 JAN S35 LUNCH COR. LTS 14 15 RECEPT. S10 S13 Sl l 1.62 1.62 RECEPT. 14,1516 15 2 2 16 15 SHAG OFFICE S32 1.00 20 20 1.00 PRODUCTION S25 LIGHTS 16 17 RECEPT. S16 S-17 1.08 20 1.50 S19 SPECIAL EQUIP. 18 17 CU-3 4.16 30 30 4.16 CU-4 18 17 SPACE - SPACE 18 19 RECEPT. S18 S20 S21 1.26 50 8.32 S191316 COPIER 20 19 2 2 20 19 20 21 RECEPT. S34 REF .72 2 22 21 CU-6 4.16 30 40 6.66 CU-9 22 21 22 23 MICROWAVE S34 1.30 20 1.50 SMALL ALL S34 24 23 2 2 24 23 - 24 25 RECEPT. S34 ..90 1.50 SMALL ALL S34 26 25 CU-10 6.66 40 30 4.16 CU-7 26 25 26 27 MEZZ. RESTROOM9 1.16 1.26 RECEPT. S37 S36 28 27 2. 2 28 27 28 29 RECEPT. S39 S38 1.44 1.44 RECEPT. S40 S44 30 29 AH-11 8.32 50 40 6.66 CU-11 30 29 30 31 RECEPT. S42 1.44 20 1.26 RECEPT. S43 S44 S45 32 31 2 2 32 31 32 33 RECEPT. S46 1.08 20 SPACE 34 33 CU-8 4.16 30 30 4.16 CU-5 34 33 34 35 SPACE 36 35 2 2 36 35 36 37 38 37 SPACE SPACE 38 37 38 39 40 39 SPACE SPACE 40 39 40 41 SPACE SPACE 42 41 SPACE. SPACE 42 41 SPACE SPACE 42 REMARKS:CONNECTED LOAD: 48.1 KVA 134 AMPS REMARKS: CONNECTED LOAD: 129.1 KVA 358 AMPS REMARKS: CONNECTED LOAD: 13.4 KVA : 37 AMPS DEMAND LOAD: 36.9 KVA 102 AMPS DEMAND LOAD: 132.1 KVA 367 AMPS DEMAND LOAD. 16.8 KVA 47 AMPS PROVIDE HANDLE TIES FOR ALL MULTI-CIRCUIT� �j PROVIDE HANDLE TIES FOR ALL MULTI CIRCUIT HOMERUNS SHARING A NEUTRAL PER THE NATIONAL ELECTRIC CODE ARTICLE 210.4 SHARING A NEUTRAL PER THE NATIONAL ELECTRIC CODE ARTICLE 210.4 PROVIDE HANDLE TIES FOR ALL MULTI-CIRCUIT HOMERUNS SHARING A NEUTRAL PER THE NATIONAL ELECTRIC CODE ARTICLE 210.4 MULTIWIRE BRANCH CIRCUITS, PART (B) DISCONNECTING MEANS. DRAWINGS ARE DIAGRAMMATIC. WHERE THE CONTRACTOR MULTIWIRE BRANCH CIRCUITS, PART (B) DISCONNECTING MEANS. DRAWINGS ARE DIAGRAMMATIC. WHERE THE CONTRACTOR MULTIWIRE BRANCH CIRCUITS, PART B DISCONNECTING MEANS. DRAWINGS ARE DIAGRAMMATIC. WHERE THE CONTRACTOR Q) E O MODIFIES THE CIRCUITING, THE CONTRACTOR SHALL PROVIDE AN INDIVIDUAL NEUTRAL PER CIRCUIT, MULTI-POLE CIRCUIT BREAKERS, MODIFIES THE CIRCUITING, THE CONTRACTOR SHALL PROVIDE AN INDIVIDUAL NEUTRAL PER CIRCUIT, MULTI-POLE CIRCUIT BREAKERS, MODIFIES THE CIRCUITING, THE CONTRACTOR SHALL PROVIDE AN INDIVIDUAL NEUTRAL PER CIRCUIT, MULTI-POLE CIRCUIT BREAKERS OR CIRCUIT BREAKER HANDLE TIE TO MEET THE NEC ARTICLE. ALL COSTS ASSOCIATED WITH MODIFICATIONS SHALL BE INCLUDED IN OR CIRCUIT BREAKER HANDLE TIE TO MEET THE NEC ARTICLE. ALL COSTS ASSOCIATED WITH MODIFICATIONS SHALL BE INCLUDED IN OR CIRCUIT BREAKER HANDLE TIE TO MEET THE NEC ARTICLE. ALL COSTS ASSOCIATED WITH MODIFICATIONS SHALL BE INCLUDED IN a) THE CONTRACTOR'S BID. THE CONTRACTOR'S BID. THE CONTRACTOR'S BID.un cl) W a c VJ � Q ai N 0 co E � a tl UNIT PANEL FOR 1-BEDROOM UNIT UNIT PANEL FOR 2-BEDROOM UNIT FLUSH MOUNTINGFLUSH MOUNTING 10,000 AIC PANEL SCHEDULE 10,000 AIC PANEL SCHEDULE NO. UP LOCATION: 1-BEDROOM (678 SQ, FT.) 120/208 VOLTS 1P 3WIRE NO. UP LOCATION: 2-BEDROOM (986 SQ. FT.) 120/208 VOLTS 1P 3WIRE SERVING: UNIT 100 AMPS WITH MAIN LUGS SERVING: UNIT .100 AMPS WITH MAIN LUGS CKT LOAD DESCRIPTION KVA TRIP TRIP KVA LOAD DESCRIPTION CKT CKT LOAD DESCRIPTION KVA TRIP TRIP KVA LOAD DESCRIPTION CKT N0. AMPS AMPS NO. N0. AMPS AMPS N0. 1 RANGE 8.00 50 20 1.50 WASHER 1 2 1 RANGE 8.00 50 20 .1.50 WASHER 2 3 2 30 5.00 DRYER 4 3 2 30 5.00 DRYER 4 5 HEAT 1.75 15 2 6 5 HEAT 2.50 15 2 6 7 2 20 1.50 KITCHEN 8* 7 2 20 1.50 KITCHEN 8 9 GLL - ARC FAULT 1.50 20 20 1.50 KITCHEN 10 * * 9 GLL - ARC FAULT 1.50 20 20 1.50 KITCHEN 10 11 GLL -ARC FAULT 1.50 20 20 18 BATH GFI 12 * 11 GLL -ARC FAULT 1.50 20 20 18 BATH GFI 12 13 BED ARC FAULT 1.50 20 SPACE 14 * 13 BED ARC FAULT 1.50 20 20 .1.50 BED ARC FAULT 14 15 SPACE SPACE 16 15 SPACE SPACE 16 REMARKS: * PROVIDE ARC FAULT CIRCUIT CONNECTED LOAD: 23.7 KVA 114 AMPS REMARKS: * PROVIDE ARC FAULT CIRCUIT CONNECTED LOAD: 26.6 KVA 128 AMPS BREAKER DEMAND LOAD: 15.8 KVA 76 AMPS BREAKER DEMAND LOAD: 17.4 KVA 83 AMPS : n • 22 .40 NOTE. DEMAND LOAD CALCULATION PER NEC 220.40 .NOTE. DEMAND LOAD CALCULATION PER NEC 0 L W _ uj W � U w � z