HomeMy WebLinkAboutPermit EL16-1076 - TUKWILA VILLAGE / BUILDING D - SUITE A WIRINGTUKWILA VILAGE
BUILDING D
14400 TUKWILA
INTERNATIONAL BLVD
EXPIRED
12/04/17
ELl 6=1 076
City of Tukwila
• Department of Community Development
• 6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206-431-3670
Inspection Request Line: 206-438-9350
Web site: http://www.TukwilaWA.gov
Parcel No: 0040000180
ELECTRICAL PERMIT
Permit Number: EL16-1076
Address: 14400 TUKWILA INTERNATIONAL Issue Date: 12/6/2016
BLVD Permit Expires On: 6/4/2017
Project Name: TUKWILA VILLAGE BUILDING D
Owner:
Name: TUKWILA CITY OF
Address: 6200 SOUTHCENTER BLVD, TUKWILA,
WA, 98188
Contact Person:
2015
Name:
MITCH CHAMBERLIN
Address:
PO BOX 849, SUMNER, WA, 98390
Contractor:
2014
Name:
EVERGREEN STATE ELECTRIC INC
Address:
PO BOX 849, SUMNER, WA, 98390
License No:
EVERGSE066JA
Lender:
2015
Name:
2015
Address:
DESCRIPTION OF WORK:
WIRE ONE TENANT IMPROVEMENT IN SUITE W
Valuation of single family: $0.00
Valuation of mf/comm: $80,000.00
Type of Work: TENANT IMP
Phone: (253) 770-0656
Phone: (253) 770-0656
Expiration Date: 4/1/2018
Fees Collected: $1,776.00
Electrical Service Provided by: SEATTLE CITY LIGHT
Water District: 125
Sewer District: VALLEY VIEW
Current Codes adopted by the City of Tukwila:
International Building Code Edition:
2015
National Electrical Code:
2014
International Residential Code Edition:
2015
WA Cities Electrical Code:
2014
International Mechanical Code Edition:
2015
WAC 296-4613:
2014
Uniform Plumbing Code Edition:
2015
WA State Energy Code:
2015
International Fuel Gas Code:
2015
t
Permit Center Authorized Signature:
Date:
11,0
I hearby certify that I have read and examined this permit and know the same to be true and correct. All
provisions of law and ordinances governing this work will be complied with, whether specified herein or not.
The granting of this permit does not presume to give authority to violate or cancel the provisions of any other
state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this
development permit and agree to the conditions attached to this permit. /
Signature: �� it �c� Date:
Print Name:
This permit shall become null and void if the work is not commenced within 180 days for the date of issuance, or if
the work is suspended or abandoned for a period of 180 days from the last inspection.
PERMIT CONDITIONS:
<NONE>
PERMIT INSPECTIONS REQUIRED
Permit Inspection Line: (206) 438-9350
2100
ELECTRICAL FINAL
7003
ROUGH -IN ELECTRICAL
7002
SERVICE
7001
UNDERGROUND/SLAB
CITY OF TUKWi- .
Community Development Department
• t� Permit Center
6300 Southcenter Blvd., Suite 100
Tukwila, WA 98188
http://www.TukwilaWA.gov
SITE LOCATION
Electrical Permit No..j
Project No.
Date Application Accepted:
Date Application Expires:
MCI
ELECTRICAL PERMIT APPLICATION
Applications and plans must be complete in order to be accepted for plan review.
Applications will not be accepted through the mail or by fax.
"Please Print"
�q
'' II' /I , V"1 King Co Assessor's Tax No.:
Site Address: A DO -TU « TF IAV1 A1- &VO Suite Number:. Floor:
Tenant Name: //Vi�.t p-P�G11`it. - LNi1tiG New Tenant: Q ....Yes ❑..No
PROPERTY OWNER
Name: �VKw y -A YINa veri c
Address. ')q _ 27-&iJ- 50 UlG A sar
City: AkIA, State: Zip
LMA,
CONTACT PERSON — person receiving all
communication
project
Name: 1W tfCb, tq
Type of work:
Address:
Addition
❑ Low Voltage ❑
City:
State: WA.
Zip- 6�
Phone X3 -'7p_ .
Fax:
?6- /767
Email:
ELECTRICAL CONTRACTOR INFORMATION
Company Name:
Address:
City: State: Zip:
Phone: Fax:
Contr Reg No.: Exp Date:
Tukwila Business License No.;
Valuation of Project (contractor's bid price): $ i 0 U t amC_A,
Scope of Work (please provide detailed information): W 112.4- DiU T 17P.NAfff-
Will service be altered? ❑ Yes
Type of Use:
Type of work:
New ❑
Addition
❑ Low Voltage ❑
Generator
Property Served by:
❑ Puget Sound Energy
Wr
W
❑ Service Change
❑ Fire Alarm
Seattle City Light
H:\Applications\Forms-Applications On Line\2014 ApplicationsTlectrical Permit Application Revised 1-1-14.docx
Revised: July 2013
bh
Adding more than 50 amps? ❑ Yes
❑ Remodel
❑ Telecommunication
❑ No
PI/Tenant Improvement
❑ Temporary Service
Pagel of 2
RESIDENTIAL
NEW RESIDENTIAL SERVICE
❑ New single family dwellings ...................................$152.85
(including an attached garage)
❑ Garages, pools, spas and outbuildings ........................$81.90 ea
❑ Low voltage systems
(alarm, furnace thermostat).................................$59.85 ea
RESIDENTIAL REMODEL AND SERVICE CHANGES
❑
Service change or alteration .......................................$81.90
❑
(no added/altered circuits)
$80.90
❑
Service change with added/altered circuits.................$81.90
$86.25
number of added circuits .......................
$11.55 ea
❑
Circuits added/altered without service change ............
$54.60
(up to 5 circuits)
$10.80 ea
❑
Circuits added/altered without service change ............
$54.60
(6 or more circuits)...............................................$7.65
ea
❑
Meter/mast repair ........................................................$68.25
❑
Low voltage systems .................................................$59.85
(alarm, furnace thermostat)
PERMIT APPLICATION NOTES -
MULTI -FAMILY AND COMMERCIAL
Fees are based on the valuation of the electrical contract.
MISCELLANEOUS FEES
❑
Temporary service (residential) .................................. $65.00
❑
Temporary service (generator) ...................................
$80.90
❑
Manufactured/mobile home service ...........................
$86.25
(excluding garage or outbuilding)
❑
Carnivals....................................................................
$80.60
Number of concessions .........................
$10.80 ea
Each ride and generator.truck................$10.80
ea
***EFFECTIVE JANUARY 1, 2014
EACH PERMIT WILL BE ASSESSED A
5% TECHNOLOGY FEE***
Value of Construction – In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject
to possible revision by the Permit Center to comply with current fee schedules.
Expiration of Plan Review – Applications for which no permit is issued within 180 days following the date of application shall expire by limitation
The Building Official may grant one extension of time for an additional period not to exceed 90 days. The extension shall be requested in writing
and justifiable cause demonstrated.
I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER
PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT.
BUILDING OWNER OR ELECTRICAL CONTRACTOR:
Date: /1-,93'16
Print Name: (�� o /7L'��`i� Day Telephone:,2 5-3 &_16 19 12—
Mailing Address: �T f 7(AL 'Iz�.� 4t16 49TJ _3w
City State Zip
H:\ApplicationsTorms-Applications On Line\2014 ApplicationsTlectrical Permit Application Revised 1-1-14.docx
Revised: July 2013
bh
Page 2 of 2
Date Paid: Wednesday, November 23, 2016
Paid By: EVERGREEN STATE ELECTRIC
Pay Method: CHECK 1070
Printed: Wednesday, November 23, 2016 10:37 1 of 1 �'r—jf fl
SYSTEMS
AM
DESCRIPTIONS • QUANTITY
PAID
PermitTRAK
$1,434.46
EL16-1076 Address: 14400 TUKWILA INTERNATIONAL BLVD Apn: 0040000180
$1,434.46
ELECTRICAL
$1,366.15
PERMIT FEE MULTI-FAM/COMM R000.322.101.00.00 0.00
$1,366.15
TECHNOLOGY FEE
$68.31
TECHNOLOGY FEE R000.322.900.04.00 0.00
TOTAL PAID BY RECEIPT:....
$68.31
i
Date Paid: Tuesday, December 06, 2016
Paid By: EVERGREEN REFRIGERATION
Pay Method: CHECK 1073
Printed: Tuesday, December 06, 2016 2:49 PM 1 of 1 (r—P
SYSTEMS
2015 Washington State Energy Code Compliance Forms for Commercial Buildings including R2, R3, R4 over
Project Title:
Tukwila Bldg. D Tenant Improvement
Date 10/3/2016
Calculation
Area NOTE 8
O Addition - O Addition
stand alone + existing
Q Spaces where < 50% of 0 Spaces where >_ 50% of O
luminaires are replaced luminaires are replaced
For Building Department Use
LPA
Calculation
Type
• Standard O Additional Efficiency Package Option O
C406.3 Reduced Interior Lighting Power
To comply vuth C406.3, the Proposed LPD shall be 25% /ovier than the Target LPA.
Refer to C406.3 for additional requirements.
Maximum Allowed Lighting WattagWTE ,
576
Building Area
Location (plan #, Gross Interior
room #, or ALL) Area Description Area in ff
Allowed Watts Allowec
Watts per ff (watts/ff x area)
Office
Tenant Improvement Office Area 24100
0.66 15906
LED Downlight
32
15
480
Office
2x4 LED Troffer
62
45
2790
Office
1'x4' LED Troffer
13
30
390
Office
Linear, LED, Recessed (5 watts per foot)
1066
5
Total 24100
Proposed Lighting Wattage
Building Area
Location (plan #,
room #) Fixture Description NOTE 2, 3, 4, 5
Number of
Fixtures
Watts per
Fixture NOTE 6
Watts Proposed
Office
2 -Lamp, T8, Fluorescent Surface Mount
9
64
576
Office
2 -Lamp, T8, Fluorescent Wall Mount
2
64
128
Office
LED Downlight
32
15
480
Office
2x4 LED Troffer
62
45
2790
Office
1'x4' LED Troffer
13
30
390
Office
Linear, LED, Recessed (5 watts per foot)
1066
5
5330
Office
LED Exit Sign
9
3
27
Compliance by Building Area "OTE'
Building Area
Warnings
Total Allowed
Watts
Total Proposed
Watts
Interior Lighting
Power Allowance
Office
15906
9721
COMPLIES
Note 1 - List all unique building areas per Table C405.4.2(1) that occur in the Totalsl 15906 1 9721
, project scope. Select building area category from drop doW7 menu.
Note 2 - Proposed fixtures must be listed in the building area in Mich they occur. List all proposed lighting fixtures including exempt
lighting equipment and existing -to -remain fixtures.
Note 3 - For proposed Fixture Description, indicate fixture type, lamp type (e.g. T-8), numberof lamps in the fixture, and ballast type (if
included).
For track lighting, list the length of the track (in feet) in addition to the fixture, lamp, and ballast information.
Note 4 - For lighting equipment eligible for exemption per C405.4.1, note exception number and leave Watts/Fixture blank.
Note 5 - Existing -to -remain fixtures shall be included in the Proposed Lighting Wattage table in the same manner as new fixtures. Identify as
existing in fixture description.
Note 6 - For proposed Watts/Fixture enter the luminaire v attage for installed lamp and ballast using manufacturer or other approved source.
For
City of Tukwila
Department of Community Development
11/2/2017
MITCH CHAMBERLIN
PO BOX 849
SUMNER, WA 98390
RE: Permit No. EL16-1076
TUKWILA VILLAGE BUILDING D
14400 TUKWILA INTERNATIONAL BLVD
Dear Permit Holder:
Allan Ekberg, Mayor
Jack Pace, Director
In reviewing our current records, the above noted permit has not received a final inspection by the City of Tukwila Building
Division. Per the International Building Code, International Mechanical Code, Uniform Plumbing Code and/or the National Electric
Code, every permit issued by the Building Division under the provisions of these codes shall expire by limitation and become null
and void if the building or work authorized by such permit has not begun within 180 days from the issuance date of such permit, or if
the building or work authorized by such permit is suspended or abandoned at any time after the work has begun for a period of 180
days. Your permit will expire on 12/4/2017.
Based on the above, you are hereby advised to:
1) Call the City of Tukwila Inspection Request Line at 206-438-9350 to schedule for the next or final inspection. Each
inspection creates a new 180 day period, provided the inspection shows progress.
-or-
2) Submit a written request for permit extension to the Permit Center at least seven(7) days before it is due to expire.
Address your extension request to the Building Official and state your reason(s) for the need to extend your permit.
The Building Code does allow the Building Official to approve one extension of up to 180 days. If it is determined that your
extension request is granted, you will be notified by mail.
In the event you do not call for an inspection and/or receive an extension prior to 12/4/2017, your permit will become null and void
and any further work on the project will require a new permit and associated fees.
Thank you for your cooperation in this matter.
Sincerely, A- —PJ
Bill Rambo
Permit Technician
File No: ELI 6-1076
6300 Southcenter Boulevard Suite #100 9 Tukwila, Washington 98188 • Phone 206-431-3670 • Fax 206-431-3665
May 9, 2017
City of Tukwila
Department of Community Development - Jack Pace, Director
Francine Boyd
Evergreen State Electric
PO Box 849
Sumner, WA 98390
RE: Request for Extension #1
Permit Number EL16-1076
Dear Ms. Boyd,
Allan Ekberg, Mayor
This letter is in response to your written request for an extension to Permit EL16-1076. The Building
Official, Jerry Hight, has reviewed your letter and considered your request to extend the above
referenced permit. It has been determined that the City of Tukwila Building Division will be granting an
extension to the permit through December 4, 2017.
If you should have any questions, please contact our office at (206) 431-3670.
Sincerely,
Bill Rambo
Permit Technician
File: Permit No. ELI 6-1076
Tukwila City Hall • 6200 Southcenter Boulevard • Tukwila, WA 98188 • 206-433-1800 • Website: TukwilaWA.gov
05/08/2017 MON 10:08 FAX 2! 70 1767 Evergreen State Electric
9�/,I AFONJJEJEW
'LEC TR /C
Rdrldentlal a Comm orclel a lndusWal iAlarm
To: City of Tukwila Permit Counter
RE: Permit # EL16-1076
Tukwila Village Building D Tenant Improvement
34400 Tukwila International Blvd.
05/08/2017
/0001/002
Mello,
I would like to aslc for an extension on permit #EL16-1076 we are still in progress
with the building and cannot call in any inspection at this time. This particular
building is being built at this time and we have not done any electrical work yet at
this location.
Thank You,
Francine Boyd Q!o-- 6-T)Y'6��
Permit
Specialist
Evergreen State Electric, Inc.
Request for
/_Extension #
Current Expiration Date: 6
Extension Request:
Approved for _ 1 days
❑ Denied (provide explanation)
Signature/initials
I
RECEIVED
CITY OF TUKWILA
MAY 0 8 2011
PERMIT CENTER
P.O. Box 849, Sumner, Wa®hln pn 98390 • (263) 7700M • 1.600.4914936 • FAX (259) 770.1767
5/1/2017
City of Tukwila Allan Ekberg, Mayor
Department of Community Development Jack Pace, Director
MITCH CHAMBERLIN
PO BOX 849
SUMNER, WA 98390
RE: Permit No. ELI 6-1076
pTUKWILA VILLAGE BUILDING D
14400 TUKWILA INTERNATIONAL BLVD
Dear Permit Holder:
In reviewing our current records, the above noted permit has not received a final inspection by the City of Tukwila Building
Division. Per the International Building Code, International Mechanical Code, Uniform Plumbing Code and/or the National Electric
Code, every permit issued by the Building Division under the provisions of these codes shall expire by limitation and become null
and void if the building or work authorized by such permit has not begun within 180 days from the issuance date of such permit, or if
the building or work authorized by such permit is suspended or abandoned at any time after the work has begun for a period of 180
days. Your permit will expire on 6/4/2017.
Based on the above, you are hereby advised to:
1) Call the City of Tukwila Inspection Request Line at 206-438-9350 to schedule for the next or final inspection. Each
inspection creates a new 180 day period, provided the inspection shows progress.
-or-
2) Submit a written request for permit extension to the Permit Center at least seven(7) days before it is due to expire.
Address your extension request to the Building Official and state your reason(s) for the need to extend your permit.
The Building Code does allow the Building Official to approve one extension of up to 180 days. If it is determined that your
extension request is granted, you will be notified by mail.
In the event you do not call for an inspection and/or receive an extension prior to 6/4/2017, your permit will become null and void
and any further work on the project will require a new permit and associated fees.
Thank you for your cooperation in this matter.
Sincerely,
Bill Rambo
Permit Technician
File No: ELI 6-1076
6300 Southcenter Boulevard Suite #100 9 Tukwila, Washington 98188 • Phone 206-431-3670 0 Fax 206-431-3665
vERMIT COORD COP`S:
PLAN REVIEW/ROUTING SLIP
PERMIT NUMBER: EL16-1076 DATE: 11/23/16
PROJECT NAME: TUKWILA VILLAGE BUILDING D - SUITE 1
SITE ADDRESS: 14400 TUKWILA INTERNATIONAL BLVD
X Original Plan Submittal
Response to Correction Letter #
DEPARTMENTS:
wv-
Building Division
Revision # before Permit Issued
Revision # after Permit Issued
Fire Prevention ❑ Planning Division ❑
Public Works ❑ Structural ❑ Permit Coordinator
PRELIMINARY REVIEW: - DATE: 11/24/16
Not Applicable ❑ Structural Review Required ❑
(no approval/review required)
REVIEWER'S INITIALS:
APPROVALS OR CORRECTIONS:
DATE:
DUE DATE: 12/22/16
Approved ❑ Approved with Conditions ❑
Corrections Required ❑ Denied ❑
(corrections entered in Reviews) (ie: Zoning Issues)
Notation:
REVIEWER'S INITIALS:
DATE:
Permit Center Use Only
CORRECTION LETTER MAILED:
Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials:
12/18/2013
EVERGREEN STATE ELECTRIC r ` Page 1 of 3
Home ESpanol Contact Search L&I
A-7, Index Help a1y Im
Safety & Health Claims & Insurance Workplace Rights Trades & Licensing
Washington State Department of
JI-abor & Industries
EVERGREEN STATE ELECTRIC INC
Owner or tradesperson PO BOX 849
SUMNER, WA 98390
Principals 253-770-0656
CHAMBERLIN, MITCHELL, PRESIDENT PIERCE County
CHAMBERLIN, LYNDA K, VICE PRESIDENT
CHAMBERLIN, LYNDA, AGENT
WILKINSON, JESSICA, SECRETARY
(End: 12/26/2012)
Doing business as
EVERGREEN STATE ELECTRIC INC
WA UBI No. Business type
601 521 666 Corporation
Governing persons
LYNDA
K
CHAMBERLIN
MITCHELL D CHAMBERLIN;
License
Verify the contractor's active registration / license / certification (depending on trade) and any past violations.
Electrical Contractor Active.
.......................................................... .
Meets current requirements.
License specialties
GENERAL
License no.
EVERGSE066JA
Effective — expiration
04/01/1994— 04/01/2018
Designated administrator
Active.
CHAMBERLIN, MITCHELL
Meets current requirements.
License type
License no.
Master Electrician
CHAMBM*977KG
Bond
............
Contractors Bonding & Insurance Co
$4,000.00
Bond account no.
SJ5622
Received by L&I
Effective date
04/24/2012
04/01/2012
Expiration date
Until Canceled
Bond history
Savings
No savings accounts during the previous 6 year period. Help us improve
https:Hsecure.Ini.wa.gov/verify/Detail.aspx?UBI=601521666&LIC=EVERGSE066JA&SAW= 12/6/2016
ELECTRICAL SYMBOLS LEGEND
A DETAIL/SECTION IDENTIFICATION: A = DETAIL/SECTION LETTER, B = SHEET NUMBER S LIGHT SWITCH TOGGLE TYPE, SINGLE POLE, SUBSCRIPTS; 3 =THREE WAY, 4 =
B WHERE DETAIL/SECTION IS DRAWN. FOUR WAY, D = DIMMER CONTROL, K KEY OPERATED, P = PILOT LIGHT, a, b, c,
A EQUIPMENT CONNECTION CALLOUT. A,13EQUAL EQUIPMENT IDENTIFICATION ON ETC = NUMBER OF SWITCHES AT THE LOCATION AND SPECIFIC FIXTURES
B
CONTROLLED. MOUNT AT 42 INCHES AFF.
MECHANICAL EQUIPMENT CONNECTION SCHEDULES. VERIFY EXACT EQUIPMENT
REQUIREMENTS ON SHOP DRAWING EQUIPMENT SUBMITTALS PRIOR TO ROUGH -IN. DO NO
ROUGH -IN FOR EQUIPMENT PRIOR TO REVIEW OF SUBMITTALS. REPORT ANY - DISCONNECT SWITCH
TO ENGINEER IN
DIFFERENCES IN REQUIREMENTS WRITING..
F
USED DISCONNECT SWITCH WITH FUSES:
CONDUIT CONCEALED. HASH MARKS INDICATE NUMBER OF #12 CONDUCTORS IN CODE
SIZE CONDUIT. NO HASH MARKS INDICATES 2412 CONDUCTORS PLUS GROUND IN 3/4 Sm MOTOR RATED TOGGLE SWITCH WiTH OVERLOAD HEATER(S), SIZE PER NEC AND
CONDUIT, LONG HASH MARKS INDICATES NEUTRAL CONDUCTOR. INDICATES GROUND MANUFACTURERS REQUIREMENTS.
CONDUCTOR.
2
0
FLUSH MOUNTED DUAL TELEPHONE/DATA OUTLET, MOUNT AT 18" AFF. PROVIDE
f
NON-METALLIC SHEATHED CABLE 1212 CU WITH GROUND
.4-11/16" SQUARE BOX WITH 1-1/4" CONDUIT.AND PULL STRING TO ACCESSIBLE
f3
NON-METALLIC SHEATHED CABLE 12/3 CU WITH GROUND
CEILING SPACE.
FLEXIBLE RACEWAY, PROVIDE GROUND CONDUCTCRS PER NEC.
QT
TRANSFORMER. SIZE AND TYPE AS NOTED. PROVIDE GROUNDING AS REQUIRED
BY NEC.
-�-
A-1,3 ADJACENT TO ARROW INDICATES HOMERUN OF CONDUCTORS IN CONDUIT FOR
CIRCUITS 1 AND 3 TO PANEL "A••
_
GROUND PER NEC
- EXIT LIGHT WITH BATTERY, UNIVERSAL MOUNTING.
SC
`COMBINATION SMOKE/ CARBON MONOXIDE DETECTOR WITH. SOUNDER BASE
EMERGENCY FLOODLIGHT WITH BATTERY.
PS
DAYLIGHT PHOTOSENSOR. 0-10V WITH DUAL OUTPUT AND POWER PACK.
0
LIGHT FIXTURE, SURFACE MOUNTED ON CEILING., 2 -LAMP, T8, WRAPAROUND, 64 WATTS
(E)
EXISTING
LIGHT FIXTURE, 2'X 4', RECESSED, LED, 45 WATTS
IAID
IA/CATUMD00nnc
O
u
Ln
bp.
N
L!J
N
O
i
O
h
�I
in
CL
v
0
i
ro
n.
a
0
u
v
A
v
E
m
0
N
M
0
L:�
v
( 6.3
L 1 LIGHTING P"LAN
N
SCALE: 1/8"=1'-0"
SCALE: 1/8"=1'-0" .
V.
CL
SCALE: 1/8"=1'-0"
�!
V
m>,
o sr
m.
w
N
i
tp
0
tl
in .
0029060
NAL
10/3/16
SCALE: AS NOTED'
DATE: SHEET
10-3-16
DRAWN Y:
JAE 01
CHECKED BY: E31
SLH/GLW
JOB NO.: OF
16-072 -
0
a
SCALE: 1/8"=l' -O" J
PULL
SECT.
800A
•®'O
O
•®O
•®
■Q
yr
O
�O
0
■Q
•®
•®
0.0
®•®
100A
� '. ■M
00000000
■M
��,
■M
M
■M
M
■M
M
s
■M
0000000®
■M
M
■M
M
■M
M
■
PULL
■®•®
®•®
®•®
®•®
sECT.00000000
■M
■M
M
•M
M
■M
M
•M
800A
•®
•®
®•®
®•®
®•O
100A, 208V; 1 PH, PSE METER AND
METER BASE WITH 100A/2 -POLE
4TH FLOOR
CIRCUIT BREAKERS. KE S. TYPICAL OF 40.
PULL
SECT.
800A
•®'O
O
•®O
•®
■Q
•O
O
�O
0
■Q
•®
•®
0.0
®•®
100A, 208V, 1 PH, PSE METER AND
METER BASE WITH 100Al2-POLE
2ND FLOOR _ _ _ CIRCUIT BREAKERS' TYPICAL OF 28.
SURFACE MOUNTING SURFACE MOUNTING SURFACE MOUNTING
PANEL SCHEDULE PANEL SCHEDULE -PANEL SCHEDULE
22,000 AIC 22 000 AIC 22 000 AIC
NO. LOCATION: ' TENANT SPACE 120/208 VOLTS 3PHASE 4WIRE No LOCATION: TENANT SPACE 120/208 VOLTS 3PHASE 4WIRE No LOCATION: TENANT SPACE 120/208 VOLTS 3PHASE 4WIRE
T1 T2 T3
SERVING. TENANT SPACE 200 AMPS WITH MAIN LUGS SERVING. TENANT SPACE 400 AMPS WITH MAIN LUGS SERVING: TENANT SPACE 200 AMPS WITH MAIN LUGS
CKT TRIP TRIP CKT CKT TRIP TRIP CKT CKT TRIP TRIP CKT
No, LOAD DESCRIPTION KVA AMPS AMPS KVA LOAD DESCRIPTION No. No. LOAD DESCRIPTION KVA AMPS AMPS KVA LOAD DESCRIPTION No. No. LOAD DESCRIPTION KVA KVA LOAD DESCRIPTION k .
AMPS AMPS N0,
1 RECEPT. OFFICE 902 SO3 1.26 20 20 1.26 RECEPT. OFFICE SO1 SO4 2 1 AH-3 11.90 60 60 11.19 AH-4 2 1 S02 SO3 SO4 SO5 CORR. LTS .78 20 20 .64 SHAG OFF. S31 S30 COR. LTS 2
3 RECEPT. OFFICE S32 1.62 1.70 R.R.IRECEPT. OFFICE S05 4 3 2 2 4 3 LOBBY ENTRY LIGHTS 66 .81 WORK RM. S06 COR. LIGHTS 4'
5 RECEPT. OFFICE S31 S32 1.44 1.62 RECEPT: S29 S28 6 5 AH-6 8.32 50 50 8.32 AH-7 6 5 REC. U-SHAPED TRACK 1.30 .95 CORRIDOR STRIP LIGHTING 6
7 RECEPT. OFFICE S06 S27 1.26 1.50 RECEPT. 06 EQUIP. 8 7 2 2 8 F13
OFFICE x 11 LIGHTS .80 .38 OFFICE x 2 CORRIDOR LTS 8 t.:
9 RECEPT. OFFICE 909 SO8 1.44 1.26 RECEPT. S26 10 9 AH-8 8.32 56 60 11.19 AH-5 10 S46 S45 S44 S43 CORR. LTS .80 1.00 OPEN OFFICE LIGHTS
10
RECEPT. S24 .90 1.08 RECEPT. S25 S25A 12 11 - 2 2 12 CONF. S38 CORRIDOR LTS_
11 71 1.00 TRAINING S26 LIGHTS 12
13 AH-10 8.32 50 50 8.32 AH-9
13 RECEPT. S24 90 1.44 RECEPT. S22 S23 14 14 BOARD ROOM LIGHTS 80 .81 JAN S35 LUNCH COR. LTS 14
15 RECEPT. S10 S13 Sl l 1.62 1.62 RECEPT. 14,1516 15 2 2 16 15 SHAG OFFICE S32 1.00 20 20 1.00 PRODUCTION S25 LIGHTS 16
17 RECEPT. S16 S-17 1.08 20 1.50 S19 SPECIAL EQUIP. 18 17 CU-3 4.16 30 30 4.16 CU-4 18 17 SPACE - SPACE 18
19 RECEPT. S18 S20 S21 1.26 50 8.32 S191316 COPIER 20 19 2 2 20 19 20
21 RECEPT. S34 REF .72 2 22 21 CU-6 4.16 30 40 6.66 CU-9 22 21 22
23 MICROWAVE S34 1.30 20 1.50 SMALL ALL S34 24 23 2 2 24 23 - 24
25 RECEPT. S34 ..90 1.50 SMALL ALL S34 26 25 CU-10 6.66 40 30 4.16 CU-7 26 25 26
27 MEZZ. RESTROOM9 1.16 1.26 RECEPT. S37 S36 28 27 2. 2 28 27 28
29 RECEPT. S39 S38 1.44 1.44 RECEPT. S40 S44 30 29 AH-11 8.32 50 40 6.66 CU-11 30 29 30
31 RECEPT. S42 1.44 20 1.26 RECEPT. S43 S44 S45 32 31 2 2 32 31 32
33 RECEPT. S46 1.08 20 SPACE 34 33 CU-8 4.16 30 30 4.16 CU-5 34 33 34
35 SPACE 36 35 2 2 36 35 36
37 38 37 SPACE SPACE 38 37 38
39 40 39 SPACE SPACE 40 39 40
41 SPACE SPACE 42 41 SPACE. SPACE 42 41 SPACE SPACE 42
REMARKS:CONNECTED LOAD: 48.1 KVA 134 AMPS REMARKS: CONNECTED LOAD: 129.1 KVA 358 AMPS REMARKS: CONNECTED LOAD: 13.4 KVA : 37 AMPS
DEMAND LOAD: 36.9 KVA 102 AMPS DEMAND LOAD: 132.1 KVA 367 AMPS
DEMAND LOAD. 16.8 KVA 47 AMPS
PROVIDE HANDLE TIES FOR ALL MULTI-CIRCUIT� �j
PROVIDE HANDLE TIES FOR ALL MULTI CIRCUIT HOMERUNS SHARING A NEUTRAL PER THE NATIONAL ELECTRIC CODE ARTICLE 210.4 SHARING A NEUTRAL PER THE NATIONAL ELECTRIC CODE ARTICLE 210.4 PROVIDE HANDLE TIES FOR ALL MULTI-CIRCUIT HOMERUNS SHARING A NEUTRAL PER THE NATIONAL ELECTRIC CODE ARTICLE 210.4
MULTIWIRE BRANCH CIRCUITS, PART (B) DISCONNECTING MEANS. DRAWINGS ARE DIAGRAMMATIC. WHERE THE CONTRACTOR MULTIWIRE BRANCH CIRCUITS, PART (B) DISCONNECTING MEANS. DRAWINGS ARE DIAGRAMMATIC. WHERE THE CONTRACTOR MULTIWIRE BRANCH CIRCUITS, PART B DISCONNECTING MEANS. DRAWINGS ARE DIAGRAMMATIC. WHERE THE CONTRACTOR Q) E
O
MODIFIES THE CIRCUITING, THE CONTRACTOR SHALL PROVIDE AN INDIVIDUAL NEUTRAL PER CIRCUIT, MULTI-POLE CIRCUIT BREAKERS, MODIFIES THE CIRCUITING, THE CONTRACTOR SHALL PROVIDE AN INDIVIDUAL NEUTRAL PER CIRCUIT, MULTI-POLE CIRCUIT BREAKERS, MODIFIES THE CIRCUITING, THE CONTRACTOR SHALL PROVIDE AN INDIVIDUAL NEUTRAL PER CIRCUIT, MULTI-POLE CIRCUIT BREAKERS
OR CIRCUIT BREAKER HANDLE TIE TO MEET THE NEC ARTICLE. ALL COSTS ASSOCIATED WITH MODIFICATIONS SHALL BE INCLUDED IN OR CIRCUIT BREAKER HANDLE TIE TO MEET THE NEC ARTICLE. ALL COSTS ASSOCIATED WITH MODIFICATIONS SHALL BE INCLUDED IN OR CIRCUIT BREAKER HANDLE TIE TO MEET THE NEC ARTICLE. ALL COSTS ASSOCIATED WITH MODIFICATIONS SHALL BE INCLUDED IN a)
THE CONTRACTOR'S BID. THE CONTRACTOR'S BID. THE CONTRACTOR'S BID.un cl)
W a c
VJ �
Q ai
N
0
co E �
a
tl
UNIT PANEL FOR 1-BEDROOM UNIT UNIT PANEL FOR 2-BEDROOM UNIT
FLUSH MOUNTINGFLUSH MOUNTING
10,000 AIC PANEL SCHEDULE 10,000 AIC PANEL SCHEDULE
NO. UP LOCATION: 1-BEDROOM (678 SQ, FT.) 120/208 VOLTS 1P 3WIRE NO. UP LOCATION: 2-BEDROOM (986 SQ. FT.) 120/208 VOLTS 1P 3WIRE
SERVING: UNIT 100 AMPS WITH MAIN LUGS SERVING: UNIT .100 AMPS WITH MAIN LUGS
CKT LOAD DESCRIPTION KVA TRIP TRIP KVA LOAD DESCRIPTION CKT CKT LOAD DESCRIPTION KVA TRIP TRIP KVA LOAD DESCRIPTION CKT
N0. AMPS AMPS NO. N0. AMPS AMPS N0.
1 RANGE 8.00 50 20 1.50 WASHER 1 2 1 RANGE 8.00 50 20 .1.50 WASHER 2
3 2 30 5.00 DRYER 4 3 2 30 5.00 DRYER 4
5 HEAT 1.75 15 2 6 5 HEAT 2.50 15 2 6
7 2 20 1.50 KITCHEN 8* 7 2 20 1.50 KITCHEN 8
9 GLL - ARC FAULT 1.50 20 20 1.50 KITCHEN 10 * * 9 GLL - ARC FAULT 1.50 20 20 1.50 KITCHEN 10
11 GLL -ARC FAULT 1.50 20 20 18 BATH GFI 12 * 11 GLL -ARC FAULT 1.50 20 20 18 BATH GFI 12
13 BED ARC FAULT 1.50 20 SPACE 14 * 13 BED ARC FAULT 1.50 20 20 .1.50 BED ARC FAULT 14
15 SPACE SPACE 16 15 SPACE SPACE 16
REMARKS: * PROVIDE ARC FAULT CIRCUIT CONNECTED LOAD: 23.7 KVA 114 AMPS REMARKS: * PROVIDE ARC FAULT CIRCUIT CONNECTED LOAD: 26.6 KVA 128 AMPS
BREAKER DEMAND LOAD: 15.8 KVA 76 AMPS BREAKER DEMAND LOAD: 17.4 KVA 83 AMPS
:
n
• 22 .40 NOTE. DEMAND LOAD CALCULATION PER NEC 220.40
.NOTE. DEMAND LOAD CALCULATION PER NEC 0 L
W _
uj
W � U
w
� z