Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Permit EL16-1083 - BOEING / SE PARKING LOT - TEMPORARY SERVICE, LIGHTING AND GROUND
BOEING SE PARKING LOT 8123 E MARGINAL WAY S EL16-1083 City of Tukwila • Department of Community Development • 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Inspection Request Line: 206-438-9350 Web site: http://www.TukwilaWA.Rov ELECTRICAL:PERMIT Parcel No: 3324049002 Permit Number: EL16-1083 Address: 8123 E MARGINAL WAY S Issue Date: 12/12/2016 Permit Expires On: 6/10/2017 Project Name: BOEING - SE PARKING LOT Owner: Name: BOEING COMPANY THE Address: PO BOX 3707 M/C 20-00 PROPERTY Address: "I , DESCRIPTION OF WORK: Phone: (425) 814-6000 Phone: (425) 814-6000 Expiration Date: 1/30/2017 ADD TEMPORARY SERVICE (10 YEARS) TO POWER DISTRIBUTION, LIGHTING & GROUND NECESSARY FOR 8 TEMPORARY PARKING STALLS PLUS TEMP POWER TO 1 CREW TRAILER. Valuation of single family: $0.00 Fees Collected: $2,698.34 Valuation of mf/comm: $135,000.00 Type of Work: TENANT IMP Electrical Service Provided by: SEATTLE CITY LIGHT Water District: SEATTLE,TUKWILA Sewer District: SEATTLE,TUKWILA Current Codes adopted by the City of Tukwila: International Building Code Edition: TAX DEPT, SEATTLE, WA, 98124 Contact Person: 2014 Name: JEFFREY MCNEAL Address: 15135 NE 92 ST, REDMOND, WA, International Mechanical Code Edition: 98052 Contractor: 2014 Name: SEQUOYAH ELECTRIC LLC Address: 15135 NE 92ND ST, REDMOND, WA, International Fuel Gas Code: 98052-3519 License No: SEQUOEL977S9 Lender: Name: Address: "I , DESCRIPTION OF WORK: Phone: (425) 814-6000 Phone: (425) 814-6000 Expiration Date: 1/30/2017 ADD TEMPORARY SERVICE (10 YEARS) TO POWER DISTRIBUTION, LIGHTING & GROUND NECESSARY FOR 8 TEMPORARY PARKING STALLS PLUS TEMP POWER TO 1 CREW TRAILER. Valuation of single family: $0.00 Fees Collected: $2,698.34 Valuation of mf/comm: $135,000.00 Type of Work: TENANT IMP Electrical Service Provided by: SEATTLE CITY LIGHT Water District: SEATTLE,TUKWILA Sewer District: SEATTLE,TUKWILA Current Codes adopted by the City of Tukwila: International Building Code Edition: 2015 National Electrical Code: 2014 International Residential Code Edition: 2015 WA Cities Electrical Code: 2014 International Mechanical Code Edition: 2015 WAC 296-468: 2014 Uniform Plumbing Code Edition: 2015 WA State Energy Code: 2015 International Fuel Gas Code: 2015 Permit Center Authorized Signature: Date: I hearby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this development permit and agree to the conditions attached to this permit. Signa ` C L Date: 1 '(0 Print e: This permit shall become null and void if the work is not commenced within 180 days for the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. PERMIT CONDITIONS: <NONE> PERMIT INSPECTIONS REQUIRED Permit Inspection Line: (206) 438-9350 2100 ELECTRICAL FINAL 7003 ROUGH -IN ELECTRICAL 7002 SERVICE 7001 UNDERGROUND/SLAB CITY OF TUKWI__ I Community Development Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 h!tp://www.TukwilaWA.2o v SITE LOCATION Electrical Permit No. Project No. l Date Application Accepted: Date Application Expires: } % use ELECTRICAL PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. "Please Print" King Co Assessor's Tax No.: Site Address: 812TE. Marginal Way S - SE Parking Lot Suite Number: Floor: Tenant Name: Boeing New Tenant: ❑ .....Yes O ..No PROPERTY OWNER Name: The Boeing Company Address: PO Box 3707 M/C 20-200 Property City: Seattle State: WA Zip: 98124 CONTACT PERSON — person receiving all project communication Name: Jeffrey McNeal Address: 15135 NE 92nd Street City: Redmond State: WA Zip: 98052 Phone: (425) 766-3414 Fax: (425) 814-6003 Email: Valuation of Project (contractor's bid price): $ 135,000 ELECTRICAL CONTRACTOR INFORMATION Company Name: Sequoyah Electric LLC Address: 15135 NE 92nd St City: Redmond State: WA Zip: 98052 Phone: (425) 814-6000 Fax: (425) 814-6003 Contr Reg No.: SEQUOEL977 Exp Date: 12/31/2016 Tukwila Business License No.; 0994355 Scope of Work (please provide detailed information): Add temporary service to power distribution, lighting & Grid. necessary for 8 temporary airplane parking stalls plus temop power to 1 crew trailer. Will service be altered? GZ Yes ❑ No Type of Use: Temp Power to construction camp Type of work: 0 New ❑ Addition ❑ Service Change ❑ Low Voltage ❑ Generator ❑ Fire Alarm Property Served by: ❑ Puget Sound Energy 0 Seattle City Light H:\Applications\Forms-Applications On Line\2014 Applications\Electrical Permit Application Revised 1-1-14.docx Revised: January 2014 bh Adding more than 50 amps? ❑ Remodel ❑ Telecommunication Z Yes ❑ No ❑ Tenant Improvement 0 Temporary Service Pagel of 2 RESIDENTIAL NEW RESIDENTIAL SERVICE ❑ New single family dwellings ................................... $152.85 (including an attached garage) ❑ Garages, pools, spas and outbuildings ........................ $81.90 ea ❑ Low voltage systems (alarm, furnace thermostat) ................................ $59.85 ea RESIDENTIAL REMODEL AND SERVICE CHANGES ❑ Service change or alteration ...................................... $81.90 ❑ (no added/altered circuits) $80.90 ❑ Service change with added/altered circuits ................. $81.90 number of added circuits ....................... $11.55 ea ❑ Circuits added/altered without service change ........... $54.60 (up to 5 circuits) $10.80 ea ❑ Circuits added/altered without service change ........... $54.60 (6 or more circuits) ............................................... $7.65 ea ❑ Meter/mast repair ....................................................... $68.25 ❑ Low voltage systems ................................................. $59.85 (alarm, furnace thermostat) PERMIT APPLICATION NOTES - MULTI -FAMILY AND COMMERCIAL Fees are based on the valuation of the electrical contract. MISCELLANEOUS FEES ❑ Temporary service (residential) ................................. $65.00 ❑ Temporary service (generator) ................................... $80.90 ❑ Manufactured/mobile home service ........................... $86.25 (excluding garage or outbuilding) ❑ Carnivals....................................................................$80.60 Number of concessions ......................... $10.80 ea Each ride and generator truck ............... $10.80 ea ***EFFECTIVE JANUARY 1, 2014 EACH PERMIT WILL BE ASSESSED A 5% TECHNOLOGY FEE* * * Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation The Building Official may grant one extension of time for an additional period not to exceed 90 days. The extension shall be requested in writing and justifiable cause demonstrated. I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER OR ELECTRICAL CONTRACTOR: Signature: Date: 11/29/2016 Print Name: Jeffrey McNeal Day Telephone: (425) 766-3414 Mailing Address: 15135 NE 92nd St. Redmond WA 98052 City State Zip H:\Applications\Forms-Applications On Line\2014 Applications0ectrical Permit Application Revised 1-1-14.docx Revised: January 2014 bh Page 2 of 2 DESCRIPTIONS PermitTRAK ACCOUNT QUANTITY PAID $2,698.34 EL16-1083 Address: 8123 E MARGINAL WAY S Apn: 3324049002 $2,698.34 ELECTRICAL $2,594.56 PERMIT FEE MULTI-FAM/COMM R000.322.101.00.00 0.00 $2,075.65 PLAN CHECK FEE R000.345.832.00.00 0.00 $518.91 TECHNOLOGY FEE $103.78 TECHNOLOGY FEE TOTAL FEES PAID BY RECEIPT:R9930 R000.322.900.04.00 0.00 $103.78 $2,698.34 Date Paid: Tuesday, November 29, 2016 Paid By: SEQUOYAH LLC Pay Method: CHECK 551731 Printed: Tuesday, November 29, 2016 9:37 AM 1 of 1J SY5TEM 5 INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Project.6—A 6 P" - Type of Inspection. Address: � `` Date Called: Special Instructions: Date Wanted: ` a.m. .m. Requester: Phone No: Oki Approved per applicable codes. Corrections required prior to approval. Iinspector: , /Ir (,)(- A jlfK IDate: 02"1 t-1'tI REINSPECTION FEE REQUIRED. Prior to next inspection. tee must be paid at 6300 Sobthcenter Blvd., Suite 100. Call to schedule reinspection. INSPECTION RECORD ( Retain a copy with permit INSPECTION NO. PERMIT I. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Project: ��r ji4 T e of Inspection: i&1� Address:2 0 Da Called: Special Instructions: Date Wanted: Ca.mo Requester: Phone No: oApproved per applicable codes. LJ Corrections required prior to approval. I paid at 6300 Southcenter Blvd.. Suite 100. Catt to schedule reinspection. PLANT 2 AIRPLANE STORAGE (W4368468) ELECTRICAL LOAD CALCULATION 11/22/16 Page 1 NOTES ON SPECIAL LOADS rIL 480V, 200A Receptacles: There are a total of (4) 480V, 200A receptacles on this project. Their purpose is to feed a 400 Hz power cart. The input rating is 480V, 3 phase, 146 kVA, 126 kW, 176A. The cart has dual outputs. Each output is rated 200/115V, 400 Hz, 3 phase, 90 kVA, 72 kW, 260A. The total output is rated 150 kVA, 120 kW, 433 A. There will be a single power cart, which will move around to the different positions, and provide limited power for exercising airplane control surfaces. The actual load is expected to be much less than 480V, 176A, however this value is used in the load calculations. There are two receptacles for each power island, which are non-simultaneous loads; therfore, the diversity factor for 200A receptacles at a power island panel is 50%. There are four total 480V, 200A receptacles, so the diversity factor at panel MD1 is 25%. 480V, 60A Receptacles: There are a total of (8) 480V, 60A receptacles on this project. Their purpose is to feed a heater cart, which maintains ambient temperature inside of one airplane during cold weather. The rating of a heater cart is 480V, 38A. This has the potential to be a continuous load, and so it is calculated at 125%, or 47.5 A. All (8) heater carts can be in simultaneous operation, there is no load diversity. 480V, 30A Receptacles: There are two per power island, four total on the project. There is no dedicated equipment for them. They may be used for maintenance purposes, to be determined. An allowance of 10A each has been provided. Lighting Load: Each pole has (6) fixtures, each fixture drawing 1 AA at 240V Panel AP1-1 serves 3 poles, for a total of 18 fixtures Panel AP2-1 serves 2 poles, for a total of 12 fixtures LOAD CALCULATION See one -line diagram 02-YD-MD1 E4 for the panels served by main panel MD1 Panel AP1-1 (120/240V, single phase mini power zone, 25 kVA) Light poles: 18 fixtures x 1 AA x 125% 31.5 7.56 kVA 120V receptacles: (4) duplex @ 0.18 kVA 0.72 kVA (4) single @ 0.18 kVA 0.72 kVA Total for AP1-1 9 kVA Panel AP2-1 (120/240V, single phase mini power zone, 25 kVA) Light poles: 18 fixtures x 1.4A x 125% 21 5.04 kVA 120V receptacles: (4) duplex @ 0.18 kVA 0.72 kVA (4) single @ 0.18 kVA 0.72 kVA Total for AP2-1 6.48 kVA ELJ(P- 1083 REVIEWED FUH COMPLIANCE WITH NFPA 70 g NEC DEC -0 6 2016 City 0f Tukwila BUILDING DIVISION /6 RECEIVED CITY OF TUKWILA NOV 2 91016 PERMIT CENTER PLANT 2 AIRPLANE STORAGE (W4368468) ELECTRICAL LOAD CALCULATION 11/22/16 Page 2 Panel A (Relocated Crew Shelter) (120/240V, single phase 100A panel, fed from 25 kVA transformer) Total for Panel A (assumed to be 100A) 24 kVA Panel L1 (208Y/120V, 3 phase, 400A MLO, served from 75 kVA transformer via 200A fused disconnect) Heater in medium voltage switch 20A 208V 4.16 kVA Total for L1 4.16 kVA Panel H3 (480V, 3 phase, 400A) 49! �Y `F� ?.5554 � �/Z� 1 & �O'�p�ECIStER� C� " �Sj41VAi�O Phase A Phase B Phase C Amps Amps Amps Panel A 50 50 Panel L1 8.7 8.7 Total for Panel H3 50 58.7 8.7 Panel AP1 (480V, 3 phase, 800A MLO served from 600A circuit breaker) Phase A Phase B Phase C Amps Amps Amps 200A receptacles 176 176 176 60A receptacles 190 190 190 30A receptacles 20 20 20 Panel AP1-1 18.75 18.75 Total for Panel AP1 404.8 404.8 386.0 Panel AP2 (480V, 3 phase, 800A MLO served from 600A circuit breaker) Phase A Phase B Phase C Amps Amps Amps 200A receptacles 176 176 176 60A receptacles 190 190 190 30A receptacles 20 20 20 Panel AP2-1 13.5 13.5 Total for Panel AP2 399.5 399.5 386.0 49! �Y `F� ?.5554 � �/Z� 1 & �O'�p�ECIStER� C� " �Sj41VAi�O PLANT 2 AIRPLANE STORAGE (W4368468) ELECTRICAL LOAD CALCULATION 11/22/16 Page 3 Panel MD1 (480V, 3 phase 1600A MLO, sum of breakers 600+600+400 =1600A) * Correction is for non -simultaneous use of 480V, 200A receptacles (see "NOTES ON SPECIAL LOADS") Rating of feeder to Panel MD1 (4 sets of 600 kcmil) 1680 Amps (complies with NEC 240.21(C)(2)) 1500 kVA Pad Mount Transformer Primary Load 22.8 Amps 13.8 kV Transformer Primary Switch Fuse Size 100 Amps Feeder Ampacity Between Switch & Transformer (250 kcmil) 325 Amps Feeder Ampacity between Vault 21 & Switch (500 kcmil) 370 Amps ,i Phase A Phase B Phase C Amps Amps Amps Panel AP1 404.8 404.8 386.0 Panel AP2 399.5 399.5 386.0 Panel H3 50.0 58.7 8.7 Correction -176.0 -176.0 -176.0 Total for Panel MD1 678.3 687.0 604.7 545.7 kVA * Correction is for non -simultaneous use of 480V, 200A receptacles (see "NOTES ON SPECIAL LOADS") Rating of feeder to Panel MD1 (4 sets of 600 kcmil) 1680 Amps (complies with NEC 240.21(C)(2)) 1500 kVA Pad Mount Transformer Primary Load 22.8 Amps 13.8 kV Transformer Primary Switch Fuse Size 100 Amps Feeder Ampacity Between Switch & Transformer (250 kcmil) 325 Amps Feeder Ampacity between Vault 21 & Switch (500 kcmil) 370 Amps ,i PERI11T COORD COPS:. PLAN REVIEW/ROUTING SLIP PERMIT NUMBER: EL16-1083 DATE: 11/29/16 PROJECT NAME: BOEING - SE PARKING LOT SITE ADDRESS: 8123 E MARGINAL WAY S X Original Plan Submittal Revision # before Permit Issued Response to Correction Letter #, Revision # after Permit Issued DEPARTMENTS: A AWL Q�l Building Division a Fire Prevention ❑ Planning Division ❑ Public Works ❑ Structural ❑ Permit Coordinator PRELIMINARY REVIEW: DATE: 12/01/16 Not Applicable ❑ Structural Review Required ❑ (no approval/review required) REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: DUE DATE: 12/29/16 Approved ❑ Approved with Conditions Corrections Required ❑ Denied ❑ (corrections entered in Reviews) (ie: Zoning Issues) Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: 12/18/2013 SEQUOYAH ELECTRIC LLC Home Espanol Contact Safety & Health Washington State Department of Labor & Industries SEQUOYAH ELECTRIC LLC Owner or tradesperson Principals Nichols, David E, PARTNER/MEMBER GHASSEMI, MAHMOOD, PARTNER/MEMBER Angeline, Scott R, PARTNER/MEMBER Jeffrey, Peter Casino, PARTNER/MEMBER Trocano, Rick, PARTNER/MEMBER Nagel, Cheryl L, PARTNER/MEMBER Nichols, Christopher R, PARTNER/MEMBER Doing business as SEQUOYAH ELECTRIC LLC Page 1 of 2 (Search L&I I A-7, Index Help My 1,&-j Claims & Insurance Workplace Rights Trades & Licensing 15135 NE 92ND ST REDMOND, WA 98052 425-814-6000 KING County WA UBI No. Business type 602 252 591 Limited Liability Company Governing persons DAVID E NICHOLS MAHMOOD GHASSEMI; License Verify the contractor's active registration / license / certification (depending on trade) and any past violations. Electrical Contractor Active. Meets current requirements. License specialties GENERAL License no. SEQUOEL977S9 Effective — expiration 01/2912003— 01/30/2017 Designated administrator. NICHOLS, DAVID E License type Master Electrician Bond HARTFORD CAS INS CO Bond account no. 62BSBAB5641 Received by L&I 01/29/2003 Active. Meets current requirements. License no. NICHODE97406 $4,000.00 Effective date 01/29/2003 Expiration date Until Canceled Help us improve https://secure.lni.wa.gov/verify/Detail.aspx?UBI=602252591&LIC=SEQUOEL977S9&SAW= 12/8/2016 = OEING COMMERCIAL IRPLANES PLANT 2 •SOUTH AIRPLANE STORAGE PROJECT #W4368468 VICINITY MAP CODE SUMMARY DRAWING INDEX manges snail to the Of Mtork w thou,, Rrcr approval o f Tukwila Building Division, P�+CTL: GVIJ:L J %•riff require a new plan submittst and may include additional plan review tees. PROJECT SUMMARY DESCRIPTION OF WORK: PROVIDE STORAGE PARKING FOR (8) 737 AIRPLANES. POWER TO BE PROVIDED FROM (2) POWER ISLANDS. SECURITY LIGHTING TO BE PROVIDED FROM (5) LIGHT POLES. GROUNDING LOCATIONS PROVIDED FOR AIRCRAFT STATIC GROUND, CONTRACTOR: WASHINGTON PATRIOT (GENERAL) SEQUOYAH ELECTRIC (ELECTRICAL) ELECTRICAL ENGINEER: WALTER R. KNOX, PE BOEING FACILITIES ENGINEERING 206-662-6444 SITE ADDRESS: 7775 EAST MARGINAL WAY SOUTH TUKWILA, WA OWNER: THE BOEING COMPANY SHARED SERVICES GROUP P.O. BOX 3707, M/C: 2R-78 SEATTLE, WA. 98124-2207 OWNER CONTACT: JOHN MURDOCH 253-740-0214 KING COUNTY PARCEL NO. 3324049002 0001600020 LE COPY Permit No.. �1'1 � Plan raTla ' nonroval is subject to errors and o�issiors. Approval of construction documents does riot au ho i-3 the violation of any adopted cods or ordinance. 13=71 ;t of approved Field Copy and conditions is acknowledgei: By Date: City of TukWil$ BUILDING DIVISION REVIEWED FU-. COMPLIANCE WITS -I NEPA 70 - NEC DEC 0 6 2016 �'> wf� City of-TukWila BUILDING DIVISION RECEIVED CITY OF TUKWI A NOV 2 9 2016 PERMIT CENT9R O,` vR R --Q�0 ACCEPTABILITY ulzAwN uarE SUBTITLE COVER SHEET CURRENT REVISION SYMBOL _ DATE 11/18/16 SYM REVISION BY APPROVED DATE SYM REVISION BY APPROVED DATE O O! O O OD THIS DESIGN AND/OR CHECKED �. SPECIFlCATION IS APPROVED SHEET N Z o APPROVED BY DEPT. DATE ENGINEER TITLE CHECKED PLANT 2 YARD EO APPROVED JOB NO. COMP NO. oo W4368468 �\o°o f APPROVED DWG N0. 0 L 0 ij (,� ELECTRICAL MASTER PLANT 2 02—YD—EO SHEET NO. SHEET NAME REVISION 02—YD—EO COVER SHEET ORIG 02—YD—V21 E4 ONE—LINE DIAGRAM — VAULT 21 G 02—YD—MD1E4 ONE—LINE DIAGRAM — PANEL MD1 ORIG SE �A, N1 IT 02—YD—E32 LIGHTING C Rcui(tJ FOR: 02—YD—E33 LIGHTING C ��/� 02—YD—E82 120/208V & GROUNDING A 2 Mechanical 02—YD—E83 120/208V & GROUNDING A ❑ fE ectr;cat 02—YD—E133 48OV, MED. VOLTAGE D rnbing 02—YD—E599 POWER ISLAND DETAIL ORIG �8'PP tjd'Gas Piping 03—YD—S567 LIGHT POLE SECTIONS AND DETAILS C City of Tuhwilla 03—YD—S568 LIGHT POLE SECTIONS AND DETAILS B WILDiI IG DIVISION manges snail to the Of Mtork w thou,, Rrcr approval o f Tukwila Building Division, P�+CTL: GVIJ:L J %•riff require a new plan submittst and may include additional plan review tees. PROJECT SUMMARY DESCRIPTION OF WORK: PROVIDE STORAGE PARKING FOR (8) 737 AIRPLANES. POWER TO BE PROVIDED FROM (2) POWER ISLANDS. SECURITY LIGHTING TO BE PROVIDED FROM (5) LIGHT POLES. GROUNDING LOCATIONS PROVIDED FOR AIRCRAFT STATIC GROUND, CONTRACTOR: WASHINGTON PATRIOT (GENERAL) SEQUOYAH ELECTRIC (ELECTRICAL) ELECTRICAL ENGINEER: WALTER R. KNOX, PE BOEING FACILITIES ENGINEERING 206-662-6444 SITE ADDRESS: 7775 EAST MARGINAL WAY SOUTH TUKWILA, WA OWNER: THE BOEING COMPANY SHARED SERVICES GROUP P.O. BOX 3707, M/C: 2R-78 SEATTLE, WA. 98124-2207 OWNER CONTACT: JOHN MURDOCH 253-740-0214 KING COUNTY PARCEL NO. 3324049002 0001600020 LE COPY Permit No.. �1'1 � Plan raTla ' nonroval is subject to errors and o�issiors. Approval of construction documents does riot au ho i-3 the violation of any adopted cods or ordinance. 13=71 ;t of approved Field Copy and conditions is acknowledgei: By Date: City of TukWil$ BUILDING DIVISION REVIEWED FU-. COMPLIANCE WITS -I NEPA 70 - NEC DEC 0 6 2016 �'> wf� City of-TukWila BUILDING DIVISION RECEIVED CITY OF TUKWI A NOV 2 9 2016 PERMIT CENT9R O,` vR R --Q�0 ACCEPTABILITY ulzAwN uarE SUBTITLE COVER SHEET CURRENT REVISION SYMBOL _ DATE 11/18/16 SYM REVISION BY APPROVED DATE SYM REVISION BY APPROVED DATE O O! O O OD THIS DESIGN AND/OR CHECKED �. SPECIFlCATION IS APPROVED SHEET N Z o APPROVED BY DEPT. DATE ENGINEER TITLE CHECKED PLANT 2 YARD EO APPROVED JOB NO. COMP NO. oo W4368468 �\o°o f APPROVED DWG N0. 0 L 0 ij (,� ELECTRICAL MASTER PLANT 2 02—YD—EO F_ 26KV INCOMING LINE FROM SEATTLE CITY LIGHT S&C ELECTRONIC FUSE 1 CAT. #7010-C40S4T3D8 3'x`2 �� 26.4KV-13.8KV 1 7.5 MVA Z=6.41% 3 2 Z GROUNDING RESISTOR 8000V, 200A, 40 OHM, 10 SEC, 760 DEGREE RISE CO -9 51G TAP: 1 200:5 TD: 3 INST: 39 — i — i 0.5E, 15KV 3AA, 250V r---------- (3) I I METERING PT'S SEATTLE CITY LIGHT 14400-120V ( METERING EQUIPMENT I I I I METERING ----------I (3) I I I I I .2 KV I MCOV r—j I I i i 0.5E, 15KV CPT I 13800-120/240V I (2) PT'S n 15 KVA 14400-120V A I I I ryF I 600:5 TS PM AS AM 3A, 250V MR (3) i 0-600A -M STATION 52 86 POWER 12-M 20/240 u i 100A 600:5 50 MR (3) 51 (3) CO -9 TAP: 3 TD: 8 INST: 39 vsvM 0-15KV SCALE 0-125V COIL AC PANELBOARD BREAKER BREIKER BREAKER BREAKER DC PANELBOARD 52-7 52-5 52-3 52-1 PREPARED SPACE - - - BREAKER INCOMING LINE BOEING 52-M STORAGE MAIN BREAKER SEATTLE CITY LIGHT COMPARTMENT PT'S & CPT METERING COMPARTMENT BATTERIES BREAKER BRE/.KER BREAKER BREAKER & 52-8 52-6 52-4 52-2 BATTERY CHARGER VAULT 20 - - - (T1E) (FUTURE) FRONT VIEW FROM AISLE MAIN BUS - 13.8KV, 1200A, 3PH, 3W LEGEND 5 G5 51G @ PROTECTIVE RELAY, ANSI DEVICE NUMBER SHOWN (3) 600:5 MULTI-RA110 CURRENT TRANSFORMER, RATIO AS SHOWN, MR 50:5— ZERO SEQUENCE CURRENT TRASFORMER, RATIO AS SHOWN As vs FTS]AMMETER SWITCH, VOLTMETER SWITCH, TEST SWITCH PM POWER MONITOR (SQ. D. POWER LOGIC) AM O AMMETER, VOLTMETER, SCALE AS SHOWN 0-600A 0 LOAD CABLE TERMINATION POINT G SEE SHEET E1 FOR ADDITIONAL SYMBOLS DESCRIPTION. GENERAL NOTES REFERENCE DRAWINGS CONSTRUCTION NOTES CONTRACTOR IS TO HAVE EATON ENGINEERING SERVICES VERIFY AND EVALUATE RELAY SETTINGS FOR THIS CIRCUIT BREAKER, AS PART OF THE SHORT CIRCUIT/COORDINATION/ARC FLASH STUDY, AND J IMPLEMENT ANY CHANGES, IF REQUIRED. J-0 V c0-11 CO -9 c0-11 CO -11 CO -11 CO -11 CO -11 TAP: 2 TAP: 2 TAP: 2 TAP: 2 TAP: 2 TAP: 2 TAP: 2 TD: 2 TD: 4 TD: 6 TD: 2 TD: 2 TD: 2 i TD: 2 INST: 15 INST: 30 INST: 144 INST: 15 INST: 15 INST: 15 i INST: 15 50 50 50 50 50 50 __a _ 50_} i __a _ 50 } 600:5 600:5 600:5 600:5 600:5 600:5 600:5 , , 600:5 MR MR MR MR MR MR MR (3) 51 MR (3) 51 (3) 51 (3) 51 (3) 51 (3) 51 (3) . �1,. i '-T (3) I (3) 1 (3) 1 (3) 1 (3) 1(3) 1 (3) i (3)(3) . T I I I I I I ,. I i FUTURE I--) 1200.0 52 52-1 52-2 52-3 �_— 52-4 �_— 52-5 -- 52-6 f-- 52-7 �', f__ , _t - -� -� J -# KIRK -KEY uK L 1200.0 I 1200.0 I 1200.0 I 1200.0 1 1200.0 I 1200.0 I 1200.0 W� I I INTERLOCK I W TS PM AS AM 600:5 TS PM AS AM r- r--, r--, 600:5 TS PM AS AM 600:5 600:5 TS PM AS AM 600:5 TS PM AS AM 600:5 TS PM AS AM 600: 5 ---- (- i TS r PM r AS ,- AM , I 600: 5 -- j- ; TS r PM -1 AS F-4 AM ; MR MRI 0-600.0 MR I 0-600A MR I 0-600A MR I 0-600A MR I 0-600.0 MR I L_ -J L --J 600A I MR I L_ -J L__J 0-600A I I I I I I 0- 1 1 0-600A 7 I I I i I I I I I 50:5 50 51 50:5 50 5 50:5 50 5 50:5 50 5 50:5 50 5 50:5 50 51 50:5 ' 50 G G G G 50:551,; CO -11 Co -11 - -' -' ----' co -11 1 CO -11 ( co -11 ( co -11 1 CO -11 TAP: 1.5 TAP: 2 ( TAP: 1 f TAP: 1.5 TAP: 1.5 TAP: 1.5 1I TAP: 1.5 j TD: 2 1 TD: 3 1 TD: 1 I TD: 2 I TD: 2 1 TD: 2 1 I 1 TD: 2 INST: 39 INST: 39 INST: 5 INST: 39 INST: 39 INST: 39 FEEDER 21-8 INST: 39 FEEDER 21-1 FEEDER 21-2 FEEDER 21-3 FEEDER 21-4 FEEDER 21-5 FEEDER 21-6 PREPARED FEEDER 21-7 SPARE SPARE 3#4/0, #1 GND 3#500MCM 3#500MCM, #4/0 GND SPARE SPACE ONLY (2) SETS 3 #500kcmil, 1 #4/OGND (FORMERLY FED VAULT 5) TO VAULT 52, SWITCHES SWITCH V113 FEEDING 1500 KVA PAD MOUNT TO VAULT 50/SUB 50A VAULT 20 (TIE) SW1-1 & SW2-1 TRANSFOMER FOR 1600A PANEL MD1 & VAULT 51/SUB 51A (FUTURE) .� � RECEIVED ONE -LINE DIAGRAM - VAULT 21DEC SCALE: NONE V21 E4 ��� � 6 ���6 NOV 2 9 2016 City ofTUE FIE PERMIT CENTER I3U11-DMCURe of- BUILO O RAW A SUBTITLE SYMBOL DATE SYM REVISION BY APPROVED DATE SYM REVISION BY APPROVED DATE p� R R, oo ACCEPTABILITY K. READ 10/8/98 ONE -LINE DIAGRAM -VAULT 21 o �............. oW4368468 11/18/16 A REFEED VAULT 5 AND VAULT 9 981004 KR CS 10/13/98 F PLANT 2 ELECTRICAL POWER UPGRADE 15644/20111 CEI PWJ 11.11.13 Op ;''pFWASy� 2 o THIS DESIGN AND/OR C C SHEET p Q,: `F, ti • O O SPECIRCATION IS APPROVED ENGINEER B ADD VAULT 50 FEEDER FOR BUILDING 2-81 972197 KR RECORD DRAWING 15644/20111 CEI 07.24.15 ® R _ APPROVED BY DEPT. DATE K. READ 10/8/98 1iTLE PLANT 2 ELECTRICAL POWER UPGRADE �� C RECORD DRAWING J#982190-00 HGI/SDB 03.1.01 G AIRPLANE STORAGE W4368468 KNOX 11/18/16 ,��Zj° CH KE 1 E4 D AC DEMO 2-62 J#120253-00 KNOX CAS 06.12.02 O p C. STEWART 10 13 98 VAULT 2 1 JOB NO. COMP NO. 00 P „ED 716945-00 STUDY DATA TEB 02.15.10 0o�ONAL Eo0� AP RovED ELECTRICAL MASTER YARD PLANT 2 WA DWG NO. 02 -YD -V21 E4 E AS BUILT ARC FLASH A O O L SYM I REVISION ORIG I AIRPLANE STORAGE BY I APPROVED I DATE I SYM W43684681 KNOX 1 111/18/161 REVISION TO VAULT 21, FEEDER 21-4 (SEE DWG: 02 -YD V21 E4) 0 0 MANHOLE E MANHOLE F (LOAD BREAK CONNECTORS) 01 120/208V 15KV, 600A "A" 0 (LEFT BUS IN PANEL) BLACK HV SW Vi 13 "B" 0 CENTER BUS IN PANEL) 100A Q "C" 0RIGHT BUS IN PANEL) BLUE 13.8KV -+,. 1500 KVA 3/0 G.E.C. 480V277V EQUIPMENT GROUND ??6.519 Z O ISOLATED GROUND LOCATED OUTDOORS N. OF BLDG. 2-80 SEE 02 -YD -E133 LEGEND GENERAL NOTES 1. CONDUIT TO BE 1/2" EMT UNLESS OTHERWISE NOTED. 2. ALL WIRE TO BE #12 THHN UNLESS OTHERWISE NOTED. 3. THE FOLLOWING COLOR CODING OF CONDUCTORS SHALL BE OBSERVED ON ALL CIRCUITS 600 -VOLTS OR LESS. LARGE SIZE CONDUCTORS SHALL BE IDENTIFIED WITH COLORED TAPE WHERE EVER VISIBLE. 5. INSTALL NEW OR REVISED PANEL SCHEDULES UPON COMPLETION OF JOB. 120/208V 277/480V "A" 0 (LEFT BUS IN PANEL) BLACK BROWN "B" 0 CENTER BUS IN PANEL) RED ORANGE "C" 0RIGHT BUS IN PANEL) BLUE YELLOW NEUTRAL WHITE GRAY EQUIPMENT GROUND GREEN SIZE ISOLATED GROUND GRN/YEL GRN/YEL 4. DYMO LABEL ALL RECEPTACLES, JUNCTION BOXES, SWITCHES,ETC., WITH CIRCUIT IDENTIFICATION. 4" 5. INSTALL NEW OR REVISED PANEL SCHEDULES UPON COMPLETION OF JOB. -25KVA 480-120/240V N G.E.C. - #4' IN 1/2" PNL. A SCH. 80 100A PVC 120/240V TO 4/0 SYS. 1 PH 3W GND. 1,a CREW SHELTER =p 75KVA 480-208Y/120V 'th X }j 200A, FUSED (PART OF MPZ) I (PART OF MPZ) ULI 25KVA 25KVA — 480-120/240V _ 480-120/240V CONSTRUCTION NOTES AP2-1 1600A MDLO 125A G.E.C. - #4 120/240V IN 1/2" 11PH, IPH, 3W IN 1/2" SCH. 80 SCH. 80 (PARTOF MPZ, ) PVC (PARTOF MPZ) PVC TO 4/0 SYS. TO 4/0 SYS. 480Y/277V GND. SIZE PHASE NEUTRAL GND IG 3 PH, 4W 1 4" 3-500KCMIL � REMOVE (1) 600A AND (2) 200A CIRCUIT BREAKERS AND 2� 2 4" 3-250KCMIL PROVIDE BLANK COVERS. (LIMIT SUM OF BREAKERS TO O 30 1600A 4 4" O5 1600A). 4O 5 0 2 2" � REPLACE EXISTING FEEDERS (2 SETS OF 4 - 500 KCMIL) WITH 2 SETS OF 600 KCMIL (NECESSARY TO COMPLY WITH #1 O 600A 2 3" 3-350KCMIL #1 60 70A 3 D 1" 2#4 NEC 240.21(C)(1)b). 7 110A 1 PROVIDE POWER TO POWER ISLANDS. SEE 02 -YD -E599. 2#1 PNL. H3 #6 PNL. AP1 PNL. AP2 ® PROVIDE TRANSFORMER. PROVIDE POWER TO EXISTING 400A 800A MLO 600A MLO PANEL A IN CREW SHELTER, 480V 480V 480V 3 PH, 3W 3 PH, 3W 3 PH, 3W 5. HIRE THE SERVICES OF EATON ENGINEERING SERVICES, TO DO A SHORT CIRCUIT AND ARC FLASH STUDY, BY ADDING O6 6 60 ON TO THE EXISTING BOEING SKM MODEL. PROVIDE NEW ARC FLASH LABELS FOR THE MEDIUM VOLTAGE SWITCH V113, o AND FOR ALL PANELBOARDS SHOWN ON THIS DRAWING. A PREVIOUS EATON STUDY TQSISE0009436.1 WAS DONE WHEN d PANELS MD1, H3 AND L1 WERE ORIGINALLY INSTALLED. PROVIDE THE STUDY IN ELECTRONIC FORMAT TO BOEING. -25KVA 480-120/240V N G.E.C. - #4' IN 1/2" PNL. A SCH. 80 100A PVC 120/240V TO 4/0 SYS. 1 PH 3W GND. 1,a CREW SHELTER =p 75KVA 480-208Y/120V 'th X }j 200A, FUSED (PART OF MPZ) I (PART OF MPZ) ULI 25KVA 25KVA — 480-120/240V _ 480-120/240V AP1-1 AP2-1 125A G.E.C. - #4 120/240V 125A G.E.C. - #4 120/240V IN 1/2" 11PH, IPH, 3W IN 1/2" SCH. 80 SCH. 80 (PARTOF MPZ, ) PVC (PARTOF MPZ) PVC TO 4/0 SYS. TO 4/0 SYS. GND. GND. ONE LINE DIAGRAM- PANEL MD1 SCALE: NONE BY I APPROVED I DATE REVIEWED (;OMPLIANGE WiTh NFPA70 - FIFO DEC 0 6 7016 City of Tukvifla BUILDING DIVISI01"O: DRAWN DATE SUBTru ACCEPTABILITY RFMORALES 10.07.16 THIS DESIGN AND/OR CHECKED SPECIFICATION IS APPROVED ENGINEER ME APPROVED BY I DEPT. I DATE ELECTICAL RECEIVED CITY OF TUKWILA NOV 2 9 2016 PERMIT CENTER. 1N'7777. ,10 ONE LINE DIAGRAM - PANEL MD1 02 -YD COL. X PLANT2, WA R I GI DATE 11/18/16 02 -YD -MDI E4 CONDUCTORS PER CONDUIT TYPE RATINGCONDUIT QTY SIZE PHASE NEUTRAL GND IG 10 1 4" 3-500KCMIL 2� 2 4" 3-250KCMIL 30 1600A 4 4" 4-600KCMIL 4O 400A 2 2" 3#4/0 #1 O 600A 2 3" 3-350KCMIL #1 60 70A 1 1" 2#4 #8 7 110A 1 1 1/4" 2#1 1 #1 #6 1N'7777. ,10 ONE LINE DIAGRAM - PANEL MD1 02 -YD COL. X PLANT2, WA R I GI DATE 11/18/16 02 -YD -MDI E4 henr('u I Inif7 - rMITIM IATlr)M CFF CNFFT 1791 SYM REVISION — 2-4X DEMO A SITE REDEVELOPMENT B SITE REDEVELOPMENT — DCN #10 — SITE REDEVELOPMENT — RECORD DRAWING AS—BUILT INCORP REVISION F MATCH LINE - CONTINUATION SEE SHEET E41 BY I APPROVED I DATE W43684681 KNOX 1 111/18/16 �< R. . F WAS'. lti �Fcisr��� I; REVIEWED SOH COMPLIANCE WITH' NFPA 70 d NEC DEC 0 6 2016 City of Tukwila I BUILDING DIVISIQ ACCEPTABILITY 1J.OMALLEY THIS DESIGN AND/OR SPECIFICATION IS APPROVED APPROVED BY I DEPT. I DATE 01.16.97 ELECTRICAL MASTER A 400W HI C TYP E32 I E504 LEGEND -° POLE MOUNTED - DOUBLE HEAD LUMINAIRE POLE MOUNTED - SINGLE HEAD LUMINAIRE BOLLARD UTILITY VAULT —AA1l 40 -\ LIGHTING FIXTURE IDENTIFIER LIGHT POLE MOUNTED TO 6.5'x6.5x3.5' CONCRETE BASE, FORKLIFT PORTABLE. WITH (6) 300W, 37 DEGREE FLOODLIGHTS, E-CONOLIGHT #E-HL9S30NSZ ON THE TOP RUNGS. TILT ALL FIXTURES DOWN 10 DEGREES FROM VERTICAL. ROTATED FIXTURES ARE AT 30 DEGREES ROTATION FROM STRAIGHT AHEAD. SEE POLE DETAIL A ON DRAWING E47 5567 03 -YD -S567 GENERAL NOTES 1. CONDUIT TO BE RIGID ALUMINUM UNLESS OTHERWISE NOTED. 2. UNLESS OTHERWISE NOTED, WIRE IS STRANDED COPPER, TYPE XHHW-2 INSULATION, MINIMUM SIZE #12 FOR POWER & #14 AWG FOR CONTROL. BY APPROVED DATE SYM SEE 586456-02 SAZAN/MN E10 04.03.09 C AIRPLANE STORAGE 586456-02 SAZAN/GBG E21 06.17.11 A 40C�W H E18 586456-02 SAZAN/GBG IDENTIFIED WITH COLORED TAPE WHEREVER VISIBLE: 208Y 120V 480Y 277V 03.02.12 E31 E30 586456-02 SAZAN/GBG E27 02.20.13 BROWN E42 E41 DP W 10/30/141 ORANGE 1 REVISION F MATCH LINE - CONTINUATION SEE SHEET E41 BY I APPROVED I DATE W43684681 KNOX 1 111/18/16 �< R. . F WAS'. lti �Fcisr��� I; REVIEWED SOH COMPLIANCE WITH' NFPA 70 d NEC DEC 0 6 2016 City of Tukwila I BUILDING DIVISIQ ACCEPTABILITY 1J.OMALLEY THIS DESIGN AND/OR SPECIFICATION IS APPROVED APPROVED BY I DEPT. I DATE 01.16.97 ELECTRICAL MASTER A 400W HI C TYP E32 I E504 LEGEND -° POLE MOUNTED - DOUBLE HEAD LUMINAIRE POLE MOUNTED - SINGLE HEAD LUMINAIRE BOLLARD UTILITY VAULT —AA1l 40 -\ LIGHTING FIXTURE IDENTIFIER LIGHT POLE MOUNTED TO 6.5'x6.5x3.5' CONCRETE BASE, FORKLIFT PORTABLE. WITH (6) 300W, 37 DEGREE FLOODLIGHTS, E-CONOLIGHT #E-HL9S30NSZ ON THE TOP RUNGS. TILT ALL FIXTURES DOWN 10 DEGREES FROM VERTICAL. ROTATED FIXTURES ARE AT 30 DEGREES ROTATION FROM STRAIGHT AHEAD. SEE POLE DETAIL A ON DRAWING E47 5567 03 -YD -S567 GENERAL NOTES 1. CONDUIT TO BE RIGID ALUMINUM UNLESS OTHERWISE NOTED. 2. UNLESS OTHERWISE NOTED, WIRE IS STRANDED COPPER, TYPE XHHW-2 INSULATION, MINIMUM SIZE #12 FOR POWER & #14 AWG FOR CONTROL. 0_ �0000000 C A 40QW H S LIGHTING AIRPLANE STORAGE PLANT 2 YARD 4. PERMANENTLY LABEL ALL RECEPTACLES, JUNCTION BOXES, SWITCHES, ETC., WITH PANEL AND CIRCUIT IDENTIFICATION. 5. INSTALL NEW OR REVISED PANEL SCHEDULES UPON COMPLETION OF JOB. REFERENCE DRAWINGS SEE SHT 2YD-E503 FOR LTG FIXTURE SCHEDULE. 3. THE FOLLOWING COLOR CODING OF CONDUCTORS SEE SHT 2YD-505 E10 SHALL BE OBSERVED ON ALL CIRCUITS 600 -VOLTS I E24 E23 E22 E21 OR LESS. LARGE SIZE CONDUCTORS SHALL BE A 40C�W H E18 E35 E34 IDENTIFIED WITH COLORED TAPE WHEREVER VISIBLE: 208Y 120V 480Y 277V E32 I E31 E30 E29 E28 E27 "A" 0 (LEFT BUS IN PNL) BLACK BROWN E42 E41 E40 W "B" 0 (CENTER BUS IN PNL) RED ORANGE E36 "C" 0 (RIGHT BUS IN PNL) BLUE YELLOW NEUTRAL WHITE GREY ,. EQUIPMENT GROUND GREEN GREEN 0_ �0000000 C A 40QW H S LIGHTING AIRPLANE STORAGE PLANT 2 YARD 4. PERMANENTLY LABEL ALL RECEPTACLES, JUNCTION BOXES, SWITCHES, ETC., WITH PANEL AND CIRCUIT IDENTIFICATION. 5. INSTALL NEW OR REVISED PANEL SCHEDULES UPON COMPLETION OF JOB. REFERENCE DRAWINGS CONSTRUCTION NOTES PROVIDE CONCRETE BLOCK WITH STEEL POLE. INSTALL (6) LED 30OW FLOOD LIGHTS ON THE TOP RUNGS OF EACH POLE AS INDICATED. INSTALL CONDUIT AND WIRE BETWEEN EACH POLE AND THE ASSOCIATED LIGHTING CONTACTOR, FED FROM THE MINI POWER ZONE 20 AMP, 2 POLE CIRCUIT INDICATED. NO EXPOSED GALVANIZED CONDUIT IS ALLOWED, DUE TO RESTRICTIONS ON ZINC IN STORM WATER. RECEIVED CITY OF TUKWILA NOV 2 9 2010 20 10 0 2oPERMIT46ENTER60 SCALE IN FEET SEE SHT 2YD-E503 FOR LTG FIXTURE SCHEDULE. E14 SEE SHT 2YD-505 CONSTRUCTION NOTES PROVIDE CONCRETE BLOCK WITH STEEL POLE. INSTALL (6) LED 30OW FLOOD LIGHTS ON THE TOP RUNGS OF EACH POLE AS INDICATED. INSTALL CONDUIT AND WIRE BETWEEN EACH POLE AND THE ASSOCIATED LIGHTING CONTACTOR, FED FROM THE MINI POWER ZONE 20 AMP, 2 POLE CIRCUIT INDICATED. NO EXPOSED GALVANIZED CONDUIT IS ALLOWED, DUE TO RESTRICTIONS ON ZINC IN STORM WATER. RECEIVED CITY OF TUKWILA NOV 2 9 2010 20 10 0 2oPERMIT46ENTER60 SCALE IN FEET PLANT2, WA E32 586456-02 KEY PLAN N SCALE : NONE DL ^ DATE 11/18/16 2YD-E32 =E16. E15 E14 E13 E12 E11 E10 E26 E25 I E24 E23 E22 E21 E20 E19 E18 E35 E34 E33 E32 I E31 E30 E29 E28 E27 E44 E43 E42 E41 E40 E39 E38 E37 E36 PLANT2, WA E32 586456-02 KEY PLAN N SCALE : NONE DL ^ DATE 11/18/16 2YD-E32 v w n w _ U) L LJ w 07 z CD z I= z 0 U I w z U Q _3END POLE MOUNTED - DOUBLE HEAD LUMINAIRE POLE MOUNTED - SINGLE HEAD LUMINAIRE BOLLARD UTILITY VAULT C SS LIGHTING FIXTURE IDENTIFIER LIGHT POLE MOUNTED TO 6.5'x6.5'x3.5' CONCRETE BASE, FORKLIFT PORTABLE. WITH (6) 300W, 37 DEGREE FLOODLIGHTS, E-CONOLIGHT #E-HL9S30NSZ ON THE TOP RUNGS. TILT ALL FIXTURES DOWN 10 DEGREES FROM VERTICAL. ROTATED FIXTURES ARE AT 30 DEGREES ROTATION FROM STRAIGHT AHEAD. SEE POLE DETAIL A ON DRAWING 03 -YD -S567 E47 S567 ENERAL NOTES VDUIT TO BE RIGID ALUMINUM UNLESS OTHERWISE FED. .ESS OTHERWISE NOTED, WIRE IS STRANDED 'PER, TYPE XHHW-2 INSULATION, MINIMUM SIZE ? FOR POWER & #14 AWG FOR CONTROL. FOLLOWING COLOR CODING OF CONDUCTORS %LL BE OBSERVED ON ALL CIRCUITS 600 -VOLTS LESS. LARGE SIZE CONDUCTORS SHALL BE NTIFIED WITH COLORED TAPE WHEREVER VISIBLE: 208Y 120V 480Y 277V 0 (LEFT BUS IN PNL) BLACK BROWN 0 (CENTER BUS IN PNL) RED ORANGE 0 (RIGHT BUS IN PNL) BLUE YELLOW )TRAL WHITE GREY )IPMENT GROUND GREEN GREEN ,MANENTLY LABEL ALL RECEPTACLES, JUNCTION KES, SWITCHES, ETC., WITH PANEL AND CIRCUIT NTIFICATION. TALL NEW OR REVISED PANEL SCHEDULES UPON 1IPLETION OF JOB. EFERENCE DRAWINGS :E SHT 2YD-E503 FOR LTG FIXTURE SCHEDULE :E SHT 02-127-E507 ONSTRUCTION NOTES ZOVIDE CONCRETE BLOCK WITH STEEL POLE. STALL (6) LED 30OW FLOOD LIGHTS ON THE TOP 1NGS OF EACH POLE AS INDICATED. INSTALL )NDUIT AND WIRE BETWEEN EACH POLE AND THE ;SOCIATED LIGHTING CONTACTOR, FED FROM THE NI POWER ZONE 20 AMP, 2 POLE CIRCUIT DICATED. NO EXPOSED GALVANIZED CONDUIT IS .LOWED, DUE TO RESTRICTIONS ON ZINC IN STORM %TER. SCALE IN FEET MATCH LINE - CONTINUATION SEE SHEET E42 KEY PLAN ^' SCALE : NONE IV SYM REVISION BY APPROVED DATE SYM REVISION BY APPROVED DATE 00 00 DRAWN A SUBTITLE CURRENT REVISION SYMBOL DATE o R. R O ACCEPTABILITY MJM SP 10.13.97 C 11/18/16 o'' ... ••.��,°o THIS DESIGN AND/OR H C LIGHTING - DATABASE MAPPING UPDATE - DHA ASSOC. INC 10.13.97 - AS -BUILT INCORP DP 10/31/14 O �:' oFW`�Ni ' O DAH 10.13.97 SHEET p Q'`�, N�'••.O O SPECIFICATION IS APPROVED EITUREM, TITLE 2-4X DEMO 586456-02 SAZAN/MN 04.03.09 C AIRPLANE STORAGE W4368468 KNOX 11/18/16 0) �' APPROVED BY DEPT. DATE AIRPLANE STORAGE E33 A SITE REDEVELOPMENT 586456-02 SAZAN/GBG 06.17.11 0 KED i11 : 0 CPR PLANT 2 JOB N0. COMP N0. 8 SITE REDEVELOPMENT - DCN #10 586456-02 SAZAN/GBG 03.02.12 OO ISTER`�00 586456-02 O°` �ONAt '�o°O APPROVEDi , ELECTRICAL MASTER YARD PLANT2 WA DwG No. 2YD-E33 SITE REDEVELOPMENT RECORD DRAWING 586456-02 SAZAN/GBG 02.20.13 O O a E17 E15 E14 E13 E12 E11 E10 E26 E25 qE24 E23 E22 E21 E20 E19 E18 E35 E34 E32 E31 E30 E29 E28 E27 E44 E43 E41 E40 E39 E38 E37 E36 MATCH LINE - CONTINUATION SEE SHEET E42 KEY PLAN ^' SCALE : NONE IV SYM REVISION BY APPROVED DATE SYM REVISION BY APPROVED DATE 00 00 DRAWN A SUBTITLE CURRENT REVISION SYMBOL DATE o R. R O ACCEPTABILITY MJM SP 10.13.97 C 11/18/16 o'' ... ••.��,°o THIS DESIGN AND/OR H C LIGHTING - DATABASE MAPPING UPDATE - DHA ASSOC. INC 10.13.97 - AS -BUILT INCORP DP 10/31/14 O �:' oFW`�Ni ' O DAH 10.13.97 SHEET p Q'`�, N�'••.O O SPECIFICATION IS APPROVED EITUREM, TITLE 2-4X DEMO 586456-02 SAZAN/MN 04.03.09 C AIRPLANE STORAGE W4368468 KNOX 11/18/16 0) �' APPROVED BY DEPT. DATE AIRPLANE STORAGE E33 A SITE REDEVELOPMENT 586456-02 SAZAN/GBG 06.17.11 0 KED i11 : 0 CPR PLANT 2 JOB N0. COMP N0. 8 SITE REDEVELOPMENT - DCN #10 586456-02 SAZAN/GBG 03.02.12 OO ISTER`�00 586456-02 O°` �ONAt '�o°O APPROVEDi , ELECTRICAL MASTER YARD PLANT2 WA DwG No. 2YD-E33 SITE REDEVELOPMENT RECORD DRAWING 586456-02 SAZAN/GBG 02.20.13 O O a Z' O U ZI U QI :21 SYM I REVISION A I AIRPLANE STORAGE BY W43684681 KNOX w APPROVED DATE SYM 11/18/16 REVISION MATCH LINE - CONTINUATION SEE SHEET E73 _ O ICl MATCH LINE - CONTINUATION SEE SHEET E91 BY I APPROVED I DATE E Ulm � rot,4 -1 - Z.- 0 o0 R R v��o ACCEPTABILITY ��0 THIS DESIGN AND/OR ' k.4FW�y�'� .�pp SPECIFICATION IS APPROVED i APPROVED BY I DEPT. DATE �'��S�E��o% >v0h_ TNAL moo° R-1 ELECTRICAL MASTER 111LdLLJ W IV) �z O F- nnQ Z 10 U IU �Q I cr c Kln. 30'x3/4" COPPERCLAD SECTIONAL GROUND ROD, TOP AT 30" ABOVE GROUND, WITH (4) BRASS BLOCK/COPPER BRAID ATTACHMENTS (SEE D38201-13 FIGURE 9 FOR BRASS BLOCK/COPPER BRAID ASSEMBLY). TIE TO THE 4/0 SITE GROUNDING ELECTRODE CONDUCTOR. 0 GENERAL NOTES: a CONSTRUCTION NOTES: PROVIDE GROUND ROD WITH STATIC GROUNDING ATTACHMENTS (SEE LEGEND). TIE THIS GROUND ROD TO THE OTHER GROUND RODS (ON SHEET E83), USING SURFACE -MOUNTED STRANDED BARE CU 4/0 GROUNDING ELECTRODE CONDUCTOR IN 1" SCHED 80 PVC. REVIEWED FUR COMPLIANCE WITH I NFPA 70 m NEC I 120/208V & GROUNDING PLANT2 COL. X-X/X-X DEC 0 6 2016 City of-TukWila BUILDING DIVISION 41 RECEIVED CITY OF TUKWILA NOV 2 9 2016 PERMIT CENTER 20 10 0 20 40 6 SCALE IN FEET E67 E66 E65 I E64 E63 I E62 E61 I E6 E76 E75 E74 E73 E72 E71 E70 E69 E6 E85 E84 E83 E82 E81 E80 E79 E78 E7 E94 I E93 E92 E91 E90 E89 E88 E87 E8 KEY PLAN __0 SCALE : NONE CURRENT REVISION SYMBOL DATE W4368468 A 11/18/16 PLANT 2 2.YD-E82 u GROUND TRANSFORMER I In 4/0 WITH #4 BARE CU PROTECTED BY SCHED 80 PVC PANEL MD1 GROUND BUS Q I 0 I I PANEL A, 100A, 1120/240'/, 1 PHASE I I I I I I PANEL L1, 400A, 120/208V, 3 PHASE 4/0 STRANDED BARE CU GROUNDING ELECTRODE CONDUCTOR, PROTECTED BY 1" MATCH LINE - CONTINUATION SEE SHEET E74 D GROUND STAND TO 4/0 WITH 4/0 AWG BARE CU j ER ISLAND AP1 E DETAIL 1 E83 E599 LGROUND TRANSFORMER TO 4/0 WITH #4 AWG BARE CU IN SCHED 80 PVC �l PANEL AP1-1 V) I z O� Iz z c- o o ° I �ooaooa00000000a0000a� w z � I = I I U I— Q I o ICI IN o \ 0 0 0 0 � O D O D O C� 0 0 o MATCH LINE - CONTINUATION SEE SHEET E92 LEGEND 30'x3/4" COPPERCLAD SECTIONAL GROUND ROD, TOP AT 30" ABOVE GROUND, WITH (4) D BRASS BLOCK/COPPER BRAID ATTACHMENTS (SEE D38201-13 FIGURE 9 FOR BRASS GROUND STAND TO 4/0 BLOCK/COPPER BRAID ASSEMBLY). TIE TO THE WITH 4/0 AWG BARE CU 4/0 SITE GROUNDING ELECTRODE CONDUCTOR. POWER ISLAND AP2 m TRANSFORMER SEE DETAIL1 PANELBOARD, 120/208V, 3PH OR 120/240V E83 E599 GENERAL NOTES PANEL AP2-1 G C GROUND TRANSFORMER 1. NEW CONDUIT ABOVE GRADE TO BE RIGID ALUMINUM. TO 4/0 WITH #4 AWG 2. UNLESS OTHERWISE NOTED, WIRE IS STRANDED COPPER, TYPE BARE CU IN SCHED 80 XHHW-2 INSULATION, MINUMUM #12 AWG FOR POWER & #14 AWG FOR PVC Q CONTROL E60 3. THE FOLLOWING COLOR CODING OF CONDUCTORS SHALL BE E75 c� E73 m E71 m E69 I E85 "C" PHASE RIGHT BUS IN PANEL) BLUE YELLOW E83 NEUTRAL WHITE GRAY E81 EQUIPMENT GROUND GREEN GREEN E79 ISOLATED GROUND *GRN/YEL #GRN/YEL E77 s E93 C s E91 s D° w COLORED TAPE. - i H aw H o ® H a I = rq ria ria w Ld U) w w REFERENCE DRAWINGS V) 0i lz 2-YD-MD1E4 ONE -LINE DIAGRAM V) I z O� Iz z c- o o ° I �ooaooa00000000a0000a� w z � I = I I U I— Q I o ICI IN o \ 0 0 0 0 � O D O D O C� 0 0 o MATCH LINE - CONTINUATION SEE SHEET E92 LEGEND 30'x3/4" COPPERCLAD SECTIONAL GROUND ROD, TOP AT 30" ABOVE GROUND, WITH (4) D BRASS BLOCK/COPPER BRAID ATTACHMENTS (SEE D38201-13 FIGURE 9 FOR BRASS GROUND STAND TO 4/0 BLOCK/COPPER BRAID ASSEMBLY). TIE TO THE WITH 4/0 AWG BARE CU 4/0 SITE GROUNDING ELECTRODE CONDUCTOR. POWER ISLAND AP2 m TRANSFORMER SEE DETAIL1 PANELBOARD, 120/208V, 3PH OR 120/240V E83 E599 GENERAL NOTES PANEL AP2-1 G C GROUND TRANSFORMER 1. NEW CONDUIT ABOVE GRADE TO BE RIGID ALUMINUM. TO 4/0 WITH #4 AWG 2. UNLESS OTHERWISE NOTED, WIRE IS STRANDED COPPER, TYPE BARE CU IN SCHED 80 XHHW-2 INSULATION, MINUMUM #12 AWG FOR POWER & #14 AWG FOR PVC Q CONTROL E60 3. THE FOLLOWING COLOR CODING OF CONDUCTORS SHALL BE E75 OBSERVED ON ALL CIRCUITS 600 VOLTS OR LESS E73 2081120 480127 E71 "A" PHASE LEFT BUS IN PANEL) BLACK BROWN E69 "B"PHASE CENTER BUS IN PANEL) RED ORANGE E85 "C" PHASE RIGHT BUS IN PANEL) BLUE YELLOW E83 NEUTRAL WHITE GRAY E81 EQUIPMENT GROUND GREEN GREEN E79 ISOLATED GROUND *GRN/YEL #GRN/YEL E77 (*GREEN W/ YELLOW TRACER) E93 4. LARGE SIZE CONDUCTORS WHICH DO NOT HAVE COLORED JACKETS E91 SHALL BE IDENTIFIED WHEREVER VISIBLE BY APPROPRIATELY I E89 COLORED TAPE. I E87 5. ALL UNUSED CONDUIT AND WIRE TO BE REMOVED BACK TO SOURCE, INCLUDING PLUG -ON CIRCUIT BREAKERS ON BUSWAYS. 6. PERMANENTLY LABEL ALL RECEPTACLES, JUNCTION BOXES, SWITCHES, ETC., WITH PANEL AND CIRCUIT DESIGNATION. MN W w 7. POST REVISED PANEL SCHEDULES IN ELECTRICAL PANELS UPON w COMPLETION OF JOB. w U) w w REFERENCE DRAWINGS V) lz 2-YD-MD1E4 ONE -LINE DIAGRAM 0 DEC 0 6 2016 Citi Of -Tukwila. I BUILDING DIVISION _CONSTRUCTION NOTES PROVIDE GROUND ROD WITH STATIC GROUNDING ATTACHMENTS (SEE LEGEND): ADDITIONAL GROUND ROD SHOWN ON SHEET E82. TIE I GROUND RODS TOGETHER, AND TO GROUND Ll BUS OF PANEL MD1, USING SURFACE -MOUNTED STRANDED BARE CU 4/0 GROUNDING ELECTRODE CONDUCTOR IN 1" SCHED 80 PVC. t � GROUND METAL FRAME OF POWER ISLAND '- STAND, AND GROUND THE MINI POWER ZONE SECONDARY NEUTRAL, TO THE 4/0 GROUNDING ELECTRODE CONDUCTOR AS INDICATED. PROVIDE CONDUIT AND WIRE BETWEEN TRANSFORMER AND EXISTING CREW SHELTER 100A, 120/240V PANEL A. SEE ONE -LINE DIAGRAM 2-YD-MD1 E4 FOR SIZING. 20 10 0 20 40 60 SCALE IN FEET KEYPLAN N SCALE : NONE RECEIVED CITY OF TUKWILA NOV 2 9 2016 PERMIT CENTER SYM REVISION BY APPROVED DATE SYM REVISION BY APPROVED DATE pv� "Up DRAWN DATE SU8T17LE CURRENT REVISION SYMBOL DATE O R R. O ACCEPTABILITY � 120/208 & GROUNDING W4368468 A 11/18/16 A AIRPLANE STORAGE W4368468 KNOC 11/18/16 0°�oFWgsNi� ?�� Oo SP CHFlCATtoN NS APPROVED H SHEET ® 3 E83 APPROVED BY DEPT. DATE CHECKED PROV D PLANT 2 JOB N0. O F���(ic�,.•� � COMP N0. Op;'•••....... �, °� 000��pNAL Popo APPROVED ELECTRICAL MASTER COL. X-X/X-X PLANT 2, WA DWG N0. 2.YD-E83 E67 I E66 E65 E64 E63 E62 E61 E60 E76 E75 E74 E73 E72 E71 E70 E69 E68 E85 E84 E83 E82 E81 E80 E79 E78 E77 E94 E93 E92 E91 I E90 I E89 I E88 I E87 I E86 KEYPLAN N SCALE : NONE RECEIVED CITY OF TUKWILA NOV 2 9 2016 PERMIT CENTER SYM REVISION BY APPROVED DATE SYM REVISION BY APPROVED DATE pv� "Up DRAWN DATE SU8T17LE CURRENT REVISION SYMBOL DATE O R R. O ACCEPTABILITY � 120/208 & GROUNDING W4368468 A 11/18/16 A AIRPLANE STORAGE W4368468 KNOC 11/18/16 0°�oFWgsNi� ?�� Oo SP CHFlCATtoN NS APPROVED H SHEET ® 3 E83 APPROVED BY DEPT. DATE CHECKED PROV D PLANT 2 JOB N0. O F���(ic�,.•� � COMP N0. Op;'•••....... �, °� 000��pNAL Popo APPROVED ELECTRICAL MASTER COL. X-X/X-X PLANT 2, WA DWG N0. 2.YD-E83 e TO VAULT 21 VIA H -E & Fes! 4"C.3#500 KCMIL PC1-VAULT G13 504PL, 600A 15KV, 100A FUSED SW (VI13) VAULT H13 504PL, 600A 15KV } (SUMMIT 1500 KVA, 480/277V) 12 PNL. H3, 400A, 480/277V, � 3 PHASE / MATCH LINE - CONTINUATION SEE SHEET E124 —PANEL L1, 400A, 120/208V, POWER ISLAND AP1 25 KVA 83 PHASE SEE DETAIL 1 480:120/240V ' D CONNECT Ot�A FUSED � E133 E599 IH S, 480/208/12OV, 75 x CREW N A XFMR PANEL AP1 - SHELTER MD1, EATON, MAIN SERVICE, 1600A, 480 277V, 3 PHASE (2) 3" RAC (SURFACE MOUNT), 3#350 KCMIL, #1G TO PANEL MD1, II 600A CIRCUIT BREAKER #1 (PROVIDE AS -BUILT CIRCUIT NUMBER) SPARE 1 I G rp z ro I ro i 0 PERMIT CENTER I I nl P L A3-1 M C0 1 1 -1 20 -1 0 20 40 60 x =P `I A3 2-3"C(ABAND) r_j r_j cj � IK s s SCALE IN FEET ,—{ x H H 0 1 2"C,3-1 "C(ABAND) ED 0 E117 El E115 _ E113 p E111 PQ PCI POWER ISLAP SEE DETAIL E '- PANEL AP2 (2) 3" RAC (SURFACE MOUNT), 3#350 KCMIL, #1G TO PANEL MD1, 600A CIRCUIT BREAKER #2 (PROVIDE AS -BUILT CIRCUIT NUMBER) NO LEGEND m TRANSFORMER ® PANELBOARD, 480V GENERAL NOTES 1. NEW CONDUIT ABOVE GRADE TO BE RIGID ALUMINUM. 2. UNLESS OTHERWISE NOTED, WIRE IS STRANDED COPPER, TYPE XHHW-2 INSULATION, MINUMUM #12 AWG FOR POWER & #14 AWG FOR I CONTROL 3. THE FOLLOWING COLOR CODING OF CONDUCTORS SHALL BE OBSERVED ON ALL CIRCUITS 600 VOLTS OR LESS 208/120V 480 277V W PHASE LEFT BUS IN PANEL) BLACK BROWN "B" PHASE CENTER BUS IN PANEL) RED ORANGE "C" PHASE RIGHT BUS IN PANEL) BLUE YELLOW NEUTRAL WHITE GRAY EQUIPMENT GROUND GREEN GREEN ISOLATED GROUND #GRN/YEL #GRN/YEL (*GREEN W/ YELLOW TRACER) 4. LARGE SIZE CONDUCTORS WHICH DO NOT HAVE COLORED JACKETS SHALL BE IDENTIFIED WHEREVER VISIBLE BY APPROPRIATELY COLORED TAPE. 5. ALL UNUSED CONDUIT AND WIRE TO BE REMOVED BACK TO SOURCE, INCLUDING PLUG -ON CIRCUIT BREAKERS ON BUSWAYS. M 6. PERMANENTLY LABEL ALL RECEPTACLES, JUNCTION BOXES, Lu SWITCHES, ETC., WITH PANEL AND CIRCUIT DESIGNATION. t;_j 7. POST REVISED PANEL SCHEDULES IN ELECTRICAL PANELS UPON s COMPLETION OF JOB. d d b' _ I �ooaooa000000aooa0000 z J ® (4) 4" SPARE (1) 1 1/4" LTG. SEE SHEET 2YD-1E8 x HH -8 F 1 331 E504 UTILITY VAULT 444 -LA 1 E133 E503.1 F NJ i 1/2"C (ABANDONED) REFERENCE DRAWINGS 1� 02-127-1 E6 02-127-1E110 02-127-E507 ® 2YD-E504 2YD-E213A, E215A, FOR CMCS WIRING TO ACTUATORS CONSTRUCTION NOTES D AT PANEL MD1, REMOVE (1) 600A AND (2) 200A CIRCUIT BREAKERS, AND REPLACE WITH BLANK PANELS. IN PANEL H3, INSTALL A 70A, 2 POLE CIRCUIT BREAKER, FOR FEEDING CREW SHELTER. PROVIDE NEMA 3R TRANSFORMER FOR CREW SHELTER POWER. CONNECT IT TO 70A BREAKER IN PANEL h3. PROVIDE POWER TO 480V PANEL AT POWER ISLAND. 5. CREATE AS -BUILT PANEL SCHEDULES FOR -ALL PANELBOARDS- IN THIS PROJECT (MD1, L1, A, H3, AP1, AP1-1, AP2, AP2-1) IN STANDARD BOEING EXCEL FORMAT (BLANK FURNISHED ON REQUEST). &r RECEIVED CITY OF TUKWILA G TLC "LCP A3-1" z x 0 PERMIT CENTER I nl P L A3-1 1 o 20 10 0 20 40 60 =P `I A3 2-3"C(ABAND) d d b' _ I �ooaooa000000aooa0000 z J ® (4) 4" SPARE (1) 1 1/4" LTG. SEE SHEET 2YD-1E8 x HH -8 F 1 331 E504 UTILITY VAULT 444 -LA 1 E133 E503.1 F NJ i 1/2"C (ABANDONED) REFERENCE DRAWINGS 1� 02-127-1 E6 02-127-1E110 02-127-E507 ® 2YD-E504 2YD-E213A, E215A, FOR CMCS WIRING TO ACTUATORS CONSTRUCTION NOTES D AT PANEL MD1, REMOVE (1) 600A AND (2) 200A CIRCUIT BREAKERS, AND REPLACE WITH BLANK PANELS. IN PANEL H3, INSTALL A 70A, 2 POLE CIRCUIT BREAKER, FOR FEEDING CREW SHELTER. PROVIDE NEMA 3R TRANSFORMER FOR CREW SHELTER POWER. CONNECT IT TO 70A BREAKER IN PANEL h3. PROVIDE POWER TO 480V PANEL AT POWER ISLAND. 5. CREATE AS -BUILT PANEL SCHEDULES FOR -ALL PANELBOARDS- IN THIS PROJECT (MD1, L1, A, H3, AP1, AP1-1, AP2, AP2-1) IN STANDARD BOEING EXCEL FORMAT (BLANK FURNISHED ON REQUEST). &r RECEIVED CITY OF TUKWILA SYM REVISION BY APPROVED DATE SYM REVISION BY APPROVED DATE O"� 0 ��� Wolll" I.VRRG171 IRCv1Qjv1`I ...... oo��R.... 'too ACCEPTABILITY �.oMAUEY o1.1ss7 480V, MED. VOLTAGE W436846s O O THIS DESIGN AND/OR CHECKED - DRAWING UPDATE FSI 10.11.98 - SITE REDEVELOPMENT - RECORD DRAWING 586456-02 SAZAN/GBG 02.20.13 O ' oFW'' •� O O SPECIFICATION IS APPROVED ENGINEER SHEET A DECOMMISSION BUILDING 2-65 710658-00 BOYE 04.26.01 - AS -BUILT INCORP NO RM 11.11.14'docam : APPROVED BY DEPT. DATE TITtE AIRPLANE STORAGE El 3 B DECOMMISSION BUILDING 2-63 710661-00 BOYE 08.23.01 D AIRPLANE STORAGE W4368468 KNOX 11/18/16 1t�Z2 g c' CHECKED - 2-0 DEMO 586456-02 sAZAN/MN 04.03.09 °O ?'��,�:' 00 APPROVED PLANT 2 JOB No. 710661-00 C SITE REDEVELOPMENT 586456-02 SAZAN/GBG 06.17.11 O°o�Ss/.�0000 APPROVED QRiFI ELECTRICAL MASTER YARD PLANT2, WArl No. 2YD-E133 11/18/16 C G TLC "LCP A3-1" PERMIT CENTER nl P L A3-1 20 10 0 20 40 60 =P `I A3 2-3"C(ABAND) � SCALE IN FEET x REVIEWED ruR 1 2"C,3-1 "C(ABAND) COMPLIANCE WITH ' E117 E116 E115 E114 E113 E112 E111 E110 i N aFRA7®©E E126 E125 E124 E123 E122 E121 E120 E119 E118 0 0 0 o x DEC Q 6 2016 I E135 E134 E133 E132 E131 E130 E129 E128 E127 OUTDOOR LTG Is x a a CONTRACTOR o o �X E144 E143 E142 E141 E140 E139 E138 E137 E136 PNL "OLCP" COMM. VAULT< o City of-Tukrlla I KEY PLAN AwwnI _ _o _ N MATCH LINE - CONTINUATION SEE SHEET E142 SCALE :NONE SYM REVISION BY APPROVED DATE SYM REVISION BY APPROVED DATE O"� 0 ��� Wolll" I.VRRG171 IRCv1Qjv1`I ...... oo��R.... 'too ACCEPTABILITY �.oMAUEY o1.1ss7 480V, MED. VOLTAGE W436846s O O THIS DESIGN AND/OR CHECKED - DRAWING UPDATE FSI 10.11.98 - SITE REDEVELOPMENT - RECORD DRAWING 586456-02 SAZAN/GBG 02.20.13 O ' oFW'' •� O O SPECIFICATION IS APPROVED ENGINEER SHEET A DECOMMISSION BUILDING 2-65 710658-00 BOYE 04.26.01 - AS -BUILT INCORP NO RM 11.11.14'docam : APPROVED BY DEPT. DATE TITtE AIRPLANE STORAGE El 3 B DECOMMISSION BUILDING 2-63 710661-00 BOYE 08.23.01 D AIRPLANE STORAGE W4368468 KNOX 11/18/16 1t�Z2 g c' CHECKED - 2-0 DEMO 586456-02 sAZAN/MN 04.03.09 °O ?'��,�:' 00 APPROVED PLANT 2 JOB No. 710661-00 C SITE REDEVELOPMENT 586456-02 SAZAN/GBG 06.17.11 O°o�Ss/.�0000 APPROVED QRiFI ELECTRICAL MASTER YARD PLANT2, WArl No. 2YD-E133 11/18/16 C (E) (E) (E) 3/4" C TO MPZ (N) SYM JILL V L I /-11 L( G l FOR STAND E599 EAST ELEVATION 1 "CTO WIREWAY ON OPPOSITE (N) IE� POWER ISLAND DETAIL SCALE: 3/8"=1'-0" E33,E83,E133 E599 REVISION BY I APPROVED 1" C TO 480V PANEL ONn1OPPOSITE SIDE APPLIES TO POWER ISLANDS AP1 & AP2 DATE I SYM L u 1 V It V PANEL ON OPPOSITE SIDE (N) RETU @ C( lal D ETAI L SCALE: 3/8"=1'-0" E599 P'11 A / A A P1 f !•1 )% SECTION rB_'� SCALE: 1-1/4"=1'-0" E599 3" EA END 'L ONLY )TH SIDES O Q (:3) (4) (5) (6) O (:8) (9) 10 11 GENERAL NOTES: ANY NEW CONDUIT SHALL BE RIGID ALUMINUM. IF FLEXIBILITY IS REQUIRED, THEN LIQUIDTIGHT FLEXIBLE METAL CONDUIT MAY BE USED. ANY NEW WIRE SHALL BE TYPE XHHW-2. MEGGER TEST ALL NEW AND EXISTING WIRING. WIRE AND CONDUIT SIZES SHALL COMPLY WITH THE NATIONAL ELECTRICAL CODE. WHERE EXISTING NAMEPLATES ARE NOT CORRECT, PROVIDE NEW PHENOLIC NAMEPLATES (WHITE LETTERS ON BLACK) FOR ALL POWER ISLAND EQUIPMENT. NAMEPLATE SHALL INCLUDE THE POWER SOURCE PANEL/CIRCUIT IDENTIFICATION. CREATE AND POST AS -BUILT PANEL SCHEDULES FOR THE 480V PANELS AND THE MINI POWER ZONES, USING A BOEING STANDARD EXCEL FILE FORMAT. PROVIDE EXCEL FILES AND AS -BUILT DRAWINGS TO BOEING. (E) = EXISTING (N) = NEW (M) = MODIFIED EQUIPMENT NOTES: NEMA 5-20R GFCI DUPLEX RECEPTACLE WITH WEATHERPROOF -WHILE -IN -USE CAST ALUMINUM DEEP COVER (INTERMATIC WP1250MVXD). EACH DUPLEX ON AN INDIVIDUAL CIRCUIT. 30A, 600VAC, 3W, 4 POLE RECPT. (CROUSE HINDS #ARE3422) WITH FUSED 30A DISCONNECT SWITCH (NEMA 4X -STAINLESS STEEL) WITH CLASS RK1 OR RK5 FUSES. 60A, 60OV, 3W, 4 POLE RECEPT. (CROUSE -HINDS ARE6424) WITH FUSED 60A DISCONNECT SWITCH. (NEMA 3R OR 4X -STAINLESS STEEL) WITH CLASS RK1 OR RK5 FUSES. 225A, 3 POLE 480V NON -AUTOMATIC CIRCUIT BREAKER (25 KA WITHSTAND RATING) WITH NEMA 3R OR 4X -STAINLESS STEEL ENCLOSURE. 200A, 60OVAC, 3W, 4 POLE RECEPT. CROUSE HINDS #AREA20426. 72" 8 X 8 NEMA 4X STAINLESS STEEL WIRING TROUGH WITH HINGED COVER. 8"x8"x6' WIRING TROUGH WITH HINGED COVER, NEMA 4X STAINLESS STEEL. 20OW, 120V PANEL HEATER WITH THERMOSTAT HOFFMAN #A-DAH2001 FT. SET THERMOSTAT TO 60 DEGREES F. 20A, 120V, TWO GANG EXPLOSION PROOF RECEPTACLES, #CPS152-202SA. EACH RECEPTACLE TO BE ON AN INDIVIDUAL CIRCUIT. PROVIDE GFCI BREAKERS IN THE MINI POWER ZONE FOR THESE CIRCUITS. NEMA 3R 6 -POLE LIGHTING CONTACTOR, FOR (3) 120/24OV, 20A LIGHTING CIRCUITS, WITH HAND -OFF -AUTO SWITCH AND 120V CONTROL, WITH PHOTOCELL FOR AUTOMATIC .CONTROL. PROVIDE PHOTOCELL CONTROL WHEN IN AUTO SWITCH POSITION, AND MANUAL ON WHEN IN HAND POSITION. TWO EXISTING STANDS ARE RELOCATED FROM NORTH BOEING FIELD. SQUARE -D MINI POWER ZONE (COMBINATION 480V BREAKER, TRANSFORMER, AND 120/240V PANELBOARD). 25 KVA RATING, PRIMARY 480V, SECONDARY 120/240V SINGLE PHASE. PROVIDE ANY ADDITIONAL CIRCUIT BREAKERS THAT MIGHT BE NEEDED FOR NEW LOADS. NEW PANEL NAMES WILL BE "API -1" AT POWER ISLAND AP1 OR "AP2-1" AT POWER ISLAND AP2. FOR THE POWER FEED FROM PANEL AP1 TO PANEL AP1-1, ADD AN EXTRA RUN BACK AND FORTH IN THE WIREWAY, TO ADD AN EXTRA 12' OF #4 CONDUCTOR (TOTAL CIRCUIT LENGTH ABOUT 18'). THIS WILL INSURE THAT THE 18 KA RATING OF THE 480V BREAKER IN THE MINI POWER ZONE IS NOT EXCEEDED. GROUND THE TRANSFORMER SECONDARY TO THE COMMON 4/0 GROUNDING ELECTRODE CONDUCTOR. 480V PANEL "AP1" AT POWER ISLAND AP1 (CLOSEST TO PANEL MD1) OR 12-"AP2" AT POWER ISLAND AP2. EACH PANEL WILL BE SERVED BY (2) 3" CONDUITS WITH 350 KCMIL CONDUCTORS. PROVIDE RAINTIGHT HOLE COVERS FOR ALL UNUSED HOLES IF EXISTING PANEL ENCLOSURE IS REUSED. 2x`1411-2)) FOR EXISTING PANELBOARD WITH 800A MAIN LUG INTERIOR: RELOCATE CIRCUIT BREAKERS AS NECESSARY TO ENSURE THAT NO CIRCUIT BREAKER OPERATING HANDLES WILL BE ABOVE 6'-7" FROM THE GROUND LEVEL. ADD ADDITIONAL BREAKERS AS NECESSARY FOR NEW LOADS. FOR EXISTING PANELBOARD WITH 400A MAIN LUG INTERIOR: EITHER REPLACE PANEL INTERIOR WITH 800A MAIN LUG INTERIOR (SAME AS EXISTING 800A REVIEwi=,- j,-6,PANEL), OR PROVIDE NEW PANELBOARD WITH THE SAME TYPE OF COMPLIANDE I'll ENCLOSURE. EXISTING CIRCUIT BREAKERS ARE PERMITTED TO BE REUSED. NFPA 70 - flEC LOCATE CIRCUIT BREAKERS TO ENSURE THAT NO CIRCUIT BREAKER OPERATING HANDLES ARE ABOVE 6'-7" FROM THE GROUND LEVEL. ADD ADDITIONAL BREAKERS AS NECESSARY FOR NEW LOADS. INTERRUPTING EIEC O 6 2016 RATING 25KA. RECEIVED ! CITY OF TUKWILA City oiTult�ril�. _ NUV 2 9 2016 BUIL®Ii�G Dl v iSICCv fAm% a- DRAWN DATESUBTITLE REVISION BY APPROVED DATE Q� R R oo ACCEPTABILITY W. KNOX 10 13/16 IS DESIGDOR CHECKED PLANT 2 AIRPLANE STORAGE SPECIFICATION rISAAPPROVED M. KNOPP 10/13/16 POWER ISLAND DETAIL Q �0 TITLE : Q APPROVED BY DEPT. DATE �l CHECKED APPROVED PLANT 2 YARD OVAL � o o'f, 0 0o APPROVED ELECTRICAL MASTER CURRENT PERMIT CENTER RIO' 11/18/16 E599 JOB NO. COMP NO. W4558717 PLANT 2, WA DWG NO. 02 -YD -E599 --------------- I I x3/16 I z I00� w K3/16 n 1 1/2" CHAMFER - 5S5667 z 1/2 x o U 00 rD S567 OF SLAB l ) 1 PORTABLE LIGHT POST S567 SECTION A SCALE: 1/4"=1'-0" E36, E45, E46, E47 S567 SEAL WELD 3/16 2"0 HOLE -GRIND SMOOTH AND RADIUS CORNERS SECTION SCALE: 1 "=1'-0 DETAIL SCALE: 1"=l'—O" SYM REVISION A AIRPLANE STALL EXPANSION - IFP B AIRPLANE STALL EXPANSION - IFP C AIRPLANE STALL EXPANSION - IFC PL1/8 CAP PLATE WITH 4"0 HAND HOLE AND 5"0 REMOVABLE CAP PLATE. SEE FOR REMOVABLE A SIM CAP U�> S567 S568 2"0 SCHEDULE 40 PIPE TYP 2"0 HOLE -GRIND SMOOTH AND RADIUS (TYP AT 2"0 PIPE) L HAND HOLE W/ 4"0 OVABLE CAP PLATE AT -H 22"0 PIPE, SEE A S567 S568 HSS4 tB S567 PL1/2 SPLICE PLATE (TYPICAL) SEE 7 S567 5S567 GENERAL NOTES BY APPROVED DATE SYM W3689354 HG NEM 06.21.16 RED AND WHITE BANDS, 5'-0" WIDTH, RED ON TOP. W3689354 HG NEM 08.31.16 LL _/ W36893541 HG NEM 1 10.05.16 B GENERAL NOTES MOVABLE LIGHT POLE FOUNDATION B PRIME AND PAINT ALL STEEL LIGHT BRACKETS TO BE FEDERAL B S. DUFFY ANCHOR ASSEMBLY ,� 2'-6 3/4" X11. 4 1/2"I� 2'-6 3/4" #4 VERTICAL 1 r 6n 1 i_6n (10) PLACES 1 1/2" CHAMFER TYP #4 BARS `� #4 VERTICAL B �- (3#4 TIES 14 #4 12 12 BUILDING PAPE SEPARATION AT SLAB B HSS14x6x3/8 FORK POCKETS. 0 cV n I I I I 3 "�II�I" B "' I I I I (4) #4 BARS (-1 I I TYPICAL ® 3 LEVELS EA. WAY 1 1 to ` of ANCHOR ASSEMBLY I I ° ° I 1 SEE � I l I I S567 I I I N o ► I n I I o �4 TIES I - 2"0 SCHEDULE 40 PIPE r LJ L- I !-1 I I_ p 1 SCALE: 1"=l'—O" S567 REVISION BY APPROVED DATE PL1/8 LAP (SEAL WELD) TYPICAL b SCHEDULE PIPE Z) PLACES PL1/8 CAP (SEAL WELD) TYPICAL BASE PLATE D ETAI L SCALE: 3"=l'—O" S567 D M r r r DETAIL SCALE: 1 "=1'-0 PL1 1/8x18x1'-6" BASE PLATE B 1/4 1/4 J/ /4 PROVIDE WELD AT TOP OF PL 1/4 _ 3/8 TO SEAL 5/16 1 1/2"0 DRAIN HOLE PROVIDE WIRE BIRD AND RODENT SCREEN FASTEN W/ (4) SCREWS, SEE FOR SCREW SIM INFORMATION S567 S568 (8) �1/ HOLESFORS' (8) 1 1/8-0 F1554 GRADE 55 ANCHOR RODS HSS7 POST Pk (4) 13/16"0 HOLES FOR (4) 3/4"0 A325 BOLTS PL1/2 SPLICE PLATE 4"0 HOLE (GRIND SMOOTH) D LEGEND F1554 ICHOR B GENERAL NOTES 1. PRIME AND PAINT ALL STEEL LIGHT BRACKETS TO BE FEDERAL THIS DESIGN AND/OR SPECIFICATION IS APPROVED S. DUFFY STANDARD SAFETY COLORS WHITE, POLES TO BE ALTERNATING PL3/8x18x1'-6" RED AND WHITE BANDS, 5'-0" WIDTH, RED ON TOP. APPROVED BY SEE 09 90 00. DATE LL _/ PROVIDE FORK POCKETS: HSS14x6x3/8x6'-6" LONG. TITLE AIRPLANE STALL EXPANSION NORTH BOEING FIELD ISTRUCTURAL MASTER NORTH BOEING FIELD l PROVIDE 1/4" CLOSED CELL SILICONE SPONGE BY BELLO FOAM OR APPROVED EQUAL ADHERED TO COVER PLATES. MANUFACTURER S" DUCECKEFFY TO PROVIDE PRESSURE SENSITIVE ADHESIVE. (8) 1 1/4-0 HOLES FOR (8) 1 1/8"0 ® INSTALL POLE PLUMB. RE -ADJUST TO PLUMB AS NECESSARY ANCHOR RODS 06.21.16 AFTER EACH RELOCATION. 5. SEE ELECTRICAL DRAWINGS FOR LOCATION AND ELECTRICAL CONNECTIONS. 3 6. FOR GROUNDING SEE ELECTRICAL DRAWINGS E86, E96, E97, AND 8 S567 E> MOVABLE LIGHT POLE FOUNDATION DESIGN LOADS: ULTIMATE DESIGN WIND SPEED Vult = 110 PMH, EXPOSURE C. OVERTURNING MOMENT AT TOP OF MOVABLE FOUNDATION = 51.0 FT* KIPS (LRFD) B J DESIGN BASED ON (12) KIM LIGHTNING ALT 240 LUMINARIES. , J REFERENCE DRAWINGS 03-YD-S2F STRUCTURAL GENERAL NOTES CONSTRUCTION NOTES RECEIVED CITY OF TUKWILA NOV 2 9 2016 REVIEW -EL_ PERMIT CENTER OMPLIANC NFPA70--€IFFY Dru 0 6 ?w FINAL APPROVAL PENDING City of Tuk�ril: KING COUNTY REVIEW UIL®ING ®IVl .. WBS 2.0&2.1 - B & C LINE ISSUED FOR PL3/8 CONSTRUCTION Our difference DETAIL D ETA I L8 I is engineered. www.harrisgroup.com SCALE: 3"=1'-0" S567 SCALE. 3"=l'—O" S567 op PROJECT NO: 12592.00 G)�waF wAsDRAWN �lrj. ACCEPTABILITY S. SAMSON D04.22.16 SUBTITLE CURRENT REVISION SYMBOL DATE CHECKED LIGHT POLE SECTIONS AND DETAILS W3689354 C 10.05.16 5567 W3689354 COMP N0. 03—YD—S567 c t A�O��L2�,����' SSIONAL� 09/28/16 4: 4 PM THIS DESIGN AND/OR SPECIFICATION IS APPROVED S. DUFFY 06.21.16 APPROVED BY DEPT. DATE ENGINEER A. WARNER 06.21.16 TITLE AIRPLANE STALL EXPANSION NORTH BOEING FIELD ISTRUCTURAL MASTER NORTH BOEING FIELD S" DUCECKEFFY 06.21.16 APPROVED D. KYLE 06.21.16 NPMANDELENAKIS 1 06.21.16 5567 W3689354 COMP N0. 03—YD—S567 DETAIL SCALE: 3"=1'-0 DRILL AND TAP (4) HOLES FOR #10-24 HEX SCREW, TYPE 316 STAINLESS STEEL PL1/8x5"x0'-7" COVER PLATE 4"x0'-6" VERTICAL HAND HOLE (OBLONG SHAPE) S5671S568 PL1/8x4"0 CAP PLATE a> 3" HAND I ,2) HOLES FOR :AD SCREW -ESS STEEL SECTION a SCALE: 3"=1'-0" S567 S568 GENERAL NOTES 1. PRIME AND PAINT ALL STEEL LIGHT BRACKETS TO BE WHITE, POLES TO BE ALTERNATING RED AND WHITE BANDS, 5'-0" WIDTH, RED ON TOP. 2� PROVIDE 1/4" CLOSED CELL SILICONE SPONGE BY BELLO FOAM OR APPROVED EQUAL ADHERED TO COVER PLATES. MANUFACTURER TO PROVIDE PRESSURE SENSITIVE ADHESIVE. REFERENCE DRAWINGS 03-YD-S2F STRUCTURAL GENERAL NOTES REVIEWED OMPLIANCE WITH NFPA 70 c NFC, t DEC 0 6 2016 i City of.TuWila ..yt 3UILDING DIVISI0t°r° RECEIVED CITY OF TUKWILA NOV 2 9 2016 PERMIT CENTER FINAL APPROVAL PENDING KING COUNTY REVIEW WBS 2.0&2.1 - B & C LINE ISSUED FOR CONSTRUCTION I Our difference is engineered. ' www.harrisgroup.com PROJECT NO: 12592.00 SAS f ACCEPTABILITY DRAWN ON DD7.27.16 SUBTITLE ��++ //�� �+ /'+ �+ pp �+ CURRENT REVISION SYMBOL R DATE SYM REVISION BY APPROVED DATE SYM REVISION BY APPROVED DATE ���oF �' ���' THIS DESIGN AND/OR CHECKED LIGHT PULE SECTIONS AND DETAILS W3689354 LJ 10'05'16 A AIRPLANE STALL EXPANSION IFP W3689354 HIS NEM 08.31.16 02 SPECIFICATION IS APPROVED A. WARNER 08.31.18 SHEET ENGINEER B AIRPLANE STALL EXPANSION - IFC W3689354 HG TITLE AIRPLANE STALL EXPANSION NEM 10.05.16 APPROVED BY DEPT. DATE A. WARNER 08.31.16�CHECKEDS. S568�o��'SS+ L2 � �� 08.31.16 NORTH BOEING FIELD JOB NO. COMP NO. A ROVED ONAL W3689354 09i28i16 4: 4 Piv1 N MANDELENAKIS 08.31.16 STRUCTURAL MASTER NORTH BOEING FIELD °wc No. 03—YD—S568 = OEING COMMERCIAL IRPLANES PLANT 2 •SOUTH AIRPLANE STORAGE PROJECT #W4368468 VICINITY MAP CODE SUMMARY DRAWING INDEX manges snail to the Of Mtork w thou,, Rrcr approval o f Tukwila Building Division, P�+CTL: GVIJ:L J %•riff require a new plan submittst and may include additional plan review tees. PROJECT SUMMARY DESCRIPTION OF WORK: PROVIDE STORAGE PARKING FOR (8) 737 AIRPLANES. POWER TO BE PROVIDED FROM (2) POWER ISLANDS. SECURITY LIGHTING TO BE PROVIDED FROM (5) LIGHT POLES. GROUNDING LOCATIONS PROVIDED FOR AIRCRAFT STATIC GROUND, CONTRACTOR: WASHINGTON PATRIOT (GENERAL) SEQUOYAH ELECTRIC (ELECTRICAL) ELECTRICAL ENGINEER: WALTER R. KNOX, PE BOEING FACILITIES ENGINEERING 206-662-6444 SITE ADDRESS: 7775 EAST MARGINAL WAY SOUTH TUKWILA, WA OWNER: THE BOEING COMPANY SHARED SERVICES GROUP P.O. BOX 3707, M/C: 2R-78 SEATTLE, WA. 98124-2207 OWNER CONTACT: JOHN MURDOCH 253-740-0214 KING COUNTY PARCEL NO. 3324049002 0001600020 LE COPY Permit No.. �1'1 � Plan raTla ' nonroval is subject to errors and o�issiors. Approval of construction documents does riot au ho i-3 the violation of any adopted cods or ordinance. 13=71 ;t of approved Field Copy and conditions is acknowledgei: By Date: City of TukWil$ BUILDING DIVISION REVIEWED FU-. COMPLIANCE WITS -I NEPA 70 - NEC DEC 0 6 2016 �'> wf� City of-TukWila BUILDING DIVISION RECEIVED CITY OF TUKWI A NOV 2 9 2016 PERMIT CENT9R O,` vR R --Q�0 ACCEPTABILITY ulzAwN uarE SUBTITLE COVER SHEET CURRENT REVISION SYMBOL _ DATE 11/18/16 SYM REVISION BY APPROVED DATE SYM REVISION BY APPROVED DATE O O! O O OD THIS DESIGN AND/OR CHECKED �. SPECIFlCATION IS APPROVED SHEET N Z o APPROVED BY DEPT. DATE ENGINEER TITLE CHECKED PLANT 2 YARD EO APPROVED JOB NO. COMP NO. oo W4368468 �\o°o f APPROVED DWG N0. 0 L 0 ij (,� ELECTRICAL MASTER PLANT 2 02—YD—EO SHEET NO. SHEET NAME REVISION 02—YD—EO COVER SHEET ORIG 02—YD—V21 E4 ONE—LINE DIAGRAM — VAULT 21 G 02—YD—MD1E4 ONE—LINE DIAGRAM — PANEL MD1 ORIG SE �A, N1 IT 02—YD—E32 LIGHTING C Rcui(tJ FOR: 02—YD—E33 LIGHTING C ��/� 02—YD—E82 120/208V & GROUNDING A 2 Mechanical 02—YD—E83 120/208V & GROUNDING A ❑ fE ectr;cat 02—YD—E133 48OV, MED. VOLTAGE D rnbing 02—YD—E599 POWER ISLAND DETAIL ORIG �8'PP tjd'Gas Piping 03—YD—S567 LIGHT POLE SECTIONS AND DETAILS C City of Tuhwilla 03—YD—S568 LIGHT POLE SECTIONS AND DETAILS B WILDiI IG DIVISION manges snail to the Of Mtork w thou,, Rrcr approval o f Tukwila Building Division, P�+CTL: GVIJ:L J %•riff require a new plan submittst and may include additional plan review tees. PROJECT SUMMARY DESCRIPTION OF WORK: PROVIDE STORAGE PARKING FOR (8) 737 AIRPLANES. POWER TO BE PROVIDED FROM (2) POWER ISLANDS. SECURITY LIGHTING TO BE PROVIDED FROM (5) LIGHT POLES. GROUNDING LOCATIONS PROVIDED FOR AIRCRAFT STATIC GROUND, CONTRACTOR: WASHINGTON PATRIOT (GENERAL) SEQUOYAH ELECTRIC (ELECTRICAL) ELECTRICAL ENGINEER: WALTER R. KNOX, PE BOEING FACILITIES ENGINEERING 206-662-6444 SITE ADDRESS: 7775 EAST MARGINAL WAY SOUTH TUKWILA, WA OWNER: THE BOEING COMPANY SHARED SERVICES GROUP P.O. BOX 3707, M/C: 2R-78 SEATTLE, WA. 98124-2207 OWNER CONTACT: JOHN MURDOCH 253-740-0214 KING COUNTY PARCEL NO. 3324049002 0001600020 LE COPY Permit No.. �1'1 � Plan raTla ' nonroval is subject to errors and o�issiors. Approval of construction documents does riot au ho i-3 the violation of any adopted cods or ordinance. 13=71 ;t of approved Field Copy and conditions is acknowledgei: By Date: City of TukWil$ BUILDING DIVISION REVIEWED FU-. COMPLIANCE WITS -I NEPA 70 - NEC DEC 0 6 2016 �'> wf� City of-TukWila BUILDING DIVISION RECEIVED CITY OF TUKWI A NOV 2 9 2016 PERMIT CENT9R O,` vR R --Q�0 ACCEPTABILITY ulzAwN uarE SUBTITLE COVER SHEET CURRENT REVISION SYMBOL _ DATE 11/18/16 SYM REVISION BY APPROVED DATE SYM REVISION BY APPROVED DATE O O! O O OD THIS DESIGN AND/OR CHECKED �. SPECIFlCATION IS APPROVED SHEET N Z o APPROVED BY DEPT. DATE ENGINEER TITLE CHECKED PLANT 2 YARD EO APPROVED JOB NO. COMP NO. oo W4368468 �\o°o f APPROVED DWG N0. 0 L 0 ij (,� ELECTRICAL MASTER PLANT 2 02—YD—EO F_ 26KV INCOMING LINE FROM SEATTLE CITY LIGHT S&C ELECTRONIC FUSE 1 CAT. #7010-C40S4T3D8 3'x`2 �� 26.4KV-13.8KV 1 7.5 MVA Z=6.41% 3 2 Z GROUNDING RESISTOR 8000V, 200A, 40 OHM, 10 SEC, 760 DEGREE RISE CO -9 51G TAP: 1 200:5 TD: 3 INST: 39 — i — i 0.5E, 15KV 3AA, 250V r---------- (3) I I METERING PT'S SEATTLE CITY LIGHT 14400-120V ( METERING EQUIPMENT I I I I METERING ----------I (3) I I I I I .2 KV I MCOV r—j I I i i 0.5E, 15KV CPT I 13800-120/240V I (2) PT'S n 15 KVA 14400-120V A I I I ryF I 600:5 TS PM AS AM 3A, 250V MR (3) i 0-600A -M STATION 52 86 POWER 12-M 20/240 u i 100A 600:5 50 MR (3) 51 (3) CO -9 TAP: 3 TD: 8 INST: 39 vsvM 0-15KV SCALE 0-125V COIL AC PANELBOARD BREAKER BREIKER BREAKER BREAKER DC PANELBOARD 52-7 52-5 52-3 52-1 PREPARED SPACE - - - BREAKER INCOMING LINE BOEING 52-M STORAGE MAIN BREAKER SEATTLE CITY LIGHT COMPARTMENT PT'S & CPT METERING COMPARTMENT BATTERIES BREAKER BRE/.KER BREAKER BREAKER & 52-8 52-6 52-4 52-2 BATTERY CHARGER VAULT 20 - - - (T1E) (FUTURE) FRONT VIEW FROM AISLE MAIN BUS - 13.8KV, 1200A, 3PH, 3W LEGEND 5 G5 51G @ PROTECTIVE RELAY, ANSI DEVICE NUMBER SHOWN (3) 600:5 MULTI-RA110 CURRENT TRANSFORMER, RATIO AS SHOWN, MR 50:5— ZERO SEQUENCE CURRENT TRASFORMER, RATIO AS SHOWN As vs FTS]AMMETER SWITCH, VOLTMETER SWITCH, TEST SWITCH PM POWER MONITOR (SQ. D. POWER LOGIC) AM O AMMETER, VOLTMETER, SCALE AS SHOWN 0-600A 0 LOAD CABLE TERMINATION POINT G SEE SHEET E1 FOR ADDITIONAL SYMBOLS DESCRIPTION. GENERAL NOTES REFERENCE DRAWINGS CONSTRUCTION NOTES CONTRACTOR IS TO HAVE EATON ENGINEERING SERVICES VERIFY AND EVALUATE RELAY SETTINGS FOR THIS CIRCUIT BREAKER, AS PART OF THE SHORT CIRCUIT/COORDINATION/ARC FLASH STUDY, AND J IMPLEMENT ANY CHANGES, IF REQUIRED. J-0 V c0-11 CO -9 c0-11 CO -11 CO -11 CO -11 CO -11 TAP: 2 TAP: 2 TAP: 2 TAP: 2 TAP: 2 TAP: 2 TAP: 2 TD: 2 TD: 4 TD: 6 TD: 2 TD: 2 TD: 2 i TD: 2 INST: 15 INST: 30 INST: 144 INST: 15 INST: 15 INST: 15 i INST: 15 50 50 50 50 50 50 __a _ 50_} i __a _ 50 } 600:5 600:5 600:5 600:5 600:5 600:5 600:5 , , 600:5 MR MR MR MR MR MR MR (3) 51 MR (3) 51 (3) 51 (3) 51 (3) 51 (3) 51 (3) . �1,. i '-T (3) I (3) 1 (3) 1 (3) 1 (3) 1(3) 1 (3) i (3)(3) . T I I I I I I ,. I i FUTURE I--) 1200.0 52 52-1 52-2 52-3 �_— 52-4 �_— 52-5 -- 52-6 f-- 52-7 �', f__ , _t - -� -� J -# KIRK -KEY uK L 1200.0 I 1200.0 I 1200.0 I 1200.0 1 1200.0 I 1200.0 I 1200.0 W� I I INTERLOCK I W TS PM AS AM 600:5 TS PM AS AM r- r--, r--, 600:5 TS PM AS AM 600:5 600:5 TS PM AS AM 600:5 TS PM AS AM 600:5 TS PM AS AM 600: 5 ---- (- i TS r PM r AS ,- AM , I 600: 5 -- j- ; TS r PM -1 AS F-4 AM ; MR MRI 0-600.0 MR I 0-600A MR I 0-600A MR I 0-600A MR I 0-600.0 MR I L_ -J L --J 600A I MR I L_ -J L__J 0-600A I I I I I I 0- 1 1 0-600A 7 I I I i I I I I I 50:5 50 51 50:5 50 5 50:5 50 5 50:5 50 5 50:5 50 5 50:5 50 51 50:5 ' 50 G G G G 50:551,; CO -11 Co -11 - -' -' ----' co -11 1 CO -11 ( co -11 ( co -11 1 CO -11 TAP: 1.5 TAP: 2 ( TAP: 1 f TAP: 1.5 TAP: 1.5 TAP: 1.5 1I TAP: 1.5 j TD: 2 1 TD: 3 1 TD: 1 I TD: 2 I TD: 2 1 TD: 2 1 I 1 TD: 2 INST: 39 INST: 39 INST: 5 INST: 39 INST: 39 INST: 39 FEEDER 21-8 INST: 39 FEEDER 21-1 FEEDER 21-2 FEEDER 21-3 FEEDER 21-4 FEEDER 21-5 FEEDER 21-6 PREPARED FEEDER 21-7 SPARE SPARE 3#4/0, #1 GND 3#500MCM 3#500MCM, #4/0 GND SPARE SPACE ONLY (2) SETS 3 #500kcmil, 1 #4/OGND (FORMERLY FED VAULT 5) TO VAULT 52, SWITCHES SWITCH V113 FEEDING 1500 KVA PAD MOUNT TO VAULT 50/SUB 50A VAULT 20 (TIE) SW1-1 & SW2-1 TRANSFOMER FOR 1600A PANEL MD1 & VAULT 51/SUB 51A (FUTURE) .� � RECEIVED ONE -LINE DIAGRAM - VAULT 21DEC SCALE: NONE V21 E4 ��� � 6 ���6 NOV 2 9 2016 City ofTUE FIE PERMIT CENTER I3U11-DMCURe of- BUILO O RAW A SUBTITLE SYMBOL DATE SYM REVISION BY APPROVED DATE SYM REVISION BY APPROVED DATE p� R R, oo ACCEPTABILITY K. READ 10/8/98 ONE -LINE DIAGRAM -VAULT 21 o �............. oW4368468 11/18/16 A REFEED VAULT 5 AND VAULT 9 981004 KR CS 10/13/98 F PLANT 2 ELECTRICAL POWER UPGRADE 15644/20111 CEI PWJ 11.11.13 Op ;''pFWASy� 2 o THIS DESIGN AND/OR C C SHEET p Q,: `F, ti • O O SPECIRCATION IS APPROVED ENGINEER B ADD VAULT 50 FEEDER FOR BUILDING 2-81 972197 KR RECORD DRAWING 15644/20111 CEI 07.24.15 ® R _ APPROVED BY DEPT. DATE K. READ 10/8/98 1iTLE PLANT 2 ELECTRICAL POWER UPGRADE �� C RECORD DRAWING J#982190-00 HGI/SDB 03.1.01 G AIRPLANE STORAGE W4368468 KNOX 11/18/16 ,��Zj° CH KE 1 E4 D AC DEMO 2-62 J#120253-00 KNOX CAS 06.12.02 O p C. STEWART 10 13 98 VAULT 2 1 JOB NO. COMP NO. 00 P „ED 716945-00 STUDY DATA TEB 02.15.10 0o�ONAL Eo0� AP RovED ELECTRICAL MASTER YARD PLANT 2 WA DWG NO. 02 -YD -V21 E4 E AS BUILT ARC FLASH A O O L SYM I REVISION ORIG I AIRPLANE STORAGE BY I APPROVED I DATE I SYM W43684681 KNOX 1 111/18/161 REVISION TO VAULT 21, FEEDER 21-4 (SEE DWG: 02 -YD V21 E4) 0 0 MANHOLE E MANHOLE F (LOAD BREAK CONNECTORS) 01 120/208V 15KV, 600A "A" 0 (LEFT BUS IN PANEL) BLACK HV SW Vi 13 "B" 0 CENTER BUS IN PANEL) 100A Q "C" 0RIGHT BUS IN PANEL) BLUE 13.8KV -+,. 1500 KVA 3/0 G.E.C. 480V277V EQUIPMENT GROUND ??6.519 Z O ISOLATED GROUND LOCATED OUTDOORS N. OF BLDG. 2-80 SEE 02 -YD -E133 LEGEND GENERAL NOTES 1. CONDUIT TO BE 1/2" EMT UNLESS OTHERWISE NOTED. 2. ALL WIRE TO BE #12 THHN UNLESS OTHERWISE NOTED. 3. THE FOLLOWING COLOR CODING OF CONDUCTORS SHALL BE OBSERVED ON ALL CIRCUITS 600 -VOLTS OR LESS. LARGE SIZE CONDUCTORS SHALL BE IDENTIFIED WITH COLORED TAPE WHERE EVER VISIBLE. 5. INSTALL NEW OR REVISED PANEL SCHEDULES UPON COMPLETION OF JOB. 120/208V 277/480V "A" 0 (LEFT BUS IN PANEL) BLACK BROWN "B" 0 CENTER BUS IN PANEL) RED ORANGE "C" 0RIGHT BUS IN PANEL) BLUE YELLOW NEUTRAL WHITE GRAY EQUIPMENT GROUND GREEN SIZE ISOLATED GROUND GRN/YEL GRN/YEL 4. DYMO LABEL ALL RECEPTACLES, JUNCTION BOXES, SWITCHES,ETC., WITH CIRCUIT IDENTIFICATION. 4" 5. INSTALL NEW OR REVISED PANEL SCHEDULES UPON COMPLETION OF JOB. -25KVA 480-120/240V N G.E.C. - #4' IN 1/2" PNL. A SCH. 80 100A PVC 120/240V TO 4/0 SYS. 1 PH 3W GND. 1,a CREW SHELTER =p 75KVA 480-208Y/120V 'th X }j 200A, FUSED (PART OF MPZ) I (PART OF MPZ) ULI 25KVA 25KVA — 480-120/240V _ 480-120/240V CONSTRUCTION NOTES AP2-1 1600A MDLO 125A G.E.C. - #4 120/240V IN 1/2" 11PH, IPH, 3W IN 1/2" SCH. 80 SCH. 80 (PARTOF MPZ, ) PVC (PARTOF MPZ) PVC TO 4/0 SYS. TO 4/0 SYS. 480Y/277V GND. SIZE PHASE NEUTRAL GND IG 3 PH, 4W 1 4" 3-500KCMIL � REMOVE (1) 600A AND (2) 200A CIRCUIT BREAKERS AND 2� 2 4" 3-250KCMIL PROVIDE BLANK COVERS. (LIMIT SUM OF BREAKERS TO O 30 1600A 4 4" O5 1600A). 4O 5 0 2 2" � REPLACE EXISTING FEEDERS (2 SETS OF 4 - 500 KCMIL) WITH 2 SETS OF 600 KCMIL (NECESSARY TO COMPLY WITH #1 O 600A 2 3" 3-350KCMIL #1 60 70A 3 D 1" 2#4 NEC 240.21(C)(1)b). 7 110A 1 PROVIDE POWER TO POWER ISLANDS. SEE 02 -YD -E599. 2#1 PNL. H3 #6 PNL. AP1 PNL. AP2 ® PROVIDE TRANSFORMER. PROVIDE POWER TO EXISTING 400A 800A MLO 600A MLO PANEL A IN CREW SHELTER, 480V 480V 480V 3 PH, 3W 3 PH, 3W 3 PH, 3W 5. HIRE THE SERVICES OF EATON ENGINEERING SERVICES, TO DO A SHORT CIRCUIT AND ARC FLASH STUDY, BY ADDING O6 6 60 ON TO THE EXISTING BOEING SKM MODEL. PROVIDE NEW ARC FLASH LABELS FOR THE MEDIUM VOLTAGE SWITCH V113, o AND FOR ALL PANELBOARDS SHOWN ON THIS DRAWING. A PREVIOUS EATON STUDY TQSISE0009436.1 WAS DONE WHEN d PANELS MD1, H3 AND L1 WERE ORIGINALLY INSTALLED. PROVIDE THE STUDY IN ELECTRONIC FORMAT TO BOEING. -25KVA 480-120/240V N G.E.C. - #4' IN 1/2" PNL. A SCH. 80 100A PVC 120/240V TO 4/0 SYS. 1 PH 3W GND. 1,a CREW SHELTER =p 75KVA 480-208Y/120V 'th X }j 200A, FUSED (PART OF MPZ) I (PART OF MPZ) ULI 25KVA 25KVA — 480-120/240V _ 480-120/240V AP1-1 AP2-1 125A G.E.C. - #4 120/240V 125A G.E.C. - #4 120/240V IN 1/2" 11PH, IPH, 3W IN 1/2" SCH. 80 SCH. 80 (PARTOF MPZ, ) PVC (PARTOF MPZ) PVC TO 4/0 SYS. TO 4/0 SYS. GND. GND. ONE LINE DIAGRAM- PANEL MD1 SCALE: NONE BY I APPROVED I DATE REVIEWED (;OMPLIANGE WiTh NFPA70 - FIFO DEC 0 6 7016 City of Tukvifla BUILDING DIVISI01"O: DRAWN DATE SUBTru ACCEPTABILITY RFMORALES 10.07.16 THIS DESIGN AND/OR CHECKED SPECIFICATION IS APPROVED ENGINEER ME APPROVED BY I DEPT. I DATE ELECTICAL RECEIVED CITY OF TUKWILA NOV 2 9 2016 PERMIT CENTER. 1N'7777. ,10 ONE LINE DIAGRAM - PANEL MD1 02 -YD COL. X PLANT2, WA R I GI DATE 11/18/16 02 -YD -MDI E4 CONDUCTORS PER CONDUIT TYPE RATINGCONDUIT QTY SIZE PHASE NEUTRAL GND IG 10 1 4" 3-500KCMIL 2� 2 4" 3-250KCMIL 30 1600A 4 4" 4-600KCMIL 4O 400A 2 2" 3#4/0 #1 O 600A 2 3" 3-350KCMIL #1 60 70A 1 1" 2#4 #8 7 110A 1 1 1/4" 2#1 1 #1 #6 1N'7777. ,10 ONE LINE DIAGRAM - PANEL MD1 02 -YD COL. X PLANT2, WA R I GI DATE 11/18/16 02 -YD -MDI E4 henr('u I Inif7 - rMITIM IATlr)M CFF CNFFT 1791 SYM REVISION — 2-4X DEMO A SITE REDEVELOPMENT B SITE REDEVELOPMENT — DCN #10 — SITE REDEVELOPMENT — RECORD DRAWING AS—BUILT INCORP REVISION F MATCH LINE - CONTINUATION SEE SHEET E41 BY I APPROVED I DATE W43684681 KNOX 1 111/18/16 �< R. . F WAS'. lti �Fcisr��� I; REVIEWED SOH COMPLIANCE WITH' NFPA 70 d NEC DEC 0 6 2016 City of Tukwila I BUILDING DIVISIQ ACCEPTABILITY 1J.OMALLEY THIS DESIGN AND/OR SPECIFICATION IS APPROVED APPROVED BY I DEPT. I DATE 01.16.97 ELECTRICAL MASTER A 400W HI C TYP E32 I E504 LEGEND -° POLE MOUNTED - DOUBLE HEAD LUMINAIRE POLE MOUNTED - SINGLE HEAD LUMINAIRE BOLLARD UTILITY VAULT —AA1l 40 -\ LIGHTING FIXTURE IDENTIFIER LIGHT POLE MOUNTED TO 6.5'x6.5x3.5' CONCRETE BASE, FORKLIFT PORTABLE. WITH (6) 300W, 37 DEGREE FLOODLIGHTS, E-CONOLIGHT #E-HL9S30NSZ ON THE TOP RUNGS. TILT ALL FIXTURES DOWN 10 DEGREES FROM VERTICAL. ROTATED FIXTURES ARE AT 30 DEGREES ROTATION FROM STRAIGHT AHEAD. SEE POLE DETAIL A ON DRAWING E47 5567 03 -YD -S567 GENERAL NOTES 1. CONDUIT TO BE RIGID ALUMINUM UNLESS OTHERWISE NOTED. 2. UNLESS OTHERWISE NOTED, WIRE IS STRANDED COPPER, TYPE XHHW-2 INSULATION, MINIMUM SIZE #12 FOR POWER & #14 AWG FOR CONTROL. BY APPROVED DATE SYM SEE 586456-02 SAZAN/MN E10 04.03.09 C AIRPLANE STORAGE 586456-02 SAZAN/GBG E21 06.17.11 A 40C�W H E18 586456-02 SAZAN/GBG IDENTIFIED WITH COLORED TAPE WHEREVER VISIBLE: 208Y 120V 480Y 277V 03.02.12 E31 E30 586456-02 SAZAN/GBG E27 02.20.13 BROWN E42 E41 DP W 10/30/141 ORANGE 1 REVISION F MATCH LINE - CONTINUATION SEE SHEET E41 BY I APPROVED I DATE W43684681 KNOX 1 111/18/16 �< R. . F WAS'. lti �Fcisr��� I; REVIEWED SOH COMPLIANCE WITH' NFPA 70 d NEC DEC 0 6 2016 City of Tukwila I BUILDING DIVISIQ ACCEPTABILITY 1J.OMALLEY THIS DESIGN AND/OR SPECIFICATION IS APPROVED APPROVED BY I DEPT. I DATE 01.16.97 ELECTRICAL MASTER A 400W HI C TYP E32 I E504 LEGEND -° POLE MOUNTED - DOUBLE HEAD LUMINAIRE POLE MOUNTED - SINGLE HEAD LUMINAIRE BOLLARD UTILITY VAULT —AA1l 40 -\ LIGHTING FIXTURE IDENTIFIER LIGHT POLE MOUNTED TO 6.5'x6.5x3.5' CONCRETE BASE, FORKLIFT PORTABLE. WITH (6) 300W, 37 DEGREE FLOODLIGHTS, E-CONOLIGHT #E-HL9S30NSZ ON THE TOP RUNGS. TILT ALL FIXTURES DOWN 10 DEGREES FROM VERTICAL. ROTATED FIXTURES ARE AT 30 DEGREES ROTATION FROM STRAIGHT AHEAD. SEE POLE DETAIL A ON DRAWING E47 5567 03 -YD -S567 GENERAL NOTES 1. CONDUIT TO BE RIGID ALUMINUM UNLESS OTHERWISE NOTED. 2. UNLESS OTHERWISE NOTED, WIRE IS STRANDED COPPER, TYPE XHHW-2 INSULATION, MINIMUM SIZE #12 FOR POWER & #14 AWG FOR CONTROL. 0_ �0000000 C A 40QW H S LIGHTING AIRPLANE STORAGE PLANT 2 YARD 4. PERMANENTLY LABEL ALL RECEPTACLES, JUNCTION BOXES, SWITCHES, ETC., WITH PANEL AND CIRCUIT IDENTIFICATION. 5. INSTALL NEW OR REVISED PANEL SCHEDULES UPON COMPLETION OF JOB. REFERENCE DRAWINGS SEE SHT 2YD-E503 FOR LTG FIXTURE SCHEDULE. 3. THE FOLLOWING COLOR CODING OF CONDUCTORS SEE SHT 2YD-505 E10 SHALL BE OBSERVED ON ALL CIRCUITS 600 -VOLTS I E24 E23 E22 E21 OR LESS. LARGE SIZE CONDUCTORS SHALL BE A 40C�W H E18 E35 E34 IDENTIFIED WITH COLORED TAPE WHEREVER VISIBLE: 208Y 120V 480Y 277V E32 I E31 E30 E29 E28 E27 "A" 0 (LEFT BUS IN PNL) BLACK BROWN E42 E41 E40 W "B" 0 (CENTER BUS IN PNL) RED ORANGE E36 "C" 0 (RIGHT BUS IN PNL) BLUE YELLOW NEUTRAL WHITE GREY ,. EQUIPMENT GROUND GREEN GREEN 0_ �0000000 C A 40QW H S LIGHTING AIRPLANE STORAGE PLANT 2 YARD 4. PERMANENTLY LABEL ALL RECEPTACLES, JUNCTION BOXES, SWITCHES, ETC., WITH PANEL AND CIRCUIT IDENTIFICATION. 5. INSTALL NEW OR REVISED PANEL SCHEDULES UPON COMPLETION OF JOB. REFERENCE DRAWINGS CONSTRUCTION NOTES PROVIDE CONCRETE BLOCK WITH STEEL POLE. INSTALL (6) LED 30OW FLOOD LIGHTS ON THE TOP RUNGS OF EACH POLE AS INDICATED. INSTALL CONDUIT AND WIRE BETWEEN EACH POLE AND THE ASSOCIATED LIGHTING CONTACTOR, FED FROM THE MINI POWER ZONE 20 AMP, 2 POLE CIRCUIT INDICATED. NO EXPOSED GALVANIZED CONDUIT IS ALLOWED, DUE TO RESTRICTIONS ON ZINC IN STORM WATER. RECEIVED CITY OF TUKWILA NOV 2 9 2010 20 10 0 2oPERMIT46ENTER60 SCALE IN FEET SEE SHT 2YD-E503 FOR LTG FIXTURE SCHEDULE. E14 SEE SHT 2YD-505 CONSTRUCTION NOTES PROVIDE CONCRETE BLOCK WITH STEEL POLE. INSTALL (6) LED 30OW FLOOD LIGHTS ON THE TOP RUNGS OF EACH POLE AS INDICATED. INSTALL CONDUIT AND WIRE BETWEEN EACH POLE AND THE ASSOCIATED LIGHTING CONTACTOR, FED FROM THE MINI POWER ZONE 20 AMP, 2 POLE CIRCUIT INDICATED. NO EXPOSED GALVANIZED CONDUIT IS ALLOWED, DUE TO RESTRICTIONS ON ZINC IN STORM WATER. RECEIVED CITY OF TUKWILA NOV 2 9 2010 20 10 0 2oPERMIT46ENTER60 SCALE IN FEET PLANT2, WA E32 586456-02 KEY PLAN N SCALE : NONE DL ^ DATE 11/18/16 2YD-E32 =E16. E15 E14 E13 E12 E11 E10 E26 E25 I E24 E23 E22 E21 E20 E19 E18 E35 E34 E33 E32 I E31 E30 E29 E28 E27 E44 E43 E42 E41 E40 E39 E38 E37 E36 PLANT2, WA E32 586456-02 KEY PLAN N SCALE : NONE DL ^ DATE 11/18/16 2YD-E32 v w n w _ U) L LJ w 07 z CD z I= z 0 U I w z U Q _3END POLE MOUNTED - DOUBLE HEAD LUMINAIRE POLE MOUNTED - SINGLE HEAD LUMINAIRE BOLLARD UTILITY VAULT C SS LIGHTING FIXTURE IDENTIFIER LIGHT POLE MOUNTED TO 6.5'x6.5'x3.5' CONCRETE BASE, FORKLIFT PORTABLE. WITH (6) 300W, 37 DEGREE FLOODLIGHTS, E-CONOLIGHT #E-HL9S30NSZ ON THE TOP RUNGS. TILT ALL FIXTURES DOWN 10 DEGREES FROM VERTICAL. ROTATED FIXTURES ARE AT 30 DEGREES ROTATION FROM STRAIGHT AHEAD. SEE POLE DETAIL A ON DRAWING 03 -YD -S567 E47 S567 ENERAL NOTES VDUIT TO BE RIGID ALUMINUM UNLESS OTHERWISE FED. .ESS OTHERWISE NOTED, WIRE IS STRANDED 'PER, TYPE XHHW-2 INSULATION, MINIMUM SIZE ? FOR POWER & #14 AWG FOR CONTROL. FOLLOWING COLOR CODING OF CONDUCTORS %LL BE OBSERVED ON ALL CIRCUITS 600 -VOLTS LESS. LARGE SIZE CONDUCTORS SHALL BE NTIFIED WITH COLORED TAPE WHEREVER VISIBLE: 208Y 120V 480Y 277V 0 (LEFT BUS IN PNL) BLACK BROWN 0 (CENTER BUS IN PNL) RED ORANGE 0 (RIGHT BUS IN PNL) BLUE YELLOW )TRAL WHITE GREY )IPMENT GROUND GREEN GREEN ,MANENTLY LABEL ALL RECEPTACLES, JUNCTION KES, SWITCHES, ETC., WITH PANEL AND CIRCUIT NTIFICATION. TALL NEW OR REVISED PANEL SCHEDULES UPON 1IPLETION OF JOB. EFERENCE DRAWINGS :E SHT 2YD-E503 FOR LTG FIXTURE SCHEDULE :E SHT 02-127-E507 ONSTRUCTION NOTES ZOVIDE CONCRETE BLOCK WITH STEEL POLE. STALL (6) LED 30OW FLOOD LIGHTS ON THE TOP 1NGS OF EACH POLE AS INDICATED. INSTALL )NDUIT AND WIRE BETWEEN EACH POLE AND THE ;SOCIATED LIGHTING CONTACTOR, FED FROM THE NI POWER ZONE 20 AMP, 2 POLE CIRCUIT DICATED. NO EXPOSED GALVANIZED CONDUIT IS .LOWED, DUE TO RESTRICTIONS ON ZINC IN STORM %TER. SCALE IN FEET MATCH LINE - CONTINUATION SEE SHEET E42 KEY PLAN ^' SCALE : NONE IV SYM REVISION BY APPROVED DATE SYM REVISION BY APPROVED DATE 00 00 DRAWN A SUBTITLE CURRENT REVISION SYMBOL DATE o R. R O ACCEPTABILITY MJM SP 10.13.97 C 11/18/16 o'' ... ••.��,°o THIS DESIGN AND/OR H C LIGHTING - DATABASE MAPPING UPDATE - DHA ASSOC. INC 10.13.97 - AS -BUILT INCORP DP 10/31/14 O �:' oFW`�Ni ' O DAH 10.13.97 SHEET p Q'`�, N�'••.O O SPECIFICATION IS APPROVED EITUREM, TITLE 2-4X DEMO 586456-02 SAZAN/MN 04.03.09 C AIRPLANE STORAGE W4368468 KNOX 11/18/16 0) �' APPROVED BY DEPT. DATE AIRPLANE STORAGE E33 A SITE REDEVELOPMENT 586456-02 SAZAN/GBG 06.17.11 0 KED i11 : 0 CPR PLANT 2 JOB N0. COMP N0. 8 SITE REDEVELOPMENT - DCN #10 586456-02 SAZAN/GBG 03.02.12 OO ISTER`�00 586456-02 O°` �ONAt '�o°O APPROVEDi , ELECTRICAL MASTER YARD PLANT2 WA DwG No. 2YD-E33 SITE REDEVELOPMENT RECORD DRAWING 586456-02 SAZAN/GBG 02.20.13 O O a E17 E15 E14 E13 E12 E11 E10 E26 E25 qE24 E23 E22 E21 E20 E19 E18 E35 E34 E32 E31 E30 E29 E28 E27 E44 E43 E41 E40 E39 E38 E37 E36 MATCH LINE - CONTINUATION SEE SHEET E42 KEY PLAN ^' SCALE : NONE IV SYM REVISION BY APPROVED DATE SYM REVISION BY APPROVED DATE 00 00 DRAWN A SUBTITLE CURRENT REVISION SYMBOL DATE o R. R O ACCEPTABILITY MJM SP 10.13.97 C 11/18/16 o'' ... ••.��,°o THIS DESIGN AND/OR H C LIGHTING - DATABASE MAPPING UPDATE - DHA ASSOC. INC 10.13.97 - AS -BUILT INCORP DP 10/31/14 O �:' oFW`�Ni ' O DAH 10.13.97 SHEET p Q'`�, N�'••.O O SPECIFICATION IS APPROVED EITUREM, TITLE 2-4X DEMO 586456-02 SAZAN/MN 04.03.09 C AIRPLANE STORAGE W4368468 KNOX 11/18/16 0) �' APPROVED BY DEPT. DATE AIRPLANE STORAGE E33 A SITE REDEVELOPMENT 586456-02 SAZAN/GBG 06.17.11 0 KED i11 : 0 CPR PLANT 2 JOB N0. COMP N0. 8 SITE REDEVELOPMENT - DCN #10 586456-02 SAZAN/GBG 03.02.12 OO ISTER`�00 586456-02 O°` �ONAt '�o°O APPROVEDi , ELECTRICAL MASTER YARD PLANT2 WA DwG No. 2YD-E33 SITE REDEVELOPMENT RECORD DRAWING 586456-02 SAZAN/GBG 02.20.13 O O a Z' O U ZI U QI :21 SYM I REVISION A I AIRPLANE STORAGE BY W43684681 KNOX w APPROVED DATE SYM 11/18/16 REVISION MATCH LINE - CONTINUATION SEE SHEET E73 _ O ICl MATCH LINE - CONTINUATION SEE SHEET E91 BY I APPROVED I DATE E Ulm � rot,4 -1 - Z.- 0 o0 R R v��o ACCEPTABILITY ��0 THIS DESIGN AND/OR ' k.4FW�y�'� .�pp SPECIFICATION IS APPROVED i APPROVED BY I DEPT. DATE �'��S�E��o% >v0h_ TNAL moo° R-1 ELECTRICAL MASTER 111LdLLJ W IV) �z O F- nnQ Z 10 U IU �Q I cr c Kln. 30'x3/4" COPPERCLAD SECTIONAL GROUND ROD, TOP AT 30" ABOVE GROUND, WITH (4) BRASS BLOCK/COPPER BRAID ATTACHMENTS (SEE D38201-13 FIGURE 9 FOR BRASS BLOCK/COPPER BRAID ASSEMBLY). TIE TO THE 4/0 SITE GROUNDING ELECTRODE CONDUCTOR. 0 GENERAL NOTES: a CONSTRUCTION NOTES: PROVIDE GROUND ROD WITH STATIC GROUNDING ATTACHMENTS (SEE LEGEND). TIE THIS GROUND ROD TO THE OTHER GROUND RODS (ON SHEET E83), USING SURFACE -MOUNTED STRANDED BARE CU 4/0 GROUNDING ELECTRODE CONDUCTOR IN 1" SCHED 80 PVC. REVIEWED FUR COMPLIANCE WITH I NFPA 70 m NEC I 120/208V & GROUNDING PLANT2 COL. X-X/X-X DEC 0 6 2016 City of-TukWila BUILDING DIVISION 41 RECEIVED CITY OF TUKWILA NOV 2 9 2016 PERMIT CENTER 20 10 0 20 40 6 SCALE IN FEET E67 E66 E65 I E64 E63 I E62 E61 I E6 E76 E75 E74 E73 E72 E71 E70 E69 E6 E85 E84 E83 E82 E81 E80 E79 E78 E7 E94 I E93 E92 E91 E90 E89 E88 E87 E8 KEY PLAN __0 SCALE : NONE CURRENT REVISION SYMBOL DATE W4368468 A 11/18/16 PLANT 2 2.YD-E82 u GROUND TRANSFORMER I In 4/0 WITH #4 BARE CU PROTECTED BY SCHED 80 PVC PANEL MD1 GROUND BUS Q I 0 I I PANEL A, 100A, 1120/240'/, 1 PHASE I I I I I I PANEL L1, 400A, 120/208V, 3 PHASE 4/0 STRANDED BARE CU GROUNDING ELECTRODE CONDUCTOR, PROTECTED BY 1" MATCH LINE - CONTINUATION SEE SHEET E74 D GROUND STAND TO 4/0 WITH 4/0 AWG BARE CU j ER ISLAND AP1 E DETAIL 1 E83 E599 LGROUND TRANSFORMER TO 4/0 WITH #4 AWG BARE CU IN SCHED 80 PVC �l PANEL AP1-1 V) I z O� Iz z c- o o ° I �ooaooa00000000a0000a� w z � I = I I U I— Q I o ICI IN o \ 0 0 0 0 � O D O D O C� 0 0 o MATCH LINE - CONTINUATION SEE SHEET E92 LEGEND 30'x3/4" COPPERCLAD SECTIONAL GROUND ROD, TOP AT 30" ABOVE GROUND, WITH (4) D BRASS BLOCK/COPPER BRAID ATTACHMENTS (SEE D38201-13 FIGURE 9 FOR BRASS GROUND STAND TO 4/0 BLOCK/COPPER BRAID ASSEMBLY). TIE TO THE WITH 4/0 AWG BARE CU 4/0 SITE GROUNDING ELECTRODE CONDUCTOR. POWER ISLAND AP2 m TRANSFORMER SEE DETAIL1 PANELBOARD, 120/208V, 3PH OR 120/240V E83 E599 GENERAL NOTES PANEL AP2-1 G C GROUND TRANSFORMER 1. NEW CONDUIT ABOVE GRADE TO BE RIGID ALUMINUM. TO 4/0 WITH #4 AWG 2. UNLESS OTHERWISE NOTED, WIRE IS STRANDED COPPER, TYPE BARE CU IN SCHED 80 XHHW-2 INSULATION, MINUMUM #12 AWG FOR POWER & #14 AWG FOR PVC Q CONTROL E60 3. THE FOLLOWING COLOR CODING OF CONDUCTORS SHALL BE E75 c� E73 m E71 m E69 I E85 "C" PHASE RIGHT BUS IN PANEL) BLUE YELLOW E83 NEUTRAL WHITE GRAY E81 EQUIPMENT GROUND GREEN GREEN E79 ISOLATED GROUND *GRN/YEL #GRN/YEL E77 s E93 C s E91 s D° w COLORED TAPE. - i H aw H o ® H a I = rq ria ria w Ld U) w w REFERENCE DRAWINGS V) 0i lz 2-YD-MD1E4 ONE -LINE DIAGRAM V) I z O� Iz z c- o o ° I �ooaooa00000000a0000a� w z � I = I I U I— Q I o ICI IN o \ 0 0 0 0 � O D O D O C� 0 0 o MATCH LINE - CONTINUATION SEE SHEET E92 LEGEND 30'x3/4" COPPERCLAD SECTIONAL GROUND ROD, TOP AT 30" ABOVE GROUND, WITH (4) D BRASS BLOCK/COPPER BRAID ATTACHMENTS (SEE D38201-13 FIGURE 9 FOR BRASS GROUND STAND TO 4/0 BLOCK/COPPER BRAID ASSEMBLY). TIE TO THE WITH 4/0 AWG BARE CU 4/0 SITE GROUNDING ELECTRODE CONDUCTOR. POWER ISLAND AP2 m TRANSFORMER SEE DETAIL1 PANELBOARD, 120/208V, 3PH OR 120/240V E83 E599 GENERAL NOTES PANEL AP2-1 G C GROUND TRANSFORMER 1. NEW CONDUIT ABOVE GRADE TO BE RIGID ALUMINUM. TO 4/0 WITH #4 AWG 2. UNLESS OTHERWISE NOTED, WIRE IS STRANDED COPPER, TYPE BARE CU IN SCHED 80 XHHW-2 INSULATION, MINUMUM #12 AWG FOR POWER & #14 AWG FOR PVC Q CONTROL E60 3. THE FOLLOWING COLOR CODING OF CONDUCTORS SHALL BE E75 OBSERVED ON ALL CIRCUITS 600 VOLTS OR LESS E73 2081120 480127 E71 "A" PHASE LEFT BUS IN PANEL) BLACK BROWN E69 "B"PHASE CENTER BUS IN PANEL) RED ORANGE E85 "C" PHASE RIGHT BUS IN PANEL) BLUE YELLOW E83 NEUTRAL WHITE GRAY E81 EQUIPMENT GROUND GREEN GREEN E79 ISOLATED GROUND *GRN/YEL #GRN/YEL E77 (*GREEN W/ YELLOW TRACER) E93 4. LARGE SIZE CONDUCTORS WHICH DO NOT HAVE COLORED JACKETS E91 SHALL BE IDENTIFIED WHEREVER VISIBLE BY APPROPRIATELY I E89 COLORED TAPE. I E87 5. ALL UNUSED CONDUIT AND WIRE TO BE REMOVED BACK TO SOURCE, INCLUDING PLUG -ON CIRCUIT BREAKERS ON BUSWAYS. 6. PERMANENTLY LABEL ALL RECEPTACLES, JUNCTION BOXES, SWITCHES, ETC., WITH PANEL AND CIRCUIT DESIGNATION. MN W w 7. POST REVISED PANEL SCHEDULES IN ELECTRICAL PANELS UPON w COMPLETION OF JOB. w U) w w REFERENCE DRAWINGS V) lz 2-YD-MD1E4 ONE -LINE DIAGRAM 0 DEC 0 6 2016 Citi Of -Tukwila. I BUILDING DIVISION _CONSTRUCTION NOTES PROVIDE GROUND ROD WITH STATIC GROUNDING ATTACHMENTS (SEE LEGEND): ADDITIONAL GROUND ROD SHOWN ON SHEET E82. TIE I GROUND RODS TOGETHER, AND TO GROUND Ll BUS OF PANEL MD1, USING SURFACE -MOUNTED STRANDED BARE CU 4/0 GROUNDING ELECTRODE CONDUCTOR IN 1" SCHED 80 PVC. t � GROUND METAL FRAME OF POWER ISLAND '- STAND, AND GROUND THE MINI POWER ZONE SECONDARY NEUTRAL, TO THE 4/0 GROUNDING ELECTRODE CONDUCTOR AS INDICATED. PROVIDE CONDUIT AND WIRE BETWEEN TRANSFORMER AND EXISTING CREW SHELTER 100A, 120/240V PANEL A. SEE ONE -LINE DIAGRAM 2-YD-MD1 E4 FOR SIZING. 20 10 0 20 40 60 SCALE IN FEET KEYPLAN N SCALE : NONE RECEIVED CITY OF TUKWILA NOV 2 9 2016 PERMIT CENTER SYM REVISION BY APPROVED DATE SYM REVISION BY APPROVED DATE pv� "Up DRAWN DATE SU8T17LE CURRENT REVISION SYMBOL DATE O R R. O ACCEPTABILITY � 120/208 & GROUNDING W4368468 A 11/18/16 A AIRPLANE STORAGE W4368468 KNOC 11/18/16 0°�oFWgsNi� ?�� Oo SP CHFlCATtoN NS APPROVED H SHEET ® 3 E83 APPROVED BY DEPT. DATE CHECKED PROV D PLANT 2 JOB N0. O F���(ic�,.•� � COMP N0. Op;'•••....... �, °� 000��pNAL Popo APPROVED ELECTRICAL MASTER COL. X-X/X-X PLANT 2, WA DWG N0. 2.YD-E83 E67 I E66 E65 E64 E63 E62 E61 E60 E76 E75 E74 E73 E72 E71 E70 E69 E68 E85 E84 E83 E82 E81 E80 E79 E78 E77 E94 E93 E92 E91 I E90 I E89 I E88 I E87 I E86 KEYPLAN N SCALE : NONE RECEIVED CITY OF TUKWILA NOV 2 9 2016 PERMIT CENTER SYM REVISION BY APPROVED DATE SYM REVISION BY APPROVED DATE pv� "Up DRAWN DATE SU8T17LE CURRENT REVISION SYMBOL DATE O R R. O ACCEPTABILITY � 120/208 & GROUNDING W4368468 A 11/18/16 A AIRPLANE STORAGE W4368468 KNOC 11/18/16 0°�oFWgsNi� ?�� Oo SP CHFlCATtoN NS APPROVED H SHEET ® 3 E83 APPROVED BY DEPT. DATE CHECKED PROV D PLANT 2 JOB N0. O F���(ic�,.•� � COMP N0. Op;'•••....... �, °� 000��pNAL Popo APPROVED ELECTRICAL MASTER COL. X-X/X-X PLANT 2, WA DWG N0. 2.YD-E83 e TO VAULT 21 VIA H -E & Fes! 4"C.3#500 KCMIL PC1-VAULT G13 504PL, 600A 15KV, 100A FUSED SW (VI13) VAULT H13 504PL, 600A 15KV } (SUMMIT 1500 KVA, 480/277V) 12 PNL. H3, 400A, 480/277V, � 3 PHASE / MATCH LINE - CONTINUATION SEE SHEET E124 —PANEL L1, 400A, 120/208V, POWER ISLAND AP1 25 KVA 83 PHASE SEE DETAIL 1 480:120/240V ' D CONNECT Ot�A FUSED � E133 E599 IH S, 480/208/12OV, 75 x CREW N A XFMR PANEL AP1 - SHELTER MD1, EATON, MAIN SERVICE, 1600A, 480 277V, 3 PHASE (2) 3" RAC (SURFACE MOUNT), 3#350 KCMIL, #1G TO PANEL MD1, II 600A CIRCUIT BREAKER #1 (PROVIDE AS -BUILT CIRCUIT NUMBER) SPARE 1 I G rp z ro I ro i 0 PERMIT CENTER I I nl P L A3-1 M C0 1 1 -1 20 -1 0 20 40 60 x =P `I A3 2-3"C(ABAND) r_j r_j cj � IK s s SCALE IN FEET ,—{ x H H 0 1 2"C,3-1 "C(ABAND) ED 0 E117 El E115 _ E113 p E111 PQ PCI POWER ISLAP SEE DETAIL E '- PANEL AP2 (2) 3" RAC (SURFACE MOUNT), 3#350 KCMIL, #1G TO PANEL MD1, 600A CIRCUIT BREAKER #2 (PROVIDE AS -BUILT CIRCUIT NUMBER) NO LEGEND m TRANSFORMER ® PANELBOARD, 480V GENERAL NOTES 1. NEW CONDUIT ABOVE GRADE TO BE RIGID ALUMINUM. 2. UNLESS OTHERWISE NOTED, WIRE IS STRANDED COPPER, TYPE XHHW-2 INSULATION, MINUMUM #12 AWG FOR POWER & #14 AWG FOR I CONTROL 3. THE FOLLOWING COLOR CODING OF CONDUCTORS SHALL BE OBSERVED ON ALL CIRCUITS 600 VOLTS OR LESS 208/120V 480 277V W PHASE LEFT BUS IN PANEL) BLACK BROWN "B" PHASE CENTER BUS IN PANEL) RED ORANGE "C" PHASE RIGHT BUS IN PANEL) BLUE YELLOW NEUTRAL WHITE GRAY EQUIPMENT GROUND GREEN GREEN ISOLATED GROUND #GRN/YEL #GRN/YEL (*GREEN W/ YELLOW TRACER) 4. LARGE SIZE CONDUCTORS WHICH DO NOT HAVE COLORED JACKETS SHALL BE IDENTIFIED WHEREVER VISIBLE BY APPROPRIATELY COLORED TAPE. 5. ALL UNUSED CONDUIT AND WIRE TO BE REMOVED BACK TO SOURCE, INCLUDING PLUG -ON CIRCUIT BREAKERS ON BUSWAYS. M 6. PERMANENTLY LABEL ALL RECEPTACLES, JUNCTION BOXES, Lu SWITCHES, ETC., WITH PANEL AND CIRCUIT DESIGNATION. t;_j 7. POST REVISED PANEL SCHEDULES IN ELECTRICAL PANELS UPON s COMPLETION OF JOB. d d b' _ I �ooaooa000000aooa0000 z J ® (4) 4" SPARE (1) 1 1/4" LTG. SEE SHEET 2YD-1E8 x HH -8 F 1 331 E504 UTILITY VAULT 444 -LA 1 E133 E503.1 F NJ i 1/2"C (ABANDONED) REFERENCE DRAWINGS 1� 02-127-1 E6 02-127-1E110 02-127-E507 ® 2YD-E504 2YD-E213A, E215A, FOR CMCS WIRING TO ACTUATORS CONSTRUCTION NOTES D AT PANEL MD1, REMOVE (1) 600A AND (2) 200A CIRCUIT BREAKERS, AND REPLACE WITH BLANK PANELS. IN PANEL H3, INSTALL A 70A, 2 POLE CIRCUIT BREAKER, FOR FEEDING CREW SHELTER. PROVIDE NEMA 3R TRANSFORMER FOR CREW SHELTER POWER. CONNECT IT TO 70A BREAKER IN PANEL h3. PROVIDE POWER TO 480V PANEL AT POWER ISLAND. 5. CREATE AS -BUILT PANEL SCHEDULES FOR -ALL PANELBOARDS- IN THIS PROJECT (MD1, L1, A, H3, AP1, AP1-1, AP2, AP2-1) IN STANDARD BOEING EXCEL FORMAT (BLANK FURNISHED ON REQUEST). &r RECEIVED CITY OF TUKWILA G TLC "LCP A3-1" z x 0 PERMIT CENTER I nl P L A3-1 1 o 20 10 0 20 40 60 =P `I A3 2-3"C(ABAND) d d b' _ I �ooaooa000000aooa0000 z J ® (4) 4" SPARE (1) 1 1/4" LTG. SEE SHEET 2YD-1E8 x HH -8 F 1 331 E504 UTILITY VAULT 444 -LA 1 E133 E503.1 F NJ i 1/2"C (ABANDONED) REFERENCE DRAWINGS 1� 02-127-1 E6 02-127-1E110 02-127-E507 ® 2YD-E504 2YD-E213A, E215A, FOR CMCS WIRING TO ACTUATORS CONSTRUCTION NOTES D AT PANEL MD1, REMOVE (1) 600A AND (2) 200A CIRCUIT BREAKERS, AND REPLACE WITH BLANK PANELS. IN PANEL H3, INSTALL A 70A, 2 POLE CIRCUIT BREAKER, FOR FEEDING CREW SHELTER. PROVIDE NEMA 3R TRANSFORMER FOR CREW SHELTER POWER. CONNECT IT TO 70A BREAKER IN PANEL h3. PROVIDE POWER TO 480V PANEL AT POWER ISLAND. 5. CREATE AS -BUILT PANEL SCHEDULES FOR -ALL PANELBOARDS- IN THIS PROJECT (MD1, L1, A, H3, AP1, AP1-1, AP2, AP2-1) IN STANDARD BOEING EXCEL FORMAT (BLANK FURNISHED ON REQUEST). &r RECEIVED CITY OF TUKWILA SYM REVISION BY APPROVED DATE SYM REVISION BY APPROVED DATE O"� 0 ��� Wolll" I.VRRG171 IRCv1Qjv1`I ...... oo��R.... 'too ACCEPTABILITY �.oMAUEY o1.1ss7 480V, MED. VOLTAGE W436846s O O THIS DESIGN AND/OR CHECKED - DRAWING UPDATE FSI 10.11.98 - SITE REDEVELOPMENT - RECORD DRAWING 586456-02 SAZAN/GBG 02.20.13 O ' oFW'' •� O O SPECIFICATION IS APPROVED ENGINEER SHEET A DECOMMISSION BUILDING 2-65 710658-00 BOYE 04.26.01 - AS -BUILT INCORP NO RM 11.11.14'docam : APPROVED BY DEPT. DATE TITtE AIRPLANE STORAGE El 3 B DECOMMISSION BUILDING 2-63 710661-00 BOYE 08.23.01 D AIRPLANE STORAGE W4368468 KNOX 11/18/16 1t�Z2 g c' CHECKED - 2-0 DEMO 586456-02 sAZAN/MN 04.03.09 °O ?'��,�:' 00 APPROVED PLANT 2 JOB No. 710661-00 C SITE REDEVELOPMENT 586456-02 SAZAN/GBG 06.17.11 O°o�Ss/.�0000 APPROVED QRiFI ELECTRICAL MASTER YARD PLANT2, WArl No. 2YD-E133 11/18/16 C G TLC "LCP A3-1" PERMIT CENTER nl P L A3-1 20 10 0 20 40 60 =P `I A3 2-3"C(ABAND) � SCALE IN FEET x REVIEWED ruR 1 2"C,3-1 "C(ABAND) COMPLIANCE WITH ' E117 E116 E115 E114 E113 E112 E111 E110 i N aFRA7®©E E126 E125 E124 E123 E122 E121 E120 E119 E118 0 0 0 o x DEC Q 6 2016 I E135 E134 E133 E132 E131 E130 E129 E128 E127 OUTDOOR LTG Is x a a CONTRACTOR o o �X E144 E143 E142 E141 E140 E139 E138 E137 E136 PNL "OLCP" COMM. VAULT< o City of-Tukrlla I KEY PLAN AwwnI _ _o _ N MATCH LINE - CONTINUATION SEE SHEET E142 SCALE :NONE SYM REVISION BY APPROVED DATE SYM REVISION BY APPROVED DATE O"� 0 ��� Wolll" I.VRRG171 IRCv1Qjv1`I ...... oo��R.... 'too ACCEPTABILITY �.oMAUEY o1.1ss7 480V, MED. VOLTAGE W436846s O O THIS DESIGN AND/OR CHECKED - DRAWING UPDATE FSI 10.11.98 - SITE REDEVELOPMENT - RECORD DRAWING 586456-02 SAZAN/GBG 02.20.13 O ' oFW'' •� O O SPECIFICATION IS APPROVED ENGINEER SHEET A DECOMMISSION BUILDING 2-65 710658-00 BOYE 04.26.01 - AS -BUILT INCORP NO RM 11.11.14'docam : APPROVED BY DEPT. DATE TITtE AIRPLANE STORAGE El 3 B DECOMMISSION BUILDING 2-63 710661-00 BOYE 08.23.01 D AIRPLANE STORAGE W4368468 KNOX 11/18/16 1t�Z2 g c' CHECKED - 2-0 DEMO 586456-02 sAZAN/MN 04.03.09 °O ?'��,�:' 00 APPROVED PLANT 2 JOB No. 710661-00 C SITE REDEVELOPMENT 586456-02 SAZAN/GBG 06.17.11 O°o�Ss/.�0000 APPROVED QRiFI ELECTRICAL MASTER YARD PLANT2, WArl No. 2YD-E133 11/18/16 C (E) (E) (E) 3/4" C TO MPZ (N) SYM JILL V L I /-11 L( G l FOR STAND E599 EAST ELEVATION 1 "CTO WIREWAY ON OPPOSITE (N) IE� POWER ISLAND DETAIL SCALE: 3/8"=1'-0" E33,E83,E133 E599 REVISION BY I APPROVED 1" C TO 480V PANEL ONn1OPPOSITE SIDE APPLIES TO POWER ISLANDS AP1 & AP2 DATE I SYM L u 1 V It V PANEL ON OPPOSITE SIDE (N) RETU @ C( lal D ETAI L SCALE: 3/8"=1'-0" E599 P'11 A / A A P1 f !•1 )% SECTION rB_'� SCALE: 1-1/4"=1'-0" E599 3" EA END 'L ONLY )TH SIDES O Q (:3) (4) (5) (6) O (:8) (9) 10 11 GENERAL NOTES: ANY NEW CONDUIT SHALL BE RIGID ALUMINUM. IF FLEXIBILITY IS REQUIRED, THEN LIQUIDTIGHT FLEXIBLE METAL CONDUIT MAY BE USED. ANY NEW WIRE SHALL BE TYPE XHHW-2. MEGGER TEST ALL NEW AND EXISTING WIRING. WIRE AND CONDUIT SIZES SHALL COMPLY WITH THE NATIONAL ELECTRICAL CODE. WHERE EXISTING NAMEPLATES ARE NOT CORRECT, PROVIDE NEW PHENOLIC NAMEPLATES (WHITE LETTERS ON BLACK) FOR ALL POWER ISLAND EQUIPMENT. NAMEPLATE SHALL INCLUDE THE POWER SOURCE PANEL/CIRCUIT IDENTIFICATION. CREATE AND POST AS -BUILT PANEL SCHEDULES FOR THE 480V PANELS AND THE MINI POWER ZONES, USING A BOEING STANDARD EXCEL FILE FORMAT. PROVIDE EXCEL FILES AND AS -BUILT DRAWINGS TO BOEING. (E) = EXISTING (N) = NEW (M) = MODIFIED EQUIPMENT NOTES: NEMA 5-20R GFCI DUPLEX RECEPTACLE WITH WEATHERPROOF -WHILE -IN -USE CAST ALUMINUM DEEP COVER (INTERMATIC WP1250MVXD). EACH DUPLEX ON AN INDIVIDUAL CIRCUIT. 30A, 600VAC, 3W, 4 POLE RECPT. (CROUSE HINDS #ARE3422) WITH FUSED 30A DISCONNECT SWITCH (NEMA 4X -STAINLESS STEEL) WITH CLASS RK1 OR RK5 FUSES. 60A, 60OV, 3W, 4 POLE RECEPT. (CROUSE -HINDS ARE6424) WITH FUSED 60A DISCONNECT SWITCH. (NEMA 3R OR 4X -STAINLESS STEEL) WITH CLASS RK1 OR RK5 FUSES. 225A, 3 POLE 480V NON -AUTOMATIC CIRCUIT BREAKER (25 KA WITHSTAND RATING) WITH NEMA 3R OR 4X -STAINLESS STEEL ENCLOSURE. 200A, 60OVAC, 3W, 4 POLE RECEPT. CROUSE HINDS #AREA20426. 72" 8 X 8 NEMA 4X STAINLESS STEEL WIRING TROUGH WITH HINGED COVER. 8"x8"x6' WIRING TROUGH WITH HINGED COVER, NEMA 4X STAINLESS STEEL. 20OW, 120V PANEL HEATER WITH THERMOSTAT HOFFMAN #A-DAH2001 FT. SET THERMOSTAT TO 60 DEGREES F. 20A, 120V, TWO GANG EXPLOSION PROOF RECEPTACLES, #CPS152-202SA. EACH RECEPTACLE TO BE ON AN INDIVIDUAL CIRCUIT. PROVIDE GFCI BREAKERS IN THE MINI POWER ZONE FOR THESE CIRCUITS. NEMA 3R 6 -POLE LIGHTING CONTACTOR, FOR (3) 120/24OV, 20A LIGHTING CIRCUITS, WITH HAND -OFF -AUTO SWITCH AND 120V CONTROL, WITH PHOTOCELL FOR AUTOMATIC .CONTROL. PROVIDE PHOTOCELL CONTROL WHEN IN AUTO SWITCH POSITION, AND MANUAL ON WHEN IN HAND POSITION. TWO EXISTING STANDS ARE RELOCATED FROM NORTH BOEING FIELD. SQUARE -D MINI POWER ZONE (COMBINATION 480V BREAKER, TRANSFORMER, AND 120/240V PANELBOARD). 25 KVA RATING, PRIMARY 480V, SECONDARY 120/240V SINGLE PHASE. PROVIDE ANY ADDITIONAL CIRCUIT BREAKERS THAT MIGHT BE NEEDED FOR NEW LOADS. NEW PANEL NAMES WILL BE "API -1" AT POWER ISLAND AP1 OR "AP2-1" AT POWER ISLAND AP2. FOR THE POWER FEED FROM PANEL AP1 TO PANEL AP1-1, ADD AN EXTRA RUN BACK AND FORTH IN THE WIREWAY, TO ADD AN EXTRA 12' OF #4 CONDUCTOR (TOTAL CIRCUIT LENGTH ABOUT 18'). THIS WILL INSURE THAT THE 18 KA RATING OF THE 480V BREAKER IN THE MINI POWER ZONE IS NOT EXCEEDED. GROUND THE TRANSFORMER SECONDARY TO THE COMMON 4/0 GROUNDING ELECTRODE CONDUCTOR. 480V PANEL "AP1" AT POWER ISLAND AP1 (CLOSEST TO PANEL MD1) OR 12-"AP2" AT POWER ISLAND AP2. EACH PANEL WILL BE SERVED BY (2) 3" CONDUITS WITH 350 KCMIL CONDUCTORS. PROVIDE RAINTIGHT HOLE COVERS FOR ALL UNUSED HOLES IF EXISTING PANEL ENCLOSURE IS REUSED. 2x`1411-2)) FOR EXISTING PANELBOARD WITH 800A MAIN LUG INTERIOR: RELOCATE CIRCUIT BREAKERS AS NECESSARY TO ENSURE THAT NO CIRCUIT BREAKER OPERATING HANDLES WILL BE ABOVE 6'-7" FROM THE GROUND LEVEL. ADD ADDITIONAL BREAKERS AS NECESSARY FOR NEW LOADS. FOR EXISTING PANELBOARD WITH 400A MAIN LUG INTERIOR: EITHER REPLACE PANEL INTERIOR WITH 800A MAIN LUG INTERIOR (SAME AS EXISTING 800A REVIEwi=,- j,-6,PANEL), OR PROVIDE NEW PANELBOARD WITH THE SAME TYPE OF COMPLIANDE I'll ENCLOSURE. EXISTING CIRCUIT BREAKERS ARE PERMITTED TO BE REUSED. NFPA 70 - flEC LOCATE CIRCUIT BREAKERS TO ENSURE THAT NO CIRCUIT BREAKER OPERATING HANDLES ARE ABOVE 6'-7" FROM THE GROUND LEVEL. ADD ADDITIONAL BREAKERS AS NECESSARY FOR NEW LOADS. INTERRUPTING EIEC O 6 2016 RATING 25KA. RECEIVED ! CITY OF TUKWILA City oiTult�ril�. _ NUV 2 9 2016 BUIL®Ii�G Dl v iSICCv fAm% a- DRAWN DATESUBTITLE REVISION BY APPROVED DATE Q� R R oo ACCEPTABILITY W. KNOX 10 13/16 IS DESIGDOR CHECKED PLANT 2 AIRPLANE STORAGE SPECIFICATION rISAAPPROVED M. KNOPP 10/13/16 POWER ISLAND DETAIL Q �0 TITLE : Q APPROVED BY DEPT. DATE �l CHECKED APPROVED PLANT 2 YARD OVAL � o o'f, 0 0o APPROVED ELECTRICAL MASTER CURRENT PERMIT CENTER RIO' 11/18/16 E599 JOB NO. COMP NO. W4558717 PLANT 2, WA DWG NO. 02 -YD -E599 --------------- I I x3/16 I z I00� w K3/16 n 1 1/2" CHAMFER - 5S5667 z 1/2 x o U 00 rD S567 OF SLAB l ) 1 PORTABLE LIGHT POST S567 SECTION A SCALE: 1/4"=1'-0" E36, E45, E46, E47 S567 SEAL WELD 3/16 2"0 HOLE -GRIND SMOOTH AND RADIUS CORNERS SECTION SCALE: 1 "=1'-0 DETAIL SCALE: 1"=l'—O" SYM REVISION A AIRPLANE STALL EXPANSION - IFP B AIRPLANE STALL EXPANSION - IFP C AIRPLANE STALL EXPANSION - IFC PL1/8 CAP PLATE WITH 4"0 HAND HOLE AND 5"0 REMOVABLE CAP PLATE. SEE FOR REMOVABLE A SIM CAP U�> S567 S568 2"0 SCHEDULE 40 PIPE TYP 2"0 HOLE -GRIND SMOOTH AND RADIUS (TYP AT 2"0 PIPE) L HAND HOLE W/ 4"0 OVABLE CAP PLATE AT -H 22"0 PIPE, SEE A S567 S568 HSS4 tB S567 PL1/2 SPLICE PLATE (TYPICAL) SEE 7 S567 5S567 GENERAL NOTES BY APPROVED DATE SYM W3689354 HG NEM 06.21.16 RED AND WHITE BANDS, 5'-0" WIDTH, RED ON TOP. W3689354 HG NEM 08.31.16 LL _/ W36893541 HG NEM 1 10.05.16 B GENERAL NOTES MOVABLE LIGHT POLE FOUNDATION B PRIME AND PAINT ALL STEEL LIGHT BRACKETS TO BE FEDERAL B S. DUFFY ANCHOR ASSEMBLY ,� 2'-6 3/4" X11. 4 1/2"I� 2'-6 3/4" #4 VERTICAL 1 r 6n 1 i_6n (10) PLACES 1 1/2" CHAMFER TYP #4 BARS `� #4 VERTICAL B �- (3#4 TIES 14 #4 12 12 BUILDING PAPE SEPARATION AT SLAB B HSS14x6x3/8 FORK POCKETS. 0 cV n I I I I 3 "�II�I" B "' I I I I (4) #4 BARS (-1 I I TYPICAL ® 3 LEVELS EA. WAY 1 1 to ` of ANCHOR ASSEMBLY I I ° ° I 1 SEE � I l I I S567 I I I N o ► I n I I o �4 TIES I - 2"0 SCHEDULE 40 PIPE r LJ L- I !-1 I I_ p 1 SCALE: 1"=l'—O" S567 REVISION BY APPROVED DATE PL1/8 LAP (SEAL WELD) TYPICAL b SCHEDULE PIPE Z) PLACES PL1/8 CAP (SEAL WELD) TYPICAL BASE PLATE D ETAI L SCALE: 3"=l'—O" S567 D M r r r DETAIL SCALE: 1 "=1'-0 PL1 1/8x18x1'-6" BASE PLATE B 1/4 1/4 J/ /4 PROVIDE WELD AT TOP OF PL 1/4 _ 3/8 TO SEAL 5/16 1 1/2"0 DRAIN HOLE PROVIDE WIRE BIRD AND RODENT SCREEN FASTEN W/ (4) SCREWS, SEE FOR SCREW SIM INFORMATION S567 S568 (8) �1/ HOLESFORS' (8) 1 1/8-0 F1554 GRADE 55 ANCHOR RODS HSS7 POST Pk (4) 13/16"0 HOLES FOR (4) 3/4"0 A325 BOLTS PL1/2 SPLICE PLATE 4"0 HOLE (GRIND SMOOTH) D LEGEND F1554 ICHOR B GENERAL NOTES 1. PRIME AND PAINT ALL STEEL LIGHT BRACKETS TO BE FEDERAL THIS DESIGN AND/OR SPECIFICATION IS APPROVED S. DUFFY STANDARD SAFETY COLORS WHITE, POLES TO BE ALTERNATING PL3/8x18x1'-6" RED AND WHITE BANDS, 5'-0" WIDTH, RED ON TOP. APPROVED BY SEE 09 90 00. DATE LL _/ PROVIDE FORK POCKETS: HSS14x6x3/8x6'-6" LONG. TITLE AIRPLANE STALL EXPANSION NORTH BOEING FIELD ISTRUCTURAL MASTER NORTH BOEING FIELD l PROVIDE 1/4" CLOSED CELL SILICONE SPONGE BY BELLO FOAM OR APPROVED EQUAL ADHERED TO COVER PLATES. MANUFACTURER S" DUCECKEFFY TO PROVIDE PRESSURE SENSITIVE ADHESIVE. (8) 1 1/4-0 HOLES FOR (8) 1 1/8"0 ® INSTALL POLE PLUMB. RE -ADJUST TO PLUMB AS NECESSARY ANCHOR RODS 06.21.16 AFTER EACH RELOCATION. 5. SEE ELECTRICAL DRAWINGS FOR LOCATION AND ELECTRICAL CONNECTIONS. 3 6. FOR GROUNDING SEE ELECTRICAL DRAWINGS E86, E96, E97, AND 8 S567 E> MOVABLE LIGHT POLE FOUNDATION DESIGN LOADS: ULTIMATE DESIGN WIND SPEED Vult = 110 PMH, EXPOSURE C. OVERTURNING MOMENT AT TOP OF MOVABLE FOUNDATION = 51.0 FT* KIPS (LRFD) B J DESIGN BASED ON (12) KIM LIGHTNING ALT 240 LUMINARIES. , J REFERENCE DRAWINGS 03-YD-S2F STRUCTURAL GENERAL NOTES CONSTRUCTION NOTES RECEIVED CITY OF TUKWILA NOV 2 9 2016 REVIEW -EL_ PERMIT CENTER OMPLIANC NFPA70--€IFFY Dru 0 6 ?w FINAL APPROVAL PENDING City of Tuk�ril: KING COUNTY REVIEW UIL®ING ®IVl .. WBS 2.0&2.1 - B & C LINE ISSUED FOR PL3/8 CONSTRUCTION Our difference DETAIL D ETA I L8 I is engineered. www.harrisgroup.com SCALE: 3"=1'-0" S567 SCALE. 3"=l'—O" S567 op PROJECT NO: 12592.00 G)�waF wAsDRAWN �lrj. ACCEPTABILITY S. SAMSON D04.22.16 SUBTITLE CURRENT REVISION SYMBOL DATE CHECKED LIGHT POLE SECTIONS AND DETAILS W3689354 C 10.05.16 5567 W3689354 COMP N0. 03—YD—S567 c t A�O��L2�,����' SSIONAL� 09/28/16 4: 4 PM THIS DESIGN AND/OR SPECIFICATION IS APPROVED S. DUFFY 06.21.16 APPROVED BY DEPT. DATE ENGINEER A. WARNER 06.21.16 TITLE AIRPLANE STALL EXPANSION NORTH BOEING FIELD ISTRUCTURAL MASTER NORTH BOEING FIELD S" DUCECKEFFY 06.21.16 APPROVED D. KYLE 06.21.16 NPMANDELENAKIS 1 06.21.16 5567 W3689354 COMP N0. 03—YD—S567 DETAIL SCALE: 3"=1'-0 DRILL AND TAP (4) HOLES FOR #10-24 HEX SCREW, TYPE 316 STAINLESS STEEL PL1/8x5"x0'-7" COVER PLATE 4"x0'-6" VERTICAL HAND HOLE (OBLONG SHAPE) S5671S568 PL1/8x4"0 CAP PLATE a> 3" HAND I ,2) HOLES FOR :AD SCREW -ESS STEEL SECTION a SCALE: 3"=1'-0" S567 S568 GENERAL NOTES 1. PRIME AND PAINT ALL STEEL LIGHT BRACKETS TO BE WHITE, POLES TO BE ALTERNATING RED AND WHITE BANDS, 5'-0" WIDTH, RED ON TOP. 2� PROVIDE 1/4" CLOSED CELL SILICONE SPONGE BY BELLO FOAM OR APPROVED EQUAL ADHERED TO COVER PLATES. MANUFACTURER TO PROVIDE PRESSURE SENSITIVE ADHESIVE. REFERENCE DRAWINGS 03-YD-S2F STRUCTURAL GENERAL NOTES REVIEWED OMPLIANCE WITH NFPA 70 c NFC, t DEC 0 6 2016 i City of.TuWila ..yt 3UILDING DIVISI0t°r° RECEIVED CITY OF TUKWILA NOV 2 9 2016 PERMIT CENTER FINAL APPROVAL PENDING KING COUNTY REVIEW WBS 2.0&2.1 - B & C LINE ISSUED FOR CONSTRUCTION I Our difference is engineered. ' www.harrisgroup.com PROJECT NO: 12592.00 SAS f ACCEPTABILITY DRAWN ON DD7.27.16 SUBTITLE ��++ //�� �+ /'+ �+ pp �+ CURRENT REVISION SYMBOL R DATE SYM REVISION BY APPROVED DATE SYM REVISION BY APPROVED DATE ���oF �' ���' THIS DESIGN AND/OR CHECKED LIGHT PULE SECTIONS AND DETAILS W3689354 LJ 10'05'16 A AIRPLANE STALL EXPANSION IFP W3689354 HIS NEM 08.31.16 02 SPECIFICATION IS APPROVED A. WARNER 08.31.18 SHEET ENGINEER B AIRPLANE STALL EXPANSION - IFC W3689354 HG TITLE AIRPLANE STALL EXPANSION NEM 10.05.16 APPROVED BY DEPT. DATE A. WARNER 08.31.16�CHECKEDS. S568�o��'SS+ L2 � �� 08.31.16 NORTH BOEING FIELD JOB NO. COMP NO. A ROVED ONAL W3689354 09i28i16 4: 4 Piv1 N MANDELENAKIS 08.31.16 STRUCTURAL MASTER NORTH BOEING FIELD °wc No. 03—YD—S568