Permit EL16-1161 - ZAYO - BREAKERS, DISCONNECTS, METERS ETC
ZAYO 3311 S 120 PL ELl 6=1 161 City of Tukwila • Department of Community Development • 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Inspection Request Line: 206-438-9350 Web site: http://www.TukwilaWA.Rov ELECTRICAL PERMIT Parcel No: 1023049078 Permit Number: EL16-1161 Address: 3311 S 120TH PL 120TH Issue Date: 12/23/2016 Permit Expires On: 6/21/2017 Project Name: ZAYO Owner: Name: SABEY CORPORATION Address: 12201 TUKWILA INTL BLVD 4TH FL, SEATTLE, WA, 98168 Contact Person: Name: JASON PECOTTE Phone: (206) 633-2811 Address: 12828 NORTHUP WY, STE 205, BELLEVUE, WA, 98005 Contractor: Name: TITAN ELECTRIC INC Phone: (206) 633-2811 Address: 12828 NORTHUP WAY, SUITE 205, BELLEVUE, WA, 98005 License No: TITANE19630B Expiration Date: 9/2/2018 Lender: Name: Address: DESCRIPTION OF WORK: PROVIDE AND INSTALL (2) 700 AMP BREAKERS, (2) 800 AMP NEMA 3 DISCONNECTS, (2) VERIS METERS FOR WASHINGTON STATE ENERGY CODE. CUT IN (3) OWNER PROVIDED VFD'S FOR PUMPS. PROVIDE WIRING AND CONDUIT FOR (1) PUMP. REWORK WIRING FOR (2) EXISTING PUMPS. PROVIDE AND INSTALL 4/0 GROUND FOR EACH CHILLER BACK TO MAIN GROUND BAR. PROVIDE (2) 800 AMP FEEDS OUT TO CHILLER YARD FOR HOOKUP (2) NEW 300 TON TRANE CHILLERS. PROVIDE AND INSTALL MAINTENANCE OUTLETS. TITAN JOB #169077 Valuation of single family: $0.00 Fees Collected: $2,849.28 Valuation of mf/comm: $143,802.00 Type of Work: TENANT IMP Electrical Service Provided by: SEATTLE CITY LIGHT Water District: 125,TUKWILA Sewer District: VALLEY VIEW Current Codes adopted by the City of Tukwila: International Building Code Edition: 2015 National Electrical Code: 2014 International Residential Code Edition: 2015 WA Cities Electrical Code: 2014 International Mechanical Code Edition: 2015 WAC 296-46B: 2014 Uniform Plumbing Code Edition: 2015 WA State Energy Code: 2015 International Fuel Gas Code: 2015 Permit Center Authorized Signature: Yjt' Date: Ir��3�• X� I hearby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating consytuFtign or the performance of work. I am authorized to sign and obtain this development permit a)r d` ree onditions attached to this permit. Signature: Date: 11Z -73 l ,L Print Name: Z_ d This permit shall become null and void if the work is not commenced within 180 days for the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. PERMIT CONDITIONS: 1: 'ELECTRICAL PERMIT CONDITIONS' 2: A copy of the electrical work permit shall be posted or otherwise made readily accessible to the Electrical Inspector at each work site. 3: Approved plans shall be maintained at the construction site and shall be readily available to the Electrical Inspector. 4: All electrical work shall be in accordance with NFPA 70 - NEC, and requirements for electrical installations, Chapter 296-46B WAC. S: When any portion of the electrical installation is to be hidden from view by permanent placement of parts of the building, such equipment shall not be concealed until it has been inspected and approved by the Electrical Inspector. 6: The issuance of an electrical work permit shall not be construed to be a permit for, or an approval of, any violation of the provisions of the electrical code or other ordinances of the jurisdiction. Permits or related documentation that presumes to grant this authority are therefore not valid. 7: Any change in the scope of work described by the electrical work permit shall require additional work permits. Where approved plans have been issued, revisions to the plans and additional review may be required. PERMIT INSPECTIONS REQUIRED Permit Inspection Line: (206) 438-9350 2100 ELECTRICAL FINAL 7003 ROUGH -IN ELECTRICAL 7002 SERVICE 7001 UNDERGROUND/SLAB CITY OF TUKW1. .r Community Development Department Permit Center • 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://www.Tukwi]aWA.gov SITE LOCATION Electrical Permit No. Project No. Date Application Accepted: ` Date Application Expires: 4 1 or office use only) ELECTRICAL PERNHT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. "Please Print" King Co Assessor's Tax No.: Site Address: 3311 South 120th Place Suite Number. 120 Floor: Tenant Name: Zayo New Tenant: ❑ .....Yes ®..No PROPERTY OWNER Name: Zayo Address: it, City: State: Zip: CONTACT PERSON — person receiving all project communication Name: Jason Pecotte Address: 12828 Northup Way Suite 205 City: Bellevue State: WA Zip: 98005 Phone: (206) 633-2811 Fax: (206) 374-2128 Email: Valuation of Project (contractor's bid price): $ 143,802 ELECTRICAL CONTRACTOR INFORMATION Company Name: Titan Electric, Inc. Address: 12828 Northup Way Suite 205 City: Bellevue State: WA Zip: 98005 Phone: (206) 633-2811 Fax: (206) 374-2128 Contr Reg No.: TitanEI19630B Exp Date: 09/02/2016 Tukwila Business License No.; BUS -0992893 Scope of Work (please provide detailed information): Provide and install (2) 700A Breakers. (2) 800 A NEMA 3 disconnects. (2) Veris Meters for WA State Energy Code. Cut in (3) Owner Provider VFD's for pumps. Provide Wiring and conduit for (1) Pump. Rework Wiring for (2) existing pumps. Provide and install 4/0 grout for each chiller back to main ground bar. Provide (2) 800A feeds out to chiller yard for hookup (2) new 300T es Type of Use: Commercial Type of work: ��' • l 1'Tri) Adding more TT• Yes ❑ No ❑ New m Addition ❑ Service Change ❑ Remodel m Tenant Improvement ❑ Low Voltage ❑ Generator ❑ Fire Alarm ❑ Telecommunication ❑ Temporary Service Property Served by: ❑ Puget Sound Energy Seattle City Light H:Wpplications\Forms-Applications On Line\2014 Applications\Electrical Permit Application Revised 1-1-14.do" Revised: January 2014 bh Page I of 2 RESIDENTIAL NEW RESIDENTIAL SERVICE ❑ New single family dwellings ................................... $152.85 (including an attached garage) ❑ Garages, pools, spas and outbuildings ........................$81.90 ea ❑ Low voltage systems (alarm, furnace thermostat) ................................ $59.85 ea RESIDENTIAL REMODEL AND SERVICE CHANGES ❑ Service change or alteration ...................................... $81.90 ❑ (no added/altered circuits) $80.90 ❑ Service change with added/altered circuits ................. $81.90 number of added circuits ....................... $11.55 ea ❑ Circuits added/altered without service change ........... $54.60 (up to 5 circuits) $10.80 ea ❑ Circuits added/altered without service change ........... $54.60 (6 or more circuits) ............................................... $7.65 ea ❑ Meter/mast repair ....................................................... $68.25 ❑ Low voltage systems ................................................. $59.85 (alarm, furnace thermostat) PERMIT APPLICATION NOTES - MULTI -FAMILY AND COMMERCIAL Fees are based on the valuation of the electrical contract. MISCELLANEOUS FEES ❑ Temporary service (residential) ................................. $65.00 ❑ Temporary service (generator) ................................... $80.90 ❑ Manufactured/mobile home service ........................... $86.25 (excluding garage or outbuilding) ❑ Carnivals.................................................................... $80.60 Number of concessions ......................... $10.80 ea Each ride and generator truck ............... $10.80 ea * * *EFFECTIVE JANUARY 1, 2014 EACH PERMIT WILL BE ASSESSED A 5% TECHNOLOGY FEE*** Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The Building Official may grant one extension of time for an additional period not to exceed 90 days. The extension shall be requested in writing and justifiable cause demonstrated. I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER OR ELECTRICAL CONTRACTOR: Print Name: ElaiaWainright rllro�,ex* Day Telephone Mailing Address: 12828 Northup Way Suite 205 Bellevue City H:\Applications\Forms-Applications On Line\2014 ApplicationsTlectrical Permit Application Revised 1-1-14.docx Revised: January 2014 bh Date: 12/13/2016 (206) 633-2811 WA 98005 State Zip Page 2 of 2 DESCRIPTIONS PermitTRAK ACCOUNT QUANTITY PAID $2,849.28 EL16-1161 Address: 3311 S 120TH PL 120TH Apn: 1023049078 $2,849.28 ELECTRICAL $2,739.69 PERMIT FEE MULTI-FAM/COMM R000.322.101.00.00 0.00 $2,191.75 PLAN CHECK FEE • R000.345.832.00.00 0.00 $547.94 TECHNOLOGY FEE $109.59 TECHNOLOGY FEE TOTAL114: R000.322.900.04.00 0.00 $109.59 $2,849.28 Date Paid: Thursday, December 15, 2016 Paid By: TITAN ELECTRIC INC Pay Method: CHECK 22343 Printed: Thursday, December 15, 2016 2:16 PM 1 of 1 CW SYSTEMS INSPECTION RECORD y� -3 Retain a copy with permit Wt INSPECTION NO. PERMIT N0. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Project:Type of Inspection: ip � � Al, Approved per applicable codes. 1-1 Corrections required prior to approval. I paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Address: 33 t� Date Called: Special Instructions: Date Wanted:�� a.m. Requester: Phone No: yy C Approved per applicable codes. 1-1 Corrections required prior to approval. I paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd.., #100, Tukwila. WA 98188 (206) 431-367 Permit Inspection Request Line (206) 438-9350 Project: 'ZType 10 of Inspection: Address:,3 3 s< Izo pt, Date Called: Special Instructions: Date Wanted: a. Requester: Phone No: Approved per applicable codes. Corrections required prior to approval. IJNJ El nspector: REINSPECTION FEE REQUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd.. Suite 100. Calt to schedule reinspection. 'INSPECTION RECORDC'Ujj�� INSPECTION N0. PErr Retain a copy with permit R RMIT N0. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Project: ZA-YO Type of Inspection: .5 —� Address: Date Called: Special Instructions: Date Wanted: a.m. rf p Requester: Phone No: —/y yqq LIApproved per applicable codes. Corrections required prior to approval. DVI pector: REINSPECTION(FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. PERMIT CQQRp COPY. PLAN REVIEW/ROUTING SLIP PERMIT NUMBER: EL16-1161 DATE: 12/15/16 PROJECT NAME: ZAYO SITE ADDRESS: 3311 S 120 PL - SUITE 120 X Original Plan Submittal Revision # before Permit Issued Response to Correction Letter # Revision # after Permit Issued DEPARTMENTS: �� ' � ,)C-, i�L46-ttf,, Building Division a Fire Prevention ❑ Planning Division ❑ Public Works ❑ Structural ❑ Permit Coordinator U PRELIMINARY REVIEW: DATE: 12/20/16 Not Applicable ❑ Structural Review Required ❑ (no approval/review required) REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: Approved ❑ Corrections Required ❑ (corrections entered in Reviews) Notation: REVIEWER'S INITIALS: DUE DATE: 01/17/17 Approved with Conditions e Denied ❑ (ie: Zoning Issues) DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: 12/18/2013 TITAN ELECTRIC INC C+Washington State Department of ,/ tabor & Industries TITAN ELECTRIC INC Owner or tradesperson Principals BURKE, PATRICK D, PRESIDENT CROOK, TRAVIS J, VICE PRESIDENT FLING, LAWRENCE H, SECRETARY FLING, LAWRENCE H, AGENT Doing business as TITAN ELECTRIC INC Horne Espaiiol Contact Safety & Health Claims & Insurance 12828 Northup Way Ste 205 BELLEVUE, WA 98005 206-633-2811 KING County WA UBI No. Business type 602 250 925 Corporation Governing persons LAWRENCE M FLING PATRICK DUNIVON BURKE; TRAVIS JAY CROOK; License Page 1 of 4 Search L&I -� A -Z Index I lelp My t &I Workplace Rights Trades & Licensing Verify the contractor's active registration / license / certification (depending on trade) and any past violations. Electrical Contractor Active. .............................................................. Meets current requirements. License specialties GENERAL License no. TITANE19630B Effective — expiration 09/02/2004— 09/02/2018 Designated administrator Active. CROOK, TRAVIS Meets current requirements. License type License no. Electrical Administrator CROOKT'011PB Bond ................ Lexon Ins Co $4,000.00 Bond account no. 9808431 Received by L&I Effective date 08/08/2011 08/03/2011 Expiration date Until Canceled Bond history Savings No savings accounts during the previous 6 year period. Help us improve https:Hsecure.Ini.wa.gov/verify/Detail.aspx?UBI=602250925&LIC=TITANEI963OB&SAW= 12/23/2016 TITAN ELECTRIC INC License Violations Infraction no. EMAB004230 Issue date 12/06/2013 Violation city SEATTLE Type of violation ELECTRICAL CITATION Description Failing to get an inspection or obtain an electrical/telecommunications work permit or post a provisional electrical work permit prior to beginning the electrical/telecommunication installation or alteration as referenced in WAC 296-466-901. Satisfied ......................... RCW/WAC 19.28.101 RCW Violation amount $5,000.00 Infraction no. EMAB004231 Satisfied ...........I .............. Issue date RCWWAC 12/06/2013 19.28.101 RCW Violation city Violation amount SEATTLE $20,000.00 Type of violation ELECTRICAL CITATION Description Failing to get an inspection or obtain an electrical/telecommunications work permit or post a provisional electrical work permit prior to beginning the electrical/telecommunication installation or alteration as referenced in WAC 296-46B-901. Infraction no. EMAB004232 Issue date 12/06/2013 Violation city SEATTLE Type of violation ELECTRICAL CITATION Description Failing to get an inspection or obtain an electrical/telecommunications work permit or post a provisional electrical work permit prior to beginning the electrical/telecommunication installation or alteration as referenced in WAC 296-466-901. Infraction no. EHUM100296 Issue date 08/14/2013 Violation city SEATTLE Type of violation ELECTRICAL CITATION Description Failing to get an inspection or obtain an electrical/telecommunications work permit or post a provisional electrical work permit prior to beginning the electrical/telecommunication installation or alteration as referenced in WAC 296-468-901. Satisfied ........ _............ RCWMAC 19.28.101 RCW Violation amount $8,000.00 Satisfied ... ........................ RCW/WAC 19.28.101 RCW Violation amount $1,000.00 Page 2 of 4 Help us improve https:Hsecure.Ini.wa.gov/verify/Detail.aspx?UBI=602250925&LIC=TITANEI963OB&SAW= 12/23/2016 TITAN ELECTRIC INC Infraction no. EHUM100297 Issue date 08/14/2013 Violation city SEATTLE Type of violation ELECTRICAL CITATION Description Failing to get an inspection or obtain an electrical/telecommunications work permit or post a provisional electrical work permit prior to beginning the electrical/telecommunication installation or alteration as referenced in WAC 296-466-901. Infraction no. EHUM100281 Issue date 08/05/2013 Violation city SEATTLE Type of violation ELECTRICAL CITATION Description Failing to get an inspection or obtain an electrical/telecommunications work permit or post a provisional electrical work permit prior to beginning the electrical/telecommunication installation or alteration as referenced in WAC 296-46B-901. Infraction no. ESHA000696 Issue date 05/17/2012 Violation city Seattle Type of violation ELECTRICAL CITATION Description Failing to obtain or post an electricalltelecommunications work permit prior to beginning the electrical/telecommunication installation or alteration as referenced in WAC 296-466-900 (3)(6), effective after 12/30/2008 see WAC 296- 4613-901. Workers' comp Satisfied RCW/WAC 19.28.101 RCW Violation amount $1,000.00 Satisfied ........._.............. RCW/WAC 19.28.101 RCW Violation amount $250.00 Satisfied ......................... RCW/WAC 19.28.101 RCW Violation amount $2,000.00 Do you know if the business has employees? If so, verify the business is up-to-date on workers' comp premiums. L&I Account ID Account is current. 045,686-00 Doing business as TITAN ELECTRIC INC Estimated workers reported Quarter 3 of Year 2016 "Greater than 100 Workers" L&I account representative T1 / NIKKI BUTLER (360)902-4918 - Email: BUT0235@lni.wa.gov Workplace safety and health Check for any past safety and health violations found on jobsites this business was responsible for. Page 3 of 4 https:Hsecure.Ini.wa.gov/verify/Detail.aspx?UBI=602250925&LIC=TITANEI963OB&SAW= 12/23/2016 TITAN ELECTRIC INC Washington State Dept. of Labor & Industries. Use of thi: subject to the laws of the state of Washington. Page 4 of 4 Help us improve https:Hsecure.Ini.wa.gov/verify/Detail.aspx?UBI=602250925&LIC=TITANEI963OB&SAW= 12/23/2016 P E c E U Li.. U U) 0 z <c 0 Q x m 0 N 0 'o z w i M 0 00 01>00 0 C14 i 0 i 2 3 4 5 6 7 8 1 9 10 11 12 13 14 ELECTRICAL RISER EQUIPMENT o EQUIPMENT CABINET ® ®E EQUIPMENT CONNECTION, E = EMERGENCY POWER Tr T -r GROUND BAR, LENGTH TO SCALE <>, MOTOR CONNECTION, SINGLE PHASE ,(De MOTOR CONNECTION, 3 PHASE POWER BUSWAY SPD 1 SURGE PROTECTIVE DEVICE QT TRANSFORMER, <30KVA, NOT TO SCALE 0 TRANSFORMER, 30KVA OR GREATER, DRAWN TO SCALE CIRCUITS —I� RACEWAY CONCEALED IN CEILING OR WALL HASH MARKS INDICATE NUMBER OF WIRES. #12 AWG WIRE UNLESS OTHERWISE NOTED. EXPOSED RACEWAY IS ALLOWED ONLY WHERE NOTED. —�— HOT (SHORT HASH MARK) ---F— NEUTRAL (LONG HASH MARK) —f— GROUND WIRE (JOGGED HASH MARK) EXISTING RACEWAY (IF HASH MARKS ARE SHOWN, PULL NEW CONDUCTORS) - - - - - RACEWAY BELOW SLAB OR UNDERGROUND —o RACEWAY UP RACEWAY DOWN RACEWAY STUB -OUT WITH BUSHING --2 CIRCUIT CONTINUATION HOME RUN TO PANEL OR LOCATION NOTED Q MJ JUNCTION BOX PB PULL BOX WORK DEFINITION FLAG NOTE ® REVISION IDENTIFICATION # EQUIPMENT IDENTIFICATION # EQUIPMENT IDENTIFICATION Det# DETAIL REFERENCE Sheet# Det# V DETAIL REFERENCE W/ORIGINATING SHEET REFERENCE PlanSheet# DetSheet# �# Sheet# SECTION REFERENCE v Sec# SECTION REFERENCE W/ORIGINATING SHEET REFERENCE PlanSheet# DetSheet# I Elev# ELEVATION REFERENCE Sheet# aPROJECT NORTH REFERENCE TnA loam PROJECT NORTH REFERENCE W/TRUE NORTH REFERENCE NEW WORK EXISTING ----- FUTURE jxxxx REMOVE EXISTING ELECTRICAL EQUIPMENT CONTROLS FUSED DISCONNECT SWITCH (FUSE RATING INDICATED) DISCONNECT SWITCH MOTOR STARTER MANUAL MOTOR STARTER COMBINATION MOTOR STARTER FUSED DISCONNECT SWITCH ENCLOSED CIRCUIT BREAKER © CONTACTOR Q r -.'l PUSH BUTTON CONTROL STATION -1- AUTO DOOR PUSHPLATE EMERGENCY SHUTDOWN M MOTOR RATED TOGGLE SWITCH BUSWAY PLUG FD_D_C_1 DIRECT DIGITAL CONTROL PANEL 0 RELAY, CONTROL TYPE OT THERMOSTAT TC TIME CLOCK FVFD_1 VARIABLE FREQUENCY DRIVE CIRCUITS LIGHTING EMERGENCY NORMAL 4nq WALL MOUNTED FIXTURE PANELBOARDS drm 208V SYSTEM PAWLBOARD 9:9 480V SYSTEM PANELBOARD LIGHTING SWITCHES AND CONTROLS - a LOWER-CASE I ET -ER NEAR SWITCH DENOTES CIRCUIT CONTROLLED (TYP) SINGLE POLE SWITCH 2 DOUBLE POLE SWITCH 3 3 -WAY SWITCH 4 4 -WAY SWITCH K KEY OPERATED SWITCH LV MOMENTARY CONTACT, LOW VOLTAGE SWITCH e OCCUPANCY SENSOR SWITCH P SWITCH WITH PILOT LIGHT PC PHOTOCELL SWITCH DIMMER SWITCH CS 1 CONTROL STATION, # INDICATES STATION IDENTIFICATION DSC DIMMING SYSTEM CONTROLS ELCU v. EMERGENCY LIGHTNG CONTROL UNIT OS CEILING MOUNTED OCCUPANCY SENSOR SWITCH PC PC PHOTOCELL CONTFOL PS PHOTO SENSOR CONTROL RELAY, NEC CLASS II QT LOW VOLTAGE TRANSFORMER CIRCUITS FEEDER SIZE IDENTIFICATION EMERGENCY AVAILABLE FAULT CURRENT IDENTIFICATION ® a ARRESTOR, SURGE a ARRESTOR, LIGHTNING aAUTOMATIC 0 TRANSFER SWITCH SPACE BUS SPACE AFF BUS DUCT MM BUSWAY END TAP BOX SPLIT WIRED RECEPTACLE, 120V, TOP SWITCHED CABLE TO BUS CONNECTION I CAPACITOR N/A �) CONTACT, NORMALLY OPEN AND NORMALLY CLOSED N/A CIRCUIT BREAKER COMBINATION RECEPTACLE 120/208V OR 120/24OV, SINGLE CIRCUIT BREAKER, DRAWOUT NEUTRAL CIRCUIT BREAKER, DRAWOUT, MEDIUM VOLTAGE GF NIC GF CIRCUIT BREAKER, GA AMERICAN WIRE GAUGE CIRCUIT BREAKER, GF] WITH DRAWOUT d'Z►-� CIRCUIT BREAKER, MAGNETIC OVERLOAD SINGLE RECEPTACLE 120V (TWIST LOCK) CIRCUIT BREAKER, NETWORK PROTECTOR C'1 -''XJ CIRCUIT BREAKER, THERMAL OVERLOAD 8 ®%J'A FUSE OR CURRENT LIMITER PB FUSE (ISOLATING) N/A CLOSED CIRCUIT TELEVISION •`�® FUSED SWITCH -L- GROUND POS PUSHBUTTON a SPLICE Q STRESS RELIEF, MEDIUM VOLTAGE N/A SWITCH, 2 -POLE H N/A A o � SWITCH, 3 -POLE 0 ® r)(:j THERMAL ELEMENT m TRANSFORMER (Q) TRANSFORMER, CURRENT ® TRANSFORMER, ELECTROSTATICALLY SHIELDED, MAGNETIC CORE SHOWN RECEPTACLE ® J r"v-w's TRANSFORMER, MAGNETIC CORE SHOWN ® FLOOR BOX (DEVICES AS INDICATED) N/A TRANSFORMER, SHIELDED, MAGNETIC CORE SHOWN aAMMETER 40 `:J CONTACTOR SINGLEMODE ENGINE -GENERATOR OKEY INTERLOCK O METER GPOWER METER O RELAY DOWN RELAY, GA ® SURGE PROTECTIVE DEVICE OVOLTMETER o WHM WATT HOUR METER EQUIPMENT o EQUIPMENT CABINET ® ®E EQUIPMENT CONNECTION, E = EMERGENCY POWER Tr T -r GROUND BAR, LENGTH TO SCALE <>, MOTOR CONNECTION, SINGLE PHASE ,(De MOTOR CONNECTION, 3 PHASE POWER BUSWAY SPD 1 SURGE PROTECTIVE DEVICE QT TRANSFORMER, <30KVA, NOT TO SCALE 0 TRANSFORMER, 30KVA OR GREATER, DRAWN TO SCALE CIRCUITS —I� RACEWAY CONCEALED IN CEILING OR WALL HASH MARKS INDICATE NUMBER OF WIRES. #12 AWG WIRE UNLESS OTHERWISE NOTED. EXPOSED RACEWAY IS ALLOWED ONLY WHERE NOTED. —�— HOT (SHORT HASH MARK) ---F— NEUTRAL (LONG HASH MARK) —f— GROUND WIRE (JOGGED HASH MARK) EXISTING RACEWAY (IF HASH MARKS ARE SHOWN, PULL NEW CONDUCTORS) - - - - - RACEWAY BELOW SLAB OR UNDERGROUND —o RACEWAY UP RACEWAY DOWN RACEWAY STUB -OUT WITH BUSHING --2 CIRCUIT CONTINUATION HOME RUN TO PANEL OR LOCATION NOTED Q MJ JUNCTION BOX PB PULL BOX WORK DEFINITION FLAG NOTE ® REVISION IDENTIFICATION # EQUIPMENT IDENTIFICATION # EQUIPMENT IDENTIFICATION Det# DETAIL REFERENCE Sheet# Det# V DETAIL REFERENCE W/ORIGINATING SHEET REFERENCE PlanSheet# DetSheet# �# Sheet# SECTION REFERENCE v Sec# SECTION REFERENCE W/ORIGINATING SHEET REFERENCE PlanSheet# DetSheet# I Elev# ELEVATION REFERENCE Sheet# aPROJECT NORTH REFERENCE TnA loam PROJECT NORTH REFERENCE W/TRUE NORTH REFERENCE NEW WORK EXISTING ----- FUTURE jxxxx REMOVE EXISTING ELECTRICAL EQUIPMENT CONTROLS FUSED DISCONNECT SWITCH (FUSE RATING INDICATED) DISCONNECT SWITCH MOTOR STARTER MANUAL MOTOR STARTER COMBINATION MOTOR STARTER FUSED DISCONNECT SWITCH ENCLOSED CIRCUIT BREAKER © CONTACTOR Q r -.'l PUSH BUTTON CONTROL STATION -1- AUTO DOOR PUSHPLATE EMERGENCY SHUTDOWN M MOTOR RATED TOGGLE SWITCH BUSWAY PLUG FD_D_C_1 DIRECT DIGITAL CONTROL PANEL 0 RELAY, CONTROL TYPE OT THERMOSTAT TC TIME CLOCK FVFD_1 VARIABLE FREQUENCY DRIVE CIRCUITS LIGHTING EMERGENCY NORMAL 4nq WALL MOUNTED FIXTURE PANELBOARDS drm 208V SYSTEM PAWLBOARD 9:9 480V SYSTEM PANELBOARD LIGHTING SWITCHES AND CONTROLS - a LOWER-CASE I ET -ER NEAR SWITCH DENOTES CIRCUIT CONTROLLED (TYP) SINGLE POLE SWITCH 2 DOUBLE POLE SWITCH 3 3 -WAY SWITCH 4 4 -WAY SWITCH K KEY OPERATED SWITCH LV MOMENTARY CONTACT, LOW VOLTAGE SWITCH e OCCUPANCY SENSOR SWITCH P SWITCH WITH PILOT LIGHT PC PHOTOCELL SWITCH DIMMER SWITCH CS 1 CONTROL STATION, # INDICATES STATION IDENTIFICATION DSC DIMMING SYSTEM CONTROLS ELCU v. EMERGENCY LIGHTNG CONTROL UNIT OS CEILING MOUNTED OCCUPANCY SENSOR SWITCH PC PC PHOTOCELL CONTFOL PS PHOTO SENSOR CONTROL RELAY, NEC CLASS II QT LOW VOLTAGE TRANSFORMER CIRCUITS RECEPTACLES EMERGENCY NORMAL AC 3" ABOVE COUNTER BACKSPLASH (b SINGLE RECEPTACLE 120V ACH ABOVE COUNTER HEIGHT DUPLEX RECEPTACLE 120V MANHOLE AFF DOUBLE DUPLEX RECEPTACLE 120V MM - SPLIT WIRED RECEPTACLE, 120V, TOP SWITCHED 4b 16 RECEPTACLE 208V OR 240V, SINGLE PHASE N/A 9 RECEPTACLE 208V OR 240V, THREE PHASE N/A 6 COMBINATION RECEPTACLE 120/208V OR 120/24OV, SINGLE N NEUTRAL PHASE N/A NIC RECEPTACLE 480V, SINGLE PHASE N/A AMERICAN WIRE GAUGE RECEPTACLE 48OV, THREE PHASE OPERATER/OPERABLE .(� SINGLE RECEPTACLE 120V (TWIST LOCK) . OWNER PROVIDED OWNER INSTALLED DUPLEX RECEPTACLE 120V (TWIST LOCK) N/A PB RECEPTACLE 208V OR 240V, SINGLE PHASE (TWIST LOCK) N/A CLOSED CIRCUIT TELEVISION RECEPTACLE 208V OR 240V, THREE PHASE (TWIST LOCK) N/A CKT COMBINATION RECEPTACLE 120/208V OR 120/24OV, SINGLE POS POSITION/POINT OF SALE PHASE (TWIST LOCK) N/A PR RECEPTACLE 48OV, SINGLE PHASE (TWIST LOCK) N/A CEILING MOUNTED RECEPTACLE 480V, THREE PHASE (TWIST LOCK) N/A COMM CLOCK RECEPTACLE 120V R ® SINGLE RECEPTACLE, FLUSH FLOOR BOX CONDUIT ® DUPLEX RECEPTACLE, FLUSH FLOOR BOX CO ® DOUBLE DUPLEX RECEPTACLE, FLUSH FLOOR BOX RECEPTACLE ® SPLIT WIRED RECEPTACLE, 120V, FLUSH FLOOR BOX N/A ® FLOOR BOX (DEVICES AS INDICATED) N/A @ POKE THROUGH (DEVICES AS INDICATED) 40 1$ SINGLE RECEPTACLE, CEILING MOUNTED SINGLEMODE 0 DUPLEX RECEPTACLE, CEILING MOUNTED SPECS SPECIFICATIONS DOUBLE DUPLEX RECEPTACLE, CEILING MOUNTED DEVICE Qj CEILING CORD DROP, 120V, SINGLE PHASE N/A DOWN POWER POLE N/A DW MULTI -OUTLET ASSEMBLY (DEVICES AS INDICATED) o TELECOM MUNICA110NS EPO DUPLEX RECEPTACLE, SURGE PROTECTOR TYPE DOUBLE DUPLEX RECEPTACLE, SURGE PROTECTOR TYPE GENERAL NOTES 1. COMPLY WITH THE NATIONAL ELECTRICAL CODE AS ADOPTED AND AMENDED BY THE LOCAL AUTHORITY HAVING JURISDICTION. 2. THE LOCATIONS OF ELECTRICAL DEVICES OR LIGHTING FIXTURES INDICATED ON ARCHITECTURAL PLANS ELEVATIONS OR SECTIONS TAKE PRECEDENCE OVER LOCATIONS INDICATED ON THE ELECTRICAL DRAWINGS. ABBREVIATIONS ABV ABOVE MCC MOTOR CONTROL CENTER AC 3" ABOVE COUNTER BACKSPLASH MDF MAIN DISTRIBUTION FRAME/FACILITY ACH ABOVE COUNTER HEIGHT MH MANHOLE AFF ABOVE FINISHED FLOOR MM MULTIMODE AG ABOVE GRADE MTD MOUNTED A,AMP AMPERE MW MICROWAVE A/V AUDIO/VISUAL N NEUTRAL ATS AUTOMATIC TRANSFER SWITCH NIC NOT IN CONTRACT AWG AMERICAN WIRE GAUGE OPER OPERATER/OPERABLE CAN COMMUNITY ACCESS TELEVISION OP01 OWNER PROVIDED OWNER INSTALLED CB CIRCUIT BREAKER PB PULLBOX CCN CLOSED CIRCUIT TELEVISION PNL PANEL, PANELBOARD CKT CIRCUIT POS POSITION/POINT OF SALE CLG CEILING PR PAIR CM CEILING MOUNTED PTS PNEUMATIC TUBE STATION COMM COMMUNICATIONS R RACEWAY C CONDUIT RO RACEWAY ONLY CO CONDUIT ONLY RECEPT RECEPTACLE CTRL CONTROL REF REFRIGERATOR CU COPPER SLV SLEEVE D DATA SM SINGLEMODE DED DEDICATED SPECS SPECIFICATIONS DEV DEVICE SW SWITCH DN DOWN SWBD SWITCHBOARD DW DISHWASHER TELECOM TELECOM MUNICA110NS EPO EMERGENCY POWER OFF TGB TELECOMMUNICATIONS GROUNDING EWC ELECTRIC WATER COOLER BUSBAR FA FIRE ALARM TMGB TELECOMMUNICATIONS MAIN FB FLOOR BOX GROUNDING BUSBAR FBOIC FURNISHED BY OTHERS, INSTALLED TSER TELECOMMUNICATIONS SERVICE BY CONTRACTOR ENTRANCE ROOM FI FILM ILLUMINATOR TV TELEVISION FO FIBER OPTIC(AL) TYP TYPICAL FOC FACE OF COLUMN OF UNDER FLOOR G,GND GROUND UG UNDER GROUND GD GARBAGE DISPOSAL UON UNLESS OTHERWISE NOTED GFI,GFCI GROUND FAULT CIRCUIT UTP UNSHIELDED TWISTED PAIR INTERRUPTER V VOLT OR VOICE HH HAND HOLE VEL VERIFY EXACT LOCATION HP HORSEPOWER W WIRE, WATT, OR WALLPHONE IDF INTERMEDIATE DISTRIBUTION WAP WIRELESS ACCESS POINT FRAME/FACILITY WP WEATHERPROOF IH INSTA-HOT WATER DISPENSER XFMR TRANSFORMER J -BOX JUNCTION BOX 0 PHASE MAG MAGNETIC ELECTRICAL SHEET INDEX SHEET NO. SHEET TITLE E-001 SYMBOLS & ABBREVIATIONS E-101 ELECTRICAL POWER PLAN E-102 MAIN ELECTRICAL ROOM LAYOUT & MCC -1 ELEVATION E-601 PARTIAL ELECTRICAL POWER RISER E-602 LOAD CALCULATIONS, PANEL SCHEDULES E-701 SPECIFICATION Total Number of sheets: 6 no.I date I by I ckd I description 1 111/04/161 JJJ I KWL I ISSUED FOR PERMIT SEr-v,'nx1 E P!:F PIT E,,U�tEJ FOR: M Mechaniraj EI ctrical ,. Pt bIng ElKas pipl-no Citbr of Tukwila REVISIONS No changes shall be ma a to th scope of viork %mithout prior approv of Tulm-, la Building Division NOTE: F.�:'Isiom will require a ne,v pla submittal and may Include additional plan revi w fees. I= con Permit , �zl0 ~11 1 Plan review approval is subject to a Mrs and omiozsions. Approval of construction document does not aut'ro :We the violation of any adopted code oi ordinance. Reczlpt of approved Field Copy 7dditics isacknowiedr,3d: By: Date: --___1z / 2A h/ City 0f BUILDING REVIEWED _FOR COMPLIANCE WITH NFPA 70 - NEC DEC 10 2016 J W \z- City ZCity of -Tukwila BUILDING DIVISION RECEIVED CITY OF TUKWILA DEC 15 2016 PERMIT CENTER } W' ,� = Vii. ��� Y': ••.VrI. 3 ON L Name Discipline License No. date 11/04116 designed U.MAMADAMINOV W J. KIM checked T. JANOF - .a Zayo Group Company ZAYO GROUP, LLC zCOLO - TUKWILA FACILITY 3311 INTERNATIONAL BLVD TUKWILA, WA 98188 SYLBOLS & ABBREVIATIONS project contract I CONTRACT drawing rev. .A -001 sheet 1 of 5 sheets file E001.DWG 0 A C C 0 F G H J E 0 U_ O LL N 3 U) N O E NE En L U C Pt P-05 FUTURE P-04 FUTURE P-03 - NEW P-02 - NEW P -01 - NEW 1 2 3 4 5 6 7 8 1 9 10 11 12 13 14 )7i'"IMtvw� fl� "vSY � j"�Uv DEC 16 2016 City 0f -`iUkWR RECEIVED CITY OF TUKWILA KWILA DEC 15 2016 PERMIT CENTER Name Discipline License No. no.I date I by I ckd I 1 111/04/161 JJJ I KWL description ISSUED FOR PERMIT 4100 194th Street SW Suite 400 Lynnwood Washington 98036-4613 (206) 667-0555 date 11/04/16 designed U.MAMADAMINOV detailed J. KIM checked T. JANOF _ _ a ,:2yo Group Ccmpany - ZAYO GROUP, LLC zCOLO - TUKWILA FACILITY 3311 INTERNATIONAL BLVD TUKWILA, WA 98188 ELECTRICAL PLAN project I contract CONTRACT drawing rev. -101 1 sheet 2 of 5 sheets file E101.DWG U D C 9 J E F C J E 2 U_ O T U 0 z M 0 a M x m Q 0 N 0 0 Z 0 w M I D Q co 0 C) i 0 i 1 2 GENERAL NOTES: 1. SET BREAKERS PER COORDINATION STUDY. FLAG NOTES: PROVIDE NEW LSI 700A, 65kAIC CIRCUIT BRE DEMOLISH EXISTING FEEDER AND BREAKER Al 3 : DEMOLISH EXISTING FEEDERS TO PUMPS, P1 RE -LABEL THEM AS 'SPARE' ON MCC -1. PROVIDE NEW 100A, 65kAIC CIRCUIT BREAKEI PROVIDE 2OA-1P BREAKER FOR CHILLER YAF 3 4 5 a SCL TRANSFORMER 4160/2400V DELTA J I I 7 8 9 10 11 12 TO DP1 DIST. PANEL100C3 100C3 100C3 TIE BREAKER 100C3 100C3 10 0 MECH C� 60OC4 CRA -2-B O O / / „NO" o (Q (4 (4 (4 (Q (4 Cn o ,S�R6 ,s9s� ,s26� 's S3 9 CRA -4-A 0 ATS -IB -MCC -A 600A 480V, 3PH-4W, 4 -POLE 42k AIC MECH MECH MECH CRA -3-A 600C4 CODE SIZE SPLICE BOX CRA -5-A )0C3 100C3 100C3 ATS CRA -1 THRU 5 100A MANUAL TRANSFER SWITCH 65K AIC, TYP 60OC4 60ONG 100AS 90AF CRAC-8 TXG-1 75kVA TRANSFORMER 480V PRIMARY 208/120V SECONDARY �T� PANEL I I I PANEL NEW BREAKER LIST FOR PANEL'LA' CIRCUIT NUMBER BREAKERSIZE CD (b Q (�CD 22 20A -1P, 10kAIC CHILLER YARD RECEPTACLE (GF) CD q 20A -1P, 10kAIC o v' 34 J CHILLER (CH -01) CONTROL CIRCUIT 100AS 90AF CRAC-8 TXG-1 75kVA TRANSFORMER 480V PRIMARY 208/120V SECONDARY �T� PANEL I I I PANEL �o MCC 600A 480/277V s9� NEW BREAKER LIST FOR PANEL'LA' CIRCUIT NUMBER BREAKERSIZE BREAKER DESCRIPTION 22 20A -1P, 10kAIC CHILLER YARD RECEPTACLE (GF) 32 20A -1P, 10kAIC CHILLER (CH -01) CONTROL CIRCUIT 34 15A -1P, 10kAIC CHILLER (CH -01) CONTROL CIRCUIT 36 20A -1P, 10kAIC CHILLER (CH -02) CONTROL CIRCUIT 38 15A-iP, 10kAIC CHILLER (CH -02) CONTROL CIRCUIT �o MCC 600A 480/277V s9� by I ckd I CD C) (bo Jo� -1, 80OC3 Cn C:)azo a- Z O Co Al -BATT1 4 O 600A I Q( o f Q( o f Q\ Q( �- a � ��® O O �®aC` �- O O N cn cn O O O o 0 I 600A ZZ Q O r� Q D' (O J O Q N L0- CONVRTR 52L "NC" q Ln �o q r� 1 0 800A/3P �U) 1-1/4'C, 3#4, 1 #8G S S 480V, 3PH-3W, 65K AIC VFD VFD VFD PANEL z(A z< T TXG-2 75kVA TRANSFORMER :E m :2 m 1-1/4'C, 3#4, 1#8G HB 480V PRIMARY 208/120V SECONDARY P-03 P-01 P-02 50HP 50HP 50HP PANEL LB (2) 3-1/2'C, 3-50OKCMIL, 1#1/OG (2) 3-1/2'C, 3-500KCMIL, 1#1/OG PANEL HM1 531 M) CA ��� j 80OC3 13 14 ATS -MV -13 ATS -MV -A 600A 600A 4160, 3PH-3W, 4160, 3PH-3W, 40K AIC, 3 -POLE 40K AIC, 3 -POLE 4160V TXMV1A 4160V 480/277SEC T 480/277SEC 2500 kVA2500 kVA NEMA 3R = by I ckd I CD C) (bo Jo� Fn 80OC3 Cn C:)azo a- Z O Co 80OC3 13 14 ATS -MV -13 ATS -MV -A 600A 600A 4160, 3PH-3W, 4160, 3PH-3W, 40K AIC, 3 -POLE 40K AIC, 3 -POLE 4160V TXMV1A 4160V 480/277SEC T 480/277SEC 2500 kVA2500 kVA NEMA 3R = BATT by I ckd I CD C) ( Fn 80OC3 cn - o a- Z O C D BATT by I ckd I description "A1 -BATTY BATT JJJ 80OC3 A1-BATT2" BATT 80OC3 Al -BATT1 600A I NEW 500kW 0 600A UPS -A1 Cl.- J� o 0 I 600A ZZ Q O K r� Q D' (O J O Q N L0- CONVRTR 52L "NC" q Ln �o q r� 1 0 800A/3P �U) U,U" S S 480V, 3PH-3W, 65K AIC S NINVR. S z(A z< (� :E m :2 m 80OC3 NEW 500kW UPS -Bi CONVRTR J CONVRTR INVR. (o CO Q ` (nn �o J 00 GFI 3000A s, s BATT BATT "B1 -BATTY BATT "61-BATT2" "B1 -BATT1 " 600A �� 600A o �600A � o 0 a - O ( J Q (O J N O Q N 00p� Co� Cl -LO BP -B1 800A PANEL 1 48OV, 3PH-3W, 65K AIC RECEIVED CITY OF TUKWILA DEC 15 2016 PERMIT CENTER no.I date I by I ckd I description 1 111/04/161 JJJ 80OC3 I 80OC3 "NO„ Cl.- a - ZZ Q O K r� Q D' (O J O Q N r7 Q( J O N — cin o0o J 52L "NC" q Ln �o q r� 1 0 800A/3P BP -A1 800A PANEL LSI 480V, 3PH-3W, 65K AIC 800C3 TO PANEL U1DP2 80OC3 NEW 500kW UPS -Bi CONVRTR J CONVRTR INVR. (o CO Q ` (nn �o J 00 GFI 3000A s, s BATT BATT "B1 -BATTY BATT "61-BATT2" "B1 -BATT1 " 600A �� 600A o �600A � o 0 a - O ( J Q (O J N O Q N 00p� Co� Cl -LO BP -B1 800A PANEL 1 48OV, 3PH-3W, 65K AIC RECEIVED CITY OF TUKWILA DEC 15 2016 PERMIT CENTER no.I date I by I ckd I description 1 111/04/161 JJJ I KWL I ISSUED FOR PERMIT 80OC3 0� 4100 194th Street SW Suite 400 Lynnwood Washington 98036-4613 (206) 667-0555 "NO" ff-) date detailed K m a - 11/04/16 J. KIM ')NC" 52L V) 000 J designed checked 800A/3P LSI U.MAMADAMINOV T. JANOF 800C3 TO PANEL ':' U 1 DP 1 a Zayo Group Company ZAYO GROUP, LLC zCOLO - TUKWILA FACILITY 3311 INTERNATIONAL BLVD d W:A,�`TUKWILA, WA 98188 ONAL a e Disci line License No. PARTIAL ELECTRICAL POWER RISER project I contract CONTRACT drawing rev. ®601 1 sheet 4 of 5 sheets file E601.DWG D C V F G H 0 L E E LrU 2 0 U_ T co Cn 0 Z a d x M M v- 0 N 0 0 z 0 i m i Q i 00 0 i C.) Q co C=) i 1 2 3 4 5 6 7 8 1 9 10 11 12 13 14 SECTION 260100 - GENERAL PROVISIONS PROVIDE COMPLETE AND FULLY OPERATIONAL ALL ELECTRICAL SYSTEMS WITHIN THE PROJECT AREA, ALONG WITH POWER CONNECTIONS TO EQUIPMENT FURNISHED UNDER OTHER DIVISIONS OF THE SPECIFICATIONS. A. CODES: CONFORM TO THE NATIONAL ELECTRICAL CODE AND ALL OTHER CODES AND REGULATIONS AS ADOPTED AND AMENDED BY THE STATE OF WASHINGTON AND CITY OF SEATTLE INCLUDING THE AMERICANS WITH DISABILITIES ACT (ADA). B. PERMITS AND FEES: CONTRACTOR TO OBTAIN AND PAY FOR ALL REQUIRED LICENSES, PERMITS AND INSPECTIONS. C. COORDINATION: CONTRACTOR TO COORDINATE ELECTRICAL WORK WITH OTHER TRADES. D. WARRANTY: PROVIDE WARRANTY FOR ONE FULL YEAR AFTER COMPLETION. E. CONTRACT DRAWINGS: RACEWAYS AND OUTLET BOXES ARE SHOWN DIAGRAMMATICALLY ONLY AND THE LAYOUT DOES NOT NECESSARILY SHOW THE TOTAL NUMBER OF RACEWAYS NOR THEIR EXACT LOCATION. THE CONTRACTOR SHALL PROVIDE ALL RACEWAYS, BOXES, CABLES, AND OTHER MATERIALS REQUIRED FOR THE COMPLETE ELECTRICAL SYSTEMS SHOWN OR INDICATED ON THE CONTRACT DRAWINGS. F. RECORD DRAWINGS: AT THE CONCLUSION OF CONTACT WORK, PROVIDE THE OWNER WITH A COMPLETE SET OF REPRODUCIBLE DRAWINGS WITH ALL CHANGES CLEARLY AND LEGIBLY MARKED TO REFLECT THE AS -BUILT CONDITIONS. THESE DRAWINGS SHALL BE LABELED "AS -BUILT" AND CERTIFIED BY THE CONTRACTOR FOR ACCURACY. G. MAINTENANCE MANUALS: COMPLETE FOR EVERY SYSTEM. HARDBOARD COVERS WITH 3 RING BINDERS. H. QUALITY ASSURANCE: 1. MATERIALS AND SYSTEMS: PROVIDE UL LISTED AND LABELED MATERIALS WHERE LISTING SERVICE IS NORMALLY PROVIDED FOR A GIVEN PRODUCT. PROVIDE NEW AND SHIP TO JOBSITE IN ORIGINAL MANUFACTURER'S CONTAINERS OR BUNDLES. 2. WORKMANSHIP: ARRANGE WORK TO OBTAIN COORDINATED INSTALLATION. 3. DRAWINGS: FOR PURPOSE OF CLARITY AND LEGIBILITY, THE DRAWINGS ARE ESSENTIALLY DIAGRAMMATICAL ONLY. 4. ROUTING: EXACT ROUTING OF WIRING AND LOCATIONS OF OUTLETS, PANELS, ETC. SHALL BE GOVERNED BY STRUCTURAL CONDITIONS, OBSTRUCTIONS AND EXISTING CONDITIONS. ARCHITECT RESERVES THE RIGHT AT NO INCREASE IN PRICE, TO MAKE REASONABLE CHANGES IN LOCATIONS OF ELECTRICAL ITEMS EXPOSED AT CEILING AND/OR ON WALLS. COORDINATION: 1. WORK OUT ALL "TIGHT" CONDITIONS INVOLVING WORK UNDER THIS CONTRACT IN ADVANCE OF INSTALLATION. 2. COORDINATE ALL ELECTRICAL POWER AND CONTROL WIRING REQUIREMENTS OF MECHANICAL EQUIPMENT WITH MECHANICAL CONTRACTOR. 3. CONTRACTOR SHALL COORDINATE ALL TENANT -FURNISHED EQUIPMENT LOCATIONS AND CONNECTION REQUIREMENTS WITH TENANT'S VENDOR PRIOR TO ROUGH -IN. CONTRACTOR SHALL MAKE ALL FINAL UNE VOLTAGE CONNECTIONS TO EQUIPMENT AS REQUIRED. 4. CONFIRM ALL ELECTRICAL EQUIPMENT AND SYSTEM PROGRAMMING NOMENCLATURE REQUIREMENTS WITH -IN. CONFORM TO ALL NAMING CONVENTIONS DEFINED THE OWNER PRIOR TO SUBMITTALS AND ROUGH THROUGHOUT THE PROJECT. SECTION 260126 - TESTING A. FURNISH ALL LABOR AND TEST EQUIPMENT AS REQUIRED UNDER THIS SECTION. B. FACILITIES ENGINEERING REPRESENTATIVE NEEDS TO BE PRESENT FOR FINAL TESTING. C. TEST ALL PANELS AND/OR BRANCH CIRCUITS FOR GROUNDS OR SHORTS. REPAIR DEFECTIVE WIRING AS REQUIRED. TEST EACH INDIVIDUAL CIRCUIT AT PANEL FOR PROPER OPERATION. D. AT COMPLETION OF WORK, PROVIDE WRITTEN CERTIFICATION THAT ALL SYSTEMS ARE FUNCTIONING PROPERLY WITHOUT DEFECTS. SECTION 260500 - BASIC MATERIALS AND METHODS INCLUDES GENERAL REQUIREMENTS FOR MATERIALS AND INSTALLATION METHODS, CUTTING BUILDING CONSTRUCTION, PAINTING, CLEAN-UP, AND WORKMANSHIP. A. MATERIALS: ALL MATERIALS SHALL BE NEW FREE FROM DEFECTS, AND SHALL HAVE BEEN TESTED AND LISTED BY UNDERWRITERS LABORATORIES OR OTHER APPROVED TESTING ORGANIZATION AND SHALL BE SO LABELED. B. SUBSTITUTIONS: SHALL BE REVIEWED BY THE ENGINEER. C. WORKMANSHIP: SHALL BE OF THE BEST QUALITY AND PERFORMED BY EXPERIENCED ELECTRICIANS UNDER SUPERVISION OF AN EXPERIENCED FOREMAN. D. NOISE TRANSMISSION: TO PREVENT NOISE TRANSMISSION (IN NEW CONSTRUCTION) BETWEEN ADJOINING ROOMS, ALL DEVICES ON OPPOSITE SIDES OF WALL TO BE SPACE A MINIMUM OF 6" APART (HORIZONTALLY PREFERRED). E. BRANCH CIRCUITING: NO MORE THAN SIX CURRENT CARRYING CONDUCTORS IN ANY ONE (1) HOMERUN. F. GROUNDING: PROVIDE SEPARATE GREEN GROUNDING CONDUCTOR IN ALL EQUIPMENT AND RECEPTACLE BRANCH CIRCUITS. SIZE PER NEC. G. SUBMITTALS: AFTER AWARD OF CONTRACT, SUBMIT THREE COMMON BOUND BROCHURES TO ENGINEER (ONE COPY RETURNED TO CONTRACTOR) CONTAINING CATALOG CUTS AND/OR SHOP DRAWINGS FOR THE FOLLOWING ITEMS: H. CUTTING AND PATCHING: DO NOT CUT STRUCTURAL MEMBERS. ALL CONSTRUCTION MATERIALS DAMAGED OR CUT INTO DURING THE INSTALLATION OF THIS WORK MUST BE REPAIRED OR REPLACED WITH MATERIALS BY SKILLED LABOR EXPERIENCED IN THAT PARTICULAR BUILDING TRADE. 1. PAINTING: TOUCH-UP TO MATCH FACTORY PAINT ANY ELECTRICAL ITEMS SCRATCHED OR MARRED IN SHIPMENT OR INSTALLATION. J. CLEAN UP: CONTINUALLY REMOVE DEBRIS, CUTTINGS, CRATES, CARTONS, ETC. CAREFULLY CLEAN WIRING DEVICES, COVER PLATES, LIGHT FIXTURES, ETC., TO REMOVE PAINT AND PLASTER, ETC. SECTION 260510 - EXISTING SYSTEMS A. EXISTING SYSTEMS AND SYSTEMS ADJACENT TO THE WORK SHALL BE INVESTIGATED THOROUGHLY. ANY DAMAGE RESULTING FROM PERFORMANCE OF WORK UNDER THIS CONTRACT SHALL BE REPAIRED TO ASSURE CONTINUING OPERATION AND INTEGRITY DURING AND AT COMPLETION OF THE PROJECT AT NO INCREASE IN CONTRACT COST. ANY EXISTING WIRING SERVING DEVICES TO REMAIN IN SERVICE AND WHICH IS INTERRUPTED BY WORK PERFORMED UNDER THIS CONTRACT SHALL BE REROUTED TO MAINTAIN CIRCUIT CONTINUITY. CONTRACTOR SHALL ASSUME THE RISK OF MAINTAINING EXISTING SYSTEMS EXCEPT RELOCATION OF WIRING OF #2 AWG AND ABOVE SHALL BE CONSIDERED AN ADDITIONAL COST IF NOT SHOWN TO BE RELOCATED. IF SUCH WIRING IS FOUND THE CONTRACTOR SHALL NOTIFY ENGINEER OF WIRING LOCATION, REASON IT MUST BE REMOVED AND COST OF RELOCATION AND RECEIVE THE OWNER'S APPROVAL BEFORE PROCEEDING WITH THE WORK. THE BUILDING WILL CONTINUE OPERATION DURING THE WORK AND IT IS ESSENTIAL THAT NO SYSTEMS OPERATION BE INTERRUPTED UNLESS SCHEDULED WITH THE OWNER. CONTRACTOR SHALL ASSUME RESPONSIBILITY FOR UNSCHEDULED INTERRUPTIONS AND EXPEDIENT REPAIR. B. ALL CEILING AREAS IN PROJECT AREA. VERIFY THAT EXISTING RACEWAY SUPPORT SYSTEM FOR ALL EXISTING TO REMAIN RACEWAYS ABOVE EXISTING OR NEW ACCESSIBLE CEILINGS IS INSTALLED PER CODE. ADD NEW SUPPORTS AS NECESSARY. C. EXISTING SYSTEMS CONCEALED 1. THE ELECTRICAL DRAWINGS SHOW PORTIONS OF THE EXISTING ELECTRICAL SYSTEMS WHICH ARE TO REMAIN, BE REMOVED OR BE MODIFIED AS A PART OF THE CONTRACTOR'S WORK. CONCEALED FEATURES OF THE EXISTING SYSTEMS ARE DERIVED FROM RECORD DRAWINGS AND THE ENGINEER'S BEST JUDGMENT OF THE CONFIGURATION, BUT NO GUARANTEE IS MADE AS TO THEIR CORRECTNESS. 2. THE CONTRACTOR SHALL INSPECT THE EXISTING INSTALLATION PRIOR TO BIDDING AND SHALL MAKE HIS OWN JUDGMENT AS TO THE WORK REQUIRED TO PROVIDE A COMPLETE INSTALLATION AND DEMOU11ON WITHIN THE INTENT OF THE CONTRACT DOCUMENTS. D. EXISTING SYSTEM DRAWINGS THE DRAWINGS SHOW PORTIONS OF THE EXISTING SYSTEMS WHICH ARE DERIVED FROM RECORD DRAWINGS. THE DRAWINGS ARE INCOMPLETE AND NO GUARANTEE IS MADE TO THEIR CORRECTNESS. THE CONTRACTOR SHALL ASSUME THERE IS 20% MORE ELECTRICAL SYSTEMS THAN SHOWN ON THE DEMOLITION AND EXISTING SYSTEM DRAWINGS. E. DEMOLITION WORK ALL DEMOLITION WORK REQUIRED UNDER THIS CONTRACT IS NOT SHOWN ON THE DRAWINGS. THE CONTRACTOR SHALL REMOVE ALL ELECTRICAL EQUIPMENT IN THE AREA BEING REMODELED WHICH IS NO LONGER IN SERVICE PRESENTLY OR AS A RESULT OF THIS CONTRACT. THE DEFINITION OF ELECTRICAL EQUIPMENT IS ANY EQUIPMENT MENTIONED IN THE NATIONAL ELECTRICAL CODE. F. TEMPORARY ELECTRICAL EQUIPMENT REMOVING, TEMPORARY HANGING BY CHAINS AND REINSTALLING IN CEILINGS OF LIGHT FIXTURES, SPEAKERS, DETECTORS, EXIT SIGNS AND OTHER ELECTRICAL EQUIPMENT IS NOT SHOWN ON THE DRAWINGS. THE CONTRACTOR SHALL INVESTIGATE THE CEILING DEMOLITION WORK AND INCLUDE THIS WORK IN THE BID. THE SEQUENCE OF WORK SHALL BE (1) REMOVE AND STORE FIXTURES, DETECTORS AND SPEAKERS ALONG WITH REMOVAL OF CEILING, (2) PROVIDE TEMPORARY SUPPORT FOR WIRED FIXTURES AND DEVICES TO BE REINSTALLED IN NEW CEILING AT APPROXIMATELY THE SAME LOCATION. USE CHAINS FOR LIGHTING FIXTURE SUPPORT, (3) CLEAN AND REINSTALL 1N THE NEW OR REPLACED CEILINGS, PROVIDE NEW LAMPS WHEN SO NOTED. PROVIDE TEMPORARY RELOCATION OF EXIT SIGNS CONNECTED TO EXISTING EMERGENCY CIRCUITS AND REINSTALL IN THE ORIGINAL LOCATION WHEN EXIT IS REACTIVATED. G. PREMIUM TIME PREMIUM TIME SHALL BE INCLUDED IN THE BASE BID FOR ELECTRICAL SYSTEM(S) OUTAGES AND FOR OTHER WORK AS REQUIRED BY THE SCHEDULE, AS SHOWN ON THE DRAWINGS AND AS NOTED IN OTHER DIVISIONS OF THE SPECIFICATIONS. H. WORK OUTSIDE OF REMODEL AREAS CAUTION - THIS WORK IS NOT SHOWN ON THE CONTRACT DOCUMENTS. PROVIDE NEW WIRING SYSTEMS IN CONCEALED CEILING SPACES TO SWITCHBOARDS, PANELBOARDS, COMMUNICATION AND SIGNALING AND SYSTEM CONTROL PANELS. PROVIDE NEW CONDUIT SYSTEMS IN CEILING SPACES OF FLOOR BELOW REMODEL FLOORS. REMOVE AND RELOCATE ELECTRICAL EQUIPMENT IN THE WAY OF OTHER TRADES WORK INSTALLED UNDER THIS CONTRACT. SPACES ABOVE EXISTING CEILINGS ARE HIGHLY CONGESTED. ROUTE WIRING AROUND OBSTRUCTIONS AND PROVIDE PULL BOXES PER CODE. I. EXISTING MATERIALS ALL MATERIALS WHICH ARE A PART OF THE BUILDING SHALL REMAIN THE PROPERTY OF THE OWNER. J. EXISTING MATERIALS TO BE REINSTALLED EXISTING MATERIALS AND EQUIPMENT (EXCEPT INTERIOR, UNDAMAGED RACEWAYS) THAT ARE REMOVED AS A PART OF THE WORK OR STORED IN SURPLUS SHALL NOT BE REINSTALLED AS A PART OF THE NEW SYSTEMS UNLESS SPECIFICALLY NOTED OR AUTHORIZED IN WRITING BY THE OWNER. FORWARD A COPY OF THE AUTHORIZATION TO THE ENGINEER. THE REQUIREMENTS OF THE SPECIFICATIONS (I.E., CONDITION, INSTALLATION, TESTING, ETC.) SHALL APPLY AS IF THE MATERIALS WERE NEW, FURNISHED BY THE CONTRACTOR. K. EXISTING MATERIALS NOT TO BE REINSTALLED ALL MATERIAL TO BE DEMOLISHED AND DEBRIS SHALL BE LEGALLY DISPOSED OF BY THE CONTRACTOR. L EXISTING RACEWAYS THE CONTRACTOR MAY REUSE THE EXISTING RACEWAYS IF NO OTHER SYSTEMS OCCUPY THE RACEWAY, RACEWAYS AND ENCLOSURES ARE ELECTRICALLY AND MECHANICALLY CONTINUOUS AND NEW WIRING IS PROVIDED. NO WARRANTY IS MADE AND THE CONTRACTOR SHALL ASSUME THE RISK OF USING EXISTING OUTLET BOXES AND RACEWAY SYSTEMS. M. EXISTING CONDITIONS EXAMINE THE STRUCTURE, BUILDING, AND CONDITIONS UNDER WHICH ELECTRICAL WORK IS TO BE INSTALLED FOR CONDITIONS DETRIMENTAL TO PROPER AND TIMELY COMPLETION OF ELECTRICAL WORK. DO NOT PROCEED WITH WORK UNTIL DEFICIENCIES OR DETRIMENTAL CONDITIONS HAVE BEEN CORRECTED. REPORT DEFICIENCIES OR DETRIMENTAL CONDITIONS OF EXISTING ELECTRICAL WORK WHICH MIGHT BE UNSUITABLE TO CONNECT WITH OR RECEIVE OTHER WORK. FAILURE TO SO REPORT SHALL CONSTITUTE ACCEPTANCE OF OTHER WORK AS BEING FIT AND PROPER FOR THE RECEPTION OF ELECTRICAL WORK. N. EXISTING SYSTEMS MAINTAINED GENERAL REROUTE EXISTING CIRCUITS THAT ARE INTERRUPTED AS A RESULT OF THIS CONTRACT THAT SERVE DEVICES TO REMAIN IN SERVICE. 1. POWER CIRCUITS TRACE OUT AND IDENTIFY LOADS AND SYSTEMS BEING SERVED. PROVIDE TEMPORARY WIRING, SCHEDULE OUTAGE AND RECONNECT LOADS TO TEMPORARY WIRING. PROVIDE NEW WIRING IN NEW LOCATION. SCHEDULE OUTAGE, DISCONNECT TEMPORARY WIRING, AND CONNECT LOADS TO NEW WIRING. 2. SIGNAL AND COMMUNICATION SYSTEMS TRACE OUT AND IDENTIFY DEVICE AND SYSTEMS BEING SERVED. PROVIDE TEMPORARY WIRING TO MAINTAIN OPERATION OF SYSTEM THROUGHOUT FACILITY. SCHEDULE OUTAGE AND CONNECT TO TEMPORARY WIRING AND TEST SYSTEM. PROVIDE NEW WIRING AND NEW EQUIPMENT IN PROJECT AREA. SCHEDULE OUTAGE, DISCONNECT TEMPORARY WIRING AND CONNECT NEW WIRING AND NEW EQUIPMENT AND TEST SYSTEM. 0. DEMOLITION SIGNALING AND COMMUNICATION SYSTEMS, LIGHTING FIXTURES, OTHER ELECTRICAL EQUIPMENT FREE STANDING OR SURFACE MOUNTED, RACEWAY (EXPOSED) AND CONDUCTORS; WHICH ARE NO LONGER IN SERVICE PRESENTLY OR AS A RESULT OF THIS CONTRACT SHALL BE REMOVED. UNUSED FLUSH MOUNTED DEVICES, OUTLET AND OTHER BOXES IN FINISHED AREAS SHALL BE REMOVED FROM WALL AND THE REMAINING HOLE PATCHED TO MATCH ADJACENT WALL SURFACES. UNUSED RACEWAYS AND SLEEVES EMBEDDED IN CONCRETE SHALL BE CUT FLUSH AT CEILING, FLOOR OR WALL AND FILLED WITH GROUT. ALL UNUSED RACEWAYS ABOVE CEILINGS SHALL BE REMOVED. CONTRACTOR SHALL REMOVE ALL FLOOR, WALL OR CEILING MOUNTED ELECTRICAL EQUIPMENT IN THE "DEMOLITION AREA" INDICATED ON THE DRAWINGS EVEN IF THE EQUIPMENT/OR DEVICE IS NOT SHOWN ON THE PROJECT DRAWINGS. IF CONTRACTOR QUESTIONS WHETHER A PARTICULAR DEVICE IS TO BE REMOVED NOTIFY THE ENGINEER NOTING TYPE AND LOCATION OF DEVICE. IF SO DIRECTED THE CONTRACTOR SHALL MAINTAIN THE EXISTING DEVICE IN SERVICE WITHOUT ANY CHANGE IN CONTRACT PRICE. P. POWER OUTAGES 1. SCHEDULED OUTAGES. THE EXISTING FACILITY WILL CONTINUE ITS NORMAL OPERATION DURING THE CONSTRUCTION WORK; THEREFORE IT IS REQUIRED THAT THE CONTRACTOR SCHEDULE ELECTRICAL SYSTEM(S) OUTAGES WITH THE OWNER OR BUILDING MANAGEMENT. SUBMIT A WRITTEN REQUEST FOR A POWER OUTAGE AT LEAST ONE WEEK IN ADVANCE IDENTIFYING THE AREAS, AND SYSTEMS THAT WILL BE AFFECTED, TIME AND DURATION OF THE POWER OUTAGE. THE CONTRACTOR SHALL RECEIVE WRITTEN AUTHORIZATION TO PROCEED WITH THE OUTAGE AND SHALL RE -NOTIFY THE OWNER OR BUILDING MANAGEMENT VERBALLY AT LEAST ONE HOUR PRIOR TO THE OUTAGE AND ALSO N011FY THE OWNER WHEN THE OUTAGE IS COMPLETED. 2. UNSCHEDULED OUTAGES, IN THE EVENT THAT THE CONTRACTOR'S WORK CAUSES OR CONTRIBUTES TO AN UNSCHEDULED SYSTEM(S) OUTAGE (OR OTHER SYSTEM FAULT), THE CONTRACTOR IS RESPONSIBLE FOR IMMEDIATELY CORRECTING THE PROBLEM. INCLUDED (AS EXAMPLES) SHALL BE ANY PREMIUM TIME REQUIRED TO STAY ON TFE JOB SITE UNTIL PROBLEM IS CORRECTED AND AIR FREIGHT FOR PARTS NOT LOCALLY AVAILABLE. Q. ACCESS TO PERFORM WORK CAREFULLY REMOVE, STORE OR TEMPORARILY HANG AND RE -INSTALL IN UNDAMAGED CONDITION ALL ELECTRICAL EQUIPMENT, LGHTING FIXTURES AND CEILING 11LES WHERE ACCESS TO PERFORM WORK IS REQUIRED. CLEAN PRIOR 10 RE -INSTALLATION. R. NEW DEVICES IN REMODEL AREAS PROVIDE FLUSH MOUNTING FOR DEVICES IN EXISTING WALLS. FISH CONDUIT IN WALL WHERE EXISTING BOXES ARE INDICATED TO BE REUSED, EXTEND BOX AS NECESSARY AND PROVIDE NEW DEVICES AND PLATES. CONTRACTOR IS CAUTIONED THAT THE EXISTING BUILDING CONTAINS CLAY TILE AND CONCRETE WALLS. NEW DEVICES MAY REQU',RE CUTTING, PATCHING, AND PAINTING OF WALLS AND IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO PROVIDE ALL CUTTING, PATCHING AND PAINTING REQUIRED FOR THE INSTALLATION OF THE DIVISION 16 WORK. CONTRACTOR SHALL INVESTIGATE EXISTING AREAS PRIOR TO BID AND SHALL INCLUDE ALL COSTS OF SUCH WORK IN THE BID. THIS FACILITY HAS WIRING EMBEDDED IN RACEWAYS IN CONCRETE SLABS. PROVIDE NEW CONCEALED WIRING TO LAST OUTLET OR PULL BOX BEFORE HOMERUN TO PANEL. SECTION 260519 - LOW VOLTAGE ELECTRICAL POWER CONDUCTORS AND CABLES A. PROVIDE ALL WIRE AND CABLE COMPLETE. COPPER, INSULATED FOR 60OV. ALUMINUM OR COPPER CLAD ALUMINUM CONDUCTORS NOT PERMITTED. TYPE THW, THWN/THHN OR XHHW. NUMBER 12 AWG MINIMUM FOR POWER AND LIGHTING CIRCUITS. B. SPLICES: SOLDERLESS TYPE ONLY. PRE -INSULATED "TWIST -ON" TYPE (LIMITED TO SIZE #10 AND SMALLER). BOLT OR COMPRESSION .SET T)PE WITH APPLICATION OF PREFORMED INSULATED COVER, HEAT SHRINKABLE TUBING OR PLASTIC INSULATED TAPE ACCEPTABLE FOR ALL SIZES. C. TERMINATIONS: COMPRESSION SET, BOLTED OR SCREW TERMINAL CONDUCTORS #12 AND SMALLER SHALL UTILIZE EYE OR FORKED TONGUE TYPE COMPRESSION SET TERMINATOR WHEN TERMINATION IS TO A BOLTED SCREW SET TYPE TERMINAL BLOCK OR TERMINAL CABINET. D. COLOR CODE: 480 MARKING BRN, ORG, YELL, GRAY NEUTRAL 208 MARKING BLK, RED, BLU, WHITE NEUTRAL E. BRANCH CIRCUITS: COPPER. SOLID FOR NO.10 AWG AND SMALLER; STRANDED FOR NO.8 AWG AND LARGER. F. MULTICONDUCTOR CABLE IS PERMITTED ONLY AS DETAILED IN THE DRAWINGS. COMPLY WITH NEMA WC 70 FOR ARMORED CABLE, TYPE AC METAL -CLAD CABLE, TYPE MC AND TYPE SO WITH GROUND WIRE. G. ALL 480/277V WIRING WILL BE SEPARATED FROM THE 208/120V WIRING AT ALL TIMES. EXCEPTIONS: MOTOR CONTROLS. SECTION 260526 - GROUNDING PROVIDE A GROUNDING SYSTEM FOR EQUIPMENT AND DEVICE GROUND AS REQUIRED BY CODE. A. ALL NEW AND EXISTING RECEPTACLES TO HAVE GROUNDED POLES. SECTION 260533 - RACEWAYS AND BOXES A. PROVIDE RACEWAY SYSTEM COMPLETE AND IN CONFORMANCE WITH CODE. INSTALL RACEWAYS CONCEALED IN CONSTRUCTON FOR ALL AREAS UNLESS EXPOSED RACEWAYS ARE SPECIFICALLY SHOWN. B. PROVIDE 1" RACEWAY FOR HOMERUNS AND MAJOR CEILING CONDUIT RUNS. RACEWAY DROPS DOWN WALLS AND RACEWAY CARRYING 2 CURRENT CARRYING CONDUCTORS CAN BE 3/4". MINIMUM RACEWAY SIZE IS 3/4". C. PROVIDE PULLWMRE IN ALL EMPTY RACEWAYS. D. INTERIOR RACEWAYS: ELECTRICAL METALLIC TUBING (EMT) WITH STEEL COMPRESSION OR SET SCREW FITTINGS. INDENTOR, DRIVE -ON AND PRESSURE CAST ON DIE CAST TYPE SET SCREW FITTINGS ARE NOT ACCEPTABLE. E. RACEWAY PENETRATIONS: PENETRATIONS THROUGH FIRE RATED CONSTRUCTION SHALL BE SEALED USING 3M FIRE BARRIER CAULK, NELSON ELECTRIC FLAMESEAL OR T & B FLAMESAFE OR USE OTHER METHOD APPROVED BY THE ARCHITECT. F. PROVIDE AND SIZE OU -LET BOXES FOR DEVICES SUCH AS RECEPTACLES, SWITCHES AND LIGHT FIXTURES AND PULL BOXES AS REQUIRED IN THE CONDUIT SYSTEM PER THE NATIONAL ELECTRICAL CODE. CONTRACTOR SHALL COORDINATE WITH GENERAL CONTRACTOR TO DETERMINE ANY SPECIALTY INSTALLATION REQUIREMENTS DUE TO FIRE RATINGS, CORE WALLS, ETC. G. INTERIOR WIRING: PRESSED STEEL, ZINC COATED WITH PLASTER RING WHERE APPLICABLE. MOUNT OUTLET BOXES FOR RECEPtACLES AND OTHER DEVICES AT 18", UNLESS OTHERWISE NOTED. C. RECEPTACLES: 208V SINGLE PHASE RECEPTACLES: PROVIDE NEMA TYPE RECEPTACLES AS INDICATED ON DRAWINGS. DEVICES SHALL BE UL LISTED. PROVIDE DEVICES FROM ACCEPTABLE MANUFACTURERS; HUBBELL, LEVITON, PASS & SEYMOUR. GROUND FAULT CIRCUIT INTERRUPTER (GFCI) RECEPTACLE: SPECIFICATION GRADE, NEMA 5-15R CONFIGURATION, DUPLEX RECEPTACLE WITH 4-6 MILLIAMPS LEAKAGE CURRENT TRIP LEVEL FEED THROUGH TYPE TO PROTECT DOWNS -REAM RECEPTACLES ON THE SAME CIRCUIT. HUBBELL GFR5352L, LEVITON 7590 OR PASS & SEYMOUR 2095. COMBINATION GROUND FAULT CIRCUIT INTERRUPTER (GFCI) / SAFETY RECEPTACLE: COMBINATION U.L LISTED GFCI AND TAMPER RESISTANT RECEPTACLE, AUTOMATIC MECHANICAL SHUTTER TO PREVENT OBJECTS FROM BEING INSERTED INTO RECEPTACLES. PASS & SEYMOUR 2095TR, HUBBELL GFTR20. D. INTERIOR DEVICE PLATES: STAINLESS STEEL WITH 302 SATIN FINISH. E. IDENTIFICATION: EMERGENCY RECEPTACLES DEVICE PLATES SHALL BE LABELED WITH "EMERGENCY" ABOVE THE RECEPTACLE IN 3/16" HIGH RED FILLED LETTERS ALSO LABELED BELOW THE RECEPTACLE THE PANELBOARD AND CIRCUIT NUMBER SERVING THE RECEPTACLE. NORMAL RECEPTACLE DEVICE PLATES SHALL BE LABELED BELOW WITH PANELBOARDS AND CIRCUIT NUMBER (BLACK FILLED LETTERS). RECEPTACLE COVERPLATES FOR RECEPTACLES OTHER THAN 15 AND 20 AMP SHALL BE LABELED WITH AMPERE RATING, VOLTAGE AND PHASE. UTILIZE MACHINE PRINTED ADHESIVE FILM LABELS BY THERMAL TRANSFER OR EQUIVALENT PROCESS. F. PROVIDE A GFCI RECEPTACLE WITHIN 5'-0" OF ALL WATER SOURCES. ���II�P►i►�:��:3I��I1�d�1�1i+1��lI,YPI�l11�'ix�)�y;'J<t�1:1�� A. PROVIDE STANDARD DUTY TYPE DISCONNECT SWITCHES FOR EQUIPMENT, SIZED PER CODE. EQUIPMENT SIZING SHOWN ON DRAWINGS SHALL BE CONFIRMED AND REVISED AS REQUIRED TO MEET NEC. B. FUSES TO BE SIZED AS DIRECTED BY MECHANICAL EQUIPMENT MANUFACTURER. C. WEATHER PROOF SWITCHES NOTED "WP" TO BE NEMA 3R LISTED EQUIPMENT. D. IDENTIFICA11ON: PROVIDE ENGRAVED PHENOLIC NAMEPLATE FOR ALL DISCONNECTS. FOR EQUIPMENT CONNECTED TO EMERGENCY PROVIDE 3/16" HIGH WHITE FILLED LETTERS ON RED BACKGROUND IDENTIFYING EQUIPMENT SERVED AND THE PANELBOARD AND CIRCUIT NUMBER SERVING THE EQUIPMENT. FOR EQUIPMENT CONNECTED TO NORMAL PROVIDE 3/16" HIGH WHITE FILLED LETTERS ON BLACK BACKGROUND IDENTIFYING EQUIPMENT SERVED AND THE PANELBOARD AND CIRCUIT NUMBER SERVING THE EQUIPMENT SECTION 270533 - CONDUITS AND BACKBOXES FOR COMMUNICATIONS SYSTEMS PROVIDE OUTLET BOXES AND RACEWAYS READY FOR THE INSTALLATION OF COMMUNICATION CABLES BY OWNER. A. OUTLET BOXES: 4" SQUARE, 2" DEEP WITH SINGLE DEVICE PLASTER RING. B. COVERPLATES: BY OWNER. C. RACEWAYS: 3/4" FOR UP TO 4 CABLES, 1" FOR UP TO 6 CABLES WITH PLASTIC BUSHING ON ALL RACEWAY ENDS. ROUTE RACEWAY TO ABOVE ACCESSIBLE CEILING SPACE. CONFIRM AT BIDDING PERIOD ALL ROUTING REQUIREMENTS WITH OWNER FOR RACEWAY QUANTITIES AT BIDDING. PROVIDE PULL -STRING. E. IDENTIFICATION LABELS COMPLY WITH TTA/EIA-606-A AND APPLICABLE REQUIREMENTS IN THIS SECTION. MACHINE PRINTED SELF-ADHESIVE, SMUDGE RESISTANT LABELS FOR CABLES AND FACE -PLATES. LABELS SHALL BE APPROPRIATELY SIZED FOR CABLE DIAMETER. LABELS SHALL BE APPROPRIATELY COLORED FOR FACE -PLATE COLOR CONTRAST. SUBMIT SAMPLE LABELS FOR APPROVAL F. FOLLOW MANUFACTURERS' INSTRUCTIONS FOR INSTALLING COMPONENTS AND ADJUSTING ALL EQUIPMENT AND TELECOMMUNICATIONS CABLES. WHERE NO INSTRUCTIONS ARE INCLUDED WITH THE EQUIPMENT, FOLLOW ACCEPTED INDUSTRY PRACTICES AND WORKMANLIKE INSTALLATION STANDARDS. G. KEEP ALL ITEMS PROTECTED BEFORE AND AFTER INSTALLATION, WITH DUST AND WATER PROOF BARRIER MATERIALS AS NECESSARY. THE CONTRACTOR SHALL BE RESPONSIBLE TO ENSURE THE INTEGRITY OF THE PROTECTIVE MEASURES THROUGHOUT THE LIFE OF THE PROJECT. H. COMPLY WITH BICSI TCI, TIA/EIA-568-B.1, TIZ/EIA-568-B.2, TTA/EIA-568-8.3, AND TIA/EIA-569-A. I. 4 -PAIR UTP CABLE INSTALLATION PROVIDE 4 -PAIR UTP CABLES FROM THE IDF ROOMS TO THE COMMUNICATION OUTLETS AS SHOWN ON THE DRAWINGS. TERMINATE THE CABLES ONTO 8 -PIN MODULAR PANELS IN THE IDF AND ONTO 8 -PIN MODULAR CONNECTORS AT THE OUTLET LOCATION. ROUTE THE CABLES IN THE ACCESSIBLE CEILING AREA. SUPPORT THE CABLES WITH J -HOOKS INSTALLED AT A MAXIMUM SEPARATION OF 48 -INCHES IN ROUTE BACK TO THE CABLE TRAYS. DO NOT ALLOW UTP CABLES TO RUN PARALLEL WITH' ELECTRICAL CABLES/CONDUITS, UNLESS THEY ARE SEPARATED BY A MINIMUM OF 12 INCHES. ANY TELECOMMUNICATIONS CABLES THAT MUST CROSS OVER ELECTRICAL CABLES/CONDUITS SHALL DO SO ONLY AT 90 -DEGREE ANGLES. J. PROVIDE CATEGORY 6 8 -PIN MODULAR CONNECTORS FOR THE TERMINATION OF ALL 4 -PAIR CABLES. PROVIDE AN ACCOMPANYING FACEPLATE AND/OR MOUNTING PLATE AT THE APPROPRIATE OUTLET LOCATION. INSTALL FACEPLATES LEVEL AND ALIGN TO ADJACENT OUTLET FACEPLATES. K. IDENTIFICATION PROVIDE ON ALL OUTLET FACEPLATES INSTALLED UNDER THIS WORK, MACHINE -GENERATED LABELS WITH THE OUTLET ID, IN UPPERCASE LETTERING. LABEL SHALL BE OF A CONTRASTING COLOR TO THE FACEPLATE COLOR. PROVIDE ON ALL TERMINATION BLOCKS INSTALLED UNDER THIS WORK, MACHINE -GENERATED DESIGNATION STRIPS WITH THE CABLE ID AND PAIR NUMBER, IN UPPERCASE LETTERING. RECEIVED CITY OF Tt KWiLA DEC 15 2016 PERMIT CENTER Name Discipline License No. 4100 194th Street SW Suite 400 Lynnwood Washington 98036-4613 (206) 667-0555 11/04/16 designed U.MAMADAMINOV detailed J. KIM checked T. JANOF SYLBOLS & ABBREVIATIONS project contract I CONTRACT drawing rev. -701 1 sheet 1 of 5 sheets file E701.DWG D C FBI C IF J no.I date I by I ckd I description SPECIFICATIONS 1 111/04/161 JJJ I KWL I ISSUED FOR PERMIT SECTION 260100 - GENERAL PROVISIONS PROVIDE COMPLETE AND FULLY OPERATIONAL ALL ELECTRICAL SYSTEMS WITHIN THE PROJECT AREA, ALONG WITH POWER CONNECTIONS TO EQUIPMENT FURNISHED UNDER OTHER DIVISIONS OF THE SPECIFICATIONS. A. CODES: CONFORM TO THE NATIONAL ELECTRICAL CODE AND ALL OTHER CODES AND REGULATIONS AS ADOPTED AND AMENDED BY THE STATE OF WASHINGTON AND CITY OF SEATTLE INCLUDING THE AMERICANS WITH DISABILITIES ACT (ADA). B. PERMITS AND FEES: CONTRACTOR TO OBTAIN AND PAY FOR ALL REQUIRED LICENSES, PERMITS AND INSPECTIONS. C. COORDINATION: CONTRACTOR TO COORDINATE ELECTRICAL WORK WITH OTHER TRADES. D. WARRANTY: PROVIDE WARRANTY FOR ONE FULL YEAR AFTER COMPLETION. E. CONTRACT DRAWINGS: RACEWAYS AND OUTLET BOXES ARE SHOWN DIAGRAMMATICALLY ONLY AND THE LAYOUT DOES NOT NECESSARILY SHOW THE TOTAL NUMBER OF RACEWAYS NOR THEIR EXACT LOCATION. THE CONTRACTOR SHALL PROVIDE ALL RACEWAYS, BOXES, CABLES, AND OTHER MATERIALS REQUIRED FOR THE COMPLETE ELECTRICAL SYSTEMS SHOWN OR INDICATED ON THE CONTRACT DRAWINGS. F. RECORD DRAWINGS: AT THE CONCLUSION OF CONTACT WORK, PROVIDE THE OWNER WITH A COMPLETE SET OF REPRODUCIBLE DRAWINGS WITH ALL CHANGES CLEARLY AND LEGIBLY MARKED TO REFLECT THE AS -BUILT CONDITIONS. THESE DRAWINGS SHALL BE LABELED "AS -BUILT" AND CERTIFIED BY THE CONTRACTOR FOR ACCURACY. G. MAINTENANCE MANUALS: COMPLETE FOR EVERY SYSTEM. HARDBOARD COVERS WITH 3 RING BINDERS. H. QUALITY ASSURANCE: 1. MATERIALS AND SYSTEMS: PROVIDE UL LISTED AND LABELED MATERIALS WHERE LISTING SERVICE IS NORMALLY PROVIDED FOR A GIVEN PRODUCT. PROVIDE NEW AND SHIP TO JOBSITE IN ORIGINAL MANUFACTURER'S CONTAINERS OR BUNDLES. 2. WORKMANSHIP: ARRANGE WORK TO OBTAIN COORDINATED INSTALLATION. 3. DRAWINGS: FOR PURPOSE OF CLARITY AND LEGIBILITY, THE DRAWINGS ARE ESSENTIALLY DIAGRAMMATICAL ONLY. 4. ROUTING: EXACT ROUTING OF WIRING AND LOCATIONS OF OUTLETS, PANELS, ETC. SHALL BE GOVERNED BY STRUCTURAL CONDITIONS, OBSTRUCTIONS AND EXISTING CONDITIONS. ARCHITECT RESERVES THE RIGHT AT NO INCREASE IN PRICE, TO MAKE REASONABLE CHANGES IN LOCATIONS OF ELECTRICAL ITEMS EXPOSED AT CEILING AND/OR ON WALLS. COORDINATION: 1. WORK OUT ALL "TIGHT" CONDITIONS INVOLVING WORK UNDER THIS CONTRACT IN ADVANCE OF INSTALLATION. 2. COORDINATE ALL ELECTRICAL POWER AND CONTROL WIRING REQUIREMENTS OF MECHANICAL EQUIPMENT WITH MECHANICAL CONTRACTOR. 3. CONTRACTOR SHALL COORDINATE ALL TENANT -FURNISHED EQUIPMENT LOCATIONS AND CONNECTION REQUIREMENTS WITH TENANT'S VENDOR PRIOR TO ROUGH -IN. CONTRACTOR SHALL MAKE ALL FINAL UNE VOLTAGE CONNECTIONS TO EQUIPMENT AS REQUIRED. 4. CONFIRM ALL ELECTRICAL EQUIPMENT AND SYSTEM PROGRAMMING NOMENCLATURE REQUIREMENTS WITH -IN. CONFORM TO ALL NAMING CONVENTIONS DEFINED THE OWNER PRIOR TO SUBMITTALS AND ROUGH THROUGHOUT THE PROJECT. SECTION 260126 - TESTING A. FURNISH ALL LABOR AND TEST EQUIPMENT AS REQUIRED UNDER THIS SECTION. B. FACILITIES ENGINEERING REPRESENTATIVE NEEDS TO BE PRESENT FOR FINAL TESTING. C. TEST ALL PANELS AND/OR BRANCH CIRCUITS FOR GROUNDS OR SHORTS. REPAIR DEFECTIVE WIRING AS REQUIRED. TEST EACH INDIVIDUAL CIRCUIT AT PANEL FOR PROPER OPERATION. D. AT COMPLETION OF WORK, PROVIDE WRITTEN CERTIFICATION THAT ALL SYSTEMS ARE FUNCTIONING PROPERLY WITHOUT DEFECTS. SECTION 260500 - BASIC MATERIALS AND METHODS INCLUDES GENERAL REQUIREMENTS FOR MATERIALS AND INSTALLATION METHODS, CUTTING BUILDING CONSTRUCTION, PAINTING, CLEAN-UP, AND WORKMANSHIP. A. MATERIALS: ALL MATERIALS SHALL BE NEW FREE FROM DEFECTS, AND SHALL HAVE BEEN TESTED AND LISTED BY UNDERWRITERS LABORATORIES OR OTHER APPROVED TESTING ORGANIZATION AND SHALL BE SO LABELED. B. SUBSTITUTIONS: SHALL BE REVIEWED BY THE ENGINEER. C. WORKMANSHIP: SHALL BE OF THE BEST QUALITY AND PERFORMED BY EXPERIENCED ELECTRICIANS UNDER SUPERVISION OF AN EXPERIENCED FOREMAN. D. NOISE TRANSMISSION: TO PREVENT NOISE TRANSMISSION (IN NEW CONSTRUCTION) BETWEEN ADJOINING ROOMS, ALL DEVICES ON OPPOSITE SIDES OF WALL TO BE SPACE A MINIMUM OF 6" APART (HORIZONTALLY PREFERRED). E. BRANCH CIRCUITING: NO MORE THAN SIX CURRENT CARRYING CONDUCTORS IN ANY ONE (1) HOMERUN. F. GROUNDING: PROVIDE SEPARATE GREEN GROUNDING CONDUCTOR IN ALL EQUIPMENT AND RECEPTACLE BRANCH CIRCUITS. SIZE PER NEC. G. SUBMITTALS: AFTER AWARD OF CONTRACT, SUBMIT THREE COMMON BOUND BROCHURES TO ENGINEER (ONE COPY RETURNED TO CONTRACTOR) CONTAINING CATALOG CUTS AND/OR SHOP DRAWINGS FOR THE FOLLOWING ITEMS: H. CUTTING AND PATCHING: DO NOT CUT STRUCTURAL MEMBERS. ALL CONSTRUCTION MATERIALS DAMAGED OR CUT INTO DURING THE INSTALLATION OF THIS WORK MUST BE REPAIRED OR REPLACED WITH MATERIALS BY SKILLED LABOR EXPERIENCED IN THAT PARTICULAR BUILDING TRADE. 1. PAINTING: TOUCH-UP TO MATCH FACTORY PAINT ANY ELECTRICAL ITEMS SCRATCHED OR MARRED IN SHIPMENT OR INSTALLATION. J. CLEAN UP: CONTINUALLY REMOVE DEBRIS, CUTTINGS, CRATES, CARTONS, ETC. CAREFULLY CLEAN WIRING DEVICES, COVER PLATES, LIGHT FIXTURES, ETC., TO REMOVE PAINT AND PLASTER, ETC. SECTION 260510 - EXISTING SYSTEMS A. EXISTING SYSTEMS AND SYSTEMS ADJACENT TO THE WORK SHALL BE INVESTIGATED THOROUGHLY. ANY DAMAGE RESULTING FROM PERFORMANCE OF WORK UNDER THIS CONTRACT SHALL BE REPAIRED TO ASSURE CONTINUING OPERATION AND INTEGRITY DURING AND AT COMPLETION OF THE PROJECT AT NO INCREASE IN CONTRACT COST. ANY EXISTING WIRING SERVING DEVICES TO REMAIN IN SERVICE AND WHICH IS INTERRUPTED BY WORK PERFORMED UNDER THIS CONTRACT SHALL BE REROUTED TO MAINTAIN CIRCUIT CONTINUITY. CONTRACTOR SHALL ASSUME THE RISK OF MAINTAINING EXISTING SYSTEMS EXCEPT RELOCATION OF WIRING OF #2 AWG AND ABOVE SHALL BE CONSIDERED AN ADDITIONAL COST IF NOT SHOWN TO BE RELOCATED. IF SUCH WIRING IS FOUND THE CONTRACTOR SHALL NOTIFY ENGINEER OF WIRING LOCATION, REASON IT MUST BE REMOVED AND COST OF RELOCATION AND RECEIVE THE OWNER'S APPROVAL BEFORE PROCEEDING WITH THE WORK. THE BUILDING WILL CONTINUE OPERATION DURING THE WORK AND IT IS ESSENTIAL THAT NO SYSTEMS OPERATION BE INTERRUPTED UNLESS SCHEDULED WITH THE OWNER. CONTRACTOR SHALL ASSUME RESPONSIBILITY FOR UNSCHEDULED INTERRUPTIONS AND EXPEDIENT REPAIR. B. ALL CEILING AREAS IN PROJECT AREA. VERIFY THAT EXISTING RACEWAY SUPPORT SYSTEM FOR ALL EXISTING TO REMAIN RACEWAYS ABOVE EXISTING OR NEW ACCESSIBLE CEILINGS IS INSTALLED PER CODE. ADD NEW SUPPORTS AS NECESSARY. C. EXISTING SYSTEMS CONCEALED 1. THE ELECTRICAL DRAWINGS SHOW PORTIONS OF THE EXISTING ELECTRICAL SYSTEMS WHICH ARE TO REMAIN, BE REMOVED OR BE MODIFIED AS A PART OF THE CONTRACTOR'S WORK. CONCEALED FEATURES OF THE EXISTING SYSTEMS ARE DERIVED FROM RECORD DRAWINGS AND THE ENGINEER'S BEST JUDGMENT OF THE CONFIGURATION, BUT NO GUARANTEE IS MADE AS TO THEIR CORRECTNESS. 2. THE CONTRACTOR SHALL INSPECT THE EXISTING INSTALLATION PRIOR TO BIDDING AND SHALL MAKE HIS OWN JUDGMENT AS TO THE WORK REQUIRED TO PROVIDE A COMPLETE INSTALLATION AND DEMOU11ON WITHIN THE INTENT OF THE CONTRACT DOCUMENTS. D. EXISTING SYSTEM DRAWINGS THE DRAWINGS SHOW PORTIONS OF THE EXISTING SYSTEMS WHICH ARE DERIVED FROM RECORD DRAWINGS. THE DRAWINGS ARE INCOMPLETE AND NO GUARANTEE IS MADE TO THEIR CORRECTNESS. THE CONTRACTOR SHALL ASSUME THERE IS 20% MORE ELECTRICAL SYSTEMS THAN SHOWN ON THE DEMOLITION AND EXISTING SYSTEM DRAWINGS. E. DEMOLITION WORK ALL DEMOLITION WORK REQUIRED UNDER THIS CONTRACT IS NOT SHOWN ON THE DRAWINGS. THE CONTRACTOR SHALL REMOVE ALL ELECTRICAL EQUIPMENT IN THE AREA BEING REMODELED WHICH IS NO LONGER IN SERVICE PRESENTLY OR AS A RESULT OF THIS CONTRACT. THE DEFINITION OF ELECTRICAL EQUIPMENT IS ANY EQUIPMENT MENTIONED IN THE NATIONAL ELECTRICAL CODE. F. TEMPORARY ELECTRICAL EQUIPMENT REMOVING, TEMPORARY HANGING BY CHAINS AND REINSTALLING IN CEILINGS OF LIGHT FIXTURES, SPEAKERS, DETECTORS, EXIT SIGNS AND OTHER ELECTRICAL EQUIPMENT IS NOT SHOWN ON THE DRAWINGS. THE CONTRACTOR SHALL INVESTIGATE THE CEILING DEMOLITION WORK AND INCLUDE THIS WORK IN THE BID. THE SEQUENCE OF WORK SHALL BE (1) REMOVE AND STORE FIXTURES, DETECTORS AND SPEAKERS ALONG WITH REMOVAL OF CEILING, (2) PROVIDE TEMPORARY SUPPORT FOR WIRED FIXTURES AND DEVICES TO BE REINSTALLED IN NEW CEILING AT APPROXIMATELY THE SAME LOCATION. USE CHAINS FOR LIGHTING FIXTURE SUPPORT, (3) CLEAN AND REINSTALL 1N THE NEW OR REPLACED CEILINGS, PROVIDE NEW LAMPS WHEN SO NOTED. PROVIDE TEMPORARY RELOCATION OF EXIT SIGNS CONNECTED TO EXISTING EMERGENCY CIRCUITS AND REINSTALL IN THE ORIGINAL LOCATION WHEN EXIT IS REACTIVATED. G. PREMIUM TIME PREMIUM TIME SHALL BE INCLUDED IN THE BASE BID FOR ELECTRICAL SYSTEM(S) OUTAGES AND FOR OTHER WORK AS REQUIRED BY THE SCHEDULE, AS SHOWN ON THE DRAWINGS AND AS NOTED IN OTHER DIVISIONS OF THE SPECIFICATIONS. H. WORK OUTSIDE OF REMODEL AREAS CAUTION - THIS WORK IS NOT SHOWN ON THE CONTRACT DOCUMENTS. PROVIDE NEW WIRING SYSTEMS IN CONCEALED CEILING SPACES TO SWITCHBOARDS, PANELBOARDS, COMMUNICATION AND SIGNALING AND SYSTEM CONTROL PANELS. PROVIDE NEW CONDUIT SYSTEMS IN CEILING SPACES OF FLOOR BELOW REMODEL FLOORS. REMOVE AND RELOCATE ELECTRICAL EQUIPMENT IN THE WAY OF OTHER TRADES WORK INSTALLED UNDER THIS CONTRACT. SPACES ABOVE EXISTING CEILINGS ARE HIGHLY CONGESTED. ROUTE WIRING AROUND OBSTRUCTIONS AND PROVIDE PULL BOXES PER CODE. I. EXISTING MATERIALS ALL MATERIALS WHICH ARE A PART OF THE BUILDING SHALL REMAIN THE PROPERTY OF THE OWNER. J. EXISTING MATERIALS TO BE REINSTALLED EXISTING MATERIALS AND EQUIPMENT (EXCEPT INTERIOR, UNDAMAGED RACEWAYS) THAT ARE REMOVED AS A PART OF THE WORK OR STORED IN SURPLUS SHALL NOT BE REINSTALLED AS A PART OF THE NEW SYSTEMS UNLESS SPECIFICALLY NOTED OR AUTHORIZED IN WRITING BY THE OWNER. FORWARD A COPY OF THE AUTHORIZATION TO THE ENGINEER. THE REQUIREMENTS OF THE SPECIFICATIONS (I.E., CONDITION, INSTALLATION, TESTING, ETC.) SHALL APPLY AS IF THE MATERIALS WERE NEW, FURNISHED BY THE CONTRACTOR. K. EXISTING MATERIALS NOT TO BE REINSTALLED ALL MATERIAL TO BE DEMOLISHED AND DEBRIS SHALL BE LEGALLY DISPOSED OF BY THE CONTRACTOR. L EXISTING RACEWAYS THE CONTRACTOR MAY REUSE THE EXISTING RACEWAYS IF NO OTHER SYSTEMS OCCUPY THE RACEWAY, RACEWAYS AND ENCLOSURES ARE ELECTRICALLY AND MECHANICALLY CONTINUOUS AND NEW WIRING IS PROVIDED. NO WARRANTY IS MADE AND THE CONTRACTOR SHALL ASSUME THE RISK OF USING EXISTING OUTLET BOXES AND RACEWAY SYSTEMS. M. EXISTING CONDITIONS EXAMINE THE STRUCTURE, BUILDING, AND CONDITIONS UNDER WHICH ELECTRICAL WORK IS TO BE INSTALLED FOR CONDITIONS DETRIMENTAL TO PROPER AND TIMELY COMPLETION OF ELECTRICAL WORK. DO NOT PROCEED WITH WORK UNTIL DEFICIENCIES OR DETRIMENTAL CONDITIONS HAVE BEEN CORRECTED. REPORT DEFICIENCIES OR DETRIMENTAL CONDITIONS OF EXISTING ELECTRICAL WORK WHICH MIGHT BE UNSUITABLE TO CONNECT WITH OR RECEIVE OTHER WORK. FAILURE TO SO REPORT SHALL CONSTITUTE ACCEPTANCE OF OTHER WORK AS BEING FIT AND PROPER FOR THE RECEPTION OF ELECTRICAL WORK. N. EXISTING SYSTEMS MAINTAINED GENERAL REROUTE EXISTING CIRCUITS THAT ARE INTERRUPTED AS A RESULT OF THIS CONTRACT THAT SERVE DEVICES TO REMAIN IN SERVICE. 1. POWER CIRCUITS TRACE OUT AND IDENTIFY LOADS AND SYSTEMS BEING SERVED. PROVIDE TEMPORARY WIRING, SCHEDULE OUTAGE AND RECONNECT LOADS TO TEMPORARY WIRING. PROVIDE NEW WIRING IN NEW LOCATION. SCHEDULE OUTAGE, DISCONNECT TEMPORARY WIRING, AND CONNECT LOADS TO NEW WIRING. 2. SIGNAL AND COMMUNICATION SYSTEMS TRACE OUT AND IDENTIFY DEVICE AND SYSTEMS BEING SERVED. PROVIDE TEMPORARY WIRING TO MAINTAIN OPERATION OF SYSTEM THROUGHOUT FACILITY. SCHEDULE OUTAGE AND CONNECT TO TEMPORARY WIRING AND TEST SYSTEM. PROVIDE NEW WIRING AND NEW EQUIPMENT IN PROJECT AREA. SCHEDULE OUTAGE, DISCONNECT TEMPORARY WIRING AND CONNECT NEW WIRING AND NEW EQUIPMENT AND TEST SYSTEM. 0. DEMOLITION SIGNALING AND COMMUNICATION SYSTEMS, LIGHTING FIXTURES, OTHER ELECTRICAL EQUIPMENT FREE STANDING OR SURFACE MOUNTED, RACEWAY (EXPOSED) AND CONDUCTORS; WHICH ARE NO LONGER IN SERVICE PRESENTLY OR AS A RESULT OF THIS CONTRACT SHALL BE REMOVED. UNUSED FLUSH MOUNTED DEVICES, OUTLET AND OTHER BOXES IN FINISHED AREAS SHALL BE REMOVED FROM WALL AND THE REMAINING HOLE PATCHED TO MATCH ADJACENT WALL SURFACES. UNUSED RACEWAYS AND SLEEVES EMBEDDED IN CONCRETE SHALL BE CUT FLUSH AT CEILING, FLOOR OR WALL AND FILLED WITH GROUT. ALL UNUSED RACEWAYS ABOVE CEILINGS SHALL BE REMOVED. CONTRACTOR SHALL REMOVE ALL FLOOR, WALL OR CEILING MOUNTED ELECTRICAL EQUIPMENT IN THE "DEMOLITION AREA" INDICATED ON THE DRAWINGS EVEN IF THE EQUIPMENT/OR DEVICE IS NOT SHOWN ON THE PROJECT DRAWINGS. IF CONTRACTOR QUESTIONS WHETHER A PARTICULAR DEVICE IS TO BE REMOVED NOTIFY THE ENGINEER NOTING TYPE AND LOCATION OF DEVICE. IF SO DIRECTED THE CONTRACTOR SHALL MAINTAIN THE EXISTING DEVICE IN SERVICE WITHOUT ANY CHANGE IN CONTRACT PRICE. P. POWER OUTAGES 1. SCHEDULED OUTAGES. THE EXISTING FACILITY WILL CONTINUE ITS NORMAL OPERATION DURING THE CONSTRUCTION WORK; THEREFORE IT IS REQUIRED THAT THE CONTRACTOR SCHEDULE ELECTRICAL SYSTEM(S) OUTAGES WITH THE OWNER OR BUILDING MANAGEMENT. SUBMIT A WRITTEN REQUEST FOR A POWER OUTAGE AT LEAST ONE WEEK IN ADVANCE IDENTIFYING THE AREAS, AND SYSTEMS THAT WILL BE AFFECTED, TIME AND DURATION OF THE POWER OUTAGE. THE CONTRACTOR SHALL RECEIVE WRITTEN AUTHORIZATION TO PROCEED WITH THE OUTAGE AND SHALL RE -NOTIFY THE OWNER OR BUILDING MANAGEMENT VERBALLY AT LEAST ONE HOUR PRIOR TO THE OUTAGE AND ALSO N011FY THE OWNER WHEN THE OUTAGE IS COMPLETED. 2. UNSCHEDULED OUTAGES, IN THE EVENT THAT THE CONTRACTOR'S WORK CAUSES OR CONTRIBUTES TO AN UNSCHEDULED SYSTEM(S) OUTAGE (OR OTHER SYSTEM FAULT), THE CONTRACTOR IS RESPONSIBLE FOR IMMEDIATELY CORRECTING THE PROBLEM. INCLUDED (AS EXAMPLES) SHALL BE ANY PREMIUM TIME REQUIRED TO STAY ON TFE JOB SITE UNTIL PROBLEM IS CORRECTED AND AIR FREIGHT FOR PARTS NOT LOCALLY AVAILABLE. Q. ACCESS TO PERFORM WORK CAREFULLY REMOVE, STORE OR TEMPORARILY HANG AND RE -INSTALL IN UNDAMAGED CONDITION ALL ELECTRICAL EQUIPMENT, LGHTING FIXTURES AND CEILING 11LES WHERE ACCESS TO PERFORM WORK IS REQUIRED. CLEAN PRIOR 10 RE -INSTALLATION. R. NEW DEVICES IN REMODEL AREAS PROVIDE FLUSH MOUNTING FOR DEVICES IN EXISTING WALLS. FISH CONDUIT IN WALL WHERE EXISTING BOXES ARE INDICATED TO BE REUSED, EXTEND BOX AS NECESSARY AND PROVIDE NEW DEVICES AND PLATES. CONTRACTOR IS CAUTIONED THAT THE EXISTING BUILDING CONTAINS CLAY TILE AND CONCRETE WALLS. NEW DEVICES MAY REQU',RE CUTTING, PATCHING, AND PAINTING OF WALLS AND IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO PROVIDE ALL CUTTING, PATCHING AND PAINTING REQUIRED FOR THE INSTALLATION OF THE DIVISION 16 WORK. CONTRACTOR SHALL INVESTIGATE EXISTING AREAS PRIOR TO BID AND SHALL INCLUDE ALL COSTS OF SUCH WORK IN THE BID. THIS FACILITY HAS WIRING EMBEDDED IN RACEWAYS IN CONCRETE SLABS. PROVIDE NEW CONCEALED WIRING TO LAST OUTLET OR PULL BOX BEFORE HOMERUN TO PANEL. SECTION 260519 - LOW VOLTAGE ELECTRICAL POWER CONDUCTORS AND CABLES A. PROVIDE ALL WIRE AND CABLE COMPLETE. COPPER, INSULATED FOR 60OV. ALUMINUM OR COPPER CLAD ALUMINUM CONDUCTORS NOT PERMITTED. TYPE THW, THWN/THHN OR XHHW. NUMBER 12 AWG MINIMUM FOR POWER AND LIGHTING CIRCUITS. B. SPLICES: SOLDERLESS TYPE ONLY. PRE -INSULATED "TWIST -ON" TYPE (LIMITED TO SIZE #10 AND SMALLER). BOLT OR COMPRESSION .SET T)PE WITH APPLICATION OF PREFORMED INSULATED COVER, HEAT SHRINKABLE TUBING OR PLASTIC INSULATED TAPE ACCEPTABLE FOR ALL SIZES. C. TERMINATIONS: COMPRESSION SET, BOLTED OR SCREW TERMINAL CONDUCTORS #12 AND SMALLER SHALL UTILIZE EYE OR FORKED TONGUE TYPE COMPRESSION SET TERMINATOR WHEN TERMINATION IS TO A BOLTED SCREW SET TYPE TERMINAL BLOCK OR TERMINAL CABINET. D. COLOR CODE: 480 MARKING BRN, ORG, YELL, GRAY NEUTRAL 208 MARKING BLK, RED, BLU, WHITE NEUTRAL E. BRANCH CIRCUITS: COPPER. SOLID FOR NO.10 AWG AND SMALLER; STRANDED FOR NO.8 AWG AND LARGER. F. MULTICONDUCTOR CABLE IS PERMITTED ONLY AS DETAILED IN THE DRAWINGS. COMPLY WITH NEMA WC 70 FOR ARMORED CABLE, TYPE AC METAL -CLAD CABLE, TYPE MC AND TYPE SO WITH GROUND WIRE. G. ALL 480/277V WIRING WILL BE SEPARATED FROM THE 208/120V WIRING AT ALL TIMES. EXCEPTIONS: MOTOR CONTROLS. SECTION 260526 - GROUNDING PROVIDE A GROUNDING SYSTEM FOR EQUIPMENT AND DEVICE GROUND AS REQUIRED BY CODE. A. ALL NEW AND EXISTING RECEPTACLES TO HAVE GROUNDED POLES. SECTION 260533 - RACEWAYS AND BOXES A. PROVIDE RACEWAY SYSTEM COMPLETE AND IN CONFORMANCE WITH CODE. INSTALL RACEWAYS CONCEALED IN CONSTRUCTON FOR ALL AREAS UNLESS EXPOSED RACEWAYS ARE SPECIFICALLY SHOWN. B. PROVIDE 1" RACEWAY FOR HOMERUNS AND MAJOR CEILING CONDUIT RUNS. RACEWAY DROPS DOWN WALLS AND RACEWAY CARRYING 2 CURRENT CARRYING CONDUCTORS CAN BE 3/4". MINIMUM RACEWAY SIZE IS 3/4". C. PROVIDE PULLWMRE IN ALL EMPTY RACEWAYS. D. INTERIOR RACEWAYS: ELECTRICAL METALLIC TUBING (EMT) WITH STEEL COMPRESSION OR SET SCREW FITTINGS. INDENTOR, DRIVE -ON AND PRESSURE CAST ON DIE CAST TYPE SET SCREW FITTINGS ARE NOT ACCEPTABLE. E. RACEWAY PENETRATIONS: PENETRATIONS THROUGH FIRE RATED CONSTRUCTION SHALL BE SEALED USING 3M FIRE BARRIER CAULK, NELSON ELECTRIC FLAMESEAL OR T & B FLAMESAFE OR USE OTHER METHOD APPROVED BY THE ARCHITECT. F. PROVIDE AND SIZE OU -LET BOXES FOR DEVICES SUCH AS RECEPTACLES, SWITCHES AND LIGHT FIXTURES AND PULL BOXES AS REQUIRED IN THE CONDUIT SYSTEM PER THE NATIONAL ELECTRICAL CODE. CONTRACTOR SHALL COORDINATE WITH GENERAL CONTRACTOR TO DETERMINE ANY SPECIALTY INSTALLATION REQUIREMENTS DUE TO FIRE RATINGS, CORE WALLS, ETC. G. INTERIOR WIRING: PRESSED STEEL, ZINC COATED WITH PLASTER RING WHERE APPLICABLE. MOUNT OUTLET BOXES FOR RECEPtACLES AND OTHER DEVICES AT 18", UNLESS OTHERWISE NOTED. C. RECEPTACLES: 208V SINGLE PHASE RECEPTACLES: PROVIDE NEMA TYPE RECEPTACLES AS INDICATED ON DRAWINGS. DEVICES SHALL BE UL LISTED. PROVIDE DEVICES FROM ACCEPTABLE MANUFACTURERS; HUBBELL, LEVITON, PASS & SEYMOUR. GROUND FAULT CIRCUIT INTERRUPTER (GFCI) RECEPTACLE: SPECIFICATION GRADE, NEMA 5-15R CONFIGURATION, DUPLEX RECEPTACLE WITH 4-6 MILLIAMPS LEAKAGE CURRENT TRIP LEVEL FEED THROUGH TYPE TO PROTECT DOWNS -REAM RECEPTACLES ON THE SAME CIRCUIT. HUBBELL GFR5352L, LEVITON 7590 OR PASS & SEYMOUR 2095. COMBINATION GROUND FAULT CIRCUIT INTERRUPTER (GFCI) / SAFETY RECEPTACLE: COMBINATION U.L LISTED GFCI AND TAMPER RESISTANT RECEPTACLE, AUTOMATIC MECHANICAL SHUTTER TO PREVENT OBJECTS FROM BEING INSERTED INTO RECEPTACLES. PASS & SEYMOUR 2095TR, HUBBELL GFTR20. D. INTERIOR DEVICE PLATES: STAINLESS STEEL WITH 302 SATIN FINISH. E. IDENTIFICATION: EMERGENCY RECEPTACLES DEVICE PLATES SHALL BE LABELED WITH "EMERGENCY" ABOVE THE RECEPTACLE IN 3/16" HIGH RED FILLED LETTERS ALSO LABELED BELOW THE RECEPTACLE THE PANELBOARD AND CIRCUIT NUMBER SERVING THE RECEPTACLE. NORMAL RECEPTACLE DEVICE PLATES SHALL BE LABELED BELOW WITH PANELBOARDS AND CIRCUIT NUMBER (BLACK FILLED LETTERS). RECEPTACLE COVERPLATES FOR RECEPTACLES OTHER THAN 15 AND 20 AMP SHALL BE LABELED WITH AMPERE RATING, VOLTAGE AND PHASE. UTILIZE MACHINE PRINTED ADHESIVE FILM LABELS BY THERMAL TRANSFER OR EQUIVALENT PROCESS. F. PROVIDE A GFCI RECEPTACLE WITHIN 5'-0" OF ALL WATER SOURCES. ���II�P►i►�:��:3I��I1�d�1�1i+1��lI,YPI�l11�'ix�)�y;'J<t�1:1�� A. PROVIDE STANDARD DUTY TYPE DISCONNECT SWITCHES FOR EQUIPMENT, SIZED PER CODE. EQUIPMENT SIZING SHOWN ON DRAWINGS SHALL BE CONFIRMED AND REVISED AS REQUIRED TO MEET NEC. B. FUSES TO BE SIZED AS DIRECTED BY MECHANICAL EQUIPMENT MANUFACTURER. C. WEATHER PROOF SWITCHES NOTED "WP" TO BE NEMA 3R LISTED EQUIPMENT. D. IDENTIFICA11ON: PROVIDE ENGRAVED PHENOLIC NAMEPLATE FOR ALL DISCONNECTS. FOR EQUIPMENT CONNECTED TO EMERGENCY PROVIDE 3/16" HIGH WHITE FILLED LETTERS ON RED BACKGROUND IDENTIFYING EQUIPMENT SERVED AND THE PANELBOARD AND CIRCUIT NUMBER SERVING THE EQUIPMENT. FOR EQUIPMENT CONNECTED TO NORMAL PROVIDE 3/16" HIGH WHITE FILLED LETTERS ON BLACK BACKGROUND IDENTIFYING EQUIPMENT SERVED AND THE PANELBOARD AND CIRCUIT NUMBER SERVING THE EQUIPMENT SECTION 270533 - CONDUITS AND BACKBOXES FOR COMMUNICATIONS SYSTEMS PROVIDE OUTLET BOXES AND RACEWAYS READY FOR THE INSTALLATION OF COMMUNICATION CABLES BY OWNER. A. OUTLET BOXES: 4" SQUARE, 2" DEEP WITH SINGLE DEVICE PLASTER RING. B. COVERPLATES: BY OWNER. C. RACEWAYS: 3/4" FOR UP TO 4 CABLES, 1" FOR UP TO 6 CABLES WITH PLASTIC BUSHING ON ALL RACEWAY ENDS. ROUTE RACEWAY TO ABOVE ACCESSIBLE CEILING SPACE. CONFIRM AT BIDDING PERIOD ALL ROUTING REQUIREMENTS WITH OWNER FOR RACEWAY QUANTITIES AT BIDDING. PROVIDE PULL -STRING. E. IDENTIFICATION LABELS COMPLY WITH TTA/EIA-606-A AND APPLICABLE REQUIREMENTS IN THIS SECTION. MACHINE PRINTED SELF-ADHESIVE, SMUDGE RESISTANT LABELS FOR CABLES AND FACE -PLATES. LABELS SHALL BE APPROPRIATELY SIZED FOR CABLE DIAMETER. LABELS SHALL BE APPROPRIATELY COLORED FOR FACE -PLATE COLOR CONTRAST. SUBMIT SAMPLE LABELS FOR APPROVAL F. FOLLOW MANUFACTURERS' INSTRUCTIONS FOR INSTALLING COMPONENTS AND ADJUSTING ALL EQUIPMENT AND TELECOMMUNICATIONS CABLES. WHERE NO INSTRUCTIONS ARE INCLUDED WITH THE EQUIPMENT, FOLLOW ACCEPTED INDUSTRY PRACTICES AND WORKMANLIKE INSTALLATION STANDARDS. G. KEEP ALL ITEMS PROTECTED BEFORE AND AFTER INSTALLATION, WITH DUST AND WATER PROOF BARRIER MATERIALS AS NECESSARY. THE CONTRACTOR SHALL BE RESPONSIBLE TO ENSURE THE INTEGRITY OF THE PROTECTIVE MEASURES THROUGHOUT THE LIFE OF THE PROJECT. H. COMPLY WITH BICSI TCI, TIA/EIA-568-B.1, TIZ/EIA-568-B.2, TTA/EIA-568-8.3, AND TIA/EIA-569-A. I. 4 -PAIR UTP CABLE INSTALLATION PROVIDE 4 -PAIR UTP CABLES FROM THE IDF ROOMS TO THE COMMUNICATION OUTLETS AS SHOWN ON THE DRAWINGS. TERMINATE THE CABLES ONTO 8 -PIN MODULAR PANELS IN THE IDF AND ONTO 8 -PIN MODULAR CONNECTORS AT THE OUTLET LOCATION. ROUTE THE CABLES IN THE ACCESSIBLE CEILING AREA. SUPPORT THE CABLES WITH J -HOOKS INSTALLED AT A MAXIMUM SEPARATION OF 48 -INCHES IN ROUTE BACK TO THE CABLE TRAYS. DO NOT ALLOW UTP CABLES TO RUN PARALLEL WITH' ELECTRICAL CABLES/CONDUITS, UNLESS THEY ARE SEPARATED BY A MINIMUM OF 12 INCHES. ANY TELECOMMUNICATIONS CABLES THAT MUST CROSS OVER ELECTRICAL CABLES/CONDUITS SHALL DO SO ONLY AT 90 -DEGREE ANGLES. J. PROVIDE CATEGORY 6 8 -PIN MODULAR CONNECTORS FOR THE TERMINATION OF ALL 4 -PAIR CABLES. PROVIDE AN ACCOMPANYING FACEPLATE AND/OR MOUNTING PLATE AT THE APPROPRIATE OUTLET LOCATION. INSTALL FACEPLATES LEVEL AND ALIGN TO ADJACENT OUTLET FACEPLATES. K. IDENTIFICATION PROVIDE ON ALL OUTLET FACEPLATES INSTALLED UNDER THIS WORK, MACHINE -GENERATED LABELS WITH THE OUTLET ID, IN UPPERCASE LETTERING. LABEL SHALL BE OF A CONTRASTING COLOR TO THE FACEPLATE COLOR. PROVIDE ON ALL TERMINATION BLOCKS INSTALLED UNDER THIS WORK, MACHINE -GENERATED DESIGNATION STRIPS WITH THE CABLE ID AND PAIR NUMBER, IN UPPERCASE LETTERING. RECEIVED CITY OF Tt KWiLA DEC 15 2016 PERMIT CENTER Name Discipline License No. 4100 194th Street SW Suite 400 Lynnwood Washington 98036-4613 (206) 667-0555 11/04/16 designed U.MAMADAMINOV detailed J. KIM checked T. JANOF SYLBOLS & ABBREVIATIONS project contract I CONTRACT drawing rev. -701 1 sheet 1 of 5 sheets file E701.DWG D C FBI C IF J P E c E U Li.. U U) 0 z <c 0 Q x m 0 N 0 'o z w i M 0 00 01>00 0 C14 i 0 i 2 3 4 5 6 7 8 1 9 10 11 12 13 14 ELECTRICAL RISER EQUIPMENT o EQUIPMENT CABINET ® ®E EQUIPMENT CONNECTION, E = EMERGENCY POWER Tr T -r GROUND BAR, LENGTH TO SCALE <>, MOTOR CONNECTION, SINGLE PHASE ,(De MOTOR CONNECTION, 3 PHASE POWER BUSWAY SPD 1 SURGE PROTECTIVE DEVICE QT TRANSFORMER, <30KVA, NOT TO SCALE 0 TRANSFORMER, 30KVA OR GREATER, DRAWN TO SCALE CIRCUITS —I� RACEWAY CONCEALED IN CEILING OR WALL HASH MARKS INDICATE NUMBER OF WIRES. #12 AWG WIRE UNLESS OTHERWISE NOTED. EXPOSED RACEWAY IS ALLOWED ONLY WHERE NOTED. —�— HOT (SHORT HASH MARK) ---F— NEUTRAL (LONG HASH MARK) —f— GROUND WIRE (JOGGED HASH MARK) EXISTING RACEWAY (IF HASH MARKS ARE SHOWN, PULL NEW CONDUCTORS) - - - - - RACEWAY BELOW SLAB OR UNDERGROUND —o RACEWAY UP RACEWAY DOWN RACEWAY STUB -OUT WITH BUSHING --2 CIRCUIT CONTINUATION HOME RUN TO PANEL OR LOCATION NOTED Q MJ JUNCTION BOX PB PULL BOX WORK DEFINITION FLAG NOTE ® REVISION IDENTIFICATION # EQUIPMENT IDENTIFICATION # EQUIPMENT IDENTIFICATION Det# DETAIL REFERENCE Sheet# Det# V DETAIL REFERENCE W/ORIGINATING SHEET REFERENCE PlanSheet# DetSheet# �# Sheet# SECTION REFERENCE v Sec# SECTION REFERENCE W/ORIGINATING SHEET REFERENCE PlanSheet# DetSheet# I Elev# ELEVATION REFERENCE Sheet# aPROJECT NORTH REFERENCE TnA loam PROJECT NORTH REFERENCE W/TRUE NORTH REFERENCE NEW WORK EXISTING ----- FUTURE jxxxx REMOVE EXISTING ELECTRICAL EQUIPMENT CONTROLS FUSED DISCONNECT SWITCH (FUSE RATING INDICATED) DISCONNECT SWITCH MOTOR STARTER MANUAL MOTOR STARTER COMBINATION MOTOR STARTER FUSED DISCONNECT SWITCH ENCLOSED CIRCUIT BREAKER © CONTACTOR Q r -.'l PUSH BUTTON CONTROL STATION -1- AUTO DOOR PUSHPLATE EMERGENCY SHUTDOWN M MOTOR RATED TOGGLE SWITCH BUSWAY PLUG FD_D_C_1 DIRECT DIGITAL CONTROL PANEL 0 RELAY, CONTROL TYPE OT THERMOSTAT TC TIME CLOCK FVFD_1 VARIABLE FREQUENCY DRIVE CIRCUITS LIGHTING EMERGENCY NORMAL 4nq WALL MOUNTED FIXTURE PANELBOARDS drm 208V SYSTEM PAWLBOARD 9:9 480V SYSTEM PANELBOARD LIGHTING SWITCHES AND CONTROLS - a LOWER-CASE I ET -ER NEAR SWITCH DENOTES CIRCUIT CONTROLLED (TYP) SINGLE POLE SWITCH 2 DOUBLE POLE SWITCH 3 3 -WAY SWITCH 4 4 -WAY SWITCH K KEY OPERATED SWITCH LV MOMENTARY CONTACT, LOW VOLTAGE SWITCH e OCCUPANCY SENSOR SWITCH P SWITCH WITH PILOT LIGHT PC PHOTOCELL SWITCH DIMMER SWITCH CS 1 CONTROL STATION, # INDICATES STATION IDENTIFICATION DSC DIMMING SYSTEM CONTROLS ELCU v. EMERGENCY LIGHTNG CONTROL UNIT OS CEILING MOUNTED OCCUPANCY SENSOR SWITCH PC PC PHOTOCELL CONTFOL PS PHOTO SENSOR CONTROL RELAY, NEC CLASS II QT LOW VOLTAGE TRANSFORMER CIRCUITS FEEDER SIZE IDENTIFICATION EMERGENCY AVAILABLE FAULT CURRENT IDENTIFICATION ® a ARRESTOR, SURGE a ARRESTOR, LIGHTNING aAUTOMATIC 0 TRANSFER SWITCH SPACE BUS SPACE AFF BUS DUCT MM BUSWAY END TAP BOX SPLIT WIRED RECEPTACLE, 120V, TOP SWITCHED CABLE TO BUS CONNECTION I CAPACITOR N/A �) CONTACT, NORMALLY OPEN AND NORMALLY CLOSED N/A CIRCUIT BREAKER COMBINATION RECEPTACLE 120/208V OR 120/24OV, SINGLE CIRCUIT BREAKER, DRAWOUT NEUTRAL CIRCUIT BREAKER, DRAWOUT, MEDIUM VOLTAGE GF NIC GF CIRCUIT BREAKER, GA AMERICAN WIRE GAUGE CIRCUIT BREAKER, GF] WITH DRAWOUT d'Z►-� CIRCUIT BREAKER, MAGNETIC OVERLOAD SINGLE RECEPTACLE 120V (TWIST LOCK) CIRCUIT BREAKER, NETWORK PROTECTOR C'1 -''XJ CIRCUIT BREAKER, THERMAL OVERLOAD 8 ®%J'A FUSE OR CURRENT LIMITER PB FUSE (ISOLATING) N/A CLOSED CIRCUIT TELEVISION •`�® FUSED SWITCH -L- GROUND POS PUSHBUTTON a SPLICE Q STRESS RELIEF, MEDIUM VOLTAGE N/A SWITCH, 2 -POLE H N/A A o � SWITCH, 3 -POLE 0 ® r)(:j THERMAL ELEMENT m TRANSFORMER (Q) TRANSFORMER, CURRENT ® TRANSFORMER, ELECTROSTATICALLY SHIELDED, MAGNETIC CORE SHOWN RECEPTACLE ® J r"v-w's TRANSFORMER, MAGNETIC CORE SHOWN ® FLOOR BOX (DEVICES AS INDICATED) N/A TRANSFORMER, SHIELDED, MAGNETIC CORE SHOWN aAMMETER 40 `:J CONTACTOR SINGLEMODE ENGINE -GENERATOR OKEY INTERLOCK O METER GPOWER METER O RELAY DOWN RELAY, GA ® SURGE PROTECTIVE DEVICE OVOLTMETER o WHM WATT HOUR METER EQUIPMENT o EQUIPMENT CABINET ® ®E EQUIPMENT CONNECTION, E = EMERGENCY POWER Tr T -r GROUND BAR, LENGTH TO SCALE <>, MOTOR CONNECTION, SINGLE PHASE ,(De MOTOR CONNECTION, 3 PHASE POWER BUSWAY SPD 1 SURGE PROTECTIVE DEVICE QT TRANSFORMER, <30KVA, NOT TO SCALE 0 TRANSFORMER, 30KVA OR GREATER, DRAWN TO SCALE CIRCUITS —I� RACEWAY CONCEALED IN CEILING OR WALL HASH MARKS INDICATE NUMBER OF WIRES. #12 AWG WIRE UNLESS OTHERWISE NOTED. EXPOSED RACEWAY IS ALLOWED ONLY WHERE NOTED. —�— HOT (SHORT HASH MARK) ---F— NEUTRAL (LONG HASH MARK) —f— GROUND WIRE (JOGGED HASH MARK) EXISTING RACEWAY (IF HASH MARKS ARE SHOWN, PULL NEW CONDUCTORS) - - - - - RACEWAY BELOW SLAB OR UNDERGROUND —o RACEWAY UP RACEWAY DOWN RACEWAY STUB -OUT WITH BUSHING --2 CIRCUIT CONTINUATION HOME RUN TO PANEL OR LOCATION NOTED Q MJ JUNCTION BOX PB PULL BOX WORK DEFINITION FLAG NOTE ® REVISION IDENTIFICATION # EQUIPMENT IDENTIFICATION # EQUIPMENT IDENTIFICATION Det# DETAIL REFERENCE Sheet# Det# V DETAIL REFERENCE W/ORIGINATING SHEET REFERENCE PlanSheet# DetSheet# �# Sheet# SECTION REFERENCE v Sec# SECTION REFERENCE W/ORIGINATING SHEET REFERENCE PlanSheet# DetSheet# I Elev# ELEVATION REFERENCE Sheet# aPROJECT NORTH REFERENCE TnA loam PROJECT NORTH REFERENCE W/TRUE NORTH REFERENCE NEW WORK EXISTING ----- FUTURE jxxxx REMOVE EXISTING ELECTRICAL EQUIPMENT CONTROLS FUSED DISCONNECT SWITCH (FUSE RATING INDICATED) DISCONNECT SWITCH MOTOR STARTER MANUAL MOTOR STARTER COMBINATION MOTOR STARTER FUSED DISCONNECT SWITCH ENCLOSED CIRCUIT BREAKER © CONTACTOR Q r -.'l PUSH BUTTON CONTROL STATION -1- AUTO DOOR PUSHPLATE EMERGENCY SHUTDOWN M MOTOR RATED TOGGLE SWITCH BUSWAY PLUG FD_D_C_1 DIRECT DIGITAL CONTROL PANEL 0 RELAY, CONTROL TYPE OT THERMOSTAT TC TIME CLOCK FVFD_1 VARIABLE FREQUENCY DRIVE CIRCUITS LIGHTING EMERGENCY NORMAL 4nq WALL MOUNTED FIXTURE PANELBOARDS drm 208V SYSTEM PAWLBOARD 9:9 480V SYSTEM PANELBOARD LIGHTING SWITCHES AND CONTROLS - a LOWER-CASE I ET -ER NEAR SWITCH DENOTES CIRCUIT CONTROLLED (TYP) SINGLE POLE SWITCH 2 DOUBLE POLE SWITCH 3 3 -WAY SWITCH 4 4 -WAY SWITCH K KEY OPERATED SWITCH LV MOMENTARY CONTACT, LOW VOLTAGE SWITCH e OCCUPANCY SENSOR SWITCH P SWITCH WITH PILOT LIGHT PC PHOTOCELL SWITCH DIMMER SWITCH CS 1 CONTROL STATION, # INDICATES STATION IDENTIFICATION DSC DIMMING SYSTEM CONTROLS ELCU v. EMERGENCY LIGHTNG CONTROL UNIT OS CEILING MOUNTED OCCUPANCY SENSOR SWITCH PC PC PHOTOCELL CONTFOL PS PHOTO SENSOR CONTROL RELAY, NEC CLASS II QT LOW VOLTAGE TRANSFORMER CIRCUITS RECEPTACLES EMERGENCY NORMAL AC 3" ABOVE COUNTER BACKSPLASH (b SINGLE RECEPTACLE 120V ACH ABOVE COUNTER HEIGHT DUPLEX RECEPTACLE 120V MANHOLE AFF DOUBLE DUPLEX RECEPTACLE 120V MM - SPLIT WIRED RECEPTACLE, 120V, TOP SWITCHED 4b 16 RECEPTACLE 208V OR 240V, SINGLE PHASE N/A 9 RECEPTACLE 208V OR 240V, THREE PHASE N/A 6 COMBINATION RECEPTACLE 120/208V OR 120/24OV, SINGLE N NEUTRAL PHASE N/A NIC RECEPTACLE 480V, SINGLE PHASE N/A AMERICAN WIRE GAUGE RECEPTACLE 48OV, THREE PHASE OPERATER/OPERABLE .(� SINGLE RECEPTACLE 120V (TWIST LOCK) . OWNER PROVIDED OWNER INSTALLED DUPLEX RECEPTACLE 120V (TWIST LOCK) N/A PB RECEPTACLE 208V OR 240V, SINGLE PHASE (TWIST LOCK) N/A CLOSED CIRCUIT TELEVISION RECEPTACLE 208V OR 240V, THREE PHASE (TWIST LOCK) N/A CKT COMBINATION RECEPTACLE 120/208V OR 120/24OV, SINGLE POS POSITION/POINT OF SALE PHASE (TWIST LOCK) N/A PR RECEPTACLE 48OV, SINGLE PHASE (TWIST LOCK) N/A CEILING MOUNTED RECEPTACLE 480V, THREE PHASE (TWIST LOCK) N/A COMM CLOCK RECEPTACLE 120V R ® SINGLE RECEPTACLE, FLUSH FLOOR BOX CONDUIT ® DUPLEX RECEPTACLE, FLUSH FLOOR BOX CO ® DOUBLE DUPLEX RECEPTACLE, FLUSH FLOOR BOX RECEPTACLE ® SPLIT WIRED RECEPTACLE, 120V, FLUSH FLOOR BOX N/A ® FLOOR BOX (DEVICES AS INDICATED) N/A @ POKE THROUGH (DEVICES AS INDICATED) 40 1$ SINGLE RECEPTACLE, CEILING MOUNTED SINGLEMODE 0 DUPLEX RECEPTACLE, CEILING MOUNTED SPECS SPECIFICATIONS DOUBLE DUPLEX RECEPTACLE, CEILING MOUNTED DEVICE Qj CEILING CORD DROP, 120V, SINGLE PHASE N/A DOWN POWER POLE N/A DW MULTI -OUTLET ASSEMBLY (DEVICES AS INDICATED) o TELECOM MUNICA110NS EPO DUPLEX RECEPTACLE, SURGE PROTECTOR TYPE DOUBLE DUPLEX RECEPTACLE, SURGE PROTECTOR TYPE GENERAL NOTES 1. COMPLY WITH THE NATIONAL ELECTRICAL CODE AS ADOPTED AND AMENDED BY THE LOCAL AUTHORITY HAVING JURISDICTION. 2. THE LOCATIONS OF ELECTRICAL DEVICES OR LIGHTING FIXTURES INDICATED ON ARCHITECTURAL PLANS ELEVATIONS OR SECTIONS TAKE PRECEDENCE OVER LOCATIONS INDICATED ON THE ELECTRICAL DRAWINGS. ABBREVIATIONS ABV ABOVE MCC MOTOR CONTROL CENTER AC 3" ABOVE COUNTER BACKSPLASH MDF MAIN DISTRIBUTION FRAME/FACILITY ACH ABOVE COUNTER HEIGHT MH MANHOLE AFF ABOVE FINISHED FLOOR MM MULTIMODE AG ABOVE GRADE MTD MOUNTED A,AMP AMPERE MW MICROWAVE A/V AUDIO/VISUAL N NEUTRAL ATS AUTOMATIC TRANSFER SWITCH NIC NOT IN CONTRACT AWG AMERICAN WIRE GAUGE OPER OPERATER/OPERABLE CAN COMMUNITY ACCESS TELEVISION OP01 OWNER PROVIDED OWNER INSTALLED CB CIRCUIT BREAKER PB PULLBOX CCN CLOSED CIRCUIT TELEVISION PNL PANEL, PANELBOARD CKT CIRCUIT POS POSITION/POINT OF SALE CLG CEILING PR PAIR CM CEILING MOUNTED PTS PNEUMATIC TUBE STATION COMM COMMUNICATIONS R RACEWAY C CONDUIT RO RACEWAY ONLY CO CONDUIT ONLY RECEPT RECEPTACLE CTRL CONTROL REF REFRIGERATOR CU COPPER SLV SLEEVE D DATA SM SINGLEMODE DED DEDICATED SPECS SPECIFICATIONS DEV DEVICE SW SWITCH DN DOWN SWBD SWITCHBOARD DW DISHWASHER TELECOM TELECOM MUNICA110NS EPO EMERGENCY POWER OFF TGB TELECOMMUNICATIONS GROUNDING EWC ELECTRIC WATER COOLER BUSBAR FA FIRE ALARM TMGB TELECOMMUNICATIONS MAIN FB FLOOR BOX GROUNDING BUSBAR FBOIC FURNISHED BY OTHERS, INSTALLED TSER TELECOMMUNICATIONS SERVICE BY CONTRACTOR ENTRANCE ROOM FI FILM ILLUMINATOR TV TELEVISION FO FIBER OPTIC(AL) TYP TYPICAL FOC FACE OF COLUMN OF UNDER FLOOR G,GND GROUND UG UNDER GROUND GD GARBAGE DISPOSAL UON UNLESS OTHERWISE NOTED GFI,GFCI GROUND FAULT CIRCUIT UTP UNSHIELDED TWISTED PAIR INTERRUPTER V VOLT OR VOICE HH HAND HOLE VEL VERIFY EXACT LOCATION HP HORSEPOWER W WIRE, WATT, OR WALLPHONE IDF INTERMEDIATE DISTRIBUTION WAP WIRELESS ACCESS POINT FRAME/FACILITY WP WEATHERPROOF IH INSTA-HOT WATER DISPENSER XFMR TRANSFORMER J -BOX JUNCTION BOX 0 PHASE MAG MAGNETIC ELECTRICAL SHEET INDEX SHEET NO. SHEET TITLE E-001 SYMBOLS & ABBREVIATIONS E-101 ELECTRICAL POWER PLAN E-102 MAIN ELECTRICAL ROOM LAYOUT & MCC -1 ELEVATION E-601 PARTIAL ELECTRICAL POWER RISER E-602 LOAD CALCULATIONS, PANEL SCHEDULES E-701 SPECIFICATION Total Number of sheets: 6 no.I date I by I ckd I description 1 111/04/161 JJJ I KWL I ISSUED FOR PERMIT SEr-v,'nx1 E P!: � PIT E,,U�tEJ FOR: M Mechaniraj EI ctrical ,. Pt bIng ElKas pipl-no Citbr of Tukwila REVISIONS No changes shall be ma a to th scope of viork %mithout prior approv of Tulm-, la Building Division NOTE: F.�:'Isiom will require a ne,v pla submittal and may Include additional plan revi w fees. I= con Permit , �zl0 ~11 1 Plan review approval is subject to a Mrs and omiozsions. Approval of construction document does not aut'ro :We the violation of any adopted code oi ordinance. Reczlpt of approved Field Copy 7dditics isacknowiedr,3d: By: Date: --___1z / 2A h/ City 0f BUILDING REVIEWED _FOR COMPLIANCE WITH NFPA 70 - NEC DEC 10 2016 J W \z- City ZCity of -Tukwila BUILDING DIVISION RECEIVED CITY OF TUKWILA DEC 15 2016 PERMIT CENTER } W' ,� = Vii. ��� Y': ••.VrI. 3 ON L Name Discipline License No. date 11/04116 designed U.MAMADAMINOV W J. KIM checked T. JANOF - .a Zayo Group Company ZAYO GROUP, LLC zCOLO - TUKWILA FACILITY 3311 INTERNATIONAL BLVD TUKWILA, WA 98188 SYLBOLS & ABBREVIATIONS project contract I CONTRACT drawing rev. .A -001 sheet 1 of 5 sheets file E001.DWG 0 A C C 0 F G H J E 0 U_ O LL N 3 U) N O E NE En L U C Pt P-05 FUTURE P-04 FUTURE P-03 - NEW P-02 - NEW P -01 - NEW 1 2 3 4 5 6 7 8 1 9 10 11 12 13 14 )7i'"IMtvw� fl� "vSY � j"�Uv DEC 16 2016 City 0f -`iUkWR RECEIVED CITY OF TUKWILA KWILA DEC 15 2016 PERMIT CENTER Name Discipline License No. no.I date I by I ckd I 1 111/04/161 JJJ I KWL description ISSUED FOR PERMIT 4100 194th Street SW Suite 400 Lynnwood Washington 98036-4613 (206) 667-0555 date 11/04/16 designed U.MAMADAMINOV detailed J. KIM checked T. JANOF _ _ a ,:2yo Group Ccmpany - ZAYO GROUP, LLC zCOLO - TUKWILA FACILITY 3311 INTERNATIONAL BLVD TUKWILA, WA 98188 ELECTRICAL PLAN project I contract CONTRACT drawing rev. -101 1 sheet 2 of 5 sheets file E101.DWG U D C 9 J E F C J E 2 U_ O T U 0 z M 0 a M x m Q 0 N 0 0 Z 0 w M I D Q co 0 C) i 0 i 1 2 GENERAL NOTES: 1. SET BREAKERS PER COORDINATION STUDY. FLAG NOTES: PROVIDE NEW LSI 700A, 65kAIC CIRCUIT BRE DEMOLISH EXISTING FEEDER AND BREAKER Al 3 : DEMOLISH EXISTING FEEDERS TO PUMPS, P1 RE -LABEL THEM AS 'SPARE' ON MCC -1. PROVIDE NEW 100A, 65kAIC CIRCUIT BREAKEI PROVIDE 2OA-1P BREAKER FOR CHILLER YAF 3 4 5 a SCL TRANSFORMER 4160/2400V DELTA J I I 7 8 9 10 11 12 TO DP1 DIST. PANEL100C3 100C3 100C3 TIE BREAKER 100C3 100C3 10 0 MECH C� 60OC4 CRA -2-B O O / / „NO" o (Q (4 (4 (4 (Q (4 Cn o ,S�R6 ,s9s� ,s26� 's S3 9 CRA -4-A 0 ATS -IB -MCC -A 600A 480V, 3PH-4W, 4 -POLE 42k AIC MECH MECH MECH CRA -3-A 600C4 CODE SIZE SPLICE BOX CRA -5-A )0C3 100C3 100C3 ATS CRA -1 THRU 5 100A MANUAL TRANSFER SWITCH 65K AIC, TYP 60OC4 60ONG 100AS 90AF CRAC-8 TXG-1 75kVA TRANSFORMER 480V PRIMARY 208/120V SECONDARY �T� PANEL I I I PANEL NEW BREAKER LIST FOR PANEL'LA' CIRCUIT NUMBER BREAKERSIZE CD (b Q (�CD 22 20A -1P, 10kAIC CHILLER YARD RECEPTACLE (GF) CD q 20A -1P, 10kAIC o v' 34 J CHILLER (CH -01) CONTROL CIRCUIT 100AS 90AF CRAC-8 TXG-1 75kVA TRANSFORMER 480V PRIMARY 208/120V SECONDARY �T� PANEL I I I PANEL �o MCC 600A 480/277V s9� NEW BREAKER LIST FOR PANEL'LA' CIRCUIT NUMBER BREAKERSIZE BREAKER DESCRIPTION 22 20A -1P, 10kAIC CHILLER YARD RECEPTACLE (GF) 32 20A -1P, 10kAIC CHILLER (CH -01) CONTROL CIRCUIT 34 15A -1P, 10kAIC CHILLER (CH -01) CONTROL CIRCUIT 36 20A -1P, 10kAIC CHILLER (CH -02) CONTROL CIRCUIT 38 15A-iP, 10kAIC CHILLER (CH -02) CONTROL CIRCUIT �o MCC 600A 480/277V s9� by I ckd I CD C) (bo Jo� -1, 80OC3 Cn C:)azo a- Z O Co Al -BATT1 4 O 600A I Q( o f Q( o f Q\ Q( �- a � ��® O O �®aC` �- O O N cn cn O O O o 0 I 600A ZZ Q O r� Q D' (O J O Q N L0- CONVRTR 52L "NC" q Ln �o q r� 1 0 800A/3P �U) 1-1/4'C, 3#4, 1 #8G S S 480V, 3PH-3W, 65K AIC VFD VFD VFD PANEL z(A z< T TXG-2 75kVA TRANSFORMER :E m :2 m 1-1/4'C, 3#4, 1#8G HB 480V PRIMARY 208/120V SECONDARY P-03 P-01 P-02 50HP 50HP 50HP PANEL LB (2) 3-1/2'C, 3-50OKCMIL, 1#1/OG (2) 3-1/2'C, 3-500KCMIL, 1#1/OG PANEL HM1 531 M) CA ��� j 80OC3 13 14 ATS -MV -13 ATS -MV -A 600A 600A 4160, 3PH-3W, 4160, 3PH-3W, 40K AIC, 3 -POLE 40K AIC, 3 -POLE 4160V TXMV1A 4160V 480/277SEC T 480/277SEC 2500 kVA2500 kVA NEMA 3R = by I ckd I CD C) (bo Jo� Fn 80OC3 Cn C:)azo a- Z O Co 80OC3 13 14 ATS -MV -13 ATS -MV -A 600A 600A 4160, 3PH-3W, 4160, 3PH-3W, 40K AIC, 3 -POLE 40K AIC, 3 -POLE 4160V TXMV1A 4160V 480/277SEC T 480/277SEC 2500 kVA2500 kVA NEMA 3R = BATT by I ckd I CD C) ( Fn 80OC3 cn - o a- Z O C D BATT by I ckd I description "A1 -BATTY BATT JJJ 80OC3 A1-BATT2" BATT 80OC3 Al -BATT1 600A I NEW 500kW 0 600A UPS -A1 Cl.- J� o 0 I 600A ZZ Q O K r� Q D' (O J O Q N L0- CONVRTR 52L "NC" q Ln �o q r� 1 0 800A/3P �U) U,U" S S 480V, 3PH-3W, 65K AIC S NINVR. S z(A z< (� :E m :2 m 80OC3 NEW 500kW UPS -Bi CONVRTR J CONVRTR INVR. (o CO Q ` (nn �o J 00 GFI 3000A s, s BATT BATT "B1 -BATTY BATT "61-BATT2" "B1 -BATT1 " 600A �� 600A o �600A � o 0 a - O ( J Q (O J N O Q N 00p� Co� Cl -LO BP -B1 800A PANEL 1 48OV, 3PH-3W, 65K AIC RECEIVED CITY OF TUKWILA DEC 15 2016 PERMIT CENTER no.I date I by I ckd I description 1 111/04/161 JJJ 80OC3 I 80OC3 "NO„ Cl.- a - ZZ Q O K r� Q D' (O J O Q N r7 Q( J O N — cin o0o J 52L "NC" q Ln �o q r� 1 0 800A/3P BP -A1 800A PANEL LSI 480V, 3PH-3W, 65K AIC 800C3 TO PANEL U1DP2 80OC3 NEW 500kW UPS -Bi CONVRTR J CONVRTR INVR. (o CO Q ` (nn �o J 00 GFI 3000A s, s BATT BATT "B1 -BATTY BATT "61-BATT2" "B1 -BATT1 " 600A �� 600A o �600A � o 0 a - O ( J Q (O J N O Q N 00p� Co� Cl -LO BP -B1 800A PANEL 1 48OV, 3PH-3W, 65K AIC RECEIVED CITY OF TUKWILA DEC 15 2016 PERMIT CENTER no.I date I by I ckd I description 1 111/04/161 JJJ I KWL I ISSUED FOR PERMIT 80OC3 0� 4100 194th Street SW Suite 400 Lynnwood Washington 98036-4613 (206) 667-0555 "NO" ff-) date detailed K m a - 11/04/16 J. KIM ')NC" 52L V) 000 J designed checked 800A/3P LSI U.MAMADAMINOV T. JANOF 800C3 TO PANEL ':' U 1 DP 1 a Zayo Group Company ZAYO GROUP, LLC zCOLO - TUKWILA FACILITY 3311 INTERNATIONAL BLVD d W:A,�`TUKWILA, WA 98188 ONAL a e Disci line License No. PARTIAL ELECTRICAL POWER RISER project I contract CONTRACT drawing rev. ®601 1 sheet 4 of 5 sheets file E601.DWG D C V F G H 0 L E E LrU 2 0 U_ T co Cn 0 Z a d x M M v- 0 N 0 0 z 0 i m i Q i 00 0 i C.) Q co C=) i 1 2 3 4 5 6 7 8 1 9 10 11 12 13 14 SECTION 260100 - GENERAL PROVISIONS PROVIDE COMPLETE AND FULLY OPERATIONAL ALL ELECTRICAL SYSTEMS WITHIN THE PROJECT AREA, ALONG WITH POWER CONNECTIONS TO EQUIPMENT FURNISHED UNDER OTHER DIVISIONS OF THE SPECIFICATIONS. A. CODES: CONFORM TO THE NATIONAL ELECTRICAL CODE AND ALL OTHER CODES AND REGULATIONS AS ADOPTED AND AMENDED BY THE STATE OF WASHINGTON AND CITY OF SEATTLE INCLUDING THE AMERICANS WITH DISABILITIES ACT (ADA). B. PERMITS AND FEES: CONTRACTOR TO OBTAIN AND PAY FOR ALL REQUIRED LICENSES, PERMITS AND INSPECTIONS. C. COORDINATION: CONTRACTOR TO COORDINATE ELECTRICAL WORK WITH OTHER TRADES. D. WARRANTY: PROVIDE WARRANTY FOR ONE FULL YEAR AFTER COMPLETION. E. CONTRACT DRAWINGS: RACEWAYS AND OUTLET BOXES ARE SHOWN DIAGRAMMATICALLY ONLY AND THE LAYOUT DOES NOT NECESSARILY SHOW THE TOTAL NUMBER OF RACEWAYS NOR THEIR EXACT LOCATION. THE CONTRACTOR SHALL PROVIDE ALL RACEWAYS, BOXES, CABLES, AND OTHER MATERIALS REQUIRED FOR THE COMPLETE ELECTRICAL SYSTEMS SHOWN OR INDICATED ON THE CONTRACT DRAWINGS. F. RECORD DRAWINGS: AT THE CONCLUSION OF CONTACT WORK, PROVIDE THE OWNER WITH A COMPLETE SET OF REPRODUCIBLE DRAWINGS WITH ALL CHANGES CLEARLY AND LEGIBLY MARKED TO REFLECT THE AS -BUILT CONDITIONS. THESE DRAWINGS SHALL BE LABELED "AS -BUILT" AND CERTIFIED BY THE CONTRACTOR FOR ACCURACY. G. MAINTENANCE MANUALS: COMPLETE FOR EVERY SYSTEM. HARDBOARD COVERS WITH 3 RING BINDERS. H. QUALITY ASSURANCE: 1. MATERIALS AND SYSTEMS: PROVIDE UL LISTED AND LABELED MATERIALS WHERE LISTING SERVICE IS NORMALLY PROVIDED FOR A GIVEN PRODUCT. PROVIDE NEW AND SHIP TO JOBSITE IN ORIGINAL MANUFACTURER'S CONTAINERS OR BUNDLES. 2. WORKMANSHIP: ARRANGE WORK TO OBTAIN COORDINATED INSTALLATION. 3. DRAWINGS: FOR PURPOSE OF CLARITY AND LEGIBILITY, THE DRAWINGS ARE ESSENTIALLY DIAGRAMMATICAL ONLY. 4. ROUTING: EXACT ROUTING OF WIRING AND LOCATIONS OF OUTLETS, PANELS, ETC. SHALL BE GOVERNED BY STRUCTURAL CONDITIONS, OBSTRUCTIONS AND EXISTING CONDITIONS. ARCHITECT RESERVES THE RIGHT AT NO INCREASE IN PRICE, TO MAKE REASONABLE CHANGES IN LOCATIONS OF ELECTRICAL ITEMS EXPOSED AT CEILING AND/OR ON WALLS. COORDINATION: 1. WORK OUT ALL "TIGHT" CONDITIONS INVOLVING WORK UNDER THIS CONTRACT IN ADVANCE OF INSTALLATION. 2. COORDINATE ALL ELECTRICAL POWER AND CONTROL WIRING REQUIREMENTS OF MECHANICAL EQUIPMENT WITH MECHANICAL CONTRACTOR. 3. CONTRACTOR SHALL COORDINATE ALL TENANT -FURNISHED EQUIPMENT LOCATIONS AND CONNECTION REQUIREMENTS WITH TENANT'S VENDOR PRIOR TO ROUGH -IN. CONTRACTOR SHALL MAKE ALL FINAL UNE VOLTAGE CONNECTIONS TO EQUIPMENT AS REQUIRED. 4. CONFIRM ALL ELECTRICAL EQUIPMENT AND SYSTEM PROGRAMMING NOMENCLATURE REQUIREMENTS WITH -IN. CONFORM TO ALL NAMING CONVENTIONS DEFINED THE OWNER PRIOR TO SUBMITTALS AND ROUGH THROUGHOUT THE PROJECT. SECTION 260126 - TESTING A. FURNISH ALL LABOR AND TEST EQUIPMENT AS REQUIRED UNDER THIS SECTION. B. FACILITIES ENGINEERING REPRESENTATIVE NEEDS TO BE PRESENT FOR FINAL TESTING. C. TEST ALL PANELS AND/OR BRANCH CIRCUITS FOR GROUNDS OR SHORTS. REPAIR DEFECTIVE WIRING AS REQUIRED. TEST EACH INDIVIDUAL CIRCUIT AT PANEL FOR PROPER OPERATION. D. AT COMPLETION OF WORK, PROVIDE WRITTEN CERTIFICATION THAT ALL SYSTEMS ARE FUNCTIONING PROPERLY WITHOUT DEFECTS. SECTION 260500 - BASIC MATERIALS AND METHODS INCLUDES GENERAL REQUIREMENTS FOR MATERIALS AND INSTALLATION METHODS, CUTTING BUILDING CONSTRUCTION, PAINTING, CLEAN-UP, AND WORKMANSHIP. A. MATERIALS: ALL MATERIALS SHALL BE NEW FREE FROM DEFECTS, AND SHALL HAVE BEEN TESTED AND LISTED BY UNDERWRITERS LABORATORIES OR OTHER APPROVED TESTING ORGANIZATION AND SHALL BE SO LABELED. B. SUBSTITUTIONS: SHALL BE REVIEWED BY THE ENGINEER. C. WORKMANSHIP: SHALL BE OF THE BEST QUALITY AND PERFORMED BY EXPERIENCED ELECTRICIANS UNDER SUPERVISION OF AN EXPERIENCED FOREMAN. D. NOISE TRANSMISSION: TO PREVENT NOISE TRANSMISSION (IN NEW CONSTRUCTION) BETWEEN ADJOINING ROOMS, ALL DEVICES ON OPPOSITE SIDES OF WALL TO BE SPACE A MINIMUM OF 6" APART (HORIZONTALLY PREFERRED). E. BRANCH CIRCUITING: NO MORE THAN SIX CURRENT CARRYING CONDUCTORS IN ANY ONE (1) HOMERUN. F. GROUNDING: PROVIDE SEPARATE GREEN GROUNDING CONDUCTOR IN ALL EQUIPMENT AND RECEPTACLE BRANCH CIRCUITS. SIZE PER NEC. G. SUBMITTALS: AFTER AWARD OF CONTRACT, SUBMIT THREE COMMON BOUND BROCHURES TO ENGINEER (ONE COPY RETURNED TO CONTRACTOR) CONTAINING CATALOG CUTS AND/OR SHOP DRAWINGS FOR THE FOLLOWING ITEMS: H. CUTTING AND PATCHING: DO NOT CUT STRUCTURAL MEMBERS. ALL CONSTRUCTION MATERIALS DAMAGED OR CUT INTO DURING THE INSTALLATION OF THIS WORK MUST BE REPAIRED OR REPLACED WITH MATERIALS BY SKILLED LABOR EXPERIENCED IN THAT PARTICULAR BUILDING TRADE. 1. PAINTING: TOUCH-UP TO MATCH FACTORY PAINT ANY ELECTRICAL ITEMS SCRATCHED OR MARRED IN SHIPMENT OR INSTALLATION. J. CLEAN UP: CONTINUALLY REMOVE DEBRIS, CUTTINGS, CRATES, CARTONS, ETC. CAREFULLY CLEAN WIRING DEVICES, COVER PLATES, LIGHT FIXTURES, ETC., TO REMOVE PAINT AND PLASTER, ETC. SECTION 260510 - EXISTING SYSTEMS A. EXISTING SYSTEMS AND SYSTEMS ADJACENT TO THE WORK SHALL BE INVESTIGATED THOROUGHLY. ANY DAMAGE RESULTING FROM PERFORMANCE OF WORK UNDER THIS CONTRACT SHALL BE REPAIRED TO ASSURE CONTINUING OPERATION AND INTEGRITY DURING AND AT COMPLETION OF THE PROJECT AT NO INCREASE IN CONTRACT COST. ANY EXISTING WIRING SERVING DEVICES TO REMAIN IN SERVICE AND WHICH IS INTERRUPTED BY WORK PERFORMED UNDER THIS CONTRACT SHALL BE REROUTED TO MAINTAIN CIRCUIT CONTINUITY. CONTRACTOR SHALL ASSUME THE RISK OF MAINTAINING EXISTING SYSTEMS EXCEPT RELOCATION OF WIRING OF #2 AWG AND ABOVE SHALL BE CONSIDERED AN ADDITIONAL COST IF NOT SHOWN TO BE RELOCATED. IF SUCH WIRING IS FOUND THE CONTRACTOR SHALL NOTIFY ENGINEER OF WIRING LOCATION, REASON IT MUST BE REMOVED AND COST OF RELOCATION AND RECEIVE THE OWNER'S APPROVAL BEFORE PROCEEDING WITH THE WORK. THE BUILDING WILL CONTINUE OPERATION DURING THE WORK AND IT IS ESSENTIAL THAT NO SYSTEMS OPERATION BE INTERRUPTED UNLESS SCHEDULED WITH THE OWNER. CONTRACTOR SHALL ASSUME RESPONSIBILITY FOR UNSCHEDULED INTERRUPTIONS AND EXPEDIENT REPAIR. B. ALL CEILING AREAS IN PROJECT AREA. VERIFY THAT EXISTING RACEWAY SUPPORT SYSTEM FOR ALL EXISTING TO REMAIN RACEWAYS ABOVE EXISTING OR NEW ACCESSIBLE CEILINGS IS INSTALLED PER CODE. ADD NEW SUPPORTS AS NECESSARY. C. EXISTING SYSTEMS CONCEALED 1. THE ELECTRICAL DRAWINGS SHOW PORTIONS OF THE EXISTING ELECTRICAL SYSTEMS WHICH ARE TO REMAIN, BE REMOVED OR BE MODIFIED AS A PART OF THE CONTRACTOR'S WORK. CONCEALED FEATURES OF THE EXISTING SYSTEMS ARE DERIVED FROM RECORD DRAWINGS AND THE ENGINEER'S BEST JUDGMENT OF THE CONFIGURATION, BUT NO GUARANTEE IS MADE AS TO THEIR CORRECTNESS. 2. THE CONTRACTOR SHALL INSPECT THE EXISTING INSTALLATION PRIOR TO BIDDING AND SHALL MAKE HIS OWN JUDGMENT AS TO THE WORK REQUIRED TO PROVIDE A COMPLETE INSTALLATION AND DEMOU11ON WITHIN THE INTENT OF THE CONTRACT DOCUMENTS. D. EXISTING SYSTEM DRAWINGS THE DRAWINGS SHOW PORTIONS OF THE EXISTING SYSTEMS WHICH ARE DERIVED FROM RECORD DRAWINGS. THE DRAWINGS ARE INCOMPLETE AND NO GUARANTEE IS MADE TO THEIR CORRECTNESS. THE CONTRACTOR SHALL ASSUME THERE IS 20% MORE ELECTRICAL SYSTEMS THAN SHOWN ON THE DEMOLITION AND EXISTING SYSTEM DRAWINGS. E. DEMOLITION WORK ALL DEMOLITION WORK REQUIRED UNDER THIS CONTRACT IS NOT SHOWN ON THE DRAWINGS. THE CONTRACTOR SHALL REMOVE ALL ELECTRICAL EQUIPMENT IN THE AREA BEING REMODELED WHICH IS NO LONGER IN SERVICE PRESENTLY OR AS A RESULT OF THIS CONTRACT. THE DEFINITION OF ELECTRICAL EQUIPMENT IS ANY EQUIPMENT MENTIONED IN THE NATIONAL ELECTRICAL CODE. F. TEMPORARY ELECTRICAL EQUIPMENT REMOVING, TEMPORARY HANGING BY CHAINS AND REINSTALLING IN CEILINGS OF LIGHT FIXTURES, SPEAKERS, DETECTORS, EXIT SIGNS AND OTHER ELECTRICAL EQUIPMENT IS NOT SHOWN ON THE DRAWINGS. THE CONTRACTOR SHALL INVESTIGATE THE CEILING DEMOLITION WORK AND INCLUDE THIS WORK IN THE BID. THE SEQUENCE OF WORK SHALL BE (1) REMOVE AND STORE FIXTURES, DETECTORS AND SPEAKERS ALONG WITH REMOVAL OF CEILING, (2) PROVIDE TEMPORARY SUPPORT FOR WIRED FIXTURES AND DEVICES TO BE REINSTALLED IN NEW CEILING AT APPROXIMATELY THE SAME LOCATION. USE CHAINS FOR LIGHTING FIXTURE SUPPORT, (3) CLEAN AND REINSTALL 1N THE NEW OR REPLACED CEILINGS, PROVIDE NEW LAMPS WHEN SO NOTED. PROVIDE TEMPORARY RELOCATION OF EXIT SIGNS CONNECTED TO EXISTING EMERGENCY CIRCUITS AND REINSTALL IN THE ORIGINAL LOCATION WHEN EXIT IS REACTIVATED. G. PREMIUM TIME PREMIUM TIME SHALL BE INCLUDED IN THE BASE BID FOR ELECTRICAL SYSTEM(S) OUTAGES AND FOR OTHER WORK AS REQUIRED BY THE SCHEDULE, AS SHOWN ON THE DRAWINGS AND AS NOTED IN OTHER DIVISIONS OF THE SPECIFICATIONS. H. WORK OUTSIDE OF REMODEL AREAS CAUTION - THIS WORK IS NOT SHOWN ON THE CONTRACT DOCUMENTS. PROVIDE NEW WIRING SYSTEMS IN CONCEALED CEILING SPACES TO SWITCHBOARDS, PANELBOARDS, COMMUNICATION AND SIGNALING AND SYSTEM CONTROL PANELS. PROVIDE NEW CONDUIT SYSTEMS IN CEILING SPACES OF FLOOR BELOW REMODEL FLOORS. REMOVE AND RELOCATE ELECTRICAL EQUIPMENT IN THE WAY OF OTHER TRADES WORK INSTALLED UNDER THIS CONTRACT. SPACES ABOVE EXISTING CEILINGS ARE HIGHLY CONGESTED. ROUTE WIRING AROUND OBSTRUCTIONS AND PROVIDE PULL BOXES PER CODE. I. EXISTING MATERIALS ALL MATERIALS WHICH ARE A PART OF THE BUILDING SHALL REMAIN THE PROPERTY OF THE OWNER. J. EXISTING MATERIALS TO BE REINSTALLED EXISTING MATERIALS AND EQUIPMENT (EXCEPT INTERIOR, UNDAMAGED RACEWAYS) THAT ARE REMOVED AS A PART OF THE WORK OR STORED IN SURPLUS SHALL NOT BE REINSTALLED AS A PART OF THE NEW SYSTEMS UNLESS SPECIFICALLY NOTED OR AUTHORIZED IN WRITING BY THE OWNER. FORWARD A COPY OF THE AUTHORIZATION TO THE ENGINEER. THE REQUIREMENTS OF THE SPECIFICATIONS (I.E., CONDITION, INSTALLATION, TESTING, ETC.) SHALL APPLY AS IF THE MATERIALS WERE NEW, FURNISHED BY THE CONTRACTOR. K. EXISTING MATERIALS NOT TO BE REINSTALLED ALL MATERIAL TO BE DEMOLISHED AND DEBRIS SHALL BE LEGALLY DISPOSED OF BY THE CONTRACTOR. L EXISTING RACEWAYS THE CONTRACTOR MAY REUSE THE EXISTING RACEWAYS IF NO OTHER SYSTEMS OCCUPY THE RACEWAY, RACEWAYS AND ENCLOSURES ARE ELECTRICALLY AND MECHANICALLY CONTINUOUS AND NEW WIRING IS PROVIDED. NO WARRANTY IS MADE AND THE CONTRACTOR SHALL ASSUME THE RISK OF USING EXISTING OUTLET BOXES AND RACEWAY SYSTEMS. M. EXISTING CONDITIONS EXAMINE THE STRUCTURE, BUILDING, AND CONDITIONS UNDER WHICH ELECTRICAL WORK IS TO BE INSTALLED FOR CONDITIONS DETRIMENTAL TO PROPER AND TIMELY COMPLETION OF ELECTRICAL WORK. DO NOT PROCEED WITH WORK UNTIL DEFICIENCIES OR DETRIMENTAL CONDITIONS HAVE BEEN CORRECTED. REPORT DEFICIENCIES OR DETRIMENTAL CONDITIONS OF EXISTING ELECTRICAL WORK WHICH MIGHT BE UNSUITABLE TO CONNECT WITH OR RECEIVE OTHER WORK. FAILURE TO SO REPORT SHALL CONSTITUTE ACCEPTANCE OF OTHER WORK AS BEING FIT AND PROPER FOR THE RECEPTION OF ELECTRICAL WORK. N. EXISTING SYSTEMS MAINTAINED GENERAL REROUTE EXISTING CIRCUITS THAT ARE INTERRUPTED AS A RESULT OF THIS CONTRACT THAT SERVE DEVICES TO REMAIN IN SERVICE. 1. POWER CIRCUITS TRACE OUT AND IDENTIFY LOADS AND SYSTEMS BEING SERVED. PROVIDE TEMPORARY WIRING, SCHEDULE OUTAGE AND RECONNECT LOADS TO TEMPORARY WIRING. PROVIDE NEW WIRING IN NEW LOCATION. SCHEDULE OUTAGE, DISCONNECT TEMPORARY WIRING, AND CONNECT LOADS TO NEW WIRING. 2. SIGNAL AND COMMUNICATION SYSTEMS TRACE OUT AND IDENTIFY DEVICE AND SYSTEMS BEING SERVED. PROVIDE TEMPORARY WIRING TO MAINTAIN OPERATION OF SYSTEM THROUGHOUT FACILITY. SCHEDULE OUTAGE AND CONNECT TO TEMPORARY WIRING AND TEST SYSTEM. PROVIDE NEW WIRING AND NEW EQUIPMENT IN PROJECT AREA. SCHEDULE OUTAGE, DISCONNECT TEMPORARY WIRING AND CONNECT NEW WIRING AND NEW EQUIPMENT AND TEST SYSTEM. 0. DEMOLITION SIGNALING AND COMMUNICATION SYSTEMS, LIGHTING FIXTURES, OTHER ELECTRICAL EQUIPMENT FREE STANDING OR SURFACE MOUNTED, RACEWAY (EXPOSED) AND CONDUCTORS; WHICH ARE NO LONGER IN SERVICE PRESENTLY OR AS A RESULT OF THIS CONTRACT SHALL BE REMOVED. UNUSED FLUSH MOUNTED DEVICES, OUTLET AND OTHER BOXES IN FINISHED AREAS SHALL BE REMOVED FROM WALL AND THE REMAINING HOLE PATCHED TO MATCH ADJACENT WALL SURFACES. UNUSED RACEWAYS AND SLEEVES EMBEDDED IN CONCRETE SHALL BE CUT FLUSH AT CEILING, FLOOR OR WALL AND FILLED WITH GROUT. ALL UNUSED RACEWAYS ABOVE CEILINGS SHALL BE REMOVED. CONTRACTOR SHALL REMOVE ALL FLOOR, WALL OR CEILING MOUNTED ELECTRICAL EQUIPMENT IN THE "DEMOLITION AREA" INDICATED ON THE DRAWINGS EVEN IF THE EQUIPMENT/OR DEVICE IS NOT SHOWN ON THE PROJECT DRAWINGS. IF CONTRACTOR QUESTIONS WHETHER A PARTICULAR DEVICE IS TO BE REMOVED NOTIFY THE ENGINEER NOTING TYPE AND LOCATION OF DEVICE. IF SO DIRECTED THE CONTRACTOR SHALL MAINTAIN THE EXISTING DEVICE IN SERVICE WITHOUT ANY CHANGE IN CONTRACT PRICE. P. POWER OUTAGES 1. SCHEDULED OUTAGES. THE EXISTING FACILITY WILL CONTINUE ITS NORMAL OPERATION DURING THE CONSTRUCTION WORK; THEREFORE IT IS REQUIRED THAT THE CONTRACTOR SCHEDULE ELECTRICAL SYSTEM(S) OUTAGES WITH THE OWNER OR BUILDING MANAGEMENT. SUBMIT A WRITTEN REQUEST FOR A POWER OUTAGE AT LEAST ONE WEEK IN ADVANCE IDENTIFYING THE AREAS, AND SYSTEMS THAT WILL BE AFFECTED, TIME AND DURATION OF THE POWER OUTAGE. THE CONTRACTOR SHALL RECEIVE WRITTEN AUTHORIZATION TO PROCEED WITH THE OUTAGE AND SHALL RE -NOTIFY THE OWNER OR BUILDING MANAGEMENT VERBALLY AT LEAST ONE HOUR PRIOR TO THE OUTAGE AND ALSO N011FY THE OWNER WHEN THE OUTAGE IS COMPLETED. 2. UNSCHEDULED OUTAGES, IN THE EVENT THAT THE CONTRACTOR'S WORK CAUSES OR CONTRIBUTES TO AN UNSCHEDULED SYSTEM(S) OUTAGE (OR OTHER SYSTEM FAULT), THE CONTRACTOR IS RESPONSIBLE FOR IMMEDIATELY CORRECTING THE PROBLEM. INCLUDED (AS EXAMPLES) SHALL BE ANY PREMIUM TIME REQUIRED TO STAY ON TFE JOB SITE UNTIL PROBLEM IS CORRECTED AND AIR FREIGHT FOR PARTS NOT LOCALLY AVAILABLE. Q. ACCESS TO PERFORM WORK CAREFULLY REMOVE, STORE OR TEMPORARILY HANG AND RE -INSTALL IN UNDAMAGED CONDITION ALL ELECTRICAL EQUIPMENT, LGHTING FIXTURES AND CEILING 11LES WHERE ACCESS TO PERFORM WORK IS REQUIRED. CLEAN PRIOR 10 RE -INSTALLATION. R. NEW DEVICES IN REMODEL AREAS PROVIDE FLUSH MOUNTING FOR DEVICES IN EXISTING WALLS. FISH CONDUIT IN WALL WHERE EXISTING BOXES ARE INDICATED TO BE REUSED, EXTEND BOX AS NECESSARY AND PROVIDE NEW DEVICES AND PLATES. CONTRACTOR IS CAUTIONED THAT THE EXISTING BUILDING CONTAINS CLAY TILE AND CONCRETE WALLS. NEW DEVICES MAY REQU',RE CUTTING, PATCHING, AND PAINTING OF WALLS AND IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO PROVIDE ALL CUTTING, PATCHING AND PAINTING REQUIRED FOR THE INSTALLATION OF THE DIVISION 16 WORK. CONTRACTOR SHALL INVESTIGATE EXISTING AREAS PRIOR TO BID AND SHALL INCLUDE ALL COSTS OF SUCH WORK IN THE BID. THIS FACILITY HAS WIRING EMBEDDED IN RACEWAYS IN CONCRETE SLABS. PROVIDE NEW CONCEALED WIRING TO LAST OUTLET OR PULL BOX BEFORE HOMERUN TO PANEL. SECTION 260519 - LOW VOLTAGE ELECTRICAL POWER CONDUCTORS AND CABLES A. PROVIDE ALL WIRE AND CABLE COMPLETE. COPPER, INSULATED FOR 60OV. ALUMINUM OR COPPER CLAD ALUMINUM CONDUCTORS NOT PERMITTED. TYPE THW, THWN/THHN OR XHHW. NUMBER 12 AWG MINIMUM FOR POWER AND LIGHTING CIRCUITS. B. SPLICES: SOLDERLESS TYPE ONLY. PRE -INSULATED "TWIST -ON" TYPE (LIMITED TO SIZE #10 AND SMALLER). BOLT OR COMPRESSION .SET T)PE WITH APPLICATION OF PREFORMED INSULATED COVER, HEAT SHRINKABLE TUBING OR PLASTIC INSULATED TAPE ACCEPTABLE FOR ALL SIZES. C. TERMINATIONS: COMPRESSION SET, BOLTED OR SCREW TERMINAL CONDUCTORS #12 AND SMALLER SHALL UTILIZE EYE OR FORKED TONGUE TYPE COMPRESSION SET TERMINATOR WHEN TERMINATION IS TO A BOLTED SCREW SET TYPE TERMINAL BLOCK OR TERMINAL CABINET. D. COLOR CODE: 480 MARKING BRN, ORG, YELL, GRAY NEUTRAL 208 MARKING BLK, RED, BLU, WHITE NEUTRAL E. BRANCH CIRCUITS: COPPER. SOLID FOR NO.10 AWG AND SMALLER; STRANDED FOR NO.8 AWG AND LARGER. F. MULTICONDUCTOR CABLE IS PERMITTED ONLY AS DETAILED IN THE DRAWINGS. COMPLY WITH NEMA WC 70 FOR ARMORED CABLE, TYPE AC METAL -CLAD CABLE, TYPE MC AND TYPE SO WITH GROUND WIRE. G. ALL 480/277V WIRING WILL BE SEPARATED FROM THE 208/120V WIRING AT ALL TIMES. EXCEPTIONS: MOTOR CONTROLS. SECTION 260526 - GROUNDING PROVIDE A GROUNDING SYSTEM FOR EQUIPMENT AND DEVICE GROUND AS REQUIRED BY CODE. A. ALL NEW AND EXISTING RECEPTACLES TO HAVE GROUNDED POLES. SECTION 260533 - RACEWAYS AND BOXES A. PROVIDE RACEWAY SYSTEM COMPLETE AND IN CONFORMANCE WITH CODE. INSTALL RACEWAYS CONCEALED IN CONSTRUCTON FOR ALL AREAS UNLESS EXPOSED RACEWAYS ARE SPECIFICALLY SHOWN. B. PROVIDE 1" RACEWAY FOR HOMERUNS AND MAJOR CEILING CONDUIT RUNS. RACEWAY DROPS DOWN WALLS AND RACEWAY CARRYING 2 CURRENT CARRYING CONDUCTORS CAN BE 3/4". MINIMUM RACEWAY SIZE IS 3/4". C. PROVIDE PULLWMRE IN ALL EMPTY RACEWAYS. D. INTERIOR RACEWAYS: ELECTRICAL METALLIC TUBING (EMT) WITH STEEL COMPRESSION OR SET SCREW FITTINGS. INDENTOR, DRIVE -ON AND PRESSURE CAST ON DIE CAST TYPE SET SCREW FITTINGS ARE NOT ACCEPTABLE. E. RACEWAY PENETRATIONS: PENETRATIONS THROUGH FIRE RATED CONSTRUCTION SHALL BE SEALED USING 3M FIRE BARRIER CAULK, NELSON ELECTRIC FLAMESEAL OR T & B FLAMESAFE OR USE OTHER METHOD APPROVED BY THE ARCHITECT. F. PROVIDE AND SIZE OU -LET BOXES FOR DEVICES SUCH AS RECEPTACLES, SWITCHES AND LIGHT FIXTURES AND PULL BOXES AS REQUIRED IN THE CONDUIT SYSTEM PER THE NATIONAL ELECTRICAL CODE. CONTRACTOR SHALL COORDINATE WITH GENERAL CONTRACTOR TO DETERMINE ANY SPECIALTY INSTALLATION REQUIREMENTS DUE TO FIRE RATINGS, CORE WALLS, ETC. G. INTERIOR WIRING: PRESSED STEEL, ZINC COATED WITH PLASTER RING WHERE APPLICABLE. MOUNT OUTLET BOXES FOR RECEPtACLES AND OTHER DEVICES AT 18", UNLESS OTHERWISE NOTED. C. RECEPTACLES: 208V SINGLE PHASE RECEPTACLES: PROVIDE NEMA TYPE RECEPTACLES AS INDICATED ON DRAWINGS. DEVICES SHALL BE UL LISTED. PROVIDE DEVICES FROM ACCEPTABLE MANUFACTURERS; HUBBELL, LEVITON, PASS & SEYMOUR. GROUND FAULT CIRCUIT INTERRUPTER (GFCI) RECEPTACLE: SPECIFICATION GRADE, NEMA 5-15R CONFIGURATION, DUPLEX RECEPTACLE WITH 4-6 MILLIAMPS LEAKAGE CURRENT TRIP LEVEL FEED THROUGH TYPE TO PROTECT DOWNS -REAM RECEPTACLES ON THE SAME CIRCUIT. HUBBELL GFR5352L, LEVITON 7590 OR PASS & SEYMOUR 2095. COMBINATION GROUND FAULT CIRCUIT INTERRUPTER (GFCI) / SAFETY RECEPTACLE: COMBINATION U.L LISTED GFCI AND TAMPER RESISTANT RECEPTACLE, AUTOMATIC MECHANICAL SHUTTER TO PREVENT OBJECTS FROM BEING INSERTED INTO RECEPTACLES. PASS & SEYMOUR 2095TR, HUBBELL GFTR20. D. INTERIOR DEVICE PLATES: STAINLESS STEEL WITH 302 SATIN FINISH. E. IDENTIFICATION: EMERGENCY RECEPTACLES DEVICE PLATES SHALL BE LABELED WITH "EMERGENCY" ABOVE THE RECEPTACLE IN 3/16" HIGH RED FILLED LETTERS ALSO LABELED BELOW THE RECEPTACLE THE PANELBOARD AND CIRCUIT NUMBER SERVING THE RECEPTACLE. NORMAL RECEPTACLE DEVICE PLATES SHALL BE LABELED BELOW WITH PANELBOARDS AND CIRCUIT NUMBER (BLACK FILLED LETTERS). RECEPTACLE COVERPLATES FOR RECEPTACLES OTHER THAN 15 AND 20 AMP SHALL BE LABELED WITH AMPERE RATING, VOLTAGE AND PHASE. UTILIZE MACHINE PRINTED ADHESIVE FILM LABELS BY THERMAL TRANSFER OR EQUIVALENT PROCESS. F. PROVIDE A GFCI RECEPTACLE WITHIN 5'-0" OF ALL WATER SOURCES. ���II�P►i►�:��:3I��I1�d�1�1i+1��lI,YPI�l11�'ix�)�y;'J<t�1:1�� A. PROVIDE STANDARD DUTY TYPE DISCONNECT SWITCHES FOR EQUIPMENT, SIZED PER CODE. EQUIPMENT SIZING SHOWN ON DRAWINGS SHALL BE CONFIRMED AND REVISED AS REQUIRED TO MEET NEC. B. FUSES TO BE SIZED AS DIRECTED BY MECHANICAL EQUIPMENT MANUFACTURER. C. WEATHER PROOF SWITCHES NOTED "WP" TO BE NEMA 3R LISTED EQUIPMENT. D. IDENTIFICA11ON: PROVIDE ENGRAVED PHENOLIC NAMEPLATE FOR ALL DISCONNECTS. FOR EQUIPMENT CONNECTED TO EMERGENCY PROVIDE 3/16" HIGH WHITE FILLED LETTERS ON RED BACKGROUND IDENTIFYING EQUIPMENT SERVED AND THE PANELBOARD AND CIRCUIT NUMBER SERVING THE EQUIPMENT. FOR EQUIPMENT CONNECTED TO NORMAL PROVIDE 3/16" HIGH WHITE FILLED LETTERS ON BLACK BACKGROUND IDENTIFYING EQUIPMENT SERVED AND THE PANELBOARD AND CIRCUIT NUMBER SERVING THE EQUIPMENT SECTION 270533 - CONDUITS AND BACKBOXES FOR COMMUNICATIONS SYSTEMS PROVIDE OUTLET BOXES AND RACEWAYS READY FOR THE INSTALLATION OF COMMUNICATION CABLES BY OWNER. A. OUTLET BOXES: 4" SQUARE, 2" DEEP WITH SINGLE DEVICE PLASTER RING. B. COVERPLATES: BY OWNER. C. RACEWAYS: 3/4" FOR UP TO 4 CABLES, 1" FOR UP TO 6 CABLES WITH PLASTIC BUSHING ON ALL RACEWAY ENDS. ROUTE RACEWAY TO ABOVE ACCESSIBLE CEILING SPACE. CONFIRM AT BIDDING PERIOD ALL ROUTING REQUIREMENTS WITH OWNER FOR RACEWAY QUANTITIES AT BIDDING. PROVIDE PULL -STRING. E. IDENTIFICATION LABELS COMPLY WITH TTA/EIA-606-A AND APPLICABLE REQUIREMENTS IN THIS SECTION. MACHINE PRINTED SELF-ADHESIVE, SMUDGE RESISTANT LABELS FOR CABLES AND FACE -PLATES. LABELS SHALL BE APPROPRIATELY SIZED FOR CABLE DIAMETER. LABELS SHALL BE APPROPRIATELY COLORED FOR FACE -PLATE COLOR CONTRAST. SUBMIT SAMPLE LABELS FOR APPROVAL F. FOLLOW MANUFACTURERS' INSTRUCTIONS FOR INSTALLING COMPONENTS AND ADJUSTING ALL EQUIPMENT AND TELECOMMUNICATIONS CABLES. WHERE NO INSTRUCTIONS ARE INCLUDED WITH THE EQUIPMENT, FOLLOW ACCEPTED INDUSTRY PRACTICES AND WORKMANLIKE INSTALLATION STANDARDS. G. KEEP ALL ITEMS PROTECTED BEFORE AND AFTER INSTALLATION, WITH DUST AND WATER PROOF BARRIER MATERIALS AS NECESSARY. THE CONTRACTOR SHALL BE RESPONSIBLE TO ENSURE THE INTEGRITY OF THE PROTECTIVE MEASURES THROUGHOUT THE LIFE OF THE PROJECT. H. COMPLY WITH BICSI TCI, TIA/EIA-568-B.1, TIZ/EIA-568-B.2, TTA/EIA-568-8.3, AND TIA/EIA-569-A. I. 4 -PAIR UTP CABLE INSTALLATION PROVIDE 4 -PAIR UTP CABLES FROM THE IDF ROOMS TO THE COMMUNICATION OUTLETS AS SHOWN ON THE DRAWINGS. TERMINATE THE CABLES ONTO 8 -PIN MODULAR PANELS IN THE IDF AND ONTO 8 -PIN MODULAR CONNECTORS AT THE OUTLET LOCATION. ROUTE THE CABLES IN THE ACCESSIBLE CEILING AREA. SUPPORT THE CABLES WITH J -HOOKS INSTALLED AT A MAXIMUM SEPARATION OF 48 -INCHES IN ROUTE BACK TO THE CABLE TRAYS. DO NOT ALLOW UTP CABLES TO RUN PARALLEL WITH' ELECTRICAL CABLES/CONDUITS, UNLESS THEY ARE SEPARATED BY A MINIMUM OF 12 INCHES. ANY TELECOMMUNICATIONS CABLES THAT MUST CROSS OVER ELECTRICAL CABLES/CONDUITS SHALL DO SO ONLY AT 90 -DEGREE ANGLES. J. PROVIDE CATEGORY 6 8 -PIN MODULAR CONNECTORS FOR THE TERMINATION OF ALL 4 -PAIR CABLES. PROVIDE AN ACCOMPANYING FACEPLATE AND/OR MOUNTING PLATE AT THE APPROPRIATE OUTLET LOCATION. INSTALL FACEPLATES LEVEL AND ALIGN TO ADJACENT OUTLET FACEPLATES. K. IDENTIFICATION PROVIDE ON ALL OUTLET FACEPLATES INSTALLED UNDER THIS WORK, MACHINE -GENERATED LABELS WITH THE OUTLET ID, IN UPPERCASE LETTERING. LABEL SHALL BE OF A CONTRASTING COLOR TO THE FACEPLATE COLOR. PROVIDE ON ALL TERMINATION BLOCKS INSTALLED UNDER THIS WORK, MACHINE -GENERATED DESIGNATION STRIPS WITH THE CABLE ID AND PAIR NUMBER, IN UPPERCASE LETTERING. RECEIVED CITY OF Tt KWiLA DEC 15 2016 PERMIT CENTER Name Discipline License No. 4100 194th Street SW Suite 400 Lynnwood Washington 98036-4613 (206) 667-0555 11/04/16 designed U.MAMADAMINOV detailed J. KIM checked T. JANOF SYLBOLS & ABBREVIATIONS project contract I CONTRACT drawing rev. -701 1 sheet 1 of 5 sheets file E701.DWG D C FBI C IF J no.I date I by I ckd I description SPECIFICATIONS 1 111/04/161 JJJ I KWL I ISSUED FOR PERMIT SECTION 260100 - GENERAL PROVISIONS PROVIDE COMPLETE AND FULLY OPERATIONAL ALL ELECTRICAL SYSTEMS WITHIN THE PROJECT AREA, ALONG WITH POWER CONNECTIONS TO EQUIPMENT FURNISHED UNDER OTHER DIVISIONS OF THE SPECIFICATIONS. A. CODES: CONFORM TO THE NATIONAL ELECTRICAL CODE AND ALL OTHER CODES AND REGULATIONS AS ADOPTED AND AMENDED BY THE STATE OF WASHINGTON AND CITY OF SEATTLE INCLUDING THE AMERICANS WITH DISABILITIES ACT (ADA). B. PERMITS AND FEES: CONTRACTOR TO OBTAIN AND PAY FOR ALL REQUIRED LICENSES, PERMITS AND INSPECTIONS. C. COORDINATION: CONTRACTOR TO COORDINATE ELECTRICAL WORK WITH OTHER TRADES. D. WARRANTY: PROVIDE WARRANTY FOR ONE FULL YEAR AFTER COMPLETION. E. CONTRACT DRAWINGS: RACEWAYS AND OUTLET BOXES ARE SHOWN DIAGRAMMATICALLY ONLY AND THE LAYOUT DOES NOT NECESSARILY SHOW THE TOTAL NUMBER OF RACEWAYS NOR THEIR EXACT LOCATION. THE CONTRACTOR SHALL PROVIDE ALL RACEWAYS, BOXES, CABLES, AND OTHER MATERIALS REQUIRED FOR THE COMPLETE ELECTRICAL SYSTEMS SHOWN OR INDICATED ON THE CONTRACT DRAWINGS. F. RECORD DRAWINGS: AT THE CONCLUSION OF CONTACT WORK, PROVIDE THE OWNER WITH A COMPLETE SET OF REPRODUCIBLE DRAWINGS WITH ALL CHANGES CLEARLY AND LEGIBLY MARKED TO REFLECT THE AS -BUILT CONDITIONS. THESE DRAWINGS SHALL BE LABELED "AS -BUILT" AND CERTIFIED BY THE CONTRACTOR FOR ACCURACY. G. MAINTENANCE MANUALS: COMPLETE FOR EVERY SYSTEM. HARDBOARD COVERS WITH 3 RING BINDERS. H. QUALITY ASSURANCE: 1. MATERIALS AND SYSTEMS: PROVIDE UL LISTED AND LABELED MATERIALS WHERE LISTING SERVICE IS NORMALLY PROVIDED FOR A GIVEN PRODUCT. PROVIDE NEW AND SHIP TO JOBSITE IN ORIGINAL MANUFACTURER'S CONTAINERS OR BUNDLES. 2. WORKMANSHIP: ARRANGE WORK TO OBTAIN COORDINATED INSTALLATION. 3. DRAWINGS: FOR PURPOSE OF CLARITY AND LEGIBILITY, THE DRAWINGS ARE ESSENTIALLY DIAGRAMMATICAL ONLY. 4. ROUTING: EXACT ROUTING OF WIRING AND LOCATIONS OF OUTLETS, PANELS, ETC. SHALL BE GOVERNED BY STRUCTURAL CONDITIONS, OBSTRUCTIONS AND EXISTING CONDITIONS. ARCHITECT RESERVES THE RIGHT AT NO INCREASE IN PRICE, TO MAKE REASONABLE CHANGES IN LOCATIONS OF ELECTRICAL ITEMS EXPOSED AT CEILING AND/OR ON WALLS. COORDINATION: 1. WORK OUT ALL "TIGHT" CONDITIONS INVOLVING WORK UNDER THIS CONTRACT IN ADVANCE OF INSTALLATION. 2. COORDINATE ALL ELECTRICAL POWER AND CONTROL WIRING REQUIREMENTS OF MECHANICAL EQUIPMENT WITH MECHANICAL CONTRACTOR. 3. CONTRACTOR SHALL COORDINATE ALL TENANT -FURNISHED EQUIPMENT LOCATIONS AND CONNECTION REQUIREMENTS WITH TENANT'S VENDOR PRIOR TO ROUGH -IN. CONTRACTOR SHALL MAKE ALL FINAL UNE VOLTAGE CONNECTIONS TO EQUIPMENT AS REQUIRED. 4. CONFIRM ALL ELECTRICAL EQUIPMENT AND SYSTEM PROGRAMMING NOMENCLATURE REQUIREMENTS WITH -IN. CONFORM TO ALL NAMING CONVENTIONS DEFINED THE OWNER PRIOR TO SUBMITTALS AND ROUGH THROUGHOUT THE PROJECT. SECTION 260126 - TESTING A. FURNISH ALL LABOR AND TEST EQUIPMENT AS REQUIRED UNDER THIS SECTION. B. FACILITIES ENGINEERING REPRESENTATIVE NEEDS TO BE PRESENT FOR FINAL TESTING. C. TEST ALL PANELS AND/OR BRANCH CIRCUITS FOR GROUNDS OR SHORTS. REPAIR DEFECTIVE WIRING AS REQUIRED. TEST EACH INDIVIDUAL CIRCUIT AT PANEL FOR PROPER OPERATION. D. AT COMPLETION OF WORK, PROVIDE WRITTEN CERTIFICATION THAT ALL SYSTEMS ARE FUNCTIONING PROPERLY WITHOUT DEFECTS. SECTION 260500 - BASIC MATERIALS AND METHODS INCLUDES GENERAL REQUIREMENTS FOR MATERIALS AND INSTALLATION METHODS, CUTTING BUILDING CONSTRUCTION, PAINTING, CLEAN-UP, AND WORKMANSHIP. A. MATERIALS: ALL MATERIALS SHALL BE NEW FREE FROM DEFECTS, AND SHALL HAVE BEEN TESTED AND LISTED BY UNDERWRITERS LABORATORIES OR OTHER APPROVED TESTING ORGANIZATION AND SHALL BE SO LABELED. B. SUBSTITUTIONS: SHALL BE REVIEWED BY THE ENGINEER. C. WORKMANSHIP: SHALL BE OF THE BEST QUALITY AND PERFORMED BY EXPERIENCED ELECTRICIANS UNDER SUPERVISION OF AN EXPERIENCED FOREMAN. D. NOISE TRANSMISSION: TO PREVENT NOISE TRANSMISSION (IN NEW CONSTRUCTION) BETWEEN ADJOINING ROOMS, ALL DEVICES ON OPPOSITE SIDES OF WALL TO BE SPACE A MINIMUM OF 6" APART (HORIZONTALLY PREFERRED). E. BRANCH CIRCUITING: NO MORE THAN SIX CURRENT CARRYING CONDUCTORS IN ANY ONE (1) HOMERUN. F. GROUNDING: PROVIDE SEPARATE GREEN GROUNDING CONDUCTOR IN ALL EQUIPMENT AND RECEPTACLE BRANCH CIRCUITS. SIZE PER NEC. G. SUBMITTALS: AFTER AWARD OF CONTRACT, SUBMIT THREE COMMON BOUND BROCHURES TO ENGINEER (ONE COPY RETURNED TO CONTRACTOR) CONTAINING CATALOG CUTS AND/OR SHOP DRAWINGS FOR THE FOLLOWING ITEMS: H. CUTTING AND PATCHING: DO NOT CUT STRUCTURAL MEMBERS. ALL CONSTRUCTION MATERIALS DAMAGED OR CUT INTO DURING THE INSTALLATION OF THIS WORK MUST BE REPAIRED OR REPLACED WITH MATERIALS BY SKILLED LABOR EXPERIENCED IN THAT PARTICULAR BUILDING TRADE. 1. PAINTING: TOUCH-UP TO MATCH FACTORY PAINT ANY ELECTRICAL ITEMS SCRATCHED OR MARRED IN SHIPMENT OR INSTALLATION. J. CLEAN UP: CONTINUALLY REMOVE DEBRIS, CUTTINGS, CRATES, CARTONS, ETC. CAREFULLY CLEAN WIRING DEVICES, COVER PLATES, LIGHT FIXTURES, ETC., TO REMOVE PAINT AND PLASTER, ETC. SECTION 260510 - EXISTING SYSTEMS A. EXISTING SYSTEMS AND SYSTEMS ADJACENT TO THE WORK SHALL BE INVESTIGATED THOROUGHLY. ANY DAMAGE RESULTING FROM PERFORMANCE OF WORK UNDER THIS CONTRACT SHALL BE REPAIRED TO ASSURE CONTINUING OPERATION AND INTEGRITY DURING AND AT COMPLETION OF THE PROJECT AT NO INCREASE IN CONTRACT COST. ANY EXISTING WIRING SERVING DEVICES TO REMAIN IN SERVICE AND WHICH IS INTERRUPTED BY WORK PERFORMED UNDER THIS CONTRACT SHALL BE REROUTED TO MAINTAIN CIRCUIT CONTINUITY. CONTRACTOR SHALL ASSUME THE RISK OF MAINTAINING EXISTING SYSTEMS EXCEPT RELOCATION OF WIRING OF #2 AWG AND ABOVE SHALL BE CONSIDERED AN ADDITIONAL COST IF NOT SHOWN TO BE RELOCATED. IF SUCH WIRING IS FOUND THE CONTRACTOR SHALL NOTIFY ENGINEER OF WIRING LOCATION, REASON IT MUST BE REMOVED AND COST OF RELOCATION AND RECEIVE THE OWNER'S APPROVAL BEFORE PROCEEDING WITH THE WORK. THE BUILDING WILL CONTINUE OPERATION DURING THE WORK AND IT IS ESSENTIAL THAT NO SYSTEMS OPERATION BE INTERRUPTED UNLESS SCHEDULED WITH THE OWNER. CONTRACTOR SHALL ASSUME RESPONSIBILITY FOR UNSCHEDULED INTERRUPTIONS AND EXPEDIENT REPAIR. B. ALL CEILING AREAS IN PROJECT AREA. VERIFY THAT EXISTING RACEWAY SUPPORT SYSTEM FOR ALL EXISTING TO REMAIN RACEWAYS ABOVE EXISTING OR NEW ACCESSIBLE CEILINGS IS INSTALLED PER CODE. ADD NEW SUPPORTS AS NECESSARY. C. EXISTING SYSTEMS CONCEALED 1. THE ELECTRICAL DRAWINGS SHOW PORTIONS OF THE EXISTING ELECTRICAL SYSTEMS WHICH ARE TO REMAIN, BE REMOVED OR BE MODIFIED AS A PART OF THE CONTRACTOR'S WORK. CONCEALED FEATURES OF THE EXISTING SYSTEMS ARE DERIVED FROM RECORD DRAWINGS AND THE ENGINEER'S BEST JUDGMENT OF THE CONFIGURATION, BUT NO GUARANTEE IS MADE AS TO THEIR CORRECTNESS. 2. THE CONTRACTOR SHALL INSPECT THE EXISTING INSTALLATION PRIOR TO BIDDING AND SHALL MAKE HIS OWN JUDGMENT AS TO THE WORK REQUIRED TO PROVIDE A COMPLETE INSTALLATION AND DEMOU11ON WITHIN THE INTENT OF THE CONTRACT DOCUMENTS. D. EXISTING SYSTEM DRAWINGS THE DRAWINGS SHOW PORTIONS OF THE EXISTING SYSTEMS WHICH ARE DERIVED FROM RECORD DRAWINGS. THE DRAWINGS ARE INCOMPLETE AND NO GUARANTEE IS MADE TO THEIR CORRECTNESS. THE CONTRACTOR SHALL ASSUME THERE IS 20% MORE ELECTRICAL SYSTEMS THAN SHOWN ON THE DEMOLITION AND EXISTING SYSTEM DRAWINGS. E. DEMOLITION WORK ALL DEMOLITION WORK REQUIRED UNDER THIS CONTRACT IS NOT SHOWN ON THE DRAWINGS. THE CONTRACTOR SHALL REMOVE ALL ELECTRICAL EQUIPMENT IN THE AREA BEING REMODELED WHICH IS NO LONGER IN SERVICE PRESENTLY OR AS A RESULT OF THIS CONTRACT. THE DEFINITION OF ELECTRICAL EQUIPMENT IS ANY EQUIPMENT MENTIONED IN THE NATIONAL ELECTRICAL CODE. F. TEMPORARY ELECTRICAL EQUIPMENT REMOVING, TEMPORARY HANGING BY CHAINS AND REINSTALLING IN CEILINGS OF LIGHT FIXTURES, SPEAKERS, DETECTORS, EXIT SIGNS AND OTHER ELECTRICAL EQUIPMENT IS NOT SHOWN ON THE DRAWINGS. THE CONTRACTOR SHALL INVESTIGATE THE CEILING DEMOLITION WORK AND INCLUDE THIS WORK IN THE BID. THE SEQUENCE OF WORK SHALL BE (1) REMOVE AND STORE FIXTURES, DETECTORS AND SPEAKERS ALONG WITH REMOVAL OF CEILING, (2) PROVIDE TEMPORARY SUPPORT FOR WIRED FIXTURES AND DEVICES TO BE REINSTALLED IN NEW CEILING AT APPROXIMATELY THE SAME LOCATION. USE CHAINS FOR LIGHTING FIXTURE SUPPORT, (3) CLEAN AND REINSTALL 1N THE NEW OR REPLACED CEILINGS, PROVIDE NEW LAMPS WHEN SO NOTED. PROVIDE TEMPORARY RELOCATION OF EXIT SIGNS CONNECTED TO EXISTING EMERGENCY CIRCUITS AND REINSTALL IN THE ORIGINAL LOCATION WHEN EXIT IS REACTIVATED. G. PREMIUM TIME PREMIUM TIME SHALL BE INCLUDED IN THE BASE BID FOR ELECTRICAL SYSTEM(S) OUTAGES AND FOR OTHER WORK AS REQUIRED BY THE SCHEDULE, AS SHOWN ON THE DRAWINGS AND AS NOTED IN OTHER DIVISIONS OF THE SPECIFICATIONS. H. WORK OUTSIDE OF REMODEL AREAS CAUTION - THIS WORK IS NOT SHOWN ON THE CONTRACT DOCUMENTS. PROVIDE NEW WIRING SYSTEMS IN CONCEALED CEILING SPACES TO SWITCHBOARDS, PANELBOARDS, COMMUNICATION AND SIGNALING AND SYSTEM CONTROL PANELS. PROVIDE NEW CONDUIT SYSTEMS IN CEILING SPACES OF FLOOR BELOW REMODEL FLOORS. REMOVE AND RELOCATE ELECTRICAL EQUIPMENT IN THE WAY OF OTHER TRADES WORK INSTALLED UNDER THIS CONTRACT. SPACES ABOVE EXISTING CEILINGS ARE HIGHLY CONGESTED. ROUTE WIRING AROUND OBSTRUCTIONS AND PROVIDE PULL BOXES PER CODE. I. EXISTING MATERIALS ALL MATERIALS WHICH ARE A PART OF THE BUILDING SHALL REMAIN THE PROPERTY OF THE OWNER. J. EXISTING MATERIALS TO BE REINSTALLED EXISTING MATERIALS AND EQUIPMENT (EXCEPT INTERIOR, UNDAMAGED RACEWAYS) THAT ARE REMOVED AS A PART OF THE WORK OR STORED IN SURPLUS SHALL NOT BE REINSTALLED AS A PART OF THE NEW SYSTEMS UNLESS SPECIFICALLY NOTED OR AUTHORIZED IN WRITING BY THE OWNER. FORWARD A COPY OF THE AUTHORIZATION TO THE ENGINEER. THE REQUIREMENTS OF THE SPECIFICATIONS (I.E., CONDITION, INSTALLATION, TESTING, ETC.) SHALL APPLY AS IF THE MATERIALS WERE NEW, FURNISHED BY THE CONTRACTOR. K. EXISTING MATERIALS NOT TO BE REINSTALLED ALL MATERIAL TO BE DEMOLISHED AND DEBRIS SHALL BE LEGALLY DISPOSED OF BY THE CONTRACTOR. L EXISTING RACEWAYS THE CONTRACTOR MAY REUSE THE EXISTING RACEWAYS IF NO OTHER SYSTEMS OCCUPY THE RACEWAY, RACEWAYS AND ENCLOSURES ARE ELECTRICALLY AND MECHANICALLY CONTINUOUS AND NEW WIRING IS PROVIDED. NO WARRANTY IS MADE AND THE CONTRACTOR SHALL ASSUME THE RISK OF USING EXISTING OUTLET BOXES AND RACEWAY SYSTEMS. M. EXISTING CONDITIONS EXAMINE THE STRUCTURE, BUILDING, AND CONDITIONS UNDER WHICH ELECTRICAL WORK IS TO BE INSTALLED FOR CONDITIONS DETRIMENTAL TO PROPER AND TIMELY COMPLETION OF ELECTRICAL WORK. DO NOT PROCEED WITH WORK UNTIL DEFICIENCIES OR DETRIMENTAL CONDITIONS HAVE BEEN CORRECTED. REPORT DEFICIENCIES OR DETRIMENTAL CONDITIONS OF EXISTING ELECTRICAL WORK WHICH MIGHT BE UNSUITABLE TO CONNECT WITH OR RECEIVE OTHER WORK. FAILURE TO SO REPORT SHALL CONSTITUTE ACCEPTANCE OF OTHER WORK AS BEING FIT AND PROPER FOR THE RECEPTION OF ELECTRICAL WORK. N. EXISTING SYSTEMS MAINTAINED GENERAL REROUTE EXISTING CIRCUITS THAT ARE INTERRUPTED AS A RESULT OF THIS CONTRACT THAT SERVE DEVICES TO REMAIN IN SERVICE. 1. POWER CIRCUITS TRACE OUT AND IDENTIFY LOADS AND SYSTEMS BEING SERVED. PROVIDE TEMPORARY WIRING, SCHEDULE OUTAGE AND RECONNECT LOADS TO TEMPORARY WIRING. PROVIDE NEW WIRING IN NEW LOCATION. SCHEDULE OUTAGE, DISCONNECT TEMPORARY WIRING, AND CONNECT LOADS TO NEW WIRING. 2. SIGNAL AND COMMUNICATION SYSTEMS TRACE OUT AND IDENTIFY DEVICE AND SYSTEMS BEING SERVED. PROVIDE TEMPORARY WIRING TO MAINTAIN OPERATION OF SYSTEM THROUGHOUT FACILITY. SCHEDULE OUTAGE AND CONNECT TO TEMPORARY WIRING AND TEST SYSTEM. PROVIDE NEW WIRING AND NEW EQUIPMENT IN PROJECT AREA. SCHEDULE OUTAGE, DISCONNECT TEMPORARY WIRING AND CONNECT NEW WIRING AND NEW EQUIPMENT AND TEST SYSTEM. 0. DEMOLITION SIGNALING AND COMMUNICATION SYSTEMS, LIGHTING FIXTURES, OTHER ELECTRICAL EQUIPMENT FREE STANDING OR SURFACE MOUNTED, RACEWAY (EXPOSED) AND CONDUCTORS; WHICH ARE NO LONGER IN SERVICE PRESENTLY OR AS A RESULT OF THIS CONTRACT SHALL BE REMOVED. UNUSED FLUSH MOUNTED DEVICES, OUTLET AND OTHER BOXES IN FINISHED AREAS SHALL BE REMOVED FROM WALL AND THE REMAINING HOLE PATCHED TO MATCH ADJACENT WALL SURFACES. UNUSED RACEWAYS AND SLEEVES EMBEDDED IN CONCRETE SHALL BE CUT FLUSH AT CEILING, FLOOR OR WALL AND FILLED WITH GROUT. ALL UNUSED RACEWAYS ABOVE CEILINGS SHALL BE REMOVED. CONTRACTOR SHALL REMOVE ALL FLOOR, WALL OR CEILING MOUNTED ELECTRICAL EQUIPMENT IN THE "DEMOLITION AREA" INDICATED ON THE DRAWINGS EVEN IF THE EQUIPMENT/OR DEVICE IS NOT SHOWN ON THE PROJECT DRAWINGS. IF CONTRACTOR QUESTIONS WHETHER A PARTICULAR DEVICE IS TO BE REMOVED NOTIFY THE ENGINEER NOTING TYPE AND LOCATION OF DEVICE. IF SO DIRECTED THE CONTRACTOR SHALL MAINTAIN THE EXISTING DEVICE IN SERVICE WITHOUT ANY CHANGE IN CONTRACT PRICE. P. POWER OUTAGES 1. SCHEDULED OUTAGES. THE EXISTING FACILITY WILL CONTINUE ITS NORMAL OPERATION DURING THE CONSTRUCTION WORK; THEREFORE IT IS REQUIRED THAT THE CONTRACTOR SCHEDULE ELECTRICAL SYSTEM(S) OUTAGES WITH THE OWNER OR BUILDING MANAGEMENT. SUBMIT A WRITTEN REQUEST FOR A POWER OUTAGE AT LEAST ONE WEEK IN ADVANCE IDENTIFYING THE AREAS, AND SYSTEMS THAT WILL BE AFFECTED, TIME AND DURATION OF THE POWER OUTAGE. THE CONTRACTOR SHALL RECEIVE WRITTEN AUTHORIZATION TO PROCEED WITH THE OUTAGE AND SHALL RE -NOTIFY THE OWNER OR BUILDING MANAGEMENT VERBALLY AT LEAST ONE HOUR PRIOR TO THE OUTAGE AND ALSO N011FY THE OWNER WHEN THE OUTAGE IS COMPLETED. 2. UNSCHEDULED OUTAGES, IN THE EVENT THAT THE CONTRACTOR'S WORK CAUSES OR CONTRIBUTES TO AN UNSCHEDULED SYSTEM(S) OUTAGE (OR OTHER SYSTEM FAULT), THE CONTRACTOR IS RESPONSIBLE FOR IMMEDIATELY CORRECTING THE PROBLEM. INCLUDED (AS EXAMPLES) SHALL BE ANY PREMIUM TIME REQUIRED TO STAY ON TFE JOB SITE UNTIL PROBLEM IS CORRECTED AND AIR FREIGHT FOR PARTS NOT LOCALLY AVAILABLE. Q. ACCESS TO PERFORM WORK CAREFULLY REMOVE, STORE OR TEMPORARILY HANG AND RE -INSTALL IN UNDAMAGED CONDITION ALL ELECTRICAL EQUIPMENT, LGHTING FIXTURES AND CEILING 11LES WHERE ACCESS TO PERFORM WORK IS REQUIRED. CLEAN PRIOR 10 RE -INSTALLATION. R. NEW DEVICES IN REMODEL AREAS PROVIDE FLUSH MOUNTING FOR DEVICES IN EXISTING WALLS. FISH CONDUIT IN WALL WHERE EXISTING BOXES ARE INDICATED TO BE REUSED, EXTEND BOX AS NECESSARY AND PROVIDE NEW DEVICES AND PLATES. CONTRACTOR IS CAUTIONED THAT THE EXISTING BUILDING CONTAINS CLAY TILE AND CONCRETE WALLS. NEW DEVICES MAY REQU',RE CUTTING, PATCHING, AND PAINTING OF WALLS AND IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO PROVIDE ALL CUTTING, PATCHING AND PAINTING REQUIRED FOR THE INSTALLATION OF THE DIVISION 16 WORK. CONTRACTOR SHALL INVESTIGATE EXISTING AREAS PRIOR TO BID AND SHALL INCLUDE ALL COSTS OF SUCH WORK IN THE BID. THIS FACILITY HAS WIRING EMBEDDED IN RACEWAYS IN CONCRETE SLABS. PROVIDE NEW CONCEALED WIRING TO LAST OUTLET OR PULL BOX BEFORE HOMERUN TO PANEL. SECTION 260519 - LOW VOLTAGE ELECTRICAL POWER CONDUCTORS AND CABLES A. PROVIDE ALL WIRE AND CABLE COMPLETE. COPPER, INSULATED FOR 60OV. ALUMINUM OR COPPER CLAD ALUMINUM CONDUCTORS NOT PERMITTED. TYPE THW, THWN/THHN OR XHHW. NUMBER 12 AWG MINIMUM FOR POWER AND LIGHTING CIRCUITS. B. SPLICES: SOLDERLESS TYPE ONLY. PRE -INSULATED "TWIST -ON" TYPE (LIMITED TO SIZE #10 AND SMALLER). BOLT OR COMPRESSION .SET T)PE WITH APPLICATION OF PREFORMED INSULATED COVER, HEAT SHRINKABLE TUBING OR PLASTIC INSULATED TAPE ACCEPTABLE FOR ALL SIZES. C. TERMINATIONS: COMPRESSION SET, BOLTED OR SCREW TERMINAL CONDUCTORS #12 AND SMALLER SHALL UTILIZE EYE OR FORKED TONGUE TYPE COMPRESSION SET TERMINATOR WHEN TERMINATION IS TO A BOLTED SCREW SET TYPE TERMINAL BLOCK OR TERMINAL CABINET. D. COLOR CODE: 480 MARKING BRN, ORG, YELL, GRAY NEUTRAL 208 MARKING BLK, RED, BLU, WHITE NEUTRAL E. BRANCH CIRCUITS: COPPER. SOLID FOR NO.10 AWG AND SMALLER; STRANDED FOR NO.8 AWG AND LARGER. F. MULTICONDUCTOR CABLE IS PERMITTED ONLY AS DETAILED IN THE DRAWINGS. COMPLY WITH NEMA WC 70 FOR ARMORED CABLE, TYPE AC METAL -CLAD CABLE, TYPE MC AND TYPE SO WITH GROUND WIRE. G. ALL 480/277V WIRING WILL BE SEPARATED FROM THE 208/120V WIRING AT ALL TIMES. EXCEPTIONS: MOTOR CONTROLS. SECTION 260526 - GROUNDING PROVIDE A GROUNDING SYSTEM FOR EQUIPMENT AND DEVICE GROUND AS REQUIRED BY CODE. A. ALL NEW AND EXISTING RECEPTACLES TO HAVE GROUNDED POLES. SECTION 260533 - RACEWAYS AND BOXES A. PROVIDE RACEWAY SYSTEM COMPLETE AND IN CONFORMANCE WITH CODE. INSTALL RACEWAYS CONCEALED IN CONSTRUCTON FOR ALL AREAS UNLESS EXPOSED RACEWAYS ARE SPECIFICALLY SHOWN. B. PROVIDE 1" RACEWAY FOR HOMERUNS AND MAJOR CEILING CONDUIT RUNS. RACEWAY DROPS DOWN WALLS AND RACEWAY CARRYING 2 CURRENT CARRYING CONDUCTORS CAN BE 3/4". MINIMUM RACEWAY SIZE IS 3/4". C. PROVIDE PULLWMRE IN ALL EMPTY RACEWAYS. D. INTERIOR RACEWAYS: ELECTRICAL METALLIC TUBING (EMT) WITH STEEL COMPRESSION OR SET SCREW FITTINGS. INDENTOR, DRIVE -ON AND PRESSURE CAST ON DIE CAST TYPE SET SCREW FITTINGS ARE NOT ACCEPTABLE. E. RACEWAY PENETRATIONS: PENETRATIONS THROUGH FIRE RATED CONSTRUCTION SHALL BE SEALED USING 3M FIRE BARRIER CAULK, NELSON ELECTRIC FLAMESEAL OR T & B FLAMESAFE OR USE OTHER METHOD APPROVED BY THE ARCHITECT. F. PROVIDE AND SIZE OU -LET BOXES FOR DEVICES SUCH AS RECEPTACLES, SWITCHES AND LIGHT FIXTURES AND PULL BOXES AS REQUIRED IN THE CONDUIT SYSTEM PER THE NATIONAL ELECTRICAL CODE. CONTRACTOR SHALL COORDINATE WITH GENERAL CONTRACTOR TO DETERMINE ANY SPECIALTY INSTALLATION REQUIREMENTS DUE TO FIRE RATINGS, CORE WALLS, ETC. G. INTERIOR WIRING: PRESSED STEEL, ZINC COATED WITH PLASTER RING WHERE APPLICABLE. MOUNT OUTLET BOXES FOR RECEPtACLES AND OTHER DEVICES AT 18", UNLESS OTHERWISE NOTED. C. RECEPTACLES: 208V SINGLE PHASE RECEPTACLES: PROVIDE NEMA TYPE RECEPTACLES AS INDICATED ON DRAWINGS. DEVICES SHALL BE UL LISTED. PROVIDE DEVICES FROM ACCEPTABLE MANUFACTURERS; HUBBELL, LEVITON, PASS & SEYMOUR. GROUND FAULT CIRCUIT INTERRUPTER (GFCI) RECEPTACLE: SPECIFICATION GRADE, NEMA 5-15R CONFIGURATION, DUPLEX RECEPTACLE WITH 4-6 MILLIAMPS LEAKAGE CURRENT TRIP LEVEL FEED THROUGH TYPE TO PROTECT DOWNS -REAM RECEPTACLES ON THE SAME CIRCUIT. HUBBELL GFR5352L, LEVITON 7590 OR PASS & SEYMOUR 2095. COMBINATION GROUND FAULT CIRCUIT INTERRUPTER (GFCI) / SAFETY RECEPTACLE: COMBINATION U.L LISTED GFCI AND TAMPER RESISTANT RECEPTACLE, AUTOMATIC MECHANICAL SHUTTER TO PREVENT OBJECTS FROM BEING INSERTED INTO RECEPTACLES. PASS & SEYMOUR 2095TR, HUBBELL GFTR20. D. INTERIOR DEVICE PLATES: STAINLESS STEEL WITH 302 SATIN FINISH. E. IDENTIFICATION: EMERGENCY RECEPTACLES DEVICE PLATES SHALL BE LABELED WITH "EMERGENCY" ABOVE THE RECEPTACLE IN 3/16" HIGH RED FILLED LETTERS ALSO LABELED BELOW THE RECEPTACLE THE PANELBOARD AND CIRCUIT NUMBER SERVING THE RECEPTACLE. NORMAL RECEPTACLE DEVICE PLATES SHALL BE LABELED BELOW WITH PANELBOARDS AND CIRCUIT NUMBER (BLACK FILLED LETTERS). RECEPTACLE COVERPLATES FOR RECEPTACLES OTHER THAN 15 AND 20 AMP SHALL BE LABELED WITH AMPERE RATING, VOLTAGE AND PHASE. UTILIZE MACHINE PRINTED ADHESIVE FILM LABELS BY THERMAL TRANSFER OR EQUIVALENT PROCESS. F. PROVIDE A GFCI RECEPTACLE WITHIN 5'-0" OF ALL WATER SOURCES. ���II�P►i►�:��:3I��I1�d�1�1i+1��lI,YPI�l11�'ix�)�y;'J<t�1:1�� A. PROVIDE STANDARD DUTY TYPE DISCONNECT SWITCHES FOR EQUIPMENT, SIZED PER CODE. EQUIPMENT SIZING SHOWN ON DRAWINGS SHALL BE CONFIRMED AND REVISED AS REQUIRED TO MEET NEC. B. FUSES TO BE SIZED AS DIRECTED BY MECHANICAL EQUIPMENT MANUFACTURER. C. WEATHER PROOF SWITCHES NOTED "WP" TO BE NEMA 3R LISTED EQUIPMENT. D. IDENTIFICA11ON: PROVIDE ENGRAVED PHENOLIC NAMEPLATE FOR ALL DISCONNECTS. FOR EQUIPMENT CONNECTED TO EMERGENCY PROVIDE 3/16" HIGH WHITE FILLED LETTERS ON RED BACKGROUND IDENTIFYING EQUIPMENT SERVED AND THE PANELBOARD AND CIRCUIT NUMBER SERVING THE EQUIPMENT. FOR EQUIPMENT CONNECTED TO NORMAL PROVIDE 3/16" HIGH WHITE FILLED LETTERS ON BLACK BACKGROUND IDENTIFYING EQUIPMENT SERVED AND THE PANELBOARD AND CIRCUIT NUMBER SERVING THE EQUIPMENT SECTION 270533 - CONDUITS AND BACKBOXES FOR COMMUNICATIONS SYSTEMS PROVIDE OUTLET BOXES AND RACEWAYS READY FOR THE INSTALLATION OF COMMUNICATION CABLES BY OWNER. A. OUTLET BOXES: 4" SQUARE, 2" DEEP WITH SINGLE DEVICE PLASTER RING. B. COVERPLATES: BY OWNER. C. RACEWAYS: 3/4" FOR UP TO 4 CABLES, 1" FOR UP TO 6 CABLES WITH PLASTIC BUSHING ON ALL RACEWAY ENDS. ROUTE RACEWAY TO ABOVE ACCESSIBLE CEILING SPACE. CONFIRM AT BIDDING PERIOD ALL ROUTING REQUIREMENTS WITH OWNER FOR RACEWAY QUANTITIES AT BIDDING. PROVIDE PULL -STRING. E. IDENTIFICATION LABELS COMPLY WITH TTA/EIA-606-A AND APPLICABLE REQUIREMENTS IN THIS SECTION. MACHINE PRINTED SELF-ADHESIVE, SMUDGE RESISTANT LABELS FOR CABLES AND FACE -PLATES. LABELS SHALL BE APPROPRIATELY SIZED FOR CABLE DIAMETER. LABELS SHALL BE APPROPRIATELY COLORED FOR FACE -PLATE COLOR CONTRAST. SUBMIT SAMPLE LABELS FOR APPROVAL F. FOLLOW MANUFACTURERS' INSTRUCTIONS FOR INSTALLING COMPONENTS AND ADJUSTING ALL EQUIPMENT AND TELECOMMUNICATIONS CABLES. WHERE NO INSTRUCTIONS ARE INCLUDED WITH THE EQUIPMENT, FOLLOW ACCEPTED INDUSTRY PRACTICES AND WORKMANLIKE INSTALLATION STANDARDS. G. KEEP ALL ITEMS PROTECTED BEFORE AND AFTER INSTALLATION, WITH DUST AND WATER PROOF BARRIER MATERIALS AS NECESSARY. THE CONTRACTOR SHALL BE RESPONSIBLE TO ENSURE THE INTEGRITY OF THE PROTECTIVE MEASURES THROUGHOUT THE LIFE OF THE PROJECT. H. COMPLY WITH BICSI TCI, TIA/EIA-568-B.1, TIZ/EIA-568-B.2, TTA/EIA-568-8.3, AND TIA/EIA-569-A. I. 4 -PAIR UTP CABLE INSTALLATION PROVIDE 4 -PAIR UTP CABLES FROM THE IDF ROOMS TO THE COMMUNICATION OUTLETS AS SHOWN ON THE DRAWINGS. TERMINATE THE CABLES ONTO 8 -PIN MODULAR PANELS IN THE IDF AND ONTO 8 -PIN MODULAR CONNECTORS AT THE OUTLET LOCATION. ROUTE THE CABLES IN THE ACCESSIBLE CEILING AREA. SUPPORT THE CABLES WITH J -HOOKS INSTALLED AT A MAXIMUM SEPARATION OF 48 -INCHES IN ROUTE BACK TO THE CABLE TRAYS. DO NOT ALLOW UTP CABLES TO RUN PARALLEL WITH' ELECTRICAL CABLES/CONDUITS, UNLESS THEY ARE SEPARATED BY A MINIMUM OF 12 INCHES. ANY TELECOMMUNICATIONS CABLES THAT MUST CROSS OVER ELECTRICAL CABLES/CONDUITS SHALL DO SO ONLY AT 90 -DEGREE ANGLES. J. PROVIDE CATEGORY 6 8 -PIN MODULAR CONNECTORS FOR THE TERMINATION OF ALL 4 -PAIR CABLES. PROVIDE AN ACCOMPANYING FACEPLATE AND/OR MOUNTING PLATE AT THE APPROPRIATE OUTLET LOCATION. INSTALL FACEPLATES LEVEL AND ALIGN TO ADJACENT OUTLET FACEPLATES. K. IDENTIFICATION PROVIDE ON ALL OUTLET FACEPLATES INSTALLED UNDER THIS WORK, MACHINE -GENERATED LABELS WITH THE OUTLET ID, IN UPPERCASE LETTERING. LABEL SHALL BE OF A CONTRASTING COLOR TO THE FACEPLATE COLOR. PROVIDE ON ALL TERMINATION BLOCKS INSTALLED UNDER THIS WORK, MACHINE -GENERATED DESIGNATION STRIPS WITH THE CABLE ID AND PAIR NUMBER, IN UPPERCASE LETTERING. RECEIVED CITY OF Tt KWiLA DEC 15 2016 PERMIT CENTER Name Discipline License No. 4100 194th Street SW Suite 400 Lynnwood Washington 98036-4613 (206) 667-0555 11/04/16 designed U.MAMADAMINOV detailed J. KIM checked T. JANOF SYLBOLS & ABBREVIATIONS project contract I CONTRACT drawing rev. -701 1 sheet 1 of 5 sheets file E701.DWG D C FBI C IF J