Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Permit EL16-1164 - TUKWILA VILLAGE / BUILDING E - WIRING
TUKWILA VILLAGE BUILDING E 4450 S 144T" ST ELl 6=1 164 City of Tukwila • ``" Department of Community Development • 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Inspection Request Line: 206-438-9350 Web site: http://www.TukwilaWA.gov ELECTRICAL PERMIT Parcel No: 0040000180 Permit Number: EL16-1164 Address: 4450 S 144TH ST Issue Date: 1/20/2017 WA Cities Electrical Code: 2014 Permit Expires On: 7/19/2017 Project Name: TUKWILA VILLAGE BUILDING E 2014 Owner: 2015 WA State Energy Code: Name: TUKWILA CITY OF 2015 Address: 6200 SOUTHCENTER BLVD, TUKWILA, WA, 98188 Contact Person: Name: MITCH CHAMBERLIN Phone: (253) 770-0656 Address: PO BOX 849, SUMNER, WA, 98390 Contractor: Name: EVERGREEN STATE ELECTRIC INC Phone: (253) 770-0656 Address: PO BOX 849, SUMNER, WA, 98390 License No: EVERGSE066JA Expiration Date: 4/1/2018 Lender: Name: Address: DESCRIPTION OF WORK: WIRE ONE 125 UNIT APARTMENT BUILDING Valuation of single family: $0.00 Fees Collected: $10,584.86 Valuation of mf/comm: $750,000.00 Type of Work: NEW Electrical Service Provided by: SEATTLE CITY LIGHT Water District: 125 Sewer District: VALLEY VIEW Current Codes adopted by the City of Tukwila: International Building Code Edition: 2015 National Electrical Code: 2014 International Residential Code Edition: 2015 WA Cities Electrical Code: 2014 International Mechanical Code Edition: 2015 WAC 296-46B: 2014 Uniform Plumbing Code Edition: 2015 WA State Energy Code: 2015 International Fuel Gas Code: 2015 Permit Center Authorized Signature: ft Wk Date: lrv'o —1 I hearby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this development permit and agree to the conditions attached to this permit. Signature s=—G�/�i/2/ Date: Print Name: M7/ll-WP_'!.6 This permit shall become null and void if the work is not commenced within 180 days for the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. PERMIT CONDITIONS: 1: 'ELECTRICAL PERMIT CONDITIONS' 2: A copy of the electrical work permit shall be posted or otherwise made readily accessible to the Electrical Inspector at each work site. 3: Approved plans shall be maintained at the construction site and shall be readily available to the Electrical Inspector. 4: All electrical work shall be in accordance with NFPA 70 - NEC, and requirements for electrical installations, Chapter 296-46B WAC. S: When any portion of the electrical installation is to be hidden from view by permanent placement of parts of the building, such equipment shall not be concealed until it has been inspected and approved by the Electrical Inspector. 6: The issuance of an electrical work permit shall not be construed to be a permit for, or an approval of, any violation of the provisions of the electrical code or other ordinances of the jurisdiction. Permits or related documentation that presumes to grant this authority are therefore not valid. 7: Any change in the scope of work described by the electrical work permit shall require additional work permits. Where approved plans have been issued, revisions to the plans and additional review may be required. PERMIT INSPECTIONS REQUIRED Permit Inspection Line: (206) 438-9350 2100 ELECTRICAL FINAL 7003 ROUGH -IN ELECTRICAL 7002 SERVICE 7001 UNDERGROUND/SLAB CITY OF TUKW_ Community Development Department Permit Center • 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 htti)://www.TukwilaWA.gov SITE LOCATION Electrical Permit No.L-6��_ Project. No. Date Application Accepted: Date Application Expires: (For office use on10 ELECTRICAL PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. "Please Print" /� King Co Assessor's Tax No.: Site Address: �C"® �,��- I!// %I Suite Number: Floor: Tenant Name:RR&WILA V11-14-46 00 li%//J, , New Tenant: ❑..... Yes ❑..No CONTACT PERSON — person receiving all project communication Tivve of work: Address: k Name: City: Saw 0L State.4 zip, U�3-n Address: A4 T71 City: Weise Tukwila Business License No.: State:" Zip: . SG Phone: H:\Applications\Forms-Applications On Line\2014 Applications\Electrical Permit Application Revised 1-1.14.docx Fax: Email: `,�►W f Ga tl. ELECTRICAL CONTRACTOR INFOPJ%IATION Company Name: Tivve of work: Address: k Id New ❑ Addition City: Saw 0L State.4 zip, U�3-n Phone�� �� � Fax: 2__ Contr Reg �No.: � 333 Exp Date: Z.41/ 61- Tukwila Business License No.: ❑ Puget Sound Energy] Valuation of Project (contractor's bid price): $ ':Za/ —ox Scope of Work (please provide detailed information): WJ,,� /v)l�(h�7ij� l A)T,— Ji Will service be altered? ❑ Yes Type of Use: ❑ No Tivve of work: Id New ❑ Addition ❑ Service Change ❑ Low Voltage ❑ Generator ❑ Fire Alarm Property Served by: ❑ Puget Sound Energy] Seattle City Light H:\Applications\Forms-Applications On Line\2014 Applications\Electrical Permit Application Revised 1-1.14.docx Revised: July 2013 bh Adding more than 50 amps? ❑ Yes ❑ No ❑ Remodel ❑ Tenant Improvement ❑ Telecommunication ❑ Temporary Service Page I of 2 RESIDENTIAL NEW RESIDENTIAL SERVICE ❑ New single family dwellings ...................................$152.85 (including an attached garage) ❑ Garages, pools, spas and outbuildings ........................$81.90 ea ❑ Low voltage systems (alarm, furnace thermostat).................................$59.85 ea RESIDENTIAL REMODEL AND SERVICE CHANGES ❑ Service change or alteration .......................................$81.90 $65.00 ❑ (no added/altered circuits) $80.90 ❑ Service change with added/altered circuits.................$81.90 $86.25 number of added circuits .......................$11.55 ea ❑ Circuits added/altered without service change ............ $54.60 (up to 5 circuits) $10.80 ea ❑ Circuits added/altered without service change ............ $54.60 (6 or more circuits)...............................................$7.65 ea ❑ Meter/mast repair ........................................................$68.25 ❑ Low voltage systems .................................................$59.85 (alarm, furnace thermostat) PERMIT APPLICATION NOTES - MULTI -FAMILY AND COMMERCIAL Fees are based on the valuation of the electrical contract. MISCELLANEOUS FEES ❑ Temporary service (residential) .................................. $65.00 ❑ Temporary service (generator) ................................... $80.90 ❑ Manufactured/mobile home service ........................... $86.25 (excluding garage or outbuilding) ❑ Carnivals....................................................................$80.60 Number of concessions ......................... $10.80 ea Each ride and generator truck ................ $10.80 ea ***EFFECTIVE JANUARY 1, 2014 EACH PERMIT WILL BE ASSESSED A 5% TECHNOLOGY FEE*** Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The Building Official may grant one extension of time for an additional period not to exceed 90 days. The extension shall be requested in writing and justifiable cause demonstrated. I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER OR ELECTRICAL CONTRACTOR: Signature: Date: Z l✓ A� Print Name: ��/1/���1�/ir Day Telephone: ��' L/(✓' �6J`Z Mailing Address: City State Zip H:\Applications\Forms-Applications On Line\2014 ApplicationsTlectrical Permit Application Revised 1-1-14.docx Revised: July 2013 bh Page 2 of 2 DESCRIPTIONS • QUANTITY PAID PermitTRAK $8,549.31 EL16-1164 Address: 4450 S 144TH ST Apn: 0040000180 $8,549.31 ELECTRICAL $8,142.20 PERMIT FEE MULTI-FAM/COMM R000.322.101.00.00 0.00 $8,142.20 TECHNOLOGY FEE $407.11 TECHNOLOGY FEE TOTALPAID R000.322.900.04.00 0.00 $407.11 . .31 Date Paid: Friday, January 20, 2017 Paid By: EVERGREEN STATE ELECTRIC INC Pay Method: CHECK 1077 Printed: Friday, January 20, 2017 12:04 PM 1 of 1 SYSTEMS Date Paid: Monday, December 19, 2016 Paid By: EVERGREEN STATE ELECTRIC INC Pay Method: CHECK 1075 Printed: Monday, December 19, 2016 10:45 AM 1 of 1 SYSTEMS INSPECTION RE INSPECTION N0. Retain a copy with CITY OF TUKWILA BUIL 6300 Southcenter Blvd., #100, Tukwila. WA Permit Inspection Request Line (206) 438-93 CORD permit - t l PERMIT N0. DING DIVISION 98188 (206) 431-36 50 Project: Type of Inspection: _rA 4,6A Address: / Date Called: Special Instructions: Date Wanted: a I.M. Requester. Phone No: 10 Approved per applicable codes. LJ Corrections required prior to approval. s pectora REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call. to schedule reinspection. INSPECTION RECORD l INSPECTION N0. Retain a copy with permit CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431 - Permit Inspection Request Line (206) 438-9350 Project: / tJC a ' Type of Inspection: Address: ,�� �- C �! Date Called: Special Instructions: Date Wanted: -917 ( :m. Requester: Phone No:^� 3 EJApproved per applicable codes. LJ Corrections required prior to approval. F] REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. INSPECTION RECORD r Retain a copy with permit a INSPECTION NO. PERMIT N0. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-36. Permit Inspection Jequest Line (206) 438-9350 Project:✓K. w*G,c� Type of Inspection: Address: U /qq - R Date Called: Special Instructions: I Date Wanted: r1 M. p.m. Requester: Phone No: s DApproved per applicable codes. LJ Corrections required prior to approval. REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. INSPECTION RECORDP0 �l Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-36. Permit Inspection Request Line (206) 4350 n' Project:� / 6 Ty f I tion: X- � �� � Address:C t,/ J . / �� D e Cal ed: Special Instructions: Date Wanted: m. Q p.m. Requester: Phone No:� Approved per applicable codes. Corrections required prior to approval. 'i REINSPECTIONFFEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. INSPECTION RECORD 31 Retain a copy with permit INSPEC ION NO. PE MIT N0. CITY OF TUKWILA BUILDING 6300 Southcenter Blvd., #100, Tukwila. WA 98188 Permit Inspection R9quest Line (206) 438-9350 DIVISION (206) 431-3670 Project: � Type of Inspection: Address: t�qSF- Date Called: Special Instructions: I Date Wanted: a. p.m. Requester: Phone No: X5 1�� 3�V EJApproved per applicable codes. LJ Corrections required prior to approval. U paid at 6300 Southcenter Blvd., Suite 100. Gall to schedule reinspection. INSPECTION RECORD1 3) 7 Retain a copy with permit lip INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd- #100, Tukwila. WA 98188 (206) 431 - Permit Inspection pecluest Line (206) 438-9350 Project: Type of Inspection: Address: r 1go s . /�y 5r-. Date Called: Special Instructions: Date Wanted: �Q .m. Requester: Phone No: .0 4? J J 3 Approved per applicable codes.Corrections required prior to approval. COMMENTS: � Ob' T c +k0 REINSPECTION' FEE REQUIRED. Prior to next inspection, fee' must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. INSPECTION RECORD Retain a copy with permit hX7 INSPECTION NO. MIT N . CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-36 Permit Inspection, Request Line (206) 438-9350 Project: of Inspection: 1.Type Address:r Date Called: ql)ol' _ e Special Instructions: Date Wanted: I 3QP.M. Requester: Phone No: -r Z) 5 Approved per applicable codes. E Corrections required prior to approvAl. u paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. INSPECTION RECORD dd Retain a copy with permit ~ W INSPECTION N0, PERMIT N0. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-367 Permit Inspection Request Line (206) 438-9350 s' A Project: Type of Inspection: 6w-, Address: Date Called: Special Instructions: Date Wanted: �F p.m. .m. Requester: Phone No: 7 ` Approved per applicable codes. Corrections required prior to approval. U paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. INSPECTION RECORD V Regain a copy with permit INSPECTION NO. PERMIT 110. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-367 Permit Inspection�Request Line (206) 438-9350 Project:0 Type of Inspection: V1 1. Q Address: Date Called: Special Instructions: Date Wanted: m. Requester: Phone No: Z Approved per applicable codes. Corrections required prior to approval. L__I paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. INSPECTION RECORD Retain a copy with permit INSPECTION NO, PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3 Permit Inspection Request Line (206) 438-9350 Project: ' ` Type of Inspection: Address: ` Date Called: Special Ins ructions: Date Wanted: m. Requester: Phone No: :�5 SV - Approved per applicable codes. E Corrections required prior to ap roval. LJ paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. 32 ---INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT ZNO CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3 Permit Inspection Request Line (206) 438-9350 Project: %doh Iw, Type of Inspection: Address: ` Date Called: Special Instructions: Date Wanted: 7 Z3 fp-m. Requester: Phone No: 2—� 155 -JV ElApproved per applicable codes. E Corrections required prior to approval. LJ paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. INSPECTION RECORD Retain a copy with permitNI—lt& INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-367 U Approved per applicable codes. LJ Corrections required prior to approval. COMMENTS: FA n, aid fe-6 S G 14 tJ paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. INSPECTION RECORD 3� Retain a copy with permit INSPECTION NO. PERMIT N0. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-367 Permit Inspection Request Line (206) 438-9350 Project; e Type of Inspection: AlAddress: ! �,/ w�oSpecial Date Called: Instructions: Date Wanted: t P. Requester: Phone No: � 11 FlApproved per applicable codes. LJ Corrections required prior to approval. u paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. / I ('� C/ �q INSPECTION RECORD l Retain a copy with permit 64 INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-367 Permit Inspection Fecluest Line (206) 438-9350 cft,LA- ❑ Approved per applicable codes. Corrections required prior to approval. l __I paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. PA 2 INSPECTION RECORD Retain a copy with permit INSPEC N0. PERMIT N0. CITY OF TUKWILA BUILDING DIVISION i- 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Project: Type of 1 spection: fi' Lo V Address: Date Call Ll y 100 11-1114 t -k. Special Instructions: L2_iS- Date Wa t a.m. / p.m. Requester: Phone No: RApproved per applicable codes. E, I Corrections required prior to approval. COMMENTS: L MgALa 1211�ez tt 2) Efe-yo.--t-or L- �- w� 0 L. r -a w a i S+en i r- wE F1 RE10PECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. (etc INSPECTION RECORD (_ Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd.., #100, Tukwila: WA 98188 (206) 431-36 0 Permit Inspection Request Line (206) 438-9350 Project: Type of Inspection: Address. Date Called: Special Instructions: Date Wanted: A.rn, LP - Requester: Phone No: � � /-`� � •_ c Approved per applicable codes. LJ Corrections required prior to approval. '—' paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. INSPECTION RECORD Retain a copy with permit i d� l/ INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila: WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Project: � 1 Type of Inspection,��I Address: Date Called: Special Instructions: Date Wanted:7 a.m. .J Requester: Phone No: Approved per applicable codes. E Corrections required prior to approval. IInspector: `//!`%�PN�' IDate: C, I— /( I REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Catt to schedule reinspection. 7:7 1 INSPECTION RECORD INSPEC ION N0. Retain a copy with permit P MIT CITY OF TUKWILA BUILDING DIVISION & 6300 Southcenter Blvd- #100, Tukwila. WA 98188 (206) 431-367 Permit Inspection Request Line (206) 438-9350 1 Project: � , of inspection: Ty—pe�� &-/4� Address: .s- Date Called: Special Instructions: Date Wanted: 6 a.m. LZ'() p.m. Requester. 1 Phone No: / f Approved per applicable codes. E Corrections required prior to approval. COMMENTS: LAJ nNJ( Inspector: Date: J1 ei� I REINSPECTION FEE REQUIRED. Prior to next inspectioh. fee Must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. INSPECTION RECORD Retain a copy with permit INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 9 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-36 Permit Inspection/Request Line (206) 438-9350 Project:_ ^ Type of Inspection: �sV Address: c _ )v� Date Called: Special Instructions: Date Wanted: _p.m. Requester: Phone No: Approved per applicable codes. LJ Corrections required prior to approval. I___1 paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. INSPECTION RECORD Retain a copy with permitq INSPECTION NO. PERMIT N CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-367 Permit Inspecjon Rrquest Line (206) 438-9350 Project: �WLA-(,Xl Type of Inspection: chi Address -late �/ 1� /"[ SF' Called. Special Instructions: I Date Wanted: m. t� p• Requester: Phone No:� — t A-�7 Approved per applicable codes. Corrections required prior to approval. Iinspector: ' // {W /t5� Iuate: 1) ` /11 / I X REINSPECTIO-1FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. INSPECTION RECORD Z Retain a copy with permit -0 INSPEf ION NO. P RMIT N0. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection i equest Line (206) 438-9350 Project: �' (�1.� t Type of Inspection: Address: qq� Date Called: Special Instructions: I Date Wanted: .m. 42, p. Requester: Phone No: Approved per applicable codes. Corrections required prior to approval. I paid at 6300 Southcenter Blvd., Suite 100. Calf to schedule reinspection. INSPECTION RECORD 2-5 Retain a copy with permit '1 INSPECTION NO, P RMIT N0. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd_, #100, Tukwila. WA 98188 (206) 431-367 Permit Inspection Request Line (206) 438-9350 Project: Type of Inspection: Address: —_ L - S1 pate Called: -N Special Instructions: Date Wanted: .m. Requester: Phone No: •� �/ Approved per applicable codes. E Corrections required prior to approval. u paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. INSPECTION RECORD Retain a copy with permit ' INSPECTION N0, PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-36 00 Permit Inspection Request Line (206) 438-9350 w Project: t' Type of Inspection: ly (� pts . (� Address: a ��^IqV sr Date Called: Special Instr ctions: I Date Wanted: /a r p.m. ©(� L.4S \ Requester: Phone No: Approved per applicable codes. Q Corrections required prior to approval. COMMENTS: L11 rpector:Uf Dater (� REINS PECTI0N'FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. r INSPECTION RECORD l/I Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3 Permit Inspection Request Line (206) 438-9350 Project: (> J i L4, Type of Inspection: f Address:. / C_ Date Called: Special Instructions: S l op 1 Date Wanted: ( a. . 1 p.m Requester: Phone No:3 L��,,..�r' Approved per applicable codes. Corrections required prior to approval. COMMENTS: L r 5iLAJ , LAM 0J `�01-- i'DAJ I j ao nspector: ate: REINSPECTION FETE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. 2,o INSPECTION RECORD Retain a copy with permit f ` INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3 Permit Inspection Request Line (206) 438-9350 I n Project: / W' r✓ Type of Inspection: °4i Address:Date Y6-) .S. 1W S j Called: Special n tructions: I Date Wanted: a.m. p.m. Requester: Phone No: Approved per applicable codes. t__J Corrections required prior to approval. L_I paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. INSPECTION RECORD Retain a copy with permit INS PECTI ON N0. PERMIT N CITY OF TUKWILA BUILDING DIVISION t 6300 Southcenter Blvd.., #100, Tukwila. WA 98188 (206) 431-367 Permit Inspection Request Line (206) 438-9350 Project:__A r® i V LtiA'Jl Type of Inspection: �7g,]7,4 tV Address: ��y ler )<< • K 5,T-, Date Called: Special Instructions: 2 Date Wanted: 111Z- 7 a.m. Requester: Phone No: ��['� �� � ►, 3 ElApproved per applicable codes. LJ Corrections required prior to approval. COMMENTS: Ag ® N -OP L4 b 9 L-2 f- Iinspector: C hr7J leJ t—,( -k Iuate:Vq 141 W I REINSPECTION FEE REQUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. pPy INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd.., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Project: Vtllcse 131 Type of Inspection: TZ'P�5 I7 I Address: 9Date H H SO S I w tf r 1, Called: Special Instructions: IV.A Date Wanted: a.m. p.m. Requester: Phone No: Inspect r: S V." Date /2 /l REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. INSPECTION RECORD (7—Retain a copy with permit ��' INSPECTION N0. PERMIT N0. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd- #100, Tukwila. WA 98188 (206) 431-367 Permit Inspection Request Line (206) 438-9350 111 n: X54,4 Address: Date Called: Soecial Instructions: IDate Wanted: I� z'n. 1--;2 5 Requester: nApproved per applicable codes. t__J Corrections required prior to U paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. INSPECTION RECORD Retain a copy with permit .MMII �' INSP C ION N0. PERT N0. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-36 Permit Inspection Request Line (206) 438-9350 Project: f / iv' 6 Type of Inspection: td ' J Address: .,1 Date Called: Special Inst u ti ns: ac ��� Date Wanted: a.m. p.m Requester: Phone No: FlApproved per applicable codes. El Corrections required prior to approval. I paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. INSPECTION RECORD �rl' ��C� Retain a copy with permit V INSP CTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3 Permit Inspection Request Line (206) 438-9350 Project:��// / Type of Inspection:ga Address: c /q Date Called: r Special Instructions: Date Wanted: m. f it Requester: Phone No: mz Y'3 f nApproved per applicable codes. L1 Corrections required prior to approval. U paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. INSPECTION RECORD lRetain a copy with permit ' INSPE zTION NO. PERMIT No. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-36 Permit Inspection Request Line (206) 438-9350 Project:Type of Inspection: Address: .S - Date Called: Special Instructions: Date Wanted: �lo 7- p: Requester: �� 4 % Phone No: ` .,77 �o ElApproved per applicable codes. LJ Corrections required prior to approval. LJ paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. INSPECTION RECORD /6 Retain a copy with permit gNINS ECTION NO. PERMIT CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-36 Permit Inspection Request Line (206) 438-9350 ^ Project: �, / �� Type of Inspection: i Address: /� Date Called: Special Instr ctions: Date Wanted: a.m31),-7. p.m Requester: Phone No: FlApproved per applicable codes. LJ Corrections required prior to approval. U paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. INSPECTION RECORD Retain a copy with permit ' IN PECTION NO. PERMIT N0. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3 Permit lnsp�0on R (quest Line (206) 438-9350 Project:t l Type of Inspection;-4/Q� Address: (� �� t lqq r^ F Date Called: Special Instructions: Date Wanted: 'a:m. P• Requester: Phone No: Approved per applicable codes. Corrections required prior to approval. 01 u paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-36 Permit Inspection Request Line (206) 438-9350 Project: � Type of Inspection: /10 Address: Date Called: Special Instructions: Date Wanted: a.m. Requester: ' Phone No: 4K r i Approved per applicable codes. LJ Corrections required prior to approval. lJ paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. INSPECTION RECORD J t1W Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 63005o uthcenter Blvd., #100, Tukwila. WA 98188 (206) 431-36 Permit Inspection Request Line (206) 438-9350 4 U Approved per applicable codes. LJ Corrections required prior to approval. COMMENTS: Af 4L Kl�) i PJ J-� % ► zTA IInspector: -/F f4 jam/ /A/ (Date: 1),?,-/2-I'It? El REINSPECTION FtE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. INSPECTION RECORD Retain a copy with permit INSPECTION NO. P RMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-36 0 Permit Inspection Request Line (206) 438-9350 r Project: ,, 11 � Type of Inspection: Ko (J A i'r mi/ Address: // L Y ✓V 5 s V Y /_`/I]// q 5 _ f Date Called: Special Instructions: 6+WV5 Date Wanted: 7,, a.m.' ' � p.m. Requester: �— ` Phone No: ElApproved per applicable codes. LJ Corrections required prior to approval. COMMENTS: v 1 Ar --iDr OF U paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. t� INSPECTION RECORD I� Retain a copy with permit _4l INSPECTION NO. PERMIT N0. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-367 Permit Inspection Request Line (206) 438-9350 Project: IL ilk 61 Type of Inspection: Address: WDate UyS�/ �/• Called: Special Instructions: Date Wanted: a. m. Requester: Phone No: �/ ElApproved per applicable codes. E Corrections required prior to approvil. u paid at 6300 Southcenter Blvd., Suite 100. Catl to schedule reinspection. INSPECTION RECORD 7 Y/ Retain a copy with permit O. `(�! INSPECTION NPERMIT N0. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-367 Permit Inspection Request Line (206) 438-9350 Project: �� � Type of Inspect' n: I,1 Address: Date Called: Special Instructions: Pr7)Uc-� /u`' Date Wanted: a.m. 15. Requester: �✓J r7772-f' JV �" r EJApproved per applicable codes. LJ Corrections required prior to approval. COMMENTS: LOT A11+ C, C paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Project: Type of Insp io Address:K �� S- 5� Date Called: Special Instructions: Date Wanted: j m. p.m. Requester: Phone No: ❑ Approved per applicable codes. LJ Corrections required prior to approval. U paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. INSPECTION RECORD j� �qRetain a copy with permit ( '� l INSPECTION NO. P RMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 431-2451 Project: �ruL ,Lt e E' Type of Inspection: k Address: q) S, c �- Date Called: Special Instructions: Date Wanted:. a. p.m. Requester: Phone No: lei ZSJa DApproved per applicable codes. 11 Corrections required prior to approval. COMMENTS: f 1 s i LAA C -p D P f pector: El REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. INSPECTION RECORD I �j , b[V 1, E� Retain a copy with permit v `l INSPqCTION NO. PERMIT N0. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Project: rf, Type of Inspection: Address: LH 1� r - 5 i Date Called: Special Instructions: Date Wanted: p.m. Requester: Phone No: Approved per applicable codes. El Corrections required prior to approval. IInspector: C'/MY „ / L ,` IDate: 0712-1 11-7 I REINSPECTION FEE REQUIRED. Prior to next inspection, tee' must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. � INSPECTION RECORD �l Retain a copy with permi `t INSPECTION NO. PERMIT N0. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Project: Type of Inspection: Address: " C U Date Called: Special Instructions: Date Wanted: CP m.i m. Requester: Phone No: 25 3-3 F] Approved per applicable codes. Corrections required prior to approval. d nspector: Date: ❑ REINSPECTION FEE REQUIRED. Prior to next inspection, fere must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. INSPECTION RECORD �j Retain a copy with permit � 4 G-11 INSPECTION N0. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Project:i1r IV Type of Inspection: Address: t , Date Called: Special Instructions: Date Wanted: Lol p Requester: Phone No: Approved per applicable codes. Corrections required prior to approval. `—I paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. iCINSPECTION RECORD fi�6— Retain a copy with permit L INSPECTION N0. PERMIT N0. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-367 Permit Inspection Request Line (206) 438-9350 Project:, f � > L)/ . 1/�A C:1 Type o spection: ' Address: � Date Call d: Special Instructi ns Date Wanted: M. Lq p.m. Requester: fil-I Phone No: 2,.� r Approved per applicable codes. El Corrections required prior to approval. U paid at 6300 Southcenter Blvd., Suite 100. Calt to schedule reinspection. 6/5/2017 City of Tukwila Allan Ekberg, Mayor Department of Community Development Jack Pace, Director MITCH CHAMBERLIN PO BOX 849 SUMNER, WA 98390 RE: Permit No. ELI 6-1164 TUKWILA VILLAGE BUILDING E 4450 S 144 ST Dear Permit Holder: In reviewing our current records, the above noted permit has not received a final inspection by the City of Tukwila Building Division. Per the International Building Code, International Mechanical Code, Uniform Plumbing Code and/or the National Electric Code, every permit issued by the Building Division under the provisions of these codes shall expire by limitation and become null and void if the building or work authorized by such permit has not begun within 180 days from the issuance date of such permit, or if the building or work authorized by such permit is suspended or abandoned at any time after the work has begun for a period of 180 days. Your permit will expire on 7/19/2017. Based on the above, you are hereby advised to: 1) Call the City of Tukwila Inspection Request Line at 206-438-9350 to schedule for the next or final inspection. Each inspection creates a new 180 day period, provided the inspection shows progress. -or- 2) Submit a written request for permit extension to the Permit Center at least seven(7) days before it is due to expire. Address your extension request to the Building Official and state your reason(s) for the need to extend your permit. The Building Code does allow the Building Official to approve one extension of up to 180 days. If it is determined that your extension request is granted, you will be notified by mail. In the event you do not call for an inspection and/or receive an extension prior to 7/19/2017, your permit will become null and void and any further work on the project will require a new permit and associated fees. Thank you for your cooperation in this matter. Sincerely, 1 uuII �k Rachelle Ripley Permit Technician File No: ELI 6-1164 6300 Southcenter Boulevard Suite #100 • Tukwila, Washington 98188 • Phone 206-431-3670 • Fax 206-431-3665 City of Tukwila Allan Ekberg, Mayor Department of Community Development Jack Pace, Director December 22, 2016 MITCH CHAMBERLIN PO BOX 849 SUMNER, WA 98390 RE: Correction Letter # 1 ELECTRICAL Permit Application Number ELI 6-1164 TUKWILA VILLAGE BUILDING E - 4450 S 144 ST Dear MITCH CHAMBERLIN, This letter is to inform you of corrections that must be addressed before your development permit can be approved. All correction requests from each department must be addressed at the same time and reflected on your drawings. I have enclosed comments from the following departments: BUILDING - E DEPARTMENT: Jim Benner at 206-431-3679 if you have questions regarding these comments. • CORRECTIONS/ #1 1.) SHEET E500 TRIANGLE NOTE 3 REQUIRES 2/0 AL EGC FOR EACH CONDUIT PER 250.122 (F). 2.) SHEET E500 TRIANGLE NOTE 5 REQUIRES #1 AL EGC FOR EACH CONDUIT PER 250.122 (F). Please address the comments above in an itemized format with applicable revised plans, specifications, and/or other documentation. The City requires that two 2 sets of revised plan pages, specifications and/or other documentation be resubmitted with the appropriate revision block. In order to better expedite your resubmittal, a'Revision Submittal Sheet' must accompany every resubmittal. I have enclosed one for your convenience. Corrections/revisions must be made in person and will not be accepted through the mail or by a messenger service. If you have any questions, I can be reached at 206-431-3655. Sincerely, i C Bill Rambo Permit Technician File No. ELI 6-I 164 6300 Southcenter Boulevard Suite #100 • Tukwila Washington 98188 9 Phone 206-431-3670 • Fax 206-431-3665 PERMIT C";00111) COPY PLAN REVIEW/ROUTING SLIP PERMIT NUMBER: EL16-1164 DATE: 01/11/17 PROJECT NAME: TUKWILA VILLAGE BLDG E SITE ADDRESS: 4450 S 144TH ST Original Plan Submittal Revision # before Permit Issued X Response to Correction Letter # 1 Revision # after Permit Issued DEPARTMENTS: Building Division Is Fire Prevention Public Works ❑ Structural PRELIMINARY REVIEW: Not Applicable ❑ (no approval/review required) REVIEWER'S INITIALS: APPROVALS OR CORRECTIONS: Approved ❑ Corrections Required ❑ (corrections entered in Reviews) Notation: REVIEWER'S INITIALS: ❑ Planning Division ❑ ❑ Permit Coordinator ❑ DATE: 01/12/17 Structural Review Required ❑ DATE: DUE DATE: Approved with Conditions Denied ❑ (ie: Zoning Issues) DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Plug ❑ PW ❑ Staff Initials: 02/09/17 12/18/2013 PERMIT OOORD COPE PLAN REVIEW/ROUTING SLIP PERMIT NUMBER: EL16-1164 DATE: 12/19/16 PROJECT NAME: TUKWILA VILLAGE BUILDING E SITE ADDRESS: 4450 S 144 ST X Original Plan Submittal Revision # before Permit Issued Response to Correction Letter # Revision # after Permit Issued DEPARTMENTS: ,� Coyf 7- 0- 40 -Building Division 0 Fire Prevention ❑ Planning Division ❑ Public Works ❑ Structural ❑ Permit Coordinator PRELIMINARY REVIEW: DATE: 12/20/16 Not Applicable ❑ Structural Review Required ❑ (no approval/review required) REVIEWER'S INITIALS: APPROVALS OR CORRECTIONS: DATE: DUE DATE: 01/17/17 Approved ❑ Approved with Conditions ❑ Corrections Required (corrections entered in Reviews) Notation: Denied ❑ (ie: Zoning Issues) REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg' Fire ❑ Ping ❑ PW ❑ Staff Initials: — 12J18/2013 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Fax: 206-431-3665 Web site: http://www.ci.tukwila.wa.us ItEVISIQN. SUBMITTAL Revision submittals must be submitted in person at the Permit Center. Revisions will not be accepted through the mail, fax, etc. Date: 1-11-1-7 Plan ChecWPermit Number: EL 16-1164 ❑ Response to Incomplete Letter # RECEIVED ® Response to Correction Letter # 1 CCTV pF TUKWILA ❑ Revision # after Permit is Issued JAN i 1'20V ❑ Revision requested by a City Building Inspector or Plans Examiner PERMIT CENTER Project Name: Tukwila Village Building E Project Address: 4450 S 144 St Contact Person:_ (AMMIAI Phone Number: -Of -3— 6 Summary of Revision: Sheet Number(s): F-5Dy "Cloud" or highlight all areas of revision Received at the City of Tukwila Permit Cel ❑ Entered in TRAKiT on \applications\forms-applications on lme\revision submittal Created: 8-13-2004 Revised: EVERGREEN STATE ELECTRIC Tr Tr• Hcnne Espahol Contact Safety & Health Claims & Insurance Washington State Department of Labor & Industries EVERGREEN STATE ELECTRIC INC Owner or tradesperson PO BOX 849 SUMNER, WA 98390 Principals 253-770-0656 CHAMBERLIN, MITCHELL, PRESIDENT PIERCE County CHAMBERLIN, LYNDA K, VICE PRESIDENT CHAMBERLIN, LYNDA, AGENT WILKINSON, JESSICA, SECRETARY (End: 12/26/2012) Doing business as EVERGREEN STATE ELECTRIC INC WA UBI No. Business type 601 521 666 Corporation Governing persons LYNDA K CHAMBERLIN MITCHELL D CHAMBERLIN; License Page 1 of 3 Search L&ISvr:.' A -'L Index Help TV] y LCI Workplace Rights Trades & Licensing Verify the contractor's active registration / license / certification (depending on trade) and any past violations. Electrical Contractor Active. ................................................. Meets current requirements. License specialties GENERAL License no. EVERGSE066JA Effective — expiration 04/0111994— 04/0112018 Designated administrator CHAMBERLIN, MITCHELL License type Master Electrician Bond Contractors Bonding & Insurance Co Bond account no. SJ5622 Received by L&I 04/2412012 Bond history Savings No savings accounts during the previous 6 year period. License Violations ...............1..1...11................... Active. Meets current requirements. License no. CHAMBM'977KG $4,000.00 Effective date 04/01/2012 Expiration date Until Canceled Help us improve https:Hsecure.lni.wa.gov/verify/Detail.aspx?UBI=601521666&LIC=EVERGSE066JA&SAW= 1/20/2017 EVERGREEN STATE ELECTRIC NC Infraction no. EJORP05671 Issue date 08/15/2013 Violation city SUMNER Type of violation ELECTRICAL CITATION Description Failing to get an inspection or obtain an electrical/telecommunications work permit or post a provisional electrical work permit prior to beginning the electrical/telecommunication installation or alteration as referenced in WAC 296-466-901. (THIS CITATION WAS ISSUED IN MATRIX FORMAT. THIS CITATION IS INTENDED TO COVER SEVERAL PROJECTS) Satisfied ................... RCW/WAC 19.28.101 RCW Violation amount $4,000.00 Infraction no. EJORP05672Satisfied .................... Issue date RCW/WAC 08115/2013 19.28.101 RCW Violation city Violation amount SUMNER $250.00 Type of violation ELECTRICAL CITATION Description Energizing electrical equipment without an electrical inspection as referenced in WAC 296-466-901. Infraction no. ECAM000324 Issue date 01/2512012 Violation city SUMMNER Type of violation ELECTRICAL CITATION Description Failing to obtain or post an electrical/telecommunications work permit prior to beginning the electrical/telecommunication installation or alteration as referenced in WAC 296-46B-900 (3)(6), effective after 12/30/2008 see WAC 296- 466-901. Infraction no. ECAM000326 Issue date 0112512012 Violation city SUMMNER Type of violation ELECTRICAL CITATION Description Failing to request an inspection within 3 business days after completion of the installation or 1 business day after energizing, whichever occurs first as referenced in WAC 296 -46B -900(10)(a), effective after 12/30/2008 see WAC 296 -46B -901(10)(a). Infraction no. Satisfied ..................... RCW&'VAC 19.28.101 RCW Violation amount $1,000.00 Satisfied ..................... RCWIWAC 19.28.101 RCW Violation amount $250.00 Page 2 of 3 Help us improve https:Hsecure.Ini.wa.gov/verify/Detail.aspx?UBI=601521666&LIC=EVERGSE066JA&SAW= 1/20/2017 w D V / O D m 7) 6 O w N r` O Q0 w / V) 0 N 0 z� Q0 I Q 0) I O d - U Q) 0 O 4_J O n Ma'ww1 MN2• { _1VfWENIWlwT- .!� ,xar�wrwiwx'a ri_-, , ops wucr. a ... 2501/177 FiFVAm <.� U 1W u,o 1 A ELECTRICAL SYMBOLS LEGEND A DETAIL/SECTION IDENTIFICATION: A = DETAIL/SECTION LETTER, B = SHEET NUMBER B WHERE DETAIL/SECTION IS DRAWN. A EQUIPMENT CONNECTION CALLOUT. A,B EQUAL EQUIPMENT IDENTIFICATION ON B MECHANICAL EQUIPMENT CONNECTION SCHEDULES. VERIFY EXACT EQUIPMENT REQUIREMENTS ON SHOP DRAWING EQUIPMENT SUBMITTALS PRIOR TO ROUGH -IN. DO NO ROUGH -IN FOR EQUIPMENT PRIOR TO REVIEW OF SUBMITTALS. REPORT ANY DIFFERENCES IN REQUIREMENTS TO ENGINEER IN WRITING. CONDUIT CONCEALED. HASH MARKS INDICATE NUMBER OF #12 CONDUCTORS IN CODE SIZE CONDUIT. NO HASH MARKS INDICATES 2412 CONDUCTORS PLUS GROUND IN 314" CONDUIT, LONG HASH MARKS INDICATES NEUTRAL CONDUCTOR. d/ INDICATES GROUND CONDUCTOR. �2 NON-METALLIC SHEATHED CABLE 12/2 CU WITH GROUND f 3 NON-METALLIC SHEATHED CABLE 12/3 CU WITH GROUND 11"n FLEXIBLE RACEWAY, PROVIDE GROUND CONDUCTORS PER NEC. —�•- A-1,3 ADJACENT TO ARROW INDICATES HOMERUN OF CONDUCTORS IN CONDUIT FOR CIRCUITS 1 AND 3 TO PANEL "A". ® EXIT LIGHT WITH BATTERY, UNIVERSAL MOUNTING. EMERGENCY FLOODLIGHT WITH BATTERY. O LIGHT FIXTURE, SURFACE MOUNTED ON CEILING., 2 -LAMP, T8, WRAPAROUND, 64 WATTS LIGHT FIXTURE, WALL MOUNTED. {--� STRIP LIGHT FIXTURE. SURFACE MOUNTED OR CHAIN HUNG FROM CEILING. 2 -LAMP, T8,64 WATTS 0 DOWNLIGHT FIXTURE. LED, 15 WATTS FRE COPY WALL SCONCE, LED, 20 WATTS Permit Ho.� LANDSCAPE UPLIGHT, LED, 10 WATTS Plan subject to errors and omissions. Approval of consiruc;don documents doos not authorize 01 EXTERIOR, WALL SCONCE, DOWNLIGHT the violation of any adopted code or ordinance. Receipt of approved Field Copy and conditions is acknowledged: a POLE MOUNTED, LED, LIGHT FIXTURE ON 14'-0" POLE EXTERIOR, ROOF MOUNTED, DOWNLIGHT Date: , I-U,'-Gz 0 JUNCTION BOX. City of TukvWla BUILDING DIVISION POWER PANEL DUPLEX RECEPTACLE 20A, 125 VOLT WALL MOUNTED AT 18 INCHES AFF. G = GROUND FAULT INTERRUPTING, T = TAMPERPROOF. DUPLEX RECEPTACLE 20A, 125 VOLT WALL MOUNTED HORIZONTALLY 2" ABOVE COUNTERTOP BACKSPLASH TO THE BOTTOM OF THE RECEPTACLE COVERPLATE. FOURPLEX RECEPTACLE 20A, 125 VOLT, WALL MOUNTED AT 18 INCHES AFF. SPECIAL RECEPTACLE. AMPERAGE AND VOLTAGE AS SHOWN. EQUIPMENT CONNECTION. PROVIDE PER NEC AND MANUFACTURERS REQUIREMENTS AND/OR RECOMMENDATIONS. REVISIONS No changes -shall be made to the, scope of work %lithout prior -approval of Tukv1Ji!a Building Division. LUMI a MYupwsarW,Nw ,rrMYIADMMhMeY•iMY, fLOTE; RsviSivrm will require a ncUr plan submittal •■»�'��^-� x�1lLiara,aYwrAwr NlrMYr Y:IiEwW Oatlwww«rlrMrYN I` "^- ani may Il1�f11i�L'c^'..[fC�ifiinnal nlan rAuiauframe �.. c,.�,«Y,��,� w 4 o t ." 5i �'."y'r-'�•,,'f.���..��i., .. {���'' '.Y,u'4a i ` fki�� yyyyy ,iCt" vv `✓ .''4S �v ww.Ynwairw�Yy+IMM MM!-ri,4rniriN�7r'iYrr m,rb n 't� . � jjLM�1p�•aJi •w �1,�WK�radb� wn,'ww•e O ,t ' ' tICOs70 Ma'ww1 MN2• { _1VfWENIWlwT- .!� ,xar�wrwiwx'a ri_-, , ops wucr. a ... 2501/177 FiFVAm <.� U 1W u,o 1 A ELECTRICAL SYMBOLS LEGEND A DETAIL/SECTION IDENTIFICATION: A = DETAIL/SECTION LETTER, B = SHEET NUMBER B WHERE DETAIL/SECTION IS DRAWN. A EQUIPMENT CONNECTION CALLOUT. A,B EQUAL EQUIPMENT IDENTIFICATION ON B MECHANICAL EQUIPMENT CONNECTION SCHEDULES. VERIFY EXACT EQUIPMENT REQUIREMENTS ON SHOP DRAWING EQUIPMENT SUBMITTALS PRIOR TO ROUGH -IN. DO NO ROUGH -IN FOR EQUIPMENT PRIOR TO REVIEW OF SUBMITTALS. REPORT ANY DIFFERENCES IN REQUIREMENTS TO ENGINEER IN WRITING. CONDUIT CONCEALED. HASH MARKS INDICATE NUMBER OF #12 CONDUCTORS IN CODE SIZE CONDUIT. NO HASH MARKS INDICATES 2412 CONDUCTORS PLUS GROUND IN 314" CONDUIT, LONG HASH MARKS INDICATES NEUTRAL CONDUCTOR. d/ INDICATES GROUND CONDUCTOR. �2 NON-METALLIC SHEATHED CABLE 12/2 CU WITH GROUND f 3 NON-METALLIC SHEATHED CABLE 12/3 CU WITH GROUND 11"n FLEXIBLE RACEWAY, PROVIDE GROUND CONDUCTORS PER NEC. —�•- A-1,3 ADJACENT TO ARROW INDICATES HOMERUN OF CONDUCTORS IN CONDUIT FOR CIRCUITS 1 AND 3 TO PANEL "A". ® EXIT LIGHT WITH BATTERY, UNIVERSAL MOUNTING. EMERGENCY FLOODLIGHT WITH BATTERY. O LIGHT FIXTURE, SURFACE MOUNTED ON CEILING., 2 -LAMP, T8, WRAPAROUND, 64 WATTS LIGHT FIXTURE, WALL MOUNTED. {--� STRIP LIGHT FIXTURE. SURFACE MOUNTED OR CHAIN HUNG FROM CEILING. 2 -LAMP, T8,64 WATTS 0 DOWNLIGHT FIXTURE. LED, 15 WATTS FRE COPY WALL SCONCE, LED, 20 WATTS Permit Ho.� LANDSCAPE UPLIGHT, LED, 10 WATTS Plan subject to errors and omissions. Approval of consiruc;don documents doos not authorize 01 EXTERIOR, WALL SCONCE, DOWNLIGHT the violation of any adopted code or ordinance. Receipt of approved Field Copy and conditions is acknowledged: a POLE MOUNTED, LED, LIGHT FIXTURE ON 14'-0" POLE EXTERIOR, ROOF MOUNTED, DOWNLIGHT Date: , I-U,'-Gz 0 JUNCTION BOX. City of TukvWla BUILDING DIVISION POWER PANEL DUPLEX RECEPTACLE 20A, 125 VOLT WALL MOUNTED AT 18 INCHES AFF. G = GROUND FAULT INTERRUPTING, T = TAMPERPROOF. DUPLEX RECEPTACLE 20A, 125 VOLT WALL MOUNTED HORIZONTALLY 2" ABOVE COUNTERTOP BACKSPLASH TO THE BOTTOM OF THE RECEPTACLE COVERPLATE. FOURPLEX RECEPTACLE 20A, 125 VOLT, WALL MOUNTED AT 18 INCHES AFF. SPECIAL RECEPTACLE. AMPERAGE AND VOLTAGE AS SHOWN. EQUIPMENT CONNECTION. PROVIDE PER NEC AND MANUFACTURERS REQUIREMENTS AND/OR RECOMMENDATIONS. REVISIONS No changes -shall be made to the, scope of work %lithout prior -approval of Tukv1Ji!a Building Division. LUMI a MYupwsarW,Nw ,rrMYIADMMhMeY•iMY, fLOTE; RsviSivrm will require a ncUr plan submittal •■»�'��^-� x�1lLiara,aYwrAwr NlrMYr Y:IiEwW Oatlwww«rlrMrYN I` "^- ani may Il1�f11i�L'c^'..[fC�ifiinnal nlan rAuiauframe �.. c,.�,«Y,��,� w i Aa,>lt,?Ii1w ' 3 Yd.t10YW� i�IMiW DOB 20 t ." 5i �'."y'r-'�•,,'f.���..��i., .. {���'' '.Y,u'4a i ` fki�� yyyyy ,iCt" vv `✓ .''4S �v ww.Ynwairw�Yy+IMM MM!-ri,4rniriN�7r'iYrr F twr9 MM.Y •Hlyw 't� . � jjLM�1p�•aJi •w �1,�WK�radb� wn,'ww•e � w ,t ' ' tICOs70 Ir OA Broroe► ��' , ' t .,ti►yyyirn4�yr1ld.Jy,4rrit•+wwA ��+fearN.�rwa WW.wi{rYrllr.p.i IYYOrwtIM � clix w a«ywrwl,..rr.ranw it}U4 hwMR� � ylwry z 4 t • C rwt sew iEa w/.�ww.+rwMANW.Mw,Irti,1 Mw1«wlwaMhlw I- i I :wa.w.,,Ywwt'wV rY k k O. D. YarrYYww`�wrW�r4e�in �. r.. rrdrra !-rwrti rwrrw.O,gw,M a1M+wMwMwawarrw+r rWwrrwarrwYaN/M fl,wwrwMwiMrawnf 1w rrrwrrlwr IIY/Yww,11YY0M1wlnrra, ! �luiNr ` thwNwhft T«Mw�M-•Iw,ha. 1..M.Iw I«NYaeea,rarrlw«w nwiYrpalflrrrriY[ - xrrwwu/+MYrwa+www wYwnru++weunwr GnWwwMrlrMw'e rwlw,rnrN YYrxwM M YwrwwaaNyr ,Y,I MFYYn INMwwrp wYlr 4 �wr>r wwaM/wlrllar, rrrlellMr. ♦•..rlr,1«II . •TrV PMwl daowridnllrNCHl MurnoYv*Rh Mw►. • 1'A hwrw ata wAo/b4wA ani elw.tid b a roaW�Y MiA t�Y+r b p1►yY+C A OiaLtiwrd YNud •ar ..rj.µ..a "i&,l6.Affi'M-._. w nx1>. ^J«�Rx'ilxt,k� i!'_._._ £:,Y1Lt•+•.Jl.4!1lt.. 'n'C,^� u.. '"'r�'' rN.l wuMr avw-r m11.Mw+NrNrFu,lF+rrr qa rr.r I1� MfirbwntA MI�+c+avwwr w.M.+w. M. Two lUrl(wwtpot�w�w DwNSIt 00i:M hnapMwwba��rrMlwfir'�M MnpwwYw�x d�00'irT,ppwoaw wilCM�M w�Mr�Na sa riNl+MdtMn. tt+tM1Y.wwua txsu N�we r r-r4we W:ww•r• M7tw• arrVry++ww M.+iuMf Wtf�c�w+Ya�•y M�..;rM 4M �-Ww�••Y �H4N+in4My� aIiSMMN1tA�ee'•.�• rM4M b fir^ Ww�✓Owl U.rarwrwrxYiWY1W ,waUrwww wr{RwrMwr- Lre{"+lYa'wMaptldW lfwiclY�KArdldwrtabixYgMhble�: i ��•,,., �,` i Aa,>lt,?Ii1w ' 3 Yd.t10YW� i�IMiW wWAwr t ." 5i �'."y'r-'�•,,'f.���..��i., .. {���'' '.Y,u'4a i ` fki�� yyyyy ,iCt" vv `✓ .''4S �v ww.Ynwairw�Yy+IMM MM!-ri,4rniriN�7r'iYrr iw�w.«NArNw�11 W++�YrweaNWUr►Yr. twr9 MM.Y •Hlyw 't� . � jjLM�1p�•aJi •w �1,�WK�radb� wn,'ww•e � w +.Ow�drkl[ r+�lap.i,rix,4lraiwlrww w,4waraw+wrlwrrrtalw. rr11Ma1kwaYrrMirr w1y�w wwls fYw.t!lwew�147Atr, lllti•7M rra+..awArllaarrwr,r t .,ti►yyyirn4�yr1ld.Jy,4rrit•+wwA ��+fearN.�rwa WW.wi{rYrllr.p.i IYYOrwtIM � i �Y�tiN�wK'R4raY,pWriteM'w1,Ar.tS4i�fyaaMYwn/!. i . RMie4A.i.AplaJCwwil rrlwieauGglJw►wr w a«ywrwl,..rr.ranw it}U4 hwMR� � ylwry .w��y'i .CEI �i�.t���tii�++MM�rr�ii.lLtsidls+'yul, -- 555419D1��Ida.6/YptlM+1'\iww.'sdyMi 4 t • C rwt sew iEa w/.�ww.+rwMANW.Mw,Irti,1 Mw1«wlwaMhlw I- i I :wa.w.,,Ywwt'wV MMw.wwrwbr. •,Yr.,,ww.vYNrsYyexrwpY,. YarrYYww`�wrW�r4e�in �. r.. rrdrra !-rwrti rwrrw.O,gw,M a1M+wMwMwawarrw+r rWwrrwarrwYaN/M fl,wwrwMwiMrawnf 1w ewr rNwR rrrw h.w1e, xM. IF%+I- ._...�...�t....� .S•.Y..-..•l.. Vii_.. ±..a.. _�._...._.... wy ♦ YJ arrr pp 7A+J wW �•�—� Cwt^•\ �11rwt -sur: ••'_ W1A . _._.._ .. Mn.:' aw•k I W 0?" 1 Ulr w7.ri iwR:PtO� N A+Wl>i:Ct• � • _...... .... 0044 low W" fii ii a•t M8 MW i MM N ©.►,�. rMYa. 4r nr w+,•wl «d+t1u arlrw wwr r tat x1w' NN�wu. YrMW Ytl,1.leowraMYYrMrwltwbeanwanhrNYwM•yr w•nrwwr•M rr« Yx1YgAr1. rY1„wIMM IraY•M MiwKYbw ,}►�+'r+�•WriWiWwiyYneM Ne,wwr,www+�IMarr+awtwrrr iMlYnrwlOYMaW Yd.t10YW� i�IMiW wWAwr wwnpvrMMoy«wwrw. s*rw.l..www�w/.a1 ww.Ynwairw�Yy+IMM MM!-ri,4rniriN�7r'iYrr iw�w.«NArNw�11 W++�YrweaNWUr►Yr. /Iw«�MwM�MtWrgalww' wYYMMww�MnMw+Cwu Crx4arr.t1/1lcpwwrr MM/MIYYIIIYK kaarrarlW i�rauwYw«w wwl.Ni�lwwrdrwr «rwa�..w/uaau�«win r-wrrr1+rww w,4waraw+wrlwrrrtalw. rr11Ma1kwaYrrMirr araaWwwru.aa rwMurharrw:tarr fYw.t!lwew�147Atr, lllti•7M rra+..awArllaarrwr,r M Nt�M1Vri IYYOrwtIM � «rrwalrwrturwYraY► w a«ywrwl,..rr.ranw wwYwrw.rww.a��i1 w..a.1«ralwru.«.r ylwry //YIwiHY1Y+LiwrllwnlM .+w4i,.fiRfirhwW+. wW w/.�ww.+rwMANW.Mw,Irti,1 Mw1«wlwaMhlw rrwwrr,1rYtaawxuarww welt MMw.wwrwbr. YarrYYww`�wrW�r4e�in r -S." IlwwrryMYNwrudwlrM r.. rrdrra !-rwrti rwrrw.O,gw,M a1M+wMwMwawarrw+r rWwrrwarrwYaN/M fl,wwrwMwiMrawnf 1w rrrwrrlwr IIY/Yww,11YY0M1wlnrra, r«two �luiNr w.wNwr.a,gwwnwawlwrll T«Mw�M-•Iw,ha. 1..M.Iw I«NYaeea,rarrlw«w nwiYrpalflrrrriY[ - xrrwwu/+MYrwa+www wYwnru++weunwr GnWwwMrlrMw'e rwlw,rnrN YYrxwM M YwrwwaaNyr ,Y,I MFYYn INMwwrp wYlr r,piYtYYr► �wr>r wwaM/wlrllar, rrrlellMr. ♦•..rlr,1«II . •ar ..rj.µ..a "i&,l6.Affi'M-._. w nx1>. ^J«�Rx'ilxt,k� i!'_._._ £:,Y1Lt•+•.Jl.4!1lt.. rN.l wuMr avw-r m11.Mw+NrNrFu,lF+rrr qa rr.r I1� MfirbwntA MI�+c+avwwr w.M.+w. E N�we r r-r4we W:ww•r• M7tw• arrVry++ww M.+iuMf Wtf�c�w+Ya�•y M�..;rM 4M �-Ww�••Y �H4N+in4My� aIiSMMN1tA�ee'•.�• rM4M b fir^ Ww�✓Owl U.rarwrwrxYiWY1W ,waUrwww wr{RwrMwr- REVIEWED .FOR Mw.atrl wrwr«r. wrwwNar �•Y• •t' YMWi1eYw�i,►Y1.lMwrM.r City of'Tukwila � wa.wawA.Iw«w«w iri �1M• « �wnar stNara Zr rat xwsCN � N��"M� A LWwMIWIMYM .ems '+�• r 'Ce'rv" .e1.Iwwiwrnr�wMww a A00 wC[»II'3" +{ ,u ��i MIIW'a�Mwv�MK�iN�w ww, TMrN9wMM N*.K 204M NnMYw/w�iW�dM rM W rwtir111w Sw1..3�ri �,' Tr_- PERMIT F'E Uiw"fl FOR: La'MLchanicai Cl Electrical Plumbing -,as Piping Gly of Tukwila ��.R3F €?�fiQ� DIVI�tnl�l .1tl:NN:w` E}PEOfi�' 0., rr�it,w� raM1�e�Mw��+aM �r��r1�Mw11w/Y1111a111rwYw� � llrr{)wgrryl ••.wwar.r S LIGHT SWITCH TOGGLE TYPE, SINGLE POLE, SUBSCRIPTS; 3 = THREE WAY, 4 = FOUR WAY, D = DIMMER CONTROL, K = KEY OPERATED, P = PILOT LIGHT, a, b, c, ETC = NUMBER OF SWITCHES AT THE LOCATION AND SPECIFIC FIXTURES CONTROLLED. MOUNT AT 42 INCHES AFF. DISCONNECT SWITCH FUSED DISCONNECT SWITCH WITH FUSES. Sm MOTOR RATED TOGGLE SWITCH WITH OVERLOAD HEATER(S), SIZE PER NEC AND 0 0 SC (E) WP Kia�ai«ei� �, r.rw.Nw urtmsoot ,,.M«iHAAtK -'-- w.�icr°Iwrii°iwunxe arimw.N.wwcrtwww uwxa awnaa,Narrtun.m w¢pr pwye+r nwc w.rN,o. rw W»UKi,MN�1fOYNlN [wraxN wnnn�Nrere, wlrc,r W�?r/LT �NAf 1NWMNMiE iM VfOwJnl n11Mw1rR Nw.lwnCr: Nr«uwA.ew�/t�,wwn Nw r•T,{L n4wwuMfl «w r :Aw my}� w,rNr.x :rmwtr O¢kfKT L„tiuV.w*Nry w[atr ,n„NrlrnEl Btr U1 ��' �RNG wan �r 1hI �IRM•�Nb4 11NKM, bY�+hGf gWwOOtDNW I IMPACT ELITE SMALL -HID 2K fl Ste, CRIPTIQ14 (��j'�� 151 HIGH LIGHT POLE W/ LED LIGHT, •• \7/ sWSWGMrM i�#..}y��R YN/ IGM+I Vaiw i.i.fiM Y7.MsM t lb�ilOW {tt.«hrr MIwH'.Y DI•c'41»Ifa+O �wn• uv` t�oNsyt r..Ir.,wi«• vv�t,y"pauN 1W��py ori cwm waxm5• �NAtYbdww ' 0w1 xrs-Ime1 tkTrr/aWMYNM ie q.f IN waw-Ny r!t!'wr'i eyas!!,� __, _ awk owc r�rwrrvltu,wuw►.esr . wwa xa w.w >,e1N ; �ipwr�Yr�raIRIxIMw,•MT,M /•Oen��.{�a.Maiae�merwl><x1: .Y.tMw7"i' >.+4 D 7a.�Tuw,N� / wr.r �r'IGxM�M6aryWgr W� O�hrY�iu�t1'.t��V� ...�.. xx+x,wxtsw�ww„ww�wr.�t • iw1V:xVM+vw+�IwM•.�+t9wrN :9YW'aF.WrK nI1YrM�•� ilY7LPJ��Ir.FYNoM.baY 17MIw Ofwbk'a1MfY �y�OwhWrM�,h nttrnstw�'wY waF'44r IrMr• «aM�MYtwN-wLrM toww.RYwwl7CYfrOaO1[t 1711gwJ y�yyr� j iw,iwuwq ,.,r Glw rr.brwnyJyl lNfq r.•I. Ayw• ��wu. wNNtf W WNw[re.1*rrsvY,1. -t ! u 5ww•• GaYuwYR'� QYM900 1YtY Mw«M4::i`R7.�,IR �'•. VISA PLA.OW-2202. COLOR: BRONZE MOUNTING HEIGHT NOTED IS TO FIXTURE Y4wMY1a/ Qrnlr xw►w.p, Ir'S•'r"'-�......-.. •2t1 .XCM..+h+ r`r «wr•.wrlr.tr ' •ar ..rj.µ..a "i&,l6.Affi'M-._. w nx1>. ^J«�Rx'ilxt,k� i!'_._._ £:,Y1Lt•+•.Jl.4!1lt.. rN.l wuMr avw-r m11.Mw+NrNrFu,lF+rrr qa rr.r I1� MfirbwntA MI�+c+avwwr w.M.+w. N�we r r-r4we W:ww•r• M7tw• arrVry++ww M.+iuMf Wtf�c�w+Ya�•y M�..;rM 4M �-Ww�••Y �H4N+in4My� aIiSMMN1tA�ee'•.�• rM4M b fir^ Ww�✓Owl •a+wrrr ..k n�wrrr..•..� r wu N«.rrr:-ww.rwr aawu�.N�i{{�r M+.nNr b au a..r+.:awwwww..Glilr.r.Fr--ra, M.F. NMr.WrM �Naw.i�r •:ffw rM.wtiwMrM+..r. r.r,WWW r. rIw.N.Mal—n.'...rr.NYWSJi«I�K.MS+vwr Mw.VwsaY lrMrfrrTMtKw+.r Mrrs..r.n. ryrrrr.wr-.rww •/wwe••4 REVIEWED .FOR COMPLIANCE WITF NFPA70 - NEC JAN 19 2017 J 2:> wi� City of'Tukwila BUILDING DIVISION J! RECEIVED �;. f i Y OF `I`DKMA DEC 19 2016 LIGHTING LEGEND: 2K fl Ste, CRIPTIQ14 (��j'�� 151 HIGH LIGHT POLE W/ LED LIGHT, •• \7/ N vISIONAIRE PREMIER I w/ 4- DIA. ROUND' NON-TAPERED STEEL POLE AND DCB 20 DECORATIVE FLUTED CAST ALUMINUM POLE BASE. COLOR: BLACK �E LANDSCAPE UPLIGHT. LUMIERE CAMBRIA 203 1OW LED, STAINLESS STEEL D WALL -MOUNT LUMINAIRE, MCGRAW-EDISON IMPACT ELITE SMALL. COLOR: BRONZE MOUNTING HEIGHT NOTED IS TO FIXTURE CENTER. WALL—MOUNT SCONCE DOWNLIGHT. VISA PLA.OW-2202. COLOR: BRONZE MOUNTING HEIGHT NOTED IS TO FIXTURE CENTER. REVIEW SUBMITTAL v' r mawmam �x r ti hx U 0 z �� H 0� LO M _ J ,O N oz wL0 F ---I E z o w U'] °' 0 U) Q 2 � U /1 oma° t4�Y iz� I �Si�i�SY iy(is�Iti4I a s�tl�<t,�' ltl '�I at �� IIS I�iti� t; ��"�i° IlYlf>i1j1s1, �rtt11�j6 t a�t��t��r fl{� Il�i�1r+ LJJ Z J W LU 0 W W J _ 0 Lu .J J X D cv z D f— W (J J J LLI REVISIONS: 0029060 w DIST izn4�i6 SCALE: AS NOTED DATE: SHEET 12-14-16 DRAWN JAE CHECKED BY: El 00 SLH/GLW JOB NO.: 0 16-072 - - N • INC" me O U) n O D pm N I� E 0 O Ln '.•i Q0 O Til over s stWOa and 911 Ri (Project Title: Tukwila Bldg. E Number of Fixtures Date 12/9/2016 Calculation Area NOTE 0 stand 0 Addition existing faalone e 0 Spaces where c 60% of 0 Spaces where 2: 60% of n lumiraimes ars replaced luminaires ars replaced 2 -Lamp, TS, itrip Light Building Department Use LPA Calculation IType Standard Addllfanal Efflclanoy PsckageOption 0 0406.3 Reduced Interior LigMrg Power To complyWih 0406.3, the Proposed LAD shall be 25% lamer than the TaWt LPA. Refsr to C408,3 fbr additlonalraquiremants. a3dmum Allowed Lighting Wattagon 9 LED Exit Sin 5 Bullding Area Location (plan #, Gross acorn #ti or ALL) Area Description interior Area in ftp Allowed WSURAJ10WOd Watts per ff (wattsiff x area) Parking :arae Parking Gaga a 36300 0.1+6 5808 Multifamily Multi -Family 105oo0 4,41 43050 Multifamily 2 -Lamp, T8, Strip Light 30 64 1920 Multifamily LED Downil ht 276 15 4140 Multhmity LED Wall Sconce 124 20 2480 Toiall 141300 Proposed Lighting Wattage Building Area Location {plan #, room #) Fixture DescriptionNoTE 2's' a. s Number of Fixtures Watts per FbdureNaTa s Welts Proposed Parking garage 2 -Lamp, TS, itrip Light 82 64 5248 Parkin are g LED Exit Sin 5 3 15 Bldg. Fspeds I LED Wall Sconce 45 1 .20 1 980 Multifamily 2 -Lamp, T8, Fluorescent Surface Mount 86 64 5504 Multifamily 2 -Lamp, T8, Strip Light 30 64 1920 Multifamily LED Downil ht 276 15 4140 Multhmity LED Wall Sconce 124 20 2480 Multifamily LED Exk Sign 20 3 60 Muithrnlly I LEDDownlights - 'Unit 451 15 6765 Multifami 2 -Lamp, T8, Fluorescent Surface Mount - unit 1 126 64 1 9064 ,Multifamily 24 -am , T8 Fluorescent Van - Unit 1 131 54 1 8384 Compliiance by Building Area 10 ra a Building Area Warnings Total Allowed Watts Total Proposed Watts Interior Lighting Power Allowance Parking garage is 0 Addition- 0 Addition stard alma + eAdng 0 Alteration with < 80% 0 Alteration w1th ;t 80% 94 ext wattage replaced wattage replaced Boos 5263 COMPLIES Multifamily Surface Description 43 350 3731.7 COMPLIES Bldg. Fspeds I LED Wall Sconce 45 1 .20 1 980 Note f -List all unique building areas per Table 0405.4.2(7) that occur In the Tolglal 48958 42SOO p4act scope. Selaotbullding ama category ftmr drop down menu. Dote 2 - Proposed fixtures must be listed in the building ares In v4hich May occur. List all proposed llghiing fixtures Including exempt lighting equipment and exlsting-0-ramaln fires. Taste 3 -For proposed Fixture Description, Indicate fixture type, lamp We (e.g. T-8), numbaarof lamps In the fixture, and ballast type of Included), For track llghtlng, list Me length of the truck On Peso In addMon to fha ktule, lamp, and baliastlnformafion, Neta 4 - For lighting equlpmenfeligrible for examptlon per 0405.4.1, nate excapdan number and leave WaftFixiurs blank, Note 5 - Existing- ms1n fixtures shell be tnoluded in than Proposal Llghiing Wattage table In the same manneras new fixtures. Identify as existing In fixture description, MrJa A. IMF rur►fhser annmvmrl �nruPm prale# Title: Tukwila Bldg. E Data 12/9/2015 EJderlor L ghting Zone Table 0408.65.2(9) spara�edby jrArladicilon. 0 Zorn! 1 10 Zone 2 0 Zone 3 0 Zona 4 ;Zone seik'on requitod to Tenable LT(?-EKTbm For Building Department Use Calculation Area is 0 Addition- 0 Addition stard alma + eAdng 0 Alteration with < 80% 0 Alteration w1th ;t 80% 94 ext wattage replaced wattage replaced Building Grottmd8 Applies to luminaires y 100 waft 0 Efflcacy 8t? lumensiwatt D Exemptlan Montralled by motion sensor Tradable Maximum Allowed Lighting Wattage " , Base Site Allowance: soo Tradable Surfaces Surface Description Area , perimeter (tf) or # of Herne ;03l0w&Q 716,14 All MUG par fl? or per If x e {or x 10 650 Bldg. Fspeds I LED Wall Sconce 45 1 .20 1 980 rctal proposed imdaable wits may not axwed the sum oftlel allmod tradable Total Proposed Tradable Watts matte nlus tha bass aft allownce. Anv bass site ellamnca not naadad 1b i Total Allowed Tradable + Site Allowance Wa : 6001 Tradeable Proposed Lighting Wattage "II Tradable Surface NOTE � a Fbdure Deseriptien Number cat Fixtures s per Nota a Fixture Watts Proposed Aftw6dwattl per fe or per If AJIDWOU x fl? (or x 1) Bldg. Papde Building Perimeter 14800 0.1 W/f t:2 1480 10 65 1 650 Bldg. Fspeds I LED Wall Sconce 45 1 .20 1 980 rctal proposed imdaable wits may not axwed the sum oftlel allmod tradable Total Proposed Tradable Watts matte nlus tha bass aft allownce. Anv bass site ellamnca not naadad 1b i make badablo uetfs complycan be appilad to Individual Tran-tradabla N n;lra,dabire Maxim= A110wi0d Lighting W'a ""'" f�a�e Site Allowance Remaining: 600 Non -Tradable Surfaces Surface Description Area ), perimeter (it) or IN of items Aftw6dwattl per fe or per If AJIDWOU x fl? (or x 1) Bldg. Papde Building Perimeter 14800 0.1 W/f t:2 1480 10 65 1 650 Bldg. Fspeds I LED Wall Sconce 45 1 .20 1 980 soon-srav#avie irvputoesa Lighung vvaicrage - -- Non-Tradabla Surface Fixture Description N01%3. r Number of Fixtur€rs Wars per FixtureNataa Watts pied Bldg. Fagade LED Landscape Light 12 10 120 Bldg. Fv4adds, I LED Pule Mounted Light 10 65 1 650 Bldg. Fspeds I LED Wall Sconce 45 1 .20 1 980 Non -tradable proposed votts may, not exceed allowd vieffe for any lndlWdual Non -Tradable Watts Exceading0A: 270 suribcs unless the total excess %alis fir all non-fradable, suntces are lass titan Remaining Site Allowance: 330 the remainingalto alrcauanco Exterior L ghfing COMPLIES WITH MAX. ALLOWANCE Note f - List all unique exterior sulacss ,per rable C40542(2) that occur In the project scrape. Salad exterior suAcs caatego0as ffrtm drop dowi menu. Nato 2 - List all pmposad lighting fixtures Including existing-bomaln fixtums, Maio 3 - For proposed Fixture Darschptian, Indicate f7xlurre type, lamp We, numbsr of lamps In the fi'xturs, and ballast 4 pe (If applicable). Nate 4 - Ex/stfng maaln fixtures shell be Included in the Tradable and Nora-Tradebie Pmpic d Lighting Wattage tables In the same manner as now fixturea. Identify as existing In fixture desodpfion. Nate 5 - ftrpruposed WWWF'Ixtun3 anter the iuminalre mliage for Installed iarnp and ballast using rnanuiacturer or other approved source. For Iuminalres vithh scream lamps, enter the marnufacturar's Itstsdmaaxlmum Inputwitage of the fixture (neat the lamp raetfage). Forlow h -- R11"offi JAN 19 2017 OF I*UkWILA DEC 19 2016 P,ERFAIT CENTER REVIEW SUBMITTAL tb. t� f. #�g f Y 3; I �t� yygg } ti� At r � 00 T 1- I� (n cn \ L r N M N M v E WO Z W a rrF—I E O A O a) C V J Q > N C > cn 2 O 4 `� E @� U 0 CD LU a> W L m LUz W CD co z —17 J REVISIONS: JAN L' h'G 0029080 Qz ONAL 12/14/!6 SCALE: AS NOTED DATE: SHEET 12-14-16 DRAWN JAE CHECKED BY: El 01 SLH/GLW JOB NO.: OF 16-072 w4 zO m C� I E ch 4 cD 0 U a� 0 Al L I(ol;`L SITE P'LAN N SCALE: 3/32"=1'-0" 17) REVIEW SUBMITTAL �n av„ p#. "I u t { s ��r z �a r,. Si- R l i§H t y p n V co u� T 1- C Lo i1 M Lo N N L E W o z WL Q iV) E CD �WCD w � C cp 00 Q cp 2 co (uL) �l � � uO �1t�t>�k2 i tt4ib3�. I ,1 h,t i l� J ujLu LL J V I— I U ry � U W W REVISIONS: ��NL'tiG co y � 0029060 w o�Fss ONAL SCALE: AS NOTED DATE: SHEET 12-14-16 DRAWN JAE CHECKED BY: El 02 SLH/GLW JOB NO.: OF 16-072 - 10 w Q0 Q0 O C) 0 D FA ni n r9) SCALE:LEVEL I LIGHTING PLAN N ,, REVIEW SUBMITTAL A 0 ti; � iY t fn 9y. k f a T' y fk I zt 8h U co M �E N o z W0 IV E U WaD am 0 0 O 2 0 E U 0 �� F�t�� t�'ttlf �t�'tYliikkt'ylrt�}l+tjj i A 71 � i,41r kF�tn, W z J U z .J JJ W W J REVISIONS: vEN��yG 0029060 v�Fss NAL SCALE: 1zi14i16 SCALE: AS NOTED DATE: SHEET 12-14-16 DRAWN BY: JAE E200 CHECKED BY: SLH/GLW JOB NO.: OF 16-072 - - - A - - F - - - - - - - - - -� I A.5 I-5 11 B 0�11-3 -3 - v r----------- r -----------r I I I I I r------------ I I I DA= n 0 O oE1- i i E1- ---� RESIDENT LOBBY E1-51 OE1-5 OE OFFICE E -3 E -3 ^E1-3 L.J xy- E\ _-- 1L_ ------------7 ------------- , I B.2 I I I - E�1=9 -- -_ ---J -- E1-3 E1 3 �I! I - - I 2 BED -M 71 i I I � I I I I B B.31 �� E1 -1 O E1-1 E1-1 E1-1 - - O O O E1-5 \E-1 5 E1-5 \ \ E1-5 ?1-CE1 55 0---- o------ o- -� o E1-,5 LOBBY LOUNGE EJ -5 ELECTRICAL ST�I"- EO 11 F2 BED -M - \ I I - -I I \' I I \ \ CORRIDOR E1 E11-11 E? -1 E1-1 E11-1 E1 1 �i ��) T LEJ EI -1 E1 1 - �� ' 2 BED -M �' I - 1 - E1-1 u FIRE COMMAND E1-1 E1-1 D O SPRINKLER/ I I E1-3 m E1-3 -MAI -RIDO � E1-3 D E1-5� E1-5 BOILER E1-1 D EO < E1-3 D E1-5 - ACH. RM E1-1 0 E1-1 In _ 1 B.60 i I o' ' 0 E`t Ef-5 �1-5 ----------------i GARAGE LOB 0 0 E1-5 E1-5 3 Y 0 E1 -5 � E1 .6 � E1-5 � \ \ I _\ I , o 0 0 0 0 o E1-1 E1-1 E1-1 E1-1 E1-1 E1-1 01- L191�E1-1 LOBBY E1-1 0 o E1-1 f1- I I B.6 1 \� E1-1`- E1-1(� c CA - - ' IE I i -9E1-5 COMMERCIAL 1 coon 509 SF C1-1 14\ ID \. E11-5 \ E 1-5 TRASH RM \ E1-5- ` I -7-771 L L L L L L L \ - - - - - E1-6 E1-6 E1-6 E1- D D D E�1-6 \ E1-6 E1-6 O p � � _ c C41 L L a� -------- - E1-6 E1-6 E1-6 I E1-6 O I O I C2 -11 cg) - COMMERCIAL 2 L _ r- E1-9 I I _ - coot 682 SF E0 E1-7 O -E1-6------E1-6--EI-13 O L L L� L J o —E1--6------E-1-6--—--—E-1-6-- E1-6 ;� I L LJ L LJ li \ E1-6 Eh- =o 0 O E1-8 0 E 0 �- E1-10 C3-1 �L I I I El -96-1 I I NEIGHBORHOOD POLICE RESOURCE C4_1 CENTER 2065 SF \ 1-7 E1-7 1-7 1-7 E11-7 E EDE1- - 1-7 PARKING 1-7 Er1-7 � E1- GARAGE ED E1- i j E Er E11-8 E11-8_8 EQ -8 E1Q-8 E1-8 E1-8 E1_ D � E1-8 -ER i E1-8 E1-8 \ _ , E1-10 COMPLIANCE WITH NFPA 70 - NEC JAN 19 2017 Ci't of Tti llI E1-10 BUILDING I,IV181,0N E1© \ \ ` E I� EE1_-77 L E1- E7=3 0 STAIR 1 E1-7 /\ ---------- --- 1 I -L9 E1-9 E1-10 I �\ E1-8 E1-8 STAIR 2 � 11 o --- -� _ \ — - -- --- -- - II]m ON \ 1-10 - 1 1 1- 0 --- E10 E1-10 E1 E - 'OF TUi-QVIL I I \` —--- -----� DEC 192016 COMPACT COMPACT COMPACT COMPACT COMPACT CO OPACT COMPACT 12 3 4 (4.2) (4.5) (4.7) 5 5.1 (5.3) (5.5) (5.8) 6 7 8 9 PERMITCEN'TEI SCALE:LEVEL I LIGHTING PLAN N ,, REVIEW SUBMITTAL A 0 ti; � iY t fn 9y. k f a T' y fk I zt 8h U co M �E N o z W0 IV E U WaD am 0 0 O 2 0 E U 0 �� F�t�� t�'ttlf �t�'tYliikkt'ylrt�}l+tjj i A 71 � i,41r kF�tn, W z J U z .J JJ W W J REVISIONS: vEN��yG 0029060 v�Fss NAL SCALE: 1zi14i16 SCALE: AS NOTED DATE: SHEET 12-14-16 DRAWN BY: JAE E200 CHECKED BY: SLH/GLW JOB NO.: OF 16-072 - W V) O m ICK ., M• z� � .. I CA A.5 CB B.2 M., IN C.4 IN IN CF N n i>> 19 2017 FTuk�ila 1ECEI ED 'OF WKWILA DEQ 19 2016 IMIT CENTER REVIEW SUBMITTAL — - = - - -_ - - - -- - H111111111111 III Hill B.3 i A B � - o METING 1 1 E1-1 RM E1-17 E1-17 ��\\ El -17 STAT tt -- FE1?2o 10-2(DEl?0 0/0 JELI E1-17 E1-1 STR_ E1-17 EV 0 E1017 El -17 E1-17 MEM /\ /� ( / / \ _ _ IRa DD DD E1-20 - 2 E1- �o on r- E1-20 E1=20 E- - o oE1- -0 - -20 E 1-20 o E1-20 LE LOBOBY -20 E1-17 0E -17 0 Eo-rI�,�E1-107 NINE LOBBY E1-17 STOR. STOR. 0 E1-23 STOR. 0 E1-23 STOR. 0 E1-23 STOR. 0 E1-23 STOR. 0 E1-23 STOR. 0 E1-23 STOR. 0 E1-23 TOR. 0 1-23 STOR. 0 E1-23 STOR. (,E o E1-23 El -23 E .. 2� �� \ L IL L L L L fL MECH C - < - - - - - - - - - - - - - - - - - - - - EO E-23 E-23 E - ���ti� �vU����� �� ��w� �, �u� �� �� �w �����w� E - - - - E - - - - E l MEZZ. GARAGE v� a -2l �� E1�-23 \ C.4 / _ _ / \ Ila E1�-23 El -23 E©1 E1�-23 I El -23 E1-23 E1-23 E1-23 E1-2 E 11-21E1-23 E1-23 o 0 0 0 D / \ / / - JAN pity BUILDIN HEl E -24 IL -j i E1 IAI a F 24 PEI 19 2017 FTuk�ila 1ECEI ED 'OF WKWILA DEQ 19 2016 IMIT CENTER REVIEW SUBMITTAL W Q cn O D m D m N O zo I E n LO u Q0 O N U N N -O 11 SCALE:LEVEL 2 LIGHTING PLAN , 5F If U KOLA :' 19 2016 TWIT CENTER REVIEW SUBMITTAL a m O N W N O Cal 0) D m 0) N O zal Q0 r� N LL E Q N LO d' Qo O N U O n N -O lil LEVEL 3 LIGHTING PLAN N SCALE: 3/32"=l'-0" E cF1.v11F0G OFT UKOLA Elu' 19 2016 PAIT CENTER REVIEW SUBMITTAL W Q D O D m KA zi / O iT E n N Ln d - I QO O N U N Il CENTER REVIEW SUBMITTAL W Q cn 0 NEW D m V) 0 N O QO Qo z i7 E C N LO rrI QO T— O N d- U Q) n a LIGHTINGLEVEL 5 was re�bA1�1'� CAD COMPLIANCF.WITH FPA TO - NEO JAN 19 2017 Cid ®� �T�6�ila s a.��ABB H EP., E I V - t"j CITY OF 'j*UKMLA DcC 19 2016 PERMIT CENTER REVIEW SUBMITTAL W O m zol w N 0 Q0 O n 0 D NA n 110 Ln u It A7 ni n2 (3) n4 (5) C6 n n n LEVEL I POWER A ' 1A I"FzRM9'T CENTER REVIEW SUBMITTAL - - ----------- --- --- -- - - -�- 4 r-- A' - \ A.5 - - i B i12 - - E-13 E1 - r- -- ---------- r-- -- --------- _ ---f ---------- I - - A_ E-1=12rJ x i Fj - - -- --- --- -- -- - - - - i - - -- - RESIDENT LOBBY - OFFICE i i E1-4 ! - u - -----------� ------------ - i i \ B2 i - O 0, 11-7 --------------- � � LOBBY LOUNGE Nn 1< E1-13ION ELECTRICAL 2 BED -M -- - - _ - - I I �� q� (I I I .� -- mTE3.07 � � CORRIDOR E1 4 E1-4 - - 7 � � E1-4 2 BED -M � I B B.31 3 E1-2 EF 2 E1,2 f I - _ - i 2 BED -M , - _ E1-2 S FIRE COMMAND RINKLER/BO A PR AIL ROOM El -4 M. I 1 STAIR 3 1 1 1 I MACH. MACH.RM LE E C. AH E1=2 _ E14 i I B 6 �- --- O � ; 11; � E1-11 i L � E1-4 LOBBY u, \7\ H1' � 1- �\ I I `o _ �� E1-4 E1-4 STAIR a 8 ® HPE 2 LOBBY E1-2 Lu \ o I B.61 C.4 �3� - AH HP1-3 !GARAGE C C.4 �- � --- COMMERCIAL 1 C003 509 SF AH 1 C1-2 PANEL Cl HP1-7 TRASH \ COMPACTOR TRASH RM L L L L L - -- -- ------ -- -- --- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - ------------ - - - - - - - - - - L L� ---------- - - - - - - - - - - - - - - - - - - - - - I I - - - - - - - - - - - - - - - H 1- C2-1 PANEL C2 AH 2 C2-2 D._ L r- - COMMERCIAL 2 682 SF I I - - - - - - - - - - - - - - - - - - - `, ---— ——---- —- lavd�^�oa yard oo �O-jdoa - - - - - - - - - - - - - - - - - - — -- — —— -- -- -- --`, I — -- — — — — — \ 0 0 PANEL C3 AH 3 C3-2 L 0.0 F_ - - - i i CAc PARKING GARAGE - - - - - - - b�J Uln�l0a �*VdC/1400 iLovUVllC a \ � \L I I L — I J 0- I 0 Ooh I / I _ , — - _ REVI4®.F®R COMPLIANCE WITH NFPA 70 - NEC JAN 19 2017 ® �ety ®f Tek ila AH PANEL C4 4 C4-2 C4-1 NEIGHBORHOOD POLICE RESOURCE CENTER 2065SF -- ----- STAIR 1 .- G IL--------------- -- LJ LJ LJ _ oDvdwl\ 0 a 'UC'�= � E i L-- o STAIR 2 RATOR F j — E1-8 _.—_—_--- — --LJ RE(11EI v CITY OF l'UKW COMPACT COMPACT COMPACT COMPACT COMPACT CO PACT COMPACT - - - - - - - - 1 2 3 4 (4.2) (4.5) (4.7) 5� 5.1 (5.3) (5.5) (5.8) 6 (�5 g g DEC 191A16 .. �) II .�11-11 LEVEL I POWER A ' 1A I"FzRM9'T CENTER REVIEW SUBMITTAL w O D zi q LN Q0 1 n Ln d - I CD 0 U N n Ill C A.5 IN n CA IN IN CF 044 N r, n N `0 C.4 01 .V.IEWE® FOI� IPLIA CE WITH FPA 70 n ITEC JAPE 19 2017 '1' M: RECEIVED' CITY OF T UKWILA DEC 19 2016 PERMIT CENTER REVIEW SUBMITTAL E1-1 \ 77 AH — _ 1-15 E`9-14 Efl E1-16 MEET G RM � � STAIR 3 \ \ / \ / ---- \ \ / -- - \ \ / -- w E1 -20E1- E1-18 E118 - EF 9 RESTRM. EV �' ' \ \ \ f�_�' / \ \ \ \ / \ / / / \ Ll PUT \ \ / \ / / / \ LL _ _- M1=DIA #�M" AH �� �J D D 9 El D D D r- - _ E1-20 �' e�) STOR. STOR. STOR. STOR. STOR. STOR. STOR. STOR. TOR. STOR. OTOR. T7, - - -_ AH HP1-13 6 MEZZANINE E1-18 E1-18 - O LOBBY - 1cz 11 L / \ / / \ �� ST IR 4 E1-20 LOBBY I ELE 2� 11 33 CU l� E1- c HP2-4 \ \71 \ L LLLI� 1- \ �� MECH _= HP1-12 \ 11 w Jw� U v w � AU SUN Mu -� - - - - - - - - - - - MEZZ. GARAGE , a wu - , w _ - - H \ � v \ HP1-16 \kV,- SF C 1-3 ` G3-3 _ 0 oLi \ \ / lam Rl rii - -- suit Lj N `0 C.4 01 .V.IEWE® FOI� IPLIA CE WITH FPA 70 n ITEC JAPE 19 2017 '1' M: RECEIVED' CITY OF T UKWILA DEC 19 2016 PERMIT CENTER REVIEW SUBMITTAL w Q D V) O D zi m W CD N O M Q0 O N / U) C) O D / W N LL E Q d LO Cfl O N U N LEVEL 2 PhOWER'h PLAN m gal D m U) N O QO r.4 E d - Ln I CD O N U N n 4F O al 'IV/ / .,.. ,�,� 0 i OR /4 m" SCALE: ' OF I8 UKOLA cf'o 19 2 116 PERMIT CENTER REVIEW SUBMITTAL W Q D O D m m M N O MI I E n -t Ln d- Q0 O N O N Al SCALE:LEVEL 4 POWER PLAN N i of-Tuk ila JG DIVISION 1E.cE1.v n. 'OF MMLA. DtIL'* 19 2016 PERMIT CENTER REVIEW SUBMITTAL m ONE V zE O I E Q Ln Ln Qo O N d- U N C) Al LEVEL 5 POWER PLAN N 11- , 1 FIEVIE ED FOR COMPLIANCE WITH NFPA 7 - NEC JAPE 19 2011 city of Tukvdl CITY OF "i UI�� IL D� 19 2016 PERMIT Cr=NTFR REVIEW SUBMITTAL m zi D m cn 0 N O zo Q0 O N U) n O D / z a� I LO Ln CD O N U N 0 As fiEWE® .FOR ILIANCE WITH PA 70 a NEC �N 19 2017 LEVEL S POWER a... SCALE:AN N 3/32"=l' -O" e -%I— Y O -MMLA D � 19 2016 PERMIT CENTER w Q 0 MAI C Mol N Lm a 4 yy t 1 I r i f � f i I r E307 SCALE: 1/4"=1'-0"E307 'SCALE: A. P ELECTRICAL ROOM EQUIPMENT LAYOUT' 1/4"=11-011 -AEVIEWED.FOR'- COMPLIANCE WITH NFPA 70 - NEC J 9 2017 City of TukWla CIT if OF TU K0L DEC 19 2016 PERMIT CENTER REVIEW SUBMITTAL W Q D O D m 6 O w Mal Q0 O m E n Qo Ln :: 110, f U 0 Am UNIT 1 BED -A ELECTRICAL PLAN SCALE: 1/4"=V-0" UNIT 1 BED -C ELECTRICAL PLAN SCALE: 1/4"=l' -O" UNIT 1 BED -A1 ELECTRICAL PLAN SCALE: 1/4"=I' -O" UNIT 1 BED -C1 ELECTRICAL PLAN SCALE: 1/4"=1'-0" UNIT 1 BED -B ELECTRICAL PLAN SCALE: 1 /4"=1'-0" UNIT 1 BED -C W/D ELECTRICAL PLAN SCALE: 1/4"=l' -O" JAN 19 2017 RECERIT"I'D CITE' OF TUKWiLA DEC 19 2016 PERMIT CENTER REVIEW SUBMITTAL m FAI QO O N n O D II N IF n Qo Ln u I O N d - O O 0 211 UNIT 1BED-C1 W/D ELECTRICAL PLAN SCALE: 1/4"=1'-0" UNIT 2BED-E ELECTRICAL PLAN SCALE: 1/4"=1'-0" UNIT 1 BED -C3 /D ELECTRICAL PLAN SCALE: 1/4"=l' -O" UNIT 2BED-E W/D ELECTRICAL PLAN SCALE: 1/4"=l' -O" UNIT 2BED-D W/D ELECTRICAL PLAN SCALE: 1/4"=l' -O" UNIT 2BED-E1 ELECTRICAL PLAN SCALE: 1/4"=1'-0" JAN 19 2017 —o City of TukWiIj DECEIVED CITY OF TUKWIt. A DEC 19 2016 PERMIT CENTER REVIEW SUBMITTAL W Q U� O D m D m N O Qo it E Aar UNIT 2BED-El /D ELECTRICAL PLAN SCALE: 1/4"=l' -O" UNIT 2BED-M ELECTRICAL PLAN SCALE: 1/4"=I' -O" cl Ty OF- TUKWILA DEC 19 2016 PERMIT CENTER REVIEW SUBMITTAL 1° v ma, 3 0 Ln w rq 0 Lu to C m 3 N r- 0 0 l® 0 qA 0 z N m 0 v o 0 - TRANSFORMER PER UTILITY STANDARDS AND REQUIREMENTS TAP •J ■0 0 BOX 17,392 R-3 800A 5TH FLOOR 4TH FLOOR 3RD FLOOR 18,328 2ND FLOOR _ 1 ST FLOOR AVAILABLE FAULT - CURRENT, TYPICAL TAP BOX 806A '0'0 OVERALL BUILDING SERVICE LOAD CALCULATION °0 100A UNIT PANEL, -(g '0'0 TYPICAL OF 30. 0 °0 0'0'0 PANEL UP COMMERCIAL SPACE = 200 AMPS 16,547 R-4 sooA s,531 POLICE RESOURCE CENTER + 200 AMPS ■ M 100A • M ■ M 100A, 208V, 1 PH, PSE METER AND HOUSE LOADS + 200 AMPS 0.0 7 EMERGENCY PANEL LOADS + 400 AMPS �'@ RESIDENTIAL UNITS + 1600 AMPS CIRCUIT BREAKERS. TYPICAL OF 32. TOTAL BUILDING SERVICE = 2600 AMPS 0 °0 100A, 208V, 1 PH, PSE METER AND @208V, 3PH METER BASE WITH 100A/2 -POLE CIRCUIT BREAKERS. TYPICAL OF 30. �— TYPICAL OF 30. 2 100A UNIT PANEL, �— TYPICAL OF 32. PANEL UP UP 8,331 100A 8,582 TAP BOX 806A '0'0 -(2)1 0 °0 0'0'0 -(g '0'0 0 °0 0'0'0 '0'0 16,547 R-4 sooA 0'0 ■ M 0'0'0 ■ M M SERVICE GROUND #3/0 CU TO UFER,)o )o �oCD �o BUILDING STEEL,I °O I co I C0 I co OR WATER PIPE TAP Q) -(2)1 U'U (Dl -(g BOX 16,547 R-4 sooA • M OOOOO�O ■ M M ■ M M • M ■ M 100A, 208V, 1 PH, PSE METER AND METER BASE WITH 100A/2 -POLE CIRCUIT BREAKERS. TYPICAL OF 32. 100A UNIT PANEL,. �— TYPICAL OF 30. 2 PANEL UP 8,582 100A •®°®®'o o•0 7 TAP •O.O ®•O ®•CO BOX 2 17,617 800A °o °®®•o ®'® 100A, 208V, 1 PH, PSE METER AND METER BASE WITH 100A/2 -POLE CIRCUIT BREAKERS. TYPICAL OF 30. 100A UNIT PANEL, TYPICAL OF 33. 100A, 208V, 1 PH, PSE METER AND METER BASE WITH 100A/2 -POLE CIRCUIT BREAKERS. TYPICAL OF 33. I -I 2800A,120/208V,3PH,4W SWITCH BOARD GRD = PANEL E2 200A PANEL PANEL PANEL PANEL PANEL PANEL HP HP1 HP2 HP3 EM E1 18,328 8,193 800A 200A 200A 200A 400A 200A 2 POWER RISER DIAGRAM NO SCALE 400A, ATS CONDUIT AND CONDUCTOR SCHEDULE: A(9)4"C-(4)#600 KCM AL EACH A2(3)3"C-(4)#400 KCM & (1)#3/0 AL EACH A3(2)3"C-(4)#500 KCM & (1)#2/0 AL EACH 44\ 2-1/2"C-(4)#250 KCM & (1)#4 AL A5(2)2 -1/2"C-(4)#250 KCM & (1)#1 AL EACH /6\ #2 MC CABLE AL A#1/0,#1/0,#1/0,#6 SER CABLE A8#3/0,#3/0,#3/0,#4 SER CABLE A9#2,#2,#2,#6 MC CABLE AL A(1)1 " CONDUIT WITH (3)#6 CU & (1)#10 CU GRD (15 HP TRACTION ELEVATOR) 60A,208V,3PH FUSIBLE SHUNT TRIP ELEVATOR DISCONNECT WITH AUXILLARY CONTACTS. ELEV. #1 ELEV. #2 PANEL PANEL EL1 EL2 ,676 I I 60A 60A 60A,208V,3PH FUSIBLE SHUNT TRIP ELEVATOR DISCONNECT WITH AUXILLARY CONTACTS. \_ 15OKW GENERATOR 1, 1 m 0 O Ln w • a D m / W N O z. m Q F_ Ln :: 0 N 9 O N r_-) Il SURFACE MOUNTING PANEL SCHEDULE 42,000 AIC 22,000 AIC ELI LOCATION: ELEV. MACH. RM. SERVING: ELEV. MACH. RM. NO. HP LOCATION: ELECTRICAL RM. 1 120/208 VOLTS 3PHASE 4WIRE LOCATION: SERVING: HOUSE LOADS SERVING: 800 AMPS WITH MAIN LUGS CKT LOAD DESCRIPTION KVA TRIP NO. AMPS i TRIP KVA AMPS LOAD DESCRIPTION CKT NO. 1 PANEL HP1 60.90 200 200 61.20 PANEL HP2 2 3 20 3.82 SUPPLY FAN #3 4 5 3 3 6 7 PANEL HP3 13.70 200 400 131.80 PANEL EM 8 9 6 7 DF -1 DF -2 EF -19 10 11 3 3 12 13 SPACE 7 SUNROOM APP. CIRCUIT SPACE 14 15 2 3 16 17 13 TRASH COMPACTOR 18 19 14 15 20 21 2 16 22 23 1.29 20 24 25 15 SF -6 26 27 21 16 28 29 22 23 30 31 19 24 32 33 20 2.70 SF -5 20 34 35 2.70 20 36 37 29 18 38 39 30 31 40 41 SPACE 20 32 SPACE 42 REMARKS: 27 CONNECTED LOAD: 267.6 KVA 743 AMPS 34 35 DEMAND LOAD: 272.6 KVA 757 AMPS PROVIDE HANDLE TIES FOR ALL MULTI -CIRCUIT HOMERUNS SHARING A NEUTRAL PER THE NATIONAL ELECTRIC CODE ARTICLE 210.4 MULTIWIRE BRANCH CIRCUITS, PART (B) DISCONNECTING MEANS. DRAWINGS ARE DIAGRAMMATIC. WHERE THE CONTRACTOR MODIFIES THE CIRCUITING, THE CONTRACTOR SHALL PROVIDE AN INDIVIDUAL NEUTRAL PER CIRCUIT, MULTI -POLE CIRCUIT BREAKERS, OR CIRCUIT BREAKER HANDLE TIE TO MEET THE NEC ARTICLE. ALL COSTS ASSOCIATED WITH MODIFICATIONS SHALL BE INCLUDED IN THE CONTRACTOR'S BID. SURFACE MOUNTING PANEL SCHEDULE 22,000 22,000 AIC ELI LOCATION: ELEV. MACH. RM. SERVING: ELEV. MACH. RM. ELEV. MACH. RM. ELEV. MACH. RM. NO. NO. HP3 LOCATION: ELECTRICAL RM. LOCATION: 120/208 VOLTS 3PHASE 4WIRE 1201208 VOLTS 3PHASE 4WIRE SERVING: HOUSE LOADS SERVING: HOUSE LOADS 200 AMPS WITH MAIN LUGS CKT LOAD DESCRIPTION KVA TRIP NO. AMPS TRIP KVA AMPS LOAD DESCRIPTION CKT NO. 1 SUPPLY FAN #2 3.82;�3 20 3.82 SUPPLY FAN #3 2 3 1.32 20 20 1.42 4 5 L-4 CORR. LTS RECEPTS. 3 20 6 7 DF -1 DF -2 EF -19 1.32 20 20 4.75 EF -17 EF -18 8 9 SPACE AH -14 CU -14 6 7 SUNROOM APP. CIRCUIT 10 11 2 3 9 12 13 TRASH COMPACTOR 30 3.54 SPACE 14 15 1.45 9 2 16 17 L-5 CORRIDOR LIGHTS 1.29 20 18 19 15 SF -6 2.70 20 21 16 17 5.41 22 23 3 18 19 24 25 3 20 2.70 SF -5 20 26 27 2.70 20 30 28 29 18 19 16 30 31 25 20 20 32 33 SPACE 26 27 L-4 CORR. LIGHTS RECEPTS. 34 35 23 28 29 36 37 37 24 30 38 39 39 3 23 40 41 SPACE 41 1 SPACE SPACE 42 REMARKS: 35 ED LOAD: 13.7 KVA LDEMAND 38 AMPS 5.00 30 LOAD: 14.9 KVA 41 AMPS PROVIDE HANDLE TIES FOR ALL MULTI -CIRCUIT HOMERUNS SHARING A NEUTRAL PER THE NATIONAL ELECTRIC CODE ARTICLE 210.4 MULTIWIRE BRANCH CIRCUITS, PART (B) DISCONNECTING MEANS. DRAWINGS ARE DIAGRAMMATIC. WHERE THE CONTRACTOR MODIFIES THE CIRCUITING, THE CONTRACTOR SHALL PROVIDE AN INDIVIDUAL NEUTRAL PER CIRCUIT, MULTI -POLE CIRCUIT BREAKERS, OR CIRCUIT BREAKER HANDLE TIE TO MEET THE NEC ARTICLE. ALL COSTS ASSOCIATED WITH MODIFICATIONS SHALL BE INCLUDED IN THE CONTRACTOR'S BID. SURFACE MOUNTING PANEL SCHEDULE 22,000 AIC ELI LOCATION: ELEV. MACH. RM. SERVING: ELEV. MACH. RM. ELEV. MACH. RM. ELEV. MACH. RM. NO. NO. E2 LOCATION: ELECTRICAL RM. LOCATION: ELECTRICAL RM. 1201208 VOLTS 3PHASE 4WIRE LOAD DESCRIPTION SERVING: SERVING: HOUSE LOADS 1 400 AMPS WITH MAIN LUGS 200 AMPS WITH MAIN LUGS CKT NO. LOAD DESCRIPTION KVA TRIP AMPS TRIP KVA AMPS LOAD DESCRIPTION CKT NO. 1 L-4 CORR. LTS RECEPTS. 1.32 20 20 1.42 L-4 CORR. LTS RECEPTS. 2 3 L-4 CORR. LTS RECEPTS. 1.29 20 20 .90 SUNROOM RECEPTS. 4 5 SUNROOM APP. CIRCUIT 1.50 20 30 3.54 AH -14 CU -14 6 7 SUNROOM APP. CIRCUIT 1.50 10 2 8 9 L-5 CORR. LTS RECEPTS. 1.32 TRASH COMPACTOR 30 3.54 AH -15 CU -15 10 11 L-5 CORRIDOR LIGHTS 1.45 9 2 12 13 L-5 CORRIDOR LIGHTS 1.29 20 20 2.70 SF -4 14 15 SF -6 2.70 20 CU -5 12 16 17 5.41 30 2 3 18 19 L-3 DRYER 24 3 20 2.70 SF -5 20 21 SF -7 2.70 20 30 22 23 18 19 16 3 24 25 20 20 3 L-2 WASHER SPACE 26 27 L-4 CORR. LIGHTS RECEPTS. 1.32 20 23 28 29 SPACE 36 37 24 30 31 5.0030 39 3 23 32 33 41 1 SPACE 2 20 34 35 29 L-2 DRYER 5.00 30 36 37 INTERNET CAFE RECEPT. 30 31 L-4 DRYER 5.0030 38 39 1.50 SPARE 32 33 SPACE 40 41 SPACE 20 SPACE 34 35 SPACE 42 REMARKS:. L-5 DRYER 5.00 CONNECTED LOAD: 31.1 KVA 86 AMPS 36 37 L-5 DRYER 32 DEMAND LOAD: 32.3 KVA 90 AMPS PROVIDE HANDLE TIES FOR ALL MULTI -CIRCUIT HOMERUNS SHARING A NEUTRAL PER THE NATIONAL ELECTRIC CODE ARTICLE 210.4 MULTIWIRE BRANCH CIRCUITS, PART (B) DISCONNECTING MEANS. DRAWINGS ARE DIAGRAMMATIC. WHERE THE CONTRACTOR MODIFIES THE CIRCUITING, THE CONTRACTOR SHALL PROVIDE AN INDIVIDUAL NEUTRAL PER CIRCUIT, MULTI -POLE CIRCUIT BREAKERS, OR CIRCUIT BREAKER HANDLE TIE TO MEET THE NEC ARTICLE. ALL COSTS ASSOCIATED WITH MODIFICATIONS SHALL BE INCLUDED IN THE CONTRACTOR'S BID. SURFACE MOUNTING PANEL SCHEDULE 22 000 AIC ELI LOCATION: ELEV. MACH. RM. SERVING: ELEV. MACH. RM. ELEV. MACH. RM. ELEV. MACH. RM. NO. EM NO. HPI LOCATION: ELECTRICAL RM. KVA LOAD DESCRIPTION SERVING: 1201208 VOLTS 3PHASE 4WIRE 1 400 AMPS WITH MAIN LUGS SERVING: HOUSE LOADS TRIP KVA AMPS LOAD DESCRIPTION CKT NO. 1 200 AMPS WITH MAIN LUGS CKT N0. LOAD DESCRIPTION KVA TRIP AMPS TRIP AMPS KVA LOAD DESCRIPTION CKT NO. 1 OIS POLE LIGHTS .58 20 20 .14 O/S POLE LIGHTS 2 3 AH-7,CU-7 3.12 20 20 3.12 AH -8 CU -8 4 5 AH -12 CU -12 10 2 2 3 6 7 TRASH COMPACTOR 8.6430 4.60 60 60 11.19 AH -5 8 9 2 2 16 2 - 10 11 SPACE 18 19 3 30 4.16 CU -5 12 13 AH -6 5.41 30 2 23 14 15 L-3 DRYER 24 2 20 2.70 SFA 16 17 CU -6 3.50 30 2 28 18 19 16 17 2 3 20 20 21 L-2 WASHER 1.50 20 25 6.01 EF -1 22 23 L-2 WASHER 1.50 20 36 37 24 25 L-2 DRYER 5.0030 39 3 23 26 27 41 1 SPACE 2 20 1.44 INTERNET CAFE RECEPT. 28 29 L-2 DRYER 5.00 30 20 1.26 INTERNET CAFE RECEPT. 30 31 L-4 DRYER 5.0030 2 20 1.50 SPARE 32 33 SPACE 1.50 2 20 SPACE 34 35 30 31 L-5 DRYER 5.00 30 36 37 L-5 DRYER 32 33 3.54 30 38 39 AH -11 CU -11 34 34 35 SPACE 40 41 ISPACE 1.50 L-5 WASHER 36 37 SPACE 42 REMARKS: 20 1.32 CONNECTED LOAD: 60.9 KVA 169 AMPS SPACE 38 39 1.42 DEMAND LOAD: 65.7 KVA 182 AMPS PROVIDE HANDLE TIES FOR ALL MULTI -CIRCUIT HOMERUNS SHARING A NEUTRAL PER THE NATIONAL ELECTRIC CODE ARTICLE 210.4 MULTIWIRE BRANCH CIRCUITS, PART (B) DISCONNECTING MEANS. DRAWINGS ARE DIAGRAMMATIC. WHERE THE CONTRACTOR MODIFIES THE CIRCUITING, THE CONTRACTOR SHALL PROVIDE AN INDIVIDUAL NEUTRAL PER CIRCUIT, MULTI -POLE CIRCUIT BREAKERS, OR CIRCUIT BREAKER HANDLE TIE TO MEET THE NEC ARTICLE. ALL COSTS ASSOCIATED WITH MODIFICATIONS SHALL BE INCLUDED IN THE CONTRACTOR'S BID. SURFACE MOUNTING PANEL SCHEDULE 22,000 AIC ELI LOCATION: ELEV. MACH. RM. SERVING: ELEV. MACH. RM. ELEV. MACH. RM. ELEV. MACH. RM. NO. EM LOCATION: ELECTRICAL RM. TRIP AMPS 120/208 VOLTS 3PHASE 4WIRE KVA LOAD DESCRIPTION SERVING: STANDBY LOADS 1 400 AMPS WITH MAIN LUGS CKT NO. LOAD DESCRIPTION KVA TRIP AMPS TRIP KVA AMPS LOAD DESCRIPTION CKT NO. 1 PANEL E1 58.50200 200 29.80 PANEL E2 2 3 .31 MACH. ROOM GFI LIGHT CKT NO. 4 5 MACHINE RM. CONTROLLER 3 3 6 7 ELEVATOR #1 16.63 60 60 16.63 ELEVATOR #2 8 9 20 3.12 AH -12 CU -12 10 11 SPACE 3 3 12 13 PANEL EL1 4.60 60 60 4.60 PANEL EL2 14 15 1 SPACE 2 2 16 17 SPACE CONNECTED LOAD: 4.6 KVA DEMAND LOAD: 5.4 KVA 22 AMPS 26 AMPS SPACE 18 19 1.08 COURTYARD LIGHTING 10 20 21 1.53 20 20 22 23 12 13 L-3 DRYER 24 25 30A 5.00 L-3 DRYER 26 27 1.50 2 28 29 16 16 17 30 31 20 20 1.50 32 33 19 L-3 WASHER 1.50 34 35 5.00 L-4 DRYER 20 36 37 1.502 1.50 38 39 22 23 L-4 WASHER 40 41 1 SPACE 5.00 L-4 DRYER SPACE 42 REMARKS:. L-4 WASHER CONNECTED LOAD: 131.8 KVA 366 AMPS 20 2 L-2 LTS/RECEPTS. DEMAND LOAD: 136.9 KVA 380 AMPS PROVIDE HANDLE TIES FOR ALL MULTI -CIRCUIT HOMERUNS SHARING A NEUTRAL PER THE NATIONAL ELECTRIC CODE ARTICLE 210.4 MULTIWIRE BRANCH CIRCUITS, PART (B) DISCONNECTING MEANS. DRAWINGS ARE DIAGRAMMATIC. WHERE THE CONTRACTOR MODIFIES THE CIRCUITING, THE CONTRACTOR SHALL PROVIDE AN INDIVIDUAL NEUTRAL PER CIRCUIT, MULTI -POLE CIRCUIT BREAKERS, OR CIRCUIT BREAKER HANDLE TIE TO MEET THE NEC ARTICLE. ALL COSTS ASSOCIATED WITH MODIFICATIONS SHALL BE INCLUDED IN THE CONTRACTOR'S BID. SURFACE MOUNTING 10,000 AIC PANEL SCHEDULE N0. ELI LOCATION: ELEV. MACH. RM. SERVING: ELEV. MACH. RM. ELEV. MACH. RM. ELEV. MACH. RM. 1201208 VOLTS 1 PH 3WIRE 60 AMPS WITH MAIN LUGS CKT NO. LOAD DESCRIPTION KVA TRIP AMPS TRIP AMPS KVA LOAD DESCRIPTION LOAD DESCRIPTION CKT NO. 1 AC-E/CU-E 3.33 20 2 15 20 20 .31 PIT GFI LIGHT CKT NO. 2 3 TRIP ET AMPS TRIP AMPS .31 MACH. ROOM GFI LIGHT CKT NO. 4 5 MACHINE RM. CONTROLLER .60 20 SPACE L-2 WASHER 6 7 SPACE 7 2 20 3.12 AH -12 CU -12 8 9 SPACE .36 20 2 GARAGE LIGHTS 6 10 11 SPACE .54 1 SPACE SPACE .54 12 REMARKS: 9 CONNECTED LOAD: 4.6 KVA DEMAND LOAD: 5.4 KVA 22 AMPS 26 AMPS PROVIDE HANDLE TIES FOR ALL MULTI -CIRCUIT HOMERUNS SHARING A NEUTRAL PER THE NATIONAL ELECTRIC CODE ARTICLE 210.4 MULTIWIRE BRANCH CIRCUITS, PART (B) DISCONNECTING MEANS. DRAWINGS ARE DIAGRAMMATIC. WHERE THE CONTRACTOR MODIFIES THE CIRCUITING, THE CONTRACTOR SHALL PROVIDE AN INDIVIDUAL NEUTRAL PER CIRCUIT, MULTI -POLE CIRCUIT BREAKERS, OR CIRCUIT BREAKER HANDLE TIE TO MEET THE NEC ARTICLE. ALL COSTS ASSOCIATED WITH MODIFICATIONS SHALL BE INCLUDED IN THE CONTRACTOR'S BID. SURFACE MOUNTING PANEL SCHEDULE 22,000 AIC EL2 LOCATION: SERVING: ELEV. MACH. RM. ELEV. MACH. RM. 1201208 VOLTS 1PH 3WIRE 60 AMPS WITH MAIN LUGS CKT NO. NO. HP2 LOCATION: ELECTRICAL RM. TRIP AMPS KVA LOAD DESCRIPTION 120/208 VOLTS 3PHASE 4WIRE CKT NO. 1 SERVING: HOUSE LOADS 3.33 20 2 15 200 AMPS WITH MAIN LUGS CKT NO. LOAD DESCRIPTION KVA TRIP ET AMPS TRIP AMPS KVA LOAD DESCRIPTION CKT NO. 1 L-2 DRYER 5.00 30 20 1.50 L-2 WASHER 2 3 .83 7 2 20 3.12 AH -12 CU -12 4 5 CRAFT ROOM RECEPT. .36 20 2 GARAGE LIGHTS 6 6 7 CRAFT ROOM RECEPT. .54 1 SPACE 20 .54 CRAFT ROOM RECEPT. 8 9 COURTYARD FIRE PIT .18 CONNECTED LOAD: 4.6 KVA DEMAND LOAD: 5.4 KVA 20 1.08 COURTYARD LIGHTING 10 11 COURTYARD LIGHTING 1.53 20 20 .50 COURTYARD WATER FEAT. 12 13 L-3 DRYER 5.00 30 30A 5.00 L-3 DRYER 14 15 1.50 2 721 MEETING RM. RECEPTS. 16 16 17 L-3 DRYER 2.50 20 20 1.50 L-3 WASHER 18 19 L-3 WASHER 1.50 rz 30 5.00 L-4 DRYER 20 21 L-3 WASHER 1.502 1.50 MEDIA RM. DED. RECEPTS. 22 22 23 L-4 WASHER 1.50 30 5.00 L-4 DRYER 24 25 L-4 WASHER 1.50 20 2 L-2 LTS/RECEPTS. 26 26 27 L-4 DRYER 5.0030 50 20 1.50 L-4 WASHER 28 29 1.50 2 20 1.50 L-5 WASHER 30 31 L-5 DRYER 5.00 30 30 5.00 L-5 DRYER 32 33 3.54 30 2 2 AH -11 CU -11 34 34 35 SPACE 2 2 20 1.50 L-5 WASHER 36 37 1.08 20 20 1.32 L-3 LTS/RECEPTS. SPACE 38 39 1.42 20 20 1.29 L-3 LTS/RECEPTS. SPACE 40 41 1 SPACE I I SPACE 1 42 REMARKS: CONNECTED LOAD: 58.5 KVA 163 AMPS CONNECTED LOAD: 61.2 KVA 170 AMPS DEMAND LOAD: DEMAND LOAD: 64.7 KVA 180 AMPS PROVIDE HANDLE TIES FOR ALL MULTI -CIRCUIT HOMERUNS SHARING A NEUTRAL PER THE NATIONAL ELECTRIC CODE ARTICLE 210.4 MULTIWIRE BRANCH CIRCUITS, PART (B) DISCONNECTING MEANS. DRAWINGS ARE DIAGRAMMATIC. WHERE THE CONTRACTOR MODIFIES THE CIRCUITING, THE CONTRACTOR SHALL PROVIDE AN INDIVIDUAL NEUTRAL PER CIRCUIT, MULTI -POLE CIRCUIT BREAKERS, OR CIRCUIT BREAKER HANDLE TIE TO MEET THE NEC ARTICLE. ALL COSTS ASSOCIATED WITH MODIFICATIONS SHALL BE INCLUDED IN THE CONTRACTOR'S BID. SURFACE MOUNTING PANEL SCHEDULE 22,000 AIC EL2 LOCATION: SERVING: ELEV. MACH. RM. ELEV. MACH. RM. 1201208 VOLTS 1PH 3WIRE 60 AMPS WITH MAIN LUGS CKT NO. NO. E1 LOCATION: ELECTRICAL RM. TRIP AMPS KVA LOAD DESCRIPTION 120/208 VOLTS 3PHASE 4WIRE CKT NO. 1 SERVING: STANDBY LOADS 3.33 20 2 15 200 AMPS WITH MAIN LUGS CKT NO. LOAD DESCRIPTION KVA TRIP AMPS TRIP AMPS KVA LOAD DESCRIPTION CKT NO. 1 L-1 RECEPTACLES .85 20 20 1.21 L-1 RECEPTACLES 2 3 L-1 RECEPTACLES .83 7 SPACE 1.62 L-1 RECEPTACLES 4 5 L-1 RECEPTACLES .54 9 SPACE 1.54 GARAGE LIGHTS 6 7 GARAGE LIGHTS 1.34 11 1 SPACE 1.58 GARAGE LIGHTS 8 9 O/S LIGHTS .35 CONNECTED LOAD: 4.6 KVA DEMAND LOAD: 5.4 KVA .35 O/S LIGHTS 10 11 LOBBY,LOUNGE RECEPTS. .72 .54 LOBBY RECEPTS. 12 13 OFFICE RECEPTS. .90 1.50 MEETING RM. RECEPTS. 14 15 MEETING RM. RECEPTS. 1.50 .54 MEETING RM. RECEPTS. 16 17 MEZZ LOBBY LIGHTING .39 20 .90 MEZZ LOBBY RECEPTS. 18 19 AH -9 CU -9 3.12 20 .99 MEDIA RM. LTS/RECEPTS. 20 21 2 1.50 MEDIA RM. DED. RECEPTS. 22 23 MEZZ, GARAGE LIGHTS 1.47 20 1.40 L-2 LTS/RECEPTS. 24 25 L-2 LTS/RECEPTS. 1.62 20 1.57 L-2 LTS/RECEPTS. 26 27 COMM./GUEST RM. LTS .90 50 8.00 COMM. RM. RANGE 28 29 COMM. RM. DISHWASHERS 1.50 2 30 31 COMM. RM. APPLIANCE 1.50 20 20 1.50 COMM. RM. APP. CIRCUIT 32 33 AH -10 CU -10 3.54 30 30 3.54 AH -11 CU -11 34 35 2 2 36- 37 COMM. RM. RECEPTS. 1.08 20 20 1.32 L-3 LTS/RECEPTS. 38 39 L-3 LTS/RECEPTS. 1.42 20 20 1.29 L-3 LTS/RECEPTS. 40 41 ISPACE SPACE 42 REMARKS: . CONNECTED LOAD: 58.5 KVA 163 AMPS DEMAND LOAD: 61.4 KVA 171 AMPS PROVIDE HANDLE TIES FOR ALL MULTI -CIRCUIT HOMERUNS SHARING A NEUTRAL PER THE NATIONAL ELECTRIC CODE ARTICLE 210.4 MULTIWIRE BRANCH CIRCUITS, PART (B) DISCONNECTING MEANS. DRAWINGS ARE DIAGRAMMATIC. WHERE THE CONTRACTOR MODIFIES THE CIRCUITING, THE CONTRACTOR SHALL PROVIDE AN INDIVIDUAL NEUTRAL PER CIRCUIT, MULTI -POLE CIRCUIT BREAKERS, OR CIRCUIT BREAKER HANDLE TIE TO MEET THE NEC ARTICLE. ALL COSTS ASSOCIATED WITH MODIFICATIONS SHALL BE INCLUDED IN THE CONTRACTOR'S BID. SURFACE MOUNTING 10,000 AIC PANEL SCHEDULE NO. EL2 LOCATION: SERVING: ELEV. MACH. RM. ELEV. MACH. RM. 1201208 VOLTS 1PH 3WIRE 60 AMPS WITH MAIN LUGS CKT NO. LOAD DESCRIPTION KVA TRIP AMPS TRIP AMPS KVA LOAD DESCRIPTION CKT NO. 1 AC-E/CU-E 3.33 20 2 15 20 20 .31 PIT GFI LIGHT 2 3 .31 MACH. ROOM GFI LIGHT 4 5 MACHINE RM. CONTROLLER .60 SPACE 6 7 SPACE 8 9 SPACE 10 11 1 SPACE SPACE 12 REMARKS: CONNECTED LOAD: 4.6 KVA DEMAND LOAD: 5.4 KVA 22 AMPS 26 PROVIDE HANDLE TIES FOR ALL MULTI -CIRCUIT HOMERUNS SHARING A NEUTRAL PER THE NATIONAL ELECTRIC CODE ARTICL MULTIWIRE BRANCH CIRCUITS, PART (B) DISCONNECTING MEANS. DRAWINGS ARE DIAGRAMMATIC. WHERE THE CONTRACT( MODIFIES THE CIRCUITING, THE CONTRACTOR SHALL PROVIDE AN INDIVIDUAL NEUTRAL PER CIRCUIT, MULTI -POLE CIRCUITS OR CIRCUIT BREAKER HANDLE TIE TO MEET THE NEC ARTICLE. ALL COSTS ASSOCIATED WITH MODIFICATIONS SHALL BE INCI THE CONTRACTOR'S BID. IN JAN 19 2017 City of TuWila IFII 141,E1v �= w Q O D MCI It / Q0 0 N n 0 z a� iT E n Lo u Q0 0 N d - U 0 0 ,on SURFACE MOUNTING PANEL SCHEDULE 22,000 AIC 10,000 AIC NO. cl LOCATION: FUTURE TENANT 1 120/208 VOLTS 3PHASE 4WIRE UP SERVING: FUTURE TENANT 1 150 AMPS WITH MAIN LUGS CKT LOAD DESCRIPTION KVA TRIP NO. AMPS11 I TRIP KVA AMPS LOAD DESCRIPTION CKT NO. 1 RECEPT LIGHTS .45 20 a.30 5.41 AH -1 2 3 CU -1 3.49 30 2 4 5 2 1 SPACE 6 7 ISPACE 50 20 1.50 8 9 3 10 11 30 5.00 DRYER 12 13 HEAT 2.5015 14 15 6 16 17 2 18 19 8 9 1 20 21 20 20 1.50 22 23 11 GLL - ARC FAULT 24 25 20 .18 BATH GFI 26 27 BED ARC FAULT 1.50 28 29 BED ARC FAULT 14 30 31 I 32 33 16 REMARKS:. 34 35 CONNECTED LOAD: 26.6 KVA 128 AMPS 36 37 38 39 83 AMPS 40 41 ISPACE I ISPACE 1 42 REMARKS: CONNECTED LOAD: 9.3 KVA 26 AMPS DEMAND LOAD: 10.7 KVA 30 AMPS PROVIDE HANDLE TIES FOR ALL MULTI -CIRCUIT HOMERUNS SHARING A NEUTRAL PER THE NATIONAL ELECTRIC CODE ARTICLE 210.4 MULTIWIRE BRANCH CIRCUITS, PART (B) DISCONNECTING MEANS. DRAWINGS ARE DIAGRAMMATIC. WHERE THE CONTRACTOR MODIFIES THE CIRCUITING, THE CONTRACTOR SHALL PROVIDE AN INDIVIDUAL NEUTRAL PER CIRCUIT, MULTI -POLE CIRCUIT BREAKERS, OR CIRCUIT BREAKER HANDLE TIE TO MEET THE NEC ARTICLE. ALL COSTS ASSOCIATED WITH MODIFICATIONS SHALL BE INCLUDED IN THE CONTRACTOR'S BID. POLICE RESOURCE CENTER, (FUTURE) SURFACE MOUNTING PANEL SCHEDULE 22,000 AIC 10,000 AIC NO. C4 LOCATION: FUTURE TENANT 1 120/208 VOLTS 3PHASE 4WIRE UP SERVING: FUTURE TENANT 1 150 AMPS WITH MAIN LUGS CKT LOAD DESCRIPTION KVA TRIP NO. AMPS TRIP KVA AMPS LOAD DESCRIPTION CKT NO. 1 RECEPT LIGHTS .45 20 50 8.32 AH -4 2 3 CU -4 4.16 30 2 4 5 2 1 SPACE 6 7 SPACE 50 20 1.50 8. 9 3 10 11 30 5.00 DRYER 12 13 HEAT 2.5015 14 15 6 16 17 2 18 19 8 9 1 20 21 20 20 1.50 22 23 11 GLL - ARC FAULT 24 25 20 .18 BATH GFI 26 27 BED ARC FAULT 1.50 28 29 BED ARC FAULT 14 30 31 I 32 33 16 REMARKS:. 34 35 CONNECTED LOAD: 26.6 KVA 128 AMPS 36 37 38 39 83 AMPS 40 41 SPACE ISPACE SPACE 42 REMARKS: CONNECTED LOAD: 12.9 KVA 36 AMPS DEMAND LOAD: 15.0 KVA 42 AMPS PROVIDE HANDLE TIES FOR ALL MULTI -CIRCUIT HOMERUNS SHARING A NEUTRAL PER THE NATIONAL ELECTRIC CODE ARTICLE 210.4 MULTIWIRE BRANCH CIRCUITS, PART (B) DISCONNECTING MEANS. DRAWINGS ARE DIAGRAMMATIC, WHERE THE CONTRACTOR MODIFIES THE CIRCUITING, THE CONTRACTOR SHALL PROVIDE AN INDIVIDUAL NEUTRAL PER CIRCUIT, MULTI -POLE CIRCUIT BREAKERS, OR CIRCUIT BREAKER HANDLE TIE TO MEET THE NEC ARTICLE. ALL COSTS ASSOCIATED WITH MODIFICATIONS SHALL BE INCLUDED IN THE CONTRACTOR'S BID. UNIT PANEL FOR 2 -BEDROOM UNIT FLUSH MOUNTING PANEL SCHEDULE 22,000 AIC 10,000 AIC NO. C2 LOCATION: FUTURE TENANT 1 NO. UP LOCATION: 2 -BEDROOM (986 SQ. FT.) 1 120/208 VOLTS 1PH 3WIRE CKT LOAD DESCRIPTION KVA TRIPTRIP NO. AMPS AMPS KVA SERVING: UNIT .45 20 30 5.41 100 AMPS WITH MAIN LUGS CKT NO. LOAD DESCRIPTION KVA TRIP AMPS TRIP KVA AMPS LOAD DESCRIPTION CKT NO. 1 RANGE 8.00 50 20 1.50 WASHER 2 3 10 2 30 5.00 DRYER 4 5 HEAT 2.5015 14 2 6 7 17 2 20 1.50 KITCHEN 8 9 1 GLL - ARC FAULT 1.50 20 20 1.50 KITCHEN 10 11 GLL - ARC FAULT 1.50 20 20 .18 BATH GFI 12 13 BED ARC FAULT 1.50 20 20 1.50 BED ARC FAULT 14 15 SPACE I I ISPACE 33 16 REMARKS:. 34 35 CONNECTED LOAD: 26.6 KVA 128 AMPS 36 37 DEMAND LOAD: 17.4 KVA 83 AMPS * PROVIDE ARC FAULT CIRCUIT BREAKER ** PROVIDE DUAL FUNCTION ARC FAULT/GFCI CIRCUIT BREAKER NOTE: DEMAND LOAD CALCULATION PER NEC 220.40 SURFACE MOUNTING PANEL SCHEDULE 22,000 AIC 10,000 AIC NO. C2 LOCATION: FUTURE TENANT 1 120/208 VOLTS 3PHASE 4WIRE UP SERVING: FUTURE TENANT 1 150 AMPS WITH MAIN LUGS CKT LOAD DESCRIPTION KVA TRIPTRIP NO. AMPS AMPS KVA LOAD DESCRIPTION CKT NO. 1 RECEPT LIGHTS .45 20 30 5.41 AH -2 2 3 CU -2 3.49 30 2 4 5 2 1 SPACE 6 7 SPACE 50 20 1.50 8 9 3 10 11 30 5.00 DRYER 12 13 HEAT 1.75 14 15 6 16 17 2 18 19 8 9 20 21 20 20 1.50 22 23 11 GLL - ARC FAULT 24 25 20 .18 BATH GFI 26 27 BED ARC FAULT 1.50 28 29 SPACE 14 30 31 I 32 33 1 16 REMARKS:. 34 35 CONNECTED LOAD: 23.7 KVA 114 AMPS 36 37 38 39 76 AMPS 40 41 ISPACE ISPACE 42 REMARKS: . CONNECTED LOAD: 9.3 KVA 26 AMPS DEMAND LOAD: 10.7 KVA 30 AMPS PROVIDE HANDLE TIES FOR ALL MULTI -CIRCUIT HOMERUNS SHARING A NEUTRAL PER THE NATIONAL ELECTRIC CODE ARTICLE 210.4 MULTIWIRE BRANCH CIRCUITS, PART (B) DISCONNECTING MEANS. DRAWINGS ARE DIAGRAMMATIC. WHERE THE CONTRACTOR MODIFIES THE CIRCUITING, THE CONTRACTOR SHALL PROVIDE AN INDIVIDUAL NEUTRAL PER CIRCUIT, MULTI -POLE CIRCUIT BREAKERS, OR CIRCUIT BREAKER HANDLE TIE TO MEET THE NEC ARTICLE. ALL COSTS ASSOCIATED WITH MODIFICATIONS SHALL BE INCLUDED IN THE CONTRACTOR'S BID. JAN��J:��I������ FLUSH MOUNTING PANEL SCHEDULE 22,000 AIC 10,000 AIC NO. C3 LOCATION: FUTURE TENANT 1 NO. UP LOCATION: 1 -BEDROOM (678 SQ. FT.) 1 120/208 VOLTS 1PH 3WIRE CKT LOAD DESCRIPTION KVA TRIP Tr NO. AMPS SERVING: UNIT SERVING: UNIT .45 20 100 AMPS WITH MAIN LUGS 100 AMPS WITH MAIN LUGS CKT NO. LOAD DESCRIPTION KVA TRIP AMPS TRIP KVA AMPS LOAD DESCRIPTION CKT NO. 1 RANGE 8.0050 50 20 1.50 WASHER 2 3 10 2 30 5.00 DRYER 4 5 HEAT 1.75 15 2 6 7 17 2 20 1.50 KITCHEN 8 9 GLL - ARC FAULT 1.50 20 20 1.50 KITCHEN 10 11 GLL - ARC FAULT 1.50 20 20 .18 BATH GFI 12 13 BED ARC FAULT 1.50 20 29 SPACE 14 15 1 SPACE I I SPACE 1 16 REMARKS:. 34 35 CONNECTED LOAD: 23.7 KVA 114 AMPS 36 DEMAND LOAD: 15.8 KVA 76 AMPS * PROVIDE ARC FAULT CIRCUIT BREAKER ** PROVIDE DUAL FUNCTION ARC FAULT/GFCI CIRCUIT BREAKER NOTE: DEMAND LOAD CALCULATION PER NEC 220.40 UNIT PANEL FOR 2 -BEDROOM UNIT WITH WASHER AND DRYER FLUSH MOUNTING PANEL SCHEDULE 22,000 AIC 10,000 AIC NO. C3 LOCATION: FUTURE TENANT 1 NO. UP LOCATION: 2 -BEDROOM (925 SQ. FT.) FUTURE TENANT 120/208 VOLTS 1PH 3WIRE 150 AMPS WITH MAIN LUGS CKT LOAD DESCRIPTION KVA TRIP Tr NO. AMPS SERVING: UNIT LOAD DESCRIPTION CKT NO. 1 1 RECEPT LIGHTS .45 20 100 AMPS WITH MAIN LUGS CKT NO. LOAD DESCRIPTION KVA TRIP AMPS TRIP KVA AMPS LOAD DESCRIPTION CKT N0. 1 RANGE 8.00 50 20 1.50 WASHER 2 3 10 2 30 5.00 DRYER 4 5 HEAT 2.75 15 2 6 7 17 2 20 1.50 KITCHEN 8 9 GLL - ARC FAULT 1.50 20 20 1.50 KITCHEN 10 11 GLL - ARC FAULT 1.50 20 20 .18 BATH GFI 12 13 BED ARC FAULT INTERRUPT. 1.50 20 29 SPACE 14 15 SPACE I I I SPACE 16 REMARKS: 34 35 CONNECTED LOAD: 24.9 KVA 120 AMPS 36 DEMAND LOAD: 15.8 KVA 76 AMPS * PROVIDE ARC FAULT CIRCUIT BREAKER ** PROVIDE DUAL FUNCTION ARC FAULT/GFCI CIRCUIT BREAKER NOTE: DEMAND LOAD CALCULATION PER NEC 220.40 SURFACE MOUNTING PANEL SCHEDULE 22,000 AIC 10,000 AIC NO. C3 LOCATION: FUTURE TENANT 1 120/208 VOLTS 3PHASE 4WIRE UP SERVING: FUTURE TENANT 120/208 VOLTS 1PH 3WIRE 150 AMPS WITH MAIN LUGS CKT LOAD DESCRIPTION KVA TRIP Tr NO. AMPS TRIP KVA AMPS LOAD DESCRIPTION CKT NO. 1 1 RECEPT LIGHTS .45 20 60 11.19 AH -3 2 3 CU -3 4.16 30 2 4 5 2 1 SPACE 6 7 SPACE 50 20 1.50 8 9 3 10 11 30 5.00 DRYER 12 13 HEAT 1.50 14 15 1 6 16 17 2 18 19 8 9 20 21 20 20 1.50 22 23 11 GLL - ARC FAULT 24 25 20 .18 BATH GFI 26 27 BED ARC FAULT INTERRUPT. 1.50 28 29 SPACE 14 30 31 32 33 16 REMARKS: . 34 35 CONNECTED LOAD: 23.7 KVA 114 AMPS 36 38 39 72 AMPS 40 r37 41 SPACE SPACE 42 REMARKS: CONNECTED LOAD: 15.8 KVA 44 AMPS DEMAND LOAD: 18.6 KVA 52 AMPS PROVIDE HANDLE TIES FOR ALL MULTI -CIRCUIT HOMERUNS SHARING A NEUTRAL PER THE NATIONAL ELECTRIC CODE ARTICLE 210.4 MULTIWIRE BRANCH CIRCUITS, PART (B) DISCONNECTING MEANS. DRAWINGS ARE DIAGRAMMATIC. WHERE THE CONTRACTOR MODIFIES THE CIRCUITING, THE CONTRACTOR SHALL PROVIDE AN INDIVIDUAL NEUTRAL PER CIRCUIT, MULTI -POLE CIRCUIT BREAKERS, OR CIRCUIT BREAKER HANDLE TIE TO MEET THE NEC ARTICLE. ALL COSTS ASSOCIATED WITH MODIFICATIONS SHALL BE INCLUDED IN THE CONTRACTOR'S BID. UNIT PANEL FOR 1 -BEDROOM UNIT WITH WASHER AND DRYER FLUSH MOUNTING PANEL SCHEDULE 10,000 AIC NO. UP LOCATION: 1 -BEDROOM (563 SQ. FT.) 1 120/208 VOLTS 1PH 3WIRE SERVING: UNIT 100 AMPS WITH MAIN LUGS CKT N0, LOAD DESCRIPTION KVA TRIP AMPS TRIP KVA AMPS LOAD DESCRIPTION CKT NO, 1 RANGE 8.00 50 20 1.50 WASHER 2 3 2 30 5.00 DRYER 4 5 HEAT 1.50 15 2 6 7 2 20 1.50 KITCHEN 8 9 GLL - ARC FAULT 1.50 20 20 1.50 KITCHEN 10 11 GLL - ARC FAULT 1.50 20 20 .18 BATH GFI 12 13 BED ARC FAULT INTERRUPT. 1.50 20 SPACE 14 15 ISPACE ISPACE 16 REMARKS: . CONNECTED LOAD: 23.7 KVA 114 AMPS DEMAND LOAD: 14.9 KVA 72 AMPS PROVIDE ARC FAULT CIRCUIT BREAKER ** PROVIDE DUAL FUNCTION ARC FAULT/GFCI CIRCUIT BREAKER NOTE: DEMAND LOAD CALCULATION PER NEC 220.40 TOTAL BUILDING LOAD CALCULATION HOUSE SERVICE COMMERCIAL SPACES WITH FUTURE LOAD (43.2KVA x 4) x 25% LARGEST MOTOR TOTAL BUILDING SERVICE = 557.12 KVA EW.K• •l:��11 =172.80 KVA + 4.16 KVA =1006.77 KVA (2797 AMPS) @208V, 3PH JAN 19 2017 'City of TuWil , BUILDING DIVISION__ RECFEIVED CITY OF T UMMA DEL 19 2016 REVIEW SUB�IIITTAL Estimated Available Fault Currant Estimated Available Fault Curren MAIN MAIN SCG to NDP blDP to R 1 SecondaryVoltage � Secondary Voltage I � r L_J Total System Motor Load (HP) 151 Total System Motor Load (HP) Primary Available Fault Currant (A)Primary Available Fault Current (A) 0001 Primary Voltage .240001 Primary Voltage Transformer Rating (kVA) Transformer Rating (kVA) 7601 Nameplate Transformer impedance (%Z) Nameplate Transformer Impedance (%Z) 31 Rated Secondary current (A) Rated Secondary Current (A) 2082 or or Secondary Available Fault Currant (A) 1:240001 Secondary Vault, Vu9suls t•r.y I LUJOY Conductor Length (lir) Conductor Length (fL) Size of Conductors l0__L� I Size of Conductors v Copper00 Copper F Aluminum J Aluminum a In Conduit 0 In conduit Cable O Gable Steel oo Steel Non -Magnetic L..�r J Non -Magnetic C� Number of Sets 1 3 1 Number of Sets 9 r Fault Current Available (A) 20,294 Fault Current Available (A) 18,328 Estimated Available Fault Current Estimated Available Fault Current - MAIN MAIN R1 to nearest unit panel R-3 to nearest Unit panel v _ Secondary Voltage Zoe v Secondary Voltage Total System Motor Load (HP) 151 Total System Motor Load (HP) Primary Available Fault Current (A) 240,00 Primary Available Fault Current (A) 1 240001 _ Primary Voltage Primary Voltage Transformer Rating (kVA) Transformer Rating (kVA) Nameplate Transformer impedance (%Z) 1 3 Nameplate Transformer Impedance (%z) 3 Rated Secondary Current (A) 8 of ted Secondary Current (A) 2082 or Secondary Available Fault Current (A) Secondary Available Fault Current (A) Conductor Length (ft) 77 Conductor Length (ft) QSize of Conductors 1..._P. v Size of Conductors � Copper 0O� Caper Aluminum L �.`J Aluminum In Conduit 1J In Conduit Cable 0 Cable Steel O steel M Q Non -Magnetic Non�4Ulagnatic 4 Number of Sets L. I .J Number of Sets Fault Curr+entAvailable (A) 8,531 Fault Current Available (A) 8,582 r_� Estimated Available Fault Current - Estimated Available Fault Current _ OMAIN 0 MAiN iNfDP to Commercial AfDP w MDP to HP N Secondary Voltage 2D8 v Secondary Nottage I zas v �----� I,- Total Total System Motor Load (HP) ,( o Total System Motor Load (HP) �....�::J primary Available Fault Current (A) Primary Available Fault Current (A) Primary Nottage 40-001 Primary Voltage1251 j Transformer Rating (kVA) 735 W Transformer Rating (kVA) 501 Nameplate Transformer impedance ('%Z) tJ Nameplate Transformer impedance (%Z) Rated Secondary Current (A) 2082 Rated Secondary Current (A) 20 or or Secondary Available Fault Current (A) - Secondary Available Fault Current (A) Conductor Length (it) C= Conductor Length (ft) M Size of Conductors EKE / 5tze of Conductors v CopperO Copper Aluminum Aluminum m � D / Q In Conduit tta C Conduit ab{e O N Cable O f` O Non -Ma netic Non -Magnetic j Number of Sets Number of Sets �..2QOJ Fault Current Available (A) 17 759 Estill Current Available (A) 18,328 _ _ _ _ _ -.._ ___ : _ . __ __ ._ ' o — - _ N �_ ._ __._ �_ ._ ____ _ -- _-__ _. Estimated Available Faulf Current Estimated Available Fault Current _ _. MAIN MAIN MP to Transfer Switch Transfer Switch to Elft (� Secondary Voltage 2D8 v / secondary voltage ?�_._. L"J z TTotal System Motor Load (HP) Total System Motor Load (HP) 24 Prime- Available Fault Current (A) Primary Available Fault Current (A) Primary Voltage Primary Voltage 1 125UU1 Transformer Rating (kVA)` LT Transformer Rating (kVA) 7M� Nameplate Transformer Impedance (%Z) Nameplate Transformer impedance (%Z) Rated Secondary Current (A) 2 6 Rated Secondary Current (A) 2082 or or Secondary Available Fault Current (A) P Secondary Available Fault Current (A) Q r� Conductor Length (ft) 00 Conductor Length (ft)LO Size of Conductors v Size of Conductors O Copper Copper Aluminum � Aluminum � QO In Conduit ® In Conduit Cable O o cable. o N Steal p Steel O Non gnetic Nonmagnetic U Number of Sots 2 Number of Sets n Fault Current Available (A) 8,565 Fault Current Available (A) 0 O'l Estimated Available Fault Current MAIN - - MDP to R-.' Secondary Voltage tae v Total System Motor Load (HP) 15 Primary Available Fault Current (A) ZEM Primary Voltage m�ouv 1 i — Transformer Rating (kVA) 750 Nameplate Transformer Impedance (%Z) l.�.�31 Rated Secondary Current (A) 2082 or secondary Available Faun current (A) 1 203821 Conductor Length (ft) 55 Size of Conductors L� Copper F� Aluminum � In Conduit Cable O &feel Q Nan-ISagnallc 701. Number of Sets L.J Fault Current Available (A) 17,617 Estimated Available Fault Current MAIN - - Ft -4 to nearest unit panel Secondary Voltage tae v Total System Motor Load (HP) 15 Primary Available Fault Current (A) OW Primary Voltage m�ouv 1 i — Transformer stating (kVA) 750 Nameplate Transformer Impedance (%Z) l.�.�31 Rated Secondary Current (A) 2 82 or Secondary Available Fault Current (A) 1•�.�="` 7 Conductor Length (ft) e('"'—""" S Size of Conductors rr [W Copper F� Aluminum � In Conduit Cable O Steel Q Non -Magnetic 701. Number of Sets C3�.� J Fault Current Available (A)_ 9,986 Estimated Available Fault Current' IN - - Commercial MDP to C-9 Secondary Voltage 208 v Total System Motor Load (HP) r 15 Primary Available Fault Current (A) OW PrimaryVoltage m�ouv 1 i — Transformer Rating (kVA) 760 Nameplate Transformer impedance (%Z) l.�.�31 Rated Secondary Current (A) 20 2 or Secondary Available Fault Current (A) 77 9 Conductor Length (ft) 74 Stze of Conductors C_oo�:.CI m F� AluminumCopper n � In Conduit Cable O Steel Q Non -Magnetic d5 Number of Sets C3�.� J Fault Curren tAvailable (A) 9,986 Estimated Available Fauflt-urrent - MAIN EN to E-1 Secondary Voltage las Total System motor toad (HP) Primary Available Fault Current (A) I Primary Voltage lzauul Transformer Rating (kVA) 501 Nameplate Transformer Impedance (°%Z) Rated Secondary Current (A) 8 or Secondary Available Fault Current (A) Conductor Length (ft.) Size of Conductors _ Copper Aluminum In conduit Cable � steel O Non -Magnetic Number of Sets Fault Current Available (A) 71705 Estimated Available Fault Current WAIN - - MDP to R-,3 Secondary voltage v Total System Motor Load (HP) r 15 Primary Available Fault Current (A) OW Primary Voltage m�ouv 1 i — Transformer Rating (kVA) 730 Nameplate Transformer Impedance (%Z) l.�.�31 Rated Secondary Current (A) 2080 or Secondary Available Fault Currant (A) 77 9 Conductor Length (fL) 74 Size of Conductors--� 3/o v Copper O Aluminum q In Conduit Cable O Steel Q Non -Magnetic 0 Number of Sets C3�.� J Fault Current Available (A) 17,392 Estimated Available Fault Current MAIN - - HP to HP -3 Secondary Voltage 2� v Total System Motor Load (HP) r 15 Primary Available Fault Current (A) 24 Primary Voltage m�ouv 1 i — Transformer Rating (kVA) 750 Nameplate Transfo tear impedance (%Z) l.�.�31 Rated Secondary Current (A) 2082 or Secondary Available Fault Current (A) 77 9 Conductor Length (ft) 74 Size of Conductors 3/o v Copper Aluminum � In Conduit®—� Cable O Steel Q Non -Magnetic 0 Number of Sets l.w....i Fault Current Available (A) 9,889 Estimated Available Fault Current MAiN - - - CO/n/nerclal MDP to C-2 Secondary Voltage F27K� Total System Motor Load (HP) r 15 Primary Available Fault Current (A) Primary Voltage m�ouv 1 i — Transformer Rating (kVA) 750 Nameplate Transformer impedance (%Z) Rated Secondary Current (A) 2 or Secondary Available Fault Currant (A) 77 9 Conductor Length (ft) F _....�:! Size of Conductors 3/o v er Alum Aluminn um � In Conduct Cable O Steel O Non -Magnetic 0 Number of Sets.-_�.ri Fault Current Available (A) 8,192 Estimated Available Fault +urrenT-- .- MAIN - - EN to C-2 Secondary Voltage -� Total System Motor Load (HP) Primary Available Fault Current (A) Priiiwiy voltage m�ouv 1 i — Transformer Rating (kVA) 750 Nameplate Transformer Impedance (%Z) Rated Secondary Current (A) 2Q8 or Secondary Available Fault Current (A) Conductor Length (ft) Size of Conductors [25a :E Copper Alurrtlnum In Conduit Cable o Steel O Non gne0c dl Number of Sets Fault Current Available (A) 5,242 Estimated Available Fault Current Estimated Available Fault Current MAIN MAiN WDP to R-4 R-1 to nearest unit panel Secondary Voltage zas r Secondary Voltage Total System Motor Load (HP) r Total System Motor Load (HP) 177 Primary Available Fault Current (A) 24WO Primary Available Fault Current (A) Primary Voltage Primary Voltage Transformer Rating (kVA) Sol Transformer Rating (kVA) Nameplate Transformer Impedance t%A S NamePtate Transformer Impedance (%Z) Rated Secondary Current (A) B Rated Secondary Current (A) 2 or or Secondary Available Fault Current (A) Secondary Available Fault Current (A) Conductor Length QL) Conductor Length (ft) Size of Conductors"► � r --�i Slee of Conductors I' • .Copper ! � I Copper � p� Aluminum i e I Aluminum In Conduit �in Conduit Cable O Cable 0 Steal 0 Steel O Non -Magnetic 0 Non-Idagnetic Number of Sets Number of Sets R,.....:._J Fault Current Available (A) 16,547 Fault Current Available (A) 8,740 Estimated Available Fault Current _Estimated Available Fault Current ` 1 MAIN - MAIN HP to HP -2 HP to HP-? Secondary voltage I zas Secondary Voltage Total System Motor Load (HP) ...... . Total System Motor Load (HP) Primary Available Fault Current (A) 240 Primary Available Fault Current (A) Primary voltage Primary voltage Transformer Elating (kVA) 790 Transformer Rating (kVA) Nameplate Transformer impedance (%Z) Nameplate Transformer Impedance (°%2) Rated Secondary Current (A) 20 2. or Rated Secondary Current (A) or Secondary Available Fault Current (A) Secondary Available Fault Current (A) Conductor Length (ft) Conductor Length (ft.) Size of Conductors a' Site of Conductors • Copper � � Copper O Aluminum O Aluminum In Conduit 0 In Conduit Cable O Cable O Steel Steel O Non -Magnetic O Nan -Magnetic Number of Sets 1 Number of Sets Fault Current Available (A)_.._ 11,98 CwrMntAvailable (A) 140996 Estimated Available Fault Current' MAIN _Estimated Available Fault Current =' Commercial MDP to C-3 MAIN Commercial MDP to C-4 Secondary Voltage Secondary voltage =208'[w-] Total System Motor Load (HP) Total System Moor Load (HP) Primary Available Fault Currant (A) 24 Primary Voltage Primary Available Fault Current (A) I MR Primary Voltage 'transformer Rating (kVA) Transformer Rating (kVA) ' Nameplate Transformer Impedance ( Rated Secondary Current (A) 2082 Nameplate Transformer impedance (%Z) 1 — 31 or mated Secondary Current (A) 2082 Secondary Available Fault Current (A) or Secondary Available Fault Current (A) Conductor Length (ft.) Conductor Length (ft) Stm of Conductors Size of Conductors 3/6 v Copper f -` O Aluminum capper Aluminum 0 in Conduit Cable O in Conduit 0 Cable O Steel Steel O Non retic ® Non4Mgnetic LTJ Number of Sets Number of Sets Fault Current Available (A) 053 Fault Current Available (A) 6,046 Estimated Avails a su1��- -� Estma#ed Available Fault Current MAIN MAIN EM to Elevator -1 OW to 5levator; Secondary Voltage 2ae• SecondaryNottage- Total System Motor Load (HP) ® Total System Motor Load (HP)"tel Primary Available Fault Current (A) Po Primary Available Fault Current (A) Primary Voltage ---- PrimaryVoltage Transformer Rating (kVA) Transformer Rating (kVA) 7501 Nameplate Transformer Impedance (%Z) Nameplate Transformer Impedance (%Z) Rated Secondary Current (A) 2082 Rated Secondary Current (A) r- 2082 or or Secondary Available Fault Current (A)'Secondary Available Fault Current (A) 1.�._....� Conductor Length (ft.) '�1 Conductor Length (ft.) fir""1 Size of Conductors 2 v Size of Conductors Copper O hopper Aluminum Aluminum In Conduit to Conduit Cable' Cable O Steel O Steel Non -Magnetic tom._ J � Non -Magmatic Number of Sets �---� Number of Sets 1 Fault Current Available (A) 2,676 Fault Current Available (A) 5,473 City ®f �TUM11a BUILDING DIVISION Wtz. C FIV CITY OF 9 UIUv'Il.,A NEC 19 2015 PERMIT CENTER REVIEW SUBMITTAL / W 0) AI 0 N / cn n O D N iT 00 Ln I Q0 0 N d- U N a� O n k MAIN Tranfer Switch to Generator Secondary Voltage 208 :..___._ Total System Motor Load (HP) 7 Primary Available Fault Current (A) 24000 Primary Voltage 125001 Transformer Rating (kVA) 7501 Nameplate Transformer impedance (OAZ) 3 Rated Secondary Current (A) 20$2 or Secondary Available Fault Current (A) wwwrllwl Conductor Length (it) Size of Conductors 250 �► Copper 0 Aluminum In Conduit d Cable 0 Steel 0 Non -Magnetic Number of Sets Fault Current Available (A) OP544 CURRENT IN AMPERES X 10 AT 208 VOLTS Estimated Available Fault Current . _ _ . MAIN Ern to E1-7 Secondary Voltage zas _ Total System Motor Load (HP) Primary Available Fault Cu n*ent (A) 240001 Primary Voltage Transibmer Rating (kVA) 7501 Nameplate Transformer Impedance (%Z) 3 Rated Secondary Current (A) 2082 or Secondary Available Fault Current (A) 81931 Conductor Length (ti,) �1251 Size of Conductors Copper 0 Aluminum In Conduit b Cable Steel 0 Non -Magnetic Number of Sets Fault Current Available (A) 1,396 CURRENT IN AMPERES X 10 AT 208 VOLTS SIEMENS Easy= TM TIME -CURRENT CURVES Tukwila Village Blinding FAULT: Evergreen State Electric I Cross Engineers DATE: Dec D2, 2016 131r`: Panel EM - E11E2 Coordinaiton REVISION- 1 10000 00 1900 800 ?W lot 600 6M 500 50C 400 40C 300 30C 200 20( 40 AO 30 30 20 ZO 90 14C so as To 7C1 60 6q 50 50 40 AO 30 30 20 ZO 90 19 6 8 7 7 6 6 0 .04 Q 5 4 (`j O 4 W 3 W 3 to to z, x 2 W 2 W F- e :s .7 .7 .6 .6 .5 .6 .4, .4 .3 .3 2 .2 .03 .03 •02 .02 .01 two .01 t .S .d 1 a *�7111111111111111111111l 1111111111L 1 1, rk 1 : I1 " bl MAIN Em to EL -2 Secondary Voltage las 0 _8 _V_ Total System Motor Load (HP) ""-"" Primary Available Fault Current (A) 4 Primary Voltage 12500 Transformer Rating (kVA) 1 "....76� Nameplate Transformer Impedance (%Z) 3 Rated Secondary Current (A) 2082 or Secondary Available Fault Current (A) 81993 . +wrrrwrrr Conductor Length (fL) Size of Conductors Copper 0 Aluminum ® + In Conduit Cable Steel 0 Non -Magnetic @ Number of Sets 171 Fault Curmnt Available (A) , CURRENT IN AMPERES 10 AT 208 VOLTS 2 3 4 5 5 780 10 2 3 4 6 6 7 89 100 2 3 4 5 6 7 as 1{X10 2 3 4 567801115600 CURRENT 1N AMPERES X 10 AT 208 VOLTS, SIEMENS EaTCC TIME-CUREN7" CURVES Tukwila Milage Building FAULT: Evergreen State Electric / CM53 Engineers DATE: Dec 02, 2016 BY: Panel EM Ctodins'iton REMSION. 1 ----------- 801 701 60( 50( 40( 30( 20( F. i 7C 6C 5a Q 5 Z 4 O 3 w 2 i` .6 .7 _6 .5 .4 .3 .z .00 .07 .06 .05 .03 .02 .01 CURRENT IN AMPERES X 10 AT 208 VOLTS ,..SAO CURRENT IN AMPERES X 10 AT 208 VOLTS MEMENS EaSYTCC "nME-CURRENT CURVES. TukvAia Village Building FAULT:' Evergreen State Becbic / Crus Engineers DATE: Dw O:P, 2018 W Panel EM - ELVEL2 C*ordinaiton REVISION: I REVIEWED.FOR COMPLIANCE WITH FPA 70 - NEC JAN 19 2017 City oaf -Tukwila BUILDING DIV[ 1 N FC'INJ 0 CITY OF YUKIWILA DEC 19 2016 PERMIT CEiVTER REVIEW SUBMITTAL •i` REVISIONS: AS NOTED DATE: SHEET 12-14-16 DRAWN BY: JAE E504 CHECKED BY: SLH/GLW JOB NO.: OF 47 .08 OFi ,0S .05 .04 .04 .03 .03 •02 .02 .01 two .01 t .S .d 1 a *�7111111111111111111111l 1111111111L 1 1, rk 1 : I1 " bl MAIN Em to EL -2 Secondary Voltage las 0 _8 _V_ Total System Motor Load (HP) ""-"" Primary Available Fault Current (A) 4 Primary Voltage 12500 Transformer Rating (kVA) 1 "....76� Nameplate Transformer Impedance (%Z) 3 Rated Secondary Current (A) 2082 or Secondary Available Fault Current (A) 81993 . +wrrrwrrr Conductor Length (fL) Size of Conductors Copper 0 Aluminum ® + In Conduit Cable Steel 0 Non -Magnetic @ Number of Sets 171 Fault Curmnt Available (A) , CURRENT IN AMPERES 10 AT 208 VOLTS 2 3 4 5 5 780 10 2 3 4 6 6 7 89 100 2 3 4 5 6 7 as 1{X10 2 3 4 567801115600 CURRENT 1N AMPERES X 10 AT 208 VOLTS, SIEMENS EaTCC TIME-CUREN7" CURVES Tukwila Milage Building FAULT: Evergreen State Electric / CM53 Engineers DATE: Dec 02, 2016 BY: Panel EM Ctodins'iton REMSION. 1 ----------- 801 701 60( 50( 40( 30( 20( F. i 7C 6C 5a Q 5 Z 4 O 3 w 2 i` .6 .7 _6 .5 .4 .3 .z .00 .07 .06 .05 .03 .02 .01 CURRENT IN AMPERES X 10 AT 208 VOLTS ,..SAO CURRENT IN AMPERES X 10 AT 208 VOLTS MEMENS EaSYTCC "nME-CURRENT CURVES. TukvAia Village Building FAULT:' Evergreen State Becbic / Crus Engineers DATE: Dw O:P, 2018 W Panel EM - ELVEL2 C*ordinaiton REVISION: I REVIEWED.FOR COMPLIANCE WITH FPA 70 - NEC JAN 19 2017 City oaf -Tukwila BUILDING DIV[ 1 N FC'INJ 0 CITY OF YUKIWILA DEC 19 2016 PERMIT CEiVTER REVIEW SUBMITTAL •i` REVISIONS: AS NOTED DATE: SHEET 12-14-16 DRAWN BY: JAE E504 CHECKED BY: SLH/GLW JOB NO.: OF