HomeMy WebLinkAboutPermit PG16-0004 - FAMILY FUN CENTER - GAS PIPING TO ROOFTOP UNITSFAMILY FUN CENTER
7300 FUN CENTER WAY
EXPIRED
08/29/16
PG16-0004
City of Tukwila
• * Department of Community Development
• 6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206-431-3670
Inspection Request Line: 206-438-9350
Web site: http://www.TukwilaWA.gov
PLUMBING/GAS PIPING PERMIT
Parcel No: 2423049063
Address: 7300 FUN CENTER WAY
Project Name: FAMILY FUN CENTER
Owner:
2012
Name:
FAMILY FUN CENTERS TUKWILA
Address:
7300 FUN CENTER WAY, TUKWILA,
WA Cities Electrical Code:
WA, 98188
Contact Person:
2012
Name:
ALEX BURKHART
Address:
727 S KENYON ST, SEATTLE, WA,
WA State Energy Code:
98108
Contractor:
2012
Name:
EVERGREEN REFRIGERATION LLC
Address:
727 S KENYON ST, SEATTLE, WA,
98108
License No:
EVERGRL954R2
Lender:
Name:
Address:
DESCRIPTION OF WORK:
INSTALLATION OF GAS PIPING TO (4) ROOFTOP UNITS
Permit Number: PG16-0004
Issue Date: 2/23/2016
Permit Expires On: 8/21/2016
Phone: (206) 763-1744
Phone: (206) 763-1744
Expiration Date: 1/6/2018
Valuation of Work: $6,860.00 Fees Collected: $126.76
Water District: TUKWILA
Sewer District: TUKWILA SEWER SERVICE
Current Codes adopted by the City of Tukwila:
International Building Code Edition:
2012
National Electrical Code:
2014
International Residential Code Edition:
2012
WA Cities Electrical Code:
2014
International Mechanical Code Edition:
2012
WAC 296-46B:
2014
Uniform Plumbing Code Edition:
2012
WA State Energy Code:
2012
International Fuel Gas Code:
2012
Permit Center Authorized Signature: r� l� t Date: ��
I hearby certify that I have read and examined this permit and know the same to be true and correct. All
provisions of law and ordinances governing this work will be complied with, whether specified herein or not.
The granting of this permit does not presume to give authority to violate or cancel the provisions of any other
state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this
development pe
rmit and agree to the conditions attached to this permit.
Signature: Date: 'Z'Z3 /14
Print Name: 1�%'�✓—
This permit shall become null and void if the work is not commenced within 180 days for the date of issuance, or if
the work is suspended or abandoned for a period of 180 days from the last inspection.
PERMIT CONDITIONS:
1: ***PLUMBING/GAS PIPING PERMIT CONDITIONS***
2: No changes shall be made to applicable plans and specifications unless prior approval is obtained from the
Tukwila Building Division.
3: All permits, inspection records and applicable plans shall be maintained at the job and available to the
plumbing inspector.
4: All plumbing and gas piping systems shall be installed in compliance with the Uniform Plumbing Code and
the Fuel Gas Code.
S: No portion of any plumbing system or gas piping shall be concealed until inspected and approved.
6: All plumbing and gas piping systems shall be tested and approved as required by the Plumbing Code and
Fuel Gas Code. Tests shall be conducted in the presence of the Plumbing Inspector. It shall be the duty of
the holder of the permit to make sure that the work will stand the test prescribed before giving notification
that the work is ready for inspection.
7: No water, soil, or waste pipe shall be installed or permitted outside of a building or in an exterior wall
unless, adequate provision is made to protect such pipe from freezing. All hot and cold water pipes
installed outside the conditioned space shall be insulated to minimum R-3.
8: Plastic and copper piping running through framing members to within one (1) inch of the exposed framing
shall be protected by steel nail plates not less than 18 guage.
9: Piping through concrete or masonry walls shall not be subject to any load from building construction. No
plumbing piping shall be directly embedded in concrete or masonry.
10: All pipes penetrating floor/ceiling assemblies and fire -resistance rated walls or partitions shall be protected
in accordance with the requirements of the building code.
11: Piping in the ground shall be laid on a firm bed for its entire length. Trenches shall be backfilled in thin
layers to twelve inches above the top of the piping with clean earth, which shall not contain stones,
boulders, cinderfill, frozen earth, or construction debris.
12: The issuance of a permit or approval of plans and specifications shall not be construed to be a permit for, or
an approval of, any violation of any of the provisions of the Plumbing Code or Fuel Gas Code or any other
ordinance of the jurisdiction.
13: The applicant agrees that he or she will hire a licensed plumber to perform the work outlined in this permit.
14: All new plumbing fixtures installed in new construction and all remodeling involving replacement of
plumbing fixtures in all residential, hotel, motel, school, industrial, commercial use or other occupancies
that use significant quantities of water shall comply with Washington States Water Efficiency ad
Conservation Standards in accordance with RCW 19.27.170 and the 2006 Uniform Plumbing Code Section
402 of Washington State Amendments
PERMIT INSPECTIONS REQUIRED
Permit Inspection Line: (206) 438-9350
2000 GAS PIPING FINAL
9002 ROUGH -IN GAS PIPING
CITY OF TUKWI .
Community Development Department
Permit Center
• 6300 Southcenter Blvd., Suite 100
Tukwila, WA 98188
http://xN,ww.TukwilaWA.
Plumbing/Gas Permit No.
Project No.
Date Application Accepted:
Date Application Expires: `!
PLUMBING / GAS PIPING PERMIT APPLICATION
Applications and plans must be complete in order to be accepted for plan review.
Applications will not be accepted through the mail or by fax.
"Please Print"
SITE LOCATION
King Co Assessor's Tax No.: 2423049063
Site Address: 7300 Fun Center Way Suite Number: Floor:
Tenant Name: Family Fun Center New Tenant: ❑ .....Yes m ..No
PROPERTY OWNER
Name: Family Fun Centers
Address: 7300 Fun Center Way
City: Tukwila State: WA Zip: 98188
CONTACT PERSON — person receiving all project
communication
Name: Alex Burkhart
Address: 727 South Kenyon St.
City: Seattle State: WA Zip: 98108
Phone: (206) 763-1744 Fax: (206) 763-2389
Email: alexb@evergreenhvac.com
Valuation of Project (contractor's bid price): $ 6,860
Scope of Work (please provide detailed information):
Installation of gas piping to four (4) rooftop units.
Building Use (per Int'l Building Code):
Occupancy (per Int'l Building Code):
Utility Purveyor: Water:
H:\Applimtions\Forms-Applications On Linc\2011 Applications\Plumbing Permit Application Revised 8-9-1 Ldocx
Revised: August 2011
bb
PLUMBING CONTRACTOR INFORMATION
Company Name: Evergreen Refrigeration
Address: 727 South Kenyon St.
City: Seattle State: WA Zip: 98108
Phone: (206) 763-1744 Fax: (206) 763-2389
Contr Reg No.: EVERGRL954R2 Exp Date: 01/06/2016
Tukwila Business License No.: BUS -0992877
Sewer:
Page] of 2
Indicate type of plumbing fixtures and/ot- as piping outlets being installed and the quantity celow:
Fixture Type
Qty
Bathtub or combination
bath/shower
Dishwasher, domestic with
independent drain
Shower, single head trap
Sinks
Rain water system — per
drain (inside building)
Grease interceptor for
commercial kitchen (>750
gallon capacity)
Each additional medical
gas inlets/outlets greater
than 5
Atmospheric -type vacuum
breakers not included in
lawn sprinkler backflow
protections 1-5
Fixture Type
Qty
Bidet
Drinking fountain or water
cooler (per head
Lavatory
Urinal
Water heater and/or vent
Repair or alteration of
water piping and/or water
treatment equipment
Backflow protective device
other than atmospheric -
type vacuum breakers 2
inch (51 mm) diameter or
smaller
Atmospheric -type vacuum
breakers not included in
lawn sprinkler backflow
protections over 5
PERMIT APPLICATION NOTES -
Fixture Type
Qty
Clothes washer,
domestic
Food -waste grinder,
commercial
Wash fountain
Water closet
Industrial waste
treatment interceptor,
including trap and vent,
except for kitchen type
rease interceptors
Repair or alteration of
drainage or vent piping
Backflow protective
device other than
atmospheric -type
vacuum breakers over 2
inch 51 mm diameter
Gas piping outlets
4
Fixture Type
Qty
Dental unit, cuspidor
Floor drain
Receptor, indirect waste
Building sewer and each
trailer ark sewer
Each grease trap
(connected to not more
than 4 fixtures - <750
gallon capacity
Medical gas piping
system serving 1-5
inlets/outlets for a specific
as
Each lawn sprinkler
system on any one meter
including backflow
protection devices
Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject
to possible revision by the Permit Center to comply with current fee schedules.
Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation.
The Building Official may grant one extension of time for an additional period not to exceed 180 days. The extension shall be requested in writing
and justifiable cause demonstrated. Section 103.4.3 International Plumbing Code (current edition).
I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER
PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT.
BUILDING OWNER OR AUTHORIZED AGENT:
Signature:bl / (�. ( 1 S
^ Date:_
Print Name: Alex Burkhart Day Telephone: (206) 763-1744
Mailing Address: 727 South Kenyon St. Seattle, WA 98108
City State Zip
H:\Applications\Fours-Applications On Line\2011 ApplicationAi'lumbing Permit Application Revised 8-9-1 I.docs
Revised: August 2011 Page 2 of 2
bb
DESCRIPTIONS
PermitTRAK
•
QUANTITY
PAID
$1,254.61
EL16-0057 Address: 7300 FUN CENTER WAY
Apn: 2423049063
$90.83
ELECTRICAL
$86.50
PERMIT FEE MULTI-FAM/COMM
R000.322.101.00.00
0.00
$86.50
TECHNOLOGY FEE
$4.33
TECHNOLOGY FEE
R000.322.900.04.00
0.00
$4.33
M16-0011 Address: 7300 FUN CENTER WAY
Apn: 2423049063
$1,037.02
MECHANICAL
$997.13
PERMIT ISSUANCE BASE FEE
R000.322.100.00.00
0.00
$32.50
PERMIT FEE
R000.322.100.00.00
0.00
$765.20
PLAN CHECK FEE
R000.322.102.00.00
0.00
$199.43
TECHNOLOGY FEE
$39.89
TECHNOLOGY FEE
R000.322.900.04.00
0.00
$39.89
PG16-0004 Address: 7300 FUN CENTER WAY
Apn: 2423049063
$126.76
GAS
$121.88
PERMIT ISSUANCE BASE FEE
R000.322.100.00.00
0.00
$32.50
PERMIT FEE
R000.322.100.00.00
0.00
$65.00
PLAN CHECK FEE
R000.322.103.00.00
0.00
$24.38
TECHNOLOGY FEE
$4.88
TECHNOLOGY FEE
TOTAL FEES " 1
R000.322.900.04.00
0.00
$4.88
Date Paid: Tuesday, January 19, 2016
Paid By: EVERGREEN REFRIGERATION LLC
Pay Method: CHECK 007684
Printed: Tuesday, January 19, 2016 10:36 AM 1 of 1 r"A
' f SYSTEMS
INSPECTION RECORD
I Retain a copy with permit lrn �
lNSP C?( N0. PERMIT N0.
CITY OF TUK111i'ILA BUILDING DIVISION
6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670
Permit Inspection Request Line (206) 438-9350
Pr�c
Tyof Inspection:
�
Address:
-7-30p FoLk-
Date Cal d:
Special Instructions: Aw
Date Wanted: a.m.
_'2 — p.m.
Requester:
Phone No:
Inspector: Date.-
REINSPECTION
ate:
REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be
paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection.
6/30/2016
City of Tukwila Allan Ekberg, Mayor
Department of Community Development Jack Pace, Director
ALEX BURKHART
727 S KENYON ST
SEATTLE, WA 98108
RE: Permit No. PG 16-0004
FAMILY FUN CENTER
7300 FUN CENTER WAY
Dear Permit Holder:
In reviewing our current records, the above noted permit has not received a final inspection by the City of Tukwila Building
Division. Per the International Building Code, International Mechanical Code, Uniform Plumbing Code and/or the National Electric
Code, every permit issued by the Building Division under the provisions of these codes shall expire by limitation and become null
and void if the building or work authorized by such permit has not begun within 180 days from the issuance date of such permit, or if
the building or work authorized by such permit is suspended or abandoned at any time after the work has begun for a period of 180
days. Your permit will expire on 8/29/2016.
Based on the above, you are hereby advised to:
1) Call the City of Tukwila Inspection Request Line at 206-438-9350 to schedule for the next or final inspection. Each
inspection creates a new 180 day period, provided the inspection shows progress.
-or-
2) Submit a written request for permit extension to the Permit Center at least seven(7) days before it is due to expire.
Address your extension request to the Building Official and state your reason(s) for the need to extend your permit.
The Building Code does allow the Building Official to approve one extension of up to 180 days. If it is determined that your
extension request is granted, you will be notified by mail.
In the event you do not call for an inspection and/or receive an extension prior to 8/29/2016, your permit will become null and void
and any further work on the project will require a new permit and associated fees.
Thank you for your cooperation in this matter.
Sincerely,
Bill Rambo
Permit Technician
File No: PG16-0004
6300 Southcenter Boulevard Suite #100 • Tukwila, Washington 98188 * Phone 206-431-3670 • Fax 206-431-3665
'tHVAC &
'
Eye
�An CONTROLS
�`// �`•// DESIGN
Refrigeration &HVAC INSTALLATION
SERVICE
CORRECTION LETTER #1 RESPONSE
To: City of Tukwila Department of Community Development
Attn: Allen Johannessen
Permit #: PG 16-0004
1. Please verify with calculations the sizing of the gas piping shall meet the total
demand of the new units with other mechanical units possibly connected to the same
gas line.
Response: We are installing a new gas line from the existing meter to serve four new
units. It has been sized per 2012 IFGC table 402.4 with a developed length of 350' and a
total of 511 CFH. Gas sizing isometric and calculations have been added to a new plan
page M3.
If you have any questions or comments, please contact me at the information located below.
Sincerely,
Alex Burkhart
Evergreen Refrigeration, LLC
727 S. Kenyon St.
Seattle, WA 98108
Desk: 206-763-1744 ext. 247
Fax: 206-763-2389
alexb@evergreenhvac.com
CORRECTION
LTR#..J,-
PG lb,- 000 jq
727 SOUTH KENYON ST. - SEATTLE, WA. 98108
(206) 763-1744 - FAx (206) 763-2389
RECEIVED
CITY OF TUKWILA
FEB 16 2016
PERMIT CENTER
City of Tukwila
Allan Ekberg, Mayor
Department of Community Development Jack Pace, Director
January 29, 2016
ALEX BURKHART
727 S KENYON ST
SEATTLE, WA 98108
RE: Correction Letter # 1
PLUMBING/GAS PIPING Permit Application Number PG 16-0004
FAMILY FUN CENTER - 7300 FUN CENTER WAY
Dear ALEX BURKHART,
This letter is to inform you of corrections that must be addressed before your development permit can be approved. All
correction requests from each department must be addressed at the same time and reflected on your drawings. I have
enclosed comments from the following departments:
BUILDING - DEPARTMENT: Allen Johannessen at 206-433-7163 if you have questions regarding these comments.
• (GENERAL NOTE)
PLAN SUBMITTALS: (Min. size 11x17 to maximum size of 2406; all sheets shall be the same size. New revised
plan sheets shall be the same size sheets as those previously submitted.)
(If applicable) "STAMP AND SIGNATURES" "Every page of a plan set must contain the seal/stamp, signature of
the licensee(s) who prepared or who had direct supervision over the preparation of the work, and date of signature.
Specifications that are prepared by or under the direct supervision of a licensee shall contain the seal/stamp,
signature of the licensee and the date of signature. If the "specifications" prepared by a licensee are a portion of a
bound specification document that contains specifications other than that of an engineering or land surveying
nature, the licensee need only seal/stamp that portion or portions of the documents for which the licensee is
responsible." It shall not be required to have each page of "specifications" (calculations) to be stamped and signed;
Front page only will be sufficient. (WAC 196-23-010 & 196-23-020)
(BUILDING REVIEW NOTES)
1. Please verify with calculations the sizing of the gas piping shall meet the total demand of the new units with
other mechanical units possibly connected to the same gas line.
Please address the comments above in an itemized format with applicable revised plans, specifications, and/or other
documentation. The City requires that two 2 sets of revised plan pages, specifications and/or other documentation be
resubmitted with the appropriate revision block.
In order to better expedite your resubmittal, a 'Revision Submittal Sheet' must accompany every resubmittal. I have
enclosed one for your convenience. Corrections/revisions must be made in person and will not be accepted through the mail
or by a messenger service.
If you have any questions, I can be reached at (206)433-7165.
Sincerely, Vi
Fa1lle Rilety"
P
Permit Technician
File No. PG 16-0004
6300.Snuthcentpr Rnulpvnrd ,Sui.ta #Inn e Tulewiln Wnchinatrm 9R7RR • Phnno ?nA,_d3l_ 67n a Fnr ?06_4?1_244i
PERMIT COORD COPY
PLAN REVIEW/ROUTING SLIP
PERMIT NUMBER: PG16-0004 DATE: 02/16/16
PROJECT NAME: FAMILY FUN CENTER
SITE ADDRESS: 7300 FUN CENTER WAY
Original Plan Submittal Revision # before Permit Issued
X Response to Correction Letter # 1 Revision # after Permit Issued
DEPARTMENTS:
Building Division a Fire Prevention ❑ Planning Division ❑
Public Works ❑ Structural ❑ Permit Coordinator
PRELIMINARY REVIEW: DATE: 02/18/16
Not Applicable ❑ Structural Review Required ❑
(no approval/review required)
REVIEWER'S INITIALS: DATE:
APPROVALS OR CORRECTIONS: DUE DATE: 03/17/16
Approved ❑ Approved with Conditions LON
Corrections Required ❑ Denied ❑
(corrections entered in Reviews) (ie: Zoning Issues)
Notation:
REVIEWER'S INITIALS: DATE:
Permit Center Use Only
CORRECTION LETTER MAILED:
Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials:
12/18/2013
PERMIT COORD COPY
PLAN REVIEW/ROUTING SLIP
PERMIT NUMBER: PG16-0004 DATE: 01/20/16
PROJECT NAME: FAMILY FUN CENTER
SITE ADDRESS: 7300 FUN CENTER WAY
X Original Plan Submittal
Response to Correction Letter #,
Revision # before Permit Issued
Revision # after Permit Issued
DEPARTMENTS:
Goy ( k I �/�q
Building Division Fire Prevention ❑ Planning Division ❑
W
Ar/Y� d Structural ❑ Permit Coordinator
PRELIMINARY REVIEW: DATE: 01/21/16
Not Applicable ❑ Structural Review Required ❑
(no approval review required)
REVIEWER'S INITIALS:
APPROVALS OR CORRECTIONS:
DATE:
DUE DATE: 02/18/16
Approved ❑ Approved with Conditions ❑
Corrections Required ❑
(corrections entered in Reviews)
Notation:
REVIEWER'S INITIALS:
Denied ❑
(ie: Zoning Issues)
DATE:
Permit Center Use Only
CORRECTION LETTER MAILED:
Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials:
1znsizois
City of Tukwila
Department of Community Development
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206-431-3670
Web site: http://www.Tukwi]aWA
REVISION
SUBMITTAL
Revision submittals must be submitted in person at the Permit Center. Revisions will not be accepted through
the mail, fax, etc.
Date: (z_ ("6 /t'c Plan Check/Permit Number: '? U � L J 00 L+
Response to Incomplete Letter #
Response to Correction Letter # �—
Revision # after Permit is Issued
Revision requested by a City Building Inspector or Plans Examiner
Project Name: FamiL7�'
ProjectAddress: ._73cO ren
Contact Person: Phone Number: '1,6--763– t–I4H evA_'M 7
Summary of Revision:
�n,,l $ .
RECEIVED
CITY OF TUKWILA
FEB 16 2016
PERMIT CENTER
Sheet Number(s): /'A' I /t,2 I /-L �
"Cloud" or highlight all areas of revision including date of revision
C
Received at the City of Tukwila Permit Center by
12' Entered in Permits Plus on
H:\Applications\Forms-Applications On Line\2010 Applications\7-2010 -Revision Submitlal.doc
Revised: May 2011
EVERGREEN REFRIGERATION I.1C
4nWashington State Department of
Labor & Industries
Page 1 of 3
Horne Espanol Contact Search L&I
A -I Index Help My Secure L&I
Safety & Health Claims & Insurance Workplace Rights Trades & Licensing
EVERGREEN REFRIGERATION LLC
Owner or tradesperson 727 S KENYON ST
Principals SEATTLE, WA98108
p 206-763-1744
PATTON, RODGER, PARTNER/MEMBER KING County
PATTON, MATTHEW, PARTNER/MEMBER
Patton, Adam, PARTNER/MEMBER
Patton, Douglas, PARTNER/MEMBER
EVERGREEN REFRIGERATION
LLC, PARTNER/MEMBER
PATTON, DAVID, PARTNER/MEMBER
(End: 01/21/2014)
Doing business as
EVERGREEN REFRIGERATION LLC
WA UBI No. Business type
602 512 953 Limited Liability Company
Governing persons
DAVID
A
PATTON
MATTHEW PATTON;
RODGER PATTON;
License
Verify the contractor's active registration / license / certification (depending on trade) and any past violations.
Construction Contractor Active.
Meets current requirements.
License specialties
GENERAL
License no.
EVERGRL954R2
Effective — expiration
01/06/2006— 01/06/2018
Bond
.................
Merchants Bonding Co (Mutual)
$12,000.00
Bond account no.
WA15097
Received by L&I
Effective date
12/15/2011
01/01/2012
Expiration date
Until Canceled
Bond history
Insurance
..............................
Nationwide Mutual Ins Co $1,000,000.00
Policy no.
ACP 3007246151
https:Hsecure.Ini.wa.gov/verify/Detail.aspx?UBI=602512953&LIC=EVERGRL954R2&SAW= 2/23/2016
f n uP
J 4 A.I f rr
V k. € k � tl.;• C 4J f I r rA i
_ 1 F C 6 I nl u;l. F 8n
i rt
f P I 1 f i j
1 I I i
t
1 I x
N f
r I nx. ani I e I }
7 k it C V ; 44 I e U
A
I a U i
IMI G
Nm
P
.: Y,p {r,,
,,. ...
, .., -
i-.e._k_4..I
r i _j,�
r ., r„ Uu,x. ,-rt. N;J.,,r; •n_e,1: 1.. ,x,w v.'x,Jv. �. ,. ,,, r, r. ,.,, ,. 4 ..:
. l......I _. N.. {...
Ir.:,.a•r
.v.r.x.rL ,cry ':rx:,I. Mnx av:e4r1-.,.. .: r:ir, i... ,. ,. .. ,. ..., -i•
I , .r .. z.. x •. _, 1. u..u... J, ,-x.. f ,:. x. .
, r. ] , a t t •♦ ,,: JI Ir....x.r- ,.xr r.l. . it ..... .. ., -C.. .. .,...
} J..�tk...e SA...4.. ..,,if , ,ri[ ....t . n, r:. ,. t., . •.. ' v _ 1 , ♦...
t .,. xi...{,r„t 1„ A..urr,.x .. rr..�.^Jt ,r.. ... ,.: ,.. r -'r•- _. •..
I r w. I I ', e -n. r.v. .x r. ,,..x. K, ,:,,x-. : -L, x..,.- It.:n n• .xxr..,.x_ a ... .
. >..nt,4.
4 ..-hP:.4
xralwL.,u�:'..ffr>.x.Mw.„u,,ff«VP .,..,It €. GI e.,... nrn. .,.,,..r,..PJr,,.,.Irar._n. rI..,.aJl�., Ga ,:,¢I.,>r. ,ar ....,.. .r.. .:. -..1.>., !•.. • r ar , .l .r,lr,rr..:.,.,u.,..,N .,>", s.d.J,r�a.,
,�-,U ..u -k_ ..r...xu1;,.k.r... r.:. .., c..rl .. r: e. .a:a.4., u.r.,+,x.,. . .. v•. , rA. >x drr rJ} " `._: a.
.,.,
._
,.
.,,r>Ln<N.I,. f. Iv x J , t1 • � I ., , rw A,. ,.,._r ..,.,x.<..r ,xN ,. �,: �w..,�J<nrl,,N,
r .. ...,.. _..,'4 .P, ....G_i dh J l,.ds... l4 , ,.ra f�s .P. W >., .1,..J,. r C.. _.. ,,... ,....,. .. •. .. " _ _:: ,-,,:A >
,fv
•., - -k. xl �.: ,i t f ! r-:. ,. 5. a ,, r. n ,,,. .. rn. r. :, v e. ..,a.
, �... .,r x< . • ......x`I-,. it• 1: aN.lr ir.,l .. r...r Ir x .r .M1 r , x N : _, r. tl p. �., _ r.. .. _ .4 I r...
, -..N. .., .
C r
R^.t [.
a
a ... ,.,+ N l.r. P,. • r; ,.like �.,,lr.,.,. �. ..r n...x, vl,. n x_x. ,.,> f. ,,, ,G., .,,«:, ,N
k �
^.firs.. .A .f., i.. .. NI r.FN v... 1.- n n, ..ar.. .. ..•ti a f... :f
n i
-
}k,M
rf
a ,•a r Ir r d 1 c c- ,,. ,
u*` o-�
[ .vv. 1: .xN •.L: .I if I n.a,:,l 1. I N I ,.x . ,•rFr'. � .
I r
£,'..,
41 ST KPdQ J4 � ;• ] �'t
i
JHS i Y Pd
t
�_,. Lb.1.., .. „4 §P: _, ... , ,mod. . n. .. a. E `3•. @ 3. ": -.
r
d k
M
veavrrd.4+wi✓•r4+•�` r r N I�
i ll6 hrtit r aM:a, vr+ ,.: { r
., r.,r '>,. r ♦. .,ax n. r.. x._4a.x ... .x 'W
s4
4 6
k p ✓
t yy p.• a e ,il u.NI G 1r i "� „,
I
+ t
fi a
N
k JS A' fi Q S
, r
< f 2
[ � I
4 ,
+ 1
s n n
Q 4 P 1 4 V Cal '
I 4d C J
i 4 of
1 J I 4 I ax
� h
,
l
t 1 f JN t I 1
T
3
fr
: 1, 1 I I 4 1 I ; A F t •, .. 9 n x l Tn -
> JE t W t h 1
rl 14r i'i4 Nl_ i t :.� � I J,' t2 it ort Y ,n Ct 4 u n 4 V.. ¢t •. `s
_ , y
N.
n
r JJ I 4 7, h
E l i I k •v i> � r'.
�t n4ri I I 11 � 1 k r 1 k
N
r !f `I! J "•,c 4.' to k J 4 :d a ti'• 43 Y
u r
1 r + tF
p p :f Ir i 1i
it
IN z
" .I,. Nx F •' "ilY. A I .":: r: `' , 1 ,..,_ ., ,,..t_4,d€.?.. a. ,. , .F 'i, i. ,..y.y ,•'F'f k .
t
11
v. uvpx
I
� r
I I
s F U, ne
r k
rI (fir I I w a 1 : IN
dl u.
I � 1
d ,
J fl •'4n A t. a tl ' d§CF IIaC i• F s rJ4 4 9 1
v.... # .,
h
,. r.
,
r,l r 41 V 1 a F
,
1,l .a
:.
,
q J
r r r p r « I
^r
.rt..r.-
_..u,..,
I3
5 xI N
I P t{
.• f ht a
d, 11r Ire �[ t F td _ai h#
As } J rl
1
,
, r
C
4
x
rM1r F
fr,
VI C
NITY MAP
SCALE: NONE
-
.an
X•
l
/r\
1
rr
Q'
t
•l1 r
I /
f /
17:r•
1 •
b l
}i 6
t? .
a
r
•Y' r
+
0. 1
r
t
1
tt
•"J
/ r
/ � 1
1
,
t
l 1
1
U• /
,t _r
,i
t; -tint •:,t
}
J
/•r •• 1
_ t
t
G'• l
1
u
.,; tom• - L, � t
r. t
1
q
1
/tt
l
t
1,.
fir' ;� I ,�t ��;•l'r .� ,1'
•F�1 It
`` 1
1
1rJ
r �•
Ii
r
,
••-r
Y, FAL '•�, .•''• ° _ �''
r'y-t
sl 4 r 1
t-
1Sam.-.
f
,
.r
jJ
.,. -
{ GAS PIPING LENGTH.
s
/
1
r. • t
+, r
I 1 ..r't • t-. ' !t
7 v 1?t
1' 1
. F 4
1
1
i I
1
I
•� v 1
I
i t .y � • � M, � - '�' �'r , ,:' ILII
1- ••c r � �
r�
i
l4. 'Lt 5 1
• ,1
;' � ; LII
I _
,�: t';: � G : ',; ;, • ., 4._
,, V111
I
ll �t • .1 x.
t
t
S
I T' ••
=v �
t 1�
a _
1 f '' 1' ttrr'• .
rY� .'.7
.r t
1
:1 •1
1
I �
1 11� ♦.
1 r '
1
. y f •�
Y 1 l
1
ti
• ..1 t
r
,
1
w •• 4 r
Y C�'•
1� 1
rt
• r'.
1•
� 1 saJ
1
Y 1
xj A
14
i `5,t
r
•'trFrt�.: r Y � 'i i "tit {{{, llrr"
ar rA� •Sit"'+%.1 y, !'i+',: pi• ram \� r' i;i; ,1 • • .� � - r
1•
:f �•, r,
J• .
• h+' N
1 Fit. r 'i
• A
f
n
•�r. Gf4
t \ r
/ 1
i
.I .
/r •tt .
V
r it
.n'
,r�P r Y •
,.QTR
SITE LOCATION
SCALE: NONE
AIR TERMINAL UNIT SCHEDULE
MODEL
MATERIAL
MOUNTING
FINISH
SIZE
REMARKS
PHASE
Hp/A
NOTES Jar
EXPOSED SUPPLY -INSIDE BUILDING ENVELOPE
NONE
NONE
C403.2.7.2
FILTER SIZES
SQ/RECT SUPPLY -INSIDE BUILDING ENVELOPE
SIDE WALL DIFFUSER
SWD-1
TITUS.
30ORS
STEEL
SURFACE
WHITE
SEE DRAWINGS
BORDER TYPE 1
SIDE WALL GRILLE
SWG-1
TITUS
35ORL
STEEL
SURFACE
WHITE
SEE DRAWINGS
BORDER TYPE 1
EXPOSED SIDE WALL DIFFUSER
SWD-2
TITUS
30OFS
ALUMINUM
DUCT MOUNTED
WHITE
SEE DRAWINGS
ASD DAMPER EXTRACTOR
SUPPLY DIFFUSER SIZE
SIZE RANGE
8" X 6ll 200 CFM AND BELOW
10" X 8" ABOVE 200 CFM
COMMISSIONING PLAN
ALL COMMISSIONING OF HEATING,.. VENTILATION AND AIR CONDITIONING S
SYSTEMS AS
REQUIRED BY SECTI❑N C408 'SYSTEM COMMISSIONING" OF THE 2012 WASHINGTON STATE
ENERGY CODE (WSEC) SHALL BE PERFORMED BY EVERGREENL
L Cr THE
ACTIVITIES T❑ BE ACCOMPLISHED ARE PER E S
TI THE ECTI❑NS' LISTED IN THE
r
COMMISSIONING COMPLIANCE CHECKLISTs SHOWN BELOW,❑M COMPLETION ❑F
AT THE C P THE
ACTIVITIES REQUIRED FOR COMMISSIONING AS DEFINED BY SECTION C408 OF WSEC
THE COMMISSIONING COMPLIANCE CHECKLISTN WILL. BE REVIEWED WITH THE
BUILDING OWNER OR THE OWNERS REPRESENTATIVE AND THIS CERTIFICATION WILL
BE SIGNED AND DATED, THIS WILL SATISFY TO THE CODE OFFICIAL THAT THE REPORT
T
HAS BEEN ACCEPTED AS REQUIRED BY SECTION C408.1,2t1 OF WSEC,
COMMISSIONING COMPLIANCE CHECKLIST
Project
Information
Project Name:
Project Address:
Commissioning Authority:
Commissioning
Plan ® Commissioning Plan was used during construction and Included Items below
(Section • A narrative description of activities and the personnel Intended to accomplish each one
C408,111)
•
eas able criteria M ur I ria forP erformance
• Functions to be tested .
Systems
Balancing
(Section
C408,2r2)
Functional
Testing
(Se_tions
C40Bt2t3)
Supporting
PP 9
Documents
(Section
C408t1t3.2)
Commissioning
Report ® Preliminary Commissioning Report submitted to Owner and Includes Items below
(Section •
C408t1t2) Deficiencies found during testing required by this sectlan which have not been corrected at the time of
report preparation
. • Deferred tests, which cannot be performed at the time of report preperation due to climatic conditions.
® I hereby certify that all requirements for Commissioning have been
completed In accordance with the Washington State Energy Code,
Certification Including all Items above.
Building Orfner or �rfner's Representative Date
® Systems Balancing has been completed
•
Air and dronic systems are proportionately balanced In n manner to first minimize throttling losses
HY Y Pry Y InB
• Test ports are provided on each pump for measuring pressure across the pump
HVAC Equipment Functional Testing has been completed (Section C408t23.0
HVAC aui Ment has been tested to demonstrate the installation and
p
o eratioq P
n of components, systems and
sstem-b -system Interfacing re
cing relationships In accordance with approved
lyans and
ecif[cations
®VAC Controls Functional Testing has been completed (Section C408x2x3t2)
HVAC control h ve bee tested to ens re that control devices are
C2
ad5jueted an operate operate property.
Sequencer of ope ation hh ve been functionally tested to ensure they
operate Ir acc c1 -a ce wlt�i approved
Pans and s ecp{ficalons
PP
Economizers Functional Testing has been completed (Section C408.2x3x3)
Economizers operate In accordance with manufacturer's specifications
ns
Manuals record documents and traininghave been completed or are scheduled
P
System documentation has been provided to the owner or scheduled date
.. I
Record documents have been submitted to owner or scheduled dote__-.....................
• Training has been completed or scheduled dater________________________________________
RLE Cop
Permit ®�
REAWED
Pian review egprovai is subject to errors and omissions.
'
APPIROVFD
Approval of construction documents does not authorize
the violation of any adopted code or ordinance. Recolpt .
6
FEB - of approved Field Copy and conditions is acknowledged:.
•`. CIL � �'ctC.�li Dat®:
Iiil.owo olvi
City Of Tukwila
BUILDING DIVISION
EXHAUST FAN SCHEDULE
_ DUCT INSULATION TABLE
MANF.
' DUCT
THICKNESS
WSEC REQUIRED INSULATION
R -VALUES
WSEC 2012.
SECTION . ..
PHASE
Hp/A
NOTES Jar
EXPOSED SUPPLY -INSIDE BUILDING ENVELOPE
NONE
NONE
C403.2.7.2
FILTER SIZES
SQ/RECT SUPPLY -INSIDE BUILDING ENVELOPE
1"
R-13.
C403.2.7.2
EF 1
ROUND SUPPLY -INSIDE BUILDING ENVELOPE
1.511
R-3.3
C403.2.7.2
115
SUPPLY/RETURN/OSA-OUTSIDE BUILDING ENVELOPE
211
R-8.0
C403.2.7.2
BROAN
RETURN -INSIDE BUILDING ENVELOPE
NONE
NONE
C403.2.7.2 ex 2
w =
RELIEF
NONE REQUIRED.
J
aWC
EXHAUST
NONE REQUIRED
SUPPLY DIFFUSER SIZE
SIZE RANGE
8" X 6ll 200 CFM AND BELOW
10" X 8" ABOVE 200 CFM
COMMISSIONING PLAN
ALL COMMISSIONING OF HEATING,.. VENTILATION AND AIR CONDITIONING S
SYSTEMS AS
REQUIRED BY SECTI❑N C408 'SYSTEM COMMISSIONING" OF THE 2012 WASHINGTON STATE
ENERGY CODE (WSEC) SHALL BE PERFORMED BY EVERGREENL
L Cr THE
ACTIVITIES T❑ BE ACCOMPLISHED ARE PER E S
TI THE ECTI❑NS' LISTED IN THE
r
COMMISSIONING COMPLIANCE CHECKLISTs SHOWN BELOW,❑M COMPLETION ❑F
AT THE C P THE
ACTIVITIES REQUIRED FOR COMMISSIONING AS DEFINED BY SECTION C408 OF WSEC
THE COMMISSIONING COMPLIANCE CHECKLISTN WILL. BE REVIEWED WITH THE
BUILDING OWNER OR THE OWNERS REPRESENTATIVE AND THIS CERTIFICATION WILL
BE SIGNED AND DATED, THIS WILL SATISFY TO THE CODE OFFICIAL THAT THE REPORT
T
HAS BEEN ACCEPTED AS REQUIRED BY SECTION C408.1,2t1 OF WSEC,
COMMISSIONING COMPLIANCE CHECKLIST
Project
Information
Project Name:
Project Address:
Commissioning Authority:
Commissioning
Plan ® Commissioning Plan was used during construction and Included Items below
(Section • A narrative description of activities and the personnel Intended to accomplish each one
C408,111)
•
eas able criteria M ur I ria forP erformance
• Functions to be tested .
Systems
Balancing
(Section
C408,2r2)
Functional
Testing
(Se_tions
C40Bt2t3)
Supporting
PP 9
Documents
(Section
C408t1t3.2)
Commissioning
Report ® Preliminary Commissioning Report submitted to Owner and Includes Items below
(Section •
C408t1t2) Deficiencies found during testing required by this sectlan which have not been corrected at the time of
report preparation
. • Deferred tests, which cannot be performed at the time of report preperation due to climatic conditions.
® I hereby certify that all requirements for Commissioning have been
completed In accordance with the Washington State Energy Code,
Certification Including all Items above.
Building Orfner or �rfner's Representative Date
® Systems Balancing has been completed
•
Air and dronic systems are proportionately balanced In n manner to first minimize throttling losses
HY Y Pry Y InB
• Test ports are provided on each pump for measuring pressure across the pump
HVAC Equipment Functional Testing has been completed (Section C408t23.0
HVAC aui Ment has been tested to demonstrate the installation and
p
o eratioq P
n of components, systems and
sstem-b -system Interfacing re
cing relationships In accordance with approved
lyans and
ecif[cations
®VAC Controls Functional Testing has been completed (Section C408x2x3t2)
HVAC control h ve bee tested to ens re that control devices are
C2
ad5jueted an operate operate property.
Sequencer of ope ation hh ve been functionally tested to ensure they
operate Ir acc c1 -a ce wlt�i approved
Pans and s ecp{ficalons
PP
Economizers Functional Testing has been completed (Section C408.2x3x3)
Economizers operate In accordance with manufacturer's specifications
ns
Manuals record documents and traininghave been completed or are scheduled
P
System documentation has been provided to the owner or scheduled date
.. I
Record documents have been submitted to owner or scheduled dote__-.....................
• Training has been completed or scheduled dater________________________________________
RLE Cop
Permit ®�
REAWED
Pian review egprovai is subject to errors and omissions.
'
APPIROVFD
Approval of construction documents does not authorize
the violation of any adopted code or ordinance. Recolpt .
6
FEB - of approved Field Copy and conditions is acknowledged:.
•`. CIL � �'ctC.�li Dat®:
Iiil.owo olvi
City Of Tukwila
BUILDING DIVISION
EXHAUST FAN SCHEDULE
MARK
MANF.
MODEL
CFM
S.P.
VOLTS
PHASE
Hp/A
NOTES Jar
COOLING
HEATING
ELECTRICAL
WEIGHT
TOTAL
FILTER SIZES
NOTES
CFM
WC
CFM
EF 1
BROAN
L150
150
0.25"
115
1
1.4 A
LOCATED ON CEILI G
EF 2
BROAN
L150
150
0.25"
115
1 .
1.4 A
LOCATED ON CEILING
EF 3
BROAN
L150
150
0.25"
115
1
1.4 A
LOCATED ON CEILING
EF 4.
BROAN
L100
93
0.25"
115
1
1.1 A
LOCATED ON CEILING
NOTE: INTERLOCK W / LIGHTSWITCH BY ELECTRICAL CONTRACTOR
GAS. PACKAGE EQUIPMENT SCHEDULE
MARK
MANF.
MODEL
TONS.
AIRFLOW
SP
MIN. OSA
Motor
DRIVE
COOLING
HEATING
ELECTRICAL
WEIGHT
TOTAL
FILTER SIZES
NOTES
CFM
WC
CFM
Hp
STYLE
TOTAL
SEER
EER
INPUT
OUTPUT
AFUE
VOLTS
PHASE
M.C.A. ,
FIRE DAMPER
-�
FSD
FIRE/SMOKE DAMPER 020V POWER REQ.)
-®-'d
CEILING RADIATION DAMPER
sn
SD
BTUH
TO
T
BTUH
BTUH
(a/o)
M
-R- - - -R
(A)
LBS
NO. (LxWxD)
G
RTU 1
LENNOX
KGA090S4B
7.5
3000
0.5
600 '
2.00
BD
92,000
---
.11.0
150,000.
:. 120,000
80%
1 230
30
42.0
1004
4 (20" x 20" x 2")
1,2
RTU 2
LENNOX
KGA120S4M
10
4000
0.5
400
3.00.
BD
118,400
---
11.0
188,000
144,000
80%
230
30
46.0
1158
4 (20" x 24" x 2")
1,2.
RTU 3
LENNOX
KGA048S4D
4
1600
0.5
320
0.5.
DD
1 50,000.
13.0
11.0 -
65,000
52,000
80%
.230
3(7J
23.0
772
4 (16" x 20" x 7)
1
RTU 4
LENNOX
KGA060S4D
5
1 2000
0.5
400
0.75
DD
61,800
1 13.0
1 11.2
108,000
1 86,000
80%
230
30
25.0
810
4 (16" x 20" x 2")
1
REVISIONS
No changes shall be made to the scope
of Work without prior approval of
TLIicwila Building Division.
N0T�: Revisions will require a new plan submittal
. and may include additional plan review fees. I
SEr r% R ATC PER!,AIT
REQUIRED FOR:
R'Mechanical
RrE lectrical
[Plumbing
❑ Gas Piping
City of Tukwila
BUILDING DIVISION
/
GENERAL NOTES
DUCTWORK
1.1 ALL DUCT DIMENSIONS ON PLANA E CLE N "
R ARI 510E DIMENSIONS ADD TO -EAC
DIMENSION TO OBTAIN OUTSIDE DIMENSION. ADD 470 EACH DIMENSION IF H
DUCTWORK IS ON THE EXTERIOR OF BUILDING.
THE FIRST NUMBER ON ALL DUCT DIMENSIONS IS THE WIDTH AND THE SECOND
1. O
2 NUMBER IS THE HEIGHT.
MATERIALS WITHIN DUCTS O PLENUMS SHALL E
1.3
R HAVE AFLAME SPREAD RATING
LESS THAN 25 AND A FLAME SMOKE DEVELOPMENTT
RA ING LESS THAN 501 PER
IMC 602.2.1.
1.4
SEAL ALL TRANSVERSE JOINTS FOR DUCTWORK
WITH STATIC PRESSURE BETWEEN
1/2 INCHES AND 2 INCHES. DUCTWORK WHICH IS DESIGNED TO OPERATE AT
PRESSURES ABOVE 1/2 INCH WATER COLUMN STATIC
PRESSURE SHALL BE SEALED
IN ACCORDANCEWITH STANDARD RS -7. .
.5 ALL DUCT M A
1 AU ES G G PER ACN IMC 603-4.
1.6. ALL DUCT -
SUPPORTS PER SMACNA -IMC 603 10.
1
1.7
ATTACH DIFFUSERS AN GRILLE TO T - BAR D
GRI B R GRI PER R WA STATE &LOCAL CODES.
1.8
BALANCING DAMPERS ARE TO BE INSTALLED ON ALL BRANCH DUCTS OR DIFFUSERS.
INSULATION
2.1 INSULATE OR LINE DUCTWORK PER WA. STATE ENERGY AND MECHANICAL CODES.
2.2 INSULATE REFRIGERANT & CONDENSATE PIPING PER STATE & LOCAL ENERGY CODES.
GENERAL CONTRACTOR
3.1 GENERAL CONTRACTOR TOOV DE AND CUT OPENINGS PR I P NINGS FOR ALL ROOFTOP,
CEILING, FLOOR, AND WALL PENETRATIONS, INCLUDING WEATHERPROOF SEALING '
AND FIRE PROOF LINING PER IMC & IBC.
3.2 GENERAL CONTRACTOR TO VERIFY PENETRATION LOCATION AND DIMENSIONS
WITH ERL BEFORE FRAMING OPENINGS.
3.3
GENERAL CONTRACTOR PROVIDE ALL DEMOLITION, TOP R iPATCHING, AND PAINTING
AS REQUIRED FOR MECHANICAL WORK.
3.4 GENERAL CONTRACTOR TO PROVIDE ADEQUATE STRUCTURAL SUPPORT AS
REQUIRED FOR MECHANICAL WORK.
3
GENERAL CONTRACTOR TO PROVIDE ADEQUATE ENGINEERING .5 I Q GI RING AS REQUIRED FOR
MECHANICAL WORK.
R ,
3.6 GENERAL CONTRACTOR TO PROVIDE SERVICE ACCESS PER CODE TO ALL
MECHANICAL EQUIPMENT.'
3.7 GENERAL CONTRACTOR TO LEVEL ALL FACTORY CURBS PROVIDED BY ERL PROVIDE
ALL CANT STRIPS AND CURB INSULATION, AND SEAL AGAINST LEAKS.
GENERAL T P
3.8 R O PROVIDE IDE ALL CUTTING AND PATCHINGCEILING
OF T -BA R C I ING
AS REQUIRED FOR HVAC INSTALLATION.
3,9 GENERAL CONTRACTOR TO PROTECT ALL OPENINGS THROUGH FLOORS PROVIDED
FOR DUCTWORK INSTALLATION IN ACCORDANCE WITH TABLE 601 OF INTERNATIONAL
BUILDING CODE, WHERE REQUIRED BY SECTION 707 OF IBC.
ELECTRICAL
4.1 ERL TO INSTALL ALL LOW VOLTAGE CONTROL WIRING, CONDUIT WILL BE PROVIDED
BY ELECTRICAL CONTRACTOR.
RA OR.
4.2 ELECTRICAL CONTRACTOR TO PROVIDE ALL ELECTRICAL CONNECTIONS,
DISCONNECTS, AND STARTERS EQUIPMENT.
RS FOR MECHANICAL
4.3 ELECTRICAL CONTRACTOR TO VERIFY EQUIPMENT SIZES LOADS
QAND LOCATIONS
WITH ERL MECHANICAL PLAN AND WITH FIELD CONDITIONS.
4.4 ELECTRICAL RI L CONTRACTOR TO INTERLOCK BATHROOM ROOM E XHAUST FANS WITH LIGHT
IG T
SWITCH.
4.5 ERL TO PROVIDE 7 -DAY NIGHT SETBACK, PROGRAMMABLE TYPE T -STAT WITH
"CAPABILITY OF 60F DEADBAND.
BAN .
4.6 ERL TO VERIFY FINAL LOCATION OF THERMOSTAT WITH CUSTOMER.
4.7 ELECTRICAL CONTRACTOR TO PROVIDE ELECTRICAL GCFI OUTLET WITHIN 25 FT
OF EACH PIECE OF MECHANICAL EQUIPMENT.
PLUMBING
5.1 PLUMBING CONTRACTOR TO FURNISH AND INSTALL ALL GAS PIPING FOR
MECHANICAL EQUIPMENT PER CODE.
5.2 PLUMBING C014TRACTOR OFFSET VENTS 10 FEET MINIMUM FROM ALL HVAC FRESH
AIR INTAKES OR Z ABOVE HIGHEST POINT OF INTAKE, IMC 401.4.1.
5.3 CONDENSATE DRAINS FROM RTU BY ERI TO DRAIN WITHIN 12" OF UNIT.
CONDENSATE DRAINS FOR AIR HANDLERS BY PLUMBER.
ENERGY CODE COMPLIANCE
6.1 THE SUPPLY HEATING AND COOLING ENERGY TO EACH ZONE SHALL BE CONTROLLED
BY INDIVIDUAL THERMOSTATIC CONTROLS CAPABLE OF RESPONDING TO
TEMPERATURE WITHIN THE ZONE. AT A MINIMUM, EACH FLOOR SHALL BE CONSIDERED
AS A SEPARATE ZONE
6.2 OUTDOOR AIR SUPPLY, EXHAUST OPENINGS AND RELIEF OUTLETS FOR EQUIPMENT
GREATER THAN 300 CFM SHALL BE PROVIDED WITH CLASS 1A MOTORIZED DAMPERS
WHICH CLOSE :%UTOMATICALLY WHEN THE SYSTEM IS OFF PER WSEC/SEC SECTION
C402.4.5.2.
MECHANICAL CODE' COMPLIANCE
7.1 WHERE REQUIRED PROVIDE AUTOMATIC SHUTOFF ACTIVATED BY SMOKE DETECTORS
IN EACH SYSTEM DELIVERING HEATING OR COOLING AIR IN EXCESS OF 2000 CFM.
DETECTORS SHALL BE LOCATED IN THE. MAIN RETURN AIR PER IMC 606.
WA2012
SYMBOL LEGEND
SYMBOL
ABBV.
DESCRIPTION
®
DUCT SECTION SUPPLY
®
DUCT SECTION -.RETURN /EXHAUST
I "
RECTANGULAR DUCT
ROUND DUCT
FLEXIBLE DUCT
MVD
MANUAL VOLUME DAMPER
BDD
BDD
BACKDRAFT DAMPER
MD
MOTORIZED DAMPER.
-�
FD
FIRE DAMPER
-�
FSD
FIRE/SMOKE DAMPER 020V POWER REQ.)
-®-'d
CEILING RADIATION DAMPER
sn
SD
SMOKE DETECTOR
TO
T
THERMOSTAT
QS
S
SENSOR.
-R- - - -R
R
REFRIGERANT LINES r
-G- - - -G
G
NATURAL GAS LINES
®
CEILING DIFFUSER (SUPPLY)
®
CEILING DIFFUSER (RETURN/EXHAUST)
EXHAUST FAN (CEILING MOUNTED)
INLINE FAN
®
GORREeTiON
PROPELLER FAN
SIDEWALL DIFFUSER .
DUCT FITTING
®
ZD
ZONE DAMPER
UNIT TAG
VC.. 1
2
.
DUCT RISER
V
,o
N
_ O
-Y
M
W LfJ W
N
i
D � �
M
CfJ
N
Z
O
U
Z 0
'fit' W lz
V)
c�
O O Z
_J U
W �
M
CO O
o LL
J_
Z
W
LLJ (1)m
0 In
Q
O
e-
0
z
vJ O
Q
Q
L
Q F-
W
W 00
w H W W00
Z �
Z w U �.
°=�
� J U
LL = M
r -
z REVISIONS
C) NO DATE ITEM
1 02/12/16 PERMIT
N
�h
W
CITY OF TU EKWILA
W FEB 16 2016
PERMIT CENTER
DWG. BY:
GN
CHK. BY:
MG JS
JOB. NO.:
515244
SHEET:
•- el.�n3
. . 4.•.,