HomeMy WebLinkAboutPermit PG16-0010 - SAFEWORKS - GAS PIPING EMERGENCY REPAIRSAFEWORKS
365 UPLAND DR
PG16-0010
Citv of Tukwila
Department of Community Development
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206-431-3670
Inspection Request Line: 206-438-9350
Web site: http://www.TukwilaWA-Qov
PLUMBING/GAS PIPING PERMIT
Parcel No: 8836500070
Address: 365 UPLAND DR
Project Name: SAFEWORKS
Owner:
Name: TRIPLE H DEVELOPMENT LLC
Address: 1006 SPRAGUE ST, EDMONDS, WA,
98020
Contact Person:
PG16-0010
Name:
PETER CRELLEY
Address:
PO BOX 33370, SEATTLE, WA, 98133
Contractor:
2014
Name:
PRO STAFF MECHANICAL INC
Address:
PO BOX 33370, SEATTLE, WA, 98133
License No:
PROSTMI072NG
Lender:
2012
Name:
2012
Address:
Permit Number:
PG16-0010
Issue Date:
1/29/2016
Permit Expires On:
7/27/2016
Phone: (206) 361-0071
Phone: (206) 361-0071
Expiration Date: 7/2/2016
DESCRIPTION OF WORK:
EMERGENCY REPAIR: REPAIR EXISTING GAS PIPING AND PRESSURE TEST OF EXISTING GAS PIPING DAMAGED BY
FORK LIFT
Valuation of Work: $5,000.00 Fees Collected: $102.38
Water District: TUKWILA
Sewer District: TUKWILA SEWER SERVICE
Current Codes adopted by the City of Tukwila:
International Building Code Edition:
2012
National Electrical Code:
2014
International Residential Code Edition:
2012
WA Cities Electrical Code:
2014
International Mechanical Code Edition:
2012
WAC 296-466:
2014
Uniform Plumbing Code Edition:
2012
WA State Energy Code:
2012
International Fuel Gas Code:
2012
Permit Center Authorized Signature: IA L&I& Date:
I hearby certify that I have read and examined this permit and know the same to be true and correct. All
provisions of law and ordinances governing this work will be complied with, whether specified herein or not.
The granting of this permit does not presume to give authority to violate or cancel the provisions of any other
state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this
development permit and agree to the conditions attached to this permit.
Signature:
Print Nam6: Alo,,��)
Date: 1-7-9 — 16
This permit shall become null and void if the work is not commenced within 180 days for the date of issuance, or if
the work is suspended or abandoned for a period of 180 days from the last inspection.
PERMIT CONDITIONS:
1: ***PLUMBING/GAS PIPING PERMIT CONDITIONS***
2: No changes shall be made to applicable plans and specifications unless prior approval is obtained from the
Tukwila Building Division.
3: All permits, inspection records and applicable plans shall be maintained at the job and available to the
plumbing inspector.
4: All plumbing and gas piping systems shall be installed in compliance with the Uniform Plumbing Code and
the Fuel Gas Code.
5: No portion of any plumbing system or gas piping shall be concealed until inspected and approved.
6: All plumbing and gas piping systems shall be tested and approved as required by the Plumbing Code and
Fuel Gas Code. Tests shall be conducted in the presence of the Plumbing Inspector. It shall be the duty of
the holder of the permit to make sure that the work will stand the test prescribed before giving notification
that the work is ready for inspection.
7: No water, soil, or waste pipe shall be installed or permitted outside of a building or in an exterior wall
unless, adequate provision is made to protect such pipe from freezing. All hot and cold water pipes
installed outside the conditioned space shall be insulated to minimum R-3.
8: Plastic and copper piping running through framing members to within one (1) inch of the exposed framing
shall be protected by steel nail plates not less than 18 guage.
9: Piping through concrete or masonry walls shall not be subject to any load from building construction. No
plumbing piping shall be directly embedded in concrete or masonry.
10: All pipes penetrating floor/ceiling assemblies and fire -resistance rated walls or partitions shall be protected
in accordance with the requirements of the building code.
11: Piping in the ground shall be laid on a firm bed for its entire length. Trenches shall be backfilled in thin
layers to twelve inches above the top of the piping with clean earth, which shall not contain stones,
boulders, cinderfill, frozen earth, or construction debris.
12: The issuance of a permit or approval of plans and specifications shall not be construed to be a permit for, or
an approval of, any violation of any of the provisions of the Plumbing Code or Fuel Gas Code or any other
ordinance of the jurisdiction.
13: The applicant agrees that he or she will hire a licensed plumber to perform the work outlined in this permit.
14: All new plumbing fixtures installed in new construction and all remodeling involving replacement of
plumbing fixtures in all residential, hotel, motel, school, industrial, commercial use or other occupancies
that use significant quantities of water shall comply with Washington States Water Efficiency ad
Conservation Standards in accordance with RCW 19.27.170 and the 2006 Uniform Plumbing Code Section
402 of Washington State Amendments
PERMIT INSPECTIONS REQUIRED
Permit Inspection Line: (206) 438-9350
2000 GAS PIPING FINAL
9002 ROUGH -IN GAS PIPING
CITY OF TUKWILA
Community Development Department
Permit Center
6300 SouthcenterBlvd., Suite 100
Tukwila, WA 98188
http://www.TukwilaWA.jzov
Plumbing/Gas Permit No.
Project No.
Date Application Accepted:
Date Application Expires:
(For office use only
PLUMBING / GAS PIPING PERMIT APPLICATION
Applications and plans must be complete in order to be accepted for plan review.
Applications will not be accepted through the mail or by fax.
"Please Print"
SITE LOCATION
King Co Assessor's Tax No.: J `J 3 iv t7 c�0 7 O
�
Site Address:1/�
L J Vim-
Suite Number. "�
Floor:
Tenant Name:_ �A fc
G '
EAA`af?K S
New Tenant:
❑ ..... Yes..No
LF
PROPERTY OWNER
CONTACT
Name. iiuLe- 14 al.�
JT
Address: 1004, S t/ —
City �--- StatWA-
PERSON — person receiving all project
communication
Name:-
Address f-0. flx 333%
City: A 1 L9^ State: WN Zip: $13
Phone! -0L --N1,? —'oma ax: ?.o Z— 3 04vt
ail:
Valuation of Project (contractor's bid price): $
Scope of Work (please provide detailed information):
jZFQA4IR E- ->C Is 1) N 6, 6A<- P117)"6 t- f lzeSsvRr "fp-s--q or-
C�cir, 1►� c�
C�1�-s 'PfP1r� C,_
PLUMBING CONTRACTOR INFORMATION
Company Name!
Address:-) O. r5' ile 333�l
City: S ^, State: Zip:� J 3
Phone_ 36 Fax- —3 61, o
Co Z&11Q„kZ0Z.. G, Exp Date:
Tukwila Business License No.: S V5 r 3�
Building Use (per Int'l Building Code):
Occupancy (per Int'l Building Code):
Utility Purveyor: Water:
H: ApplicationsWortns-Applications On Line\2011 ApplicationsTlumbing Permit Application Revised 8.9.1 I.docx
Revised: August 2011
bh
Sewer:
Pagel of 2
Indicate type of plumbing fixtures and/or gas piping outlets being installed and the quantity below:
Fixture Type
Qty
Bathtub or combination
bath/shower
Dishwasher, domestic with
independent drain
Shower, single head trap
Sinks
Rain water system — per
drain (inside building)
Grease interceptor for
commercial kitchen (>750
gallon capacity)
Each additional medical
gas inlets/outlets greater
than 5
Atmospheric -type vacuum
breakers not included in
lawn sprinkler backflow
protections (1-5)
Fixture Type
Qty
Bidet
Drinking fountain or water
cooler (per head)
Lavatory
Urinal
Water heater and/or vent
Repair or alteration of
water piping and/or water
treatment equipment
Backflow protective device
other than atmospheric -
type vacuum breakers 2
inch (51 mm) diameter or
smaller
Atmospheric -type vacuum
breakers not included in
lawn sprinkler backflow
protections over 5
PERMIT APPLICATION NOTES -
Fixture Type
Qty
Clothes washer,
domestic
Food -waste grinder,
commercial
Wash fountain
Water closet
Industrial waste
treatment interceptor,
including trap and vent,
except for kitchen type
grease interceptors
Repair or alteration of
drainage or vent piping
Backflow protective
device other than
atmospheric -type
vacuum breakers over 2
inch (51 mm) diameter
Gas piping outlets
Fixture Type
Qty
Dental unit, cuspidor
Floor drain
Receptor, indirect waste
Building sewer and each
trailer park sewer
Each grease trap
(connected to not more
than 4 fixtures - <750
gallon capacity
Medical gas piping
system serving 1-5
inlets/outlets for a specific
as
Each lawn sprinkler
system on any one meter
including backflow
protection devices
Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject
to possible revision by the Permit Center to comply with current fee schedules.
Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation
The Building Official may grant one extension of time for an additional period not to exceed 180 days. The extension shall be requested in writing
and justifiable cause demonstrated. Section 103.4.3 International Plumbing Code (current edition).
I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER
PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT.
BUILDING
Print
Date: Z
Day Telephone: Z04 — 3 to 0tF7 i
Mailing Address:E. e. Bo,)c 3337g Se Al -f E W/4 q6133
City state Zip
H:Wpplications\Forms-Applications On LineL01I ApplicationsWlumbing Permit Application Revised 8-9-1 Ldoex
Revised: August 2011
bh
Page 2 of 2
DESCRIPTIONS
PermitTRAK
PAID
$102.38
PG16-0010 Address: 365 UPLAND DR
Apn: 8836500070
$102.38
GAS
$97.50
PERMIT ISSUANCE BASE FEE
R000.322.100.00.00 0.00
$32.50
PERMIT FEE
R000.322.100.00.00 0.00
$65.00
TECHNOLOGY FEE
$4.88
TECHNOLOGY FEE
TOTAL FEES PAID BY RECEIPT: R7541
R000.322.900.04.00 0.00
$4.88
$102.38
Date Paid: Friday, January 29, 2016
Paid By: PRO STAFF MECHANICAL INC
Pay Method: CHECK 15576
Printed: Friday, January 29, 2016 2:44 PM 1 of 1
CRSYS7EM5
1K-
INSPECTION RECORD 1(0
Retain a copy with permit
INSPECTION NO. PERMIT N0.
CITY OF TUKWILA BUILDING DIVISION
6300 Southcenter Blvd.., #100, Tukvvila. WA 98988 (206) 431-3670
Permit Inspection Request Line (206) 438-9350
Proj t.
5aM�a V-�
Type of Inspeci,ion: 11
VQSF(Kci
Adrs: � �� � ��
A
Date Called:-
Special Instru tions:
Sri i a v� hep I�
Date Want(d: a.m.
b p.m.
Requester:
Phone No,._
26- S 7 7
IInspector: j IDate: —t / —[
REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be
paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection.
INSPECTION RECORD
Retain a copy with permit P�i6��10
I N S P1tTtTF0N N0. PERMIT N0.
CITY OF TUKWILA BUILDING DIVISION
6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670
Permit Inspection Request Line (206) 438-9350
Proj ct:
Type of Inspectiop:
IW
a
A dress:
Date Called:
6 V0 eidr.
Special- Instructions:
Date Wanted: a.m.
p.m.
t� �c��vtG(Gt.G�
Requester: _
%)I 't Qre l .rye-
Phone No:
X77
S �� h-5"71-01eq
4
nspector:
El REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be
paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection.
PRO STAFF MECHANICAL INC
Safety & Health
Washington State Department of
Labor & Industries
PRO STAFF MECHANICAL INC
Home Espanol Contact
Search L&I
Page 1 of 2
A-% Index Help My Secure 1 -RI
Claims & Insurance Workplace Rights Trades & Licensing
Owner or tradesperson PO BOX 33370
SEATTLE, WA98133
Principals 206-361-0071
ALMO, LEONARD LEE, PRESIDENT KING County
ALMO, PENNY H, VICE PRESIDENT
Doing business as
PRO STAFF MECHANICAL INC
WA UBI No. Business type
601 038 859 Corporation
Governing persons
LEONARD
ALMO
PENNY H ALMO;
License
Verify the contractor's active registration / license / certification (depending on trade) and any past violations.
Construction Contractor Active.
..................._......................................................
Meets current requirements.
License specialties
GENERAL
$1,000,000.00
License no.
PROSTMI072NG
Effective — expiration
Effective date
08/07/1993— 07/02/2016
06/30/2014
Bond
.................
Expiration date
DEVELOPERS SURETY & INDEM CO
$12,000.00
Bond account no.
799707C
Received by L&I
Effective date
01/26/2009
01/14/2009
Expiration date
Until Canceled
Insurance
.............................
American Economy Insurance Co
$1,000,000.00
Policy no.
26CCO06951
Received by L&I
Effective date
06/22/2015
06/30/2014
Expiration date
06/30/2016
Insurance history
Savings
No savings accounts during the previous 6 year period.
Lawsuits against the bond or savings
https:Hsecure.Ini.wa.gov/verify/Detail.aspx?UBI=601038859&LIC=PROSTMI072NG&SAW= 1/29/2016