Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Permit PG16-0012 - MANILA SUNSET - SINKS AND CONNECTIONS
MANILA SUNSET 3 07 TUKWIIA PKWY PG16-0012 City of Tukwila • Department of Community Development • 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Inspection Request Line: 206-438-9350 Web site: http://www.TukwilaWA.gov PLUMBING/GAS PIPING PERMIT Parcel No: 0223000010 Permit Number: PG16-0012 Address: 307 TUKWILA PKWY Issue Date: 7/7/2016 Permit Expires On: 1/3/2017 Project Name: MANILA SUNSET Owner: Name: BETA HOLDINGS LTD Address: 18827 BOTHELL WAY NE, BOTHELL, WA, 98011 Contact Person: 2015 Name: TERRY FLETCHER Address: 1217 4TH AVE N, KENT, WA, 98031 Contractor: 2014 Name: INTERSTATE INDUSTRIES INC Address: 12235 SE 199th ST, KENT, WA, 98031 License No: INTERII873D7 Lender: 2015 Name: 2015 Address: Phone: (206) 679-3268 Phone: (206) 387-2364 Expiration Date: 3/27/2017 DESCRIPTION OF WORK: DEMO OUT EXISTING SINKS AND RESIDENTIAL APPLIANCES AND REINSTALL NEW SINKS AND CONNECTIONS INCLUDES INSTALLATION OF A GREASE INTERCEPTOR. Valuation of Work: $3,500.00 Fees Collected: $773.74 Water District: TUKWILA Sewer District: TUKWILA Current Codes adopted by the City of Tukwila: International Building Code Edition: 2015 National Electrical Code: 2014 International Residential Code Edition: 2015 WA Cities Electrical Code: 2014 International Mechanical Code Edition: 2015 WAC 296-466: 2014 Uniform Plumbing Code Edition: 2015 WA State Energy Code: 2015 International Fuel Gas Code: 2015 Permit Center Authorized Signature: Date: I hearby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regula g construction or the performance of work. I am authorized to sign and obtain this development permi agree to the con itions attached to this permit. Signature: n� Date: Print NaML/ �-� l ! Yll F �r7l�cJw� This permit shall become null and void if the work is not commenced within 180 days for the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. PERMIT CONDITIONS: 1: The ENDURA grease interceptor shall be installed and maintained per manufacturer's specifications. 2: ***PLUMBING/GAS PIPING PERMIT CONDITIONS*** 3: No changes shall be made to applicable plans and specifications unless prior approval is obtained from the Tukwila Building Division. 4: All permits, inspection records and applicable plans shall be maintained at the job and available to the plumbing inspector. 5: All plumbing and gas piping systems shall be installed in compliance with the Uniform Plumbing Code and the Fuel Gas Code. 6: No portion of any plumbing system or gas piping shall be concealed until inspected and approved. 7: All plumbing and gas piping systems shall be tested and approved as required by the Plumbing Code and Fuel Gas Code. Tests shall be conducted in the presence of the Plumbing Inspector. It shall be the duty of the holder of the permit to make sure that the work will stand the test prescribed before giving notification that the work is ready for inspection. 8: No water, soil, or waste pipe shall be installed or permitted outside of a building or in an exterior wall unless, adequate provision is made to protect such pipe from freezing. All hot and cold water pipes installed outside the conditioned space shall be insulated to minimum R-3. 9: Plastic and copper piping running through framing members to within one (1) inch of the exposed framing shall be protected by steel nail plates not less than 18 guage. 10: Piping through concrete or masonry walls shall not be subject to any load from building construction. No plumbing piping shall be directly embedded in concrete or masonry. 11: All pipes penetrating floor/ceiling assemblies and fire -resistance rated walls or partitions shall be protected in accordance with the requirements of the building code. 12: Piping in the ground shall be laid on a firm bed for its entire length. Trenches shall be backfilled in thin layers to twelve inches above the top of the piping with clean earth, which shall not contain stones, boulders, cinderfill, frozen earth, or construction debris. 13: The issuance of a permit or approval of plans and specifications shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the Plumbing Code or Fuel Gas Code or any other ordinance of the jurisdiction. 14: The applicant agrees that he or she will hire a licensed plumber to perform the work outlined in this permit. 15: All new plumbing fixtures installed in new construction and all remodeling involving replacement of plumbing fixtures in all residential, hotel, motel, school, industrial, commercial use or other occupancies that use significant quantities of water shall comply with Washington States Water Efficiency ad Conservation Standards in accordance with RCW 19.27.170 and the 2006 Uniform Plumbing Code Section 402 of Washington State Amendments PERMIT INSPECTIONS REQUIRED Permit Inspection Line: (206) 438-9350 2000 GAS PIPING FINAL 8004 GROUNDWORK 1900 PLUMBING FINAL 9002 ROUGH -IN GAS PIPING 8005 ROUGH -IN PLUMBING 9001 UNDERGROUND CITY OF TUKW 1 Community Developmen, Department Permit Center • 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 ]htip://www.Tukwi]aWA.gov SITE LOCATION Plumbing/Gaz rermit No. Project No. Date Application Accepted: Date Application Expires: For office use onl ) PLUMBING / GAS PIPING PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. "Please Print* j L King Co Assessor's Tax No.: ©2, 7- 3 6 D - Site Address: �� ` �^ 1��1 I �w Suite Number: Floor:_ Tenant Name: ►' \°`'I^t IGS _`�,G-V" SG New Tenant: ' ,....Yes ❑..No PROPERTY OWNER Name: ���� /�v I S Address:,V City: State: W)� Zip:n0k CONTACT PERSON - person receiving all project communication Name: Address: Tk n V, N. City: - State: W�- Zip:9,,Y.3/ l Phone: �U 6 _ 67q 3 % Fax Email: vv A`f"C✓c,L G PLUMBING CONTRACTOR INFORMATION Company Name:v�'(�e Address: (-7 %A A vL- City: e State: l� Zjp.99,g3 Phone:2G6 7j k- 7 23 ( fax: Contr Reg No.: h-rr,Y t 15?3 b Exp Date: 3117 I Tukwila Business License No.: Q u S -0'7( 644 e3 Valuation of Project (contractor's bid price): $ 3-500 ` 00 Scope of Work (please provide detailed information): 6 �9,e- O-�C (Z�SIrrtG��T(IJ /3-`PF)%"C.wt�5 6L -IJ ,"e-1'-sT,Altw %/ SF- S i,�-- S o-(,,4 C o ]n -� t:_c T i o n.s Building Use (per Int'l Building Code): Occupancy (per Int'l Building Code): Utility Purveyor: Water: Sewer: H:\Applications\Forms-Applications On Line\2011 Applications\Plumbing Permit Application Revised 8-9-11.docx Revised: August 2011 Page] of 2 bh Indicate type of plumbing fixtures and/o- ; piping outlets being installed and the quanti+ low: Fixture Type Qty Bathtub or combination bath/shower , '�[ Dishwasher, domestic with independent drain Shower, single head trap Sinks i I Rain water system — per drain (inside building) Grease interceptor for commercial kitchen (>750 gallon capacity) I Each additional medical gas inlets/outlets greater than 5 Atmospheric -type vacuum breakers not included in lawn sprinkler backflow protections (1-5) Fixture Type Qty Bidet Drinking fountain or water , '�[ cooler (per head) Lavatory Urinal Water heater and/or vent i I Repair or alteration of water piping and/or water treatment equipment Backflow protective device other than atmospheric - type vacuum breakers 2 inch (51 mm) diameter or smaller Atmospheric -type vacuum breakers not included in lawn sprinkler backflow protections over 5 PERMIT APPLICATION NOTES - Fixture Type Qty Clothes washer, domestic , '�[ Food -waste grinder, commercial Wash fountain Water closet Industrial waste treatment interceptor, including trap and vent, except for kitchen type grease interceptors Repair or alteration of drainage or vent piping Backflow protective device other than atmospheric -type vacuum breakers over 2 inch (51 mm) diameter Gas piping outlets Fixture Type Qty Dental unit, cuspidor Floor drain , '�[ Receptor, indirect waste Building sewer and each trailer park sewer Each grease trap (connected to not more than 4 fixtures - <750 gallon capacity Medical gas piping system serving 1-5 inlets/outlets for a specific gas Each lawn sprinkler system on any one meter including backflow protection devices Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation The Building Official may grant one extension of time for an additional period not to exceed 180 days. The extension shall be requested in writing and justifiable cause demonstrated. Section 103.4.3 International Plumbing Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING AGENT: Signature: Print Name: gg Mailing Address: /2, t7 Day Telephone City Date: '�_ �'-l6 236''/ State Zip H:\Applications\Forms-Applications On Line\2011 Applications\Plumbing Permit Application Revised 8-9-1 I.docx Revised: August 2011 Page 2 of 2 bh DESCRIPTIONS PermitTRAK ACCOUNT QUANTITY_ 1 $672.21 PG16-0012 Address: 307 TUKWILA PKWY Apn: 0223000010 $672.21 GAS $139.50 PERMIT ISSUANCE BASE FEE R000.322.100.00.00 0.00 $32.50 PERMIT FEE R000.322.100.00.00 0.00 $107.00 PLUMBING $500.70 PERMIT FEE R000.322.100.00.00 0.00 $234.10 PERMIT ISSUANCE BASE FEE R000.322.100.00.00 0.00 $32.50 PERMIT FEE R000.322.100.00.00 0.00 $234.10 TECHNOLOGY FEE $32.01 TECHNOLOGY FEE TOTAL FEES PAID BY RECEIPT:•. R000.322.900.04.00 0.00 $32.01 Date Paid: Thursday, July 07, 2016 Paid By: INTERSTATE INDUSTRIES INC Pay Method: CHECK 5323 Printed: Thursday, July 07, 2016 11:42 AM 1 of 1 EANAV V?= SYSTEMS DESCRIPTIONS PermitTRAK $101.53 PG16-0012 Address: 301 TUKWILA PKWY Apn: 0223000010 $101.53 GAS $34.88 PLAN CHECK FEE 11000.322.103.00.00 0.00 $34.88 PLUMBING $66.65 PLAN CHECK FEE ,TOTAL FEES .. 1 11000.322.103.00.00 0.00 $66.65 $101.53 Date Paid: Monday, February 08, 2016 Paid By: INTERSTATE INDUSTRIES Pay Method: CHECK 5165 Printed: Monday, February 08, 2016 12:02 PM 1 of 1 RWrsrenns INSPECTION RECORD Retain a copy with permit W1 2 INS ION N0. PERMIT NO. CITY OP TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Project:Ty 5,;r � of Inspection: m a)AI L Address: '30-7agw&4w' Date Called: Special Instructions: Date Wante / a. 11- G �lt p.m. lKe—queste(-. Phone No: nApproved per applicable codes. Corrections required prior to approval. M M ENTS: Dater ❑ REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. INSPECTION RECORD Retain a copy with permit's INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-367 Permit Inspection Request Line (206) 438-9350 Project: Type of Inspection: Address: Otu)- Date Called: Special instructions: Date Wanted: a. )z & A; Requester: Phone No: INApproved per applicable codes. Corrections required prior to approval. COMMENTS: Inspector: Date: F] REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. INSPECTION RECORD Retain a copy with permit kt�iz,- �-a412, INSPECTION N0, PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Project• no) LA �� tel— Ty of Inspection: gn13 &- L - Address: Date Called: Special Instructions: Date Wanted: Requester: Phone No: FlApproved per applicable codes. Corrections required prior to approval. Inspector: Date: El REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. El INSPECTION RECORD Retain a copy with permit �� Z INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Project: A,-JILA S,rAJS&7-- Type of Inspection: 6 Address: 3cr7 Xwi LA �. Date Called: Special Instructions: a.m. Date Wanted:ke. L 2 _ Requester: Phone No: Approved per applicable codes. Corrections required prior to approval. Inspector: Date: REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. INSPECTION RECORD Retain a copy wit , ) Ih permit,` �CV/� PECTION NO. PERMIT N0. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Project: .�9AJII-A `�1i��Ey' TIF Inspection: 4 Al 66S IPJ IiiAG- Address:Date 30-7 421 i1 ,//�� &) Called: Special Instructions: Date Wan a.m. %� 1Z p.m. Requester: rey Phone No: MON' Inspector: Date:0 f REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. INSPECTION RECORD r6-) Retain a copy with permit jZr1(` 1001 I P ION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Project:T,Yge 4n.►I ofS' of Inspection: K0 U6 Iq - JAf 6ASIA(C- Address: ,0% P Y UJ Date Called: Special Instructions: Date Wan ed a.m. /� p.m. Requester: Phone No: Inspector: Date: REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. :TION RECORD. copy with permt PERMIT N0. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Project: MAW) L 9637— Ty of Inspection: u /W s p n� Address: ) Date Called: Special Instructions: Date Wantesf:f� , a. �f P.M. Re ter: q'/ Phone No: Z6- 779- /9-, Cr�Lc. �` leve REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. INSPECTION RECORD Retain a copy with permits"�z IN cC+ION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, 'rukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 t._ l Approved per applicable codes. LJ Corrections required prior to approval. (Inspector I Date+�_(�i s' � REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. INSPECTION RECORD � I Gly-Do�2 Retain a copy with permit CTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd.., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Project: Type of Inspection: LA D 0 Address: Date Called: f 7 0'? 711aJILAl Special Instructions: Date Wanted: / 7 �� /G p.m. Requester: CrA Of Phone No: Zo-77��1�9g nApproved per applicable codes. 1:1 Corrections required prior to approval. ❑ REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. INSPECTION RECORD Retain a copy with permit FffyI6,0012 INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Project: Type of Inspection: (2644,0 P YWA�JIIA S17 12th Address: Date Called: 30"7 Tu I u-1 PKtJ Special Instructions: Date Want da.m '7P1:116 p.m. Regyester� A &—w �—t'l Phone No: 6-77 " Approved per applicable codes. L: Corrections required prior to approval. Inspector: / (Date: 7111 A: iT7.A CO REINSPECTION FEE REQUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. ON VEW! Noritz NC1991-OD Commercial Vodels for Outdoor Installations BTU input range from 16,000 up to 199,900 BTUh Maximum flow rate capacity of up to 9.8 GPM Part of Noritz America's line of ProTough products for outdoor {-OD} installations Heat exchanger manufactured with commercial grade copper, 25% thicker piping than standard models Features an outdoor vent design that does not require additional venting Iroduct: NC1991-OD Commercial Water Heater Aodel#: NC1991-OD Availability: February 23, 2012 a0RRECTON LTR# 2' . ankless ' .ankless for Professionals F/,� �� / O0 (n RECEIVED CITY OF TUKWILA PERMIT CENTER Specifications: Performance/Dimensions a/ (�Ci f31 cc B1M Range: i 99,9oo to 16,ow 67Uh Max Hoc water Capacity: up to 9.8 gpm Dimensions: 23.6'x 13.5'x9.4' Warranty: 5 years Heat Fschamtw/5 yews Parts G 771?•i d� NC1991-OD l °.+trc* Fsoi FMWGS xAEOiTOYOF fA,� NC19Qt-0O R �R'ROL'7I_R Ifik� xD YlllfJt R7,Ff 21'65.mi 65'.r AFEf 72 {Yam Accessories Wcic Connect ? Cord (§QC 2) Noritz Isolation Valves (#IK -WV -200) Recess Box (or OD Model (!RB -700-1) Available APH12012 t ` N2Flow External System Controller Anti -Scale System COMING SOON! (#H2F) Noritz Americas"" Corporation 11160 Grace Ave., Fountain Valley, California 92708 Phone: (714) 433-2905 Fax: (714) 241-1514 www.noritz_com xtke WARNING! DO NOT PRESSURE TEST. RISK OF SER1OU51N uRY, As a plumbing appurtenance your Endura grease interceptor MUST be isolated from the drainage system in the event that final drain testing or other system Pressure testing is required. DO NOT under any circumstances subject your interceptor to pressure test (Air, Water or Otherwise). This action will result in damage to the unit, invalidate your warranty and could cause serious bodily injury. AVERTISSEMENT ! NE PAS SOUMEn'RE A UN ESSA1 DE PRESSION. RISQUE DE BLESSURE GRAVE. f. ADVERTENCIA! NO REA=R PRUEBAS DE PRESTON. RIESGO DE LESIOhIES GRAVES, En tant qu'accessoire de plomberie, votre w "Como un accesorio de plomeria, el intercepteur de graisse Endura ppR etre interceptor de grasa Endura DEBE estar isole du systeme de drainage advenant qu;oa aislado del sistema de drenaje en vaso de doive proceder a un essai final du drain ou a que se requiera Una prueba de drenaje final toutautre essai de pression du systeme. Vous ne devex en At1CUN cas soumettre votre u otras pruebas de pre5i6n del siszema. En NtNGUN caro someta su interceptor a intercepteur a un essai de pression (d'air, pruebas de presi6n (aire, aqua u otras)_ effet ou autre). Un tel essai aura pour Esta acd6n dara tomo resultado dafios a et%t de 1 endommager, sans compter qu ll la unidad, la invalidad6n tie su garantia y annulera votre garantie et quasi pourr_it posibles lesiones corporates graves. entrainerdes blessurescorporelles graves h• Sizing i F mopOR Sink Sizing .- For Grease Interceptor sizing, please reference the Sizing Guide or the Plumbing & E4� PS US/GPM Drainage institute Standard PD1 -G 101. without a properly sized flow control, the flow through the interceptor may exceed the rating of the unit, causing lower efficiencies 84 22 and allowing grease to pass through the interceptor into the downstream piping, Be142 careful that you do not confuse liquid ca 37-5 q capacity and flow capacity. Liquid capacity is 170 rated in titres or gallons while flow capacity is rated in gpm (gallons per minute) or L/ 45 sec (litres per second). If sizing indicates that a larger Grease interceptoris required, you maybe able to 0 0 o 0 compromise to a smaller unit by adopting to a 2 minute drain down time in your sizing calculation. Although; the smaller unit will be less a Take the volume of water produced by the caoacity of a smaller unit will dictate the cleaning frequencxP nsive, the grease number of hose bibs (ie 1.5-2.0 qpm per 3/4" Y required. faucet} Visit our website for our easy to use online GI Sizing Calculator. 3Sizing Calculator www.EnduraGiCalculatorcom STEP J FORMULA 1 I Determine cu77 bic content of fixture by multiplying length x width x depth 2 Determine capacity in gallons. 1 gallon = 231 cubic inches 3 Determine actual drainage load. The fixture is normally filled to approximately 75% of capacity with water as the items being washed displace about 25% of the total fixture content Actual drainage load = 75%offixture capacity 4 Determine flow rate and drainage period. Ineneral, good practice dictates a one minute drainage pe- riodghowever, where conditions permit, a two minute drainage period is acceptable. Drainage period is defined as the actual time required to completely drain the fixture. Flow rate = ActuaDrain age Load Drainage Period 5 Select Interceptor. From Table 8 select the interceptor with a flow rating at least equal to the calculated flow rate. When the calculated flow rate falls between two sizes, select the larger of the two PDi Size Symbol Flow Rate US Gallons per Minute (GPM) Flow Rate Liters per Second (CPS) Grease Capacity Pounds (Lbs) Grease Capacity Kilograms (Ki 4 7 Some municipalities require a sampling port to monitor effluent quality. if ����HEN the unit is on the floor, or semi -recessed into the floor, a deanout tee can be installed downstream of the Grease Interceptor_ If the unit is installed in the floor, a backwater with its flapper removed, makes an effective collection Port- Like the FCD the backwater valve can be extended to finish floor level using a sleeve kit. 4 7 .25 .44 $ 14 3.63 6.35 EXAMPLE A sink 24'long by 20'wide by 12'deep. Cubic content, 24 x 20 x 12 = 5,760 cubic inches (61.0 x 50.8 x 30.48 cm3 ) Contents in gallons: 5,760 / 231 = 24.9 gallons (94,451.42 / 1,000 = 94.45 litres) Actual drainage load: .75 x 24.9 = 18.7 gallons (0.75 x 94.45 = 70.84 litres) Calculate flow rate for one minute drainage period: 18.7 / 1 = 18.7 g.p.m. flow rate Calculate flow ate for two minute age period: 18.7/2= 9.4g.p.m.;(owrate (70.84 / 2 min. = 35.42 l.p_m.) For a one minute drainage period: 18.7 g.p.m. (70.84 l.p.m.) flow rate = 20 g.p.m. G.I. For a two minute drainage period: 9.4 9 -P.M. (35.42 l.p.m.) flow rate = 10 g.p.m. G.I. Interceptors 10 15 20 25 35 50 70 15 20 25 35 50 63 .95 1.26 1.58 2.20 3.16 20 30 40 50 70 100 9.07 13.61 18.14 22.68 31.75 45.36 -2- Grease Interceptors must have a vented waste, sized in accordance with local code requirements for venting interceptors to retain a water seal and prevent siphoning. most codes dictate that to vents be installed, one upstream and one downstream of thL, grease interceptor. The upstream vent must not be placed between the air intake and the grease interceptor. STOP Correct Size? Verifythatyou have purchased the correct sizelca" of interceptor foryourication. Visit www.SizeMyGi.net and use our"Quick Sizing Chart- or use the formula (Pg 2), Installation Congratulattunns on your purchase of the Endura Crease Interceptor. This product was designed and built to last and comes with a I 0 -year warranty.* Proper installation of a grease interceptor is critical to its efficient operation. Even the best designed grease interceptor evill not operate efficiently if installed incorrectly All installation recommendations are subject to the approval of the local code authority having jurisdiction. The Endura Grease interceptor may be installed on the floor, partially in the floor, or fully recessed below the floor to best suit the situation. Whichever installation configuration is used, make sure you locate the grease interceptor in an area that allows for ease c f maintenance. Placement should allow the cover to be easily removed for cleaning. A minimum clearance is required above the cover ofthe Grease interceptor to allow removal of the internal battles for a complete cleanout (7/10/15,20125/35 GPM -15', 25 GPM LO -5" 50 GPT/ -21-). With the cover removed, all internal surfaces should be visible. The Endura Grease Interceptor is marked with "IN and OUT"above the connections to ensure the grease interceptor is ins' tatted in the right direction. The grease inte,-ceptor should be installed as Close as possible to the fixture fs) being served, as every foot of piping between the grease source and the interceptor is unprotected and a potential source for grease build-up. installations requiring long runs 01010C [exceeding 25 feet (8m) F to reach the interceptor are to be avoided.This precaution will reduce the possibility of the pipeline becoming clogged with grease before reaching the grease interceptor. Grease waste lines should be piped at a minimum slope of 1/4 inch per foot (6mm per 304mm) to maintain flogs in the drain line. 'Valid only when the warranty card is filled out and returned to the manufacturer (Pg. 24). UJU[I Dimension aPpropriee? Assurez nous d`avoir achetela dimens'tonlcapacite d intercepteur qui convienta votre installation. Visitez www.SizeMyG[.net et consultez notre << Tableau de selection rapide de la tailie )) ou faites le calcul suivant (Pg 3). Installation Felicitations pour votre achat de Vintercepteur de graisse Endura. Ce produit a06 consu et construit pour durer et est livre avec une garantie de 10 ans.',' Onstallation adequate dun intercepteur de grilse est critique z son bon fonctionnement- Meme Iintercepteur de graisse le mieux conCu ne fanctionnera pas efficacement si► est instaile mcor ectt meni. est les recommandations d'installation sont sujettes A Papprobation des autorites competentes selon les codes locaux. Untercepteur de graisse Endura peut etre install& sur to plancher, partieltement dans le plancher, ou cgelon mpletement en retrait sous le plancher, s la situation qui convient le mieux Quelle que salt la configuration utilis&e, assurez-vows d installer Iintercepteur dans un endmit qui en facilitera I'entretien. L'emplacement de Iintercepteur dolt permettre d'enlever facilement le couvercle pour (e nettoyage, avec un degagement minimum de (7/10/15/20/25/35 GPM - 15 pouces, 25 GPM LO - 5 pouces, 50 GPM - 21 pouces au-dessus de i'intercepteur afin que Ilan puisse retirer les chicanes inter'ieures pour un nettoyage complet. Lorsque le couvercle est retire, toutes les surfaces internes doivent etre visibles non seulement pour accdder b 1'intercepteur pour le nettoyer mals aussi Pour inspector i'inteneur en cos de probl@me. Untercepteur de graisse Endura est marque c(IN)) et aOUTn audessus des raccords pour indicluer fa bonne direction d'installation. Untercepteur de graisse devrait etre install& aussi pr6s que possible de 1'appareil (ou des appareils) de piornberie desservi(s) puisque chaque pied de tuyauterie entre la source de graisse et #'intercepteur est non Prot&ge et constitue un site potentiel d'accumulation de graisse. Evitez les installations necessitant de grandes longueurs de tuyauterie [plus de 25 pieds (8 m)) afin de r&duire la possibilit@ d'obstruction avant que la graisse n'at-teigne lintercepteuc Les tuyaux d'evacuatfon de graisse usee devraient etre poses avec une pence minimum de 114 papar pied (6 mm par 3o crn) pour maintenir une viCsse d'ecoulementsufrasanre dans le tuyau 'Valideseulement torsque la carte de garantle a ete remplie en retournee (pg. 24). -5- UALTO-, eEs del Lama no N coaecto? Verifique que haya comprado el interceptor de tarsal -o y capacidad corrector para su aplicaci6n. Visite wWw.SizeMyGl.net y use nuestra tabla de tarnahos de referencia rapida ("Quick Sizing Chart") o la tarmula que se indica mas abaJo, (pig_ 4). Felicitaciones por su compra del interceptor de grasa Endura. Este producto fue diseriado y fabricado para durar y viene con una garantda de `Ick afios.* la instalaci6n adecuada del interceptor de grass es fundamental para su buen fundonamiento_ Inclusa of interceptor de grasa que posee el mejor diseno no funcionara de manes sicierre si se instala incorrec-tamente. Todas las recomendaciones de instalad6n estan sujetas a la aprobacidn de is autoridad local que tenga jurisdicci6n. El interceptor de grasa Endues se puede instaiar sobre el piss, parcialmente en ei piso o se puede empotrar par completo debajo del piso, seg6n sea to mas conveniente en sada caro_ Cualquiera sea fa configurad6n de instalacidn que utifice, aseg6rese de colocar el interceptor de grasa en un area que permita un facil mantenimiento. La ubicaci6n debe permitir que la taps se pueda retirr facilmente Para su lr,-npieza. 5e necesita un espacio fibr= minima sabre fa parte superior del interceptor de grana para poder retirar las deffectores internos Para una limpieza cornpfeta (7/10/15/20/25/35 GPM - 15" 25 GPM LO -5" 50 GPM - 21"1. Cuando la tapa se retira, todas las superficies iniernas deben quedar visibles. El 'interceptor de grass "Endura tiene las palabras "IN and OUT" ("pENTgO y FUERr3'g sabre las conexiones para garantizar Rue el interceptor de 97asa se instate en la direcci6n correcta. EI interceptor de grasa se debe instalar to mas cerca posible de Jos artefactos a los que abastece, Ya que sada pie de la tuberia entre la Fuente de grasa y el interceptor no esti protegido y constituye una posible Fuente de acumulaci6n de grass. Se deben evitar las instalaciones para las que sewn necesarios tramos extensos de tuberia (que excedart Eos 25 pies [8 mi) para poder Hegar of interceptor Era precauci6n disminuira la posibilidad de que las tuberias se obstruyan con grasa antes de Ilegar at interceptor de arasa, Las tineas de desechos de grasa deben entubarse con una indinacion minima de 114 pulgada par pie (6 mm por 30Y mm) para mantener el flujo en la Ifnea de desagbe- Wa►ida tlnicamente. cuando la tarjeta de la garantia se Elena y se envr`a de vuelta at fabricante (Pig 24). Flow Control Installation The flow control device furnished with the Endura Grease interceptor is essential to the proper operation of this unit. The flour control limits the unit to its rated capacity allowing enough time for grease separation to take place inside the interceptor. The 'low control fitting is molded in PVC and must be solvent welded using PVC or PVC/ ABS transition cement as appropriate. it is to be located in the drain line beyond the last connection from the fixture and as close as possible to the underside of the lowest fixture, seepage 8-11 for typical installation. When the discharge from two or more sinks or fixtures are combined and served by one interceptor, a single flow control fitting should be used. I he flow control device can be recessed into the floor if required and extension sleeves are available to complete a good finish at final floor level. Example: 3922125C Compact Version Version compacte Version compacta Cleanout • Prise d'air Limpieza Installation du regulateur de debit Le regulateur de debit fourni avec ifntercepteur de graisse Endura est essentiel au hon fonctionnement de Iintercepteur. Le regulateur de debit, limite le debit a la caPadte nominale de }intercepteur afin de donner suffisamment de temps pour la separation de la graisse dans lintercepteur- Le reguiateur de debit de flux est moult,; en PVC et dolt etre soude au soivant avec du ciment de transition PVC ou PVC/ABS, le cas echeant. Le regulateur de debit comporte une fleche qui indique le Sens de recoulement 11 est essential que le regulateur de debit soit installe dans le bon sens, consultez les pages 8-11 pour les Installations typiques. Lorsque deux (ou plus) eviers ou appareils de plomberie sont raccordes au meme tuyau d`evacuation et desservis par le meme intercepteu , un seul reguiateur de debit devrait ztr=utiCise. Le dispositif de contriiie de debit peat etre encastre dans le plancher au besoin. Des manchons d'extension sont disponibles afin d'obtenir une bonne finition sur le plancher. • Flow direction • Sens de I'ecoulement • Identil icador de la direccian del flujo ------------ tnstalacion del disposltivo de Control de thio El dispositiva de control de flujo que se provee junto con el interceptor de grana Endura es fundamental para el correcto funcionamiento de esta unidad. E€ control de ftujo lim ita la unidad a su capacidad estipulada, to cua€ permite tiempo suiciente Para que se leeve a cabo la separacion de grasa dentro del interceptor. la conector de control de fl*este fabricado con PVC estar soldado y debe con solvente mediante C use de un cemento de PVC o de transition entre FVC y ABS. Debe colocarse en la linea de desagile detras de la ultima conexidn del artef'ccro y to man cera posible de la superficie inferior dei artefacto mas baio, consufte las paginas 8- i 1 para ver la instalacion t€pica_ Cuando las descargas de dos o mas fregaderos o artefactas se combinan y son abastecidas porun interceptor, se debe utilizar un unico conector de control de flujo- De ser necesario, el disPositivo de control de flujo Puede ser instalado al ras del piso_ Tambien hay manguitos de extension disponibles Para realizar un acabado de buena calidad al nivel del piso. • Air Intake • Prise d'air • Entrada de sire • Flow control orifice • Orifice de controle de flux • Oriflcio de control de flujo Example:3933125 Nub Version Embout femelle Version femenina -7- Example: 39331255 • spigotVersion Embout male Version de boquilla Example: 3933125 i • Threaded Version Embout filete • Version con Tosca s'p< ` s Options PnPntmmimWn till dWeje imode3 (2 °n)paraereal¢arernantenimiento ------------ ------------ 6 . i . (len=d waste TLyaua-*re Ai; (retake Dep6sito de descaroa Prise d'air con vettf!aci6n Entrada de afire I. i Opciones de Instalado' n The Endura Lo -PRO is installed on the floor. !Make sure you JOCate the grease interceptor in an area that allows for ease of maintenance Placement should allow the cover to be easily removedanifor cleaning. A minimum clearance of only 5 inches is required above the top of the Grease Interceptor to allow removal of the internal baffles for a complete cleanout. i'intercePteur de graisse Lo -PRO peut etre installe sur le plancher. Assurez--nous d installer I Intercepteur dans un endroit qui en fadlitera 1 entretien. L'emplacement de i'intercepteur doit per mettre d'enlever facilement ie couvercle pour le nettoyage, avec un cidgagernenc minimum de 5 ponces au-dessus de ! Intercepteur afire que ['on puisse retirer les chicanes interieures pour un nettoyage comptet El interceptor de grasa Lo -PRO se puede instalar sobre el piso. Aseabrese de colocar el interceptor de grasa en un area que permita un fall mantenimien to. Se necesita un espacio fibre ntinirno S" sabre la parte superior del interceptor de grana para poder retirar las defiectores internos para una limpieza csmspleta. Minimum Cieanince S hauteur de degagement minimum de 5 po Ahura minima de espacio libre 5" Do flat Fjmed3Si(7.6m) ironrtattnskflatia -' lie pas d@passer 7,t m (25 Pii (Pour ane installation de format Poll NosobrPasarlas25Pies (7,Gm)(instdados PDi) Ftovr Control Device • R6gulateur de debit • vented wast Control de fluja Fj -Tuyau a&r - - Deposita de descarga Gre-se ! con ventilacidn Rh • Flow Control Device qU R€gulateurde debit Grease Interceptor -Control defiujo • Intercepteur de orause Interceptor •Sink F vier Fregadero Cleanout required inmost jurisdiaicns Le nettoyage peut etre obligatoire dais certainesjuridictions_ En algunas jurisdicciones se reouiete una bora delimpieza This illustration represents a typical system design commonly found in food preparation facilities. Adhering to the general installation information presented earlier, select a practical layout to meet the demands of the installation. Les illustrations suivantes repr6-sentent un systeme type communement rencontre dans les etablissements de prEparation des aliments. En uti'lisant les informations d installation generales presentees plus haut, choisissez un agencement qui convient a votTe Installation. La siguiente ilustracion represents un diseno tipica para un sistema que se encuentra comtlnmente en las instaiaciones Para Preparaci6n de alimentos. Cumpliendo con la information de instalaci6n general Presentada anteriormente, escoja una distribucibn practica para satisfacer los requisitos de la instalaci6n. Semi Recessed option • Option semi-ercast ee Option de semiempotrado a nterceptor intercepteur de graisse r-Airintake -Sink Interceptordegrasa Prised-,& e civver I Mrada de acre . Fregadero CAUTION ATTENTION! IL!-10 If installed under a sink, make sure Si lintercepteur est instal!e sous there isatleast 15"clearance (21"for I'evie, prevoyez un degagement GPM moue!) to,emovLtnebariles minimum de 15 Pouces aan de for deaning and maintenance. if this Rouvoir retirer les chicanes pour is not practical, semi -recessing the le nettoyage et !entretien. Si ie tank is an option. degagement nest pas sufr`lsant, le reservoir peut etre semi-encas€re. -4- - A4inimum Clearance 15"/ 21" hauteur de deoagement minimum de 15 po /21 po Altura minima de espacio fibre 15-/21. CleanouE 5"/21- Cleanout required in most jurisdiCZions Le nertoyage pent etre ob(ioatoire dans certaines pinclicti.rm En algunas jurMicciones se rAquiere una boca de limpieza PRECAUCION Si se instala debajo de un hegadero, asegtlrese de que haya un espacio fibre de 15" para que pueda retirar Jos deflectores para su limpieza Y mantenimiento. Si esto no es factible, una ahernativa viable es semiemnotmr al ,- c COmposants Componentes 7GPM-10GPM-15GPM 3907A02 7GPIt4 (0.44 LPS / L/s / L/Seg) 2"(51mm)connection/raccorde tent/cenexian 391 OA0210GPM (0.63 LPS flis / L/Seg) 2"(51 mm ) connection/ raccordement / conexi6n 391SA02C 1 SGPM (0.94 LPS / L/s / L/Seg) 2"(S1 mm) connection/ raccordement / conexi6n ITEM Nombre Description / Descripci6n Part No: Mrnero Itiatrnero de la piece 1lVumero tie parts -Latches -Attaches-Pestiilas 2 -Re" foMe d polypropylene cover - Couvercle en polypropylene renforce de tlylan €391DA-2 - Cubierta de polipropiieno reforzado cover gasket - Joint en neoprene- junta de hut, 4 Removable Outlet Baffle -Deflecteurdesortie amoWble 39TQA-5 - Chicanes amovibles (Enchufe) ='39iQA-4 5 -Removable inlet Baffle- Deltecteurdentreeamovibie - Chicanes amovibles (Entrada) =392QA03-3 6-Direciianal Diffuser- DfflirseurdireciionnelD -eflectordifusor g o � 3 14A-3 -One-plecetank-Nservoirenunepiece-Tanquedeunasolapieza 939TQA02-f 20GPiM 392OA02 20GPM 012£ LPS I Lis / Meg) 2" (51mm) connection/ raccordement 1 conexion ITEM Nombre ! D Description eseripciort Part No: irh�srnero Numero de la piece Ntirrtero de parte I -Latches. -attaches - Pesti!!as 4392QA-9 2 Reinforced polypropylene cover - Couvercle en polypropylene renforce de nylon ; 392QA-2 CubierMa de polipropiieno rtforzado 3 - Rubber gasket -Joint en neoprene -Junta de hule 092QA-5 4 -Removable polypropylene baffles - Nunes amovibles en polypropylene flMA43-3 - Deflectores de polipropiieno desmontables 5 `line-piecetank-Reservoirenunepiece Ta -'-- deunasofapieta 4392DA03-i LO -PRL? Grease Interceptor / dntercepteur cue graiss+` / Interceptor cue grasa 3925A02L0 25GPM (1.5 LPS / Us /L/Seg) 2"(S1rnm) connection/ raccordement/ conexion ITE&I Nornbre Description / Descripci©n nitMmero Part No: Nurndro de to piece 1A - Latches (left) - Attaches (gauche) - Pestillos (lado izquierdo) NOmero de parte 2 z3935A-6Lil 19 - Latches [right} -Attaches (draite)- Pestitias (,ado derecho ) 13935A -(Rif 2 Reinforced polypropylene cover - Couvenie en palypropyli°ne renforce de 7;don -Cubiena de pollpropileno reforzado 43935A.-2 3 Rubber gasket-Jointen neoprene -Junta de hula ir343>A-5 4 Removable polypropylene baffles - Chicanes amovibies en polypropylene a3925A02LO-3 - Deflectores de polipropiieno desroontables 5 -Diffuser Baffle -Diffuser Baffle - Diffuser Baffle y3925AQ2LO-4 5 - One-piece tank - Reservoir en One niece- Tanque de una sola pieta -3425A02t 4-i -13- Components for:/ Compo sants poor! Componentes de. Compact PVC Flow Control Device 4 Regulateur de debit en PVC compact (fit a Dispositivo de control de i`lujo compacto de PVC Description / Description 2" 7 GPM (.44 LPS - Us - L/Seg) 2" 10 GPM (.63 LPS - LIS - L/Seg 2" 15 GPM P94 LPs - Us - L/Seg 2"20 GPM (1.26 LPS - Us - Use 2 25GPM(1.6LPS-Us-L/Seo Part No: Numdro de la piece Numero de parte "3922107C #3922110C #3922115C 4 '3922120C x3922135£ Components for. / Composants pour: / Componentes de-- * Flow Control Assembly with Air Intake Tee 4 Regulateur de debit en PVC avec to Wadmission d'air ° Montaje del control de flujo de PVC cors corrector en T para entrada de aire Description / Descri cion P l Part No: Nunidro de la piece Numero de parpt2 Numero tie parte 3"25 GPM (1.6 LPS - Us - USeg) #3933125 3" 35 GPf1i (2.2 LPS - L/s - L/Seg) #3933135 3 50 GPM (3.24 LPS - Us - L/Seg) 1#3933150 4"35 GPM (2.2 LPS -Us-USeg)3334735 B 4"10GPM (3.2 LPS- L/s - USeg) I # 3934150 l' Components for: / Composants pour / Componentes de: • Optional PVC HOW Control Assembly with Air Intake Tee* Regulateur de debit en PVC avec to d'admission d'air optionnel* o Montaje del control de fliiljo de PVC con corrector en T para entrada de aire opcional� Deseriptiors / Descri uon Part No: P Numero de )a piece Nrimero de parte 2" 7 GPM (.44 LPS - Us - USeg) 43922107 2" 10 GPM (.63 LPS - Us - U5eg ) 1 #3922110 t 2" 1S GPM (.94 LPS - Us - USeg) 73922115 2"20 GPM (1.26 LPS - L/s - L/Seg) 43922120 2"25 GPM (1.6 LPS- Us, L/Seg) 43922125 Components for: / Composants pour: / f/ Componentes de: t ° Air Intake Tee ' ' Ti cl'adrnission d'air ° T para entrada de aire Description t Descripcion Numero de to e a- Numero de parpt2 2"AirintakeTee/Ted'admission d'air /Tpara entrada deaire. x39221-2 3"AirintakeTee/Ted'admission d'air/Tpara entrada de aire #39331-2 4" Air Intake Tee /Ti d'admission d'air/Tpara entrada deaire 9202134 �- " Optianal o PVC Flay Controll assembl} with Air lnT he can be pu,'rlrasedseparatelyand installed in place o€thefampactRaw Control device where it Preferred or req _({oor insialta�ian ofthe (law control_ `Un ensemble dere OlUlat ur d PVC de 1 po avec entree dair optionnel peutetre acnete separementet insiaAeau lieu du regulateurde debit compactiorsque ceEa est recommande ou re uis our les installations du reaulateu; de debr�da�s le p)anchec El 10 req 4o re para de contra! de filujo de PVC dec polo con adndsion de are, puede camprarse porseparado a instalarse en lugardel dispositiva de control de flujo compacto, si se (a refrepr si se la reauiere para una instaladon en el suelo del control de flujo p eo Dimensions dank Dimensions reservoir Dimen5'®nea tanque GPM/lbs a- 10/20 15/30 fpo�C CCGC G `o 'J 25/50 LO 25150 a o° - Ces" Doi G4°�°o"°�p8a°�°o°v°C! CoOpUc°a !sp°, opoCCJ'CCc�C .0°Q�pI B 50/100 A ` A 14.5" (368mm) 14.5" (368mm) >� 31.0" (787mm) A � � i 7.5" fC E 8yQ A i (787mm) D (444mm) (4i44mm) e Dimensions reservoir Dimen5'®nea tanque GPM/lbs 7114 10/20 15/30 20140 25/50 LO 25150 35170 50/100 A 14.5" (368mm) 14.5" (368mm) 14.5" (368mm) 23.5" (600mm) 31.0" (787mm) 31.0„ (787mm) 17.5" i 7.5" 17.5" 175" 23.5" (787mm) (787mm) C (444mm) (4i44mm) (444mm) (444mm) (597mm} (5927mm) (5927mm) (597mm) 3.5" (89mm) 3.5" (89mm) 3.5" (89mm) 35" (89mm) 4„ (102mm) 5.0" (127tnm) 5.0" 5.0 D 11.8" 12 8'' 12.8" 12.r {727mm) (127m) E (325mm) (325mm) (3)5mm) (325mm} 078mm) (318mm) (318mm) (470 mm) (414mm) (414mm) (414mm) (414mm) (279mm) (444mm} 23 5" (447-5" (597 m m) -15- Dimensions - Flow Control Device Assembly To ensure your customer receives the best grease interceptor available, it is advised that you write Your specification using the following vrording: Contractor shall install an Endura' Grease interceptor Part t (fill in). A flow control earth a rate of gpm will be installed in accordance to manufacturer's instructions. The unit shall be comprised OF' engineered thermoplastics to withstand temperatures of 220°F (104°C) and a lid with the capability of supporting 440 lbs. (200 Kgs) The unit will be supported by a 10 year manufacturer's extended warranty. Contractor shall provide mechanical connectors to connect the grease interceptor_ The grease interceptor shall be certified to PDi G101 standard, and where locally applicable to ASME 112143/UFC listed. Operations Your purchase of our Endura Grease Interceptor represents a sound investment in the effective Operation of your food service establishment Train your employees so they can contribute to yourgoal of responsible waste management and reduced maintenance cost. Provide training in: Proper function, operation and maintenance of grease interceptors Proper storage, handling and disposal ofwasres Proper separation and storage of materials Proper use and handling of leaning aids Proper housekeeping the benefits of following the code and the Best Management Practices for food sector facilities. Using a piece of clear 3/4" (20 mm) diameter rigid tubing, insert the tubing into the trap until it bottoms out. Place your thumb over the top of the tube, creating a vacuum which will enable you to extract a cross section of the total liquid depth. Definite levels of solids, water and grease will be visible. Note: Do not lift the tube ciear of the surface of the contents as you will lose your sample due to the vacuum being broken. CAUTION Failure to maintain the Grease S Interceptor can result in heavy fines from the local authority having jurisdiction and/or flooding as a result of the system backing up. Cleaning & Maintenance Alt grease interceptors must be cleaned regularly to maintain efficient operation. The frequency of grease removal is dependent upon a variety of factors, the type of food served, the capacity of the grease interceptor and the quantity of grease in the water. Increasing the frequency of cleaning will reduce odor problems associated with grease traps and improve retention efficiency. The maximum depth of solids permitted to accumulate at the bottom of the trap should not exceed 1"(25 mm). The maximum depth of grease allowed to accumulate prior to servicing shall not represent more than 25% of the liquid volumeoftfie grease interceptoror 2 112'(63 mm) on the 1512012S GPM 04/11_26/1.50 titers Der Second - LPS) and 3176 mm) deep on 35/50 GPM (2.2!3.2 LpS)- Dimensions - Pegulateur de debit - PVG Dwv Pour vous assurer que votre client regoit le meilleur intercepteur de graisse qui Solt nous vous conseillons de rediger une specification comrne celle-ci: Uentrepreneur installera un intr?rc€pteur graisse Endu:2 n` . Un regulateur de debit avec un capacite de debit de gal/ min sera instalJe conformement aux instructions du. fabricant. LSntercepteur comprendra des composants thermoplastiques de haute technologie pouvant resister a des temperatures de 220 °F (104 °Q et un coirverde pouvant supporter jusqu'a 440 Ib (No kg)- Cintercepteur sera appuye par une garaniie Prolong, -6e du fabricant de 10 ans. Uentrepreneur fgurnira des raccords mecaniques pour raccorder 1'intercepteur de grafsse. Lintercepteur de graisse Boit etre certifie selon la norme PDI G101, dans les endroits o6 elle est applicable aux ziements de la lisle ASME 112.14.3 et UPC Informations Generales LSntercepteur de graisse Endura que vous venez d'acheter represente un investissement judicieux Pour 1'esploitation de votre etabliissement de services almentaires. Donnez a vos employes une formation appropriee pour quits puissent contribuer a vatre objectif de gestion responsable des dechets. La formation devrait couvrir les sujets suivants: le fonctionnementet 1 entretien des intercepleurs de graisse le stockage, la manuten tion et 11e1imination de dechets la separation et le stockage de matieres l'utilisation et is manutention de produits de nettoyage l entretien les avantages d'adherer au code et aux meilleures pratiques de gestion pour les etablissements de preparation d'aliments. Vous pouvez utiliser un tuyau rigide d'un diametre net de 3/4 po en Iinserant dans le siphon jusqu'au fond. Prez votre pouce sur le haut du tuyau pour creer un vide qui vous permettra d'eytraire une partie de la hauteur totale du liquide. Vous pourrez ainsi voir les niveaux reels des matieres solider, de Peau et de la graisse. Remarque : Rte souievez pas votre tube hors dela surface des contenus:vous pourriezperdre votre echantillon en perdant le vide tree_ Attention Le defaut de faire i'entretien o de l'intercepteur de graisse peut Z-- entratner des amender imoortantes par les autorites et(ou des inondations 5'1 y a refoulement du systeme. Nettoyage et entretien Tous les intercepteurs de graisse doivent etre nettoyes regulierement pour qu'ils restent efficaces. La frequence de nettoyage depend de divers facteurs comme le type d'aliments servis, la capacite de l'intercepteur de graisse et la quantite de graisse dans Peau. Une frequence de nettoyage accrue per met de reduire le probleme dodeur lie aux intercepteurs de graisse at d'ameliorer 1 efficacite de retention. '.'accumulation maximum de soRdes dans (intercepteur ne devrait pas depasser 1 pouce (25mm). La profondeur maximum de graisse -17- Dimensiones: montaje del dispositivo de control de flujo Para garantizar que su cliente recibe ei mejor• interceptor de grana disponible, es aconsejable que escriba sus especifrcaciones usando la siguiente nota: Contractor shall install an Endura" Grease iEJ contratista debe instaiar el interceptor de grasa Endural Pieta N.o (completar) Se instalaM un control de flujo con una frecuencia de gpm segun las inMcciones del fabricante. La unidad Bebe estar compuesta de termoplasticos de ingenieria para resistir temperaturas de 220°F (104`Q y una tapa con is capacidad de resistir 4401b (200 kg). La unidad tends una garantia extendida del fabricante de 10 anos. El contratista debe proporUonar los conectores mecanicos para cones ar el interceptor de )rasa. EI interceptor de grasa debe ser certificado segun la norma PDl G101 y, donde se aplique segun las normal locales, segun la norma A511VIE 112.14.3/UPC. Operaciones Sucompradenuestrointerceptordegrasa Endura° representa una s6lida inversi6n que le permite operar eficazmente con su establecimiento alimentario. Entrene a sus empleados para que puedan contribuir a su objetivo de manejo responsable de los desechos y de reducci6n de costos de mantenimiento. Capacitelos en: Funic namiento, operad6n y mantenimtemo adecuado de los interceptores de grasa Almacenamiemo, manejo y disposition adecuado de los desechos Separaci6n yalmacenamiento adecuado de Jos materiales Utilizaci6n y maneia adecuado de los eiementos de limpieza Administracidn adecuada de los elementos v locales Las ventajas que representa para los establecimientos alimentarios el hecho de curnpGr con las reglamentaciones y con las Mejores pra .icas de manejo. Tambien puede usar tomo un segmento de tubo rigida transparente de 3/4" (20 mm) de diimetro, fntroduciendoio en la ttampa hasta que il=_gue ai Tondo. Coloque su dedo pulgar sobre is parte superior del tubs Para crear un vaci6 slue le permiti obtener una medici6n de la profundidad total de liquido. Podra ver Jos nineles definitivos de s6lidos, aqua y grana. Nota: No levante e) tubo Por endma del borde del contenida o perdera la muestra cuardo se rompa el vacfo. Cuidado EI hecho de no hacer el mantenimiento e del interceptor de grana puede ocasionar muttas considerables impuestas por las autoridades con jurisdicci6n. a causar inundaciones tomo corse-enda del estancamienta del sistema. Limisieza y mantenimliento Todos los interceptores de grasa deben ser Iimpiaclos con regularidad para que operen eficientemente en todo momento. La frecuencia de la extraccidn de las granas depende de diversos factores: el tipo de alimento que se sir ve en e) establecimiento, la capacidad del interceptor de grasa y la cantidad de grana en el aqua. l.impiezas mas 7- Do not pour coffee grounds or tea leaves down the drain. 8. Recycling. Develop and implement a Plan to reduce, reuse and recycle waste materials. Use a recycling service for your used cocking oil. Used cooking oil can be recycled into useful products such as soap, animal feed and biodiesel products. Separate out food waste ibr delivery to a centralized composting site. 9. Cleaning metal of kitchen exhaust systems. Grease that builds up on exhaust hoods, filters, ducts and fans is usually removed and cleaned to the bare metal by a cerci ed service comparry_ The following cleaning procedure is recommended: Use hand scrapers to remove as much grease as possible from the exhaust System, Collect and store the grease in a separate container labeled " waste grease" Wash the exhaust system with a caustic cleaning solution, collecting the water in a bucket. Neutralize the wash water in the bucket by adding a weak acid such as lemon juice, citric acid or a little vinegar. Skim off any grease Boating in the bucket and store it in the tvaste-grease container. Pour the neutralized vdater from the bucket into a drain that is connected to a grease interceptor. Be careful not to pour the solids at the bottom of the bucket into the drain. Store the solids in the vdaste-grease container. Greater Vancouver Regional District (CVRD), -Best Management Practices & Code Practices for Waste Water Management at (rood Sector Establishments, Nov. 2001, pp 8, 10. "'Vote: Republishing of this information does not infer an endorsement by the CVRD. 5. PlaCez une crepine dans les drains d�vier Pour capter les solider, de rneme que dans le drain de lave-vaisselle pour capter fes particules comme le riz et le mays. 6- Recommandation: Installez un intercepteur de solides special en amont de lintercePteur de graisse pour capter les solides. Les solides prennent de la Place et nuisent - )a separation des huiles et des graisses. De plus, les dechets solides d`aliments pourrissent et finissent par degager des odeurs desagreables- 7. Ne jetez pas de marc de Cafe ou de feuilles de th6 dans le drain. Recydage- Mettez en place un programme de roduction, de reutitisation et de recydage de rebuts. mites appel a un service de recyciage pour votre hufle de cuisson qui peut e r recyciee en produits utiles comme du savon, des aliments pour animaux et du biodiesel- Separez les dechets ahmentaires pour qu'ils Solent ensuite amenes dans un site de compostaoe. 9. Nettoyage des systemes d`evacuation des fumees de la cuisine. La graisse qui s`accumule sur les hottes d'evacuatiion, les Sures, les conduits et fes ventilateurs est habituellement enlevee par une entreprise de service SPeciafisee- La procedure de nettoyage suivante est recommandee Utilisez des grattoirs manuals pour enlever autant de graisse que possible du systeme d`evacuation des fumees- Mettez [a craisse dans un contenant identifie a graisse usee 8. Lavez le sysieme c1l6vwuation avec une solution de nettoyaae caustique et recueillez Peau dans un Beau. Neutralisez 1`eau de lavage dans le seau en y ajoutant un acide faible comme du jus de citron, de Pacide citrique ou un peu de vinaigre. rcumez la graisse dui flotte dans le Beau et placez la graisse dans le contenant a graisse usee. Versez 1`eau neutralisee du seau dans un drain qui est retie a lintercepteur de graisse. Evitez de iaisser les solides dans le fond du Beau se deverser dans le drain. Placez les solides dans ie contenant a graisse usee. "Greater Vancouver Regional District (GVRD), 03est Management Practices & Code Practices for Waste Water Management and Food Sector Establishmenro,, novembre 2001, p.8 10. *Note - La reproduction de tette information ne constitue pas un endossement de la part du CVRD. -19- I Vacie las bandejas, ollas y eiros elementos de cocina can restos de grasa en un contenedor de desechas y grasas antes de ponerlos en un fregadero o un lavavajillas. 4. Deseche los residuos de comida de las ollas, sartenes y platos en un basurzro antes de ponerlos en un fregadero. 5. Ponga un filtro o colado: de testa fino en el tubo del fregadero para atajar las substantias solidas e igualmente en la Salida del lavavajillas para retener los elementos sdlidos Como arroz, maiz y otros. o. Reconwndatiorr. Instate un intercepter especial de sdlidos al comienzo del interceptor de grasas para reterer las Particulas solidas. Los sofidos ocupan espacio y dificultan Ia separation de los aceites y grasas. Ademas, los residuos alimenticios sdlidos que se reunen en un interceptor de grasas se descomponen y Crean problemas de mal olor. 7. No vacie granos de cafe ni hojas de teen las tuberias. 8. Recidado. clabore y ponga en marcha un plan de reduction, reutiiizacidn y reciclaje de los materiales de desecho. Recurra a los servicios de una empresa de recidado para el aceite de Cocer usado. Este aceite puede ser reciclado para €abricar productos utiles tales Comojabon, alimentos para animal=s y productos de biodiesel. Separe los desechos de los al-imentos para hacerios Ilegar a un sitlo de compostacion. 9. Limpieza dei metal de los sistemas de evacuacidn y exhaustacion dela codna. La grana que se acumula en las campanas de evacuation de humps, n`.ltros, conductos y ventiladorrs, generalmente es extra ida y limpiada Por companias de limpieza autorizadas. Se recomienda el siguiente Procedimiento para la limpieza: • Use raspadores manuales para quitar la mayor cantidad de grasa posible del sistema de evacuation. Haaajunta, -y almacenar la grasa en un contenedor separado etiquetado"desechos grasosos° Lave el sistema de evacuation con una solution caustica de limpieza y recolecte el aqua en un balde o cubeta. Neutralice el aqua del lavado de la cubeta anadiendo un acido debit tal COME) iugo de limon, acido c(trico o un Poco de vinagre. Quite toda la grasa que note en is cubeta yalmacenela en el contenedorde grasa de desecho. Vade el aqua neutralizada del balde en un desague que este conectado un interceptor de granas. Asegurese de no vaciar los elementos sdlidos del rondo de la cubeta en el desague. Almacene los sdlidos en el contenedor de desechos grasosos. Greater Vancouver Regional District (GVRD), "Best Management Practices & Code Practices for 141aste lWater Management at Food Sector Establishmente(Mejores practicas recomendadas de manejo de las aguas residuales), noviembre de 2001, pp. B. 10, °Nota: La reaublicacibn Esta informac[on no debe considerarse Como un respaldo del Distrito Regional del Gran Vancouver (CVRD). WE The Endura Grease Interceptor is inspected for manufacturing defects, however, it is not always Possible to detect hidden defects. The Endura Grease Interceptor is warranted only to the extent that the manufacturer will replace without charge products proven to have manufacturing defects within tv elVe (12) months of the date of delivery thereof and provided Seller has been given an opportunity to inspect the product alleged to be defective and the installation and use thereof NO WARRANTY IS INCLUDED AGAINST ANY EXPENSE FOR REMOVAL, REINSTALLATION OR OTHER CONSEQUENTIAL DAMAGES ARISING FROM ANY DEFECT THE WARRANTIES SET OUT ABOVE ARE THE ONLY WARRANTIES MADE BY SELLER AND ARE EYPRESSLYIN LIEU OF ALL OTHER, WARRANTIES, EXPRESSED OR IMPLIED INCLUDING THE WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE. ENDURAO Grease J The Endura' Grease Interceptor is warranted for ten 00) years from the date of installation based on the receipt of a completed v+arrantycard (included with the grease interceptor)_ Said warranty card must be returned to the manufacturer within thirty (30) days of the installation date, in order to be eligible -for this extended warranty, The ten (10) year warranty covers defects resulting from faulty manufacture of materials as well as perforation of the grease interceptor based on normal operating conditions. The manufacturer does not provide a warranty for perforation resulting from mechanical or chemical causes of abnormal use. The Endura' Grease Interceptor is warranted only to the extent that the manufacturer will replace, without charge, products proven to have manufacturing defects or perforation (other tharr Perforation resulting from mechanical or chemical causes) within the specified ten (10) year warranty period and Provided tate manufacturer has been given an opportunity to inspect the product alleged to be defective and the installation and use thereof. No warranty is provided for any expense for removal, reinstallation or other consequential damages arising from and defect or perforation. The uvarrarties setoutaboveare the onlywarranties made by the manufacturer and are expressly in lieu of all other warranties, expressed or implied, including the warranties of merchantability and fitness for a particular purpose Please Note: This warranty is offered by Canplas industries Ltd_ No claim should be placed upon the Installer or Service Company if properly installed and serviced. Garantie Lintercepteur de graisse Endura' a ete inspecte Pour tout defaut de fabrication.11 n est toutefois pas toujours possible de detecter fes defaruts caches. En vertu de tette garantie, ie fabricant remplacera sans frais un produit defectueux dans les dauze ( 12) mois suivant sa date de livraison, pourvu que )e vendeur ait pu inspecter le produit ainsi que son installation etson utilisation_ IL N'Y A AUCUNE GARA,N i fE POUR LES FRAIS DE DEPOSE Ou DE REINSTALLATION, OU POUR TOUT DOMMAGE INCIDENT DECOULANT D -UN DEFAUT LA GARANTIE CI-DESSUS EST LA SEULE GARANTIE FAI T E PAR LEVENDEUR ETSUPPL EE EXPRESSEMENT TOUTEAUTRE GARANTIE EXPRESSE OU iMPuCrrE,Y COMPRIS LES GARAN TIES DEQUALI-EAdARCHANDE OU DAP -1 ITUDE A UN EMPLOI PARTiCULIER_ Garan ie proionge-e de dix (i o) ans pour I intercepteur de graisse ENDURAMD Lintercepteur de graisse Endura") est garanti pour dix (10) ans a compter de sa date d7nstallation selon la carte de garantie incluse avecl intercepteur de graisse. Cette carte de garantie doit €tre remphe et reroumee au fabricant dans les trente (30) jours suivant la date d installation pourque I intercepteur snit couvert par la garantie Prolongee. La garantie de dix (10) ans couvre tout defaut resultant d'un vice de fabrication de materiaux ainsi que la Perforation de lintercepteur sit est utilise en conditions normales. Le fabricant noffre pas de garantie contre les perforations resultant de causes mecaniques ou chimiques ou d'un usage anormal. intercepteur de graisse Endura- est garanti seuiecnent dans la mesure oir iE abricant remPlacera sans frais les produits defecrueux ou ayant subi des perforations (autres que deg Perforations resultant de causes mecanfques ou chimiques) durant la periode de garantie de dix (10) ans et pourvu que le fabricant ait pu inspecter le produit allegU6 defectueux, ainsi que son installation et son utriisation_ it n`y a aucune garantie pour les frais de depose ou de reinstaffation, ou pour tout dommage incident decoulant d'un defaut ou dune perforation. Les garanties ci-dessus sont les seules garanties faites par ie fabricant et suppl¢ent expressernent toute autre garantie -Presse ou implicite, y compris les garanties de qualite marchande ou d'aptitude i un emploi particuiier_ Note: Cette garantie est offerte par Canplas Industries Ltd_ Aucune r6clamation ne devrait etre. faite a I installateur ou a IFntreprise de service , Lintercepteur a ete- bien installe et entretenu. -23- EI interceptor de grasa Endura° ha lido inspeccionado para detectar defectos de fabrication, Pero no siempre es posible detectar defectos ocuttos. El interceptor de grasa Endura, 1►eva garantia consistente solamente en el remPlazo por el fabricante sin cargo de los productos de los que se demuestre que tienen defectos de fabrication dentro de los (12) mews se su fecha de entrega y siempre que a1 Vendedor se le haya dado la oportunidad de inspeccionar el producto del que se dice que es defectuoso y de verificar su fnstalac6n y uso. NO SE iNCLUYE NINGUNA GARANTIA CONTRA NINGUN GASTO DE RFMOCON, REINSfALACION U OiRO DANO CONSECUENCIAL DERIVADO DE ALGON DEEECTO. LAS GARANTIAS MENCiONADAS SON LAS i)NICAS OTORGADAS POR EL VENDEDOR Y SE OTORGAN EXPRESAMENTE EN LUGAR DE TODA OTRA GARANTIA, EXPRESA 0 1r1MPLiCITA, INCLUYENDO LAS GARANTIAS DE COMERCIABILiDAD Y ADECLIACI6N PARA UN FIN ESPEC(FICO 7 - s #. de 10 anos f.i interceptor de grasa Endure E1 interceptor de grasa Endura' Beta Una garantia de diet (10) anos a Partir de la fecha de instalad6n, determinada segtin el recibo de una tarjeta de garantia rellenada (incfuida can el interceptor de grana)_ Para tener derecho a la garantia, dicha tarjeta de garantia debera ser devuefta al fabricarte dentro de los treinta (30) dial de to fecha de instalaci6n. La garantia de (10) ahos cubre los defectos Producidos por defectos de fabricacibn de los materiales, tales coma la Perforad6n del interceptor de grana bajo condiciones normales de operaci6n. EI fabricante no Proporciona garantia Par perforation resultante de causas mecanicas o quimicas debidas a utilizaci6n anormal. La garantia de? interceptor de grasa Endura" consiste sofamente en at reemplazo por el fabricant sin costo, de los productos que se denruestre que tienen defectos de fabricacfon o perforaci6n [que no sea una pert`oraci6n debida a causas mec3nicas o quimicas), dentro del periodo especificado de diez (l0) anos y siempre que se haya dado oPoriunidad al abricante de inspeccionar el producto del que se dice que es defectuoso y su instalaci6n y utilizacion. No se otorga garantia por ningun gasto de mmoci6n, reinstaiaci6n u otro datio consecuenciai derivado de un defecto o perforaci6n. Las garantias expresadasantes son las tinicas garantias otorgadas por el fabricante y reemplazan toda otra garantia, expresa o implicita, incluyendo las garantias de comerciabflidad y de adecuaci6n para un fin en a particular. imPortante_ Esta garantia es otorgada por Canplas industries Ltd. No deberan presentarse reclamaciones at Instalador o la Compacifa encargada del servicic si of sistema ha lido insialado adecuadamente y sf se le ha dado servicio adecuado. NTERSTATE INDUSTRIES INCORPORATE GEI7ERAI Ct 'Nl RAr-TORS-IiOODS=IIVJ%'C "R MIGERATIOTi-IGAS-"HI ATING-COO 1NG WWW.INTERSSATEINDUSTRIESIM C'Q Correction"Letter for ManitaSunsaet Refer to correction letter sent on 6-17-2016 from 8iii Rambo 6128/2016 1. There are no isometric or plumbing plan diagrams provided at any time as requested. Sheet P-2 now includes an isometric plumbing plan. Sheet P-1 has also been further modified to more clearly show plumbing fixtures and relevant equipment information. 2. Plan view drawings are not clear showing all layout of the supply and waste where there are lines all over the plan and difficult to distinguish and identify or are not clearly marked. It was also requested theses diagrams shall be on separate plans. One for supply, one for DWV. Each fixture and any devices shall be clearly specified in the plumbing diagrams. Sheet P-1 has been modified to include more information and to clearly mark plumbing equipment (pipe sizes, lengths, reducers, etc). Sheet P-2 is now the isometric plumbing and has been included for added clarity regarding the plumbing system's location and connection methods. The double check valve assembly product specifications on sheet P-5 has also been updated for clarity and legibility. 3. Sizing calculations and the specific grease interceptor clearly were not specified. A brochure was provided, however sizing calculations and the specific interceptor was not specified. The grease interceptor was existing in the unit. Sizing calculations and specifications for equipment that we do not install should not be required by our company. 4. A gas piping is now added to the plans. New gas piping shall specify lengths of the pipes with the different sizes and shall have a calculation table or similar showing sizing gas piping is sized to meet the demand of all fixtures, new and existing. Lengths and sizes of gas piping have now been added to sheets P-6 and P-7. Additionally, Sheet P-7 now includes a "Gas Appliance Schedule" detailing each connected appliance as well as their relative gas consumption. S. The engineer's stamp again is outdated or expired as of June 13, 2016. Provide new plans that have wet stamp and wet signature of the engineer with expiration date updated. Stamp shall be original size, not enlarged. The engineer's stamp was never outdated or expired. The "June 13, 2016" date that this letter is referring to (and what is written on the stamp) is the date that the stamp was signed not the date that it expires. CORRECTION LTR#—_ RECEIVED CITY OF TUKWILA JUN 28 2016 Gr CA'Allor 124 PERMIT CENTER COMMERCIAL---RESIDENTIAL---LICENSED---BONDED---INSURED---206-387-2364 City of Tukwila Allan Ekberg, Mayor Department of Community Development Jack Pace, Director June 17, 2016 TERRY FLETCHER 1217 4TH AVE N KENT, WA 98031 RE: Correction Letter # 4 PLUMBING/GAS PIPING Permit Application Number PG16-0012 MANILA SUNSET - 307 TUKWILA PKWY Dear TERRY FLETCHER, This letter is to inform you of corrections that must be addressed before your development permit can be approved. All correction requests from each department must be addressed at the same time and reflected on your drawings. I have enclosed comments from the following departments: BUILDING DEPARTMENT: Allen Johannessen at 206-433-7163 if you have questions regarding these comments. (GENERAL NOTE) PLAN SUBMITTALS: (Min. size 11x17 to maximum size of 2406; all sheets shall be the same size. New revised plan sheets shall be the same size sheets as those previously submitted.) (If applicable) "STAMP AND SIGNATURES" "Every page of a plan set must contain the seal/stamp, signature of the licensee(s) who prepared or who had direct supervision over the preparation of the work, and date of signature. Specifications that are prepared by or under the direct supervision of a licensee shall contain the seal/stamp, signature of the licensee and the date of signature. If the "specifications" prepared by a licensee are a portion of a bound specification document that contains specifications other than that of an engineering or land surveying nature, the licensee need only seal/stamp that portion or portions of the documents for which the licensee is responsible." It shall not be required to have each page of "specifications" (calculations) to be stamped and signed; Front page only will be sufficient. (WAC 196-23-010 & 196-23-020) (BUILDING REVIEW NOTES) There still are items that were not provided as requested or are not corrected. Example" 1. There are no isometric or plumbing plan diagrams provided at any time as requested. 2. Plan view drawings are not clear showing all layout of the supply and waste where there are lines all over the plan and difficult to distinguish and identify or are not clearly marked. It was also requested these diagrams shall be on separate plans. One for supply, one for DWV. Each fixture and any devices shall be clearly specified on the plumbing diagrams. 3. Sizing calculations and the specific grease interceptor clearly were not specified. A brochure was provided, however sizing calculations and the specific interceptor was not specified. 4. A gas piping is now added to the plans. New gas piping shall specify lengths of the pipes with the different sizes and shall have a calculation table or similar showing sizing gas piping is sized to meet the demand of all fixtures, new and existing. 5. The engineers stamp again is outdated or expired as of June 13 2016. Provide new plans that have wet stamp and wet signature of the engineer with expiration date updated. Stamp shall be original size, not enlarged. Please provide "all" information as requested. Below is the last memo for your review. **1. There is still other items not addressed from the previous correction memo. Item #2, #4 and #5 shall be provided as requested. Also the new plan submitted has an improper engineers stamp and is not provided with the original signature from the engineer producing those drawings. Please provide plumbing plans as requested to be drawn per plumbing code and architectural plumbing design standards. 6300 Southcenter Boulevard Suite #100 • Tukwila Washington 98188 • Phone 206-431-3670 • Fax 206-431-3665 ** 2. Plumbing plans shall have a separate plan view and isometric plan drawings of all plumbing installations. Plumbing plans shall have separate floor plan layout for drain waste and potable water supply. Plans shall also have a separate gas piping plan to include sizing of the gas pipe and calculations provided for the pipe sizing for the combined gas fixtures served and showing all gas valves. Include approximate length of pipes. Please provide isometric and plan view of all plumbing on the plans. Identify all fixtures served. Show pipe sizes of all pipes (drain waste, water supply and gas). ** 4. Plumbing plans shall be neatly drawn to clearly show the different pipes and fixtures served. Identify point of connections for all plumbing pipes. Specify on the plan two independent check valves, backflow preventer for Carbonated Beverage Dispensers and show where they are located. (2012 UPC Table 603.2) ** 5. Engineers Stamp appears to be outdated or expired. Please provide updated stamp. Please address the comments above in an itemized format with applicable revised plans, specifications, and/or other documentation. The City requires that two 2 sets of revised plan pages, specifications and/or other documentation be resubmitted with the appropriate revision block. In order to better expedite your resubmittal, a'Revision Submittal Sheet' must accompany every resubmittal. I have enclosed one for your convenience. Corrections/revisions must be made in person and will not be accepted through the mail or by a messenger service. If you have any questions, I can be reached at 206-431-3655. Sincerely, 10—bW I Bill Rambo Permit Technician File No. PG16-0012 6300 Southcenter Boulevard Suite #100 • Tukwila Washington 98188 • Phone 206-431-3670 • Fax 206-431-3665 City of Tukwila Allan Ekberg, Mayor Department of Community Development Jack Pace, Director June 03, 2016 TERRY FLETCHER 12174TH AVE N KENT, WA 98031 RE: Correction Letter # 3 PLUMBING/GAS PIPING Permit Application Number PG 16-0012 MANILA SUNSET - 307 TUKWILA PKWY Dear TERRY FLETCHER, This letter is to inform you of corrections that must be addressed before your development permit can be approved. All correction requests from each department must be addressed at the same time and reflected on your drawings. I have enclosed comments from the following departments: BUILDING DEPARTMENT: Allen Johannessen at 206-433-7163 if you have questions regarding these comments. • (GENERAL NOTE) PLAN SUBMITTALS: (Min. size 11x17 to maximum size of 2406; all sheets shall be the same size. New revised plan sheets shall be the same size sheets as those previously submitted.) (If applicable) "STAMP AND SIGNATURES" "Every page of a plan set must contain the seal/stamp, signature of the licensee(s) who prepared or who had direct supervision over the preparation of the work, and date of signature. Specifications that are prepared by or under the direct supervision of a licensee shall contain the seal/stamp, signature of the licensee and the date of signature. If the "specifications" prepared by a licensee are a portion of a bound specification document that contains specifications other than that of an engineering or land surveying nature, the licensee need only seal/stamp that portion or portions of the documents for which the licensee is responsible." It shall not be required to have each page of "specifications" (calculations) to be stamped and signed; Front page only will be sufficient. (WAC 196-23-010 & 196-23-020) (BUILDING REVIEW NOTES) 1. There are still other items not addressed from the previous correction memo. Item #2, #4 and #5 shall be provided as requested. Also the new plan submitted has an improper engineers stamp and is not provided with the original signature from the engineer producing those drawings. Please provide plumbing plans as requested to be drawn per plumbing code and architectural plumbing design standards. ** 2. Plumbing plans shall have a separate plan view and isometric plan drawings of all plumbing installations. Plumbing plans shall have separate floor plan layout for drain waste and potable water supply. Plans shall also have a separate gas piping plan to include sizing of the gas pipe and calculations provided for the pipe sizing for the combined gas fixtures served and showing all gas valves. Include approximate length of pipes. Please provide isometric and plan view of all plumbing on the plans. Identify all fixtures served. Show pipe sizes of all pipes (drain waste, water supply and gas). ** 4. Plumbing plans shall be neatly drawn to clearly show the different pipes and fixtures served. Identify point of connections for all plumbing pipes. Specify on the plan two independent check valves, backflow preventer for Carbonated Beverage Dispensers and show where they are located. (2012 UPC Table 603.2) ** 5. Engineers Stamp appears to be outdated or expired. Please provide updated stamp. 6. Complete and return the enclosed King County Non -Residential Sewer Use Certification form. List only the new fixtures, do not include ones that are being "replaced in kind". 6300 Southcenter Boulevard Suite #100 • Tukwila Washington 98188 • Phone 206-431-3670 • Fax 206-431-3665 Please address the comments above in an itemized format with applicable revised plans, specifications, and/or other documentation. The City requires that two 2 sets of revised plan pages, specifications and/or other documentation be resubmitted with the appropriate revision block. In order to better expedite your resubmittal, a 'Revision Submittal Sheet' must accompany every resubmittal. I have enclosed one for your convenience. Corrections/revisions must be made in person and will not be accepted through the mail or by a messenger service. If you have any questions, I can be reached at 206-431-3655. Sincerely, Bill Rambo Permit Technician File No. PG16-0012 6300 Southcenter Boulevard Suite #100 • Tukwila Washington 98188 • Phone 206-431-3670 • Fax 206-431-3665 City of Tukwila Allan Ekberg, Mayor Department of Community Development Jack Pace, Director May 06, 2016 TERRY FLETCHER 1217 4TH AVE N KENT, WA 98031 RE: Correction Letter # 2 PLUMBING/GAS PIPING Permit Application Number PG 16-0012 MANILA SUNSET - 307 TUKWILA PKWY Dear TERRY FLETCHER, This letter is to inform you of corrections that must be addressed before your development permit can be approved. All correction requests from each department must be addressed at the same time and reflected on your drawings. I have enclosed comments from the following departments: BUILDING DEPARTMENT: Allen Johannessen at 206-433-7163 if you have questions regarding these comments. • (GENERAL NOTE) PLAN SUBMITTALS: (Min. size 11x17 to maximum size of 2406; all sheets shall be the same size. New revised plan sheets shall be the same size sheets as those previously submitted.) (If applicable) "STAMP AND SIGNATURES" "Every page of a plan set must contain the seal/stamp, signature of the licensee(s) who prepared or who had direct supervision over the preparation of the work, and date of signature. Specifications that are prepared by or under the direct supervision of a licensee shall contain the seal/stamp, signature of the licensee and the date of signature. If the "specifications" prepared by a licensee are a portion of a bound specification document that contains specifications other than that of an engineering or land surveying nature, the licensee need only seal/stamp that portion or portions of the documents for which the licensee is responsible." It shall not be required to have each page of "specifications" (calculations) to be stamped and signed; Front page only will be sufficient. (WAC 196-23-010 & 196-23-020) (BUILDING REVIEW NOTES) 1. Previously the information and sizing for the grease interceptor was requested. Please provide the manufacturer's specifications showing the size of grease interceptor with fixture unit calculations for the size of grease interceptor proposed. 2. Plumbing plans shall have a separate plan view and isometric plan drawings of all plumbing installations. Plumbing plans shall have separate floor plan layout for drain waste and potable water supply. Plans shall also have a separate gas piping plan to include sizing of the gas pipe and calculations provided for the pipe sizing for the combined gas fixtures served and showing all gas valves. Include approximate length of pipes. Please provide isometric and plan view of all plumbing on the plans. Identify all fixtures served. Show pipe sizes of all pipes (drain waste, water supply and gas). 3. Change plumbing code shall reference 2012 Uniform Plumbing Code (UPC). 4. Plumbing plans shall be neatly drawn to clearly show the different pipes and fixtures served. Identify point of connections for all plumbing pipes. Specify on the plan two independent check valves, backflow preventer for Carbonated Beverage Dispensers and show where they are located. (2012 UPC Table 603.2) 5. Engineers Stamp appears to be outdated or expired. Please provide updated stamp. 6300 Southcenter Boulevard Suite #100 • Tukwila Washington 98188 • Phone 206-431-3670 • Fax 206-431-3665 PW DEPARTMENT: Joanna Spencer at 206-431-2440 if you have questions regarding these comments. • 1) Please submit grease interceptor specification cut sheets and provide plumbing diagram showing how it will be installed. Please address the comments above in an itemized format with applicable revised plans, specifications, and/or other documentation. The City requires that two 2 sets of revised plan pages, specifications and/or other documentation be resubmitted with the appropriate revision block. In order to better expedite your resubmittal, a'Revision Submittal Sheet' must accompany every resubmittal. I have enclosed one for your convenience. Corrections/revisions must be made in person and will not be accepted through the mail or by a messenger service. If you have any questions, I can be reached at 206-431-3655. Sincerely, Bill Rambo Permit Technician File No. PG16-0012 6300 Southcenter Boulevard Suite #100 • Tukwila Washington 98188 • Phone 206-431-3670 • Fax 206-431-3665 City of Tukwila Department of Community Development February 17, 2016 TERRY FLETCHER 12174TH AVE N KENT, WA 98031 RE: Correction Letter # I PLUMBING/GAS PIPING Permit Application Number PG16-0012 MANILA SUNSET - 307 TUKWILA PKWY Dear TERRY FLETCHER, Allan Ekberg, Mayor Jack Pace, Director This letter is to inform you of corrections that must be addressed before your development permit can be approved. All correction requests from each department must be addressed at the same time and reflected on your drawings. I have enclosed comments from the following departments: BUILDING - PG DEPARTMENT: Allen Johannessen at 206-433-7163 if you have questions regarding these comments. (GENERAL NOTE) PLAN SUBMITTALS: (Min. size 11x17 to maximum size of 2406; all sheets shall be the same size. New revised plan sheets shall be the same size sheets as those previously submitted.) (If applicable) "STAMP AND SIGNATURES" "Every page of a plan set must contain the seal/stamp, signature of the licensee(s) who prepared or who had direct supervision over the preparation of the work, and date of signature. Specifications that are prepared by or under the direct supervision of a licensee shall contain the seal/stamp, signature of the licensee and the date of signature. If the "specifications" prepared by a licensee are a portion of a bound specification document that contains specifications other than that of an engineering or land surveying nature, the licensee need only seal/stamp that portion or portions of the documents for which the licensee is responsible." It shall not be required to have each page of "specifications" (calculations) to be stamped and signed; Front page only will be sufficient. (WAC 196-23-010 & 196-23-020) (BUILDING REVIEW NOTES) 1. Plans provided are not legible. Fonts are blurred where it is not possible to determine which fixtures are provided in the table. I see clouds on the plans but no specific information or explanation. Provide plans with clarity. Clearly cloud and make notes specifying each new fixture that are replacing old ones. If the plan is created by an architect please refer to General Note above "Stamp and Signatures". PW - PG DEPARTMENT: Joanna Spencer at 206-431-2440 if you have questions regarding these comments. • 1) Submit a more legible copy of the plans; Equipment Schedule table is impossible to read. 2) Sheet P-02 shows a grease trap. Please specify on plan size/manufacturer and model number for this trap and submit trap cut sheet/specifications. Please address the comments above in an itemized format with applicable revised plans, specifications, and/or other documentation. The City requires that two 2 sets of revised plan pages, specifications and/or other documentation be resubmitted with the appropriate revision block. In order to better expedite your resubmittal, a 'Revision Submittal Sheet' must accompany every resubmittal. I have enclosed one for your convenience. Corrections/revisions must be made in person and will not be accepted through the mail or by a messenger service. 6300 Southcenter Boulevard Suite #100 • Tukwila Washington 98188 • Phone 206-431-3670 • Fax 206-431-3665 If you have any questions, I can be reached at (206)431-3655. Sincerely, Bill Rambo Permit Technician File No. PG 16-0012 6300 Southcenter Boulevard Suite #100 • Tukwila Washington 98188 • Phone 206-431-3670 • Fax 206-431-3665 PERMIT COORD COPY, PLAN REVIEW/ROUTING SLIP PERMIT NUMBER: PG16-0012 DATE: 06/28/16 PROJECT NAME: MANILA SUNSET SITE ADDRESS: 307 TUKWILA PKWY Original Plan Submittal Revision # before Permit Issued X Response to Correction Letter # 4 Revision # after Permit Issued DEPARTMENTS: 17 U.3 . f� Bui ing qis�jon Fire Prevention ❑ Planning Division ❑ Public Works ❑ Structural ❑ Permit Coordinator PRELIMINARY REVIEW: DATE: 06/30/16 Not Applicable ❑ Structural Review Required ❑ (no approval/review required) REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: DUE DATE: 07/28/16 Approved ❑ Approved with Conditions ❑rJ Corrections Required ❑ (corrections entered in Reviews) Notation: REVIEWER'S INITIALS: Denied ❑ (ie: Zoning Issues) DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: 12/18/2013 PERMIT COORD COPY PLAN REVIEW/ROUTING SLIP PERMIT NUMBER: PG16-0012 DATE: 06/13/16 PROJECT NAME: MANILA SUNSET SITE ADDRESS: 307 TUKWILA PKWY Original Plan Submittal X Response to Correction Letter # 3 Revision # Revision # before Permit Issued after Permit Issued DEPARTMENTS: r' p- CoY�r 2 � ���`� Y Building Division Fire Prevention F-1Planning Division F-1 Public Works ❑ Structural ❑ Permit Coordinator PRELIMINARY REVIEW: DATE: 06/14/16 Not Applicable ❑ Structural Review Required ❑ (no approval/review required) REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: DUE DATE: 07/12/16 Approved ❑ Approved with Conditions ❑ Corrections Required � Denied F1(corrections entered in Reviews) (ie: Zoning Issues) Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: we_ Departments issued corrections: Bldg Fire ❑ Ping ❑ PW ❑ Staff Initials: 12/18/2013 PERMIT COORD COPY PLAN REVIEW/ROUTING SLIP PERMIT NUMBER: PG16-00612 DATE: 05/25/16 PROJECT NAME: MANILA SUNSET SITE ADDRESS: 307 TUKWILA PKWY Original Plan Submittal Revision # before Permit Issued X Response to Correction Letter # 2 Revision # after Permit Issued DEPARTMENTS: 0 tout( 6.14 • 10 Building Division JJS AwL � b Public Works PRELIMINARY REVIEW: Not Applicable ❑ (no approval review required) REVIEWER'S INITIALS: APPROVALS OR CORRECTIONS: Approved ❑ Corrections Required (corrections entered in Reviews) Notation: REVIEWER'S INITIALS: Fire Prevention ❑ Structural ❑ Planning Division ❑ Permit Coordinator ❑ DATE: 05/26/16 Structural Review Required ❑ DATE: DUE DATE: 06/23/16 Approved with Conditions ❑ Denied ❑ (ie: Zoning Issues) DATE: Permit Center Use Only CORRECTION LETTER MAILED: (e �C Departments issued corrections: Bldg r�- Fire ❑ Ping ❑ PW ❑ Staff Initials: —U4 12/18/2013 PERMIT COOK® COPY PLAN REVIEW/ROUTING SLIP PERMIT NUMBER: PG16-0012 DATE: 05/02/16 PROJECT NAME: MANILA SUNSET SITE ADDRESS: 307 TUKWILA PKWY Original Plan Submittal X Response to Correction Letter # 1 DEPARTMENTS: AT (0 fir Building Division j�S Coir, , Public Works PRELIMINARY REVIEW: Not Applicable ❑ (no approval/review required) REVIEWER'S INITIALS: APPROVALS OR CORRECTIONS: Approved ❑ Corrections Required �-- (corrections entered in Reviews) REVIEWER'S INITIALS: Revision # before Permit Issued Revision # after Permit Issued Fire Prevention ❑ Planning Division ❑ Structural ❑ Permit Coordinator 01 DATE: 05/03/16 Structural Review Required ❑ DATE: DUE DATE: Approved with Conditions ❑ Denied ❑ (ie: Zoning Issues) DATE: 05/31/16 Permit Center Use Only C� I CORRECTION LETTER MAILED: Departments issued corrections: Bldg Fire ❑ Ping ❑ PW Staff Initials: V4 12/18/2013 PERMIT COORD COPY PLAN REVIEW/ROUTING SLIP PERMIT NUMBER: PG16-0012 DATE: 02/08/16 PROJECT NAME: MANILA SUNSET SITE ADDRESS: 301 TUKWILA PKWY X Original Plan Submittal Revision # before Permit Issued Response to Correction Letter # Revision # after Permit Issued DEPARTMENTS: /r Cm,fr-jz P -:-i Building Division IN Fire Prevention ❑ Planning Division ❑ �J Cow'\- 1-`tHy Public Works ® Structural ❑ Permit Coordinator ❑ PRELIMINARY REVIEW: DATE: 02/09/16 Not Applicable ❑ Structural Review Required ❑ (no approval/review required) REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: DUE DATE: 03/08/16 Approved ❑ Approved with Conditions ❑ Corrections Required Denied ❑ (corrections entered in Reviews) (ie: Zoning Issues) REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg Fire ❑ Ping ❑ PWW- 12/18/2013 Staff Initials: 12/ 1 R/2013 REVISIO City of TukwilaSUBMITT z Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Web site: hq:Uww�A,.TukwilaWA.gov Revision submittals must be submitted in person at the Permit Center. Revisions will not be accepted through the mail, fax, etc. Date: Plan Check/Permit Number:�� �p ❑ Response to Incomplete Letter # Response to Correction Letter # Revision # after Permit is Issued Revision requested by a City Building Inspector or Plans Examiner ❑ Deferred Submittal # Project Name: M� rj I (,—A- Project Address: LLZ ` � , �v ) `( �% �x t Contact Person:���i����,� Phone Number: t�o, 1 4 Summary of Revision: TJ�9� l 9 RECEIVED CITY OF TUKWtLA- JUN 282016 Sheet Number(s): f "Cloud" or highlight all areas of revision including date of on Received at the City of Tukwila Permit Center by: N—Entered in TRAKiT on � �/'V_ W:\Permit Center\Templates\Forms\Revisum Submittal Form.doc RevisedAugust 2015 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila Washington 98188 Phone: 206-431-3670 Web site: hqp://www.Tukwi]aWA.gov REVISION SUBIVHTTAL Revision submittals must be submitted in person at the Permit Center. Revisions will not be accepted through the mail, fax, etc. Date: C, . l - l ("=, Plan Check/Permit Number: 'y C l .0— 0®o, ❑ Response to Incomplete Letter # Response to Correction Letter # ❑ Revision # after Permit is Issued ❑ Revision requested by a City Building Inspector or Plans Examiner ❑ Deferred Submittal # Project Name: Parka Project Address:` Qit� Contact Person: r�_ h. wl .qk�'\`Phone Number: Summary of Revision: RECEIVED CITY OF TUKWILA-, JUN 13 2015 Sheet Number(s): "Cloud" or highlight all areas of revision including date of revision c Received at the City of Tukwila Permit Center by: _�ry Entered in TRAKiT on lD—1 S— W:\Pemtit CenteATemplates\FormARevision Submittal Fmm.doe Revised: August 2015 V City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Fax: 206-431-3665 Web site: http://www.ci.tukwila.wa.us REVISION SUBMITTAL Revision submittals must be submitted in Person at the Permit Center. Revisions will not be accepted through the mail, fax, etc. Date: 5- Is --z C', Plan ChecWPermit Number: PG 16-0012 ❑ Response to Incomplete Letter # ® Response to Correction Letter # 2 ❑ Revision # after Permit is Issued ❑ Revision requested by a City Building Inspector or Plans Exatniner Project Name: Manila Sunset Project Address: 307 Tukwila Pkwy RECEIVES. CITY OF TUfCWIL MAY 2 5 2016 PERMIT CENTER Contact Person: P.A L&t— Phone Number: 1�2 — L'IiA f- �\ ! SL Summary of Revision: Sheet Number(s): "Cloud" or highlight all areas of revision including date of revision Received at the City of Tukwila Permit Center by: AXL ❑ Entered in TRAKT on \applications\forms-applications on line\revision submittal Created: 8-13-2004 Revised: City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Web site: http://wwA,.TukwilaNVA.gov REVISION SUBMITTAL Revision submittals must be submitted in person at the Permit Center. Revisions will not be accepted through the mail, fax, etc. Date:_ 'S ^ Plan Check/Permit Number: '�h ❑ Response to Incomplete Letter # LF Response to Correction Letter # ❑ Revision # after Permit is Issued ❑ Revision requested by a City Building Inspector or Plans Examiner ❑ Deferred Submittal # Project Name: �C\\\C' _ 'S'w \' Project Address: Akt-k., C, Contact Person: of 'Sk-t—�R— Phone Number: Summary of Revision: rP 0-a.� Galk RECEIVE'D CITY OF TUKWILA MAY a Z 2016 Sheet Number(s): 3 cW "Cloud" or highlight all areas of revision Mcludmg date of r ision Received at the City of Tukwila Permit Center by: --7%4 'Entered in TRAKiT on WAPernut Center\Templates\Forms\Revision Submittal Form. doe Revised: August 2015 Interstate Industries INC Home Espanol Contact Safety & Health Washington State Department of Labor 1& Industries Interstate Industries INC Page 1 of 3 Search L&I A -'L Index help My L&I Claims & Insurance Workplace Rights Trades & Licensing Owner or tradesperson 12235 SE 199th ST 603 286 240 KENT, WA 98031 Principals 206-387-2364 Smith, Lorne Joseph, PRESIDENT KING County Doing business as 03/23/2016 Interstate Industries INC Expiration date WA UBI No. Business type 603 286 240 Corporation License Verify the contractor's active registration / license / certification (depending on trade) and any past violations. Construction Contractor ........................._................................................ Active. 03/23/2016 Meets current requirements. Expiration date License specialties GENERAL License no. INTERII873137 Effective — expiration 03/27/2013— 03/27/2017 Bond ................. Western Surety Co $12,000.00 Bond account no. 62298394 Received by L&I Effective date 02/23/2015 02/11/2015 Expiration date Until Canceled Bond history Insurance Preferred Contractors Ins Co R $1,000,000.00 Policy no. PC99758-02 Received by L&I Effective date 03/30/2016 03/23/2016 Expiration date 03/23/2017 Insurance history Savings Nonsavings accounts during the previous 6 year period. Lawsuits against the bond or savings Cause no. 15-2-01375-1SEA OPen Complaint filed by Complaint against bond(s) or savings TRUETEMP NORTHWEST INC 41309861 https:Hsecure.lni.wa.gov/verifyIDetail.aspx?UBI=603286240&LIC=INTERII873D7&SAW= 7/7/2016 SCOPE OF WORK 1. FIELD INSTALL NEW ABOVEGROUND PEX PIPING. EXISTING PLUMBING EXISTED IN THE PREVIOUS RESTAURANT, THE NEW KITCHEN DESIGN, THE UNDERGROUND PLUMBING WILL REMAIN, REUSE EXISTING GREASE TRAP. REUSE EXISTING PEX PIPE, INSTALL NEW COMPRESSION VALVES AT NEW SINKS, WITH NEW HOSES & CONNECTIONS, 1/2 WAY THROUGH THE CONSTRUCTION PHASE THE OWNER ADDED NEW ADA RESTROOM INSTALL ALL PIPING IN ACCORDANCE WITH INTERNATIONAL BUILDING CODE 2012, INTERNATIONAL MECHANICAL CODE 2012) UNIFORM PLUMBING CODE 2012 AND OTHER APPLICABLE CODES/STANDARDS. 2. EXISTING EQUIPMENT IS SHOWN FOR CLARITY. IT IS NOT PART OF THE PROJECT SCOPE. GENERAL NOTES 1. DRAWINGS REFLECT EXISTING CONDITIONS. CONTRACTOR TO FIELD INSTALL NEW ABOVEGROUND PEX PIPING TO SUPPLY HOT AND COLD WATER TO NEW RESTROOM. DOUBLE CHECK VALVE — (SEE PRODUCT SPECS ON SHEET P-4) ON DEMAND H,W.H � �if T41 SINK & PLUMBING SCHEDULE 171 PREP SINK 171 PREP SINK 179 HAND SINK 172 3 COMP SINK 196 GREASE TRAP (EXISTING) 209 DISH WASHER 175 MOP SINK 299 HOT WATER HEATER 199 EXITING FLOOR DRAIN 201 NEW SINK AND NEW TOILET 179 HAND SINK 194 POT FILLER FAUCET A PIPELINE REDUCER NEW 1/2 WATER LINE FOR POT FILLER NEW 3/4 LINE FOR RESTROOM NEW ADA RESTROOM PIPELINE REDUCER EXISTING 80 GALLON H,W,T TO BE REMOVED AND REPLACED WITH (2) GAS—FIRED, ON DEMAND WATER HEATERS, REWORK PLUMBING IN THIS AREA TO ACCOMMODATE NEW TANKS AND DOUBLE CHECK VALVE, EXISTING C❑LD—LINE TO EXISTING HOT—WATER EXISTING GREASE TRAP REMAIN, REUSE, LINE TO REMAIN, REUSE, 0 0 A A PIPELINE REDUCER PIPELINE REDUCER PIPELINE REDUCER PIPELINE REDUCER R 3/4" 24 54 ro 0 ' ZI 20 24 � I, , i � � 17 30 30 _ 160 W LK- 3/4" C O,OLE I I I I 5 36 II/ CN ELEC PANE 3" on M O � Z MZ ;;uM H z --i Mo 101 (3/4" N < M Z a Z7 0 To I W461- aia ■��.. I................t■ 4� rnHOMME.eou■ - �i.....�..r...u..... , • J � Cs i R� V N ``ter, Fo.a 1 1111111 ��,'' II ASSEMBLY T LINE _I '7 lir 30x 36 1 3' M ------------------ 167 � 1six 120(166 199 199 �------------ fi5fi----------- 0 101 112 ,--� mmmmnnmmmmmmmmmn .r.. ._ �� ---- 30x (o 1 R _ o 113 0 --- -- -®-- - -- - - 106 �-- -- 163 193 --I -- -- 103 -- -fi `IPEREE) -- GLASS S i C1O F:E EC — — ----------- i F1 C,41 'i 218 218 1 1 I I 219 19� 219 n ' 2�1 i -------------------� ru < r 217 217 217 21 Interstate Group, Inc, Interstate Fire, Inc.. Interstate Ru COPY Industries, Inc. '09014- Interstate Permit Heating Plan review approval is sublsct to errors and omissions. sions. and Cooling' Inc, Approval of construction documents does not Uuz 10111M the violation of any ad ted roda or dinanes. P�eccipt of approved Field C and conditic 's acknowledged: 1217 4th Ave N. Kent, WA 98032 Date: 206-679-3268 - - www.interstateindustries.com City of Tulewila �uLD1� DfVlSI MANILA REVIEWED FOR CODE COMPLIANCE APPROVED JUL O 1 016 I of Tukwila BUIL ING DIVISION REVISIONS No changes Small be made to the scope of work without prior approval of Tu,%-,ila Building Division. �_ } T E: Se'Jisio,rs iiil rquire a new plan submittal and may i, ..udo add tional plan revivr fees SEE /—EXTERIOR ELEVATION i 104 CORR C� TION LTR#. NO CHANGES WILL PE MADE WITHOUT HEALTH DEPARTMENT APPROVAL PUBLIC HEALTH - KING HEALTH DEPARTMENT INSPECTION REQUIRED UPON COMPLETION OF WORK PRIOR TO OPENING SATE PEPMIT RE.,Q,/UIRED FOR. 111 Mechanlcali Rf Electrical ❑ Plumbing ❑ Gas Piping City of Tukwila I301—DING DIVISION RECEIVED CITY OF TUKWILA JUN 28 2016 PERMIT CENTER SUNSET 307 TUKWILA PARKWAY TUKWILA) WA 98188 PLUMBING PLAN 4237 IRONTON DR WEST RICHLAND, WA 99353 509-531-6906 www.TRICITYENGINEERS.com DRAWN: 5/25/2016 KJE REVISED: 6/10/2016 KJE Q REVISED: 6/24/2016 KJE SCOPE OF WORK 1. FIELD INSTALL NEW ABOVEGROUND PEX PIPING. EXISTING PLUMBING EXISTED IN THE PREVIOUS RESTAURANT, THE NEW KITCHEN DESIGN, THE UNDERGROUND PLUMBING WILL REMAIN, REUSE EXISTING GREASE TRAP. REUSE EXISTING PEX PIPE, INSTALL NEW COMPRESSION VALVES AT NEW SINKS, WITH NEW HOSES & CONNECTIONS, 1/2 WAY THROUGH THE CONSTRUCTION PHASE THE OWNER ADDED NEW ADA RESTROOM INSTALL ALL PIPING IN ACCORDANCE WITH INTERNATIONAL BUILDING CODE 2012, INTERNATIONAL MECHANICAL CODE 2012, UNIFORM PLUMBING CODE 2012 AND OTHER APPLICABLE CODES/STANDARDS. 2. EXISTING EQUIPMENT IS SHOWN FOR CLARITY. IT IS NOT PART OF THE PROJECT SCOPE. GENERAL NOTES 1. DRAWINGS REFLECT EXISTING CONDITIONS. CONTRACTOR TO FIELD INSTALL NEW ABOVEGROUND PEX PIPING TO SUPPLY HOT AND COLD WATER TO NEW RESTROOM. PIPELINE REDUCER 1/2" 3/4" 1/2" 3/4" PIPELINE REDUCE 1/2" PIPELINE REDUCER 1/2" I,&-klFS 1/2" C*] \a t 1/2" PIPELINE REDUCE All R V1� p� PAGE 0De ppmpvED SO\ 01 110% CRY Of Tuwmla sin- fit* t)NISION RECEIVED CITY OF TUKWILA JUN 28 2036 PERMIT CENTER NO CHANGES WILL BE MADE WITHOUT HEALTH DEPARTMENT APPROVAL PUBLIC HEALTH - KING HEALTH DEPARTMENT INSPECTION REQUIRED UPON COMPLETION OF WORK PRIOR TO OPENING f=LU 15ING f=L N 150 IETf;;; C J Interstate Group, Inc. Interstate Fire, Inc„ Interstate Industries, Inc, Interstate Heating and Cooling, Inc. 1217 4th Ave N. Kent, WA 98032 206-679-3268 www.interstateindustries.com MANILA SUNSET 307 TUKWILA PARKWAY TUKWILA, WA 98188 PLUMBING PLAN ISOMETRIC ENGINEERS 42371RONTON DR WEST RICHLAND, WA 99353 509-531-6906 www.TRICITYENGINEERS.com DRAWN: 5/25/2016 KJE REVISED: 6/10/2016 KJE REVISED: 6/24/2016 KJEAR SCALE - VARIES SHEET t1�1U tf t43 �k� Atro� iJ 1� ff? 1 ''�i.�x3:v iaacJ3dOMAN% a+ 2OF7 HEALTH DEPT. NOTES 1. AN INDIRECT WASTE DRAIN IS REQUIRED FOR THE FOOD PREPARATION SINK, THREE—COMPARTMENT SINK, MECHANICAL DISHWASHER, ICE MACHINE, POP DISPENSER, RUNNING WATER DIPPER WELL, STEAM TABLE, WALK—IN REFRIGERATION, AND ANY EQUIPMENT IN WHICH FOOD IS PLACED. 2.IF THE ESTABLISHMENT CONTINUES TO BE IN OPERATION DURING THE REMODEL, DUST BARRIERS MUST BE INSTALLED TO ENSURE THAT FOOD PROTECTION AND SAFETY ARE NOT COMPROMISED. THE FOOD SERVICE ESTABLISHMENT WILL BE REQUIRED TO DISCONTINUE OPERATIONS IF ANY DISRUPTION IN WATER, ELECTRICAL, OR SEWER SERVICE OCCURS, DUE TO THE REMODEL. HANDWASH FACILITIES MUST BE KEPT ACCESSIBLE AND FUNCTIONAL DURING ALL HOURS OF FOOD SERVICE ESTABLISHMENT OPERATION. 3.A HORIZONTAL SEPARATION OF AT LEAST 16 INCHES OR A VERTICAL PARTITION OF 16 INCHES IN HEIGHT IS REQUIRED BETWEEN THE FOOD PREPARATION SINK AND ALL OTHER SINKS AND/OR SOURCES OF CONTAMINATION. 4.HOT WATER MUST BE AVAILABLE TO ALL HANDWASH SINKS WITHIN 15 SECONDS. THE HOT WATER FOR THE FACILITY MUST NOT BE USED AT ANY PLUMBING FIXTURE FOR A MINIMUM OF 6 HOURS PRIOR TO THE PREOPERATIONAL INSPECTION. THIS IS REQUIRED SO THAT PROPER TESTING OF THE 15—SECOND TIME REQUIREMENT FOR HOT WATER AVAILABILITY CAN BE COMPLETED. 5.ALL FOOD SERVICE EQUIPMENT, BOTH NEW AND USED, MUST BE LISTED BY THE NATIONAL SANITATION FOUNDATION (NSF) OR EQUIVALENT FOR ITS INTENDED USE. USED AND NEW REFRIGERATION MUST BE CAPABLE OF HOLDING POTENTIALLY HAZARDOUS FOOD AT 417 OR BELOW. 6.USED EQUIPMENT IS SUBJECT TO ONSITE INSPECTION TO DETERMINE ACCEPTABILITY FOR USE IN THE PROPOSED FOOD SERVICE ESTABLISHMENT. USED EQUIPMENT MUST BE CLEAN, IN PROPER OPERATING CONDITION, AND IN GOOD REPAIR. USED REFRIGERATION MUST BE CAPABLE OF HOLDING POTENTIALLY HAZARDOUS FOODS AT A TEMPERATURE OF 417 OR BELOW 7.EXTRA WALL PROTECTION IS REQUIRED ON WALLS BEHIND ALL SINKS, INCLUDING RESTROOM HANDWASH SINKS, AND FOOD PREPARATION COUNTERS AND TABLES. A 16—INCH HIGH BACKSPLASH OF PLASTIC LAMINATE, FIBERGLASS—REINFORCED PLASTIC OR EQUAL IS ACCEPTABLE. A BACKSPLASH HIGHER THAN 16 INCHES IS REQUIRED ON THE WALL BEHIND COUNTER TOP EQUIPMENT TALLER THAN 16 INCHES. FLOOR TO CEILING PROTECTION IS REQUIRED ON THE WALL BEHIND DISHWASHERS. WALL PROTECTION BEHIND MOP SINKS MUST COVER THE ENTIRE SPLASH ZONE. PLASTIC COATED HARDBOARD IS NOT ACCEPTABLE. 8.ALL FLOORS IN THE KITCHEN, FOOD PREPARATION, FOOD SERVICE, FOOD STORAGE, AND DISHWASHING AREAS MUST BE SURFACED WITH A DURABLE, NONABSORBENT, EASILY CLEANABLE MATERIAL. EXPANSION JOINTS, SEAMS, SAW CUTS AND THE LIKE IN CONCRETE FLOORS IN ALL AREAS, INCLUDING CUSTOMER SEATING AREAS, MUST BE FILLED AND SEALED SO AS TO PROVIDE A SMOOTH AND CLEANABLE SURFACE. 9.THE CEILING ABOVE THE FOOD PREPARATION AREAS MUST BE NONPERFORATED, NONABSORBENT, SMOOTH AND EASILY CLEANABLE. 10. ALL LIGHT FIXTURES IN FOOD PREPARATION AND STORAGE AREAS MUST BE PROVIDED WITH COVERS OR SHATTERPROOF BULBS. 1 1. PLUMBING MUST MEET STATE AND LOCAL CODES. 12. THE VENTILATION SYSTEM SHALL BE INSTALLED AND OPERATED TO MEET APPLICABLE BUILDING, MECHANICAL AND FIRE CODES. 1A.4iFS EQUIPMENT & ITEMS PROVIDED BY OWNER/TENNANT AND INSTALLED BY GENERAL CONTRACTOR. TY I No. DESCRIPTION MANUFACTURER & MODEL 1 101 FIRE EXTINGUISHER K SERIES PROVIDED BY GC INSTALLED BY GC 1 102 FIRE EXTINGUISHER 2AIOB:C PROVIDED BY GC INSTALLED BY GC 11103 MENU BOARD PROVIDED BY TENANT INSTALLED BY GC 1104 EXTERIOR SIGNAGE Salisbury Lockers Ten—Tier Plastic PROVIDED BY TENANT INSTALLED BY GC 1105 EMPLOYEE'S LOCKER MESA SAFE MLF3020EE PROVIDED BY TENANT INSTALLED BY GC 1006 SAFE PROVIDED BY TENANT INSTALLED BY GC 1 107 PROVIDED BY TENANT INSTALLED BY GC 1 108 POS PROVIDED BY TENANT INSTALLED BY GC 1 112 4' ORDER COUNTER PROVIDED BY TENANT INSTALLED BY GC 1 113 TELEPHONE SYSTEM PANASONIC KT—TG9478 PROVIDED BY TENANT INSTALLED BY GC 1 114 DEGREASER D—CARBONATOR 40 GAL PROVIDED BY TENANT INSTALLED BY GC 1 115 SELF SERVE BEVERAGE DISPENSER W ICE BIN AT TOP Coca Cola PROVIDED BY TENANT INSTALLED BY GC 1117 COFFEE MAKER Bunn VP17-2 SS (NOT SHOWN) PROVIDED BY TENANT INSTALLED BY TENA 1122 Food Processor (NOT SHOWN) Waring WFP14SW PROVIDED BY TENANT INSTALLED BY TENANI 1123 STOCK POT WARMER TURBO AIR TASP-18 PROVIDED BY TENANT INSTALLED BY GC 1124 BUN RACK CHANNEL 620 FRONT LOADING PROVIDED BY TENANT INSTALLED BY GC 1 126 Rice Warmer (NOT SHOWN) TOWN RM-55N—R 55 PROVIDED BY TENANT INSTALLED BY GC 1 133 ICE MAKER HOSHIZAKI F-330BAH—C PROVIDED BY TENANT INSTALLED BY TENANI 2 134 Microwave Oven SHARP R21 LCF PROVIDED BY TENANT INSTALLED BY GC 2 140 Exhaust Hood Captive Air PROVIDED BY GC INSTALLED BY GC 1 149 Conveyor Oven Lincoln Impinger 1 1 16000U PROVIDED BY TENANT INSTALLED BY GC 1 150 Range 24 TURBO AIR TAR -4 24 PROVIDED BY TENANT INSTALLED BY GC 1 151 Radiant Charbroiler — 48" WITH STAND STAR 6148RCBF PROVIDED BY TENANT INSTALLED BY GC 1 153 24X36 TABLE PROVIDED BY TENANT INSTALLED BY GC 1 154 Fryer, Gas FRYMASTER GF40 SD GAS FRYER PROVIDED BY TENANT INSTALLED BY GC 1 160 Walk—in Refrigeration/Freezer Box and Compressor 70X7OX56 Masterbilt PROVIDED BY TENANT INSTALLED BY GC 1 163 Refrigerated Counter, Sandwich Top TRUE TSSU-60-16 PROVIDED BY TENANT INSTALLED BY GC 1 164 Refrigrated, Work Top True TWT -36 PROVIDED BY TENANT INSTALLED BY GC 1 165 Ice Cream Freezer True TFM-29FL WHT PROVIDED BY TENANT INSTALLED BY GC 1 166 Ice Cream Dipper Well Grindmaster FW -510 dipper well & faucet PROVIDED BY TENANT INSTALLED BY GC 1 167 Ice Shaver Hatsuyuki HC 8E - DIRECT CIRCUIT REQ PROVIDED BY TENANT INSTALLED BY GC 1 169 Work Table -30" x60" ADVANCE TABCO SLAG -305 PROVIDED BY TENANT INSTALLED BY GC 1 170 Hot Food Table VOLLRATH 38105 SERVEPAN ELECTRIC FIVE PAN PROVIDED BY TENANT INSTALLED BY GC 2 171 PREP SINK ADVANCE TABCO KM SLAG-303//KMS-11B-305L WITH FAUCET PROVIDED BY TENANT INSTALLED BY GC 3—COMP RIGHT HAND SINK & FAUCET W HANDLES ELKAY 3C18X24-L-18X STANDARD SINK PROVIDED BY TENANT INSTALLED BY GC 1 173 FRE RINSE UNIT T&S B-0133-01 PRE -RINSE PROVIDED BY TENANT INSTALLED BY GC 1 174 CLEAN RIGHT HAND DISH TABLE CMA CR -36 PROVIDED BY TENANT INSTALLED BY GC 1 175 Mop Sink 24 x 24 x 10 Mustee 63M PROVIDED BY TENANT INSTALLED BY GC 2 178 TANKLESS ELECTRIC WATER HEATER NORITZ NC 250 PROVIDED BY GC INSTALLED BY GC 2 179 Hand Sink KROWNE HS -26L PROVIDED BY TENANT INSTALLED BY GC 4 180 Wall Shelves NOT SHOWN ADVANCE TABCO WS -15-96 PROVIDED BY TENANT INSTALLED BY GC 2 181 Wall Shelf for Microwave Advance Tabco MS -18-24 PROVIDED BY TENANT INSTALLED BY GC 2 182 '-Wall Wall Shelves NOT SHOWN ( ) ADVANCE TABCO WS -15-84 PROVIDED BY TENANT INSTALLED BY GC 1 183 Shelves NOT SHOWN ADVANCE TABCO WS -15-144 PROVIDED BY TENANT INSTALLED BY GC 1 184 Wall Shelves NOT SHOWN JOHN BOOS BHS1863—TS PROVIDED BY TENANT INSTALLED BY GC 1 193 Work Table -30" x 36" ADVANCE TABCO KM SLAG -303 PROVIDED BY GC INSTALLED BY GC 2 194 POT FILLER FAUCET T&S B-0594 POT FILLER FAUCET PROVIDED BY TENANT INSTALLED BY GC 1 196 GREASE INTERCEPTOR PROVIDED BY TENANT INSTALLED BY GC PROVIDED BY GC INSTALLED BY GC 1 198 SPLASH GUARD PROVIDED BY TENANT INSTALLED BY GC 3 199 FLOOR DRAIN YTENANT 1 200 CHEF BASE REFRIGERATION _ PROVIDED BY TENANT INSTALLED BY GC 1 201 CUSTOM CABINET DESIGN PER TENANT PROVIDED BY TENANT INSTALLED BY GC 2 202 SHELVING 18X48X72 PROVIDED BY TENANT INSTALLED BY GC 1 203 SHELVING 18X6OX72 PROVIDED BY TENANT INSTALLED BY GC 2 204 SHELVING 24X48X72 PROVIDED BY TENANT INSTALLED BY GC 1 205 SHELVING 24X54X72 PROVIDED BY TENANT INSTALLED BY GC 2 206 SHELVING 3OX54X72 PROVIDED BY TENANT INSTALLED BY GC 1 207 SHELVING 24X36X72 PROVIDED BY TENANT INSTALLED BY GC 1 208 SHELVING 24X48X36 PROVIDED BY TENANT INSTALLED BY GC 1 209 Chemical IS waS er Ecolab INFERNO - w/ VAPPR VENT or sim PROVIDED BY TENANT INSTALLED BY GC 1 210 SHELVING 18X36X72 PROVIDED BY TENANT INSTALLED BY GC 1 213 SOUND SYSTEM ( OPTIONAL: GC TO COORDINATE WIRING AND LOCATION WITH TENANT) PROVIDED BY TENANT INSTALLED BY GC 1 214 PREP REFRIGERATOR True TSSU-27-8-1 PROVIDED BY TENANT INSTALLED BY GC 1 215 2 DOOR REACH IN REFRIGERATOR True T-49PROVIDED BY TENANT INSTALLED BY GC 1 216 " y in" PROVIDED BY TENANT INSTALLED BY GC 4 217 300THS 63"W X 43" L SEAT 4 MILLENNIUM OAK SLAT WALL STYLE BOOTH PROVIDED BY TENANT INSTALLED BY GC 2 218 PICNIC TABLE 38 W X 74 L 3 219 PICNIC BENCHES PROVIDED BY TENANT INSTALLED BY GC 11 220 WAITING BENCH PROVIDED BY TENANT INSTALLED BY GC 1221 148" PICNIC BENCHES ALL FOOD MUST BE STORED 6" FROM FLOOR RECEIV;= CITY OF TUKWIL.A JUN 2 8 2016 RERPOI`I" CENTER } Interstate Group, Inc. Interstate Eire, Inc„ Interstate Industries, Inc. Interstate Heating and Cooing, Inc. 1217 4th Ave N. Kent, WA 98032 206-679-3268 www.interstateindustries.com MANILA SUNSET 307 TUK\DILA PARKWAY TUKWILA) WA 98188 EQUIPMENT LIST TRI -CITY ENGINEERS 4237 IRONTON DR WEST RICHLAND, WA 99353 509-531-6906 www.TRICITYENGINEERS.com DRAWN: 5/25/2016 KJE REVISED: 6/10/2016 KJE REVISED: 6/24/2016 KJE SCALE - VARIES SHEET Sl)SRkYif`t!'!�. 3OF7 SCOPE OF WORK 1. FIELD INSTALL NEW ABOVEGROUND PEX PIPING. EXISTING PLUMBING EXISTED IN THE PREVIOUS RESTAURANT, THE NEW KITCHEN DESIGN, THE UNDERGROUND PLUMBING WILL REMAIN, REUSE EXISTING GREASE TRAP. REUSE EXISTING PEX PIPE, INSTALL NEW COMPRESSION VALVES AT NEW SINKS, WITH NEW HOSES & CONNECTIONS, 1/2 WAY THROUGH THE CONSTRUCTION PHASE THE OWNER ADDED NEW ADA RESTROOM INSTALL ALL PIPING IN ACCORDANCE WITH INTERNATIONAL BUILDING CODE 2012, INTERNATIONAL MECHANICAL CODE 2012, UNIFORM PLUMBING CODE 2012 AND OTHER APPLICABLE CODES/STANDARDS. 2. EXISTING EQUIPMENT IS SHOWN FOR CLARITY. IT IS NOT PART OF THE PROJECT SCOPE. GENERAL NOTES 1. DRAWINGS REFLECT EXISTING CONDITIONS. CONTRACTOR FIELD INSTALL NEW ABOVEGROUND PEX PIPING TO SUPPLY HOT AND COLD WATER TO NEW RESTROOM. SINK & PLUMBING SCHEDULE 171 PREP SINK 171 PREP SINK 179 HAND SINK 172 3 COMP SINK 196 GREASE TRAP (EXISTING) 209 DISH WASHER 175 MOP SINK 299 HOT WATER HEATER 199 EXITING FLOOR DRAIN 201 NEW SINK AND NEW TOILET 179 HAND SINK 194 POT FILLER FAUCET NEW ADA RESTROOM ELEG PANE 0n MO £z Mz �r-9 n F- -� H z� m a FAI 40"X40" CENTER 5EE /-EXTERIOR ELEVATION NO CHANGES WILL BE MADE WITHOUT HEALTH DEPARTMENT AFFROVAL PUBLIC HEALTH - KING HEALTH DEPARTMENT INSPECTION REQUIRED UPON COMFLETION OF WORK PRIOR TO OPENING UJ STE NED VENT -=L N SCALE: 3/S`' _ V_011 R ' �v1E�P� p,NC� cm \\100" RECER(ED CITY OF TUKWILA JUN 28 2016 PERMIT CENTER Interstate Group, Inc, Interstate Eire, Inc., Interstate Industries, Inc. Interstate Heating and Cooling, Inc. 1217 4th Ave N. Kent, WA 98032 206-679-3268 www.interstateindustries.com MANILA SUNSET 307 TUKWILA PARKWAY TUKWILA, WA . .. WASTE AND VENT 1. TRI -CITY ENGINEERS 4237 IRONTON DR WEST RICHLAND, WA 99353 509-531-6906 www.TRICITYENGINEERS.com DRAWN: 5/25/2016 KJE REVISED: 6/10/2016 KJE REVISED: 6/24/2016 KJE SCALE - VARIES SHEET 4OF7 Job Name Contractor Job Lccatlon Approval Englneer Contractor's P.O. No. Approval fieprc:sentatPve Series 007 r s Double Check Valve Assemblies Sizes: 1h1t - 211 Series 007 Double Check Valve Assemblies art, damned to s protest drinkir-g vrater supptles from dari�cmus cross-connec• �ti■ `ItaBttAR tt>,...�.,.■wt�.tra�.rrtt�ltrt;tr�I ��■iiR �!�w 'A liens In accnrrfartt a 411 natiand plumbing codes and water authority "uirttments for non-potaabla service applications 1.007M1QT such as irrigallor, firellne, or industrial procoft. Only these eroso-carneGbone ldentifled by local insipeollo n authorities e3 i non -health hazard shall bo *#owed the use of an approved " double check valve assembly. Chuck vAth local auftitty, haft )trrlscllctlron regarding varttcal now orientation, fmcluency of toasting or oft, irstallotion rt tt ante, � The valve ah all meet the requirements of ASSE Std. 1,015 and AWWA Std, 0610. Approved by the Foundation for Cross - W, Connection Control and iiydrouto Research at the Unlvarwiity ofSou IMtr�sw��rr#wrt#•�_5-. Ttlt"101t��trr�;;�.+t=�sttr� them California. teoif,AtQT•S Features • Em of rnafntenanrxt - only one cover • Top way • Relolacoable seats and seat discs Modular c anstrLvtron • Compact design • Ghat bronze body construction -'A' - 2' Tcp mounted bell valve test cocks • Low pressure drop * No special tarts required for Sarvlcng • W —I I have tee handy Specifications A Double Chock 1lslve Assombfy shall ba installed at each noted location. Trio assembly shall consist of tvio possllve seating check moclules with captured sp V gs and rubber seat c18c8. The check modulo seats and seat discs shad be replaceable. S&Mce of all Internal components shall be through a slrtgte bronze or stainless; tient,/ access cover secured vAth stol s steel belts. The assembly shall dao include two reall- lent anted Isolation vahres; four top moarnted, resient seated test cocks. The assembly sMi meet the requhments of ASSE Std. 1016 acid A WA Std, 0810. Approved by the Foundation for Crom-Corraction Control and Hydrarulio Research at lhts UnNerelty of 8outhsrn Califcrria. Assembly shall be a Watts 8edea 007. drat G: sock s@Bone macro Modula Assembly Module Assembly The 007 t3arias features a madular design concept wNch facltitates complete maintenance and assembly by rets'ning the spring lead. �-Now Avi lli able , ;'i�t'lltt�i�Ct3t �i�tl�lallatt�.EilfyiCt&taraf�a. •I .. • •For mala lnftxrriation,'s�gd fCu llteraitlrit• ES WA.... Inquire, with governing autt-oritle-A for loom installation ractulrornents a'�1erraduti�liau.�rsa6cmayta'btnd rtt��asaapm�sreara�+,Ca�ttuKtc�. rarprccacm�s,ta�ncr� ad pewnfi t! *A WM4 wj ettikco rrt tart h tt tar W kftu on Mtls p Axis fr orstd►tt Nol UK %11WATM to.1,;At. Pressure — Temperature 1/al — 2" Temperature Flange: 3a'F —1 GL'F (Q.8°C — 626C). MaAmum Working Prass=, 175psi (12.1 tom, Standards ASST: Std, 1015, AWWA Std. 0510 lAPMO PS31, CSA B64.6 ag Approvals -5. t ASSE, AWWA, IAPM3, CBA, UFC A Approved by the Foundation for Gross Conneotion Control and t tydaul'io Research at the Univeraily of Southern ca�for T + Models LF and S are not listed. UL Classified (LF models o*) a/4' - 2' (except 007MM • 1-11or3zontal and v©rded "flay up, approval an all sues Dimensions - Weights Models uS• i2ev 1/2' — 2' suffix: 8 • bronze strainer LF - without shuioff varves SH - stalnless steal ball valve handles HO - 21h' Wet/oWet tiro hydrant fittings (2' valva) Prefix: U • Lt,icn connections 'Subscript 181 _ atralner model Suffix tit; -- Fire Hydrant Fittings dlmensfon "A' s 23'A' (594mm) Dimensions - Weights V UC07MOT Unica Tallploco••• Unim Nut ........ ........... .............. ............................. A .......... .._.................. Sizes: t/zn - 21, Unlon Tailpiece Union Nut NO CHANGES WILL 5E MADE WITHOUT HEALTH DEPARTMENT APPROVAL PUBLIC HEALTH - KING HEALTH DEPARTMENT INSPECTION REQUIRED UPON COMPLETION OF WORK PRIOR TO OPENING capacity Ae coy pplfad from documented Foundation for Ctoas-Conrtacum Central and Rydratn#o tlasaarch at the Un1wrolty Of 5outtlorn Wtilorala Eab fasts. yoloelm xiiflomuil system flow rata (7.5 feet/sec., 2.3 meters/se4.) UL rat4od 'h' (tttrtirn) t" sd a 1t Nu.7 iC n i a 4 .1 1 ta+t 0 4 G I,1 eta 7t4 aa4 tib las Flaw it 55 7a 43 fin 1'h" (40mm) till; 0 At7 .7 is s a a a at a a 0 93 A 114 ty >s it{t19 2" (tukrim) Id � u 7 7s ,.s a :, .4 a its 14 .a uz � 0 � km 1a to 'Ira It>� �r+ltttai rr,s>•■ttr�ttr�� '�t>•� t8�tt8aata�ttRB>�� a as s r �ti■ `ItaBttAR tt>,...�.,.■wt�.tra�.rrtt�ltrt;tr�I ��■iiR �!�w 'A t����t>�laat#�!�I t■twt��t>:tt�■rlt�'"..,:/��I, tAttl�lel��� a�•�:.rrttrt•nntattt�rrrea•ttett�ttrett. t���C#t>t�ta�l♦�n» u �■11111�ttaal i t�srte �t tt•�rae�rrrtt>•s rrrra�rwal�n�wtttrt.l now tt•ttttt•t�rttae t�ttt•�attsstaettatUotr�rAn rot IMtr�sw��rr#wrt#•�_5-. Ttlt"101t��trr�;;�.+t=�sttr� it 55 7a 43 fin 1'h" (40mm) till; 0 At7 .7 is s a a a at a a 0 93 A 114 ty >s it{t19 2" (tukrim) Id � u 7 7s ,.s a :, .4 a its 14 .a uz � 0 � km 1a to 'Ira It>� �r+ltttai rr,s>•■ttr�ttr�� '�t>•� t8�tt8aata�ttRB>�� a as s r u ut t�ltrt•rt•rt�tllw�tttt�ttl�ltil�fta>•��t now tt•ttttt•t�rttae t�ttt•�attsstaettatUotr�rAn rot IMtr�sw��rr#wrt#•�_5-. Ttlt"101t��trr�;;�.+t=�sttr� �f�f/■ �����t1i•��� �srwwrr®r��.® aalt��fr��� a� A Werra w97er Tecnn6140103 camparty ES -007 1318 DOUFDLE C EC< V LVE SCALE: N/A ajor :3.. USA: Tal: ge7$i 688.1311 • Fax tM M-1846 + �+r;��t wa la cArrs Canadat Td: Oq 332.4000 Fax: OW 332.7068 + Nw,w wst4.w l� �131'e'Otla t l�� PNCC RECEIVED CITY OF T UKWIL: JUN 28 2016 PERMIT CENTER � 5 } `�� •y �% G Interstate Group, Inc. Interstate Eire, Inc„ Interstate Industries, Inc. Interstate Heating and Cooing, Inc, 1217 4th Ave N. Kent, WA 98032 206-679-3268 www.interstateindustries.com MANILA SUNSET 307 TUKWILA PARKWAY TUKWILA, WA 98188 VALVE ASSEMBLY PRODUCT SPECS TRI -CITY ENGINEERS 4237 IRONTON DR WEST RICHLAND, WA 99353 509-531-6906 www.TRICITYENGINEERS.com DRAWN: 5/25/2016 KJE REVISED: 6/10/2016 KJE REVISED: 6/24/2016 KJE SCALE - VARIES SHEET A Y UvCtttem ,may! �'f,�i kF,$UIX. 1 zta�„sorxs�za 50F7 r �r»>w�r�tatr.r,tt�s�tt�trr.rr.rt� t�ltrt•rt•rt�tllw�tttt�ttl�ltil�fta>•��t tt•ttttt•t�rttae t�ttt•�attsstaettatUotr�rAn tt�ti•rrt•=R IMtr�sw��rr#wrt#•�_5-. Ttlt"101t��trr�;;�.+t=�sttr� �(�11■MI�^ rirrr��twt>ti rtt�rwr•■r���.w A �f�f/■ �����t1i•��� �srwwrr®r��.® aalt��fr��� a� A Werra w97er Tecnn6140103 camparty ES -007 1318 DOUFDLE C EC< V LVE SCALE: N/A ajor :3.. USA: Tal: ge7$i 688.1311 • Fax tM M-1846 + �+r;��t wa la cArrs Canadat Td: Oq 332.4000 Fax: OW 332.7068 + Nw,w wst4.w l� �131'e'Otla t l�� PNCC RECEIVED CITY OF T UKWIL: JUN 28 2016 PERMIT CENTER � 5 } `�� •y �% G Interstate Group, Inc. Interstate Eire, Inc„ Interstate Industries, Inc. Interstate Heating and Cooing, Inc, 1217 4th Ave N. Kent, WA 98032 206-679-3268 www.interstateindustries.com MANILA SUNSET 307 TUKWILA PARKWAY TUKWILA, WA 98188 VALVE ASSEMBLY PRODUCT SPECS TRI -CITY ENGINEERS 4237 IRONTON DR WEST RICHLAND, WA 99353 509-531-6906 www.TRICITYENGINEERS.com DRAWN: 5/25/2016 KJE REVISED: 6/10/2016 KJE REVISED: 6/24/2016 KJE SCALE - VARIES SHEET A Y UvCtttem ,may! �'f,�i kF,$UIX. 1 zta�„sorxs�za 50F7 SCOPE OF WORK 2. FIELD INSTALL NEW ABOVEGROUND PEX PIPING. EXISTING PLUMBING EXISTED IN THE PREVIOUS RESTAIIRANIT TI -IF NEW KITCHEN DESIGN, THE UNDERGROUND I REMAIN, REUSE EXISTING GREASE TRAP. REL PEX PIPE, INSTALL NEW COMPRESSION VALV SINKS, WITH NEW HOSES & CONNECTIONS, THROUGH THE CONSTRUCTION PHASE THE C NEW ADA RESTROOM INSTALL ALL PIPING IN WITH INTERNATIONAL BUILDING CODE 2012) MECHANICAL CODE 2012, UNIFORM PLUMBI 2012 AND OTHER APPLICABLE CODES/STAN[ EXISTING EQUIPMENT IS SHOWN FOR CLARIT' PART OF THE PROJECT SCOPE. GENERAL NOTES 1. DRAWINGS REFLECT W FIELD INSTALL NEW SUPPLY HOT AND EXISTING CONDITIONS. C ABOVEGROUND PEX PIPI COLD WATER TO NEW RE`. A R E SINK 8c PLUMBING SCHEDULE 171 PREP SINK 171 PREP SINK 179 HAND SINK 172 3 COMP SINK 196 GREASE TRAP (EXISTING) 209 DISH WASHER 175 MOP SINK 299 HOT WATER HEATER 199 EXITING FLOOR DRAIN 201 NEW SINK AND NEW TOILET 179 HAND SINK 194 POT FILLER FAUCET -rn r A <- AA r Trfl /-\ THROUGH ROOF T0� APPLIANCES MAKE—UP AIR UNITAR NO CHANCES UJILL 5E MADE UJITHOUT HEALTH DEPARTMENT APPROVAL PU5LIC HEALTH - KING HEALTH DEPARTMENT INSPECTION REQUIRED UPON COMPLETION OF UjORK PRIOR TO OPENING FRO 01= L N SCALE: 3/S" = V -0" 0 oF0 °° �° .<� 01216 G�'� 0 a SSC gV1Lowe RECEIVED CITY OF TUI(WILA JUS! 28 2016 PERMIT CENTER Interstate Group, Inc, Interstate Fire, Inc„ Interstate Industries, Inc. Interstate Heating and Cooling, Inc, 1217 4th Ave N. Kent, WA 98032 206-679-3268 www.interstateindustries.com MANILA SUNSET 307 TUKWILA PARKWAY TUKWILA, WA 98188 ROOF PLAN TRI -CITY ENGINEERS 4237 IRONTON DR WEST RICHLAND, WA 99353 509-531-6906 www.TRICITYENGINEERS.com D RAW N : 5/25/2016 KJ E REVISED: 6/10/2016 KJE REVISED: 6/24/2016 KJE SCALE - VARIES SHEET 6OF7 SCOPE OF WORK 1. FIELD INSTALL NEW ABOVEGROUND PEX PIPING. EXISTING PLUMBING EXISTED IN THE PREVIOUS RESTAURANT, THE NEW KITCHEN DESIGN, THE UNDERGROUND PLUMBING WILL REMAIN, REUSE EXISTING GREASE TRAP. REUSE EXISTING PEX PIPE, INSTALL NEW COMPRESSION VALVES AT NEW SINKS, WITH NEW HOSES & CONNECTIONS, 1/2 WAY THROUGH THE CONSTRUCTION PHASE THE OWNER ADDED NEW ADA RESTROOM INSTALL ALL PIPING IN ACCORDANCE WITH INTERNATIONAL BUILDING CODE 2012, INTERNATIONAL MECHANICAL CODE 2012, UNIFORM PLUMBING CODE 2012 AND OTHER APPLICABLE CODES/STANDARDS. 2. EXISTING EQUIPMENT IS SHOWN FOR CLARITY. IT IS NOT PART OF THE PROJECT SCOPE. GENERAL NOTES 1. DRAWINGS REFLECT EXISTING CONDITIONS. CONTRACTOR TO FIELD INSTALL NEW ABOVEGROUND PEX PIPING TO SUPPLY HOT AND COLD WATER TO NEW RESTROOM. I I GAS SUPPL TO ROOF GAS SUPPL TO ROOF I GAS LINE DETAIL ------ ------ ------ ------ GAS LINE DETAIL SINK 8c PLUMBING SCHEDULE 171 PREP SINK 171 PREP SINK 179 HAND SINK 172 3 COMP SINK 196 GREASE TRAP (EXISTING) 209 DISH WASHER 175 MOP SINK 299 HOT WATER HEATER 199 EXITING FLOOR DRAIN 201 NEW SINK AND NEW TOILET 179 HAND SINK 194 POT FILLER FAUCET 7 A I :a 2 Q GAS APPLIANCE SCHEDULE AR N0. APPLIANCE 123 24" STOCK POT WARMER 149 (2) COMBINATION OVEN 48" 154 36" (2) 151 60" 154 24" STOVE -BURNER FLATTOP ON -DEMAND WATER CHARBROILER FLAT HEATER ELEC PANE GAS CONSUMPTION 200BTU 3013TU/3013TU 150BTU 120BTU 150BTU 250BTU 40"X40" CENTER NO CNAHCsES WILL BE MADE WITHOUT HEALTH DEPARTMENT APPROVAL PUBLIC HEALTH - KING HEALTH DEPARTMENT INSPECTION REQUIRED UPON COMPLETION OF UIORIC PRIOR TO OPENING : = L f= I FING N 5CALE: 3/a" = V-0 > G RECEIVED CITY OF TUKWILA JUIN 2 8 2016 PERMIT CENTER Interstate Group, Inc. Interstate Eire, Inc„ Interstate Industries, Inc, Interstate Heating and Cooing, Inc. 1217 4th Ave N. Kent, WA 98032 206-679-3268 www.interstateindustries.com MANILA SUNSET 307 TUKWILA PARKWAY TUKWILA, WA 98188 GAS PIPING AND DETAILS 1 0 i 4237 IRONTON DR WEST RICHLAND, WA 99353 509-531-6906 www.TRICITYENGINEERS.com DRAWN: 5/25/2016 KJE REVISED: 6/10/2016 KJE REVISED: 6/24/2016 KJE SCALE - VARIES SHEET 7OF7 SCOPE OF WORK 1. FIELD INSTALL NEW ABOVEGROUND PEX PIPING. EXISTING PLUMBING EXISTED IN THE PREVIOUS RESTAURANT, THE NEW KITCHEN DESIGN, THE UNDERGROUND PLUMBING WILL REMAIN, REUSE EXISTING GREASE TRAP. REUSE EXISTING PEX PIPE, INSTALL NEW COMPRESSION VALVES AT NEW SINKS, WITH NEW HOSES & CONNECTIONS, 1/2 WAY THROUGH THE CONSTRUCTION PHASE THE OWNER ADDED NEW ADA RESTROOM INSTALL ALL PIPING IN ACCORDANCE WITH INTERNATIONAL BUILDING CODE 2012, INTERNATIONAL MECHANICAL CODE 2012) UNIFORM PLUMBING CODE 2012 AND OTHER APPLICABLE CODES/STANDARDS. 2. EXISTING EQUIPMENT IS SHOWN FOR CLARITY. IT IS NOT PART OF THE PROJECT SCOPE. GENERAL NOTES 1. DRAWINGS REFLECT EXISTING CONDITIONS. CONTRACTOR TO FIELD INSTALL NEW ABOVEGROUND PEX PIPING TO SUPPLY HOT AND COLD WATER TO NEW RESTROOM. DOUBLE CHECK VALVE — (SEE PRODUCT SPECS ON SHEET P-4) ON DEMAND H,W.H � �if T41 SINK & PLUMBING SCHEDULE 171 PREP SINK 171 PREP SINK 179 HAND SINK 172 3 COMP SINK 196 GREASE TRAP (EXISTING) 209 DISH WASHER 175 MOP SINK 299 HOT WATER HEATER 199 EXITING FLOOR DRAIN 201 NEW SINK AND NEW TOILET 179 HAND SINK 194 POT FILLER FAUCET A PIPELINE REDUCER NEW 1/2 WATER LINE FOR POT FILLER NEW 3/4 LINE FOR RESTROOM NEW ADA RESTROOM PIPELINE REDUCER EXISTING 80 GALLON H,W,T TO BE REMOVED AND REPLACED WITH (2) GAS—FIRED, ON DEMAND WATER HEATERS, REWORK PLUMBING IN THIS AREA TO ACCOMMODATE NEW TANKS AND DOUBLE CHECK VALVE, EXISTING C❑LD—LINE TO EXISTING HOT—WATER EXISTING GREASE TRAP REMAIN, REUSE, LINE TO REMAIN, REUSE, 0 0 A A PIPELINE REDUCER PIPELINE REDUCER PIPELINE REDUCER PIPELINE REDUCER R 3/4" 24 54 ro 0 ' ZI 20 24 � I, , i � � 17 30 30 _ 160 W LK- 3/4" C O,OLE I I I I 5 36 II/ CN ELEC PANE 3" on M O � Z MZ ;;uM H z --i Mo 101 (3/4" N < M Z a Z7 0 To I W461- aia ■��.. I................t■ 4� rnHOMME.eou■ - �i.....�..r...u..... , • J � Cs i R� V N ``ter, Fo.a 1 1111111 ��,'' II ASSEMBLY T LINE _I '7 lir 30x 36 1 3' M ------------------ 167 � 1six 120(166 199 199 �------------ fi5fi----------- 0 101 112 ,--� mmmmnnmmmmmmmmmn .r.. ._ �� ---- 30x (o 1 R _ o 113 0 --- -- -®-- - -- - - 106 �-- -- 163 193 --I -- -- 103 -- -fi `IPEREE) -- GLASS S i C1O F:E EC — — ----------- i F1 C,41 'i 218 218 1 1 I I 219 19� 219 n ' 2�1 i -------------------� ru < r 217 217 217 21 Interstate Group, Inc, Interstate Fire, Inc.. Interstate Ru COPY Industries, Inc. '09014- Interstate Permit Heating Plan review approval is sublsct to errors and omissions. sions. and Cooling' Inc, Approval of construction documents does not Uuz 10111M the violation of any ad ted roda or dinanes. P�eccipt of approved Field C and conditic 's acknowledged: 1217 4th Ave N. Kent, WA 98032 Date: 206-679-3268 - - www.interstateindustries.com City of Tulewila �uLD1� DfVlSI MANILA REVIEWED FOR CODE COMPLIANCE APPROVED JUL O 1 016 I of Tukwila BUIL ING DIVISION REVISIONS No changes Small be made to the scope of work without prior approval of Tu,%-,ila Building Division. �_ } T E: Se'Jisio,rs iiil rquire a new plan submittal and may i, ..udo add tional plan revivr fees SEE /—EXTERIOR ELEVATION i 104 CORR C� TION LTR#. NO CHANGES WILL PE MADE WITHOUT HEALTH DEPARTMENT APPROVAL PUBLIC HEALTH - KING HEALTH DEPARTMENT INSPECTION REQUIRED UPON COMPLETION OF WORK PRIOR TO OPENING SATE PEPMIT RE.,Q,/UIRED FOR. 111 Mechanlcali Rf Electrical ❑ Plumbing ❑ Gas Piping City of Tukwila I301—DING DIVISION RECEIVED CITY OF TUKWILA JUN 28 2016 PERMIT CENTER SUNSET 307 TUKWILA PARKWAY TUKWILA) WA 98188 PLUMBING PLAN 4237 IRONTON DR WEST RICHLAND, WA 99353 509-531-6906 www.TRICITYENGINEERS.com DRAWN: 5/25/2016 KJE REVISED: 6/10/2016 KJE Q REVISED: 6/24/2016 KJE SCOPE OF WORK 1. FIELD INSTALL NEW ABOVEGROUND PEX PIPING. EXISTING PLUMBING EXISTED IN THE PREVIOUS RESTAURANT, THE NEW KITCHEN DESIGN, THE UNDERGROUND PLUMBING WILL REMAIN, REUSE EXISTING GREASE TRAP. REUSE EXISTING PEX PIPE, INSTALL NEW COMPRESSION VALVES AT NEW SINKS, WITH NEW HOSES & CONNECTIONS, 1/2 WAY THROUGH THE CONSTRUCTION PHASE THE OWNER ADDED NEW ADA RESTROOM INSTALL ALL PIPING IN ACCORDANCE WITH INTERNATIONAL BUILDING CODE 2012, INTERNATIONAL MECHANICAL CODE 2012, UNIFORM PLUMBING CODE 2012 AND OTHER APPLICABLE CODES/STANDARDS. 2. EXISTING EQUIPMENT IS SHOWN FOR CLARITY. IT IS NOT PART OF THE PROJECT SCOPE. GENERAL NOTES 1. DRAWINGS REFLECT EXISTING CONDITIONS. CONTRACTOR TO FIELD INSTALL NEW ABOVEGROUND PEX PIPING TO SUPPLY HOT AND COLD WATER TO NEW RESTROOM. PIPELINE REDUCER 1/2" 3/4" 1/2" 3/4" PIPELINE REDUCE 1/2" PIPELINE REDUCER 1/2" I,&-klFS 1/2" C*] \a t 1/2" PIPELINE REDUCE All R V1� p� PAGE 0De ppmpvED SO\ 01 110% CRY Of Tuwmla sin- fit* t)NISION RECEIVED CITY OF TUKWILA JUN 28 2036 PERMIT CENTER NO CHANGES WILL BE MADE WITHOUT HEALTH DEPARTMENT APPROVAL PUBLIC HEALTH - KING HEALTH DEPARTMENT INSPECTION REQUIRED UPON COMPLETION OF WORK PRIOR TO OPENING f=LU 15ING f=L N 150 IETf;;; C J Interstate Group, Inc. Interstate Fire, Inc„ Interstate Industries, Inc, Interstate Heating and Cooling, Inc. 1217 4th Ave N. Kent, WA 98032 206-679-3268 www.interstateindustries.com MANILA SUNSET 307 TUKWILA PARKWAY TUKWILA, WA 98188 PLUMBING PLAN ISOMETRIC ENGINEERS 42371RONTON DR WEST RICHLAND, WA 99353 509-531-6906 www.TRICITYENGINEERS.com DRAWN: 5/25/2016 KJE REVISED: 6/10/2016 KJE REVISED: 6/24/2016 KJEAR SCALE - VARIES SHEET t1�1U tf t43 �k� Atro� iJ 1� ff? 1 ''�i.�x3:v iaacJ3dOMAN% a+ 2OF7 HEALTH DEPT. NOTES 1. AN INDIRECT WASTE DRAIN IS REQUIRED FOR THE FOOD PREPARATION SINK, THREE—COMPARTMENT SINK, MECHANICAL DISHWASHER, ICE MACHINE, POP DISPENSER, RUNNING WATER DIPPER WELL, STEAM TABLE, WALK—IN REFRIGERATION, AND ANY EQUIPMENT IN WHICH FOOD IS PLACED. 2.IF THE ESTABLISHMENT CONTINUES TO BE IN OPERATION DURING THE REMODEL, DUST BARRIERS MUST BE INSTALLED TO ENSURE THAT FOOD PROTECTION AND SAFETY ARE NOT COMPROMISED. THE FOOD SERVICE ESTABLISHMENT WILL BE REQUIRED TO DISCONTINUE OPERATIONS IF ANY DISRUPTION IN WATER, ELECTRICAL, OR SEWER SERVICE OCCURS, DUE TO THE REMODEL. HANDWASH FACILITIES MUST BE KEPT ACCESSIBLE AND FUNCTIONAL DURING ALL HOURS OF FOOD SERVICE ESTABLISHMENT OPERATION. 3.A HORIZONTAL SEPARATION OF AT LEAST 16 INCHES OR A VERTICAL PARTITION OF 16 INCHES IN HEIGHT IS REQUIRED BETWEEN THE FOOD PREPARATION SINK AND ALL OTHER SINKS AND/OR SOURCES OF CONTAMINATION. 4.HOT WATER MUST BE AVAILABLE TO ALL HANDWASH SINKS WITHIN 15 SECONDS. THE HOT WATER FOR THE FACILITY MUST NOT BE USED AT ANY PLUMBING FIXTURE FOR A MINIMUM OF 6 HOURS PRIOR TO THE PREOPERATIONAL INSPECTION. THIS IS REQUIRED SO THAT PROPER TESTING OF THE 15—SECOND TIME REQUIREMENT FOR HOT WATER AVAILABILITY CAN BE COMPLETED. 5.ALL FOOD SERVICE EQUIPMENT, BOTH NEW AND USED, MUST BE LISTED BY THE NATIONAL SANITATION FOUNDATION (NSF) OR EQUIVALENT FOR ITS INTENDED USE. USED AND NEW REFRIGERATION MUST BE CAPABLE OF HOLDING POTENTIALLY HAZARDOUS FOOD AT 417 OR BELOW. 6.USED EQUIPMENT IS SUBJECT TO ONSITE INSPECTION TO DETERMINE ACCEPTABILITY FOR USE IN THE PROPOSED FOOD SERVICE ESTABLISHMENT. USED EQUIPMENT MUST BE CLEAN, IN PROPER OPERATING CONDITION, AND IN GOOD REPAIR. USED REFRIGERATION MUST BE CAPABLE OF HOLDING POTENTIALLY HAZARDOUS FOODS AT A TEMPERATURE OF 417 OR BELOW 7.EXTRA WALL PROTECTION IS REQUIRED ON WALLS BEHIND ALL SINKS, INCLUDING RESTROOM HANDWASH SINKS, AND FOOD PREPARATION COUNTERS AND TABLES. A 16—INCH HIGH BACKSPLASH OF PLASTIC LAMINATE, FIBERGLASS—REINFORCED PLASTIC OR EQUAL IS ACCEPTABLE. A BACKSPLASH HIGHER THAN 16 INCHES IS REQUIRED ON THE WALL BEHIND COUNTER TOP EQUIPMENT TALLER THAN 16 INCHES. FLOOR TO CEILING PROTECTION IS REQUIRED ON THE WALL BEHIND DISHWASHERS. WALL PROTECTION BEHIND MOP SINKS MUST COVER THE ENTIRE SPLASH ZONE. PLASTIC COATED HARDBOARD IS NOT ACCEPTABLE. 8.ALL FLOORS IN THE KITCHEN, FOOD PREPARATION, FOOD SERVICE, FOOD STORAGE, AND DISHWASHING AREAS MUST BE SURFACED WITH A DURABLE, NONABSORBENT, EASILY CLEANABLE MATERIAL. EXPANSION JOINTS, SEAMS, SAW CUTS AND THE LIKE IN CONCRETE FLOORS IN ALL AREAS, INCLUDING CUSTOMER SEATING AREAS, MUST BE FILLED AND SEALED SO AS TO PROVIDE A SMOOTH AND CLEANABLE SURFACE. 9.THE CEILING ABOVE THE FOOD PREPARATION AREAS MUST BE NONPERFORATED, NONABSORBENT, SMOOTH AND EASILY CLEANABLE. 10. ALL LIGHT FIXTURES IN FOOD PREPARATION AND STORAGE AREAS MUST BE PROVIDED WITH COVERS OR SHATTERPROOF BULBS. 1 1. PLUMBING MUST MEET STATE AND LOCAL CODES. 12. THE VENTILATION SYSTEM SHALL BE INSTALLED AND OPERATED TO MEET APPLICABLE BUILDING, MECHANICAL AND FIRE CODES. 1A.4iFS EQUIPMENT & ITEMS PROVIDED BY OWNER/TENNANT AND INSTALLED BY GENERAL CONTRACTOR. TY I No. DESCRIPTION MANUFACTURER & MODEL 1 101 FIRE EXTINGUISHER K SERIES PROVIDED BY GC INSTALLED BY GC 1 102 FIRE EXTINGUISHER 2AIOB:C PROVIDED BY GC INSTALLED BY GC 11103 MENU BOARD PROVIDED BY TENANT INSTALLED BY GC 1104 EXTERIOR SIGNAGE Salisbury Lockers Ten—Tier Plastic PROVIDED BY TENANT INSTALLED BY GC 1105 EMPLOYEE'S LOCKER MESA SAFE MLF3020EE PROVIDED BY TENANT INSTALLED BY GC 1006 SAFE PROVIDED BY TENANT INSTALLED BY GC 1 107 PROVIDED BY TENANT INSTALLED BY GC 1 108 POS PROVIDED BY TENANT INSTALLED BY GC 1 112 4' ORDER COUNTER PROVIDED BY TENANT INSTALLED BY GC 1 113 TELEPHONE SYSTEM PANASONIC KT—TG9478 PROVIDED BY TENANT INSTALLED BY GC 1 114 DEGREASER D—CARBONATOR 40 GAL PROVIDED BY TENANT INSTALLED BY GC 1 115 SELF SERVE BEVERAGE DISPENSER W ICE BIN AT TOP Coca Cola PROVIDED BY TENANT INSTALLED BY GC 1117 COFFEE MAKER Bunn VP17-2 SS (NOT SHOWN) PROVIDED BY TENANT INSTALLED BY TENA 1122 Food Processor (NOT SHOWN) Waring WFP14SW PROVIDED BY TENANT INSTALLED BY TENANI 1123 STOCK POT WARMER TURBO AIR TASP-18 PROVIDED BY TENANT INSTALLED BY GC 1124 BUN RACK CHANNEL 620 FRONT LOADING PROVIDED BY TENANT INSTALLED BY GC 1 126 Rice Warmer (NOT SHOWN) TOWN RM-55N—R 55 PROVIDED BY TENANT INSTALLED BY GC 1 133 ICE MAKER HOSHIZAKI F-330BAH—C PROVIDED BY TENANT INSTALLED BY TENANI 2 134 Microwave Oven SHARP R21 LCF PROVIDED BY TENANT INSTALLED BY GC 2 140 Exhaust Hood Captive Air PROVIDED BY GC INSTALLED BY GC 1 149 Conveyor Oven Lincoln Impinger 1 1 16000U PROVIDED BY TENANT INSTALLED BY GC 1 150 Range 24 TURBO AIR TAR -4 24 PROVIDED BY TENANT INSTALLED BY GC 1 151 Radiant Charbroiler — 48" WITH STAND STAR 6148RCBF PROVIDED BY TENANT INSTALLED BY GC 1 153 24X36 TABLE PROVIDED BY TENANT INSTALLED BY GC 1 154 Fryer, Gas FRYMASTER GF40 SD GAS FRYER PROVIDED BY TENANT INSTALLED BY GC 1 160 Walk—in Refrigeration/Freezer Box and Compressor 70X7OX56 Masterbilt PROVIDED BY TENANT INSTALLED BY GC 1 163 Refrigerated Counter, Sandwich Top TRUE TSSU-60-16 PROVIDED BY TENANT INSTALLED BY GC 1 164 Refrigrated, Work Top True TWT -36 PROVIDED BY TENANT INSTALLED BY GC 1 165 Ice Cream Freezer True TFM-29FL WHT PROVIDED BY TENANT INSTALLED BY GC 1 166 Ice Cream Dipper Well Grindmaster FW -510 dipper well & faucet PROVIDED BY TENANT INSTALLED BY GC 1 167 Ice Shaver Hatsuyuki HC 8E - DIRECT CIRCUIT REQ PROVIDED BY TENANT INSTALLED BY GC 1 169 Work Table -30" x60" ADVANCE TABCO SLAG -305 PROVIDED BY TENANT INSTALLED BY GC 1 170 Hot Food Table VOLLRATH 38105 SERVEPAN ELECTRIC FIVE PAN PROVIDED BY TENANT INSTALLED BY GC 2 171 PREP SINK ADVANCE TABCO KM SLAG-303//KMS-11B-305L WITH FAUCET PROVIDED BY TENANT INSTALLED BY GC 3—COMP RIGHT HAND SINK & FAUCET W HANDLES ELKAY 3C18X24-L-18X STANDARD SINK PROVIDED BY TENANT INSTALLED BY GC 1 173 FRE RINSE UNIT T&S B-0133-01 PRE -RINSE PROVIDED BY TENANT INSTALLED BY GC 1 174 CLEAN RIGHT HAND DISH TABLE CMA CR -36 PROVIDED BY TENANT INSTALLED BY GC 1 175 Mop Sink 24 x 24 x 10 Mustee 63M PROVIDED BY TENANT INSTALLED BY GC 2 178 TANKLESS ELECTRIC WATER HEATER NORITZ NC 250 PROVIDED BY GC INSTALLED BY GC 2 179 Hand Sink KROWNE HS -26L PROVIDED BY TENANT INSTALLED BY GC 4 180 Wall Shelves NOT SHOWN ADVANCE TABCO WS -15-96 PROVIDED BY TENANT INSTALLED BY GC 2 181 Wall Shelf for Microwave Advance Tabco MS -18-24 PROVIDED BY TENANT INSTALLED BY GC 2 182 '-Wall Wall Shelves NOT SHOWN ( ) ADVANCE TABCO WS -15-84 PROVIDED BY TENANT INSTALLED BY GC 1 183 Shelves NOT SHOWN ADVANCE TABCO WS -15-144 PROVIDED BY TENANT INSTALLED BY GC 1 184 Wall Shelves NOT SHOWN JOHN BOOS BHS1863—TS PROVIDED BY TENANT INSTALLED BY GC 1 193 Work Table -30" x 36" ADVANCE TABCO KM SLAG -303 PROVIDED BY GC INSTALLED BY GC 2 194 POT FILLER FAUCET T&S B-0594 POT FILLER FAUCET PROVIDED BY TENANT INSTALLED BY GC 1 196 GREASE INTERCEPTOR PROVIDED BY TENANT INSTALLED BY GC PROVIDED BY GC INSTALLED BY GC 1 198 SPLASH GUARD PROVIDED BY TENANT INSTALLED BY GC 3 199 FLOOR DRAIN YTENANT 1 200 CHEF BASE REFRIGERATION _ PROVIDED BY TENANT INSTALLED BY GC 1 201 CUSTOM CABINET DESIGN PER TENANT PROVIDED BY TENANT INSTALLED BY GC 2 202 SHELVING 18X48X72 PROVIDED BY TENANT INSTALLED BY GC 1 203 SHELVING 18X6OX72 PROVIDED BY TENANT INSTALLED BY GC 2 204 SHELVING 24X48X72 PROVIDED BY TENANT INSTALLED BY GC 1 205 SHELVING 24X54X72 PROVIDED BY TENANT INSTALLED BY GC 2 206 SHELVING 3OX54X72 PROVIDED BY TENANT INSTALLED BY GC 1 207 SHELVING 24X36X72 PROVIDED BY TENANT INSTALLED BY GC 1 208 SHELVING 24X48X36 PROVIDED BY TENANT INSTALLED BY GC 1 209 Chemical IS waS er Ecolab INFERNO - w/ VAPPR VENT or sim PROVIDED BY TENANT INSTALLED BY GC 1 210 SHELVING 18X36X72 PROVIDED BY TENANT INSTALLED BY GC 1 213 SOUND SYSTEM ( OPTIONAL: GC TO COORDINATE WIRING AND LOCATION WITH TENANT) PROVIDED BY TENANT INSTALLED BY GC 1 214 PREP REFRIGERATOR True TSSU-27-8-1 PROVIDED BY TENANT INSTALLED BY GC 1 215 2 DOOR REACH IN REFRIGERATOR True T-49PROVIDED BY TENANT INSTALLED BY GC 1 216 " y in" PROVIDED BY TENANT INSTALLED BY GC 4 217 300THS 63"W X 43" L SEAT 4 MILLENNIUM OAK SLAT WALL STYLE BOOTH PROVIDED BY TENANT INSTALLED BY GC 2 218 PICNIC TABLE 38 W X 74 L 3 219 PICNIC BENCHES PROVIDED BY TENANT INSTALLED BY GC 11 220 WAITING BENCH PROVIDED BY TENANT INSTALLED BY GC 1221 148" PICNIC BENCHES ALL FOOD MUST BE STORED 6" FROM FLOOR RECEIV;= CITY OF TUKWIL.A JUN 2 8 2016 RERPOI`I" CENTER } Interstate Group, Inc. Interstate Eire, Inc„ Interstate Industries, Inc. Interstate Heating and Cooing, Inc. 1217 4th Ave N. Kent, WA 98032 206-679-3268 www.interstateindustries.com MANILA SUNSET 307 TUK\DILA PARKWAY TUKWILA) WA 98188 EQUIPMENT LIST TRI -CITY ENGINEERS 4237 IRONTON DR WEST RICHLAND, WA 99353 509-531-6906 www.TRICITYENGINEERS.com DRAWN: 5/25/2016 KJE REVISED: 6/10/2016 KJE REVISED: 6/24/2016 KJE SCALE - VARIES SHEET Sl)SRkYif`t!'!�. 3OF7 SCOPE OF WORK 1. FIELD INSTALL NEW ABOVEGROUND PEX PIPING. EXISTING PLUMBING EXISTED IN THE PREVIOUS RESTAURANT, THE NEW KITCHEN DESIGN, THE UNDERGROUND PLUMBING WILL REMAIN, REUSE EXISTING GREASE TRAP. REUSE EXISTING PEX PIPE, INSTALL NEW COMPRESSION VALVES AT NEW SINKS, WITH NEW HOSES & CONNECTIONS, 1/2 WAY THROUGH THE CONSTRUCTION PHASE THE OWNER ADDED NEW ADA RESTROOM INSTALL ALL PIPING IN ACCORDANCE WITH INTERNATIONAL BUILDING CODE 2012, INTERNATIONAL MECHANICAL CODE 2012, UNIFORM PLUMBING CODE 2012 AND OTHER APPLICABLE CODES/STANDARDS. 2. EXISTING EQUIPMENT IS SHOWN FOR CLARITY. IT IS NOT PART OF THE PROJECT SCOPE. GENERAL NOTES 1. DRAWINGS REFLECT EXISTING CONDITIONS. CONTRACTOR FIELD INSTALL NEW ABOVEGROUND PEX PIPING TO SUPPLY HOT AND COLD WATER TO NEW RESTROOM. SINK & PLUMBING SCHEDULE 171 PREP SINK 171 PREP SINK 179 HAND SINK 172 3 COMP SINK 196 GREASE TRAP (EXISTING) 209 DISH WASHER 175 MOP SINK 299 HOT WATER HEATER 199 EXITING FLOOR DRAIN 201 NEW SINK AND NEW TOILET 179 HAND SINK 194 POT FILLER FAUCET NEW ADA RESTROOM ELEG PANE 0n MO £z Mz �r-9 n F- -� H z� m a FAI 40"X40" CENTER 5EE /-EXTERIOR ELEVATION NO CHANGES WILL BE MADE WITHOUT HEALTH DEPARTMENT AFFROVAL PUBLIC HEALTH - KING HEALTH DEPARTMENT INSPECTION REQUIRED UPON COMFLETION OF WORK PRIOR TO OPENING UJ STE NED VENT -=L N SCALE: 3/S`' _ V_011 R ' �v1E�P� p,NC� cm \\100" RECER(ED CITY OF TUKWILA JUN 28 2016 PERMIT CENTER Interstate Group, Inc, Interstate Eire, Inc., Interstate Industries, Inc. Interstate Heating and Cooling, Inc. 1217 4th Ave N. Kent, WA 98032 206-679-3268 www.interstateindustries.com MANILA SUNSET 307 TUKWILA PARKWAY TUKWILA, WA . .. WASTE AND VENT 1. TRI -CITY ENGINEERS 4237 IRONTON DR WEST RICHLAND, WA 99353 509-531-6906 www.TRICITYENGINEERS.com DRAWN: 5/25/2016 KJE REVISED: 6/10/2016 KJE REVISED: 6/24/2016 KJE SCALE - VARIES SHEET 4OF7 Job Name Contractor Job Lccatlon Approval Englneer Contractor's P.O. No. Approval fieprc:sentatPve Series 007 r s Double Check Valve Assemblies Sizes: 1h1t - 211 Series 007 Double Check Valve Assemblies art, damned to s protest drinkir-g vrater supptles from dari�cmus cross-connec• �ti■ `ItaBttAR tt>,...�.,.■wt�.tra�.rrtt�ltrt;tr�I ��■iiR �!�w 'A liens In accnrrfartt a 411 natiand plumbing codes and water authority "uirttments for non-potaabla service applications 1.007M1QT such as irrigallor, firellne, or industrial procoft. Only these eroso-carneGbone ldentifled by local insipeollo n authorities e3 i non -health hazard shall bo *#owed the use of an approved " double check valve assembly. Chuck vAth local auftitty, haft )trrlscllctlron regarding varttcal now orientation, fmcluency of toasting or oft, irstallotion rt tt ante, � The valve ah all meet the requirements of ASSE Std. 1,015 and AWWA Std, 0610. Approved by the Foundation for Cross - W, Connection Control and iiydrouto Research at the Unlvarwiity ofSou IMtr�sw��rr#wrt#•�_5-. Ttlt"101t��trr�;;�.+t=�sttr� them California. teoif,AtQT•S Features • Em of rnafntenanrxt - only one cover • Top way • Relolacoable seats and seat discs Modular c anstrLvtron • Compact design • Ghat bronze body construction -'A' - 2' Tcp mounted bell valve test cocks • Low pressure drop * No special tarts required for Sarvlcng • W —I I have tee handy Specifications A Double Chock 1lslve Assombfy shall ba installed at each noted location. Trio assembly shall consist of tvio possllve seating check moclules with captured sp V gs and rubber seat c18c8. The check modulo seats and seat discs shad be replaceable. S&Mce of all Internal components shall be through a slrtgte bronze or stainless; tient,/ access cover secured vAth stol s steel belts. The assembly shall dao include two reall- lent anted Isolation vahres; four top moarnted, resient seated test cocks. The assembly sMi meet the requhments of ASSE Std. 1016 acid A WA Std, 0810. Approved by the Foundation for Crom-Corraction Control and Hydrarulio Research at lhts UnNerelty of 8outhsrn Califcrria. Assembly shall be a Watts 8edea 007. drat G: sock s@Bone macro Modula Assembly Module Assembly The 007 t3arias features a madular design concept wNch facltitates complete maintenance and assembly by rets'ning the spring lead. �-Now Avi lli able , ;'i�t'lltt�i�Ct3t �i�tl�lallatt�.EilfyiCt&taraf�a. •I .. • •For mala lnftxrriation,'s�gd fCu llteraitlrit• ES WA.... Inquire, with governing autt-oritle-A for loom installation ractulrornents a'�1erraduti�liau.�rsa6cmayta'btnd rtt��asaapm�sreara�+,Ca�ttuKtc�. rarprccacm�s,ta�ncr� ad pewnfi t! *A WM4 wj ettikco rrt tart h tt tar W kftu on Mtls p Axis fr orstd►tt Nol UK %11WATM to.1,;At. Pressure — Temperature 1/al — 2" Temperature Flange: 3a'F —1 GL'F (Q.8°C — 626C). MaAmum Working Prass=, 175psi (12.1 tom, Standards ASST: Std, 1015, AWWA Std. 0510 lAPMO PS31, CSA B64.6 ag Approvals -5. t ASSE, AWWA, IAPM3, CBA, UFC A Approved by the Foundation for Gross Conneotion Control and t tydaul'io Research at the Univeraily of Southern ca�for T + Models LF and S are not listed. UL Classified (LF models o*) a/4' - 2' (except 007MM • 1-11or3zontal and v©rded "flay up, approval an all sues Dimensions - Weights Models uS• i2ev 1/2' — 2' suffix: 8 • bronze strainer LF - without shuioff varves SH - stalnless steal ball valve handles HO - 21h' Wet/oWet tiro hydrant fittings (2' valva) Prefix: U • Lt,icn connections 'Subscript 181 _ atralner model Suffix tit; -- Fire Hydrant Fittings dlmensfon "A' s 23'A' (594mm) Dimensions - Weights V UC07MOT Unica Tallploco••• Unim Nut ........ ........... .............. ............................. A .......... .._.................. Sizes: t/zn - 21, Unlon Tailpiece Union Nut NO CHANGES WILL 5E MADE WITHOUT HEALTH DEPARTMENT APPROVAL PUBLIC HEALTH - KING HEALTH DEPARTMENT INSPECTION REQUIRED UPON COMPLETION OF WORK PRIOR TO OPENING capacity Ae coy pplfad from documented Foundation for Ctoas-Conrtacum Central and Rydratn#o tlasaarch at the Un1wrolty Of 5outtlorn Wtilorala Eab fasts. yoloelm xiiflomuil system flow rata (7.5 feet/sec., 2.3 meters/se4.) UL rat4od 'h' (tttrtirn) t" sd a 1t Nu.7 iC n i a 4 .1 1 ta+t 0 4 G I,1 eta 7t4 aa4 tib las Flaw it 55 7a 43 fin 1'h" (40mm) till; 0 At7 .7 is s a a a at a a 0 93 A 114 ty >s it{t19 2" (tukrim) Id � u 7 7s ,.s a :, .4 a its 14 .a uz � 0 � km 1a to 'Ira It>� �r+ltttai rr,s>•■ttr�ttr�� '�t>•� t8�tt8aata�ttRB>�� a as s r �ti■ `ItaBttAR tt>,...�.,.■wt�.tra�.rrtt�ltrt;tr�I ��■iiR �!�w 'A t����t>�laat#�!�I t■twt��t>:tt�■rlt�'"..,:/��I, tAttl�lel��� a�•�:.rrttrt•nntattt�rrrea•ttett�ttrett. t���C#t>t�ta�l♦�n» u �■11111�ttaal i t�srte �t tt•�rae�rrrtt>•s rrrra�rwal�n�wtttrt.l now tt•ttttt•t�rttae t�ttt•�attsstaettatUotr�rAn rot IMtr�sw��rr#wrt#•�_5-. Ttlt"101t��trr�;;�.+t=�sttr� it 55 7a 43 fin 1'h" (40mm) till; 0 At7 .7 is s a a a at a a 0 93 A 114 ty >s it{t19 2" (tukrim) Id � u 7 7s ,.s a :, .4 a its 14 .a uz � 0 � km 1a to 'Ira It>� �r+ltttai rr,s>•■ttr�ttr�� '�t>•� t8�tt8aata�ttRB>�� a as s r u ut t�ltrt•rt•rt�tllw�tttt�ttl�ltil�fta>•��t now tt•ttttt•t�rttae t�ttt•�attsstaettatUotr�rAn rot IMtr�sw��rr#wrt#•�_5-. Ttlt"101t��trr�;;�.+t=�sttr� �f�f/■ �����t1i•��� �srwwrr®r��.® aalt��fr��� a� A Werra w97er Tecnn6140103 camparty ES -007 1318 DOUFDLE C EC< V LVE SCALE: N/A ajor :3.. USA: Tal: ge7$i 688.1311 • Fax tM M-1846 + �+r;��t wa la cArrs Canadat Td: Oq 332.4000 Fax: OW 332.7068 + Nw,w wst4.w l� �131'e'Otla t l�� PNCC RECEIVED CITY OF T UKWIL: JUN 28 2016 PERMIT CENTER � 5 } `�� •y �% G Interstate Group, Inc. Interstate Eire, Inc„ Interstate Industries, Inc. Interstate Heating and Cooing, Inc, 1217 4th Ave N. Kent, WA 98032 206-679-3268 www.interstateindustries.com MANILA SUNSET 307 TUKWILA PARKWAY TUKWILA, WA 98188 VALVE ASSEMBLY PRODUCT SPECS TRI -CITY ENGINEERS 4237 IRONTON DR WEST RICHLAND, WA 99353 509-531-6906 www.TRICITYENGINEERS.com DRAWN: 5/25/2016 KJE REVISED: 6/10/2016 KJE REVISED: 6/24/2016 KJE SCALE - VARIES SHEET A Y UvCtttem ,may! �'f,�i kF,$UIX. 1 zta�„sorxs�za 50F7 r �r»>w�r�tatr.r,tt�s�tt�trr.rr.rt� t�ltrt•rt•rt�tllw�tttt�ttl�ltil�fta>•��t tt•ttttt•t�rttae t�ttt•�attsstaettatUotr�rAn tt�ti•rrt•=R IMtr�sw��rr#wrt#•�_5-. Ttlt"101t��trr�;;�.+t=�sttr� �(�11■MI�^ rirrr��twt>ti rtt�rwr•■r���.w A �f�f/■ �����t1i•��� �srwwrr®r��.® aalt��fr��� a� A Werra w97er Tecnn6140103 camparty ES -007 1318 DOUFDLE C EC< V LVE SCALE: N/A ajor :3.. USA: Tal: ge7$i 688.1311 • Fax tM M-1846 + �+r;��t wa la cArrs Canadat Td: Oq 332.4000 Fax: OW 332.7068 + Nw,w wst4.w l� �131'e'Otla t l�� PNCC RECEIVED CITY OF T UKWIL: JUN 28 2016 PERMIT CENTER � 5 } `�� •y �% G Interstate Group, Inc. Interstate Eire, Inc„ Interstate Industries, Inc. Interstate Heating and Cooing, Inc, 1217 4th Ave N. Kent, WA 98032 206-679-3268 www.interstateindustries.com MANILA SUNSET 307 TUKWILA PARKWAY TUKWILA, WA 98188 VALVE ASSEMBLY PRODUCT SPECS TRI -CITY ENGINEERS 4237 IRONTON DR WEST RICHLAND, WA 99353 509-531-6906 www.TRICITYENGINEERS.com DRAWN: 5/25/2016 KJE REVISED: 6/10/2016 KJE REVISED: 6/24/2016 KJE SCALE - VARIES SHEET A Y UvCtttem ,may! �'f,�i kF,$UIX. 1 zta�„sorxs�za 50F7 SCOPE OF WORK 2. FIELD INSTALL NEW ABOVEGROUND PEX PIPING. EXISTING PLUMBING EXISTED IN THE PREVIOUS RESTAIIRANIT TI -IF NEW KITCHEN DESIGN, THE UNDERGROUND I REMAIN, REUSE EXISTING GREASE TRAP. REL PEX PIPE, INSTALL NEW COMPRESSION VALV SINKS, WITH NEW HOSES & CONNECTIONS, THROUGH THE CONSTRUCTION PHASE THE C NEW ADA RESTROOM INSTALL ALL PIPING IN WITH INTERNATIONAL BUILDING CODE 2012) MECHANICAL CODE 2012, UNIFORM PLUMBI 2012 AND OTHER APPLICABLE CODES/STAN[ EXISTING EQUIPMENT IS SHOWN FOR CLARIT' PART OF THE PROJECT SCOPE. GENERAL NOTES 1. DRAWINGS REFLECT W FIELD INSTALL NEW SUPPLY HOT AND EXISTING CONDITIONS. C ABOVEGROUND PEX PIPI COLD WATER TO NEW RE`. A R E SINK 8c PLUMBING SCHEDULE 171 PREP SINK 171 PREP SINK 179 HAND SINK 172 3 COMP SINK 196 GREASE TRAP (EXISTING) 209 DISH WASHER 175 MOP SINK 299 HOT WATER HEATER 199 EXITING FLOOR DRAIN 201 NEW SINK AND NEW TOILET 179 HAND SINK 194 POT FILLER FAUCET -rn r A <- AA r Trfl /-\ THROUGH ROOF T0� APPLIANCES MAKE—UP AIR UNITAR NO CHANCES UJILL 5E MADE UJITHOUT HEALTH DEPARTMENT APPROVAL PU5LIC HEALTH - KING HEALTH DEPARTMENT INSPECTION REQUIRED UPON COMPLETION OF UjORK PRIOR TO OPENING FRO 01= L N SCALE: 3/S" = V -0" 0 oF0 °° �° .<� 01216 G�'� 0 a SSC gV1Lowe RECEIVED CITY OF TUI(WILA JUS! 28 2016 PERMIT CENTER Interstate Group, Inc, Interstate Fire, Inc„ Interstate Industries, Inc. Interstate Heating and Cooling, Inc, 1217 4th Ave N. Kent, WA 98032 206-679-3268 www.interstateindustries.com MANILA SUNSET 307 TUKWILA PARKWAY TUKWILA, WA 98188 ROOF PLAN TRI -CITY ENGINEERS 4237 IRONTON DR WEST RICHLAND, WA 99353 509-531-6906 www.TRICITYENGINEERS.com D RAW N : 5/25/2016 KJ E REVISED: 6/10/2016 KJE REVISED: 6/24/2016 KJE SCALE - VARIES SHEET 6OF7 SCOPE OF WORK 1. FIELD INSTALL NEW ABOVEGROUND PEX PIPING. EXISTING PLUMBING EXISTED IN THE PREVIOUS RESTAURANT, THE NEW KITCHEN DESIGN, THE UNDERGROUND PLUMBING WILL REMAIN, REUSE EXISTING GREASE TRAP. REUSE EXISTING PEX PIPE, INSTALL NEW COMPRESSION VALVES AT NEW SINKS, WITH NEW HOSES & CONNECTIONS, 1/2 WAY THROUGH THE CONSTRUCTION PHASE THE OWNER ADDED NEW ADA RESTROOM INSTALL ALL PIPING IN ACCORDANCE WITH INTERNATIONAL BUILDING CODE 2012, INTERNATIONAL MECHANICAL CODE 2012, UNIFORM PLUMBING CODE 2012 AND OTHER APPLICABLE CODES/STANDARDS. 2. EXISTING EQUIPMENT IS SHOWN FOR CLARITY. IT IS NOT PART OF THE PROJECT SCOPE. GENERAL NOTES 1. DRAWINGS REFLECT EXISTING CONDITIONS. CONTRACTOR TO FIELD INSTALL NEW ABOVEGROUND PEX PIPING TO SUPPLY HOT AND COLD WATER TO NEW RESTROOM. I I GAS SUPPL TO ROOF GAS SUPPL TO ROOF I GAS LINE DETAIL ------ ------ ------ ------ GAS LINE DETAIL SINK 8c PLUMBING SCHEDULE 171 PREP SINK 171 PREP SINK 179 HAND SINK 172 3 COMP SINK 196 GREASE TRAP (EXISTING) 209 DISH WASHER 175 MOP SINK 299 HOT WATER HEATER 199 EXITING FLOOR DRAIN 201 NEW SINK AND NEW TOILET 179 HAND SINK 194 POT FILLER FAUCET 7 A I :a 2 Q GAS APPLIANCE SCHEDULE AR N0. APPLIANCE 123 24" STOCK POT WARMER 149 (2) COMBINATION OVEN 48" 154 36" (2) 151 60" 154 24" STOVE -BURNER FLATTOP ON -DEMAND WATER CHARBROILER FLAT HEATER ELEC PANE GAS CONSUMPTION 200BTU 3013TU/3013TU 150BTU 120BTU 150BTU 250BTU 40"X40" CENTER NO CNAHCsES WILL BE MADE WITHOUT HEALTH DEPARTMENT APPROVAL PUBLIC HEALTH - KING HEALTH DEPARTMENT INSPECTION REQUIRED UPON COMPLETION OF UIORIC PRIOR TO OPENING : = L f= I FING N 5CALE: 3/a" = V-0 > G RECEIVED CITY OF TUKWILA JUIN 2 8 2016 PERMIT CENTER Interstate Group, Inc. Interstate Eire, Inc„ Interstate Industries, Inc, Interstate Heating and Cooing, Inc. 1217 4th Ave N. Kent, WA 98032 206-679-3268 www.interstateindustries.com MANILA SUNSET 307 TUKWILA PARKWAY TUKWILA, WA 98188 GAS PIPING AND DETAILS 1 0 i 4237 IRONTON DR WEST RICHLAND, WA 99353 509-531-6906 www.TRICITYENGINEERS.com DRAWN: 5/25/2016 KJE REVISED: 6/10/2016 KJE REVISED: 6/24/2016 KJE SCALE - VARIES SHEET 7OF7