HomeMy WebLinkAboutPermit PG16-0023 - HERNANDEZ RESIDENCE - GAS WATER HEATER REPLACEMENTHERNAND RESIDENCE
13727 43 PL S
PG16-0023
City of Tukwila
Department of Community Development
• 6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone; 206-431-3670
Inspection Request Line: 206-438-9350
Web site: http://www.TukwilaWA.gov
WATER HEATER PERMIT
Parcel No: 2612000300
Address: 13727 43RD PL S
Project Name: HERNANDEZ RESIDENCE
Owner:
Name: HERNANDEZJORGE
Address: 13727 43RD PL S, TUKWILA, WA,
98168
Contact Person:
Name:
KATY KEHLE
Address:
11715 N CREEK PKWY S #C-106,
International Residential Code Edition:
BOTHELL, WA, 98011
Contractor:
2014
Name:
FAST WATER HEATER COMPANY
Address:
11715 N CREEK PKWY S STE C-106,
Uniform Plumbing Code Edition:
BOTHELL, WA, 98011
License No:
FASTWWH948BC
Lender:
2012
Name:
Address:
DESCRIPTION OF WORK:
REMOVE REPLACE GAS WATER HEATER
Permit Number: PG16-0023
Issue Date: 3/1/2016
Permit Expires On: 8/28/2016
Phone: (425) 636-7084
Phone: (425) 636-7084
Expiration Date: 1/4/2018
Valuation of Work: $1,994.00 Fees Collected: $48.83
Water District: 125
Sewer District: VALLEY VIEW SEWER SERVICE
Current Codes adopted by the City of Tukwila:
International Building Code Edition:
2012
National Electrical Code:
2014
International Residential Code Edition:
2012
WA Cities Electrical Code:
2014
International Mechanical Code Edition:
2012
WAC 296-46B:
2014
Uniform Plumbing Code Edition:
2012
WA State Energy Code:
2012
International Fuel Gas Code:
2012
Permit Center Authorized Signatu
Date:
I hearby certify that I have read and examined this permit and know the same to be true and correct. All
provisions of law and ordinances governing this work will be complied with, whether specified herein or not.
The granting of this permit does not presume to give authority to violate or cancel the provisions of any other
state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this
development per itand gree to the con ' ' ns attached to this permit.
Signatur Date: /6""
Print Nam • [�
This permit shall become null and void if the work is not commenced within 180 days for the date of issuance, or if
the work is suspended or abandoned for a period of 180 days from the last inspection.
PERMIT CONDITIONS:
1: ***PLUMBING/GAS PIPING PERMIT CONDITIONS***
2: No changes shall be made to applicable plans and specifications unless prior approval is obtained from the
Tukwila Building Division.
3: All permits, inspection records and applicable plans shall be maintained at the job and available to the
plumbing inspector.
4: All plumbing and gas piping systems shall be installed in compliance with the Uniform Plumbing Code and
the Fuel Gas Code.
S: No portion of any plumbing system or gas piping shall be concealed until inspected and approved.
6: All plumbing and gas piping systems shall be tested and approved as required by the Plumbing Code and
Fuel Gas Code. Tests shall be conducted in the presence of the Plumbing Inspector. It shall be the duty of
the holder of the permit to make sure that the work will stand the test prescribed before giving notification
that the work is ready for inspection.
7: No water, soil, or waste pipe shall be installed or permitted outside of a building or in an exterior wall
unless, adequate provision is made to protect such pipe from freezing. All hot and cold water pipes
installed outside the conditioned space shall be insulated to minimum R-3.
8: Plastic and copper piping running through framing members to within one (1) inch of the exposed framing
shall be protected by steel nail plates not less than 18 guage.
9: Piping through concrete or masonry walls shall not be subject to any load from building construction. No
plumbing piping shall be directly embedded in concrete or masonry.
10: All pipes penetrating floor/ceiling assemblies and fire -resistance rated walls or partitions shall be protected
in accordance with the requirements of the building code.
11: Piping in the ground shall be laid on a firm bed for its entire length. Trenches shall be backfilled in thin
layers to twelve inches above the top of the piping with clean earth, which shall not contain stones,
boulders, cinderfill, frozen earth, or construction debris.
12: The issuance of a permit or approval of plans and specifications shall not be construed to be a permit for, or
an approval of, any violation of any of the provisions of the Plumbing Code or Fuel Gas Code or any other
ordinance of the jurisdiction.
13: The applicant agrees that he or she will hire a licensed plumber to perform the work outlined in this permit.
14: All new plumbing fixtures installed in new construction and all remodeling involving replacement of
plumbing fixtures in all residential, hotel, motel, school, industrial, commercial use or other occupancies
that use significant quantities of water shall comply with Washington States Water Efficiency ad
Conservation Standards in accordance with RCW 19.27.170 and the 2006 Uniform Plumbing Code Section
402 of Washington State Amendments
PERMIT INSPECTIONS REQUIRED
Permit Inspection Line: (206) 438-9350
1900 PLUMBING FINAL
8005 ROUGH -IN PLUMBING
CITY OF TUKWTT A
Community Developn. Department
Permit Center
6300 Southcenter Blvd., Suite 100
Tukwila, WA 98188
http./..!www.TukwilaWA.,gov
Plumbing/C Permit No.
Project No.
Date Application Accepted:
Date Application Expires: _
use
PLUMBING / GAS PIPING PERMIT APPLICATION
Applications and plans must be complete in order to be accepted for plan review.
Applications will not be accepted through the mail or by fax.
"Please Print"
SITE LOCATION
�f, �[ U 1� �i PLKing o Assessor's Tax No.: �c � d — 0 3 b 0
Site Address: ' ✓9-�� S / rr V A Suite Number: Floor:
Tenant Name: (� �� GDE—New Tenant: ❑ ..... Yes C<.. No
PROPERTY OWNER n , /
Name: 3-6
L- HFP-i�A-t,,]DF�
Address: L4 5f -DL, f
Cityj-L TT State: WA— Zip:
CONTACT PERSON — person receiving all project
communication f 1
Name: KAT`/ i�Tl L
Address: 111L l 0 C el Y -W 7 S -kl I p
City: bo j l „ „''11 t ` State: Zip:
Phone: qa5-& J C� Fax: 3�
Email: KK�,N1�@ S'`"w ctiN)
PLUMBING CONTRACTOR INFORMATION
Company Name: fA ST
Address: I I i5 N ck�-r�
City: r,Li . 1, State:wZip:��p'
Phone:�a, Vb�X�(,1 Vo`1 Fax:L gSJ (_,,j n
Contr Reg No.: f ASTWw Vk L1L1% Exp Date:', , f
Tukwila Business License No.:
Valuation of Project (contractor's bid price):
Scope of Work (please provide detailed information): -e Vy) by-ely-?p \ a LL O J
Building Use (per Int'l Building Code):
Occupancy (per Int'1 Building Code):
Utility Purveyor: Water:
H:\Applications\Forms-Applications On Line\2011 Applications\Plumbing Permit Application Revised 8-9-1 I.docx
Revised: August 2011
bh
Sewer:
Page 1 of 2
Indicate type of plumbing fixtures and/e s piping outlets being installed and the quant' elow:
Fixture Type
Qty
Bathtub or combination
bath/shower
Dishwasher, domestic with
independent drain
Shower, single head trap
Sinks
i
Rain water system — per
drain (inside building)
Grease interceptor for
commercial kitchen (>750
gallon capacity)
Each additional medical
gas inlets/outlets greater
than5
Atmospheric -type vacuum
breakers not included in
lawn sprinkler backflow
protections (1-5)
Fixture Type
Qty
Bidet
Drinking fountain or water
cooler (per head)
Lavatory
Urinal
Water heater and/or vent
i
Repair or alteration of
water piping and/or water
treatment equipment
Backflow protective device
other than atmospheric -
type vacuum breakers 2
inch (51 mm) diameter or
smaller
Atmospheric -type vacuum
breakers not included in
lawn sprinkler backflow
rotections over 5
Fixture Type
Qty
Clothes washer,
domestic
Food -waste grinder,
commercial
Wash fountain
Water closet
Industrial waste
treatment interceptor,
including trap and vent,
except for kitchen type
grease interceptors
Repair or alteration of
drainage or vent piping
Backflow protective
device other than
atmospheric -type
vacuum breakers over 2
inch (51 mm) diameter
Gas piping outlets
Fixture Type
Qty
Dental unit, cuspidor
Floor drain
Receptor, indirect waste
Building sewer and each
trailer park sewer
Each grease trap
(connected to not more
than 4 fixtures - <750
gallon capacity
Medical gas piping
system serving 1-5
inlets/outlets for a specific
gas
Each lawn sprinkler
system on any one meter
including backflow
protection devices
PERMIT APPLICATION NOTES -
Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject
to possible revision by the Permit Center to comply with current fee schedules.
Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation.
The Building Official may grant one extension of time for an additional period not to exceed 180 days. The extension shall be requested in writing
and justifiable cause demonstrated. Section 103.4.3 International Plumbing Code (current edition).
I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER
PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT.
BUILDING OWNER OR AUT//�HO ZED AGENT:
Signature: _ I , Date: C�— 0 Ll
Print Name: ll D,��ayT,el^ephone: —105 14,2 D 7 y
Mailing Address: I i 3-15 N1Gt�C� Pt -W -1 S 0 C— I b 111 , B(3f V k I I. tI/A— g K b l i
City State Zip
H:Wpplications\Forms-Applications On Line\2011 Applications'Plumbing Permit Application Revised 8-9-11.docx
Revised: August 2011 Page 2 of 2
bh
DESCRIPTIONS
PermitTRAK
$48.83
PG16-0023 Address: 13727 43RD PL S
Apn: 2612000300
$48.83
PLUMBING
$46.50
PERMIT ISSUANCE BASE FEE
R000.322.100.00.00 0.00
$32.50
WATER HEATER FIXTURE FEE
R000.322.103.00.00 0.00
$14.00
TECHNOLOGY FEE
$2.33
TECHNOLOGY FEE
TOTAL FEES PAID BY RECEIPT: R7785
R000.322.900.04.00 0.00
$2.33
$48.83
Date Paid: Tuesday, March 01, 2016
Paid By: FAST WATER HEATER COMPANY
Pay Method: CHECK 20611
Printed: Tuesday, March 01, 2016 10:26 AM 1 of 1 CR?
SYSTEMS
3
INSPECTION RECORD
Z Retain a copy with pe. t 2,
INSPECTION NO. PERMIT NO.
CITY OF TUKWILA BUILDING DIVISION
6300 Southcenter Blvd., #100; Tukwila. WA 98188(06) 431-3670
Permit Inspection Request Line (206) 438-9350 F( � I�
Proje t:
Type of Insp99e,ctio�'i{n-'.-,
Vl rn
Address:
15 7
Date Cali .
Special Instructions:
AA
f ��l
Date anted: a.m.
p.m.
Requester:
Phone No:
REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be
paid at 6300 Southcenter Blvd„ Suite 100. Call to schedule reinspection.
0
INSPECTION RECORD--`Z
ECORD�'�,Z L3
Retain a copy with perm
NSPECTION NO. PERMIT NO.
CITY OF TUKWILA BUILDING DIVISION
6300 Southcenter Blvd., #100, Tukwila. WA 98188 C (206) 431-3670
Permit Inspection Request Line (206) 438-9350 IFt K4 (
Project:
��
Type of Inspection:
0
Address:. �
13-7 Z7
� f�
S ,
Date Call
Special Instructions:.
fa�
�
Date Wa t
•v
a.m.
p.m.
Requ sten.
Phone No:
ElApproved per applicable codes. Corrections required prior to approval.
COMMENTS:
I011
Inspector: Date:
REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be
paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection.
FAST WATER HEATER COMPAI T
Safety & Health
Washington State Department of
Labor & !industries
FAST WATER HEATER COMPANY
Owner or tradesperson
Principals
JORDAN, JEFFERY
DAVID, PARTNER/MEMBER
HANLEYBROWN,
JASON, PARTNER/MEMBER
Doing business as
FAST WATER HEATER COMPANY
WA UBI No.
602 564 544
Parent company
FWH ACQUISITION COMPANY LLC
Horne Espanol COTIhA ..
Claims & Insurance
Page 1 of 4
p
A -'L, Index Help Dov L&1:
Workplace Rights Trades & Licensing
11715 N CREEK PARKWAYS, C-106
BOTHELL, WA98011
425-814-8381
KING County
Business type
Limited Liability Company
Governing persons
JASON
HANLEYBROWN
JEFFREY DAVID JORDAN;
License
Verify the contractor's active registration / license / certification (depending on trade) and any past violations.
Construction Contractor Active.
...........................................................................
Meets current requirements.
License specialties
GENERAL
$1,000,000.00
License no.
FASTWWH948BC
Effective — expiration
Effective date
01/03/2006— 01/04/2018
02/17/2014
Bond
.................
Expiration date
DEVELOPERS SURETY & INDEM CO
$12,000.00
Bond account no.
549792C
Received by L&I
Effective date
01/03/2006
01/01/2005
Expiration date
Until Canceled
Insurance
............................
American States Insurance Co
$1,000,000.00
Policy no.
01CISS607620
Received by L&I
Effective date
01/25/2016
02/17/2014
Expiration date
02/17/2017
Insurance history