HomeMy WebLinkAboutPermit PG16-0039 - US DEPT OF HOMELAND SECURITY - SINK AND HOT WATER HEATERUS DEPT OF HOMELAND SECURITI' 12500 TUKWILA INT'L BLVD PG16-0039 . City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Inspection Request Line: 206-438-9350 Web site: http://www.TukwilaWA.Rov PLUMBING/GAS PIPING PERMIT Parcel No: Address: Project Name: 7340600602 12500 TUKWILA INTERNATIONAL BLVD US DEPT OF HOMELAND SECURITY Permit Number: PG16-0039 Issue Date: 4/1/2016 Permit Expires On: 9/28/2016 Owner: International Residential Code Edition: 2012 Name: INTERNATIONAL GATEWAY EAST International Mechanical Code Edition: Address: 12201 TUKWILA INTL BLVD 4TH FL, 2014 Uniform Plumbing Code Edition: SEATTLE, WA, 98168 WA State Energy Code: Contact Person: International Fuel Gas Code: 2012 Name: JIM THOMAS Phone: (206) 763-4819 Address: . 5005 THIRD AVE S, SEATTLE, WA, 98134 Contractor: Name: MCKINSTRY CO LLC Phone: (206) 762-3311 Address: PO BOX 24567, SEATTLE, WA, 98134 License No: MCKINCL942DW Expiration Date: 3/16/2018 Lender: Name: Address: DESCRIPTION OF WORK: INSTALL SINK AND INSTA HOT WATER HEATER Valuation of Work: $8,012.00 Fees Collected: $144.96 Water District: 20,125,TUKWILA Sewer District: VALLEY VIEW SEWER SERVICE Current Codes adopted by the City of Tukwila: International Building Code Edition: 2012 National Electrical Code: 2014 International Residential Code Edition: 2012 WA Cities Electrical Code: 2014 International Mechanical Code Edition: 2012 WAC 296-46B: 2014 Uniform Plumbing Code Edition: 2012 WA State Energy Code: 2012 International Fuel Gas Code: 2012 Permit Center Authorized Signature: 1N N I Date: I I hearby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this development permit and agre;to the conditions attached to this permit. 1-1 Sign Print Name: L/ UZ%y\/ rwm4 5 Date: V^ This permit shall become null and void if the work is not commenced within 180 days for the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. PERMIT CONDITIONS: 1: ***PLUMBING/GAS PIPING PERMIT CONDITIONS*** 2: No changes shall be made to applicable plans and specifications unless prior approval is obtained from the Tukwila Building Division. 3: All permits, inspection records and applicable plans shall be maintained at the job and available to the plumbing inspector. 4: All plumbing and gas piping systems shall be installed in compliance with the Uniform Plumbing Code and the Fuel Gas Code. 5: No portion of any plumbing system or gas piping shall be concealed until inspected and approved. 6: All plumbing and gas piping systems shall be tested and approved as required by the Plumbing Code and Fuel Gas Code. Tests shall be conducted in the presence of the Plumbing Inspector. It shall be the duty of the holder of the permit to make sure that the work will stand the test prescribed before giving notification that the work is ready for inspection. 7: No water, soil, or waste pipe shall be installed or permitted outside of a building or in an exterior wall unless, adequate provision is made to protect such pipe from freezing. All hot and cold water pipes installed outside the conditioned space shall be insulated to minimum R-3. 8: Plastic and copper piping running through framing members to within one (1) inch of the exposed framing shall be protected by steel nail plates not less than 18 guage. 9: Piping through concrete or masonry walls shall not be subject to any load from building construction. No plumbing piping shall be directly embedded in concrete or masonry. 10: All pipes penetrating floor/ceiling assemblies and fire -resistance rated walls or partitions shall be protected in accordance with the requirements of the building code. 11: Piping in the ground shall be laid on a firm bed for its entire length. Trenches shall be backfilled in thin layers to twelve inches above the top of the piping with clean earth, which shall not contain stones, boulders, cinderfill, frozen earth, or construction debris. 12: The issuance of a permit or approval of plans and specifications shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the Plumbing Code or Fuel Gas Code or any other ordinance of the jurisdiction. 13: The applicant agrees that he or she will hire a licensed plumber to perform the work outlined in this permit. 14: All new plumbing fixtures installed in new construction and all remodeling involving replacement of plumbing fixtures in all residential, hotel, motel, school, industrial, commercial use or other occupancies that use significant quantities of water shall comply with Washington States Water Efficiency ad Conservation Standards in accordance with RCW 19.27.170 and the 2006 Uniform Plumbing Code Section 402 of Washington State Amendments PERMIT INSPECTIONS REQUIRED Permit Inspection Line: (206) 438-9350 8004 GROUNDWORK 1900 PLUMBING FINAL 8005 ROUGH -IN PLUMBING CITY OF TUKWI- • Community Development Department Permit Center • 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://www.TukwilaWA.gov Plumbing/Gas Permit NoP6 1�za Project No. Date Application Accepted: Date Application Expires: use PLUMBING / GAS PIPING PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. "Please Print" SLTE LOCATION King Co Assessor's Tax No.: 7340600602 Site Address: 12500 International Blvd Suite Number: Floor: 4th Tenant Name: US Department of Homeland Security New Tenant: ❑ .....Yes ®..No PROPERTY OWNER Name: International Gateway East Address: 12201 Tukwila International Blvd 4th Floor City: Tukwila State: WA Zip: 98168 CONTACT PERSON — person receiving all project communication Name: Jim Thomas w/ McKinstry Co LLC Address: 5005 3rd Ave S City: Seattle State: WA Zip: 98134 Phone: (206) 763-481.9 Fax: (206) 762-2624 Email: permits@mckinstry.com It Q Valuation of Project (contractor's bid price): S V 1 0 �Z Scope of Work (please provide detailed information): Install sink and insta-hot water heater. Building Use (per Int'1 Building Code): Occupancy (per Int'l Building Code): Utility Purveyor: Water: PLUMBING CONTRACTOR INFORMATION Company Name: McKinstryCo LLC Address: 5005 3rd Ave S City: Seattle State: WA Zip: 98134 Phone: (206) 762-3311 Fax: (206) 762-2624 Contr Reg No.: MCKINCL942DW Exp Date: 03/16/2018 Tukwila Business License No.: BUS -0994320 Sewer: H:•Applications Forms -Applications On Line'.2011 Applications`,Plumbing Permit Application Revised 8-9-1 l.docx Revised: August 2011 Page 1 of 2 bh Indicate type of plumbing fixtures and/or € .- ,)iping outlets being installed and the quantity 1,--.,w: Fixture Type Qty Bathtub or combination bath/shower Dishwasher, domestic with independent drain Shower, single head trap Sinks 1 Rain water system — per drain (inside building) Grease interceptor for commercial kitchen (>750 gallon capacity) Each additional medical gas inlets/outlets greater than 5 Atmospheric -type vacuum breakers not included in lawn sprinkler backflow protections (1-5) Fixture Type Qty Bidet Drinking fountain or water cooler (per head) Lavatory Urinal Water heater and/or vent 1 Repair or alteration of water piping and/or water treatment equipment Backflow protective device other than atmospheric - type vacuum breakers 2 inch (51 mm) diameter or smaller Atmospheric -type vacuum breakers not included in lawn sprinkler backflow protections over 5 PERMIT APPLICATION NOTES - Fixture Type Qty Clothes washer, domestic Food -waste grinder, commercial Wash fountain Water closet Industrial waste treatment interceptor, including trap and vent, except for kitchen type ease interceptors Repair or alteration of drainage or vent piping Backflow protective device other than atmospheric -type vacuum breakers over 2 inch (51 mm) diameter Gas piping outlets Fixture Type Qty Dental unit, cuspidor Floor drain Receptor, indirect waste Building sewer and each trailer park sewer Each grease trap (connected to not more than 4 fixtures - <750 gallon capacity Medical gas piping system serving 1-5 inlets/outlets for a specific as Each lawn sprinkler system on any one meter including backflow protection devices Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation The Building Official may grant one extension of time for an additional period not to exceed 180 days. The extension shall be requested in writing and justifiable cause demonstrated. Section 103.4.3 International Plumbing Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING Signature 4pl^ Print Na4e:/ Jim Thomas w/ McKinstry Co LLC Mailing Address: 5005 3rd Ave S C ze Date: 03/17/2016 Day Telephone: (206) 763-4819 Seattle 0 WA 98134 City State Zip H:\Applications\Forms-Applications On Line101 I ApplicationsTlumbing Permit Application Revised 8-9-1 I.docx Revised: August 2011 Page 2 of 2 bh DESCRIPTIONS PermitTRAK • QUANTITY PAID $586.84 M16-0043 Address: 12500 TUKWILA INTERNATIONAL BLVD Apn: 7340600602 $441.88 MECHANICAL $424.88 PERMIT ISSUANCE BASE FEE R000.322.100.00.00 0.00 $32.50 PERMIT FEE R000.322.100.00.00 0.00 $307.40 PLAN CHECK FEE R000.322.102.00.00 0.00 $84.98 TECHNOLOGY FEE $17.00 TECHNOLOGY FEE R000.322.900.04.00 0.00 $17.00 PG16-0039 Address: 12500 TUKWILA INTERNATIONAL BLVD Apn: 7340600602 $144.96 PLUMBING $139.38 PERMIT ISSUANCE BASE FEE R000.322.100.00.00 0.00 $32.50 PERMIT FEE R000.322.100.00.00 0.00 $79.00 PLAN CHECK FEE R000.322.103.00.00 0.00 $27.88 TECHNOLOGY FEE $5.58 TECHNOLOGY FEE TOTAL FEES PAID BY RECEIPT: R7963 R000.322.900.04.00 0.00 $5.58 $586.84 Date Paid: Friday, March 18, 2016 Paid By: MCKINSTRY Pay Method: CREDIT CARD 095508 Printed: Friday, March 18, 2016 3:27 PM 1 of 1 (rpP SYSTEMS INSPECTION RECORD v Retain a copy with permit 3 INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Pro'e(ct: a.S t �'S`e CC Type flnspection: �C Address: moo (✓ Date Called: Special Instructions: Date Wante ! a.m4-A Ll. e : Re)W. �( Phone No: REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100.. Call to schedule reinspection. INSPECTION RECORD Retain a copy with permit jr � �0 IN ECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Pro'ect: Typnf Inspection: ti. PNt+'l� Address: Date call6j. Specia-I 1ristiluctions: Date Wanted: ` a.m. P.M. Requester: L�6itct.r�f Gc��i( o Phone No: _ 10b--f)i611 ZA Ilnspector: t/, / IDate _ [6 _ r� F] REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd„ Suite 100. Call to schedule reinspection. MA INSPECTION RECORD Retain a copy with permit�� ECTION N0. PERMIT N0. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 206) 431-3670 Permit Inspection Request Line (206) 438-9350 KO I.LC,� Project: Type of Inspectio Address: Date Called: Special Instructions: Date Wanted: a.m. p.m. Req ste / cg(( Phone No: REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. HERMIT COORD COPY PLAN REVIEW/ROUTING SLIP PERMIT NUMBER: PG16-0039 DATE: 03/22/16 PROJECT NAME: US DEPARTMENT OF HOMELAND SECURITY SITE ADDRESS: 12500 INTI BLVD X Original Plan Submittal Response to Correction Letter # DEPARTMENTS: ki AWD IhllI')lg Building Division JJ6 NA 144 Public Works IN PRELIMINARY REVIEW: Not Applicable ❑ (no approval review required) REVIEWER'S INITIALS: APPROVALS OR CORRECTIONS: Approved ❑ Corrections Required ❑ (corrections entered in Reviews) Notation: REVIEWER'S INITIALS: Revision # before Permit Issued Revision # after Permit Issued Fire Prevention ❑ Structural ❑ Planning Division ❑ Permit Coordinator ❑ DATE: 03/24/16 Structural Review Required ❑ DATE: DUE DATE: 04/21/16 Approved with Conditions ❑ Denied ❑ (ie: Zoning Issues) DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: 12/18/2013 MCKINSTRY CO LLC Home Espahol Contact Safety & Health Washington State Department of Labor & Industries MCKINSTRY CO LLC Owner or tradesperson Principals ALLEN, DEAN CHARLES, PARTNER/MEMBER MOORE, DOUGLAS JAMES, PARTNER/MEMBER ALLEN, DAVID EDWARD, PARTNER/MEMBER TEPLICKY, JOSEPH WILLIAM, PARTNER/MEMBER PEDERSEN, JAMIE D, AGENT Doing business as MCKINSTRY CO LLC Page 1 of 3 Search L&I A -'Z, Index Help My I..&I Claims & Insurance Workplace Rights Trades & Licensing PO BOX 24567 SEATTLE, WA 98134 206-762-3311 KING County WA UBI No. Business type 602 569 922 Limited Liability Company License Verify the contractor's active registration / license / certification (depending on trade) and any past violations. Construction Contractor Active. _.............................................................. _....... Meets current requirements. License specialties $2,000,000.00 GENERAL License no. MCKINCL942DW Effective date Effective — expiration 01131/2014 03/16/2006— 03/16/2018 Expiration date Bond ................. 01/31/2017 WESTERN SURETY CO $12,000.00 Bond account no. 929511574 Received by L&I Effective date 09/02/2010 09/09/2010 Expiration date Until Canceled Bond history Insurance Travelers Indemnity Company Th $2,000,000.00 Policy no. VTC2KC05643B9011N D14 Received by L&I Effective date 12/08/2015 01131/2014 Expiration date 01/31/2017 https://secure,Ini.wa.gov/verify/Detail.aspx?UBI=602569922&LIC=MCKINCL942DW&SAW= 4/1/2016 PIPING & PLR A UIVIBING SYMBOLS & ABBREVIATIONS CD COND CONDENSATE DRAIN PIPE CDS CDS CONDENSER WATER SUPPLY ------CDR------ CDR CONDENSER WATER RETURN -------CHR ------ CHR CHILLED WATER RETURN CHS CHS CHILLED WATER SUPPLY - - CW COLD WATER G G NATURAL GAS - - - - HW HOT WATER - - - - - - HWC HOT WATER RECIRC -------------- HWR HOT WATER RETURN HWS HOT WATER SUPPLY RL REFRIGERANT LIQUID LINE RS REFRIGERANT SUCTION LINE ------------------ V VENT ABOVE GROUND V VENT UNDER GROUND W WASTE ABOVE GROUND W WASTE UNDER GROUND FITTINGS N/A I -D DN ELBOW DOWN SLOPE --+0 UP ELBOW UP - FLOW DIRECTION --I r -I- DN TEE DOWN REDUCER; INCREASER --K>+-- UP TEE UP -III- UNION 1 CAP PIPE CAP -II-- FLANGE -? BREAK SYMBOL FLEX CONNECTION 11 WCO WALL CLEANOUT UPC CHAPTER 7 C FCO FLOOR CLEANOUT N/A EQUIPMENT OPERATING PRESSURE UP TO 5 PSI PUMP AIRVENT AUTO A SHOCK ARRESTOR AIRVENT MANUAL FLOW SWITCH THERMOMETER FLOW METER - PIPE SLEEVE PRESSURE GAUGE FD FLOOR DRAIN --CD-- EXPANSION TANK QO RD ROOF DRAIN -1,; 1 Y -STRAINER Q OFD OVERFLOW DRAIN ® FS FLOOR SINK VALVES MOTOR VALVE 3 -WAY MOTOR VALVE PRESSURE REDUCING VALVE 3 -WAY GATE VALVE CONTROL VALVE DIAPHRAGM VALVE RELIEF VALVE -loF-- PLUG VALVE --16 F---- BALL VALVE ANGLE GLOBE VALVE GATE VALVE NEEDLE VALVE BUTTERFLY VALVE QI- BALANCING VALVE -i/�- CHECK VALVE HOSE BIBB I a SPRING LOADED CHECK VALVE PLUMBING FIXTURE SCHEDULE TAG MODEL CONNECTION NOTES CW HW TEMP W V S-1 SINGLE COMPARTMENT KITCHEN SINK (ADA) & JACKETING CW & HW HWC (POTABLE) COLD WATER (DOMESTIC) DOMESTIC HOT AND COLD WATER SERVICE HOT WATER to 160 DEG F(DOMESTIC) COMPLY WITH NSF -61 AND NSF 372 HOT WATER CIRCULATION TO 160 DEG F. FIXTURE: FAUCET: DRAIN: TRAP: SUPPLIES: ELKAY CELEBRITY GECR 2521 SINK KOHLER TRIOTON/FINESS FAUCET 5-7776-5 WITH K-16012-5 WMST BLADES JUST J-35 CRUMB CUP WITH 1-1/2" TAILPIECE ZURN Z8702 -PC -BX, 1-1/2" X 1-1/2", 17 GAUGE CHROME PLATED BRASS 20" CHROME SUPPLIES W/ 1/2" NOM. X 3/8" COMP. ANGLE STOP AND ESCUTCHEON, LOOSE KEY 1/2 1/2 2 1-1/2 CHAPTER 6 NSF 61 UPC APPENDIXA IAPMO INSTALLATION STANDARDS 1.0 PER W.S.E.0 SEE INSULATION SCHEDULE NO INSERTS AT HANGERS USE INSERTS AT CLAMPS INSERTS TO BE STYRENE PIPE IDENTIFICATION MARKER WHITE LETTERING ON GREEN BACKGROUND � OPERATING PRESSURE UP TO 100 PSI; SET RELIEF TO XXX PSI OR APPROVED ALTERNATE SIZES THRU 2" PIPE MATERIAL COPPER TUBE TYPE L ASTM B88 PER SUBMITTAL NOTE: THE ABOVE DATA SHALL BE USED FOR PRELIMINARY ELECTRICAL, STRUCTURAL OR ARCHITECTURAL COORDINATION ONLY. USE APPROVED MANUFACTURER'S SUBMITTAL DATA FOR CONSTRUCTION. SPP = SIZE PER PLANS. JOINTS SWEAT: WATER BASED FLUXASTM B813; LEAD FREE SOLDER ASTM B-321 LEGAL DESCRIPTION LOT 8 (PER BOUNDARY LINE ADJUSTMENT NO. L02-057, AUDITOR'S FILE NO. 20030327900003, RECORDS OF KING COUNTY, WASHINGTON) THAT PORTION OF GOVERNMENT LOT 15 AND THE SOUTHWEST QUARTER OF THE SOUTHWEST QUARTER, SECTION 10 AND THE SOUTHEAST QUARTER, SECTION 9, ALL IN TOWNSHIP 23 NORTH, RANGE 4 EAST, W.M., IN KING COUNTY, WASHINGTON, DESCRIBED AS FOLLOWS: COMMENCING AT THE WEST ONE-QUARTER CORNER OF SAID SECTION 10; THENCE SOUTH 01 046'02" WEST ALONG THE WEST LINE THEREOF A DISTANCE OF 107.22 FEET TO A POINT ON SAID LINE; THENCE LEAVING SAID LINE SOUTH 87033'12" EAST A DISTANCE OF 512.24 FEET; THENCE SOUTH 01 046'02" WEST A DISTANCE OF 402.93 FEET; THENCE NORTH 88°13'58" WEST A DISTANCE OF 616.22 FEET; THENCE SOUTH 32009'15" EAST A DISTANCE OF 26.64 FEET; THENCE SOUTH 22°04'16" EAST A DISTANCE OF 220.58 FEET TO A POINT ON THE WEST LINE OF SAID GOVERNMENT LOT 15; THENCE LEAVING SAID WEST LINE SOUTH 20030'45" EAST A DISTANCE OF 471.28 FEET; THENCE SOI ITH 01'46'02" WEST A DISTANCE OF 433.06 FEET TO THE TRUE POINT OF BEGINNING; THENCE CONTINUING SOUTH 01 °46'02" WEST A DISTANCE OF 129.92 FEET; THENCE SOUTH 88013'58" EAST A DISTANCE OF 321.41 FEET; THENCE SOUTH 01 046'02" WEST A DISTANCE OF 367.67 FEET TO THE NORTH MARGIN OF SOUTH 126TH STREET; THENCE NORTH 89°18'50" WEST ALONG SAID MARGIN A DISTANCE OF 100.03 FEET; THENCE SOUTH 01 046'02" WEST A DISTANCE OF 10.00 FEET; THENCE NORTH 89018'50" WEST A DISTANCE OF 20.00 FEET TO THE WESTERLY MARGIN OF 34TH AVENUE SOUTH; THENCE SOUTH 01 °47'05" WEST ALONG SAID WEST MARGIN A DISTANCE OF 244.07 FEET TO THE SOUTHEAST CORNER OF LOT C OF BOUNDARY LINE ADJUSTMENT NO.89-6-BLA, RECORDED UNDER KING COUNTY RECORDING NO. 8908161260; THENCE NORTH 88048'42" WEST ALONG THE SOUTH LINE THEREOF A DISTANCE OF 277.34 FEET TO THE EAST MARGIN OF PRIMARY STATE HIGHWAY NO. 1, SR 99, PACIFIC HIGHWAY SOUTH, SAID POINT BEING ON A NON -RADIAL 1860.00 FOOT -RADIUS CURVE CONCAVE TO THE EAST AND FROM WHICH THE RADIUS POINT BEARS NORTH 73°28'18" EAST; THENCE NORTHERLY ALONG SAID MARGIN AND SAID CURVE AN ARC DISTANCE OF 134.53 FEET THROUGH A CENTRAL ANGLE OF 04008'39" TO THE POINT OF TANGENCY; THENCE CONTINUING ALONG SAID EAST MARGIN NORTH 12023'03" WEST A DISTANCE OF 294.34 FEET TO AN ANGLE POINT ON SAID MARGIN; THENCE CONTINUING ALONG SAID EAST MARGIN NORTH 07°52'07" WEST A DISTANCE OF 229.45 FEET; THENCE LEAVING SAID EAST MARGIN SOUTH 89018'15" EAST A DISTANCE OF 252.04 FEET TO THE POINT OF BEGINNING. SITUATED IN THE CITY OF TUKWILA, COUNTY OF KING, STATE OF WASHINGTON. LOCATION /VICINITY MAP PLUMBING SPECIFICATION (WSEC); LATEST REVISION: 6/11/2015 PRESSURE TEST PROCEDURE SEISMIC INSULATION ID CATEGORY SERVICE DESCRIPTION MANUFACTURER, PRODUCT OR EQUAL MEDIA TEST PRESSURE DURATION CODE IMPORTANCE IP & JACKETING CW & HW HWC (POTABLE) COLD WATER (DOMESTIC) DOMESTIC HOT AND COLD WATER SERVICE HOT WATER to 160 DEG F(DOMESTIC) COMPLY WITH NSF -61 AND NSF 372 HOT WATER CIRCULATION TO 160 DEG F. AIR OR WATER 100% OF OPERATING PRESSURE 15 MINUTES OR MFG SPEC CHAPTER 6 NSF 61 UPC APPENDIXA IAPMO INSTALLATION STANDARDS 1.0 PER W.S.E.0 SEE INSULATION SCHEDULE NO INSERTS AT HANGERS USE INSERTS AT CLAMPS INSERTS TO BE STYRENE PIPE IDENTIFICATION MARKER WHITE LETTERING ON GREEN BACKGROUND � OPERATING PRESSURE UP TO 100 PSI; SET RELIEF TO XXX PSI REFER TO STRUCTURAL INFO FOR ADDITIONAL DETAILS.., �,� �.e r - ,+tt UIYiO�iIS^^ �, . -0 - POv;.ti C�,s�ii '�r€Li� C SIZES THRU 2" PIPE MATERIAL COPPER TUBE TYPE L ASTM B88 PER SUBMITTAL JOINTS PRESS-FIT MECHANICAL COMPRESSION - THREADED AT SPECIALTIES JOINTS SWEAT: WATER BASED FLUXASTM B813; LEAD FREE SOLDER ASTM B-321 JOINTS SILVER BRAZED: PER UPC CHAPTER 6 COUPLINGS COPPER -LEAD FREE- PRESS FIT MECHANICAL COMPRESSION - ASME B16.1 / 16.22 VIEGA PROPRESS; EPDM SEAL (BLACK) FITTINGS COPPER -LEAD FREE- PRESS FIT MECHANICAL COMPRESSION - ASME B16.1 / 16.22 VIEGA PROPRESS; EPDM SEAL (BLACK) FITTINGS CAST BRONZE -SWEAT- ASTM B584 - LEAD FREE - NSF 61 VALVES - ISOLATION PRESS FIT LEAD FREE BRONZE BALL VALVE -FULL PORT -1/4 TURN - NSF 61G & 372 APOLLO 77VLF-100; VIEGA PROPRESS-2971 VALVES - ISOLATION (ALT) SWEAT - LEAD FREE 2 -PC BRONZE BALL VALVE -FULL PORT- 1/4 TURN - NSF 61G & 372 APOLLO 77CLF-200; MILWAUKEE BA -4856 V SANITARY VENT - ABOVE GROUND CAST IRON SANITARY VENT WATER WATER 10 FT HEAD FILL SYSTEM FROM LOWEST TO HIGHEST POINT OF TEST SECTION VISUAL INSPECTION WITH NO LEAKS UPC CHAPTER 9 1.0 N/A PIPE IDENTIFICATION MARKER WHITE LETTERING ON GREEN BACKGROUND OPERATING PRESSURE UP TO 5 PSI ALL SIZES (1) PIPE MATERIAL CAST IRON NO -HUB ASTM A 888 & CISPI 301 PER SUBMITTAL JOINTS NHCI COUPLINGS - STANDARD - CISPI 310 & ASTM C 1277 PER SUBMITTAL FITTINGS CAST IRON DRAIN PATTERNS CISPI 301 PER SUBMITTAL BALANCING REPORT (PER 2012 WASHINGTON STATE ENERGY CODE SECTION W SANITARY WASTE - ABOVE GROUND CAST IRON SANITARY WASTE WATER WATER 10 FT HEAD FILL SYSTEM FROM LOWEST TO HIGHEST POINT OF TEST SECTION VISUAL INSPECTION LEAKS WITH UPC CHAPTER 7 1.0 N/A PIPE IDENTIFICATION MARKER WHITE LETTERING ON GREEN BACKGROUND OPERATING PRESSURE UP TO 5 PSI ALL SIZES (1) PIPE MATERIAL CAST IRON NO -HUB ASTM A 888 AND CISPI 301 PER SUBMITTAL JOINTS NHCI COUPLINGS - STANDARD - CISPI 310 & ASTM C 1277 PER SUBMITTAL FITTINGS ICAST IRON DRAIN PATTERNS CISPI 301 PER SUBMITTAL NOTES: 1. MCKINSTRY DOES NOT INSTALL 5" DWV. 1/2" CW DN TO 3RD FLOOR. CONNECT TO (E) CW CONNECTION AT WATER FOUNTAIN ER ;i AERP LIP i 1, N1 ACER LEA lir. SERVER ROOM if� \,l xCz _ ♦! r r- 2 WASTE ROUTED DN TO 3RD FLOOR CEILING. SCANNING REQUIRED PRIOR TO CORING THROUGH DECK. ��� I 3 \_// ADP R T I RCM I "i - -� I I�S14 R s l I 3 STOR GE1 � L-,/ WOMEN I tj 13 i II. ID P e . L U1R`' ° 0 w!l g ( u, A i : f i I . CORRIDOR €4 NEW 1.4 KW MINI TANK WATER HEATER W/ =77 7_7_7 T&P VALVE. LOCATED BELOW SINK. -_---- - -- --=='' EEMAX EMT -4 OR EQUIVALENT. SEE SUBMITTAL FOR INSTALLATION DETAILS. �-f f 1-1/2" VENT CONNECTION TO EXISTING VENT �f ti -ii RISER. FIELD TO COORDINATE TIE-IN POINT. ....�.... COMPUTER i E L EV.--=-' ___ _ I; STORAGE . 1 3 12 WASTE CONNECTION TO EXISTING 4: `WASTE RISER. FIELD TO COORDINATE TIE-IN POINT ON 3RD FLOOR. EI�. . i ' ELEV. I I j`j �j Ii PUBLIC CORRIDOR 11 00 FLOOR PLUMBING PLAN rF'� SCALE: 1/8"= V-0" !!Nklq-, 66) SCOPE OF WORK PROVIDE (1) NEW SINK WITH POINT OF USE ELECTRIC WATER HEATER. 120V PLUG IN BELOW SINK. CONNECT TO EXISTING 1/2" CW LOCATED ON 3RD FLOOR. FIELD TO COORDINATE FINAL SCANNING/CORING OF PT DECK AND POINT OF CONNECTION WITH G.C. WASTE CONNECTED TO EXISTING 4" RESTROOM WASTE LINES IN 3RD FLOOR CEILING. COORDINATE WITH G.C. FOR SCANNING AND CORING THROUGH PT DECK. VENT CONNECTED TO EXISTING RESTROOM/JANITOR'S CLOSET VENT RISER, COORDINATE WITH G.C. FOR ACCESS THROUGH HARD LID CEILINGS. er s� w", www.mckinstry.com DEPARTMENT OF HOMELAND SECURITY TI GENERAL NOTES: 1. VERIFY LOCATIONS AND DIMENSIONS OF ALL EQUIPMENT AND COORDINATE ALL trov scope WORK PRIOR TO START OF CONSTRUCTION. REGISTRATION: isan. 2. OBTAIN APPROVAL OF STRUCTURAL ENGINEER PRIOR TO INSTALLATION OF QTS! Su m,ttal PENETRATIONS NOT PREVIOUSLY COORDINATED OR AGREED UPON, I.E. HLE DUCTWORK AND PIPING SPECIFICATION MATRICES CONTAINED WITHIN THIS ANCHOR BOLT DEPTHS, ETC. vg ��gENCg 3. CONCRETE EQUIPMENT CURBS, PIPING RAT SLABS, SUMP BASINS, AND Fer e O. �°gWt►s r c HOUSEKEEPING PADS ARE SHOWN FOR APPROXIMATE LOCATION AND SIZE AND CONNECTION OF EQUIPMENT FURNISHED BY THE OWNER OR OTHERS. ARE TO BE PROVIDED BY THE GENERAL CONTRACTOR. WHERE PRO €D '�� ; oip`,m -1 iS subied f0 errors �D� � � '• � - � REFER TO STRUCTURAL INFO FOR ADDITIONAL DETAILS.., �,� �.e r - ,+tt UIYiO�iIS^^ �, . -0 - POv;.ti C�,s�ii '�r€Li� C STRUCTURAL INFORMATION (WHERE PROVIDED) AND PROJECT SPECIFIC 4. COMPLETION AND COMMISSIONING FOR MECHANICAL SYSTEMS: the �JfOlB�.a _, Otl;+ a*Dw ed o0d0GISTE�� 47808 ' SSIO � 7 �G Ni1L ` �{ '��('� Q ��¢g Rf�/ tea :-iEIO iJ� LL �• n:-::.0 3J ,3 Y.w'.fl��iEY.od: : u PER WASHINGTON STATE ENER' RS A. COMPLETE SYSTEM COMMISSIONING SECTION 0408.1. PROVIDE A COMMISSIONING PLAN, PRELIMINARY AND FINAL tis.• I COMMISSIONING REPORTS TO THE OWNER PER C408.1.1, C408.1.2 AND I C408.1.3.4. Date: B. PROVIDE RECORD DRAWINGS OF THE ACTUAL INSTALLATION TO THE., City of ? ukwilla OWNER(PER 2012 WASHINGTON STATE ENERGY CODE SECTION C408.1.3.1) BUILDING DIVISION C. PROVIDE TO THE OWNER ALL NECESSARY SYSTEMS DOCUMENTATION (PER ISSUES: 2012 WASHINGTON STATE ENERGY CODE SECTION C408.1.3.2) 3/18/16 PLUMBING PERMIT D. BALANCE ALL HVAC SYSTEMS AND PROVIDE TO THE OWNER A WRITTEN BALANCING REPORT (PER 2012 WASHINGTON STATE ENERGY CODE SECTION 04081 VAI E. SYSTEMS/EQUIPMENT/CONTROLS FUNCTIONAL TESTING SHALL BE PERFORMED REVIsms IN ACCORDANCE WITH APPROVED PLANS (PER 2012 WASHINGTON STATE ICU Changes shaij ha rde r, ENERGY CODE SECTION C408.2.2 AND C408.2.3). Of work w ti1C-, r 0riOr 2 ; F. PERFORMANCE OF ALL NEW BUILDING MECHANICAL SYSTEMS WILL COMPLY ' I ",'it I.1 srn ^ '^ WITH OR EXCEED THE MINIMUM REQUIREMENTS AS SET FORTH IN THE 2012 `�� I I ' ` r��.---i -• r, WASHINGTON STATE ENERGY CODE CHAPTER 3 - GENERAL REQUIREMENTS. ---------------- 5. MINIMUM VENTILATION QUANTITIES WILL COMPLY WITH OR EXCEED THE 2012 - INTERNATIONAL MECHANICAL CODE. 6. ALL MOTORS WILL COMPLY WITH CHAPTER 4 OF THE 2012 WASHINGTON STATE ENERGY CODE. FOR ADDITIONAL DETAILS, SEE EQUIPMENT SCHEDULES trov scope larical isan. QTS! Su m,ttal Ej Plumbing DUCTWORK AND PIPING SPECIFICATION MATRICES CONTAINED WITHIN THIS p1pinu DRAWING SET. as 8. VERIFY THAT ALL NECESSARY INFORMATION HAS BEEN PROVIDED PRIOR TO Cys of u .,vi a CONNECTION OF EQUIPMENT FURNISHED BY THE OWNER OR OTHERS. 6. ALL MOTORS WILL COMPLY WITH CHAPTER 4 OF THE 2012 WASHINGTON STATE ENERGY CODE. FOR ADDITIONAL DETAILS, SEE EQUIPMENT SCHEDULES CONTAINED WITHIN THIS DRAWING SET. 7. ALL SYSTEMS WILL BE INSULATED AS PRESCRIBED IN C403.2.7 AND C403.2.8 OF THE 2012 WASHINGTON STATE ENERGY CODE. FOR ADDITIONAL DETAILS, SEE DUCTWORK AND PIPING SPECIFICATION MATRICES CONTAINED WITHIN THIS NO. DATE DESCRIPTION DRAWING SET. 8. VERIFY THAT ALL NECESSARY INFORMATION HAS BEEN PROVIDED PRIOR TO McKINSTRY DIVISION: CONNECTION OF EQUIPMENT FURNISHED BY THE OWNER OR OTHERS. ENGINEERING 9. FOR ADDITIONAL SYSTEM AND EQUIPMENT SEISMIC REQUIREMENTS, REFER TO STRUCTURAL INFORMATION (WHERE PROVIDED) AND PROJECT SPECIFIC SEISMIC DESIGN INFORMATION SHEET CONTAINED WITHIN THIS DRAWING SET. DESIGNED BY: AS Anr♦ nr utnov KEY PLAN NOT TO SCALE REVIEV`VED FOR - CODE COMPLIANCE APPROVED MAR 2 5 2015 City O 1u?viila BUILDING DIVISION DRAWN BY: LC/AS CHECKED BY: AS JOB NUMBER: DATE: 02/19/16 SCALE: AS SHOWN RECEIVED CITY OF TUKWILA SHEET TITLE: MAR 18 2016 4TH FLOOR PERMIT CENTER PLUMBING PLAN SHEET NUMBER: +