HomeMy WebLinkAboutPermit PG16-0045 - PEARLE VISION - ELECTRIC HOT WATER HEATER AND DRINKING FOUNTAINPEARLE VISION
17250 SOUTHCENTER PKWY
SUITE 128
PG16-0045
4
City of Tukwila
Department of Community Development
• 6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206-431-3670
Inspection Request Line: 206-438-9350
Web site: http://www.TukwilaWA.gov
PLUMBING/GAS PIPING PERMIT
Parcel No: 7888920020 Permit Number: PG16-0045
Address: 17250 SOUTHCENTER PKWY 128 Issue Date: 5/23/2016
Permit Expires On: 12/7/2016
Project Name: PEARLE VISION
Owner:
2012
Name:
WIG PROPERTIES LLC -SS
Address:
4811 134TH PL SE , BELLEVUE, MN,
WA Cities Electrical Code:
98006
Contact Person:
2012
Name:
TIM SCHENK
Address:
1120 E 80 ST #211, BLOOMINGTON,
WA State Energy Code:
MN, 55420
Contractor:
2012
Name:
LAKEVIEW CONSTRUCTION INC
Address:
10505 CORPORATE DR #200,
PLEASANT PRAIRIE, WI, 53158
License No:
LAKEVC1072KC
Lender:
Name:
Phone: (952) 345-6040
Phone: (414) 657-4222
Expiration Date: 1/13/2017
Address: , , ,
DESCRIPTION OF WORK:
NEW ELECTRIC HOT WATER HEATER, RELOCATE EXISTING HI/LO DRINKING FOUNTAIN. 3 NEW HAND SINKS, 1
NEW EMPLOYEE BREAKROOM SINK
Valuation of Work: $15,000.00 Fees Collected: $235.96
Water District: TUKWILA
Sewer District: TUKWILA
Current Codes adopted by the City of Tukwila:
International Building Code Edition:
2012
National Electrical Code:
2014
International Residential Code Edition:
2012
WA Cities Electrical Code:
2014
International Mechanical Code Edition:
2012
WAC 296-4613:
2014
Uniform Plumbing Code Edition:
2012
WA State Energy Code:
2012
International Fuel Gas Code:
2012
Permit Center Authorized Signatu
c
Date: 6 , (4' �
I hearby certify that I have read and examined this permit and know the same to be true and correct. All
provisions of law and ordinances governing this work will be complied with, whether specified herein or not.
The granting of this permit does not presume to give authority to vio to or cancel the provisions of any other
state or local laws regulating construction or the performanc rk. I am authorized to sign and obtain this
development per nd agre to the c tions attac his permit.
Signatur ✓ Date:
This permit shall become null and void if the work is not commenced within 180 days for the date of issuance, or if
the work is suspended or abandoned for a period of 180 days from the last inspection.
PERMIT CONDITIONS:
1: ***PLUMBING/GAS PIPING PERMIT CONDITIONS***
2: No changes shall be made to applicable plans and specifications unless prior approval is obtained from the
Tukwila Building Division.
3: All permits, inspection records and applicable plans shall be maintained at the job and available to the
plumbing inspector.
4: All plumbing and gas piping systems shall be installed in compliance with the Uniform Plumbing Code and
the Fuel Gas Code.
5: No portion of any plumbing system or gas piping shall be concealed until inspected and approved.
6: All plumbing and gas piping systems shall be tested and approved as required by the Plumbing Code and
Fuel Gas Code. Tests shall be conducted in the presence of the Plumbing Inspector. It shall be the duty of
the holder of the permit to make sure that the work will stand the test prescribed before giving notification
that the work is ready for inspection.
7: No water, soil, or waste pipe shall be installed or permitted outside of a building or in an exterior wall
unless, adequate provision is made to protect such pipe from freezing. All hot and cold water pipes
installed outside the conditioned space shall be insulated to minimum R-3.
8: Plastic and copper piping running through framing members to within one (1) inch of the exposed framing
shall be protected by steel nail plates not less than 18 guage.
9: Piping through concrete or masonry walls shall not be subject to any load from building construction. No
plumbing piping shall be directly embedded in concrete or masonry.
10: All pipes penetrating floor/ceiling assemblies and fire -resistance rated walls or partitions shall be protected
in accordance with the requirements of the building code.
11: Piping in the ground shall be laid on a firm bed for its entire length. Trenches shall be backfilled in thin
layers to twelve inches above the top of the piping with clean earth, which shall not contain stones,
boulders, cinderfill, frozen earth, or construction debris.
12: The issuance of a permit or approval of plans and specifications shall not be construed to be a permit for, or
an approval of, any violation of any of the provisions of the Plumbing Code or Fuel Gas Code or any other
ordinance of the jurisdiction.
13: The applicant agrees that he or she will hire a licensed plumber to perform the work outlined in this permit.
14: All new plumbing fixtures installed in new construction and all remodeling involving replacement of
plumbing fixtures in all residential, hotel, motel, school, industrial, commercial use or other occupancies
that use significant quantities of water shall comply with Washington States Water Efficiency ad
Conservation Standards in accordance with RCW 19.27.170 and the 2006 Uniform Plumbing Code Section
402 of Washington State Amendments
15: ***PUBLIC WORKS PERMIT CONDITIONS***
16: BEFORE PERMIT CAN BE ISSUED THE APPLICANT SHALL SUBMIT King County Non -Residential SEWER USE
CERTIFICATION FORM AND LIST ALL THE NEW PLUMBING FIXTURES TO BE INSTALLED. DO NOT LIST
FIXTURES TO BE REPLACED IN KIND.
PERMIT INSPECTIONS REQUIRED
Permit Inspection Line: (206) 438-9350
8004 GROUNDWORK
1900 PLUMBING FINAL
8005 ROUGH -IN PLUMBING
City of Tukwila
• ' Department of Community Development
• 6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206-431-3670
Inspection Request Line: 206-438-9350
Web site: http://www.TukwilaWA.Rov
PLUMBING/GAS PIPING PERMIT
Parcel No: 7888920020 Permit Number: PG16-0045
Address: 17100 SOUTHCENTER PKWY 128 Issue Date: 5/23/2016
Permit Expires On: 11/19/2016
Project Name: PEARLE VISION
Owner:
2012
National Electrical Code:
Name:
WIG PROPERTIES LLC -SS
2012
Address:
4811 134TH PL SE, BELLEVUE, MN,
International Mechanical Code Edition:
2012
98006
2014
Contact Person:
2012
WA State Energy Code:
Name:
TIM SCHENK
Phone: (952) 345-6040
Address:
1120 E 80 ST #211, BLOOMINGTON,
MN, 55420
Contractor:
Name:
LAKEVIEW CONSTRUCTION INC
Phone: (414) 657-4222
Address:
10505 CORPORATE DR #200,
PLEASANT PRAIRIE, WI, 53158
License No:
LAKEVC1072KC
Expiration Date: 1/13/2017
Lender:
Name:
Address:
DESCRIPTION OF WORK:
NEW ELECTRIC HOT WATER HEATER, RELOCATE EXISTING HI/LO DRINKING FOUNTAIN. 3 NEW HAND SINKS, 1
NEW EMPLOYEE BREAKROOM SINK
Valuation of Work: $15,000.00
Water District: TUKWILA
Sewer District: TUKWILA
Fees Collected: $235.96
Current Codes adopted by the City of Tukwila:
International Building Code Edition:
2012
National Electrical Code:
2014
International Residential Code Edition:
2012
WA Cities Electrical Code:
2014
International Mechanical Code Edition:
2012
WAC 296-466:
2014
Uniform Plumbing Code Edition:
2012
WA State Energy Code:
2012
International Fuel Gas Code:
2012
Permit Center Authorized Signature: I A / M Date: J ��' v/
I hearby certify that I have read and examined this permit and know the same to be true and correct. All
provisions of law and ordinances governing this work will be complied with, whether specified herein or not.
The granting of this permit does not presume to give authority to violate or cancel the provisions of any other
state or local laws re lating constr or r or nce of work. I am authorized to sign and obtain this
development pe,. it and agre fe. o the ition ached to this permit.
Signatur Date:
Prin arae: ,is .0
This permit shall become null and void if the work is not commenced within 180 days for the date of issuance, or if
the work is suspended or abandoned for a period of 180 days from the last inspection.
PERMIT CONDITIONS:
1: ***PLUMBING/GAS PIPING PERMIT CONDITIONS***
2: No changes shall be made to applicable plans and specifications unless prior approval is obtained from the
Tukwila Building Division.
3: All permits, inspection records and applicable plans shall be maintained at the job and available to the
plumbing inspector.
4: All plumbing and gas piping systems shall be installed in compliance with the Uniform Plumbing Code and
the Fuel Gas Code.
5: No portion of any plumbing system or gas piping shall be concealed until inspected and approved.
6: All plumbing and gas piping systems shall be tested and approved as required by the Plumbing Code and
Fuel Gas Code. Tests shall be conducted in the presence of the Plumbing Inspector. It shall be the duty of
the holder of the permit to make sure that the work will stand the test prescribed before giving notification
that the work is ready for inspection.
7: No water, soil, or waste pipe shall be installed or permitted outside of a building or in an exterior wall
unless, adequate provision is made to protect such pipe from freezing. All hot and cold water pipes
installed outside the conditioned space shall be insulated to minimum R-3.
8: Plastic and copper piping running through framing members to within one (1) inch of the exposed framing
shall be protected by steel nail plates not less than 18 guage.
9: Piping through concrete or masonry walls shall not be subject to any load from building construction. No
plumbing piping shall be directly embedded in concrete or masonry.
10: All pipes penetrating floor/ceiling assemblies and fire -resistance rated walls or partitions shall be protected
in accordance with the requirements of the building code.
11: Piping in the ground shall be laid on a firm bed for its entire length. Trenches shall be backfilled in thin
layers to twelve inches above the top of the piping with clean earth, which shall not contain stones,
boulders, cinderfill, frozen earth, or construction debris.
12: The issuance of a permit or approval of plans and specifications shall not be construed to be a permit for, or
an approval of, any violation of any of the provisions of the Plumbing Code or Fuel Gas Code or any other
ordinance of the jurisdiction.
13: The applicant agrees that he or she will hire a licensed plumber to perform the work outlined in this permit.
14: All new plumbing fixtures installed in new construction and all remodeling involving replacement of
plumbing fixtures in all residential, hotel, motel, school, industrial, commercial use or other occupancies
that use significant quantities of water shall comply with Washington States Water Efficiency ad
Conservation Standards in accordance with RCW 19.27.170 and the 2006 Uniform Plumbing Code Section
402 of Washington State Amendments
15: ***PUBLIC WORKS PERMIT CONDITIONS***
16: BEFORE PERMIT CAN BE ISSUED THE APPLICANT SHALL SUBMIT King County Non -Residential SEWER USE
CERTIFICATION FORM AND LIST ALL THE NEW PLUMBING FIXTURES TO BE INSTALLED. DO NOT LIST
FIXTURES TO BE REPLACED IN KIND.
PERMIT INSPECTIONS REQUIRED
Permit Inspection Line: (206) 438-9350
8004 GROUNDWORK
1900 PLUMBING FINAL
8005 ROUGH -IN PLUMBING
CITY OF TUKWi_ ,
Community Development Department
Permit Center
• 6300 Southcenter Blvd., Suite 100
Tukwila, WA 98188
http://www.Tukwi]aWA.p-ov
SITE LOCATION
Plumbing/Gas Permit No. i5"Ovys
Project No.
Date Application Accepted:
Date Application Expires:
use
PLUMBING / GAS PIPING PERMIT APPLICATION
Applications and plans must be complete in order to be accepted for plan review.
Applications will not be accepted through the mail or by fax.
"Please Print"
Site Address: 17100 Southcenter Parkway
Tenant Name: Pearle Vision
PROPERTY OWNER
Name: WIG Properties, LLC
Address: 4811 134th. Place S.E.
City: Bellevue State: WA Zip: 98006
CONTACT PERSON — person receiving all project
communication
Name: Tim Schenk
Address: 1120 E. 80th. Street, Suite 211
City: Bloomington State: MN Zip: 55420
Phone: (952) 345-6040 Fax: (952) 854-4909
Email: tiros@elderjones.com
Valuation of Project (contractor's bid price): $ 15,000
King Co Assessor's Tax No.: 7888920020
Suite Number: 128
New Tenant:
Floor: 1
® .....Yes ❑ ..No
PLUMBING CONTRACTOR INFORMATION
Company Name: T.B.D.
Address:
City: State: Zip:
Phone: Fax:
Contr Reg NO.: Exp Date:
Tukwila Business License No.:
Scope of Work (please provide detailed information):
New electric hot water heater, relocate existing Hi / Lo drinking fountain. 3 new hand sinks, 1 new employee breakroom sink
Building Use (per Int'l Building Code):
Occupancy (per Int'l Building Code):
Utility Purveyor: Water:
M
Retail Sales
Tukwila Sewer: Tukwila
H:lApplications\Fomts-Applications On Line\2011 ApplicationsTlumbing Permit Application Revised 8-9.11.docx
Revised: August 2011 Page 1 of 2
bh
' Indicarte type of plumbing fixtures and/or bas piping outlets being installed and the quantity below:
Fixture Type
Qty
Bathtub or combination
bath/shower
2
Dishwasher, domestic with
independent drain
Shower, single head trap
Sinks
4
Rain water system — per
drain (inside building)
Grease interceptor for
commercial kitchen (>750
gallon capacity)
Each additional medical
gas inlets/outlets greater
than 5
Atmospheric -type vacuum
breakers not included in
lawn sprinkler backflow
protections I=5)
Fixture Type
Qty
Bidet
Drinking fountain or water
2
cooler (per head)
Lavatory
Urinal
Water heater and/or vent
1
Repair or alteration of
water piping and/or water
treatment equipment
Backflow protective device
other than atmospheric -
type vacuum breakers 2
inch (5) mm) diameter or
smaller
Atmospheric -type vacuum
breakers not included in
lawn sprinkler backflow
protections over 5
PERMIT APPLICATION NOTES -
Fixture Type
Qty
Clothes washer,
domestic
Food -waste grinder,
commercial
Wash fountain
Water closet
Industrial waste
treatment interceptor,
including trap and vent,
except for kitchen type
grease interceptors
Repair or alteration of
drainage or vent piping
Backflow protective
device other than
atmospheric -type
vacuum breakers over 2
inch (51 mm) diameter
Gas piping outlets
Fixture Type
Qty
Dental unit, cuspidor
Floor drain
Receptor, indirect waste
Building sewer and each
trailer park sewer
Each grease trap
(connected to not more
than 4 fixtures - <750
gallon capacity
Medical gas piping
system serving 1-5
inlets/outlets for a specific
as
Each lawn sprinkler
system on any one meter
including backflow
protection devices
Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject
to possible revision by the Permit Center to comply with current fee schedules.
Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation.
The Building Official may grant one extension of time for an additional period not to exceed 180 days. The extension shall be requested in writing
and justifiable cause demonstrated. Section 103.4.3 International Plumbing Code (current edition).
I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER
PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT.
BUILDING OWNER OR AUTHORIZED AGENT:
Date: 03/28/2016
Print Name: Tim Schenk Day Telephone: (952) 345-6040
Mailing Address: 1120 E. 80th. Street, Suite 211 Bloomington MN 55420
City State Zip
HAApplicationsTorms-Applications On Linc\2011 ApplicationsTlumbing Pcrmit Application Reviscd 8.9-1I.docx
Revised: August 2011
bh Page 2 of 2
DESCRIPTIONS QUANTITY
PermitTRAK
PAID
$2,444.46
D16-0085 Address: 17100 SOUTHCENTER PKWY 128 Apn: 7888920020
$2,011.16
DEVELOPMENT
$1,915.60
PERMIT FEE R000.322.100.00.00
0.00
$1,911.10
WASHINGTON STATE SURCHARGE 8640.237.114
0.00
$4.50
TECHNOLOGY FEE
$95.56
TECHNOLOGY FEE R000.322.900.04.00
0.00
$95.56
M16-0048 Address: 17100 SOUTHCENTER PKWY 128 Apn: 7888920020
$346.34
MECHANICAL
$329.85
PERMIT ISSUANCE BASE FEE R000.322.100.00.00
0.00
$32.50
PERMIT FEE R000.322.100.00.00
0.00
$297.35
TECHNOLOGY FEE
$16.49
TECHNOLOGY FEE R000.322.900.04.00
0.00
$16.49
PG16-0045 Address: 17100 SOUTHCENTER PKWY 128 Apn: 7888920020
$86.96
PLUMBING
$77.88
PERMIT ISSUANCE BASE FEE R000.322.100.00.00
0.00
$32.50
PLAN CHECK FEE R000.322.103.00.00
0.00
$45.38
TECHNOLOGY FEE
$9.08
TECHNOLOGY FEE R000.322.900.04.00
TOTAL
0.00
$9.08
i .46
Date Paid: Monday, May 23, 2016
Paid By: LAKEVIEW CONSTRUCTION INC
Pay Method: CHECK 43516
Printed: Monday, May 23, 2016 7:40 AM 1 of 1 C_'r[`(,:,1 SYSTEMS
DESCRIPTIONS ACCOUNT QUANTITY
PermitTRAK
PAID
$2,037.85
D16-0085 Address: 17100 SOUTHCENTER PKWY 128 Apn: 7888920020
$1,242.22
DEVELOPMENT
$1,242.22
PLAN CHECK FEE R000.345.830.00.00
0.00
$1,242.22
EL16-0275 Address: 17100 SOUTHCENTER PKWY 128 Apn: 7888920020
$564.17
ELECTRICAL
$537.30
PERMIT FEE MULTI-FAM/COMM R000.322.101.00.00
0.00
$537.30
TECHNOLOGY FEE
$26.87
TECHNOLOGY FEE R000.322.900.04.00
0.00
$26.87
M16-0048 Address: 17100 SOUTHCENTER PKWY 128 Apn: 7888920020
$82.46
MECHANICAL
$82.46
PLAN CHECK FEE R000.322.102.00.00
0.00
$82.46
PG16-0045 Address: 17100 SOUTHCENTER PKWY 128 Apn: 7888920020
$149.00
PLUMBING
$149.00
PERMIT FEE R000.322.100.00.00
TOTALPAID :1 •
0.00
$149.00
$2,037.8S
Date Paid: Tuesday, March 29, 2016
Paid By: ELDER -JONES
Pay Method: CHECK 74015
Printed: Tuesday, March 29, 2016 2:36 PM 1 of 1
RWSY57EM5
SINSPECTION RE
Retain a copy with
IRVECTION NO.
-ORD ---��
permit
PERMIT N0.
CITY OF TUKWILA BUILDING DIVISION
6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-367 '41
Permit Inspection Request Line (206) 438-9350
Proj /
Ie1,� /S lO�l
Type of Inspection:
1 IAIAt—
Address:
1725'o e6jr PZj
Date Called:
Special Instructions:
Date Wanted:,.
Requester:
Phone No:
0Approved per applicable codes. LJ Corrections required prior to approval.
IInspector: /J .A A IDate: -7//q Ila
REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be
paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection.
INSPECTION RECORD
?/ Retain a copy with permit �% ' vD r
PECTION NO. PERMIT NO.
CITY OF TUKWILA BUILDING DIVISION
6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670
Permit Inspection Request Line (206) 438-9350
Pr ject: C (I
jrl V1d h
Type of Inspection::
IAV Lky /L °'. ✓�'I ttic
Address. Q c Q�
, d�
f ,
Date C fly
Special Instructions:
Date Wanted: ji a.m.
p.m.
Reques er:
Phone No:
Inspector:
Date:
REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be
paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection.
I INSPECTION RECORD
l Retain a copy with permit �`�� 00
ITS PECTION N0. PERMIT N0.
CITY OF TUKWILA BUILDING DIVISION
6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670
Permit Inspection Request Line (206) 438-9350
Pro'ct:
e� [ �'� s r 0 v►
Type of Inspection,
6-VVk ect;( wa
Address:
Date Called:
Special Instructions:
#
Date Wanted: a.m.
—�i�'1 % % p.m.
/V
Requester. —�'�
Vk ' �0
Pho a No: ^z -f) T®
Inspector: Date:
� to
REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be
paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection.
PERMIT COORD COPY
PLAN REVIEW/ROUTING SLIP
PERMIT NUMBER: PG16-0045
PROJECT NAME: PEARLE VISION
DATE: 04/01/16
SITE ADDRESS: 17100 SOUTHCENTER PKWY
X Original Plan Submittal
Response to Correction Letter #
Revision # before Permit Issued
Deferred Submittal #_ after Permit Issued
DEPARTME
NTS:
ENTS:
A- (-
Building Division Fire Prevention ❑ Planning Division ❑
rks Structural ❑
Public WoPermit Coordinator
PRELIMINARY REVIEW: DATE: 04/05/16
Not Applicable ❑ Structural Review Required ❑
(no approval/review required)
REVIEWER'S INITIALS: DATE:
APPROVALS OR CORRECTIONS: DUE DATE: 05/03/16
Approved ❑ Approved with Conditions
Corrections Required ❑
(corrections entered in Reviews)
Notation:
REVIEWER'S INITIALS:
Denied ❑
(ie: Zoning Issues)
DATE:
Permit Center Use Only
CORRECTION LETTER MAILED:
Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials:
12/18/2013
Date:
City of Tukwila
Department of Community Development
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206-431-3670
Web site: bq:UA,"�r.Tukwilal,�'A.gov
REVISION
SUBMITTAL
Revision submittals must be submitted in person at the Permit Center.
Revisions will not be accepted through the mail, fax, etc.
❑ Response to Incomplete Letter #
Plan Check/Permit Number: ) o
❑ Response to Correction Letter #
❑ Revision # after Permit is Issued
❑ Revision requested by a City Building Inspector or Plans Examiner
❑ Deferred Submittal #
Project Name: t.
Project Address:
Contact Person:y.v1i �V-0S0 ti Phone Number:
Summary of Revision:
RECEIVED
CITY OF WKWILA
JUN 14 2016
Sheet Number(s):
"Cloud" or highlight all areas of revision including date of revision
Received at the City of Tukwila Permit Center by:
Entered in TRAKiT on '- C
W:Termit CenterUemplatesTorms\Revision Submittal Form. doc
Revised: August 2015
LAKEVIEW CONSTRUCTION INr'
Home Espanol Contact
Safety & Health Claims & Insurance
Washington State Department of
Labor & Industries
LAKEVIEW CONSTRUCTION INC
Owner or tradesperson 10505 CORPORATE DR, #200
PLEASANT PRAIRIE, WI 53158
Principals 414-657-4222
MOON, KENT ALAN, PRESIDENT
SUNDAY, EUGENE R, PRESIDENT
(End: 01/10/2011)
Doing business as
LAKEVIEW CONSTRUCTION INC
Page 1 of 2
Search L&1 I t
A -'L Index Flelp My L&I
Workplace Rights Trades & Licensing
WA UBI No.
Business type
601 447 862
Corporation
Policy no.
Governing persons
5082945285
ADAMSON
Received by L&I
E
01/11/2016
DEWAYNE
EUGENE R SUNDAY;
KENT A MOON;
License
Verify the contractor's active registration / license / certification (depending on trade) and any past violations.
Construction Contractor
Active.
Meets current requirements.
License specialties
GENERAL
License no.
LAKEVC1072KC
Effective — expiration
05/03/1993— 01/13/2017
Bond
.._........._.
TRAVELERS CAS & STY CO OF AMER
$12,000.00
Bond account no.
400MJ9662
Received by L&I
Effective date
02/17/2006
04/23/2006
Expiration date
Until Canceled
Insurance
...........................
National Fire Ins of Hartford
$1,000,000.00
Policy no.
5082945285
Received by L&I
Effective date
01/11/2016
01/0112015
Expiration date
01/01/2017
Insurance history
https://secure.Ini.wa.gov/verify/Detail.aspx?UBI=601447862&LIC=LAKEVC1072KC&SAW= 5/23/2016
SANITARY PLUMBING FLAN
SCALE: 1/4" = 1'-0"
PLUM 13I NG 5YM13OL5 (ALL SYMBOLS SHOWN AKC NOT NECE55AKILY USED ON THE DRAWINGS)
ELBOW UP
QTY. rAN F.U.
EACH
SAN F.U.
TOTAL
C.W F.U.
EACH
WTR. DMD.
TOTAL
T*P RELIEF VALVE
O ELBOW DOWN
G.0
2.2
4.4
I
WALL CLEANOUT
TEE OUTLET UP
0.7
1.4
(E) SERVICE SINK - 55
®
FLOOR CLEANOUT
.. TEE OUTLET DOWN
3.0
(E) FLOOR DRAIN - FD 1
2 2.0
p
PLUMBING FIXTURES
UNION
51NK (5K4 f- 5K7)
4 2.0
8.0
1 2.0
POINT OF NEW CONNECTION
—�, BALL VALVE
I 1 0.5
TO EXISTING PIPING OR SYSTEM
----- COLD WATER PIPING (CW)
Cr—
DRAWING NOTE REFERENCE
----� HOT WATER PIPING (HW)
WSFU
WATER SUPPLY FIXTURE UNITS
SANITARY PIPING (SAN)
O/H
OVERHEAD
------------ SANITARY VENT PIPING (V)
DN
DOWN
I/2"
U/G
UNDERGROUND
El CAP ON END LINE
-
-
-
EX
EXISTING
PLUMIDING CALCULATIONS
PLUMBING FIXTURE
QTY. rAN F.U.
EACH
SAN F.U.
TOTAL
C.W F.U.
EACH
WTR. DMD.
TOTAL
(E) W.C. (PRESSURE ASSIST)
2 3.0
G.0
2.2
4.4
(E) LAVATORY - 5K5
2 1.0
2.0
0.7
1.4
(E) SERVICE SINK - 55
1 3.0
3.0
3.0
3.0
(E) FLOOR DRAIN - FD 1
2 2.0
4.0
0.0
0.0
51NK (5K4 f- 5K7)
4 2.0
8.0
1 2.0
8.0
(R) ELECTRIC WATER COOLER (EWC2)
I 1 0.5
0.5
1 0.25
0.25
TOTALS 23.5 17.05
SERVICE CONNECTION 51ZE SAN. 4" WATER 1"
PLUMBING FIXTURE
CONNECTION 5CHEDULE
FIXTURE
DRAIN
HOT
COLD
VENT
SINK (5 K4 SK
2"
I/2"
I/2"
1 1/2"
FLOOR CLEAN OUT CO
PIPE SIZE
-
-
-
WALL CLEAN OUT WC
PIPE 51ZE
-
-
-
ELECTRIC WATER HEATER
1
3/4
3/4
-
ELECTRIC WATER COOLER EWC
1 112"
-
112"
1 112"
NOTE:(SKI THRU 4) CONTRACTOR WILL BE REQUIRED TO FURNISH ALL LABOR, PIPING MATERIALS
AND APPURTENANCES NECESSARY TO COMPLETE INSTALLATION OF SINKS, FAUCETS AND DRAINS
FURNISHED BY TENANT.
PLAN NORTH
TRUE NORTH
KEY NOTES
MARK
DESCRIPTION
FIELD VERIFY EXACT CONDITIONS AND ROUTING OF WORK. CONTACT ENGINEER OR
CONNECT TO EXISTING 4" OR LARGER SANITARY AS REQUIRED. FIELD VERIFY EXACT
OI
SIZE, LOCATION, INVERT ELEVATION AND FLOW DIRECTION OF EXISTING SANITARY
EXISTING PLUMBING INFORMATION IS BASED ON LIMITED EXISTING BUILDING
PRIOR TO WORK.
OEXTEND
NEW 2" VENT TO EXISTING VENT MAIN. FIELD VERIFY EXACT SIZE AND
CONDITIONS FOR ACCURACY. NO ADDITIONAL_ COMPENSATION SHALL BE ALLOWED
LOCATION OF EXISTING VENT MAIN PRIOR TO START OF WORK. IF EXISTING VENT
FOR REVISIONS TO THE DESIGN TO CORRECT FOR EXISTING CONDITIONS NOT AS
MAIN IS NOT EXISTING, CONTRACTOR SHALL PROVIDE NEW MINIMUM 3" VENT
INDICATED ON THE PLANS.
THRU ROOF AS REQUIRED.
NO rtr�+s shad ba made to the
of work rritho)'wZ pdorilding ^e�unpmall of
ZO t =I a � _vE:;<cn3 V -Til regLgra a n>rx plata subn tW
Wol may U54udo adahmW- plain faView fps.
cr T E P17-
? a IRIS- FOR;
O;VEI&,hanical
EMlectricaf
❑ Plumbing
l+d Gas Piping
City of Tukwila
BI II!_rDWIG DIVISION,
RM COPY
I?
�-it N. IY G1fo' oaf S
F!n -ew uiwo ' 'j N Subject to errors and rmi'
a' :` �S'ig3?its do 2 c; -
c
-,,Iv
„� ”' ordinance.
sr `f
BUILDING DIVISCIN
RECEIVED
APR 0 4 2016
TUKWILA
PUBLIC WORKS
ftft D PCF
PLtANCF
j oVeb
APR 0 7 2016
k)7
City of Tukwila
UILDING OMSION'�
l fy C'F STUKWILA
�4,Ml 2 9 2016
;PERMH T CENTER
A Subsidiary of the Luxottica Group
4000 Luxottica Place Mason, Ohio 45040
Store # C6427
SOUTtiCENTER SQUARE
17 100 Southcenter Parkway
Tukwila, WA 98 188
SPACE # 128
Active RCV151on Number
Revi5ion5:
Mark Date 13y Description
0
0
0
0
A
311 Elm Street Suite 600
Cincinnati OH 45202
513 241 3000
xmm.frch.com
l;
FRCH / A�chitcctul-c, Il�c., P.C.
Seal .a111"a_
E�C�iTES
Thorson Baker + Associates
C 0 N S U L T I N G E N G I N E E R S
3030 West Streetsboro Road (330) 659-6688 Ph.
Richfield, Ohio 44286 (330) 659-6675 Fax
ARCHITECTURAL 5YMBOL5:
ODOOR NUMBER
REVISIONS
ROOM NAME
ROOM NUMBER
X ELEVATION NO. eX DETAIL NO.
A-X.X SHEET NO. A-X.X SHEET NO.
X SECTION NO. X -X. X ELEVATION NO.
A-X.X SHEET NO. SHEET NO.
PROJECT TYPE: ❑ NEW
CORPORATE RELOCATION
❑ FRANCHISE ❑ REMODEL (OPEN)
❑ REMODEL (CLOSED)
LAD TYPE:
❑ FULL LAB ❑ NO LAB
FINISH LAB
51TE TYPE:
❑ INDOOR LOCATION
OUTDOOR LOCATION
Pearle 5tandard Version Number:
ECC I .0
Pearle Vision Project No. CG427
Architect's Protect No. 032580.000
Title
SANITARY PLUMBING
PLAN
Date : 03.18.16 ISheet
Drawn 5y TBA
Checked 5y TBA
5tore Number I O
CG4271-Of P-
GENERAL PLUME31NG NOTES
FIELD VERIFY EXACT CONDITIONS AND ROUTING OF WORK. CONTACT ENGINEER OR
A.
ARCHITECT IMMEDIATELY SHOULD ANY CONFLICT ARISE.
EXISTING PLUMBING INFORMATION IS BASED ON LIMITED EXISTING BUILDING
DRAWINGS AND FIELD WORK. THE G.C. SHALL FIELD VERIFY THE EXISTING
B.
CONDITIONS FOR ACCURACY. NO ADDITIONAL_ COMPENSATION SHALL BE ALLOWED
FOR REVISIONS TO THE DESIGN TO CORRECT FOR EXISTING CONDITIONS NOT AS
INDICATED ON THE PLANS.
C
G.C. TO VERIFY EXISTING CONDITIONS AND COORDINATE CONFLICTS PRIOR TO
BIDDING.
D
ANYTHING NOT NOTED AS EXISTING IS TO BE FURNISHED AND INSTALLED AS PART
OF THIS PROJECT.
REFER TO DRAWINGS, GENERAL NOTES OF OTHER DISCIPLINES, AND PROJECT
E
SPECIFICATIONS FOR ADDITIONAL PROJECT INFORMATION AND REQUIREMENTS.
NOTIFY ENGINEER OF ANY CONFLICTS BETWEEN THE INFORMATION PRESENTED AND
FIELD CONDITIONS.
PROVIDE STOP VALVES AT EVERY FIXTURE ON BOTH HOT AND COLD WATER SUPPLY
F.
LINES. VALVES, ESCUTCHEONS, FITTINGS, ETC. MUST BE CHROME PLATED. WHERE
EXPOSED, CHROME PLATED PIPE IS TO BE USED.
G
ALL SANITARY PIPING INSTALLED UNDERGROUND IS TO BE PITCHED @ 1% SLOPE
EXCEPT FOR 2" LINES WHICH SHALL BE PITCHED AT 2% SLOPE.
H.
ALL OVERHEAD PIPING IS TO BE ROUTED TIGHT TO BUILDING STRUCTURE.
1.
BACKFLOW PREVENTER DRAINS TO BE ROUTED TO NEAREST FLOOR DRAIN/MOP
SINK.
J.
PIPING IS NOT PERMITTED IN DEMISING WALLS.
CLEAN AND REFURBISH EXISTING PLUMBING FIXTURES TO BE RE -USED. FIELD VERIFY
N
EXISTING PLUMBING FIXTURES ARE IN PROPER WORKING ORDER. NOTIFY TENANT
IMMEDIATELY SHOULD OPERATIONAL CHECK OF FIXTURES REVEAL ANY MAJOR
COMPONENT FAILURES.
O.
DO NOT ROUTE ANY WATER CONVEYING PIPING OVER ELECTRICAL EQUIPMENT.
P
ALL EXPOSED OR ACCESSIBLE P -TRAPS MUST BE PROVIDED WITH BOTTOM
CLEANOUT PLUGS.
Q
INSULATE EXPOSED P -TRAPS, HOT AND COLD VALVES AND PIPING SERVING
HANDICAPPED LAVATORIES.
PRIOR TO ANY ISOLATION OF SYSTEMS, SHUTDOWNS OR DEMOLITION THE G.C.
R
SHALL PROVIDE NECESSARY INVESTIGATION AND NOTIFY THE FACILITIES
ENGINEERING/MAINTENANCE PERSONNEL OF WORK TO BE PERFORMED SO AS TO
AVOID ANY DETRIMENTAL SHUTDOWN OF SYSTEMS TO ADJACENT SPACES.
SPACE ABOVE CEILING IS INDICATED TO BE A RETURN AIR PLENUM. CONSTRUCTION
MATERIALS ABOVE CEILING SHALL BE NONCOMBUSTIBLE, OR HAVE A MAXIMUM 25
S
FLAME SPREAD AND 50 SMOKE DEVELOPMENT FINISH RATING. WIRING SHALL BE
LABELED PLENUM RATED TYPE PER NEPA 70.
NO PLUMBING OR FIRE PROTECTION PIPING OR EQUIPMENT MAY BE SUPPORTED
T.
FROM THE SUSPENDED CEILING SYSTEM, BUT MUST BE INDEPENDENTLY
SUPPORTED FROM THE BUILDING STRUCTURE.
ALL FLOOR DRAI NS/CLEANOUTS ARE TO BE INSTALLED FLUSH WITH THE FINISHED
U.
FLOOR.
G.C. TO X-RAY EXISTING FLOOR TO DETERMINE LOCATIONS OF THE EXISTING UNDER
V.
FLOOR BUILDING COMPONENTS, PRIOR ANY CORE DRILLING OR PLUMBING
ROUGH -IN WORK IS STARTED.
RECEIVED
APR 0 4 2016
TUKWILA
PUBLIC WORKS
ftft D PCF
PLtANCF
j oVeb
APR 0 7 2016
k)7
City of Tukwila
UILDING OMSION'�
l fy C'F STUKWILA
�4,Ml 2 9 2016
;PERMH T CENTER
A Subsidiary of the Luxottica Group
4000 Luxottica Place Mason, Ohio 45040
Store # C6427
SOUTtiCENTER SQUARE
17 100 Southcenter Parkway
Tukwila, WA 98 188
SPACE # 128
Active RCV151on Number
Revi5ion5:
Mark Date 13y Description
0
0
0
0
A
311 Elm Street Suite 600
Cincinnati OH 45202
513 241 3000
xmm.frch.com
l;
FRCH / A�chitcctul-c, Il�c., P.C.
Seal .a111"a_
E�C�iTES
Thorson Baker + Associates
C 0 N S U L T I N G E N G I N E E R S
3030 West Streetsboro Road (330) 659-6688 Ph.
Richfield, Ohio 44286 (330) 659-6675 Fax
ARCHITECTURAL 5YMBOL5:
ODOOR NUMBER
REVISIONS
ROOM NAME
ROOM NUMBER
X ELEVATION NO. eX DETAIL NO.
A-X.X SHEET NO. A-X.X SHEET NO.
X SECTION NO. X -X. X ELEVATION NO.
A-X.X SHEET NO. SHEET NO.
PROJECT TYPE: ❑ NEW
CORPORATE RELOCATION
❑ FRANCHISE ❑ REMODEL (OPEN)
❑ REMODEL (CLOSED)
LAD TYPE:
❑ FULL LAB ❑ NO LAB
FINISH LAB
51TE TYPE:
❑ INDOOR LOCATION
OUTDOOR LOCATION
Pearle 5tandard Version Number:
ECC I .0
Pearle Vision Project No. CG427
Architect's Protect No. 032580.000
Title
SANITARY PLUMBING
PLAN
Date : 03.18.16 ISheet
Drawn 5y TBA
Checked 5y TBA
5tore Number I O
CG4271-Of P-
E
75
I
0
f
In
6�
0
i
Qb
0
CV
N
.;
ry
q
DOMESTIC WATER PLUMBING FLAN
SCALE: 114" = P-0"
PLUMBING 5YM FBOL5 (ALL SYM15CL5 5t1CWN a.KE NOT NECCS AKILY USED ON THE DRAWINGS)
ELBOW OF
QTY. rAN F.U.
EACH
5AN F U.
TOTAL
C.W F.U.
EACH
WTR. DMD.
TOTAL
T*P RELIEF VALVE
O ELBOW DOW14
G.0
2.2
4.4
(E) LAVATORY - 5K5
WALL CLEANOUT
TEE OUTLET UP
0.7
1.4
(E) SERVICE SINK - SS
1 3.0
FLOOR CLEANOUT
- ism TEE OUTLET DOWN
3.0
(E) FLOOR DRAIN - FD 1
2 2.0
p
PLUMBING FIXTURES
---+}�- UNION
SINK (5K4 * 5K7)
4 2.0
8.0
2.0
POINT OF NEW CONNECTION
6 BALL VALVE
1 0.5
TO E'CISTING PIPING OR SYSTEM
-- - --- COLD WATER PIPING (CW)
OI -'
DRAWING NOTE REFERENCE
-- HOT WATER PIPING (HW)
WSFU
WATER SUPPLY FIXTURE UNITS
SANITARY PIPING (SAN)
O/H
OVERHEAD
------------ SANITARY VENT PIPING (V)
DN
DOWN
COLD
U/G
UNDERGROUND
7 CAP ON END LINE
1/2"
1/2"
I I/2"
EX
EXISTING
PLUM6ING CALCULATIONS
PLUMBING FIXTURE
QTY. rAN F.U.
EACH
5AN F U.
TOTAL
C.W F.U.
EACH
WTR. DMD.
TOTAL
(E) W.C. (PRESSURE ASSIST)
2 3.0
G.0
2.2
4.4
(E) LAVATORY - 5K5
2 1.0
2.0
0.7
1.4
(E) SERVICE SINK - SS
1 3.0
3.0
3.0
3.0
(E) FLOOR DRAIN - FD 1
2 2.0
4.0
0.0
0.0
SINK (5K4 * 5K7)
4 2.0
8.0
2.0
8.0
(R) ELECTRIC WATER COOLER (EWC2)
1 0.5
0.5
0.25
0.25
TOTALS
EXPOSED, CHROME PLATED PIPE IS TO BE USED.
23.5
ALL SANITARY PIPING INSTALLED UNDERGROUND IS TO BE PITCHED @ 1% SLOPE
17.05
5ERVICE CONNECTION 51ZE SAN. 4" WATER 1"
PLUMBING FIXTURE
CONNECTION SCHEDULE
FIXTURE
DRAIN
HOT
COLD
VENT
SINK SK4 SK
2"
1/2"
1/2"
I I/2"
FLOOR CLEAN OUT CO
PIPE SIZE
-
-
-
WALL CLEAN OUT WC
PIPE SIZE
-
-
-
ELECTRIC WATER HEATER WH
-
3/4
3/4
-
ELECTRIC WATER COOLER EWC
1 1 /2"
-
I /2"
1 112"
NOTE:(5K1 THRU 4) CONTRACTOR WILL BE REQUIRED TO FURNISH ALL LABOR, PIPING MATERIALS
AND APPURTENANCES NECESSARY TO COMPLETE INSTALLATION OF SINKS, FAUCETS AND DRAINS
FURNISHED BY TENANT.
PLAN NORTH
TRUE NORTH
KEY N OTE5
MARK
DESCRIPTION
FIELD VERIFY EXACT CONDITIONS AND ROUTING OF WORK. CONTACT ENGINEER OR
EXTEND AND CONNECT TO EXISTING DOMESTIC WATER MAIN. FIELD VERIFY EXACT
O
LOCATION AND SIZE OF EXISTING MAIN AND METERING REQUIREMENTS PRIORTO
EXISTING PLUMBING INFORMATION IS BASED ON LIMITED EXISTING BUILDING
START OF WCRK.
DRAWINGS AND FIELD WORK. THE G.C. SHALL -1ELD VEPJFY THE EXISTING
PROVIDE NEW ELECTRIC WATER HEATER WH 1. PROVIDE TEMPERATURE AND
OPRESSURE
RELIEF VALVE TO DRAIN TO EXISTING SERV!CC SINK SS AND TERMINATE
FOR REVISIONS TO THE DESIGN TO CORRECT EOR EXISTING CONDITIONS NOT AS
WITH AN AIR GAP PER ALL STATE AND LOCAL CODES. SEE DETAIL G/ P2.0 FOR
INDICATED ON THE PLANS.
ADDITIONAL INFORMATION.
O3
ROUTE 1/2" COLD WATER SUPPLY PIPING OVER TO EYEWASH STATION.
BIDDING.
NEW HAND SINK. PROVIDE 1/2" COLD AND HOT WATER SUPPLY PIPING WITH A
O4
POINT OF USE A55E 1070 THERMOSTATIC MIXING VALVE AND SET AT 110°F.
OF THIS PROJECT.
PROVIDE ALL HARDWARE AND APPURTENANCES FOP, A COMPLETE INSTALLATiON.
O
ROUTE 1/2" COLD AND 1/2" HOT WATER SUPPLY PIPING DOWN TO EXISTING UTILITY
SPECIFICATIONS FOR ADDITIONAL PROJECT INFORMATION AND REQUIREMENTS.
SINK.
O
ROUTE 1/2" COLD WATER SUPPLY PIPING TO RELOCATED ELECTRIC WATER COOLER.
APPROVED
APR i 1
City Of Tu l
UILDING DIVISION
RECEIVED
CiTY OF TUKWILA
A Subsidiary of the Luxottica Group
4000 Luxottica Place Mason, Ohio 45040
Store # C6427
SOUTIICENTER SQUARE
17 100 Southcenter Parkway
Tukwila, WA 98 188
SPACE # 128
Active Revision Number
Revisions:
Mark Date BY Description
0
0
FAI
0
0
Architect/
Engineer
311 Elm Street Suite 600
Cincinnati OH 45202
513 241 3000
www.fr.h.com
FRCH / Architecture, Inc., P.C.
Seal s
��Slzj
U
Thorson Baker + Associates
C O N S U L T I N G E N G I N E E R S
3030 West Streets boro Road (330) 659-6688 Ph.
Richfield, Ohio 44286 (330) 659-6675 Fax
ARCHITECTURAL SYMBOLS:
( ) DOOR NUMBER
REVISIONS v
ROOM NAME
ROOM NUMBER
X ELEVATION NO. e DETAIL NO.
11 A-X.X SHEET NO. A-X.X SHEET NO.
X SECTION NO. X -X. X ELEVATION NO.
A-X.X SHEET NO. SHEET NO.
PROJECT TYPE: ❑ NEW
CORPORATE RELOCATION
❑ FRANCHISE ❑ REMODEL (OPEN)
❑ REMODEL (CLOSED)
LAB TYPE:
❑ FULL LAB ❑ NO LAB
FINISH LAB
51TE TYPE:
❑ INDOOR LOCATION
OUTDOOR LOCATION
Pearle Standard Version Number:
ECC I .0
MAR 2 9 20116- Peade Vision Project No. CG427
Architect's Project No. 032580.000
PERMIT CENTER
Title
DOMESTIC WATER
PLUMBING PLAN
Date 03. 18. 1 G Sheet
Drawn By TBA
Checked By TBA
Store Number
CG4271Of
-
GENERAL PLUMBING NOTES
A
FIELD VERIFY EXACT CONDITIONS AND ROUTING OF WORK. CONTACT ENGINEER OR
ARC IITECT IMMEDIATELY SHOULD ANY CONFLICT ARISE.
EXISTING PLUMBING INFORMATION IS BASED ON LIMITED EXISTING BUILDING
DRAWINGS AND FIELD WORK. THE G.C. SHALL -1ELD VEPJFY THE EXISTING
B.
CONDITIONS FOR ACCURACY. NO ADDITIONAL COMPENSATION SHALL BE ALLOWED
FOR REVISIONS TO THE DESIGN TO CORRECT EOR EXISTING CONDITIONS NOT AS
INDICATED ON THE PLANS.
C
G.C. TO VERIFY EXISTING CONDITIONS AND COORDINATE CONFLICTS PRIOR TO
BIDDING.
D
ANYTHING NOT NOTED AS EXISTING IS TO BE FURIJISHED AND INSTALLED AS PART
OF THIS PROJECT.
REFER TO DRAWINGS, GENERAL NOTES OF OTHER DISCIPLINES, AND PROJECT
E
SPECIFICATIONS FOR ADDITIONAL PROJECT INFORMATION AND REQUIREMENTS.
NOTIFY ENGINEER OF ANY CONFLICTS BETWEEN THE INFORMATION PRESENTED AND
FIELD CONDITIONS.
PROVIDE STOP VALVES AT EVERY FIXTURE ON BOTH HOT AND COLD WATER SUPPLY
F.
LINES. VALVES, ESCUTCHEONS, FITTINGS, ETC. MUST BE CHROME PLATED. WHERE
EXPOSED, CHROME PLATED PIPE IS TO BE USED.
G
ALL SANITARY PIPING INSTALLED UNDERGROUND IS TO BE PITCHED @ 1% SLOPE
EXCEPT FOR 2" LINES WHICH SHALL BE PITCHED AT 2% SLOPE.
H.
ALL OVERHEAD PIPING IS TO BE ROUTED TIGHT TO BUILDING STRUCTURE.
1.
BACKFLOW PKEVENTER DRAINS TO BE ROUTED TO NEAREST FLOOR DRAIN/MOP
SINK.
J.
PIPING IS NOT PERMITTED IN DEMISING WALLS.
CLEAN AND REFURBISH EXISTING PLUMBING FIXTURES TO BE PE -USED. FIELD VERJFY
N
EXISTING PLUMBING FIXTURES ARE IN PROPER WORKING ORDER. NOTIFY TENANT
IMMEDIATELY SHOULD OPERATIONAL CHECK OF FIXTURES REVEAL ANY MAJOR
COMPONENT FAILURES.
O.
DO NOT ROUTE ANY WATER CONVEYING PIPING OVER ELECTRICAL EQUIPMENT.
P
ALL EXPOSED OR ACCESSIBLE P -TRAPS MUST BE PROVIDED WITH BOTTOM
CLEANOUT PLUGS.
Q
INSULATE EXPOSED P -TRAPS, HOT AND COLD VALVES AND PIPING SERVING
HANDICAPPED LAVATORIES.
PRIOR TO ANY ISOLATION OF SYSTEMS, SHUTDOWNS OR DEMOLITION THE G.C.
R
SHALL PROVIDE NECESSARY INVESTIGATION AND NOTIFY THE FACILITIES
ENGINEERING/MAINTENANCE PERSONNEL OF WORK TO BE PERFORMED SO AS TO
AVOID ANY DETRIMENTAL SHUTDOWN OF SYSTEMS TO ADJACENT SPACES.
SPACE.ABOVE CEILING IS INDICATED TO BE A RETURN AIR PLENUM. CONSTRUCTION
MATERIALS ABOVE CEILING SHALL BE NONCOMBUSTIBLE, OR HAVE A MAXIMUM 25
S
FLAME SPREAD AND 50 SMOKE DEVELOPMENT FINISH RATING. WIRING SHALL BE
LABELED PLENUM RATED TYPE PER NEPA 70.
NO PLUMBING OR FIRE PROTECTION PIPING OR EQUIPMENT MAY BE SUPPORTED
T.
FROM THE SUSPENDED CEILING SYSTEM, BUT MUST BE INDEPENDENTLY
SUPPORTED FROM THE BUILDING STRUCTURE.
ALL FLOOR DRAINS/CLEANOUTS ARE TO BE INSTALLED FLUSH WITH THE FINISHED
U
FLOOR.
G.C. TO X-RAY EXISTING FLOOR TO DETERMINE LOCATIONS OF THE EXISTING UNDER
V.
FLOOR BUILDING COMPONENTS, PRIOR ANY CORE DRILLING OR PLUMBING
ROUGH -IN WORK IS STARTED. -
APPROVED
APR i 1
City Of Tu l
UILDING DIVISION
RECEIVED
CiTY OF TUKWILA
A Subsidiary of the Luxottica Group
4000 Luxottica Place Mason, Ohio 45040
Store # C6427
SOUTIICENTER SQUARE
17 100 Southcenter Parkway
Tukwila, WA 98 188
SPACE # 128
Active Revision Number
Revisions:
Mark Date BY Description
0
0
FAI
0
0
Architect/
Engineer
311 Elm Street Suite 600
Cincinnati OH 45202
513 241 3000
www.fr.h.com
FRCH / Architecture, Inc., P.C.
Seal s
��Slzj
U
Thorson Baker + Associates
C O N S U L T I N G E N G I N E E R S
3030 West Streets boro Road (330) 659-6688 Ph.
Richfield, Ohio 44286 (330) 659-6675 Fax
ARCHITECTURAL SYMBOLS:
( ) DOOR NUMBER
REVISIONS v
ROOM NAME
ROOM NUMBER
X ELEVATION NO. e DETAIL NO.
11 A-X.X SHEET NO. A-X.X SHEET NO.
X SECTION NO. X -X. X ELEVATION NO.
A-X.X SHEET NO. SHEET NO.
PROJECT TYPE: ❑ NEW
CORPORATE RELOCATION
❑ FRANCHISE ❑ REMODEL (OPEN)
❑ REMODEL (CLOSED)
LAB TYPE:
❑ FULL LAB ❑ NO LAB
FINISH LAB
51TE TYPE:
❑ INDOOR LOCATION
OUTDOOR LOCATION
Pearle Standard Version Number:
ECC I .0
MAR 2 9 20116- Peade Vision Project No. CG427
Architect's Project No. 032580.000
PERMIT CENTER
Title
DOMESTIC WATER
PLUMBING PLAN
Date 03. 18. 1 G Sheet
Drawn By TBA
Checked By TBA
Store Number
CG4271Of
-
0
L(i
0
d
C)
N
A Subsidiary of the Luxottica Group
4000 Luxottica Place Mason, Ohio 45040
Store # C6427
SOUTIICENTER SQUARE
17100 5outhcenter Parkway
Tukwila, WA 98 188
5PACE # 128
I
Active Revision Number
ReVl51on5:
Mark Date by Description
0
A
A
A
311 Elm Street Suite 600
Cincinnati OH 45202
513 241 3000
wwwftc h . co m
FRCH / ArchiLr_GLurc, Inc., 1-.C.
Seal
Git8117
7*3�
i
Thorson Baker Associates
C O N S U L T I N G E N G I N E E R S
3030 West Streetsboro Road (330) 659-6688 Ph.
Richfield, Ohio 44286 (330) 659-6675 Fax
ARCHITECTURAL 5YMBOL5:
REVISIONS O DOOR NUMBER
ROOM NAME
ROOM NUMBER
X ELEVATION NO. eX DETAIL NO.
A-X.X SHEET NO. A-X.X SHEET NO.
X%,SECTION NO. X -X. X ELEVATION NO.
A-X.X SHEET NO. 5HEET NO.
PROJECT TYPE: ❑ NEW
CORPORATE RELOCATION
❑ FRANCHISE ❑ REMODEL (OPEN)
❑ REMODEL (CLOSED)
LAB TYPE:
❑ FULL LAB ❑ NO LAB
FINISH LAB
51TE TYPE:
❑ INDOOR LOCATION
OUTDOOR LOCATION
Pearle Standard Version Number:
ECC IGO
Pearle Vision Project No. CG427
Architect's Project No. 032580.000
Title
PLUMBING LEGEND
AND D ETAI L5
Date 03.18.16 Sheet
Drawn E y TBA
Checked By TBP`
5tore Number F-2.0
CG4271 Of
a
HANGER ROD
LOCKING NUT
SUPPORT NUT
HOT WATER SUPPLY OUTLET,
HW
SEE PLANS
G}N
HEAVY DUTY CLEVIS
COLD WATER SUPPLY INLET,
HANGER. MATERIAL TO
SEE PLANS
MATCH PIPE
SHUT-OFF VALVES PROVIDE EWH WITH
EXPANSION TANK ON
UNION OR APPROVED FLEX COLD WATER SUPPLY
CONNECTOR, TYPICAL SIDE, AMTROL OR EQUAL
PIPE
Fr
CU!VIS HANGER
FULL UNE 51ZE COPPER UNI5TRUT P- I OOOT
SINGLE HORIZONTAL RUNS
ROUND SECURED
RELIEF DRAIN TO HUB I CHANNEL, BOLT TO
NO VAPOR BARRIER INSULATION
POLISHED BRONZE
DRAIN OR MOP SINK -y 2 3/8" DOLTS, URZ WITH
U N I N S U LATE D PIPE S U P FO RT DET.
0 0 o MINIMUM
5
CLEANOUT PLUG
-
SCALE: NONE
o00
i r 145 DR-\CKCT, (3) 1/2"
HOSE BIB DRAIN BOLTS AND NUTS,
VALVE BEYOND TYPICAL OF 2 LOCATIONS
HANGER ROD
SEALANT
CONCRETE SLAB
A5ME PRESSURE � TEMP-
ERA E 2" X 16 GA. GALVANIZED
LOCKING NUT A5J/55L BUTT
SUPPORT NUTS - -
BRONZE TOP
FLUSH WITH
FINISHED FLOOR
FINISHED FLOOR
5AW-CUT 24" x 24"
AREA OF EXISTING
SHEET METAL STRAP
STRIP (TYPICAL)
HEAVY DUTY CI.EV15
FINI5HED FLOOR
OR WALK
CONCRETE, CENTERED
DRAIN
HANGER. MATERIAL TO
W/ SLOPING SURF. TO
DRAIN
SANITARY OR 5TORMJ
WALL
GALVANIZED SHEET METAL OR OTHER
COPRO51ON-RESI5TANT MATERIAL
CONSTRUCTION WATERTIGHT PAN.
MATCH PIPE
PIPE
FIBERGLASS
c
v
o
C
i i i i
'� • T ��
FURNISH WITH SEDIMENT
FULL LINE SIZE COPPER
INSULATION
TRAP —_—_
RELIEF DRAIN TO
SUPPORT WATER HEATER ASSEMBLY FROM EXISTING MOP 51NK
PER SPECS
r• .-
�_�
PLATFORM. REFERTO ARCHiTEC,URAL
STRUCTURE AT "'
GRADE AT LOWER
DRAWINGS FOR ADDITIONAL INFORMATION.
COORDINATE WITH GENERAL TRADES
CONTRACTOR
180° RIBBED I SGA.
SHIELD SIMILAR RIB (TYPICAL)
BRASS PLUG
IN51DE CAULK
UPPER LEVEL
TO TENANTS
LEVEL
TO ANVIL #I G82' 12" 2•
AS REQUIRED FITTING OR
SANITARY SEWER
EXTENSION TO 501L OR WASTE
WALL CLEANOUT DETAIL
ELECTRIC WATER HEATER DETAIL
INSULATED PIPE SUPPORT DET.
TYPICAL
FLOOR CLEANOUT DET.
TYPICAL FLOOR DRAIN DETAIL
7
4
2
SCALE: NONE
SCALE: NONE
SCALE: NONC
SCALE: NONE
SCALE: NONE
/ I
/
SEE NOTE#2
N. /
211 /
3"
\�� �/r
STAINLESS STEEL
CLAMPING RING WATER CUT-OFF MASTIC
I"
1-1/2"
r
/// ��
/ /
I 3"
PRE -MOLDED
PIPE SEAL SPLICING CEMENT
1/2"
\
I/2"
2„ I//TN,
/
/// I I 1-1/2�
ROOFING MEMBRANE LAP5EALANT
3/4"
'/
3/4"
IN,
INSULATION
3/411
.11/
/ %
/
311
e
\�
3/4"
3"
3"
// \`
NOTE:
DO NOT TRIM DECK FLANGE
3/4"
3"
\
/
1/211
FORI
REV E
CODE Cs PLIAM
APPROVED
3"
DETAIL NOTES
2016
APR 0 7
I . PRE -MOLDED PIPE SEAL CANNOT BE CUT VERTICALLY TO BE INSTALLED.
2 PRE=MOLDED PIPE SEAL MUST HAVE INTACT RIB AT TOP EDGE REGARDLESS
VERIFY ALL CONDITIONS IN FIELD.
OF PIPE DIAMETER.
WHEN PREFABRICATED PIPE SEAL CANNOT BE INSTALLED, USE FIELD
3
city of
�7
FABRICATED PIPE SEAL. SEE ALTERNATE PIPE FLASHING DETAIL.
BUILDING �����
.r� r'o c 1'.
+`� ;=• — ` � E
DEMOLITION
4. FOR BALLAST SYSTEMS, REPLACE BALLAST AFTER WORK 15 COMPLETED.
t:;= TUKWILA
DISCONNECT AND REMOVE FROM PREMISES, ALL
FLANGE SHALL BE SET BY ROOFER. COORDINATE WITH ROOFING
5'
EXISTING MECHANICAL EQUIPMENT, DUCT WORK,
PLUMBING FIXTURES, PIPING, SYSTEM, ETC., NOT
CONTRACTOR.
G. VENTS SHALL BE A MINIMUM OF 15'-0" FROM AIR INTAKES.
d€ ' 9 2011S
BEING REUSED.
7. SEE ARCHITECTURAL ROOF PLANS AND DETAILS FOR MORE INFORMATION.
.ERMIT CENTER
PIPE THRU ROOF DETAIL NEEDED)
WATER 150MFTRIC
0
5ANITARY
150METRIC
(IF
9
10
(5
SCALE: NONE
SCALE: NONE
SCALE: NONE
ReVl51on5:
Mark Date by Description
0
A
A
A
311 Elm Street Suite 600
Cincinnati OH 45202
513 241 3000
wwwftc h . co m
FRCH / ArchiLr_GLurc, Inc., 1-.C.
Seal
Git8117
7*3�
i
Thorson Baker Associates
C O N S U L T I N G E N G I N E E R S
3030 West Streetsboro Road (330) 659-6688 Ph.
Richfield, Ohio 44286 (330) 659-6675 Fax
ARCHITECTURAL 5YMBOL5:
REVISIONS O DOOR NUMBER
ROOM NAME
ROOM NUMBER
X ELEVATION NO. eX DETAIL NO.
A-X.X SHEET NO. A-X.X SHEET NO.
X%,SECTION NO. X -X. X ELEVATION NO.
A-X.X SHEET NO. 5HEET NO.
PROJECT TYPE: ❑ NEW
CORPORATE RELOCATION
❑ FRANCHISE ❑ REMODEL (OPEN)
❑ REMODEL (CLOSED)
LAB TYPE:
❑ FULL LAB ❑ NO LAB
FINISH LAB
51TE TYPE:
❑ INDOOR LOCATION
OUTDOOR LOCATION
Pearle Standard Version Number:
ECC IGO
Pearle Vision Project No. CG427
Architect's Project No. 032580.000
Title
PLUMBING LEGEND
AND D ETAI L5
Date 03.18.16 Sheet
Drawn E y TBA
Checked By TBP`
5tore Number F-2.0
CG4271 Of
a
E
1
0
15:
<V
"
N
3
2
0
s
n
m
U
s
0
N
O
U
.o
a
CV
ry
r
MECHANICAL 5PECIffICATION5
DIV15ION 1 5 - MECHANICAL
I. GENERAL PROVISIONS
A. GENERAL CONDITIONS, CODES * STANDARDS
1 . GENERAL CONDITIONS OF THE CONTRACT FOUND IN THE ARCHITECTURAL
DRAWINGS, GENERAL AND SPECIAL CONDITIONS OF THE AMERICAN
INSTITUTE OF ARCHITECTS (AIA) (N5PE)(NEC) AND ANY OF THE TENANT'S
GENERAL REQUIREMENTS SHALL APPLY UNLESS NOTED OTHERWISE.
2. REFER TO THE GENERAL.CONDITION5 ON THE ARCHITECTURAL
DOCUMENTS AND THE GENERAL AND SPECIAL CONDITIONS OF THE AIA
FOR ADDITIONAL REQUIREMENTS REGARDING; SAFETY, COORDINATION
COOPERATION, WORKMANSHIP, PROTECTION, CUTTING AND
PATCHING, DAMAGE TO OTHER WORK, PRELIMINARY OPERATIONS,
STORAGE, ADJUSTMENTS, CLEANING, ETC.
3. ALL WORK SHALL BE IN CONFORMANCE WITH ALL LOCALLY ENFORCED,
FEDERAL, STATE AND LOCAL CODES AND ORDINANCES INCLUDING ANY
SPECIAL THE TENANT REQUIREMENTS IN ADDITION TO THOSE SPECIFIED.
4. CONTRACTOR SHALL PAY FOR AND OBTAIN ALL NECESSARY LICENSES
PERMITS AND INSPECTIONS UI D TOP E WIT E W .
REQ RE ROCS D H TH ORK
THIS SHALL INCLUDE ALL REQUIRED COORDINATION WITH THE LOCAL
UTILITY COMPANIES AND THEIR ASSOCIATED FEES OR
COSTS.
B. SCOPE OF WORK
1 . THIS CONTRACT SHALL INCLUDE THE FURNISHING, INSTALLING,
CONNECTING, AND OPERATION OF ALL EQUIPMENT WHICH I5 A PART OF
THE MECHANICAL SYSTEMS AS SHOWN ON THE DRAWINGS AND AS
REQUIRED BY SIMILAR INSTALLATIONS. ANY MATERIAL OR LABOR WHICH
IS NEITHER SHOWN ON THE DRAWINGS NOR CALLED FOR IN THE
SPECIFICATIONS, BUT WHICH IS OBVIOUSLY NECESSARY TO COMPLETE
THE WORK AND WHICH IS USUALLY INCLUDED IN WORK OF A SIMILAR
CHARACTER SHALL BE FURNISHED AND INSTALLED UNDERTHI5
CONTRACT AT NO ADDITIONAL COST TO THE TENANT. CONTRACTOR
SHALL PROVIDE ALL LABOR AND MATERIALS REQUIRED TO PROVIDE THE
TENANT A COMPLETE, CODE APPROVED AND OPERATIONAL MECHANICAL
SYSTEMS.
2. CAREFULLY READ SPECIFICATION FOR ALL PARTS OF THE WORK SO AS
TO BECOME FAMILIAR WITH ALL TRADES' WQRK SCOPE. CONSULT WITH
OTHER TRADES TO INSURE PROPER LOCATIONS AND AVOID
INTERFERENCES. ANY CONFLICT SHALL BE BROUGHT TO THE ATTENTION
OF THE TENANT BEFORE WORK I5 COMMENCED.
3. CONTRACTORS SHALL BE HELD TO HAVE EXAMINED THE PREMISES AND
SITE SO AS TO COMPARE THEM WITH THE DRAWINGS AND
SPECIFICATIONS, NOTE THE EXISTING CONDITIONS AND OTHER WORK
THAT WILL BE REQUIRED, AND THE NATURE OF THE CONDITIONS UNDER
WHICH THE WORK IS TO BE PERFORMED. NO ALLOWANCE SHALL BE
MADE TO THE CONTRACTOR BY REASON OF THIS FAILURE TO HAVE
MADE SUCH EXAMINATION OR OF ANY ERROR ON HIS PART.
4. ALL EXISTING UTILITY AND MECHANICAL SERVICES SHALL BE FIELD
VERIFIED. CORRECTIONS TO THE DESIGN AND INSTALLATION SHALL BE
MADE WITHOUT ADDITIONAL COST TO THE TENANT.
5. THIS CONTRACTOR IS RESPONSIBLE TO COORDINATE THE OPENINGS
WITH THE GENERAL TRADES CONTRACTOR. THE FINAL LOCATIONS AND
SIZES OF ALL DUCT AND LOUVER OPENINGS SHALL BE PROVIDED BY
THIS CONTRACTOR.
G. THIS CONTRACT SHALL ALSO INCLUDE ALL LABOR, MATERIALS AND
MISCELLANEOUS EXPENSES REQUIRED FOR ALL REQUIRED MECHANICAL
DEMOLITION OF THE EXISTING ARI=AS BEING RENOVATED.
a. THE DEMOLITION SHALL CONSIST OF THE COMPLETE REMOVAL
(PROPERLY DISPOSED OFF
SITE UNLESS OTHERWISE NOTED) OF ALL PLUMBING AND HVAC
EQUIPMENT, PIPING, DUCTWORK, MATERIALS, ETC. NOT REQUIRED IN
THE FINAL DESIGN AND INSTALLATION OF THE PLUMBING AND HVAC
SYSTEMS FOR THE NEW RENOVATED AREAS.
b. ALL UNDERGROUND SERVICES NOT BEING REUSED SHALL BE CAPPED
BELOW THE FLOOR.
c. ALL ABOVE GROUND SERVICES SHALL BE REMOVED BACKTO THEIR
RESPECTIVE MAIN AND CAPPED OR IF THE MAIN I5 NOT REQUIRED,
THE MAIN SHALL BE REMOVED IN IT'S ENTIRETY.
d. COORDINATE ALL DEMOLITION WITH THE ARCHITECTURAL
DOCUMENTS AND THE ARCHITECT AND THE TENANT'S GENERAL
REQUIREMENTS.
7. ALL WORK INCLUDING, BUT NOT LIMITED TO PARTS, MATERIAL,
EQUIPMENT AND LABOR SHALL BE GUARANTEED FOR ONE YEAR AFTER
ACCEPTANCE BY THE ENGINEER AND TENANT. WHERE AN EQUIPMENT
MANUFACTURER HAS A WARRANTY THAT EXCEEDS ONE YEAR, THAT
WARRANTY PERIOD SHALL APPLY TO THI5 PROJECT.
C. DOCUMENTS
I . THE DRAWINGS ARE DIAGRAMMATIC, ALL WORK SHALL BE PERFORMED
AS INDICATED ON THE DRAWINGS UNLESS EXISTING CONDITIONS OR
COORDINATION ISSUES REQUIRE CHANGES. THESE CHANGES SHALL BE
MADE WITH NO ADDITIONAL COST TO THE TENANT.
2. ANY INCIDENTAL ITEMS OR LABOR, ETC. NOT INCLUDED IN THE
SPECIFICATIONS OR THE DRAWINGS BUT REASONABLY IMPLIED AS
NECESSARY FOR THE COMPLETE INSTALLATION OF ALL APPARATUS
SHALL BE INCLUDING IN BID.
3. THE DRAWINGS AND SPECIFICATIONS ARE INTENDED TO SUPPLEMENT
EACH OTHER AND ANY MATERIAL OR LABOR CALLED FOR IN ONE SHALL
BE FURNISHED EVEN THOUGH NOT MENTIONED IN BOTH.
4. IF ERRORS ARE FOUND IN THE DRAWINGS OR SPECIFICATIONS OR
DISCREPANCIES OCCUR BETWEEN THE SAME, OR BETWEEN THE
FIGURES ON THE DRAWINGS, AND THE SCALE OF SAME OR BETWEEN
'THE LARGER AND SMALLER DRAWINGS, OR IN THE DESCRIPTIVE MATTER
ON THE DRAWINGS SHALL BE REFERRED TO THE TENANT FOR REVIEW
AND FINAL DECISION PRIORTO THE BID DUE DATE.
5. THE BIDDING OF THIS WORK WILL CONTEMPLATE THE USE OF
EQUIPMENT AND MATERIALS EXACTLY A5 SPECIFIED HEREIN. WHERE
MORE THAN ONE MANUFACTURER IS MENTIONED ANY ONE MAY BE
UTILIZED. SUBSTITUTE MANUFACTURERS MAY BE OFFERED ONLY AS AN
ALTERNATE TO THE SPECIFIED EQUIPMENT AND MATERIAL.
a. SUBSTITUTIONS
(1) THE MANUFACTURERS AND MODEL NUMBERS INDICATED IN THE
CONTRACT DOCUMENTS ARE FOR THE PURPOSE OF DESCRIPTION
AND TO ESTABLISH A BASE LEVEL OF QUALITY. THE
CONTRACTOR'S BID WILL CONTEMPLATE THE USE OF THE
EQUIPMENT AND MATERIALS EXACTLY AS INDICATED.
(2) THE CONTRACTOR SHALL SUBMI-F FOR APPROVAL, WITH HIS BID
QUOTATION, A LIST OF ANY PROPOSED 5UB5TITUT!ON5 OF
MATERIALS AND EQUIPMENT FOR THOSE ON WHICH THE ORIGINAL
DESIGN WAS BASED. A. FULL DESCRIPTION OF ALL PROPOSED
SUBSTITUTED ITEMS, THE CHANGE TO THEIR BID PRICE OR OTHER
REASONS FOR SUCH SUBSTITUTIONS SHALL ACCOMPANY THE
BID. ALL ACCESSORIES, FEATURES, ETC., SUPPLIED WITH THE
SUBSTITUTED MANUFACTURER'S PRODUCT SHALL AL50 BE
INCLUDED IN THE BID.
(3) IF THE CONTRACTOR DOES NOT SUBMIT PROPOSED
SUBSTITUTIONS WITH THEIR BID THE TENANT SHALL CONSIDER
THE BIDDER TO BE PROPOSING THE MANUFACTURERS AND MODEL
NUMBERS SPECIFIED HEREIN AND SHOWN ON THE CONTRACT
DRAWINGS.
(4) SUBSTITUTIONS AFTER CONTRACT AWARD SHALL NOT BE
PERMITTED.
G. MISCELLANEOUS ITEMS NECESSARY TO COMPLETE THE SYSTEMS CAN
BE OF ANY RECOGNIZED MANUFACTURE PROVIDED THESE ITEMS MEET
MINIMUM STANDARDS AS SET IN THESE SPECIFICATIONS. REFERTO
EACH SECTION FOR ANY SPECIFIC REQUIREMENTS.
D. COORDINATION
I . CONTRACTOR SHALL INCLUDE A VISIT TO THE JOB SITE AND TAKE INTO
CONSIDERATION MECHANICAL, ELECTRICAL AND GENERAL TRADE WORK
CURRENTLY EXISTING AND WORK WHICH MAY BE INSTALLED PRIOR TO
CONTRACT AWARD. RELOCATION OF DUCTWORK, PIPING AND
EQUIPMENT, AS REQUIRED, TO AVOID THI5 WORK SHALL BE PROVIDED
AT NO ADDITIONAL COST TO THE TENANT.
2. CONTRACTOR SHALL VERIFY ALL MEASUREMENTS AT THE BUILDING SITE
BEFORE STARTING ANY FABRICATION OR DOING ANY WORK IN THE
FIELD AND SHALL BE RESPONSIBLE FOR THE CORRECT AND PROPER
MEASUREMENTS OF HIS WORK ALONG WITH RESOLUTIONS FOR ANY
CONFLICT OF SPACE WITH OTHER TRADES.
3. WHERE THE WORK OF TWO OR MORE TRADES INTERFERE WITH EACH
OTHER AND A DEVIATION FROM DESIGN IS NECESSARY, NEITHER WORK
SHALL PROCEED UNTIL THE TENANT HAS BEEN NOTIFIED OF THE
CONFLICT AND THEY HAVE RENDERED A DECISION AS TO WHAT
CHANGES SHOULD BE MADE.
4. CONTRACTOR SHALL LOCATE, IDENTIFY AND PROTECT ANY EXISTING
SERVICES WHICH ARE REQUIRED TO BE MAINTAINED OPERATIONAL AND
SHALL EXERCISE EXTRA CAUTION IN THE PERFORMANCE OF ALL WORK
TO AVOID DISTURBING SUCH FACILITIES. ALL COSTS FOR REPAIR OF
DAMAGES TO SUCH SERVICES SHALL BE PAID BY THE CONTRACTOR
CAUSING THE DAMAGE.
5. IT I5 ESSENTIAL THAT ALL WORK AT THE PROJECT BE DONE AS SUCH
TIME AND IN SUCH MANNER AS NOT TO INTERFERE WITH THE NORMAL
OPERATIONS OF THE FACILITY. A WORK SCHEDULE SHALL BE
ARRANGED WITH THE TENANT TO FACILITATE WORK WITH A MINIMUM
OF INTERFERENCE WITH THE TENANTS OPERATIONS.
G. AREAS TO BE USED FOR STORAGE SHALL BE ONLY AS DIRECTED BY
THE TENANT. ALL STORED MATERIAL SHALL BE RELOCATED OR
REMOVED FROM THE 51TE AS DIRECTED BY THE TENANT.
7. DAILY, AND AT THE COMPLETION OF THE WORK, EACH CONTRACTOR
SHALL REMOVE ALL EXCESS MATERIALS AND DEBRIS CAUSED BY HIS
WORK. UPON COMPLETION OF EACH CONTRACTORS WORK,
CONDITIONS OF THE 5PACE(S) SHALL BE THE SAME AS FOUND PRIOR
TO COMMENCEMENT OF THE WORK. FAILURE TO DO SO MAY RESULT
IN THE TENANT'S EMPLOYMENT OF A SEPARATE SERVICE TO OBTAIN
THIS CONDITION AND REDUCING THE FACTORS CONTRACT AMOUNT BY
THE C05T OF SUCH A SERVICE.
8. EACH CONTRACTOR SHALL BE HELD RESPONSIBLE FOR ALL DAMAGE TO
OTHER WORK CAUSED BY HIS WORK OR THROUGH THE NEGLECT OF
HIS, OR HIS SUB -TRADE'S PERSONNEL. ALL PATCHING, REPAIRING,
REPLACEMENT AND PAINTING, ETC. SHALL BE DONE AS DIRECTED BY
THE TENANT BY THE CRAFTSMEN OF THE TRADES INVOLVED. THE
COSTS OF SUCH WORK SHALL BE PAID BY THE CONTRACTOR CAUSING
THE DAMAGE.
E. METHODS
I . EXCAVATIONS SHALL BE MADE IN OPEN TRENCHES. FLOORS SHALL BE
SAW CUT. PIPING SHALL BE LAID ON AN APPROPRIATELY GRADED G"
BED OF CLEAN AND DRY SAND. ENGINEERED FILL SHALL BE USED TO
BACKFILL TO G" ABOVE THE PIPING. BACKFILL THE REMAINDER OF THE
TRENCH UTILIZING THE EXCAVATED MATERIAL IF APPROVED BY THE
ARCHITECT OR THE TENANT. IF THE EXCAVATED MATERIALS ARE NOT
ACCEPTABLE, ENGINEERED FILL ACCEPTABLE TO THE ARCHITECT SHALL
BE UTILIZED TO BACKFILL THE REMAINDER OF THE TRENCH. BACKFILL
SHALL BE ACCOMPLISHED IN 9" LIFTS WITH ALL LIFTS COMPACTED TO
95% PROCTOR. PATCH FLOORTO MATCH EXISTING.
2. EQUIPMENT, PIPING, DUCTWORK, ETC. SHALL NOT BE SUPPORTED
FROM ANY CEILINGS, OTHER PIPING, CONDUIT OR DUCTWORK, ROOF
DECK, OR J015T BRIDGING. ITEMS SHALL BE SUPPORTED FROM
ACCEPTABLE STRUCTURAL BUILDING COMPONENTS AS DETERMINED BY
THE ARCHITECT AND STRUCTURAL ENGINEER.
3. ALL ROOF PENETRATIONS, FLASHINGS AND COUNTER FLASHINGS SHALL
BE PERFORMED BY THE TENANTS ROOFING CONTRACTOR AT THE
REQUESTING CONTRACTORS COST.
REQUESTING CONTRACTORS COST.
II. INSULATION
A. GENERAL
I. INSTALLATION SHALL CONFORM TO THE MANUFACTURERS
RECOMMENDATIONS, AND IN ACCORDANCE WITH RECOGNIZED
INDUSTRY PRACTICES.
2. CLEAN AND DRY SURFACES PRIOR TO INSULATING.
3. EXTEND INSULATION WITHOUT INTERRUPTION THROUGH WALLS,
FLOORS, HANGERS AND SIMILAR PENETRATIONS.
4. INSULATION JACKET AND FITTING COVER MUST BE PLENUM RATED.
5. IT I5 ESSENTIAL THAT THE INTEGRITY OF THE VAPOR -BARRIER BE
MAINTAINED. SEAL ALL PENETRATIONS OF THE VAPOR BARRIER BY
STAPLES, HANGERS OR WHERE OTHERWISE DAMAGED.
G. MAINTAIN ACCESS TO BALANCING DAMPERS AND VALVES.
7. INSULATION SHALL BE BY OWEN5-CORNING, KNAUF, OR MANVILLE.
B. HVAC
I . INTERNALLY INSULATE WITH I INCH THICK, I - 1/2# DENSITY
ACOUSTICAL INSULATION (AIR SIDE BLACK COATED TO MEET NFPA) ALL
DUCTWORK NOTED AS REQUIRING SUCH. INTERNAL INSULATION SHALL
BE INSTALLED PER THE REQUIREMENTS OF THE 5MACNA GUIDE AND
THE MANUFACTURERS RECOMMENDATIONS. DUCT SIZES NOTED ON
DRAWING ARE SHEET METAL DIMENSIONS.
2. ALL SUPPLY AND OUTSIDE AIR DUCTWORK SHALL BE WRAPPED WITH
I -1 /2 INCH OF 0.75 LB/CU.FT. FIBERGLASS, FOIL BACKED DUCT
WRAPPING.
C. PLUMBING
I . ALL ABOVE GROUND PIPING SHALL BE INSULATED WITH FIBERGLASS
PIPING INSULATION WITH AN ALL SERVICE JACKET AND SELF SEALING LAP
(A5J/SSL).
a. DOMESTIC HOT AND COLD WATER PIPING UP TO 3/4 INCH DIAMETER -
1/2 INCH THICK.
2. FITTINGS AND VALVES SHALL BE INSULATED WITH PRE -MOLDED
FIBERGLASS FITTINGS AND COVERED WITH A PRE -FORMED PVC FITTING
COVER.
III. SPRINKLER
A. GENERAL
I . THE ENTIRE INSTALLATION SHALL CONFORM TO THE REQUIREMENTS OF
NFPA 1 3, THE BUILDING TENANT'S INSURANCE COMPANY, THE LOCALLY
ENFORCED BUILDING CODE, LOCAL BUILDING AND FIRE OFFICIALS AND
ALL OTHER LOCAL AUTHORITIES HAVING JURISDICTION.
2. ALL WORK SHALL BE PERFORMED BY A LANDLORD APPROVED, STATE
LICENSED SPRINKLER CONTRACTOR.
3. THIS WORK SHALL INCLUDE ALL PIPING, FITTINGS, HANGERS,
EQUIPMENT, ETC., REQUIRED TO COMPLETE THE WORK.
4. SPRINKLER HEADS ARE TO BE CENTERED IN LAY -IN CEILING TILES.
HEADS ARE TO BE SPACED SYMMETRICALLY WITH LIGHTING AND OTHER
CEILING FIXTURES WHEN INSTALLED IN DRYWALL CEILINGS.
5. DETERMINE VOLUME AND PRESSURE OF INCOMING WATER5UPPLY
FROM WATER FLOW TEST DATA. REVISE DE51GN WHEN TEST DATA
BECOMES AVAILABLE PRIORTO SUBMITTALS.
G. SUBMITTALS
a. SHOP DRAWINGS:
(1) PREPARE AND SUBMIT SHOP DRAWINGS IN ACCORDANCE WITH
THE MECHANICAL GENERAL PROVISIONS.
(2) SHOW PLANS, CROSS SECTION, ELEVATIONS, DETAILS AND JOB
CONDITIONS, RELATIONSHIP TO OTHER WORK. PIPE SIZES,
ELEVATIONS ABOVE FLOOR, HEAD LOCATIONS, INSPECTORS
TEST CONNECTION, SPRINKLER ENTRANCE, VALVES, ALARMS,
BACKFLOW PREVENTER, FLOW SWITCH AND SUPERVISORY
DEVICES.
(3) SUBMIT DATA ON THE FOLLOWING ITEMS:
(a) PIPING AND COUPLINGS.
(b) WET ALARM VALVE.
(c) BACKFLOW PREVENTER.
(d) VALVES AND SUPERVISORY DEVICES.
(e) SPRINKLER HEADS AND ESCUTCHEON PLATES.
(f) SUPPORTS, HANGERS AND ACCESSORIES.
(g) SEISMIC CALCULATIONS
(4) SUBMIT AND RECEIVE APPROVAL FROM THE AUTHORITY HAVING
JURISDICTION PRIOR TO SUBMITTAL.
(5) ONCE THE AUTHORITY HAVING JURISDICTION HAS APPROVED SHOP
DRAWINGS, THE SUBCONTRACTOR SHALL SEND EIGHT SETS OF
APPROVED STAMPED PLANS AND EQUIPMENT CUTS TO THE
ARCH ITECT FOR APPROVAL.
(G) PLANS SUBMITTED WITHOUT ALL HYDRAULIC CALCULATIONS WILL
BE RETURNED "REJECTED". PROVIDE INDEPENDENT HYDRAULIC
CALCULATION SHEETS.
(7) ALL SPRINKLER PLANS SHALL BEAR THE STAMP OF A REGISTERED
PROFESSIONAL FIRE PROTECTION ENGINEER LICENSED WITH THE
STATE WHERE THE STORE IS LOCATED.
(8) AT THE COMPLETION OF THE PROJECT, PROVIDE TENANT WITH
OPERATION AND MAINTENANCE MANUALS INCLUDING "A5 -BUILT"
RECORD DRAWINGS, SPECIFICATIONS AND APPROVED PLANS.
B. CRITERIA
1 . CONTRACTOR SHALL VERIFY WITH THE LANDLORD'S REPRESENTATIVE
FOR ANY ADDITIONAL CRITERIA (PIPE SIZING; PIPE SCHEDULE OR
HYDRAULIC).
2. DE51GN AND INSTALL THE SPRINKLER SYSTEM AND PIPING TO
CONFORM WITH NFPA 13, ORDINARY HAZARD DE51GN WITH A
MAXIMUM SPACING OF 130 SQUARE FEET PER SPRINKLER HEAD IN
SALES AREAS AND 100 SQUARE FEET PER HEAD IN STOCK AREAS.
3. THE FROJECT AREA CURRENTLY HAS AN EXISTING SPRINKLER SYSTEM
INSTALLED WITH FLUSH SPRINKLER HEADS INSTALLED ON A STANDARD
GRID PATTERN. CONTRACTOR SHALL DE51GN AND MODIFY THE
EXISTING SPRINKLER SYSTEM PIPING AND HEADS. THI5 WORK SHALL
INCLUDE THE RAISING OF ANY EXISTING SPRINKLER PIPING WHICH
INTERFERES WITH DE51GNED CEILING ELEVATIONS. SEE ARCH.
DRAWINGS FOR CEILING ELEVATIONS. PROVIDE ANY AUXILIARY DRAIN
PIPING REQUIRED FOR ANY TRAPPED SPRINKLER PIPING.
4. SEE ARCH. DRAWINGS FOR CEILING ELEVATION5.
C. COMPONENTS
I . PROVIDE A WATTS REGULATOR NO. (007 -LF 3/4 TO 2.5" 009 2" TO I 0")
DOUBLE CHECK VALVE ASSEMBLY BACKFLOW PREVENTER IN THE PIPING
TO THE SPRINKLER HEADS IMMEDIATELY FOLLOWING THE CONNECTION
TO THE DOMESTIC WATER SYSTEM.
2. FIRE DEPARTMENT CONNECTION: POTTER-ROEMER OR EQUAL SERIES
5020, 4 x 2%2 x 2%2, WITH ALL STANDARD FEATURES, "AUTO. 5PKR."
LETTERING, AND THREAD TO MATCH LOCAL FIRE DEPARTMENT
REQUIREMENTS. - FLUSH MOUNTED FIRE DEPARTMENT INLET
CONNECTION WITH WALL PLATE WITH "AUTOMATIC SPRINKLER'
IDENTIFICATION, ALL BRASS CONSTRUCTION AND POLISHED BRASS
FINISH. CONTACT THE FIRE DEPARTMENT TO VERIFY FIRE DEPARTMENT
CONNECTION TYPE AND TREAD PATTERN TO MATCH THAT OF THE FIRE
DEPARTMENT EQUIPMENT. PROVIDE 4" UL LISTED CHECK VALVE WITH
BALL DRIP PIPED TO DRAIN.
D. SUPERVISION:
I. THE RISER CONTROL VALVE AND ALL ZONE VALVES SHALL HAVE
ELECTRIC SUPER VISION TO SIGNAL THE BUILDING FIRE ALARM SYSTEM.
TAMPER SWITCHES PROVIDED BY SPRINKLER SUBCONTRACTOR AND
WIRED BY THE ELECTRICAL SUBCONTRACTOR.
2. MECHANICAL: ALL OTHER VALVES SHALL BE PADLOCKED IN STANDARD
OPERATING POSITION, WITH 2 KEYS PER PADLOCK AND ALL PADLOCKS
SHALL BE KEYED THE SAME. CHAIN AND PADLOCK ALL VALVES OVER 2"
SIZE.
E. PIPING
1 . PIPING SHALL BE BLACK STEEL PIPE PER NFPA 13.
2. PIPE HANGERS FOR THE SPRINKLER SYSTEM SHALL BE ADJUSTABLE
CLEVIS HANGERS WITH APPROPRIATE CLAMP (DEPENDING ON
STRUCTURE). ALL PIPING SHALL BE SUPPORTED ON A MAXIMUM OF I O'
CENTERS.
F. SPRINKLER HEADS
I. SPRINKLER HEADS IN AREAS WITH CEILINGS SHALL BE CENTRAL
SPRINKLER CORP, DIVISION OF TYCO. SERIES TY -L, %2" ORIFICE,
RECESSED, POLISHED CHROME PENDANT AUTOMATIC SPRINKLER HEAD
WITH TWO PIECE FACTORY WHITE METAL ESCUTCHEON.
2. SPRINKLER HEADS IN AREAS WITH DRYWALL CEILINGS SHALL BE
CENTRAL SPRINKLER CORP, DIVISION OF TYCO. ROYAL FLUSH II SERIES
RFII, I G5 F, WITH A WHITE CEILING PLATE.
3. SPRINKLER HEADS IN AREAS WITH EXPOSED STRUCTURE SHALL BE
BRASS UPRIGHT CENTRAL SPRINKLER CORP. DIVISION OF TYCO SERIES
TY -L, %2" ORIFICE, I G5 F.
IV. PLUMBING
A. GENERAL
I. THE ENTIRE PLUMBING INSTALLATION, MATERIALS, EQUIPMENT, ETC.
SHALL CONFORM TO THE REQUIREMENTS OF THE LOCALLY ENFORCED
BUILDING CODE, THE PLUMBING CODE, THE AMERICAN DISABILITIES
ACT GUIDELINES, AN51 A 117. I REQUIREMENTS FOR THE PHYSICALLY
CHALLENGED AND THE UNIFORM FEDERAL ACCESSIBILITY STANDARDS
(UFA5). CONTRACTOR TO VERIFY ALL PLUMBING ROUGH IN
DIMENSIONS MEET THE ABOVE NOTED REQUIREMENTS. VERIFY FINAL
ROUGH IN WITH ARCHITECT PRIOR TO BACKFILLING OR WALL
INSTALLATION.
2. TEST ALL SEWER AND WATER PIPING IN ACCORDANCE WITH LOCAL
CODES AND ORDINANCES.
3. FURNISH ACCESS DOORS FOR WALL CLEAN OUTS AND VALVES IN
WALLS.
4. ALL FIXTURES AND EQUIPMENT NOT SPECIFIED HERE -IN ARE BEING
PROVIDED BY OTHERS. THI5 CONTRACTOR SHALL BE RESPONSIBLE
FOR ROUGHING IN ALL SERVICES FOR ALL EQUIPMENT WHETHER
PROVIDED BY THIS CONTRACTOR OR OTHERS. CONTRACTOR SHALL
COORDINATE HIS INSTALLATION WITH THE APPROPRIATE EQUIPMENT
SUPPLIER FOR PROPER ROUGH IN INFORMATION AND SHALL REVISE
THE DE51GN AS REQUIRED TO MATCH THE EQUIPMENT BEING SUPPLIED.
THI5 CONTRACTOR SHALL PROVIDE ALL LABOR AND MATERIALS
REQUIRED TO CONNECT ALL FIXTURES TO THE PLUMBING SYSTEMS
INCLUDING BUT NOT LIMITED TO; ALL WATER OR NATURAL GAS
CONNECTIONS FROM APPROPRIATE STOP OR VALVE, ALL DIRECT
SANITARY CONNECTIONS, ALL INDIRECT WASTE CONNECTIONS TO
FLOOR DRAINS OR SINKS FROM SINKS OR EQUIPMENT, COOLER AND
FREEZER COIL CONDENSATE DRAIN PIPING, ETC.
5. FIRE STOPPING - REFER TO ARCHITECTURAL DRAWINGS FOR WALL TYPE
AND UL CONSTRUCTION DESIGN NUMBER. FOR RATED MASONRY WALL
AND FLOOR ASSEMBLIES, PROVIDE A UL APPROVED
THROUGH -PENETRATION FIRE STOP SYSTEM NUMBER C -AJ -1 175. FOR
RATED GYPSUM BOARD ASSEMBLIES, PROVIDE A UL APPROVED
THROUGH -PENETRATION FIRE STOP SYSTEM NUMBER W -L-1003.
B. PIPING
1 . PIPE HANGERS FOR THE PLUMBING SYSTEM SHALL BE ADJUSTABLE
CLEVIS HANGERS WITH APPROPRIATE CLAMP. ALL PIPING SHALL BE
SUPPORTED ON A MAXIMUM SPACING OF:
a. G' CENTERS FOR PIPING 3/4" AND SMALLER.
b. 8' CENTERS FOR I " PIPING.
c. I O' CENTERS FOR PIPING LARGER THAN I ".
d. PIPING ABOVE THE ROOF SHALL BE SUPPORTED PER THE DETAIL
ON THE DRAWINGS.
e. PIPE HANGERS FOR INSULATED PIPING SYSTEMS SHALL BE 51ZED
FOR THE GROSS OUTSIDE DIMENSION OF THE PIPE AND
INSULATION. SEE INSULATION SPECIFICATIONS FOR INSULATION
REQUIREMENTS.
C. SANITARY AND VENT
1 . ALL PIPING SHALL PITCH TO IT'S APPROPRIATE MAIN AT NO LE55 THAN
I /8" PER FOOT SLOPE.
2. UNDERGROUND WASTE AND VENT PIPING SHALL BE SERVICE WEIGHT
CAST IRON HUB AND SPIGOT PIPE WITH COMPRESSION GASKET JOINTS
OR SCHEDULE 40 DWV PVC PIPING AND FITTING5 WITH SOLVENT
WELDED JOINTS.
3. ABOVE GROUND WASTE AND VENT PIPING SHALL BE SERVICE WEIGHT
CAST IRON NO -HUB PIPE WITH STAINLESS STEEL BANDED JOINTS AND
BE HUNG PER C.I.5.P.1. REQUIREMENTS OR SCHEDULE 40 DWV PVC
PIPING AND FITTINGS WITH SOLVENT WELDED JOINTS.
a. PVC PIPING SHALL NOT BE INSTALLED IN A RETURN AIR PLENUM.
D. DOMESTIC WATER
I. CONTRACTOR SHALL COORDINATE WITH THE BUILDING TENANT AND
THE LOCAL WATER COMPANY FOR THE INSTALLATION OF A NEW WATER
METER. THI5 SHALL INCLUDE THE FEES/COSTS AND INSTALLATION OF A
NEW WATER METER AS SHOWN ON THE PLANS AND THE ASSOCIATED
REMOTE READER. THE ENTIRE INSTALLATION SHALL CONFORM TO THE
REQUIREMENTS OF THE LOCAL WATER COMPANY. LOCATE REMOTE
READER AT BUILDING TENANT'S AND WATER COMPANY'S DIRECTION.
2. TEST WATER PIPING TO HYDROSTATIC PRESSURE OF 100 PSIG. FOR
TWO HOURS. STERILIZE ALL DOMESTIC WATER PIPING IN ACCORDANCE
WITH A.W.W.A. STANDARDS.
3. ABOVE GROUND WATER PIPING, 3" AND SMALLER, SHALL BE TYPE "L"
HARD DRAWN COPPER PIPE WITH WROUGHT COPPER FITTINGS AND
95-5 SOLDERED JOINTS. AS AN ALTERNATE THE CONTRACTOR MAY
UTILIZE COPPER PRESS FITTINGS (PROPRE55 SYSTEM) AS
MANUFACTURED BY VIEGA. FITTINGS SHALL CONFORM TO THE
MATERIAL AND SIZING REQUIREMENTS OF A5ME B 1 G. 1 8 OR A51VE
B I G.22. O -RINGS FOR FITTINGS SHALL BE EDPM. INSTALLATION OF
FITTINGS SHALL CONFORM TO CODE AND THE MANUFACTURERS
SPECIFICATIONS/REQUIREMENTS. WATER PIPING JOINTS BETWEEN
DIFFERENT MATERIALS SHALL BE PER THE LOCALLY ENFORCED
PLUMBING CODE SECTION 605.22.
4. DOMESTIC WATER VALVES SHALL BE MILWAUKEE VALVE #BA- 100 OR
#BA- 1 50 BALL VALVE
E. NATURAL GAS SYSTEMS (WHERE APPLICABLE TO PROJECT SCOPE)
I. GENERAL
a. CONTRACTOR SHALL COORDINATE WITH THE LOCAL GAS COMPANY
TO PROVIDE A NEW GAS METER. THE ENTIRE INSTALLATION SHALL
CONFORM TO THE GAS COMPANY REQUIREMENTS. ALL FEES
AND/OR COSTS ASSOCIATED WITH THE GAS SERVICE AND METER
SHALL BE PAID BY THE CONTRACTOR.
2. PIPING
a. NATURAL GAS PIPING MATERIAL, JOINTS AND INSTALLATION SHALL
MEET THE REQUIREMENTS OF THE LOCALLY ENFORCED INTERNATIONAL
FUEL AND GAS CODE, THE UTILITY COMPANY REQUIREMENTS AND ANY
OTHER AUTHORITIES HAVING JURISDICTION.
b. ALL ELEVATION CHANGES AND CONNECTIONS TO EQUIPMENT SHALL
HAVE A G" DEEP DRIP LEG.
c. PROVIDE A FULL SIZE GAS SHUT-OFF VALVE AND GROUND JOINT
UNION AT ALL CONNECTIONS TO GAS FIRED EQUIPMENT.
d. IN NO CASE MAY A VALVE BE INSTALLED IN A RETURN AIR PLENUM.
e. UNDERGROUND NATURAL GAS PIPING SHALL BE 8100 HIGH DENSITY
POLYETHYLENE AS MANUFACTURED BY PHILLIPS DRISCOPIPE CO. AND
AS APPROVED BY GAS COMPANY. PIPING SHALL BE INSTALLED PER
GAS COMPANY AND MANUFACTURERS REQUIREMENTS.
f. ABOVEGROUND NATURAL GAS PIPING SHALL BE:
(1) 2" AND SMALLER: SCHEDULE 40 BLACK STEEL PIPE WITH THREAD
JOINTS AND MALLEABLE IRON FITTINGS.
(2) 2-1 /2" AND LARGER: SCHEDULE 40 BLACK STEEL PIPE WITH
WROUGHT STEEL BUTTWELD FITTINGS.
g. GAS SHUT-OFF VALVES SHALL BE:
(1) I AND SMALLER: 1 25 LB. IRON BODY WITH BRONZE PLUG
WASHER. CRANE # 320 OR HOMESTEAD # GO 1 .
(2) 1- 1 /4" AND LARGER: LUBRICATED PLUG COCK. NORD5TRUM # 142
OR HOMESTEAD #GO2.
(3) OR APPROVED EQUAL VALVES BY NIBCO, LUNKENHEIMER,
5TOCKHAM OR POWELL.
h. THE TRANSITION RISER FROM UNDERGROUND PLASTIC GAS PIPING TO
THE ABOVE GROUND STEEL GAS PIPING SHALL BE AS MANUFACTURED
BY PERFECTION CORP. OF MADISON, OHIO. INSTALLATION SHALL
CONFORM TO GAS COMPANY AND MANUFACTURER'S REQUIREMENTS.
V. HVAC EQUIPMENT (NOTE, ALL EQUIPMENT LISTED MAY NOT PERTAIN TO THI5
PROJECT. REFER TO DRAWINGS FOR NEW EQUIPMENT AND EXISTING TO REMAIN).
A. INSTALLATION OF ALL EQUIPMENT SHALL COMPLY WITH THE
MANUFACTURERS INSTALLATION INFORMATION AND INSTRUCTIONS,
REQUIREMENTS AND ANY ADDITIONAL GUIDELINES. CONTRACTOR SHALL
PROVIDE ALL ADDITIONAL REQUIRED ACCESSORIES REQUIRED TO
COMPLETE THE INSTALLATIONS.
B. HVAC EQUIPMENT SrIALL DE "5TARTED UP" BY A i=AC OKY TRAINCD AND
AUTHORIZED SERVICE TECHNICIAN. ALL FACTORY STARTUP FORMS
SHALL BE COMPLETED AND TURNED OVERTO THE TENANT WITH ALL
COMPLETED WARRANTY CARDS PRIOR TO FINAL APPROVAL.
C. PACKAGE ROOFTOP HEATING AND AIR-CONDITIONING UNITS
I . UNIT SHALL BE OF ONE-PIECE PACKAGED CONSTRUCTION COMPLETE12
ASSEMBLED, WIRED AND FACTORY TESTED.
2. CABINET SHALL BE DESIGNED FOR FULL ROOF CURB SUPPLY AND
RETURN DESIGNED TO MATE AND SEAL WITH THE ROOF CURB, BAKED
ENAMEL FINISH, HINGED ACCESS PANELS SHALL BE PROVIDED WITH
QUICK RELEASE FASTENERS AND HANDLES. ALL INTERIOR SURFACES
SHALL BE COMPLETELY INSULATED WITH FOIL, VINYL OR
NEOPRENE -BACKED INSULATION.
3. WIRING SHALL COMPLY WITH LATEST EDITION OF THE NEC AND SHALL
INCORPORATE 3 -LEG OVERLOAD PROTECTION FOR THE
COM PRE55OR(5).
4. EVAPORATOR FANS SHALL BE BELT DRIVEN WITH ADJUSTABLE SHEAVES
OR MULTI SPEED, FIELD ADJUSTABLE.
5. UNIT SHALL BE COMPLETE WITH PRESSURE SAFETY CONTROLS,
ANTI -SHORT CYCLE PROTECTION, AND FACTORY FURNISHED
ECONOMIZER DAMPERS, INTAKE HOODS, HAIL GUARDS AND CONTROLS
(WHEN SPECIFICALLY NOTED ON THE DRAWINGS).
G. SEE DRAWING FOR INDIV DUAL UNIT PERFORMANCE REQUIREMENTS.
D. ROOF MOUNTED DOWNBLA5T EXHAUST VENTILATOR.
I . ALL ALUMINUM HOUSING WITH BACKWARD -INCLINED ALUMINUM WHEEL.
HINGED BASE, 14 -INCH ROOF CURB, BACKDRAFT DAMPER AND
BIRD5CREEN.
2. DIRECT DRIVE MOTOR WITH PERMANENTLY LUBRICATED BEARINGS,
WITH PREWIRED FAN SPEED CONTROLLER.
3. PROVIDE WITH PRE -WIRED STANDARD DISCONNECT
A PFFFR T(l nr2AlA/INI(- FnP FANI PFr2F(>12NAANI('F ANIn �171N1(; nATA
VI. AIR DISTRIBUTION
A. AIR DISTRIBUTION
I . DUCTWORK (ROUND OR RECTANGULAR OR SPIRAL) SHALL BE OF
GALVANIZED STEEL CONSTRUCTION AND SHALL BE INSTALLED IN
ACCORDANCE WITH THE LATEST EDITION OF THE 5MACNA MANUAL AND
THE FOLLOWING PRESSURE/ SEAL SCHEDULE:
a. DUCTWORK BETWEEN AHU (ROOFTOP UNIT) AND VAV BOXES - 3"
W.G. POSITIVE PRESSURE, EAL CLA55 A.
b. OTHER SUPPLY AIR DUCTWORK - 2" W.G. POSITIVE PRESSURE, SEAL
C LASS B.
c. RETURN 4 EXHAUST DUCTWORK - 2" W.G. NEGATIVE PRESSURE, SEAL
CLASS B.
2. ROUND DUCT ELBOWS SHALL BE LONG SWEEP, I -1 /2 TIMES THE
CENTERLINE RADIUS UNLESS CLEARANCE IS NOT AVAILABLE AT WHICH
TIME MITERED ELBOWS WITH TURNING VANES SHALL BE UTILIZED.
3. RECTANGULAR ELBOWS SHALL BE FURNISHED WITH DOUBLE THICKNESS
TURNING VANES. TURNING VANES SHALL BE FASTENED WITH A DOUBLE
ROW OF SCREWS.
4. FLEXIBLE CONNECTIONS AT THE INLET AND OUTLET OF THE RTU. INSTALL
FLEXIBLE CONNECTIONS WITH 3" WIDE DOUBLE NEOPRENE COATED
FLAME RETARDANT, NFPA 90A APPROVED, FIBERGLASS FLEXIBLE
CONNECTION. FLEXIBLE CONNECTION TO HAVE A MINIMUM OF 24 GAGE
3" WIDE SHEET METAL COLLARS PERMANENTLY ATTACHED TO EACH SIDE.
5. MITERED OFFSETS GREATER THAN 30 DEGREES IN EITHER DIRECTION
SHALL NOT BE PERMITTED.
G. CHANGES IN DUCT SIZES SHALL BE MADE BY UNIFORM TAPER SECTION
WITH A MAXIMUM INCLUDE ANGLE OF DIVERGENCE OF 1 5DEGREE5.
7. RECTANGULAR BALANCING DAMPERS - RUSKIN MD25 SHALL BE SINGLE
BLADE UP TO G" IN HEIGHT AND 3G" IN WIDTH, AND RUSKIN MD35
MULTI -BLADE FOR LARGER SIZES. ALL ROUND BALANCING DAMPERS
SHALL BE COMMERCIAL GRADE SINGLE BLADE UP TO I G" IN DIAMETER
SHALL INCORPORATE LOCKING TYPE INDICATING ADJUSTMENT.
BALANCING DAMPERS SHALL BE INSTALLED IN ALL BRANCH DUCTS OFF
MAIN AND ON ALL TAPS OFF DUCTS TO DIFFUSERS UNLESS OTHERWISE
NOTED ON DRAWINGS.
8. FINAL CONNECTIONS TO DIFFUSERS MAY BE MADE WITH FLEXIBLE
DUCTWORK BUT IT'S USE IS LIMITED TO STRAIGHT HORIZONTAL OR
VERTICAL RUNS. ALL CHANGES OF DIRECTION IN AN DUCT SYSTEM
(GALVANIZED OR FLEXIBLE) SHALL BE MADE WITH AN APPROPRIATE
GALVANIZED ELBOW. MAXIMUM LENGTH OF ANY FLEXIBLE DUCT I5 5'-0"
9. FLEXIBLE DUCTS TO DIFFUSERS SHALL BE ATCO RUBBER PRODUCTS,
INC. MODEL UPC #070, INSULATED (R=4.2), U.L. 18 I RATED AND
CLA55 I AIR CONNECTOR. MAXIMUM LENGTH OF FLEXIBLE DUCT TO
DIFFUSER TO BE 5'-0".
10. FIRE DAMPERS SHALL BE RUSKIN AND SHALL BE INSTALLED PER
MANUFACTURERS INSTRUCTIONS AND SMACNA REQUIREMENTS FOR A
U.L. APPROVED INSTALLATION. FIRE DAMPERS SHALL BE TYPE "B"
(BLADES AND FRAME COMPLETELY OUT OF THE AIRSTREAM) FOR ALL
WALL ASSEMBLIES AND SHALL BE INSTALLED WITH THE APPROPRIATE
WALL SLEEVE AND ANGLES PER UL 555. FIRE DAMPERS SHALL BE
INSTALLED IN ALL FIRE RATED WALLS. VERIFY FIRE RATED WALL
LOCATIONS AND RATINGS ON THE ARCHITECTURAL DOCUMENTS. FOR
ALL FLOOR PENETRATIONS PROVIDE RUSKIN TYPE "LR" FIRE DAMPERS.
SEE DETAILS ON DRAWINGS FOR ADDITIONAL INSTALLATION
REQUIREMENTS.
I 1 . DOUBLE THICKNESS INSULATED ACCESS DOORS SHALL BE PROVIDED AT
ALL FIRE DAMPERS FOR ACCESS TO FUSIBLE LINK. DOOR SHALL BE
SIZED TO ALLOW FOR EASY SERVICE AND ACCESSIBILITY. ACCESS
DOORS SHALL BE A MINIMUM OF 24" IN THE LONGEST DIMENSION.
1 2. PROVIDE 3"x3"x 1 /4" ANGLE FRAMING AROUND THE ROOF OPENINGS FOR
THE SUPPLY AND RETURN AIR DUCTWORK.
13. SUPPORT ALL SHEET METAL AND EQUIPMENT FROM ANGLE IRON
CONNECTED TO STRUCTURAL STEEL. DO NOT SUSPEND DUCT OR
EQUIPMENT FROM METAL DECK OR JOIST BRIDGING.
VII. CONTROLS
A. CONTROL WIRING SHALL BE PLENUM RATED CABLE WITH COLOR CODED
18 AWG WIRES (MINIMUM).
B. CONTRACTOR SHALL PROVIDE ALL WIRING BETWEEN THERMOSTAT AND
EQUIPMENT (AIR HANDLER, ROOFTOP UNIT, CONDENSING UNIT, ETC.).
C. CONTRACTOR SHALL FURNISH AND INSTALL A 1 20 (24) VOLT SUPPLY AIR
DUCT MOUNTED IONIZATION SMOKE DETECTOR. DETECTOR SHALL BE
WIRED, BY THE ELECTRICAL (CONTROLS) CONTRACTOR, TO SHUT DOWN
UNIT UPON ACTIVATION.
D. THERMOSTATS
I. FURNISH AND INSTALL A HONEYWELL 7 DAY PROGRAMMABLE
HEATING/COOLING THERMOSTAT AND CLEAR LOCKABLE COVER WITH
APPROPRIATE CONTROL WIRING BETWEEN THERMOSTAT, (FURNACE AND
CONDENSING UNIT) ( ROOFTOP) AS REQUIRED TO PROVIDE A
COMPLETE OPERATING SYSTEM. WIRING SHALL BE MINIMUM 18 AWG.
2. THERMOSTATS SHALL BE MOUNTED WHERE INDICATED ON THE
DOCUMENTS.
3. CONTRACTOR SHALL PROGRAM THERMOSTAT PER THE TENANT'S
REQUIREMENTS AND TRAIN TENANT'S PERSONNEL IN THE OPERATION
AND PROGRAMMING OF THE THERMOSTAT AND SYSTEM.
VIII. TESTING AND BALANCING
A. TESTING AND BALANCING SHALL NOT BEGIN UNTIL THE SYSTEM HAS BEEN
COMPLETED, I5 IN FULL WORKING ORDER AND ALL EQUIPMENT START-UP
HAS BEEN COMPLETED. ALL HVAC SYSTEMS AND EQUIPMENT SHALL BE
PUT INTO FULL OPERATION AND THE OPERATION OF SAME CONTINUED
DURING EACH WORKING DAY OF THE TESTING AND BALANCING.
B. AN INDEPENDENT "AABC" OR "NEBB" CERTIFIED AIR AND WATER BALANCE
CON FRACTOP. SHALL TEST AND BALANCE THE SYSTEM AND REPORT
RESULTS TO THE ENGINEER TENANT AND THE LANDLORD.
I . ALL WORK 5HALL BE DONE UNDER DIRECT 5U1'I KVI510N OF THE
CERTIFIED BALANCING ENGINEER AND BY QUALIFIED BALANCING
TECHNICIANS.
2. METHODS AND FORMS SHALL BE IN ACCORDANCE WITH THE
CERTIFICATION AGENCIES RECOMMENDATIONS AND REQUIREMENTS.
3. COMPLY WITH A5HRAE RECOMMENDATIONS PERTAINING TO
MEASUREMENTS, INSTRUMENTS, TESTING, ADJUSTING AND BALANCING.
4. ALL QUANTITIES SHALL BE WITHIN 10% OF T11E DESIGN VALUES.
5. CONTRACTOR SHALL PROVIDE ANY SHEAVE CHANGES REQUIRED ON
THE HVAC UNIT.
C. PERFORMANCE TEST
I . AFTER ALL HVAC EQUIPMENT IS INSTALLED, TESTED AND BALANCED AS
SPECIFIED HEREIN THEY SHALL BE OPERATED AND PLACED UNDER
SURVEILLANCE FOR A PERIOD OF AT LEAST ONE (1) DAY, THIS MAY
INCLUDE THE DAY OF STARTUP, TO VERIFY THAT ALL EQUIPMENT i5
PRODUCING THE REQUIRED CAPACITY. THE HVAC CONTRACTOR SHALL
BE RESPONSIBLE FOR THE OPERATION OF THE EQUIPMENT DURING THE
ENTIRE PERIOD.
2. TEST SHALL BE PERFORMED WITH ALL CONTROLS IN THE AUTOMATIC
POSITION AND BUILDING LIGHTS, DAMPERS, ETC. POSITIONED TO
SIMULATE NORMAL OPERATION OF THE HVAC SYSTEM.
3. DURING THE TEST, CONTROL 5ETFING5 MAY REQUIRE ADDITIONAL
ADJUSTMENTS TO PRODUCE THE BEST BALANCED SYSTEM OPERATION.
THEIR FINAL SETTING- OF EACH OPERATING AND SAFETY CONTROL
SHALL BE RECORDED, THEY SHALL INCLUDE, BUT NOT LIMITED TO,
THERMOSTATS, LIMIT CONTROLS, AND OTHER SIMILAR ITEMS.
4. SHOULD COMPLETION OF THE INSTALLATION OCCUR AT SUCH TIME
THAT THE REQUIRED PERFORMANCE TEST MUST BE CONDUCTED
DURING A SEASON WHEN THE FULL OPERATION OF EITHER THE HEATING
OR COOLING SYSTEM CAN NOT BE CHECKED, THE CONTRACTOR SHALL
PERFORM THE TEST AND RECORD ALL SUCH DATA AS I5 AVAILABLE
WITH SYSTEM OPERATING AUTOMATICALLY UNDER THE PREVAILING
WEATHER CONDITIONS. THAT PART OF THE SYSTEM WHICH CAN NOT
BE TESTED SHALL BE DELAYED UNTIL THE WEATHER IS APPROPRIATE, AT
WHICH TIME THE REMAINING PART OF THE REQUIRED TESTS SHALL BE
CONDUCTED AND DATA RECORDED ACCORDINGLY.
D. ACCEPTANCE AND CHECK-OUT - CONTRACTOR SHALL PROVIDE QUALIFIED
PERSONNEL, AT NO ADDITIONAL COST TO THE TENANT, AS MAY BE
REQUIRED BY THE ENGINEER FOR THE PURPOSE OF VERIFYING PROPER
OPERATION AND INSTALLATION OF THEIR WORK AT THE TIME OF REQUEST
FOR ACCEPTANCE.
ELECTRICAL 5PECIEICATION5
DIV15ION I G - ELECTRICAL
I. FART I - GENERAL
A. DESCRIPTION OF WORK
1. THE ELECTRICAL CONTRACTOR SHALL PROVIDE ALL LABOR, MATERIAL,
EQUIPMENT AND TOOLS NECESSARY TO COMPLETE THE ELECTRICAL
WORK AS SHOWN ON THE DRAWINGS OR SPECIFIED HEREIN.
2. THE ELECTRICAL WORK SHALL BE INSTALLED IN ACCORDANCE WITH ALL
PROVISIONS OF THE NATIONAL ELECTRICAL CODE (NFPA 70), AS WELL AS ANY
MODIFICATIONS OR REGULATIONS PUBLISHED BY LOCAL OR STATE AUTHORITIES
THE ELECTRICAL WORK SHALL ALSO BE INSTALLED IN ACCORDANCE WITH THE
PROVISIONS OF THE LATEST EDITIONS OF THE STATE BUILDING CODE, NFPA 7 1 ,
NFPA 101 AND THE AMERICANS WITH DISABILITIES ACT WHERE APPLICABLE.
3. ELECTRICAL, MECHANICAL, ARCHITECTURAL, STRUCTURAL, AND ALL
OTHER DRAWINGS, AS WELL AS SPECIFICATIONS AND ADDENDUM5 SHALL
BE PART OF THE CONTRACT DOCUMENTS.
4. EQUIPMENT AND MATERIALS USED ON THI5 PROJECT SHALL BE NEW, U.L.
LABELED AND MEET 05HA REQUIREMENTS. EQUIPMENT AND MATERIAL
SHALL BE PROTECTED AND 5HALL BE THE RESPONSIBILITY OF THIS
CONTRACTOR UNTIL FORMALLY ACCEPTED BYTHE TENANT.
5. TEMPORARY ELECTRICAL SERVICE, LIGHTING, AND RELATED WIRING SHALL BE
PROVIDED TO 05HA REQUIREMENTS FOR THE USE OF ALL TRADES DURING
CONSTRUCTION.
6. PROVIDE ALL CUTTING AND PATCHING REQUIRED FOR INSTALLATION OF
ELECTRICAL WORK. ALL CORE DRILLING OR CUTTING OF FIRE RATED
FLOORS, SHAFTS AND WALLS SHALL BE FIRE STOPPED PRIOR TO FINISH
PATCHING. ALL PENETRATIONS SHALL BE FIRE SEALED TO MATCH THE FIRE
RATING OF THE FLOORS, SHAFTS OR WALL5 PENETRATED.
7. TEMPERATURE AND INTERLOCK CONTROL COMPONENTS AND ALL RELATED
CONDUIT AND WIRING SHALL BE PROVIDED BYTHE MECHANICAL
CONTRACTOR UNLESS OTHERWISE INDICATED ON THE DRAWINGS.
8. THE GENERAL CONTRACTOR SHALL VERIFY SITE LIGHTING BASE DETAILS
WITH STRUCTURAL ENGINEER TO VERIFY APPLICABILITY WITH POLE/FIXTURE
Aron (YlNiniTlrlNi4
B. PERMITS AND FEES
1. THE ELECTRICAL CONTRACTOR SHALL SECURE AND PAY FOR LOCAL AND/OR STATE
PERMITS AND INSPECTION FEES REQUIRED FOR THE ELECTRICAL WORK.
C. GROUNDING
1. GROUND ALL CONDUITS, CABINETS, MOTORS, PANELS, AND OTHER EXPOSED
NON-CURRENT CARRYING METAL PARTS OF ELECTRICAL EQUIPMENT IN
ACCORDANCE WITH THE NATIONAL ELECTRICAL CODE ARTICLE 250.
2. GROUNDING OF THE ELECTRICAL SYSTEM SHALL BE BY MEANS OF AN
INSULATED GROUNDING CONDUCTOR INSTALLED WITH ALL FEEDERS AND
BRANCH CIRCUIT CONDUCTORS IN ALL CONDUITS.
D. TESTS
1. TEST FOR GROUNDS, SHORT CIRCUITS, AND PROPER FUNCTION OF ALL
EQUIPMENT AFTER INSTALLATION I5 COMPLETE. FAULTS IN THE INSTALLATION
SHALL BE CORRECTED AT NO COST TO THE TENANT.
E. DEMOLITION
DEMOLIT ON F EXIST
1. I O LNG ELECTRICAL EQUIPMENT IF APPLICABLE SHALL BE PA T
R
OF THE ELECTRICAL WO A N N T WINGS.
RK S I DILATED O HE DRA
F. GUARANTEES
1. GUARANTEE FOR ONE YEAR AFTER ACCEPTANCE BY TENANT, ALL WORKMANSHIP
AND MATERIALS FURNISHED.
II. PART 2 - FRODUCT5
A. CONDUIT
1. CONDUIT SHALL BE HEAVY WALL RIGID GALVANIZED STEEL WHERE EXPOSED AND
SUBJECT TO DAMAGE, 8'-O" AFF AND BELOW, AND IN WET LOCATIONS WHERE
INDICATED ON THE DRAWINGS. UNDERGROUND CONDUIT SHALL BE SCHEDULE 40
PVC AND SHALL BE CONCRETE ENCASED (3' MINIMUM) WHERE INDICATED ON THE
DRAWINGS. A TRANSITION SHALL BE MADE TO HEAVY WALL RIGID GALVANIZED
STEEL BEFORE PVC CONDUITS PENETRATE THE FLOOR SLAB. INTERIOR CONDUITS
SHALL BE ELECTRICAL METALLIC TUBING (EMT). METAL CLAD (MC) CABLE MAY BE
USED IF APPROVED BY THE TENANT, AND INSTALLED IN LOCATIONS PERMITTED BY
CODE.
2. FLEXIBLE METAL CONDUIT SHALL BE USED FROM OUTLET BOX TO INDIVIDUAL
RECESSED LIGHT FIXTURES, AND FOR FINAL CONNECTIONS TO MOTORS AND
OTHER DEVICES SUBJECT TO VIBRATION.
3. SURFACE METAL RACEWAY SHALL BE WIREMOLD #G-3000 SERIES OR APPROVED
EQUAL, GRAY. USED AT PA55 THRU. LENGTH AS CALLED OUT ON PLAN. INCLUDES ALL
ACCESSORIES.
B. CONDUIT FITTINGS AND BOXES
1. INTERIOR OUTLET BOXES SHALL BE STANDARD GALVANIZED SHEET STEEL TYPE, NOT
LESS THAN 14 GAUGE IN THICKNESS, WITH KNOCKOUT OPENINGS, EXTENSIONS,
PLASTER RINGS AND COVER PLATES TO ACCOMMODATE THE DEVICES INSTALLED.
COVER PLATES SHALL BE SMOOTH PLASTIC TO MATCH DEVICE COLOR. USE STEEL
PLATES WITH ROUNDED CORNERS FOR SURFACE BOXES. OUTDOOR (WET LOCATION)
OUTLET BOXES SHALL BE CAST ALUMINUM TYPE WITH DEVICE COVERS TO SUIT.
2. OUTLET BOXES SHALL NOT BE LE55 THAN 4 INCHES SQUARE, I -1 /2 INCHES DEEP.
3. COUPLINGS AND CONNECTORS FOR EMT SHALL BE DIE CAST ZINC OR STEEL.
BUSHING SHALL BE GROUNDING TYPE WITH INSULATING PLASTIC INSERT.
4. FLOOR JUNCTION BOX WITH COVER SHALL BE HUBBELL #82527 BRASS STEEL DEEP
BOX WITH #52525 BRASS STEEL COVER OR APPROVED EQUAL. USED AT D3 LF- I
CASEWORK AND FUTURE MILLWORK/CASEWORK.
5. ALL COVER PLATE FOR OUTLETS, SWITCHES AND RECEPTACLES SHALL BE WHITE.
C. WIRE AND CABLE
1. CONDUCTORS FOR POWER AND LIGHTING SHALL BE NEW GOO -VOLT, 90 C, TYPE
XHHW, THHN, OR THWN INSULATION, MINIMUM SIZE # 12 -AWG, EXCEPT FOR CONTROL
WIRING WHICH MAY BE # 14 -AWG. OTHER SIZES SHALL BE AS NOTED ON THE
DRAWINGS. CONDUCTORS SHALL BE COPPER, UNLESS OTHERWISE APPROVED BY THE
TENANT.
2. BRANCH CIRCUIT RUNS EXCEEDING 100 FEET IN TOTAL LENGTH FROM THE
PANELBOARD TO THE LAST DEVICE, SHALL BE #1 O -AWG CONDUCTORS UNLESS
OTHERWISE NOTED.
3. COMPRESSION TYPE LUGS AND CONNECTORS SHALL BE USED FOR ALL
TERMINATIONS AND SPLICES.
4. ALL LOW VOLTAGE COMMUNICATIONS, FIRE ALARM, DATA, SECURITY, TELEPHONE AND
ALL OTHER MISCELLANEOUS LOW VOLTAGE WIRING INSTALLED IN CEILING SHALL BE
PLENUM RATED.
5. TELEPHONE WIRING SHALL BE 4 PAIR 22/24 AWG (PLENUM RATED). MANUFACTURER
SELECTED BY EC.
6. DATA (EYENET-PGS) WIRING SHALL BE BERK-TEK PART # 10032207, CATEGORY 5E OR
4. PAIR UTP (PLENUM RATED). PROVIDE G' OF EXCESS CABLE AT CA5HWRAP AND 3' OF
CABLE AT THE PHONEBOARD AND OTHER LOCATIONS. TENANT VENDOR TO PERFORM
PUNCHDOWN AND SYSTEMS VERIFICATION.
D. WIRiNG DEVICES
1. DUPLEX RECEPTACLES SHALL BE GROUNDING TYFE, NEMA 5-20R, RATED FOR 20
AMPS, 1 25 VOLTS, WITH PROVISIONS FOR BACK AND SIDE WIRING.
a. SPECIFICATION GRADE DUPLEX RECEPTACLE SHALL BE HUBBELL #5362 SERIES
OR APPROVED EQUAL, HEAVY DUTY, Wi- ITE.
b. ISOLATED GROUND DEDICATED DUPLEX RECEPTACLE SHALL BE HUBBELL
#IG -5362 SERIES OR APPROVED EQUAL, ORANGE.
c. SINGLE RECEPTACLE NEMA LG -20R, 2OA/2P/3W, 25OV, LOCKING DEVICE SHALL
BE HU15E�ELL #2320-A OR APPROVED EQUAL, SINGLE LOCKING, BLACK. MNATE5
WITH HART #G2 1 2 PLUG (@ LENS PROCESS ROOM EQUIPMENT # 1 , 2 * 4.
d. SINGLE RECEPTACLE NEMA 15-20R, 2OA/3P/4W, 25OV, SHALL DE HUBBELL
#8420 OR APPROVED EQUAL, SINGLE. PROVIDE G' CORD AND PLUG AS
REQUIRED. TYPE STD GO (I 2 -AWG) AND 842 1 C PLUG (@ LENS PROCESS
EQUIPMENT #2G).
SINGLE RECEPTACLE NEMA L 15-20R, 2OA/3P/4W, 25OV, SHALL BE HUBBELL OR
APPROVED EQUAL, SINGLE. PROVIDE G' CORD AND PLUG AS REQUIRED. TYPE
STD GO (I 2 -AWG) AND 842 1 C PLUG (@ LENS PROCESS EQUIPMENT #2GB).
2. GROUND FAULT CIRCUIT INTERRUPTER (GPI) DUPLEX RECEPTACLES SHALL BE PROVIDED
WHERE INDICATED.
3. SWITCHES SHALL BE TOGGLE OPERATED, QUIET TYPE, RATED FOR 20 AMPS, 1 20/277
VOLTS, WITH PROVISIONS FOR BACK AND SIDE WIRING. THREE WAY AND FOUR WAY
SWITCHES SHALL BE PROVIDED WHERE INDICATED.
a. SINGLE POLE SWITCHES SHALL BE LEVITON # 1 22 1 SERIES OR APPROVED EQUAL,
SILENT ACTUATING, 20 -AMP, 1 20/277V, WHITE.
b. THREE POLE SWITCHES SHALL BE LEVITON # 1 223 SERIES OR APPROVED EQUAL,
SILENT ACTUATING, 20 -AMP, 1 20/277V, WHITE.
c. ILLUMINATED FRAME SWITCHES SHALL BE LEVITON #57501 SERIES OR APPROVED
EQUAL, SILENT ACTUATING, 15 -AMP, 1 2OV, IVORY.
4. DIMMERS SHALL BE LEVITON SLIDING DIMMER SWITCH, OF A RATING, VOLTAGE AND
WATTAGE SUITABLE FOR LOAD SERVED.
a. CONTRACTOR TO PROVIDE INCANDESCENT OR CFL AS REQUIRED
5. COLORS OF DEVICES AND COVERPLATE5 SHALL WHITE.
6. WIRING DEVICES SHALL BE SPECIFICATION GRADE, AS MANUFACTURED BY HUBBELL,
FA55 * SEYMOUR, ARROW HART, LEVITON AND GENERAL ELECTRIC, LION.
7. COVERPLATES FOR POWER, DATA * TELEPHONE SHALL BE LEVITON OR APPROVED
EQUIP, WHITE, PLASTIC.
8. TIME CLOCK SHALL BE TORK #DG- 100 OR APPROVED EQUAL, 7 -DAY SCHEDULING,
5PDT MAINTAINED CONTACT, 1 20V COIL WITH CABINET.
9. LIGHTING CONTACTORS SHALL BE IN NEMA I ENCLOSURE, NORMALLY OPEN
ELECTRICALLY HELD, 12OV, COIL, 20A. REFER TO PLANS FOR NUMBER OF POLES.
10. DOOR BUZZER (REAR ENTRANCE) SHALL BE EDWARDS #34OA-G5, PUSHBUTTON
SHALL BE EDWARDS #GOO, TRANSFORMER SHALL BE EDWARDS #592 OR APPROVED
EQUALS. MOUNT BUZZER AT 80" AFF. MOUNT TRANSFORMER ABOVE CEILING. MOUNT
PUSHBUTTON AT 48" (FOR WEATHERPROOF BUTTON # 178G -B).
E. LIGHTING AND RECEPTACLE PANELBOARDS
1. BRANCH CIRCUIT PANELBOARD5 SHALL BE DEAD FRONT TYPE, WITH MAIN LUGS OR
MAIN OVERCURRENT DEVICE AS INDICATED, BRANCH OVERCURRENT DEVICES AS
NOTED AND AN EQUIPMENT GROUND BAR, ALL IN A SURFACE OR FLUSH MOUNTED
SHEET STEEL ENCLOSURE. MINIMUM SHORT CIRCUIT CAPACITY SHALL BE 10,000
AMPS SYMMETRICAL FOR 1 20/208V, AND 14,000 AMPS SYMMETRICAL FOR
277/450V APPLICATION UNLESS NOTED OTHERWISE.
2. CIRCUIT BREAKERS SHALL BE BOLT ON TYPE; WITH MOLDED PLASTIC CASE; 1 , 2, OR
3 POLE AS INDICATED; QUICK -MAKE, QUICK -BREAK; AND THERMAL -MAGNETIC TRIP
DEVICE.
3. ALL BREA ERS FEEDING HVAC E UIPMENT SHALL BE HAC RATED UNLESS
K Q R ,
OTHERWISE NOTED.
4. PANELBOARD5 SHALL BE AS MANUFACTURED BY SQUARE D, GENERAL ELECTRIC,
ITE/SIEMENS AND WESTINGHOUSE/CUTLER HAMMER.
F. DISTRIBUTION TRANSFORMERS
1. TRANSFORMERS SHALL BE DRY TYPE, 1 1 5 DEGREE RISE WITH 2 TAPS ABOVE
AND BELOW NORMAL VOLTAGE. TRANSFORMERS SHALL BE AS MANUFACTURED
BY SQUARE D, GENERAL ELECTRIC, ITE/51EMENS, WESTINGHOU5E/CUTLER
HAMMER AND, ACME.
F. DISTRIBUTION TRANSFORMERS
1. TRANSFORMERS SHALL BE DRY TYPE, 1 1 5 DEGREE RISE WITH 2 TAPS ABOVE
AND BELOW NORMAL VOLTAGE. TRANSFORMERS SHALL BE AS MANUFACTURED
BY SQUARE D, GENERAL ELECTRIC, ITE/51EMEN5, WE5TINGHOU5E/CUTLER
HAMMER AND, ACME.
G. SAFETY SWITCHES AND MOTOR STARTERS
1. SAFETY SWITCHES SHALL BE FUSIBLE OR NON -FUSIBLE AS INDICATED ON THE
DRAWINGS. SWITCHES SHALL BE QUICK -MAKE, QUICK -BREAK, HEAVY DUTY
VISIBLE BLADE TYPE. ENCLOSURES SHALL BE NEMA I TYPE UNLESS OTHERWISE
INDICATED ON THE DRAWINGS. FUSED SHALL BE DUAL ELEMENT - TIME DELAY
TYPE.
2. MAGNETIC MOTOR STARTERS SHALL BE COMBINATION TYPE WITH THERMAL
OVERLOAD, INTEGRAL FUSED SAFETY SWITCH, H -O -A SELECTOR SWITCH,
CONTROL TRANSFORMER, RUNNING PILOT LIGHT, NEMA TYPE I ENCLOSURE,
AND (2) NORMALLY OPEN AND (2) NORMALLY CLOSED AUXILIARY CONTACTS.
3. ALL MOTORS OVER 1 /8 HP SHALL BE PROVIDED WITH THERMAL OVERLOAD
PROTECTION. OVERLOAD PROTECTION SHALL BE PROVIDED INTEGRAL WITH
THE MOTOR WINDINGS AND/OR MOTOR CONTROLLER (PROVIDED BY OTHERS)
UNLESS OTHERWISE INDICATED ON DRAWINGS.
H. FIXTURES AND LAMPS
1. ALL FIXTURES SHALL BE SPECIFIED ON THE FIXTURE SCHEDULE.
2. BALLASTS SHALL BE INSTANT START, ELECTRONIC TYPE, CLASS P, "A" SOUND
RATING AND MAXIMUM HARMONIC CONTENT OF I 0%. DIMMING BALLASTS SHALL
BE 3 -WIRE TYPE, WITH DIMMING CAPABILITY TO 10% OF RATED FULL OUTPUT.
3. RECESSED INCANDESCENT FIXTURES SHALL BE PROVIDED THERMAL PROTECTION.
4. FLUORESCENT LAMPS SHALL BE 3500 K. INCANDESCENT LAMPS SHALL BE 130
VOLT. HIGH INTENSITY DISCHARGE LAMPS SHALL BE COATED.
5. EMERGENCY LIGHTING AS INDICATED, SHALL PROVIDE A MINIMUM OF ONE
FOOTCANDLE ALONG THE PATH OF EGRESS. FIXTURE SUPPLIER SHALL PROVIDE
FOOTCANDLE PRINTOUT TO VERIFY EMERGENCY LIGHT LEVELS.
6. ALL FIXTURE / BALLAST / LAMP COMBINATIONS SHALL BE ENERGY SAVING TYPE.
I. FIRE ALARM SYSTEM
1. A COMPLETE FIRE ALARM SYSTEM SHALL BE PROVIDED AS DESCRIBED ON
THE DRAWINGS. ALL DEVICES, WIRING, BACKBOXE5, PROGRAMMING,
START-UP, INSTRUCTION AND TESTING REQUIRED FOR A COMPLETE
OPERATING SYSTEM SHALL BE PROVIDED.
2. THE ELECTRICAL CONTRACTOR SHALL FURNISH SHOP DRAWINGS, COMPLETE
! WITH EQUIPMENT CUTS AND FLOOR PLANS (WITH WIRING INDICATED), AS WELL
AS BATTERY CALCULATIONS, AND VOLTAGE DROP CALCULATIONS FOR REVIEW
AND APPROVAL BY THE ARCHITECT, ENGINEER, AND ALL AUTHORITIES HAVING
JURISDICTION. FLOOR PLAN DRAWINGS SHALL BE STAMPED BY A
PROFESSIONAL ENGINEER RETAINED BY THE CONTRACTOR AND/OR SUPPLIER.
NICET 4 CERTIFICATION AND STAMP IS ACCEPTABLE, IF APPROVED BY THE
AUTHORITY HAVING JURISDICTION.
3. THE ELECTRICAL CONTRACTOR SHALL FURNISH FIRE ALARM DRAWINGS,
CALCULATIONS, AND EQUIPMENT INFORMATION FOR ALL REQUIRED LOCAL
MUNICIPALITY, OR STATE PERMITS. THE ELECTRICAL CONTRACTOR SHALL
ARRANGE AND COORDINATE ALL REQUIRED TESTING AND INSPECTIONS
REQUIRED BY THE LOCAL MUNICIPALITY FIRE DEPARTMENT. THE ELECTRICAL
CONTRACTOR SHALL INCLUDE FIRE DEPARTMENT COSTS IN BID.
4. ALL HVAC UNITS OR GROUP OF HVAC UNITS WITH A COMMON PLENUM AND A
DE51GN CAPACITY GREATER THAN 2000 CFM SHALL BE AUTOMATICALLY SHUT
DOWN ASSOCIATED HVAC UNIT, AND SHALL BE PROVIDED WITH A LOCAL
ANNUNCIATOR/ TEST SWITCH. HVAC DUCT DETECTORS SHALL BE CONNECTED
TO A CENTRAL STATION MONITORING SYSTEM.
5. ALL FIRE ALARM AN DEVICES SHALL BE ADA COMPLIANT WITH A
MINIMUM CANDELA RATING OF 75.
6. FIRE ALARM SYSTEM MONITORING SHALL BE BY OTHERS UNDERSEPARATE
CONTRACT WITH THE TENANT.
7. PROVIDE A SEPARATE LINE ITEM C05T FOR A (1), (3), (5) YEAR MAINTENANCE,
TESTING AND MONITORING AGREEMENT. AGREEMENT TO INCLUDE
MONITORING TO A UL LISTED CENTRAL STATION PER NFPA 72
REQUIREMENTS, ALL CODE REQUIRED TESTING OF THE FIRE ALARM SYSTEM
PER NFPA 72 AND OBC (MONTHLY VISUAL INSPECTION SHALL BE BYTHE
TENANT), CLEANING OF DEVICES SHALL BE DONE UPON SYSTEM REQUEST,
AND ALL COST ASSOCIATED WITH MAINTENANCE OF THE SYSTEM SHALL BE
PROVIDED (DUE TO DEFECTIVE EQUIPMENT ONLY). PROVIDE A YEARLY REPORT
TO THE TENANT.
8. FIRE ALARM SYSTEM SHALL BE BY SIMPLEX, NOTIFIER, PCI, SIEMENS OR
GAMEWELL.
III. PART 3 - EXECUTION
A. GENERAL MISCELLANEOUS
1. ALL CONDUIT RUN IN FINISHED AREAS SHALL BE CONCEALED. CONDUIT
SMALLER THAN 3/4" SHALL NOT BE USED FOR ANY CIRCUIT HOMERUNS.
2. RACEWAYS EXPOSED TO DIFFERENT TEMPERATURES SHALL BE FILLED
WITH AN APPROVED MATERIAL IN ACCORDANCE WITH ARTICLE 300.7
OF THE NATIONAL ELECTRICAL CODE.
3. HANGERS, SUPPORTS, OR FASTENINGS SHALL BE PROVIDED AT EACH
ELBOW, AT THE ENDS OF STRAIGHT RUNS TERMINATING AT BOXES OR
CABINETS, AND AT INTERMEDIATE POINTS AS REQUIRED BY CODE.
CONDUITS OR BOXES SHALL NOT BE SUPPORTED BY CEILING SUPPORT
WIRES OR OTHER CEILING SUPPORTING HARDWARE.
4. FIXTURE SUPPORTS SHALL BE IN ACCORDANCE WITH ARTICLE
4 1 0-1 5 OF THE NATIONAL ELECTRICAL CODE, OR ANY LOCAL CODES
WHICH MY APPLY.
5. PROVIDE PERMANENT NAMEPLATES WITH DESIGNATIONS FOR
PANELBOARDS, FEEDER DEVICES, DISTRIBUTION EQUIPMENT AND
STARTERS.
6. PROVIDE TYPEWRITTEN DIRECTORY CARDS WITH BRANCH CIRCUIT
IDENTIFICATinN FOR BRANCH CIRCUIT PANELBOARD5.
PANELBOARDS, FEEDER DEVICES, DISTRIBUTION EQUIPMENT AND
STARTERS SHALL BE FIELD MARKED TO WARN QUALIFIED PERSONS
OF POTEN F IAL ELECTRIC ARC FLASH HAZARDS IN ACCORDANCE WITH
NEC 110. I G.
7. INSTALL HANDLE GUARDS ON ALL BREAKERS FOR NIGHT LIGHTING,
EMERGENCY AND SIMILAR CIRCUITS.
8. ALL FLUSH MOUNTED PANELBOARD5 SHALL HAVE (3) 3i4"
EMPTY CONDUITS INSTALLED TO ABOVE ACCESSIBLE
CEILING FOR FUTURE USE.
9. THE FINAL LOCATIONS OF ALL EQUIPMENT, OUTLETS, ETC. SHALL BE
SUBJECT TO REASONABLE CHANGES IN LOCATION UP TO THE TIME
OF ROUGHING -IN, AT NO ADDITIONAL COST TO THE TENANT.
10. CONTACT ELECTRIC POWER COMPANY AND MAKE NECESSARY
ARRANGEMENTS FOR ELECTRIC SERVICE.
11. ELECTRICAL CONTRACTOR TO CONTACT TELEPHONE COMPANY AND
MAKE NECESSARY ARRANGEMENTS FOR TELEPHONE SERVICE.
12. AT ALL TIMES KEEP PREMISES AND BUILDING IN A NEAT AND ORDERLY
CONDITION, FOLLOWING TENANT'S INSTRUCTION IN REGARD TO
STORING OF MATERIALS, PROTECTIVE MEASURES AND DISPOSING
OF DEBRIS.
REVIEWED FOR
COQE CQAAPLIANGE
d�P�bVED
APR 0 7 2016
i .
City Of Tutuila
BUILDING DIVISION
r/�c:Y�
Store # C6427
50UTI10ENTER SQUARE
7 100 Southcenter Parkway
Tukwila, WA 98 188
SPACE # 128
Active Revision Number
Revl51on5:
Mark Date By Description
A
Z�
L�
Z�
Arch ltect/
Engineer
F
DESIGN WORLDWIDE
311 EI m Street Suite 600
Cincinnati OH 45202
513 241 3000
wvm.frch.com
FRCH / Architecture, Inc., P.C.
Seal
Thorson : Baker Associates
C O N S U L T I N G E N G I N E E R S
3030 West Streetsboro Road (330) 659-6688 Ph.
Richfield, Ohio 44286 (330) 659-6675 Fax
ARCHITECTURAL SYMBOLS:
O DOOR NUMBER
REVISIONS
ROOM NAME
ROOM NUMBER
X ELEVATION NO. e DETAIL NO.
A-X.X 5HEET NO. A-X.X SHEET NO.
X SECTION NO. X -X. X ELEVATION NO.
A-X.X SHEET NO. SHEET NO.
PROJECT TYPE: ❑ NEW
CORPORATE RELOCATION
❑ FRANCHISE ❑ REMODEL (OPEN)
❑ REMODEL (CLOSED)
I AB TYPE:
❑ FULL LAB ❑ NO LAB
FINISH LAB
51TE TYPE:
U INDOOR LOCATION
OUTDOOR LOCATION
Pearle Standard Version Number:
�.zi, r��i'fEf�
E:C E:
�1 - _IF TUKWILA
Pearle Vision P%Iect No. CG427
`"' ` CENTER
�' °�" ' 032580.000
Architect's Protect No.
Title
SPECIFICATIONS
Date : 03. 18. I G Sheet
Drawn Dy TBA
Checked ey : TBA
Store Number ME P I
CG427 OP
F
M
,
11
R_
m
N
w
Ln
G)
0
Qb
0
N
RKIA
NOTE: ALL SPECS MAY NOT BE USED IN EVERY STORE.
MECHANICAL, ELECTRICAL, * PLUMBING SPECIFICATIONS CD GENERAL NOTE: FOLLOW ALL MANUFACTURERS INSTALLATION AND MAINTENANCE
INSTRUCTIONS.
ROOM NAME
ROOM NUMBER
SUPPLIED/
eX
A-X.X
SHEET NO.
ITEM
MARK
DESCRIPTION
INSTALLED
MFG./PHONE #
MODEL # /
ALTERNATE
REMARKS
BY
COLOR
# I
DIFFUSERS
ALUMINUM CONSTRUCTION W/ BAKED -ON WHITE
MC/Mc
TITUS HVAC (972) 212-4500
TITUS TMS 24X24 OR 12X 12
NONE
ENAMEL FINISH; OPPOSED BLADE DAMPER
WHITE FINISH, LAY -IN
U
RETURN AIR GRILLES
ALUMINUM GRID TYPE W/ BAKED -ON ENAMEL FINISH;
MC/MC
TITUS HVAC (972) 212-4800
TITUS, MODEL 50F 24X24 OR
NONE
1/2" x 1/2" x 112" GRID AND FRAME
24x 12, LAY IN, WHITE FINISH
DUCT
FLEXIBLE ROUND DUCT (MAX 10")
MC/MC
METALFLEX (404) 349-5900
ACOUSTICAL AIRDUCT
OWEN'5 CORNING
ALL DUCTS > I O" TO BE SHEET METAL
>
ACOUSTICAL AIRDUCT V-450-5DI5
(V-450-5DB)
FIBERGLASS 800FR/800FRK
Z
SMOKE DETECTION
SMOKE DETECTORS
MC/Mc
EDWARDS OR APPROVED EQUAL
# I POO I ', # 11-003', OR I P005-
PER LANDLORD
VERIFY WITH LANDLORD FOR SYSTEM REQUIREMENTS
EXHAUST FAN
CEILING -MOUNTED EXHAUST FAN
MC/MC
COOK
AS SPECIFIED ON MECH DRAWINGS
NONE
UNIT HEATERS
EUH- I
CEILING -MOUNTED ELECTRIC UNIT HEATER W/BAKED-ON
MC/Mc
Q -MARK (800)452-4179
AS SPECIFIED ON MECH DRAWINGS
SEE SCHEDULE ON M-1 . 1
ENAMEL FINISH; RECESS MOUNTING ENCLOSURE
WIRING
TELEPHONE
EC / EC
EC TO SELECT
4 PAIR 22/24 AWG
NONE
(PLENUM RATED)
DATA (EYENET-POS)
EC / EC
BERK-TEK
PART # 1003 2 207, CATEGORY 5,
NONE
SEE SHEET E 1.2 / EC TO PROVIDE G' OF EXCESS CABLE AT
4 PAIR UTP (PLENUM RATED)
CASHWRAP AND 3' OF CABLE AT THE PHONE BOARD AND OTHER
LOCATIONS. TENANT VENDOR TO PERFORM PUNCHDOWN AND
j
SYSTEMS VERIFICATION.
ELECTRICAL
EC / EC
GRAYBAR (800) 825-55 17
STO- 12-4GRAY
NONE
SWITCHES
TOGGLE SWITCHES -SINGLE POLE
EC / EC
LEVITON OR APPROVED EQUAL
1 22 1 SERIES SILENT ACTUATING
NONE
20 AMP, 120/ 277 V / WHITE
EC / EC
LEVITON OR APPROVED EQUAL
1 223 SERIES SILENT ACTUATING 20
NONE
TOGGLE SWITCH -THREE WAY
AMP, 120/277 V /WHITE
TOGGLE SWITCH - ILLUMINATED FRAME
EC / EC
LEVITON OR APPROVED EQUAL
57501, SILENT ACTUATING, 15
NONE
AMP, 120V / IVORY
NOVA T SERIES, NT -GOO, GOO
NONE
DIMMER SWITCH - SINGLE POLE
EC / EC
LUTRON OR APPROVED EQUAL
WATTS, INCANDESCENT TYPE/
WHITE SLIDING
DIMMER SWITCH- TWO LOCATION DIMMING
EC / EC
LUTRON OR APPROVED EQUAL
UNIT WITH NTA -2 AUXILIARY UNIT,
NONE
GOO WATTS, INCANDESCENT TYPE /
WHITE SLIDING
RECEPTACLES
DUPLEX RECEPTACLE- 20A, 125V, NEMA 5-2OR
EC / EC
HUBBELL OR APPROVED EQUAL
5362 SERIES, SPECIFICATION
NONE
GRADE, HEAVY DUTY/ WHITE
DUPLEX RECEPTACLE- 20A, 125V, NEMA 5-2OR
HUBBELL OR APPROVED EQUAL
8300 SERIES, HOSPITAL GRADE,
USE ONLY AS DIRECTED BY LOCAL CODES OR REQUIREMENTS
EC / EC
HEAVY DUTY / WHITE
NONE
DUPLEX RECEPTACLE- --A, I I OV, NEMA ---
EC / EC
HUBBELL OR APPROVED EQUAL
NONE
USE FOR ELEC. CONDENSATE DRAIN VALVE ADJACENT TO #2GB
ISOLATED R UND D DUPLEX RECEPTACLE 20A,
EC / EC
HUBBELL OR APPROVED EQUAL
IG -5362 SERIES / ORANGE
NONE
125V, NEMA 5-20R
NONE
NO 5UB5TITUTE5. USE ONLY WHERE REQU. BY CODE, WHERE REQU.
GPI DUPLEX RECEPTACLE 20A, - HOSPITAL GRADE
EC / EC
LEVITON (800) 323-8920
LEVITON '#HG -8898'
BY EQUIP., OR WITHIN SIX (G) FEET OF A WATER SOURCE / WET AREA
U
SINGLE RECEPTACLE -20A, 2P, 3W, 250V, LOCKING
EC / EC
HUBBELL OR APPROVED EQUAL
2320-A, SINGLE LOCKING/
NONE
MATES WITH HART 12 PLUG (@ LENS PROCESS ROOM EQPT
DEVICE, NEMA LG -20R
BLACK
#'5: 1, 2, * 4); MATES WITH HART #G2 12 PLUG
LL
SINGLE RECEPTACLE 20A, 3P, 4W, 250 V, NEMA 15-20R
EC / EC
HUBBELL OR APPROVED EQUAL
8420, SINGLE
NONE
PROVIDE G' CORD AND PLUG AS REQUIRED. TYPE STD GO (I 2 -AWG)
AND 842 1 C PLUG (@ LENS PROCESS ROOM EQPT #2G)
U
SINGLE RECEPTACLE -20A, 3P, 4W, 250V,
EC / EC
HUBBELL OR APPROVED EQUAL
MODEL #/ COLOR
NONE
PROVIDE G' CORD AND PLUG AS REQUIRED. TYPE STD GO (I 2 -AWG)
�J
NEMA LI 5-2OR
AND 842 1 C PLUG (@ LENS PROCESS ROOM EQPT #2GB)
J
Il__I
COVER PLATES
ELECTRICAL / DATA / TELEPHONE COVER PLATES
EC / EC
LEVITON OR APPROVED EQUAL
WHITE / PLASTIC
NONE
FLOOR J BOX
FLOOR BOX WITH COVER
EC / EC
HUBBELL OR APPROVED EQUAL
WITH 52525 BRASS STEEL
NONE
USED AT CONSULTATION TABLES.
COVE GREY
WIRE MOLD
SURFACE METAL RACEWAY
EC / EC
WIREMOLD OR APPROVED EQUAL
G-3000 SERIES / GREY
NONE
USED @ PA55 THKU. LENGTH AS CALLED OUT ON
PLAN. INCLUDE AL ACCESSORIES.
- H N ,
CONTROLS
TIME SWITCH
EC / EC
TORK OR APPROVED EQUAL
5PDT MAINTAINED CONTACT,
NONE
120V COIL WITH CABINET
CR2GOL 5LKIE5 IN NEMA -I
LIGHTING CONTACTOR
EC / EC
GESCO (5 1 3) 32G-2 100
ENCLOSURE, G OR 8 POLE, N. 0.,
NONE
REFER TO ONE LINE DIAGRAM FOR # OF POLES
ELECTRICALLY HELD, 1 20V, COIL,
20A
SIGNALING DEVICES
NOT USED
DOOR BUZZER - REAR ENTRANCE
EC / EC
EDWARDS OR APPROVED EQUAL
BUZZER: 340A -G5, PUSH
NONE
MOUNT BUZZER
R AT 80". MOUNT XFMR ABOVE CEILING. MOUNT PUS
BUTTON AT 48" (FOR WEATHERPROOF PUSH BUTTON: 178G -E3).
DUTTON: GOO, XFMR: 592
DISTRIBUTION
TYPE R I O/ 08V AND 7FE
PANEL BOARDS
EC / EC
GE / GE5CO (5 13) 32G-2 100
AE FOR 277/480V. BREAKERS
9HAl I BE BOLT -ON TYPF.
NONE
SEE PLANS FOR SCHEDULE.
TRANSFORMER
EC / EC
GE / GESCO (5 1 3) 32G-2 100
QL TYPE IN NEMA- I ENCLOSURE
NONE
TRANSFORMER SHALL BE FLOOR MOUNTED ON ISOLATION PADS.
LIGHTING
T / EC
SEE SHEET E 1. 1
TRAFFIC
TRAFFIC SENSOR, REFLECTOR, t COUNTER
T / EC
TRAFFIC COUNTER
TRAFFIC COUNTER CONTRACTOR
NONE
PROVIDED AND INSTALLED BY TR/ FFIC COUNTER CONTRACTOR
COU NTER
CONTRACTOR
MODEL
FOR ALL EXPOSED CONDUIT SHALL BE FIRMLY
CONDUIT SUPPORT
SUPPORTED ON GALVANIZED UNISTRUT OR
SYSTEM
POWER5TRUTOR HANGERS; ON BRACKETS, HANGERS
EC / EC
UNISTRUT (800) 544-1459
AS REQUIRED
POWER5TRUT,
OR PIPE STRAPS; OR BY BEAM CLAMPS.
KINDORF
SINKS
SK4
S.S. SINK FOR BOH -LSU
-T / PC
-KINDRED (800) G2G-577 1
51N : 520 20/ 1 OM I , RAINEK:
1 135, FAUCET: DELTA 10 1 DST
NONE
GC TO MAKE FINAL CONNECTIONS
SK7
30" SINK FOR BOH -5U30
PC / PC
JUST SINKS (847) G78-5 150
LF-ADA- I G 10, STRAINER:
NONE
AUCET: DELTA 583LF-55WF
EPANfUMI5EK
51NK 5K-7 DRAIN
SEMI -CAST BRASS P.O. PLUG, 1 1/4" X 17 GA
PC / PC
DEARBORN BRASS
7 W- I
MCGUIRE
OUTLET
TAILPIECE OFFSET FOR ADA CLEARANCE
TH 5K-7
1 55WC
EYE WASH
EW I
EYEWASH, WALL MOUNTED, AUTOFLOW 90 DEGREE
GC / PC
G 1848
NONE
FOR MOUNTING ON WALL BY MOP SINK UNIT IN LENS PROCESS
SWING -DOWN.
(3 1 2) 733-2G2G
ROOMS. FURNISH. WITH TEMPERING DEVICE 'GUARDIAN' MODEL #
G3 G00.
BI -LEVEL WATER
EWC2
WALL HUNG, BARRIER FREE, ELECTRIC, 120V GOHz I PH,
3 -WIRE GROUND CORD; PLATINUM VINYL FINISH; 8.0
PC/ PC
HALSEY TAYLOR
HAC8FSBL-Q ADA PV
NONE
NOT USED UNLESS FORCED BY LUCODE; MAINTAIN G" MIN. TO WALL
r
COOLER
GPH; SELF- CONTAINED REFRIGERATION CONTROLS,
(G30) 574-3500
ON EA. SIDE FOR VENTILATION MOUNTING HEIGHT PER CODE.
z
PUSH BAR CONTROLS AT FRONT AND SIDE; 3/8" SUPPLY
CONNECTION; 1- 112" OD WASTE CONNECTION
r_�
CD
ELECTRIC HOT WATER
WH I
GLASS LINED WATER HEATER WITH 10 GALLON STORAGE
PC/ PC
A.O.SMITH
DEL- 10
NONE
PLUMBING CONTRACTOR TO COORDINATE WITH ELECTRICAL
HEATER
AND I YEAR WARRANTY. ELEMENT SHALL BE 1 500
(800) 527-1553
CONTRACTOR FOR SPECIFIC VOLTAGE OF UNIT.
WATTS, 208 VAC, SINGLE PHASE, GO HZ. UNIT SHALL BE
PROVIDE MOUNTING SUPPORT SHELF ABOVE MOP SINK WITH
COMPLETELY FACTORY PREWIRED AND SHALL BE UL
HEATER DRAIN PAN. ROUTE T*P RELIEF VALVE PIPING FULLSIZE
__J
LISTED. FURNISH HEATER WITH APPROPRIATE WATTS
AND PROVIDE 3/4' DRAIN PAN DRAIN TO MOP SINK. PROVIDE
n
REGULATOR TEMP AND PRESSURE (T*P) RELIEF VALVE
HEAT TRAPS ON INLET AND OUTLET OF WATER HEATER.
ALONG WITH VACUUM BREAKER VALVE.
DOMESTIC WATER
ET
IN-LINE THERMAL ABSORBER, 0.9 GALLON
PC/ PC
5T-5PROVIDE
HANGING SUPPORT INDEPENDENT OF
EXPANSION TANK
MAXIMUM ACCEPTANCE VOLUME.
WATTS
WATER OR OTHER SERVICE PIPING.
PIPING SUPPORTS
WATER HAMMER ARRESTORS
PC / PC
WATTS/GRAINGER (800) 323-OG20
#3A559
SIOUX PLBG PRODUCTS
REFER TO PLUMBING PLAN FOR LOCATION
FLOOR CLEANOUT5
FCO
REFER TO SHEET P-1 .0 FOR SPECIFICATION
PC / PC
J.R. SMITH (334) 277-8520
4000 SERIES
REFER TO PLUMBING PLAN FOR LOCATION
WALL CLEANOUT5
WCO
REFER TO SHEET P- 1.0 FOR SPECIFICATION
PC/ PC
J.R. SMITH (334) 277-8520
4400 SERIES
REFER TO PLUMBING PLAN FOR LOCATION
REV WED FOR
60QE CC
APPrPLIANCE
'UED
APR 0'7 2016
T
Cify of iu tia
ILDING DMSION
A Subsidiary of the Luxottica Group
4000 Luxottica Place Mason, Ohio 45040
Store # C6427
SOUTIICENTER SQUARE
17100 5outhcenter, Parkway
Tukwila, WA 98 188
SPACE # 128
Active Revision Number
Revisions:
Mark Date By Description
0
Arch Itect/
Engineer
DESIGN WORLDWIDE
fRCH /Architecture, Inc., P.C.
Seal
y Af
-YASf f'>�
36s6i
SJO N ALS
E <rel, 17
Thorson
Thorson -Baker -i- Associates
C O N S U L T I N G E N GI N E E R S
3030 West Streetsboro Road (330) 659-6688 Ph.
Richfield, Ohio 44286 (330) 659-6675 Fax
1111111110
ARCHITECTURAL SYMBOLS:
zn_� REVISIONS
X ELEVATION NO
A X.X SHEEP NO.
ODOOR
NUMBER
ROOM NAME
ROOM NUMBER
DETAIL NO.
eX
A-X.X
SHEET NO.
ELEVATION NO.
X SECTION NO. X -X. X SHEET NO.
A-X.X SHEET NO.
PROJECT TYPE: ❑ NEW
CORPORATE M RELOCATION
❑ FRANCHISE ❑ REMODEL (OPEN)
❑ REMODEL (CLOSED)
LAB TYPE:
❑ FULL LAB ❑ NO LAB
FINISH LAB
SITE TYPE:
❑ INDOOR LOCATION
OUTDOOR LOCATION
Pearle 5tandard Version Number:
V D ECC 1 00
- ,-ry TUKWILA
s
29 2015 Pearle Vision Project No. CG427
Architect's Project No. 032580.000
).-,-RNiia CENTER
Title
SPECIFICATIONS
Date 03. 18.1 G Sheet
Drawn By TBA
Checked By TBA
5tore Number MET-
I .2
CG4271 Of