HomeMy WebLinkAboutPermit PG16-0056 - SALAL CREDIT UNION - ROUGH-IN, BREAKROOM SINK, DISHWASHER AND ELECTRIC WATER HEATERSALAL CREDIT UNION PG16-0056 City of Tukwila • ° Department of Community Development • 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Inspection Request Line: 206-438-9350 Web site: http://www.TukwilaWA.Rov PLUMBING/GAS PIPING PERMIT Parcel No: 0005800037 Permit Number: PG16-0056 Address: 690 STRANDER BLVD 2 Issue Date: 5/18/2016 Permit Expires On: 11/14/2016 Project Name: SALAL CREDIT UNION Owner: Name: BC PARTNERS LLC Address: PO BOX 997 C/O MK PROPERTY National Electrical Code: SERVICES LLC, SNOQUALMIE, WA, International Residential Code Edition: 98065 Contact Person: 2014 Name: TODD STAKSET Address: 1817 112 ST E, TACOMA, WA, 98445 Contractor: 2012 Name: TACOMA PLBG/HTG INC Address: PO BOX 44601, TACOMA, WA, 98448 License No: TACOMPH271PR Lender: r,& Name: Address: Phone: (253) 531-3444 Phone: (253) 531-3444 Expiration Date: 5/12/2018 DESCRIPTION OF WORK: ROUGH -IN AND INSTALL (1) BREAKROOM SINK, (1) DISHWASHER (RESIDENTIAL), (1) 20 GALLON ELECTRIC WATER HEATER Valuation of Work: $4,150.00 Fees Collected: $199.56 Water District: TUKWILA Sewer District: TUKWILA SEWER SERVICE Current Codes adopted by the City of Tukwila: International Building Code Edition: 2012 National Electrical Code: 2014 International Residential Code Edition: 2012 WA Cities Electrical Code: 2014 International Mechanical Code Edition: 2012 WAC 296-46B: 2014 Uniform Plumbing Code Edition: 2012 WA State Energy Code: 2012 International Fuel Gas Code: 2012 r,& 7�r k Permit Center Authorized Signature: Date: I hearby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this development ermit and agree to the conditions attached to this permit. y Signature Date: U Print Name:cn rh 1, This permit shall become null and void if the work is not commenced within 180 days for the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. PERMIT CONDITIONS: 1: ***PLUMBING/GAS PIPING PERMIT CONDITIONS*** 2: No changes shall be made to applicable plans and specifications unless prior approval is obtained from the Tukwila Building Division. 3: All permits, inspection records and applicable plans shall be maintained at the job and available to the plumbing inspector. 4: All plumbing and gas piping systems shall be installed in compliance with the Uniform Plumbing Code and the Fuel Gas Code. 5: No portion of any plumbing system or gas piping shall be concealed until inspected and approved. 6: All plumbing and gas piping systems shall be tested and approved as required by the Plumbing Code and Fuel Gas Code. Tests shall be conducted in the presence of the Plumbing Inspector. It shall be the duty of the holder of the permit to make sure that the work will stand the test prescribed before giving notification that the work is ready for inspection. 7: No water, soil, or waste pipe shall be installed or permitted outside of a building or in an exterior wall unless, adequate provision is made to protect such pipe from freezing. All hot and cold water pipes installed outside the conditioned space shall be insulated to minimum R-3. 8: Plastic and copper piping running through framing members to within one (1) inch of the exposed framing shall be protected by steel nail plates not less than 18 guage. 9: Piping through concrete or masonry walls shall not be subject to any load from building construction. No plumbing piping shall be directly embedded in concrete or masonry. 10: All pipes penetrating floor/ceiling assemblies and fire -resistance rated walls or partitions shall be protected in accordance with the requirements of the building code. 11: Piping in the ground shall be laid on a firm bed for its entire length. Trenches shall be backfilled in thin layers to twelve inches above the top of the piping with clean earth, which shall not contain stones, boulders, cinderfill, frozen earth, or construction debris. 12: The issuance of a permit or approval of plans and specifications shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the Plumbing Code or Fuel Gas Code or any other ordinance of the jurisdiction. 13: The applicant agrees that he or she will hire a licensed plumber to perform the work outlined in this permit. 14: All new plumbing fixtures installed in new construction and all remodeling involving replacement of plumbing fixtures in all residential, hotel, motel, school, industrial, commercial use or other occupancies that use significant quantities of water shall comply with Washington States Water Efficiency ad Conservation Standards in accordance with RCW 19.27.170 and the 2006 Uniform Plumbing Code Section 402 of Washington State Amendments PERMIT INSPECTIONS REQUIRED Permit Inspection Line: (206) 438-9350 8004 GROUNDWORK 1900 PLUMBING FINAL 8005 ROUGH -IN PLUMBING CITY OF TUKWILA Community Development Department • Permit Center • 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 htti)://www.TukwilaWA.gov Plumbing/Gas Permit No. � — $� Project No. Date Application Accepted: Date Application Expires: use PLUMBING / GAS PIPING PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review Applications will not be accepted through the mail or by fax. "Please Print" SITE LOCATION l King Co Assessor's Tax No... 0005800037 Site Address: 690 Strander Blvd Tukwila, WA 98188 Suite Number: Floor: Tenant Name: Salal Credit Union New Tenant: .....Yes ❑ ..No PROPERTY OWNER Name: Salal Credit Union Address: City: State: Zip: CONTACT PERSON — person receiving all project communication Name: Todd Stakset Address: 1817 - 112th Street East City: Tacoma State: WA Zip: 98445 Phone: (253) 531-3444 Fax: (253) 537-0382 Email: todd@tacomaplumbing.com PLUMBING CONTRACTOR INFORMATION Company Name: Tacoma Plumbing & Heating, Inc., Address: 1817 - 112th Street East Suite G City: Tacoma State: WA Zip: 98445 Phone: (253) 531-3444 Fax: (253) 537-0382 Contr Reg No.: TACOWH271PR Exp Date: 05/12/2018 Tukwila Business License No.: Valuation of Project (contractor's bid price): $ 4,150 Scope of Work (please provide detailed information): 1 - Rough in and install (1) Break Room Sink, (1) Dishwasher (residential) 1 - Rough in and install (1) 20 -gallon Electric Water Heater Building Use (per Int'l Building Code): Occupancy (per Int'l Building Code): Utility Purveyor: Water: Sewer: H:\ApplicationsWonns-Applications On Line\2011 Applicatio sTlumbing Permit Application Revised 8.9.1 l.doac Revised: August 2011 bh Pagel of 2 Indicate type of plumbing fixtures and/or gas piping outlets being installed and the quantity below: Fixture Type Qty Bathtub or combination bath/shower Dishwasher, domestic with 1 independent drain Shower, single head trap Sinks 1 Rain water system — per 2 drain (inside building) Grease interceptor for commercial kitchen (>750 gallon capacity) Each additional medical gas inlets/outlets greater than 5 Atmospheric -type vacuum breakers not included in lawn sprinkler backflow protections 1-5 Fixture Type Qty Bidet Drinking fountain or water cooler(per head Lavato Urinal Water heater and/or vent 1 Repair or alteration of 2 water piping and/or water treatment equipment Backflow protective device other than atmospheric - type vacuum breakers 2 inch (51 mm) diameter or smaller Atmospheric -type vacuum breakers not included in lawn sprinkler backflow lection over 5 PERMIT APPLICATION NOTES - Fixture Type Qty Clothes washer, domestic Food -waste grinder, commercial Wash fountain Water closet Industrial waste treatment interceptor, including trap and vent, except for kitchen type grease interceptors Repair or alteration of drainage or vent piping Backflow protective device other than atmospheric -type vacuum breakers over 2 inch (51 mm) diameter Gas piping outlets Fixture Type Qty Dental unit, cuspidor Floor drain Receptor, indirect waste Building sewer and each trailer pink sewer Each grease trap (connected to not more than 4 fixtures - <750 gallon capacity Medical gas piping system serving 1-5 inlets/outlets for a specific as Each lawn sprinkler system on any one meter including backflow protection devices Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The Building Official may grant one extension of time for an additional period not to exceed 180 days. The extension shall be requested in writing and justifiable cause demonstrated. Section 103.4.3 International Plumbing Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER OR Date: Print Name: Todd Stakset Day Telephone: (253) 531-3444 Mailing Address: todd@tacomaplumbing.com Tacoma WA 98335 city state zip H:\Applications\Form Applications On Line\201 I Applications\Plumbing Permit Application Revised 8-9-11.docx Revised: August 2011 Page 2 of 2 bh DESCRIPTIONS ' AID PermitTRAK $199.56 PG16-0056 Address: 690 STRANDER BLVD 2 Apn: 0005800037 $199.56 PLUMBING $191.88 PERMIT ISSUANCE BASE FEE R000.322.100.00.00 0.00 $32.50 PERMIT FEE R000.322.100.00.00 0.00 $121.00 PLAN CHECK FEE R000.322.103.00.00 0.00 $38.38 TECHNOLOGY FEE $7.68 TECHNOLOGY FEE TOTAL FEES PAID BY RECEIPT: R8362 R000.322.900.04.00 0.00 $7.68 $199.56 Date Paid: Tuesday, May 03, 2016 Paid By: LISA HANSELAR Pay Method: CREDIT CARD 07154D Printed: Tuesday, May 03, 2016 2:39 PM 1 of 1 EmAr SYSTEMS INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. !"0 CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Pro'ect: 0,&D /T U"J/V?J Typgof Inspection: -rWrM IR 1A)6 r/�% It - Address: Address: 90 STrrlvllse-�e Date Called: Special Instructions: Z Date Wanted: �V a. Gr Requester: Phone No: NApproved per applicable codes. t__J Corrections required prior to approval. REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. �' INSPECTION RECORD ` Retain a copy with permit P6 " 00, I SPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Proje t: C►- r Type of Inspection: a �(u N�K1 Addrq�s: sf �d Datec�c" Z Special Instructions: 11A1 Date Hied: a.m. 5-' p.m. Re e�ter: / I- A. f fie Phone No: -77--T- 7 — 9U21 q IInspector: ,/i / IDate:4`— ZS— fj!:� REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd„ Suite 100. Call to schedule reinspection. ( fn INSPECTION RECORD Retain a copy with permit SPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd.., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 ProiecType ( ��- of Insp ction: / �( Address: V Date Calle Special Instructions: 4M Date Wanted:// a.m. s ),0— (4 p.m. Requa�ster: Phone o: 3 -1)-2,- 7-o Inspector: Date: s REINSPECTION FEE REQUIRED. Prior to next inspection, tee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule. reinspection. PERMIT CARD COPY PLAN REVIEW/ROUTING SLIP PERMIT NUMBER: PG16-0056 DATE: 05/03/16 PROJECT NAME: SALAL CREDIT UNION SITE ADDRESS: 690 STRANDER BLVD X Original Plan Submittal Response to Correction Letter # DEPARTMENTS: A -s �wG E-0w1P Building Division 0 Public Works PRELIMINARY REVIEW: Not Applicable ❑ (no approval/review required) REVIEWER'S INITIALS: APPROVALS OR CORRECTIONS: Approved ❑ Corrections Required ❑ (corrections entered in Reviews) Notation: REVIEWER'S INITIALS: Revision # before Permit Issued Revision # after Permit Issued Fire :Prevention ❑ Planning Division ❑ Structural ❑ Permit Coordinator DATE: 05/05/16 Structural Review Required ❑ DATE: DUE DATE: Approved with Conditions Denied ❑ (ie: Zoning Issues) DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: 06/02/16 12/18/2013 TACOMA PLBG/HTG INC Home Inspafiol Contact. Safety & Health Washington State Department of Labor & industries TACOMA PLBG/HTG INC Page 1 of 2 Search L&I —wR4rX A -'L Index Help Nly L,CI Claims & Insurance Workplace Rights Trades & Licensing Owner or tradesperson PO BOX 44601 STAKSET, TODD ALLEN TACOMA, WA 98448 License no. 253-531-3444 Principals PIERCE County STAKSET, TODD ALLEN, PRESIDENT 04/24/2016 STAKSET, ALLEN IVAN, VICE PRESIDENT Expiration date STAKSET, BONNIE DEANNE, TREASURER 04/24/2018 STAKSET, ALLEN I, PRESIDENT $12,000.00 (End: 04/26/2012) STAKSET, TODD A, VICE PRESIDENT (End: 04/26/2012) Effective date WA UBI No. Business type 600 028 303 Corporation License Verify the contractor's active registration / license / certification (depending on trade) and any past violations. Construction Contractor Active. .......................................................... Meets current requirements. License specialties $1,000,000.00 GENERAL License no. TACOMPH271PR Effective date Effective — expiration 04/24/2016 10/1911973— 05/12/2018 Expiration date Bond 04/24/2018 Great American Ins Co $12,000.00 Bond account no. 1698010 Received by L&I Effective date 08/30/2011 08/27/2011 Expiration date Until Canceled Bond history Insurance Federated Mutual Ins Co $1,000,000.00 Policy no. 9381870 Received by L&I Effective date 04/25/2016 04/24/2016 Expiration date 04/24/2018 https://secure.Ini.wa.gov/verify/Detail.aspx?UBI=600028303&LIC=TACOMPH271PR&SAW= 5/18/2016 MECHANICAL ABBREVIATIONS ABBREV. DESCRIPTION AFF ABOVE FINISHED FLOOR BLDG BUILDING CO CLEANOUT CFH CUBIC FEET PER HOUR CW COLD WATER CV : CHECK VALVE DEG F. `F DEGREE FAHRENHEIT DN DOWN EQUIP EQUIPMENT ELEC, EC ELECTRICAL, ELECTRICAL CONTRACTOR ELEV ELEVATION FIL FLOOR FCO FLOOR CLEANOUT OFCI OWNER FURNISHED CONTRACTOR INSTALLED FT FEET GC GENERAL CONTRACTOR HVAC HEATING, VENTILATION, & AIR CONDITIONING HW HOT WATER I(W INVERT ELEVATION _ —=a KILOTT LB POUND MC MECHANICAL HVAC CONTRACTOR 1/2" MAXIMU NX MIN MINIMUM NTS NOT TO SCALE NO., � NUMBER PC PLUMBING CONTRACTOR POC POINT OF CONNECTION P.D.I. PLUMBING AND DRAINAGE INSTITUTE . PRESS. PRESSURE PRV PRESSURE REDUCING VALVE REQ'D REQUIRED SCO SURFACE CLEANOUT SS SANITARY SEWER TEMP TEMPERATURE TYP TYPICAL . VTR , VENT THROUGH ROOF W VOLTS,VOLTAGE PLUMBING FIXTURE SCHEDULE SYMBOL DESCRIPTION W. V CIN HW REMARKS P-1 WATER CLOSET ` TANK TYPE 2" 1Y2- 1/2" 1/2- INSTALL NO SEEP WAX SEAL, MOUNTING HARDWARE do CAPS, OPEN FRONT SEAT, SUPPLY WASTE PIPING CHECK VALVE PIPING INSULATION SHALL — - — - - -- VENT PIPING STOP. SEAT MOUNTING HEIGHT TO MEET WASHINGTON ADA REQUIREMENTS. BALL VALVE FLOOR MOUNT VENT THROUGH ROOF REUEF OR SAFETY VALVE .e ;-, I F ,.. , . of alpprLm".;C, a .yeti �'oI�'� �ir1a� f;CD�I�IIIf�Frea i- Fia�l� t �, r < nowla djE)d: WATER CLOSET TO BE INSTALLED AT EXISTING WATER CLOSET ROUGH -IN. P-2 LAVATORY WALL MOUNT 2" 1Y2- 1/2" Y2" INSTALL LEVER HANDLED FAUCET, FLAT GRID DRAIN, P -TRAP, & SUPPLY STOPS. RIM MOUNTING PIPE SADDLE TYP. a ( ) Date: _ —=a HEIGHT TO MEET WASHINGTON ADA REQUIREMENTS. P-3 SINK COUNTER MOUNT 2" 1Y2- 1/2" 1/2• INSTALL LEVER HANDLED FAUCET, FLAT GRID DRAIN, P -TRAP, & SUPPLY STOPS. MOUNTING PER City of Tukwila PIPING INSULATION SHALL RUN CONTINUOUS THRU--- PIPE CLAMP (TYP.) BUILDING DIVISION - HEIGHT ARCHITECTURAL DRAWINGS. STAINLESS STEEL PIPE CLAMP. ---a PLUMBING EQUIPMENT SCHEDULE SYMBOL DESCRIPTION EWH-1 ELECTRIC WATER HE&TTR - 20 GALLON, 120 VOLT/1 PHASE, SET LEAVING WATER TEMPERATURE AT 147, COMPLETE WITH FACTORY INSTALLED y4- RELIEF AND AN OPERATING WEIGHT OF 280 POUNDS. ExT-1 EXPANSION TANK - AMTROL THERM-X-TROL MODEL ST -5, 2.1 GALLON VOLUME, MAXIMUM ACCEPTANCE VOLUME OF 0.9 GALLONS, BLADDER TYPE, FACTORY PRECHARGED AT 40 PSIG. OPERATING WEIGHT OF 40 LBS. _ TMV-1 THERMOSTATIC MIXING VALVE - WATTS MODEL jLFMMV-UT-M1 (10 SET OUTLET TEMPERATURE AT 129F. PLUMBING LEGEND SYMBOL. DESCRIPTION SYMBOL DESCRIPTION CMU WALL COLO WATER PIPING O FCO/ SCO FLOOR CLEANOUT (FCO) ` SURFACE CLEANOUT (SCO) - — - - - - — HOT WATER PIPING (12(Y) --SII --- UNION (TYPICAL OF 3) WASTE PIPING CHECK VALVE PIPING INSULATION SHALL — - — - - -- VENT PIPING —v� BALL VALVE OVTR VENT THROUGH ROOF REUEF OR SAFETY VALVE .e ;-, I F ,.. , . of alpprLm".;C, a .yeti �'oI�'� �ir1a� f;CD�I�IIIf�Frea i- Fia�l� t �, r < nowla djE)d: CW HW WATER HAMMER ARRESTOR, LETTER INDICATES SIZE PLUMBING GENERAL � NOTES 1. PIPING MATERIAL SCHEDULE: PIPING : LOCATION MATERIAL JOINT COLD WATER (- _MAINS): ALL COPPER LEAD FREE SOLDER HOT WATER (MAINS): ALL COPPER LEAD FREE SOLDER COLD WATER (BRANCH): ALL PIX MECHANICAL HOT WATER (BRANCH):. ALL PIX MECHANICAL WASTE: ALL ABS SOLVENT CEMENT INDIRECT. WASTE: ALL CPVC SOLVENT CEMENT VENT: ALL ABS SOLVENT CEMENT TACOMA PLUMBING 2. PIPING INSULATION SCHEDULE: ' ' and HEATING, Inc. PIPING PIPE INSULATION INSULATION MINIMUM CONDUCTIVITY COMMERCIAL TYPE SIZE TYPE WALL THICKNESS RANGE e HORIZONTAL COLD WATER (COPPER): ALL POLYFOAM 112". INDUSTRIAL HOT. WATER: < 1Y2" POLYFOAM 1 PER WSEC 0.21-0.28 A) ALL PIPING INSULATION & COVERINGSSHALL` HAVE AN ASTM FLAME SPREAD RATING OF 25 OR UTILITIES LESS & AN ASTM SMOKE DEVELOPED RATING OF 50 OR LESS. 1817 -112th Street East . 3. MATER1 METHODS & INSTALLATION SHALL COMPLY WITH THE PROVISIONS OF THE 2012 EDITION UNIFORM PLUMBING CODE Suite G Tacoma ` Washington 4. PLUMBING PLANS ARE SCHEMATIC & DO NOT SHOW EVERY OFFSET REQUIRED PRIOR TO COMMENCING 9 ROUGH -IN, COORDINATE WITH ALL TRADES FOR ROUTING & CLEARANCE REQUIREMENTS. 98445 5. PRIOR TO ROUGH -IN FOR ALL PLUMBING FIXTURES & .OWNER PROVIDED APPLIANCES, VERIFY MOUNTING P.O.BOX 44601, HEIGHT ELEVATIONS & ROUGH -IN LOCATIONS WITH THE ARCHITECTURAL FLOOR PLANS, ARCHITECTURAL INTERIOR ELEVATIONS, do THE.GENERAL CONTRACTOR. Tacoma,Washington 6.. I SLOPE ALL WASTE PIPING 3 & SMALLER AT 1 4 P 98444 " / PER LINEAL FOOT, &SLOPE ALL WASTE PIPING 4 & LARGER AT 1/8" PER LINEAL FOOL (253) 531-3444 7. WHERE POSSIBLE INSTALL SUSPENDED PIPING WITHIN 12" OF BUILDING STRUCTURE. FAX (253) 537-0382 8. PIPING PENETRATIONS OF FIRE RATED WALLS OR FLOORS SHALL BE SLEEVED & FIRE STOPPED WITH WWW.TACOMAPWMBING.COM UL LISTED MATERIALS SO AS TO MAINTAIN. THE INTEGRITY & RATING OF THE WALLS OR FLOORS:. 9. PROVIDE DIELECTRIC CONNECTIONS BETWEEN DISSIMILAR .METALS.` . 10. INSTALL CLEANOUTS SO THEY ARE EASILY ACCESSIBLE. SALAL CREDIT UNION 11. PLUMBING EQUIPMENT VALVES SHALL BE LOCATED IN EASILY ACCESSIBLE LOCATIONS, UNLESS SHOWN ON BRANCH REMODEL ARCHITECTURAL DRAWINGS. REQUIRED ACCESS ` PANELS SHALL BE PROVIDE BY & INSTALLED BY THE GENERAL CONTRACTOR. 12. PROVIDE FOOTING SLEEVE WHERE NECESSARY. 13. TRENCHING, BACKFILLING & COMPACTING FOR UNDERGROUND PLUMBING PIPING :SHALL BE THE RESPONSIBILITY OF GENERAL CONTRACTOR UNLESS STATED OTHERWISE .IN THE CONTRACT DOCUMENTS. 14. PROVIDE FULL PORT BALL VALVES. 15. CONDENSATE PUMPS & PIPING PROVIDED & INSTALLED BY OTHERS. 16. GAS PIPING, VALVES, REGULATORS, EQUIPMENT CONNECTIONS,' & METER PROVIDED & INSTALLED BY OTHERS. 17. PAINTING OF PIPING & PIPING COMPONENTS BY OTHERS. PROPERTY INFORMATION T NUM CEL 5ls0000250 PLUMBING DRAWINGS SHEET INDEX SHEET NUMBER DESCRIPTION PO.01 PLUMBING LEGEND, SCHEDULES, DETAILS, & PARTIAL SITE PLAN PLUMBING P1.01 PLUMBING PLANS EXTEND & SECURE TO BUILDING STRUCTURE (TYP.) PRE -CHARGE TANK TO & PRESSURE RELIEF VALVE.: EQUAL LINE PRESSURE, - INSULATION CONTINUOUS SECURE TO BUILDING. ROUTE RELIEF PIPE THRU EXTERIOR THROUGH PIPE CLAMP WALL,. TERMINATE 6" ABOVE FINISHED (TYPICAL) EXT 1 GRADE WITH 90' DOWNTURNED ELBOW. UNISTRUT T_1 CW H UNISTRUT =______ �'-- INSTALL MR)LPOWER PROVIDED &INSTALLED - PIPE SADDLE i (TYPICAL). , UNION (TYP) BY THE ELECTRICAL CONTRACTOR. H EFEE--E SEISMIC BRACE DIDG f`I AUD _----- REVIEWED FOR CODE COMPLIANCE . APPROVED MAY 17 ME rj 'i City of Tukwila SLJILCiI�i blVllt�i�J PLUMBING LEGEND, SCHEDULES, NOTES, & DETAILS THE IDEAS AND DESIGNS INCORPORATED HERON, AS AN INSTRUMENT OF PROFESSIONAL SERVICE, IS THE PROPERTY OF TACOMA PLUMING & HEATING„ INC. AND IS NOT M BE USED, IN WHOLE, PART, OR FOR BIDDING PURPOSES WITHOUT FIRST GAINING. WRITTEN CONSENT OF TACOMA PLUMING & HEATING TIO. DESIGNED: B.COLE DRAWN: B.COLE REVIEWED: K.GILBERTSON DATE: 04-29-2016 JOB NUMBER: 16016 REVISION: PERMIT REVIEW SET 04-29-2016 RLE COPY CMU WALL CMU WALL _ . rmit Now Y" X 1" NAIL -IN PICAL OF 4) Y" X 1" NAIL -IN is (T (TYPICAL OF 3) yv W(ppr vp.I uViect to errors and o��l� �ac��ls. PIPE CLAMP (TYP.) PIPING INSULATION SHALL _:ro vc ..jair y% ...: r .. ;,t. e,i c , , , TI..�c;.:(�,a i�S IIPiIFirlt Clf�t`��3 ?� IFeda`?JZ7( SUPERSTRUT RUN CONTINUOUS THRU }' �: �,er..;� ,y ltl.�Il,<3i,E:tt. ve 2t)if f i�i3L�G���iIII�IY2@.efsl3t PIPE CLAMP. ===a .e ;-, I F ,.. , . of alpprLm".;C, a .yeti �'oI�'� �ir1a� f;CD�I�IIIf�Frea i- Fia�l� t �, r < nowla djE)d: CW HW HW PIPE SADDLE TYP. a ( ) Date: _ —=a CW PIPE SADDLE (TYP.) City of Tukwila PIPING INSULATION SHALL RUN CONTINUOUS THRU--- PIPE CLAMP (TYP.) BUILDING DIVISION - UNISTRUT PIPE CLAMP. ---a CORE DRILL AT STRUT PLATE HOLE CENTERLINE � 8" ALL THREAD ROD,_ EXPANSION TANK PER THERMOSTATIC MIXING. VALVE EQUIPMENT SCHEDULE FACTORY INSTALL TEMPERATURE EXTEND & SECURE TO BUILDING STRUCTURE (TYP.) PRE -CHARGE TANK TO & PRESSURE RELIEF VALVE.: EQUAL LINE PRESSURE, - INSULATION CONTINUOUS SECURE TO BUILDING. ROUTE RELIEF PIPE THRU EXTERIOR THROUGH PIPE CLAMP WALL,. TERMINATE 6" ABOVE FINISHED (TYPICAL) EXT 1 GRADE WITH 90' DOWNTURNED ELBOW. UNISTRUT T_1 CW H UNISTRUT =______ �'-- INSTALL MR)LPOWER PROVIDED &INSTALLED - PIPE SADDLE i (TYPICAL). , UNION (TYP) BY THE ELECTRICAL CONTRACTOR. H EFEE--E SEISMIC BRACE DIDG f`I AUD _----- REVIEWED FOR CODE COMPLIANCE . APPROVED MAY 17 ME rj 'i City of Tukwila SLJILCiI�i blVllt�i�J PLUMBING LEGEND, SCHEDULES, NOTES, & DETAILS THE IDEAS AND DESIGNS INCORPORATED HERON, AS AN INSTRUMENT OF PROFESSIONAL SERVICE, IS THE PROPERTY OF TACOMA PLUMING & HEATING„ INC. AND IS NOT M BE USED, IN WHOLE, PART, OR FOR BIDDING PURPOSES WITHOUT FIRST GAINING. WRITTEN CONSENT OF TACOMA PLUMING & HEATING TIO. DESIGNED: B.COLE DRAWN: B.COLE REVIEWED: K.GILBERTSON DATE: 04-29-2016 JOB NUMBER: 16016 REVISION: PERMIT REVIEW SET 04-29-2016 i Tacoma, Washington 98445 P.O. Box 4460.1 Tacoma, Washington 98444 (253) 5.31-3444 FAX (253) 537-0382 WWW.TACOMAPWMBING.COM WON NWOM "OUT "w WMIN i ARITiEN� CONSENT OF TAMM PLUIBM & WAMID NQ RECEIVED CITY OF TUKVVILA MAY 0.3 2016 DESIGNED: DRAWN: REVIEWED: DATE: B.COLE B.COLE K.GILBERTSON 04-29-2016 JOB NUMBER: 16016 REVISION: PERMIT REVIEW SET 04-29-2016