Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Permit PG16-0090 - CONAM MANAGEMENT - BREAKROOM SINK, WATER HEATER AND DISHWASHER
CONAM MANAGEMNET 16000 CHRISTENSEN RD SUITE 250 PG16-0090 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Inspection Request Line: 206-438-9350 Web site: http://www.TukwilaWA.eov PLUMBING/GAS PIPING PERMIT Parcel No: 2523049077 Permit Number: PG16-0090 Address: 16000 CHRISTENSEN RD 250 Issue Date: 6/29/2016 Permit Expires On: 12/26/2016 Project Name: CONAM MANAGEMENT Owner: Name: BRCP RIVERVIEW PLAZA LLC Address: 248 HOMER AVE, PALO ALTO, WA, 94301 Contact Person: 2012 Name: BRIAN KNAPIK Address: 8040161ST AVE NE #351, REDMOND, WA Cities Electrical Code: WA, Contractor: 2012 Name: MOSS BAY PLUMBING LIMITED Address: 8040161 AVE VE, REDMOND, WA, WA State Energy Code: 98052 License No: MOSSBPL00000 Lender: Name: Address: Date: G DESCRIPTION OF WORK: Phone: (206) 650-6365 Phone: (425) 868-8446 Expiration Date: 3/15/2017 INSTALL NEW BREAKROOM SINK, WATER HEATER AND DISHWASHER TO EXISTING PLUMBING Valuation of Work: $1,400.00 Fees Collected: $131.78 Water District: TUKWILA Sewer District: TUKWILA Current Codes adopted by the City of Tukwila: International Building Code Edition: 2012 National Electrical Code: 2014 International Residential Code Edition: 2012 WA Cities Electrical Code: 2014 International Mechanical Code Edition: 2012 WAC 296-4613: 2014 Uniform Plumbing Code Edition: 2012 WA State Energy Code: 2012 International Fuel Gas Code: 2012 Permit Center Authorized Signature: Date: G I hearby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this development permit and agree to the conditions attached to this permit. Signature: Date: Print Name: This permit shall become null and void if the work is not commenced within 180 days for the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. PERMIT CONDITIONS: 1: ***PLUMBING/GAS PIPING PERMIT CONDITIONS*** 2: No changes shall be made to applicable plans and specifications unless prior approval is obtained from the Tukwila Building Division. 3: All permits, inspection records and applicable plans shall be maintained at the job and available to the plumbing inspector. 4: All plumbing and gas piping systems shall be installed in compliance with the Uniform Plumbing Code and the Fuel Gas Code. 5: No portion of any plumbing system or gas piping shall be concealed until inspected and approved. 6: All plumbing and gas piping systems shall be tested and approved as required by the Plumbing Code and Fuel Gas Code. Tests shall be conducted in the presence of the Plumbing Inspector. It shall be the duty of the holder of the permit to make sure that the work will stand the test prescribed before giving notification that the work is ready for inspection. 7: No water, soil, or waste pipe shall be installed or permitted outside of a building or in an exterior wall unless, adequate provision is made to protect such pipe from freezing. All hot and cold water pipes installed outside the conditioned space shall be insulated to minimum R-3. 8: Plastic and copper piping running through framing members to within one (1) inch of the exposed framing shall be protected by steel nail plates not less than 18 guage. 9: Piping through concrete or masonry walls shall not be subject to any load from building construction. No plumbing piping shall be directly embedded in concrete or masonry. 10: All pipes penetrating floor/ceiling assemblies and fire -resistance rated walls or partitions shall be protected in accordance with the requirements of the building code. 11: Piping in the ground shall be laid on a firm bed for its entire length. Trenches shall be backfilled in thin layers to twelve inches above the top of the piping with clean earth, which shall not contain stones, boulders, cinderfill, frozen earth, or construction debris. 12: The issuance of a permit or approval of plans and specifications shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the Plumbing Code or Fuel Gas Code or any other ordinance of the jurisdiction. 13: The applicant agrees that he or she will hire a licensed plumber to perform the work outlined in this permit. 14: All new plumbing fixtures installed in new construction and all remodeling involving replacement of plumbing fixtures in all residential, hotel, motel, school, industrial, commercial use or other occupancies that use significant quantities of water shall comply with Washington States Water Efficiency ad Conservation Standards in accordance with RCW 19.27.170 and the 2006 Uniform Plumbing Code Section 402 of Washington State Amendments PERMIT INSPECTIONS REQUIRED Permit Inspection Line: (206) 438-9350 1900 PLUMBING FINAL 8005 ROUGH -IN PLUMBING CITY OF TUKW1. Community Development Department Permit Center • 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 littp://www.Tuk\vi]aWA.00v PLUMBING / GAS PIPING PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. "Please Print" p,r/v s 6 q� King Co Assessor's Tax No.: Z � Zf/-5 ® l © /- /li Site Address: �f� �/ /s ) /�� Suite Number: Z �� Floor: �Z— Tenant Name: IV OtfV A,7 l New Tenant: ] ....Yes No kZ Name: /13 /Z CP X /,)i c,,A I/l % AZ Address: m, 1/l r 7 ,' aJ IP 1n t_ City: State: (,r✓� Zip: / J CONTAC,I PERSON .Y -person receiving all project corriinumcation n, Name: Address: City: State: Zip: Phone Email: PLUMBING CONTRACTOR INFORMATION Company Name: Z Address: IiW City:ATA State Zip: b, Phone:�_ 12 Contr Reg .-S S C> _gl a V o®Fxp Date:zz �� J Tukwila Business License No.: i Valuation of Project (contractor's bid price): $ b �� U Scope of Work tplease provide detailed information): t Building Use (per Int'l Building Code): Occupancy (per Int'l Building Code): Utility Purveyor: Water: Sewer: H:Wpplications\Forms-Applications On Line\2011 Application0lumbing Permit Application Revised 5-9-1 I.docx Revised: August 2011 Page 1 of 2 bh indicate type of plumbing fixtures and/c. _ .s piping outlets being installed and the quantl zlow: Fixture Type Qty Bathtub or combination bath/shower Dishwasher, domestic with 1 independent drain l Shower, single head trap Sinks Rain water system — per r drain (inside building) Grease interceptor for commercial kitchen (>750 gallon capacity) Each additional medical gas inlets/outlets greater than 5 Atmospheric -type vacuum breakers not included in lawn sprinkler backflow protections (1-5) Fixture Type Qty Bidet Drinking fountain or water cooler (per head) Lavatory Urinal Water heater and/or vent Industrial waste r Repair or alteration of water piping and/or water treatment equipment Backflow protective device other than atmospheric - type vacuum breakers 2 inch (51 mm) diameter or smaller Atmospheric -type vacuum breakers not included in lawn sprinkler backflow protection s over 5 PERMIT APPLICATION NOTES - Fixture Type Qty Clothes washer, domestic Food -waste grinder, commercial Wash fountain Water closet Industrial waste treatment interceptor, including trap and vent, except for kitchen type grease interceptors Repair or alteration of drainage or vent piping Backflow protective device other than atmospheric -type vacuum breakers over 2 inch (51 mm) diameter Gas piping outlets Fixture Type Qty Dental unit, cuspidor Floor drain Receptor, indirect waste Building sewer and each trailer park sewer Each grease trap (connected to not more than 4 fixtures - <750 gallon capacity Medical gas piping system serving 1-5 inlets/outlets for a specific gas Each lawn sprinkler system on any one meter including backflow protection devices Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The Building Official may grant one extension of time for an additional period not to exceed 180 days. The extension shall be requested in writing and justifiable cause demonstrated. Section 103.4.3 International Plumbing Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDIN( Signature: Date: Print Name: Mailing A& H:Wpplications\Forms-Applications On Line\2011 Applications\Plumbing Permit Application Revised 8-9-11.docx Revised: August 2011 Page 2 of 2 bh DESCRIPTIONS PermitTRAK 1 $131.78 PG16-0090 Address: 16000 CHRISTENSEN RD 250 Apn: 2523049077 $131.78 PLUMBING $125.50 PERMIT ISSUANCE BASE FEE R000.322.100.00.00 0.00 $32.50 PERMIT FEE R000.322.100.00.00 0.00 $93.00 TECHNOLOGY FEE $6.28 TECHNOLOGY FEE TOTAL FEES PAID BY RECEIPT: R8857 R000.322.900.04.00 0.00 $6.28 $131.78. - Date Paid: Wednesday, June 29, 2016 Paid By: MOSS BAY PLUMBING LIMITED Pay Method: CHECK 15636 Printed: Wednesday, June 29, 2016 11:33 AM 1 of 1 .r1! 1 SYSTEMS INSPECTION RECORD U2-- Retain a copy with permit �� j6' 00 INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Pr/o'''eect: w �0 01 "1 Type f Inspection: r ( i' f Address:Date I & ado .. cto-ttik Called: -Z-yo Special Instructions: n� Da eW to / a.m. — (� p.m. Reuestgr: Ir���� Phone No: -.6-rc -ro36, Inspector. Date:_ 7 S—/ %% -- REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. INSPECTION RECORD Retain a copy with permit I�6f6�00 0 INVECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Project: Pox Type gprs ectio�: o r( c� ddress: Dat Called: 2-5 Special Instructions: Dat Wanted: a.m. p.m. Re uestgr: �S s Phon1-06 e No; 6Sa 36}" RApproved per applicable codes. 4 Corrections required prior to approval. COMMENTS: ac N Inspector: Date: If REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Cali to schedule reinspection. MOSS BAY PLUMBING LIMITED inWashington State Department of Labor & Industries Page 1 of 2 Mome Espanol Contact Search L&I A -L Index Help My L&I Safety & Health Claims & Insurance Workplace Rights Trades & Licensing MOSS BAY PLUMBING LIMITED Owner or tradesperson Principals KNAPIK, BRIAN JOHN, PRESIDENT KNAPIK, MAXINE BIELBY, SECRETARY KNAPIK, ANDREW BRIAN, VICE PRESIDENT (End: 03/08/2013) Doing business as MOSS BAY PLUMBING LIMITED 8040.161 ST AVE NE PMB 351 REDMOND, WA 98052-3834 425-868-8446 KING County WA UBI No. Business type 602 049 480 Corporation Governing persons ANDREW B KNAPIK BRIAN JOHN KNAPIK; MAXINE B KNAPIK; License Verify the contractor's active registration / license / certification (depending on trade) and any past violations. Construction Contractor. Active. Meets current requirements. License specialties PLUMBING License no. MOSSBPL00000 Effective — expiration 09/20/2000— 03/15/2017 Bond ................ American Contractors Indem CO $6,000.00 Bond account no. 100136636 Received by L&I Effective date 08/23/2010 08/24/2010 Expiration date Until Canceled Bond history Insurance ..................... _....... Western National Assur Co $1,000,000.00 Policy no. CPP106741700 Q Received by L&I Effective date V J — V /�(q W- 3 11/16/2015 12/15/2013 httpsJ/secure.Ini.wa.gov/verify/Detail.aspx?UBI=602049480&LIC=MOSSBPLOOOOO&SAW= 6/29/2016