Loading...
HomeMy WebLinkAboutPermit PG16-0092 - MCKAY RESIDENCE - ELECTRIC WATER HEATERThis record contains information which is exempt from public disclosure pursuant to the Washington State Public Records Act, Chapter 42.56 RCW as identified on the Digital Records Exemption Log shown below. PG 16-0092 MCKAY RESIDENCE 15214 SUNWOOD BLVD #3 RECORDSDIGITAL D-) EXEMPTION LOG THE ABOVE MENTIONED PERMIT FILE INCLUDES THE FOLLOWING REDACTED INFORMATION Page # Coda Exemption, � � � I3ri6f Explanatory 6escrlofion, Sfatutte/Ruilo The Privacy Act of 1974 evinces Congress' intent that social security numbers are a private concern. As such, individuals' social security Personal Information — numbers are redacted to protect those Social Security Numbers individuals' privacy pursuant to 5 U.S.C. sec. 5 U.S.C. sec. DR1 Generally — 5 U.S.C. sec. 552(a), and are also exempt from disclosure 552(a); RCW 552(a); RCW under section 42.56.070(1) of the Washington 42.56.070(1) 42.56.070(1) State Public Records Act, which exempts under the PRA records or information exempt or prohibited from disclosure under any other statute. Redactions contain Credit card numbers, debit card numbers, electronic check numbers, credit Personal Information — expiration dates, or bank or other financial RCW 10 DR2 Financial Information — account numbers, which are exempt from 42.56.230(5) RCW 42.56.230(4 5) disclosure pursuant to RCW 42.56.230(5), except when disclosure is expressly required by or governed by other law. Personal Information — Redactions contain information used to prove RCW DR3 Driver's License. — RCW identity, age, residential address, social security 42.56.230 (7a 42.56.230 number or other personal information required to & c) (7a & c) apply for a driver's license or identicard. Redacted content contains a communication between client and attorney for the purpose of obtaining or providing legal advice exempt from RCW Attorney -Client Privilege — disclosure pursuant to RCW 5.60.060(2)(a), 5.60.060(2)(a); DR4 RCW 5.60.060(2)(a); RCW which protects attorney-client privileged RCW 42.56.070(1) communications, and RCW 42.56.070(1), which 42.56.070(1) protects, under the PRA, information exempt or prohibited from disclosure under another statute. McKAY RESIENCE 15214 SUNWOOD BLVD UNITJ-3 PG16-0092 City of Tukwila • Department of Community Development • 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Inspection Request Line: 206-438-9350 Web site: http://www.TukwilaWA.Rov WATER HEATER PERMIT Parcel No: 8141400910 Permit Number: PG16-0092 Address: 15214 SUNWOOD BLVD 3 Issue Date: 7/11/2016 Permit Expires On: 1/7/2017 Project Name: MCKAY RESIDENCE Owner: 2015 National Electrical Code: Name: ARENSBERG JODEEN R % D AREN 2015 Address: 12150 SE 16TH PL, BELLEVUE, WA, International Mechanical Code Edition: 2015 98005 2014 Contact Person: 2015 WA State Energy Code: Name: GUY YOUNG Phone: (425) 828-3009 Address: 13512 NE 124 ST, KIRKLAND, WA, Permit Center Authorized Signature: 98034 _ �'� Contractor: Name: D YOUNGS PLUMBING INC Phone: (425) 828-3009 Address: 13512 NE 124 ST, KIRKLAND, WA, 98034-8010 License No: DYOUNYP976PA Expiration Date: 10/1/2017 Lender: Name: Address: DESCRIPTION OF WORK: REPLACE ELECTRIC WATER HEATER Valuation of Work: $600.00 Fees Collected: $48.83 Water District: Sewer District: Current Codes adopted by the City of Tukwila: International Building Code Edition: 2015 National Electrical Code: 2014 International Residential Code Edition: 2015 WA Cities Electrical Code: 2014 International Mechanical Code Edition: 2015 WAC 296-468: 2014 Uniform Plumbing Code Edition: 2015 WA State Energy Code: 2015 International Fuel Gas Code: 2015 Permit Center Authorized Signature: Date: _ �'� I hearby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating ! truction or the perfor nce of work. I am authorized to sign and obtain this development permit and the con ' ' ached -to this permit. Signatur Date: 14 Print Name: fn/ )AAI C J VL tl V U� - -- This permit shall become null and void if the work is not commZficed within 180 days for the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. PERMIT CONDITIONS: 1: ***PLUMBING/GAS PIPING PERMIT CONDITIONS*** 2: No changes shall be made to applicable plans and specifications unless prior approval is obtained from the Tukwila Building Division. 3: All permits, inspection records and applicable plans shall be maintained at the job and available to the plumbing inspector. 4: All plumbing and gas piping systems shall be installed in compliance with the Uniform Plumbing Code and the Fuel Gas Code. 5: No portion of any plumbing system or gas piping shall be concealed until inspected and approved. 6: All plumbing and gas piping systems shall be tested and approved as required by the Plumbing Code and Fuel Gas Code. Tests shall be conducted in the presence of the Plumbing Inspector. It shall be the duty of the holder of the permit to make sure that the work will stand the test prescribed before giving notification that the work is ready for inspection. 7: No water, soil, or waste pipe shall be installed or permitted outside of a building or in an exterior wall unless, adequate provision is made to protect such pipe from freezing. All hot and cold water pipes installed outside the conditioned space shall be insulated to minimum R-3. 8: Plastic and copper piping running through framing members to within one (1) inch of the exposed framing shall be protected by steel nail plates not less than 18 guage. 9: Piping through concrete or masonry walls shall not be subject to any load from building construction. No plumbing piping shall be directly embedded in concrete or masonry. 10: All pipes penetrating floor/ceiling assemblies and fire -resistance rated walls or partitions shall be protected in accordance with the requirements of the building code. 11: Piping in the ground shall be laid on a firm bed for its entire length. Trenches shall be backfilled in thin layers to twelve inches above the top of the piping with clean earth, which shall not contain stones, boulders, cinderfill, frozen earth, or construction debris. 12: The issuance of a permit or approval of plans and specifications shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the Plumbing Code or Fuel Gas Code or any other ordinance of the jurisdiction. 13: The applicant agrees that he or she will hire a licensed plumber to perform the work outlined in this permit. 14: All new plumbing fixtures installed in new construction and all remodeling involving replacement of plumbing fixtures in all residential, hotel, motel, school, industrial, commercial use or other occupancies that use significant quantities of water shall comply with Washington States Water Efficiency ad Conservation Standards in accordance with RCW 19.27.170 and the 2006 Uniform Plumbing Code Section 402 of Washington State Amendments PERMIT INSPECTIONS REQUIRED Permit Inspection Line: (206) 438-9350 1900 PLUMBING FINAL 8005 ROUGH -IN PLUMBING CITY OF TUKWi Community Development Department Permit Center • 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 llttp://www.TukwilaWA.Qov SITE LOCATION, Site Plumbng/Gas erm><t Q. ProiectNo-- Date' Application Accepted:_ Date Application Expires: or PLUMBING / GAS PIPING PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. "Please Print" Tenant Name: ' a W 1 6J CONTACT,'PERSJJ erson receiving all.,project c6miriumoati6n _ - � - - - Name: C e Address: City: C t �G State: ip6 3 Phone � .g Fax: a Email: �9..44 6 LJ Valuation of Project (contractor's bid price): $ LMA King Co Assessor's Tax No.: Suite Number: 'T 3 New Tenant: Floor: ❑ ..... Yes No PL-`UMAING CONTRACTOR INFORMATION, Company Name: - b �� n -J G Address: �. Iot, 7 - City: l G % State: Zip Phone: , t/ Fax: 28'3act Contr Reg No.: Exp Date: Tukwila Business License No.: Scope of Work (please provide detailed information): Igyp. r C✓i L�-tL iL Building Use (per Int'I Building Code): Occupancy (per Int'l Building Code): Utility Purveyor: Water: Sewer: H:Wpplications\Forms-Applications On Line\2011 Applications\Plumbing Permit Application Revised 8-9.1l.docx Revised: August 2011 Page 1 of 2 bh Indicate type of plumbing fixtures and/c s piping outlets being installed and the quanti low: Fixture Type Qty Bathtub or combination bath/shower Dishwasher, domestic with independent drain Shower, single head trap Sinks Rain water system — per drain (inside building) Grease interceptor for commercial kitchen (>750 gallon capacity) Each additional medical gas inlets/outlets greater than 5 Atmospheric -type vacuum breakers not included in lawn sprinkler backflow protections (1-5 Fixture Type Qty Bidet Drinking fountain or water cooler (per head) Lavatory Urinal Water heater and/or vent Repair or alteration of water piping and/or water treatment equipment Backflow protective device other than atmospheric - type vacuum breakers 2 inch (51 mm) diameter or smaller Atmospheric -type vacuum breakers not included in lawn sprinkler backflow protections over 5 PERMIT APPLICATION NOTES - Fixture Type Qty Clothes washer, domestic Food -waste grinder, commercial Wash fountain Water closet Industrial waste treatment interceptor, including trap and vent, except for kitchen type grease interceptors Repair or alteration of drainage or vent piping Backflow protective device other than atmospheric -type vacuum breakers over 2 inch (51 mm) diameter Gas piping outlets Fixture Type Qty Dental unit, cuspidor Floor drain Receptor, indirect waste Building sewer and each trailer park sewer Each grease trap (connected to not more than 4 fixtures - <750 gallon capacity Medical gas piping system serving 1-5 inlets/outlets for a specific gas Each'lawn sprinkler system on any one meter including backflow protection devices Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The Building Official may grant one extension of time for an additional period not to exceed 180 days. The extension shall be requested in writing and justifiable cause demonstrated. Section 103.4.3 International Plumbing Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER OR AUTHORIZED AGENT: &'&" " • '' _ _ '- % Signature: Date: Print Day Teleph e: Mailing Address: City State Zip H:Wpplications\Forms-Applications On Line\2011 ApplicationsTlumbing Permit Application Revised 8-9-11.docx Revised: August 2011 Page 2 of 2 bh DESCRIPTIONS PermitTRAK • QUANTITY PAID $48.83 PG16-0092 Address: 15214 SUNWOOD BLVD 3 Apn: 8141400910 $48.83 PLUMBING $46.50 PERMIT ISSUANCE BASE FEE R000.322.100.00.00 0.00 $32.50 WATER HEATER FIXTURE FEE R000.322.103.00.00 0.00 $14.00 TECHNOLOGY FEE $2.33 TECHNOLOGY FEE TOTAL FEESRECEIPT:R8919 R000.322.900.04.00 0.00 $2.33 $48.83 Date Paid: Monday, July 11, 2016 Paid By: GUY YOUNG Pay Method: CREDIT CARD 020112 Printed: Monday, July 11, 2016 1:34 PM 1 of 1 N?WSYSTEMS INSPECTION RECORD r-"') Retain a copy with permit j�,IG 40�Z INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Project: Mum ES Ty eof Inspection: I , vM 9 IW6- L Address: 15-21 tl ��&M r> i3zvD Date Called: Special Instructions: a.m. Date WantedZI 73 Atle <P775 Requester: Phone No: LApproved per applicable codes. Corrections required prior to approval. Inspector. Date: -7 REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. INSPECTION RECORD Retain a copy with permit oeL INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Project: Ty a of Inspection: nn ES !!V I AJ 1'Lv Address: R- Date Called: Z/ IJ Special Instructions: Date W nt�3// a.m lR 44i Request r: Phone No: -106-2 1=1996 Ful Approved per applicable codes. 11Corrections required prior to approval. VSL Inspector: Date: 13 REINSPECTION FEE REQUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. D YOUNGS PLUMBING INC kiWashington State Reparoent of Labor & Industries D YOUNGS PLUMBING INC Owner or tradesperson Principals YOUNG, GUY R, PRESIDENT YOUNG, DIANE LEE, VICE PRESIDENT Doing business as D YOUNGS PLUMBING INC WA UBI No. 602 250 735 License Home Espahol Contact Safety & Health Claims & Insurance 13512 NE 124TH STREET KIRKLAND, WA 98034-8010 425-828-3009 KING County Business type Corporation Page 1 of 2 Search L&I h] ; 'X-1 Index Help boy IA'1 Workplace Rights Trades & Licensing Verify the contractor's active registration / license / certification (depending on trade) and any past violations. Construction Contractor Active. Meets current requirements. License specialties $6,000.00 PLUMBING Effective date License no. 10/01/2003 DYOUNYP976PA Impaired date Effective — expiration N/A 10/01/2003-10/01/2017 Bond ................. No bond accounts during the previous 6 year period. Insurance -1-1-1- ................... Federated Mutual Ins Cc $1,000,000.00 Policy no. 9809557 Received by L&I Effective date 08/11/2015 10/01/2015 Expiration date 10/01/2016 Insurance history S.a..............vings ..... (in lieu of bond) $6,000.00 Received by L&I Effective date 10/01/2003 10/01/2003 Release date Impaired date N/A N/A Savings account ID Lawsuits against the bond or savings No lawsuits against the bond or savings accounts during the previous 6 year period. L&I Tax debts No L&I tax debts are recorded for this contractor license during the previous 6 year period, but some debts may be recorded by other agencies. https://secure.lnima.gov/verify/Detail.aspx?UBI=602250735&LIC=DYOUNYP976PA&SAW= 7/11/2016