Loading...
HomeMy WebLinkAboutPermit PG16-0123 - HUYNH RESIDENCE - WATER HEATER REPLACEMENTHUYNH RESIDENCE 15325 SUNWOOD BLVD UNIT B-301 PG16-0123 City of Tukwila • Department of Community Development • 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Inspection Request Line: 206-438-9350 Web site: http://www.TukwilaWA.gov WATER HEATER PERMIT Parcel No: 1865200450 Permit Number: PG16-0123 Address: 15325 SUNWOOD BLVD 8301 Issue Date: 8/23/2016 Permit Expires On: 2/19/2017 Project Name: HUYNH RESIDENCE Owner: Name: HUYNH VINH C Address: 15325 SUN DWOOD BLVD #B 301, SEATTLE, WA, 98188 Contact Person: Name: KATY KEHLE Address: 11715 N CREEK PKWY S #C-106, International Residential Code Edition: BOTHELL, WA, 98011 Contractor: 2014 Name: FAST WATER HEATER COMPANY Address: 11715 N CREEK PKWY S STE C-106, Uniform Plumbing Code Edition: BOTHELL, WA, 98011 License No: FASTWWH948BC Lender: Name: Address: DESCRIPTION OF WORK: REMOVE/REPLACE WATER HEATER. Valuation of Work: $1,097.00 Water District: Sewer District: Phone: (425) 636-7084 Phone: (425) 636-7084 Expiration Date: 1/4/2018 Fees Collected: $48.83 Current Codes adopted by the City of Tukwila: International Building Code Edition: 2015 National Electrical Code: 2014 International Residential Code Edition: 2015 WA Cities Electrical Code: 2014 International Mechanical Code Edition: 2015 WAC 296-466: 2014 Uniform Plumbing Code Edition: 2015 WA State Energy Code: 2015 International Fuel Gas Code: 2015 Permit Center Authorized Signature: &h&0 Date: U ��i l I hearby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this development permit and ag ee to the co ditions attached to this permit. Signature: Date: CF—. -Z-2 � Print Name:ZZ's This permit shall become null and void if the work is not commenced within 180 days for the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. PERMIT CONDITIONS: 1: `PLUMBING/GAS PIPING PERMIT CONDITIONS' 2: No changes shall be made to applicable plans and specifications unless prior approval is obtained from the Tukwila Building Division. 3: All permits, inspection records and applicable plans shall be maintained at the job and available to the plumbing inspector. . 4: All plumbing and gas piping systems shall be installed in compliance with the Uniform Plumbing Code and the Fuel Gas Code. 5: No portion of any plumbing system or gas piping shall be concealed until inspected and approved. 6: All plumbing and gas piping systems shall be tested and approved as required by the Plumbing Code and Fuel Gas Code. Tests shall be conducted in the presence of the Plumbing Inspector. It shall be the duty of the holder of the permit to make sure that the work will stand the test prescribed before giving notification that the work is ready for inspection. 7: No water, soil, or waste pipe shall be installed or permitted outside of a building or in an exterior wall unless, adequate provision is made to protect such pipe from freezing. All hot and cold water pipes installed outside the conditioned space shall be insulated to minimum R-3. 8: Plastic and copper piping running through framing members to within one (1) inch of the exposed framing shall be protected by steel nail plates not less than 18 guage. 9: Piping through concrete or masonry walls shall not be subject to any load from building construction. No plumbing piping shall be directly embedded in concrete or masonry. 10: All pipes penetrating floor/ceiling assemblies and fire -resistance rated walls or partitions shall be protected in accordance with the requirements of the building code. 11: Piping in the ground shall be laid on a firm bed for its entire length. Trenches shall be backfilled in thin layers to twelve inches above the top of the piping with clean earth, which shall not contain stones, boulders, cinderfill, frozen earth, or construction debris. 12: The issuance of a permit or approval of plans and specifications shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the Plumbing Code or Fuel Gas Code or any other ordinance of the jurisdiction. 13: The applicant agrees that he or she will hire a licensed plumber to perform the work outlined in this permit. 14: All new plumbing fixtures installed in new construction and all remodeling involving replacement of plumbing fixtures in all residential, hotel, motel, school, industrial, commercial use or other occupancies that use significant quantities of water shall comply with Washington States Water Efficiency ad Conservation Standards in accordance with RCW 19.27.170 and the 2006 Uniform Plumbing Code Section 402 of Washington State Amendments PERMIT INSPECTIONS REQUIRED Permit Inspection Line: (206) 438-9350 1900 PLUMBING FINAL 8005 ROUGH -IN PLUMBING CITY OF TUKWILA Community Developm- Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 SITE LOCATION Plumbng/G permit No. Project No. _ 'OV I Date ?application Expires: �' IX (Tor, o tce use PLUMBING / GAS PIPING PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. "Please Print" /� C r1 ' ` King Co Assessor's Tax No.: I Uq —' vv Site Address:_ ` ✓�' 1 I�C�'U` �V W�OI� j�yD Suite Number: 3301 Floor: Tenant Name: \� � �[ I Vy �i�l New Tenant: ❑..... Yes PROPERTY OWNER Name: v I i +v \4 (� (- I� 11 Address: J rl �i 1 t �'fDO yp City: TU � � A State: Zip: q g)9 CONTACT PERSON - person,.receiving all project communication Name: K ATy G L Address: 11-q- `T N C S Hwy S C' I O 1p City: lbo j l .�-tP„_t 1 (,State: W Zip: I Phone: 3(J�N-(Fax: 14� 3( D Email: KKEku_ a+fxt (t1N1 -- oL45-0 PLUMBING CONTRACTOR INF ORM AT10lV_ Company Name: fA ST Address: City: r� i,1 . l State: w� Zip: �e p Phone: l i �V�� r ^ " Fax: L. Qs (9Ij 0� Contr Reg No.: AS,TWW VAAL4%&xp Date: Tukwila Business License No.: Valuation of Project (contractor's bid price): Scope of Work (please provide detailed information): Building Use (per Int'l Building Code): Occupancy (per Int'1 Building Code): Utility Purveyor: Water: Sewer: H:\Applications\Forms-Applications On Line\2011 Applications\Plumbing Permit Application Revised 8-9-1 Ldocx Revised: August 2011 Page 1 of 2 bh Indicate type of plumbing fixtures and/or --s piping outlets being installed and the quantit- below: Fixture Type Qty Bathtub or combination bath/shower Dishwasher, domestic with independent drain Building sewer and each Shower, single head trap Sinks Rain water system — per drain (inside building) Grease interceptor for commercial kitchen (>750 gallon capacity) Each additional medical gas inlets/outlets greater than 5 Atmospheric -type vacuum breakers not included in lawn sprinkler backflow protections (1-5) Fixture Type Qty Bidet Drinking fountain or water cooler (per head) Lavatoryy Building sewer and each Urinal Water heater and/or vent Repair or alteration of water piping and/or water treatment equipment Backflow protective device other than atmospheric - type vacuum breakers 2 inch (51 mm) diameter or smaller Atmospheric -type vacuum breakers not included in lawn sprinkler backflow protections over 5 PERMIT APPLICATION NOTES Fixture Type Qty Clothes washer, domestic Food -waste grinder, commercial Building sewer and each Wash fountain Water closet Industrial waste treatment interceptor, including trap and vent, except for kitchen type grease interceptors Repair or alteration of drainage or vent piping Backflow protective device other than atmospheric -type vacuum breakers over 2 inch (51 mm) diameter Gas piping outlets Fixture Type Qty Dental unit, cuspidor Floor drain Receptor, indirect waste Building sewer and each trailer park sewer Each grease trap (connected to not more than 4 fixtures - <750 gallon capacity Medical gas piping system serving 1-5 inlets/outlets for a specific gas Each lawn sprinkler system on any one meter including backflow protection devices Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The Building Official may grant one extension of time for an additional period not to exceed 180 days. The extension shall be requested in writing and justifiable cause demonstrated. Section 103.4.3 International Plumbing Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON; AND I AM AUTHORi7FD TO APPLY FOR THIS PERMIT. BUILDING OWNER OR Signature Date: K_ Lp — 1 ((/ Print Name: K� 1� ��� �— 11 WA— d5 IQ 31 "I Mailing Address: 115 Ni �f� { KWV S C— � 6 U a Dl1T v 1 1. W A— I I City State Zip H:VApplications\Forms-Applications On Line\201 I Applications\Plumbing Permit Application Revised 8-9-11.docx Revised: August 2011 Page 2 of 2 bh DESCRIPTIONS PermitTRAK ACCOUNT QUANTITY PAID $48.83 PG16-0123 Address: 15325 SUNWOOD BLVD 8301 Apn: 1865200450 $48.83 PLUMBING $46.50 PERMIT ISSUANCE BASE FEE R000.322.100.00.00 0.00 $32.50 WATER HEATER FIXTURE FEE R000.322.103.00.00 0.00 $14.00 TECHNOLOGY FEE $2.33 TECHNOLOGY FEE y, RECEIPT: R9252 + PAID TOTAL R000.322.900.04.00 0.00 $2.33 Date Paid: Tuesday, August 23, 2016 Paid By: FAST WATER HEATER COMPANY Pay Method: CHECK 21392 Printed: Tuesday, August 23, 2016 9:35 AM 1 of 1 0?W SYSTEMS INSPECTION RECORD \0 Retain a copy with permit IT&)6- -OW& INSP N N0. PERMIT N0. CITY OF" TUKWILA BUILDING DIVISION 4t 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Proj ct: I Ty of Inspection: Address: Date Called: �0 Special Instructions:' Date Wante --a—m, -- -17 Request Phone No: Approved per applicable codes. Corrections required prior to approval. COMMENTS: Inspector: Date: f REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. INSPECTION RECORD r Retain a copy with permit �� 01 Z INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Project: - V D eg1��'&- Ty of Inspection: F '' Af"1- n/.•4L Address: Date Called: Special Instructions: 1I Date Wanted: a.m / � p.m. Requester: Phone No: 2.cJ6 /0- 2 O EJApproved per applicable codes. l _y Corrections required prior to approval. COMMENTS: REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. INSPECTION RECORDr--y y / 16 Retain a copy with permit � ' �1 23 INS CTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Proje t:Type U` ii /l eAZC: of Inspection: v9 - I'Af )9�4'ntf3Wt Address: Date Called: J57325- o'oL-)rso' Py— Special Instructions: 30I Date Wanted. a. �j 2/11-6 p.m. Requester: t/\w 1 Phone No: 2C6 29962 Approved per applicable codes. u Corrections required prior to approval. Inspector: Date: &-6121 iQ �f 1� REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. FAST WATER HEATER COMPATTv Washington State Department of Labor & Industries Page 1 of 5 Home Espanol Contact Search L&I A -L Index help My L&I Safety & Health Claims & Insurance Workplace Rights Trades & Licensing FAST WATER HEATER COMPANY Owner or tradesperson Principals JORDAN, JEFFERY DAVID, PARTNER/MEMBER HANLEYBROWN, JASON,PARTNER/MEMBER Doing business as FAST WATER HEATER COMPANY WA UBI No. 602 564 544 Parent company FWH ACQUISITION COMPANY LLC 11715 N CREEK PARKWAY S, C-106 BOTHELL, WA 98011 425-814-8381 KING County Business type Limited Liability Company Governing persons JASON HANLEYBROWN JEFFREY DAVID JORDAN; License Verify the contractor's active registration / license / certification (depending on trade) and any past violations. Construction Contractor Active. ....................................................................... Meets current requirements. License specialties GENERAL $1,000,000.00 License no. FASTWWH948BC Effective — expiration Effective date 01/0312006— 01104/2018 02/17/2014 Bond Expiration date DEVELOPERS SURETY & INDEM CO $12,000.00 Bond account no. 549792C Received by L&I Effective date 01103/2006 01/01/2005 Expiration date Until Canceled Insurance American States Insurance Co $1,000,000.00 Policy no. 01C155607620 Received by L&I Effective date 01/25/2016 02/17/2014 Expiration date 02/17/2017 Insurance history https:Hsecure.Ini.wa.gov/verify/Detail.aspx?UBI=602564544&LIC=FASTWWH948BC&SAW= 8/23/2016