Loading...
HomeMy WebLinkAboutPermit PG16-0141 - NW HYDRAULICS - WASTE, VENT, POTABLE HOT/COLD WATER ETCNW HYDRAULICS 12787 GATEWAY DR PG16-0141 City of Tukwila •� Department of Community Development • 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Inspection Request Line: 206-438-9350 Web site: http://www.TukwilaWA.Rov PLUMBING/GAS PIPING PERMIT Parcel No: 2716000060 Permit Number: PG16-0141 Address: 12787 GATEWAY DR Issue Date: 10/3/2016 Permit Expires On: 4/1/2017 Project Name: NW HYDRAULICS Owner: Name: EPROPERTY TAX INC DEPT #207 Address: PO BOX 4900, SCOTTSDALE, WA, 85261 Contact Person: 2015 Name: GREG SMALLING Address: PO BOX 1917, RENTON, WA, 98057 Contractor: 2014 Name: GS MECHANICAL LLC Address: PO BOX 65, REDMOND, WA, 98073 License No: GSMECML928RK Lender: 2015 Name: 2015 Phone: (206) 372-0332 Phone: (206) 372-0332 Expiration Date: 12/12/2016 Address: , , , DESCRIPTION OF WORK: WASTE, VENT & POTABLE HOT & COLD WATER FOR (2) ADA SHOWER STALLS (2) UTILITY TUBS (1) EYE WASH (2) HOSE BIBS & (1) 50 GALLONG ELECTRIC WATER HEATER Valuation of Work: $5,000.00 Fees Collected: $199.56 Water District: TUKWILA Sewer District: TUKWILA Current Codes adopted by the City of Tukwila: International Building Code Edition: 2015 National Electrical Code: 2014 International Residential Code Edition: 2015 WA Cities Electrical Code: 2014 International Mechanical Code Edition: 2015 WAC 296-466: 2014 Uniform Plumbing Code Edition: 2015 WA State Energy Code: 2015 International Fuel Gas Code: 2015 —3 Permit Center Authorized Signature: Date: I hearby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this development permit and agree to the conditio attached to this permit. 1 Signature: 4Date:` Print Name: ��/121 tJ lill/ /_/ This permit shall become null and void if the work is not commenced within 180 days for the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. PERMIT CONDITIONS: 1: ***PUBLIC WORKS PERMIT CONDITIONS*** 2: Prior to issuance of this permit Owner/Representative shall sign a completed King County Non -Residential Sewer Use Certification. 3: ***PLUMBING/GAS PIPING PERMIT CONDITIONS*** 4: No changes shall be made to applicable plans and specifications unless prior approval is obtained from the Tukwila Building Division. S: All permits, inspection records and applicable plans shall be maintained at the job and available to the plumbing inspector. 6: All plumbing and gas piping systems shall be installed in compliance with the Uniform Plumbing Code and the Fuel Gas Code. 7: No portion of any plumbing system or gas piping shall be concealed until inspected and approved. 8: All plumbing and gas piping systems shall be tested and approved as required by the Plumbing Code and Fuel Gas Code. Tests shall be conducted in the presence of the Plumbing Inspector. It shall be the duty of the holder of the permit to make sure that the work will stand the test prescribed before giving notification that the work is ready for inspection. 9: No water, soil, or waste pipe shall be installed or permitted outside of a building or in an exterior wall unless, adequate provision is made to protect such pipe from freezing. All hot and cold water pipes installed outside the conditioned space shall be insulated to minimum R-3. 10: Plastic and copper piping running through framing members to within one (1) inch of the exposed framing shall be protected by steel nail plates not less than 18 guage. 11: Piping through concrete or masonry walls shall not be subject to any load from building construction. No plumbing piping shall be directly embedded in concrete or masonry. 12: All pipes penetrating floor/ceiling assemblies and fire -resistance rated walls or partitions shall be protected in accordance with the requirements of the building code. 13: Piping in the ground shall be laid on a firm bed for its entire length. Trenches shall be backfilled in thin layers to twelve inches above the top of the piping with clean earth, which shall not contain stones, boulders, cinderfill, frozen earth, or construction debris. 14: The issuance of a permit or approval of plans and specifications shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the Plumbing Code or Fuel Gas Code or any other ordinance of the jurisdiction. 15: The applicant agrees that he or she will hire a licensed plumber to perform the work outlined in this permit. 16: All new plumbing fixtures installed in new construction and all remodeling involving replacement of plumbing fixtures in all residential, hotel, motel, school, industrial, commercial use or other occupancies that use significant quantities of water shall comply with Washington States Water Efficiency ad Conservation Standards in accordance with RCW 19.27.170 and the 2006 Uniform Plumbing Code Section 402 of Washington State Amendments PERMIT INSPECTIONS REQUIRED Permit Inspection Line: (206) 438-9350 8004 'GROUNDWORK 1900 PLUMBING FINAL 8005 ROUGH -IN PLUMBING ITY Coinmunity Development DepnHment 1'ernrii Genlei- • 6300 Southcentei- 8/vd.„ Suite .100 Thin, ila, IPA 98.188 " bttp:flx„nww.TuklwilaW.A,gov 1'Jtttt7bin1;/Cytts .1'errttit \tt.�� Project No. Date Application Accepted: Y . Date Application Expires: (For office use onl}) PLUMI BINE / GAS PIPING PERMIT APPLICATH N Applications and plans must be complete in order to be accepted for plan rcvictie Applications .will not be accepted through the mail or by fax. "Please Print” SITE LOCA'T'ION Kine Co Assessor's Tax No.: 271600-0060 Site Address: 1.2787 Gateway Drive Suite Number: Bldg 6 'Floor: 1 `I`enantNa'me: NW Hydraulics New Tenant: W .....Yes ❑..No PROPERTY OWNER Natne: Kidder MatheAvs Address: 12886 interurban Ave S City: Seattle State: WA Zip: 98168 CONTACT PERSON — person receiving all project communication Name: Greg Smalling Address: PO Box 65 City; Redmond State: WA Z p: 98073 Phone: (206) 372-0332 Fax: Email. greg@gstnechanicalsirop.com PLUMBING CONTRACTOR INFORMATION Company Name: GS Mechanical Address: 170 Box 65 City: Redmond State: WA Zip: 98073 Phone: (206) 372-0332 Yax: COntr:lte9No.: GSMF.CML928;RK Exp Tate: 1.2112/2016 TulcNvila Business Licensc No.: BUS -0993293 Valuation of Project (contractor's bid price): $ 5.000 Scope of Work {please 1)rovide detailed information): Waste, vent & potable bat & cold water for (2) ATA shower stalls, (2) utility tubs, (1) eye wash, (2) hose bibs & (1) 50 gallon electric water beater. Building Use (per lttt'l Building Code): Occupancy (per Intl :Building Code): Utility Purveyor: Water: WAG 51-50 B - Business Sewer: 1I:.Applim;oae,,Fanns-Appliprion On UneW01 i App6c31;0mV1UMbin9 Permit Application Recited 8.9.11.doex Rnised: August 2011 Page I of 2 bb Indicate type of plumbing fixtures and/or gas piping outlets being installed and the quantity below: ;Fixture pipe Qh Bathtub or combination bathlshowcr Dishwasher' domestic .Nitb independent drain Shower. single bead tnp 2 Sinks 2 Rain water system — per drain (inside building) Grease interceptor for commercial kitchen (7750 gallon capacity) Each additionnlmcilical gas inlets/outlets greater than 5 Atmospheric -type vacuum breakers not included in lawn sprinkler backflow Protections (1-5) Fixture Type Qtv ,Bidet Drinking fountain or titter cool er (per head) Lavatory Urinal Water heater and/or vent ,Repair or alteration of water piping and/or mater treatment equipment iBaclkflow protective device other than atmospheric - type vacuum breakers 2 inch (51 mm) diameter or smaller Almosphcric-type vacuum breakers not included in lawn sprinkler backflow protections over 5 FixtureType Qty Clothes washer. domestic Food -waste grinder, commercial !'gash fountain Water closet Industrial waste treatment in lcrceptor, including trap and vent, except for kitchen type grease interceptors Repair or alteration of drainage or vent piping Backflow protective device other than al'mosplicrie-type vacuum breakers over 2 inch (5) turn) diameter Cas piping millets Fixture Type Qty Dental unit, cuspidor )Floor drain Receptor. indirect Waste .Building sewer and each trailer park sewer Facb grease trap (connecled to notnlore than 4 fixtures - <750 gallon capacity Medical ,gas piping systent serving 1-5 inlets1t utlets for a specific gas Each lawn sprinkler ;system on any one ureter including backhow protection devices PERM IT A PPLICATION NOTES - Value of Construction —Ill all lases, a vArae of constnicrioiiamount should be entered by the applicant. Tliis figure %vil:l be reviewed and is subject to possible revision by the Permit Center to comply ,.Ath current fee schedules. Expiration of Plan Review —Applications for which ito permit is issued within 180 days following the date of application shall expire by .limitation. Ile Building Official may grant one extension of time for an additional period not to exceed 180 days. The extension shall be requested in writing and justifiable cause demonstrated. Section 103.4.3 International Plumbing Code (current edition). I HEREBY CERTIFY TBAT I IJAVE READ AND E)AMINED THIS APPLICATION AND KNOW TIME SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM'AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING 011rNT,1R OR AUTHORIZE D AGENT: Pl-intName: Greg Smalling Mailing Address: PO Box 65 Day Telephone: Redmond City 'Date: --lqi -- /6 (2416) 372-0332 `WA 93073 stat tin HAApplicatione Fomro-Applicafion; On Mne12011 Applications. lumbinF Permft Al". licolrnn Re.lsed 8A.1 l.daes Re. iced: Augnn Znl 1 Page 2 of 2 bit DESCRIPTIONS PermitTRAK ACCOUNT QUANTITY PAID $199.56 PG16-0141 Address: 12787 GATEWAY DR Apn: 2716000060 $199.56 PLUMBING $191.88 PERMIT ISSUANCE BASE FEE R000.322.100.00.00 0.00 $32.50 PERMIT FEE R000.322.100.00.00 0.00 $121.00 PLAN CHECK FEE R000.322.103.00.00 0.00 $38.38 TECHNOLOGY FEE $7.68 TECHNOLOGY FEE TOTAL FEES PAID BY RECEIPT: .. R000.322.900.04.00 0.00 $7.68 $199.56 Date Paid: Monday, September 19, 2016 Paid By: GREG SMALLING Pay Method: CREDIT CARD 219183 Printed: Monday, September 19, 2016 10:38 AM 1 of 1 SYSTEMS INSPECTION RECORD Retain a copy with permit %)6, `01q 1j INSPECTION NO. PERMIT NO. CITY OF' TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-36 Permit Inspection Request Line (206) 438-9350 Project: ��a� -QZJC - Typ Inspection: um(3i SAI L Address: i2?i'Z?b07 6AM&AY`D Date Called: Special Instructions: Date Wanted: m. % 17 .m. Requester: Phone No: Approved per applicable codes. LJ Corrections required prior to approval. �' paid at 6300 Southcenter 8\d., Suite 100. Call to schedule reinspection. INSPECTION RECORD -C Retain a copy with permit 1�&16 INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 ProjeJc�: Tle Inspectio`n: �of� Address: 2?, 7?�re Date Called: Special Instructions: Date Wan ed: a.m. / 17 Reques -• Phone No: q 2- MApproved per applicable codes. 11 Corrections required prior to approval. Inspector: Date: REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Approved per applicable codes. 11 Corrections required prior to approval. IInspector: /-bAra - IDate: /Oh/ El REINSPECTION FEE REQUIRED. Prior to next inspedlion.'fee must be paid at 6300 Southcenter Blvd.. Suite 100. Calt to schedule reinspection. INSPECTION RECORD Retain a copy with permit � 010 INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Project: a Typ of Inspection: mu?,jDt oye K Ahi i u Address: Z796,Arcw;4,-1 '1W Date Called: Special Instructions: Date Wanted. a.m. Request/ear: "IA�� Phone No: S 72- RApproved per applicable codes. lJ Corrections required prior to approval. REINSPECTION FEE REQUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. ?ERMIT COORD COPY PLAN REVIEW/ROUTING SLIP PERMIT NUMBER: PG16-0141 DATE: 09/26/16 I PROJECT NAME: NW HYDRAULICS SITE ADDRESS: 12787 GATEWAY DR X Original Plan Submittal Response to Correction Letter # Revision # before Permit Issued Revision # after Permit Issued DEPARTMENTS: Building Division awl Fire Prevention ❑ Planning Division ❑ Pu61i� Works Structural F-1Permit Coordinator PRELIMINARY REVIEW: DATE: 09/27/16 Not Applicable ❑ Structural Review Required ❑ (no approval/review required) REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: Approved Corrections Required ❑ (corrections entered in Reviews) Notation: DUE DATE: 10/25/16 Approved with Conditions Denied ❑ (ie: Zoning Issues) REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: 12/18/2013 GS MECHANICAL LLC Home Espanol Contact Safety & Health ✓^ Washington State Department of "Labor & Industries GS MECHANICAL LLC Owner or tradesperson Principals SMALLING, GREG, PARTNER/MEMBER SMALLING, GARY, PARTNER/MEMBER Doing business as GS MECHANICAL LLC Page 1 of 2 Search L&I A -'L Index 1-lelp MyL&I Claims & Insurance Workplace Rights Trades & Licensing PO BOX 65 REDMOND, WA 98073-0065 206-372-0332 KING County WA UBI No. Business type 602 564 160 Limited Liability Company Governing persons GARY L SMALLING GREG SMALLING; License Verify the contractor's active registration / license / certification (depending on trade) and any past violations. ConstructionContractor Active. .......................................................... Meets current requirements. License specialties GENERAL $1,000,000.00 License no. GSMECML928RK Effective — expiration Effective date 12/12/2008-12/12/2016 02/27/2016 Bond ............ Expiration date CBIC $12,000.00 Bond account no. S11307 Received by L&I Effective date 12/12/2008 12/09/2008 Expiration date Until Canceled Insurance Ohio Security Ins Co $1,000,000.00 Policy no. BKS53764777 Received by L&I Effective date 03/14/2016 02/27/2016 Expiration date 02/27/2017 Insurance history Savings No savings accounts during the previous 6 year period. Lawsuits against the bond or savings https://secure.Ini.wa.gov/verify/Detail.aspx?UBI=602564160&LIC=GSMECML928RK&SAW= Help us improve 10/3/2016 T U z Ln L0 11 �Ow-teway y 4-4 6 Floor Conv%orate Cena&ter Site Plan Scale: 7 z Deferred Submittals: Drawing Index: BUILDING 2015 INTERNATIONAL BLDG CODE (IBC), Sheet Number Sheet Title AAFr NAMI(`AI PFPAAIT FIRF Al ARRA CYCTFM FIRE CODE 2015 INTERNATIONAL FIRE CODE (IFC), ELECTRICAL PERMIT PLUMBING PERMIT FIRE SPRINKLER SYSTEM • DOCUMENTS FOR DEFERRED SUBMITTAL ITEMS SHALL BE SUBMITTED TO THE REGISTERED DESIGN PROFESSIONAL IN CHARGE (ARCHITECT/ENGINEER OF RECORD) FOR REVIEW PRIOR TO SUBMITTAL TO THE BUILDING OFFICIAL. • NO WORK SHALL PROCEED ON ANY DEFERRED SUBMITTAL ITEMS UNTIL THE DOCUMENTS HAVE BEEN APPROVED BY THE BUILDING OFFICIAL AND PERMIT OBTAINED. P-0.0 PLUMBING PLAN COVER SHEET P-1.1 DEMOLITION PLAN P-1.2 PLUMBING FLOOR PLAN FILE COPY Permit No.2 N P L t r'RIAT Pla" review approval is subject to errors and omissions. I is REr�s -��D FOR; . SII `E Approval of construction documents does not authorize Mechanical the violation of any adapted code or ordinance. Receipt 0-161ectrical of approved Field Copy and co itions is acknow 0 P umbing ledged: i; bas Poing By: Cibi of Tukwila Date: «� WILDING DIVISION City Of Tukwila BUILDING DIVISION Code Information: PROJECT ADDRESS: APPLICABLE IT N 0 B IL N C BLDG 6 — FLOOR 1 12787 GATEWAY DR. BUILDING 2015 INTERNATIONAL BLDG CODE (IBC), CODE WAC 51-50 TUKWILA, WA 98168 FIRE CODE 2015 INTERNATIONAL FIRE CODE (IFC), INCL. APPENDIX B&C CONSTRUCTION TYPE: ENERGY COD 2615 WASHINGTON STATE ENERGY CODE II—B V) LU z (WSEC), WAC 51-11 STANDARD NFPA 13 m o C:) 00 o, MECHANICAL 2015 INTERNATIONAL MECHANICAL CODE (IMC), ZONE: CODE WAC 51-52 C/LI ELECTRICAL 2015 NATIONAL ELECTRICAL CODE (NEC) (NFPA OCCUPANCY: CODE 70) + PART 1 AND PART 3, WASHINGTON B — BUSINESS CITIES ELECTRICAL CODE WITH APPLICABLE RW 19.28 & WAC 296-468 TENANT SQUARE FOOTAGE: PLUMBING 2015 UNIFORM PLUMBING CODE (UPC), WAC (area of work) CODE 51-56 & 51-57 INCL. APPENDIX CHAPTERS H 16,000 SF & L — EXCL. SECTIONS L5—L7 & "LAWN SPRINKLER HEAD" FROM TABLE 6-4 OF LAND AREA APPENDIX L 115,478 SQ. FT. ZONING COD CITY OF TUKWILA 2.65 ACRES ACCESSIBILI 2009 ICC/ANSI Al 17.1 ACCESSIBLE AND CODE USABLE BUILDINGS AND FACILITIES Al Legal uescr tion: TAX PARCEL #: 271600-0060 NE -15-23-4 GATEWAY CORP. CENTER PLATE LOT. 6 VicinityMap: Pr UjVL;L 1111161111a No changes shall be made to the scope of work without prior approval of Ttlkwila Building Division. tl'OT':: Rl-vision5 will require a now plan submittal and may include additional plan review fees. Property Manager: Architect: KIDDER MATHEWS JPC ARCHITECTS, PLLC 12886 INTERURBAN AVE S 909 112TH AVE NE SUITE 206 SEATTLE, WA 98168 BELLEVUE, WA 98004 (206) 248-7328 (425) 641-9200 JIM KIDDER Jkidder@kiddermathews.com Tenant: NORTHWEST HYDRAULICS 12787 GATEWAY DRIVE TUKWILA, WA 98168 (206) 241-6000 TODD BENNETT tbennett@nhcweb.com Construction Manager: FLINN FERGUSON (206) 626-0888 MIKE DUFFY mike@finnferguson.com CHRIS ACKERMAN — EXT. 303 ChrisA@jpcarchitects.com DAN BUTLER — EXT. 326 DanB@jpcarchitects.com General Contractor: FOUSHEE & ASSOCIATES, INC. 3260 118TH AVE. SE BELLEVUE, WA 98004 RECEIV D CITY OF TUIWIL OVER SHEET NW Hydraulics Gateway Corp. Ctr. Bldg 6 1st Floor 12787 Gateway Dr Tukwila, WA 98168 DESIGN JPC DRAWN GB CHECKED CA NO. 16-0427 REGISTERED RCHITECT Z IEL H. BUTLEROF WASHINGTON 7.12.2016 Permit Review Set 7.19.2016 Issue for Permit 0 8.19.2016 Permit Rev 1/CD Set Greg Smalling Owner AECHAM Commercial Plumbing Heating and Gas Piping GS MECHANICAL, LLC New Address: POBox65 Redmond,WA98073-0065 Phone 206 372 0332 greg@gsmechankaishop.com MMN STAMP PLUMBING PLAN LIC. NO: CCFOUSHAC1580D JASON FERLEMAN (425) 746-1000 JFERLEMAN@FOUSHEE.COM SEP 19 PERMIT CEIIITER ml% PLLC 140 0 ry V) LU z m o C:) 00 o, Q s Q � 4 -J N �I NW Hydraulics Gateway Corp. Ctr. Bldg 6 1st Floor 12787 Gateway Dr Tukwila, WA 98168 DESIGN JPC DRAWN GB CHECKED CA NO. 16-0427 REGISTERED RCHITECT Z IEL H. BUTLEROF WASHINGTON 7.12.2016 Permit Review Set 7.19.2016 Issue for Permit 0 8.19.2016 Permit Rev 1/CD Set Greg Smalling Owner AECHAM Commercial Plumbing Heating and Gas Piping GS MECHANICAL, LLC New Address: POBox65 Redmond,WA98073-0065 Phone 206 372 0332 greg@gsmechankaishop.com MMN STAMP PLUMBING PLAN LIC. NO: CCFOUSHAC1580D JASON FERLEMAN (425) 746-1000 JFERLEMAN@FOUSHEE.COM SEP 19 PERMIT CEIIITER ml% PLLC N M CL a �o s Y \ U � Q (n 00 K 2 Oj U E 0 o o0 �--__� __ — — — — =1--- ---. � I II II II II II II IL---------�� —ll IT- � II L II I j 8 TYP. –9 —-----------II----------�--- —SIJ -------------------��--- 5 TYP. [-QTYP. I I I I I I I I I I I I I I I I I I I I I I I I I 0 ✓II II II II II II I � Demolition Plan eq6 ) Scale: 1/8"=l'–O" Key Notes: O NO WORK THIS AREA UNLESS OTHERWISE INDICATED. REFER TO FLOOR PLAN FOR ADDITIONAL INFORMATION. O ROLL–UP, BAG, AND PROTECT EXISTING EXTERIOR WINDOW SHADES. REPAIR AND/OR PROVIDE NEW WHERE FOUND MISSING OR DAMAGED. O DEMOLISH ALL EXISTING FINISH FLOORING AND BASE, UNLESS NOTED OTHERWISE. PATCH AND REPAIR AFFECTED SUBSTRATE AS REQUIRED. FOR INSTALLATION OF NEW FINISH FLOORING AND BASE MATERIALS REFER TO FLOOR AND FINISH PLAN FOR ADDITIONAL INFORMATION. ® DEMOLISH EXISTING PARTITION AND WALLS (PARTIAL, GRID AND FULL HEIGHT) PROTECT EXISTING ADJACENT SURFACES, INCLUDING BUT NOT LIMITED TO CEILING, ADJACENT WALLS AND FLOORING. O SALVAGE ALL REMOVED DOORS FRAMES AND RELITES FOR RE–USE OR RETURN TO BLDG. STOCK, UNLESS DIRECTED OTHERWISE © SALVAGE EXISTING FIRE EXTINGUISHLR/CABINETS FOR RELOCATION. CONTRACTOR TO FIELD VERIFY AND COORDINATE WITH ARCHITECT. O7 DEMOLISH AND DISPOSE OF EXISTING CABINETRY/MILLWORK (UNLESS OTHERWISE NOTE TO BE RETAINED). TERMINATE AND CAP ALL EXISTING SUPPLY/WASTE LINES BEHIND WALL AND/OR FLOOR. PATCH AND REPAIR AFFECTED AREAS, INCLUDING BUT NOT LIMITED TO WALLS, FLOORS, AND CEILINGS AS REQUIRED. ® DEMOLISH ELECTRICAL, LOW VOLTAGE AND LIFE SAFETY DEVICES AS REQUIRED DUE TO DEMOLITION. AT LOCATIONS WHERE ELECTRICAL IS TO BE REMOVED, TERMINATE WIRING AT CLOSEST JUNCTION BOX OR DEMOLISH WIRING BACK TO PANEL. 0 DEMOLISH AND DISPOSE OF EXISTING INSULATION BOARD AND K–FOIL FROM EXISTING OPENING. PREP FOR NEW O.H. GARAGE DOOR INSTALLATION. 10 DEMOLISH AND DISPOSE OF EXISTING EXTERIOR ALUMINUM STOREFRONT WINDOWS. PREP FOR NEW OVERHEAD GARAGE DOOR INSTALLATION. 11 12 13 REMOVE EXISTING MOP SINK AND HOT WATER TANK. SALVAGE FOR REUSE IF POSSIBLE. 14 REMOVE EXISTING TOILET PARTITION DOOR AND PARTIALLY DEMO AND RECONFIGURE TOILET COMPARTMENT STALLS FOR NEW PLAN LAYOUT. SEE FLOOR PLAN. 15 REMOVE PORTION OF EXISTING VINYL TILE FLOOR. REFER TO NEW FLOOR PLAN FOR ADDITIONAL INFORMATION. 1 g REMOVE PORTION OF EXISTING CARPET FLOORING. REFER TO NEW FLOOR PLAN FOR ADDITIONAL INFORMATION. REMOVE EXISTING VINYL FLOORING. REFER TO NEW FLOOR PLAN FOR ADDITIONAL INFORMATION. IPartition Legend: I EXISTING PARTITION/CONSTRUCTION TO REMAIN EXISTING PARTITION TO BE REMOVED EXISTING SHELL & CORE WALLS TO REMAIN REVIEWED FOR CODE COMPLIANCE APPROVED SEP 2 9 2016 Oita' of Tukwila BUILDING DIVISION NW Hydraulics Gateway Corp. Ctr. Bldg 6 1st Floor 12787 Gateway Dr Tukwila, WA 98168 DESIGN JPC DRAWN GB CHECKED CA NO. 16-0427 REGISTERED RCHITECT DANIEL H. BUTLER STATE OF WASHINGTON 7.12.2016 Permit Review Set 7.19.2016 Issue for Permit A 8.19.2016 Permit Rev 1/CD Set Greg Smalling Owner Comrraerciol Plumbing� Heating end Gas Pring GS MECHANICAL, LLC New Address: P08ox65 Redmond.WASS073-0065 Phone 206 372 0331 greg@gsmechanicalshop.com Demolition Plan RECEIVD CITY OF TU ILA SEP 19216 PERMIT CEfER p.1 . © 2016, JPC Architects, PLLC -O O N N Cn w z -I- O C:) 00 Cr_ m Q _ Q N N WMI 01- 0-m NW Hydraulics Gateway Corp. Ctr. Bldg 6 1st Floor 12787 Gateway Dr Tukwila, WA 98168 DESIGN JPC DRAWN GB CHECKED CA NO. 16-0427 REGISTERED RCHITECT DANIEL H. BUTLER STATE OF WASHINGTON 7.12.2016 Permit Review Set 7.19.2016 Issue for Permit A 8.19.2016 Permit Rev 1/CD Set Greg Smalling Owner Comrraerciol Plumbing� Heating end Gas Pring GS MECHANICAL, LLC New Address: P08ox65 Redmond.WASS073-0065 Phone 206 372 0331 greg@gsmechanicalshop.com Demolition Plan RECEIVD CITY OF TU ILA SEP 19216 PERMIT CEfER p.1 . © 2016, JPC Architects, PLLC N U � a o 0- 0- I�1 I i IF —IF -11 EQUIPMENT STORAGE 1 OPEN OFFICE 1 115 117 1 8X8 WS 1 8X8 WS 11 lL LL— HALL HALL 1 jj 1 114 RB -1 113 SYH PRIVATE PRIVATE PRIVATE LOCATION 041) PRIVATE OFFICE OFFICE OFFICE ............. ......... _......... 119 116 118 120 PRIVATE I ..... .. CP P . OFFICE COPY/PRINT FILE /MAIL...............................RB S 113 PRIV TE OFFICE 137 PRIVATE OFFICE 136 -- —— i STORE GE TOOL 12 I JAN. -IT 123 HWT 3/4"CW UT -1 o �- 126 — — — 3/4'HW C I BREA ROOM 1 124 , - - -R ET' PRIVATE PRIVATE OFFICE OFFICE 135 1 134 PL.U'"''« LNG FIXTURE ;BCH MUL. SYH arr MULTIPURPOSE RIDOW:.:.:. LOCATION 041) PRIVATE v .............. ............. ......... _......... 119 OFFICE PRIVATE OFFICE 112 128 I ..... .. CP P . ;: COPY/PRINT FILE /MAIL...............................RB S 2 1 1 . :H Z a � C �1- O O 00 � CONFERENCE.-- CONFER N_ C..E 111 :. . ............................. . * * 107 ....... ..:..:.:..:... .:...:..:. :. :-- -PRIVATE OFFICE Labs t ......._......._.... . ..... . ... ... -..... ..-... - — - - ProAo AFX75pC ,Lead Law Compliant z 2 Eyewash Wall Mounted Lab 8 Tye■rr PRIV TE OFFICE 137 PRIVATE OFFICE 136 -- —— i STORE GE TOOL 12 I JAN. -IT 123 HWT 3/4"CW UT -1 o �- 126 — — — 3/4'HW C I BREA ROOM 1 124 , - - -R ET' PRIVATE PRIVATE OFFICE OFFICE 135 1 134 PL.U'"''« LNG FIXTURE ;BCH MUL. SYH arr 109 LOCATION 041) PRIVATE v .............. ............. ......... _......... ......... .......... ...... _. _......- ...... OFFICE 128 0 -:. . 108...... 1 HB -1 i JARGE-' Z a � C �1- O O 00 � CONFERENCE.-- CONFER N_ C..E ----n' --- - ------ ..... .. .......... 107 ....... ..:..:.:..:... .:...:..:. :. :-- Hose Bib Labs t ......._......._.... .E.... PRIVATE ProAo AFX75pC ,Lead Law Compliant z 2 Eyewash Wall Mounted Lab 20 Tye■rr OFFICE Fixture: Furnished by owner OT -2 2 OtIIItYTub 106 20 a 1/2.. 212" Fixture- Mustee 17F OtIlaTub HALL 104 I SH -1 2 Shower Shower-R-pom 20 3120 P.::: PRIVATE OFFICE PRIVATE HWT--1 T Water Heater 2 103 OFFICE S40 mfr Fixture- 40 Smith ECT -50 105 PRIV TE OFFICE 137 PRIVATE OFFICE 136 -- —— i STORE GE TOOL 12 I JAN. -IT 123 HWT 3/4"CW UT -1 o �- 126 — — — 3/4'HW C I BREA ROOM 1 124 , - - -R ET' PRIVATE PRIVATE OFFICE OFFICE 135 1 134 PL.U'"''« LNG FIXTURE ;BCH MUL. SYH arr fqxTUFM LOCATION 041) W v CW 144 SPMCIRCATION + 128 0 C UT -1 NO O N N 1 HB -1 i Z a � C �1- O O 00 � N s HB -2 2 Hose Bib Labs m ProAo AFX75pC ,Lead Law Compliant EW -2 2 Eyewash Wall Mounted Lab 20 Tye■rr (E) 1-1/2" CW Fixture: Furnished by owner OT -2 2 OtIIItYTub Labitor 20 Tye„ 1/2.. 212" Fixture- Mustee 17F OtIlaTub LAB I SH -1 2 Shower Shower-R-pom 20 3120 45■ V2 Fixture- Fiber -Fab 98-1 CAE)A) wl pelta T -),H2000 shower valve 4- slide rail HWT--1 T Water Heater Janitor S40 mfr Fixture- 40 Smith ECT -50 r-x—x—x—x—x—x—x—x—x—x—x- X �x f ENCLQIIOURE I i I I EW -1 AREA OF WORK 128 0 C UT -1 NO O N N 1 HB -1 i Z a � C �1- O O 00 � N s 1 1"CW 6 m 6 m EXIST. 1 WOMEN'S (E) 1-1/2" CW - � -----4------ - - - - - -- ----- - - - - -- --- -�---- LAB I 140 �3/4"CW — { HB -1 SERVER )RAGE. LI f��RY 129 PLOTTER/ LIBRARY 130 PRIVATE OFFICE 131 PRIVATE OFFICE 132 PRIVATE OFFICE 133 1/2"U'T = 1r2` EC+1-1 HB -1 1 EXPANSION TANK ON INLET SIDE. PLUMBIr SCALE: NOT TO SCALE 1,2" £1T-1 Zlf4-1f r GL F;xci 1/2" HB -1 I✓ u Enlarged Restroom Plan scale: 4'-0' FOLDING OR FIXED SEATS _ L"I�II'all �d"r,1:I7a: NOTE: HAND-HELD SHOWERS ARE REQUIRED IN ACCESSIBLE SHOWERS. IB` VERTICAL GRAB BAR 4' VAX FROM SHOWER ENTRY (SEE ELEVATION) NOTE: VMEN EQUIPPED WITH A FOLDING SEAT, THE TRANSFER SHOWER COMPARTNENr MAY HAVE A THRESHOLD 2' ►tAX WHERE EXISTING CONDMONS WILL NOT ALLOW ALTERATIONS INTO A STRUCTURAL SLAB. Enlarged Shower Plan CONTROLS SHALL BE LOCATED WITHIN 15' LEFT OR RIGHT OF CENLERUNE OF THE SEAT PER ICC A117 SECTION 608.5.1. m I J cc Lail LaM i ='idn � Ln -r � {�gipp UQ NOTE: MUD -HELD SHOWERS ARE REQUIRED IN ACCESSIOLE SHOWERS. BUILDING STANDARD ADA GRAB BARS �-11,151 4T" Pw PER coin HWT-1 PIPING DIAGRAM I I I N.T.S. - 4 N V.T.R. PLUMBING WASTE & VEN RISER FOR \ ` 'CQa�PPRaVEIaNCE II I 1 wco 2`y SEP 2 9 2016 [V + n I �4sq we BS \ From cel Cit' Of Tukwfa WCO 2" Restrooms `II `+v BUILDING D(WSIO 2" EW -1 2" OT -1 II 41f (JT -2 / - sH 1 I I r 4b i i la's x 1!2 SAN WCO 2" SH 1 3" Connect at existing Floor clean out orYj Pstrooms. Field verIFY V) NO O N N to W Z a � C �1- O O 00 � N s N 6 m 6 m Gateway Corp. Ctr. Bldg 6 1 st Floor 12787 Gateway Dr Tukwila, WA 98168 DESIGN JPC DRAWN GB CHECKED CA NO. 16-0427 REGISTERED RCHITECT DANIEL H. BUTLER STATE OF WASHINGTON 7.12.2016 Permit Review Set 7.19.2016 Issue for Permit Qi 8.19.2016 Permit Rev 1/CD Set Greg Smalling Owner ECHANICAL Commercial Plumbing, Heating and Gas Piping GS MECHANICAL, LLC New Address: P0E3ox65 Redmond,WA99073-0065 Phone 206 372 0332 rreilia'%¢sm ech aniG0lshob.COn1 PLUMBING FLOOR PLAN RECEIVED �ITY OF TUKWILA SEP 19 2016 PERMIT CENf?P,1 .2 © 2016, JPC Architects, PLLC T U z Ln L0 11 �Ow-teway y 4-4 6 Floor Conv%orate Cena&ter Site Plan Scale: 7 z Deferred Submittals: Drawing Index: BUILDING 2015 INTERNATIONAL BLDG CODE (IBC), Sheet Number Sheet Title AAFr NAMI(`AI PFPAAIT FIRF Al ARRA CYCTFM FIRE CODE 2015 INTERNATIONAL FIRE CODE (IFC), ELECTRICAL PERMIT PLUMBING PERMIT FIRE SPRINKLER SYSTEM • DOCUMENTS FOR DEFERRED SUBMITTAL ITEMS SHALL BE SUBMITTED TO THE REGISTERED DESIGN PROFESSIONAL IN CHARGE (ARCHITECT/ENGINEER OF RECORD) FOR REVIEW PRIOR TO SUBMITTAL TO THE BUILDING OFFICIAL. • NO WORK SHALL PROCEED ON ANY DEFERRED SUBMITTAL ITEMS UNTIL THE DOCUMENTS HAVE BEEN APPROVED BY THE BUILDING OFFICIAL AND PERMIT OBTAINED. P-0.0 PLUMBING PLAN COVER SHEET P-1.1 DEMOLITION PLAN P-1.2 PLUMBING FLOOR PLAN FILE COPY Permit No.2 N P L t r'RIAT Pla" review approval is subject to errors and omissions. I is REr�s -��D FOR; . SII `E Approval of construction documents does not authorize Mechanical the violation of any adapted code or ordinance. Receipt 0-161ectrical of approved Field Copy and co itions is acknow 0 P umbing ledged: i; bas Poing By: Cibi of Tukwila Date: «� WILDING DIVISION City Of Tukwila BUILDING DIVISION Code Information: PROJECT ADDRESS: APPLICABLE IT N 0 B IL N C BLDG 6 — FLOOR 1 12787 GATEWAY DR. BUILDING 2015 INTERNATIONAL BLDG CODE (IBC), CODE WAC 51-50 TUKWILA, WA 98168 FIRE CODE 2015 INTERNATIONAL FIRE CODE (IFC), INCL. APPENDIX B&C CONSTRUCTION TYPE: ENERGY COD 2615 WASHINGTON STATE ENERGY CODE II—B V) LU z (WSEC), WAC 51-11 STANDARD NFPA 13 m o C:) 00 o, MECHANICAL 2015 INTERNATIONAL MECHANICAL CODE (IMC), ZONE: CODE WAC 51-52 C/LI ELECTRICAL 2015 NATIONAL ELECTRICAL CODE (NEC) (NFPA OCCUPANCY: CODE 70) + PART 1 AND PART 3, WASHINGTON B — BUSINESS CITIES ELECTRICAL CODE WITH APPLICABLE RW 19.28 & WAC 296-468 TENANT SQUARE FOOTAGE: PLUMBING 2015 UNIFORM PLUMBING CODE (UPC), WAC (area of work) CODE 51-56 & 51-57 INCL. APPENDIX CHAPTERS H 16,000 SF & L — EXCL. SECTIONS L5—L7 & "LAWN SPRINKLER HEAD" FROM TABLE 6-4 OF LAND AREA APPENDIX L 115,478 SQ. FT. ZONING COD CITY OF TUKWILA 2.65 ACRES ACCESSIBILI 2009 ICC/ANSI Al 17.1 ACCESSIBLE AND CODE USABLE BUILDINGS AND FACILITIES Al Legal uescr tion: TAX PARCEL #: 271600-0060 NE -15-23-4 GATEWAY CORP. CENTER PLATE LOT. 6 VicinityMap: Pr UjVL;L 1111161111a No changes shall be made to the scope of work without prior approval of Ttlkwila Building Division. tl'OT':: Rl-vision5 will require a now plan submittal and may include additional plan review fees. Property Manager: Architect: KIDDER MATHEWS JPC ARCHITECTS, PLLC 12886 INTERURBAN AVE S 909 112TH AVE NE SUITE 206 SEATTLE, WA 98168 BELLEVUE, WA 98004 (206) 248-7328 (425) 641-9200 JIM KIDDER Jkidder@kiddermathews.com Tenant: NORTHWEST HYDRAULICS 12787 GATEWAY DRIVE TUKWILA, WA 98168 (206) 241-6000 TODD BENNETT tbennett@nhcweb.com Construction Manager: FLINN FERGUSON (206) 626-0888 MIKE DUFFY mike@finnferguson.com CHRIS ACKERMAN — EXT. 303 ChrisA@jpcarchitects.com DAN BUTLER — EXT. 326 DanB@jpcarchitects.com General Contractor: FOUSHEE & ASSOCIATES, INC. 3260 118TH AVE. SE BELLEVUE, WA 98004 RECEIV D CITY OF TUIWIL OVER SHEET NW Hydraulics Gateway Corp. Ctr. Bldg 6 1st Floor 12787 Gateway Dr Tukwila, WA 98168 DESIGN JPC DRAWN GB CHECKED CA NO. 16-0427 REGISTERED RCHITECT Z IEL H. BUTLEROF WASHINGTON 7.12.2016 Permit Review Set 7.19.2016 Issue for Permit 0 8.19.2016 Permit Rev 1/CD Set Greg Smalling Owner AECHAM Commercial Plumbing Heating and Gas Piping GS MECHANICAL, LLC New Address: POBox65 Redmond,WA98073-0065 Phone 206 372 0332 greg@gsmechankaishop.com MMN STAMP PLUMBING PLAN LIC. NO: CCFOUSHAC1580D JASON FERLEMAN (425) 746-1000 JFERLEMAN@FOUSHEE.COM SEP 19 PERMIT CEIIITER ml% PLLC 140 0 ry V) LU z m o C:) 00 o, Q s Q � 4 -J N �I NW Hydraulics Gateway Corp. Ctr. Bldg 6 1st Floor 12787 Gateway Dr Tukwila, WA 98168 DESIGN JPC DRAWN GB CHECKED CA NO. 16-0427 REGISTERED RCHITECT Z IEL H. BUTLEROF WASHINGTON 7.12.2016 Permit Review Set 7.19.2016 Issue for Permit 0 8.19.2016 Permit Rev 1/CD Set Greg Smalling Owner AECHAM Commercial Plumbing Heating and Gas Piping GS MECHANICAL, LLC New Address: POBox65 Redmond,WA98073-0065 Phone 206 372 0332 greg@gsmechankaishop.com MMN STAMP PLUMBING PLAN LIC. NO: CCFOUSHAC1580D JASON FERLEMAN (425) 746-1000 JFERLEMAN@FOUSHEE.COM SEP 19 PERMIT CEIIITER ml% PLLC N M CL a �o s Y \ U � Q (n 00 K 2 Oj U E 0 o o0 �--__� __ — — — — =1--- ---. � I II II II II II II IL---------�� —ll IT- � II L II I j 8 TYP. –9 —-----------II----------�--- —SIJ -------------------��--- 5 TYP. [-QTYP. I I I I I I I I I I I I I I I I I I I I I I I I I 0 ✓II II II II II II I � Demolition Plan eq6 ) Scale: 1/8"=l'–O" Key Notes: O NO WORK THIS AREA UNLESS OTHERWISE INDICATED. REFER TO FLOOR PLAN FOR ADDITIONAL INFORMATION. O ROLL–UP, BAG, AND PROTECT EXISTING EXTERIOR WINDOW SHADES. REPAIR AND/OR PROVIDE NEW WHERE FOUND MISSING OR DAMAGED. O DEMOLISH ALL EXISTING FINISH FLOORING AND BASE, UNLESS NOTED OTHERWISE. PATCH AND REPAIR AFFECTED SUBSTRATE AS REQUIRED. FOR INSTALLATION OF NEW FINISH FLOORING AND BASE MATERIALS REFER TO FLOOR AND FINISH PLAN FOR ADDITIONAL INFORMATION. ® DEMOLISH EXISTING PARTITION AND WALLS (PARTIAL, GRID AND FULL HEIGHT) PROTECT EXISTING ADJACENT SURFACES, INCLUDING BUT NOT LIMITED TO CEILING, ADJACENT WALLS AND FLOORING. O SALVAGE ALL REMOVED DOORS FRAMES AND RELITES FOR RE–USE OR RETURN TO BLDG. STOCK, UNLESS DIRECTED OTHERWISE © SALVAGE EXISTING FIRE EXTINGUISHLR/CABINETS FOR RELOCATION. CONTRACTOR TO FIELD VERIFY AND COORDINATE WITH ARCHITECT. O7 DEMOLISH AND DISPOSE OF EXISTING CABINETRY/MILLWORK (UNLESS OTHERWISE NOTE TO BE RETAINED). TERMINATE AND CAP ALL EXISTING SUPPLY/WASTE LINES BEHIND WALL AND/OR FLOOR. PATCH AND REPAIR AFFECTED AREAS, INCLUDING BUT NOT LIMITED TO WALLS, FLOORS, AND CEILINGS AS REQUIRED. ® DEMOLISH ELECTRICAL, LOW VOLTAGE AND LIFE SAFETY DEVICES AS REQUIRED DUE TO DEMOLITION. AT LOCATIONS WHERE ELECTRICAL IS TO BE REMOVED, TERMINATE WIRING AT CLOSEST JUNCTION BOX OR DEMOLISH WIRING BACK TO PANEL. 0 DEMOLISH AND DISPOSE OF EXISTING INSULATION BOARD AND K–FOIL FROM EXISTING OPENING. PREP FOR NEW O.H. GARAGE DOOR INSTALLATION. 10 DEMOLISH AND DISPOSE OF EXISTING EXTERIOR ALUMINUM STOREFRONT WINDOWS. PREP FOR NEW OVERHEAD GARAGE DOOR INSTALLATION. 11 12 13 REMOVE EXISTING MOP SINK AND HOT WATER TANK. SALVAGE FOR REUSE IF POSSIBLE. 14 REMOVE EXISTING TOILET PARTITION DOOR AND PARTIALLY DEMO AND RECONFIGURE TOILET COMPARTMENT STALLS FOR NEW PLAN LAYOUT. SEE FLOOR PLAN. 15 REMOVE PORTION OF EXISTING VINYL TILE FLOOR. REFER TO NEW FLOOR PLAN FOR ADDITIONAL INFORMATION. 1 g REMOVE PORTION OF EXISTING CARPET FLOORING. REFER TO NEW FLOOR PLAN FOR ADDITIONAL INFORMATION. REMOVE EXISTING VINYL FLOORING. REFER TO NEW FLOOR PLAN FOR ADDITIONAL INFORMATION. IPartition Legend: I EXISTING PARTITION/CONSTRUCTION TO REMAIN EXISTING PARTITION TO BE REMOVED EXISTING SHELL & CORE WALLS TO REMAIN REVIEWED FOR CODE COMPLIANCE APPROVED SEP 2 9 2016 Oita' of Tukwila BUILDING DIVISION NW Hydraulics Gateway Corp. Ctr. Bldg 6 1st Floor 12787 Gateway Dr Tukwila, WA 98168 DESIGN JPC DRAWN GB CHECKED CA NO. 16-0427 REGISTERED RCHITECT DANIEL H. BUTLER STATE OF WASHINGTON 7.12.2016 Permit Review Set 7.19.2016 Issue for Permit A 8.19.2016 Permit Rev 1/CD Set Greg Smalling Owner Comrraerciol Plumbing� Heating end Gas Pring GS MECHANICAL, LLC New Address: P08ox65 Redmond.WASS073-0065 Phone 206 372 0331 greg@gsmechanicalshop.com Demolition Plan RECEIVD CITY OF TU ILA SEP 19216 PERMIT CEfER p.1 . © 2016, JPC Architects, PLLC -O O N N Cn w z -I- O C:) 00 Cr_ m Q _ Q N N WMI 01- 0-m NW Hydraulics Gateway Corp. Ctr. Bldg 6 1st Floor 12787 Gateway Dr Tukwila, WA 98168 DESIGN JPC DRAWN GB CHECKED CA NO. 16-0427 REGISTERED RCHITECT DANIEL H. BUTLER STATE OF WASHINGTON 7.12.2016 Permit Review Set 7.19.2016 Issue for Permit A 8.19.2016 Permit Rev 1/CD Set Greg Smalling Owner Comrraerciol Plumbing� Heating end Gas Pring GS MECHANICAL, LLC New Address: P08ox65 Redmond.WASS073-0065 Phone 206 372 0331 greg@gsmechanicalshop.com Demolition Plan RECEIVD CITY OF TU ILA SEP 19216 PERMIT CEfER p.1 . © 2016, JPC Architects, PLLC N U � a o 0- 0- I�1 I i IF —IF -11 EQUIPMENT STORAGE 1 OPEN OFFICE 1 115 117 1 8X8 WS 1 8X8 WS 11 lL LL— HALL HALL 1 jj 1 114 RB -1 113 SYH PRIVATE PRIVATE PRIVATE LOCATION 041) PRIVATE OFFICE OFFICE OFFICE ............. ......... _......... 119 116 118 120 PRIVATE I ..... .. CP P . OFFICE COPY/PRINT FILE /MAIL...............................RB S 113 PRIV TE OFFICE 137 PRIVATE OFFICE 136 -- —— i STORE GE TOOL 12 I JAN. -IT 123 HWT 3/4"CW UT -1 o �- 126 — — — 3/4'HW C I BREA ROOM 1 124 , - - -R ET' PRIVATE PRIVATE OFFICE OFFICE 135 1 134 PL.U'"''« LNG FIXTURE ;BCH MUL. SYH arr MULTIPURPOSE RIDOW:.:.:. LOCATION 041) PRIVATE v .............. ............. ......... _......... 119 OFFICE PRIVATE OFFICE 112 128 I ..... .. CP P . ;: COPY/PRINT FILE /MAIL...............................RB S 2 1 1 . :H Z a � C �1- O O 00 � CONFERENCE.-- CONFER N_ C..E 111 :. . ............................. . * * 107 ....... ..:..:.:..:... .:...:..:. :. :-- -PRIVATE OFFICE Labs t ......._......._.... . ..... . ... ... -..... ..-... - — - - ProAo AFX75pC ,Lead Law Compliant z 2 Eyewash Wall Mounted Lab 8 Tye■rr PRIV TE OFFICE 137 PRIVATE OFFICE 136 -- —— i STORE GE TOOL 12 I JAN. -IT 123 HWT 3/4"CW UT -1 o �- 126 — — — 3/4'HW C I BREA ROOM 1 124 , - - -R ET' PRIVATE PRIVATE OFFICE OFFICE 135 1 134 PL.U'"''« LNG FIXTURE ;BCH MUL. SYH arr 109 LOCATION 041) PRIVATE v .............. ............. ......... _......... ......... .......... ...... _. _......- ...... OFFICE 128 0 -:. . 108...... 1 HB -1 i JARGE-' Z a � C �1- O O 00 � CONFERENCE.-- CONFER N_ C..E ----n' --- - ------ ..... .. .......... 107 ....... ..:..:.:..:... .:...:..:. :. :-- Hose Bib Labs t ......._......._.... .E.... PRIVATE ProAo AFX75pC ,Lead Law Compliant z 2 Eyewash Wall Mounted Lab 20 Tye■rr OFFICE Fixture: Furnished by owner OT -2 2 OtIIItYTub 106 20 a 1/2.. 212" Fixture- Mustee 17F OtIlaTub HALL 104 I SH -1 2 Shower Shower-R-pom 20 3120 P.::: PRIVATE OFFICE PRIVATE HWT--1 T Water Heater 2 103 OFFICE S40 mfr Fixture- 40 Smith ECT -50 105 PRIV TE OFFICE 137 PRIVATE OFFICE 136 -- —— i STORE GE TOOL 12 I JAN. -IT 123 HWT 3/4"CW UT -1 o �- 126 — — — 3/4'HW C I BREA ROOM 1 124 , - - -R ET' PRIVATE PRIVATE OFFICE OFFICE 135 1 134 PL.U'"''« LNG FIXTURE ;BCH MUL. SYH arr fqxTUFM LOCATION 041) W v CW 144 SPMCIRCATION + 128 0 C UT -1 NO O N N 1 HB -1 i Z a � C �1- O O 00 � N s HB -2 2 Hose Bib Labs m ProAo AFX75pC ,Lead Law Compliant EW -2 2 Eyewash Wall Mounted Lab 20 Tye■rr (E) 1-1/2" CW Fixture: Furnished by owner OT -2 2 OtIIItYTub Labitor 20 Tye„ 1/2.. 212" Fixture- Mustee 17F OtIlaTub LAB I SH -1 2 Shower Shower-R-pom 20 3120 45■ V2 Fixture- Fiber -Fab 98-1 CAE)A) wl pelta T -),H2000 shower valve 4- slide rail HWT--1 T Water Heater Janitor S40 mfr Fixture- 40 Smith ECT -50 r-x—x—x—x—x—x—x—x—x—x—x- X �x f ENCLQIIOURE I i I I EW -1 AREA OF WORK 128 0 C UT -1 NO O N N 1 HB -1 i Z a � C �1- O O 00 � N s 1 1"CW 6 m 6 m EXIST. 1 WOMEN'S (E) 1-1/2" CW - � -----4------ - - - - - -- ----- - - - - -- --- -�---- LAB I 140 �3/4"CW — { HB -1 SERVER )RAGE. LI f��RY 129 PLOTTER/ LIBRARY 130 PRIVATE OFFICE 131 PRIVATE OFFICE 132 PRIVATE OFFICE 133 1/2"U'T = 1r2` EC+1-1 HB -1 1 EXPANSION TANK ON INLET SIDE. PLUMBIr SCALE: NOT TO SCALE 1,2" £1T-1 Zlf4-1f r GL F;xci 1/2" HB -1 I✓ u Enlarged Restroom Plan scale: 4'-0' FOLDING OR FIXED SEATS _ L"I�II'all �d"r,1:I7a: NOTE: HAND-HELD SHOWERS ARE REQUIRED IN ACCESSIBLE SHOWERS. IB` VERTICAL GRAB BAR 4' VAX FROM SHOWER ENTRY (SEE ELEVATION) NOTE: VMEN EQUIPPED WITH A FOLDING SEAT, THE TRANSFER SHOWER COMPARTNENr MAY HAVE A THRESHOLD 2' ►tAX WHERE EXISTING CONDMONS WILL NOT ALLOW ALTERATIONS INTO A STRUCTURAL SLAB. Enlarged Shower Plan CONTROLS SHALL BE LOCATED WITHIN 15' LEFT OR RIGHT OF CENLERUNE OF THE SEAT PER ICC A117 SECTION 608.5.1. m I J cc Lail LaM i ='idn � Ln -r � {�gipp UQ NOTE: MUD -HELD SHOWERS ARE REQUIRED IN ACCESSIOLE SHOWERS. BUILDING STANDARD ADA GRAB BARS �-11,151 4T" Pw PER coin HWT-1 PIPING DIAGRAM I I I N.T.S. - 4 N V.T.R. PLUMBING WASTE & VEN RISER FOR \ ` 'CQa�PPRaVEIaNCE II I 1 wco 2`y SEP 2 9 2016 [V + n I �4sq we BS \ From cel Cit' Of Tukwfa WCO 2" Restrooms `II `+v BUILDING D(WSIO 2" EW -1 2" OT -1 II 41f (JT -2 / - sH 1 I I r 4b i i la's x 1!2 SAN WCO 2" SH 1 3" Connect at existing Floor clean out orYj Pstrooms. Field verIFY V) NO O N N to W Z a � C �1- O O 00 � N s N 6 m 6 m Gateway Corp. Ctr. Bldg 6 1 st Floor 12787 Gateway Dr Tukwila, WA 98168 DESIGN JPC DRAWN GB CHECKED CA NO. 16-0427 REGISTERED RCHITECT DANIEL H. BUTLER STATE OF WASHINGTON 7.12.2016 Permit Review Set 7.19.2016 Issue for Permit Qi 8.19.2016 Permit Rev 1/CD Set Greg Smalling Owner ECHANICAL Commercial Plumbing, Heating and Gas Piping GS MECHANICAL, LLC New Address: P0E3ox65 Redmond,WA99073-0065 Phone 206 372 0332 rreilia'%¢sm ech aniG0lshob.COn1 PLUMBING FLOOR PLAN RECEIVED �ITY OF TUKWILA SEP 19 2016 PERMIT CENf?P,1 .2 © 2016, JPC Architects, PLLC