Loading...
HomeMy WebLinkAboutPermit PG16-0144 - BOEING EMPLOYEES CREDIT UNION (BECU) - SINKS, DISHWASHER, WATER HEATER AND FLOOR DRAINSBECU 12770 GATEWAY DR PG16-0144 City of Tukwila • Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 " Phone: 206-431-3670 Inspection Request Line: 206-438-9350 Web site: http://www.TukwilaWA.gov PLUMBING/GAS PIPING PERMIT Parcel No: 2716000075 Permit Number: PG16-0144 Address: 12770 GATEWAY DR Issue Date: 11/16/2016 Permit Expires On: 5/15/2017 Project Name: BECU Owner: Name: BOEING EMPLOYEES CREDIT UNI Address: PO BOX 97050, SEATTLE, WA, 98124 Contact Person: 2015 Name: KAYLENE NELSON Address: 1221 SECOND AVE N, KENT, WA, WA Cities Electrical Code: 98032 Contractor: 2015 Name: HERMANSON COMPANY LLP Address: 1221 2ND AVE N, KENT, WA, 98032- 2945 License No: HERMACLO05BJ Lender: Name: Address: , , , DESCRIPTION OF WORK: Phone: (253) 359-7147 Phone: (206) 575-9700 Expiration Date: 8/25/2018 PROVIDE AND INSTALL (1) HAND SINK, (1) KITCHEN SINK, (1) DISHWASHER, (1) WATER HEATER AND (3) FLOOR DRAINS ALL WORK IS INSIDE THE DETACHED COFFEE KIOSK AND INCLUDES INSTALLATION OF BIG DIPPER GREASE REMOVAL SYSTEM AND 2 REDUCED PRESSURE PRINCIPLE ASSEMBLIESLIES (RPPAs) INSIDE THE CABINET FOR THE EXPRESSO AND ICEMAKER MACHINE. Valuation of Work: $28,341.00 Fees Collected: $235.96 Water District: TUKWILA Sewer District: TUKWILA Current Codes adopted by the City of Tukwila: International Building Code Edition: 2015 National Electrical Code: 2014 International Residential Code Edition: 2015 WA Cities Electrical Code: 2014 International Mechanical Code Edition: 2015 WAC 296-4613: 2014 Uniform Plumbing Code Edition: 2015 WA State Energy Code: 2015 International Fuel Gas Code: 2015 Permit Center Authorized Signature: Date: I hearby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this development per�rait�aryl agree to the conditions attached to this permit. Signature: l Print Name: Date: I b ub- This permit shall become null and void if the work is not commenced within 180 days for the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. PERMIT CONDITIONS: 1: BIG DIPPER Grease Removal system shall be installed and maintained per manufacturer's specifications. RPPA requires a separate Public Woks inspection, please call 206 433-0179 to schedule a backflow inspection. Backflows shall be installed per manufacturer's specifications and tested by a certified tester. Passing test reports shall be submitted to the Public Works Inspectors. Drainage shall be provided for both RPBPs installed inside the cabinet. Thereafter the RPBPs shall be tested annually and the owner's expense and backflow test results shall be submitted to Tukwila Water Dept., 600 Minkler Blvd, Tukwila, WA 98188, phone: 206 433-1860, fax: 206 571-3404. 3: ***PLUMBING/GAS PIPING PERMIT CONDITIONS*** 4: No changes shall be made to applicable plans and specifications unless prior approval is obtained from the Tukwila Building Division. 5: All permits, inspection records and applicable plans shall be maintained at the job and available to the plumbing inspector. 6: All plumbing and gas piping systems shall be installed in compliance with the Uniform Plumbing Code and the Fuel Gas Code. 7: No portion of any plumbing system or gas piping shall be concealed until inspected and approved. 8: All plumbing and gas piping systems shall be tested and approved as required by the Plumbing Code and Fuel Gas Code. Tests shall be conducted in the presence of the Plumbing Inspector. It shall be the duty of the holder of the permit to make sure that the work will stand the test prescribed before giving notification that the work is ready for inspection. 9: No water, soil, or waste pipe shall be installed or permitted outside of a building or in an exterior wall unless, adequate provision is made to protect such pipe from freezing. All hot and cold water pipes installed outside the conditioned space shall be insulated to minimum R-3. 10: Plastic and copper piping running through framing members to within one (1) inch of the exposed framing shall be protected by steel nail plates not less than 18 guage. 11: Piping through concrete or masonry walls shall not be subject to any load from building construction. No plumbing piping shall be directly embedded in concrete or masonry. 12: All pipes penetrating floor/ceiling assemblies and fire -resistance rated walls or partitions shall be protected in accordance with the requirements of the building code. 13: Piping in the ground shall be laid on a firm bed for its entire length. Trenches shall be backfilled in thin layers to twelve inches above the top of the piping with clean earth, which shall not contain stones, boulders, cinderfill, frozen earth, or construction debris. 14: The issuance of a permit or approval of plans and specifications shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the Plumbing Code or Fuel Gas Code or any other ordinance of the jurisdiction. 15: The applicant agrees that he or she will hire a licensed plumber to perform the work outlined in this permit. 16: All new plumbing fixtures installed in new construction and all remodeling involving replacement of plumbing fixtures in all residential, hotel, motel, school, industrial, commercial use or other occupancies that use significant quantities of water shall comply with Washington States Water Efficiency ad Conservation Standards in accordance with RCW 19.27.170 and the 2006 Uniform Plumbing Code Section 402 of Washington State Amendments PERMIT INSPECTIONS REQUIRED Permit Inspection Line: (206) 438-9350 8004 GROUNDWORK 1900 PLUMBING FINAL 8005 ROUGH -IN PLUMBING CITY OF TUKWIL Community Development Department Permit Center • 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 " hllp://www.TukwilaWA.gov Plumbing/Gas Permit No. Project No. ll Date Application Accepted: Date Application Expires: or office use only) PLUMBING / GAS PIPING PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. "Please Print" SITE LOCATION King Co Assessor's Tax No.: 2716000075 Site Address: 12770 Gateway Dr Tukwila, WA 98168 Suite Number: Cafe Floor: 1 Tenant Name: BECU New Tenant: ❑ .....Yes E].. No PROPERTY OWNER Name: Boeing Employees Credit Union Address: 327 Tukwila Parkway City: Tukwila State: WA Zip: 98188 CONTACT PERSON — person receiving all project communication Name: Kaylene Nelson Address: 1221 2nd Avenue N City: Kent State: WA Zip: 98032 Phone: (253) 359-7147 Fax: Email: Kaylene.nelson@hermanson.com Valuation of Project (contractor's bid price): $ 28,341 Scope of Work (please provide detailed information): PLUMBING CONTRACTOR INFORMATION Company Name: Hermanson Company Address: 1221 2nd Avenue N City: Kent State: WA Zip: 98032 Phone: (253) 359-7147 Fax: Contr Reg No.: HERMACL005BJ Exp Date: 08/25/2018 Tukwila Business License No.: BUS -0994464 Provide and install (1) Hand sink, (1) Kitchen sink, (1) Dishwasher, (1) Hot water tank and (3) Floor Drains Building Use (per Int'l Building Code): Occupancy (per int'l Building Code): Utility Purveyor: Water: Sewer: H: Applications\Forms-Applications On Line�201 I Applications\Plumbing Permit Application Revised 8-9-1 I.docs Revised: August 2011 Page 1 of 2 bh Indicate type of plumbing fixtures and/or gu. piping outlets being installed and the quantity uelow: Fixture Type Qty Bathtub or combination bath/shower 3 Dishwasher, domestic with 1 independent drain Shower, single head trap Sinks 2 Rain water system — per drain (inside building) Grease interceptor for commercial kitchen (>750 gallon capacity) Each additional medical gas inlets/outlets greater than 5 Atmospheric -type vacuum breakers not included in lawn sprinkler backflow protections 1-5) Fixture Type Qty Bidet Drinking fountain or water 3 cooler (per head) Lavatory Urinal Water heater and/or vent Repair or alteration of water piping and/or water treatment equipment Backflow protective device other than atmospheric - type vacuum breakers 2 inch (51 mm) diameter or smaller Atmospheric -type vacuum breakers not included in lawn sprinkler backflow protections over 5 PERMIT APPLICATION NOTES - Fixture Type Qty Clothes washer, domestic 3 Food -waste grinder, commercial Wash fountain Water closet Industrial waste treatment interceptor, including trap and vent, except for kitchen type ease interceptors Repair or alteration of drainage or vent piping Backflow protective device other than atmospheric -type vacuum breakers over 2 inch (51 mm) diameter Gas piping outlets Fixture Type Qty Dental unit, cuspidor Floor drain 3 Receptor, indirect waste Building sewer and each trailer park sewer Each grease trap (connected to not more than 4 fixtures - <750 gallon capacity Medical gas piping system serving 1-5 inlets/outlets for a specific as Each lawn sprinkler system on any one meter including backflow protection devices Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation The Building Official may grant one extension of time for an additional period not to exceed 180 days. The extension shall be requested in writing and justifiable cause demonstrated. Section 103.4.3 International Plumbing Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING Signature: Print Name: Kaylene Nels I Mailing Address: 1221 2n venue N HrApplications%Forms-Applications On Line`201 I Applications�Plumbing Permit Application Revised 8-9-1 I.docx Revised: August 2011 bh Date: 09/23/2016 Day Telephone: (253) 359-7147 Kent WA 98032 City State Zip Page 2 of 2 DESCRIPTIONS ACCOUNT QUANTITY PAID PermitTRAK $457.28 M16-0149 Address: 12770 GATEWAY DR Apn: 2716000075 $221.32 MECHANICAL $212.81 PERMIT ISSUANCE BASE FEE R000.322.100.00.00 0.00 $32.50 PERMIT FEE R000.322.100.00.00 0.00 $137.75 PLAN CHECK FEE R000.322.102.00.00 0.00 $42.56 TECHNOLOGY FEE $8.51 TECHNOLOGY FEE R000.322.900.04.00 0.00 $8.51 PG16-0144 Address: 12770 GATEWAY DR Apn: 2716000075 $235.96 PLUMBING $226.88 PERMIT ISSUANCE BASE FEE R000.322.100.00.00 0.00 $32.50 PERMIT FEE R000.322.100.00.00 0.00 $149.00 PLAN CHECK FEE R000.322.103.00.00 0.00 $45.38 TECHNOLOGY FEE $9.08 TECHNOLOGY FEE TOTAL FEES PAID BY RECEIPT: R9481 R000.322.900.04.00 0.00 $9.08 $457.28 Date Paid: Friday, September 23, 2016 Paid By: KAYLENE NELSON Pay Method: CREDIT CARD 301650 Printed: Friday, September 23, 2016 10:47 AM 1 of 1 SY57EM5 INSPECTION RECORD l Retain a copy with permit ��`�'/ INSPECTION NO. PERMIT N0. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., 4100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request line (206) 438-9350 Project: .BCV Type of Inspection: inl`IAL pLIL)IMB lelG Address: 127 70 6,ft u A W Date Called: Special Instructions: Date Wanted:a.m — &—i7 p.m. Requester: Phone No: (Inspector: 9< IDate: ;'-1 / —/ REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. INSPECTION RECORD I" Retain a copy with permit [P& 6- 0/ q# INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Project- Scc o T of Inspection: )51:641 - Address: 1277© Ne Date Called: Special Instructions: Date Wanted 3 1 a. p.m. Requester.. Phone No: ❑ Approved per applicable codes. " Corrections required prior to approval. COMMENTS: PlOg/,rC A--'0 A<S 11Y57PZ-c770H A jrQ V/ RjC I fAt0lN Tra ALP R/4/6- /z-/M/f e-- I Inspector: Date: EJ REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. INSPECTION RECORD 1 0 Retain a copy with permit �6 -01'gL1 INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Project: Type of Inspection' Ct1 e Address: Date Called: ?U VZ Special Instructions: rR—equate Wante m. 2 / 7 . este :: I Phone No: ZEA - ❑ Approved per applicable codes. 5�1 Corrections required prior to approval. W. I yPv,&-1e W®.4�5' I Inspector: Date: 3—L ;2 —/% REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. INSPECTION RECORD Retain a copy with permit lwL�- 0�u�1 INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Praje��� `� T�e of Inspection: - l' pU rn P, 1 Address: EZ?7& Date Called: Special Instructions: Date Wanted: a. 2 00 % p. Requester: Phone No: u Approved per applicable codes. 0 Corrections required prior to approval. Ilnspector: Z", (DateI //C REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. INSPECTION RECORD Retain a copy with permit�� IN CTION N0. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Project: Z�,C Type of Inspection: 1�(,�J-gj/ Address: 1? -720 6g6,kw"brz Date Called: Special Instructions: Date Wanted* I Z /6 i Requester: Phone No: 5-S—' %%77 MApproved per applicable codes. 1:1 Corrections required prior to approval. Inspector &dd4 Date: i Z / 166 REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. B10 ® 01 Technology Big Dipper"' IS Point Source Automatic Grease Removal Systems *+*W -200 -IS Specifications PRODUCT FEATURES • Fully automatic self cleaning cycle. Actively removes collected grease & oils from tank without any operator assistance. Comes complete with Digital Control and Grease Collector. • Constructed of corrosion resistant materials suitable for installation in virtually any location. Attractive sanitary Stainless Steel exterior. • Integrated Motor/Grease Outlet/Heater/Lid enables a fast, do-it-yourself unit operation reversal. • Compact footprint. • Two (2) No -Hub Connectors provided. SPECIFICATIONS I" I am= END VIEW Construction: Exterior: 304 Stainless Steel, Bright Finish Interior: Rotationally Molded Polyethylene Electrical: 115 VAC, 50/60 Hz, 520 Watts (4.5 Amps)* Flow Rating: 20 GPM (1.26 I/s) Oil Retention Capacity: 22.7 gallons (85.9 1) No. of Skimming Wheels: 1 Grease Retention Capacity: 40+ Pounds (18.14 Kg) Internal Solids Strainer Capacity: _ 1.85 Gallons (7 Liters) Inlet/Outlet: 2" (50 mm) For Additional Electrical Configurations, see Electrical Variations section on page 2. RECEIVED OCT 10 2016 TUKWILA SIDE VIEW PUBLIC WORKS 24.25" 1616 mm) CLEARANCE FROM BOTTOM OF TANK REQUIRED FOR STRAINER BASKET & LID REMOVAL 14.00 in 355.6 mm GC -7 15.50 in INL GREASE 393.7 mm in COLLECTOR OUTLET 8 QUART (7.6 L) MITI 6.00 in CAPACITY 6.00 in 152.4 mm 152.4 mm MOTOR/DIGITAL CONTROL ENCLOSURE 23.38 in 593.7 mm 10.25 in 260.4 (EO mm) PIPE INLET/OUTLET 8.80 in 223.5 mm TOP VIEW INLET OUTLET TUKWIL 17.50 in 444.5 mm REVIEWED F i % 25.50 in -� 7 2016 :ODE COMPLIANCE 647.7 mm 28.50 in APPROVED 'MY}11T CENTER NOV 0 2 20160 R RF_ TON � ICC �-� T R # CER[1P IEO G S UPC 4s City of Tukwila m ✓® o us Q tic BUILDING QJVISIOIN Cart toASMESM.dlN ASME A112.1<.3 And A112.1C.< ©2016 Thermaco, Inc. • All rights reserved • Patented/Patents Pending • Specificatio su t to Thermaco, Inc. • PO Box 2548 • Asheboro, NC 27204-2548 • (336) 629-46 BIC0/ R® A THERMACO® Technology 4 in 101.6 mm 17.85 in 453.4 mm 5.7: 145 4.0( 101 6.00 in 152.4 mm INLET 6.00 in 152.4 mm OUTLET Big Dipper® IS Point Source Automatic Grease Removal Svstems W -200 -IS Specifications JOB SPECIFICATION INSTALLATION NOTES 1. READ instruction manual included with system before installing/operating. 2. Install unit allowing for the minimum clearances shown. Make sure there issuff icient space above Internal Strainer access cover to remove the strainer [minimum of 14" (356mm)] 3. Make piping connections with rubber "No Hub" con- nectors. 4. Keep outlet piping as straight as possible. Use only "sweep" connections. 5. Install vent on outlet piping. 6. Fill the tank with water before energizing the power to the motor and heater. 7. Do not install "P" Trap on outlet connection of tank (unit already has internal gas trap). 8. Do not reduce pipe size on outlet piping 9. Do not pressure test unit. Equipment must be installed in compliance with all ap- plicable laws, regulations and codes, including plumbing codes. Installation should be performed by a qualified plumbing contractor. Grease and oils separator(s) shall be Thermaco Big Dipper automatic grease/oil recovery system(s) as manufactured by Ther- maco, Inc., Asheboro, North Carolina as noted on plans. I Furnish and install _ Therma6o Big Dipper Model No. W -200 -IS, bright finish type 304 stainless steel exterior, rotationally molded polyethylene interior automatic self-cleaning grease and oil recovery separator(s) for floor mounted or partially recessed installation, rated at 20 gallons per minute (1.26 liters per second) peak flow, 40 pounds (18.14 Kg) of grease capacity and in- cluding as an integral part of the unit, 1 rotating gear hydrophobic wheel assembly for automatic grease/oil removal, an integral flow control device, self-regulating enclosed electric immersion heater, a vessel vent, an integral gas trap, a digital control for programmable operation, a field reversible motor location, a field reversible grease/oil sump outlet, quick release stainless steel lid clamps, a gasketted and fully removable 304 stainless steel lid, a lift -out strainer basket access, an internal stainless steel strainer basket for collection of coarse solids, and a separate grease and oils collection container. Electric assembly shall be tested to comply with pertinent sections of the Standards for Safety ANSI/UL 73 and/or ANSI/UL 1004. Electric motor equipped with overload protection. Two (2) no -hub connectors for plumbing connection provided. 115V 50/60Hz, 520 Watts (4.5 Amps) ❑ W -200 -IS -E: 230V 50/60Hz, 520 Watts (2.3 Amps) SUBMITTAL OPTIONS ❑ FS -1 Point Source Flat Strainer ❑ ESU -1 External Strainer (1.16Gallons of additional solids storage capacity) ❑ AP -6000 -1 -TK Alarm Probe for excessive grease accumulation El AP -6000-1 -TKDC Alarm Probe with dry contact for remote warning light notification ❑ HAG -2 Horizontal Air Gap Assembly with 2" connection I ❑ HAG -BA -1 Solids Strainer Baskets for use with HAG -2 Assembly (Specify Quantity based on Number of Sinks: _) ©2016 Thermaco, Inc. • All rights reserved - Patented/Patents Pending - Specifications subject to change without notice Thermaco, Inc. • PO Box 2548 • Asheboro, NC 27204-2548 • (336) 629-4651 - www.big-dipper.com Job Name Job Location Engineer For Health Hazard Applications Contractor Approval Contractor's P.O. No. Approval Representative Series LF009 Reduced Pressure Zone Assemblies Sizes: 1/4" - 3" (8 - 80mm) Series LF009 Reduced Pressure Zone Assemblies are designed to protect potable water supplies in accordance with national plumbing codes and water authority requirements. This series can be used in a variety of installations, including the prevention of health hazard cross - connections in piping systems or for containment at the service line entrance.The LF009 features Lead Free* construction to comply with Lead Free* installation requirements. This series features two in-line, independent check valves, captured springs and replaceable check seats with an intermediate relief valve. Its compact modular design facilitates easy maintenance and assem- bly access. Sizes 114" - 1" (8 - 25mm) shutoffs have tee handles. Features • Single access cover and modular check construction for ease of maintenance • Top entry - all internals immediately accessible • Captured springs for safe maintenance • Internal relief valve for reduced installation clearances • Replaceable seats for economical repair • Lead Free* cast copper silicon alloy body construction for durability 1/4" - 2" (8 - 50mm) • Fused epoxy coated cast iron body 21/2" and 3" (65 and 80mm) • Ball valve test cocks - screwdriver slotted 1/4" - 2" (8 - 50mm) • Large body passages provides low pressure drop • Compact, space saving design • No special tools required for servicing Specifications A Reduced Pressure Zone Assembly shall be installed at each potential health hazard location to prevent backflow due to backsiphonage and/ or backpressure. The assembly shall consist of an internal pressure differential relief valve located in a zone between two positive seating check modules with captured springs and silicone seat discs. Seats and seat discs shall be replaceable in both check modules and the relief valve. There shall be no threads or screws in the waterway exposed to line fluids. Service of all internal components shall be through a single access cover secured with stainless steel bolts. Body and shutoffs shall be constructed using Lead Free' cast copper silicon alloy materials. Lead Free* reduced pressure zone assembly shall comply with state codes and standards, where applicable, requiring reduced lead con- tent. LF009 Test Cock No. 3 Ball Type Test Cocks Test Cock First Check r. wy- Module t� Assembly r • R.P. Zone -t"f Relief Valve Assembly est Cock No. 4 Second Check Module Assembly Water Outlet Now Available WattsBox Insulated Enclosures. For more information, send for literature ES -WB. Inquire with governing authorities for local installation requirements The assembly shall also include two resilient seated isolation valves, four resilient seated test cocks and an air gap drain fitting. The assem- bly shall meet the requirements of: USC; ASSE Std. 1013; AWWA Std. *The wetted surface of this product contacted by consumable C511; CSA B64.4. Shall be a Watts Series LF009. water contains less than 0.25% of lead by weight. Watts product specifications in U.S. customary units and metric are approximate and are provided for reference only. For precise measurements, w XXIWATM please contact Watts Technical Service. Watts reserves the right to change or modify product design, construction, specifications, or materials with- out prior notice and without incurring any obligation to make such changes and modifications on Watts products previously or subsequently sold. Available Models: 1/4" - 2" (8 - 50mm) 'Suffix: 1VrQT - quarter -turn ball valves S - strainer LF - without shutoff valves PC - internal polymer coating Prefix: for 909, 009 and 993 sizes U - union connections Available Models: 2'/2" - 3" (65 - 80mm) Suffix: NRS - non -rising stem resilient seated gate valves OSY - UUFM outside stem and yoke resilient seated gate valves S -FDA - FDA epoxy coated strainer QT -FDA - FDA epoxy coated quarter -turn ball valves LF - without shutoff valves Note: The installation of a drain line is recommended. When install- ing a drain line, an air gap is necessary (see ES -AG). Materials: 1/4" - 2" (8 - 50mm) Lead Free' cast copper silicon alloy body construction, silicone rubber disc material in the first and second check plus the relief valve. Replaceable polymer check seats for first and second checks. Removable stainless steel relief valve seat. Stainless steel cover bolts. Standardly furnished with NPT body connections. Model LF009QT furnished with quarter -turn, full port, resilient seated, Lead Free' cast copper silicon alloy body ball valve shutoffs. Materials: 2'/2" and 3" (65 - 80mm) • (FDA approved) Epoxy coated cast iron unibody with plastic seats • Relief valve with stainless steel seat and trim • Lead Free cast copper silicon alloy body ball valve test cocks Air Gaps and Elbows Pressure / Temperature Sizes 1/4" - 2" (8 - 50mm) Suitable for supply pressure up to 175psi (12 bar). Water temperature: 33°F - 180°F (0.5° - 75°C). Sizes 21/2" and 3" (65 and 80mm) are suitable for supply pressures up to 175psi (12.1 bar) and water temperature at 110°F (43°C) continuous, 140°F (60°C) intermittent. Standards USC ASSE No. 1013 AWWA C511 CSA B64.4 IAPMO File No. 1563. esu u� SPS uP`® Approvals ASSE, AWWA, CSA, IAPMO Approved by the Foundation for Cross -Connection Control and Hydraulic Research at the University of Southern California. Approval models QT, PC, NRS, OSY. UL Classified 2112" and 3" (65 and 80mm) with OSY gate valves. 3/4" - 2" (20-50mm) without shutoff valves (-LF) (except LF009M3LF) MODEL DRAIN OUTLET DIMENSIONS WEIGHT for 909, 009 and 993 sizes A B in. mm in. mm in. mm lbs. kgs. 909AGA/4"-'/i' 009, 'h 13 2% 60 3'/e 79 0.625 0.28 3/" 009M2/M3 909AGC 3/"-1" 009/909, 1 25 T/4 83 4% 124 1.5 0.68 1 "-1'h" 0091V2 909AGF 1'/4"-2" 0091V1, 2 51 4% 111 63/4 171 3.25 1.47 1114"-3" 009/909, 2" 009M2 4"-6" 993 909AGK 4"-6" 909, 3 76 6% 162 9% 244 6.25 2.83 8"-10" 909M1 909AGM 8"-10" 909 4 102 7% 187 11'/4 286 15.5 7.03 909ELAb"-'/z" 009,'/4" 009M2/M3 - - - - - - - - 909ELC %11-111009/909 - - 2% 60 2% 60 0.38 0.17 • 909ELF 1'/4"-2" 0091V1, - - 3% 92 3% 92 2 0.91 1'/4"-2" 009/909, 2" 009M2 4"4" 993 • 909ELH 2'/z"-3" 009/909 - - - - - - - - Vertical k �r Dimensions and Weight: 1/4" - 2" (8 - 50mm) LF009 LF009'/4" - 2" Dimensions and Weight: 21/2" and 3" (65 and 80mm) LF009 Ni N STRAINER SIZE DIMENSIONS M N Nit in. mm in. mm in. mm in. mm lbs. kgs. 2'/2 65 10 254 6'/2 165 93/4 248 28 12.7 3 80 10Ys 257 7 178 10 254 34 15.4 tClearance for servicing )en Watts G-4000 Series QT - Ball Valves Capacity Performance as established by an independent testing laboratory. kPa psi ''/a" (8mm) LF009QT 138 20 117 17 96 14 76 11 55 8 35 5 �P 0 .25 .60 .75 1 1.17 gpm 0 .95 1.9 2.9 3.8 4.5 Ipm kPa psi 3/8" (10mm) LF0090T 138 20 117 17 96 14 76 11 55 8 35 5 0 .25 50 .75 1 1.25 1.50 2.5 3.1 gpm AP 0 .95 1.9 2.9 3.8 4.8 5.7 9.4 11.8 Ipm kPa psi � 2- (15mm) LF0090T 172 25 138 20 103 15 69 10 35 5 0 1 2.5 5 7.5 10 12.5 15 gpm AP 0 3.8 9.5 19 28.5 38 47.5 57 Ipm 5 7.5 15 fps 1.5 2.3 4.6 mps kPa psi 207 30 165 24 124 18 83 12 41 6 0 0 3/4" (20mm) LF009M30T 0 2 6 10 14 18 22 26 30 34 38 42 46 gpm AP 07.6 23 38 53 68 84 99 114 129 144 160175 Ipm 7.5 15 fps 2.3 4.6 mps kPa psi 1" (25mm) LF009M20T 207 30 172 25 138 20 103 15 69 10 35 5 0 0 0 5 10 20 30 40 50 60 70 80 gpm AP 0 19 38 76 114 152 190 228 266 304 Ipm 7.5 15 fps 2.3 4.6 mps IMWArM A Watts Water Technologies Company 'Typical maximum system flow rate (7.5 feet/sec., 2.3 meters/sec.) kPa psi 111" (32mm) LF009M2QT 172 25 138 20 103 15 69 10 35 5 0 0 �P 0 10 20 30 40 50 60 70 80 0 38 76 114 152 190 228 266 304 5 7.5 10 15 1.5 2.3 3.0 4.6 kPa psi 1'/2" (40mm) LF009M20T 207 30 172 25 138 20 103 15 69 10 35 5 0 0 0 10 20 30 40 50 60 70 80 90 100 110120 AP 0 38 76 114 152 190 228 266 304 342 380 418 456 5 7.5 10 15 1.5 2.3 3.0 4.6 kPa 207 172 138 103 69 35 0 kPa 172 138 103 69 35 0 psi 2" Imm) LF009M20T APO20 40 60 80 100 120 140 160 180 200 0 76 152 228 304 380 456 532 608 684 760 10 5 7.5 10 5 15 0 0 1.5 2.3 3.0 4.6 25 50 75 100 125 150 175 200 225 250 275 300 325 psi 25 2112" (65mm) LF009 95 190 285 380 475 570 665 760 855 950 104511401235 Ipm 20 5 7.5 10 fps 1.5 2.3 3.0 mps 15 t0 5 0 0 25 AP 0 05 50 75 10- 295 100 125 150 380 475 570 175 665 200 760 225 250 885 950 5 7.5 10 15 1.5 2.3 3.0 4.6 Ippm fps mps gpm Ipm fps mps gpm Ipm fps mps Ippm fps mps kPa 172 psi 25 3" (80mm) LF009 138 20 103 15 69 10 35 5 0 0 �P 0 25 50 75 100 125 150 175 200 225 250 275 300 325 gpm 0 95 190 285 380 475 570 665 760 855 950 104511401235 Ipm 5 7.5 10 fps 1.5 2.3 3.0 mps USA: Tel: (978) 688-1811 • Fax: (978) 794-1848 • www.watts.com Canada: Tel: (905) 332-4090 • Fax: (905) 332-7068 • wwwmatts.ca ES-LF009 1318 © 2013 Watts For Health Hazard Applications Job Name - Job Location Engineer — Approval — Series LF009 Reduced Pressure Zone Assemblies Sizes: 1/4" - 3" (8 - 80mm) Series LF009 Reduced Pressure Zone Assemblies are designed to protect potable water supplies in accordance with national plumbing codes and water authority requirements. This series can be used in a variety of installations, including the prevention of health hazard cross - connections in piping systems or for containment at the service line entrance.The LF009 features Lead Free' construction to comply with Lead Free" installation requirements. This series features two in-line, independent check valves, captured springs and replaceable check seats with an intermediate relief valve. Its compact modular design facilitates easy maintenance and assem- bly access. Sizes 1/4" - 1 " (8 - 25mm) shutoffs have tee handles. Features • Single access cover and modular check construction for ease of maintenance • Top entry - all internals immediately accessible • Captured springs for safe maintenance • Internal relief valve for reduced installation clearances • Replaceable seats for economical repair • Lead Free` cast copper silicon alloy body construction for durability 1/4" - 2" (8 - 50mm) • Fused epoxy coated cast iron body 21/2" and 3" (65 and 80mm) • Ball valve test cocks — screwdriver slotted 'A" - 2" (8 - 50mm) • Large body passages provides low pressure drop • Compact, space saving design • No special tools required for servicing Specifications A Reduced Pressure Zone Assembly shall be installed at each potential health hazard location to prevent backflow due to backsiphonage and/ or backpressure. The assembly shall consist of an internal pressure differential relief valve located in a zone between two positive seating check modules with captured springs and silicone seat discs. Seats and seat discs shall be replaceable in both check modules and the relief valve. There shall be no threads or screws in the waterway exposed to line fluids. Service of all internal components shall be through a single access cover secured with stainless steel bolts. Body and shutoffs shall be constructed using Lead Free` cast copper silicon alloy materials. Lead Free' reduced pressure zone assembly shall comply with state codes and standards, where applicable, requiring reduced lead con- tent. The assembly shall also include two resilient seated isolation valves, four resilient seated test cocks and an air gap drain fitting. The assem- bly shall meet the requirements of: USC; ASSE Std. 1013; AWWA Std, C511; CSA B64.4. Shall be a Watts Series LF009. Contractor Approval Contractor's P.O. No. Representative r LF009 Test Cock No. 3 Ball Type Test Cocks Test Cock r First Check - s Module Assemblv l � i { R.P. Zone t �{ Relief Valve Assembly l Test Cock No. 4 Second Check \'\ Module Assembly Water Outlet Now Available WattsBox Insulated Enclosures. For more information, send for literature ES -WB. Inquire with governing authorities for local installation requirements 'The wetted surface of this product contacted by consumable water contains less than 0.25% of lead by weight. Watts product specifications in U.S. customary units and metric are approximate and are provided for reference only. For precise measurements, ����® please contact Watts Technical Service. Watts reserves the right to change or modify product design, const ucdon, specifications, or materials with- out prior notice and without incurring any obligation to make such changes and modifications on Watts products previously or subsequently sold. Available Models: 1/4" - 2" (8 - 50mm) Suffix: VAST - quarter -turn ball valves S - strainer LF - without shutoff valves PC - internal polymer coating Prefix: U - union connections Available Models: 21/2" - 3" (65 - 80mm) Suffix: NRS - non -rising stem resilient seated gate valves OSY - UUFM outside stem and yoke resilient seated gate valves S -FDA - FDA epoxy coated strainer QT -FDA - FDA epoxy coated quarter -turn ball valves LF - without shutoff valves Note: The installation of a drain line is recommended. When install- ing a drain line, an air gap is necessary (see ES -AG). Materials: 1/4" - 2" (8 - 50mm) Lead Free' cast copper silicon alloy body construction, silicone rubber disc material in the first and second check plus the relief valve. Replaceable polymer check seats for first and second checks. Removable stainless steel relief valve seat. Stainless steel cover bolts. Standardly furnished with NPT body connections. Model LF009QT furnished with quarter -turn, full port, resilient seated, Lead Free' cast copper silicon alloy body ball valve shutoffs. Materials: 2'/2" and 3" (65 - 80mm) • (FDA approved) Epoxy coated cast iron unibody with plastic seats • Relief valve with stainless steel seat and trim • Lead Free cast copper silicon alloy body ball valve test cocks Air Gaps and Elbows Pressure / Temperature Sizes 1/4" - 2" (8 - 50mm) Suitable for supply pressure up to 175psi (12 bar). Water temperature: 33°F - 180°F (0.5° - 75°C). Sizes 21/2" and 3" (65 and 80mm) are suitable for supply pressures up to 175psi (12.1 bar) and water temperature at 110°F (43°C) continuous, 140°F (60°C) intermittent. Standards USC ASSE No. 1013 AWWA C511 CSA B64.4 IAPMO File No. 1563. G & co ® "Pc Approvals ASSE, AWWA, CSA, IAPMO Approved by the Foundation for Cross -Connection Control and Hydraulic Research at the University of Southern California. Approval models QT, PC, NRS, OSY. UL Classified 2'/2" and 3" (65 and 80mm) with OSY gate valves. 3/4" - 2" (20-50mm) without shutoff valves (-LF) (except LF009M3LF) MODEL DRAIN for 909, 009 and 993 sizes A B in. mm in. mm in. mm lbs. kgs. 909AGA/4"—'/2" 009, '/2 13 2% 60 3'/8 79 0.625 0.28 3/4" 009M2/M3 909AGC 1/411-11,009/909, 1 25 T/4 83 4% 124 1.5 0.68 1 "-1'/2" 009M2 909AGF 1'/4"-2" 009M1, 2 51 4% 111 63/4 171 3.25 1.47 1'/4"-3" 009/909, 2" 009M2, 4"-6" 993 909AGK 4"-6" 909, 3 76 6% 162 9% 244 6.25 2.83 8"-10" 909M1 909AGM 8"-10" 909 4 102 7% 187 11'/4 286 15.5 7.03 909ELA '/4"-'/2" 009 3/4" 009M2/M3 - - - - - - - - 909ELC %11-111009/909 - - 23% 60 2% 60 0.38 0.17 ' 909ELF 1'/4"-2" 0091V11, - - 35% 92 3% 92 2 0.91 1'/4"-2" 009/909, 2" 009M2 4"-6" 993 909ELH 2'/2"-3" 009/909 - - - - - - - - Vertical Dimensions and Weight: 1/4" - 2" (8 - 50mm) LF009 LF009 1/4" — 2" Dimensions and Weight: 2'/2" and 3" (65 and 80mm) LF009 E� p Ni N L ' E --------- M ---------- ------------- — A C open 0 0 � p`� 0 0 1 ----- g ------ STRAINER SIZE DIMENSIONS (APPROX.) M N Nit in. mm in. mm in. mm in. mm lbs. kgs. 21/2 65 10 254 61/2 165 93/4 248 28 12.7 3 80 10'/a 257 7 178 10 254 34 15.4 tClearance for servicing Watts G-4000 Series QT — Ball Valves Capacity Performance as established by an independent testing laboratory kPa psi 'Ya" (8mm) LF009QT 138 20 117 17 _ 96 14 76 11 55 8 35 5 0 .25 .60 .75 1 1.17 gpm AP 0 .95 1.9 2.9 3.8 4.5 Ipm kPa psi 3/a" (1Omm) LF009QT 138 20 117 17 - 96 14 76 11 00�- 55 8 35 5- 0 .25 50 .75 1 1.25 1.50 2.5 3.1 gpm AP 0 .95 1.9 2.9 3.8 4.8 5.7 9.4 11.8 Ipm kPa psi V " (15mm) LF0090T 172 25 138 20 103 15 69 10 35 5 0 1 2.5 5 7.5 10 12.5 15 gpm AP 0 3.8 9.5 19 28.5 38 47.5 57 Ipm 5 7.5 15 fps 1.5 2.3 4.6 mps kPa psi 207 30 165 24 124 18 83 12 41 6 3/a" (20mm) LF009M3QT 0 OL l 0 2 6 10 14 18 22 26 30 34 38 42 46 gpm AP 07.6 23 38 53 68 84 99 114 129 144 160175 Ipm 7.5 15 fps 2.3 4.6 mps 1- (25mm) LF009M20T kPa psi 207 30 172 25 138 20 103 15 69 10 35 5 0 0 0 5 10 20 30 40 50 60 70 80 gpm AP 0 19 38 76 114 152 190 228 266 304 Ipm 7.5 15 fps 2.3 4.6 mps IMWArM A Watts Water Technologies Company "Typical maximum system flow rate (7.5 feet/sec., 2.3 meters/sec.) kPa psi 1'/a" (32mm) LF009M20T 172 25 138 20 103 15 69 10 35 5 0 0 �P 0 10 20 30 40 50 60 70 80 gpm 0 38 76 114 152 190 228 266 304 Ipm 5 7.5 10 15 fps 1.5 2.3 3.0 4.6 mps kPa psi 1'/z" (40mm) LF009M20T 207 30 172 25 138 20 103 15 69 10 35 5 0 0 0 10 20 30 40 50 60 70 80 90 100 110120 gpm AP 0 38 76 114 152 190 228 266 304 342 380 418 456 Ipm 5 7.5 10 15 fps 1.5 2.3 3.0 4.6 mps kPa psi 2" (50mm) LF009M20T 207 172 138 103 69 35 0 APO 20 40 60 80 100 120 140 160 180 200 gpm 0 76 152 228 304 380 456 532 608 684 760 Ipm 5 7.5 10 15 fps 1.5 2.3 3.0 4.6 mps kPa psi 2V2" (65mm) LF009 172 25 3" (80mm) LF009 172 25 138 20 20 103 15 103 15 69 10 35 69 10 0 0 �P 0 25 50 75 100 125 150 175 200 225 250 275 300 325 gpm 0 95 190 285 380 475 570 665 760 855 950 104511401235 35 5 5 7.5 10 fps 1.5 2.3 3.0 mps 00- 0 00 25 50 75 AP 0 05 10- 295 5 1.5 100 125 380 475 7.5 2.3 150 570 10 3.0 175 200 225 250 gpm 665 760 885 950 Ipm 15 fps 4.6 mps kPa psi 3" (80mm) LF009 172 25 138 20 103 15 69 10 35 5 0 0 �P 0 25 50 75 100 125 150 175 200 225 250 275 300 325 gpm 0 95 190 285 380 475 570 665 760 855 950 104511401235 Ipm 5 7.5 10 fps 1.5 2.3 3.0 mps USA: Tel: (978) 688-1811 • Fax: (978) 794-1848 • www.watts.com Canada: Tel: (905) 332-4090 • Fax: (905) 332-7068 • wwwmatts.ca ES-LF009 1318 © 2013 Watts AEA BA10 ) FILIE A THERMAC01 Technology Installation & Operation Instructions For Big Dipper 40000 Series Internal Strainer (IS) Units Models W -200 -IS, W -250 -IS, W -350 -IS and W -500 -IS (Including 230 VAC Units) REVIEWED FOR CODE COMPLIANCE . APPROVED NOV 0 2 2016 City of Tukwila BUILDING DIVISION A J�0`NG AND DRq/h9 Q /NSTI7UTE 0 RECEIVED OCT 10 2016 TUKWILA PUBLIC WORKS RECEIVED CITY OF TUKWILA OCT 0 l 2016 PERMIT CENTER f%CTiQN C US* LTR# *Please consult Thermaco, Inc. for specific models tested, certified and/or listed by these organizations. Copyright @2016 Big Dipper® Thermaco, Inc. • P.O. Box 2548 • Asheboro, NC 27204 Toll Free: (800) 633-4204 • V: (336) 6 "1 F: ( 6)v126- 573 info@thermaco.com . vm ig- er. LN. 540000 B/G® O'TechnologyATHERMAC�/ 40000 Series Table of Contents IS System Overview ••••••••••••••• .3 IS System Maintenance • • • • • • • • • • • • • • .4 IS Digital Control Operation • • • • • • • • • • .5 IS System Troubleshooting • • • • • • • .... ..7 How To Reverse IS System Operation • • • • • • • 8 Plumbing Installation .. . . . . . . . . . . . . ..9 Vented Flow Control Installation......... .11 Electrical Installation .... ..... ...... .12 IS System Wiring Diagram ... . .. .. .... .13 IS Component Identification........ ....14 IS Replacement Parts .. . . . . . . . . . . . . ..16 Limited Warranty• • • • • • • .. . ... ......17 ©2016 Thermaco, Inc. All rights reserved • Patented/Patents Pending • Specifications subject to change without notice Thermaco, Inc. • 646 Greensboro St. • Asheboro, N. C. 27204-2548 • Phone (336) 620-4651 1 MNL-ISPS40000 2 Aff/a ® 40000 Series ATHERMA�Oe1Technology Big Dipperg Internal Strainer (IS) System Overview Big Dipper Internal Strainer System Overview The Thermaco, Inc. Big Dipper® Automatic Grease and Oils grease & oils from kitchen drain water flows. As most foo service facility managers already know, grease buildup within building's plumbing drainage system is a major cause of prok lems due to drain line blockages. These problems jeopardiz normal operations as well as create health and safety hazarc within the facility itself. The proper installation of a Big Dipper System can reduce c eliminate grease problems. Use of the Big Dipper assure minimization and/or elimination of costly sewer surcharges an, fines through efficient separation and removal of free-floatirn grease & oils. In addition, the Big Dipper also helps reduce c. eliminate pumping and disposal costs associated with conventional grease separators or intercep- tors. The recovered grease & oils are substantially water -free and are suitable for recycling by local rendering and/or biodiesel companies. The Big Dipper system is an automatic, self-cleaning device. As greasy kitchen effluent drains from kitchen fixtures, the unit contains the grease & oils. These separate from the effluent and rise to the surface of the separator tank. The unit automatically skims the contained grease & oils and transfers the grease & oils to a collection container. A digital control maintains the self cleaning operation, activating the skimming wheel periodically based on the setting chosen. Only the "cleaned" water exits the unit and flows into the facility drain lines. The Big Dipper IS automatic systems operate most efficiently when servicing single fixtures such as a 1 to 3 -compartment sink or a pre -rinse station. The Big Dipper system's compact footprint allows installation directly at the source where grease problems originate. The system design also allows easy maintenance and operation requiring only a minimal amount of daily and weekly maintenance to maintain peak operating performance. The Big Dipper system design allows for maximum installation flexibility. Reversing the system op- eration is a simple as rotating the cover assembly of the unit. Hydromechanical grease interceptors*, grease separators, automatic recovery units, grease removal devices and other similar plumbing devices receiving kitchen flows from sinks, floor drains, woks and other food bearing sources may generate odors. There are many factors influencing odor evolu- tion and dissemination. These include room ventilation, kitchen menu, ambient temperatures, ware washing practices, grease/oil input, daily input fluid volume, sanitizers, installation plumbing design and product maintenance/upkeep. Odors are usually prevented by good area ventilation, frequent fluid inputs, good product maintenance practices and proper product installation. Additional steps, including aeration, chlorination, improved area ventilation and additional maintenance control, may be needed at some sites. `Devices formerly referred to as grease traps are now called hydromechanical grease interceptors. ©2016 Thermaco, Inc. All rights reserved • Patented/Patents Pending • Specifications subject to change without notice Thermaco, Inc. • 646 Greensboro St. • Asheboro, N. C. 27204-2548 • Phone (336) 629-4651 1 MNL-ISPS470 ® BIC 40000 Series ATHERMACO°Technology Big DipperO Internal Strainer (IS) System Maintenance Big Dipper° Internal Strainer (IS) System Maintenance *CAUTION! DISCONNECT POWER TO UNIT BEFORE CLEANING to prevent damage to the unit and personal injury *NOTE: Before energizing unit after cleaning, fill tank with water to protect wipers and heater from damage Daily Maintenance: (A) Empty the clear plastic grease/oils collection container (located beside the unit) prior to its be- coming full once each day. The Big Dipper recovers grease and oil virtually water -free so that they can be recycled. The collector container should be washed periodically so as to maintain the easy viewing translucent characteristic of the collector. (B) The internal strainer basket should be removed and emptied into a garbage container by shaking briskly. Wash the inside and outside surfaces of the strainer after emptying. Weekly Maintenance: (A) Check the collection trough and the wiper blades for any solids build-up. Wipe off any accumulated deposits and assure that the wiper blades are clipped in place properly. (B) Press the Start button (on the bottom of the user interface) momentarily to ensure that the motor and skimming wheel are still operating correctly. (C) Check the thickness of the grease layer at the top of the unit. There should be no appreciable amount of grease or oil left in the tank immediately after the daily automatic skimming cycle. If there is more than a 1/2" (13 mm) thick layer of grease after the skimming cycle, this indicates a need to increase the skimming time. Increase the digital control settings accordingly until a clean unit ap- pearance is obtained after the automatic skimming cycle. A simple guide is to change to the next higher setting (Light [1] to Moderate [II] or Moderate [II] to Heavy [III]) and run for a period of time until enough grease is being skimmed from the tank. Quarterly Maintenance: (A) The internal strainer basket in the unit is designed to remove incidental solids from kitchen drain flows. Over a period of time, sediment consisting of very fine particles may begin to accumulate on the bottom of the unit. If this build-up is allowed to continue, it may eventually block the outlet baffle. To prevent this from occurring, remove the lid and stir the bottom of the unit with a long handled spatula while water is flowing to flush out the sediment. Occasionally drain and clean the unit thoroughly. Properly used, a wet -vac may be appropriate for this purpose. ©2016 Thermaco, Inc. All rights reserved • Patented/Patents Pending • Specifications subject to change without notice Thermaco, Inc. • 646 Greensboro St. • Asheboro, N. C. 27204-2548 • Phone (336) 629-4651 1 MNL-ISPS40000 4 ® BIC 40000 Series A THERMACO°' Technology Big Dipper IS System Digital Control Operation Digital Control Operation (Default Modes Timed Skimming Default Through the "User Interface" three levels of skimming may be selected in the "default" mode. By selecting one of the skimming buttons — I, ll, or III - the skimming cycle (see table below) is activated. The LED associated with the selected button is illuminated continuously as an indicator of the selected skim cycle and as a "power on" indicator. If the skimming level is changed during an active skimming cycle, the next active skim cycle will be at the new setting (The LED associated with the newly selected level will change immediately). If the skimming cycle is changed between active skimming cycles the next skim cycle will be at the new level. Motor Exercising For all default mode skimming levels, the motor will be energized for 30 seconds every 9.5 hours. Only the motor will be energized (no heater operation) atthese exercising times. Light Setting: Recommended for Light Grease Output (Small Cafes, Coffee/ Ice Cree Moderate Setting: Recommended for Moderate Grease Output (Quick and Full -Service restaurants***) Heavy Setting: Recommended for Heavy Grease Output (Steakhouses, Buffets, crease sites***) is Press to begin a cycle early or to test operation.. Start Button Operation Any time the start button is depressed the "time between skims" the digital control goes to its maximum time and operation begins for the selected skim level. After this skimming cycle the normal time delay to the next skim cycle is used (skim cycle resets when the start button is depressed). Heater Operation The heater operates under Thermistor control any time the skimmer motor is energized and anytime the liquid temperature drops to 40° F to prevent liquid from freezing. Contact Thermaco for programming alternative heater settings. Default Modes - Normal Operation* Button Selected Skim Time Delay Between Skims** Light (1) 15 Minutes 76 Hours Moderate (11) 30 Minutes 19 Hours Heavy (III) 1 60 Minutes 1 19 Hours * For Extreme Conditions see next page. '* Delay between Skims is the time from the start of the 1 st skim to the start of the next skim. '** Only examples, actual mode needed will vary depending upon menu, warewashing procedures, etc. ©2016 Thermaco, Inc. All rights reserved - Patented/Patents Pending - Specifications subject to change without notice Thermaco, Inc. - 646 Greensboro St. - Asheboro, N. C. 27204-2548 - Phone (336) 629-4651 1 MNL-ISPS400i 0/0 ® 40000 Series ATHERMA�0'Technology Big DipperO IS System Digital Control Operation Digital Control Operation (Extreme Modes Extreme Operation For Food Service Operations which produce more grease and need additional run-time, the 40000 Series Big Dipper provides additional modes for extreme operation. In order to access these modes: 1. Remove power from CLA by unplugging unit or lifting it to disengage the safety switch (found on underside of the back of assembly). 2. Reapply power while holding down the Heavy Mode (III) Button. 3. The button (III) will blink temporarily, indicating which operation level has been selected. 4. Select desired mode at skim times/frequencies listed below. Extreme Modes Button Selected Skim Time Delay Between Skims* Light (1) 90 Minutes 19 Hours Moderate (II) 120 Minutes 19 Hours Heavy (III) 1 120 Minutes 1 9.5 Hours * Delay between Skims is the time from the start of the 1 st skim to the start of the next skim. To return to Default Modes, follow the instructions above, but press the Light Mode (1) Button instead of the Heavy Mode (III) Button. The Light Mode (1) Button will temporarily blink to indicate this operational level has been selected. Hold down Light Hold down Heavy Mode (1) Button Mode (III) Button when connecting when connecting power to unit to O DO power to unit to switch back to a switch to extreme default modes. modes. Cts ©2016 Thermaco, Inc. All rights reserved • Patented/Patents Pending • Specifications subject to change without notice Thermaco, Inc. • 646 Greensboro St. • Asheboro, N. C. 27204-2548 • Phone (336) 629-4651 1 MNL-ISPS40000 6 Agfa O�TechnologATHERMACO� R® Big Dipper unit overflows (1) Check to see that the outlet pipe is not reduced to a smaller size, the outlet piping is vented, has as few 90 degree outlet turns as possible, and that no "P" trap is installed on the outlet. Re -plumb the piping, if neces- sary. Check outlet piping for clogs. Have a plumber clean the line, if necessary. (2) Make sure that the solids strainer is in place and emptied daily. (3) Check the bottom of the grease chamber for exces- sive solids and silt buildup which may be blocking the outlet baffle. Disconnect the power and use a long handled spatula or similar instrument to stir the bottom while water flows through the unit. If necessary, drain and clean the sediment from the unit. To prevent recur- rence, schedule this cleaning to be done on a regular basis (properly used, a wet vac may be appropriate for cleaning sediment from the bottom of the unit). (4) Make sure the flow rate to the unit does not exceed the maximum flow rate, which is shown on the nameplate. If necessary, have a plumber install an approved flow control to restrict the inlet flow to the specified level or install a properly sized Big Dipper for the application. Excessive water observed in the grease collection container (1) Check Digital Control for excessive `on" time. Unit will pick up incidental water after all grease is removed. If necessary, reduce the digital control setting (i.e. Moderate [II] to Light [1]) until no water is observed in the grease collection container. (2) Make sure that the water flow to the unit does not exceed the rated flow and there are no drain line clogs downstream from the unit. No grease is collected in the container (1) Check to be sure the power is on and the correct setting is chosen. One of the setting buttons should be illuminated. If none of the setting buttons are illuminated, the unit is not powered. (2) Lift the sump cover and clean away any buildup that may be present on the wiper blades or collection trough. Make sure the wiper blade(s) are properly in place on the skimmer wheels. Replace wiper blades when worn or warped. 40000 Series Big Dipper° IS System Troubleshooting (3) Press the Start Button on the bottom of the user inter- face to ensure that the skimming wheel turns. CAUTION: Keep your hands away from moving parts to avoid possible injury. If the skimmer motor does not come on, the motor assembly may need to be replaced. (4) Check for congealed grease in the unit. If the Big Dipper's heating element is not warming the unit, the heating element may need to be replaced. (5) Some sites do not generate enough grease to be captured by the skimming process. Set Control for minimum operation - Setting [1] for Light Skimming Operation. Objectionable odor (1) Make sure grease/oil is being skimmed properly from the unit. (2) Check Digital Control for excessive "on" time. Unit will pick up incidental water after all grease is removed. If necessary, reduce the digital control setting (i.e. Moderate [II] to Light [1]) until no water is observed in the grease collection container. (3) If excessive sediment has collected on the bottom of the unit, clean the unit as described in item 3 in "Big Dipper unit overflows." (4) Clean the solids strainer and grease collection container more frequently. (5) Grease interceptors, grease traps, automatic re- covery units, grease removal devices and other similar plumbing devices receiving kitchen flows from sinks, floor drains, woks and other food bearing sources may generate odors. There are many factors influencing odor evolution and dissemination. These include room ventilation, kitchen menu, ambient temperatures, ware washing practices, grease/oil input, daily input fluid vol- ume, sanitizers, installation plumbing design and product maintenance/upkeep. Odors are usually prevented by good area ventilation, frequent fluid inputs, good product maintenance practices and proper product installa- tion. Additional steps, including aeration, chlorination, improved area ventilation and additional maintenance control, may be needed at some sites. ©2016 Thermaco, Inc. All rights reserved • Patented/Patents Pending • Specifications subject to change without notice Thermaco, Inc. • 646 Greensboro St. • Asheboro, N. C. 27204-2548 • Phone (336) 629-4651 1 MNL-ISPS4001 g/aP//� R° ATHERMACology 1) 3) 40000 Series How To Reverse Big Dipper° IS System Operation How To Reverse Big DipT° IS System Unit Operation *ALWAYS UNPLUG UNIT BEFORE REMOVING LID *SYSTEM WILL NOT OPERATE UNLESS CENTER MODULE IS IN PLACE 1) Unlatch the Unit lid. Pull the side wings outward. Heater 3) Rotate the center module ° 180. �J O j O O 2) E 1U C 0o r c3 o c U 2) Lift the center module up off of the unit, ensuring clearance for the heater. 4) 4) Lower the center module back down on top of the unit. Move the two side wings back into place & fasten all latches. ©2016 Thermaco, Inc. All rights reserved • Patented/Patents Pending • Specifications subject to change without notice Thermaco, Inc. • 646 Greensboro St. • Asheboro, N. C. 27204-2548 • Phone (336) 629-4651 1 MNL-ISPS4001 Ble 0 40000 Series A THERMAC01 TechnologyMM Big DipperO IS System Plumbing Installation Big Dipper° IS System Plumbing Installation Locating the Unit To minimize grease- build-up in piping, a Big Dipper system should be located as close as possible to the fixture it is serving. The sys- tem should be visible and easily accessible for maintenance and inspection. The unit must be in a level position. Be sure to check the Specification Sheet for your model for the exact clearances needed for installation. If the system is located directly on the floor, the bottom should be sealed to the floor with an approved silicone type sealant. Make sure the height above the Internal Strainer access cover is enough to remove the strainer basket. Inlet/Outlet Piping The inlet and outlet piping connections require flexible sleeve pipe couplings. Keep outlet pip- ing as straight as possible. Use only "sweep" connections. Do not reduce the pipe sizing on the outlet piping. Do not install "P" trap on outlet connection of system. (Note: The system already has a internal gas trap) Flow Controls Big Dipper systems are equipped with an internal flow control located inside the inlet end of the system. Verify its location and placement prior to connecting the inlet piping. Fill Unit With Water Before Applying Power Big Dipper systems, equipped with an electric heating element, MUST be filled with water before energizing the power to the system. Failure to do so may damage the electric heating element. These elements will NOT be replaced under Thermaco's Warranty. Ventina the Outlet An outlet vent or approved vacuum breaker of at least 1/2 the diameter of the system's outlet connection must be present as close as pos- sible to the Big Dipper outlet to prevent possible siphonage problems. Failure to provide a vent for the system voids Thermaco's Warranty for the system. For Hiah Head Height Applications Over Six (6) Feet (1.95 m) Big Dipper systems are equipped with an internal flow regulator located inside the inlet end of the system. Verify its location and placement prior to connecting the inlet pip- ing. If your code requires a vertical type flow regulator, an approved control with a flow rat- ing matching the system's flow rate should be used. Note: When a Big Dipper is servicing multiple fixtures, some codes require separate flow controls for each fixture. See following page for suggested high head height flow regulation installation. Do Not Use With Food Grinders. Potato Peelers or Waste Disposal Units If the system is connected to a Waste Disposal Unit, Garbage Grinder or Potato Peeler, Ther- maco's Warranty will be void. Note: Drawing for reference only. Equipment must be installed in compliance with all applicable laws, regulations and codes, includ- ing plumbing codes. Installation should be performed by a qualified plumber. ©2016 Thermaco, Inc. All rights reserved - Patented/Patents Pending - Specifications subject to change without notice Thermaco, Inc. - 646 Greensboro St. - Asheboro, N. C. 27204-2548 - Phone (336) 629-4651 1 MNL-ISPS400i Bla ® 40000 Series ATHERMAC01TechnologyPM Big Dipper"' IS System Plumbing Installation Sometimes space restrictions require the installation of Big Dipper units in basement locations where significant head pressure becomes a factor. The Big Dipper' VFCA Vented Flow Control module provides an option for use with installations where a significant amount of head pressure is present (greater than 6 ft./1.95 m) or where ap- plicable regulations require vented flow controls. A Vented Flow Control helps reduce problems associated with high head pressure and helps slow the drainwater flow down. The VFCA kit contains an appropriate fitting and flow control orifice. Flow Control Vent/Air Intake (Note: Flow Control Vent may be connected to atmosphere vent, facility vent, or code -approved air admittance valve. To be installed above sink flood rim.) Outlet Vent (Note: Vent may be facility vent connection or code -approved air admittance valve) * Installation in high head height locations requires removal of the Internal Flow Control (small rub- ber cap under no -hub coupling over the Inlet). Big Dipper® IS Unit F7FaJ Drainage Piping from Kitchen 14 VFCA-20 Vented Flow Control for W -200 -IS VFCA-25 Vented Flow Control for W -250 -IS VFCA-35 Vented Flow Control for W -350 -IS VFCA-50 Vented Flow Control for W -500 -IS Installations where head height is greater than 6 feet (1.95 m) NOTE: Drawing for reference only. Equipment must be installed in compliance with all applicable laws, regulations and codes, including plumbing codes. Installation should be performed by a qualified plumber. ©2016 Thermaco, Inc. All rights reserved - Patented/Patents Pending - Specifications subject to change without notice Thermaco, Inc. • 646 Greensboro St. • Asheboro, N. C. 27204-2548 - Phone (336) 629-4651 MNL-ISPS400C BleP"Ra ATHERMAC FLOW FROM KITCHEN FLOW CONTROL DISC SUPPLIED BY THERMACO PLACE UPSTREAM OF VENT PIPE AS SHOWN GLUE ALL JOINTS TO SECURE DISC IN PLACE IMPORTANT! 40000 Series VFCA Vented Flow Control Installation Instructions FLOW TO BIG DIPPER® OUT (OPTIONAL) FLOW CONTROL VENT MAY BE CONNECTED TO ATMOSPHERE VENT, FACILITY VENT, OR CODE -APPROVED AIR ADMITTANCE VALVE TO BE INSTALLED ABOVE SINK FLOOD RIM. FLOW CONTROL BODY SUPPLIED BY THERMACO *Air Admittance Valves are not permitted in some locations. Check local plumbing code to determine if they are permitted by state or local plumbing code. The flow control should be installed after the last fixture as close as possible to the under side of the lowest fixture. If the flow control is installed more than 2 feet below the lowest fixture consult the manufacturer for a more restrictive disc. Remove the rubber flow control from the Big Dipper system. Note: This equipment must be installed to comply with all applicable national, state, and local plumbing codes for your area. Installation should only be performed -by a qualified plumber. ©2016 Thermaco, Inc. All rights reserved • Patented/Patents Pending • Specifications subject to change without notice Thermaco, Inc. • 646 Greensboro St. • Asheboro, N. C. 27204-2548 • Phone (336) 629-4651 MNL-ISPS400C ® BIC 40000 Series ATHERMRC01TechnologyXpr Big DipperO IS System Electrical Installation Big Dipper° IS System Electrical Installation i Electrical Panel (NOT SUPPLIED) 115 VAC Circuit, From Ground Fault Circuit Breaker (NOT SUPPLIED) *For 230 VAC Units use 230 VAC Circuit Big Dipper Internal Strainer (IS) Models Big Dipper Internal Strainer Series Models utilize one Push Button Digital Time Controller. The Digital Control is located under the hinged lid of the motor enclosure on top of the lid of Big Dipper (See Digital Control Operation Instructions). The Big Dipper should only be plugged into a properly grounded 3 -prong 115 VAC or 230 VAC outlet. If possible, the power supply outlet for the Big Dipper should be connected to an electrical circuit controlled by a ground fault circuit breaker. One of the setting buttons should be illuminated to show the unit is powered. If none of the setting buttons are illuminated, the unit is not powered. This Big Dipper unit is shipped from the Factory wired for Simultaneous Operation. This means the Heater and Motor operate at the same time under digital control. Continuous Heater Operation is where the Heater is active at all times. To switch to alternative heating programming, please contact a Thermaco representative for furher instructions. Note: The Big Dipper unit will not operate when the lid is removed. Socket Outlet (NOT SUPPLIED) ontrol ged Lid) Big Dipper Electrical Requirements 4.5 Amps @ 115 VAC 50/60Hz (520 Watts) "For 230 VAC Units: 2.3 Amps @ 230 VAC 50/60Hz (520 Watts) Note: Digital Control Supplied with system. Drawing for reference only. Equipment must be installed in compliance with all applicable laws, regulations and codes, including electrical codes. Installation should be performed by a qualified electrician. @2016 Thermaco, Inc. All rights reserved - Patented/Patents Pending • Specifications subject to change without notice Thermaco, Inc. • 646 Greensboro St. • Asheboro, N. C. 27204-2548 • Phone (336) 629-4651 MNL-ISPS400C BICD/ R® A THERMACOa' Technology Wiring Diagram For Big Dipper Models W -200 -IS Through W -500 -IS 40000 Series Big Dipper® IS System Wiring Diagram NOTE: 220-240V Units (International Units) have the following wire color changes: On the POWER SUPPLY CORD: The Black Wire becomes Brown The White Wire becomes Blue The Green Wire becomes Yellow/Green ©2016 Thermaco, Inc. All rights reserved - Patented/Patents Pending - Specifications subject to change without notice Thermaco, Inc. • 646 Greensboro St. • Asheboro, N. C. 27204-2548 • Phone (336) 629-4651 MNL-ISPS40000 13 BlaO/ Ra A THERMAC0" Technology I P; *NotE _ 230 VAC Units use M-58-230 and H-8-230 40000 Series Big Dipper® IS System Electrical Components Control Assembly Part# PCBA-2 Consisting of 9)2016 Thermaco, Inc. All rights reserved - Patented/Patents Pending - Specifications subject to change without notice Thermaco, Inc. • 646 Greensboro St. - Asheboro, N. C. 27204-2548 - Phone (336) 629-4651 MNL-ISPS40000 14 ® BIC 40000 Series 01 Technology Big DipperO IS System Component Identification Big Dipper° IS System Component Identification over SC -1 Electrical sure Digital nbly FEEA-1 riper Assembly WA -4 ©2016 Thermaco, Inc. All rights reserved • Patented/Patents Pending • Specifications subject to change without notice Thermaco, Inc. • 646 Greensboro St. • Asheboro, N. C. 27204-2548 • Phone (336) 629-4651 MNL-ISPS40000 15 ® 40000 Series B/GO�TechnologyATHERMAC�R Big Dipper° IS System Replacement Parts Big Dipper° IS System Replacement Parts SOLIDS STRAINER BASKET FOR MODEL# USE PART# W -200 -IS THROUGH W -250 -IS ST -21 W -350 -IS & W -500 -IS ST -62 USER INTERFACE (Under Cover) FOR ALL MODELS USE PART# PCBA-2 (INCLUDES USER INTERFACE, RIBBON CABLE, PRINTED CIRCUIT BOARD AND THERMISTOR) LID GASKET PART# RG -7 GREASE/OILS COLLECTION CONTAINER WHEEL WIPER ASSEMBLY (1 per unit) FOR W -200 -IS THROUGH W -500 -IS USE PART# GC -7 PART# WWA-4 WHEEL DRIVE SPROCKET (1 per unit) PART# WDS-3 SKIMMING WHEEL ASSEMBLY (1 per unit) PART# PDA -3 SAFETY SWITCH PART# MSS -7 HEATER GASKET PART# HTG-300 ©2016 Thermaco, Inc. All rights reserved • Patented/Patents Pending • Specifications subject to change without notice Thermaco, Inc. • 646 Greensboro St. • Asheboro, N. C. 27204-2548 • Phone (336) 629-4651 MNL-ISPS4000 NOT SHOWN: MOTOR (1 per unit) PART# M-58 ROPERLY DISPOSE OF M-58-230 in 230 VAC Units CONTENTSo DAILY HEATER (1 per unit) PART# H-8 —9� 'L� H-8-230 in 230 VAC Units .=r'� 6 L= =4QL 4L- INTERNAL FLOW CONTROL (1 unit) per -3QL 3L- PART# MFC -20 FOR W -200 -IS ZLm PART# MFC -25 FOR W -250 -IS �n ISL PART# MFC -35 FOR W -350 -IS PART# MFC -50 FOR W -500 -IS LID GASKET PART# RG -7 GREASE/OILS COLLECTION CONTAINER WHEEL WIPER ASSEMBLY (1 per unit) FOR W -200 -IS THROUGH W -500 -IS USE PART# GC -7 PART# WWA-4 WHEEL DRIVE SPROCKET (1 per unit) PART# WDS-3 SKIMMING WHEEL ASSEMBLY (1 per unit) PART# PDA -3 SAFETY SWITCH PART# MSS -7 HEATER GASKET PART# HTG-300 ©2016 Thermaco, Inc. All rights reserved • Patented/Patents Pending • Specifications subject to change without notice Thermaco, Inc. • 646 Greensboro St. • Asheboro, N. C. 27204-2548 • Phone (336) 629-4651 MNL-ISPS4000 0/0�//� Ra A THERMACOp' Technology 40000 Series Big Dipper° Limited Warranty & Remedy Thermaco, Inc. warrants to the original user that the products manufactured by it delivered with this warranty shall be free from material defects in workmanship and materials for a period of 12 months from the date of invoice to the distributor (if sold by an authorized Thermaco distributor) or the date of invoice to the purchaser (if sold directly by Thermaco, Inc.), but in no event longer than 15 months from date of shipment from Thermaco's production facility. Any claim must be made in writing to Thermaco at 646 Greensboro Street, Asheboro, NC 27203 promptly after discovery of the defect and within the applicable warranty period. The product must be delivered, prepaid, to Ther- maco, together with proof of purchase, the serial number from which the item was removed and a return authoriza- tion number issued by Thermaco. If Thermaco determines upon examination that the component is defective and that the warranty conditions are met, Thermaco's sole obligation under this warranty, and the purchaser's sole and exclusive remedy, is the repair or replacement, at Thermaco's option, of the defective component, including parts and labor. The replacement will be furnished F.O.B. point of shipment. If Thermaco determines that the component is not defective or that the other conditions of this warranty are not met, then any return of such part to the purchaser shall be at purchaser's cost. This warranty shall not cover any defect in otherwise covered products resulting directly or indirectly from: (i) failure to properly install, operate or maintain the product in accordance with Thermaco's instructions and procedures, including, without limitation, use in excess of rated flow, operation without digital control, improper electrical service, use to remove emulsified fats and oils or use that fails to comply with applicable laws, regulations or codes; (ii) dam- age in transit, handling or installation; (iii) modifications, adjustments, repairs, or alterations made by unauthorized persons; or (iv) other causes not arising out of defects in workmanship or materials. Thermaco shall not be respon- sible for damage to products resulting from vault flooding, sewer line back-up, pumping or lift station failure, ambient water flow or other sources of water damage. This warranty does not cover equipment or parts not manufactured by Thermaco. Purchaser's costs relating to any service, adjustment, removal, repair, packing, or otherwise incurred with respect to the defect prior to submission for warranty are the responsibility of purchaser. No distributor, sales person or other person is authorized to make any warranty statements on behalf of Thermaco regarding Thermaco products other than as set forth in this warranty. This statement of warranty supersedes any quote, brochure, or other statement or document with respect to warranty of Thermaco products. EXCEPT AS EXPRESSLY SET FORTH ABOVE, THERMACO, INC. MAKES NO REPRESENTATIONS, WAR- RANTIES OR GUARANTEES, EITHER EXPRESSED OR IMPLIED, INCLUDING, WITHOUT LIMITATION, AS TO MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE, WHETHER OR NOT THERMACO HAD KNOWLEDGE OF PURCHASER'S PARTICULAR REQUIREMENTS OR NEEDS, OR WITH RESPECT TO ODOR GENERATION OR OTHER INCIDENTALS RELATING TO USE OF THE PRODUCT. The sole and exclusive remedy with respect to this warranty any other claim relating to defects or any other con- dition or use of Thermaco products, however caused, and whether such claim is based upon warranty, contract, tort, strict liability or any other theory, is LIMITED to the repair or replacement of the product, excluding labor or any other cost to remove or install said the product or, at Thermaco's option, repayment of the purchase price. IN NO EVENT SHALL THERMACO, INC. BE LIABLE, WHETHER IN CONTRACT, WARRANTY, TORT (INCLUDING NEGLIGENCE), STRICT LIABILITY, INDEMNITY OR ANY OTHER LEGAL THEORY, FOR INCIDENTAL OR CON- SEQUENTIAL DAMAGES, OR FOR ANY OTHER LOSS OR COST OF A SIMILAR TYPE. UNDER NO CIRCUM- STANCES WILL THE AGGREGATE LIABILITY OF THERMACO FOR ANY CAUSE OF ACTION RELATED TO THE PRODUCTS COVERED HEREBY EXCEED THE NET PURCHASE PRICE RECEIVED BY THERMACO FOR THE PRODUCTS. Any action or suit by purchaser against Thermaco relating to Thermaco products must be brought within one (1) year of the date of the invoices referenced above. The exclusions and limitations set forth herein are separate and independent from any remedies which purchaser may have hereunder and shall be given full force and effect whether or not any or all such remedies shall be deemed to have failed of their essential purpose. ©2016 Thermaco, Inc. All rights reserved • Patented/Patents Pending • Specifications subject to change without notice Thermaco, Inc. • 646 Greensboro St. • Asheboro, N. C. 27204-2548 • Phone (336) 629-4651 MNL-ISPS400C 0 Hermanson 10/05/16 Hermanson Company LLP tel 206-575-9700 1221 2nd Avenue North fax 206-575-9800 Kent, WA 98032 TO City of Tukwila — Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, WA 98188 PROJECT: BECU Expresso Stand MEMO #: Permit# PG 16-0144 SUBJECT: Correction Notice #1: Plumbing Dear Bill Rambo, Allen Johannessen, and Joanna Spencer, The following are responses to the comments dated 9/28/16. COT BUILDING REVIEW COMMENT 1: Please provide manufacturers installation and specifications sheets or manual. Provide a clearer diagram for the drain waste and vent system to and from the grease interceptor. (2015 UPC Chapter 1014 & 1014.3) HERMANSON RESPONSE: Please see Grease Trap detail 3/P5.01 on added sheet P5.01 for a clearer diagram of the grease trap and see attached manufacturer's information on the grease trap. COT PW COMMENT 1: Permit covers work inside the detached coffee kiosk. Submit spec/cut sheets for the proposed grease trap. HERMANSON RESPONSE: Please see attached cutsheet of proposed grease trap. COT PW COMMENT 2: Submit cut sheets for the proposed Reduced Pressure Backflow Assemblies: RPBP-1 and RPBP-2. Since both of them are going to be installed inside a cabinet, please add a note how both backflows will drain. HERMANSON RESPONSE: Please see revised , I ST FLOOR PLAN — PLUMBING" with note stating indirect drainage to nearby floor sink. Please see attached RPBP cutsheets of Watts ES-LF009. COT PW COMMENT 1: Detail 2/P2.01 calls for Double Check Valve Assembly (DCVA) however, 1St FLOOR PLAN calls for two RPBPs. Is there a Double Check Valve Assembly (DCVA) being installed as well? HERMANSON RESPONSE: The two backflow devices will be reduced pressure backflow preventers (RPBP). Please see revised detail 2/P2.01. Mechanical Construction, Engineering and Service www.hermanson.com * Hermanson Sincerely, HERMANSON COMPANY, LLP David Norris Mechanical Engineer Attachment: Revised BECU Coffee Kiosk plans Grease trap and RPBP cutsheets Copy: FILE PM at Hermanson — Brian Morant, HERMANSON COMPANY Subdivision Name Subdiv Building Name �2 i_1 (if applicable) F' Owner's Phone Number (with Area Code) Property Contact Phone Number (with Area Code) Owner's Mailing Address .amu Lot # Block # A. Fixture Units Fixture Units x Number of Fixtures = Total Fixture Units Kind of Fixture Fixture Units No. of Fixtures Total Public Private Public Private Fixture Units King County 4- Department of Natural Resources and Parks Shower, per head Wastewater Treatment Division Non -Residential 2 Sewer Use Certification 2 • To be completed for all new sewer connections, reconnections or change of use of existing connections. 1 • This form does not apply to repairs or replacements of existing sewer connections within five years of disconnect. 2.5 Please Print or Type Clotheswasher or laundry tub r r 2 Property street Address " r' (%AX I�a CA_ �ii Jf L V 'L'u City State ZIP Sink, kitchen 3 Owner's Name` Sink, other (service) Subdivision Name Subdiv Building Name �2 i_1 (if applicable) F' Owner's Phone Number (with Area Code) Property Contact Phone Number (with Area Code) Owner's Mailing Address .amu Lot # Block # A. Fixture Units Fixture Units x Number of Fixtures = Total Fixture Units Kind of Fixture Fixture Units No. of Fixtures Total Public Private Public Private Fixture Units Bathtub and Shower 4- 4 Shower, per head 2 2 Dishwasher 2 2 Drinking fountain (each head) 1 .5 Hose bibb (interior) 2.5 2.5 Clotheswasher or laundry tub 4 2 Sink, bar or lavatory 2 1 t Sink, Clinic flushing 8 8 Sink, kitchen 3 2 Sink, other (service) 3 1.5 Sink, wash fountain, circle spray 4 3 Urinal, flush valve, 1 GPF 5 2 Urinal, flush valve, >1 GPF 6 2 Urinal, waterless 0 0 Water closet, tank or valve, 1.6 GPF 6 3 Water closet, tank or valve, >1.6 GPF 8 4 Total Fixture Units l� Residential Customer Equivalent (RCE) 20 fixture units equal 1.0 RCE Total No. of Fixture Units = RCE 20 For King County Use Only Account # No. of RCEs Monthly Rate Property Tax ID #_/ Party to be Billed (if different from owner) City or Sewer District Date of Connection Side Sewer Permit # Please report any demolitions of pre-existing building on this property. Credit for a demolition may be given under some circumstances. Demolition of pre-existing building? ❑ Yes �0 No Was building on Sanitary Sewer? ❑ Yes `❑ No Was Sewer connected before 2/1/00? ❑ Yes ❑ No Sewer disconnect date: Type of building demolished? Request to apply demolition credit to multiple buildings? []Yes ❑ No B. Other Wastewater Flow (in addition to Fixture Units identified in Section A) Type of Facility/Process: Estimated Wastewater Discharge: Gallons/days Residential Customer Equivalents (RCE): 187 gallons per day equals 1.0 RCE Total Discharge (gal/day) RCE 187 C. Total Residential Customer Equivalents: (add A & B) A B r ,=, RCE Pursuant to King County Code 28.84, all sewer customers who establish a new service which uses metropolitan sewage facilities shall be subject to a capacity charge. The amount of the charge is established annually by the King County Council at a rate, per month per residential customer or residential customer equivalent for a period of fifteen years. The purpose of the charge is to recover costs of providing sewage treatment capacity for new sewer customers. All future billings can be prepaid at a discounted amount. All future billings can be prepaid at a discounted amount. Questions regarding the capacity charge or this form should be referred to King County's Wastewater Treatment Division at 206-684-1740. 1 certify that the information given is correct. I understand that the capacity charge levied will be based on this information and any deviation will require resubmission of corrected data foreietermination of a revised capacity charge. Signature of Owner/Representative ` - i../ Date _ p ' I', Print Name of Owner/Representative itA 1058 (Rev. 9/07) Whit Kina Countv Yellow — Local Sewer Aaencv Pink — Sewer Customer „x.. PERMIT CORD '1 r`' PLAN REVIEW/ROUTING SLIP PERMIT NUMBER: PG16-0144 PROJECT NAME: BECU SITE ADDRESS: 12770 GATEWAY DR Original Plan Submittal X Response to Correction Letter # 1 DEPARTMENTS: AT . /*(, Building Division Public Works PRELIMINARY REVIEW: Not Applicable ❑ (no approval/review required) REVIEWER'S INITIALS: DATE: 10/10/16 1 Revision # before Permit Issued Revision # after Permit Issued Fire Prevention ❑ Planning Division ❑ Structural ❑ Permit Coordinator ❑ DATE: 10/11/16 Structural Review Required ❑ DATE: APPROVALS OR CORRECTIONS: DUE DATE: 11/08/16 Approved ❑ Approved with Conditions Corrections Required ❑ Denied ❑ (corrections entered in Reviews) [ (ie: Zoning Issues) Notation: +t fi� OVA Sh 2 REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ptng ❑ PW ❑ Staff Initials: 12/18/2017 PERMIT COORD COPY. PLAN REVIEW/ROUTING SLIP PERMIT NUMBER: PG16-0144 DATE: 09/23/16 PROJECT NAME: BECU SITE ADDRESS: ' 12770 GATEWAY DR X Original Plan Submittal Revision # before Permit Issued Response to Correction Letter # Revision # after Permit Issued DEPARTMENTS: AT Cover (- Buildin Division Fire Prevention Planning Division g � ❑ g ❑ J Cove Public Works Structural ❑ Permit Coordinator PRELIMINARY REVIEW: DATE: 09/27/16 Not Applicable ❑ Structural Review Required ❑ (no approval/review required) REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: DUE DATE: 10/25/16 Approved ❑ Approved with Conditions ❑ Corrections Required �aj— Denied ❑ (corrections entered in Reviews) (ie: Zoning Issues) Notation: REVI:EWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: �"�" Departments issued corrections: Bldg N— Fire ❑ Ping ❑ PW Staff Initials: 12/18/2013 s W�: I, City of Tukwila w ....... ..qs Department of Community Development i G) 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 "" Phone: 206-431-3670 7908 9 Fax: 206-431-3665 Web site: http://www.ci.tukwila.wa.us REVISION SUBMITTAL Revision submittals must be submitted in person at the Permit Center. Revisions will not be accepted through the mail, fax, etc. Date: 1 h h � 1 (, Plan Check/Permit Number: PG 16-0144 ❑ Response to Incomplete Letter # _ ® Response to Correction Letter # 1 ❑ Revision # after Permit is Issued RECEIVED ❑ Revision requested by a City Building Inspector or Plans Examiner CITY OF TUKWILA OCT 0 7 2016 Project Name: BECU PERMIT CENTER Project Address: 12770 Gateway Dr Contact Person: V n i Phone Number: Z,5 9SC4t ---21 Summary of Revision: Sheet Number(s): "Cloud" or highlight all areas of revision Received at the City of Tukwila Permit Cet ❑ Entered in TRAKiT on \appl icati onsWorms-appl i cations on line\revision submittal Created: 8-13-2004 Revised: If you have any questions, I can be reached at 206-431-3655. Sincerely, Bill Rambo Permit Technician File No. PG 16-0144 6300 Southcenter Boulevard Suite #100 • Tukwila Washington 98188 9 Phone 206-431-3670 • Fax 206-431-3665 City of Tukwila Allan Ekberg, Mayor Department of Community Development Jack Pace, Director September 28, 2016 .KAYLENE NELSON 1221 SECOND AVE N KENT, WA 98032 RE: Correction Letter # 1 PLUMBING/GAS PIPING Permit Application Number PG16-0144 BECU - 12770 GATEWAY DR Dear KAYLENE NELSON, This letter is to inform you of corrections that must be addressed before your development permit can be approved. All correction requests from each department must be addressed at the same time and reflected on your drawings. I have enclosed comments from the following departments: BUILDING - PG DEPARTMENT: Allen Johannessen at 206-433-7163 if you have questions regarding these comments. (GENERAL NOTE) PLAN SUBMITTALS: (Min. size 11x17 to maximum size of 2406; all sheets shall be the same size. New revised plan sheets shall be the same size sheets as those previously submitted.) (If applicable) "STAMP AND SIGNATURES" "Every page of a plan set must contain the seal/stamp, signature of the licensee(s) who prepared or who had direct supervision over the preparation of the work, and date of signature. Specifications that are prepared by or under the direct supervision of a licensee shall contain the seal/stamp, signature of the licensee and the date of signature. If the "specifications" prepared by a licensee are a portion of a bound specification document that contains specifications other than that of an engineering or land surveying nature, the licensee need only seal/stamp that portion or portions of the documents for which the licensee is responsible." It shall not be required to have each page of "specifications" (calculations) to be stamped and signed; Front page only will be sufficient. (WAC 196-23-010 & 196-23-020) (BUILDING REVIEW NOTES) 1. Please provide manufacturers installation and specifications sheets or manual. Provide a clearer diagram for the drain waste and vent system to and from the grease interceptor. (2015 UPC Chapter 1014 & 1014.3) Note: This permit plan review may not be complete as revised plans may require further corrections. PW - PG DEPARTMENT: Joanna Spencer at 206-431-2440 if you have questions regarding these comments. • 1) Permit covers work inside the detached coffee kiosk. Submit spec/cut sheets for the proposed grease trap. 2) Submit cut sheets for the proposed Reduced Pressure Backflow Assemblies: RPBP-1 and RPBP-2. Since both of them are going to be installed inside a cabinet, please add a note how both backflows will drain. 3) Detail 2/P2.01 calls for Double Check Valve Assembly (DCVA) however, I st FLOOR PLAN calls for two RPBPs. Is there a Double Check Valve Assembly (DCVA) being installed as well? Please address the comments above in an itemized format with applicable revised plans, specifications, and/or other documentation. The City requires that two 2 sets of revised plan pages, specifications and/or other documentation be resubmitted with the appropriate revision block. In order to better expedite your resubmittal, a 'Revision Submittal Sheet' must accompany every resubmittal. I have enclosed one for your convenience. Corrections/revisions must be made in person and will not be accepted through the mail or by a messenger service. 6300 South.center Boulevard Suite #100 • Tukwila Washington 98188 9 Phone 206-431-3670 • Fax 206-431-3665 HERMANSON COMPANY LLP Home Fspahol Contact. Safety & Health Washington State Department of Labor & Industries HERMANSON COMPANY LLP Owner or tradesperson Principals NICOLAISEN, KNUT H, PARTNER/MEMBER BROCK, DANIEL L, PARTNER/MEMBER FOX, DEAN M, PARTNER/MEMBER HENGEL, STEPHEN A, PARTNER/MEMBER DYCKMAN,KENNETH A, PARTNER/MEMBER ROBINETT, PAUL J, PARTNER/MEMBER HERMANSON, RICHARD L, PARTNER/MEMBER ALMON, KEVIN, PARTNER/MEMBER (End: 08/05/2010) MACDONALD, JAMES, PARTNER/MEMBER (End: 08/05/2010) Doing business as HERMANSON COMPANY LLP Claims & Insurance 1221 2ND AVE N KENT, WA 98032-2945 206-575-9700 KING County WA UBI No. Business type 602 004 844 Limited Liability Partnership Governing persons CORP HERMANSON LLC HERMANSON GROUP; License Page 1 of 3 Search L&I rt, A -'L Index 1101p Mp I.&I Workplace Rights Verify the contractor's active registration / license / certification (depending on trade) and any past violations. Construction Contractor Active. .......................................................... Meets current requirements. License specialties GENERAL License no. HERMACLO05BJ Effective — expiration 01/11/2000— 08/25/2018 Bond ............ WESTERN SURETY CO $12,000.00 Bond account no. 929381801 Received by L&I Effective date 12/01/2005 01/01/2006 Expiration date Until Canceled Trades & Licensing Help us improve https://secure.Ini.wa.gov/verify/Detail.aspx?UBI=602004844&LIC=HERMACL005BJ&SAW= 11/14/2016 PLUMBING /PIPING ABBREVIATIONS A AI%COMPRESSED AIR INV INVERT ABS ACRRYLONITRITE BUTADIENE STYRENE IRW IRRIGATION WATER ABV ABOVE IW INDIRECT WASTE AC AIR COMPRESSOR KWH KILOWATT HOUR AD ACCESS DOOR AREA DRAIN/AIR DRYER KEC KITCHEN EQUIPMENT CONTRACTOR ADD/ADD'L ADDITION/ADDIIONAL LAV LAVATORY ADJ ADJACENT/ADJUST/ADJUSTABLE/ADJUSTMENT LB/LBS POUND/POUNDS AFF ABOVE FINISHED FLOOR LBS/HR POUNDS PER HOUR AFG ABOVE FINISHED GRADE LPG LIQUID PROPANE GAS AP ACCESS PANEL LPS LOW PRESSURE STEAM ARCH ARCHITECT LWT LEAVING WATER TEMPERATURE ASME AMERICAN SOCIETY OF MECHANICAL ENGINEERS MAX MAXIMUM ATM ATMOSPHERE ATMOSPHERIC MSH 1000 BRITISH THERMAL UNITS PER HOUR BHP BRAKE HORS POWER/BOILER HORSEPOWER MCA MINIMUM CIRCUIT AMPACITY BLDG BUILDING MECH MECHANICAL BOP BOTTOM OF PIPE MFR MANUFACTURER BOT BOTTOM MIN MINIMUM MINUTE BS BLACK STEEL MISC MISCEL NEOUS BTU BRITISH THERMAL UNIT MM MILLIMETERS BTUH BRITISH THERMAL UNITS PER HOUR MPS MEDIUM PRESSURE STEAM COND CONDENSATE MTD MOUNTED CA COMPRESSED AIR N NITROGEN C TO C CENTER TO CENTER NA NOT APPLICABLE CAP CAPACITY/END CAP NC NORMALLY CLOSED/ NOISE CRITERIA CB CATCH BASIN NG NATURAL GAS CENT CENTRIFUGE/CENTRIFUGAL NIC NOT IN CONTRACT CFF CAP FOR FUTURE NO NORMALLY OPEN/ NUMBER CFM CUBIC FEET PER MINUTE NO2 NITROUS OXIDE CI CAST IRON NOM NOMINAL CLG CEILING NP NON -POTABLE CMU CONCRETE MASONRY UNIT NTS NOT TO SCALE CO CLEANOUT/COMPANY/CARBON MONOXIDE 02 OXYGEN CO2 CARBON DIOXIDE OC ON CENTER COL COLUMN OD OUTSIDE DIAMETER/DIMENSION/ OVERFLOW DRAIN CONC CONCRETE ODP OPEN DRIPPROOF COND CONDENSATE ORD OVERFLOW ROOF DRAIN CONN CONNECT CONNECTED CONNECTION OVHD OVERHEAD CONT CONT INU US/CONTIN ATION PD PRESSURE DROP/ PIT DRAIN/ PUMP DISCHARGE CONTR CONTRACTOR PERF PERFORATED COORD COORDINATE PH PHASE CPVC CHLORINATED POLYVINYL CHLORIDE PLBG PLUMBING CT COOLING TOWER POC POINT OF CONNECTION CU CUBIC/COPPER/CONDENSING UNIT PRESS PRESSURE CW DOMESTIC COLD WATER PRV PRESSURE REDUCING VALVE DCVA DOUBLE CHECK VALVE ASSEMBLY PS PRESSURE SWITCH DDC DIRECT DIGITAL CONTROL PSF POUNDS PER SQUARE FOOT DEG DEGREE/DEGREES PSI POUNDS PER SQUARE INCH DI DEIONIZED WATER PSIG POUNDS PER SQUARE INCH GAUGE DIA DIAMETER PVC POLYVINYL CHLORIDE DIFF DIFFERENTIAL/DIFFERENCE/DELTA QTY QUANTITY DISCH DISCHARGE R RISER(RETURN DN DOWN RCVR RECEIVR DOM DOMESTIC RD ROOF DRAIN/ REFRIGERANT DISCHARGE DR DRAIN RECIRC RECIRCULATING/ RECIRCULATE DS DOWNSPOUT RED REDUCE/ REDUCING DWG DRAWING REF REFERENCE DWV DRAIN, WASTE AND VENT REG REGULATOR _ EA EACH RL RAIN LEADER/ REFRIGERANT LIQUID EFF EFFICIENCY RPBP REDUCED PRESSURE BACKFLOW PREVENTER EL ELEVATION RPM REVOLUTIONS PER MINUTE ELEC/ELECT ELECTRICAL/ELECTRIC RS REFRIGERANT SUCTION EMERR EMERGENCY RV RELIEF VALVE ENT ENTERING RVD RELIEF VALVE DISCHARGE EQUIP EQUIPMENT S SOIL/ SUPPLY ERW ELECTRIC RESISTANCE WELDED SAN SANITARY ES EMERGENCY SHOWER SAT SATURATION ET EXPANSION TANK SD STORM DRAIN EWC ELECTRIC WATER COOLER/ S -C SEATTLE N_ CODE EVAPORATIVE WATER COOLER SECT SECTION EWT ENTERING WATER TEMPERATURE SO SCREENED OPENING EXIST EXISTING SOL SOLENOID EXP EXPANSION EXPOSED/EXPLOSION PROOF SOLV SOLENOID VALVE EXT EXTERNAL EXTERIOR SP STATIC PRESSURE/ SPRINKLER F FAHRENH IT/FEED/FILTER SPEC SPECIFICATION FA FACE AREA/FIRE ALARM SQ SQUARE FCO FLOOR CLEAN OUT SQ FT SQUARE FEET FD FLOOR DRAIN SS SANITARY SEWER FDN FOUNDATION STRUC STRUCTURAL FF FINISH FLOOR SUCT SUCTION FFD FUNNEL FLOOR DRAIN TBD TO BE DETERMINED FIC FURNISHED AND INSTALLED BY CONTRACTOR TD TEMPERATURE DIFFERENTIAL FIO FURNISHED AND INSTALLED BY OWNER TEMP TEMPERATURE TEMPORARY FLEX FLEXIBLE THERM THERMOMETER FLR FLOOR TOP TOP OF PIPE FDIC FURNISHED BY OWNER INSTALLED BY OTHERS TP TRAP PRIMER FP FREEZE PROOF/FIRE PROTECTION TPS TRAP SEAL FPM FEET PER MINUTE TYP TYPICAL FPS FEET PER SECOND UG UNDERGROUND FPWH FREEZE PROOF WALL HYDRANT UNO UNLESS NOTED OTHERWISE FS FLOOR SINK, FLOW SWITCH UPC UNIFORM PLUMBING CODE FT FOOT/FEET UR URINAL GA/GAL GALLON UTIL UTILITY GALV GALVANIZED V VENT/ VOLT GD GARAGE DRAIN/GARBAGE DISPOSAL VA VALVE/ VOLT AMPERE/ VACUUM AIR GC GENERAL CONTRACTOR VAC VOLTS ALTERNATING CURRENT/ VACUUM GEN GENERAL VB VACUUM BREAKER GND GROUND VEL VELOCITY/ VERIFY EXACT LOCATION GPH GALLONS PER HOUR VERT VERTICAL GPM GALLONS PER MINUTE VOL VOLUME HB HOSE BIBB VR VENT RISER HD HEAD VTR VENT THROUGH ROOF HDR HEADER W WASTE/ WIDTH/ WATT HG MERCURY W/ WITH HORIZ HORIZONTAL W/0 WITHOUT HOA HAND -OFF -AUTOMATIC WAGD WASTE ANESTHESIA GAS DISPOSAL HP HORSEPOWER WC WATER CLOSET HR HOUR WCO WALL CLEANOUT HT HEIGHT/HEAT TRACE WH WALL HYDRANT/ WATER HEATER/ WATT HOUR HW DOMESTIC HOT WATER WLD WELDED HWC DOMESTIC HOT WATER CIRCULATING WM WATER METER HX HEAT EXCHANGER WO WASTE OIL HZ HERTZ WP WATERPROOF/ WEATHERPROOF IA INSTRUMENT AIR WR WASTE RISER IBC INTERNATIONAL BUILDING CODE WT WATERTIGHT WEIGHT ICW INDUSTRIAL COLD WATER WWP WORKING ATER PRESSURE ID INSIDE DIAMETER DIMENSION IE INVERT ELEVATION IN INCH INCHES WG REVISIONS INCH S WATER GAUGE INSUL INSULATE/INSULATION leo changes shall be made to the scope of work without prior approval of t ulv,jila Building Division. NOTE: R_,Visions Mill require a naw plan submittal flnrl may inrt»rla nArlitinnal elan mk iaw faac PLUMBING /PIPING LEGEND RLE COPY Permit No. 'Dr. Plan review approval is subject to errors and omissions. Approval of construLtion documents does not awhor ize the violation of any adopted code or ordinance. Recoipt of approved Field Copy and conditions is acknowledgad: By: _ -- Data: I10 City of TuiCwilS BUILDING DIVISION PLUMBING /PIPING GENERAL NOTES 1. ALL WORK SHALL CONFORM TO ALL APPLICABLE CODES AND REGULATIONS, INCLUDING, BUT NOT LIMITED TO THE 2015 IBC, 2015 UPC, 2015 WSEC & 2015 IMC WITH WASHINGTON STATE AMENDMENTS. 2. PLUMBING WORK CONSISTS OF WORK SHOWN ON DRAWINGS, DETAILS & DIAGRAMS. THE WORK INCLUDES FURNISHING, INSTALLING, SYSTEM INTEGRATION, TESTING, AND ASSURING PERFORMANCE OF THE SYSTEMS IN ACCORDANCE WITH REQUIREMENTS. THE WORK MAY INCLUDE ELECTRICAL AND ELECTRONIC COMPONENTS AS DESCRIBED IN THE CONTRACT DOCUMENTS. 3. VERIFY SYSTEM AND PERFORMANCE REQUIREMENTS TO ENSURE SYSTEM OPERATES AS DESIGNED. 4. LOCATION AND DETAIL OF ALL EQUIPMENT AND EQUIPMENT CONNECTIONS ARE APPROXIMATE. COORDINATE FINAL EQUIPMENT AND ARRANGEMENT AND INSTALL IN ACCORDANCE WITH OTHER TRADES' APPROVED SUBMITTALS AND DETAIL DRAWINGS AS APPLICABLE. 5. PROVIDE SUPPORTS FABRICATED FROM STEEL MEMBERS FOR INSTALLATION OF EQUIPMENT AS REQUIRED BY EQUIPMENT MANUFACTURER'S INSTALLATION INSTRUCTIONS OR AS SHOWN ON THE DRAWINGS. REQUIRED STRUCTURAL MEMBERS, BOLTS, AND WELDS SHALL BE IN ACCORDANCE WITH THE LATEST AMERICAN INSTITUTE OF STEEL CONSTRUCTION (AISC) MANUAL. 6. PROVIDE ANCHOR BOLTS OF THE SIZE, TYPE, AND LENGTH RECOMMENDED BY THE EQUIPMENT MANUFACTURER, AS REQUIRED BY EQUIPMENT MANUFACTURER'S INSTALLATION INSTRUCTIONS OR AS SHOWN ON THE DRAWINGS. 7. PROVIDE SUPPORTS AND SEISMIC RESTRAINTS FOR PIPES AND EQUIPMENT AS SPECIFIED OR AS SHOWN ON THE DRAWINGS. IF REQUIRED FOR INSTALLATION, PROVIDE ADDITIONAL STRUCTURAL MEMBERS BETWEEN COLUMNS, JOISTS, AND STRUCTURAL FRAMES TO MEET THE SUPPORT REACTIONS (FORCES, MOMENTS, DEFLECTIONS). STRUCTURAL MEMBERS SHALL BE DESIGNED BY A REGISTERED PROFESSIONAL ENGINEER AND INSTALLED BY G.C. WIRES FOR CEILING SYSTEM, ETC... SHALL NOT BE HUNG FROM PLUMBING EQUIPMENT OR PIPING SUPPORTS. 6. DO NOT CORE DRILL OR DRILL THROUGH BEAMS, COLUMNS, AND SHEAR WALLS UNLESS SHOWN ON THE STRUCTURAL DRAWINGS OR APPROVED BY THE STRUCTURAL ENGINEER. 9. REFER TO ARCHITECTURAL DRAWINGS FOR LOCATION OF CEILING OR SURFACE MOUNTED DEVICES. INSTALL EQUIPMENT IN CONFORMANCE WITH ARCHITECTURAL FEATURES IN THE CENTER OF CEILING TILES, IN THE CENTER OF ROOMS, OR WHERE SHOWN ON ARCHITECTURAL DRAWINGS. WHERE EQUIPMENT IS NOT SHOWN ON ARCHITECTURAL PLANS, OBTAIN DIRECTION FROM THE ARCHITECT PRIOR TO INSTALLATION. 10. COORDINATE ROOF CURB AND FLASHING REQUIREMENTS WITH ARCHITECTURAL PLANS. 11. ROOM NAMES AND NUMBERS ARE FOR REFERENCE ONLY. REFER TO ARCHITECTURAL DRAWINGS FOR PROPER NAMES AND NUMBERING SEQUENCE. 12. COORDINATE LOCATION OF PLUMBING EQUIPMENT TO PROVIDE CLEARANCES FOR REMOVAL AND SERVICE OF LIGHTING FIXTURES AND ACCESS FOR MAINTENANCE OF EQUIPMENT. 13. PLUMBING DRAWINGS DO NOT INDICATE ALL INTERFACING EQUIPMENT AND COMPONENTS. COORDINATE WITH OTHER PROJECT DRAWINGS AND DOCUMENTS FOR WORK OF OTHER TRADES. 14. MAINTAIN HEADROOM CLEARANCES PER MINIMUM OSHA STANDARDS OR AS ALLOWED BY THE AUTHCRITY HAVING JURISDICTION UNLESS NOTED OTHERWISE. 15. COORDINATE ALL SLAB PENETRATIONS AND SLEEVES WITH THE GENERAL CONTRACTOR PRIOR TO EACH CONCRETE POUR. 15. PROVIDE TRAPS WITH PROTECTION ON ALL FLOOR DRAINS, GARAGE DRAINS, AND TRENCH DRAINS, EXCEPT WHERE DRAINS FLOW INTO OIL/WATER SEPARATORS OR STORM WATER VAULTS. 17. FOR WATER HEATERS, INSTALLED IN UNCONDITIONED SPACES OR ON CONCRETE SLABS, AN INSULATED INCOMPRESSIBLE FLOOR PAD (R-10 MINIMUM) IS REQUIRED. PROVIDE 11" TALL PAN WHERE INSTALLED ABOVE A CEILING. PIPING INSULATION SHALL COMPLY WITH THE LATEST APPROVED VERSIONS OF THE INTERNATIONAL MECHANICAL AND ENERGY CODES AS DESIGNATED BY THE LOCAL JURISDICTION. 1 ALL MOTOR STARTERS NOT SHOWN IN EQUIPMENT SCHEDULES SHALL BE FURNISHED AND INSTALLED BY ELECTRICAL CONTRACTOR. MOTOR EFFICIENCIES TO MEET OR EXCEED CODE MINIMUM. WASTE AND STORM DRAIN PIPE SHALL BE SLOPED AT 4" PER FOOT UNLESS OTHERWISE NOTED. 41. ELECTRICAL METERING OF SYSTEMS AS REQUIRED BY ENERGY CODE SECTION C409 IS BY ELECTRICAL. THE ELECTRICAL DESIGN & CONTRACTOR TEAM WILL FURNISH THE NECESSARY ELECTRICAL DISTRIBUTION AND METERING COMPONENTS - SEE ELECTRICAL DRAWINGS. THE MECHANICAL CONTRACTOR WILL FURNISH A BUILDING MANAGEMENT SYSTEM CAPABLE OF COLLECTING AND STORING THE INFORMATION WITH A VISIBLE DISPLAY/NOTIFICATION READILY ACCESSIBLE TO OPERATION AND MANAGEMENT PERSONNEL AS REQUIRED. ELBOW UP SHEET NO. SHEET TITLE CURRENT REVISION D ELBOW DN LEGEND, ABBREVIATIONS, GENERAL NOTES, & SHEET INDEX - PLUMBING 1 DIRECTION OF FLOW FOUNDATION AND 1ST FLOOR PLANS & SCHEDULE - PLUMBING 1 P5.01 DIRECTION OF SLOPE DOWN 4 TO <8 >g REDUCER HOT WATER, DOMESTIC HOT WATER & RECIRC) >350 0.32-0.34 250 TEE OUTLET UP 251-350 0.29-0.32 200 TEE OUTLET DOWN - !11 UNION 141-200 0.25-0.29 125 PIPE ANCHOR 105-140 0.21-0.28 100 EXPANSION JOINT DOMESTIC COLD WATER AND HORIZONTAL RAIN LEADERS STRAINER WITH SLOWDOWN VALVE N/A 1 0.21-0.27 1 75 1 0.5 1 0.5 0.5 0.5 0.5 GATE VALVE 40-60 GLOBE VALVE 0.5 1 0.5 1.0 1.0 1.0 BALL VALVE 0.20-0.26 75 CHECK VALVE PRESSURE REDUCING VALVE ^T^ FLOW BALANCING VALVE (AUTO OR MANUAL) T&P RELIEF VALVE GAS COCK 1 LINE CLEANOUT PRESSURE GAUGE WITH GAUGE COCK THERMOMETER FLEXIBLE CONNECTION 7 PLUG OR CAP - T - WATER HAMMER ARRESTOR BUTTERFLY VALVE SOLENOID VALVE BACKFLOW PREVENTER REDUCED PRESSURE BACKFLOW PREVENTER M ER METER 7 P&T PORT EXISTING PIPING DEMO PIPING WASTE --------- VENT - - - DOMESTIC HOT WATER -RECIRCULATING - - DOMESTIC HOT WATER - DOMESTIC COLD WATER GREASE WASTE GRA! STORM DRAIN SD OVERFLOW STORM DRAIN OSD NPCW /NPHW NON -POTABLE COLD/HOT WATER DI DEIONIZED WATER WAGD WASTE ANESTHESIA GAS DISPOSAL COMPRESSED AIR CA CARBON DIOXIDE CO2 NITROGEN N2 NITROUS OXIDE NO2 OXYGEN 02 MEDICAL AIR MA MEDICAL VACUUM MV MPSM MEDIUM PRESSURE STEAM SUPPLY MPR(#) MEDIUM PRESSURE STEAM CONDENSATE RETURN LPS(#) LOW PRESSURE STEAM SUPPLY LPR(#) LOW PRESSURE STEAM CONDENSATE RETURN COND CONDENSATE ® FLOOR CLEANOUT o FLOOR DRAIN /SINK •- SBF ',^ iC PPERtJi PUMP l tEOL1:nED FOR C ROOF DRAIN OR OVERFLOW DRAT ( v4ECt1ar11Cai ® ® PLUMBING FIXTURES (TtIectrlcal ❑ Plumbing WC -1 PLUMBING FIXTURE DESIGNATION POV ® POINT OF CONNECTION c 1 of TukvAffa W"'!-! +NN''DIVISIC eRISER 1 DESIGNATION EWH-1 PLUMBING EQUIPMENT DESIGNATION 1 - DRAWING (CIRCLE NOTE) REFERENCE RLE COPY Permit No. 'Dr. Plan review approval is subject to errors and omissions. Approval of construLtion documents does not awhor ize the violation of any adopted code or ordinance. Recoipt of approved Field Copy and conditions is acknowledgad: By: _ -- Data: I10 City of TuiCwilS BUILDING DIVISION PLUMBING /PIPING GENERAL NOTES 1. ALL WORK SHALL CONFORM TO ALL APPLICABLE CODES AND REGULATIONS, INCLUDING, BUT NOT LIMITED TO THE 2015 IBC, 2015 UPC, 2015 WSEC & 2015 IMC WITH WASHINGTON STATE AMENDMENTS. 2. PLUMBING WORK CONSISTS OF WORK SHOWN ON DRAWINGS, DETAILS & DIAGRAMS. THE WORK INCLUDES FURNISHING, INSTALLING, SYSTEM INTEGRATION, TESTING, AND ASSURING PERFORMANCE OF THE SYSTEMS IN ACCORDANCE WITH REQUIREMENTS. THE WORK MAY INCLUDE ELECTRICAL AND ELECTRONIC COMPONENTS AS DESCRIBED IN THE CONTRACT DOCUMENTS. 3. VERIFY SYSTEM AND PERFORMANCE REQUIREMENTS TO ENSURE SYSTEM OPERATES AS DESIGNED. 4. LOCATION AND DETAIL OF ALL EQUIPMENT AND EQUIPMENT CONNECTIONS ARE APPROXIMATE. COORDINATE FINAL EQUIPMENT AND ARRANGEMENT AND INSTALL IN ACCORDANCE WITH OTHER TRADES' APPROVED SUBMITTALS AND DETAIL DRAWINGS AS APPLICABLE. 5. PROVIDE SUPPORTS FABRICATED FROM STEEL MEMBERS FOR INSTALLATION OF EQUIPMENT AS REQUIRED BY EQUIPMENT MANUFACTURER'S INSTALLATION INSTRUCTIONS OR AS SHOWN ON THE DRAWINGS. REQUIRED STRUCTURAL MEMBERS, BOLTS, AND WELDS SHALL BE IN ACCORDANCE WITH THE LATEST AMERICAN INSTITUTE OF STEEL CONSTRUCTION (AISC) MANUAL. 6. PROVIDE ANCHOR BOLTS OF THE SIZE, TYPE, AND LENGTH RECOMMENDED BY THE EQUIPMENT MANUFACTURER, AS REQUIRED BY EQUIPMENT MANUFACTURER'S INSTALLATION INSTRUCTIONS OR AS SHOWN ON THE DRAWINGS. 7. PROVIDE SUPPORTS AND SEISMIC RESTRAINTS FOR PIPES AND EQUIPMENT AS SPECIFIED OR AS SHOWN ON THE DRAWINGS. IF REQUIRED FOR INSTALLATION, PROVIDE ADDITIONAL STRUCTURAL MEMBERS BETWEEN COLUMNS, JOISTS, AND STRUCTURAL FRAMES TO MEET THE SUPPORT REACTIONS (FORCES, MOMENTS, DEFLECTIONS). STRUCTURAL MEMBERS SHALL BE DESIGNED BY A REGISTERED PROFESSIONAL ENGINEER AND INSTALLED BY G.C. WIRES FOR CEILING SYSTEM, ETC... SHALL NOT BE HUNG FROM PLUMBING EQUIPMENT OR PIPING SUPPORTS. 6. DO NOT CORE DRILL OR DRILL THROUGH BEAMS, COLUMNS, AND SHEAR WALLS UNLESS SHOWN ON THE STRUCTURAL DRAWINGS OR APPROVED BY THE STRUCTURAL ENGINEER. 9. REFER TO ARCHITECTURAL DRAWINGS FOR LOCATION OF CEILING OR SURFACE MOUNTED DEVICES. INSTALL EQUIPMENT IN CONFORMANCE WITH ARCHITECTURAL FEATURES IN THE CENTER OF CEILING TILES, IN THE CENTER OF ROOMS, OR WHERE SHOWN ON ARCHITECTURAL DRAWINGS. WHERE EQUIPMENT IS NOT SHOWN ON ARCHITECTURAL PLANS, OBTAIN DIRECTION FROM THE ARCHITECT PRIOR TO INSTALLATION. 10. COORDINATE ROOF CURB AND FLASHING REQUIREMENTS WITH ARCHITECTURAL PLANS. 11. ROOM NAMES AND NUMBERS ARE FOR REFERENCE ONLY. REFER TO ARCHITECTURAL DRAWINGS FOR PROPER NAMES AND NUMBERING SEQUENCE. 12. COORDINATE LOCATION OF PLUMBING EQUIPMENT TO PROVIDE CLEARANCES FOR REMOVAL AND SERVICE OF LIGHTING FIXTURES AND ACCESS FOR MAINTENANCE OF EQUIPMENT. 13. PLUMBING DRAWINGS DO NOT INDICATE ALL INTERFACING EQUIPMENT AND COMPONENTS. COORDINATE WITH OTHER PROJECT DRAWINGS AND DOCUMENTS FOR WORK OF OTHER TRADES. 14. MAINTAIN HEADROOM CLEARANCES PER MINIMUM OSHA STANDARDS OR AS ALLOWED BY THE AUTHCRITY HAVING JURISDICTION UNLESS NOTED OTHERWISE. 15. COORDINATE ALL SLAB PENETRATIONS AND SLEEVES WITH THE GENERAL CONTRACTOR PRIOR TO EACH CONCRETE POUR. 15. PROVIDE TRAPS WITH PROTECTION ON ALL FLOOR DRAINS, GARAGE DRAINS, AND TRENCH DRAINS, EXCEPT WHERE DRAINS FLOW INTO OIL/WATER SEPARATORS OR STORM WATER VAULTS. 17. FOR WATER HEATERS, INSTALLED IN UNCONDITIONED SPACES OR ON CONCRETE SLABS, AN INSULATED INCOMPRESSIBLE FLOOR PAD (R-10 MINIMUM) IS REQUIRED. PROVIDE 11" TALL PAN WHERE INSTALLED ABOVE A CEILING. PIPING INSULATION SHALL COMPLY WITH THE LATEST APPROVED VERSIONS OF THE INTERNATIONAL MECHANICAL AND ENERGY CODES AS DESIGNATED BY THE LOCAL JURISDICTION. 1 ALL MOTOR STARTERS NOT SHOWN IN EQUIPMENT SCHEDULES SHALL BE FURNISHED AND INSTALLED BY ELECTRICAL CONTRACTOR. MOTOR EFFICIENCIES TO MEET OR EXCEED CODE MINIMUM. WASTE AND STORM DRAIN PIPE SHALL BE SLOPED AT 4" PER FOOT UNLESS OTHERWISE NOTED. 41. ELECTRICAL METERING OF SYSTEMS AS REQUIRED BY ENERGY CODE SECTION C409 IS BY ELECTRICAL. THE ELECTRICAL DESIGN & CONTRACTOR TEAM WILL FURNISH THE NECESSARY ELECTRICAL DISTRIBUTION AND METERING COMPONENTS - SEE ELECTRICAL DRAWINGS. THE MECHANICAL CONTRACTOR WILL FURNISH A BUILDING MANAGEMENT SYSTEM CAPABLE OF COLLECTING AND STORING THE INFORMATION WITH A VISIBLE DISPLAY/NOTIFICATION READILY ACCESSIBLE TO OPERATION AND MANAGEMENT PERSONNEL AS REQUIRED. APN NUMBER 2715000075 LEGAL DESCRIPTION GATEWAY CORPORATE CENTER PARCEL A OF CITY OF TUKWILA SHORT PLAT NO 69 -1 -SS RECORDING NO 6904120577 SD SHORT PLAT DAF - LOT 7 OF GATEWAY CORPORATE CENTER Bryn Mawr Skyway kwila VIA 94168 S,.. -: 6 Tukivria rz v zm _ + Int .a cndi i J o ( _ _ Pr.,.51 2 VICINITY MAP NO SCALE i ` Building Today, Defining Tomorrow Hermanson Company LLP 1221 2nd Avenue North Kent, Washington 98032 Tel: (206) 575-9700 Fax: (205) 575-9800 www.hermanson.com Contractor Reg #: HERMACLO05BJ TUKWILA CORPORATE OFFICE - COFFEE KIOSK NEIGHBORHOOD FINANCIAL CENTER 12770 GATEWAY DR S TUKWILA, WA 98168 tiO D OR O wVA;s// !r n 36149 SS/CNAL .t`•a Revisions 10/05/16 DWN PERMIT CORRECTION 09/12/16 DWN ISSUE FOR PERMIT No. Date By Description MINIMUM PIPE INSULATION LAST UPDATED: 07/11/16 DRAWING INDEX SHEET NO. SHEET TITLE CURRENT REVISION P0.00 LEGEND, ABBREVIATIONS, GENERAL NOTES, & SHEET INDEX - PLUMBING 1 P2.01 FOUNDATION AND 1ST FLOOR PLANS & SCHEDULE - PLUMBING 1 P5.01 DETAIL SHEET - PLUMBING 1 4 TO <8 >g HEATING SYSTEMS (STEAM, CONDENSATE, HYDRONIC HOT WATER, DOMESTIC HOT WATER & RECIRC) >350 0.32-0.34 250 4.5 5.0 5.0 5.0 5.0 APN NUMBER 2715000075 LEGAL DESCRIPTION GATEWAY CORPORATE CENTER PARCEL A OF CITY OF TUKWILA SHORT PLAT NO 69 -1 -SS RECORDING NO 6904120577 SD SHORT PLAT DAF - LOT 7 OF GATEWAY CORPORATE CENTER Bryn Mawr Skyway kwila VIA 94168 S,.. -: 6 Tukivria rz v zm _ + Int .a cndi i J o ( _ _ Pr.,.51 2 VICINITY MAP NO SCALE i ` Building Today, Defining Tomorrow Hermanson Company LLP 1221 2nd Avenue North Kent, Washington 98032 Tel: (206) 575-9700 Fax: (205) 575-9800 www.hermanson.com Contractor Reg #: HERMACLO05BJ TUKWILA CORPORATE OFFICE - COFFEE KIOSK NEIGHBORHOOD FINANCIAL CENTER 12770 GATEWAY DR S TUKWILA, WA 98168 tiO D OR O wVA;s// !r n 36149 SS/CNAL .t`•a u➢fdUfi3x..lN;`4• , ln+ ..w. t a3i ." . 3k 4t„£nxLhiG.22 4 e Rf `.`rzssn.?S Revisions 10/05/16 DWN PERMIT CORRECTION 09/12/16 DWN ISSUE FOR PERMIT No. Date By Description MINIMUM PIPE INSULATION LAST UPDATED: 07/11/16 FLUID DESIGN INSULATION CONDUCTIVITY NOMINAL PIPE DIAMETER (INCH)_F OPERATING TEMP °F CONDUCTIVITY RANGE MEAN TEMP RATING °F <1 1 TO <1-1/2 1-1/2 TO <4 4 TO <8 >g HEATING SYSTEMS (STEAM, CONDENSATE, HYDRONIC HOT WATER, DOMESTIC HOT WATER & RECIRC) >350 0.32-0.34 250 4.5 5.0 5.0 5.0 5.0 251-350 0.29-0.32 200 3.0 4.0 4.5 4.5 4.5 201-250 0.27-0.30 150 2.5 2.5 2.5 3.0 3.0 141-200 0.25-0.29 125 1.5 1.5 2.0 2.0 2.0 105-140 0.21-0.28 100 1.0 1 1.0 1 1.5 1 1.5 1.5 DOMESTIC COLD WATER AND HORIZONTAL RAIN LEADERS TO FIRST VERTICAL RAIN LEADER (TO PREVENT CONDENSATION) N/A 1 0.21-0.27 1 75 1 0.5 1 0.5 0.5 0.5 0.5 COOLING SYSTEMS (CHILLED WATER, BRINE AND REFRIGERANT, WATERSIDE ECONOMIZER SYSTEMS)** 40-60 0.21-0.27 1 75 0.5 1 0.5 1.0 1.0 1.0 <40 0.20-0.26 75 0.5 1 1.0 1.0 1.0 1.5 114 I C: * NOT REQUIRED FOR STRAINERS, CONTROL VALVES & BALANCING VALVES ASSOCIATED WITH PIPING 1" OR LESS IN DIA. ** TYPICAL CONDENSER WATER PIPE IN NON -ECONOMIZER SYSTEMS IS NOT INSULATED AND SEE R403 FOR RESIDENTIAL INSTALLATIONS. SITE MAP REVIEWED FOR CODE COPOPLIA NCE rN 1140V O 2 26116 RECEIVED Lily or Tt uk ,,xnil• a CITYOF TUKWILA BUILDING DIVISION OCT 67 2016 PERMIT CENTER ,RECEIVED OCT 10 2016 OORRECTW TUKWILA LTR' PUBLIC WORKS Checked DTN Scale AS NOTED Drawing Number C-0195-05682 Project Number 11-15-05682 Issue Date 09/08/15 LEGEND, ABBREVIATION, GENERAL NOTES & SHEET INDEX- PLUMBING THERMOMETER EXPANSION TANK (�----------�-i CW ---i—F(}F----------�--� HW ASME RATED TEMPERATURE AND PRESSURE RELIEF VALVE. PIPE DISCHARGE FULL SIZE TO FLOOR DRAIN WATER DIELECTRIC UNION (TYP) HEATER SEISMIC STRAP AT 1/3 POINTS OF VERTICAL DIMENSION (TYP 2) F INCOMPRESSIBLE INSULATED PAD WITH MIN THERMAL RESISTANCE OF R-10 (TYP) DRAIN VALVE WITH THREADED HOSE CONNECTION FLOOR SINK FLOOR MOUNTED ELECTRIC WATER HEATER PIPING DIAGRAM Psi NOT TO SCALE (NO RECIRCULATION) EXPANSION TANK SOCHEDULE LAST UPDATED: 09/07/16 UNIT BASIS OF DIA TAG LOCATION SERVES DESIGN TYPE POSITION INCHES HEIGHT CAPACITY ACCEPTANCE MIN MAX PRESS WEIGHT INCHES GALLONS GALLONS TEMP °F TEMP °F RATING PSI LBS REMARKS ET -1 MECH ROOM EWH-1 AMTROL ST -5 BLADDER VERTICAL 8.0 12.0 2 1 50 140 125 35 1 MODEL STORAGE CAPACITY EWT LWT TYPE GALLONS OF OF 1 NON ASME RATED CONSTRUCTION ELECTRIC WATER HEATER SCHEDULE SERVES LAST UPDATED 8/22/2016 UNIT AREA BASIS OF TAG LOCATION SERVED DESIGN MODEL STORAGE CAPACITY EWT LWT TYPE GALLONS OF OF RECOVERY RATE GPH ELEC WEIGHT KW V/PH LBS REMARKS EWH-1 FLOOR EXPRESSO RHEEM PRO E201 TANK 20 50 115 12.6 2 120/1 235 1-7 GT -1 EXPRESSO 3 -COMP BIG DIPPER W -200 -IS FLOOR MT 1 POWER WIRING AND DISCONNECT (BY ELECT KICAL CUN I KAC[OR) 2 DISCONNECT AS REQUIRED BY ELECTRICAL CONTRACTOR 3 120V RECEPTACLE REQUIRED FOR PLUG IN CONNECTION BY ELECTRICAL CONTRACTOR 4 120V HARD WIRED CONNECTION BY ELECTRICAL CONTRACTOR 5 150 PSI OPERATING PRESSURE - MOUNT IN CABINET SPACE BELOW SINK. 6 DRAIN PAN TO BE PIPED TO INDIRECT CONNECTION AT FLOOR DRAIN, WALL BOX, MOP SINK, OR AIR GAP FITTING 7 PIPE RELIEF VALVE TO NEAREST FLOOR DRAIN OR HUBDRAIN AT SINK WITH INDIRECT TERMINATION GREASE TRAP SCHEDULE Last Updated: 08/22/16 UNIT TAG LOCATION SERVES BASIS OF DESIGN INSTALLATION TYPE SIZE IN INCHES MAX GPM WEIGHT LBS MATERIAL REMARKS HEIGHT WIDTH DEPTH GT -1 EXPRESSO 3 -COMP BIG DIPPER W -200 -IS FLOOR MT MOTORIZED 16" 24" 26" 20 KS -2 S.S. 1,2,3,4,5,6 HOUZER 1515-6BS 1/2 1/2 2 1.5 - 1 FD -1 FLOOR DRAIN CHROME PLATED, ROUND ADJUSTABLE STRAINER ZURN FD2210-CP - - 2 1 PLUMBING CONTRACTOR TO FIELD VERIFY INLET AND OUTLET INVERTS 2 PROVIDE FLOW RESTRICTION AT SINK DISCHARGE 3 INTERCEPTOR HOUSING WITH ACID RESISTANT INTERIOR COATING 4 CONFIRM WITH LOCAL JURISDICTION THE FINAL RINSE COMPARTMENT CONNECTION (WHETHER TO GREASE TRAP OR FLOOR SINK) PRIOR TO INSTALLATION 5 CONFIRM WITH LOCAL JURISDICTION THE QTY OF SINKS TO GREASE TRAP 6 ELECTRICAL: 115/1 AND 520 WATTS GENERAL ALTERNATE PRODUCTS ACCEPTABLE AS APPROVED BY THE ENGINEER 1 PROVIDE HOUZER STAINIER 190-9180 AND BASKET RB -3100, 1-1/2 17 GA P -TRAP CHROME PLATE, BRASSCRAFT LOOSE -KEY LAV SUPPLY KIT CHROME PLATED WITH BRAIDED FLEXIBLE HOSE. 2 PROVIDE A.R.E. COATING, ANTI -SPLASH BOTTOM DOME STRAINER, GRATING AND DEPTH AS INDICATED ON KITCHEN DRAWINGS OR AS SPECIFIED 3 DISHWASHER PROVIDED BY OTHERS. CONNECT DRAIN TO SINK TAILPIECE WITH DRAIN AND WATER SERVICE & SHUT OFF BY PLUMBING CONTRACTOR. PROVIDE WITH EASTMAN AIRGAP FITTING AT SINK 4 POLYSTYRENE OR METAL BOX WITH QUARTER TURN STOP SHUTOFF. 5 WATER SERVICE & SHUT OFF BY PLUMBING CONTRACTOR �><O I9FiNG-REQ.UII Er) _q T A L�QR-BRAT AIEt=T, L nen -- -t IrkFr-REQt E I-F-X1)15,BIASAS�EXP.� -€ T-ER-BM14I6NO�APPRQVED=EQUAL-- _161m REDUCED PRESSURE ACKFLO PREVENTERS LAST UPDATED: 08122116 UNIT TAG PLUMBING FIXTURE CONNECTION SCHEDULE BASIS OF DESIGN MODEL # OR TYPE LAST UPDATED 9/9/16 SYMBOL DESCRIPTION TYPE MANUFACTURER AND MODEL NUMBER HW CW W GPF/ V GPM REMARKS KS -1 KITCHEN SINK S.S. TRIPLE COMPARTMENT, COUNTERTOP HOUZER PGT -4322 3/4 3/4 2 1.5 - 1 KS -2 HAND SINK S.S. SINGLE COMPARTMENT, COUNTERTOP HOUZER 1515-6BS 1/2 1/2 2 1.5 - 1 FD -1 FLOOR DRAIN CHROME PLATED, ROUND ADJUSTABLE STRAINER ZURN FD2210-CP - - 2 1.5 - TPS -1 TRAP SEAL a SURE SEAL SS2009V - - - - - 6 FS -1 FLOOR SINK RECESSED FLR MT, RD. GRATE, SEEPAGE FLANGE ZURN Z1970-2 - - 3 2 - 2 FCO -1 FLOOR CLEANOUT NICKEL BRONZE TOP, ABS PLUG, ADJUSTABLE JR SMITH 40245 - - DWG - - WCO-1 WALL CLEANOUT CAST IRON TEE, NICKEL BRONZE COVER, ABS PLUG JR SMITH 4530S - - DWG - - DW -1 DISHWASHER UNDERCOUNTER, UNIT BY OTHERS - 1/2 - 1 - - 3 IM -1 ICE MAKER UNIT BY OTHERS GUY GRAY BIM -76 - 1/2 - - - 4 CM -1 COFFEE MAKER UNIT BY OTHERS I - - 1/2 1 - - - 5 GENERAL ALTERNATE PRODUCTS ACCEPTABLE AS APPROVED BY THE ENGINEER 1 PROVIDE HOUZER STAINIER 190-9180 AND BASKET RB -3100, 1-1/2 17 GA P -TRAP CHROME PLATE, BRASSCRAFT LOOSE -KEY LAV SUPPLY KIT CHROME PLATED WITH BRAIDED FLEXIBLE HOSE. 2 PROVIDE A.R.E. COATING, ANTI -SPLASH BOTTOM DOME STRAINER, GRATING AND DEPTH AS INDICATED ON KITCHEN DRAWINGS OR AS SPECIFIED 3 DISHWASHER PROVIDED BY OTHERS. CONNECT DRAIN TO SINK TAILPIECE WITH DRAIN AND WATER SERVICE & SHUT OFF BY PLUMBING CONTRACTOR. PROVIDE WITH EASTMAN AIRGAP FITTING AT SINK 4 POLYSTYRENE OR METAL BOX WITH QUARTER TURN STOP SHUTOFF. 5 WATER SERVICE & SHUT OFF BY PLUMBING CONTRACTOR �><O I9FiNG-REQ.UII Er) _q T A L�QR-BRAT AIEt=T, L nen -- -t IrkFr-REQt E I-F-X1)15,BIASAS�EXP.� -€ T-ER-BM14I6NO�APPRQVED=EQUAL-- _161m REDUCED PRESSURE ACKFLO PREVENTERS LAST UPDATED: 08122116 UNIT TAG LOCATION SERVES BASIS OF DESIGN MODEL # OR TYPE MIN GPM MAX GPM JOINT TYPE IN PSI OUT PSI REMARKS RPBP-1 CABINET EXPRESSO WATTS ES-LF009-3/4" 0.25 13 THIRD 55 40 1 RPBP-2 CABINET ICEMAKER WATTS ES-LF009-12" 1 0.25 1 1 THRD 40 23 1 1 CERTIFIED TO MEET LOW LEAD REQUIREMENTS WITH WETTED SURFACES CONTAINING LESS THAN .25% LEAD TRAP SEAL PRIMERS No form of trap that depends for its seal upon the action of movable parts shall be used. Each fixture trap shall have a liquid seal ... and shall be protected from freezing. Floor drain or similar traps directly connected to the drainage system and subject to infrequent use shall be protected with a trap seal primer. Trap seal primers shall be directly connected to the water supply and shall be accessible for maintenance. (2015 UPC 1005.0, 1006.0 & 1007.0) 2"W UP TO FD 3"W UP 2"V UP TO FS------------� FOR CONTINUATION OF _ _ 2"V UP J"CW LINES, SEE CIVIL — --- ENGINEERING DWGS 2"V UP "CW 3"W 2"W 3"W UP UP TO FS 2"V UP 4"W 3"W UP TO 2"W UP GREASE TRAP TO HAND SINK FOUNDATION PLAN —PLUMBING n; SCALE: 1/2" = 1'-0" RPBP-1 AND RPBP-2 TO DRAIN INDIRECTLY TO FLOOR SINK J"CW DN IN CABINET CO - 3"W DN PBP- FD -1 IN CABINET, PS - SEE DETAIL i2"VTR FS -1 - --- ------------I I GT -1 I -I - -- CED I FS -1 I KS -2 2"V DN i"CW SEE DETAIL �3 I P5..01; DW -1 EWH-1 ET -1 "'HW CONNECTION UNDER COUNTER, FOR DISHWASHER SEE DETAIL /, P2.01' 1ST FLOOR PLAN — PLUMBING SCALE: 1/2" = 1'-0" Building Today, Defining Tomorrow Hermanson Company LLP 1221 2nd Avenue North Kent, Washington 98032 Tel: (206) 575-9700 Fax: (205) 575-9800 www.hermanson.com Contractor Reg J: HERMACLO05BJ TUKWILA CORPORATE OFFICE - COFFEE KIOSK NEIGHBORHOOD FINANCIAL CENTER 12770 GATEWAY DR S TUKWILA, WA 98168 FOR CONTINUATION OF �o�,AODOR�,�� 4"W & 2'V LINES, SEE ��0F WAS,. CIVIL ENGINEERING DWGS 4 Q4 REVIEVVED FOR CODE COMPLIANCE APPROVED . NOV 0 2 20116 I. w ISSUE FOR PE [fife Cif 111 kvv i 1, a DUILDIi` G3 0- fV1SION RECEIVED CITY OF TUKWILA OCT U 7 2016 PERMIT CENTER 3G1A9 O �SS��NAL G�G� 10/05/16 DINN PERMIT CORRECTION 09/12/15 DINN ISSUE FOR PERMIT No. Date By Description Checked DTN Scale AS NOTED Drawing Number C-0195-05582 Project Number 11-15-05682 Issue Date 09/08/15 FOUNDATION, 1ST FLOOR PLANS, SCHEDULE & DETAILS - PLUMBING ........� I THREE COMPARTMENT SINK TO ABOVE FLOOR GREASE TRAP DETAIL P5.01 NOT TO SCALE REVIEWED FOR CODE COMPLIANCE APPROVED NOV 0 2 2016 City of Tukwila BUILDING DIVISION RECEIVED CITY OF TUKWILA OCT U 7 2016 PERMIT CENTER ISSUE FOR PERMIP14!, Building Today, Defining Tomorrow Hermanson Company LLP 1221 2nd Avenue North Kent, Washington 98032 Tel: (206) 575-9700 Fax: (205) 575-9800 www.hermanson.com Contractor Reg #: HERMACLO05BJ TUKWILA CORPORATE OFFICE - COFFEE KIOSK NEIGHBORHOOD FINANCIAL CENTER 12770 GATEWAY DR S TUKWILA, WA 98168 M 36149 1-t6l �A'JUn,�iI3J,�5i: so,.,8 rEt2'man "Y a)gcSifk4 ?Ila+'SLiPi�Si� Revisions J&10/06/16 DWN PERMIT CORRECTION 09/12/16 DWN ISSUE FOR PERMIT No. Date By Description Design Team Design DWN Drawn FVP Checked DTN Scale AS NOTED Drawing Number C-0195-05682 Project Number 11-15-05582 Issue Date 09/08/16 DETAIL SHEET - PLUMBING PLUMBING /PIPING ABBREVIATIONS A AI%COMPRESSED AIR INV INVERT ABS ACRRYLONITRITE BUTADIENE STYRENE IRW IRRIGATION WATER ABV ABOVE IW INDIRECT WASTE AC AIR COMPRESSOR KWH KILOWATT HOUR AD ACCESS DOOR AREA DRAIN/AIR DRYER KEC KITCHEN EQUIPMENT CONTRACTOR ADD/ADD'L ADDITION/ADDIIONAL LAV LAVATORY ADJ ADJACENT/ADJUST/ADJUSTABLE/ADJUSTMENT LB/LBS POUND/POUNDS AFF ABOVE FINISHED FLOOR LBS/HR POUNDS PER HOUR AFG ABOVE FINISHED GRADE LPG LIQUID PROPANE GAS AP ACCESS PANEL LPS LOW PRESSURE STEAM ARCH ARCHITECT LWT LEAVING WATER TEMPERATURE ASME AMERICAN SOCIETY OF MECHANICAL ENGINEERS MAX MAXIMUM ATM ATMOSPHERE ATMOSPHERIC MSH 1000 BRITISH THERMAL UNITS PER HOUR BHP BRAKE HORS POWER/BOILER HORSEPOWER MCA MINIMUM CIRCUIT AMPACITY BLDG BUILDING MECH MECHANICAL BOP BOTTOM OF PIPE MFR MANUFACTURER BOT BOTTOM MIN MINIMUM MINUTE BS BLACK STEEL MISC MISCEL NEOUS BTU BRITISH THERMAL UNIT MM MILLIMETERS BTUH BRITISH THERMAL UNITS PER HOUR MPS MEDIUM PRESSURE STEAM COND CONDENSATE MTD MOUNTED CA COMPRESSED AIR N NITROGEN C TO C CENTER TO CENTER NA NOT APPLICABLE CAP CAPACITY/END CAP NC NORMALLY CLOSED/ NOISE CRITERIA CB CATCH BASIN NG NATURAL GAS CENT CENTRIFUGE/CENTRIFUGAL NIC NOT IN CONTRACT CFF CAP FOR FUTURE NO NORMALLY OPEN/ NUMBER CFM CUBIC FEET PER MINUTE NO2 NITROUS OXIDE CI CAST IRON NOM NOMINAL CLG CEILING NP NON -POTABLE CMU CONCRETE MASONRY UNIT NTS NOT TO SCALE CO CLEANOUT/COMPANY/CARBON MONOXIDE 02 OXYGEN CO2 CARBON DIOXIDE OC ON CENTER COL COLUMN OD OUTSIDE DIAMETER/DIMENSION/ OVERFLOW DRAIN CONC CONCRETE ODP OPEN DRIPPROOF COND CONDENSATE ORD OVERFLOW ROOF DRAIN CONN CONNECT CONNECTED CONNECTION OVHD OVERHEAD CONT CONT INU US/CONTIN ATION PD PRESSURE DROP/ PIT DRAIN/ PUMP DISCHARGE CONTR CONTRACTOR PERF PERFORATED COORD COORDINATE PH PHASE CPVC CHLORINATED POLYVINYL CHLORIDE PLBG PLUMBING CT COOLING TOWER POC POINT OF CONNECTION CU CUBIC/COPPER/CONDENSING UNIT PRESS PRESSURE CW DOMESTIC COLD WATER PRV PRESSURE REDUCING VALVE DCVA DOUBLE CHECK VALVE ASSEMBLY PS PRESSURE SWITCH DDC DIRECT DIGITAL CONTROL PSF POUNDS PER SQUARE FOOT DEG DEGREE/DEGREES PSI POUNDS PER SQUARE INCH DI DEIONIZED WATER PSIG POUNDS PER SQUARE INCH GAUGE DIA DIAMETER PVC POLYVINYL CHLORIDE DIFF DIFFERENTIAL/DIFFERENCE/DELTA QTY QUANTITY DISCH DISCHARGE R RISER(RETURN DN DOWN RCVR RECEIVR DOM DOMESTIC RD ROOF DRAIN/ REFRIGERANT DISCHARGE DR DRAIN RECIRC RECIRCULATING/ RECIRCULATE DS DOWNSPOUT RED REDUCE/ REDUCING DWG DRAWING REF REFERENCE DWV DRAIN, WASTE AND VENT REG REGULATOR _ EA EACH RL RAIN LEADER/ REFRIGERANT LIQUID EFF EFFICIENCY RPBP REDUCED PRESSURE BACKFLOW PREVENTER EL ELEVATION RPM REVOLUTIONS PER MINUTE ELEC/ELECT ELECTRICAL/ELECTRIC RS REFRIGERANT SUCTION EMERR EMERGENCY RV RELIEF VALVE ENT ENTERING RVD RELIEF VALVE DISCHARGE EQUIP EQUIPMENT S SOIL/ SUPPLY ERW ELECTRIC RESISTANCE WELDED SAN SANITARY ES EMERGENCY SHOWER SAT SATURATION ET EXPANSION TANK SD STORM DRAIN EWC ELECTRIC WATER COOLER/ S -C SEATTLE N_ CODE EVAPORATIVE WATER COOLER SECT SECTION EWT ENTERING WATER TEMPERATURE SO SCREENED OPENING EXIST EXISTING SOL SOLENOID EXP EXPANSION EXPOSED/EXPLOSION PROOF SOLV SOLENOID VALVE EXT EXTERNAL EXTERIOR SP STATIC PRESSURE/ SPRINKLER F FAHRENH IT/FEED/FILTER SPEC SPECIFICATION FA FACE AREA/FIRE ALARM SQ SQUARE FCO FLOOR CLEAN OUT SQ FT SQUARE FEET FD FLOOR DRAIN SS SANITARY SEWER FDN FOUNDATION STRUC STRUCTURAL FF FINISH FLOOR SUCT SUCTION FFD FUNNEL FLOOR DRAIN TBD TO BE DETERMINED FIC FURNISHED AND INSTALLED BY CONTRACTOR TD TEMPERATURE DIFFERENTIAL FIO FURNISHED AND INSTALLED BY OWNER TEMP TEMPERATURE TEMPORARY FLEX FLEXIBLE THERM THERMOMETER FLR FLOOR TOP TOP OF PIPE FDIC FURNISHED BY OWNER INSTALLED BY OTHERS TP TRAP PRIMER FP FREEZE PROOF/FIRE PROTECTION TPS TRAP SEAL FPM FEET PER MINUTE TYP TYPICAL FPS FEET PER SECOND UG UNDERGROUND FPWH FREEZE PROOF WALL HYDRANT UNO UNLESS NOTED OTHERWISE FS FLOOR SINK, FLOW SWITCH UPC UNIFORM PLUMBING CODE FT FOOT/FEET UR URINAL GA/GAL GALLON UTIL UTILITY GALV GALVANIZED V VENT/ VOLT GD GARAGE DRAIN/GARBAGE DISPOSAL VA VALVE/ VOLT AMPERE/ VACUUM AIR GC GENERAL CONTRACTOR VAC VOLTS ALTERNATING CURRENT/ VACUUM GEN GENERAL VB VACUUM BREAKER GND GROUND VEL VELOCITY/ VERIFY EXACT LOCATION GPH GALLONS PER HOUR VERT VERTICAL GPM GALLONS PER MINUTE VOL VOLUME HB HOSE BIBB VR VENT RISER HD HEAD VTR VENT THROUGH ROOF HDR HEADER W WASTE/ WIDTH/ WATT HG MERCURY W/ WITH HORIZ HORIZONTAL W/0 WITHOUT HOA HAND -OFF -AUTOMATIC WAGD WASTE ANESTHESIA GAS DISPOSAL HP HORSEPOWER WC WATER CLOSET HR HOUR WCO WALL CLEANOUT HT HEIGHT/HEAT TRACE WH WALL HYDRANT/ WATER HEATER/ WATT HOUR HW DOMESTIC HOT WATER WLD WELDED HWC DOMESTIC HOT WATER CIRCULATING WM WATER METER HX HEAT EXCHANGER WO WASTE OIL HZ HERTZ WP WATERPROOF/ WEATHERPROOF IA INSTRUMENT AIR WR WASTE RISER IBC INTERNATIONAL BUILDING CODE WT WATERTIGHT WEIGHT ICW INDUSTRIAL COLD WATER WWP WORKING ATER PRESSURE ID INSIDE DIAMETER DIMENSION IE INVERT ELEVATION IN INCH INCHES WG REVISIONS INCH S WATER GAUGE INSUL INSULATE/INSULATION leo changes shall be made to the scope of work without prior approval of t ulv,jila Building Division. NOTE: R_,Visions Mill require a naw plan submittal flnrl may inrt»rla nArlitinnal elan mk iaw faac PLUMBING /PIPING LEGEND RLE COPY Permit No. 'Dr. Plan review approval is subject to errors and omissions. Approval of construLtion documents does not awhor ize the violation of any adopted code or ordinance. Recoipt of approved Field Copy and conditions is acknowledgad: By: _ -- Data: I10 City of TuiCwilS BUILDING DIVISION PLUMBING /PIPING GENERAL NOTES 1. ALL WORK SHALL CONFORM TO ALL APPLICABLE CODES AND REGULATIONS, INCLUDING, BUT NOT LIMITED TO THE 2015 IBC, 2015 UPC, 2015 WSEC & 2015 IMC WITH WASHINGTON STATE AMENDMENTS. 2. PLUMBING WORK CONSISTS OF WORK SHOWN ON DRAWINGS, DETAILS & DIAGRAMS. THE WORK INCLUDES FURNISHING, INSTALLING, SYSTEM INTEGRATION, TESTING, AND ASSURING PERFORMANCE OF THE SYSTEMS IN ACCORDANCE WITH REQUIREMENTS. THE WORK MAY INCLUDE ELECTRICAL AND ELECTRONIC COMPONENTS AS DESCRIBED IN THE CONTRACT DOCUMENTS. 3. VERIFY SYSTEM AND PERFORMANCE REQUIREMENTS TO ENSURE SYSTEM OPERATES AS DESIGNED. 4. LOCATION AND DETAIL OF ALL EQUIPMENT AND EQUIPMENT CONNECTIONS ARE APPROXIMATE. COORDINATE FINAL EQUIPMENT AND ARRANGEMENT AND INSTALL IN ACCORDANCE WITH OTHER TRADES' APPROVED SUBMITTALS AND DETAIL DRAWINGS AS APPLICABLE. 5. PROVIDE SUPPORTS FABRICATED FROM STEEL MEMBERS FOR INSTALLATION OF EQUIPMENT AS REQUIRED BY EQUIPMENT MANUFACTURER'S INSTALLATION INSTRUCTIONS OR AS SHOWN ON THE DRAWINGS. REQUIRED STRUCTURAL MEMBERS, BOLTS, AND WELDS SHALL BE IN ACCORDANCE WITH THE LATEST AMERICAN INSTITUTE OF STEEL CONSTRUCTION (AISC) MANUAL. 6. PROVIDE ANCHOR BOLTS OF THE SIZE, TYPE, AND LENGTH RECOMMENDED BY THE EQUIPMENT MANUFACTURER, AS REQUIRED BY EQUIPMENT MANUFACTURER'S INSTALLATION INSTRUCTIONS OR AS SHOWN ON THE DRAWINGS. 7. PROVIDE SUPPORTS AND SEISMIC RESTRAINTS FOR PIPES AND EQUIPMENT AS SPECIFIED OR AS SHOWN ON THE DRAWINGS. IF REQUIRED FOR INSTALLATION, PROVIDE ADDITIONAL STRUCTURAL MEMBERS BETWEEN COLUMNS, JOISTS, AND STRUCTURAL FRAMES TO MEET THE SUPPORT REACTIONS (FORCES, MOMENTS, DEFLECTIONS). STRUCTURAL MEMBERS SHALL BE DESIGNED BY A REGISTERED PROFESSIONAL ENGINEER AND INSTALLED BY G.C. WIRES FOR CEILING SYSTEM, ETC... SHALL NOT BE HUNG FROM PLUMBING EQUIPMENT OR PIPING SUPPORTS. 6. DO NOT CORE DRILL OR DRILL THROUGH BEAMS, COLUMNS, AND SHEAR WALLS UNLESS SHOWN ON THE STRUCTURAL DRAWINGS OR APPROVED BY THE STRUCTURAL ENGINEER. 9. REFER TO ARCHITECTURAL DRAWINGS FOR LOCATION OF CEILING OR SURFACE MOUNTED DEVICES. INSTALL EQUIPMENT IN CONFORMANCE WITH ARCHITECTURAL FEATURES IN THE CENTER OF CEILING TILES, IN THE CENTER OF ROOMS, OR WHERE SHOWN ON ARCHITECTURAL DRAWINGS. WHERE EQUIPMENT IS NOT SHOWN ON ARCHITECTURAL PLANS, OBTAIN DIRECTION FROM THE ARCHITECT PRIOR TO INSTALLATION. 10. COORDINATE ROOF CURB AND FLASHING REQUIREMENTS WITH ARCHITECTURAL PLANS. 11. ROOM NAMES AND NUMBERS ARE FOR REFERENCE ONLY. REFER TO ARCHITECTURAL DRAWINGS FOR PROPER NAMES AND NUMBERING SEQUENCE. 12. COORDINATE LOCATION OF PLUMBING EQUIPMENT TO PROVIDE CLEARANCES FOR REMOVAL AND SERVICE OF LIGHTING FIXTURES AND ACCESS FOR MAINTENANCE OF EQUIPMENT. 13. PLUMBING DRAWINGS DO NOT INDICATE ALL INTERFACING EQUIPMENT AND COMPONENTS. COORDINATE WITH OTHER PROJECT DRAWINGS AND DOCUMENTS FOR WORK OF OTHER TRADES. 14. MAINTAIN HEADROOM CLEARANCES PER MINIMUM OSHA STANDARDS OR AS ALLOWED BY THE AUTHCRITY HAVING JURISDICTION UNLESS NOTED OTHERWISE. 15. COORDINATE ALL SLAB PENETRATIONS AND SLEEVES WITH THE GENERAL CONTRACTOR PRIOR TO EACH CONCRETE POUR. 15. PROVIDE TRAPS WITH PROTECTION ON ALL FLOOR DRAINS, GARAGE DRAINS, AND TRENCH DRAINS, EXCEPT WHERE DRAINS FLOW INTO OIL/WATER SEPARATORS OR STORM WATER VAULTS. 17. FOR WATER HEATERS, INSTALLED IN UNCONDITIONED SPACES OR ON CONCRETE SLABS, AN INSULATED INCOMPRESSIBLE FLOOR PAD (R-10 MINIMUM) IS REQUIRED. PROVIDE 11" TALL PAN WHERE INSTALLED ABOVE A CEILING. PIPING INSULATION SHALL COMPLY WITH THE LATEST APPROVED VERSIONS OF THE INTERNATIONAL MECHANICAL AND ENERGY CODES AS DESIGNATED BY THE LOCAL JURISDICTION. 1 ALL MOTOR STARTERS NOT SHOWN IN EQUIPMENT SCHEDULES SHALL BE FURNISHED AND INSTALLED BY ELECTRICAL CONTRACTOR. MOTOR EFFICIENCIES TO MEET OR EXCEED CODE MINIMUM. WASTE AND STORM DRAIN PIPE SHALL BE SLOPED AT 4" PER FOOT UNLESS OTHERWISE NOTED. 41. ELECTRICAL METERING OF SYSTEMS AS REQUIRED BY ENERGY CODE SECTION C409 IS BY ELECTRICAL. THE ELECTRICAL DESIGN & CONTRACTOR TEAM WILL FURNISH THE NECESSARY ELECTRICAL DISTRIBUTION AND METERING COMPONENTS - SEE ELECTRICAL DRAWINGS. THE MECHANICAL CONTRACTOR WILL FURNISH A BUILDING MANAGEMENT SYSTEM CAPABLE OF COLLECTING AND STORING THE INFORMATION WITH A VISIBLE DISPLAY/NOTIFICATION READILY ACCESSIBLE TO OPERATION AND MANAGEMENT PERSONNEL AS REQUIRED. ELBOW UP SHEET NO. SHEET TITLE CURRENT REVISION D ELBOW DN LEGEND, ABBREVIATIONS, GENERAL NOTES, & SHEET INDEX - PLUMBING 1 DIRECTION OF FLOW FOUNDATION AND 1ST FLOOR PLANS & SCHEDULE - PLUMBING 1 P5.01 DIRECTION OF SLOPE DOWN 4 TO <8 >g REDUCER HOT WATER, DOMESTIC HOT WATER & RECIRC) >350 0.32-0.34 250 TEE OUTLET UP 251-350 0.29-0.32 200 TEE OUTLET DOWN - !11 UNION 141-200 0.25-0.29 125 PIPE ANCHOR 105-140 0.21-0.28 100 EXPANSION JOINT DOMESTIC COLD WATER AND HORIZONTAL RAIN LEADERS STRAINER WITH SLOWDOWN VALVE N/A 1 0.21-0.27 1 75 1 0.5 1 0.5 0.5 0.5 0.5 GATE VALVE 40-60 GLOBE VALVE 0.5 1 0.5 1.0 1.0 1.0 BALL VALVE 0.20-0.26 75 CHECK VALVE PRESSURE REDUCING VALVE ^T^ FLOW BALANCING VALVE (AUTO OR MANUAL) T&P RELIEF VALVE GAS COCK 1 LINE CLEANOUT PRESSURE GAUGE WITH GAUGE COCK THERMOMETER FLEXIBLE CONNECTION 7 PLUG OR CAP - T - WATER HAMMER ARRESTOR BUTTERFLY VALVE SOLENOID VALVE BACKFLOW PREVENTER REDUCED PRESSURE BACKFLOW PREVENTER M ER METER 7 P&T PORT EXISTING PIPING DEMO PIPING WASTE --------- VENT - - - DOMESTIC HOT WATER -RECIRCULATING - - DOMESTIC HOT WATER - DOMESTIC COLD WATER GREASE WASTE GRA! STORM DRAIN SD OVERFLOW STORM DRAIN OSD NPCW /NPHW NON -POTABLE COLD/HOT WATER DI DEIONIZED WATER WAGD WASTE ANESTHESIA GAS DISPOSAL COMPRESSED AIR CA CARBON DIOXIDE CO2 NITROGEN N2 NITROUS OXIDE NO2 OXYGEN 02 MEDICAL AIR MA MEDICAL VACUUM MV MPSM MEDIUM PRESSURE STEAM SUPPLY MPR(#) MEDIUM PRESSURE STEAM CONDENSATE RETURN LPS(#) LOW PRESSURE STEAM SUPPLY LPR(#) LOW PRESSURE STEAM CONDENSATE RETURN COND CONDENSATE ® FLOOR CLEANOUT o FLOOR DRAIN /SINK •- SBF ',^ iC PPERtJi PUMP l tEOL1:nED FOR C ROOF DRAIN OR OVERFLOW DRAT ( v4ECt1ar11Cai ® ® PLUMBING FIXTURES (TtIectrlcal ❑ Plumbing WC -1 PLUMBING FIXTURE DESIGNATION POV ® POINT OF CONNECTION c 1 of TukvAffa W"'!-! +NN''DIVISIC eRISER 1 DESIGNATION EWH-1 PLUMBING EQUIPMENT DESIGNATION 1 - DRAWING (CIRCLE NOTE) REFERENCE RLE COPY Permit No. 'Dr. Plan review approval is subject to errors and omissions. Approval of construLtion documents does not awhor ize the violation of any adopted code or ordinance. Recoipt of approved Field Copy and conditions is acknowledgad: By: _ -- Data: I10 City of TuiCwilS BUILDING DIVISION PLUMBING /PIPING GENERAL NOTES 1. ALL WORK SHALL CONFORM TO ALL APPLICABLE CODES AND REGULATIONS, INCLUDING, BUT NOT LIMITED TO THE 2015 IBC, 2015 UPC, 2015 WSEC & 2015 IMC WITH WASHINGTON STATE AMENDMENTS. 2. PLUMBING WORK CONSISTS OF WORK SHOWN ON DRAWINGS, DETAILS & DIAGRAMS. THE WORK INCLUDES FURNISHING, INSTALLING, SYSTEM INTEGRATION, TESTING, AND ASSURING PERFORMANCE OF THE SYSTEMS IN ACCORDANCE WITH REQUIREMENTS. THE WORK MAY INCLUDE ELECTRICAL AND ELECTRONIC COMPONENTS AS DESCRIBED IN THE CONTRACT DOCUMENTS. 3. VERIFY SYSTEM AND PERFORMANCE REQUIREMENTS TO ENSURE SYSTEM OPERATES AS DESIGNED. 4. LOCATION AND DETAIL OF ALL EQUIPMENT AND EQUIPMENT CONNECTIONS ARE APPROXIMATE. COORDINATE FINAL EQUIPMENT AND ARRANGEMENT AND INSTALL IN ACCORDANCE WITH OTHER TRADES' APPROVED SUBMITTALS AND DETAIL DRAWINGS AS APPLICABLE. 5. PROVIDE SUPPORTS FABRICATED FROM STEEL MEMBERS FOR INSTALLATION OF EQUIPMENT AS REQUIRED BY EQUIPMENT MANUFACTURER'S INSTALLATION INSTRUCTIONS OR AS SHOWN ON THE DRAWINGS. REQUIRED STRUCTURAL MEMBERS, BOLTS, AND WELDS SHALL BE IN ACCORDANCE WITH THE LATEST AMERICAN INSTITUTE OF STEEL CONSTRUCTION (AISC) MANUAL. 6. PROVIDE ANCHOR BOLTS OF THE SIZE, TYPE, AND LENGTH RECOMMENDED BY THE EQUIPMENT MANUFACTURER, AS REQUIRED BY EQUIPMENT MANUFACTURER'S INSTALLATION INSTRUCTIONS OR AS SHOWN ON THE DRAWINGS. 7. PROVIDE SUPPORTS AND SEISMIC RESTRAINTS FOR PIPES AND EQUIPMENT AS SPECIFIED OR AS SHOWN ON THE DRAWINGS. IF REQUIRED FOR INSTALLATION, PROVIDE ADDITIONAL STRUCTURAL MEMBERS BETWEEN COLUMNS, JOISTS, AND STRUCTURAL FRAMES TO MEET THE SUPPORT REACTIONS (FORCES, MOMENTS, DEFLECTIONS). STRUCTURAL MEMBERS SHALL BE DESIGNED BY A REGISTERED PROFESSIONAL ENGINEER AND INSTALLED BY G.C. WIRES FOR CEILING SYSTEM, ETC... SHALL NOT BE HUNG FROM PLUMBING EQUIPMENT OR PIPING SUPPORTS. 6. DO NOT CORE DRILL OR DRILL THROUGH BEAMS, COLUMNS, AND SHEAR WALLS UNLESS SHOWN ON THE STRUCTURAL DRAWINGS OR APPROVED BY THE STRUCTURAL ENGINEER. 9. REFER TO ARCHITECTURAL DRAWINGS FOR LOCATION OF CEILING OR SURFACE MOUNTED DEVICES. INSTALL EQUIPMENT IN CONFORMANCE WITH ARCHITECTURAL FEATURES IN THE CENTER OF CEILING TILES, IN THE CENTER OF ROOMS, OR WHERE SHOWN ON ARCHITECTURAL DRAWINGS. WHERE EQUIPMENT IS NOT SHOWN ON ARCHITECTURAL PLANS, OBTAIN DIRECTION FROM THE ARCHITECT PRIOR TO INSTALLATION. 10. COORDINATE ROOF CURB AND FLASHING REQUIREMENTS WITH ARCHITECTURAL PLANS. 11. ROOM NAMES AND NUMBERS ARE FOR REFERENCE ONLY. REFER TO ARCHITECTURAL DRAWINGS FOR PROPER NAMES AND NUMBERING SEQUENCE. 12. COORDINATE LOCATION OF PLUMBING EQUIPMENT TO PROVIDE CLEARANCES FOR REMOVAL AND SERVICE OF LIGHTING FIXTURES AND ACCESS FOR MAINTENANCE OF EQUIPMENT. 13. PLUMBING DRAWINGS DO NOT INDICATE ALL INTERFACING EQUIPMENT AND COMPONENTS. COORDINATE WITH OTHER PROJECT DRAWINGS AND DOCUMENTS FOR WORK OF OTHER TRADES. 14. MAINTAIN HEADROOM CLEARANCES PER MINIMUM OSHA STANDARDS OR AS ALLOWED BY THE AUTHCRITY HAVING JURISDICTION UNLESS NOTED OTHERWISE. 15. COORDINATE ALL SLAB PENETRATIONS AND SLEEVES WITH THE GENERAL CONTRACTOR PRIOR TO EACH CONCRETE POUR. 15. PROVIDE TRAPS WITH PROTECTION ON ALL FLOOR DRAINS, GARAGE DRAINS, AND TRENCH DRAINS, EXCEPT WHERE DRAINS FLOW INTO OIL/WATER SEPARATORS OR STORM WATER VAULTS. 17. FOR WATER HEATERS, INSTALLED IN UNCONDITIONED SPACES OR ON CONCRETE SLABS, AN INSULATED INCOMPRESSIBLE FLOOR PAD (R-10 MINIMUM) IS REQUIRED. PROVIDE 11" TALL PAN WHERE INSTALLED ABOVE A CEILING. PIPING INSULATION SHALL COMPLY WITH THE LATEST APPROVED VERSIONS OF THE INTERNATIONAL MECHANICAL AND ENERGY CODES AS DESIGNATED BY THE LOCAL JURISDICTION. 1 ALL MOTOR STARTERS NOT SHOWN IN EQUIPMENT SCHEDULES SHALL BE FURNISHED AND INSTALLED BY ELECTRICAL CONTRACTOR. MOTOR EFFICIENCIES TO MEET OR EXCEED CODE MINIMUM. WASTE AND STORM DRAIN PIPE SHALL BE SLOPED AT 4" PER FOOT UNLESS OTHERWISE NOTED. 41. ELECTRICAL METERING OF SYSTEMS AS REQUIRED BY ENERGY CODE SECTION C409 IS BY ELECTRICAL. THE ELECTRICAL DESIGN & CONTRACTOR TEAM WILL FURNISH THE NECESSARY ELECTRICAL DISTRIBUTION AND METERING COMPONENTS - SEE ELECTRICAL DRAWINGS. THE MECHANICAL CONTRACTOR WILL FURNISH A BUILDING MANAGEMENT SYSTEM CAPABLE OF COLLECTING AND STORING THE INFORMATION WITH A VISIBLE DISPLAY/NOTIFICATION READILY ACCESSIBLE TO OPERATION AND MANAGEMENT PERSONNEL AS REQUIRED. APN NUMBER 2715000075 LEGAL DESCRIPTION GATEWAY CORPORATE CENTER PARCEL A OF CITY OF TUKWILA SHORT PLAT NO 69 -1 -SS RECORDING NO 6904120577 SD SHORT PLAT DAF - LOT 7 OF GATEWAY CORPORATE CENTER Bryn Mawr Skyway kwila VIA 94168 S,.. -: 6 Tukivria rz v zm _ + Int .a cndi i J o ( _ _ Pr.,.51 2 VICINITY MAP NO SCALE i ` Building Today, Defining Tomorrow Hermanson Company LLP 1221 2nd Avenue North Kent, Washington 98032 Tel: (206) 575-9700 Fax: (205) 575-9800 www.hermanson.com Contractor Reg #: HERMACLO05BJ TUKWILA CORPORATE OFFICE - COFFEE KIOSK NEIGHBORHOOD FINANCIAL CENTER 12770 GATEWAY DR S TUKWILA, WA 98168 tiO D OR O wVA;s// !r n 36149 SS/CNAL .t`•a Revisions 10/05/16 DWN PERMIT CORRECTION 09/12/16 DWN ISSUE FOR PERMIT No. Date By Description MINIMUM PIPE INSULATION LAST UPDATED: 07/11/16 DRAWING INDEX SHEET NO. SHEET TITLE CURRENT REVISION P0.00 LEGEND, ABBREVIATIONS, GENERAL NOTES, & SHEET INDEX - PLUMBING 1 P2.01 FOUNDATION AND 1ST FLOOR PLANS & SCHEDULE - PLUMBING 1 P5.01 DETAIL SHEET - PLUMBING 1 4 TO <8 >g HEATING SYSTEMS (STEAM, CONDENSATE, HYDRONIC HOT WATER, DOMESTIC HOT WATER & RECIRC) >350 0.32-0.34 250 4.5 5.0 5.0 5.0 5.0 APN NUMBER 2715000075 LEGAL DESCRIPTION GATEWAY CORPORATE CENTER PARCEL A OF CITY OF TUKWILA SHORT PLAT NO 69 -1 -SS RECORDING NO 6904120577 SD SHORT PLAT DAF - LOT 7 OF GATEWAY CORPORATE CENTER Bryn Mawr Skyway kwila VIA 94168 S,.. -: 6 Tukivria rz v zm _ + Int .a cndi i J o ( _ _ Pr.,.51 2 VICINITY MAP NO SCALE i ` Building Today, Defining Tomorrow Hermanson Company LLP 1221 2nd Avenue North Kent, Washington 98032 Tel: (206) 575-9700 Fax: (205) 575-9800 www.hermanson.com Contractor Reg #: HERMACLO05BJ TUKWILA CORPORATE OFFICE - COFFEE KIOSK NEIGHBORHOOD FINANCIAL CENTER 12770 GATEWAY DR S TUKWILA, WA 98168 tiO D OR O wVA;s// !r n 36149 SS/CNAL .t`•a u➢fdUfi3x..lN;`4• , ln+ ..w. t a3i ." . 3k 4t„£nxLhiG.22 4 e Rf `.`rzssn.?S Revisions 10/05/16 DWN PERMIT CORRECTION 09/12/16 DWN ISSUE FOR PERMIT No. Date By Description MINIMUM PIPE INSULATION LAST UPDATED: 07/11/16 FLUID DESIGN INSULATION CONDUCTIVITY NOMINAL PIPE DIAMETER (INCH)_F OPERATING TEMP °F CONDUCTIVITY RANGE MEAN TEMP RATING °F <1 1 TO <1-1/2 1-1/2 TO <4 4 TO <8 >g HEATING SYSTEMS (STEAM, CONDENSATE, HYDRONIC HOT WATER, DOMESTIC HOT WATER & RECIRC) >350 0.32-0.34 250 4.5 5.0 5.0 5.0 5.0 251-350 0.29-0.32 200 3.0 4.0 4.5 4.5 4.5 201-250 0.27-0.30 150 2.5 2.5 2.5 3.0 3.0 141-200 0.25-0.29 125 1.5 1.5 2.0 2.0 2.0 105-140 0.21-0.28 100 1.0 1 1.0 1 1.5 1 1.5 1.5 DOMESTIC COLD WATER AND HORIZONTAL RAIN LEADERS TO FIRST VERTICAL RAIN LEADER (TO PREVENT CONDENSATION) N/A 1 0.21-0.27 1 75 1 0.5 1 0.5 0.5 0.5 0.5 COOLING SYSTEMS (CHILLED WATER, BRINE AND REFRIGERANT, WATERSIDE ECONOMIZER SYSTEMS)** 40-60 0.21-0.27 1 75 0.5 1 0.5 1.0 1.0 1.0 <40 0.20-0.26 75 0.5 1 1.0 1.0 1.0 1.5 114 I C: * NOT REQUIRED FOR STRAINERS, CONTROL VALVES & BALANCING VALVES ASSOCIATED WITH PIPING 1" OR LESS IN DIA. ** TYPICAL CONDENSER WATER PIPE IN NON -ECONOMIZER SYSTEMS IS NOT INSULATED AND SEE R403 FOR RESIDENTIAL INSTALLATIONS. SITE MAP REVIEWED FOR CODE COPOPLIA NCE rN 1140V O 2 26116 RECEIVED Lily or Tt uk ,,xnil• a CITYOF TUKWILA BUILDING DIVISION OCT 67 2016 PERMIT CENTER ,RECEIVED OCT 10 2016 OORRECTW TUKWILA LTR' PUBLIC WORKS Checked DTN Scale AS NOTED Drawing Number C-0195-05682 Project Number 11-15-05682 Issue Date 09/08/15 LEGEND, ABBREVIATION, GENERAL NOTES & SHEET INDEX- PLUMBING THERMOMETER EXPANSION TANK (�----------�-i CW ---i—F(}F----------�--� HW ASME RATED TEMPERATURE AND PRESSURE RELIEF VALVE. PIPE DISCHARGE FULL SIZE TO FLOOR DRAIN WATER DIELECTRIC UNION (TYP) HEATER SEISMIC STRAP AT 1/3 POINTS OF VERTICAL DIMENSION (TYP 2) F INCOMPRESSIBLE INSULATED PAD WITH MIN THERMAL RESISTANCE OF R-10 (TYP) DRAIN VALVE WITH THREADED HOSE CONNECTION FLOOR SINK FLOOR MOUNTED ELECTRIC WATER HEATER PIPING DIAGRAM Psi NOT TO SCALE (NO RECIRCULATION) EXPANSION TANK SOCHEDULE LAST UPDATED: 09/07/16 UNIT BASIS OF DIA TAG LOCATION SERVES DESIGN TYPE POSITION INCHES HEIGHT CAPACITY ACCEPTANCE MIN MAX PRESS WEIGHT INCHES GALLONS GALLONS TEMP °F TEMP °F RATING PSI LBS REMARKS ET -1 MECH ROOM EWH-1 AMTROL ST -5 BLADDER VERTICAL 8.0 12.0 2 1 50 140 125 35 1 MODEL STORAGE CAPACITY EWT LWT TYPE GALLONS OF OF 1 NON ASME RATED CONSTRUCTION ELECTRIC WATER HEATER SCHEDULE SERVES LAST UPDATED 8/22/2016 UNIT AREA BASIS OF TAG LOCATION SERVED DESIGN MODEL STORAGE CAPACITY EWT LWT TYPE GALLONS OF OF RECOVERY RATE GPH ELEC WEIGHT KW V/PH LBS REMARKS EWH-1 FLOOR EXPRESSO RHEEM PRO E201 TANK 20 50 115 12.6 2 120/1 235 1-7 GT -1 EXPRESSO 3 -COMP BIG DIPPER W -200 -IS FLOOR MT 1 POWER WIRING AND DISCONNECT (BY ELECT KICAL CUN I KAC[OR) 2 DISCONNECT AS REQUIRED BY ELECTRICAL CONTRACTOR 3 120V RECEPTACLE REQUIRED FOR PLUG IN CONNECTION BY ELECTRICAL CONTRACTOR 4 120V HARD WIRED CONNECTION BY ELECTRICAL CONTRACTOR 5 150 PSI OPERATING PRESSURE - MOUNT IN CABINET SPACE BELOW SINK. 6 DRAIN PAN TO BE PIPED TO INDIRECT CONNECTION AT FLOOR DRAIN, WALL BOX, MOP SINK, OR AIR GAP FITTING 7 PIPE RELIEF VALVE TO NEAREST FLOOR DRAIN OR HUBDRAIN AT SINK WITH INDIRECT TERMINATION GREASE TRAP SCHEDULE Last Updated: 08/22/16 UNIT TAG LOCATION SERVES BASIS OF DESIGN INSTALLATION TYPE SIZE IN INCHES MAX GPM WEIGHT LBS MATERIAL REMARKS HEIGHT WIDTH DEPTH GT -1 EXPRESSO 3 -COMP BIG DIPPER W -200 -IS FLOOR MT MOTORIZED 16" 24" 26" 20 KS -2 S.S. 1,2,3,4,5,6 HOUZER 1515-6BS 1/2 1/2 2 1.5 - 1 FD -1 FLOOR DRAIN CHROME PLATED, ROUND ADJUSTABLE STRAINER ZURN FD2210-CP - - 2 1 PLUMBING CONTRACTOR TO FIELD VERIFY INLET AND OUTLET INVERTS 2 PROVIDE FLOW RESTRICTION AT SINK DISCHARGE 3 INTERCEPTOR HOUSING WITH ACID RESISTANT INTERIOR COATING 4 CONFIRM WITH LOCAL JURISDICTION THE FINAL RINSE COMPARTMENT CONNECTION (WHETHER TO GREASE TRAP OR FLOOR SINK) PRIOR TO INSTALLATION 5 CONFIRM WITH LOCAL JURISDICTION THE QTY OF SINKS TO GREASE TRAP 6 ELECTRICAL: 115/1 AND 520 WATTS GENERAL ALTERNATE PRODUCTS ACCEPTABLE AS APPROVED BY THE ENGINEER 1 PROVIDE HOUZER STAINIER 190-9180 AND BASKET RB -3100, 1-1/2 17 GA P -TRAP CHROME PLATE, BRASSCRAFT LOOSE -KEY LAV SUPPLY KIT CHROME PLATED WITH BRAIDED FLEXIBLE HOSE. 2 PROVIDE A.R.E. COATING, ANTI -SPLASH BOTTOM DOME STRAINER, GRATING AND DEPTH AS INDICATED ON KITCHEN DRAWINGS OR AS SPECIFIED 3 DISHWASHER PROVIDED BY OTHERS. CONNECT DRAIN TO SINK TAILPIECE WITH DRAIN AND WATER SERVICE & SHUT OFF BY PLUMBING CONTRACTOR. PROVIDE WITH EASTMAN AIRGAP FITTING AT SINK 4 POLYSTYRENE OR METAL BOX WITH QUARTER TURN STOP SHUTOFF. 5 WATER SERVICE & SHUT OFF BY PLUMBING CONTRACTOR �><O I9FiNG-REQ.UII Er) _q T A L�QR-BRAT AIEt=T, L nen -- -t IrkFr-REQt E I-F-X1)15,BIASAS�EXP.� -€ T-ER-BM14I6NO�APPRQVED=EQUAL-- _161m REDUCED PRESSURE ACKFLO PREVENTERS LAST UPDATED: 08122116 UNIT TAG PLUMBING FIXTURE CONNECTION SCHEDULE BASIS OF DESIGN MODEL # OR TYPE LAST UPDATED 9/9/16 SYMBOL DESCRIPTION TYPE MANUFACTURER AND MODEL NUMBER HW CW W GPF/ V GPM REMARKS KS -1 KITCHEN SINK S.S. TRIPLE COMPARTMENT, COUNTERTOP HOUZER PGT -4322 3/4 3/4 2 1.5 - 1 KS -2 HAND SINK S.S. SINGLE COMPARTMENT, COUNTERTOP HOUZER 1515-6BS 1/2 1/2 2 1.5 - 1 FD -1 FLOOR DRAIN CHROME PLATED, ROUND ADJUSTABLE STRAINER ZURN FD2210-CP - - 2 1.5 - TPS -1 TRAP SEAL a SURE SEAL SS2009V - - - - - 6 FS -1 FLOOR SINK RECESSED FLR MT, RD. GRATE, SEEPAGE FLANGE ZURN Z1970-2 - - 3 2 - 2 FCO -1 FLOOR CLEANOUT NICKEL BRONZE TOP, ABS PLUG, ADJUSTABLE JR SMITH 40245 - - DWG - - WCO-1 WALL CLEANOUT CAST IRON TEE, NICKEL BRONZE COVER, ABS PLUG JR SMITH 4530S - - DWG - - DW -1 DISHWASHER UNDERCOUNTER, UNIT BY OTHERS - 1/2 - 1 - - 3 IM -1 ICE MAKER UNIT BY OTHERS GUY GRAY BIM -76 - 1/2 - - - 4 CM -1 COFFEE MAKER UNIT BY OTHERS I - - 1/2 1 - - - 5 GENERAL ALTERNATE PRODUCTS ACCEPTABLE AS APPROVED BY THE ENGINEER 1 PROVIDE HOUZER STAINIER 190-9180 AND BASKET RB -3100, 1-1/2 17 GA P -TRAP CHROME PLATE, BRASSCRAFT LOOSE -KEY LAV SUPPLY KIT CHROME PLATED WITH BRAIDED FLEXIBLE HOSE. 2 PROVIDE A.R.E. COATING, ANTI -SPLASH BOTTOM DOME STRAINER, GRATING AND DEPTH AS INDICATED ON KITCHEN DRAWINGS OR AS SPECIFIED 3 DISHWASHER PROVIDED BY OTHERS. CONNECT DRAIN TO SINK TAILPIECE WITH DRAIN AND WATER SERVICE & SHUT OFF BY PLUMBING CONTRACTOR. PROVIDE WITH EASTMAN AIRGAP FITTING AT SINK 4 POLYSTYRENE OR METAL BOX WITH QUARTER TURN STOP SHUTOFF. 5 WATER SERVICE & SHUT OFF BY PLUMBING CONTRACTOR �><O I9FiNG-REQ.UII Er) _q T A L�QR-BRAT AIEt=T, L nen -- -t IrkFr-REQt E I-F-X1)15,BIASAS�EXP.� -€ T-ER-BM14I6NO�APPRQVED=EQUAL-- _161m REDUCED PRESSURE ACKFLO PREVENTERS LAST UPDATED: 08122116 UNIT TAG LOCATION SERVES BASIS OF DESIGN MODEL # OR TYPE MIN GPM MAX GPM JOINT TYPE IN PSI OUT PSI REMARKS RPBP-1 CABINET EXPRESSO WATTS ES-LF009-3/4" 0.25 13 THIRD 55 40 1 RPBP-2 CABINET ICEMAKER WATTS ES-LF009-12" 1 0.25 1 1 THRD 40 23 1 1 CERTIFIED TO MEET LOW LEAD REQUIREMENTS WITH WETTED SURFACES CONTAINING LESS THAN .25% LEAD TRAP SEAL PRIMERS No form of trap that depends for its seal upon the action of movable parts shall be used. Each fixture trap shall have a liquid seal ... and shall be protected from freezing. Floor drain or similar traps directly connected to the drainage system and subject to infrequent use shall be protected with a trap seal primer. Trap seal primers shall be directly connected to the water supply and shall be accessible for maintenance. (2015 UPC 1005.0, 1006.0 & 1007.0) 2"W UP TO FD 3"W UP 2"V UP TO FS------------� FOR CONTINUATION OF _ _ 2"V UP J"CW LINES, SEE CIVIL — --- ENGINEERING DWGS 2"V UP "CW 3"W 2"W 3"W UP UP TO FS 2"V UP 4"W 3"W UP TO 2"W UP GREASE TRAP TO HAND SINK FOUNDATION PLAN —PLUMBING n; SCALE: 1/2" = 1'-0" RPBP-1 AND RPBP-2 TO DRAIN INDIRECTLY TO FLOOR SINK J"CW DN IN CABINET CO - 3"W DN PBP- FD -1 IN CABINET, PS - SEE DETAIL i2"VTR FS -1 - --- ------------I I GT -1 I -I - -- CED I FS -1 I KS -2 2"V DN i"CW SEE DETAIL �3 I P5..01; DW -1 EWH-1 ET -1 "'HW CONNECTION UNDER COUNTER, FOR DISHWASHER SEE DETAIL /, P2.01' 1ST FLOOR PLAN — PLUMBING SCALE: 1/2" = 1'-0" Building Today, Defining Tomorrow Hermanson Company LLP 1221 2nd Avenue North Kent, Washington 98032 Tel: (206) 575-9700 Fax: (205) 575-9800 www.hermanson.com Contractor Reg J: HERMACLO05BJ TUKWILA CORPORATE OFFICE - COFFEE KIOSK NEIGHBORHOOD FINANCIAL CENTER 12770 GATEWAY DR S TUKWILA, WA 98168 FOR CONTINUATION OF �o�,AODOR�,�� 4"W & 2'V LINES, SEE ��0F WAS,. CIVIL ENGINEERING DWGS 4 Q4 REVIEVVED FOR CODE COMPLIANCE APPROVED . NOV 0 2 20116 I. w ISSUE FOR PE [fife Cif 111 kvv i 1, a DUILDIi` G3 0- fV1SION RECEIVED CITY OF TUKWILA OCT U 7 2016 PERMIT CENTER 3G1A9 O �SS��NAL G�G� 10/05/16 DINN PERMIT CORRECTION 09/12/15 DINN ISSUE FOR PERMIT No. Date By Description Checked DTN Scale AS NOTED Drawing Number C-0195-05582 Project Number 11-15-05682 Issue Date 09/08/15 FOUNDATION, 1ST FLOOR PLANS, SCHEDULE & DETAILS - PLUMBING ........� I THREE COMPARTMENT SINK TO ABOVE FLOOR GREASE TRAP DETAIL P5.01 NOT TO SCALE REVIEWED FOR CODE COMPLIANCE APPROVED NOV 0 2 2016 City of Tukwila BUILDING DIVISION RECEIVED CITY OF TUKWILA OCT U 7 2016 PERMIT CENTER ISSUE FOR PERMIP14!, Building Today, Defining Tomorrow Hermanson Company LLP 1221 2nd Avenue North Kent, Washington 98032 Tel: (206) 575-9700 Fax: (205) 575-9800 www.hermanson.com Contractor Reg #: HERMACLO05BJ TUKWILA CORPORATE OFFICE - COFFEE KIOSK NEIGHBORHOOD FINANCIAL CENTER 12770 GATEWAY DR S TUKWILA, WA 98168 M 36149 1-t6l �A'JUn,�iI3J,�5i: so,.,8 rEt2'man "Y a)gcSifk4 ?Ila+'SLiPi�Si� Revisions J&10/06/16 DWN PERMIT CORRECTION 09/12/16 DWN ISSUE FOR PERMIT No. Date By Description Design Team Design DWN Drawn FVP Checked DTN Scale AS NOTED Drawing Number C-0195-05682 Project Number 11-15-05582 Issue Date 09/08/16 DETAIL SHEET - PLUMBING